Permit M18-0035 - SOUTHCENTER PLAZA - HEAT PUMPS REPLACEMENT
SOUTHCENTER PLAZA 14900 INTERURBAN AVE S M18-0035 Parcel No: Address: r City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov 3597000006 14900 INTERURBAN AVE S Project Name: SOUTHCENTER PLAZA MECHANICAL PERMIT Permit Number: M18-0035 Issue Date: 3/13/2018 Permit Expires On: 9/9/2018 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: SCHNEIDER & SCHNEIDER LLC 923 POWELL AVE SW STE 101 C/O JSH PROPERTIES INC, RENTON, WA, 98057 JESSE CHUTICH 3202 C ST NE , AUBURN, WA, 98002 COMFORT MECHANICAL INC (CONSTRUCT) 3202 C ST NE , AUBURN, WA, 98002 COMFOM1015LA 1// Phone: (425) 251-9840 Phone: (425) 251-9840 Expiration Date: 4/25/2018 DESCRIPTION OF WORK: REPLACE (1) 4 -TON AND (1) 3 -TON ROOF MOUNTED PACKAGED HEAT PUMPS WITH NEW SAME CAPACITY UNITS Valuation of Work: $13,284.00 Type of Work: REPLACEMENT Fuel type: ELECT Fees Collected: $395.58 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: Date: 2017 2017 2017 2015 18 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Date: 3- )3 - Print 3" Print Name: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: Readily accessible access to roof mounted equipment is required. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: ***MECHANICAL PERMIT CONDITIONS*** 10: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 11: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL r1 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA. goy Project No. Date Application Accepted-. Date Application Expires: (For office u MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION King Co Assessor's Tax No.: 3 S-1 70 0 -000 6 Site Address: 1 qq I O O I n -1 e r u r l> a V Q- S Tenant Name: I -e.Iife,r Pla2,o4.. Suite Number: mor ♦ 12S Floor: Roof .O[ New Tenant: ❑ Yes PROPERTY OWNER Name: Sc11nCde, ah,/ ScJine7D1er /lc Address: 11100 Ihier t -t $4j w#1 cW € City: T.% I 14.. State: A Zip: ei $ / G s CONTACT PERSON — person receiving all project communication Name: Jesse Chutich Address: 3202 C St NE City: Auburn State: WA Zip: 98002 Phone: (425) 251-9840 Fax: Email: jesse@comfortmech.com No MECHANICAL CONTRACTOR INFORMATION Company Name: Comfort Mechanical Inc. Address: 3202 C St NE City: Auburn State: WA Zip: 98002 Phone: (425) 251-9840 Fax: Contr Reg No.: COMFOM1015LA Exp Date: 04/25/2018 Tukwila Business License No.: BUS -0993365 Valuation of project (contractor's bid price): $ l 3 Z O Ll Describe the scope of work in detail: Reel4411- 66'j -+en acid 0) 3. r 4OP+ "r00MO4.nl'py1 tAc-X4 eP) L+ea) Pw*1 I"/' hG S e`✓ S^mGaj� I �r (..rt ' Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement \ i Fuel Type: Electric ... Gas ❑ Other: H:\Applications\Forms-Applications On Line \2016 Applications\Mechanical Permit Application Revised I-4-16.docx Revised: January 2016 bh Page 1 of 2 \ • . • • ♦ 4t 1 Indicate type of mechanical work being installed and the quantity below: \ .. • Unit Type Qty Air handling unit t Furnace <100k btu 2 Furnace >100k btu 55 dB(A) Floor furnace 57 dB(A) Suspended/wall/floor mounted heater Commercial Appliance vent 47 dB(A) ' Repair or addition to heat/refrig/cooling system 65 dB(A) Air handling unit 60 dB(A) <10,000 cfm 65 dB(A) Noise: Unit Type Qty Air handling unit Residential, Nighttime >10,000 cfm Industrial Evaporator cooler 55 dB(A) Ventilation fan connected to single duct 57 dB(A) Ventilation system Commercial Hood and duct 47 dB(A) ' Incinerator — domestic 65 dB(A) Incinerator — comm/industrial 60 dB(A) Unit Type Qty Fire damper Residential, Nighttime Diffuser Industrial Thermostat 55 dB(A) Wood/gas stove 57 dB(A) Emergency generator Commercial Other mechanical equipment 47 dB(A) ' 60 dB(A) 65 dB(A) Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be beard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) ' 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-10PM, Monday through Friday and 8AM-10PM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: • Warning devices; • Construction and property maintenance during the daytime hours (7am-lOpm); • Testing of backup generators during the day. PERMIT APPLICATION NOTES Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE ST4TE OF WASHINGTON, AND I AM AUTHORIZED TO APPLE' FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: 4511 Date: /1E? Print Name: Jesse Chutich Day Telephone: (425) 251-9840 Mailing Address: 3202 C St NE Aburn WA 98002 City State Zip H:\Applications\Fortes-Applications On Line\2016 Applications\Mechanical Permit Application Revised l-4-16.docx Revised: January 2016 bit Page 2 of 2 l 1 Cash Register Receipt City of Tukwila Receipt Number DESCRIPTIONS PermitTRAK ( ACCOUNT I QUANTITY I PAID $395.58 M18-0035 Address: 14900 INTERURBAN AVE S Apn: 3597000006 $395.58 Credit Card Fee $11.52 Credit Card Fee R000.369.908.00.00 0.00 $11.52 MECHANICAL $369.29 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $262.28 PLAN CHECK FEE R000.322.102.00.00 0.00 $73.86 TECHNOLOGY FEE $14.77 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R13918 R000.322.900.04.00 0.00 $14.77 $395.58 Date Paid: Friday, March 02, 2018 Paid By: JESSE CHUTICH Pay Method: CREDIT CARD 612005 Printed: Friday, March 02, 2018 2:50 PM 1 of 1 SYSTEMS f INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 M,1$-0035 Project:,Type .....)(,,,,-1-4/1 69,-\ of Inspection: M,tr „,, ,i - F r,r L Address: At S, Date Called: Iy90cDu,r6an Special Instructions: Date Wanted: �y� �`5-2e)/� qbL-' Requester: Phone No: pproved per applicable codes. Corrections required prior to approval. COMMENTS: MecLw.,,v ( Fist, (4� Inspector: `;7 Date: //_5 -0/s REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. K Job Name: SOUTHCENTER PLAZA Prepared By: COMFORT MECHANICAL INC. Unit Tag:WSC048H3REA33 Quantity: 1 Trane Precedent Heat Pump Packaged Rooftop Unit Overview - WSC0481-1.3REAk*K000A20001.00000000000000000 Application Unit Size External Airflow Static Height DX pooling 4 Ton Pressu � _•a - fe 1600 cfm '0.5001n H2O., ; -3.41 i Low Leak Econ dry bulb 0- reshAirSelection e .. 15100%/bar rel 3p upplyFanlDnve/ MotorType Standard drive motor," " !anets/Fitters Standard panelslstd filters Unit Electrical Cooling Section Unit Controls Standard dnif controls '. ain munications Option Without communications stem Monitonng Controls 1; Without monitonng;controis. ,,ystem Monitoring Controls2,INo monitoring controls Entering,Dry BuIb80.00 F' ntering Wet Bulb 67 00 F mbientTemp, 95 00 F' eaving Coiidry BuIb:56 39 F eaving Coil liyet Bulb' 56.30 F eaving Unit Dry Bulb 58.67;;F '. Leaving Unit Wet Bu1b.57 38 F, Heating Section cross Total 49 95 MBh.; ross Sensible,38 45 MBfi,"` et Totai,!48 54 Jet Sensible,. 37.04 Fan Motor Heat,0 55; RefrigaCharge-circuit 1, 9.3 Ib_ R NCE 2HgatType: Electric Heating Stages; 2 utput I !eating, Capacity 47 08 MBfi Heating EAT, 70 00 ..F.;;•••• ; Heating Temp Rise 27 08 F `. Fan Section Type;Propeller . an Quantity 1 Drive Type Direct, ondenser Fan FLA rflow 1600 cfm ` esign ESP„ 0'500 in H2O; omponent,SP 0.130 in H2O Total SP 0.680 m H2O oor Motor Operating; Power Or ,p I ndoor Se94-1' •- I K�a�J', 2018-02-06 00:26:04Z i:ala 0 2 2018 OW' 140.A Type FC Centrifugal "e Type Direct x s as haust Fan'Power 0.25 kW iaust Fan FLA 6.90 A PERMIT CENTER UpPilliqiii Page 1 of 12 er Compressor Section 2018-02-08 00:28:04Z Job Name:SOUTHCENTER PLAZA Prepared By: COMFORT MECHANICAL INC. Unit Tag: WSC048H3REA33 Quantity: 1 ower: 3.52 kW. rcuft 1 RI.A 14 50 A ircutt 2 RLA0 00 A Page 2 of 12 Job Name: SOUTHCENTER PLAZA Prepared By: COMFORT MECHANICAL INC. Unit Tag: WSC048H3REA33 Quantity: 1 EVAPORATOR SECTION ACCESS PANEL TOP PANEL CONDENSER FAN CONDENSATE DRAIN (ALT) 3/4"-14 NPT DIA. HOLE 4 1/4" THROUGH THE BASE 23 9/16" 42 1/4" PLAN VIEW UNIT DIMENSION DRAWING "... SUPPLY 7 143/4" RETURN o 17 1!4" 2018-02-06 00:26:042 r- CONDENSATE 69 7B' 23 114" 43/4" 00 W�f 8 718" I"- 4" 15" ONDENSER COIL UNITCONTROLWIRE 718" DIA. HOLE SERVICE GAUGE PORT ACCESS 1 3/8"DIA. HOLE HIT POWER WIRE ONTROL AND COMPRESSOR ACCESS PANEL SEE NOTE 3 40 PACKAGED H EATP DIMENSION DRAWING HORIZONTAL ALR FLOW Page 3 of 12 7/8" 20 i /4 o t 0 9 5/8" 5518" 0 I 4 = 41!4"-4- 5 9/16"—R� 7 5/5* -- IMP 441/4 DIMENSION DRAWING HORIZONTAL ALR FLOW Page 3 of 12 TRANS' 2018-02-06 00:26:04Z Job Name: SOUTHCENTER PLAZA Prepared By: COMFORT MECHANICAL INC. Unit Tag: WSC048H3REA33 Quantity: 1 jil &liI CONDENSER COIL SIDE PANEL ACCESS SIDE CONDENSER COIL SIDE THROUGH THE BASE ELECTRICAL (SEE NOTE 1) 311/16' THROUGH THE BASE CONDENSATE 4 7/8• 5 1/16" THROUGH THE BASE GAS DHC MODELS ONLY) SEE NOT 1) 27 9/16" NOTES: 1. THRU -THE -BASE ELECTRI CAL ANDIOR GAS IS NOT STANDARD ONALL U NITS. wy 2. VERIFYWEIGHT,CMINE CTION,AND ALL DIMENSION WITH INSTALLER DOCUM ENTS BEFORE INSTALLATION PANEL ACCESS SIDE THRU THE BASE ELECTRICAL PLAN / ISO VIEW DRAWING Page 4 of 12 Job Name: SOUTHCENTER PLAZA Prepared By: COMFORT MECHANICAL INC. Unit Tag: WSCO4BH3REA33 Quantity: 1 ELECTRICAL! GENERAL DATA GENERAL 'PHA WITH HEATER Model: WSC048H Oversized M otor H eater kW Rating : 9.0/120 Unit Operating VOItage: 187-256 MCA N/A Stage: 2 Unit P rim ary Voltage: 208 MFS: N/A td CA: 58.0/63.9 Unit Secondory Voltage: 230 MCB: NIA MFS 50.0/70.0 Unit Hertz 60 ht CB 50.0/70.0 Unit P hose: 3 SEER 12.0/14.0 Standard IA otor Field Installed Oversized M ator Oversized M otor Field Installed Oversized M otor Minimum CircuitAmpacity. 27.0 MCA: N/A MCA NIA MCA: N/A Maximum Fuse Size: 40.0 MFS: N/A MFS: N/A MES: NIA Maximum (HAL R)Circuit Breaker.. 40.0 MCB: N/A MCB: NIA MCB: N/A INDOOR MOTOR Standard 1/star Outsized M otor Field Instated Oversized M otor Number. 1 Number. N/A Number. N/A Motor Speed (RPM): 1.0 Motor Speed (RPM ): NIA MotorSpeed (RPM ): N/A Horsepower: - Horsepower. N/A Horsepower. N/A Phase: 3 Phase: NTA Phase: N/A Full Load Amps: 6.9 Full Load Amps NIA Full Load Amps: N/A Lacked RotorAmps: - Locked RotorAmps: N/A Lolled Rotor Amps: N/A COMPRESSOR Circud 1/2 OUTDOOR MOTOR Number: 1 Number: 1 H arse powe r. 3.8 Horsepower. 0.40 Phase: 3 1/ otor Speed (RPM): 1100 Rated Load Amps: 14.5 Phase: 3 Locked RotorAmps: 98.0 Full Load Am ps: 1.4 Looked RotorAmps 4.6 POWER EXHAUST ACCESSORY (3) FILTERS REFRIGERANT (2) (Field Installed P nyder Exhaust) Type R410 Phase: N/A Type: Throvevey Horsepower: N/A Furnished: Yes FadoryCharge Motor Speed(RPM): N/A Number 2 Circuit/1 9.3 lb Full Load Amps: N/A Recommended 20"x3S'x2" Crcuit#2 NIA Locked RotorAmps: N/A NOTES: 1. rd aximum (HACR )Circuit Breaker sizing is for installations in the United States only. 2. Refrigerant charge is an approximate value. Fora more pre else value, see unit nameplate and service instrudiona 3. Value does not include Power E xitaust Accessory. 4. Value includes oversized motor. 5. Value does not Include Power Exhaust Accessory. ,6. EER is rated at AH RI conditions and insccordance with DOE test procedures. 2018-02-06 00:28:042 Page 5 of 12 Job Name: SOUTHCENTER PLAZA Prepared By: COMFORT MECHANICAL INC. Unit Tag: WSC048H3REA33 Quantity; 1 PACKAGED H EAT PU MP CORNER WEIGHT INSTALLED ACCESSORIES NET WEIGH ACCESSORY WEIGHTS ECONOMIZER 68.D lb M OTORIZED OUTSIDE AIR DAMPER MANUAL OUTSIDE AIR DAMPER BAROMETRIC RELIEF OVERSIZED MOTOR BELT DRIVE MOTOR POWER EXHAUST HEATER 15.0 Ib THROUGH THE BASE ELECTRICAL (FIOPS) 8.0 Ib UNIT MOUNTED CIRCUIT BREAKER (FIOPS) 5.0 Ib UNIT MOUNTED DISCONNECT (FIOPS) POWERED CONVENIENCE OUTLET (FIOPS) HINGED D00RS (FIOPS) HAIL GUARD SMOKE DETECTOR, SUPPLY/ RETURN ROOF CURB BASIC UNIT WEIGHTS CORNER WEIGHTS CENTER OFGRAVITIY SHIPPING N ET 229.018 170.91b (E) LENGHT (F)WIDTH 645.0 lb 540.0 Ib ( �O 68.0 Ib g 1 73.0 18 31' 26' NOTE: 1. CORNER WEIGHTS ARE GIVEN FOR INFORMATION ONLY. Z TO ESTIMATE SHIPPING WEIGHTADD 5 LBS TO NET WEIGHT. 3. BASIC UNIT WEIGHT DOE S N OT INCLUDE ACCESSORY WEIGHT. TO OBTAIN TOTAL WEIGHT,ADD ACCESSORY NET WEIGHT TO BASIC UNIT WEIGHT. 4. WEIGHTS FOR OPTIONS NOT LISTE D ARE e5 LBS. PACKAGED H EAT PUMP RIGGING AND CENTER OF GRAVITY 2018-02-06 00:26:04Z Page 6 of 12 TRANS' 2018-02-06 00:26:04Z Job Name: SOUTHCENTER PLAZA Prepared By: COMFORT MECHANICAL INC. Unit Tag: WSC048H3REA33 Quantity: 1 CLEARANCE 36" CLEARANCE FROM TOP OF UNIT 72' CLEARANCE 48" DOWNFLOW CLEARANCE 36" HORIZONTAL CLEARANCE 18" ROOF OPENING UNIT OUTLINE CLEARANCE 36" PACKAGED HEAT PUMP CLEARANCE 40 68 3116' PACKAGED HEAT PUMP 37" 44 'VT DOWN FLOW TYPICAL ROOF OPENING Page 7 of 12 Job Name: SOUTHCENTER PLAZA Prepared By: COMFORT MECHANICAL INC. Unit Tag: WSC048H3REA33 Quantity: 1 NN—ECONOMIZER HOOD BAROMETRIC RELIEF H000 CONOMIZER HOOD 29' LOW LEAK ECONOMIZER HOOD ACCESSORY 2018-02-06 00:26:04Z Page 8 of 12 Job Name: SOUTHCENTER PLAZA Prepared By: COMFORT MECHANICAL INC. Unit Tag: WSC048H3REA33 Quantity: 1 ZONE SENSOR WIRE TABLE WIRE SIZE MAXIMU M WIRE LENGTH 22 GAUGE 20. GAUGE 18 GAUGE 18 GAUGE 14 GAUGE NOTE: 1.AP Wring and devices shovm dashed to be supplied and installed by the customer inaccordance with national and local electrical codes. 2- Low voltage control wiring must not be run In conduit with povervAring. 2018-02-06 00:26:042 1800' 3000' 4500' 7200" 11700' Page 9 of 12 — hill li li L J' / n V V 0 ZONE SENSOR WIRE TABLE WIRE SIZE MAXIMU M WIRE LENGTH 22 GAUGE 20. GAUGE 18 GAUGE 18 GAUGE 14 GAUGE NOTE: 1.AP Wring and devices shovm dashed to be supplied and installed by the customer inaccordance with national and local electrical codes. 2- Low voltage control wiring must not be run In conduit with povervAring. 2018-02-06 00:26:042 1800' 3000' 4500' 7200" 11700' Page 9 of 12 TRAM' Job Name: SOUTHCENTER PLAZA Prepared By: COMFORT MECHANICAL INC. Unit Tag: WSC048H3REA33 Quantity: 1 General The units shall be convertible airflow. The operating range shall be between 115°F and 0°F in cooling as standard from the factory for units with microprocessor controls. Cooling performance shall be rated in accordance with ARI testing procedures. All units shall be factory assembled, internally wired, fully charged with R -410A, and 100 percent run tested to check cooling operation, fan and blower rotation, and control sequence before leaving the factory. Wiring internal to the unit shall be colored and numbered for simplified identification. Units shall be cULus listed and labeled, classified in accordance for Central Cooling Air Conditioners. Case Unit casing shall be constructed of zinc coated, heavy gauge, and galvanized steel. Exterior surfaces shall be cleaned, phosphatized, and finished with a weather -resistant baked enamel finish. Unit's surface shall be tested 672 hours in a salt spray test in compliance with ASTM B117. Cabinet construction shall allow for all maintenance on one side of the unit. AH exposed vertical panels and top covers in the indoor air section shall be insulated with a cleanable foil -faced, fire -retardant permanent, odorless glass fiber material. All insulation edges shall be either captured or sealed. The unit's base pan shall have no penetrations within the perimeter of the curb other than the raised 1 1/8" high downflow supply/return openings to provide an added water integrity precaution, if the condensate drain backs up. The base of the unit shall have provisions for forklift and crane lifting, with forklift capabilities on three sides of the unit. Unit Top The top cover shall be one piece construction or, where seams exist, it shall be double -hemmed and gasket -sealed. The ribbed top adds extra strength and enhances water removal from unit top. Filters 2", throwaway filters shall be standard on 3-5 ton gas electric / cooling only standard efficiency units.2", throwaway filters shall be standard on all 6-10 Ton standard efficiency units and all high efficiency gas electric / cooling units. 2", throwaway filters shall also be standard on all 3-10 ton heat pumps. Compressors All units shall have direct -drive, hermetic, scroll type compressors with centrifugal type oil pumps. Motor shall be suction gas-cooled and shall have a voltage utilization range of plus or minus 10 percent of unit nameplate voltage. Internal overloads shall be provided with the scroll compressors. Notes: Crankcase heaters are only available as option on WSC036E, WSC048E1,&WSC060E1. CCH are standard on all other units Refrigerant Circuits Service pressure ports, and refrigerant line filter driers are factory -installed as standard. An area shall be provided for replacement suction line driers. Evaporator and Condenser Coils Internally finned, 5/16"copper tubes mechanically bonded to a configured aluminum plate fin shall be standard. Coils shall be leak tested at the factory to ensure the pressure integrity. The evaporator coil and condenser coil shall be leak tested to 650 psig and pressure tested to 450 psig. The condenser coil shall have a patent pending 1+1+1 hybrid coil designed with slight gaps for ease of cleaning. A removable, reversible, double -sloped condensate drain pan with through the base condensate drain is standard. 2018-02-06 00:26:04Z Page 10 of 12 Job Name: SOUTHCENTER PLAZA Prepared By: COMFORT MECHANICAL INC. Unit Tag: WSC048H3REA33 Quantity: 1 Outdoor Fans The outdoor fan shall be direct -drive, statically and dynamically balanced, draw -through in the vertical discharge position. The fan motor shall be permanently lubricated and shall have built-in thermal overload protection. Indoor Fan Indoor Fan All 6 to 7.5 ton units (standard efficiency) shall have belt drive motors with an adjustable idler -arm assembly for quick -adjustment to fan belts and motor sheaves. All 10 tons have variable speed direct drive motors. All motors shall be thermally protected. All indoor fan motors meet the U.S. Energy Policy Act of 1992 (EPACT). Controls Unit shall be completely factory -wired with necessary controls and contactor pressure lugs or terminal block for power wiring. Unit shall provide an external location for mounting a fused disconnect device. A choice of microprocessor or electromechanical controls shall be available. Microprocessor controls provide for volt control functions. The resident control algorithms shall make all heating, cooling, and/or ventilating decisions in response to electronic signals from sensors measuring indoor and outdoor temperatures. The control algorithm maintains accurate temperature control, minimizes drift from set point, and provides better building comfort. A centralized Microprocessor shall provide anti -short cycle timing and time delay between compressors to provide a higher level of machine protection. Phase monitor Phase monitor shall provide 100% protection for motors and compressors against problems caused by phase loss, phase imbalance, and phase reversal. Phase monitor is equipped with an LED that provides an ON or FAULT indicator. There are no field adjustments. The module will automatically reset from a fault condition. Electric Heaters Electric heat modules shall be available for installation within basic unit. Electric heater elements shall be constructed of heavy-duty nickel chromium elements internally delta connected for 240 volt, wye connected for 480 and 600 volt. Staging shall be achieved through ReliaTel. Each heater package shall have automatically reset high limit control operating through heating element contactors. All heaters shall be individually fused from the factory, where required, and shall meet all NEC and CEC requirements when properly installed. Power assemblies shall provide single point connection. Electric heat modules shall be UL listed or CSA certified. Through the Base Electrical Access An electrical service entrance shall be provided allowing electrical access for both control and main power connections inside the curb and through the base of the unit. Option will allow for field installation of liquid -tight conduit and an external field -installed disconnect switch. Through the Base Electrical with Circuit Breaker This option is a thermal magnetic, molded case, HACR Circuit Breaker with provisions for through the base electrical connections. The circuit breaker will be installed in a water tight enclosure in the unit with access through a swinging door. Wiring will be provided from the switch to the unit high voltage terminal block. The circuit breaker will provide overcurrent protection, be sized per NEC and UL guidelines, and be agency recognized by UL/CSA. Frostat This option is to be utilized as a safety device. The Frostat opens when temperatures on the evaporator coil fall below 10°F. The temperature will need to rise to 50°F before closing. This option 2018-02-06 00:28:042 Page 11 of 12 TRANE® TAG: 4WCY4048A-SUB-3D SUBMITTAL 4 Ton Convertible Heat Pump Packaged Units 4WCY4048A3000C PRODUCT SPECIFICATIONS MODEL RATED Volts/PH/Hz Performance Cooling BTUHO Indoor Airflow (CFM) Power Input (KW) EER/SEER (BTU/Watt-Hr.)© Sound Power Rating [r1R(A)]® Performance Heating0 (High Temp.)BTUH Power Input (KW) (Low Temp.) BTUH Power Input (KW) HSPF (BTU / Watt -Hr.)© POWER CONN.—V/Ph/Hz Min. Brch. Cir. Ampacity0 Fuse Size — Max. (amps) Fuse Size — Recmd. (amps) COMPRESSOR Volts/Ph/Hz R I Amps —1 R Amps OUTDOOR COIL — TYPE Rows/F.P.I. Face Area (sq.ft.) Tube Size (in.) Refrigerant Control 4WCY4048A3000C 208-230/3/60 47000 1400 3.97 11.75 / 14.0 73 42500 3.56 27200 3.44 8.0 208-230/3/60 25.3 35 35 SCROLL 208-230/3/60 13.7 /83 SPINE -FIN 2/24 18.01 3/8 EXPANSION VALVE INDOOR COIL — TYPE Rows/F.P.I. Face Area (sq.ft.) Tube Size (in.) Refrigerant Control Drain Conn. Size (in.) OUTDOOR FAN — TYPE Dia. (in.) Drive/No. Speeds CFM @ 0.0 in. w.g.0 Motor — HP/R.P.M. Volts/Ph/Hz F.L Amps/L.R. Amps PLATE FIN 3/15 5.0 3/8 EXPANSION VALVE 3/4 FEMALE NPT PROPELLER 28.2 DIRECT/1 4440 1/4 / 825 230/1/60 1.4 / 3.37 INDOOR FAN — TYPE Dia x Width (in.) Drive/No. Speeds CFM ® 0.0 in. w.g.0 Motor— HP/R.P.M. Volts/Ph/Hz FL Amps/L.R Amos FILTER / FURNISHED Type Recommended Recmd Face Area (sq. ft )0 REFRIGERANT Charge (Ir ) DIMENSIONS Crated (in ) CENTRIFUGAL 10 X 10 DIRECT / VARIABLE SEE FAN PERFORMANCE TABLE 3/4 / VARIABLE 200-230/1/60 6.8 / 6.8 NO THROWAWAY 5.3 R410A 775 HXWXL 47.86 / 47.4 / 61.75 WEIGHT Shipping (lbs.) / Net (lbs.) 607 / 479 0 2012 Trane "Certified in accordance with the Unitary Air -Conditioner Equipment certification program, which is based on AHRI Standard 210/240. Sound Power values are not adjusted for AHRI 270-95 tonal cor- rections. Calculated in accordance with currently prevailing Nat'l Electrical Code. Standard Air — Dry Coil — Outdoor. Standard Air — Wet Coil — Indoor. ':` Rated in accordance with D.O.E. test procedure. Filters must be installed in return air system. Square footages listed are based on 300 f.p.m. face velocity. I1 permanent filters are used size per manufacturer's recommendations with clean resistance of 0.05" W.C. 25.40 Dimensional Data and Weights 18.03 18.29 (23/321 (23/321 14.22 (9/161 SECTION Y -Y TYPICAL (81 SIDES OF UOWNFLOW DUCT OPENINGS 1169.92 146-1/161 A 4 INLET TOP SIDE OUTL4 ET --r NOTE: The view labeled "Bottom Side" represents the Base as viewed looking up from underneath the unit. 2 ST3.96 (22-19/32) ON0ENSATE DRAIN FOR 19.0 (3/4] FEMALE NPT LEFT SIDE FRONT SIDE BOTTOM SIDE 4WCY4042 through 4WCY4060 (1 of 3) Dimensional Data and Weight RECOMMENDED SERVICE CLEARANCE MM/IN. 801(061 0 WITH ECONOMIZER BACK SIDE 304.8 1121 162.0 1301 LEFT SIDE 914.4 1361 1066.8 (421 RIGHT SIDE 609.6 1241 161 FRONT SIDE 162.0 1301 1121 CLEARANCE 10 COMBUSTIBLE MATERIAL MMIIN. 801(061 0 BACK SIDE 25.4 111 LEFT SIDE 152.4 161 RIGHT SIDE 152.4 161 FRONT SIDE 304.8 1121 TOP 914.4 1361 1 359. 9, [14-5/32] 457.20 [18] (INSIDE) 82.16 [3-1/41 24V ENTRY 1 288.42 [11-11/321 225.68 [8-7/8] 82.16 [3-1/4] 381.00 [15] (INSIDE) BOTTOM DUCT OPENINGS • A 4 117.73 [4-5/8] 107.44 [4-7/32] POWER ENTRY 28.58 [I-1/81 DIA. KNOCKOUT -� - 150.30 [5-29/32] RIGHT SIDE POWER ENTRY 28.58 [I -I/8) DIA. KNOCKOUT 34.93 [I-3/81 DIA. KNOCKOUT 50.01 11-31/32] DIA. KNOCKOUT SINGLE POINT ENTRY 34.93 [1-3/8] DIA. KNOCKOUT 50.01 [1-31/32] DIA. KNOCKOUT 62.71 [2-15/32] DIA. KNOCKOUT 4WCY4042 through 4WCY4060 (2 of 3) [9-5/8] 381.00 [151 (INSIDE) 325.49 [12-13/161 457.20 [18] (INSIDE) 3 Dimensional Data and Weights I4 86.25 [3-13/32] SUPPLY 449.02 [17-11/161 (OUTSIDE) 449.02 [17-11./16] (OUTSIDE) 176.07 372.82 [14-11/16] (OUTSIDE) 58.19 329.58 - [2-9/321 [12-31/32] [6-15/16] BACK DUCT OPENINGS 17.78 [II/16] f SECTION X'X TYPICAL (8) SIDES OF SIDEFLOW DUCT OPENINGS r r [ 530.60 120-1/8] X , X 1351,95 153-1/32] (SURFACE AREA( BACK SIDE MODEL HEIGHT MM/IN. APPROX. CORNER WEIGHT - KG/185 SHIPPING WEIGHT 00/L85 TOTAL UNIT WEIGHT KG/LBS CENTER OF GRAVITY MM/IN. A WI W2 W3 W4 8 C 4704042/0480 949.33 (37-3/81 76.2 11681 47.6 (1051 35.8 1791 57,6 11271 275.6 16071 211.3 14191 426.1 116.81 635.0 125.01 41(840488 949.33 137-3/81 78.0 11721 49.4 11091 37.6 1831 59.4 11311 282.5 16231 224.4 14951 426.7 116.81 635.0 (25.01 41(84060 1050.93 141-3/81 18.9 11741 46.7 11031 34.9 1771 59.1 11301 277.8 16721 219.5 14841 414.0 116.31 635.0 125.01 48(14042/0486 949.33 137-3/81 68.9 11521 40.8 190] 30.8 (681 52.2 (1151 275.6 16011 217.5 (4791 414.0 116.31 635.0 125.01 4161Y40488 949.33 137-3/81 78.0 (1721 49.4 11091 37.6 (831 59.4 11311 282.5 16231 224.4 (4951 414.0 (16.31 635.0 125.01 4WCY4060 1050.93 141-3/81 80.3 11711 47.6 11051 35.8 1191 60.8 71341 282.8 (6231 224.5 14951 414.0 116,31 635.0 125.01 4WCZ6048 1050.93 (41-3/81 68.9 (1521 40.8 (90] 30.8 1681 52.2 (1151 275.6 (6071 217.5 14791 414.0 116.31 635.0 (25.01 4WC26060 1050.93 141-3/81 80,3 11771 47.6 11051 35.8 1791 60.8 (1341 282.8 (6231 224.5 14951 414.0 (16.31 635.0 125.01 4WCY4042 through 4WCY4060 (3 of 3) 4 Unit Performance Data Indoor Fan Performance 4WCY4048 Horizontal Airflow 4WCY4048-HOR DIPSWITCH SETTINGS External Static Pressure (in. wg) AIRFLOW SETTING 1 2 3 4 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 350 CFM/TON OFF OFF OFF ON Watts 187 232 264 291 318 347 379 413 446 472 - CFM 1355 1387 1396 1392 1382 1370 1360 1351 1341 1326 - 400 CFM/TON' OFF OFF OFF OFF Watts 315 324 352 389 428 464 498 529 563 606 - CFM 1603 1581 1577 1580 1583 1583 1577 1567 1558 1556 - 450 CFM/TON OFF OFF ON OFF Watts 301 431 507 552 584 615 651 694 739 779 - CFM 1752 1794 1812 1816 1812 1806 1800 1797 1793 1785 - Down Airflow 4WCY4048-DOWN DIPSWITCH SETTINGS External Static Pressure (in. wg) AIRFLOW SETTING 1 2 3 4 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 350 CFM/TON OFF OFF OFF ON Watts 208 254 284 312 343 379 414 437 460 490 - CFM 1337 1393 1398 1388 1383 1390 1399 1384 1380 1370 - 400 CFM/TON` OFF OFF OFF OFF Watts 302 349 386 423 465 509 552 583 599 628 - CFM 1574 1580 1585 1589 1594 1598 1601 1597 1584 1556 - 450 CFM/TON OFF OFF ON OFF Watts 501 523 555 592 631 672 714 760 800 845 - CFM 1847 1823 1817 1818 1820 1819 1817 1820 1815 1810 - Factory Default Setting 5 4WCY4048 AIRFLOW WITH AUXILIARY HEAT (CFM) SWITCH SETTINGS SELECTION NOMINAL AIRFLOW 7 -OFF 8 -OFF LOW 1400 CFM 7 -ON 8 -OFF HIGH 1600 CFM 7 -OFF 8 -ON HIGH 1600 CFM 7 -ON 8 -ON HIGH 1600 CFM BAYHTRV305, 308, 310, 315, 320, 325E Supplementary Electric Heater UNIT MODEL ELECTRIC HEATER MODEL RATED VOLTAGE PHASE AMPS HEATER CAPACITY NO. OF STAGES KW/STAGE MCA MAX FUSE OR HACR CKT BKR SIZE (4) CANADA ONLY MAX. CKT BKR SIZE (5) KW BTUH 1 2 ^W/TCY4036.060A3 BAYHTRV305E 208/240 3 10/12 3.76/5.0 12800/17100 1 3.76/5.0 13/15 15/15 15/15 ^W/TCY4036-060A3 BAYHTRV308E 208/240 3 17/19 6.0/8.0 20500/27300 1 6.0/8.0 21/24 25/25 25/25 ^W/TCY4036-060A3 BAYHTRV310E 208/240 3 21/24 7.5/10.0 25600/34100 1 7.5/10.0 26/30 30/30 30/30 ^W/TCY4036-060A3 BAYHTRV315E 208/240 3 31/36 11.27/15.0 38500/51200 2 7.5/10.0 3.76/5.0 39/45 40/45 40/45 ^W/TCY4048-060A3 BAYHTRV320E 208/240 3 42/48 15.0/20.0 51200/68300 2 7.5/10.0 7.5/10.0 52/60 60/60 60/60 ^W/TCY4048-060A3 BAY HTRV325Ek 208/240 3 52/60 18.78/25.0 64100/85300 2 11.26/15.0 7.5/10.0 65/75 70/80 70/80 BAYSPEK61, 64E Single Power Entry Kit SINGLE POWER ENTRY KIT HEATER MODEL UNIT MODEL , BAYSPEK061 E BAYHTRV305E 4WCY4036-060A3 BAYHTRV308E 4WCY4036-060A3 BAYHTRV31OE 4WCY4036-048A3 BAYSPEK064E BAYHTRV315E 4WCY4036-060A3 BAYHTRV320E 4WCY4048A-060A3 BAYCURB051A Full Perimeter Roof Mounting Curb for *****042-060 The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct, build or modify the items depicted in the drawings. The manufacturer is not responsible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use. C' i CHANNEL SIDE WOOD NAILER 38 7/8 53 1/8 ** 42.00 WITH ECONOMIZER WITH 25% FRESH AIR ACCESSORY SERVICE CLEARANCE DIMENSIONS A B C D WC*/TC* 42.00 36.00 12.00** 24.00 DC*/YC* 42.00 36.00 12.00** 36.00 ** 42.00 WITH ECONOMIZER WITH 25% FRESH AIR ACCESSORY Optional Equipment BAYFLTR101, 201B, 1 " - 2" Filter Rack (Mounts in Filter/Coil Section) Filter BAYACCDOR1A & BAYACCDOR2A Hinged Filter Access Door Replaces Filter/Coil Access Panel The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct, build or modify the items depicted in the drawings. The manufacturer is not respon- sible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use. 8 A Optional Equipment BAYECON101,102A Down Discharge Economizer and Rain Hood (Mounts Over Horizontal Return Air Opening) Economizer rain hood Mist -limi- nator Relief damper Roofcurb HVAC Unit Outside ,dampers / eturn air ampers Required filter kit, order separately Return Duct Economizer Unit Application Models A BAYECON101A 4TC',WC',YC',DC' 018-036 20.125" BAYECON102A 4TC',WC',YC', DC' 042-060 24.375" BAYCON200,201A Horizontal Economizer and Rain Hood The drawings on this page are prepared by the manu- facturer in order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct, build or modify the items depicted in the drawings. The manu- facturer is not responsible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use. Economizer Duct Mixed Air Sensor NGaskets (2) Rain Hood a / � 1.0 Economizer A B C D E F BAYECON200AA 22" 20" 16 7/8" 15 11/16 11 11/16 15 BAYECON201AA 26" 22 21/32" 19" 17 11/16 14 11/16 21-3/8 9 Optional Equipment BAYOSAH001,002A, 25% Outside Air Damper (Replaces Filter/Coil Access Panel) The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct, build or modify the items depicted in the drawings. The manufacturer is not responsible for the unauthorized use of these drawings and expressly disclaims any liability for dam- ages resulting from such unauthorized use. Manual Fresh Air Model Unit Application Models A A C B E C 4YC,WC3018-036 4TC3018-036 4W/T/Y/DCY4024-036 4W/Y/DCZ6036 D BAYOSAH001 4YC, W C3018-036 4TC'3018-036 4W/T/Y/DCY4024-036 4W/Y/DCZ6036 22 7/16" 20 11/16" 12 3/8" 9 3/16" BAYOSAH002 4YC, W C3042-060 4TC'3042-060 4W/T/Y/DCY4042-060 4W/Y/DCZ6048-060 25 3/16" 20 11/16" 12 3/8" 9 3/16" BAYDMPR101,102A, 25% Motorized Outside Air Damper (Mounts Over Horizontal Return AIr Opening) 10 FULLY OPEN FULLY CLOSED 4-- D —+ B Unit Application Models A B C D E BAYDMPR101A 4YC,WC3018-036 4TC3018-036 4W/T/Y/DCY4024-036 4W/Y/DCZ6036 1513/16" 11 13/16" 10 1/4" 111/2" 12 1/4" BAYDMPR102A 4YC,WC3042-060 4TC3042-060 4W/ T/Y/DCY4042-060 4W/Y/DCZ6048-060 18 3/16" 15 1/8" 10 1/4" 11 1/2" 12 1/4" 10 FULLY OPEN FULLY CLOSED 4-- D —+ B Mechanical Specifications General The units shall be horizontal airflow as shipped and convertible 'to downflow. All units shall be factory assembled, piped, internally wired and fully charged with refrigerant.All units shall be factory run tested to check cooling operation, fan and blower rotation and control or TXV se- quence. Units shall be designed to operate at ambient temperatures between 115°F and 55°F in cooling as manufactured. Cooling performance shall be rated in ac- cordance with A.H.R.I. standards. Unit Casing All components shall be mounted in a weather -resistant steel cabinet with an enamel finish. Access panels shall be pro- vided for unit controls and indoor coil and fans. Indoor air section compartment shall be completely insulated with fireproof, permanent, odorless glass fiber material. Knockouts shall be provided for utility and control connections. Drain connections shall be provided to accommodate indoor water runoff. Compressor The compressor shall be hermetically sealed, high efficiency Climatuff® com- pressors. Internal overcurrent and over temperature protection, internal pressure relief shall be standard. Refrigeration System All units shall have TXV in cooling and TXV in heating. Service pressure tap ports, and a refrigerant line filter dryer shall be stan- dard. Indoor Coil Coils shall be internally finned or smooth bore 3/8" copper tubes mechanically bonded to configured aluminum plate fin as standard. Evaporator coil leak and pressure tested to 200 psig; condenser coil tested to 450 psig. Trane 6200 Troup Highway Tyler, TX 75707-9010 Condenser Coil — The Spine FinTMcondenser coil shall be continuously wrapped, corrosion resis- tant all aluminum with minimum brazed joints. This coil is 3/8 inch O.D. seamless aluminum tubing glued to a continuous aluminum fin. Coils are lab tested to withstand 2,000 pounds of pressure per square inch. The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by louvered panels. Indoor Air Fan — Direct -drive, forward - curved, centrifugal wheel in a Composite Vortica® Blower housing. Motor shall have thermal overload protection. Permanently lubricated motor bearings. Motor/blower assembly isolated from unit with rubber mounts. Condenser Fan — Direct -drive, draw thru propeller type. Weather -proofed permanent split capacitor fan motor shall have built-in thermal overload and per- manently lubricated motor bearings. System Controls System controls include condenser fan, evaporator fan and compressor contac- tors. Accessories Roof Curb — The roof curb shall be de- signed to mate with the unit and provide support and complete weathertight instal- lation when properly installed. Adhesive back polyurethane sealing strips shall be provided to ensure an airtight seal be- tween supply and return openings of the curb and unit. The roof curb design allows field fabricated ductwork to be connected directly to the curb. Curb ships knocked down for field assembly, and includes factory -installed wood nailer strips. Electric Heaters — Each heater assem- bly shall include power supply fusing if over 48 amps, automatic resetting limit switches and heat limiters for thermal protection. Heaters shall be provided with polarized plugs for quick connection to unit low voltage wiring. Electric heat mod- ules shall be UL listed. .�i..i CERTIFIED,M www.ahrldlrectory.org Unitary Small HP AHHI Standard 210/240 CefI110sllcneralles011lrwPenlllecOmplele//stem Is ll,led WIWPMPL Single Source Power Entry — This ac- cessory when used with electric heat accessory shall allow single source power connection to unit and heater combina- tion. Single source power entry kits shall have specific matching heater(s). Kit shall include high voltage terminal blocks, fuse blocks and fuses, cut -to -length in- terconnecting wiring, and junction box (if required) to provide power sources with fuse protection as required for both the unit and accessory heater. Kit compo- nents shall install within the unit cabinet in the heater access section. Single source branch power circuit shall be protected and wired in accordance with local codes. Fully Modulating Economizer — This accessory shall be field installed and be composed of the following items: 0-100% fresh air damper, damper drive motor, fixed dry bulb enthalpy control, and low voltage wiring plug for electrical connections. Solid state enthalpy or differential enthalpy con- trol is optional. Economizer operations shall be controlled by the preset position of the enthalpy control. A barometic relief damper shall be standard with the econo- mizer and provide a pressure operated damper that shall be gravity closing and prohibit entrance of outside air on equip- ment "off" cycle. Economizer requires BAYRLAY004A relay kit to interface the economizer to the heat pump. Manual Outside Air Dampers — Rain hood and screen shall be field installed. Suitable for up to 25% outside air. Start Kit — Extra compressor starting ca- pacity for single phase equipment. Control Options Standard Indoor Thermostats — Two stage heating/cooling or one stage heat- ing/cooling thermostats shall be available in either manual or automatic changeover. Programmable Electronic Night Set- back Thermostat — Programmable electronic thermostat shall provide heat- ing setback and cooling setup with 7 -day, programming capability. 1H/1C or 2H/2C models available. ENERGY STAR US Intertek The manufacturer has a policy of continuous product and product data improvement and it reserves the right to change design and s ••1 s •• IS - Prat REVIEWED FOR CODE COMPLIANCE APPROWID MAR 0 8 2018 6,gki.41,14% STRUCTURAL CALCULATIONS Southcenter Plaza RTUs 14900 Interurban South Tukwila, Washington FEBRUARY 27, 2018 ?&nt rT :kilts 07 T h el- 'isiLlfi eta LL4 -TIF? v; 1?7= PREPARED FOR: Comfort Mechanical 3202 C Street NE Auburn, Washington 98002 PREPARED BY: Moore Engineering Group 21902 96th Avenue SE Snohomish, Washington RECEIVED CITY OF TUKWILA PAR 022018 oore PERMIT CENTER Engineering Group Kitt* GENERAL STRUCTURAL NOTES: 1. ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THESE NOTES AND THE INTERNATIONAL BUILDING CODE (IBC), 2015 EDITION. 2. DESIGN LOADING CRITERIA: ROOF LIVE LOAD 25 PSF MECHANICAL UNIT RTU -1 — 806 POUNDS RTU -2 — 798 POUNDS EARTHQUAKE SDS = 0.927 SITE CLASS D to E WIND 110 MPH, EXPOSURE B 3. STRUCTURAL CALCULATIONS AND SKETCHES SHALL BE USED IN CONJUNCTION WITH MECHANICAL DRAWINGS FOR BIDDING AND CONSTRUCTION. CONTRACTOR SHALL VERIFY DIMENSIONS AND CONDITIONS FOR COMPATIBILITY AND SHALL NOTIFY ENGINEER OF ALL DISCREPANCIES PRIOR TO CONSTRUCTION. 4. CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS, MEMBER SIZES AND CONDITIONS PRIOR TO COMMENCING ANY WORK. ALL DIMENSIONS OF EXISTING CONSTRUCTION SHOWN ARE INTENDED AS GUIDELINES ONLY AND MUST BE VERIFIED. THE EXISTING CONDITIONS SHOWN ON THE SKETCHES ARE BASED EITHER ON SITE OBSERVATION, ORIGINAL DRAWINGS OR WERE ASSUMED BASED ON EXPECTED CONDITIONS. IF THE EXISTING CONDITIONS DO NOT CLOSELY MATCH THE CONDITIONS SHOWN ON THE SKETCHES, OR IF THE EXISTING MATERIALS ARE OF QUESTIONABLE OR SUBSTANDARD QUALITY, NOTIFY THE ENGINEER PRIOR TO COMMENCING ANY WORK. 5. CONTRACTOR SHALL PROVIDE TEMPORARY BRACING FOR THE STRUCTURE AND STRUCTURAL COMPONENTS UNTIL ALL FINAL CONNECTIONS HAVE BEEN COMPLETED IN ACCORDANCE WITH THE DRAWINGS. 6. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES REQUIRED FOR THE COMPLETION OF THE WORK. 7. SHEET METAL SCREWS SHALL CONFORM TO THE AMERICAN IRON AND STEEL INSTITUTE (AISI) "SPECIFICATIONS FOR THE DESIGN OF COLD -FORMED STEEL STRUCTURAL MEMBERS". 8. METAL STRAPS FOR ANCHORAGE OF MECHANICAL UNITS SHALL CONFORM TO ASTM A446 GRADE A WITH A MINIMUM YIELD STRESS OF 33 KIPS PER SQUARE INCH. 9. CONNECT THE UNITS TO THE METAL CURB ADAPTERS AND THE METAL CURB ADAPTERS TO THE EXISTING METAL CURBS WITH A MINIMUM OF (3) #12 SHEET METAL SCREWS ON EACH SIDE OF THE UNITS. PLACE ONE SCREW AT 6" TO 8" FROM EACH CORNER OF THE UNITS AND THE THIRD SCREW AT APPROXIMATELY THE MIDDLE OF THE UNITS ON EACH SIDE. 10. AS AN OPTION FOR ANCHORAGE OF THE UNIT, CONNECT THE NEW UNIT TO THE METAL CURB ADAPTER WITH FOUR (4) 18 GAGE x 2" WIDE GALVANIZED METAL STRAPS WITH (3) #12 SHEET METAL SCREWS INTO BOTH THE UNIT AND CURB ADAP I'ER IN EACH CORNER OF THE UNIT ALONG THE LENGTH OF THE UNIT. PLACE THE STRAPS APPROXIMATELY 6" FROM THE CORNER OF THE UNIT. PROJECT DESCRIPTION: The project consists of the replacement of two existing rooftop mechanical units. LOADS: LIVE DEAD DEAD + LIVE WIND SEISMIC Roofing and re -roof 1-1/2" metal deck Steel joists at 6' on -center Insulation MEP Ceiling & Lights Total Dead 110 mph, Exposure B Latitude Longitude Site Class SDs (C) = SDS (D) = SDS = EQUIPMENT Existing RTU -1 Unit 525 Economizer 26 Existing Curb 70 Curb Adapter 100 Total 721 pounds Dimensions Existing RTU -2 Unit 351 Curb 100 Adapter Curb 200 Total 651 pounds Dimensions 4.0 1.7 2.3 1.0 2.0 2.0 13.0 25 PSF 38 PSF 47.469 -122.253 D to E WA DNR 0.975 0.878 0.927 New RTU -1 636 70 100 806 pounds 70"x44"x63" high New RTU -2 479 100 219 798 pounds 60"x46"x59" high Moore Engineering Group PROJECT: SOUTHCENTER PLAZA RTUs ENGR: KWM DATE: 2727/ 18 SCALE: 2(17 SHEET 2/23/2018 Design Maps Summary Report usGs Design Maps Summary Report User -Specified Input Report Title Southcenter Plaza RTU Sat February 24, 2018 01:44:27 UTC Building Code Reference Document 2012/2015 International Building Code (which utilizes USGS hazard data available in 2008) Site Coordinates 47.469°N, 122.253°W Site Soil Classification Site Class D - "Stiff Soil" Risk Category I/II/III USGS-Provided Output Ss = L463 g S1 = 0.546 g SMS = 1.463 g SMi = 0.819 g S°s = 0.975 g SD = 0.546 g For information on how the SS and S1 values above have been calculated from probabilistic (risk -targeted) and deterministic ground motions in the direction of maximum horizontal response, please return to the application and select the "2009 NEHRP" building code reference document. sf3 SpectrJ1t1 Fierioc,1 (sec) 0esIn Res vise Soec:rum _rLT(SeCi Although this information is a product of the U.S. Geological Survey, we provide no warranty, expressed or implied, as to the accuracy of the data contained therein. This tool is not a substitute For technical subject -matter knowledge. https://earthquake.usgs.gov/cn2/designmaps/us/summary.php?template=minimal&latitude=47.469&longitude=-122.253&siteclass=3&riskcategory=0&e... 1/1 2/23/2018 Design Maps Summary Report rirtusGs Design Maps Summary Report User -Specified Input Report Title Southcenter Plaza RTU Sat February 24, 2018 01:44:42 UTC Building Code Reference Document 2012/2015 International Building Code (which utilizes USGS hazard data available in 2008) Site Coordinates 47.469°N, 122.253°W Site Soil Classification Site Class E - "Soft Clay Soil" Risk Category I/II/III o eV411141y USGS-Provided Output Ss = 1.463 g Sl = 0.546 g SMs = 1.316 g SMl = 1.310 g SDs = 0.878 g SDl = 0.874 g For information on how the SS and Si values above have been calculated from probabilistic (risk -targeted) and deterministic ground motions in the direction of maximum horizontal response, please return to the application and select the "2009 NEHRP" building code reference document. #SIC.''FR Rely^.`wise SpcctruTn De -s:91 Response Sport!. um Per rt?a. T (•+ Although this information is a product of the U.S. Geological Survey, we provide no warranty, expressed or implied, as to the accuracy of the data contained therein. This tool is not a substitute for technical subject -matter knowledge. 4(q https://earthquake.usgs.gov/cn2/designmaps/us/summary.php?template=minimal&latitude=47.469&longitude=-122.253&siteclass=4&riskcategory=0&e... 1/1 K ca t op op — i op o &L op 4I P y 3 1? o op op i 1--1IS op op ` op L. 'cjop 3 '' � op op-1— cr- 7� ,,,.., • rt. op sp...„... a • op op GG op op LI $ o op 3 a 1CP op LHO' °p I oP a op op „ op ... op 5 oG op • op op 4 op op op op op a op a r+Vu p qt, a : h i unG.puvwu WAX ROMISCLUI COM r (i; N D " a _N: VZV1d 2131Nd9 1-11.110Gt1q-) r+Vu m� E°) CU CWS Cu- Y 41) l $ } I $ MEINw _ $ 1 1011 8 i 1 ( r 1� $ --1-7-k1 w �_1 )--"L" g Intl Ir 1 $ MINIM $ NI►= 10 $ w 6: , 4 Y ' w w w e w f I a i MMMT a $ w m w w $ I } .)- 4.. wl w w cw¢u w w 2 $ )$ q w w,1 _ C11C.1 -I $ 1 1 : ENW: 522 it .0.1,F11 blIM1 4 VZVld N3Lm HinOS Mita 113 0 ge - a 1 v tli.l.Pir. 811 1 1 lq 14 N; 1 i k iso x ; 1. §,4 $ $ xgia1 i 1 EVx 11 1 ; V W ;014 gg;; P19 R 48 . Ill 11W1/1 ill/le bbkhk8ak 1101ii 11 1 hill !rim - 11101111 1 II!!! 1 bF � big t Mg kWh V,psi!! igi , .1 ei 11 wAil VI � t ill ;y 10 gix k!lPT xtg10/ JOril alq110 1 1;41 lit ;qi 1°11 !111112 ill:;;I! ll:lilt 0,1 IA ! likilp 1111 14;1 01 � TY 1m' lit; 111111 1101111}i 4140 .11 1iv Q Oil !I! iiii0 1 ! ii0i11111 1111"§ � 4 g Qi 111 f 1x1111111 111111ii p A ig '4!It 8o 9 Table 1441— Maximum Unit and Comer Weights (Lbs) And Center of Gravity Dimensions (!n.) Unit MaximumWeights (Lbs)T ComerWeights (Lbs)' C Tons Model No. R-22 Refrigerant 3 THC033A YHC033A THO043A YHC043A THC063A YHCoti3A R -410A Refrigerant TSC036E1, E3, E4, EW 3 YSC036E1, E3, E4, EW WSC036E1, E3, E4, EW TSC048E1, E3, E4, EW 4 YSC048E1, E3, E4, EW WSC048E1, E3, E4, EW TSC060E1, E3, E4, EW 5 YSC060E1, E3, E4, EW WSC060E1, E3, E4, EW 4 5 Shipping Net A B Center of Gravity (In.) D Length Width 566 627 598 669 648 704 464 637 507 577 557 612 140 159 119 139 109 126 96 111 32 32 19. 19 147 167 167 180 124 144 135 151 122 139 130 144 112 127 125 137 31 32 31 32 20 20 19 20 555 607 589 586 rib 636 688 825 480 632 514 511 613 682 157 165 177 167 175 181 163 190 228 122 137 107 129 145 109 142 158 177 95 . 95 113 101 101 115 111 110 114 107 134 117 114 142 119 125 155 163 31 31 29 31 31 29 31 31 38 19 19 20 19 19 20* 19 19 24 Notes: 1. Corner weights are given for information only. 2. Weights are approximate. C-25-4-2.6 4- 7o + ;too Ecc•. r' c rb '{ ,c,,rb 72,( T;24 -6c( Rl=PRCO23-EN CENTER Or GRAVITY �--. LENGTH �---� CENTER OF GRAVITY WIDTH 0 CENTER OF GRAVITY Table W2 — Factory -installed Options Net Weights (1.b02 TIYSC &T/YHC NetWelght Accessory 3-5Tons WSC***E 3-5Tons NetWeight 3-4 Tons STon Economizer 26 Barometric Relief 7 Powered Exhaust — Motorized Outside Air Damper 20 Manual Outside Air Damper 18 Roof Curb ,70— Oversized Motor — Belt Drive Motor' 38 Smoke Detector, Return 7 Smoke Detector, Supply 5 Coil Guards 12 Hinged Doors 10 Powered Convenience Outlet 38 Stainless Steel Heat Exchanger° 4 Through the Base Electrical 8 Through the Base Gas 5 Electric Heaters' 15 Unit Mounted Circuit Breaker 5 Unit Mounted Disconnect 5 NovarControl 8 Dehumidification (Hot Gas Reheat) Coil' 15 Notes: 1. Weights for options not listed are < 51bs. 2. Net weight should be added to unit weight when ordering factoryinstalledaccessories. 3. Applicable to Gas/Electric units only. 4. Applicable to R-22TN unitsonly. 5. Applicable to Cooling and Heat Pump units only. 26- 7 20 16 70 5 38 7 5 12 10 38 8 15' 5 5 5 36 10 30 26 115 8 7 5 20 ,121 38 13 30 5 5 5 87 TRRl11@ Job Narne: SOUTHCENTER PLAZA Prepared By: COMFORT MECHANICAL INC. Unil Tag: WSC045H3REA33 Quenbty: 1 PACKAGED HEAT PUMP CORNER WEIGHT INSTALLED ACCESSORIES NET WEIGHT DATA ACCESSORY WEIGHTS ECONOMIZER 68.0 b MOTORIZED OUTSIDE AIR DAMPER MANUAL OUTSIDE AIR DAMPER BAROMETR1C RELIEF OVERSIZED MOTOR BELT DRIVE MOTOR POWER EXHAUST HEATER 15,0 b THROUGH TTHE BASE ELECTRICAL (FIDPS) 85 b U NIT MOUNTED CIRCUIT BREAKER (FIOP S) 55 b UNIT MOUHIED DISCONNECT (F10 PS) POWERED CONVENIENCE OUTLET (MOPS) ` HINGED DOORS (FIOPS) HAIL GUARD SMOKE DETECTOR, SUPPLY! RETURN ROOF CURB BASIC UNIT WEIGHTS CORNER VIEIGHTS CENTER OF GRAMTIY SHIPPING NET 0 Z24.0 lb 0 1TO.5lb (E) LENGHT , (F) WIDTH oast Ib sato lb O 60.0 Ib 1 D® T3.0 b 31' 20' NOTE: . CORNER WEIGHTS ARE GIVEN FOR INFORMATION ONLY. 2.10 ESTIMATE SHIPPING WEIGHTADO 5LBS T0 NET WEIGHT. i BASIC UNIT WEIGHT DOES NOT INCLUDE ACCESSORY WEIGHT. TO OBTAIN TOTAL WEIGHT,ADD ACCESSORY NET WEIGHTTO BASIC UNIT WEIGHT 4. WEIGHTS FOR OPTIONS NOT LISTED ARE >S LBS. PACKAGED HEAT PUMP RIOGINGAND CENTER OF GRNITY 2018.02.06 00:25:04Z 636 -#- 70 .1- ti too (An;4- C(Arb 4C,�.r1 806 Tro4-r Page 6 of 12 v Job Name: SOUTHCENTER PLAZA 0 Prepared By: COMFORT MECHANICAL INC. Unit Tag: WSC048H3REA33 Quantity: 1 EVAPORATOR SECTION ACCESS PANEL TOP PAN EL Nj RT -L/ -I CONDENSER PAN CONDENSATE DRAIN (ALT) 3/4=14 NPT DIA. HOLE 4 114' TN ROUGH THE BASE 23 9116' 42114' PLAN MEW UNIT DIMENSION DRAWING 2018.02.06 00:26:042 O LADENSER COIL UNIT CONTROL WIRE 7/8'OWA.HOLE ERVICE GAUGE PORT ACCESS 1 3/9" DIA. HOLE NITPOWER WIRE ONTROLAND COMPRESSOR ACCESS PANEL SEE NOTE 3 40 PACKAGED HEATP SUPPLY 14314' RETURN tri 2018.02.06 00:26:042 O LADENSER COIL UNIT CONTROL WIRE 7/8'OWA.HOLE ERVICE GAUGE PORT ACCESS 1 3/9" DIA. HOLE NITPOWER WIRE ONTROLAND COMPRESSOR ACCESS PANEL SEE NOTE 3 40 PACKAGED HEATP DIMENSION DRAWING HORIZONTAL AR FLOV! Page 3 0112 i% 7B' 201/4' 95/6" 5 Sr O,— —MI 41/4` . 9/16` 7 5/8' JMP iii5 11 44114' DIMENSION DRAWING HORIZONTAL AR FLOV! Page 3 0112 i% c/1 L — LSs. ( 1(2S 4 W; roo lbS f�LQO ' 7 (n)<i &4 r6J 6V c.(Arb) ". 76-f i DIMENSIONAL DATA SPACCR PANEL WCC042F AND WCC060F ONLY CORNER POST WCC042 AND 0601 ONLY WCCO18-060F OUTLINE - REAR (ALL DIMENSIONS ARE IN INCHES) EVAPORATOR COIL & BLOWER PANEL CONOENSOR COIL WCC042F AND WCCO60F ONLY HORIZONTAL SUPPLY OPENING DOWNFLOW SUPPLY OPENING HORIZONTAL RETURN OPENING APPEARANCE SURFACE OF SUPPLY & RETURN PANEL TYPICAL CROSS SECTION OF HORIZONTAL SUPPLY & RETURN PERIMETER FLANGES NOTES; 7. SEE DRAWING D729946 FOR ISOMETRIC OUTLINE - FRONT. L & DIMENSIONAL SURFACE ISEE TABLE/ 13 CONDENSATE DRAIN FOR 3/4" FEMALE NPT ECONOMIZER/FILTER ACCESS PANEL DOWNFLOW RETURN OPENING SECT. Y—Y TYPICAL. CROSS SECTION OF DOWNFLOW SUPPLY & RETURN PERIMETER FLANGES MODEL CO WOCI1Tp� I/OTWEfGFtf PIETL85) A 8 C D E F B 1 J K L M N P W1 W2 W3 W4 WCCO18F 68 55 72 87 280 55.1/4 36 25-3/16 18-9/16 11-1/10 64/16 843/16 17 20-1/2 25 17-1/2 10 3 4.7!16 WCCO24F W00030F 77 65 89 105 336 55-114 38 29-3/19 189/16 11-1/16 69/16 8.13/16 17 20-13/16 26.5116 17-1/2 . 10 WDC036F 97 78 65 106 366 19 243/16 WCC042F 84 73 80 104 - 351 "' 18-13/16 24 WC0348F 126 104 127 153 511 64-5/18 45 33-3/8 21-1/16 15-1/16 4.16/16 9-1/8 21-15/16 243/4 20 14 3 3-3/4 WCO064 131 106 132 159 629 24-3/4 29 From Dwg. 210729988 Rey. 4 4 dwg. no. 21X729085 P02 • VI? (9) 4WCY4048A-SUB-3D 4 Ton Convertible Heat Pump Packaged Units 4WCY4048A3000C PRODUCT SPECIFICATIONS MODEL RATED Valls/PH/Hz Performance Cooling BTUHO Indoor Airflow (CFM) Power Input (KW) EER/SEER (BTU/Watt-Hr.)® Snjlnd Power Rating fdR(A)ja Performance Heating()) (High 7emp.)BTUH Power Input (KW) (Low Temp.) BTUH Power Input (KW) HSPF (RTU / Watt-Hr.)0 POWER CONN—V/Ph/Hz Min. Brch. Cir. Ampacity® Fuse Size — Max. (amps) Fuse Size — Recmd. (amps) COMPRESSOR Volts/Ph/Hz R L. Amps —1 R. Amps OUTDOOR COIL — TYPE Rows/F.PJ. Face Area (sq.ft.) Tube Size (in.) Refrigerant Control INDOOR COIL — TYPE Rows/F.P.I. Face Area (sq.ft.) Tube Size (in.) Refrigerant Control Drain Conn. Size (in.) OUTDOOR FAN --TYPE Dia. (in.) Drive/No. Speeds CFM @ 0.0 in. w.g.G Motor — HP/R.P.M. Volts/Ph/Hz F.i . Amps/L.R. Amps 4WCY4048A3000C 208-230/3/60 47000 1400 3.97 11.75 / 14.0 73 42500 3.56 27200 3.44 8,0 208-230/3/60 25,3 35 35 SCROLL 208-230/3/60 13.7 /83 SPINE-F1N 2/24 18.01 3/8 EXPANSION VALVE PLATE FIN 3/15 5.0 3/8 EXPANSION VALVE 3/4 FEMALE NPT PROPELLER 28.2 DIRECT / 1 4440 1/4 / 825 230/1/60 1.4 / 3.37 INDOOR FAN — TYPE Dia x Width (In.) Drive/No, Speeds CFM @ 0.0 in. w.g.0 Motor— HP/R.P.M. Volts/Ph/Hz F.L. Amps/L.R. Amps FILTER /FURNISHED Type Recommended Recmd Face Area (so, ft.)® REFRIGERANT Charge (Ips ) DIMENSIONS Crated (in ) WEIGHT Shipping (lbs.) / Net (lbs.) © 2012 Trane CENTRIFUGAL 10X10 DIRECT /VARIABLE SEE FAN PERFORMANCE TABLE 3/4 / VARIABLE 200-230/1/60 6.8 / 6.8 NO THROWAWAY 5,3 R41OA 7 75 HXWXL 47.86/474/61.75 60 (i' Certified in accordance with the Unitary Air -Conditioner Equipment certification program, which is based on AHR1 Standard 210/240. 0 Sound Power values are not adjusted for AHRI 270-95 tonal cor- rections. Calculated In accordance with currently prevailing Nall Electrical Code. Standard Air — Dry Goll — Outdoor, 0 Standard Air — Wel Coil — Indoor, t.0 Rated in accordance with D,O.E. test procedure. Filters must be installed in return air system. Square footages listed ore based on 300 f.p.m. face velocity. If permanent filters are used size per manufacturer's recommendations with clean resistance of 0.05" W.C. ti76( 4--;10o z CGth+) 6 -vv -t7) ` -Gwri,) -71S lbs //\) RT4 -2 29.40 Dimensional Data and Weights 16 0318.29 1231321 1219321 1.22 I9/161 SECTION Y -Y TYPICAL 181 SIDES OF DOWNRIOW DUCT OPENINGS NOTE: The view labeled "Bottom Side" represents the Base as viewed looking up from underneath the unit. 2 513.96 -{ ON0EN5ATE DRAIN fOR 19.0 13141 MALE RPT 122-19/32) LEFT SIDE INLET TOP SIDE 4 OUTLET ENTER Of GRAVITY FRONT SIDE BOTTOM SIDE 4WCY4O42 through 4WCY4O6O (1 of 3) RT Dimensional Data and Weights 372.82 (14-11/16) (OUTSIDE) SUPPLY 86,25 (3-13/32) 449.02 [17-11/16] (OUTSIDE) RETURN 449.02 (17-11.1167 (OUTSIDE) 176.07 329.58 (12.31/32) (6-15/16) BACK DUCT OPENINGS SECTION X'X TYPICAL (8) SIDES OF SIDEFLOW DUCT OPENINGS 58.19 (2-9/32) 1351.95 (53.7/321 (SURFACE AREA) BACK SIDE 530.60 (20-7/81 )400EL HE1G11) 09(19. APPROX. CORNER 801601 - 8G/LOS 09)20)0 WEIGHT 20/182 TOTAL UNIT WEIGHT (G/LOS CE41(0 00 6688116 II4/111. A WI 82 83 84 8 C 4(904042/0466 949.33 1373/81 16.2 11681 47.6 11051 35.8 119) 57.6 1127) 275.6 10071 217.3 14791 426.7 06.81 635.0 125.0) 47[140488 949.33 137-3/81 78.0 11721 49.4 1109) 31.6 1631 59.4 1131) 882.5 (6231 224.4 1495) 426.7 116.81 635.0 125.01 4TCY1060 1050.93 141.3)81 78.9 1774) 46.7 1103) 34,9 (771 59.1 11)01 277.8 1612) 219,5 1484) 414.0 116.31 635.0 125.01 48C10042/018* 949.33 131.3/61 68.0 1152) 40.6 7901 10.8 1681 52.2 (1151 275.6 (6071 217.5 1479) 414.0 116.3) 635.0 125.01 /89140460 949.33 137.3/81 78.0 11721 49.4 11091 37.6 1631 59.4 1111) 282.5 1623) 224.4 14951 414.0 116.3) 635.0 125.01 48[14060 1050.93 141.3(61 80.3 )i)71 47.6 (105) 35.8 1197 00.8 1134) 282,8 (6231 221.5 14951 411.0 116.31 635.0 125.0) 40906048 1050.93 141-3/81 66.9 1152) 40.8 1901 30.6 168) 52.2 1115) 275.6 16011 217.5 14791 414.0 116.3) 635.0 125.01 48926060 1050.93 (47-3/87 80.3 1111) 41.6 (105) 35.8 1791 00.6 11341 282.8 (623) 224.5 (1951 414.0 (16.31 635.0 129.0) 4WCY4042 through 4WCY4060 (3 of 3) 4 EXISTING UNIT: Field Measure 0 QUOTE: MS09S1-18R0 TAG: LA & 9 EXISTING UNIT: Field Measure 0 QUOTE: MS09S1-18R0 TAG: Jo i 5 4 fR 20019 a__ ig al 7z- gp62l- _ 4DTA (,70 via �j 7.4 I i = C ( reg. SPa(A. .9-0 X7-5 ‘2t. : 7`7�z 77700 9 2"$"( L,1 L- L '24 -4.-- 11.1 T € 71 17e TE6c_ hd nt�c pw Moore Engineering Group PROJECT: ENGR: DATE: g'2 C11 SCALE: 1,cf 1(./ 17 SHEET SOG 6J R' ,Sol 1464(7c),(,.3%c.4 ,L -t. N 43 7 mod or ?-0c ciry(3 j 2 7,A. -6 UA t c viiv Moore Engineering Group PROJECT: GZ- �r��rti-. �� s ENGR: 14i( DATE: 2k 7) /S SCALE: SHEET f PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M18-0035 DATE: 03/05/18 PROJECT NAME: SOUTHCENTER PLAZA SITE ADDRESS: 14900 INTERURBAN AVE S X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: Building Division Public Works SIV1 g 111$ Fire Prevention Structural Planning Division ❑ Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 03/06/18 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 04/03/18 Approved ❑ Approved with Conditions Corrections Required ❑ Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping ❑ PW 0 Staff Initials: 12/18/2013 r \ Home Espanol Contact Safety & Health Claims & Insurance 0 Washington State Department of Labor & Industries Search L&I 4 A Z Index Help My L&t Workplace Rights Trades & Licensing COMFORT MECHANICAL INC Owner or tradesperson Principals JACKSON, SHIRLEY A, PRESIDENT JACKSON, HERB J, VICE PRESIDENT Doing business as COMFORT MECHANICAL INC WA UBI No. 601 954 041 3202 C ST NE AUBURN, WA 98002 425-251-9840 KING County Business type Corporation Governing persons HERB J JACKSON SHIRLEY A JACKSON; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties HeatingNent/Air-Conditioning and Refrig (HVAC/R) License no. COMFOMI015LA Effective — expiration 06/01/1999— 04/25/2018 Bond Lexon Ins Co $6,000.00 Bond account no. 9815017 Received by L&I Effective date 06/04/2012 06/01/2012 Expiration date Until Canceled Bond history Insurance AMCO Ins Co $1,000,000.00 Policy no. ACP3008276478 Received by L&I Effective date 05/24/2017 06/01/2017 Expiration date 06/01/2018 Insurance history Savings Help us improve No savings accounts during the previous 6,period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts ......................... No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID 973,224-00 Account is current. Doing business as COMFORT MECHANICAL INC Estimated workers reported Quarter 4 of Year 2017 "11 to 20 Workers" L&I account contact T3 / KENT ANDERSON (360)902-6963 - Email: ANDN235@Ini.wa.gov Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 10/16/2012 Inspection no. 316456144 Location 444 Valley Mall Parkway East Wenatchee, WA 98802 Violations Washington State Dept. of Labor & industries. Jse of this site is subject to the laws of the state of Washington. Help us improve Parcel Number. 359700-0006 SCHNEIDER & SCHNEIDER LLC. 14900 INTERURBAN AVE S 98168 INTERURBAN ADD TO SEATTLE POR SD TR 1 LY SLY OF LN WCH EXTENDS NELY PRPDIC WITH WLY LN OF SD TR FR PT ON SD WLY LN WCH IS 685 FT SELY FR NW COR OF SD TR & LY NLY OF LN WCH EXTENDS NELY PRPDIC WITH WLY LN OF. SD TR FR A PT ON SD WLY LN WCH IS 1565 FT SELY FR NW COR SD TR TGW POR VAC PSE RIW LY SELY OF S 149TH ST AS CONV BY PSP & L TO TUKWILA UNDER AUD NO 6557639 10=25-65 & LY NWLY OF LN WCH EXTENDS SWLY PRPDIC WITH ELY LN OF SD PSE RNV WCH IS ALSO WLY LN OF SD TR 1 FR PT ON SD WLY LN WCH IS 1565 FT SELY FR NW COR SD TR; EXC PORTION CONVEYED TO CITY OF TUKWILA FOR RIGHT-OF-WAY BY DEED UNDER RECORDING NO 20130804001531 PROJECT DESCRIPTION: ( ) 1REPLACE (1) 4-TONAND 1 3.5 -TON ROOF MOUNTED . PACKAGED _ ED HEAT PUMPS WITH NEW 4 -TON AND 3.5 TON ROOF MOUNTED PACKAGED. HEAT PUMPS WITH ECONOMIZERS. GENERAL NOTES: 1. ECONOMIZERS TO PROVIDE 100% OUTSIDE AIR WITH PARTIAL COOLING AND MULTIPLE COOLING STAGES. 2 NO MODIFICATIONS TO EXISTING STRUCTURE PER STRUCTURAL CALCS. 3. ANCHORAGE: (3) #10 SMS PER SIDE. 4, THERMOSTATS TO PROVIDE MINIMUM 5° DEADBAND. 5.7 -DAY PROGRAMMABLE THERMOSTATS WITH LOCKOUT. 6. INSTALL GFCi OUTLET WITHIN 25' OF UNIT. 7. PROVIDE COMMISSIONING REPORT. R Tt'r NS -"1 No changes shall by rnar]e to the scope I of work withal it prior approval of Tukwila Building Division: NOTE: a Vis oris will require a new plan submittal and. may include additional plan review fees. iSEt;r.''..iii: .I„ < J f4;7170 aF^� r �J FOR: I /^,1_.s 10 fulcchanical tIcctrtcal C1lumbing as Piping City of Ttakwira plill-!ill'dG DIVISION • 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 Mechanical Summary MECH-SUM 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised January 2017 Project Information Project Title:. ": SOUTHCENTER PLAZA Date 1/1/2015 Applicant Information. Provide contact information for individual who can respond to Inquiries about compliance form information provided.... For Building Dept. Use Company Name: COMFORT MECHANICAL Company Address: 3202 C ST NE AUBURN, WA 98002 Applicant Name: JESSE CHUTICH Applicant Phone: 425 251 9840 Project Description Briefly describe mechanical systems in the text box provided 0.58 ❑ No System Changes IN New Build•ng 1 Building Addition i1 Tenant Improvement : 4 System Retrofit REPLACE (2) ROOFTOP HVAC UNITS WITH NEW SAME CAPACITY UNITS. ` 1 Total Bldg Performance (TBP) This path includes all mandatory provisions per C401.2 Option 2. ; MECH-SUM, MECH-CHK, and C407 Energy Analysis forms required.. Design Load Calculations heating, cooling or includes all applicable i1 Load calculation summary . MECH-LOAD-CALC Form Provide design load calculations for all mechanical systems and equipment serving the building ventilati'7g needs. if a load calculation summary is provided with the permit documents that compliance Information then the MECH-LOAD-CALC form Is not required. Mechanical Schedules forms are not required, El Mechanical Plans ■ MECH-EQ Fortes (TBD) Indicate location of equipment compliance information. If provided on plans then MECH-EQ however, Include on plans all applicable compliance information listed In MECH-EQ tables. Dedicated Outdoor Air System Requirements and High Efficiency VAV Alternate fire station occupancies) air in a manner that does heating or cooling is required. Exception 1) of DOAS (C403.6, Exception library or fire station) C402.4.1.4 with 100% of • DOAS is required per C403.6 effective July 1, 2017 (office, retail, education, library and All occupied, conditioned areas shall be served by a DOAS that delivers required ventilation not require space conditioning fan operation. Space conditioning fans cycled off when no 1 Ventilation provided via natural ventilation per 2015 IMC in lieu of DOAS (C403.6, NI Ventilation and space conditioning provided by a HEVAV system per C403.7 In lieu 2). 1 DOAS Included in project, although not required (occupancy not office, retail, education, 1 DOAS related allowances included in project: 1 Prescriptive vertical fenestration maximum area allowance increased to 40% per conditioned floor area in building served by DOAS. ❑ Exception to air economizer per C403.3 Exception 1, include MECH-ECONO form. Fan Power exceeds 5hp. 5 horsepower threshold. El Pro ect includes HVAC air distribution systems that provide heating and/or cooling If yes, provide a MECH-FANSYS -SUM form. • For one or more systems, the total fan motor nameplate hp of all fans in HVAC system If yes, provide a seperate MECH-FANSYS form for each HVAC system exceeding the Refer to Section C403.2.11 and MECH-FANSYS-DOC for requirements and exceptions. HVAC Hydronic Systems I. Hydronic chilled water 0 Water -loop heat pump 1 No hydronfc systems 1 Hydronic heating water 0 Geothermal C406 Additional Efficiency Options - Mechanical or air -to -water heat be 15% more efficient than have FEQ z 71 and must be required ventilation alr In a annual hot water energy use be 1 C406.2 More efficient HVAC equipment and fan systems Requires 90% of heating and cooling capacity to be equipment listed in tables C403.2.3(1)-(9) pumps and heat recovery chillers. All equipment listed in tables C403.2.3(1)-(7) must minimum requirements. All stand alone supply, return, and exhaust fans over 1hp must selected within 10% of maximum total or static pressure. IiiI 0406.6 Dedicated outdoor air system (DOAS) Requires 90% of conditioned floorarea to be served by a DOAS per C403.6 that delivers manner that does not require space conditioning fan operation. 1 C406.7 Reduced energy in service water heating Requires 90% of floor area be in occupancy types listed in C406.7.1 and that 60% of provided by heat pump, waste heat recovery or solar water -heating systems. FILE COPY Permit No. Pian review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and conditions is acknowledged: ®ate: 3 ~ ! 3 - 15' BUILDING DIVISION 2015 Washington State EnergyCode Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 Mechalnical Fan System1POWer`Allowance MECH-FANSYS-SUM 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised January 2017 Project Title: SOUTHCENTER PLAZA Date :_ 1/1/2015 For Building Dept. Use HVAC Air Distribution System Schedule List all HVAC systems that have the capability to provide heating and/or cooling to the spaces they serve. System or Primary Supply Fan ID Speed Control (Note 1) Description (Note 2) System Total Nameplate HP (Note 3) Fan Power Calculation Required (Note 4) RTU -1 . CV HEAT PUMP 0.58 No RTU -2 CV HEATPUMP 0.25 No Note 1- Constant Volume (CV), Variable Air Volume (VAV), or Hospital/Lab CV system that qualifies for VAV budget per C403.2.11;1 Exception 1. Single zone VAV systems shall comply as CV. Note 2 - Describe system type and list all fans (or groups of fans) associated with the delivery and removal of conditioned air by the system. Include all supply, retum/relief, exhaust and exhaust hoods (>1 hp), make-up air, dedicated outside air (DOAS), booster fans and series fan -powered terminals- VAV parallel fan -powered terminals and economizer relief fans do not need to be included if the fans do not operate at peak conditions. Note 3 - Enter the total nameplate hp of all fans associated with the delivery and removal of conditioned air by the system. Note 4 -This form automatically identifies whethera MECH-FANSYS form is required to demonstrate compliance with the fan power allowance (Yes), or this information is not required because the system has a combined total nameplate motor hp that is 5 hp or less (No). MECH-FANSYS Forms A MECH-FANSYS form shall be provided for each system with total nameplate hp greater than 5 hp- Select (Add Fan System Form) to generate an additional form: Added forms can be deleted with button in cell E32 of the added form. /. :REV I.S..I ONS RECEIVED CITY OF TUKWILA M 11 01.2013. PERMIT CENTER 1 00 CV LU I— U� u„I Q N �C J Z:CSO CC) CO W�� HC Z W �. C.� z 1, _— F— cn DATEt SCALEt DRAWNi CHECKED s. Cap. Heat Cap. Cool SEER Weight 1,600 47,000 50,000 14 540 Sound(bels) 76 Location Roof, RTU -2 Trane 4WCY4048A 3.5 1,400 42,500 47,000 14 479 76 1 - Roof M1 .0 0 0-00 0