Permit M18-0020 - ICON OWNER POOL 1 WEST LLC - ROOFTOP GAS-ELECTRIC UNIT REPLACEMENT
ICON OWNER POOL 1 WEST LLC 1191 ANDOVER PARK W EXPIRED 08/14/18 MI 8-0020 Parcel No: Address: eieN City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 3523049093 Permit Number: M18-0020 1191 ANDOVER PARK W Project Name: ICON OWNER POOL 1 WEST LLC Issue Date: Permit Expires On: 2/15/2018 8/14/2018 Owner: Name: Address: ICON OWNER POOL 1 WEST LLC 2 N RIVERSIDE STE 2350, CHICAGO, WA, 60606 Contact Person: Name: KEITH RICE Address: 1012 CENTRAL AVE S , KENT, WA, 98032 Contractor: Name: Address: License No: Lender: Name: Address: PERFORMANCE HEATING & A/C INC (CONST) 1012 CENTRAL AVE S , KENT, WA, 98032 PERFOHA15ORT Phone: (425) 251-0356 Phone: (425) 251-0356 Expiration Date: 4/30/2019 DESCRIPTION OF WORK: REPLACE (1) ROOFTOP PACKAGE GAS -ELECTRIC UNIT Valuation of Work: $13,000.00 Type of Work: REPLACEMENT Fuel type: GAS Fees Collected: $381.86 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Permit Center Authorized Signaturehi Ou : le Date: lg I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development per it a d agree to the conditi s attached to this permit. Signature: Date: Print Name: ire.- / T'l This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: The attached set of mechanical plans have been reviewed by The Tukwila Fire Marshals Office and are acceptable with the following concerns: 2: H.V.A.C. units rated at greater than 2,000 cfm require auto -shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2437) 3: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air -moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 4: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2437) 5: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2437) 6: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 7: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 8: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 9: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 10: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. 11: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 12: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 13: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 14: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 15: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 16: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 17: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 18: ***MECHANICAL PERMIT CONDITIONS*** 19: All mechanical work shall be inspected and approved under Permit Center (206/431-3670). 20: Manufacturers installation instructions shall be available on PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1400 0703 1800 0705 0701 0702 FIRE FINAL MECH EQUIP EFF MECHANICAL FINAL REFRIGERATION EQUIP ROUGH -IN MECHANICAL SMOKE DETECTOR TEST a separate permit the job site at the issued by the City of Tukwila time of inspection. CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. 1\A \ U / O '° Project No. Date Application Accepted: Date Application Expires: (For office use only) It t(6 MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION King Co Assessor's Tax No.: 352304-9093 Site Address: 1191 Andover Park West Suite Number: NA Tenant Name: NA VO O QW per\ 1 'N'yT wCi New Tenant: PROPERTY OWNER Name: ICON OWNER POOL 1 WEST LLC 549999 Address: 2 N RIVERSIDE STE 2350 City: CHICAGO State: IL Zip: 60606 CONTACT PERSON - person receiving all project communication Name: Keith Rice Address: 1012 Central Ave S City: Kent State: WA Zip: 98032 Phone: (425) 251-0356 Fax: Email: keith.r@pmghvac.com Floor: ❑ Yes ® ..No Roof MECHANICAL CONTRACTOR INFORMATION Company Name: Performance Mechanical Group Address: 1012 Central Ave S City: Kent State: WA Zip: 98032 Phone: (425) 251-0356 Fax: Contr Reg No.: PERFOHA15ORT Exp Date: 04/01/2017 Tukwila Business License No.: bus -0992987 Valuation of project (contractor's bid price): $ 13,000 Describe the scope of work in detail: Replace (1) Rooftop package gas -electric unit. Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement Fuel Type: Electric Gas Other: li:'.Applications'Forms-Applications On Line,20I6 Applications,Mechanical Permit Application Revised I-4-I6.docx Revised: January 2016 kis Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Residential, Nighttime Furnace >100k btu Industrial Floor furnace 55 dB(A) Suspended/wall/floor mounted heater 57 dB(A) Appliance vent Commercial Repair or addition to heat/refrig/cooling system 47 dB(A) Air handling unit 65 dB(A) <10,000 cfm 1 Unit Type Qty Air handling unit Residential, Nighttime >10,000 cfm Industrial Evaporator cooler 55 dB(A) Ventilation fan connected to single duct 57 dB(A) Ventilation system Commercial Hood and duct 47 dB(A) Incinerator — domestic 65 dB(A) Incinerator — comm/industrial 60 dB(A) Unit Type Qty Fire damper Residential, Nighttime Diffuser Industrial Thermostat 55 dB(A) Wood/gas stove 57 dB(A) Emergency generator Commercial Other mechanical equipment 47 dB(A) 60 dB(A) 65 dB(A) Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-10PM, Monday through Friday and 8AM-10PM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: • Warning devices; • Construction and property maintenance during the daytime hours (lam-lOpm); • Testing of backup generators during the day. Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWN AU HCED AGENT: Signature: /i Date: 01/23/2018 Print Name: Keith Rice Day Telephone: (425) 251-0356 Mailing Address: 1012 Central Ave S Kent WA 98032 City State Zip H: Applications Torms-Applications On Line\2016 Applications,Mechanical Permit Application Revised 1-4-16.docx Revised: January 2016 bh Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID M18 -00x0 Address: 1191 OVEI n 35230490 Credit Card Fee .12 Credit Card Fee R000.369.908.00.00 0.00 $11.12 MECHANICAL $356.48 PERMIT ISSUANCE BASE FEE PERMIT FEE PLAN CHECK FEE R000.322.100.00.00 R000.322.100.00.00 R000.322.102.00.00 0.00 0.00 0.00 $33.15 $252.03 $71.30 TECHNOLOGY FEE $14.26 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R13705 R000.322.900.04.00 0.00 $14.26 $381.86 Date Paid: Monday, February 05, 2018 Paid By: KEITH RICE Pay Method: CREDIT CARD 667146 Printed: Monday, February 05, 2018 4:03 PM 1 of 1 IRWSYSTEMS 7/2/2018 City of Tukwila Department of Community Development KEITH RICE 1012 CENTRAL AVE S KENT, WA 98032 RE: Permit No. M18-0020 ICON OWNER POOL 1 WEST LLC 1191 ANDOVER PARK W Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 8/14/2018. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or fmal inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 8/14/2018, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: M18-0020 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 HERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M18-0020 DATE: 02/08/18 PROJECT NAME: ICON OWNER POOL 1 WEST LLC SITE ADDRESS: 1191 ANDOVER PARK W X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: P AWUflic6 Building Division Public Works �M PWS 146 Fire Prevention Structural Planning Division ❑ Permit Coordinator ❑ PRELIMINARY REVIEW: DATE: 02/08/18 Not Applicable ❑ Structural Review Required (no approval/review required) REVIEWERS INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 03/08/18 Approved Corrections Required ❑ Approved with Conditions ❑ ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWERCS INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping ❑ PW 0 Staff Initials: 12/18/2013 PERFORMANCE HEATING & A/ NC Home Espanol Contact Safety & Health Claims & Insurance 4:1) Washington State Department of Labor & Industries Search L&I Page 1 of 2 ARC A -Z 1tdex l lelp My L&1 Workplace Rights Trades & Licensing PERFORMANCE HEATING & A/C INC Owner or tradesperson Principals MILLER, DANIEL E, PRESIDENT ERDAHL, DARRIN, VICE PRESIDENT GOWIN, RICHARD L, VICE PRESIDENT (End: 04/26/2011) GOWIN, CONSTANCE F, VICE PRESIDENT (End: 11/15/2007) Doing business as PERFORMANCE HEATING & A/C INC WA UBI No. 600 601 386 1012 Central Ave S KENT, WA 98032 425-251-0356 KING County Business type Corporation Governing persons DARRIN P. ERDAHL DANIEL E MILLER; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. PERFOHA150RT Effective — expiration 12/30/1985— 04/30/2019 Bond DEVELOPERS SURETY & INDEM CO Bond account no. 748802C $12,000.00 Received by L&I Effective date 11/27/2007 10/01/2007 Expiration date Until Canceled Insurance Charter Oak Fire Ins Co $1,000,000.00 Policy no. DTC03J659957C0F17 Received by L&I Effective date 04118/2017 04/28/2017 Expiration date 04/28/2018 Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=600601386&LIC=PERFOHA15ORT&SAW= 2/14/2018 INSTALL NEW UNIT MOUNT ON EXISTING SLEEPERS REUSE DISCONNECT, RECONNECT EXISTING WIRING VERIFY FUSES, ENSURE FUSE SIZE MATCHES MOCP ON SCHEDULE RECONNECT TO EXISTING LOW -VOLTAGE THERMOSTAT WIRING PATCH AND SEAL ROOF AT ATTACHMENT POINTS OF NEW UNIT NEW SHEET METAL FITTINGS TO CONNECT TO EXISTING DUCTWORK FIELD COORDINATE SIZE AND LOCATION RTU -1 ZX 147'-1" ROOF PARTIAL PLAN SCALE: 1/16"= l'-0" ( j ....<.. S3 e. � .. vY. e- ..L 2. �"' �� K �..1 , ..%� �.. ;,�, ,,> � � ,, ., ¢ �C . e <,. ,�, e ... " z � ; ., tik6:3 'ii. ;d' .A, T > `�.. b5 a ,"'H�;# 5h ,`3 yi1SY� X, �7 vye slvG ry , $ f „e+w A �'. � � �r.{��a'f /�1 � �}��' f'e .4 ,%;a yx/rkN i5 � y� vf.,,,ir�� `9 I i:R �`i !; e `'�"' s �2 :'rkk�/rl S'&y I,'r. ? � YyY. f �,u,,, 3z��'Yxt.ee .e�� rx f ,,d .E 3�k3. l ,i,m'� yY r' d,;! ShZ '^F?' 3''"'�';Y a 's ,w„",hj"�f,, �.. e , „ T...... Y .. . `Y u. x� ✓ s' ,� � � �1iY(33�3 (�t., 4 sl „ii .£ ,/' � K.... @i. l .•i' � _:.. UNIT HEAT AUX. HEAT ELECTWAL WT NO. MFG & •"I 3 NO TEER LIN COP ESP KW srAcEs OXT/PH I61' LBS WANES RTU -1 CARRIER 50TCQD08 7.5 12.5 / 11.2 85 3.3 3000 600 0.5 15.2 3 460/3 45 1099 1,2,3,4,5,6,7 NOTES: 1. LEVEL UNIT, MOUNT PER STRUCTURAL DETAILS 2. REUSE EXISTING DISCONNECT 3. RECONNECT TO EXISTING GAS PIPING 4. TWO-STAGE COOLING 5. PROVIDE MODULATING ECONOMIZER W/LOW-LEAK DAMPERS 6. RECONNECT TO EXISTING THERMOSTAT 7. UNIT MEETS THE REQUIREMENTS OF C403.2.3(1)A ZONE OF PROPERTY: COMMERCIAL ZONE OF ADJACENT PROPERTY: COMMERCIAL dBA LIMIT: 60 SCOPE OF WORK: REPLACE (1) ROOFTOP UNIT W/ NEW NOTES: 1. THESE PLANS ARE SCHEMATIC AND MAY NOT REFLECT EXACT ROUTING OR OFFSETS. 2. MATERIALS AND METHODS SHALL COMPLY WITH THE 2015 INTERNATIONAL MECHANICAL CODE, INTERNATIONAL BUILDING CODE, AND INTERNATIONAL ARE CODE, AS MODIFIED BY WASHINGTON STATE AND LOCAL JURISDICTIONS. DESIGN CONFORMS TO WASHINGTON STATE ENERGY CODE. 3. DUCTS CONSTRUCTION AND HANGING SHALL CONFORM TO SMACNA STANDARDS. 4. DUCTS ARE INSULATED PER 2015 WASHINGTON STATE ENERGY CODE. 5. ALL EQUIPMENT SHALL BE INSTALLED PER 2015 IMC. EXACT LOCATION AND MOUNTING SHALL BE REFLECTED ON STRUCTURAL PLAN. 6. ALL EQUIPMENT MEETS EFFICIENCY REQUIREMENTS OF 2015 WASHINGTON STATE ENERGY CODE. 7. AIR BALANCING TO BE PROVIDED, ALL FLOWS TO BE BALANCED WITHIN 5% OF DESIGN AIRFLOW. DEVIATIONS OUTSIDE THAT TO BE REPORTED TO DESIGN ENGINEER. 8. COMMISSIONING OF SYSTEMS PER WSEC C408.2 IS REQUIRED. 8.1. PROVIDE NARRATIVE DESCRIPTION OF ACTMTIES, RESPONSIBILITIES OF THE CX TEAM, AND SCHEDULE OF ACTMTIES. 8.2. PROVIDE COMPLIANCE CHECKLIST TO OWNER PRIOR TO FINAL INSPECTION LEGAL INFO ISEPARATE PEP,MIT ► EQUIRED FOR: 0 Mechanical Ele trtcal ErPlumbing i.+ "Gas Piping Ciy of Tukwila DIV!^ I Dynamic Solutions for the Built Environment REVISIONS W No changes shall ho made to the scope of work'withot.±t prior approval of Tukwila Building Division. APN: 352304-9093 NOTE: Revisions will require a now plan subrn :al and may inc'•.!de additional plan rev,nt.' fecs LEGAL DESC: POR OF NW 1/4 OF NE 1/4 OF SEC 35-23-04.TGW POR OF SW 1/4 OF SE 1/4 OF SEC 26-23-04 - BEG NE COR OF NW 1/4 OF NE 1/4 OF SEC 35-23-04 TH N 87-44-08 W ALG N LN OF SD SEC 30 FT TO W MGN OF ANDOVER PARK WEST & TPOB TH S 01-51-39 W ALG SD W MGN 681.34 FT TH N 87-55-02 W 270 FT TH N 01-51-39 E 682.19 FT TH N 01-51-39 E 114.81 FT TH S 87-55-02 E 270 FT TO W MGN OF ANDOVER PARK WEST TH S 01-47-29 W ALG SD W MGN 115.66 FT TO TPOB LESS POR FOR ACCESS RD JOB NOTES: 1. VERIFY LOCATION OF BUILDING RETURN, ENSURE AT LEAST 5 S.F. OF TRANSFER AREA FROM SPACE TO EXISTING FOR RETURN PATH. PROVIDE NEW GRILLE IF NECESSARY. FILE COPY Permit No, I(1\ ( 0co Plan review approval is subject to errors alS2coir .�slon Approval of construction documents dam�t iutf oriz the violation of any adopted coda or ordica e R ;cei of approved Field Copy and c By: Date. l / c/1 FS s. e io,Jls is acknowledged: City of Tukwila RUEL DING DIVISION Baker Blvd 1 64th St Strander Blvd Strander.BVId erreck Dr Ind 1 S170th St 11 mmtipland Dr Tr+land Dr S480tti St r S.180th St S 180th St ;da 80th Aja 8.1 82nd St o 0, .184th St S,1 86th P1 .. ............ SA 88th St 5188th Sti ft, S 190th St S •190th St City B ILDII SITE MAP OO S•190th St Map data ©2018 Google,; Ter stC.rof to iVED CITY OF TUKWILA B 5 2018 PERFEMIT 0 CENTER EVVED FOR .OMPLIANCE ROVED 13 2018 gp- M Tukwila C IVISION MECHANICAL PLANS PARTIAL ROOF PLAN y cc a cc0 1191 ANDOVER PARK WEST TUKWILA WA 98188 DATE: 01/23/2018 DRAWN: KR ENGR: KR APPVD: GI JOB NUMBER: 111034 M-1 1 OF 1