Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M18-0019 - TUKWILA SCHOOL DISTRICT / TECHNOLOGY CENTER - DUCT DIFFUSERS AND DUCTLESS A/C UNIT
TSD - TECHNOLOGY CENTER 4060 S 144 ST M18-0019 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.aov MECHANICAL PERMIT 1523049013 Permit Number: M18-0019 4060 S 144TH ST Project Name: TSD - TECHNOLOGY CENTER Issue Date: 2/14/2018 Permit Expires On: 8/13/2018 Owner: Name: TUKIWLA SCHOOL DISTRICT Address: 4640 S 144TH ST, SEATTLE, WA, 98166 Contact Person: Name: DAVID BOAMER Address: 2100 196TH ST SW , LYNNWOOD, WA, 98056 Contractor: Name: D/B SOLUTIONS LLC Address: 2100 196TH ST SW #122, LYNNWOOD, WA, 98036 License No: DBSOLSL934BK Lender: Name: Address: Phone: (425) 744-6500 Phone: (425) 737-4042 Expiration Date: 1/30/2019 DESCRIPTION OF WORK: RELOCATE DUCT DIFFUSERS. INSTALL ONE (1) DUCTLESS AC UNIT FOR IDF CLOSET. Valuation of Work: $22,985.00 Type of Work: NEW Fuel type: ELECT Fees Collected: $519.10 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: 125 Sewer District: VALLEY VIEW Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Date: I I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree t •-.nditions . ached to this permit. Signature: Print Nam Date: Zl I 4 ?)i This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 4: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 8: ***MECHANICAL PERMIT CONDITIONS*** 9: All mechanical work shall be inspected and approved under Permit Center (206/431-3670). 10: Manufacturers installation instructions shall be available on PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 0703 1800 0609 0705 0701 MECH EQUIP EFF MECHANICAL FINAL PIPE/DUCT INSULATION REFRIGERATION EQUIP ROUGH -IN MECHANICAL a separate permit issued by the City of Tukwila the job site at the time of inspection. e CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. Project No. Date Application Accepted: Date Application Expires: MIt" WM (For office use onl MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** King Co Assessor's Tax No.: 1 5-Z 3 O 4 `t d 1 3 Site Address: '4 OL' 0 S 1 41 ST Suite Number: Floor: Tenant Namef 1 $ wt 1..k 54. r4no L 'b.13 i ft t < New Tenant: ❑ Yes ❑..No luhnd�l� J PROPERTY OWNER Name: i'''� ZOe el— l—Address:. Name:. 1y et 1- - SinoL .. ►s Address: 41,4 o s 11411-1" Phone:4 is, 44'(05,OFax: 75 . /749 . 12.14Email: Ci . W 1 t. A State: Woci Zip: 9 e1%Jg CONTACT PERSON - person receiving all project communication Name: i'''� ZOe el— l—Address:. u tb, M E Address: z 1 t:2 O i et L T 4 SI . City:.i 1 Wok,' NL o 0 State: w 4 Zip: 1 ii2123 Phone:4 is, 44'(05,OFax: 75 . /749 . 12.14Email: 1 Y► e....41 0 1 1.41._ 11,4 s h v.1 , 4 et- 1 MECHANICAL CONTRACTOR INFORMATION Company Name: \ u rt 1, s o L b 14-1JjS Address: DI D d 101/.... rlt s r .j w City: Li NAiry t2n A State: we¢ Zip: � 130: Phone:Z5 /`j4 �. 00Fax: 4 L5' 7T/ ,/ ' eca4 ContrReg No.:Dt5oLgLIS1 Xxppate: Tukwila Business License No.: 3,11 S • oei el S g, ci Valuation of project (contractor's bid price): $ 2 Z1 er5 _ Describe the scope of work in detail: RRL ' T E l 4e- 4 .1,..1 -Or 1 ›s i r -L DP-TE."(i } INU e- T t. i S 11 C_ 4 N,• T Use: Residential: Commercial: New ❑ Replacement ❑ New ❑ Replacement ❑ Fuel Type: Electric 14 Gas ❑ Other:_ H:\Applications\Forms-Applications On Line\2016 Applications\Mechanical Permit Application Revised 1-4-16.docx Revised: January 2016 bh -G¢ L Iflg C_LiPSvT— Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Residential, Nighttime Furnace >100k btu 11 Floor furnace 55 dB(A) Suspended/wall/floor mounted heater 57 dB(A) Appliance vent Commercial Repair or addition to heat/refrig/cooling system 47 dB(A) Air handling unit 1 <10,000 cfm 60 dB(A) Unit Type Qty Air handling unit Residential, Nighttime >10,000 cfm 11 Evaporator cooler 55 dB(A) Ventilation fan connected to single duct 57 dB(A) Ventilation system Commercial Hood and duct 47 dB(A) Incinerator — domestic 1 Incinerator — comm/industrial 60 dB(A) Unit Type Qty Fire damper Residential, Nighttime Diffuser 11 Thermostat 55 dB(A) Wood/gas stove 57 dB(A) Emergency generator Commercial Other mechanical equipment 47 dB(A) bW(Tt-ss 4( 1 Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-10PM, Monday through Friday and 8AM-10PM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: • Warning devices; • Construction and property maintenance during the daytime hours (7am-10pm); • Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OW ER OR�li,! ' ZE I�.r NT: Signature: Print Name: , •: V l ?boy �1t IL Mailing Address: Z --10t0 et/..; -11 s►� S� Sw>t r� H:Wpplications\Forms-Applications On Line\2016 Applications\Mechanical Permit Application Revised I-4-16.docx Revised: January 2016 bh Date: Z. 211 `j, Day Telephone: Z j i 44 ' to'S v t� 122-lYNMrvOOt. 1ta3L City State Zip Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID .19 M18-0019 Address: 4060 5 144TH 5 In 152304901 Credit Card Fee Credit Card Fee R000.369.908.00.00 0.00 $15.12 $15.12 MECHANICAL $484.60 PERMIT ISSUANCE BASE FEE PERMIT FEE PLAN CHECK FEE TECHNOLOGY FEE TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R13680 R000.322.100.00.00 R000.322.100.00.00 R000.322.102.00.00 R000.322.900.04.00 0.00 0.00 0.00 0.00 $33.15 $354.53 $96.92 $19.38 $19.38 $519.10 Date Paid: Friday, February 02, 2018 Paid By: DAVID BODMER Pay Method: CREDIT CARD 016130 Printed: Friday, February 02, 2018 12:15 PM 1 of 1 CRWSYSTEMS INSPECTION NO. INSPECTION RECORD Retain a copy with permit 1118-a©f 9 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: --rsD_ leclinology (lam- Type of Inspection: 3 TD �- Address: ya6n 5. 1yy— s+. Date Date Called: Special Instructions: Date Wanted: 3 - 2-2..' 24018 ,--- � n�i. -P.m. Requester: Phone No: ElApproved per applicable codes. Corrections required prior to approval. ThYrrii- EFF 4E- Refri' cleI on curt I L F, neL Inspector: a�/J) Date: 3-23-e3 n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Mk? -da I Project: TsD- Tw1-►I�o loll (-ie r a of Inspection: I-1 e)•) -r41-Al .1-�. 44 Address: V.Date 1/06.0 5 izi 11 s4 Ca d: 3-/ Z z0,8 Special Instructions: Date Wanted: .3 - /7 -2,e)ic a rif p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. Inspector: Date: 3 ...1.1_2‘5,18,,, REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION /1413- L$ 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Project: 73J Ve;///ca l 0.177 Type of Inspection: Mir Docs- iNsoiATioN Address: 4/0W 5) �/ -� /9T 17ri C% Date Called: Special Instructions: Date Wanted: f� Cg --/IP --/C.�% Requester: RCA4 Phone No: 253—.25-2-13-q9 EApproved per applicable codes. Corrections required prior to approval. COMMENTS: 6 j1— Ro t)61. -/A 1 iJe 1 rn SL/ TGc Inspector: xz-s Date: *48 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. HERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M18-0019 DATE: 02/05/18 PROJECT NAME: TSD V TECHNOLOGY CENTER SITE ADDRESS: 4060 S 144TH ST X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: R -j OR/ to \\(ti Building Division Fire Prevention Pllanning Division Public Works ❑ Structural ❑ Permit Coordinator ❑ PRELIMI NARY REVI EW: Not Applicable ❑ (no approval/review required) DATE: 02/06/18 Structural Review Required REVIEWERS INITIALS: DATE: 111 APPROVALS OR CORRECTIONS: DUE DATE: 03/06/18 Approved Corrections Required ❑ Approved with Conditions ❑ ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWERS INITIALS: DATE: Permit Center Gee Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire 0 Ping ❑ PW ❑ Staff Initials: 12/18/2013 DB SOLUTIONS LLC L) Horne Espanol Contact Safety & Health Claims & Insurance 0 Washington State Department of Labor & Industries 0 Search L& A -Z Index Help Page 1 of 2 ARCH Myl&I Workplace Rights Trades & Licensing D/B SOLUTIONS LLC Owner or tradesperson Principals D/B SOLUTIONS, LLC, PARTNER/MEMBER BODMER, DAVID HENRY, PARTNER/MEMBER Doing business as D/B SOLUTIONS LLC WA UBI No. 602 667 064 Parent company D/B SOLUTIONS NORTHWEST, LLC 2100 196TH ST SW, STE 122 LYNNWOOD, WA 98036 425-744-6300 SNOHOMISH County Business type Limited Liability Company Governing persons DAVID H BODMER DAVID HENRY BODMER; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. DBSOLSL934BK Effective — expiration 01/29/2007— 01/30/2019 Bond CBIC Bond account no. SG7910 Active. Meets current requirements. $12,000.00 Received by L&I Effective date 10/05/2009 01/10/2008 Expiration date Until Canceled Insurance Ohio Security Ins Co $1,000,000.00 Policy no. BKS58452938 Received by L&I Effective date 01/10/2018 01/10/2018 Expiration date 01/10/2019 Insurance history Savings Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602667064&LIC=DBSOLSL934BK&SAW= 2/14/2018 DB SOLUTIONS LLC f No savings accounts during the previous 6 • period. Lawsuits against the bond or savings Cause no. 16-2-13886-1 SEA Complaint filed by BOARD OF TRUSTEES OF THE SEATTLE AREA PLUMBING Complaint date 06/22/2016 Open Complaint against bond(s) or savings SG7910 Complaint amount $1,229.36 .r L8I Tax debts .......... No L8,1 tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID 125,919-00 ._............_............... Doing business as D/B SOLUTIONS NORTHWEST LLC Estimated workers reported Quarter 4 of Year 2017 "7 to 10 Workers" L&I account contact T3 / STEPHANIE HENDERSON (360)902-5598 - Email: HSTE235@lni.wa.gov Account is current. Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes ......_..._..._......................_........... No strikes have been issued against this contractor. Contractors not allowed to bid ............................................................... _.................... No debarments have been issued against this contractor. Workplace safety and health No inspections during the previous 6 year period. Page 2 of 2 Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602667064&LIC=DBSOLSL934BK&SAW= 2/14/2018 TUKWILA SCHOOL DISTRICT AUXILIARY PROJECTS PACKAGE #2A TECHNOLOGY & MAINTENANCE SERVICE CENTER ABBREVIATIONS ACT AFF APPROX. ARCH BLDG BLKG BO CJ CL CLR COL CONC CONT D DEMO DTL DIA DIM DN DS DWG E (E), EXIST EJ EL. ELEC ELEV EQ EQUIP FCIO FIN FO FOIC FT FV GA GALV GWB GYP BD H HORIZ HR HT HVAC ID INSUL ACOUSTICAL CEILING TILE ABOVE FINISHED FLOOR APPROXIMATE ARCHITECTURAL BUILDING BLOCKING BOTTOM OF CONTROL JOINT CENTERLINE CLEAR COLUMN CONCRETE CONTINUOUS, CONTINUE DEEP, DEPTH DEMOLISH, DEMOLITION DETAIL DIAMETER DIMENSION DOWN DOWNSPOUT DRAWING EAST EXISTING EXPANSION JOINT ELEVATION ELECTRIC, ELECTRICAL ELEVATION EQUAL EQUIPMENT KIT L MAX MECH MEZZ MFR MIN MISC MTL N NIC NO NTS OC OH OD OPNG OPP ORD PERP PLYWD PL PR PT RD REINF REQD REV FURNISHED BY CONTRACTOR/ RM INSTALLED BY OWNER RO FINISH, FINISHED FACE. OF SHT FURNISHED BY OWNER/ SHTHG INSTALLED BY CONTRACTOR SIM FOOT, FEET SPEC FIELD VERIFY RL GAGE, GAUGE STL GALVANIZED STOR GYPSUM WALL BOARD STRUCT GYPSUM BOARD SUSP HIGH HORIZONTAL HOUR HEIGHT HEATING, VENTILATING, AND AIR CONDITIONING INSIDE DIAMETER INSULATE, INSULATION T&G TG TO TYP UON VERT W WI W/0 WD REFERENCE SYMBOLS BUILDING SECTION INDICATOR SECTION INDICATOR SECTION DETAIL INDICATOR 1 1 - 1 1 ENLARGED DETAIL INDICATOR • I COLUMN GRIDLINE INDICATOR FLAGNOTE KITCHENETTE LONG MAXIMUM MECHANICAL MEZZANINE MANUFACTURE, MANUFACTURE MINIMUM, MINUTE MISCELLANEOUS METAL NORTH NOT IN CONTRACT NUMBER NOT TO SCALE. ON CENTER OVERHEAD OUTSIDE DIAMETER OPENING OPPOSITE OVERFLOW ROOF DRAIN. PERPENDICULAR PLYWOOD PROPERTY LINE. PAIR PAINT, POINT, PRESSURE TREATED. RADIUS, RISER ROOF DRAIN, ROAD REINFORCED, REINFORCING. REQUIRED REVISED, REVISION ROOM ROUGH OPENING SOUTH SHEET SHEATHING SIMILAR. SPECIFICATION SQUARE STAINLESS STEEL. STEEL STORAGE STRUCTURAL SUSPENDED TONGUE AND GROOVE TEMPERED GLASS TOP OF TYPICAL UNLESS OTHERWISE NOTED VERTICAL WEST, WIDE WITH WITHOUT WOOD DRAWING REVISION INDICATOR XX -XX" XXXXXXX ELEVATION INDICATOR DOOR TYPE WINDOW TYPE WALL TYPE GENERAL NOTES 1. NOTHING IN THE DRAWINGS SHALL BE CONSTRUED TO PERMIT AN INSTALLATION IN VIOLATION OF APPLICABLE CODES. ALL WORK PERFORMED UNDER THIS CONTRACT SHALL BE IN FULL ACCORDANCE WITH THE LATEST RULES, REGULATIONS,. RESTRICTIONS, REQUIREMENTS, AND CODES OF THE GOVERNING JURISDICTIONS. 2. THE DRAWINGS ARE. INTENDED TO DESCRIBE THE OVERALL SCOPE OF WORK. CONTRACTORS SHALL FIELD VERIFY EXISTING CONDITIONS AND DIMENSIONS ON THE PROJECT AND ALERT THE ARCHITECT TO ANY CONFLICTS BEFORE BEGINNING WORK. DO NOT SCALE DRAWINGS. THE CONTRACTOR SHALL USE DIMENSIONS SHOWN ON THE DRAWINGS AND ACTUAL FIELD MEASUREMENTS. NOTIFY THE ARCHITECT OF ANY DISCREPANCIES WITH DRAWINGS. 4. CONTRACTOR TO VERIFY ALL DIMENSIONS, PROPERTY LINES, MEASUREMENTS AND CONDITIONS IN THE FIELD BEFORE BEGINNING WORK. ANY DISCREPANCIES, ERRORS OR OMISSIONS TO BE BROUGHT TO THE ATTENTION OF THE ARCHITECT IMMEDIATELY. 5. TYPICAL WALL SECTIONS, FINISHES, AND DETAILS ARE NOT INDICATED EVERYWHERE THEY OCCUR ON PLANS, ELEVATIONS, AND SECTIONS. REFER TO DETAILED DRAWINGS. 6. DETAILED AND/OR LARGER SCALE DRAWINGS TAKE PRECEDENCE OVER GENERAL AND SMALLER SCALE DRAWINGS. 7. PLAN DIMENSIONS SHOWN ARE TO FACE OF FINISH AT EXISTING CONDITIONS AND FACE OF STUD AT NEW CONSTRUCTION, UNLESS NOTED OTHERWISE. 8. UNLESS OTHERWISE NOTED, ALL ANGLES TO BE RIGHT ANGLES, ALL LINES WHICH APPEAR PARALLEL ARE TO BE PARALLEL, AND ALL ITEMS WHICH APPEAR CENTERED ARE TO BE CENTERED. CONTRACTOR TO BE RESPONSIBLE FOR MAINTAINING ALL LINES TRUE, LEVEL, PLUMB, AND SQUARE. CONTRACTOR TO COMPLY WITH CIVIL, LANDSCAPE, STRUCTURAL, MECHANICAL AND ELECTRICAL NOTES. 10. MECHANICAL AND ELECTRICAL SUBCONTRACTORS SHALL OBTAIN ALL REQUIRED PERMITS. 11. THE CONTRACTOR SHALL VERIFY ALL ROUGH -IN DIMENSIONS FOR THE EQUIPMENT. 12. ALL ATTACHMENTS, CONNECTIONS, AND FASTENINGS OF ANY NATURE ARE TO. BE PROPERLY AND PERMANENTLY SECURED IN CONFORMANCE WITH THE BEST PRACTICES OF THE BUILDING INDUSTRY. DRAWINGS SHOW ONLY SPECIAL REQUIREMENTS TO. ASSIST THE CONTRACTOR AND DO NOT SHOW EVERY DETAIL. 13. CAULKING AND SEALANTS. USE PRIMERS AS REQUIRED BY MANUFACTURER. BACKING RODS OR TAPE AS RECOMMENDED BY MANUFACTURER. AND PER SPECIFICATIONS. 14. VAPOR BARRIERS. CONTINUOUS AND APPROVED VAPOR: BARRIERS SHALL BE INSTALLED ON THE HEATED SIDE OF ALL THERMAL INSULATION INSTALLED OR AS INDICATED. SEAL ALL EDGES. 15. CONTRACTOR SHALL VERIFY LOCATION OF ALL EXISTING UTILITIES AND PROTECT AS REQUIRED PRIOR TO COMMENCEMENT OF WORK. 16. CONTRACTOR TO COORDINATE ALL OPERATIONS WITH OWNER, INCLUDING: SITE ACCESS, MATERIALS STORAGE, AND STAGING, INTERRUPTION OF ELECTRICAL AND MECHANICAL SERVICES AND TIMING OF NOISY AND DISRUPTIVE OPERATIONS. CONTRACTOR TO VERIFY SEQUENCE OF WORK. WITH OWNER. 17. CONTRACTOR TO PROTECT EXISTING FURNISHINGS, FIXTURES, EQUIPMENT AND LANDSCAPING FROM DAMAGE. CONTRACTOR TO REPLACE IN KIND ANY SUCH ITEMS DAMAGED. 18. CONTRACTOR SHALL PROTECT ALL ROOF OPENINGS FROM WATER PENETRATION DURING CONSTRUCTION. 19. CONTRACTOR SHALL MAINTAIN CURRENT RECORD DRAWINGS FOR ARCHITECT'S PERIODIC REVIEW. 20. AS BUILT DRAWINGS ARE BASED ON RECORD DRAWINGS AND MAY BE INCLUDED FOR REFERENCE AS TO THE SCOPE OF WORK ONLY. CONTRACTOR SHALL VISIT SITE PRIOR TO BID, EXAMINE EXISTING CONDITIONS AND INCLUDE ALL DEMOLITION REQUIREMENTS FOR THE SCOPE OF THE PROJECT IN THE CONTRACT SUM. NO ADDITIONAL PAYMENTS WILL BE MADE FOR FAILURE TO OBTAIN ALL REQUIRED INFORMATION AND MAKE KNOWN ANY INACCURACIES. 21. THROUGHOUT THE DRAWINGS ARE ABBREVIATIONS THAT ARE IN COMMON USE. THE LIST OF ABBREVIATIONS PROVIDED IS NOT INTENDED TO BE COMPLETE OR REPRESENTATIVE OF CONDITIONS OR MATERIALS USED ON THIS PROJECT. THE ARCHITECT WILL DEFINE THE INTENT OF ANY IN QUESTION. 22. INTERIOR PARTITION TYPES ARE KEYED ON ARCHITECTURAL FLOOR PLANS. SEE PARTITION TYPE FOR DESCRIPTIONS. THE FINISH SCHEDULE AUGMENTS THE PARTITION TYPE DESCRIPTION WITH INFORMATION REGARDING MATERIALS AND FINISHES. 23. THE EXISTING ELEMENTS ARE SHOWN WITH. LIGHT SCREENED LINES, WHILE NEW OR DEMOLISHED ELEMENTS REQUIRED BY THE PROJECT ARE SHOWN WITH DARK LINES. 24. ALL DOOR NUMBERS APPEAR ON THE PLANS EXCEPT WHERE ENLARGED PLANS ARE INDICATED. INDEPENDENT RELITES ARE SHOWN ON INTERIOR ELEVATIONS AND DETAIL KEYS ARE INDICATED THERE. 25. MATERIAL FINISH CODES WHICH IDENTIFY MATERIAL AND FINISHES THROUGHOUT THE DRAWINGS ARE LISTED ON THE FINISH SCHEDULES. THE SPECIFICATIONS SECTIONS WHICH DEFINE THE MATERIALS ARE REFERENCED. FINISH SCHEDULE INDICATES THE VARIOUS FLOOR, WALL AND CEILING FINISHES IN THE INDIVIDUAL ROOMS INDICATED.. REFER TO THE FINISH SCHEDULE NOTES FOR GENERAL FINISH INFORMATION AND WORK. 26. DEFINITIONS OF FINISH CEILINGS ARE SHOWN ON THE REFLECTED CEILING PLAN. MATERIAL, DIMENSIONS OF ELEMENTS WITHIN CEILING, AND SPOT ELEVATIONS OF VARIOUS CEILING PLANES ARE SHOWN. LAYOUTS OF LIGHT FIXTURES, MECHANICAL DIFFUSERS, ETC. IN ROOMS WITHOUT CEILINGS ARE SHOWN FOR DESIGN CLARITY ON REFLECTED CEILING PLANS. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR RESPECTIVE LAYOUTS, COORDINATE AS REQUIRED. 27. LIGHT GAGE METAL FRAMING CLIPS AND CONNECTORS ON SHEET BA9.01: NOTATIONS CALLED OUT BY LETTERS AND NUMBERS REFER TO PRODUCTS MANUFACTURED BY "THE STEEL NETWORK" AS SPECIFIED IN THEIR LATEST CATALOG: ALTERNATE CONNECTORS MANUFACTURED AND TESTED IN ACCORDANCE. WITH ICC-AC261, THAT MEET OR EXCEED THE SPECIFIED CONNECTORS' CAPACITY MAY BE USED SUBJECT TO REVIEW AND APPROVAL BY THE ARCHITECT. MILL CERTIFICATIONS, SUBSTANTIATING TEST DATA, AND LIST STATING THE ITEM -FOR -ITEM SUBSTITUTION AND CAPACITY COMPARISONS MUST BE SUBMITTED TO THE ARCHITECT FOR ANY PROPOSED SUBSTITUTES. INSTALL NUMBER AND SIZE OF FASTENERS AS SPECIFIED BY MANUFACTURER. CONNECTORS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. SITE 0 S 140TH ST S 144TH ST 0) t -co - 5 154TH ST 518 LOCATION MAP SCALE: N.T.S. PROJECT DATA INFORMATION PROJECT DESCRIPTION: TENANT IMPROVEMENTS TO EXISTING 5,451 SF BUILDING (PREVIOUSLY FOSTER LIBRARY) TO CONVERT TO TECHNOLOGY & MAINTENANCE SERVICE. CENTER. ALTERATIONS INCLUDE INTERIOR PARTITION WALLS, DOORS, RELITES, FLOORING, PAINT, SIGNAGE, ASSOCIATED MECHANICAL, ELECTRICAL, TELECOMMUNICATIONS, LIGHTING, AND FIRE ALARM UPGRADES SITE ADDRESS: 4060 S 144TH ST, TUKWILA, WA 98168 ASSESSOR'S PARCEL NO: 1523049013 LEGAL DESCRIPTION: POR S 294.50 FT OF SE QTR OF SW QTR STR 15-23-04 LY ELY OF PLAT OF CHERRY LANE ADDITION LESS N 65 FT OFE120FTTHOF;&LESS E30FTTHOR&S20FT FOR ROADS; & LESS PORTION OF REMAINDER DEEDED TO KING CO FOR ROAD UNDER REC NO 7503240296 & LESS POR FOR RD PER DEED REC# 20151209001191 JURIDICTION: CITY OF TUKWILA APPLICABLE CODES: 2015 INTERNATIONAL BUILDING CODE 2015 INTERNATIONAL MECHANICAL CODE 2015 INTERNATIONAL FIRE CODE 2015 INTERNATIONAL PLUMBING CODE AND ALL RELATED STANDARDS AND STATE. AMENDMENTS 2015 WASHINGTON STATE ENERGY CODE ZONING DESIGNATION: LDR CONSTRUCTION TYPE: V -B OCCUPANCY TYPE: B, OFFICE (NO CHANGE) TOTAL AREA: 5,451SF (NO CHANGE) PROJECT TEAM OWNER TUKWILA SCHOOL DISTRICT 4640 S 144TH STREET TUKWILA, WA 98168 CONTACT: JEFF FEENEY, PROJECT MANAGER TEL: (206) 979 - 9370 ARCHITECT ROLLUDA ARCHITECTS 105 S MAIN ST, SUITE 323 SEATTLE WA, 98104 CONTACT: ALEXANDER CLARK, AIA ALEX.CLARK@ROLLUDAARCHITECTS.COM TEL: (206) 624-4222 FAX: (206) 624-4226 STRUCTURAL REID MIDDLETON 728134TH ST SW, SUITE 200, EVERETT, WA 98204 CONTACT: PAUL CROCKER PCROCKER@REIDMIDDLETON.COM TEL: (425) 741.3800 FAX: (425) 741.3900 MECHANICAL TRES WEST ENGINEERS 2702 S 42ND ST #301, TACOMA, WA 98409 CONTACT: REID HERRON RSH@TRESWEST.COM TEL: (253) 472-3300 FAX: (253) 363-9402 ELECTRICAL TRES WEST ENGINEERS 2702 S 42ND ST #301, TACOMA, WA, 98409 CONTACT: FRED RENO FLR@TRESWEST.COM TEL: (253) 472-3300 FAX: (253) 363-9402 REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Fsvisiorrs will require a new plan submittal and may it 'ude additional plan review fees SEPARATE PERMIT REQUIRED FOR: ❑ Mechanical Lr Electrical 'Plumbing de -as Piping City of Tukwila BuILr '"31 DIVISION DRAWING INDEX TECHNOLOGY & MAINTENANCE SERVICE CENTER GENERAL BG0.01 COVER SHEET BG1.01 CODE. ANALYSIS ARCHITECTURAL BA1.01 SITE PLAN & EXTERIOR ELEVATIONS BAD1.01 DEMO FLOOR & REFLECTED CEILING PLAN BA2.01 BA2.02 BA2.03 BA4.01 BA5.01 BA6.01 BA6.02 BA8.01 BA8.02 BA8.03 BA9.01 BA9.02 FLOOR PLAN & REFLECTED CEILING PLAN FURNITURE & FINISH PLANS ROOF PLAN BUILDING SECTIONS ENLARGED PLANS FINISH SCHEDULES DOOR & WINDOW SCHEDULES INTERIOR ELEVATIONS INTERIOR ELEVATIONS INTERIOR ELEVATIONS DETAILS DETAILS MECHANICAL BM0.0.1 MECHANICAL LEGEND BM0.02 MECHANICAL SCHEDULES BMCF.01 MECHANICAL COMPLIANCE FORMS BMCF.02 MPL MECHANICAL COMPLIANCE CFORMS A BMCF.03 MECHANICAL COMPLIANCE FORMS BM01.01 HVAC DEMOLITION FLOOR PLAN BM1:01 HVAC FLOOR AND CEILING PLANS BM2.01 HVAC ROOF PLAN ELECTRICAL 6E0.01 BE0.02 BED1.01 BE2.01 BE3.01 BE3.02 BE5.01 BE8.01 BE8.02 ELECTRICAL LEGEND AND NOTES WSEC FORM DEMO PLANS ELECTRICAL FLOOR PLAN POWER/LIGHTING FLOOR PLAN SYSTEMS AND MECHANICAL FLOOR PLAN FIRE ALARM POWER ONE -LINE DIAGRAM AND PANEL SCHEDULES FIRE ALARM ONE -LINE DIAGRAM SYSTEMS ONE -LINE DIAGRAM FILE COPY Permit No. VII)/ Pian review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any. adopted code or ordinance. Receipt of approved Field Copy an 2nditions is acknowledged: By: City of Tukwila BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED FEB 0 7 2010 Qty of Tukwila 131J114 11 ( VISION Uu*3a 'trchitects architecture planning inter or design 105 S. Main Street Suite 323 Seattle, VVA 98104 t: 206-624-4222 f: 206-624-4226 6250 VISTERT Alex E.,Rolluda STATE OF WASHINGTON LLI� E2o0 (.0 z rn --e3 (13 047: 0FI-- I Q > w CL5?„ 7- - 0 LLI 0 w �-- < F - Cly REVISION DATE Design: AC Drawn: MM, JL Checked: AC Project. No. 331-16-01 Issuance BID SET Date: 1116/2017 Drawing Title CITY OFT'UgpvE R SHEET FEB 0 PERMIT C 2 2018 ENTER Drawing Number BG0.01 GO.01" TM COV.ER.DWG 1119T2E11T2 19 PM COPYRIGHT.G 2016 ROLLUDA ARCHITECTS INC'. MECHANICAL LEGEND REFERENCE SYMBOLS SL LL G G NEW MECHANICAL WORK ENLARGED PLAN BORDER DETAIL OR DRAWING IDENTIFIER POINT OF CONNECTION PLUMBING DOMESTIC COLD WATER DOMESTIC HOT WATER HOT WATER RECIRC VENT PIPING HVAC PIPING REFRIGERATION PIPING - SUCTION REFRIGERATION PIPING - LIQUID CONDENSATE DRAIN GAS FIRE PROTECTION FM FIRE SPRINKLER MAIN PIPING ELEMENTS DQ BALL VALVE DIRECTION OF FLOW UNION I HOSE BIBB PIPE CONTINUES PIPE CAP 0 PIPE RISING UP PIPE DROPPING DOWN DUCTWORK MANUAL VOLUME DAMPER MOTOR OPERATED DAMPER N RECTANGULAR DUCT UP I\ ! 1/ ti P RECTANGULAR DUCT DOWN ROUND DUCT UP ROUND DUCT DOWN GRD SYMBOLS SUPPLY DIFFUSER RETURN OR RELIEF GRILLE EXHAUST GRILLE CONTROLS CONTROL WIRING ROOM THERMOSTAT/SENSOR MECHANICAL GENERAL NOTES: GENERAL: 1. COORDINATE MECHANICAL WORK WITH ELECTRICAL, ARCHITECTURAL, STRUCTURAL, CIVIL AND LANDSCAPE WORK. PROVIDE ADDITIONAL OFFSETS FOR COORDINATED INSTALLATION WHERE REQUIRED. 2. COORDINATE HVAC, AND PLUMBING WORK PRIOR TO INSTALLATION. DUCTWORK AND EQUIPMENT ACCESS TAKES PRECEDENCE OVER PIPING FOR AVAILABLE SPACE. 3. WHERE USED, THE TERM "PROVIDE" SHALL MEAN "FURNISH AND INSTALL". 4. MAINTAIN A MINIMUM OF 6'-8" CLEARANCE TO UNDERSIDE OF DUCTS, PIPES, CONDUITS, SUSPENDED EQUIPMENT, ETC., IN MECHANICAL ROOM ACCESS SPACES UNLESS OTHERWISE NOTED. 5. COORDINATE EQUIPMENT CONNECTIONS WITH MANUFACTURERS' CERTIFIED DRAWINGS. COORDINATE AND PROVIDE DUCT AND PIPING TRANSITIONS REQUIRED FOR FINAL EQUIPMENT CONNECTIONS TO FURNISHED EQUIPMENT. FIELD VERIFY AND COORDINATE DUCT AND PIPING DIMENSIONS BEFORE FABRICATION. 6. PROVIDE MISCELLANEOUS STEEL. REQUIRED TO ENSURE PROPER INSTALLATION OF MECHANICAL SYSTEMS. 7 LOCATE DAMPERS, CONTROLS AND SIMILAR COMPONENTS SO THAT THEY ARE ACCESSIBLE. PROVIDE ACCESS DOORS FOR MECHANICAL EQUIPMENT INSTALLED BEHIND WALLS, ABOVE INACCESSIBLE CEILINGS AND BELOW FLOORS. COORDINATE ACCESS DOOR LOCATIONS WITH ARCHITECT. 8. COORDINATE ATTACHMENTS TO STRUCTURE TO VERIFY THAT ATTACHMENT POINTS ON EQUIPMENT AND STRUCTURE CAN ACCEPT SEISMIC, WEIGHT, AND OTHER LOADS IMPOSED. 32. 9. MAINTAIN INDICATED FIRE AND SMOKE RATING OF WALLS, PARTITIONS, CEILINGS, AND FLOORS AT MECHANICAL PENETRATIONS. SEAL PENETRATIONS WITH FIRESTOP MATERIAL. PROVIDE MATERIAL IN ACCORDANCE WITH ASTM E 814 AND UL 1479 3M OR APPROVED. 10. LOCATIONS AND SIZES OF FLOOR, WALL, AND ROOF OPENINGS SHALL BE COORDINATED WITH OTHER TRADES INVOLVED. INCLUDE IN THE COST OF MECHANICAL WORK, CUTTING, CORING, PATCHING AND PAINTING OF EXISTING WALLS, CEILINGS, FLOORS AND ROOFS AS REQUIRED TO ACCOMMODATE WORK AS INDICATED IN THE MECHANICAL CONTRACT DOCUMENTS, UNLESS SPECIFICALLY SHOWN ON ARCHITECTURAL DRAWINGS. 11. PROVIDE ELASTOMERIC FOAM MATERIAL ON MECHANICAL EQUIPMENT THAT PRESENT A SAFETY HAZARD. PAINT FOAM MATERIAL WHITE. 12. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFEKEEPING OF HIS OWN PROPERTY ON THE JOB SITE. OWNER ASSUMES NO RESPONSIBILITY FOR PROTECTION OF PROPERTIES AGAINST FIRE, THEFT AND ENVIRONMENTAL CONDITIONS. 13. CLEAN THE JOB SITE DAILY AND REMOVE FROM THE PREMISES ANY DIRT AND DEBRIS CAUSE BY THE PERFORMANCE OF THE WORK INCLUDED IN THIS CONTRACT. BEFORE SUBSTANTIAL COMPLETION, CLEAN EQUIPMENT, FIXTURES, EXPOSED DUCTS, PIPING AND SIMILAR ITEMS. 14. PROVIDE EQUIPMENT THAT FITS INTO THE SPACE ALLOTTED AND ALLOWS ADEQUATE ACCEPTABLE CLEARANCE FOR: INSTALLATION, REPL CEMENT ENTRY,SERVICING AND A MAINTENANCE. COORDINATE WITH OTHER TRADES TO ENSURE NO CONFLICT WITH REQUIRED CLEARANCES. SHALL BE SECURELY FASTENED IN PLACE. 24. ALL EQUIPMENT SHALL BE LABELED PER PLANS & THE REQUIREMENTS OF THE SPECIFICATIONS. 25. RATING OF ACCESS DOORS AND/OR ACCESS PANELS THROUGH FIRE -RATED WALLS, SHAFTS, CEILINGS, ETC., MUST EQUAL THE FIRE RATING OF THE MATERIAL PENETRATED. 26. CAULK & FLASH ALL PENETRATIONS PER CODE 27. ADJUSTING & BALANCING: ADJUST EACH PART OF SYSTEM CONTROLS SHALL CLOSE ALL OSA DAMPERS WHEN TO ENSURE PROPER FUNCTIONING OF ALL CONTROLS. & EQUIPMENT IS NOT RUNNING IN COMPLIANCE WITH SPECIFIED AIR DISTRIBUTION. LEAVE ENTIRE SYSTEM IN C403:2.4:3 OPERATING CONDITION, HVAC/SHEET METAL: 51. PROVIDE VOLUME DAMPERS AT ALL GRILLES, REGISTERS, &DIFFUSERS. 52. MOTORIZED DAMPERS SHALL BE CLASS 1 AND HAVE A MAXIMUM LEAKAGE RATE OF 4 CFM/SQUARE FOOT AT 1.0" W.G. 53. REFERENCE. BUILDING HVAC LOAD CALCULATIONS FOR EQUIPMENT CAPACITIES. NO HUMIDIFICATION PROVIDED. NO SIMULTANEOUS HEATING/COOLING ALLOWED: 28. PROVIDE OPERATING & MAINTENANCE MANUALS (O&MS), RECORD DRAWINGS, & OWNER TRAINING PER WSEC. 29. PROVIDE NATIONAL ELECTRICAL CODE (NEC) MINIMUM WORKING CLEARANCE IN FRONT OF ANY ELECTRICAL PANEL, INCLUDING PANELS ON EQUIPMENT. RE-ROUTE OR OFFSET PIPING AND/OR. DUCTWORK AS REQUIRED. 30. HEAT -TRACED SYSTEMS SHALL MEET THE INSULATION THICKNESS REQUIREMENTS OF THE MANUFACTURERS INSTALLATION INSTRUCTIONS. UNTRACED PIPING WITHIN A HEAT -TRACED SYSTEM SHALL BE INSULATED WITH NOT LESS THAN 1" OF INSULATION. 31. SERVICE WATER PIPING INSULATION CONDUCTIVITY IS NOT TO EXCEED 0.27 BTU PER INCH. INSULATION THICKNESS SHALL BE PER TABLE C403.2.9. PROTECT PIPING INSULATION PER REQUIREMENTS OF WSEC C403.2.9.1 33. PROVIDE COMMISSIONING OF THE HVAC SYSTEM. INCLUDE FUNCTIONAL TESTING SEQUENCE OF OPERATION & TEST PROCEDURES PER WASHINGTON STATE ENERGY CODE. SEE SPECIFICATIONS FOR SPECIFIC EQUIPMENT TESTING REQUIREMENTS. ITEMS TO BE COMMISSIONED, ARE: CONTROL SYSTEMS, AIR HANDLERS, HEAT PUMPS, EXHAUST FANS, PUMPS, AND WATER HEATERS. AIR SYSTEMS SHALL BE BALANCED SO AS TO FIRST MINIMIZE THROTTLING LOSSES, THEN ADJUSTED TO MEET DESIGN FLOW CONDITIONS. PROVIDE PRELIMINARY AND FINAL COMMISSIONING REPORTS. SUBMIT FIGURE C408.1.2.1 COMPLIANCE CHECKLIST FROM WASHINGTON STATE. ENERGY CODE TO AUTHORITY HAVING JURISDICTION UPON COMPLETION OF PRELIMINARY COMMISSIONING REPORT. PROVIDE CLOSEOUT DOCUMENTS IN COMPLIANCE WITH C103.6 34. PROVIDE AIR SYSTEM BALANCING DEVICES, INCLUDING VOLUME DAMPERS, AND ZONE DAMPERS ON TERMINALS AS SHOWN ON PLANS. 35: CEILING FANS, EQUIPMENT, DIFFUSERS, & GRILLES SHALL BE COORDINATED WITH PLACEMENT OF LIGHT FIXTURES. 36, VENTILATION SHALL BE PROVIDED PER IMC CHAPTER 4. MECHANICALLY VENTILATED SYSTEMS SHALL BE CAPABLE OF REDUCING THE OUTDOOR AIR SUPPLY TO THE MINIMUM REQUIRED BY CHAPTER 4 OF THE IMC. 37. OUTSIDE AIR ECONOMIZERS SHALL INCLUDE AUTOMATICALLY MODULATING OUTSIDE & RETURN/RELIEF AIR DAMPERS ARRANGED TO PROVIDE 100% OF THE DESIGN SUPPLY AIR FLOW, & SYSTEM SHALL INCLUDE CONTROLS FOR ECONOMIZER OPERATION. 38. AIR ECONOMIZERS ON SYSTEMS GREATER THAN 65,000 BTUH SHALL PROVIDE PARTIAL COOLING WHEN MECHANICAL COOLING IS REQUIRED TO MEET THE REMAINDER.OF THE COOLING LOAD. 15. BUILDING SPACE IS LIMITED. STRONG ATTENTION TO DETAIL AND CARE MUST BE TAKEN WHEN DEVELOPING SHOP DRAWING SO ROUTING IS COORDINATED WITH OTHER DISCIPLINES. ALL EXPOSEDYSTE S ROUTING M RECUIRES APPROVAL OF ARCHITECT. 16. MECHANICAL EQUIPMENT, PACKAGED UNITS, CONTROL PANELS, MOTOR STARTER, MOTOR CONTROLLERS, VARIABLE FREQUENCY DRIVES AND SIMILAR EQUIPMENT SHALL CARRY A SHORT CIRCUIT CURRENT RATING (SCCR) EQUAL TO OR GREATER THAN AVAILABLE FAULT CURRENT DELIVERED FROM ELECTRICAL SYSTEM. INCLUDE VISIBLE FACTORY NAMEPLATE FOR SUCH EQUIPMENT INDICATING SCCR OF EQUIPMENT IN ACCORDANCE WITH UL. 1995 AND UL 508A.. 39. PROVIDE COMBINATION FIRE & SMOKE DAMPERS (CFSD) AND/OR FIRE DAMPERS WHERE REQUIRED BY CODE. 40. TEMPERATURE CONTROLS SHALL BE MINIMUM OF 7 -DAY PROGRAMMABLE TYPE PROVIDING SETPOINT TEMPERATURES, NIGHT SETBACK, MANUAL OVERRIDE, & DEMOLITION: MINIMUM 5 -DEGREE DEADBAND. CONTROLS SHALL ALLOW 1. TAKE CAUTION IN DEMOLITION OF MECHANICAL EQUIPMENT. FOR OPTIMUM START. 17. STANDARD CURRENT TRADE PRACTICES & METHODS 41. APPLY TO THIS PROJECT. ALL WORK IS TO MEET REQUIREMENTS OF ALL CURRENT CODE & LOCAL 42. JURISDICTIONAL REQUIREMENTS AND AMENDMENTS: THESE CODES INCLUDE BUT ARE NOT LIMITED TO WASHINGTON STATE ENERGY CODE, INTERNATIONAL MECHANICAL CODE, INTERNATIONAL BUILDING CODE, UNIFORM PLUMBING CODE,NEPA, INTERNATIONAL FIRE CODE, & LOCAL JURISDICTIONAL REQUIREMENTS. COMPLY WITH ALL MANUFACTURER'S REQUIREMENTS. COORDINATE WITH OWNER'S REPRESENTATIVE FOR ANY VARIANCES. 18. DRAWINGS ARE DIAGRAMMATIC ONLY & NOT INTENDED TO SHOW ALL DETAILS OF THE WORK. VERIFY LOCATION & MEASUREMENTS OF ALL ITEMS ON THE JOB SITE PRIOR TO INSTALLATION. CONTRACTOR SHALL PROVIDE ALL OFFSETS & ADDITIONAL DUCTWORK & PIPING AS NECESSARY TO AVOID STRUCTURAL ELEMENTS ON THE PROJECT. CONTRACTOR SHALL PRODUCE SHOP DRAWINGS & COORDINATE WITH OTHER TRADES. THERE SHALL BE NO ADDITIONAL COST TO THE .OWNER FOR THIS COORDINATION OR FOR EXTRA MATERIAL REQUIRED IN ORDER TO ACCOMPLISH THIS TASK. 19. PROVIDE COMPLETE & FULLY -OPERATING SYSTEMS. 20. COORDINATE LOCATIONS OF ALL EQUIPMENT & APPURTENANCES WITH OTHER TRADES. 21. ALL EQUIPMENT SHALL BE REGULARLY CATALOGED ITEMS OF THE MANUFACTURER & SHALL BE SUPPLIED AS A COMPLETE UNIT IN ACCORDANCE WITH THE MANUFACTURER'S STANDARD SPECIFICATIONS. ANY OPTIONAL ITEMS REQUIRED FOR PROPER INSTALLATION SHALL BE INCLUDED UNLESS OTHERWISE NOTED. 22. ANY CUTTING, PATCHING & PAINTING OF BUILDING ELEMENTS & FINISHED SURFACES IS TO BE DONE BY THE GENERAL CONTRACTOR. 23. ALL APPLIANCES DESIGNED TO BE FIXED IN POSITION 1. DUCTWORK DIMENSIONS, AS SHOWN ON THE DRAWINGS, ARE INTERNAL CLEAR DIMENSIONS AND DUCT SIZE SHALL BE INCREASED TO COMPENSATE FOR DUCT LINING THICKNESS. 2. PROVIDE TEMPORARY COVERS OVER OPEN ENDS OF EQUIPMENT AND DUCTWORK DURING CONSTRUCTION. 3. PROVIDE MANUAL VOLUME DAMPER FOR EACH DIFFUSER, REGISTER, AND GRILLE. 4 PROVIDE DUCT ACCESS DOORS AT DUCT SMOKE DETECTORS, BACKDRAFT DAMPERS, MOTORIZED CONTROL DAMPERS, FIRE DAMPERS, SMOKE DAMPERS; COMBINATION FIRE/SMOKE DAMPERS, DUCT MOUNTED COILS, DUCT AIRFLOW STATIONS AND LOUVER PLENUMS. 5. PROVIDE THE FOLLOWING MINIMUM BRANCH DUCT SIZE TO DIFFUSERS; REGISTERS, AND GRILLES, UNLESS NOTED TO USE LARGER SIZE ON DRAWINGS: 6"0: 100 CFM 8"0" 200 CFM 10"0: 300 CFM 12"0 450 CFM 14"0: 600 CFM 16`'0: 750 CFM ENERGY CODE: (WASHINGTON STATE ENERGY'CODE) 1, PIPING AND DUCT INSULATION: COMPLY WITH THICKNESS AND TYPES LISTED IN THE WSEC. 2. DUCT SEALING: SEAL DUCT TRANSVERSE JOINTS AND LONGITUDINAL SEAMS PER THE WSEC. 3. RECORD DRAWINGS: PROVIDE PER WSEC. 4. OPERATION AND MAINTENANCE MANUALS: PROVIDE PER WSEC. 5. SYSTEM BALANCING: PROVIDE PER WSEC. EXISTING MECHANICAL: 1. WORK SHALL BE PERFORMED IN A CLEAN AND WORKMANLIKE MANNER. CARE SHALL BE EXERCISED TO MINIMIZE ANY INCONVENIENCE OR DISTURBANCE TO OTHER AREAS OF THE BUILDING WHICH ARE TO REMAIN IN OPERATION. ISOLATE WORK AREAS BY MEANS OF TEMPORARY PARTITIONS AND/OR TARPS TO KEEP DUST AND DIRT WITHIN THE CONSTRUCTION AREA. 2; EXISTING MATERIALS THAT ARE REMOVED SHALL NOT BE REUSED IN NEW SYSTEMS, EXCEPT WHERE INDICATED AS BEING RELOCATED. 3. WHERE INDICATED, DUCTWORK AND PIPING OR PORTIONS OF DUCTWORK AND PIPING SHALL BE REUSED.. REFER TO DRAWING PLANS FOR POINTS OF CONNECTIONS. 4. PROVIDEMPO A Y' TE OR R SUPPORT OF EXISTING MECHANICAL SYSTEMS WHERE REQUIRED BY DEMOLITION OR ALTERATION OF EXISTING STRUCTURE DURING CONSTRUCTION. COORDINATE WITH GENERAL CONTRACTOR AND PROVIDE ALL NECESSARY PIPE, DUCT AND EQUIPMENT SUPPORTS AND HANGERS TO MAINTAIN INTEGRITY, SAFETY AND PROPER OPERATION OF EXISTING MECHANICAL SYSTEMS FOR THE DURATION OF THE WORK. HEAT PUMPS WITH AUXILIARY ELECTRIC HEAT SHALL HAVE CONTROLS COMPLYING WITH WSEC C403.2. SEAL & TEST ALL DUCTWORK AS REQUIRED PER IMC, WSEC C403.2.8.3 LEAKAGE REQUIREMENTS, & IBC VAPOR RETARDER REQUIREMENTS. DUCTWORK DESIGN. PRESSURE IS 2". 43. ALL SHEET METAL DUCTWORK SHALL BE INSULATED IN ACCORDANCE WITH THE WASHINGTON STATE ENERGY CODE. CONCEALED DUCTWORK LOCATED WITHIN THE CONDITIONED SPACE SHALL BE INSULATED WITH A MINIMUM OF R-3.3. DUCTWORK LOCATED IN UNCONDITIONED SPACES SHALL BE INSULATED WITH A MINIMUM OF R-6. WHERE LOCATED OUTSIDE OF THE BUILDING, DUCTWORK SHALL BE INSULATED WITH A MINIMUM OF R-8, 44. SOUND -LINE ALL SUPPLY, RETURN, OR EXHAUST DUCT WITHIN 10' OF FANS UNLESS NOTED OTHERWISE. 45. ALL SHEET METAL PRODUCTS SHALL COMPLY WITH SMACNA DUCT CONSTRUCTION STANDARDS, CURRENT EDITION. 46. ALL RECTANGULAR DUCTWORK SIZES SHOWN ARE GALVANIZED SHEET METAL UNLESS NOTED OTHERWISE. ROUND DUCT SHALL BE SHEET METAL. PROVIDE TURNING VANES IN ALL ROUND 2 -PIECE AND RECTANGULAR 90 DEGREE ELBOWS. 47. ALL DUCT SIZES SHOWN ARE CLEAR INSIDE DIMENSIONS: 48. WHERE FLEXIBLE DUCT IS SHOWN AT GRILLES, REGISTERS, AND DIFFUSERS, PROVIDE 6' MAXIMUM LENGTH OF FLEXIBLE DUCT. 49. PROVIDE FLEXIBLE CONNECTORS AT DUCT CONNECTIONS TO ALL AIR HANDLING EQUIPMENT. 50. SUPPORT FOR SUSPENDED EQUIPMENT SHALL INCLUDE APPURTENANCES AS NOTED IN ASHRAE AND REQUIRED IN CODE FOR SEISMIC/SWAY BRACING. 2. CONTRACTOR SHALL REMOVE ALL PIPING,DUCTWORK, AND EQUIPMENT REQUIRED TO FACILITATE NEW WORK INCLUDING ALL ASSOCIATED INSULATION, HANGERS, VALVES,PLENUM WALLS, DAMPERS, WIREMOLD, WIRING, CONTROLS, AND APPURTENANCES ASSOCIATED WITH EACH PIECE OF EQUIPMENT. WHERE EXISTING ITEMS PENETRATE A WALL OR ROOF, CONTRACTOR SHALL PROVIDE INFILL AT (E) PENETRATIONS THROUGH WALL/ROOF WITH LIKE MATERIALS. PATCH & REPAIR TO MATCH SURROUNDING SURFACES INCLUDING PAINT. 4. CONTRACTOR SHALL PROVIDE TEMPORARY SUPPORT OF EXISTING MECHANICAL EQUIPMENT WHERE REQUIRED BY DEMOLITION OR ALTERATION OF EXISTING STRUCTURE DURING CONSTRUCTION. COORDINATE WITH GC AND PROVIDE NECESSARY SUPPORTS AND HANGERS TO MAINTAIN INTEGRITY, SAFETY: AND PROPER OPERATION OF EXISTING MECHANICAL SYSTEMS. MECHANICAL SHEET LIST: BM0.01 BM0.02 BMCF,01 BMCF.02 BMCF.03 BMD1.01 BM1.01 BM2.01 MECHANICAL LEGEND, GENERAL. NOTES AND SHEET LIST MECHANICAL SCHEDULES MECHANICAL COMPLIANCE FORMS (WA STATE - NREC) MECHANICAL COMPLIANCE FORMS (WA STATE. - NREC) MECHANICAL COMPLIANCE FORMS (WA STATE - NREC) DEMOLITION HVAC FLOOR PLAN HVAC FLOOR & REFLECTED CEILING PLAN HVAC ROOF PLAN EE C CITY OF REVIEWED FOR CODE COMPLIANCE APPROVED FEB 9 7 2010 City of Tukwila ION TUKWIL FEB 0 2 2018 PERMIT CENTER r ilu.*a G r flt c architecture planning interior design 105 S. Main Street Suite 323 Seattle, WA 98104 t: 206-624-4222 f: 206-624-4226 TaES WEST ENGINEERS TRES WEST ENGINEERS, INC.. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com zit C:c (LSI 62 (1 W t0 r o r- L--) W EK 0 Fa"' I r>- W .,✓ ,U O0~ < w X°0ce LU LU 0 IIONIUSECKIM w 0 N CO c0 co 0) H REVISION DATE Design: Drawn: Checked: Project No. RSH MAM RSH 331-16-01 Issuance BID SET Date: 11/6/2017 Drawing Title MECHANICAL LEGEND Drawing Number BM�O1 0.01 - LEGEND.DWG d cp ti cp w COPYRIGHT ©2015 ROLLUDA ARCHITECTS INC 't-. MECHANICAL ABBREVIATIONS 0 DIAMETER, PHASE L LENGTH A AIR LAT LEAVING AIR TEMPERATURE AAV AUTOMATIC AIR VENT LB POUND ABV ABOVE LL REFRIGERANT LIQUID LINE AD AREA DRAIN, ACCESS DOOR LVR LOUVER ADA AMERICANS WITH DISABILITIES ACT LWT LEAVING WATER TEMPERATURE AFF ABOVE FINISHED FLOOR MAT MIXED AIR TEMPERATURE AHJ AUTHORITY HAVING JURISDICTION MAX MAXIMUM AHU AIR HANDLING UNIT MBH THOUSANDS OF BTUH APPROX APPROXIMATE MECH MECHANICAL ARCH ARCHITECT MED MEDIUM AMERICAN SOCIETY OF HEATING, REFRIG. MERV MINIMUM EFFICIENCY REPORTING VALUE ASHRAE AND AIR-CONDITIONING ENGINEERS, INC. MIN MINIMUM B BOILER MISC MISCELLANEOUS BDD BACKDRAFT DAMPER MPG MEDIUM PRESSURE GAS BF BELOW FLOOR MU MAKEUP WATER BFF BELOW FINISHED FLOOR (N) NEW BLDG BUILDING NA NOT APPLICABLE BLW BELOW NEG: NEGATIVE BOD BOTTOM OF DUCT NO NORMALLY OPEN BOP BOTTOM OF PIPE NO. NUMBER BOT BOTTOM NP NON -POTABLE C CONDENSATE PIPING NTS NOT TO SCALE CAP CAPACITY OA OUTSIDE AIR CBV CIRCUIT BALANCING VALVE OAT OUTSIDE AIR TEMPERATURE CD CEILING DIFFUSER OCC OCCUPIED CFM CUBIC FEET PER MINUTE OSA OUTSIDE AIR CL CENTER LINE PD PRESSURE DROP CLO CEILING PERF PERFORATED CO CLEANOUT PH PHASE GOND CONDENSATE PIV POST INDICATOR VALVE CONN CONNECTION POC POINT OF CONNECTION CU CONDENSING UNIT, CUBIC PRESS PRESSURE CV CHECK VALVE, CONSTANT VOLUME PRV PRESSURE REDUCING VALVE CW DOMESTIC COLD WATER PSI POUNDS PER SQUARE INCH DB DRY BULB PU PUMP DEPT DEPARTMENT QTY QUANTITY DF DRINKING FOUNTAIN R REFRIGERANT PIPING DFU DRAINAGE FIXTURE UNIT RA RETURN AIR DIFF DIFFERENTIAL RAF RETURN/RELIEF AIR FAN DIM DIMENSION RAG RETURN AIR GRILLE DN DOWN RCP REFLECTED CEILING PLAN DX DIRECT EXPANSION RD REF ROOF DRAIN REFERENCE, RETURN/EXHAUST FAN DWG DRAWING (E) EXISTING REL RELIEF EA EACH, EXHAUST AIR RET RETURN EAT ENTERING AIR TEMPERATURE: RG RETURN GRILLE ECG EGGCRATE GRILLE RH ROOF HOOD EF EXHAUST FAN RM ROOM EFF EFFICIENCY ROD ROOF OVERFLOW DRAIN EG EXHAUST GRILLE RPBA REDUCED PRESSURE URE BACKFLOW ASSEMBLY ELEC ELECTRIC RPBP REDUCED PRESSURE BACKFLOW PREVENTER ELEV ELEVATION RPM REVOLUTIONS PER MINUTE EMCS ENERGY MANAGEMENT CONTROL SYSTEM RTU ROOFTOP UNIT ENT ENTERING SA SUPPLY AIR ESP EXTERNAL STATIC PRESSURE SAD SUPPLY AIR DIFFUSER EWT ENTERING WATER TEMPERATURE SCH SCHEDULE EX EXHAUST SID SMOKE DAMPER EXT EXTERIOR, EXTERNAL SF SUPPLY FAN, SQUARE FOOT °F DEGREES FAHRENHEIT SG SUPPLY GRILLE FC FLEXIBLE CONNECTOR SL REFRIGERANT SUCTION LINE FCO FLOOR CLEANOUT SMACNA SHEET METAL AND AIR CONDITIONING FD FLOOR DRAIN CONTRACTORS' NATIONAL ASSOCIATION, INC. F/D FIRE DAMPER SP STATIC PRESSURE FLA FULL LOAD AMPS SPEC SPECIFICATION FLR FLOOR SQ SQUARE FLEX FLEXIBLE SUP SUPPLY FPM FEET PER MINUTE TAB TESTING, ADJUSTING AND BALANCING FS FLOOR SINK TEMP TEMPERATURE FISID COMBINATION FIRE SMOKE DAMPER TG TRANSFER GRILLE FOIL FURNISHED BY OWNER, INSTALLED TPRV TEMPERATURE/PRESSURE RELIEF VALVE: BY CONTRACTOR TSP TOTAL STATIC. PRESSURE FV FACE VELOCITY T'STAT THERMOSTAT G GAS TYP TYPICAL GAL GALLON UNOCC UNOCCUPIED GC GENERAL CONTRACTOR V VENT, VOLTS GPM GALLONS PER MINUTE VAV VARIABLE AIR VOLUME UNIT GR GRILLE VD VOLUME DAMPER. GRD GRILLES, REGISTERS, AND DIFFUSERS VEL VELOCITY GWH GAS WATER HEATER. VENT VENTILATION, VENTILATOR HB HOSE BIBB VFD VARIABLE FREQUENCY DRIVE HC HEATING COIL VTR VENT THRU ROOF HD HEAD W WASTE, WATT, WIDTH HOR HORIZONTAL WCO WALL CLEANOUT HP HEAT PUMP, HORSEPOWER W/O WITHOUT HVAC HEATING, VENTILATION & AIR CONDITIONING WPD WATER PRESSURE DROP HW DOMESTIC HOT WATER WSEC WASHINGTON STATE ENERGY CODE HWC DOMESTIC HOT WATER CIRCULATING WSFU WATER SUPPLY FIXTURE UNIT I.E. INVERT ELEVATION WT WEIGHT KW KILOWATT WTD WATER TEMPERATURE DROP MECHANICAL LEGEND REFERENCE SYMBOLS SL LL G G NEW MECHANICAL WORK ENLARGED PLAN BORDER DETAIL OR DRAWING IDENTIFIER POINT OF CONNECTION PLUMBING DOMESTIC COLD WATER DOMESTIC HOT WATER HOT WATER RECIRC VENT PIPING HVAC PIPING REFRIGERATION PIPING - SUCTION REFRIGERATION PIPING - LIQUID CONDENSATE DRAIN GAS FIRE PROTECTION FM FIRE SPRINKLER MAIN PIPING ELEMENTS DQ BALL VALVE DIRECTION OF FLOW UNION I HOSE BIBB PIPE CONTINUES PIPE CAP 0 PIPE RISING UP PIPE DROPPING DOWN DUCTWORK MANUAL VOLUME DAMPER MOTOR OPERATED DAMPER N RECTANGULAR DUCT UP I\ ! 1/ ti P RECTANGULAR DUCT DOWN ROUND DUCT UP ROUND DUCT DOWN GRD SYMBOLS SUPPLY DIFFUSER RETURN OR RELIEF GRILLE EXHAUST GRILLE CONTROLS CONTROL WIRING ROOM THERMOSTAT/SENSOR MECHANICAL GENERAL NOTES: GENERAL: 1. COORDINATE MECHANICAL WORK WITH ELECTRICAL, ARCHITECTURAL, STRUCTURAL, CIVIL AND LANDSCAPE WORK. PROVIDE ADDITIONAL OFFSETS FOR COORDINATED INSTALLATION WHERE REQUIRED. 2. COORDINATE HVAC, AND PLUMBING WORK PRIOR TO INSTALLATION. DUCTWORK AND EQUIPMENT ACCESS TAKES PRECEDENCE OVER PIPING FOR AVAILABLE SPACE. 3. WHERE USED, THE TERM "PROVIDE" SHALL MEAN "FURNISH AND INSTALL". 4. MAINTAIN A MINIMUM OF 6'-8" CLEARANCE TO UNDERSIDE OF DUCTS, PIPES, CONDUITS, SUSPENDED EQUIPMENT, ETC., IN MECHANICAL ROOM ACCESS SPACES UNLESS OTHERWISE NOTED. 5. COORDINATE EQUIPMENT CONNECTIONS WITH MANUFACTURERS' CERTIFIED DRAWINGS. COORDINATE AND PROVIDE DUCT AND PIPING TRANSITIONS REQUIRED FOR FINAL EQUIPMENT CONNECTIONS TO FURNISHED EQUIPMENT. FIELD VERIFY AND COORDINATE DUCT AND PIPING DIMENSIONS BEFORE FABRICATION. 6. PROVIDE MISCELLANEOUS STEEL. REQUIRED TO ENSURE PROPER INSTALLATION OF MECHANICAL SYSTEMS. 7 LOCATE DAMPERS, CONTROLS AND SIMILAR COMPONENTS SO THAT THEY ARE ACCESSIBLE. PROVIDE ACCESS DOORS FOR MECHANICAL EQUIPMENT INSTALLED BEHIND WALLS, ABOVE INACCESSIBLE CEILINGS AND BELOW FLOORS. COORDINATE ACCESS DOOR LOCATIONS WITH ARCHITECT. 8. COORDINATE ATTACHMENTS TO STRUCTURE TO VERIFY THAT ATTACHMENT POINTS ON EQUIPMENT AND STRUCTURE CAN ACCEPT SEISMIC, WEIGHT, AND OTHER LOADS IMPOSED. 32. 9. MAINTAIN INDICATED FIRE AND SMOKE RATING OF WALLS, PARTITIONS, CEILINGS, AND FLOORS AT MECHANICAL PENETRATIONS. SEAL PENETRATIONS WITH FIRESTOP MATERIAL. PROVIDE MATERIAL IN ACCORDANCE WITH ASTM E 814 AND UL 1479 3M OR APPROVED. 10. LOCATIONS AND SIZES OF FLOOR, WALL, AND ROOF OPENINGS SHALL BE COORDINATED WITH OTHER TRADES INVOLVED. INCLUDE IN THE COST OF MECHANICAL WORK, CUTTING, CORING, PATCHING AND PAINTING OF EXISTING WALLS, CEILINGS, FLOORS AND ROOFS AS REQUIRED TO ACCOMMODATE WORK AS INDICATED IN THE MECHANICAL CONTRACT DOCUMENTS, UNLESS SPECIFICALLY SHOWN ON ARCHITECTURAL DRAWINGS. 11. PROVIDE ELASTOMERIC FOAM MATERIAL ON MECHANICAL EQUIPMENT THAT PRESENT A SAFETY HAZARD. PAINT FOAM MATERIAL WHITE. 12. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFEKEEPING OF HIS OWN PROPERTY ON THE JOB SITE. OWNER ASSUMES NO RESPONSIBILITY FOR PROTECTION OF PROPERTIES AGAINST FIRE, THEFT AND ENVIRONMENTAL CONDITIONS. 13. CLEAN THE JOB SITE DAILY AND REMOVE FROM THE PREMISES ANY DIRT AND DEBRIS CAUSE BY THE PERFORMANCE OF THE WORK INCLUDED IN THIS CONTRACT. BEFORE SUBSTANTIAL COMPLETION, CLEAN EQUIPMENT, FIXTURES, EXPOSED DUCTS, PIPING AND SIMILAR ITEMS. 14. PROVIDE EQUIPMENT THAT FITS INTO THE SPACE ALLOTTED AND ALLOWS ADEQUATE ACCEPTABLE CLEARANCE FOR: INSTALLATION, REPL CEMENT ENTRY,SERVICING AND A MAINTENANCE. COORDINATE WITH OTHER TRADES TO ENSURE NO CONFLICT WITH REQUIRED CLEARANCES. SHALL BE SECURELY FASTENED IN PLACE. 24. ALL EQUIPMENT SHALL BE LABELED PER PLANS & THE REQUIREMENTS OF THE SPECIFICATIONS. 25. RATING OF ACCESS DOORS AND/OR ACCESS PANELS THROUGH FIRE -RATED WALLS, SHAFTS, CEILINGS, ETC., MUST EQUAL THE FIRE RATING OF THE MATERIAL PENETRATED. 26. CAULK & FLASH ALL PENETRATIONS PER CODE 27. ADJUSTING & BALANCING: ADJUST EACH PART OF SYSTEM CONTROLS SHALL CLOSE ALL OSA DAMPERS WHEN TO ENSURE PROPER FUNCTIONING OF ALL CONTROLS. & EQUIPMENT IS NOT RUNNING IN COMPLIANCE WITH SPECIFIED AIR DISTRIBUTION. LEAVE ENTIRE SYSTEM IN C403:2.4:3 OPERATING CONDITION, HVAC/SHEET METAL: 51. PROVIDE VOLUME DAMPERS AT ALL GRILLES, REGISTERS, &DIFFUSERS. 52. MOTORIZED DAMPERS SHALL BE CLASS 1 AND HAVE A MAXIMUM LEAKAGE RATE OF 4 CFM/SQUARE FOOT AT 1.0" W.G. 53. REFERENCE. BUILDING HVAC LOAD CALCULATIONS FOR EQUIPMENT CAPACITIES. NO HUMIDIFICATION PROVIDED. NO SIMULTANEOUS HEATING/COOLING ALLOWED: 28. PROVIDE OPERATING & MAINTENANCE MANUALS (O&MS), RECORD DRAWINGS, & OWNER TRAINING PER WSEC. 29. PROVIDE NATIONAL ELECTRICAL CODE (NEC) MINIMUM WORKING CLEARANCE IN FRONT OF ANY ELECTRICAL PANEL, INCLUDING PANELS ON EQUIPMENT. RE-ROUTE OR OFFSET PIPING AND/OR. DUCTWORK AS REQUIRED. 30. HEAT -TRACED SYSTEMS SHALL MEET THE INSULATION THICKNESS REQUIREMENTS OF THE MANUFACTURERS INSTALLATION INSTRUCTIONS. UNTRACED PIPING WITHIN A HEAT -TRACED SYSTEM SHALL BE INSULATED WITH NOT LESS THAN 1" OF INSULATION. 31. SERVICE WATER PIPING INSULATION CONDUCTIVITY IS NOT TO EXCEED 0.27 BTU PER INCH. INSULATION THICKNESS SHALL BE PER TABLE C403.2.9. PROTECT PIPING INSULATION PER REQUIREMENTS OF WSEC C403.2.9.1 33. PROVIDE COMMISSIONING OF THE HVAC SYSTEM. INCLUDE FUNCTIONAL TESTING SEQUENCE OF OPERATION & TEST PROCEDURES PER WASHINGTON STATE ENERGY CODE. SEE SPECIFICATIONS FOR SPECIFIC EQUIPMENT TESTING REQUIREMENTS. ITEMS TO BE COMMISSIONED, ARE: CONTROL SYSTEMS, AIR HANDLERS, HEAT PUMPS, EXHAUST FANS, PUMPS, AND WATER HEATERS. AIR SYSTEMS SHALL BE BALANCED SO AS TO FIRST MINIMIZE THROTTLING LOSSES, THEN ADJUSTED TO MEET DESIGN FLOW CONDITIONS. PROVIDE PRELIMINARY AND FINAL COMMISSIONING REPORTS. SUBMIT FIGURE C408.1.2.1 COMPLIANCE CHECKLIST FROM WASHINGTON STATE. ENERGY CODE TO AUTHORITY HAVING JURISDICTION UPON COMPLETION OF PRELIMINARY COMMISSIONING REPORT. PROVIDE CLOSEOUT DOCUMENTS IN COMPLIANCE WITH C103.6 34. PROVIDE AIR SYSTEM BALANCING DEVICES, INCLUDING VOLUME DAMPERS, AND ZONE DAMPERS ON TERMINALS AS SHOWN ON PLANS. 35: CEILING FANS, EQUIPMENT, DIFFUSERS, & GRILLES SHALL BE COORDINATED WITH PLACEMENT OF LIGHT FIXTURES. 36, VENTILATION SHALL BE PROVIDED PER IMC CHAPTER 4. MECHANICALLY VENTILATED SYSTEMS SHALL BE CAPABLE OF REDUCING THE OUTDOOR AIR SUPPLY TO THE MINIMUM REQUIRED BY CHAPTER 4 OF THE IMC. 37. OUTSIDE AIR ECONOMIZERS SHALL INCLUDE AUTOMATICALLY MODULATING OUTSIDE & RETURN/RELIEF AIR DAMPERS ARRANGED TO PROVIDE 100% OF THE DESIGN SUPPLY AIR FLOW, & SYSTEM SHALL INCLUDE CONTROLS FOR ECONOMIZER OPERATION. 38. AIR ECONOMIZERS ON SYSTEMS GREATER THAN 65,000 BTUH SHALL PROVIDE PARTIAL COOLING WHEN MECHANICAL COOLING IS REQUIRED TO MEET THE REMAINDER.OF THE COOLING LOAD. 15. BUILDING SPACE IS LIMITED. STRONG ATTENTION TO DETAIL AND CARE MUST BE TAKEN WHEN DEVELOPING SHOP DRAWING SO ROUTING IS COORDINATED WITH OTHER DISCIPLINES. ALL EXPOSEDYSTE S ROUTING M RECUIRES APPROVAL OF ARCHITECT. 16. MECHANICAL EQUIPMENT, PACKAGED UNITS, CONTROL PANELS, MOTOR STARTER, MOTOR CONTROLLERS, VARIABLE FREQUENCY DRIVES AND SIMILAR EQUIPMENT SHALL CARRY A SHORT CIRCUIT CURRENT RATING (SCCR) EQUAL TO OR GREATER THAN AVAILABLE FAULT CURRENT DELIVERED FROM ELECTRICAL SYSTEM. INCLUDE VISIBLE FACTORY NAMEPLATE FOR SUCH EQUIPMENT INDICATING SCCR OF EQUIPMENT IN ACCORDANCE WITH UL. 1995 AND UL 508A.. 39. PROVIDE COMBINATION FIRE & SMOKE DAMPERS (CFSD) AND/OR FIRE DAMPERS WHERE REQUIRED BY CODE. 40. TEMPERATURE CONTROLS SHALL BE MINIMUM OF 7 -DAY PROGRAMMABLE TYPE PROVIDING SETPOINT TEMPERATURES, NIGHT SETBACK, MANUAL OVERRIDE, & DEMOLITION: MINIMUM 5 -DEGREE DEADBAND. CONTROLS SHALL ALLOW 1. TAKE CAUTION IN DEMOLITION OF MECHANICAL EQUIPMENT. FOR OPTIMUM START. 17. STANDARD CURRENT TRADE PRACTICES & METHODS 41. APPLY TO THIS PROJECT. ALL WORK IS TO MEET REQUIREMENTS OF ALL CURRENT CODE & LOCAL 42. JURISDICTIONAL REQUIREMENTS AND AMENDMENTS: THESE CODES INCLUDE BUT ARE NOT LIMITED TO WASHINGTON STATE ENERGY CODE, INTERNATIONAL MECHANICAL CODE, INTERNATIONAL BUILDING CODE, UNIFORM PLUMBING CODE,NEPA, INTERNATIONAL FIRE CODE, & LOCAL JURISDICTIONAL REQUIREMENTS. COMPLY WITH ALL MANUFACTURER'S REQUIREMENTS. COORDINATE WITH OWNER'S REPRESENTATIVE FOR ANY VARIANCES. 18. DRAWINGS ARE DIAGRAMMATIC ONLY & NOT INTENDED TO SHOW ALL DETAILS OF THE WORK. VERIFY LOCATION & MEASUREMENTS OF ALL ITEMS ON THE JOB SITE PRIOR TO INSTALLATION. CONTRACTOR SHALL PROVIDE ALL OFFSETS & ADDITIONAL DUCTWORK & PIPING AS NECESSARY TO AVOID STRUCTURAL ELEMENTS ON THE PROJECT. CONTRACTOR SHALL PRODUCE SHOP DRAWINGS & COORDINATE WITH OTHER TRADES. THERE SHALL BE NO ADDITIONAL COST TO THE .OWNER FOR THIS COORDINATION OR FOR EXTRA MATERIAL REQUIRED IN ORDER TO ACCOMPLISH THIS TASK. 19. PROVIDE COMPLETE & FULLY -OPERATING SYSTEMS. 20. COORDINATE LOCATIONS OF ALL EQUIPMENT & APPURTENANCES WITH OTHER TRADES. 21. ALL EQUIPMENT SHALL BE REGULARLY CATALOGED ITEMS OF THE MANUFACTURER & SHALL BE SUPPLIED AS A COMPLETE UNIT IN ACCORDANCE WITH THE MANUFACTURER'S STANDARD SPECIFICATIONS. ANY OPTIONAL ITEMS REQUIRED FOR PROPER INSTALLATION SHALL BE INCLUDED UNLESS OTHERWISE NOTED. 22. ANY CUTTING, PATCHING & PAINTING OF BUILDING ELEMENTS & FINISHED SURFACES IS TO BE DONE BY THE GENERAL CONTRACTOR. 23. ALL APPLIANCES DESIGNED TO BE FIXED IN POSITION 1. DUCTWORK DIMENSIONS, AS SHOWN ON THE DRAWINGS, ARE INTERNAL CLEAR DIMENSIONS AND DUCT SIZE SHALL BE INCREASED TO COMPENSATE FOR DUCT LINING THICKNESS. 2. PROVIDE TEMPORARY COVERS OVER OPEN ENDS OF EQUIPMENT AND DUCTWORK DURING CONSTRUCTION. 3. PROVIDE MANUAL VOLUME DAMPER FOR EACH DIFFUSER, REGISTER, AND GRILLE. 4 PROVIDE DUCT ACCESS DOORS AT DUCT SMOKE DETECTORS, BACKDRAFT DAMPERS, MOTORIZED CONTROL DAMPERS, FIRE DAMPERS, SMOKE DAMPERS; COMBINATION FIRE/SMOKE DAMPERS, DUCT MOUNTED COILS, DUCT AIRFLOW STATIONS AND LOUVER PLENUMS. 5. PROVIDE THE FOLLOWING MINIMUM BRANCH DUCT SIZE TO DIFFUSERS; REGISTERS, AND GRILLES, UNLESS NOTED TO USE LARGER SIZE ON DRAWINGS: 6"0: 100 CFM 8"0" 200 CFM 10"0: 300 CFM 12"0 450 CFM 14"0: 600 CFM 16`'0: 750 CFM ENERGY CODE: (WASHINGTON STATE ENERGY'CODE) 1, PIPING AND DUCT INSULATION: COMPLY WITH THICKNESS AND TYPES LISTED IN THE WSEC. 2. DUCT SEALING: SEAL DUCT TRANSVERSE JOINTS AND LONGITUDINAL SEAMS PER THE WSEC. 3. RECORD DRAWINGS: PROVIDE PER WSEC. 4. OPERATION AND MAINTENANCE MANUALS: PROVIDE PER WSEC. 5. SYSTEM BALANCING: PROVIDE PER WSEC. EXISTING MECHANICAL: 1. WORK SHALL BE PERFORMED IN A CLEAN AND WORKMANLIKE MANNER. CARE SHALL BE EXERCISED TO MINIMIZE ANY INCONVENIENCE OR DISTURBANCE TO OTHER AREAS OF THE BUILDING WHICH ARE TO REMAIN IN OPERATION. ISOLATE WORK AREAS BY MEANS OF TEMPORARY PARTITIONS AND/OR TARPS TO KEEP DUST AND DIRT WITHIN THE CONSTRUCTION AREA. 2; EXISTING MATERIALS THAT ARE REMOVED SHALL NOT BE REUSED IN NEW SYSTEMS, EXCEPT WHERE INDICATED AS BEING RELOCATED. 3. WHERE INDICATED, DUCTWORK AND PIPING OR PORTIONS OF DUCTWORK AND PIPING SHALL BE REUSED.. REFER TO DRAWING PLANS FOR POINTS OF CONNECTIONS. 4. PROVIDEMPO A Y' TE OR R SUPPORT OF EXISTING MECHANICAL SYSTEMS WHERE REQUIRED BY DEMOLITION OR ALTERATION OF EXISTING STRUCTURE DURING CONSTRUCTION. COORDINATE WITH GENERAL CONTRACTOR AND PROVIDE ALL NECESSARY PIPE, DUCT AND EQUIPMENT SUPPORTS AND HANGERS TO MAINTAIN INTEGRITY, SAFETY AND PROPER OPERATION OF EXISTING MECHANICAL SYSTEMS FOR THE DURATION OF THE WORK. HEAT PUMPS WITH AUXILIARY ELECTRIC HEAT SHALL HAVE CONTROLS COMPLYING WITH WSEC C403.2. SEAL & TEST ALL DUCTWORK AS REQUIRED PER IMC, WSEC C403.2.8.3 LEAKAGE REQUIREMENTS, & IBC VAPOR RETARDER REQUIREMENTS. DUCTWORK DESIGN. PRESSURE IS 2". 43. ALL SHEET METAL DUCTWORK SHALL BE INSULATED IN ACCORDANCE WITH THE WASHINGTON STATE ENERGY CODE. CONCEALED DUCTWORK LOCATED WITHIN THE CONDITIONED SPACE SHALL BE INSULATED WITH A MINIMUM OF R-3.3. DUCTWORK LOCATED IN UNCONDITIONED SPACES SHALL BE INSULATED WITH A MINIMUM OF R-6. WHERE LOCATED OUTSIDE OF THE BUILDING, DUCTWORK SHALL BE INSULATED WITH A MINIMUM OF R-8, 44. SOUND -LINE ALL SUPPLY, RETURN, OR EXHAUST DUCT WITHIN 10' OF FANS UNLESS NOTED OTHERWISE. 45. ALL SHEET METAL PRODUCTS SHALL COMPLY WITH SMACNA DUCT CONSTRUCTION STANDARDS, CURRENT EDITION. 46. ALL RECTANGULAR DUCTWORK SIZES SHOWN ARE GALVANIZED SHEET METAL UNLESS NOTED OTHERWISE. ROUND DUCT SHALL BE SHEET METAL. PROVIDE TURNING VANES IN ALL ROUND 2 -PIECE AND RECTANGULAR 90 DEGREE ELBOWS. 47. ALL DUCT SIZES SHOWN ARE CLEAR INSIDE DIMENSIONS: 48. WHERE FLEXIBLE DUCT IS SHOWN AT GRILLES, REGISTERS, AND DIFFUSERS, PROVIDE 6' MAXIMUM LENGTH OF FLEXIBLE DUCT. 49. PROVIDE FLEXIBLE CONNECTORS AT DUCT CONNECTIONS TO ALL AIR HANDLING EQUIPMENT. 50. SUPPORT FOR SUSPENDED EQUIPMENT SHALL INCLUDE APPURTENANCES AS NOTED IN ASHRAE AND REQUIRED IN CODE FOR SEISMIC/SWAY BRACING. 2. CONTRACTOR SHALL REMOVE ALL PIPING,DUCTWORK, AND EQUIPMENT REQUIRED TO FACILITATE NEW WORK INCLUDING ALL ASSOCIATED INSULATION, HANGERS, VALVES,PLENUM WALLS, DAMPERS, WIREMOLD, WIRING, CONTROLS, AND APPURTENANCES ASSOCIATED WITH EACH PIECE OF EQUIPMENT. WHERE EXISTING ITEMS PENETRATE A WALL OR ROOF, CONTRACTOR SHALL PROVIDE INFILL AT (E) PENETRATIONS THROUGH WALL/ROOF WITH LIKE MATERIALS. PATCH & REPAIR TO MATCH SURROUNDING SURFACES INCLUDING PAINT. 4. CONTRACTOR SHALL PROVIDE TEMPORARY SUPPORT OF EXISTING MECHANICAL EQUIPMENT WHERE REQUIRED BY DEMOLITION OR ALTERATION OF EXISTING STRUCTURE DURING CONSTRUCTION. COORDINATE WITH GC AND PROVIDE NECESSARY SUPPORTS AND HANGERS TO MAINTAIN INTEGRITY, SAFETY: AND PROPER OPERATION OF EXISTING MECHANICAL SYSTEMS. MECHANICAL SHEET LIST: BM0.01 BM0.02 BMCF,01 BMCF.02 BMCF.03 BMD1.01 BM1.01 BM2.01 MECHANICAL LEGEND, GENERAL. NOTES AND SHEET LIST MECHANICAL SCHEDULES MECHANICAL COMPLIANCE FORMS (WA STATE - NREC) MECHANICAL COMPLIANCE FORMS (WA STATE. - NREC) MECHANICAL COMPLIANCE FORMS (WA STATE - NREC) DEMOLITION HVAC FLOOR PLAN HVAC FLOOR & REFLECTED CEILING PLAN HVAC ROOF PLAN EE C CITY OF REVIEWED FOR CODE COMPLIANCE APPROVED FEB 9 7 2010 City of Tukwila ION TUKWIL FEB 0 2 2018 PERMIT CENTER r ilu.*a G r flt c architecture planning interior design 105 S. Main Street Suite 323 Seattle, WA 98104 t: 206-624-4222 f: 206-624-4226 TaES WEST ENGINEERS TRES WEST ENGINEERS, INC.. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com zit C:c (LSI 62 (1 W t0 r o r- L--) W EK 0 Fa"' I r>- W .,✓ ,U O0~ < w X°0ce LU LU 0 IIONIUSECKIM w 0 N CO c0 co 0) H REVISION DATE Design: Drawn: Checked: Project No. RSH MAM RSH 331-16-01 Issuance BID SET Date: 11/6/2017 Drawing Title MECHANICAL LEGEND Drawing Number BM�O1 0.01 - LEGEND.DWG d cp ti cp w COPYRIGHT ©2015 ROLLUDA ARCHITECTS INC 't-. ENERGY EFFICIENT ELECTRIC MOTORS MINIMUM NOMINAL FULL -LOAD EFFICIENCY SCHEDULE DUCT LOCATION MINIMUM NOMINAL FULL -LOAD. EFFICIENCIES (%) MOTOR HP OPEN MOTORS ENCLOSED MOTORS DUCT MATERIAL NUMBER POLES 2 4 6 2 4 6 SYNCHRONOUS SPEED (RPM) 3600 1800 1200 3600 1800 1200 1.0 77.0 85.5 82.5 77.0 85.5 82.5 1.5 84.0 86.5 86.5 84.0 86.5 87.5 2.0 85.5 86.5 87.5 85.5 86.5 88.5 3.0 85:5 89,5 88.5 86.5 89.5 89.5 5.0 86.5 89:5 89.5 88.5 89.5 89.5 7,5 88.5 91.0 90.2 89.5 91.7 91.0. NOTES: BE ESTABLISHED IN ACCORDANCE WITH NEMA STANDARD MGI. ELECTRIC MANUFACTURERS ASSOCIATION (NEMA) DESIGN CLASS SMALL AND MEDIUM AC SQUIRREL -CAGE INDUCTION MOTORS: 1. NOMINAL EFFICIENCIES SHALL DESIGNS A AND B ARE NATIONAL DESIGNATIONS FOR FIXED FREQUENCY DUCT CONSTRUCTION. SCHEDULE DUCT LOCATION DUCT TYPE DUCT SERVICE PRESSURE CLASS (IN) MIN SMACNA SEAL CLASS DUCT MATERIAL NOTES UNCONDITIONED SUPPLY CONSTANT VOLUME AIR HANDLING UNITS 2 B GA ELASTOMERIC RETURN AIR HANDLING UNITS 2 B GA FIBERGLASS EXHAUST EXHAUST FANS 2 C GA NOTE 1 CONDITIONED SUPPLY CONSTANT VOLUME AIR HANDLING UNITS 2 C GA OF PIPE INSULATION BY 1/2 INCH WHERE PIPING IS LOCATED OUTDOORS OR OTHERWISE EXPOSED TO AMBIENT AIR. TUBING. JACKET. WEATHERABLE JACKET OR MANUFACTURER RECOMMENDED COATING. RETURN AIR HANDLING UNITS 2 C GA BLADE EXHAUST EXHAUST FANS 2 B GA NOTES: 1. SEE DRAWINGS FOR FACE SIZE (48x24, 24x24 OR 12x12). PROVIDE 24x24 FOR LAY IN CEILINGS, 2. FACE SIZE DETERMINED FROM DUCT INLET SIZE, 3. SEE AIR DEVICE TAG FOR DUCT INLET SIZE. 4. COORDINATE BORDER TYPE (SURFACE MOUNT,: SNAP IN, LAY -IN, SPLINE, DROPPED FACE, AND BEVELED DROP FACE) WITH ARCHITECTURAL REFLECTED CEILING PLANS. NOTES: PIPING SYSTEMS INSULATION SCHEDULE TYPE OF PIPE INSTALLATION LOCATION INSULATION (TYPE) PIPE SIZE (INCHES) INSULATION THICKNESS (INCHES) NOTES COLD PLUMBING PIPING INSIDE BUILDING ENVELOPE FIBERGLASS ALL SIZES 1" THICK NOTE 2 OUTSIDE BUILDING ENVELOPE AND BURIED ELASTOMERIC ALL SIZES MULTIPLE LAYERS FOR 1-1/2" TOTAL THICKNESS NOTES 1, 4 HOT PLUMBING PIPING INSIDE BUILDING ENVELOPE FIBERGLASS 1-1/4 INCH AND SMALLER 1" THICK. RECTANGULAR - EXPOSED 1-1/2 INCH AND LARGER 1-1/2" THICK NOTE 1 OUTSIDE BUILDING ENVELOPE AND BURIED ELASTOMERIC ALL SIZES MULTIPLE LAYERS FOR 2"TOTAL THICKNESS NOTES 1, 4 NOTES: OF PIPE INSULATION BY 1/2 INCH WHERE PIPING IS LOCATED OUTDOORS OR OTHERWISE EXPOSED TO AMBIENT AIR. TUBING. JACKET. WEATHERABLE JACKET OR MANUFACTURER RECOMMENDED COATING. 1. INCREASE THICKNESS 2. INCLUDE POLYETHYLENE 3. INCLUDE MULTI -PLY LAMINATE 4. INCLUDE FACTORY APPLIED DUCT SYSTEMS INSULATION SCHEDULE LOCATION OF DUCT DUCT SYSTEM TYPE DUCT CONFIGURATION INSULATION TYPE MINIMUM R -VALUE, INSULATION THICKNESS NOTES DUCT NOT WITHIN CONDITIONED SPACE SUPPLY, RETURN, EXHAUST MIXED, OUTSIDE, AND. TRANSFER AIR DUCTS RECTANGULAR - EXPOSED RIGID BOARD R-7, 1 LAYER, 2 INCH THICK A RECTANGULAR - CONCEALED DUCT WRAP R-7, 1 LAYER, 3 INCH THICK WHITE ROUND AND OVAL DUCT WRAP R-7, 1 LAYER, 3 INCH THICK NOTE 4 DUCT WITHIN CONDITIONED SPACE SUPPLY, RETURN, EXHAUST GENERATOR EXHAUST, RELIEF AND TRANSFER AIR DUCTS RECTANGULAR - EXPOSED RIGID BOARD R-3..3, 1 INCH THICK ALUMINUM RECTANGULAR - CONCEALED DUCT WRAP R-33, 1 LAYER, 1-1/2 INCH THICK NOTE 3 ROUND AND OVAL DUCT WRAP R-3:3, 1 LAYER, 1-1/2 INCH THICK C NOTES: AND RELIEF AIR DUCTS FROM BUILDING ENVELOPE TO BACKDRAFT/MOTORIZED DAMPER WITH R -VALUE EQUAL TO BUILDING ENVELOPE THICKNESS. 1. INSULATE OUTSIDE, EXHAUST, SHUTOFF DAMPERS OUTSIDE AIR SUPPLY, EXHAUST OPENINGS, RELIEF OUTLETS, STAIRWAY AND SHAFT VENTS AND RETURN OPENINGS USED FOR AIRSIDE ECONOMIZER SHALL BE PROVIDED WITH CLASS I MOTORIZED DAMPERS IN ACCORDANCE. WITH THE WASHINGTON STATE ENERGY CODE C403.2.4.3. CLASS 1 DAMPERS SHALL HAVE A MAXIMUM LEAKAGE RATE OF 4 CFM/SQ.FT. @ 1.0" W.C. SEE DRAWINGS FOR DAMPER LOCATIONS. OUTSIDE AIR INTAKE OPENING LOCATION 1. INTAKE OPENINGS SHALL BE LOCATED A MINIMUM OF 20 FEET FROM LOT LINES OR BUILDING ON THE SAME LOT. WHERE OPENINGS FRONT ON A STREET OR PUBLIC WAY, THE DISTANCE SHALL BE MEASURED TO THE CENTERLINE OF THE STREET OR PUBLIC WAY 2. MECHANICAL AND GRAVITY OUTDOOR AIR INTAKE OPENINGS SHALL BE LOCATED NOT LESS THAN 10 FEET HORIZONTALLY FROM ANY HAZARDOUS OR NOXIOUS CONTAMINANT SOURCE. EXCEPT AS NOTED IN ITEM 3. 3. INTAKE OPENINGS SHALL BE LOCATED NOT LESS THAN 3 FEET BELOW CONTAMINANT SOURCES WHERE SUCH OPENINGS ARE LOCATED WITHIN 10 FEET OF THE OPENING. 4. INTAKE OPENINGS ON STRUCTURES IN FLOOD HAZARD AREAS SHALL BE AT OR ABOVE DESIGN FLOOD LEVEL. 5. ENVIRONMENTAL AIR (RELIEF AIR) SHALL BE A MINIMUM OF 3 FT FROM OPERABLE OPENINGS INTO BUILDING FOR ALL OCCUPANCIES OTHER THAN GROUP U AND 10 FEET FROM MECHANICAL AIR INTAKES. DIFFUSER, REGISTER, AND GRILLE SCHEDULE TAG MANUFACTURER / MODEL TYPE MATERIAL FINISH FACE STYLE FACE SIZE DUCT INLET MOUNTING PATTERN REMARKS A TITUS TMSA-AA SQUARE CEILING DIFFUSER ALUMINUM WHITE - NOTE 1 NOTE 3 NOTE 4 ADJUSTABLE SEE NOTES B TITUS 50F EGGCRATE GRILLE ALUMINUM WHITE - NOTE 2 NOTE 3 NOTE 4 - RETURN, RELIEF AND OR EXHAUST, SEE NOTES. C TITUS 56FL SIDEWALL RETURN GRILLE ALUMINUM WHITE BLADE NOTE 1 NOTE 3 NOTE 4 ADJUSTABLE SINGLE BLADE, 3/4" SPACING, 0° DEFLECTION, SEE NOTES. NOTES: 1. SEE DRAWINGS FOR FACE SIZE (48x24, 24x24 OR 12x12). PROVIDE 24x24 FOR LAY IN CEILINGS, 2. FACE SIZE DETERMINED FROM DUCT INLET SIZE, 3. SEE AIR DEVICE TAG FOR DUCT INLET SIZE. 4. COORDINATE BORDER TYPE (SURFACE MOUNT,: SNAP IN, LAY -IN, SPLINE, DROPPED FACE, AND BEVELED DROP FACE) WITH ARCHITECTURAL REFLECTED CEILING PLANS. SPLIT -SYSTEM AIR -CONDITIONER SCHEDULE TAG AREA MANUFACTURER/ INDOOR FAN PERFORMANCE ELECTRICAL OUTDOOR UNIT DIMENSIONS WEIGHT NOTES SERVED MODEL FLOW VOLTAGE/ TOTAL SENSIBLE SEER COMP FAN MCA MAX VOLTAGE/ INDOOR/ INDOOR/ PHASE CAPACITY CAPACITY /EER FUSE PHASE OUTDOOR OUTDOOR (CFM) (V/0) (HTG/CLG) (HTG/CLG) (AMPS) (AMPS) (AMPS) (AMPS) V/0 (LxWxHT) (LBS) AC-01/CU-01 MDF LG 15180H5V4 399 208/1 38.9/29.5 22.0/18.2 20.5/12.6 14.6 0.25 19 25 208/1 41x10x13/ 34x13x32 40 /145 1, 2, 3 & 4 NOTES: 1) PROVIDE WITH WIRED REMOTE CONTROLLER, INVERTER COMPRESSOR AND LOW AMBIENT COOLING KIT FOR OPERATION DOWN TO 0°F. 2) PROVIDE CONTROUPOWER WIRES AND REFRIGERANT PIPING FROM OUTDOOR UNIT TO INDOOR. UNIT PER MANUFACTURERS RECOMMENDATIONS. 3) UNIT/ASSEMBLY COMPLIES WITH WSEC, SECTION C403.3, ECONOMIZER EXCEPTION 10, OPTION A- 15% HIGHER EFFICIENCY THAN BASELINE. 4) PROVIDE INDOOR UNIT WITH CONDENSATE PUMP OPTION, ROUTE 3/4" CONDENSATE DRAIN UP TO ROOF FOR TERMINATION. SEE SHEET BM2.01. LINED SHEET METAL CAN; INSIDE CLEAR DIMENSION SAME AS DIFFUSER NECK, SEALED TIGHT FINISHED CEILING FINISHED CEILING 1 M0. ! SCALE: NONE COLLAR. FLEXIBLE DUCT CEILING DIFFUSER, REGISTER OR GRILLE NOTE: ONLY USE THIS TYPE OF CONNECTION IN CONSTRICTED CEILING SPACES FLEXIBLE DUCT CEILING DIFFUSER, REGISTER. OR GRILLE NOTE: USE THIS TYPE OF CONNECTION WHERE THERE IS ENOUGH CEILING SPACE TO KEEP KINKS OUT OF FLEXIBLE DUCT SUPPLY/RETURN AIR CONNECTION PIPE INSULATION AND METAL JACKET BIRD SCREEN CLAMP SIZED TO GO AROUND. RIGID INSERT RECTANGULAR TRUNK DUCT CONICAL TAP ROUND TRUNK DUCT CONICAL TAP CONICAL ENTRY TAP SLOPE PIPING; SIZE AND QUANTITY AS NOTED ON PLANS RIGID INSULATION INSERT PER SPECIFICATIONS. PIPE SUPPORT EXISTING ROOF ^43 FRAMING A ROUND BRANCH DUCT VOLUME DAMPER 1 MAIN SUPPLY DUCT 45° ENTRY TAP 1 MAIN SUPPLY DUCT VOLUME DAMPER 45° ENTRY TAP NOTES: 1. FOLLOW SMACNA DUCT CONSTRUCTION STANDARDS. 2. ALL BRANCH DUCTS ARE TO HAVE VOLUME DAMPERS. BRANCH CONNECTION SCALE: NONE SIZE TO PROVIDE 1/2" CLEARANCE ALL. AROUND �--- SHEET METAL CAN PACK WITH FIBERGLASS INSULATION WOOD CURB FLASHING FLASHING MEMBRANE PLATE AND SCREW SEAM CAULK --> RISER CLAMP ROOF CAP - INSULATED PIPING SCALE: NONE 11 1 REVIEWED FOR CODE COMPLIANCE APPROVED FEB 0 7 2018 City of Tukwila I314I4t1 DIVISION RECEIVED CITY OF TUKWILA FEB 0 2 2018 PERMIT CENTER roilus. t to ts architecture planning frit rior d i n 105 S. Main Street Suite 323 Seattle, WA 98104 t: 206-624-4222 f: 206-624-4226 11.1<oz. TRES WEST ENGINEERS TRES WEST ENGINEERS, INC,. 2702 SOUTH 42N0 STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com co to 07; 0 0 0 74 00 I O :=1 I 5 x 0 ft 2 LU W < F- CO g co 0 a < 0) 07 - W I--- I - REVISION DATE Design: Drawn: Checked: Project No. RSH MAM RSH 331-16-01 Issuance BID SET Date: 11/6/2017 Drawing Title MECHANICAL SCHEDULES Drawing Number BM0.02 BN10.01 - LEGEND.DWG C CO COPYRIGHT CEJ 2015 ROLLUDA ARCHITECTS INC v•- REVIEWED FOR CODE COMPLIANCE APPROVED FEB 0 7 2018 City of Tukwila BU..IVISI ON RECEIVED CITY OF TUKWILA FEB 0 2 2018 PERMIT CENTER t a arc Et ; s architecture l r in interior rdesign 105 S. Main Street Suite 323 Seattle, WA 98104 t: 206-624-4222 f: 206-624-4226 TRES WEST ENGINEERS, INC. 2702 SOUTH 421\ID: STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com 0 1-61 o o < 62 - K2) 070 0 15 4--t.t. J W 0tr‘� >-W C �I }--- a: 5 "R" c) o �l D D W W g.c(49 0 co tQ M co CU 0 . e-• O tJ) C3) CO 62 Lu 0 2 d" . 0 I- co 1- i--- REVISION DATE Design: RSH Drawn: MAM Checked: RSH Project No. 331-16-01 Issuance BID SET Date: 11 /6/2017 Drawing Title MECHANICAL COMPLIANCE FORMS Drawing Number BMCF.01 BM0.O1 - LEGEND.DWG COPYRIGHT re 2015 ROLLUDA ARCHITECTS INC t-". Code Compliance Forms forCommercial R2 andState 2015 Washington State Energy o mplR3 over 3 stories and all R1 ' E H -S. Ua Mechanical I, , U,i ..: Summary „r. ,. • t 'a, . .: M ` 20.15 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stones and all R1 Mechanical Summary aryhgMECH .., SU M 2015 Washington Slate Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stones and at R1 Re i sed January 2017 •Project � �;��,a~ nn�,,,,�,ar ummary , ,� � „ � . „ ;, ;�_ <,,,,, .,,; ,: si; 5v PROD -SUM¢ 2015 WSEC Compliance Forms for Commercial Buildings including R2; R3; & R4 over 3 stories and all R1 Revised Jun 2016 GeneralInfa Project Title: Tuk iia Public S o1s aclino!o {& Mainte anteDate s 8' zo1� This PROJ-SUM Project Street Address. 4060 South 144th Streeta For Building Department Use 2015 WashingtonState EnergyCode Compliance Formsfor Commercial Buildings includingR2 & R3 over3"stories and all R1 Revised January 2017 form shall be provided as a cover Pojett City,County, ZiP• Tukwila, King, 98168 Project Information Project Title: Tukwilla Public Schools Technology & Maintenance Date 8/8/2017 Service Water Heating y stems Equipment Type (s) r- Hot water heating tank(s) lest Instantaneous 2 NO service water systems Heatexchan a from space heat boiler or ❑ Dedicated boiler ❑ g p central hot water/steam Distribution Type (s) ❑ Circulation System 0 On -demand. sheet for all compliance form Project Owner or Rep: Tukwila School District Applicant Information. Provide contact information for individual who can res onl to P inquiries about compliance form information provided:. For Building Dept. Use submittals. Project Title matches Jurisdiction: Tukwila School District Company Name: Tukwila School District project. plans title block.S Company Address: 4640 S 144th Street Tukwila, WA 98168 Project Description. Selectall that apply to the scope of project. Select Addition + Existing or Alteration + Existing if the. existingbuilding will be. g combined with the addition or alteration to demonstrate comp!iance per Section C5021 or C503.1, New Construction and Additions ❑ New Building ❑ Building Addition Existing Building Retrofit Alterationthe ❑ ❑ Alteration +.Existing 0 Change of Occupanty ❑ His4oriaBuilding Building Elements Scope - Select all that apply 0 All ❑ Building Envelope ot:Water Systems ❑ Lighting Systems ❑ Service 1-10t ❑ ❑Change ❑ Addition + Existing in Space Conditioning Mechanical Systems m Electrical Systems Applicant Name: Tres West Engineers, Applicant Phone: 253-4724300 Commissioning Commissioning is required fee ❑ Mechanical systems per C408.2 ❑ Service water heating systems per C408,4 If required, commissioning shall be performed for all applicable systems`regardless of individual equipment capacity, Exceptions to commissioning requirements: ❑ I Totatoutput capacity of all mechanical space conditioning: systems in the building do not exceed 240,000 Btu/h cooling or 300,000 Btu/h heating. Mechanical systems commissioning not required. ❑ Capacity of largest service water heating system in building does not exceed 200;000 Btu/h. Service water heating systems commissioning not required. Project Description Briefly describe mechanical systems in text box provided ❑ Total Bldg Performance (TBP) This path includes all mandatorY provisions per C401:2 Option 2. MECH-SUM, MECH=CHK, and C407 Energy Analysis forms required: ❑ New Building Adding a Split System ductwork: with new. 1 Building Addition Q Tenant Improvement Air -Conditioner, Replacing.existing. Transfer Replacing existing diffusers with new. 1 System Retrofit Griles with new. Replacing ■ No System Changes existing Desi Load. Calculations ' 1% Load calculation summary ❑ .MECH-LOAD-CALL Form Provide design load calculations for all mechanical systems and equipment serving the building heating, cooling or ventilating needs: If a load calculation summary is provided with the permit documents that includes al! applicable compliance information then the MECH-LOAD-CALL form is not required. Low Energy and Semi -Heated Spaces (Note 6 and 7) Space T e vp Location` in Plans O S ace s p ()Served Area Served, square feet Heating : Capacity, Btu/h (Note 4) Cooling Capacity, Btu/h (Note 5) Peak Space Conditioning Capacity, Btulh sf Compliance Check Notes Occupancy' Type 0 All CommercialQ Group R'- R2, R3; & R4 � Over 3 stories and all R1 • Mixed Use - Building is greater than three stories above grade and it has both Commercial and Group R occupancies. Mixed Occupancy - Building. is three stories orless above grade and it has both Commerical and Group R2, R3 or R4 occupancies, Select All Commercial to document compliance for the:commercial areas of the building. The residential spaces shall comply with the WSEC Residential Provisions. Mechanical Schedules 4 Mechanical.Plans (TBD) ❑ MECH-EQ Forms indicate location of equipment information. If provided on plans then MECH-EQ forms are not required, however, include on plans all applicable compliance information listed in WECH-EQ tables, Dedicated. Outdoor Air i stem.Re Requirements and y q High Efficiency VAV Alternate fl All not n ❑ DOAS is required per 0403:6 effectiveJuly 1, 2017 (office, retail, education, library and fire station occupancies) occupied, conditioned areas shall beserved by a DOAS that delivers required ventilation air in a manner that does require space conditioning fan operation. Space conditioning fans cycled off when no heating or cooling !s required. provided via naturatventilation per 2015 IMC in lieu of DORS 0403:6 Exception 1 p p { p ) iconditioningvid a H V s stem 4 [� Ventilation. and space provided by E AV y per C 03:7 in lieu of DORS (0403.6; Exception 2) DOAS included in project, although not required (occupancy not office, retail, education, library or fire station) DOAS related allowances included in project; 1 Prescriptive vertical fenestration maximum area allowance increased to 40% per C402.4.1.4 with 100% of conditioned,floorarea in building .served by DOAS. 1 Exception to air economizer per C403.3 Exception 1, include MEC-I-ECONO form. Note 4 - Provide, total installed heating. output capacity of systems serving Low Energy or Semi -Heated space(s) in blah,. Note 5 -Provide-iota! installed coolie ca :cit of system Low s ace s in 8fulh, Not allowed for semi -heated spaces. Enter 0 if no cooling.. g capacity YservingEnergy p (1 p g Note 6 - Refer to Section C402.1.1 Low Ener Building. !Mailed peak space conditioning capacity,.heatin or cooling, may not exceed 3:4 BtultisC 9Y 9 R : P 9g 9. Y . Note7 -Refer to Section 0402:4;1.1 and Semi -Heated Space definition in Chapter/. Total heating output capacity may not exceed 8 Btulh"sf: Only systems without electric resistance heating and ne cooling are eligible for the wall insulation exception under semi -heated. Space Conditioning Select ❑ fVentilation all that apply to the scope. o protectr .. ie i Semi-heatedz Fully Cond honed ❑ Low Energy Space Category3 ■S Refrigerated Warehouse r, Walk-in Cooler/Freezer, Display Refrigerated Display Caset Categories Eligible. tow Energy Spaces ❑ Unconditioned El Low energy heating/cooling capacity ❑ Wireless service ❑ Greenhouse' 0 Equipment building equipmentshelter Fan Power 0 Project includes HVAC air distribution systems•that provide heating and/or cooling !f yes, provide a MECH-FANSYS -SUM form: ❑ For one or more systems, the total fan motor nameplate hp of alt fans ii HVAC system exceeds 5hp. If yes, provide a seperate MECH-FANSYS form.for each HVAC system exceeding the 5`horsepowerthreshold. Refer to Section C403.2.11 and MECH-FANSYS-DOC for requirements'and exceptions. Floor Area and Floors Above Grade Building Gross Conditioned Floor Area Project Gross Conditioned Floor Area Stories 1 5,315 5315.0 General Compliance Path Q Prescriptive 0 Total Building Performance Prescriptive- Projects complying prescriptively shall demonstrate compliance with all applicable mandatory and prescriptve requirements of this code Refer to C401.2,. Item 1 for more information. Compliance forms to include with a Prescriptive submittal: All applicable ENV, LTG, MECH and C406, Total Building Performance -Projects complying via total building performance. (TBP) she include a !lin 115% i C407and compliance summary of7esults from. a whole building energy_modelper Sect on n p with all applicable mandatory provisions in this Code: Refer: to Section C401.2 Item 2 for more information. Compliance forms to include with a TPB.submital: PROD -SUM, C406 -SUM & C406 -DETAIL,. ENV -CHK, LTG - EXT, LTG -CHK,. and;all MECH forms (except MECH-ECONO), HVAC HVAC Hydronic Systems Hydronic chilled water 0 Hydronic heating water 1 Water -loop heat pump 0 N hydronic systems 1 Geothermal C406 Additional Efficiency Options - Mechanical ❑ C406.2 More efficient HVAC equipment and fan systems Requires 90% of heating and cooling capacity to be equipment listed it tables C403:2.3(1)-(9) or air -to -water heat pumps and heat recovery chillers. Al! equipment listed in tables. 0403.2.3(1)-(7) must be more efficient than minimum requirements. All stand alone supply,. return, and exhaust tars over ihp must have FEQ Z 71 and must be selected within 10% of maximum total or static pressure. ❑ 0406.6 Dedicated outdoor air system (DORS). Requires 90% of conditioned floor area to be served bya DOAS per C103.6 that. delivers required ventilation .air in a manner that does not require space conditioning fan operation: 0 C406.7 Reduced energy in service water heating Requires 90% of floor area be in occupancy types listed in 0406.7.7 aid that 60% of annual hot water energy use be provided by heat pump, waste heat recovery.orsolar water -heating systems: :. ., :calPermltFlans 2015 WashingtonState EnergyCgde Compliance Forms forGommerctal, R2 and R3 over 3atones and all R1 -Page 1: of 7Washington , i Checkllst MECH CHK 2015 State Energy Code Com !iance Forms for Commercial R2 and R3 over 3 Stories and all R1 - Page 2 of 7 2015 Washington State Energy Coda Compliance Forms f r Commercial, R2 and R3 over 3 stori nand all R1 - Page 3 of 7 Mechanic I Perm Plans Checklist MECH-CHK HKeca 2015 Washington Energy Compliance lance Forms for Commercial Buildings including R2.& R3 over 3 stories and all R1 Revised Janua 2017 9Y 9 p 9 9 rY I, Mec an�caRermi Plans Checklist 2015 Washington State Ener Code Compliance Forms for Commercial Buildings R2 & R3 over 3 stories and all R1 9 Energy p 9 9 ECHCH4 RevisedJanuar 2017 Y Buildings including 2&'R3 over 3 torics and all R1 Revised Januar 2017 2015 Washington State Energy Code Compliance Forms for Commercial me din R 9 9Y P9 Y Project Title; Tukwilla Public Schools Technology & Maintenance Date 8/8/2017 Project Title: Tukwilla Public SchooisTechnology.& Maintenance Date 8/8/2017 Protect Title: Tukwilla Public Schools Technology & Maintenance Date' 8/8/2017 The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirenents of the Washington Stele Energy Code, Commercial Provisions. The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the.: Washington State Energy Code, Commercial Provisions. The following information is necessary to check`a permit application for compliance' with the .mechanical systems and equipment requirements of the Washington State Energy Code, Commercial Provisions. Applicable (yes,no,na) Code Section Code Provision Information Required - Must be in permit documents Location in Documents Building Department Notes Applicable (yes;no;na) Code Section Code Provision Information Required - Must be in permit documents Location in Documents Building Department Notes Applicable (yes,noma) Code Section Code Provision Information Required -.Must be in permit documents Location in Documents Building Department: Notes Equipment - Sizln Performance and Type 6. VP N A 0403:2.4 3 Stairway and shaft vent dampers Indicate location of stairway and shaft vent dampers on plans: verify dampers are Class 1 motorized; refer to HVAC System Controls for additional requirements NA 0403:2.4:10 040324.11 R2 R3dwelling Group ! g units, Group R2 steeping units For rim conditioning mini 5-2 ramie IthermostatsI o primary space co ditioning syste indicate prog ab e capable oftwo setback periods per day; for ail thermostats indicate purpose (heating only, cooling. only, or both), required temperature range and at minimum a 10°F'deadiand; or exception taken NA 0403.1 Exempt process equipment Identify equipment to be used in manufacturing, industrial orcommercial processes that do not Provide space conditioning; identfY Provisions applicable to this equipment er C403.1 exception NA 0403.2,4:4 Zone isolation dampers For systemsserving areas > 25;000 sf or spanning more than one floor, that irclude areas that are expected to be, occupied non-simultaneously;_identify isolation zone areas an plans and locations of a ssociated.isolation.dampers in HVAC distribution system; refer toHVAC System Controls for additional requirements Indicate method 01 ventilation air deliver natural or mechanical For each zone y ( ) Bell :01 Yes 0403.2:1 Load calculations Prodide load calculation% performed per ASHRAE Std 183 or equivalent, using design parameters per C302 and Appendix C; include load adjustments to account for energy recoveryFor Sea. Attached Yes 6403.2.6 0403.2.11.4 Ventilation9 ° if mechanically delivered, indicate that systems are configured to provide not more. than 150 /° of, but at: least the minimum required volume of outdoor air to each zone per INC,. ASHRAE 62,1 or other applicable code (WAC, OSHA, etc); or exception taken. If delivered via natural ventilation, identify required elements per IMC including minimum openable area to the outdoors or qualifying adjoining spaces BM0.02 NA 0403.2.3:4 Humidification cooling systems with humidification equipment that are also` required to.hate air economizer, indicate humidifier is adiabatic (direct evaporative or fog atomizaton), or exception taken Yes 0403,2:2 Equipment ands stem y sizing Indicate that output capacities: of heating and cooling equipment systems are no greater than the smallest available equipment size that exceeds thecalculated loads; note exceptions taken BM0.02 Additional Must comply Efficiency Package with all 3 Option, More Efficient provisions to be eligible HVAC Equipment & Fan Performance- NA 0403.2:6:2 Demand controlled ventilation Identify spaces > 500 sf with occupant load 25 people/1,000 sf per IMC; for each space indicate whether if is served by an HVAC system with total design OSA> 3,000 elm, and or the system has •airside economizer or antnmahc modulating.OSA damper indicate OSA controls are configured to provide demand controlled.ventilation'orprovide supporting documentation for applied exception Yes C403.2.3 0403.2:3.2 C403.2.13.1 HVAC equipment' performance requirements (efficiency) ( Y) Provide equipmentschedules08 plans or complete .MECH-ED forms indicating type, capacity, rated and WSEC minimum efficiencies for allheating and cooling equipment, include supply and OSA cfms and operating hours for all air systems, identify heating and cooling equipment that not have :corresponding WSEC minimum efficiency (manufacturer rated) BM0.02 NA 0406.2:1 C403.2.3 HVAC selection system9 To comply with additional efficiency package option, calculate the parcentagedf treating and coolin a ul ment in the ro ect based on output ca acit that do not have acorres - ondin q P project ( P P Y) P 9 WSECtisted efficiency; shall be less than 10% to comply NA C406.2.2. 0403.2;3 Minimum equipment efficiency To complywith additional efficiency package option, indicate that all listed heatng and cooling equipment have a rated efficiency that exceeds WSEC listed efficiency by at least 15% NA 0403.2.6.3 Occupancy sensors For ms, classrooms, auditoriums and conference'rooms'> 500 sf; indicate occupancy -based 9Y OSA control when space.is unoccupied and method (closes OSA damper or shuts -off equipment); or alternate means provided to automatically reduce OSA when space is partially occupied Yes. 0405.84 Electric motor efficiency Y List all motors z 1/12 h that are notinte integral a rated piece of equipment) in the mechanical P ( 9 or electrical equipment schedules on plans; indicate hp, rpm; number of poles 'and rated efficiency, cX orexception applied BM0.02„ NA 0406 2,3 0403.2.,11;3 Minimum fanefficiency To comply with additional efficiency package option; indicate rated FEG of steed alone fans is t To ° 71; indicate these fans are sized so the fan efficiency at design conditions is within 10Jo of the maxirnum'total or static efficiencyFor C403.2.14 For fractional hpmotors(1/12 -1 h indicate whether the are an electronically A} y Y motor, have rated efficiency of at least 70 /o or exception taken NA 0403.2.6.4 0403.2.6:4:1 Enclosed loading dock ventilation enclosed loading docks, indicate ventilation / exhaust system method of. activation (gas detection system for CO and NO2; or occupancy sensors), and control method (staged or modulating) Yes 0403.2.11.1 Fan ower limitation P For all HVAC fan systems that provide heating and / or cooling, provide system total nameplate hp in MECH-FANSYS:SUM form For all applicable HVAC Systems with total fan motor h > 5h verifyfans stem motor h or pP y p p' Y P bhp complies with fan power limits perequations In Table C403.2.11.1(1), provide MECH- FANSYS form for each system See' Attached HVAC. System Controls Yes 0403.2:4.1 Thermostatic controls (thermostats and liumidistafs) indicate locations of thermostatic and humidity control devices and the zones hey serve on plans, Including' perimeter system zones Where adjacent (neighboring) zones are controlled by separate therrnostats (including perimeter systems used to offset heat gain or loss), and are connected by permanent openings > 10% of either sf area, indicate controls Configured to preventadjacent zones from operating in conflicting•modes (onetn heat, other in cool); applies. to adjacent perimeter zones, adjacentnonperimeterzones, and adjacentperimeter and nonperirmieter zones If Exception 2 to non ori nete.r zones adjacent perimeter zones, indicate that P P i setpoints and deadband settings in these zones are coordinated so cooling in a nonperimeter zone does not occur until the temperature in that zone is 5°F higher than the aljacent perimeter zone temperature in heating BM1 Al NA 0403.2.6:4 0403.2.6:4.2 Enclosed parking garage ventilation For enclosed parking, garages, indicate ventilation / exhaust system.activated by gas detection system for CO and NO2, and control method (staged or modulating); or exception taken NA 0403.2.7:1. Kitchen exhaust hoods Providecatculations that show a balanced accounting of total :kitchen "exhaust ,(include all ° hoods) with /° of. supply air,: transfer air from adjacent' spaces, and make-up air, if applicable, indicate that direct make-up air to eacKhood does not exceed 10% of hood exhaust For kitchens with total hood exhaust exceeding 2,000 cfm; indicate exhaust air rate per Table. 0403.2:7.1 and compliance method (DCV, energy recovery; or transfer air that would otherwise be exhausted) NA C403.2.11.2 Motor nameplate hp For all applicable HVAC systams:witt3 total fan motor hp >Shp, indicate fan raptors specified are the amallestavailable motor'hp size greater than fan bhp, note exceptions taken NA 0403:2:11.3 Fan efficiency For all applicable HVAC systems with total fanmotorhp .?bhp,: identify in equipment Schedule all fans required to comply with fan efficiency grade and Indicate rated FEG Is 267; or exception taken; indicate these fans are sized so total efficiency is within 15% of the fanapplying maximum'totel:efficiency NA 0403.27:2 Laboratory exhaust systems Refer to Systems Requiring Energy Recovery for requirements NA 0403:2.11.4 Group R occupancy exhaust fan efficacy For all exhaust fans < 400 cfm in Group R:occupancies, indicate in equipment schedulethe fan flow rate and efficacy (cfmlwatt), or exception. taker, refer to Table 0403.2.11.4 (CE -57) NA 0403.2.4.1;1 Heat pump supplementary host Indicate staged heating operation with compression as the first stage ofheating and supplemental heating controlled with outdoor lock -out temperature set to 40°f or less NA 0403.2.13 Variable flow ca pacify- HVAC system fans For HVAG fan motors a 7:5 h indicate method of variable flow control VSD, orequivalent P' ( ° content method ihatreduces design air volume by 50% at 1!3 static design pressure); note exception taken NA 0403.2,13 Variable flow capacity- fans For tan motors z 7.5 hp. indicate method of varia6le'flow control (VSO or equivalent method) in equipment schedule,&exceptiontaken; for equivalent method for an HVAC systemreferto HVACSystem Controls for additional requirements Yes C403.2.4.1.2 Deadband ° •. _ Indicate zone thermostatic controls: configured with 5°F minimum deadband fe systems that control both heating and cooling BM0.01 NA C403.3.1 DX air handler variable cooling control g Under Info rated For DX air handlers with economizer and cooling capacity a 65,000 Btu/h, indicate number of cooling stages provided and :method (multiple compressors and !br variable speed compressors); P essors); indicate minimum displacement (capacity reduction) as %of full load NA 0403.2.4.1.3 Setpoht overlap restriction (thermostats) If separate heating and cooling systems with separate thermostatic control devices are used to serve a zone, indicate locations of both thermostatic control devices and the zone they serve on plans Indicate a limit switch, mechanical stop or DOC control with programming to prevent simultaneous heating and cooling NA 0403.2.3 i cools chiller Maximum air d capacity For chilled waterplants and buildings with > 500 tons of Cooling capaci , indicate air-cooled p 9 9 IY chiller capacity is 5 100 tons, or exception taken ( 9 Economizer) Indicate control method (cooling capacity controlled in response to Space temperature,space temperature controlled by modulating supply airflow, or both) NA 0403:4 Large capacity cooling systems For buildings with ? 300 tons of cooling capacity, indicate method of multi -stage or:variable ° capacity control (VSD, multiple staged compressors, or max capacity of any single unit < 6610 of the total) NA 0403:2.11.5 Fan airflow control For DX air handling units with cooling capacity.? > 65,000 Btu/h and evaporative and chilled water air handling units with fan 0.25 h indicate whether system is sin le zone multiple 9 P•9 P zone and related control method (cooling capacity controlled in response to space temperature, s ace temperature is controlledby modulating supply airflow, or both) For mechanical cooling systems (includes' DX and chilled water coils) that control cooling capacity In response to space temperature - Provide a minimum of two stages, of fan control; indicate minimum fan speed is s 66%of full speed drawings 40°/0 of full peed #an power during periods of low cooling or ventilation only For other mechanical cooling systems (Includes OX:and.chilled water coils}that control space temperature by modulating airflow (in lieu of, or in addition to, controlling capacity. in response to space temperature) - Provide,fan controls for modulating supply airflow; indicate. minimum ° fans speed is 550% of fulls speed drawing 5 301° of fulls speed fan ower during P P 9 p p g periods of low cooling or ventilation.only; or exception taken Yes 0403.2.4.2 C403.2.4,2:1 0403.2.4:2.2 Automatic setback and shutdown Indicate zone thermostatic controls configured with required automatic setbaci and manual override functions, setback temperatures, and control method (automatic timeclock or programmable controls); note exceptions taken BM0.01 NA 0403.2:3.1 Non-standard water-cooled centrifugal chillers For water-cooled centrifugal chillers not designed o oration at standard conditions, provide 9 9 P p calculations documenting' maximum full load and part load rated equipment performance Yes C403.2.4.2.3 Automatic (optimum) start (p ) indicate system controls that adjust equipmentstarttime required to bring cam area served up to design temperature just W scheduled occupancy BM0.01 NA 0403.2:13.1 0403.4.3:2 Centrifugal fano en -circuit 9 p cooling towers: For open -circuit centrifugal fan cooling towers with a 1,100 gpm capacity, indicate cooling P 9 towers comply with efficiency requirements for axial fan open circuit cooling towers NA 0403.2.4;3 Outdoor supply air dampers Indicate automatic controls configured lactose' OSA damper during unoccupied equipment operation; not including economizercooling, night flush or IMO required OSA/exhaust NA C403.4.2 0403.4;2.5 Large capacity systems Forsingle boilers with > 500,000 Bluth capacityAndicate multi -stage or modulating burner For boiler system (single or multiple) with >.1,000;000 Btu/h capacity, indicate. turndown ratio per Table 0403.4.2:5 and melhod(multiple single input boilers, modulating boilers, or combination) NA C403.2.4.3 Stairway shaft vent dampers Indicate method of activation of stairway and shaft vent dampers (fire alarm orintenuption of power) 0403;2.4:4 Zone isolation controls For systemsserving areas 25,000 sf or spanning more than one floor, that include areas that indicat controls that allow for independent are expected to be occupied non -simultaneously; e. a nd pendent space conditioning of isolation zones; or exception taken NA 0403:2:13 Variable flow capacity - pumps For um motors ? 7.5 hp, indicate method of variable flow control (VSD or equivalent method} pumpNA in equipment schedule, orexception taken; for equivalent method for a hydropic system refer to Hydronic System Controls for additional requirements NA 0403.2.12 Meeting outside a building Indicate occupancysensing ar tinier switch controls configured to autematicall/ shut off heating system when area served is unoccupied NA 0403:2.4:12 DOC system capabilities Provide 'central and zone levet DDC controls as required based on system a plication, q Y p capacity or sizethresholds and other qual'fcation per Table CA03.2.4;12:1 Identify all DDC system Input / output control points; Indicate capability for trending and graphical display NA C403.2.3 Gas and oil -fired forced air fumace and unit heaters For Forced air furnaces with capacity a+225,OD0 Bluth and all unit treaters, indicate in P Y equipment schedule intermittent Ignition or:110, flue or draft damper, and rated Jacket loss NA 0403:2.4;5 Snowmalis stems Y Indicate automatic controls configured to shut off system when pavement temperature exceeds 50°F and no precipitation Is falling, and when outdoor air temperature exceeds 40°F NA 0403.2.4.8 Combustion heating equipment For combustion heating equipment with output capacity> 225,000 Btu/h, indicate modulating or staged combustion control Ducting Systems Yes 0403;2.3:3 Packaged electric heating / cooling equipment Verify. all packaged electric equipment with > 6,000 Btulh cooling capacity and any amount of heating is a heat pump; include in equipment schedules BM0.02 NA 0403,2:4,8 Freeze protection system controls Indicate automatic controls to shut off system when outdoor temperature: exceeds 40°F, or conditions protect fluid from freezing Yes 0403 2:8 1 0403.2.8.3 Duct construction Indicate on plans that all ductwork Is constructed and sealed per IMC For OSA ductwork also indicate on plans that ductwork meets alrleaka ere uirements per p 9 q R. •, : retarder 0402,5 and vaporrelarder requirements per the IBC: BM0.01 NA 0403.2.42 . Heating outside a building Indicate systems providing heating in non -enclosed outdoor occupied spaces are radiant systems; refer to HVAC. System Controls for additional requirements NA 0403.2.4;9 Group. R1 hotel./motel guest: rooms For hotels and motels with over 50 guest rooms indicate automatic controleservin guest 9 9 9 rooms that are capable of setback (heating) and set-up' (cooling) of temperature setpoint by at least 5°F; indicate control method - activated by room entry or occupancy sensor NA 0403:2.7.1 Kitchen exhaust Indicate on plans they e, du and exhaust air: rate of each kitchen hood, refer: to HVAC type, LY System Controls for additional requirements .Yes C403.2.8.3 Duct pressure classifications Identify location of low, medium and high pressure ductworteonplans BM0:01 NA 0403:2.4.3 Outdoor supply air, exhaust and relief dampers Indicate locations of OSA intake, and exhaust and reliefoutlet dampers on plans; indicate Whether dampers are Class 1 motorized, or gravity and exception taken (include leakage rutin g, cfm/sf); refer to HVAC System Controls for additional requirements for OSA dampers NA C4032.8.3.3 High pressure. duct leakage test test Indicate high pressure duct leakage testing requirements on plans; provide testresults to jurisdiction when completed 11 I ty f NA 0403:2:4:3 Return air dampers Indicate Locations of return air dampers that are integral to economizer operation; verify' dampers are motorized•indicate whether dampers are Class 1, or within packaged equipment eligible for leakage rating exception (include:leakage rating, cfm/sf) REVIEWED FOR CODE COMPLIANCE APPROVED FEB 0 7 2018 City of Tukwila BU..IVISI ON RECEIVED CITY OF TUKWILA FEB 0 2 2018 PERMIT CENTER t a arc Et ; s architecture l r in interior rdesign 105 S. Main Street Suite 323 Seattle, WA 98104 t: 206-624-4222 f: 206-624-4226 TRES WEST ENGINEERS, INC. 2702 SOUTH 421\ID: STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com 0 1-61 o o < 62 - K2) 070 0 15 4--t.t. J W 0tr‘� >-W C �I }--- a: 5 "R" c) o �l D D W W g.c(49 0 co tQ M co CU 0 . e-• O tJ) C3) CO 62 Lu 0 2 d" . 0 I- co 1- i--- REVISION DATE Design: RSH Drawn: MAM Checked: RSH Project No. 331-16-01 Issuance BID SET Date: 11 /6/2017 Drawing Title MECHANICAL COMPLIANCE FORMS Drawing Number BMCF.01 BM0.O1 - LEGEND.DWG COPYRIGHT re 2015 ROLLUDA ARCHITECTS INC t-". COPYRIGHT (0 2015 Rot.LuDA ARCHITECTS INC BM0.01 - LEGEND.DWG 2 REVIEWED 1 CODE COMPLIANCE APPROVED FEB 0 MY Of ,:-. _..:2- 13 '-:7C CITY OF FEB PERMIT FOR 7 2018 Tukwila ON - -. - F 1 V E D TUKWILA 0 2 2018 CENTER . r' architecture 105 Seattle, 't: 206-624-4222 .f: 206-6244226 liu arc., planning interior S. Main Street Suite 323 WA 98104 , de s n 2015 Washington State Energy Code COMplianCe.Fonns for Commercial, R2 and R3 over 3 Stories and all R1. Page line6irbinic ' I Perrnit Plans' Checklist .. .. , 2015 Washington State Energy Code Compliance Forms for Commercial.Buildings including R28, R3 over.3 stories and all R1 4 of 7 MECH-CHK 2015 Washington State Energy Mechanical Permit Plans Checklist 2015 Washington State Energy Code Compliance Fomis Code Compliance Forms fOr.COMMerCial, R2 and R3 Over -3 stories and all F21 - Page 5 'of 7' , MECH-CHK • 2015 Washington State Energy Code Compliance for ComMercial, R2 and R3. over 3 Stories and all R1 - Page 6 of 7 . , .,. ... Mechanical Permit Plans Checklist MECH-CHK •, Revised January 2017 for Commercial Buildings including R2 8, R3 over 3 stories and all RI Revised January 2017 , . , 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over .3 stories and all R1 Revlsectjanuary 2017 Project Title: Tukwille Public Schools Technology8, Maintenance Date 8/8/2017 Project Title: Tukwilla Public Schools Technology .& Maintenance Dale 8 / 8/ 2017 Project Title: TukwIlla Public Schools Technology & Maintenance Date 8/8/2017 The following information is necessary to check a permit applicationfor compliance with the mechanicalsystemsand equipment 'requirements of the Washington State Energy Code, Commercial Provisions. ' The following information is necessary to check a permit application for compliance with the mechanical systems and equipment roquirements of the Washington State Energy Cede, 'Commercial Previsions. The following information is necessary to check a permit application' for compliance with the mechanical systems and equipment requirements of the Waehington State Energy Code, Commercial Provislona. Applicable (yes,no,na) Code Section Code Provision Information Required.- Must be in permit documents Location in Documents Building Department Mtes Applicable (yes,nomay . Code Section Code Provision Information Required - Must be id permit.documen:s. Location in Documents Building Department Notes (Ayepspinicaa.tanl:) Code Section Code Provision InforMation Required - Must be in permit documents Locafion.in Documents Building Department. Notes Yes C403.2.8.1 C403.2.8.2 Duct insulation For supply and return ductwork located in unconditioned space or outdoors, indicate R -value of inselation on ductwork on plans; identify crimate zone; not exceptions taken For supply ductwork located In conditioned space, identify ff design supply temperature Is < 55*F or >105°F and indicate R -value of insulation on this ductwork on plans; note exception taken For OSA ductwork, shafts and plenums, indicate R -value of insulation on these elements on plans per Table C402.13'for stool framed wells note exception taken BM0.01 BM0.01 NA C403.53 Energy recovery - • • cooler / freezer condensers For buildings with food service, meat or deli departments that have a 580,000 Btu/h of remote: refrigeration capacity for coolers / freezers, indicate condensefER•and cse of captured energy (service water heating, space heating, or dehumidification reheating) For buildings with a 40,000'sf conditioned floor area and with a 1,000,00) Litu/h of remote refrigeration capacity for coolers / freezers indicate condenser ER and to of captured energy for service water heating and also for spade heating, or dehumidification reheating NA C402A.1.4 C403.6 Increased prescriptiVe maximum vertical fenestration area with DOAS Indicate that ell occupied, conditioned spaces are served by a DOAS per C403.6 ' Vy itiztkii, e, , 7. aja 40, 43283 t3.0 (71STVi".$ ONAIA il/o3/1 7 Additional Efficiency Package Option, Dedicated Outside Air Systems (DOAS) NA C406.6 Building provided with DOAS To comply with additional efficiency package option, indicate that 90°A er more of all °copied, conditioned spaces are served by a DOAS per C403.6 Piping Systems multiple Zone Air Systems Yes C403.2.9 Piping insulation Inclicate.design temperature range of fluid conveyed in piping and thickness of insulation (in inches) on hydronic piping plans; or exception taken ' BM0.02 NA C403.5.4 • Energy recovery - condenser systems For buildings with 24-houeoperation and with.> 1,500,000 Btu/h of heat rejection capacity' and design service hot water load > 250,000.Btu/h, irlditate condenser ER:to pre -heat service water; or exception•taken. Provide calculations showing the amount of recovered heat that is utilized (60% of peak heat rejection load or pre-heatservice water to 857). NA C403A A Air systems serving multiple zones Identify suppIy air systems serving multiple zones and the.zones the.y serve on plan% indicate whether system is VAV and rnethod of primary air control or provide supporting documentation for applied exception to VAV C4032.9.1 Piping insulation exposed to weather Indicate:method of protection of pipe insulatien from damage / degradation on hydronic piping plans Economizers Hydronic System Controls NA C403A.4 VAV systems serving multiple zones Provide equipment:schedules. on plans or MECH-EQ form that list all VAV air terminal* and tYPes For each air terminal include: maximum airflow rates for primary supply air during zone peak heating and zone peak cooling; maximum airflow during reheating, recooling or mixing; minimum airflow rate te maintain required ventilation, and the basis for these values; if NC or ASI-IRAE.62.1 multiple ZOne equation is basis for minimum flow rates, provide calculation on plans NA C403.2.13 C403A.2.7 Variable flow control - hydronic system pumps For hydronic system pump motors a 7.5 hp, indicate method of variable flow control (VSD Or equivalent method that requires 5 30design wattage % ttage at 50% design fluid fie*) ; note exception taken Yes C403.3 Air economizer required Identify in equipment schedules -on plans or in MECH-EQ forms all cooling systems requiting air economizer controls Provide MECH-ECONO form' indicating systems utilizing air economizer exceptions, including those with water -side economizer in lieu of alr eeonornizer, Indicate on plans eligible exception(s) taken and measures to comply with exception(s) BM0.02 Identify whether hydronic coils have D.DC controls arid associated newer of pump speed control (differential pressure, zone hYdronic demand, etc) NA C403.2.5 04034.2A Hydroniq system setback- and part load controls For boilers that provide building heating, indicate controls that provide heating water temperature setback -based on outdoor temperature For heating and 'chilled water systems a -300,000 Btu/h, indicate systems' are.conligured to automatically reset supply Water temperature based upon demand; or exception taken. If System pump motor hp -a 3 hp, also indicate controls automatically rectice flow by a 50%. For chilled water systems (a 300,000 Btu/h, pump motor hp a 3hp) that serve water-cooled unitary air conditioners, indicate VSD or staged pumps in chilled water sxstem and heat rejection loop that reduce pump flow so that one control yalve is ne.arly wide open, or to maintain a minimum differential pressure; or exception taken Integrated economizer operation - air and water Indicate -air and water -side economizers are configured for partial cooling operation even where additional mechanical cooling is required to meet the load NA C403.4.4.1 Single:duct VAV terminal units Indicate single duct terminal units are Configured to reduce primary supply air before reheating or recooling NA C403.32 • Economizer 88 09 system . impact - air and water Verify control method of HVAC systems with economizers does not increase. building heating • • . • • • - energy usage during normal operation NA• C403.4.4.2 Dual duct systems - terminal • units For systems with separate warm air and cool air ducts Indicate terminal units are configured to reduce the flow from one duct to minimum before mixing with air from the other duct Itatto TRES WEST ENGINEERS TRES WEST ENG.INEERS INC.. NA C4033.3.1 Air economizer Capacity Indicate modulating OSA and return air dampers are configured. to provide up to 100% OSA for cooling NA C403A.1.1 C403.4.1.2 VAV system static pressure sensort - . sensors and DDC set points Indicate locations of duct static pressure sensors on plans; include at least.one sensor per major duct branch; verify controller setpoint pressure at each sensor is:s 1.2 inch w.g. NA C403.3.1 C403.3.3.2 Integrated air economizer Verify mechanical cooling coetrols are interlocked with air economizer controls'so the outside air damper remains in 100% °Pen poSition when mechanical cooling is WO required to meet the cooling load, until the leaving air ternperature is 5 45'F- For systems with zone level DDC, indicate controls are configured to monitorzonedamper positions and reset static pressure setpoint based on the zone requiring .most pressure; include ontrol logic that automatically .detects and generates an alarm if any.zoneexcessively drives reset logic and allows building operators to exclude zones reset logic For systems with cooling capacity a 65,000 Btu/h, verify thatcontrol of economizer dampers is not based only oh mixed air temperature; or exception taken NA C403.4.2 Boiler sequencing Indicate. automatic controls that sequence.operation of multiple boilers NA C403.4.6 Hot gas bypass limitation For cooling equipment with hot gas bypass provide either multiple step unloading or . . . • ' .. • continuous capacity Modulation; indicate bypass capacity per Table C4C3A.6- NA C403.3.3.3 Air economizer high•limit controls- . . Indicate high limit shut-off control method and required high-lirnit per Table C403.3.3.3 NA C4034.2.2 Two -pipe changeover systems Indicate changeover deadbancl (min.15°F), heating / cooling mode scheduling and changeover temperature range (limit 30°F) NA. 0403.4.4.3 Multiple -zone VAV system ventilation optimization. controls. For' systems with zone leVel DDC controls, indicate controls are confieured to automatically reduce.rautdoor airflow in response to changes In system -ventilation efficiency; or exception taken NA C403.34.1 Water ecOnomIzer Capacity For eligible systems where Water -side Aeonomizer may be provided In lieu of air economizer; Indicate system is capableof -100% design cooling capacity at 50°F db / 45°F wb OSA temperatures NA 0403A.2.6 iCsollailetiroinbc'iler plant pump Indicate controls are configured to automatically reduce overall plant flow and shutoff flow through individual chillers and boilers:when not In use NA C403A.4.4 VAV systern supply air reset Indicate controls automatically reset supply air temperature in response to building loads or . . . . - outdoor air temperature; or exception taken NA C403.3.4.2 VVater econorniz.er maximum pressure drop Indicate pressure:drop across precoofing .coils and.heat exchangers in water economizer system do not exceed pressure drop limit NA C4032.13,1,1 C403.4.3.1.1 C403A.3.1.2 Heat rejection equipment,- variable flow control For cooling toWers with fan motors a 7.5 hp., indicate VSD and Method to adjust fan 'speed (adjuSted based on leaving fluid temperature or concfenser temperature/ pressure of heat • rejection device) 2702 SOUTH 42ND STREET, SUITE 'TACOMA, WA 98409-7315 Phone: 2.53.472.3300 www.treswest.com ItatiltS7M1777117.011917=00111711110111111 ) 301 (..) Ce }- tn a CO aasi C.0 0 0 N-- N - 0 1.-: C° Cf) X (f) °) 0? LI M < Cn ,.. 07 I- > 0) .4. *I. <e ZZI N--- ....... • C./) - C•1 Multiple Zone HVAC Systems, High Efficiency VAV - Required for systems utilizing C403.6 DOAS Exception 2, must comply. with all 16 provisions NA C403.3.1 DX air handling equipment control • • ' For DX air handlers with- economizer -and cooling capacity a 65,00013tu/h, refer to HVAC : System Controls for requirements For multiple -cell heat rejection equipment yvith VSD, indicate controls thot ramp all fans in unison NA C403,7' Item 1' Air economizer Indicate system is configured for 100% air economizer operation and cornplies with all related econonii±er requirements per C403.3 (withoirt ecenomtzer exceptions) NA C403.2.4.7 DX equipment economizer fault detection arid diagnostics For DX air handlers with- eConomiier and ctioling capacity a 54,-000 Btu/h, provide efault deteetiorrand diagnostic's (FDD) Systein to monitai economizer systern operation and report faults NA C403A.3.3 Heat rejection equipment - cooling tower flow turndown Indicate open-cireuit cooling towersarvith multiple pumps or VSD control are.designed so all cells can be run in parallel NA C403.7, Item 2 Direct digital controls (DOC) Provide DDC controls for all components of system; identify all DDC system' input/ output control points; indicate capability for trending and graphical disPlay NA C403.7, Item 3 Outdoor airflow measurement and reduction For systems with minimum OSA > 2,500 cfm, Indicate outdoor airflow monitoring station that measures OSA intake under all load conditions; indicate control sequence that increases or reduces system OSA cfm based on VAV terminal feedbadk.of ventilation efficiency (per C403A.4.3 without exceptions) or DCV (per C403.2.62) F. () simians < C\I * W tin LLI Nwftof to% %awl Z Systems Requiring Energy Recovery NA C403.4.2.3.1 Water loop heat pump - . deadband Indicate capability of central equipment to provide minimum 20°F water supply temperature deadband between heat rejection and heat addition modes; or exceptiontaken NA C403.5.1 Energy recovery. (ER) - ventilation / exhaust systems For systerns with design OSA > 5,000 cfm, or desige supply air cfm and % OSA exceeding the values.in Tables C403.5.1(1) -or (2), indicateexhaustair ER method; of exception taken with supporting calculations For rooms served by multiple systems with aggregate design OSA > 5,000 dm,- or aggregate design supply air cfrn and % OSA exceeding the values in Tables C403.5.1(1) or (2), indicate exhaust air E.F2 method; or exception taken with supporting calculations Indicate ER rated effectiveness that increase* OSA enthalpy by a 50% based on delta between OSA and return air enthalpies at design conditions NA C403.4.232.1 Wateloop heat pump - r heat rejection equipment Zone 4 Indicate type of cooling tower (open- or closed-circuit) in equipment sehodule; indicate method . used to limit system heat loss when heat:rejection is not needed NA C403.7, Item 4 Supply airflow measurement • For systems with minimum OSA > Z500 cfm indicate supply airflow monitoring station. capable • ' • of measuring supply air delivered to VAV terminals under all load conditions NA C403.4.2.3.2.2 Water loop heat pump - heat rejection equipment Zone 5 For open- or closed-circuit cooling towers, provide a heat exchanger the separates the cooling . • tower and heat pump loop NA C403.7; ltern 5 Zone isoletIon and maximum area served Verify maximum area served by a single HEVAV system is 5 50,000 sf, or one entire floor, whichever is greater; in addition if a system serves >25,000 sf, that includes areas that are expected to be occupied non-simultaneousty, indicate zone isolation controls per C403.2.4.4 NA C403.4.2.3.3. Water loop heat pump - isolation valves For hydronlc heat pump systems with total system power > 10 hp, indicete 2 -way isolation valves on each heat pump and variableflow system control NA • 0403.2.72 Laboratory exhaust systems (energy recovery) For buildings with tetanal) exhaust >5,000 cfm, Indicate method of energy recovery used to • . . ,, . pre -condition laboratory make - up air, ER effectiveness (min.25 9; or alternative method per exception (VAV exhaust, semi -Conditioned makeup, or CERM calculation) NA C403.7, Item 6 Interior / exterior zone desigtemperaturepply eir n su Verify that-VAV terminals serving interior cooling driven loads are sized per design supply -air temperature that is 5"F higher than VAV terminals serving exterior zones Prescriptive 7/1/2016 6/30/16 - , Dedicated Outdoor Air Systems (DOAS) Optional through NA C404.10.4 (under C404.11) Pools and permanent spas exhaust systems (energy recovery) For buildings with pools or spas with water surface area > 200 sf, indicate exhaust air ER method and pse efwaste heat (preheat ventilation air; pool water or service hot water); or exception taken NA C403.5 C403.6.3 Dedicated outdoor air systems For buildings with office, retail; education,tibrary and fire station spaces,identify these spaces. on plans;'indicate that ventilation air in each occupied space -is provided via a DOAS system; or document compliance with C403.6.3 Impracticality; or exception taken (buildings complying With 0402.4.1A or 0406.6 may not utilize:exceptions) NA C403.7, Item 7 Maximum air terminal inlet l veocity Identify air terminals with -minimum primary airflow setpoints > 50°A. of maximum setpoint in equiprnentschedule or MECH.:EC form; indicate air terminal Inlet velocity does not exceed 900 fpm () ‹C 00410 Z CO CL LLI CO F.03 0) Indicate ER system has the rated effectiveness and is configured to decrease the exhaust air temperature at design conditions by a 36°F NA 0403.7 Item 8' Sequence of operation Indicate DDC system sequences of operation are designed and configured per ASHRAE GPC 36 NA C403.6.1 Energy recovery ventilation with DOAS For all DOAS systems indicate exhaust air ER method; or exception talon with supporting • . calculations. Indicate ER rated effectiveness that increases OSA enthalpy by- a 50% based.on delta between OSA and return air enthalpies at design Conditions. NA C403'5.2 Energy recovery - steam condensate systems For b.uildings with on-site steam heating systems, indicate condensate water ER NA C403.7, Item 9 Maximum allowable system brake horsepower Verify fan system bhp is. 5 90°,4 of the bhp limit -per Option 2 equation in Table C.4032,11.1(1), provide MECH-FANSYS form for system For buildings that use off-site generated Steam -condensate is not returned to the source indicate on site condensate water ER NA C403.6.2 Heating / cooling system controls .with DOAS- Indicate equipment associated with the delivery of zone level heating ani cooling (fans; hydronic pumps pumps, primary air dampers, etc) ereconfiguredto shut off, an1 central equipment is . configured to tum down, when there is no call for heating or cooling in the zone they serve If applying Exception to heating / cooling fans used for air mixing. in the sake during deadearid periods; include fan watt* Per cfm in equipment schedule NA C403.7, Item 10 Fan powered terminal unit motor and control Indicate all series and parallel terminal fans havoielectronically commutated motors; indicate - DDC control system is configured to vary air terminal fan speed as a function of the load; indicate fan speed during periods of low heating; low codling, or ventilation 'only is s 66% of peak design air flow or provide supporting documentation for applied .exception F- (I) Cr) Z F. .. mem"' (ase) < 5 0 0 I () 00 4.5 ....., ti -c,' ot5 U-1 g N-i CI›.- Z I-: LLJ 2015 WaShingtOn State Energy -Cede COMplianCe.Forms for COmmercial, R2 and R3 over 3 StOries .and. all R1.- Page 'M,eChanical Pe ,mitPlans Checklist 7 of 7 MECH-CHK 2015 VVashington State Energy. Code Compliance Fprms for Comniercial, R2 and R3 pver 3 stories and all •Economizer Exceptions MECH-ECn, 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 steries and all R1 Revised R1 NO, , 2015 VVashington State Energy Economizer Exceptions, 2015 Washington State Energy Code COmpliance Code Compliance Formsjor Commercial, R2 and R3 ever' 3 cont istOries and all R1 MECH-ECONO and all R1 Revised January 2017 I . , * a" (,.....2 UJ Lci H >) () w 0 mmj i ULI ti" 2015 VVashingion State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 ever3 stories andel' R1 Revised' January 2017 January 2017 Forms. for Commercial Buildings including R2. & R3 over .3 stories Project Title: illkwilla PlIblic Schools Technology & Maintenance D.ate 8/8/2017 Project Title: Tukvvilla Public. Schools Technology 8, Maintenance. Date -8/8/2 017 Project Title: Date 8/8/2017 4404: C) .r. () '1" The following information is necessary to check a permit application for compliance with the mechanical systems and equipment.requirements cif the. Washington State Energy Code Commercial Provisions. All cooling systems shall be configured to provide air economizer operation, regardless of system capacity, for new construction and mechanical system alterations. Various exceptions to this requirement are available. Identify all systems that an economizer exception will be 'applied tO and additional information as noted below. Foi Building pept. Use Economizer Exception Summary Refer to Section C403 3 for deScriptions of eConomizer provisions and exceptions. For 'alterations refer tOSection C503.4 and Table C503.4. ECONOMIZER EXCEPTIONS - NEW CONSTRUCTION AND ADDITIONS; CONTINUED 111011101111.1 Z sesemoso Applicable (yes,no,na) Code Section Code Provision Infeimation Required - Must be in permit docurnents Location in Documents Building Department Notes Ex p 10 Cooling equipment for dedicated serveri.electronic equipment or telecom switchrooms. Per building limit for this exception is 240,000 Btu/h cooling capacity or 10%.ef required building air economizer capacity, whichever is greater. Part load control required over -85,000 Btu/h. Additional requirements apply. Option -a - Cooling equipment efficiency shall be 15% better than the WSEC required minimum efficiency.. Option b --Waterside economizer required. Cooling equipment efficiency shall be 5% better than the WSEC required minimum efficiency. Option c - Waterside economizer required. All cooling equipment is subject to ASHARE Standard 127. Total Totatbuilding air economizer capacity Alternate System ID Compliance . OptiOn. Cooling Capacity (Btu/h) I w".1' ani: > Hn >l< () Or ° NA C403.7, Item 11 Application of single duct and fan -powered terminal units Indicate VAV terminal types.on plans; verify fan -powered terminal units only serve pelimeter zones with envelope loads verify all other zones are served by single duct terminal units AC-01/CU.-01 Option a 29,500 CO ee :D :3 Lii Ill 0 NA C403.7, Item 12 . Fan -powered terminal unit primary. air reset Indicate L)DC controls are configured to automatically reset the primary supply air cfm setpoint of all fan -powered terminal units to the minimorn required to maintain ventilation durihg occupied heating or deadband, based upon the VAV air handling unit OSA ventilation fraction Economizer Exception Summary to Section . C403 3for descriptions of economizer provisions and . exceptionsFor alterations refer to Section C503.4 and Table C503.4. ECONOMIZER EXCEPTIONS - NEW CONSTRUCTION.AND ADDMONS Exp 1 Cooling equipment serving spaces that are provided with a dedicated outdoor air system (DOAS) per C403.6. Spaces served shall have year round design cooling loads from lights and equipment less than 5 watts per square foot. System ID Lighting + Equipment Loads (W/sf) NA C-403.7, Item:13 High occupancy space controls- For spaces > 150,0 with occupantdensity.a 25 peop1011000 sf, Indicate space Is served by a dedicated terrninal unit with DCV control that resets terminal unit ventilation setpoint; also indicate occupancysensorcontrol that automatically reduces minimum ventilation to zero and sets back roam heating and cooling setpoints by a 5QF REVISION DATE Claimed ExemptCapacity: (if claimed > 240 kBtu/h): Exp 10 Capacity Limit: NA' C403.7Indicate Item 14 Dedicated HVAC systems For seriret, electronic equipment telecom or similar spaces With cooling loada> 5 VV/st spaces are served by independent HVAC systems that are separate from HPVAV • • • . . , .. , , , .. .. systems serving rest of building; indicate dedicated -MAC systems.have air economizer controls or energy recovery per C4033 Exception 9 29,5po Exp 2 Single zone unitary or package systems with dehumidification thataffectSystem other systems.such that air economizer would increase energy consumption. ID NA 0403/, Item 15 Central plantefficiency Indicate whether systems are served by a high efficiency heating water plant, or 0 high effiCiency chilled water plant heating water plant Indicate all VAV terminals have hydronic If complying via high efficiencyRefer heating•coilsserved by heating water system With either.gas-fired boiler(s) with thermal effitiency a 90%, air -to -Water heat pumps or heat recovery chillers ECONOMIZER EXCEPTIONS - N1ECHANICAL SYSTEM ALTERATIONS ORREPLACEMENT C50?A Pre approved design alternative to full compliance with an economizer Exp 1 requirement. An alternative for mechanical system alterations where existing building .constraints make full compliance with air economizer requirement. impractical. Provide calculations to the code official that demonstrate the. proposed alternate design strategy provides similar energy savings to the annual energy that would be saved by the"eooling system with air economizer per C403.3. System ID Alt. Strategy . Exp 3 High efficiency single zone unitary or packaged systems. Equipment cooling efficiency.shall be better than the WSEC required minimum efficiency by at least 64% in Climate Zone 4C and 59% in Climate Zone 5B per Table Cztoq.3. System ID If complying -via high efficiency chilled water plant Indicate ell VAV air handlers have cooling. coils served by chillers with rated IPLV efficiency that exceeds WSEC listed IPLV by at least 25%perTahle 0403.2.3(7) (note water IPLV is max, all others are. min)indicate ; smallest chiller or compressor in plant is 5 20%. of total plant capacity, or provide thermal storage sized fors 20% of total plant capacity NA 0403.7, Item 16 Fault detection and diagnosfic* Indicate DDC system includes a fat* detection and diagnostics (FDD) system configured to monitor operation and provide fault reporting of required pararneters for all VAV air.handlers. and VAV air terminal units in the HPVAV system Exp 4 Equipment that provides hydronic chilled water for chi/ted beams.and chilled .ceiling. systems thatisserved by a water economizer system per C403.3A in lieu Of air economizer. System ID ECONOMIZER EXCEPTIONS - SIMPLE SYSTEMS • C503.4 Qualifying small equipment. Per unit limit less than 33,000 Btu/h. Per Exp 2 building limit for thisexceptionis 721000 Btu/h cooling 'capacity or 5% of required building air economizer capacitywhichever is greaterCooling , . equiprn.ent efficiency shall be 1.5% better than WSEC required minimum efficiency. Not eligible: non -unitary equipment, unitary equipment installed outdoors or in mech room adjacent to outdoors, equipment installed during new construction, shell -and -core construction, or initial tenant improvement. Total Claimed Exempt Total building air economizer capacity (if claimed > Alternate C503A.Exp 2 System ID Cooling Capacity. (mum) Design: RSH Drawn: MAM Checked: RSH Project No. 331-16-01 HVAC Equipment Energy Use Metering NA C409.3.1 HVAC equipnient energy . use metering For new buildings > 50,000 sf and building additions > 25,000 sf, verify energy use metering of . : • . . • - . . - , . . .. .. • . all equipment use.d to provide space heating and cooling, dehumidification and ventilation will be provided per C409; indicate equipment eligible for exception Exp 5 Water -source. heat pumps with heat recovery. Heat pump efficiency shall be 15% better than WSEC required minimum efficiency. Provide at minimum 60% air economizer. Energy recovery to preheat OSA shall have at least 50% effectiveness. Additional system requirements apply, System. ID Documentation and System Specific.Requirement To Support Commissioning Yes C408-.2 Scope of mecanica hl systems commissioning indicate that all mechanical systems, equipment, and controls for which the WSEC requires control functions and / or configuration to perform specific functions are required to be commissioned; Fcir buildings with a 240,000 Bturli total output cooling capacity or a 300;000 Btu/h total output heating -capacity, indicate that all mechanical systems regardless of Individual capacity are required to be commissioned; or provide building heating /cooling capacity calculation demonstrating -eligibility for exception BM0.01 Exp 6 Cooling equipment serving Group R occupancies. Per unit limit is less than 20,000 Btu/h cooling capacity for equipment installed outdoors or in a mech room adjacent to the outdoors. For cooling equiprnent installed in other locations the unit limit is less than 54,000 Btu/h. Efficiency shall be 15% better than WSEC required minirnum efficiency. System ID EquipMent Location Pooling Capacity (Btu/ft) Capacity: 72,000 Eituth): Capacity Limit: Yes C403.2.10 c408.1.1 C408.1.2 C408.1.4.2 C103.6 Commissioning requirements in construction documents Indicate in plans and 'specifications that Cx per C408 is required for all appficable mechanical systems; Include general summary with at a minimum of Items 1 thru 4 of the Cx plan per -C408.1.2 including: narrative.description of activities, responsibilities of the Cx team, schedule of activities IneludIng verification of project close out documentation per C103.6, and conflict of interest plan (if required); Include In general summery that a Cx project report or Compliance Checklist (Figure C408:142) shall be completed by the Certified Cx Professional and provided to the owner prior to the final mechanical inspection. BM0.01 BM0.01 BM0.01 C503.4 Equipment that provides hydronic chilled water for chilled water terminal Exp 3 units. Equipment part load cooling efficiency.(IFIV) shall. be better than VVSEC required minimum efficiency by at least 25%. Per building limit for this exception is 480,000 Btu/h cooling capacity or 20% of required building air economizer capacity, whichever is greater. Chilled water terminal units serving Group R occupancies are not included in the building capacity total. Total Claimed Exempt Total building air economizer capacity (It claimed > Alternate C503A Exp.3 System ID Cooling Capacity. (Btu/h) Issuance BID SET Date:11/6/2017 Exp 7 Variable refrigerant.flow (VRF) syste.ms with energy re.covery. Outdoor unit shalt be a reverse -cycle heat pump with variable speed compressor(s) and condenser fan(s). Outdoor unit cooling capacity shall be not less than 65,000 Btu/h. Energy recovery to preheat outdoor air shall have at least 50% rated effectiveness. System shall be capable of providing simultaneous heating and cooling by.tranferring recovered energy from zone(s) in cooling mode 10 other zone(s) that are in heating mode. Outdoor Unit system ID Cooling Capacity (Btu/h) Capacity: 480,000 Btu/h): C. apacity Liniit: Yes C408,22 Air system and hydronic . system balancing Indicate in plans that air and fluid flow rates shall be tested and balanced within the tolerances . . . . . . . defined in the specifications; indicate systems' shall be balanced in a manner to first minimize throttling lossea, then adjusted to meet design flow conditions BM0.01 Exp 8 Cooling :equipment serving Controlled Plant Growth Environments. Equipment Cooling efficiency shall be better than yvsEc. required minimum efficiency by at least 200/9, Not eligible: unitary and applied heat pumps. system ID SEER, EER, & IEER Table Compliance Options for alteration' or replacement of -existing C503.4 mechanical. Cooling equipmerit per Table C5014. Refer to table and all applicable table footnotes for full requirements. Applies to the following retrofit conditions: Option a - Any new or replacement equipment Option b - Replacement equipment of same type With same or. smaller cooling output capacity. - Option c - Replacement equipment of same type with large cooling output capaCity. Option d - New equipment added to existing system or replacement equipment that is'different than existing being repladed. System ID EqUiprilpilt Type Compliande Path Yes C4082.21 Air systein balancing • devices Indiote•devices that provide the capability trx balance all supply air outlets, zone temanals.and air handling equipment requiring system balancing BM0.01. , Drawing Title MECHANICAL COMPLIANCE FoRms NA • :. ;. C40e.2,2.2 Hydronic syStem balaribing: devices Indicate devices that proVide the.caOabilityito isolate, balance and Measure flaw aeross all hydronic equipment requiring system balancing Including heating and cooling coifs and pumps Yes 0408.23 - Functional performence i . . testing critena Identify In plans and specifications the -intended operation of all equipment and controls during all modes Of operation, including interfacing between new and existing -to -remain systems BM0.01 Exp 9 Cooling equipment with energy recovery: Space served have year-round design cooling.loads from lights and equipment greater than 5 watts per square foot. Energy recovery system shall utilize recovered energy for on-site space heating or preheating of service hot water. Provide calculations to the code official that demonstrate the amount of - rectiverecl energy used for on-site heating purposes is equivalent to the annual energy that would be.saved by the cooling system with air economizer per C403.3. System ID Lighting + Equipment Loads (VV/st) Project apse Out Documentation .Yes 0103.6 Documentation end project . close out submittal requirements nl dicate in plans:that project.close out documentation and training of building operations personnel is required fore!! mechanical comp.onents,•equipment and systems governed by this code: indicate close out documentation shall Include: record documents O&M manuals, • ' .1 • . • - -: applicaole WSEC compliance forms and calculations BM0.01 Drawing Number BMCF.0200) I COPYRIGHT (0 2015 Rot.LuDA ARCHITECTS INC BM0.01 - LEGEND.DWG 2 2015 Washington State Energy Code Compliance Forms for Commercial, R2: and R3 over 3 stories and all R1 Mechanical )Fan System Power Allowance MECH FA,NSYS StM 2015 Washington State Energy Code. Compliance. Forms far Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised January 2017 Project Title: Tukwilla Public Schools Technology & Maintenance. Date 8/8/2017 For Building Dept. Use HVAC Air Distribution System Schedule List all HVAC systems that have the capability to provide heating andior cooling to the spaces they serve. System or Primary Supply Fan ID', Speed Control (Note 1) Description (Note 2) System Total Nameplate HP (Note 3) Fan Power Calculation Required (Note 4) AC-011CU-01 CV Split System Air Conditioner 0.069 No Note 1 Constant Volume (CV), Variable Air Volume (VAV), or HospitallLab CV system that qualifies for VAV budget per C403.2.11.1 Exception 1. Single zone VAV systems shall comply as CV. Note 2 -Describe system type and list all fans (or groups of fans) associated with the delivery and removal of conditioned air by the system. Include all supply, return/relief, exhaust and exhaust hoods (>1 hp), make-up air, dedicated outside air (DORS), booster fans, and series fan -powered terminals. VAV parallel fan -powered terminals and economizer relief fans do not need to be included if the fans do not operate at peak conditions. ive and Note 3 -Enter the total nameplate hp of all fans associated with the- deliver}, removal of conditioned nditioned airby the system. Note 4 - This form automatically identifies whether a MECH-FANSYS form is required to demonstrate compliance with thefan power allowance (Yes); or this information is. not required because the system has a combined total nameplate motor hp that is 5 hp or less (No) MECH-FANSYS Forms A MECH-FANSYS form shall be provided for each system with total nameplate hp greater than 5 hp. Select (Add Fan System Form) to generate an additional form. Added forms can be deleted with button in cell E32 of the added form. REVIEWED FOR CODE COMPLIANCE APPROVED FEB 0 7 2018 BU City of Tukwila 1!. SION RECEIVED C1TY OF TUKWILA FEB 0 2 2018 PERMIT CENTER r i dd ... re architecture planning interior deign 105 S. Main Street Suite 323 Seattle, WA 98104 t: 206-624-4222 f: 206-624-4226 1.#1.TREs WEST ENGINEERS TRES WEST ENGINEERS, INC.. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com 1 V It L� ��rr' W V Fe /y W co — co CU W 2 ct O 05 W w 1rti a C. c-4 WIr CoL)t,-) 0 < Ct id W tfr- co C3M I V i Q N. = L.1r o O - 0 N D D W W 8 w' o J a""'. �i- 1. - r- 1 -- REVISION DATE Design: RSH Drawn: MAM Checked: RSH Project No. 331-16-01 Issuance BID SET Date: 11/6/2017 Drawing Title MECHANICAL COMPLIANCE FORMS Drawing Number BMCF.03 COPYRIGHT 2015 ROLLUOA ARCHITECTS INC BM0.01 - LEGEND.DWG ELECTRICAL 111 BREAK RM 110 WORK ROOM 109 1......... 4#1// Co,or adol0 #ftr Pr id it STACISIREADINC ..................... /-74/71/24/74/-74//7/,////,774/747/74/7e7/7e-7(z,I..........._105 CI --I/3 OF�IC�E= 108 II II II II '1I 16 =nun g 611 STODIAI 107 .ENTRY LOBBY 100 1 EN'S TOILET 101 WOMEN'STOILET 102 -l"RAINING ROOM 103 DEMOLITION PLAN - HVAC SCALE : 1l8 1'-0" (.f GENERAL DEMOLITION NOTE: 1. ALL EXISTING EQUIPMENT, PIPING, DUCTWORK, CONTROLS AND OR WIRING SHOWN IS A REPRESENTATION OF THE ACTUAL SYSTEMS AND IS NOT TO BE CONSIDERED AN AS -BUILT. ALL DIMENSIONS, LOCATIONS AND QUANTITIES SHALL BE FIELD VERIFIED PRIOR TO COMMENCEMENT OF DEMOLITION OR NEW CONSTRUCTION. DEMOLITION PLAN NOTES: `:./ CROSS HATCH PATTERN INDICATES EXISTING DUCTWORK, AIR DEVICES AND ASSOCIATED AIR SYSTEM ACCESSORIES TO BE REMOVED. 02 EXISTING ROOF MOUNTED AHU SHALL REMAIN IN PLACE FOR RE -USE, SEE SHEET BM1.01 FOR NEW WORK AND SHEET BM2.01 FOR ROOF PLAN. 0 O O EXISTING BRANCH DUCTWORK BEYOND TO REMAIN AS IS. EXISTING AIR DEVICE TO BE REUSED. DISCONNECT AND REMOVE BRANCH SUPPLY OR RETURN DUCTWORK. DIFFUSER LOCATIONS SHALL SHIFT SLIGHTLY BASED ON NEW CEILING GRID. EXISTING THERMOSTAT TO REMAIN AS IS. EXISTING THERMOSTAT AND ASSOCIATED WIRING SHALL BE REMOVED AND SALVAGED FOR RE -USE. SEE SHEET TM1.01 FOR NEW LOCATION OF THERMOSTAT. REVIEWED FOR CODE COMPLIANCE APPROVED FEB 0 7 2014 City of Tukwila tatacily,j,WN RECEIVED CITY OF TUKWILA FEB 0 2 2018 PERMIT CENTER rol a f rh � � y .N/ architecture planning interior de 105 S. Main Street Suite 323 Seattle, WA 98104 t: 206-624-4222 f: 206-624-4226 4s7orrat, 43283:� 40 sv 11/06/17 11°<1. TRES WEST ENGINEERS TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472,3300 www.treswest.com LU C � LLrld< E 00 r - W. CO C/ Z0 16" st7 W W_ 0 0 F— H � 0 a- """ W CC) O <CtolLUt.: . 0 F- N":"I a: 5 it - 0 rt fi) D.. D WW REVISION DATE Design: RSH Drawn: MAM Checked: DMM Project No. 331-16-01 Issuance BID SET Date: 11/6/2017 Drawing Title HVAC DEMOLITION FLOOR PLAN Drawing Number BMD1.01 2 co COPYRIGHT @ 2015.ROLLUDA ARCHITECTS MCI— 1 ELECTRICAL MAINT/STOR. OFFICE 115 GENERAL NOTES: 1. COORDINATE LOCATION OF ALL GRILLES, REGISTERS AND OR DIFFUSERS WITH ARCHITECTURAL ELEVATION AND INTERIOR DRAWINGS. REFER TO SHEET BM0.02 FOR INSTALLATION DETAILS. OFFICE 116 OFFICE 117 8"0 18x18 18x18 DN BREAK RM 112 KITCHEN 110 WORK ROOM 109 OFFICE 108 20x14 )AC -3 —RSL/RLL & CONDENSATE UP TO ROOF. RECEIVING L 106 TRAINING HALLWAY I . 105__ 1 8"0—' 6"0 10"0-� STORAGE 20x18 20x18 18x14 8"07 - TYPICAL ( 2 10x10 LINED TRANSFER DUCT, TYPICAL. VOLUME DAMPER, TYPICAL. OPEN OFFICE 114 10"0, TYPICAL 10x10 LINED TRANSFER DUCT, TYPICAL. CONFERENCE CUSTODIAN 107 18x12 (E)20x18 ENTRY LOBBY (E)AC-2 STORAGE MEN'S TOILET TRAINING ROOM I1 CA) B FLOOR PLAN - HVAC SCALE : 1/8" = 11-0" EC' PLAN NOTES: 0 0 0 0 0 0 2 3 EXISTING DUCTWORK MAIN LOCATED ABOVE CEILING TO REMAIN AS IS BEYOND THIS POINT. CONNECT 20"x 16" RETURN AIR DUCT TO EXISTING 20"x 16" RETURN AIR MAIN ABOVE CEILING IN THIS AREA. BALANCE TO 2290 CFM. TRANSITION AND CONNECT 20"x 16" SUPPLY AIR DUCT TO EXISTING 16"x 20" SUPPLY AIR MAIN ABOVE CEILING IN THIS AREA. BALANCE TO 2290 CFM. CONNECT 20"x 18" RETURN AIR DUCT TO EXISTING 20"x 18" RETURN AIR MAIN ABOVE CEILING IN THIS AREA. BALANCE TO 2265 CFM. CONNECT 20"x 18" SUPPLY AIR DUCT TO EXISTING 20"x 18" SUPPLY AIR MAIN ABOVE CEILING IN THIS AREA. BALANCE TO 2265 CFM. CONNECT 10"x 10" SUPPLY AIR DUCT TO EXISTING 20"x 18" SUPPLY AIR MAIN ABOVE CEILING IN THIS AREA. BALANCE TO 375 CFM. ELECTRICAL 111 MAINT/STOR. 113 BREAK RM 112 KITCHEN J '"18x8 ��/ 110 WORK ROOM 109 OFFICE 108 0 10 11 12 BALANCE TO 390 CFM. CONNECT 12"x 14" SUPPLY AIR DUCT TO EXISTING 12"x 14" SUPPLY AIR DUCT ABOVE CEILING IN THIS AREA. BALANCE TO 890 CFM. CONNECT DUCT, SIZE AS NOTED, AND RELOCATE AS SHOWN. BALANCE TO CFM INDICATED. RELOCATED THERMOSTAT PREVIOUSLY SALVAGED UNDER DEMOLITION PHASE. MOUNT AT 4'-0" A.F.F. FIELD VERIFY EXACT LOCATION OF EXTERIOR MOUNTED CONDENSING UNIT AT ROOFTOP MECHANICAL ENCLOSURE.. MOUNT UNIT ON SLEEPERS, COORDINATE WITH ELECTRICAL FOR SERVICE AND DISCONNECT LOCATION. RELOCATE EXISTING DIFFUSERS TO ALIGN IN NEW CEILING AS SHOWN. PROVIDE NEW FLEX TO MAIN, TYPICAL OF 2. r '-7' 8 Yj 15x80 0 6x6 O 30012 / '\ 12x121 ; x� \..1300 I O10x10 260 .............._. I NI O81320 z ®ri /"`110x10 �l175 C 20x24 2290 (1'-0" AFF) OFFICE 115 OFFICE I 116 OFFICE 117 TN] RECEIVING 0x10 NJ 200 906x6 4J CUSTODIAN OA 107 106 B 24*24 820 HALLWAY 105 A 8".0 160 (TYP. OF 3) 10x10 TG -1 (TYP. OF 6) 10"3 280 (TYP. OF 6) OPEN OFFICE AO8"21 195 ENTRY LOBBY 100 TRAINING 118 CONFERENCE O10.0 �✓ 275 120 06"� 75 STORAGE 119 010"G 275 MEN'S TOILET 101 STORAGE 1 104 WOMEN'S TOILET 102 Ei.(E) RG -1 ►,1 (E) 360 CFM TRAINING ROOM 103 114 1 10x10 TG -1 (TYP. OF 4) (E) 360 CFM B REFLECTED CEILING PLAN - HVAC SCALE : 1/8" = 1'-0" CcD 0 REVIEWED FOR CODE COMPLIANCE APPROVED FEB 0 7 2018 City of Tukwila a_Apit G DtyISLON RECEIVED CITY OF TUKWILA FEB 0 2 2018 PERMIT CENTER 1 rolluda architects architecture planning interior design 105 S. Main Street Suite 323 Seattle, WA 98104 t: 206-624-4222 f: 206-624-4226 TRES WEST ENGINEERS TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com rW� W <0 Z 00< Ct _Qz aW CI�Wz a 15 C7 00 Z C..)0—OWE (i) L✓ 0 6 CCtJW� J 0 L >< ce .. DDW Wa (/) U H CI —J 00 U 1!— 4640 S 144TH ST. 0 ti C ) C) ti 0) C0 0 N J w REVISION DATE Design: RSH Drawn: MAM Checked: DMM Project No. 331-16-01 Issuance BID SET Date: 11/6/2017 Drawing Title HVAC FLOOR & REFLECTED CEILING PLANS Drawing Number BMI.O1 BM1.01 - FLOOR PLAN MECHANICAL.DWG co ci r -- (-A N CO COPYRIGHT 0 2015 ROLLUDA ARCHITECTS INCT- r 1 GENERAL NOTES: 1. ALL EQUIPMENT, PIPING, DUCTWORK, CONTROLS AND OR WIRING SHOWN IS A REPRESENTATION OF THE ACTUAL SYSTEMS AND IS NOT TO BE CONSIDERED AN AS -BUILT. ALL DIMENSIONS, LOCATIONS AND QUANTITIES SHALL BE FIELD VERIFIED PRIOR TO COMMENCEMENT OF DEMOLITION OR NEW CONSTRUCTION. PLAN NOTES: QFIELD VERIFY EXACT LOCATION OF EXTERIOR MOUNTED CONDENSING UNIT AT ROOFTOP MECHANICAL ENCLOSURE. MOUNT UNIT ON SLEEPERS, COORDINATE WITH ELECTRICAL FOR SERVICE AND DISCONNECT LOCATION. AC -1 AC -3 CU -01 AC -2 -r CONDENSING UNIT MOUNTED ON ROOF RSL/RLL &-314" CONDENSATE DN. 3/4" CONDENSATE, DISCHARGE TO ROOF HVAC ROOF PLAN SCALE : 1/8" = 1'-0" ,J SECURE TO CURB PER MANUFACTURERS INSTALLATION INSTRUCTIONS. APPLY SEALANT AT FASTENERS. 18 GAUGE GALVANIZED SHEET METAL CAP. OVERLAP CURB MIN 2". CANT STRIP ROOF MATERIAL ROOF INSULATION ROOF DECK CONDENSING UNIT MOUNTED ON ROOF SCALE: NONE FAN COIL UNIT l 1 WALL SLEEVE INSULATED REFRIGERANT PIPING TO OUTDOOR UNIT ..1 CONDENSING UNIT NEOPRENE PAD AT UNIT MOUNTS. INSULATED REFRIGERANT PIPING WITH SLEEVE SHEET METAL ENCLOSURE EQUIPMENT CURB. INSTALL EQUIPMENT AND CURB LEVEL. ROOF FLASHING CONDENSATE DRAIN PIPE. ROUTE TO ROOF. SEE SHEET BM2.01. INSULATED. FLEXIBLE DRAIN HOSE. INSERT SECURELY INTO CONDENSATE DRAIN PIPE. CONDENSATE PUMP REFRIGERANT LINE FLARED CONNECTION POWER. AND CONTROL WIRING TO OUTDOOR UNIT (LINE. VOLTAGE) WALL MOUNTED SPLIT -SYSTEM - INDOOR UNIT SCALE: NONE ROOF MOUNTED EQUIPMENT BASE SECURE EQUIPMENT BASE WITH WASHER AND LAG BOLT THROUGH VIBRATION ISOLATOR AND PREFABRICATED ROOFTOP EQUIPMENT SUPPORT MEMBER TYPE IP -1 VIBRATION ISOLATOR / A SUPPORT MEMBER, CANT AND FLASHING, SEE ARCH DWGS FINISHED ROOF AND INSULATION, SEE. ARCH DWGS 1 NOTES: 1. TOP OF ROOFTOP EQUIPMENT TO BE LEVEL WHERE INSTALLED ON SLOPED ROOFS. DETAIL - ROOFTOP EQUIPMENT SUPPORT SCALE: NONE REVIEWED FOR CODE COMPLIANCE APPROVED FEB 0 7 2010 • City of Tukwila tVISION RECEIVED CITY OF TUKWILA FEB 0 2 2018 PERMIT CENTER r � r" y llUdd a! / architecture panning intro for design 105 S. Main Street Suite 323 Seattle, WA 98104 t: 206-624-4222 f: 206-624-4226 Iletv TRES WEST ENGINEERS TRES WEST ENGINEERS, INC;. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com V 0 0 62 E co Ct7 r GlyCl Z 0 16 7:7( !r. w ct w 0 0 12 I a >— W Cf) » O < ct„, 5 n: it x 0 ct REVISION w a DATE Design: RSH Drawn: MAM Checked: DMM Project No. 331-16-01 Issuance BID SET Date: 11/6/2017 Drawing Title HVAC ROOF PLAN Drawing Number BM2.01 BM2.O1 - ROOF PLAN MECHANICAL.DWG. 10 0 COPYRIGHT 0 201.5ROLLUDA ARCHITECTS 1NC Op