Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M18-0037 - KING COUNTY HOUSING AUTHORITY - HEAT/COOL AND VENTILATION SYSTEM
KING COUNTY HOUSING AUTHORITY 700 ANDOVER PARK W MI 8-0037 Parcel No: Address: Project Name: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 2623049124 Permit Number: 700 ANDOVER PARK W KING COUNTY HOUSING AUTHORITY Issue Date: Permit Expires On: M 18-0037 8/20/2018 2/16/2019 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: KC HOUSING AUTH 600 ANDOVER PARK WEST, SEATTLE, WA, 98188 HEATH MAC COY Phone: (206) 315-4395 700 ANDOVER PARK W , TUKWILA, WA, 98188 PETE ALMOND DEVELOPMENT Phone: CONSTRUCTION LLC 207 BROADWAY 300, TACOMA, WA, 98402 PETEAAD91802 Expiration Date: DESCRIPTION OF WORK: ALTERATION OF EXISTING HEATED STORAGE TO OFFICE SPACE. MECHANICAL SYSTEMS TO INCLUDE VRF FOR HEAT/COOL AND ERV FOR VENTILATION. Valuation of Work: $85,000.00 Type of Work: REPLACEMENT Fuel type: ELECT Fees Collected: $1,311.63 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: Date: 2017 2017 2017 2015 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature:� fl�,St ALS) �n, CQ,.� Dater /214 i 8 y Print Name: U AtGL,rd CJP,Ilre-Ak This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: Readily accessible access to roof mounted equipment is required. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: ***MECHANICAL PERMIT CONDITIONS*** 10: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 11: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL CITY OF TUIC Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. !V\.I9." oo')1 Project No. Date Application Accepted: 1 t(O ti Date Application Expires: 1' (p IS (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address: Tenant Name: 700 Andover Park W. Tukila, WA 98188 King County Housing Authority PROPERTY OWNER Name: Heath Mac Coy Name: King County Housing Authority City: Tukwila State: WA Zip: 98188 Address: 700 Andover Park W Email: heathm@kcha.org City: Tukwila State: WA Zip: 98188 CONTACT PERSON — person receiving all project communication Name: Heath Mac Coy Address: 700 Andover Park W. City: Tukwila State: WA Zip: 98188 Phone: (206) 315-4395 Fax: Email: heathm@kcha.org King Co Assessor's Tax No.: Suite Number: Floor: New Tenant: ❑ Yes ❑ .. No MECHANICAL CONTRACTOR INFORMATION Company Name: Ecotope Address: 1917 1st Ave City: Seattle State: WA Zip: 98101 Phone: (206) 322-3753 Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: Valuation of project (contractor's bid price): $ Describe the scope of work in detail: Alteration of existing heated storage to office space. Mechanical systems to include VRF for heat/cool and ERV for ventilation. 85,000 Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement Fuel Type: Electric Gas ❑ Other: H:Applications\Forms-Applications On Line \2016 Applications\vfechanical Permit Application Revised 1-4-16.docx Revised: January 2016 bh Page 1 of 2 rTh Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Residential, Nighttime Furnace >100k btu 11 Floor furnace 7 Suspended/wall/floor mounted heater 57 dB(A) Appliance vent 1 Repair or addition to heat/refrig/cooling system 9 Air handling unit 65 dB(A) <10,000 cfm 60 dB(A) Unit Type Qty Air handling unit Residential, Nighttime >10,000 cfm 11 Evaporator cooler 7 Ventilation fan connected to single duct 57 dB(A) Ventilation system 1 Hood and duct 47 dB(A) Incinerator — domestic 65 dB(A) Incinerator — comm/industrial 60 dB(A) 0 Unit Type Qty Fire damper Residential, Nighttime Diffuser 11 Thermostat 7 Wood/gas stove 57 dB(A) Emergency generator Commercial Other mechanical equipment 47 dB(A) 60 dB(A) 65 dB(A) Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-10PM, Monday through Friday and 8AM-10PM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: • Warning devices; • Construction and property maintenance during the daytime hours (lam -1 Opm); • Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER ►, R TH Signature: Print Name: Mailing Address: GENT: 70° ,ate. ` 7�.,lt e.‘k,-f H:Wpplications\Forms-Applications On Line \2016 Applications\Mechanical Permit Application Revised 1-4-16.docx Revised: January 2016 bh Date: 3<<6.4 Day Telephone: ZOS - 3/5 - Y395 77,kw.11c A/ i City State Zip Page 2 of 2 Page 1 of 2 CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA 0017340000802374464500 Date: 11/06/2018 01:25:32 PM CREDIT CARD SALE VISA CARD NUMBER: **********8721 K TRAN AMOUNT: $69.87 APPROVAL CD: 078912 RECORD #: 000 CLERK ID: Rachelle X {CARDHOLDER'S SIGNATURE} I AGREE TO PAY THE ABOVE TOTAL AMOUNT ACCORDING TO THE CARD ISSUER AGREEMENT (MERCHANT AGREEMENT IF CREDIT VOUCHER) Thank you! Merchant Copy https://classic.convergepay .com/V irtualMerchant/transaction.do?dispatchMethod=printTra... 11/6/2018 / CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA Date: 11/06/2018 01:25:32 PM CREDIT CARD SALE VISA CARD NUMBER: **********8721 K TRAN AMOUNT: $69.87 APPROVAL CD: 078912 RECORD #: 000 CLERK ID: Rachelle Thank you! Customer Copy Page 2 of 2 https : //classic. convergepay. comNirtualMerchant/transaction. do?di spatchMethod=printTra... 11 /6/2018 r � f 1 DESCRIPTIONS ACCOUNT QUANTITY PAID PermitTRAK $69.87 M18-0037 Address: 700 ANDOVER PARK W Apn: 2623049124 $69.87 Credit Card Fee $2.04 Credit Card Fee R000.369.908.00.00 0.00 $ 2.04 MECHANICAL $67.83 ADDITIONAL PLAN REVIEW TOTAL FEES PAID BY RECEIPT: R15776 R000.345.830.00.00 1.00 $67.83 Date Paid: Tuesday, November 06, 2018 Paid By: MICHAEL CUADRA Pay Method: CREDIT CARD 078912 Printed: Tuesday, November 06, 2018 1:25 PM 1 of 1 SYSTEMS Page 1 of 2 CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA 0017340000802374464500 Date: 08/20/2018 12:02:52 PM CREDIT CARD SALE VISA CARD NUMBER: **********8721 K TRAN AMOUNT: $1,065.36 APPROVAL CD: 098726 RECORD #: 000 CLERK ID: Rachelle X {CARDHOLDER'S SIGNATURE} I AGREE TO PAY THE ABOVE TOTAL AMOUNT ACCORDING TO THE CARD ISSUER AGREEMENT (MERCHANT AGREEMENT IF CREDIT VOUCHER) Thank you! Merchant Copy https://classic. convergepay. com/V irtualMerchant/transaction. do?dispatchMethod=printTra... 8/20/2018 Page 2 of 2 CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA Date: 08/20/2018 12:02:52 PM CREDIT CARD SALE VISA CARD NUMBER: **********8721 K TRAN AMOUNT: $1,065.36 APPROVAL CD: 098726 RECORD #: 000 CLERK ID: Rachelle Thank you! Customer Copy https: //classic. convergepay. com/VirtualMerchant/transaction.do?dispatchMethod=printTra... 8/20/2018 J 4, :ash Register}Recei City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $1,065.36 M18-0037 Address: 700 ANDOVER PARK W Apn: 2623049124 $1,065.36 Credit Card Fee $31.03 Credit Card Fee R000.369.908.00.00 0.00 $31.03 MECHANICAL $985.08 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $951.93 TECHNOLOGY FEE $49.25 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R15191 R000.322.900.04.00 0.00 $49.25 $1,065.36 Date Paid: Monday, August 20, 2018 Paid By: MICHAEL CUADRA Pay Method: CREDIT CARD 098726 Printed: Monday, August 20, 2018 12:03 PM 1 of 1 YSTEM5 f\ Cash Register Recei City of Tukwila Receipt Number R14021 R14021 DESCRIPTIONS PermitTRAK ACCOUNT I QUANTITY ( PAID $2,065.61 D18-0076 Address: 700 ANDOVER PARK W Apn: 2623049124 $1,819.34 DEVELOPMENT $1,819.34 PLAN CHECK FEE R000.345.830.00.00 0.00 $1,819.34 M18-0037 Address: 700 ANDOVER PARK W Apn: 2623049124 $246.27 MECHANICAL $246.27 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R14021 R000.322.102.00.00 0.00 $246.27 $2,065.61 Date Paid: Friday, March 16, 2018 Paid By: KC HOUSING AUTH Pay Method: CHECK 314819 Printed: Friday, March 16, 2018 12:49 PM 1 of 1 f'+. SYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 141 lb PV37 Project: f' - - I Type of Inspection: Address: "709 ANAOtA 1 Date Called: Special Instructions: Date Wanted: /^ 75‘ p.m. Requester: Phone No: pproved per applicable codes. Corrections required prior to approval. OMMENTS: *0-FFA5r/026 Inspector: Date: i - REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 'M -003 Project: K�►2 Lbun 1454,,,y ,t , Type of Inspection: Meckaln;cAL RivAL Add s: pecial Instructions: Date Wanted: - Z Z - 20/ 5 a.m. p.m. Requester Phone No: /-251421) 7 75-5- ❑ Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: scrvloitIt7 ki-d94 Date: REINSPECTIO FEE REQUIRED. Prior to next inspection. fee must be Inspector: paid at 6300 Southcenter Btvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 (fll a? -7 Pro ect: /' /�/(/ jAuv /IoJ%J/1 Type off Insp ctiioln:: (.444-- Address: -709 hovic : 1,4) Date Date Called: _ Instructions: Date Wanted:I "11 m„ p.m. Requester: Phone No: pproved per applicable codes. EJ Corrections required prior to approval. MMENTS: 43054L -At, -V, '' `Q 47 - ns pector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pr j fir. C 1 r +of I spe : - I � leC[I •� Il ►L•l�._l� rens: a ii 4 1 eefte li l CAL Date V ed: pecialfr, structions: Date Wanted: 11- 7-2-j/8 a.m. p.m. Requester: Phone No: Approved per applicable codes. XLl Corrections required prior to approval. OMMENTS: Aprvd (A14/ orr /1,541 �-t44(flI S 1-Q4✓vP 4711,001-s- 114; )(a-- to rkvsLAWe Inspector: XaeCiLL___ Date j/_ 7_ oiP REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. KING COUNTY HOUSING AUTHORITY 700 ANDOVER PARK W I REVIEWED FOR CODE COMPLIANCE APPROVED APR 11 2018 BUILDof Tukwila ING DIVISION MECHANICAL SPECIFICATIONS: HEATING SIZING WORKSHEET MECHANICAL SYSTEMS WORKSHEET ZaS RECEIVED CITY OF TUKWILA MAR 3 0 2018 PERMIT CENTER CCRR CTN LTR#. rDepartment of Planning and Development SEATTLE ENERGY CODE instructions: Jee reverse Project Address: 700 ADOVER PARK WEST TUKWILA. WA 98188 Date of this submittal 2/23/2018 Project Number: Permit Number: HEATING EQPMT SIZING - OFFICE January 2011 Building Component Description Including U -Factor or F -Factor Heat Loss Factor (HLF = U x 46°At) (1) Component Square Feet (SF) Linear Feet (LF) Cubic Feet (CF) (2) Component Heat Loss (HLF x SF, LF or CF) A. Window, Glass Block Single, uncertified (U = 1.20 ) Double, uncertified (U = 0.92 ) 55.2 /SF x SF = 42.3 /SF x SF = Btuh Btuh Sliding & Swinging NFRC certified (U = 0.32 ) 14.7 /SF x SF = Btuh Glass Door NFRC certified (U = 0.30 ) 13.8 /SF x 96 SF = 1325 Btuh Skylight Skylight, single, uncertified (U = 1.58 ) 72.7 ISF x SF = Btuh Garden Window Skylight, double, uncertified (U = 1.05 ) 48.3 /SF x SF = ................... Btuh Skylight, NFRC certified (U = 0.50 ) 23.0 ISF x SF = Btuh Garden window, single, uncertified (U = 2.60 ) 119.6 ISF x SF = Btuh Garden window, double, uncertified (U = 1.81 ) ................. 83.3 /SF x SF = Btuh Other _STOREFRONT (U = 0.38 ) 17.5 /SF x 190 SF = 3321 Btuh Other (U = ) /SF x SF = Btuh B. Opaque Door Wood, in wood frame, uncertified (U = 0.46 ) 21.2 /SF x SF = Btuh Foam ins., in metal frame, uncertified (U = 0.37 ) 17.0 ISF x SF = Btuh Foam ins., in wood frame, uncertified (U = 0.16 ) 7.4 /SF x ............. SF = Btuh Opaque door, NFRC certified (U = 0.20 ) 9.2 /SF x SF = Btuh Other (U = ) /SF x SF = Btuh C. Roof/Ceiling None (U = 0.400 ) 18.4 /SF x SF = Btuh Insulation R-38 (U = 0.031 ) 1.4 /SF x _ SF = Btuh (OPAQUE area only, does not include R-49 standard or R-38 full depth (U = 0.027 ) R-60 (U = 0.025 ) 1.2 ISF x 3260 SF 1.2 /SF x SF ....................... = = 4049 Btuh Btuh skylight area) R-38+12.5ci (U = 0.019 ) 0.9 /SF x SF = Btuh D. Wall Insulation, above and below None (U = 0.250 ) R-13, wood studs (U = 0.082 ) 11.5 /SF x SF = 3.8 /SF x SF = Btuh Btuh grade R-19, wood studs (U = 0.062 ) 2.9 /SF x SF = Btuh (OPAQUE area only, does not include R-21 cavity + R-10 headers, wood (U = 0.051 ) R-19 cavity + R-5 cont., wood studs (U = 0.046 ) 2.3 /SF x ............. SF = ,,..., 2.1 /SF x SF = Btuh Btuh window & door area) R-11, metal studs (U = 0.132 ) 6.1 /SF x SF = Btuh R-19, metal studs (U = 0.109 ) 5.0 /SF x SF = Btuh R-19 cavity + R-8.5 cont., metal stu (U = 0.057 ) 2.6 ISF x SF = Btuh R-13 cavity + R-10 cont., metal studs (U = 0.055 ) 2.5 /SF x SF = Btuh R-_5+12.5ci_ (U = 0.045 ) 2.1 ISF x 1558 SF = 3225 Btuh E. Floor Over None (U = 0.134 ) 6.2 /SF x .,...,. SF = Btuh Unheated Space R-19 (U = 0.041 ) 1.9 /SF x SF = Btuh R-30 (U = 0.029 ) 1.3 /SF x SF = ........ Btuh R-38 (U = 0.025 ) 1.2 /SF x SF = Btuh R-38 Floor over exposed (U = 0.034 ) 1.6 ISF x SF = Btuh F. Slab On Grade Floor None (F = 0.730 ) 33.6 /LF x 112 LF = 3761 Btuh Perimeter Insulation R-10 (F = 0.540 ) 24.8 /LF x LF = Btuh (use linear ft, NOT sq.ft.) R- (F = ) G. Basement Floor None (F = 0.460 ) 21.2 /LF x .................LF = Btuh (for heated space ONLY) R-_ (F = ) /LF x LF = Btuh H. Infiltration Pre -1980 (.018 x 1.2 ACH) 1.0 /CF x CF = Btuh (use cubic ft, NOT sq.ft.) 1980-2010 (.018 x 0.6 ACH) 0.5 ICF x 45640 CF = 22820 Btuh Post -2010 (.018 x 0.35 ACH) 0.3 ICF x CF = Btuh (4) DHL/SF: DHL divided by( 2400 Heated floor area in SF) (3) Total = Design Heating Load (DHL) in Btuh ........................... = 38501 Btuh = 16 Btuh/SF or 4.7 Watts/SF If electric, divide by 3.413 for DHL in watts (Typical values for DHL/SF for new construction are 8 Btuh/SF or 2.5 Watts/SF.) = 11281 Watts .......................................... (5) Space Heating Equipment Sizing Limits (6) Proposed Space Heating Equipment Minimum required size = DHL x 1.0 = 38501 Btuh or 11281 Watts Manufacturer: Model #: Maximum allowed size = DHL x 1.5 = 57751 Btuh or 16921 Watts Heating output: Btuh Efficiency AFUE Watts HSPF 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 Mechanical Summary MECH-SUM Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised January 2017 2015 Washington State Energy Code Compliance Project Information Project Title: 700 BUILDING OFFICE SPACE RENOVATION Date 2/23/2018 Applicant Information. Provide contact information for individual who can respond to inquiries about compliance form information provided. For Building Dept. Use Company Name: KING COUNTY HOUSING AUTHORITY Company Address: 700 ADOVER PARK WEST TUKWILA, WA 98188 Applicant Name: Applicant Phone: Project Description Briefly describe mechanical systems in the text box provided ❑ New Building 1 Building Addition El Tenant Improvement ❑ System Retrofit 1 No System Changes II Total Bldg Performance (TBP) This path includes all mandatory provisions per C401.2 Option 2. MECH-SUM, MECH-CHK, and C407 Energy Analysis forms required. Design Load Calculations building heating, cooling or includes all applicable 1 Load calculation summary ✓ MECH-LOAD-CALC Form Provide design load calculations for all mechanical systems and equipment serving the ventilating needs. If a load calculation summary is provided with the permit documents that compliance information then the MECH-LOAD-CALC form is not required. Mechanical Schedules forms are not required, ✓ Mechanical Plans ❑ MECH-EQ Forms (TBD) Indicate location of equipment compliance information. If provided on plans then MECH-EQ however, include on plans all applicable compliance information listed in MECH-EQ tables. Dedicated Outdoor Air System Requirements and High Efficiency VAV Alternate and fire station occupancies) air in a manner that does heating or cooling is required. Exception 1) lieu of DOAS (C403.6, Exception library or fire station) C402.4.1.4 with 100% of ✓ DOAS is required per C403.6 effective July 1, 2017 (office, retail, education, library All occupied, conditioned areas shall be served by a DOAS that delivers required ventilation not require space conditioning fan operation. Space conditioning fans cycled off when no ❑ Ventilation provided via natural ventilation per 2015 IMC in lieu of DOAS (C403.6, ❑ V) ntilation and space conditioning provided by a HEVAV system per C403.7 in ❑ DOAS included in project, although not required (occupancy not office, retail, education, ❑ DOAS related allowances included in project: ❑ Prescriptive vertical fenestration maximum area allowance increased to 40% per conditioned floor area in building served by DOAS. 1 Exception to air economizer per C403.3 Exception 1, include MECH-ECONO form. Fan Power ❑ Project includes HVAC air distribution systems that provide heating and/or cooling If yes, provide a MECH-FANSYS -SUM form. ❑ For one or more systems, the total fan motor nameplate hp of all fans in HVAC system exceeds 5hp. If yes, provide a seperate MECH-FANSYS form for each HVAC system exceeding the 5 horsepower threshold. Refer to Section C403.2.11 and MECH-FANSYS-DOC for requirements and exceptions. HVAC Hydronic Systems 1 Hydronic chilled water 1 Water -loop heat pump ✓ No hydronic systems ❑ Hydronic heating water ❑ Geothermal 0406 Additional Efficiency Options - Mechanical or air -to -water heat be 15% more efficient than have FEQ >_ 71 and must be required ventilation air in a of annual hot water energy use ✓ C406.2 More efficient HVAC equipment and fan systems Requires 90% of heating and cooling capacity to be equipment listed in tables C403.2.3(1)-(9) pumps and heat recovery chillers. All equipment listed in tables C403.2.3(1)-(7) must minimum requirements. All stand alone supply, retum, and exhaust fans over 1hp must selected within 10% of maximum total or static pressure. ✓ C406.6 Dedicated outdoor air system (DOAS) Requires 90% of conditioned floor area to be served by a DOAS per C403.6 that delivers manner that does not require space conditioning fan operation. ❑ C406.7 Reduced energy in service water heating Requires 90% of floor area be in occupancy types listed in C406.7.1 and that 60% be provided by heat pump, waste heat recovery or solar water -heating systems. 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 Mechanical Summary, -pg 2 ' • - 1 Buildings including R2 & R3 over 3 stories and all R1 Revised January 2017 2015 Washington State Energy Code Compliance Forms for Commercial Service Water HeatingDedicated Systems Equipment Type (s) ❑ Instantaneous ❑ Heat exchange from space heat boiler or central hot water/steam ❑ On -demand water systems • Hot water heating tank(s) ✓ No service boiler Distribution Type (s) I. Circulation System Commissioning Commissioning is required for: ❑ Mechanical systems per C408.2 ❑ Service water heating systems per C408.4 If required, commissioning shall be performed for all applicable systems regardless of individual equipment capacity. Exceptions to commissioning requirements: ❑ Total output capacity of all mechanical space conditioning systems in the building do not exceed 240,000 Btu/h cooling or 300,000 Btu/h heating. Mechanical systems commissioning not required. ❑ Capacity of largest service water heating system in building does not exceed 200,000 Btu/h. Service water heating systems commissioning not required. Low Energy and Semi -Heated Spaces (Note 6 and 7 Space Type Location in Plan(s) Space(s) Served Area Served, square feet Heating Capacity, Btu/h (Note 4) Cooling Capacity, Btu/it (Note 5) Peak Space Conditioning Capacity, Btu/h-sf Compliance Check Notes Note 4 - Note 5 - Note 6 - Note 7 - Provide total installed heating output capacity of systems serving Low Energy or Semi -Heated space(s) in btuh. Provide total installed cooling capacity of system serving Low Energy space(s) in Btu/h. Not allowed for semi -heated spaces. Enter 0 if no cooling. Refer to Section C402.1.1 Low Energy Building. lntalled peak space conditioning capacity, heating or cooling, may not exceed 3.4 Btu/h*sf. Refer to Section C402.1.1.1 and Semi -Heated Space definition in Chapter 2. Total heating output capacity may not exceed 8 Btu/h*sf. Only systems without electric resistance heating and no cooling are eligible for the wall insulation exception under semi -heated. 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 - Page 3 of 11 Mechanical Permit Plans Checklist MECH-CHK mpliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised January 2017 Project Title: 700 BUILDING OFFICE SPACE RENOVATION Date 2/23/2018 The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the Washington State Energy Code, Commercial Provisions. ApplicableLocation (yes,no,na) Code Section Code Provision Information Required - Must be in permit documents in Documents Building Department Notes Equipment - Sizing, Performance and Type NA C403.1 Exempt process equipment Identify equipment to be used in manufacturing, industrial or commercial processes that do not provide space conditioning; identify provisions applicable to this equipment per C403.1 exception YES C403.2.1 Load calculations Provide load calculations performed per ASHRAE Std 183 or equivalent, using design parameters per C302 and Appendix C; include load adjustments to account for energy recovery M0.01 YES C403.2.2than Equipment and system sizing Indicate that output capacities of heating and cooling equipment and systems are no greater the smallest available equipment size that exceeds the calculated loads; note exceptions taken M0.01 YES C403.2.3 C403.2.3.2 C403..2.3.2 1that HVAC equipment performance requirements (efficiency) Provide equipment schedules on plans or complete MECH-EQ forms indicating type, capacity, rated and WSEC minimum efficiencies for all heating and cooling equipment; include supply and OSA cfms and operating hours for all air systems; identify heating and cooling equipment does not have a corresponding WSEC minimum efficiency (manufacturer rated) M0.01 NA C405.8 C403.2.14 Electric motor efficiency List all motors >_ 1/12 hp (that are not integral to a rated piece of equipment) in the mechanical or electrical equipment schedules on pians; indicate hp, rpm, number of poles and rated efficiency, or exception applied For fractional hp motors (1/12 - 1 hp), indicate whether they are an electronically commutated motor, have rated efficiency of at least 70%, or exception taken NA C403.2.11.1 Fan power limitation For all HVAC fan systems that provide heating and / or cooling, provide system total nameplate hp in MECH-FANSYS-SUM form For all applicable HVAC systems with total fan motor hp > 5hp, verify fan system motor hp or bhp complies with fan power limits per equations in Table C403.2.11.1(1), provide MECH- FANSYS form for each system NA C403.2.11.2 Motor nameplate hp For all applicable HVAC systems with total fan motor hp > 5hp, indicate fan motors specified are the smallest available motor hp size greater than fan bhp, note exceptions taken NA C403.2.11.3 Fan efficiencyall For all applicable HVAC systems with total fan motor hp > 5hp, identify in equipment schedule fans required to comply with fan efficiency grade and indicate rated FEG is 5 67, or exception taken; indicate these fans are sized so total efficiency is within 15% of the fan maximum total efficiency NA C403.2.11.4 Group R occupancy exhaust fan efficacy For all exhaust fans < 400 cfm in Group R occupancies. indicate in equipment schedule the fan flow rate and efficacy (cfm/watt), or exception taken; refer to Table C403.2.11.4 (CE -57) NA C403.2.13 Variable flow capacity - fans For fan motors >_ 7.5 hp, indicate method of variable flow control (VSD or equivalent method) in equipment schedule, or exception taken; for equivalent method for an HVAC system refer to HVAC System Controls for additional requirements NA C403.2.3 Maximum air cooled chiller capacity For chilled water plants and buildings with > 500 tons of cooling capacity, indicate air-cooled chiller capacity is <_ 100 tons, or exception taken NA C403.4 Large capacity cooling systems For buildings with >_ 300 tons of cooling capacity, indicate method of multi -stage or variable capacity control (VSD, multiple staged compressors, or max capacity of any single unit < 66% of the total) NA C403.2.3.1 Non-standard water-cooled centrifugal chillers For water-cooled centrifugal chillers not designed for operation at standard conditions, provide calculations documenting maximum full load and part load rated equipment performance requirements NA C403.2.13.1 C403.4.3.2 Centrifugal fan open -circuit cooling towers For open -circuit centrifugal fan cooling towers with >_ 1,100 gpm capacity, indicate cooling towers comply with efficiency requirements for axial fan open circuit cooling towers NA C403.4.2 C403.4.2.5 Large capacity boiler systems For single boilers with > 500,000 Btu/h capacity, indicate multi -stage or moduiating burner For boiler system (single or multiple) with > 1,000,000 Btu/h capacity, indicate turndown ratio per Table C403.4.2.5 and method (multiple single input boilers, modulating boilers, or combination) NA C403.2.13 Variable flow capacity - pumps For pump motors >_ 7.5 hp, indicate method of variable flow control (VSD or equivalent method) in equipment schedule, or exception taken; for equivalent method for a hydronic system refer to Hydronic System Controls for additional requirements NA C403.2.3 Gas and oil -fired forced air furnace and unit heaters For forced air furnaces with capacity > 225,000 Btu/h and all unit heaters, indicate in equipment schedule intermittent ignition or IID, flue or draft damper, and rated jacket loss NA C403.2.4.8 Combustion heating equipment For combustion heating equipment with output capacity > 225,000 Btu/h, indicate modulating or staged combustion control YES C403.2.3.3 Packaged electric heating / cooling equipment Verify all packaged electric equipment with > 6,000 Btu/h cooling capacity and any amount of heating is a heat pump; include in equipment schedules M0.01 NA C403.2.12 Heating outside a building Indicate systems providing heating in non -enclosed outdoor occupied spaces are radiant systems; refer to HVAC System Controls for additional requirements NA C403.2.7.1 Kitchen exhaust hoods Indicate on plans the type, duty and exhaust air rate of each kitchen hood, refer to HVAC System Controls for additional requirements YES C403.2.4.3 Outdoor supply air, exhaust and relief dampers Indicate locations of OSA intake, and exhaust and relief outlet dampers on plans; indicate whether dampers are Class 1 motorized, or gravity and exception taken (include leakage rating, cfm/sf); refer to HVAC System Controls for additional requirements for OSA dampers M1.00/ M0.01 - ERV SCHEDUL No C403.2.4.3 Return air dampers Indicate locations of return air dampers that are integral to economizer operation; verify dampers are motorized; indicate whether dampers are Class 1, or within packaged equipment eligible for leakage rating exception (include leakage rating, cfm/sf) 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 - Page 4 of 11 Mechanical Permit Plans Checklist MECH-CHK mpliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised January 2017 Project Title: 700 BUILDING OFFICE SPACE RENOVATION Date 2/23/2018 The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the Washington State Energy Code, Commercial Provisions. Applicable (yes,no,na) Code Section Code Provision Information Required - Must be in permit documents Location in Documents Building Department Notes NA C403.2.4.3 Stairway and shaft vent dampers Indicate location of stairway and shaft vent dampers on plans; verify dampers are Class 1 motorized; refer to HVAC System Controls for additional requirements NA C403.2.4.4 Zone isolation dampers For systems serving areas > 25,000 sf or spanning more than one floor, that include areas that are expected to be occupied non -simultaneously; identify isolation zone areas on plans and locations of associated isolation dampers in HVAC distribution system; refer to HVAC System Controls for additional requirements NA C403.2.3.4 Humidification For cooling systems with humidification equipment that are also required to have air economizer, indicate humidifier is adiabatic (direct evaporative or fog atomization), or exception taken Additional Efficiency Package Option, More Efficient HVAC Equipment & Fan Performance - Must comply with all 3 provisions to be eligible NA C406.2.1 C403.2.3 HVAC system selection To comply with additional efficiency package option, calculate the percentage of heating and cooling equipment in the project (based on output capacity) that do not have a corresponding WSEC listed efficiency; shall be less than 10% to comply YES C406.2.2 C403.2.3 Minimum equipment efficiency To comply with additional efficiency package option, indicate that all listed heating and cooling equipment have a rated efficiency that exceeds WSEC listed efficiency by at least 15% EC0.01 / M0.01 NA C406.2.3 C403.2.11.3 Minimum fan efficiency To comply with additional efficiency package option, indicate rated FEG of stand alone fans is >_ 71; indicate these fans are sized so the fan efficiency at design conditions is within 10% of the maximum total or static efficiency HVAC System Controls YES C403.2.4.1 Thermostatic controls (thermostats and humidistats) Indicate locations of thermostatic and humidity control devices and the zones they serve on plans, including perimeter system zones M1.00/ SPEC SECTION 23 0993 Where adjacent (neighboring) zones are controlled by separate thermostats (including perimeter systems used to offset heat gain or loss), and are connected by permanent openings > 10% of either zone sf area, indicate controls configured to prevent adjacent zones from operating in conflicting modes (one in heat, other in cool); applies to adjacent perimeter zones, adjacent nonperimeter zones, and adjacent perimeter and nonperimeter zones LESS THAN 10% OPENING. If applying Exception 2 to nonperimeter zones adjacent to perimeter zones, indicate that setpoints and deadband settings in these zones are coordinated so cooling in a nonperimeter zone does not occur until the temperature it that zone is 5`F higher than the adjacent perimeter zone temperature in heating NA NA C403.2.4.1.1 Heat pump supplementary heat Indicate staged heating operation with compression as the first stage of heating and supplemental heating controlled with outdoor lock -out temperature set to 40°F or less YES C403.2.4.1.2 Deadband Indicate zone thermostatic controls configured with 5°F minimum deadband for systems that control both heating and cooling SPEC SECTION - 23 0993 YES C403.2.4.1.3 Setpoint overlap restriction (thermostats) If separate heating and cooling systems with separate thermostatic control devices are used to serve a zone, indicate locations of both thermostatic control devices and the zone they serve on plans M1.00 / SPEC SECTION - 23 0993 Indicate a limit switch, mechanical stop or DDC control with programming to prevent simultaneous heating and cooling SPEC SECTION - 23 0993 YES C403.2.4.2 C403.2.4.2.1 C403.2.4.2.2 Automatic setback and shutdown Indicate zone thermostatic controls configured with required automatic setback and manual override functions, setback temperatures, and control method (automatic time clock or programmable controls); note exceptions taken M0.01 - THERMOS TAT SCHEDUL YES C403.2.4.2.3 Automatic (optimum) start Indicate system controls that adjust equipment start time required to bring each area served up to design temperature just prior to scheduled occupancy M0.01 - THERMOS TAT SCHEDUL YES C403.2.4.3 Outdoor supply air dampers Indicate automatic controls configured to close OSA damper during unoccupied equipment operation; not including economizer cooling, night flush or IMC required OSA / exhaust M0.01 - ERV SCHEDUL NO C403.2.4.3 Stairway and shaft vent dampers Indicate method of activation of stairway and shaft vent dampers (fire alarm or interruption of power) NO C403.2.4.4 Zone isolation controls For systems serving areas > 25,000 sf or spanning more than one floor, that include areas that are expected to be occupied non -simultaneously; indicate controls that allow for independent space conditioning of isolation zones; or exception taken NO C403.2.12 Heating outside a building Indicate occupancy sensing or timer switch controls configured to automatically shut off heating system when area served is unoccupied NO C403.2.4.5 Snow melt systems Indicate automatic controls configured to shut off system when pavement temperature exceeds 50°F and no precipitation is falling, and when outdoor air temperature exceeds 40°F YES C403.2.4.6 Freeze protection system controls Indicate automatic controls to shut off system when outdoor temperature exceeds 40°F, or conditions protect fluid from freezing M0.01 - VRF SCHEDUL 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 - Page 5 of 11 Mechanical Permit Plans Checklist MECH-CHK II R1 Revised January 2017 Project Title: 700 BUILDING OFFICE SPACE RENOVATION Date 2/23/2018 The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the Washington State Energy Code, Commercial Provisions. ApplicableLocation (yes,no,na) Code Section Code Provision Information Required - Must be in permit documents in Documents Building Department Notes NA C403.2.4.9 Group R1 hotel / motel guest rooms For hotels and motels with over 50 guest rooms, indicate automatic controls serving guest rooms that are capable of setback (heating) and set-up (cooling) of temperature setpoint by at least 5°F; indicate control method - activated by room entry or occupancy sensor 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 - Page 6 of 11 Mechanical Permit Plans Checklist MECH-CHK • Revised January 2017 CU Io vvasninytorr a tare cow yy ,vuc ,.vu.Nnanw , ..,,,.. ,.., ...............,....-.........y........__...0 .._ . -- -- - ------- -. _ Project Title: 700 BUILDING OFFICE SPACE RENOVATION Date 2/23/2018 The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the Washington State Energy Code, Commercial Provisions. ApplicableLocation (yes,no,na) Code Section Code Provision Information Required - Must be in permit documents in Documents Building Department Notes NA 0403.2.4.10 0403.2.4.11 Group R2 / R3 dwelling units, Group R2 sleeping units For primary space conditioning system, indicate 5-2 programmable thermostats capable of two setback periods per day; for all thermostats indicate purpose (heating only, cooling only, or both), required temperature range and at minimum a 10°F deadband; or exception taken Indicate method of ventilation air delivery (natural or mechanical) for each zone M1.00/ SPEC SECTION - 23 7219 C403.2.YES C403 2 16.4 Ventilation If mechanically delivered, indicate that systems are configured to provide not more than 150% of, but at least the minimum required volume of outdoor air to each zone per IMC, ASHRAE 62.1 or other applicable code (WAC, OSHA, etc); or exception taken M0.01 If delivered via natural ventilation, identify required elements per IMC including minimum openable area to the outdoors or qualifying adjoining spaces NA C403.2.6.2 Demand controlled ventilation Identify spaces > 500 sf with occupant load > 25 people/1,000 sf per IMC; for each space indicate whether it is served by an HVAC system with total design OSA > 3,000 cfm, and / or the system has airside economizer or automatic modulating OSA damper; indicate OSA controls are configured to provide demand controlled ventilation or provide supporting documentation for applied exception NA 0403.2.6.3 Occupancy sensors For gyms, classrooms, auditoriums and conference rooms > 500 sf, indicate occupancy -based OSA control when space is unoccupied and method (closes OSA damper or shuts -off equipment); or alternate means provided to automatically reduce OSA when space is partially occupied NA 0403.2.6.4 0403.2.6.4.1 Enclosed loading dock ventilation For enclosed loading docks, indicate ventilation / exhaust system method of activation (gas detection system for CO and NO2, or occupancy sensors), and control method (staged or modulating) NA C403.2.6.4 C403.2.6.4.2 Enclosed parking garage ventilation For enclosed parking garages, indicate ventilation / exhaust system activated by gas detection system for CO and NO2, and control method (staged or modulating); or exception taken NA C403.2.7.1 Kitchen exhaust hoods Provide calculations that show a balanced accounting of total kitchen exhaust (include all hoods) with % of: supply air, transfer air from adjacent spaces, and make-up air; if applicable, indicate that direct make-up air to each hood does not exceed 10% of hood exhaust For kitchens with total hood exhaust exceeding 2,000 cfm, indicate exhaust air rate per Table C403.2.7.1 and compliance method (DCV, energy recovery, or transfer air that would otherwise be exhausted) NA C403.2.7.2 Laboratory exhaust systems Refer to Systems Requiring Energy Recovery for requirements C403.2.13 Variable flow capacity - HVAC system fans For HVAC fan motors ? 7.5 hp, indicate method of variable flow control (VSD, or equivalent control method that reduces design air volume by 50% at 1/3 static design pressure); note exception taken NA C403.3.1 DX air handler variable cooling control For DX air handlers with economizer and cooling capacity? 65,000 Btu/h, indicate number of cooling stages provided and method (multiple compressors and / or variable speed compressors); indicate minimum displacement (capacity reduction) as % of full load (Under lntegrated Economizer) Indicate control method (cooling capacity controlled in response to space temperature, space temperature controlled by modulating supply airflow, or both) For DX air handling units with cooling capacity? 65,000 Btu/h and evaporative and chilled water air handling units with fan ? 0.25 hp, indicate whether system is single zone or multiple zone and related control method (cooling capacity controlled in response to space temperature, space temperature is controlled by modulating supply airflow, or both) NA C403.2.11.5 Fan airflow control For mechanical cooling systems (includes DX and chilled water coils) that control cooling capacity in response to space temperature - Provide a minimum of two stages of fan control; indicate minimum fan speed is 5 66% of full speed drawing 5 40% of full speed fan power during periods of low cooling or ventilation only For other mechanical cooling systems (includes DX and chilled water coils) that control space temperature by modulating airflow (in lieu of, or in addition to, controlling capacity in response to space temperature) - Provide fan controls for modulating supply airflow; indicate minimum fan speed is 5 50% of full speed drawing 5 30% of full speed fan power during periods of low cooling or ventilation only; or exception taken Provide central and zone level DDC controls as required based on system application, capacity or size thresholds and other qualification per Table C403.2.4.12.1 NA C403.2.4.12 DDC system capabilities Identify all DDC system input / output control points; indicate capability for trending and graphical display Ducting Systems YES C403.2.8.1 Duct construction Indicate on plans that all ductwork is constructed and sealed per IMC SPEC SECTION - 23 3100 C403.2.8.3 For OSA ductwork, also indicate on plans that ductwork meets air leakage requirements per C402.5 and vapor retarder requirements per the IBC NA C403.2.8.3 Duct pressure classifications Identify location of low, medium and high pressure ductwork on plans DUCTS LOW PRESSOR E' 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 - Page 7 of 11 Mechanical Permit Plans Checklist MECH-CHK 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised January 2017 Project Title: 700 BUILDING OFFICE SPACE RENOVATION Date 2/23/2018 The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the Washington State Energy Code, Commercial Provisions. Applicable (yes,no,na) Code Section Code Provision Information Required - Must be in permit documents Location in Documents Building Department Notes NA C403.2.8.3.3 High pressure duct leakage test Indicate high pressure duct leakage testing requirements on plans; provide test results to jurisdiction when completed 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 - Page 8 of 11 Mechanical Permit Plans Checklist MECH-CHK mpliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised January 2017 Project Title: 700 BUILDING OFFICE SPACE RENOVATION Date 2/23/2018 The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the Washington State Energy Code, Commercial Provisions. Applicable (yes,no,na) Code Section Code Provision Information Required - Must be in permit documents Location in Documents Building Department Notes YES C403.2.8.1 C403.2.8.2 Duct insulation For supply and return ductwork located in unconditioned space or outdoors, indicate R -value of insulation on ductwork on plans; identify climate zone; note exceptions taken NA For supply ductwork located in conditioned space, identify if design supply temperature is < 55°F or > 105°F and indicate R -value of insulation on this ductwork on plans; note exception taken NA For OSA ductwork, shafts and plenums, indicate R -value of insulation on these elements on plans per Table C402.1.3 for steel -framed walls; note exception taken SPEC SECTION - 23 0700 Piping Systems YES C403.2.9 Piping insulation p g Indicate design temperature range of fluid conveyed in piping and thickness of insulation (in inches) on hydronic piping plans; or exception taken SPEC SECTION - 23 0700 YES C403.2.9.1 Piping insulation exposed to weather Indicate method of protection of pipe insulation from damage / degradation on hydronic piping plans SPEC SECTION - 23 0700 Economizers NO C403.3 Air economizer required Identify in equipment schedules on plans or in MECH-EQ forms all cooling systems requiring air economizer controls Provide MECH-ECONO form indicating systems utilizing air economizer exceptions, including those with water -side economizer in lieu of air economizer; indicate on plans eligible exception(s) taken and measures to comply with exception(s) NO C403.3.1 Integrated economizer operation - air and water Indicate air and water -side economizers are configured for partial cooling operation even where additional mechanical cooling is required to meet the load NO C403.3.2 Economizer heating system impact - air and water Verify control method of HVAC systems with economizers does not increase building heating energy usage during normal operation NO C403.3.3.1 Air economizer capacity Indicate modulating OSA and return air dampers are configured to provide up to 100% OSA for cooling NO C403.3.1 C403.3.3.2 Integrated air economizer Verify mechanical cooling controls are interlocked with air economizer controls so the outside air damper remains in 100% open position when mechanical cooling is also required to meet the cooling load, until the leaving air temperature is < 45°F For systems with cooling capacity z 65,000 Btu/h, verify that control of economizer dampers is not based only on mixed air temperature; or exception taken NO C403.3.3.3 Air economizer high limit controls Indicate high limit shut-off control method and required high limit per Table C403.3.3.3 NO C403.3.4.1 Water economizer capacity For eligible systems where water -side economizer may be provided in lieu of air economizer, indicate system is capable of 100% design cooling capacity at 50°F db 145°F wb OSA temperatures NO C403.3.4.2 Water economizer maximum pressure drop Indicate pressure drop across precooling coils and heat exchangers in water economizer system do not exceed pressure drop limit NO C403.3.1 DX air handling equipment control For DX air handlers with economizer and cooling capacity 65,000 Btu/h, refer to HVAC System Controls for requirements NO C403.2.4.7 DX equipment economizer fault detection and diagnostics For DX air handlers with economizer and cooling capacity_ 54,000 Btu/h, provide a fault detection and diagnostics (FDD) system to monitor economizer system operation and report faults Systems Requiring Energy Recovery NA C403.5.1 Energy recovery (ER) - ventilation / exhaust systems For systems with design OSA > 5,000 cfm, or design supply air cfm and % OSA exceeding the values in Tables C403.5.1(1) or (2), indicate exhaust air ER method; or exception taken with supporting calculations For rooms served by multiple systems with aggregate design OSA > 5,000 cfm, or aggregate design supply air cfm and % OSA exceeding the values in Tables C403.5.1(1) or (2), indicate exhaust air ER method; or exception taken with supporting calculations Indicate ER rated effectiveness that increases OSA enthalpy by >_ 50% based on delta between OSA and return air enthalpies at design conditions NO C403.2.7.2 Laboratory exhaust systems (energy recovery) For buildings with total lab exhaust > 5,000 cfm, indicate method of energy recovery used to pre -condition laboratory make-up air; ER effectiveness (min 25°F); or alternative method per exception (VAV exhaust, semi -conditioned makeup, or CERM calculation) NO C404.10.4 (under C404.11) Pools and permanent spas exhaust systems (energy recovery) For buildings with pools or spas with water surface area > 200 sf, indicate exhaust air ER method and use of waste heat (preheat ventilation air, pool water or service hot water); or exception taken Indicate ER system has the rated effectiveness and is configured to decrease the exhaust air temperature at design conditions by >_ 36°F NO C403.5.2 Energy recovery - steam condensate systems For buildings with on-site steam heating systems, indicate condensate water ER For buildings that use off-site generated steam where condensate is not returned to the source, indicate on-site condensate water ER 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 - Page 9 of 11 Mechanical Permit Plans Checklist MECH-CHK nce Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised January 2017 Project Title: 700 BUILDING OFFICE SPACE RENOVATION Date 2/23/2018 The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the Washington State Energy Code, Commercial Provisions. Applicable (yes,no,na) Code Section Code Provision Information Required - Must be in permit documents Location in Documents Building Department Notes NO C403.5.3 Energy recovery - cooler / freezer condensers For buildings with food service, meat or deli departments that have > 500,000 Btu/h of remote refrigeration capacity for coolers / freezers, indicate condenser ER and use of captured energy (service water heating, space heating, or dehumidification reheating) For buildings with z 40,000 sf conditioned floor area and with z 1,000,000 Btu/h of remote refrigeration capacity for coolers / freezers, indicate condenser ER and use of captured energy for service water heating and also for space heating, or dehumidification reheating NO C403.5.4 Energy recovery - condenser systems For buildings with 24-hour operation and with > 1,500,000 Btu/h of heat rejection capacity and design service hot water load > 250,000 Btu/h, indicate condenser ER to pre -heat service water; or exception taken. Provide calculations showing the amount of recovered heat that is utilized (60% of peak heat rejection load or pre -heat service water to 85°F). Hydronic System Controls NA C403.2.13 C403.4.2.7 Variable flow control - hydronic system pumps For hydronic system pump motors >_ 7.5 hp, indicate method of variable flow control (VSD or equivalent method that requires >_ 30% design wattage at 50% design fluid flow); note exception taken Identify whether hydronic coils have DDC controls and associated manner of pump speed control (differential pressure, zone hydronic demand, etc) NA 0403.2.5 0403.4.2.4 Hydronic system setback and part load controls For boilers that provide building heating, indicate controls that provide heating water temperature setback based on outdoor temperature For heating and chilled water systems z 300,000 Btu/h, indicate systems are configured to automatically reset supply water temperature based upon demand; or exception taken. If system pump motor hp z 3 hp, also indicate controls automatically reduce flow by t 50%. For chilled water systems (2 300,000 Btu/h, pump motor hp i' 3 hp) that serve water-cooled unitary air conditioners, indicate VSD or staged pumps in chilled water system and heat rejection loop that reduce pump flow so that one control valve is nearly wide open, or to maintain a minimum differential pressure; or exception taken NA C403.4.2 Boiler sequencing Indicate automatic controls that sequence operation of multiple boilers NA C403.4.6 Hot gas bypass limitation For cooling equipment with hot gas bypass, provide either multiple step unloading or continuous capacity modulation; indicate bypass capacity per Table C403.4.6 NA 0403.4.2.2 Two -pipe changeover systems Indicate changeover deadband (min 15°F). heating / cooling mode scheduling and changeover temperature range (limit 30°F) NA 0403.4.2.6 Chiller/boiler plant pump isolation Indicate controls are configured to automatically reduce overall plant flow and shut-off flow through individual chillers and boilers when not in use NA 0403.2.13.1.1 C403.4.3.1.1 C403.4.3.1.2 Heat rejection equipment - variable flow control For cooling towers with fan motors >_ 7.5 hp, indicate VSD and method to adjust fan speed (adjusted based on leaving fluid temperature or condenser temperature / pressure of heat rejection device) For multiple -cell heat rejection equipment with VSD, indicate controls that ramp all fans in unison NA C403.4.3.3 Heat rejection equipment - cooling tower flow tumdown Indicate open -circuit cooling towers with multiple pumps or VSD control are designed so all cells can be run in parallel NA C403.4.2.3.1 Water loop heat pump - deadband Indicate capability of central equipment to provide minimum 20°F water supply temperature deadband between heat rejection and heat addition modes; or exception taken NA C403.4.2.3.2.1 Water loop heat pump - heat rejection equipment, Zone 4 Indicate type of cooling tower (open- or closed-circuit) in equipment schedule; indicate method used to limit system heat loss when heat rejection is not needed NA C403.4.2.3.2.2 Water loop heat pump - heat rejection equipment, Zone 5 For open- or closed-circuit cooling towers, provide a heat exchanger that separates the cooling tower and heat pump loop NA C403.4.2.3.3 Water loop heat pump - isolation valves For hydronic heat pump systems with total system power > 10 hp, indicate 2 -way isolation valves on each heat pump and variable flow system control Dedicated Outdoor Air Systems (DOAS) - Optional through 6/30/16, Prescriptive 7/1/2016 YES C403.6 C403.6.3 Dedicated outdoor air systems For buildings with office, retail, education, library and fire station spaces, identify these spaces on plans; indicate that ventilation air in each occupied space is provided via a DOAS system; or document compliance with C403.6.3 Impracticality; or exception taken (buildings complying with C402.4.1.4 or C406.6 may not utilize exceptions) M1.00 YES C403.6.1 Energy recovery ventilation with DOAS For all DOAS systems, indicate exhaust air ER method; or exception taken with supporting calculations. Indicate ER rated effectiveness that increases OSA enthalpy by > 50%based on delta between OSA and return air enthalpies at design conditions. M0.01 / M1.00 NO C403.6.2 Heating / cooling system controls with DOAS Indicate equipment associated with the delivery of zone level heating and cooling (fans, hydronic pumps, primary air dampers, etc) are configured to shut off, and central equipment is configured to turn down, when there is no call for heating or cooling in the zone they serve If applying Exception to heating / cooling fans used for air mixing in the space during deadband periods, include fan watts per cfm in equipment schedule 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 - Page 10 of 11 Mechanical Permit Plans Checklist MECH-CHK 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised January 2017 Project Title: 700 BUILDING OFFICE SPACE RENOVATION Date 2/23/2018 The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the Washington State Energy Code, Commercial Provisions. Applicable (yes,no,na) Code Section Code Provision Information Required - Must be in permit documents Location in Documents Building Department Notes NO C402.4.1.4 C403.6 Increased prescriptive maximum vertical fenestration area with DOAS Indicate that all occupied, conditioned spaces are served by a DOAS per C403.6 Additional Efficiency Package Option, Dedicated Outside Air Systems (DOAS) YES C406.6 Building provided with DOAS To comply with additional efficiency package option, indicate that 90% or more of all occupied, conditioned spaces are served by a DOAS per C403.6 M0.01 / M1.00 / SPEC SECTION - 23 7219 Multiple Zone Air Systems NA C403.4.4 Air systems serving multiple zones Identify supply air systems serving multiple zones and the zones they serve on plans; indicate whether system is VAV and method of primary air control; or provide supporting documentation for applied exception to VAV NA C403.4.4 VAV systems serving multiple zones Provide equipment schedules on plans or MECH-EQ form that list all VAV air terminals and types For each air terminal include: maximum airflow rates for primary supply air during zone peak heating and zone peak cooling; maximum airflow during reheating, recooling or mixing; minimum airflow rate to maintain required ventilation, and the basis for these values; if IMC or ASHRAE 62.1 multiple zone equation is basis for minimum flow rates, provide calculation on plans NA C403.4.4.1 Single duct VAV terminal units Indicate single duct terminal units are configured to reduce primary supply air before reheating or recooling NA C403.4.4.2 Dual duct systems - terminal units For systems with separate warm air and: cool air ducts, indicate terminal units are configured to reduce the flow from one duct to minimum before mixing with air from the other duct NA C403.4.1.1 C403.4.1.2 VAV system static pressure sensors - sensors and DDC set points Indicate locations of duct static pressure sensors on plans; include at least one sensor per major duct branch; verify controller setpoint pressure at each sensor is 5 1.2 inch w.g. For systems with zone level DDC, indicate controls are configured to monitor zone camper positions and reset staticpressure setpoint based on the zone requiring most pressure; include P q 9 control logic that automatically detects and generates an alarm if any zone excessively drives reset logic, and allows building operators to exclude zones from reset logic NA C403.4.4.3 Multiple -zone VAV system ventilation optimization controls For systems with zone level DDC controls, indicate controls are configured to automatically reduce outdoor airflow in response to changes in system ventilation efficiency; or exception taken NA C403.4.4.4 VAV system supply air reset Indicate controls automatically reset supply air temperature in response to building loads or outdoor air temperature; or exception taken Multiple Zone HVAC Systems, High Efficiency VAV - Required for systems utilizing C403.6 DOAS Exception 2, must comply with all 16 provisions NA C403.7, Item 1 Air economizer Indicate system is configured for 100% air economizer operation and complies with ail related economizer requirements per C403.3 (without economizer exceptions) NA C403.7, Item 2 Direct digital controls (DDC) Provide DDC controls for all components of system; identify all DDC system input / output control points; indicate capability for trending and graphical display NA C403.7, Item 3 Outdoor airflow measurement and reduction For systems with minimum OSA > 2,500 cfm, indicate outdoor airflow monitoring station that measures OSA intake under all load conditions; indicate control sequence that increases or reduces system OSA cfm based on VAV terminal feedback of ventilation efficiency (per C403.4.4.3 without exceptions) or DCV (per 0403.2.6.2) NA C403.7, Item 4 Supply airflow measurement For systems with minimum OSA > 2,500 cfm, indicate supply airflow monitoring station capable of measuring supply air delivered to VAV terminals under all load conditions NA C403.7, Item 5 Zone isolation and maximum area served Verify maximum area served by a single HEVAV system is <_ 50,000 sf, or one entire floor, whichever is greater; in addition if a system serves > 25,000 sf, that includes areas that are expected to be occupied non -simultaneously, indicate zone isolation controls per C403.2.4.4 NA C403.7, Item 6 Interior / exterior zone design supply air temperature Verify that VAV terminals serving interior cooling driven loads are sized per design sapply air temperature that is 5°F higher than VAV terminals serving exterior zones NA C403.7, Item 7 Maximum air terminal inlet velocity Identify air terminals with minimum primary airflow setpoints > 50% of maximum setpoint in equipment schedule or MECH-EQ form; indicate air terminal inlet velocity does not exceed 900 fpm NA C403.7, Item 8 Sequence of operation Indicate DDC system sequences of operation are designed and configured per ASHRAE GPC 36 NA C403.7, Item 9 Maximum allowable system brake horsepower Verify fan system bhp is <_ 90% of the bhp limit per Option 2 equation in Table C403.2.11.1(1), provide MECH-FANSYS form for each system NA C403.7, Item 10 Fan -powered terminal unit motor and control Indicate all series and parallel terminal fans have electronically commutated motors; indicate DDC control system is configured to vary air terminal fan speed as a function of the load; indicate fan speed during periods of low heating, low cooling, or ventilation only is<_ 66% of peak design air flow or provide supporting documentation for applied exception 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 - Page 11 of 11 Mechanical Permit Plans Checklist MECH-CHK mpliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised January 2017 Project Title: 700 BUILDING OFFICE SPACE RENOVATION Date 2/23/2018 The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the Washington State Energy Code, Commercial Provisions. Applicable (yes,no,na) Code Section Code Provision Information Required - Must be in permit documents Location in Documents Building Department Notes NA . C403.7, Item 11 Application of single duct and fan -powered terminal units Indicate VAV terminal types on plans; verify fan -powered terminal units only serve perimeter zones with envelope loads; verify all other zones are served by single duct terminal units NA C403.7, Item 12 Fan -powered terminal unit primary air reset Indicate DDC controls are configured to automatically reset the primary supply air cfm setpoint of all fan -powered terminal units to the minimum required to maintain ventilation during occupied heating or deadband, based upon the VAV air handling unit OSA ventilation fraction NA C403.7, Item 13 High occupancy space controls For spaces > 150 sf with occupant density Z 25 people / 1000 sf, indicate space is served by a dedicated terminal unit with DCV control that resets terminal unit ventilation setpoint; also indicate occupancy sensor control that automatically reduces minimum ventilation to zero and sets back room heating and cooling setpoints by > 5°F NA C403.7, Item 14 Dedicated HVAC systems For server, electronic equipment, telecom or similar spaces with cooling loads > 5 W/sf, indicate spaces are served by independent HVAC systems that are separate from HPVAV systems serving rest of building; indicate dedicated HVAC systems have air economizer controls or energy recovery per C403.3 Exception 9 NA C403.7, Item 15 Central plant efficiency Indicate whether systems are served by a high efficiency heating water plant, or a high efficiency chilled water plant If complying via high efficiency heating water plant: Indicate all VAV terminals have hydronic heating coils served by heating water system with either gas-fired boiler(s) with thermal efficiency >_ 90%, air -to -water heat pumps, or heat recovery chillers If complying via high efficiency chilled water plant: Indicate all VAV air handlers have cooling coils served by chillers with rated IPLV efficiency that exceeds WSEC listed IPLV by at least 25% per Table C403.2.3(7) (note water-cooled IPLV is max, all others are min); indicate smallest chiller or compressor in plant is 5 20% of total plant capacity, or provide thermal storage sized for 5 20% of total plant capacity NA C403.7, Item 16 Fault detection and diagnostics Indicate DDC system includes a fault detection and diagnostics (FDD) system configured to monitor operation and provide fault reporting of required parameters for all VAV air handlers and VAV air terminal units in the HPVAV system HVAC Equipment Energy Use Metering NA C409.3.1 HVAC equipment energy use metering For new buildings > 50,000 sf and building additions > 25,000 sf, verify energy use metering of all equipment used to provide space heating and cooling, dehumidification and ventilation will be provided per C409; indicate equipment eligible for exception Documentation and System Specific Requirement To Support Commissioning YES C408.2 Scope of mechanical systems commissioning Indicate that all mechanical systems, equipment, and controls for which the WSEC requires control functions and / or configuration to perform specific functions are required to be commissioned; M0.01 For buildings with >_ 240,000 Btu/h total output cooling capacity or >_ 300,000 Btu/h total output heating capacity, indicate that all mechanical systems regardless of individual capacity are required to be commissioned; or provide building heating / cooling capacity calculation demonstrating eligibility for exception NA YES C403.2.10 C408.1.1 C408.1.2 C408.1.4.2 C103.6 Commissioning requirements in construction documents Indicate in plans and specifications that Cx per C408 is required for all applicable mechanical systems; M0.01 Include general summary with at a minimum of Items 1 thru 4 of the Cx plan per C408.1.2 including: narrative description of activities, responsibilities of the Cx team, schedule of activities including verification of project close out documentation per C103.6, and conflict of interest plan (if required); M0.01 Include in general summary that a Cx project report or Compliance Checklist (Figure C408.1.4.2) shall be completed by the Certified Cx Professional and provided to the owner prior to the final mechanical inspection. M0.01 NA C408.2.2 Air system and hydronic system balancing Indicate in plans that air and fluid flow rates shall be tested and balanced within the tolerances defined in the specifications; indicate systems shall be balanced in a manner to first minimize throttling losses, then adjusted to meet design flow conditions YES C408.2.2.1 Air system balancing devices Indicate devices that provide the capability to balance all supply air outlets, zone terminals and air handling equipment requiring system balancing M0.01 NA C408.2.2.2 Hydronic system balancing devices Indicate devices that provide the capability to isolate, balance and measure flow across all hydronic equipment requiring system balancing including heating and cooling coils and pumps YES C408.2.3 Functional performance testing criteria Identify in plans and specifications the intended operation of all equipment and controls during all modes of operation, including interfacing between new and existing -to -remain systems M0.01 Project Close Out Documentation YES C103.6 Documentation and project close out submittal requirements Indicate in plans that project close out documentation and training of building operations personnel is required for all mechanical components, equipment and systems governed by this code; indicate close out documentation shall include: record documents, O&M manuals, applicable WSEC compliance forms and calculations M0.01 Att I�_ ODll NE UD ORFER ENGINEERS INC. TEST, ADJUST & BALANCE BALANCE REPORT 700 Building Office Space Renovation 700 Andover Park West Tukwila, Washington 2019-095 Project Completion Date: 01/24/19 Revision Date: Revision Number. WILLIAM C. NEUJDORFER CERTIFICATION 2465 Exp.3/31/19 5516 1't Ave S Seattle, WA 98108 Phone (206) 621-1810 Fax (206) 343-9820 2501 SE Columbia Way, Ste. #230 Vancouver, WA 98661 Phone (503) 235-8924 Fax (503) 235-8925 Neudorfer Engineers. Inc. Consulting Engineers Seattle Portland PROJECT LOCATION 700 Building Office Space Renovation Tukwila, WA Cover Report Title Certification Warranty Terms of Abbreviations Executive Summary Energy Recovery Unit TAB Drawings Instrument Calibration TABLE OF CONTENTS 2 4 5 6-7 8 9-10 11-14 15 Neudorfer Engineers. Inc. Consulting Engineers Seattle Portland Report Title CERTIFIED TEST: BALANCE REPORT Project: 700 Building Office Space Renovation 700 Andover Park West Tukwila, Washington NEI Job#: 2019-095 Engineer: -- Contractor: Capital Heating and Cooling TAB Firm: Neudorfer Engineers Inc 5516 1st Avenue South Seattle, WA 98108 Test Engineer: Xuan Nguyen Architect: -- 5516 1" Ave S Seattle, WA 98108 Phone (206) 621-1810 Fax (206) 343-9820 3 2501 SE Columbia Way, Ste. #230 Vancouver, WA 98661 Phone (503) 235-8924 Fax (503) 235-8925 Neudorfer Engineers. Inc. Consulting Engineers Seattle Portland www NoudorterEnpin Dom CERTIFICATION The data presented in this report is a record of system measurements and final adjustments that have been obtained in accordance with the current edition of the NEBB Procedural Standards for Testing, Adjusting, and Balancing of Environmental Systems. Any variances from design quantities which exceed NEBB tolerances are noted in the Test-Adiust-Balance Report Proiect Summary. Significant / Noteworthy Remarks are noted on the General Remarks and General Field Notes pages. Other remarks are noted on individual test sheets. Noted deficiencies are not Neudorfer Engineers responsibility to repair. Prior to issuance of this report, Deficiency Reports are forwarded to our contracted agent. Warranty is limited to one year from date of this report. Within that time, any discrepancies, ambiguities, or omissions found in this report will be retested, adjusted, or balanced as needed. A written notification will be required. Submitted and Certified by: NEBB TAB Firm: Neudorfer Engineers Inc Certification No: 2465 Expiration Date: March 31, 2019 Certification Date: January 24, 2019 (Date completed) Signed and Sealed by: NEBB Supervsor: William C. Neudorfer 4 Neudorfer Engineers. Inc. Consulting Enginoors Seattle Portland Warranty Project: 700 Building Office Space Renovation Warranty of Services: Neudorfer Engineers, Inc. warrants that the air balancing, evaluated during this performance evaluation are operating at the specified levels as documented within this report. At and only this time, and makes no other warranties, stated or implied, concerning the continued performance, operation or safety in the use of this equipment past this time. Neudorfer Engineers warrants the air and hydronic balancing for 1 year from the date of substantial completion. Neudorfer Engineers reserves the right to correct errors or omissions in the collections of data. Warranty Procedures: For all warranty items, Neudorfer Engineers requires written request. The written request should be specific on the areas of concern, such rooms, or equipment, and the type of issue the occupants are experiencing. Once written notification is received, Neudorfer Engineers will schedule a Technician. It is recommended that an Owner or A/E Representative be on site at that time. Voided Warranty and Additional Charges: If a complaint issue is due to a mechanical equipment failure, control or maintenance related, the return trip maybe subject to a service charge, not covered under warranty. Neudorfer Engineers reserves the right to resolve any TAB issue. If a third party or competing Test & Balance Commissioning firm test or adjust any equipment, all project warranty is voiided. (This is typical standard for the Mechanical industry, as Manufacture, Mechanical and Control Contractor voids all warranty when a competing firm tests or manipulates their systems.) Any return trips to the job site are subject to a service charge and a purchase order will be required before returning to the job site. Document Archiving An electronic file of all test documents will be kept on file until the end of the Warranty period. During that time and electronic copy of the test data will be provided a no charge. Any additional hard / bound copies requested will be subject to a fee. 5 Neudorfer Engineers. Inc. Consulting Engineers Seattle Portland Terms and Abbreviations Project: 700 Building Office Space Renovation AC or ACU Air Conditioner or Air Conditioning Unit Act. Actual ACCU Air Cooled Condensing Unit Address Equipment designation number given on the Control Program AH or AHU Air Handler or Air Handling Unit Amps Amperage AP Access Point APP. Application Arr Arrangement AVG Average BHP Brake Horsepower BTU British Thermal Units BTUH British Thermal Units per Hour CAV Constant Air Volume CBV Calbirated Balancing Valve (Circuit Setter) CC Cooling Coil CD Ceiling Diffuser CFLA Correct Full Load Amperage CFM Cubic Feet per Minute CH Chiller CHWS Chilled Water Supply CHWR Chilled Water Return Coeff. Coefficient CP Circulating Pump CR Ceiling Register CRAC Computer Room Air Conditioner CRU Computer Room Unit CT Cooling Tower CU Condenser Unit CUH Cabinet Unit Heater CWS Condenser Water Supply CWR Condenser Water Return DAT Discharge Air Temperature DB Dry Bulb DD Direct Drive DDC Direct Digital Controls: EMS Control System for the HVAC Delta Difference, net decrease or increase 6 Des. Design Dia. Diameter Disch. Discharge DNL Data Not Listed EA Exhaust Air EAT Entering Air Temperature Economizer Controls and components that allow an air handler to logically utilize outdoor air for cooling as opposed to the use of mechanical cooling. EDC Electric Duct Coil EDH Electric Duct Heater EF Exhaust Fan EG Exhaust Grille EMCS Energy Management Control System ERU Energy Recovery Unit E.S.P. Extemal Static Pressure Evap. Evaporator EWT Entering Water Temperature FCU Fan Coil Unit FD Fire Damper FH Fume Hood FLA Full Load Amperage: Maximum amperage a motor can draw. Flow Hood Instrument that captures air and converts the reading to CFM. FPB Fan Powered Box FPM Feet per Minute FR Field Report FT Foot, Feet FTU Fan Terminal Unit GPM Gallons per Minute HC Heating Coil HD Pressure Difference across the entering and leaving side of a pump. Heater O.L. Thermal overload protection for motors located at the motor starter (starter heaters) HEPA High Efficiency Particulate Arrestance HOA Hand / Off / Auto Switch HP Horsepower Neudarfer Engineers. Inc. Consulting Engineers Seattle Portland Terms and Abbreviations Project: 700 Building Office Space Renovation HRC Heat Recovery Coil HUH Hydronic Unit Heater HVAC Heating Ventilation and Air Conditioning HWS Heating Water Supply HWR Heating Water Return HX Heat Exchanger HZ Hertz, cycle per second I.D. Inside Diameter in. inches in.w.g. inches of water gauge Kfactor Correction factor to the free area need to calculate CFM. KW Kilowatts LAT Leaving Air Temperature LWG Low Wall Grille LWR Low Wall Register LWT Leaving Water Temperature MAU Make-up Air Hangling Unit MBH 1,000 BTUH MAX. Maximum Flow Requirements for DDC MBH Mega BTUs per hour (1MBH=1,000BTUH) MIN Minimum Flow Requirements for DDC N/A Not Available N/S Not Shown or Specified OA Outside Air OBD Opposed Blade Damper O.D. Outside Diameter PD Pressure Drop. PH Phase PHC Preheat Coil Prim. Primary PSI Pounds per Square Inch RA Retum Air RAT Retum Air Temperature RF Return Fan RH Relative Humidity RHC Reheat Coil RPM Revolutions per Minute RTU Roof Top Unit 7 RVA Rotating Vane Anemometer -reads air velocity in feet per minute SA Supply Air SAT Supply Air Temperature S.F. Service Factor Schedule Design data obtained from the (sched) mechanical prints' schedule of equipment. SCR Silcon Controlled Rectifier Speed Controller Supply Fan Smoke/Fire Damper Static Pressure Specifications square feet Submitted data on equipment capabilities. Suction Sidewall Grille Sidewall Register Test; Adjust; and Balance Tachometer Technician Total Static Pressure: Difference between the entering and leaving static pressure of a fan. Traverse or Test Point Unit Heater Variable Air Volume; box that contains a motorized damper that modulates airflow. Volume Damper Variable Frequency Drive Instrument that reads used to read velocity in feet per minute. Velocity Pressure Variable Volume Terminal Water Column Water Gauge Wet Bulb SF SFD SP Spec(s) sq.ft. Submittals (subs) Suct. SWG SWR TAB Tach Tech TSP TP UH VAV VD VFD Velgrid VP WT WC W.G. WB Neudorfer Engineers. Inc. CenseIting Engineers Seattle Portland PROJECT 700 Building Office Space Renovation LOCATION Tukwila, WA NEI # 2019-095 EXECUTIVE SUMMARY This project has been balanced per plans and specifications using the National Environmental Balancing Bureau (NEBB) standards and procedures. The scope of this project is to balance seven supply grilles and three exhaust grilles that are served by the ERV -01. The unit has been checked for total airflow, unit data, operating amperage, voltage, rotation, operating static pressure. All outlets and inlets have been proportioned to design specifications of unless otherwise noted. Balancing diagrams are attached to this report with outlets numbered for locations. ENERGY RECOVE:RY VENTILATOR ERV -01 Supply Fan is a constant volume direct drive fan that serves Weatherization 211, Conference 203, Open Office 200, Office 204, Office 205, and Office 206. .The supply fan is delivering 467 CFM of 470 CFM (99%) of design. ERV -01 Exhaust Fan is a constant volume direct drive fan that serves Conference 203, Open Office 200, and Copy Room 207. The exhaust fan is delivering 425 CFM of 470 CFM (90%) of design. NATIONAL ENVIRONMENTAL BALANCING BUREAU 8 Neudorfer Engineers. Inc. Consulting Engineers Seattle Portland Energy Recovery Unit PROJECT: 700 Building Office Space Renovation LOCATION: Tukwila, PROJECT #: 2019-095 DATE: 1/24/2019 CONTACT: Xuan Nguyen AUTHOR: SYSTEM/UNIT: ERV -1 Unit Data Unit Manufacturer Mitsubishi Unit Model Number LGH-F470RX5-E1 Unit Serial Number 00001405 ERV-1/Lossnay Core Filter Type Filter Quantity - Size 1 Filter Dimensions - Size 1 Heat Exchanger Core 2 10.5"x10.5"x17.25" Test Data SF Total Design Flow SF Total Actual Flow EF Total Design Flow EF Total Actual Flow ERV-1/Exhaust Fan Motor Volts T1-T2 Motor Amps T1 ERV-1/Sunniv Fan Motor Volts T1-T2 Motor Amps T1 470 CFM 467 CFM 470 CFM 425 CFM 209 Volts 1.0 Amps 209 Volts 1.0 Amps Log: Tested By: Xuan Nguyen Date: 1/24/2019 Motor Data ERV-1/Exhaust Fan Drive Type Direct Drive Motor HP 0.23 HP Motor Rated Volts 208-230 Volts Motor Phase 1 Motor Hertz 60 Hz Motor FL Amps 1.4 Amps ERV-1/Suooly Fan Drive Type Motor HP Motor Rated Volts Motor Phase Motor Hertz Motor FL Amps Direct Drive 0.23 HP 208-230 Volts 1 60 Hz 1.4 Amps Test Pressures SF Actual TSP SF Actual ESP SF Pre -Filter SP In SF Fan SP In SF Fan SP Out SF HEX SP Out EF Pre -Filter SP In EF Fan SP In EF Fan SP Out EF HEX SP Out 0.75 in. w.c. 0.32 in. w.c. -0.23 in. wc -0.61 in. wc 0.14 in. wc -0.61 in. wc -0.41 in. wc -0.69 in. wc Not Accessible in. wc -0.69 in. wc ERV -1 ERV -1 ERV -1 1/23/2019 Xuan Nguyen 1/23/2019 Xuan Nguyen 1/24/2019 Xuan Nguyen (1) The volume damper is full open. (2) The volume damper is full dosed. (3) The outlet has been deleted per the general contractor. ERV -1 Supply Outlet Summary System/Unit Area Served Type of Reading Outlet Type Size LxW / D AK Design Velocity Design Value Prelim Reading Final Reading Final % Remarks Outlet -01, 02, and 03 Weatherization 211 Airfoil Duct 6"X6" 0.196 - 95 85 95 100 (2) Outlet -04 Conference 203 Flowhood S1 6"X6" 1.0 - 115 105 110 96 (1),(3) Outlet -05 Open Office 200 Flowhood S1 6"X6" 1.0 - 100 110 100 100 Outlet -06 Open Office 200 Flowhood S1 6"X6" 1.0 - 100 105 95 95 Outlet -07 Office 204 Flowhood S1 6"X6" 1.0 - 20 28 24 120 (2) Outlet -08 Office 205 Flowhood S1 6"X6" 1.0 - 20 25 22 110 (2) Outlet -09 Office 206 Flowhood S1 6"X6" 1.0 - 20 23 21 105 (2) Totals: - - - - - 470 481 467 99 - Neudorfer Engineers, Inc. 9 Page 1 of 2 Neudtrfer Engineers: Inc. Consulting Enginoors Soattie Rariland wtirw. NeudorterEngln a ...com Energy Recovery Unit PROJECT: 700 Building Office Space Renovation LOCATION: Tukwila, PROJECT #: 2019-095 ERV -1 Exhaust Inlet Summary DATE: 1/24/2019 CONTACT: Xuan Nguyen AUTHOR: System/Unit Area Served Type of Reading Outlet Type Size LxW / D AK Design Velocity Design Value Prelim Reading Final Reading Final % Remarks Inlet -01 Open Office 200 Flowhood EG 24"x24" 1.0 - 240 155 215 90 Inlet -02 Conference 203 Flowhood EG 24"x24" 1.0 - 115 90 105 91 Inlet -03 Copy Room 207 Flowhood EG 24"x24" 1.0 - 115 195 105 91 Totals: - - - - - 470 440 425 90 - Neudorfer Engineers, Inc. Page 2 of 2 10 33.44R32g;f+813228 "gAgggail. 9 E,428P8988 g wrwmx:^F 3$79 ae9/Ep4M1 pip E12S9ai1i83 1/i1p9Wt, Ai91 22 3E* 3/333 'e°F ���E-5 3333331 RSiRi i i3i.ii:3+1dA'.i£i.d 7 Py 4 E111Milf T- EE 11111 RPPPE 91 flil11 ee f � 4d > F9'F 3;t3¢ Ekfffi ir1 11111114' 9111 3 mala§C �92 01 t • 9>'n El 15156E4E!l1* 's5-5^5"a`5t4FFE fF "1g ,gfF ;123 F+a ^ AF 3 Aa A359ibtihi •L {E29[49 p991g9"l: iia a04 j#4. P19y T PSg€1,t 33 BI12 i 8a 3 3siik e 11 1E1 9 d@@111S18 sidae,ycad t R 11141 5 3 aeF gea@ Iaa3eE� daa of Iniaac cS iliPi9doe§3113 348 P41141 : 1881 .F 28848888 39dg0 41010p0 2ik iib 43 E "'-pdddd'eiy:i �3i'dAAia' ,h 54411411i"';"'": ;apo -144t,• OA to -101411M00 I ,p�1 AtAEACd yS jp, pp"! 18"fg 1M18888 AEdEf�(5�°E 'Ilip 535 9 10 iPa_p a`01i13 0111111111111iP ,roo ;E 1 - pin f! 13 1283883 3822 .F i3i{3d$4§ k 353M 17 44'84 i 9 444''3i 6aate -E Efig`a6 11 1 4512 ii -a�s h £gNIT , i�ii ii c; a 3Ii 88aipliOis 4,a� 3 I °ae`- a : 9 is DRAWING INDEX g 8 21 8 x@2.iiaEiii' 1j 1J114 -AApAAARRppppFR f FLo ii1i3 HS R O C3 KING COUNTY HOUSING AUTHORITY 700 BUILDING OFFICE SPACE RENOVATION 700 ADOVER PARK WEST TUKWILA, WA 98188 CD cD CO C 7Jr 0 00 Z m VI T 0 m c 0 z n 0 c 0 c co Z G) R I 98 I NOIS30 IO SISV8 $5' R° 3 Fi gL tl 3 : iz $ Eg F f .i„ Q$ i�E� `T € f S]] ��" $ ,F "o E i 0tg Y 'c'• i" R g$�"' § �• 5 °R y iiR R it C I •i $ A$g:y eCi ao �¢ i , P E a `:F � p 4 :4;E R 3 2n i i, S g3[ -• 4si " E3 g$ 3` 3E3 53 a E 3. i '� ,� f a q Pm 2 4 Y R Y • m f= R3 v '�<r f a-Y,L A"34," m ➢� 1" YpA 3' 4 0� o; yg,� 94 Z �E �f � A 3•i i9 r! � a ��°�Y� Sg ��� 4� Yf4 4 i"� Y � 9R :1 sye a2 =Gg°� C Y`^ f s yy4� m' �E ggag () m "4 cgr SLR 2: g'�47gLi p Ro 24. 403 4 4.� Y{' . Wm Ri � a€ o€�p m� Y $Q;A2` �3e '6�' fR R4fRc �8 z $ 2R:` 41€ m F '�• a€� f4 `Y YgE83p} �4 z 'z $ 6$a Eg 4=g a e$§ m F34 EF S� 8� S s 43 � � m I 3" 9 9 m p _ SR���'f�� �.R.� ��Q'�g �'4€9 �'9 ���^`p���r4Y gg ygg "e"g ` 2Y -pp'. 7e° 4.1'9 g3' q• 9f°5im 9'i' S6 gb9ai£ @g 1�, 7� t934Y `i�:a9p�yp' � �p���!! c"p77 egY 8 4zF It:;A MMa" iQ` RY•:� i gp$g€ °.;:° f34E,g4o `yFa^4$.ypoY4i s pg,m�$ 3EE,�� ania`' EzESypp• C 9Fggg 7 3[�n$ Cmq f Y� gE 3 4 $�4€i g $� n" f i eY$ 3 2 3gR 9' e MECHANICAL SYSTEMS COMMISSIONING NOTES a 8 [ III 11 rig 111 1 t1 !; I.lit IF 11 [1 i 13 91 ,'j1[ 1110-1. 41%1':3 1' ,16 , Til 912:1 11313 F ,i Il 11313 [ AI 1111 gavel 3333' ata..fa[cavrl. 3133. a2281A3i33i JO. SG11 .JJJ. IIII JJJJiIIJII 122111 1 111111101 M E1 21111111 I�II:Ik11 1111[111111 11 999[ 5 .111 1� 1 3 S31VS NOI1VI11N3A } 0 t 9 KING COUNTY HOUSING AUTHORITY 700 BUILDING OFFICE SPACE RENOVATION 700 ADOVER PARK WEST TUKWILA, WA 98188 5e ER Bi E$ 22 ao 8®® V (�) om l! gttD00� 4 3 ON3031 1V3INVH3311 g x3411= 0i3a31:ztit200p3 •4g3311i33"ggigg;5 ': $ 4° e f lsssc9� 9TQs1 I" SNOILVIA3N88V 1V3INVH334,1 '10 $z !3 m Z m O m n 0 m m Zi a t 1 2 A S21311O211NOO DEI .rg$ R_9 Ali 4E YF { 6 30 O C7 0 O D c c v 2! RI 3a 95 22 3{ $ ap Ry .a 9139 fi E. 5 { 1 1 E. 3 { { 3 0" i 98 { Z 0 0 701 2 m m c N 9 8 KING COUNTY HOUSING AUTHORITY 700 BUILDING OFFICE SPACE RENOVATION 700 ADOVER PARK WEST TUKWILA, WA 98188 SaLON 1V1:13N30 0 cn m m —1 z 0 cn • Neudorfer Engineers. Inc. Consulting Engineers Seattle Portland Instrument Calibrations Instrument Type Air Data Meter with Flowhood Instrument Manufacturer Shortridge Instrument Model Number ADM 870 Instrument Serial # M10882 Calibration Due Date 1/26/2019 Instrument Type Tachometer Instrument Manufacturer Shimpo Instrument Model Number DT -205L Instrument Serial # C08B0559 Calibration Due Date 8/21/2019 Instrument Type Amp Probe Instrument Manufacturer Fluke Instrument Model Number 324 Instrument Serial # 35670304WS Calibration Due Date 8/21/2019 Instrument Type Temperature Probe Instrument Manufacturer Shortridge Instrument Model Number ADM 870 Instrument Serial # M10882 Calibration Due Date 1/26/2019 Instrument Type Air Foil Instrument Manufacturer Shortridge Instrument Model Number ADM 870 Instrument Serial # M10882 Calibration Due Date 1/26/2019 Instrument Type Hydrometer Instrument Manufacturer Shortridge Instrument Model Number HDM-250 Instrument Serial # W11007 Calibration Due Date 1/5/2019 15 October 04, 2018 City of Tukwila Department of Community Development HEATH MAC COY 700 ANDOVER PARK W TUKWILA, WA 98188 RE: Correction Letter # 1 to Revision #1 MECHANICAL Permit Application Number M18-0037 KING COUNTY HOUSING AUTHORITY - 700 ANDOVER PARK W Dear HEATH MAC COY, Allan Ekberg, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments. • (GENERAL INFORMATION NOTE) PLAN SUBMITTALS: (Min. size 11 x17 to a preferably maximum size of 24x36; all sheets shall be the same size; larger sizes may be negotiable. "New revised" plan sheets shall be the same size sheets as those previously submitted.) "STAMP AND SIGNATURES" (If applicable) For Engineers: "Every page of a plan set must contain the seal/stamp, signature of the licensee(s) who prepared or who had direct supervision over the preparation of the work, and date of signature. Specifications that are prepared by or under the direct supervision of a licensee shall contain the seal/stamp, signature of the licensee and the date of signature. If the "specifications" prepared by a licensee are a portion of a bound specification document that contains specifications other than that of an engineering or land surveying nature, the licensee need only seal/stamp that portion or portions of the documents for which the licensee is responsible." It shall not be required to have each page of "specifications" (calculations) to be stamped and signed; Front page only will be sufficient (WAC 196-23-010 & 196-23-020). Architects: "date" only not required (WAC 308-12-081). (BUILDING REVIEW NOTES) 1. Plans provided have an engineer's stamp with no signature and date. Provide plans with the engineer's signature on the stamp with the Date of signature. See General Note above. Note: Contingent on response to these corrections, further plan review may request for additional corrections. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 Sincerely, Bill Rambo Permit Technician File No. M18-0037 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 City of Tukwila Department of Community Development 8/1/2018 HEATH MAC COY 700 ANDOVER PARK W TUKWILA, WA 98188 RE: Permit Application No. M18-0037 KING COUNTY HOUSING AUTHORITY 700 ANDOVER PARK W Dear HEATH MAC COY, Allan Ekberg, Mayor Jack Pace, Director In reviewing our current application files, it appears that your permit applied for on 3/16/2018, has not been issued by the City of Tukwila Permit Center. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or National Electrical Code every permit application not issued within 180 days from the date of application shall expire and become null and void. Currently your application has a status of APPROVED and is due to expire on 9/16/2018. If you still plan to pursue your project, you are hereby advised to do one of the following: 1) If the plan review is complete for the project and your application is approved, you may pick up the application before the date of expiration. At the time of permit issuance the expiration date will automatically be extended 180 days. -or- 2) If the plan review is not completed submit a written request for application extension (7) seven days in advance of the expiration date. Address your extension request to the Building Official and state your reason(s) for the need to extend your application. The Building Code does allow the Building Official to approve one extension of up to 90 days. If it is determined that your extension request is granted, you will be notified by mail. In the event that we do not receive your written request for extension or request is denied, your permit application will expire and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, UVAr9 Riichelle Rip ey Permit Technician File No: M 18-0037 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 March 21, 2018 City of Tukwila Department of Community Development HEATH MAC COY 700 ANDOVER PARK W TUKWILA, WA 98188 RE: Correction Letter # 1 MECHANICAL Permit Application Number M18-0037 KING COUNTY HOUSING AUTHORITY - 700 ANDOVER PARK W Dear HEATH MAC COY, Allan Ekberg, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING - M DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments. • (GENERAL INFORMATION NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of24x36; all sheets shall be the same size. "New revised" plan sheets shall be the same size sheets as those previously submitted.) "STAMP AND SIGNATURES" (If applicable) For Engineers: "Every page of a plan set must contain the seal/stamp, signature of the licensee(s) who prepared or who had direct supervision over the preparation of the work, and date of signature. Specifications that are prepared by or under the direct supervision of a licensee shall contain the seal/stamp, signature of the licensee and the date of signature. If the "specifications" prepared by a licensee are a portion of a bound specification document that contains specifications other than that of an engineering or land surveying nature, the licensee need only seal/stamp that portion or portions of the documents for which the licensee is responsible." It shall not be required to have each page of "specifications" (calculations) to be stamped and signed; Front page only will be sufficient (WAC 196-23-010 & 196-23-020). Architects: "date" only not required (WAC 308-12-081). (BUILDING REVIEW NOTES) 1. Plan sheets are missing the date of the engineer's signature. Please provide plan sheets with engineer's signature and date of the signature. See General note above. Note: Contingent on response to these corrections, further plan review may request for additional corrections. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 Sincerely, ----?cytCV Bill Rambo Permit Technician File No. M18-0037 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 / PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M18-0037 DATE: 10/30/18 PROJECT NAME: KING COUNTY HOUSING AUTHORITY SITE ADDRESS: 700 ANDOVER PARK W Original Plan Submittal Revision # before Permit Issued X Response to Correction Letter # 1 X Revision # 1 after Permit Issued DEPARTMENTS: Pct fr VIII Building Division Public Works ❑ Fire Prevention Structural n Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 11/01/18 Structural Review Required REVIEWER'S INITIALS: DATE: n APPROVALS OR CORRECTIONS: Approved Corrections Required n Approved with Conditions ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) DUE DATE: 11/29/18 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 L�EPMIT COORD COPY 0 PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M18-0037 DATE: x/26/18 PROJECT NAME: KING COUNTY HOUSING AUTHORITY SITE ADDRESS: 700 ANDOVER PARK W Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # X Revision # 1 after Permit Issued DEPARTMENTS: � Csrr(Z. 61—)--10 Building Division Public Works A -M A/i4 q�7�r8 Fire Prevention1.4 Structural Planning Division n nPermit Coordinator n PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 09/27/18 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved DUE DATE: 10/25/18 ❑ Approved with Conditions n Corrections Required Denied (corrections entered in Reviews (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: W 1 1bit/ Departments issued corrections: Bldg► i Fire ❑ Ping 0 PW 0 Staff Initials: 12/18/2013 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M18-0037 DATE: 04/06/18 PROJECT NAME: KING COUNTY HOUSING AUTHORITY SITE ADDRESS: 700 ANDOVER PARK W Original Plan Submittal Revision # before Permit Issued X Response to Correction Letter # 1 Revision # after Permit Issued DEPARTMENTS: Building Division Public Works di Fire Prevention Structural Planning Division ❑ Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 04/10/18 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: Approved ❑ Approved with Conditions gr Corrections Required ❑ Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: 05/08/18 REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: 12/18/2013 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M18-0037 DATE: 03/16/18 PROJECT NAME: KING COUNTY HOUSING AUTHORITY SITE ADDRESS: 700 ANDOVER PARK W X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: ,1..5 Cor f 1° -2-14 6 Building Division Public Works ❑ A -i' A/4 - 8 Fire Prevention 111 Structural Planning Division ❑ Permit Coordinator El PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 03/20/18 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 04/17/18 Approved ❑ Approved with Conditions ❑ Corrections Required Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: —.)—I Departments issued corrections: Bldg Fire 0 Ping 0 PW 0 Staff Initials: 12/18/2013 PROJECT NAME: R.1 5t14 SITE ADDRESS: „1 Ni 0 eir PERMIT NO: MI% / OD ORIGINAL ISSUE DATE: C6112)114 REVISION LOG REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF I T ALS 1 £Lt Summary of Revision: 15\t On CUAA ut, h?e,0 al ofh Received by: Received by:N.\/\-ks--k.04 G-LCA-C12kik REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) / City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 10 1301 Plan Check/Permit Number: M i —003-7 ❑ Response to Incomplete Letter # Response to Correction Letter # Di Revision # ` after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner ❑ Deferred Submittal # Project Name: [SCA Project Addressrt Contact Person: C�..LAid- CoptocaPhone Number. Z.oktv a 1 Q- —12I' Summary of Revision: ScC n. —rare- RECEIVED CITY OF TUKWILA OCT 302018 PERMIT CENTFR Sheet Number(s): "Cloud" or highlight all areas of revision including fate re ' ion ibt Received at the Cityof Tukwila Permit Center b : % plel/ Y v ❑ Entered in TRAKiT on W:\Permit Center\ Templates\Forms\Revision Submittal Fornidoc Revised: August 2015 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 't� M / 1 s Plan Check/Permit Number: f 1% — ©d 3'7 Response to Incomplete Letter # Response to Correction Letter # Revision # 1 after Permit is Issued Revision requested by a City Building Inspector or Plans Examiner Project Name: �,� ( C NrC`( PWS NCn As.rri- ►o lea si Project Address: T00 eAt€)C 01b—c1 l —11C 1 IN. LJA'r E. Contact `a5 Contact Person: t ttC CJADZA Phone Number: 20(42.514-1 Summary of Revision: - of r�n( 3-TLcc, oFt %cL 7octc.es RLM1,-) ,s 15 . Sheet Number(s): "Cloud" or highlight all areas of revision includi dat ' of gvisi Received at the City of Tukwila Permit Center by: ❑ Entered in Permits Plus on RECEIVED CITY OF TUKWILP SEP 2 1 2018 PERMIT CENTER H:\Applications\Forms-Applications On Line\2010 Applications\7-2010 - Revision Submittal.doc Revised: May 2011 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite # 100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: b/2-418. 1 Z418. Plan Check/Permit Number: 1\41 8-003 7 O Response to Incomplete Letter # • Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner ❑ Deferred Submittal # Project Name: King County Housing Authority Project Address: 700 Andover Park W Contact Person: T4-4 1106‹..) C-"' 1 Summary of Revision: Phone Number: RECEIVED CITY OF TUKWILA MAR 3 0 2018 PERMIT CENTER O1p • 315.1616 PIa tt tvt bean revised -ID vete' Y5(., SC'►?'(Xft31w41 skir_ 4- S4Z nr,(.Ltir&L Flit SkC,-.s Ivl y+ ka.vt- tabl- *Lived, S' ti aril dad,. A- Cow( I0e,r Fitts ken proided For €nal ehJc.a4fii and a tveit ognip / styo-vrt and da e prow&eL• Sheet Number(s): 5 Sht s -- (ca SOS) "Cloud" or highlight all areas of revision including: r to re iyion i4 . Received at the City of Tukwila Permit Center by: ri Entered in TRAKiT on C.\Users\bill-rlDesktop\Revision Submittal Form.doc Revised: August 2015 Pete Almond Dev Const LLC Ilorne Espanol Contact: Safety & Health Claims & Insurance Washington State Department of Labor & Industries Page 1 of 2 Search L&I A -Z Index Help • by Irl Workplace Rights Trades & Licensing Pete Almond Dev Const LLC Owner or tradesperson Principals Almond, Peter Allen, PARTNER/MEMBER Doing business as Pete Almond Dev Const LLC WA UBI No. 602 951 368 207 Broadway Unit 300 TACOMA, WA 98402-4024 253-576-2102 PIERCE County Business type Limited Liability Company License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. PETEAAD91802 Effective — expiration 09/22/2009— 09/22/2019 Bond CBIC Bond account no. Si4130 Active. Meets current requirements. $12,000.00 Received by L&I Effective date 09/22/2009 09/21/2009 Expiration date Until Canceled Insurance .........._.....__ United Specialty Insurance Com $1,000,000.00 Policy no. TAM -0006873-01 Received by L&I Effective date 09/21/2017 09/21/2017 Expiration date 09/21/2018 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602951368&LIC=PETEAAD91802&SAW= 8/20/2018 Pete Almond Dev Const LLC [rkers' comp / Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID 542,825-00 Doing business as PETE ALMOND DEVELOPMENT & CONS Estimated workers reported Quarter 2 of Year 2018 "4 to 6 Workers" L&I account contact T3 / NATHAN KOZAK (360)902-6243 - Email: KOZN235@Ini.wa.gov Account is current. Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health No inspections during the previous 6 year period. Page 2 of 2 ©Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washingtoi Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602951368&LIC=PETEAAD91802&SAW= 8/20/2018 MECHANICAL SYSTEMS COMMISSIONING NOTES 1. IN ACCORDANCE WITH THE 2015 WASHINGTON STATE ENERGY CODE (WSEC) SECTION C408 BUILDING COMMISSIONING SHALL BE COMPLETED FOR MECHANICAL SYSTEMS* (C403), SERVICE WATER HEATING SYSTEMS (C404), CONTROLLED RECEPTACLES AND LIGHTING SYSTEMS (C405), ENERGY METERING (C409), AND REFRIGERATION (C410). a. *EXCEPTION (C408.2) MECHANICAL SYSTEMS ARE EXEMPT FROM COMMISSIONING PROCESS WHERE THE BUILDING'S TOTAL MECHANICAL EQUIPMENT CAPACITY IS LESS THAN 240,000 BTU/H COOLING CAPACITY AND LESS THAN 300,000 BTU/H HEATING CAPACITY b. CONTRACTORS ARE REQUIRED TO PERFORM PRE -FUNCTIONAL PERFORMANCE TESTING OF ALL EQUIPMENT PRIOR TO FUNCTIONAL PERFORMANCE TESTING BY THE COMMISSIONING AGENT (C408.2.3). CONTRACTORS SHALL PROVIDE THE NECESSARY ASSISTANCE TO THE COMMISSIONING AGENT TO PERFORM COMMISSIONING DUTIES. CONTRACTORS SHALL BE RESPONSIBLE FOR TAKING CORRECTIVE ACTION IF ANY DEFICIENCIES ARE FOUND DURING COMMISSIONING. 2. THE BUILDING COMMISSIONING PROCESS DELIVERABLES ARE AS FOLLOWS: a. COMMISSIONING PLAN (C408.1.2) SHALL BE DEVELOPED BY THE PROJECT'S CERTIFIED COMMISSIONING PROFESSIONAL AND INCLUDED WITH THE CONSTRUCTION DOCUMENTS b. TESTING AND BALANCING (C408.2.2) ALL HVAC SYSTEMS SHALL BE BALANCED BY A LICENSED CONTRACTOR IN ACCORDANCE WITH GENERALLY ACCEPTED ENGINEERING STANDARDS AND SPECIFICATIONS PRIOR TO COMMISSIONING. c. FINAL COMMISSIONING REPORT (C408.1.3) A FINAL COMMISSIONING REPORT SHALL BE COMPLETED AND CERTIFIED BY THE CERTIFIED COMMISSIONING PROFESSIONAL AND DELIVERED TO THE BUILDING OWNER OR OWNER'S AUTHORIZED AGENT. 3. BUILDING DOCUMENTATION AND CLOSE OUT SUBMITTAL REQUIREMENTS (C103.6) OWNER TRAINING BY CONTRACTORS FOR EACH PIECE OF EQUIPMENT OR SYSTEM SHALL INCLUDE: a. SYSTEM/EQUIPMENT OVERVIEW (WHAT IT IS, WHAT IT DOES, AND WHICH OTHER SYSTEMS OR EQUIPMENT DOES IT INTERFACE WITH). b. REVIEW OF AVAILABLE O&M MATERIALS. REVIEW OF THE RECORD DRAWINGS ON THE SUBJECT SYSTEM/EQUIPMENT. c. HANDS-ON DEMONSTRATION OF ALL NORMAL MAINTENANCE PROCEDURES, NORMAL OPERATING MODES, AND ALL EMERGENCY SHUTDOWN AND START-UP PROCEDURES. GENERAL NOTES 1. THESE PLANS ARE SCHEMATIC AND DO NOT SHOW EXACT ROUTING OR EVERY OFFSET WHICH MAY BE REQUIRED. THE HVAC CONTRACTOR IS TO COORDINATE WITH ALL OTHER TRADES AND IS TO VERIFY ALL CLEARANCES BEFORE COMMENCING WORK. 2. MATERIALS, METHODS, AND INSTALLATION SHALL COMPLY WITH THE PROVISIONS OF THE LATEST EDITION OF THE WASHINGTON STATE ENERGY CODE (WSEC), INTERNATIONAL MECHANICAL CODE (IMC) WITH WASHINGTON STATE AMENDMENTS, INTERNATIONAL BUILDING CODE (IBC) WITH WASHINGTON STATE AMENDMENTS, INTERNATIONAL FIRE CODE (IFC) AND OTHER APPLICABLE STATE AND LOCAL CODES AND ORDINANCES. 3. DUCT CONSTRUCTION AND HANGINGS SHALL COMPLY WITH THE LATEST IMC AND WITH CURRENT SMACNA STANDARDS. 4. JOINTS OF DUCT SYSTEM SHALL BE SEALED WITH DUCT MASTIC. 5. DUCTS SHALL BE INSULATED AS INDICATED ON PLANS TO MEET THE REQUIREMENTS OF CURRENT CODES AND SPECIFICATIONS. 6. FLEXIBLE DUCTS SHALL ONLY BE USED WHERE SHOWN AND SHALL NOT EXCEED 6 FT IN LENGTH UNLESS NOTED OTHERWISE. 7. PROVIDE EARTHQUAKE RESTRAINT FOR HVAC EQUIPMENT IN ACCORDANCE WITH THE CURRENT IBC. 8. PIPING PENETRATIONS OF FIRE RATED WALLS OR FLOOR SHALL BE SLEEVED AND FIRE STOPPED WITH LISTED MATERIALS SO AS TO MAINTAIN THE INTEGRITY AND RATING OF THE FLOOR OR WALL. 9. HVAC EQUIPMENT, VALVES, AND DAMPERS SHALL BE LOCATED IN EASILY ACCESSIBLE LOCATIONS, UNLESS SHOWN ON ARCHITECTURAL DRAWINGS. REQUIRED ACCESS PANELS SHALL BE PROVIDED BY THE HVAC CONTRACTOR AND INSTALLED BY THE GENERAL CONTRACTOR. 10. SEE ARCHITECTURAL DRAWINGS FOR LOCATION OF EXPOSED DUCTWORK AND GRILLES. 11. ALL DUCT DIMENSIONS INDICATE FREE AREA. SOUND LINING AND EXTERIOR INSULATION ARE LABELED AS SUCH. ENERGY CODE GENERAL NOTES 1. SEE MECHANICAL AND PLUMBING SCHEDULES FOR EQUIPMENT TYPE, CAPACITY AND EFFICIENCY. 2. PROVIDE THERMOSTAT CONTROLS CAPABLE OF A FIVE (5) DEGREE DEADBAND BETWEEN HEATING AND COOLING. 3. PROVIDE AUTOMATIC SETBACK CONTROLS WITH NIGHT SETBACK AND SEVEN (7) DIFFERENT DAY TYPES. 4. PROVIDE DAMPERS FOR OUTSIDE AIR INTAKES AND EXHAUST FANS WHICH CLOSE AUTOMATICALLY WHEN THE SYSTEM IS OFF, EXCEPT FOR THOSE SYSTEMS WHICH OPERATE CONTINUOUSLY WITH LESS THAN 20 CFM/SF LEAKAGE FOR BAROMETRIC DAMPERS, AND LESS THAN 10 CFM/SF LEAKAGE FOR MOTORIZED DAMPERS. 5. PROVIDE MICROPROCESSOR -BASED THERMOSTAT FOR HEAT PUMP CONTROLS. 6. PROVIDE A MEANS OF BALANCING EVERY AIR SUPPLY OUTLET AND AIR OR WATER TERMINAL DEVICE. 7. SIMULTANEOUS HEATING AND COOLING IN A ZONE IS NOT PERMITTED. 8. SEAL TRANSVERSE SEAMS OF ALL DUCTWORK. 9. SEALING TO CONTROL BUILDING ENVELOPE AIR LEAKAGE AND AIR TIGHTNESS TESTING IS REQUIRED PER 2015 SEC SECTIONS C402.5.1 THROUGH C402.5.8. 10. DUCTWORK AND PLENUMS SHALL BE THERMALLY INSULATED IN ACCORDANCE WITH 2015 SEC SECTION C403.2.8. 11. ALL PIPING SHALL BE THERMALLY INSULATED TO MEET SPECIFICATIONS SET IN PIPE INSULATION TABLE ON SHEET P0.01 PLUMBING SCHEDULE AND GENERAL NOTES. 12. ALL ELECTRIC MOTORS GREATER THAN 1.0 HP SHALL MEET THE REQUIREMENTS OF 2015 SEC SECTION C403.2.14. 13. WATER HEATING EQUIPMENT AND STORAGE TANKS SHALL MEET THE MINIMUM REQUIREMENTS OF TABLE C404.2 OF THE 2015 SEC. MECHANICAL LEGEND SYMBOL DESCRIPTION IHP-1 O ! \ SIZE 1 FLOW 'L8"x10 111111111111111 (CO2 .Q SECTION/ELEVATION VIEW DETAIL VIEW EQUIPMENT TAG SHEET NOTE TAG REVISION TAG DIFFUSER/GRILLE TAGE RECTANGULAR FREE AREA DUCT DIMENSIONS (8" WIDTH x 10" DEPTH) ROUND DUCT FREE AREA DIMENSIONS (6" DIAMETER) FLEX DUCT AIR DIRECTION SUPPLY DUCT IN/OUT OF PAGE EXHAUST/RETURN DUCT IN/OUT OF PAGE THERMOSTAT CO2 SENSOR DESCRIPTION ENVELOPE PENETRATION PUMP SUPPLY/EXHAUST FAN PRESSURE GAGE TEMPERATURE GAGE TURNING VANES CONNECT TO EXISTING MECHANICAL ABBREVIATIONS AFF ARCH BLDG BMS BTUH CD CLG CTE CW CWR CWS DCVA DDC DHW DIA DEN ELEV EWT FC FCO FLR FP GC GEO GPM GWB HTG HW HWR HWS INV LAV MECH NFA OHP POC PLUM PSI REF RF RPBP TYP UV VTR WC WCO WHF ABOVE FINISHED FLOOR ARCHITECT BUILDING BUILDING MANAGEMENT SYSTEM BRITISH THERMAL UNITS PER HOUR CONDENSATE COOLING CONNECT TO EXISTING COLD WATER CHILLED WATER RETURN CHILLED WATER SUPPLY DOUBLE CHECK VALVE ASSEMBLY DIRECT DIGITAL CONTROL DOMESTIC HOT WATER DIAMETER DOWN EXISTING ELEVATION ENTERING WATER TEMPERATURE FAN COIL FLOOR CLEANOUT FLOOR FIRE PROTECTION GENERAL CONTRACTOR GEOTHERMAL GALLONS PER MINUTE GYPSUM WALLBOARD HEATING HOT WATER HOT WATER RETURN HOT WATER SUPPLY INVERT LAVATORY MECHANICAL NET FREE AREA OUTDOOR HEATPUMP POINT OF CONNECTION PLUMBING POUNDS PER SQUARE INCH REFER/REFERENCE RELIEF FAN REDUCED PRESSURE BACKFLOW PREVENTER TYPICAL UNIT VENTILATORS VENT THRU ROOF WATER CLOSET WALL CLEAN OUT WHOLE HOUSE FAN INDOOR HEAT PUMPS TAG 00 -INFO -LOCATION MANUFACTURER MODEL UNIT TYPE OUTDOOR UNIT COOLING CAPACITY HEATING CAPACITY DIMENSIONS WEIGHT ELECTRICAL NOTES HEIGHT WIDTH DEPTH VOLTS/PHASE MCA IHP-1 OPEN OFFICE 200 MITSUBISHI PLFY-P12NCMU-E CEILING CASSETTE OHP -1 12,000 Btu/h 13,500 Btu/h 0' - 10 5/8" 2' - 1 5/8" 2' - 1 5/8" 37 Ib 208VAC/ 1 PH 0.35 1 IHP-2 OPEN OFFICE 200 MITSUBISHI PLFY-P12NCMU-E CEILING CASSETTE OHP -1 12,000 Btu/h 13,500 Btu/h 0' - 10 5/8" 2' - 1 5/8" 2' - 1 5/8" 37 Ib 208VAC/ 1PH 0.35 1 IHP-3 OPEN OFFICE 200 MITSUBISHI PLFY-P12NCMU-E CEILING CASSETTE OHP -1 12,000 Btu/h 13,500 Btu/h 0' - 10 5/8" 2' - 1 5/8" 2' - 1 5/8" 37 Ib 208VAC/ 1PH 0.35 1 IHP-4 OFFICE 204 MITSUBISHI PKFY-P06NBMU-E2 WALL CASSETTE OHP -1 6,000 Btu/h 6,700 Btu/h 0' - 11 5/8" 2' - 8 3/16" 0' - 8 3/16" 22 Ib 208VAC/ 1PH 0.19 1 IHP-5 OFFICE 205 MITSUBISHI PKFY-P06NBMU-E2 WALL CASSETTE OHP -1 6,000 Btu/h 6,700 Btu/h 0' - 11 5/8" 2' - 8 3/16" 0' - 8 3/16" 22 Ib 208VAC/ 1PH 0.19 1 IHP-6 OFFICE 206 MITSUBISHI PKFY-P06NBMU-E2 WALL CASSETTE OHP -1 6,000 Btu/h 6,700 Btu/h 0' - 11 5/8" 2' - 8 3/16" 0' - 8 3/16" 22 Ib 208VAC/ 1 PH 0.19 1 IHP-7 CONFERENCE 203 MITSUBISHI PLFY-P08NCMU-ER4 CEILING CASSETTE OHP -1 8,000 Btu/h 9,000 Btu/h 0' - 10 5/8" 2' - 1 5/8" 2' - 1 5/8" 34 Ib_ , 208VAC/ 1 PH 0.29 1 1. PROVIDE HEAT PUMP WITH INTEGRAL CONDENSATE PUMP GOBI II OR EQUIVALENT (20 dBA @ 3FT). CONTRACTOR SHALL COORDINATE CONDENSATE PIPING ROUTING TO NEAREST APPROVED DRAIN LOCATION. 2. IHPS TO BE CONTROLLED BY SIMPLE MA CONTROLLER (PAC-YT53CRAU) OR OTHER APPROVED THERMOSTAT. OPEN OFFICE (IHP1, IHP2, IHP3) SINGLE ZONE TO BE CONTROLLED BY ONE THERMOSTAT LOCATED PER SHEET M1.00. 3. SEE SHEET M1.00 FOR DETAILS ON MODIFCATION TO EXISTING HEAT PUMP CONTROL WIRING. OUTDOOR HEAT PUMPS TAG LOCATION/SERVICE MANUFACTURER MODEL COOLING CAPACITY HEATING CAPACITY COP cLD47F EER WEIGHT ELECTRICAL NOTES VOLTS/PHASE MCA OHP -1 ROOF/TI SPACE MITSUBISHI PURY-P72TLMU-A(-BS) 72,000 Btu/h 80,000 Btu/h 4.30 14.8 444 Ib 208, 3-PHASE, 60HZ 24 1, 2, 3, 4 1. COORDINATE ROOF LOCATION PER STRUCTURAL. 2. INSTALL VRF OUTDOOR UNIT PER MITSUBISHI'S ROOF MOUNT INSTRUCTIONS. INCLUDE VIBRATION (ISOLATION SPRINGS AND FLEXIBLE REFRIGERANT CONNECTIONS PER DETAIL 4 ON SHEET M2.00. 3. ALL REFRIGERANT PIPING INSULATION TO BE 1" THICK WALL WITH VAPOR BARRIER (PDM) OR EQUIVALENT. BC CONTROLLERS TAG SERVICE MANUFACTURER MODEL VOLTS/PHASE CURRENT DRAW (AMPS) WEIGHT (LBS) NOTES BC -1 OHP -1 MITSUBISHI CMB-P108NU-G1 208V/1 PHASE 0.68 84 1, 2 1. PROVIDE ACCESSORY CONDENSATE PUMP FOR CONDENSATE MANAGEMENT AND ROUTE CONDENSATE TO APPROVED LOCATION PER 2015 UPC 2. CAP ADDITIONAL PORTS FOR FUTURE USE ENERGY RECOVERY VENTILATORS TAG MANUFACTURER MODEL FLOW ENTHALPY RECOVERY EFFICIENCY TEMPERATURE RECOVERY EFFICIENCY WEIGHT VOLTS/PHASE 04-ELEC-MCA NOTES ERV -1 LOSSNAY LGH-F470RX5-E 470 CFM 64% 69% 119.00 Ib 208V / 1PH 3.1 1,2 1. RUN ON EXTRA HIGH SPEED, CONTROL WITH EXISTING VRF CONTROLLER. 2. OUTSIDE AIR DAMPERS TO BE ENERGIZED OPEN WHEN UNIT IS ON AND CLOSE WHEN UNIT IS POWERED OFF. DIFFUSERS, LOUVERS, & GRILLES TAG MANUFACTURER MODEL TYPE FINISH SIZE R1 SHOEMAKER 830 PERFORATE 4 -WAY T -BAR CEILING RETURN GRILLE SEE ARCH 24" x 24" S1 SHOEMAKER 700 MA 4 -WAY T -BAR CEILING SUPPLY DIFFUSER SEE ARCH 24"x24" S2 SHOEMAKER 903 AIRFOIL DOUBLE DEFLECTION SUPPLY GRILLE SEE ARCH SEE PLANS VENTILATION RATES SPACE AREA (SF) OCCUPANCY (# PEOPLE) EXHAUST RATE PEOPLE OUTDOOR AIR SUPPLY RATE Rp (CFM/PERSON) AREA OUTDOOR AIR SUPPLY RATE Ra (CFM/SF) MIN VENTILATION (CFM) SUPPLY (CFM) EXHAUST (CFM} OPEN OFFICE 200 2191 12 Btuh 5 0.06 195 200 240 CONFERENCE 203 275 14 13.8 /SF x 5 0.06 90 115 115 OFFICE 204 114 1 Btuh 5 0.06 15 20 0 OFFICE 205 111 1 23.0 /SF x 5 0.06 15 20 0 OFFICE 206 111 1 Btuh 5 0.06 15 20 0 COPY ROOM 207 114 0 1 CFM/SF 0 0 115 EXHAUST 1"AIR GAP UNDER DOOR 115 WEATHERIZATION 211 153 NA Btuh 0 0.12 20 20 0 MAINTENANCE 212 103 NA 17.0 /SF x 0 0.12 15 15 0 CORRIDOR 472 12 Btuh 0 0.12 60 60 0 TOTAL I 470 470 BASIS OF DESIGN PROJECT SCOPE: CONVERT HEATED STORAGE TO OFFICE SPACE. PROJECT WILL ADD HIGH EFFICIENCY VARIABLE REFRIGERANT FLOW (VRF) HEAT PUMP SYSTEM AND ENERGY RECOVERY VENTILATION SYSTEM. SEE SEQUENCE OF OPERATIONS SPEC FOR DETAILS. BELOW ARE KEY DETAILS. 1. INTEGRATE WITH EXISTING SYSTEM: A. VRF SYSTEM - INTEGRATE NEW VRF WITH EXISTING BUILDING VRF SYSTEM CONTROL B. DOAS ERV - CONTROL ERV WITH EXISTING VRF CONTROLS (GB -50) 2. CEILING FANS - CEILING FANS LOCATED IN OPEN OFFICE SPACE. CEILING FANS TO BE CONTROLLED WITH WALL MOUNTED FAN CONTROLLERS. SEE ELECTRICAL SCHEDULE 4. EXISTING STRUCTURE AND SYSTEMS:.: A. DEMO PLAN SEE M0.02 FOR MODIFICATIONS TO EXISTING SYSTEMS. CONTRACTORS TO FIELD VERIFY EXISTING STRUCTURE AND SYSTEMS AND TAKE APPROPRIATE ACTION TO AVOID OR MODIFY AS NEEDED. ISDepartment of Planning and Development SEATTLE ENERGY CODE instructions: bee reverse Y V v;ozii:vaI kriCecincal pi/tun-thing Bit Gas Piping C;iy of Tukwila !D"VIS(OtN FILE COPY Permit No. M1' t° /71 Plan review a :p; rvci 1s subject to errors and ©r niss,ons. Approval of Cor ,u o:1 documents coos n':I ce...'hitorize the violation Ci Ct y cdtipted CG or crdin non R .ccipt of approved Field Copy and condiilons is ackno Jledi;od: By: Date: 5 Is City of Tukwila BUILDING DIVISION • n REVISIONS No changes sh:a`I bo m=ade to the scope of Work without prior approval of Tukwila Buildiro D(vislon t' OTE: Revisions will require a nc» / 1 +, r1 t.+rrt t`2 and may include Project Address: + 700 ADOVER PARK WEST TUKWILA, WA 98188 Date of this submittal 2/23/2018 Project Number. ` Permit Number. HEATING EQPMT'SIZING OPEN OFFICE January2011 Building Component Description Including U -Factor or F -Factor Heat Loss Factor (HLF = U x 46° t) (1) Component Square Feet (SF) Linear Feet (LF) Cubic Feet (CF) (2) Component Heat Loss (HLF x SF, LF or CF) A. Window, Glass Block Single, uncertified (U = 1.20 ) Double, uncertified (U = 0.92 ) 55.2 /SF x 42.3 /SF x SF = Btuh SF = Btuh Sliding & Swinging NFRC certified (U = 0.32 ) 14.7 /SF x SF = Btuh Glass Door NFRC certified (U = 0.30 ) 13.8 /SF x 96 SF = 1325 Btuh Skylight Skylight, single, uncertified (U = 1.58 ) 72.7 /SF x SF = Btuh Garden Window Skylight, double, uncertified (U = 1.05 ) 48.3 /SF x SF = Btuh Skylight, NFRC certified (U = 0.50 ) 23.0 /SF x SF = Btuh Garden window, single, uncertified (U = 2.60 ) 119.6 /SF x SF = Btuh Garden window, double, uncertified (U = 1.81 ) 83.3 /SF x SF = Btuh Other _STOREFRONT (U = 0.38 ) 17.5 /SF x 190 SF = 3321 Btuh Other (U = ) /SF x SF = Btuh B. Opaque Door Wood, in wood frame, uncertified (U = 0.46 ) 21.2 /SF x SF = Btuh Foam ins., in metal frame, uncertified (U = 0.37 ) 17.0 /SF x SF = Btuh Foam ins., in wood frame, uncertified (U = 0.16 ) 7.4 /SF x SF = Btuh Opaque door, NFRC certified (U = 0.20 ) 9.2 /SF x SF = Btuh Other (U = ) /SF x SF = Btuh C. Roof/Ceiling None (U = 0.400 ) 18.4 /SF x SF = Btuh Insulation R-38 (U = 0.031 ) 1.4 /SF x SF = Btuh (OPAQUE area only, does not include R49 standard or R-38 full depth (U = 0.027) R-60 (U = 0.025) 1.2 /SF x 1.2 /SF x 3260 SF = 4049 Btuh SF = Btuh skylight area) R -38+12.5d (U = 0.019 ) 0.9 /SF x SF = Btuh D. Wall Insulation, above and below None (U = 0.250 ) R-13, wood studs (U = 0.082) 11.5 /SF x 3.8 /SF x SF = Btuh SF = Btuh grade R-19, wood studs (U = 0.062) 2.9 /SF x SF = Btuh (OPAQUE area only, does not include R-21 cavity + R-10 headers, wood (U = 0.051 ) R-19 cavity + R-5 cont., wood studs (U = 0.046) 2.3 /SF x 2.1 /SF x SF = Btuh SF = Btuh window & door area) R-11, metal studs (U = 0.132) 6.1 /SF x SF = Btuh R-19, metal studs (U = 0.109 ) 5.0 /SF x SF = Btuh R-19 cavity + R-8.5 cont., metal stu (U = 0.057) 2.6 /SF x SF = Btuh R-13 cavity + R-10 cont., metal studs (U = 0.055) 2.5 /SF x SF = Btuh R -_5+12.5c1_ (U = 0.045 ) 2.1 /SF x 1558 SF = 3225 Btuh E. Floor Over None (U = 0.134) 6.2 /SF x SF = Btuh Unheated Space R-19 (U = 0.041 ) 1.9 /SF x SF = Btuh R-30 (U = 0.029) 1.3 /SF x SF = Btuh R-38 (U = 0.025 ) 1.2 /SF x SF = Btuh R-38 Floor over exposed (U = 0.034) 1.6 /SF x SF = Btuh F. Slab On Grade Floor None (F = 0.730 ) 33.6 /LF x 112 LF = 3761 Btuh Perimeter Insulation R-10 (F = 0.540 ) 24.8 /LF x LF = Btuh (use linear ft, NOT sq.ft) R-_ (F = ) /LF x LF = • Btuh G. Basement Floor None (F = 0.460 ) 21.2 /LF x LF = Btuh (for heated space ONLY) R-_ (F = ) /LF x LF = Btuh H. Infiltration Pre -1980 (.018 x 1.2 ACH) 1.0 /CF x CF = Btuh (use cubic ft, NOT sq.ft) 1980-2010 (.018 x 0.6 ACH) 0.5 /CF x 45640 CF = 22820 Btuh Post -2010 (.018 x 0.35 ACH) 0.3 /CF x CF = Btuh (4) DHL/SF: DHL divided by( 2400 Heated floor area in SF) (3) Total = Design Heating Load (DHL) in Btuh = 38501 Btuh = 16 Btuh/SF or 4.7 Watts/SF If electric, divide by 3.413 for DHL in watts = 11281 Watts (Typical values for DHUSF for new construction are 8 Btul✓SF or 2.5 Watts/SF.) (5) Space Heating Equipment Sizing Limits (6) Proposed Space Heating Equipment Minimum required size = DHL x 1.0 = 38501 Btuh or 11281 Watts Manufacturer. Model #. Maximum allowed size = DHL x 1.5 = 57751 Btuh or 16921 Watts Heating output Btuh Efficiency AFUE Watts HSPF 1. PROJECT HVAC EQUIPMENT SIZED FOR COOLING LOAD CORRECTION LTR# 1 4 0 RUCerg LLER ARCHITECTURE INTERIORS PLANNING VIZLAB 275 FIFTH STREET, SUITE 100 BREMERTON, WA 98337 360-377-8773 RFMARCH.COM ECOTOPE o°° NT I• 00>o � Gj�PCF WAS h ' 7 % f Ofr‘fr z 0 >is Q 0 z Ct aw cDO Ow 0 >I= 0 0 oz 0 o Ue J 2 m 0 0 ti PROJECT # 2017036 PERMIT SET ISSUE DATE REVISION SCHEDULE 8/30/2018 E\/ISIQN N0. REVIEVVED FOR CODE COMPLIANCE APPROVED NOV 06 2018 City of ukwila BUILDING DIVISION nEceiven CITY OF TUKWILA OCT 30 MB PERMIT CENTER GENERAL NOTES AND MECHANICAL SCHEDULE SHEET # M0.0 1 F 4 ) WEATHE MAINTENANCE 'STORAGE 4 4l e "88 eA) 40A . & Or., -0 dik.a,..... A41644. . „Or4 , warini, • : 4T.• 0 141 fe,... Jo WW4ii IT . *Ay* V.1, 04 ror A ‘!toy.. , I.4. i , y i t tr A __ .. 4 'W • WO 4 '*-• "db. 0 . 1) 111. 1 w IA r******44t0** *Ar*--**---; 2 0 SHEET NOTES 1 MOVE EXISTING DUCTWORK OUTSIDE OF ENCLOSED STORAGE AREAS. SEE SHEET M1.00 FOR NEW DUCT PLACEMENT. 1 MilDSLOMMISK2.019011011011011611165.1911161442SSIVI 7"r H1 •-• F1 RECE CITY OF 1 Ricerg LLER ARCHITECTURE INTERIORS PLANNING VIZLAB 275 FIFTH STREET, SUITE 100 BREMERTON, WA 98337 360-377-8773 RFMARCH.COM ECOTOPE PROJECT # 2017036 PERMIT SET ISSUE DATE REVISION SCHEDULE 8/30/2018 1 OFFICE REVISION 08/30/18 REVIEWED FO CODE COMPLIAN APPROVED p CHANICAL - DEMO N NOV 06 2018 City of Tukwila DING DIVISIONI OCT 30 2018 PERMIT CENTER SHEET # MO NI 02 GENERAL NOTES A B REFRIGERANT PIPING SHALL BE INSULATED WITH MINIMUM 1" THICK WALL PIPING INSULATION, INCLUDING WHERE SUPPORTED ON ROOF. CONDENSATE DRAINS FROM INDOOR UNITS SHALL BE ROUTED TO SINGLE LOCATION. PROVIDE CONDENSATE PUMP WHERE NECESSARY. COORDINATE WITH MECHANICAL CONTRACTOR. C COORDINATE ALL NEW DUCTWORK INSTALLATION WITH EXISTING DUCTWORK AND EQUIPMENT IN AREAS OF WORK WEATHERIZATION 211 S2 6"x4" 20 CFM 24"x24" 100 CFM 1-1111 8" (11 -24"x24' FICE BC CONTROLLER REFRIGERANT PIPING S2 6"x4" _. 2 6"x4" 20 CFM A 20 CFM 6"x4" : 20 CFM X1111 o ..----..-_ .41.1 0 SHEET NOTES 1 INSTALL RECEPTACLE FOR CONDENSATE PUMP ABOVE T -BAR. ROUTE CONDENSATE TO EXISTING WALL OPEN SITE DRAIN IN EAST OFFICE DIVIDER WALL. 2 ELECTRICAL TO PROVIDE RECEPTABLE FOR SUMP PUMP FOR BC CONTROLLER 3 10' MIN SEPARATION BETWEEN SUPPLY AND EXHAUST LOUVERS 4 4 -WAY THROW DIFFUSER 5 ROUTE BC REFRIGERANT PIPING & POWER THROUGH EXISTING ROOF PENETRATION 6 ERV LOUVER 1SF MIN NFA. PROVIDE MECHANICAL DAMPER 7 SERVICE ACCESS AREA 8 1" UNDERCUT DOOR FOR RETURN AIR 9 CONTRACTOR TO FIELD VERIFY LOCATION OF SPRINKLER HEADS IN THIS AREA. MODIFY SPRINKLER PIPING AND SPRINKLER HEAD LOCATIONS AS NEEDED TO ENSURE SPRINKLER HEAD OPERATION IS NOT AFFECTED BY NEW EQUIPMENT OR DUCTWORK. 10 EXISTING DUCTWORK AND SUPPLY AIR DIFFUSERS TO BE MOVED OUTSIDE OF ENCLOSED AREAS AS NEEDED. SEE DEMO PLAN SHEET M0.02. 11 ADD BALANCING DAMPERS AT ALL BRANCHES (TYP) 12 REROUTE WIRING TO EXISTING THERMOSTATS NEW LOCATION 13 CEILING FANS LOCATED IN OPEN OFFICE SPACE. TO BE CONTROLLED WITH WALL MOUNTED FAN CONTROLLERS. SEE ELECTRICAL SCHEDULE 14 EXPOSED REFRIGERANT PIPING TO BE INSTALLED IN ORDERLY LAYOUT. 15 EXISTING OPEN SITE FIELD DRAIN. CONTRACTOR TO FIELD VERIFY. H1 DSO icerg ILLER ARCHITECTURE INTERIORS PLANNING VIZLAB 275 FIFTH STREET, SUITE 100 BREMERTON, WA 98337 360-377-8773 RFMARCH.COM ECOT❑PE 0 o°o PNT I 0 /°o°o R pGj�` OFWASy��'�/% Asc O �COSTE\< ,�pp0 OO�os ONAL k- 00- fotz&pg PROJECT # 2017036 PERMIT SET ISSUE DATE REVISION SCHEDULE 8/30/2018 1 OFFICE REVISION 08/30/18 REVIEWED gent rr CODE COMPLI�I' APPROVEEfLOORPLAN HANICAL - TI NOV 0 6 2010 City of Tukwila BUILDING DIVISION RECENED CITY OF TUK iILA OCT 3 0 2018 PERMIT CENTER SHEET # M1 .00 ii. 0 SHEET NOTES 1 ROUTE REFRIGERANT AND POWER THROUGH EXISTING ROOF PENETRATION. ADD WEATHER HOOD COVER, SEAL TIGHTLY 2 COORDINATE FINAL PLACEMENT OF OUTDOOR UNIT WITH STRUCTURAL ENGINEER 3 REFRIGERANT PIPING ON ROOF TO BE INSTALLED WITH 1" THICK WALL INSULATION AND FULL INSULATION VALUE PIPE MOUNTS. INCLUDE PVC SLEEVING TO MITIGATE BIRD AND VERMIN DAMAGE SERVICE ACCESS AREA J r I 1 (FI Ric§rerg LLER ARCHITECTURE INTERIORS PLANNING VIZLAB 275 FIFTH STREET, SUITE 100 BREMERTON, WA 98337 360-377-8773 RFMARCH.COM ECOTOPE z 0 >ma < 00 z 1== LLI Ct aw zQ === a„. cn cn O V in= 0 Oz 0 (19 Z � O O ti PROJECT # 2017036 PERMIT SET ISSUE DATE REVISION SCHEDULE 8/30/2018 REVIEWED FOR CODE COMPLM APPROVEDFLAN ANICAL - ROOF NOV 0 6 2018 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA OCT 30 208 PERMIT CENTER SHEET # M 1.01 MOUNT TO SIP PANEL ROOF ACCORDING TO SIP MANUFACTURER'S INSTRUCTIONS ROOF, SEE ARCH FOR DETAILS NEOPRENE VIBRATION ISOLATORS, SIZED FOR 1/2" TOTAL STATIC DEFLECTION 1/2" THREADED ROD, TYPICAL HVAC UNIT NOTES: LOCK NUT, TYPICAL 1. EQUIPMENT MOUNTING AND CONNECTION AND SEISMIC RESTRAINTS TO BE DESIGNED AND STAMPED BY LICENSED WASHINGTON STATE ENGINEER AS A DEFERRED SUBMITTAL O VIBRATION ISOLATION 12" = SIDE VIEW GENERAL NOTE: SHEET METAL HOOD WATER PROOF, SEE ARCH SPECS FOR WATER -PROOFING REQUIREMENTS FOAM IN OPENING /--- AFTER REFRIGERANT PIPING IS INSTALLED ROOF OPENING REFRIGERANT PIPING TO OUTDOOR UNIT (TYP) REFRIGERANT PIPING TO BC CONTROLLER (TYP) SEE ARCH DRAWINGS FOR WEATHER -PROOFING DETAILS PRE -FABRICATED ROOF CURB NOTES: 1. REFRIGERANT PIPES TO BE INDIVIDUALLY INSULATED (1"). 2. MECHANICAL CONTRACTOR SHALL COORDINATE SLEEVES AND PENETRATIONS WITH GENERAL CONTRACTOR 3. SEE STRUCTURAL DRAWINGS FOR PENETRATION SEPARATION AND LOCATION REQUIREMENTS. REFRIGERANT PIPING ROOF !-I" PENETRATION 12" = FRONT VIEW 1. PROVIDE VRF OUTDOOR UNIT BASE DESIGN AS A DEFERRED SUBMITTAL. DESIGN SHALL BE STAMPED BYA LICENSED WASHINGTON STATE STRUCTURAL ENGINEER. NUMBER NOTES: 1. PROVIDE STRUCTURAL INTERSTITIAL ANGLE IRON MOUNTING MEMBER OR SIMILAR ATTACHED DIRECTLY TO BOTTOM OF UNIT MOUNTING FLANGE AND PROVIDE CROSS BRACING FOR RIGIDITY. ENSURE IT CARRIES FULL MOUNTING FOOT WIDTH ON UNIT. FINAL SPECIFICATION OF MEMBER BY STRUCTURAL ENGINEER OF RECORD. 2. PROVIDE BRAIDED COPPER FLEXIBLE CONNECTOR, R410A RATED, 650PSI MAX WORKING PRESSURE, PACKLESS INDUSTRIES OR EQUAL ON ALL MAIN PIPING DOWNSTREAM OF TWINNING KITS/CONVERGING FITTINGS PRIOR TO PENETRATION THROUGH ROOF. 3. PIPE ROOF CURB, FLASHED AND SEALED WATER TIGHT, PROVIDE FLEXIBLE WATER TIGHT COLLAR TO ALLOW FOR MOVEMENT WHERE PIPE ENTERS CURB. DO NOT ENTER PIPE CURB FROM VERTICAL DIRECTION. COORDINATE OPENING WITH GENERAL CONTRACTOR. 4. TYPICAL BASE SUPPORT POSTS, SECURELY ANCHORED TO BUILDING STRUCTURE BELOW, QUANTITY, SIZE, AND CARRYING CAPACITY DETERMINED BY STRUCTURAL ENGINEER OF RECORD. 5. STRUCTURAL ANGLE IRON BASE MOUNTING FRAME WITH CROSS MEMBERS FOR RIGIDITY - FINAL SIZING BY STRUCTURAL ENGINEER OF RECORD. 6. VIBRATION SPRING SLR TYPE ISOLATORS (MASON INDUSTRIES OR EQUIV.) WITH RUBBER BASE PADS, SECURELY FASTENED TO STRUCTURAL BASE AND TO VRF UNIT INTERSTITIAL SUPPORT STEEL. SPRING ISOLATOR TO PROVIDE MINIMUM 1" DEFLECTION OR 10 TIMES THE STATIC DEFLECTION OF THE ROOF DECK FROM EQUIPMENT WEIGHT - DETERMINED BY STRUCTURAL ENGINEER OF RECORD. AT A MINIMUM, PROVIDE SPRING ISOLATORS AT EACH EQUIPMENT BASE MOUNTING HOLE LOCATION. 7. IF REQUIRED, ONLY SUPPORT LATERAL PIPE EMANATING FROM VRF UNIT CONNECTIONS BY CROSS MEMBER SUPPORT THAT IS ATTACHED DIRECTLY TO VRF UNIT MOUNTING ANGLE IRON FRAME ABOVE SPRING ISOLATORS. DO NOT ATTACH ANY PIPING TO LOWER FIXED SUPPORT BASE. 8. USE NEOPRENE ISOLATION COLLARS ON PIPE CLAMS WHEN FASTENING PIPING TO SUPPORTS. 9. USE LONG RADIUS SWEEPING COPPER ACR TUBE PIPE BENDS WHERE PIPE ENTERS BUILDING AT FIRST ELBOW INTO CEILING SPACE TO MINIMIZE REFRIGERANT FLOW NOISE AND VIBRATION. 10. ALL ELECTRICAL CONNECTIONS TO UNITS TO BE VIA FLEXIBLE CONDUIT, PROVIDE SUFFICIENT SLACK TO ALLOW FOR UNIT MOVEMENT ON SPRING ISOLATORS. 11. ENSURE CROSS MEMBERS OF INTERSTITIAL FRAME AND BOTTOM SUPPORT FRAME ARE NOT DIRECTLY BELOW ENDS OF MODULES IN ALL LOCATIONS AND DO NOT BLOCK DRAINAGE WEEP HOLES IN BOTTOM OF UNIT CASING, FAILURE TO DO THIS MAY RESULT IN ICE DAMMING/BUILDUP BENEATH UNIT AND SUBSEQUENT BUILDUP OF ICE IN BOTTOM OF UNIT CASING BELOW COIL AND POTENTIAL DAMAGE TO BOTTOM OF COIL. 12. WHEN SELECTING SPRING ISOLATORS ALWAYS CONSIDER WEIGHT DISTRIBUTION BY REFERENCING EQUIPMENT WEIGHT AND CENTER OF GRAVITY. NEAR RIGHT ENDS OF UNITS (VIEWED FROM FRONT PANEL) SPRING WEIGHT CAPACITY MAY BE LARGER. IF HIGHER SPRING WEIGHT CAPACITY IS REQUIRED VS OTHER SPRING LOCATIONS, CONSIDER AN ADDITIONAL SPRING OF EQUAL "K" VALUE (lbs/in) NEAR RIGHT END OF LAST MODULE. IN GENERAL IT IS RECOMMENDED TO SELECT ALL MOUNTING SPRINGS OF EQUIVALENT"K" VALUE (lbs/in). ® VRF OUTDOOR UNIT MOUNTING DETAIL 12 =1 0 CONICAL OR LO - LOSS 45 DEGREE BOOT FITTING WITH VOLUME DAMPER ROUND NECK - DIFFUSER (TYP) ROUND SHEET METAL DUCT FLEXIBLE DUCT 7' MAX LENGTH W/ ONE 90 DEGREE BEND WALL HUNG INDOOR UNIT INDOOR UNIT DISCONNECT SHALL BE RECESSED IN WALL, SUBMIT DISCONNECT TO ECOTOPE FOR REVIEW MOUNT UNIT TO WALL WITH MANUFACTURER'S BRACKET, ALL PIPING AND ELECTRICAL CONNECTIONS SHALL BE MADE BEHIND THE UNIT IN THE INTERIOR WALL. UNIT SHALL SIT FLUSH ON THE WALL INTERIOR FRAMED WALL NOTES: 1. PROVIDE WITH CONDENSATE PUMP IF NECESSARY. ‘-'1 TYPICAL WALL HUNG UNIT DETAIL 12=10 SQUARE TO ROUND TRANSITION VD 45 DEGREE - LO -LOSS BOOT TAP OR CONICAL TAP REDUCER TO MATCH DIFFUSER NECK SIZE IF BRANCH DUCT IS OVERSIZED. LOCATE AT CONNECTION TO DIFFUSER SPLITTER DAMPER WHERE SHOWN. DO NOT USE ON VAV SYSTEMS VD TRANSITION 15 DEGREE TYPICAL, 30 DEGREE MAXIMUM TYPICAL SQUARE NECK DIFFUSER SIZE OF DUCT DROP TO MATCH DIFFUSER NECK SIZE MIN 36" BEFORE AND AFTER ELBOW CENTERLINE RADIUS EQUALS 1.5 TIMES WIDTH AIRFLOW VD VD \ VD ) NOTES: 1. PROVIDE DUCT LINER AND/OR EXTERNAL DUCT INSULATION AS NOTED ON PLANS OR IN SPECIFICATIONS 2. PROVIDE HANGERS AND SEISMIC BRACING PER SMACNA AND BUILDING CODE REQUIREMENTS 3. LOCATE MANUAL BALANCING DAMPERS IMMEDIATELY DOWNSTREAM OF EACH DUCT TAP 4. CUSHION HEADS OR BILL HEAD TEES ARE NOT ALLOWED 5. MAINTAIN MINIMUM 36" CLEARANCE BETWEEN LEADING OR TRAILING ELBOW JOINT AND DUCT TAP FITTINGS 6. RADIUSED ELBOWS OR TURNING VANES REQUIRED ON RECTANGULAR DUCT SYSTEM ELBOWS SINGLE THICKNESS VANES UP TO 25" HEIGHT AND DOUBLE THICKNESS VANES IN DUCTS GREATER THAN 25" HEIGHT ‘-:Y SUPPLY DUCT FITTINGS 12=10 1" 1. DUCT 2. SHEET -METAL STRAP 1" (25.4 -MM) WIDE OF SAME METAL GAUGE AS DUCT. 3. ANGLE - NOT LESS THAN 1 "x1 "x1 /8" (25.4x25.4x3MM), SIZED TO MATCH DUCT. 4. SHEET -METAL BAND 1" (25.4 -MM) WIDE OF SAME METAL GAUGE AS DUCT. 5. ALL -THREAD HANGER ROD WITH ACCESSORIES AS USED FOR LIGHT PIPE HANGER. O SHEET METAL DUCT HANGERS 12" =110" SEAL AROUND ALL OPENINGS WITH SILICONE SEALANT. COLOR TO MATCH BUILDING SECURE REFRIGERANT PIPING TO SUPPORTS WITH MECHANICAL PIPE CLAMP OR EQUAL RUN INSULATION OF SUCTION LINE THRU CLAMP ASSEMBLY MECHANICAL STEEL CHANNEL OR EQUAL WELD BOTH SIDES (TYPICAL) 3" x 3" x 1/4" ANGLE ANCHORED TO STRUCTURE WITH TWO 3/8" x 3" EXPANSION BOLTS OR TWO LARGE LAG BOLTS I <7/ ///////////0 ^ y " " NOTES: 1. REFER TO PLANS FOR SIZES AND CONTINUATION REFRIGERANT PIPE WALL SUPPORT 12" = 1'-0" SIZE OF DUCT DROP TO MATCH NECK SIZE OF GRILLE (TYP) USE 45 DEGREE THROAT AT TAP 16 GAUGE GALVANIZED SLEEVE REFRIGERANT TUBING INSULATION WALL CENTERLINE RADIUS EQUALS 1.5 TIMES WIDTH. NO TURNING VANES REQUIRED UNLESS OTHERWISE NOTED VD VD MIN 36" BEFORE AND AFTER ELBOW VD AIRFLOW RADIUSED WYE BRANCHES. ALTERNATE SQUARE ELBOWS WITH TURNING VANES ALLOWABLE WHERE DUCT VELOCITIES ARE LESS THAN 1500 FPM 15 DEGREE TYP 30 DEGREE MAX PROVIDE REDUCER UPSTREAM OF BRANCH INLET CONICAL OR LO -LOSS 45 DEGREE FITTING PROVIDE REDUCER AT CONNECTION TO GRILLE WHERE BRANCH DUCT IS OVERSIZED NOTES: 1. PROVIDE DUCT LINER AND/OR EXTERNAL DUCT INSULATION AS NOTED ON PLANS OR IN SPECIFICATIONS 2. PROVIDE HANGERS AND SEISMIC BRACING PER SMACNA AND BUILDING CODE REQUIREMENTS 3. LOCATE MANUAL BALANCING DAMPERS IMMEDIATELY DOWNSTREAM OF EACH DUCT TAP 4. MAINTAIN MINIMUM 36" CLEARANCE BETWEEN LEADING OR TRAILING ELBOW JOINT AND DUCT TAP FITTINGS 5. TURNING VANES REQUIRED ON RECTANGULAR DUCT SYSTEM ELBOWS. SINGLE THICKNESS VANES UP TO 25" HEIGHT AND DOUBLE THICKNESS VANES IN DUCTS GREATER THAN 25" HEIGHT RADIUSED ELBOWS MAY BE USED AS AN ALTERNATE 6. NO TURNING VANES REQUIRED ON DUCT SIZES LESS THAN 180 SQ IN IF DUCT VELOCITY IS LESS THAN 1500 FPM ® RETURN EXHAUST DUCT FITTINGS 12=10 rncijirg LLER ARCHITECTURE INTERIORS PLANNING 275 FIFTH STREET, SUITE 100 BREMERTON, WA 98337 360-377-8773 RFMARCH.COM VIZLAB ECOTOPE PROJECT # 2017036 PERMIT SET ISSUE DATE REVISION SCHEDULE 8/30/2018 REVIEWED FOR CODE COMPLIAN APPROVED D NOV 062018 • CHANICAL- TAILS City of Tukwila BUILDING DIVISION RECEMO CIT`! OF T U WILA OCT 30 2018 PERMIT CENTER SHEET # M2.00 MECHANICAL SYSTEMS COMMISSIONING NOTES 1. IN ACCORDANCE WITH THE 2015 WASHINGTON STATE ENERGY CODE (WSEC) SECTION C408 BUILDING COMMISSIONING SHALL BE COMPLETED FOR MECHANICAL SYSTEMS* (C403), SERVICE WATER HEATING SYSTEMS (C404), CONTROLLED RECEPTACLES AND LIGHTING SYSTEMS (C405), ENERGY METERING (C409), AND REFRIGERATION (0410). a. *EXCEPTION (0408.2) MECHANICAL SYSTEMS ARE EXEMPT FROM COMMISSIONING PROCESS WHERE THE BUILDING'S TOTAL MECHANICAL EQUIPMENT CAPACITY IS LESS THAN 240,000 BTU/H COOLING CAPACITY AND LESS THAN 300,000 BTU/H HEATING CAPACITY b. CONTRACTORS ARE REQUIRED TO PERFORM PRE -FUNCTIONAL PERFORMANCE TESTING OF ALL EQUIPMENT PRIOR TO FUNCTIONAL PERFORMANCE TESTING BY THE COMMISSIONING AGENT (C408.2.3). CONTRACTORS SHALL PROVIDE THE NECESSARY ASSISTANCE TO THE COMMISSIONING AGENT TO PERFORM COMMISSIONING DUTIES. CONTRACTORS SHALL BE RESPONSIBLE FOR TAKING CORRECTIVE ACTION IF ANY DEFICIENCIES ARE FOUND DURING COMMISSIONING. 2. THE BUILDING COMMISSIONING PROCESS DELIVERABLES ARE AS FOLLOWS: a. COMMISSIONING PLAN (C408.1.2) SHALL BE DEVELOPED BY THE PROJECT'S CERTIFIED COMMISSIONING PROFESSIONAL AND INCLUDED WITH THE CONSTRUCTION DOCUMENTS b. TESTING AND BALANCING (C408.2.2) ALL HVAC SYSTEMS SHALL BE BALANCED BYA LICENSED CONTRACTOR IN ACCORDANCE WITH GENERALLY ACCEPTED ENGINEERING STANDARDS AND SPECIFICATIONS PRIOR TO COMMISSIONING. c. FINAL COMMISSIONING REPORT (0408.1.3) A FINAL COMMISSIONING REPORT SHALL BE COMPLETED AND CERTIFIED BY THE CERTIFIED COMMISSIONING PROFESSIONAL AND DELIVERED TO THE BUILDING OWNER OR OWNER'S AUTHORIZED AGENT. 3. BUILDING DOCUMENTATION AND CLOSE OUT SUBMITTAL REQUIREMENTS (C103.6) OWNER TRAINING BY CONTRACTORS FOR EACH PIECE OF EQUIPMENT OR SYSTEM SHALL INCLUDE: a. SYSTEM/EQUIPMENT OVERVIEW (WHAT IT IS, WHAT IT DOES, AND WHICH OTHER SYSTEMS OR EQUIPMENT DOES IT INTERFACE WITH). b. REVIEW OF AVAILABLE O&M MATERIALS. REVIEW OF THE RECORD DRAWINGS ON THE SUBJECT SYSTEM/EQUIPMENT. c. HANDS-ON DEMONSTRATION OF ALL NORMAL MAINTENANCE PROCEDURES, NORMAL OPERATING MODES, AND ALL EMERGENCY SHUTDOWN AND START-UP PROCEDURES. GENERAL NOTES 1. THESE PLANS ARE SCHEMATIC AND DO NOT SHOW EXACT ROUTING OR EVERY OFFSET WHICH MAY BE REQUIRED. THE HVAC CONTRACTOR IS TO COORDINATE WITH ALL OTHER TRADES AND IS TO VERIFY ALL CLEARANCES BEFORE COMMENCING WORK. 2. MATERIALS, METHODS, AND INSTALLATION SHALL COMPLY WITH THE PROVISIONS OF THE LATEST EDITION OF THE WASHINGTON STATE ENERGY CODE (WSEC), INTERNATIONAL MECHANICAL CODE (IMC) WITH WASHINGTON STATE AMENDMENTS, INTERNATIONAL BUILDING CODE (IBC) WITH WASHINGTON STATE AMENDMENTS, INTERNATIONAL FIRE CODE (IFC) AND OTHER APPLICABLE STATE AND LOCAL CODES AND ORDINANCES. 3. DUCT CONSTRUCTION AND HANGINGS SHALL COMPLY WITH THE LATEST IMC AND WITH CURRENT SMACNA STANDARDS. 4. JOINTS OF DUCT SYSTEM SHALL BE SEALED WITH DUCT MASTIC. 5. DUCTS SHALL BE INSULATED AS INDICATED ON PLANS TO MEET THE REQUIREMENTS OF CURRENT CODES AND SPECIFICATIONS. 6. FLEXIBLE DUCTS SHALL ONLY BE USED WHERE SHOWN AND SHALL NOT EXCEED 6 FT IN LENGTH UNLESS NOTED OTHERWISE. 7. PROVIDE EARTHQUAKE RESTRAINT FOR HVAC EQUIPMENT IN ACCORDANCE WITH THE CURRENT IBC. 8. PIPING PENETRATIONS OF FIRE RATED WALLS OR FLOOR SHALL BE SLEEVED AND FIRE STOPPED WITH LISTED MATERIALS SO AS TO MAINTAIN THE INTEGRITY AND RATING OF THE FLOOR OR WALL. 9. HVAC EQUIPMENT, VALVES, AND DAMPERS SHALL BE LOCATED IN EASILY ACCESSIBLE LOCATIONS, UNLESS SHOWN ON ARCHITECTURAL DRAWINGS. REQUIRED ACCESS PANELS SHALL BE PROVIDED BY THE HVAC CONTRACTOR AND INSTALLED BY THE GENERAL CONTRACTOR. 10. SEE ARCHITECTURAL DRAWINGS FOR LOCATION OF EXPOSED DUCTWORK AND GRILLES. 11. ALL DUCT DIMENSIONS INDICATE FREE AREA. SOUND LINING AND EXTERIOR INSULATION ARE LABELED AS SUCH. ENERGY CODE GENERAL NOTES 1. SEE MECHANICAL AND PLUMBING SCHEDULES FOR EQUIPMENT TYPE, CAPACITY AND EFFICIENCY. 2. PROVIDE THERMOSTAT CONTROLS CAPABLE OF A FIVE (5) DEGREE DEADBAND BETWEEN HEATING AND COOLING. 3. PROVIDE AUTOMATIC SETBACK CONTROLS WITH NIGHT SETBACK AND SEVEN (7) DIFFERENT DAY TYPES. 4. PROVIDE DAMPERS FOR OUTSIDE AIR INTAKES AND EXHAUST FANS WHICH CLOSE AUTOMATICALLY WHEN THE SYSTEM IS OFF, EXCEPT FOR THOSE SYSTEMS WHICH OPERATE CONTINUOUSLY WITH LESS THAN 20 CFM/SF LEAKAGE FOR BAROMETRIC DAMPERS, AND LESS THAN 10 CFM/SF LEAKAGE FOR MOTORIZED DAMPERS. 5. PROVIDE MICROPROCESSOR -BASED THERMOSTAT FOR HEAT PUMP CONTROLS. 6. PROVIDE A MEANS OF BALANCING EVERY AIR SUPPLY OUTLET AND AIR OR WATER TERMINAL DEVICE. 7. SIMULTANEOUS HEATING AND COOLING IN A ZONE IS NOT PERMITTED. 8. SEAL TRANSVERSE SEAMS OF ALL DUCTWORK. 9. SEALING TO CONTROL BUILDING ENVELOPE AIR LEAKAGE AND AIR TIGHTNESS TESTING IS REQUIRED PER 2015 SEC SECTIONS 0402.5.1 THROUGH C402.5.8. 10. DUCTWORK AND PLENUMS SHALL BE THERMALLY INSULATED IN ACCORDANCE WITH 2015 SEC SECTION C403.2.8. 11. ALL PIPING SHALL BE THERMALLY INSULATED TO MEET SPECIFICATIONS SET IN PIPE INSULATION TABLE ON SHEET P0.01 PLUMBING SCHEDULE AND GENERAL NOTES. 12. ALL ELECTRIC MOTORS GREATER THAN 1.0 HP SHALL MEET THE REQUIREMENTS OF 2015 SEC SECTION C403.2.14. 13. WATER HEATING EQUIPMENT AND STORAGE TANKS SHALL MEET THE MINIMUM REQUIREMENTS OF TABLE C404.2 OF THE 2015 SEC. MECHANICAL LEGEND SYMBOL DESCRIPTION IHP-1 SIZE 1 FLOW 48"x10 r., rens 111111111111111 El (CO2 SECTION/ELEVATION VIEW DETAIL VIEW EQUIPMENT TAG SHEET NOTE TAG REVISION TAG DIFFUSER/GRILLE TAGE RECTANGULAR FREE AREA DUCT DIMENSIONS (8" WIDTH x 10" DEPTH) ROUND DUCT FREE AREA DIMENSIONS (6" DIAMETER) FLEX DUCT AIR DIRECTION SUPPLY DUCT IN/OUT OF PAGE EXHAUST/RETURN DUCT IN/OUT OF PAGE THERMOSTAT CO2 SENSOR DESCRIPTION ENVELOPE PENETRATION PUMP SUPPLY/EXHAUST FAN PRESSURE GAGE TEMPERATURE GAGE TURNING VANES MECHANICAL ABBREVIATIONS AFF ARCH BLDG BMS BTUH CD CLG CTE CW CWR CWS DCVA DDC DHW DIA DN E ELEV EWT FC FCO FLR FP GC GEO GPM GWB HTG HW HWR HWS INV LAV MECH NFA OHP POC PLUM PSI REF RF RPBP TYP UV VTR WC WCO WHF ABOVE FINISHED FLOOR ARCHITECT BUILDING BUILDING MANAGEMENT SYSTEM BRITISH THERMAL UNITS PER HOUR CONDENSATE COOLING CONNECT TO EXISTING COLD WATER CHILLED WATER RETURN CHILLED WATER SUPPLY DOUBLE CHECK VALVE ASSEMBLY DIRECT DIGITAL CONTROL DOMESTIC HOT WATER DIAMETER DOWN EXISTING ELEVATION ENTERING WATER TEMPERATURE FAN COIL FLOOR CLEANOUT FLOOR FIRE PROTECTION GENERAL CONTRACTOR GEOTHERMAL GALLONS PER MINUTE GYPSUM WALLBOARD HEATING HOT WATER HOT WATER RETURN HOT WATER SUPPLY INVERT LAVATORY MECHANICAL NET FREE AREA OUTDOOR HEATPUMP POINT OF CONNECTION PLUMBING POUNDS PER SQUARE INCH REFER/REFERENCE RELIEF FAN REDUCED PRESSURE BACKFLOW PREVENTER TYPICAL UNIT VENTILATORS VENT THRU ROOF WATER CLOSET WALL CLEAN OUT WHOLE HOUSE FAN INDOOR HEAT PUMPS TAG 00 -INFO -LOCATION MANUFACTURER MODEL UNIT TYPE OUTDOOR UNIT COOLING CAPACITY HEATING CAPACITY DIMENSIONS WEIGHT ELECTRICAL NOTES HEIGHT WIDTH DEPTH VOLTS/PHASE MCA IHP-1 OPEN OFFICE 200 MITSUBISHI PLFY-P12NCMU-E CEILING CASSETTE OHP -1 12,000 Btu/h 13,500 Btu/h 0' - 10 5/8" 2' - 1 5/8" 2' - 1 5/8" 37 Ib 208VAC/ 1PH 0.35 1 IHP-2 OPEN OFFICE 200 MITSUBISHI PLFY-P12NCMU-E CEILING CASSETTE OHP -1 12,000 Btu/h 13,500 Btu/h 0' - 10 5/8" 2' - 1 5/8" 2' - 1 5/8" 37 Ib 208VAC/ 1PH 0.35 1 IHP-3 OPEN OFFICE 200 MITSUBISHI PLFY-P12NCMU-E CEILING CASSETTE OHP -1 12,000 Btu/h 13,500 Btu/h 0' - 10 5/8" 2' - 1 5/8" 2' - 1 5/8" 37 Ib 208VAC/ 1PH 0.35 1 IHP-4 OFFICE 204 MITSUBISHI PKFY-P06NBMU-E2 WALL CASSETTE OHP -2 6,000 Btu/h 6,700 Btu/h 0' - 11 5/8" 2' - 8 3/16" 0' - 8 3/16" 22 Ib 208VAC/ 1 PH 0.19 1 IHP-5 OFFICE 205 MITSUBISHI PKFY-P06NBMU-E2 WALL CASSETTE OHP -1 6,000 Btu/h 6,700 Btu/h 0' - 11 5/8" 2' - 8 3/16" 0' - 8 3/16" 22 Ib 208VAC/ 1 PH 0.19 1 IHP-6 OFFICE 206 MITSUBISHI PKFY-P06NBMU-E2 WALL CASSETTE OHP -1 6,000 Btu/h 6,700 Btu/h 0' - 11 5/8" 2' - 8 3/16" 0' - 8 3/16" 22 Ib 208VAC/ 1PH 0.19 1 IHP-7 OFFICE 209 MITSUBISHI PLFY-P08NCMU-ER4 CEILING CASSETTE OHP -1 8,000 Btu/h 9,000 Btu/h 0' - 10 5/8" 2' - 1 5/8" 2' - 1 5/8" 34 Ib 208VAC/ 1PH 0.29 1 IHP-8 OFFICE 210 MITSUBISHI PLFY-P08NCMU-ER4 CEILING CASSETTE OHP -1 8,000 Btu/h 9,000 Btu/h 0' - 10 5/8" 2' - 1 5/8" 2' - 1 5/8" 34 Ib 208VAC/ 1 PH 0.29 1 IHP-9 CONFERENCE 203 MITSUBISHI PLFY-P08NCMU-ER4 CEILING CASSETTE OHP -1 8,000 Btu/h 9,000 Btu/h 0' - 10 5/8" 2' - 1 5/8" 2' - 1 5/8" 34 Ib 208VAC/ 1 PH 0.29 1 1. PROVIDE HEAT PUMP WITH INTEGRAL CONDENSATE PUMP GOBI II OR EQUIVALENT (20 dBA © 3FT). CONTRACTOR SHALL COORDINATE CONDENSATE PIPING ROUTING TO NEAREST APPROVED DRAIN LOCATION. 2. IHPS TO BE CONTROLLED BY SIMPLE MA CONTROLLER (PAC-YT53CRAU) OR OTHER APPROVED THERMOSTAT. OPEN OFFICE (IHP1, IHP2, IHP3) SINGLE ZONE TO BE CONTROLLED BY ONE THERMOSTAT LOCATED PER SHEET M1.00. OUTDOOR HEAT PUMPS TAG LOCATION/SERVICE MANUFACTURER MODEL COOLING CAPACITY HEATING CAPACITY COP ©47F EER WEIGHT ELECTRICAL NOTES VOLTS/PHASE MCA OHP -1 ROOF/TI SPACE MITSUBISHI PURY-P72TLMU-A(-BS) 72,000 Btu/h 80,000 Btu/h 4.30 14.8 444 Ib 208, 3-PHASE, 60HZ 24 1, 2, 3, 4 1. COORDINATE ROOF LOCATION PER STRUCTURAL. 2. INSTALL VRF OUTDOOR UNIT ON FLASHED SLEEPERS ON EXISTING ROOF. INSTALL PER DETAIL 4 ON SHEET M2.00 3. ALL REFRIGERANT PIPING INSULATION TO BE 1" THICK WALL WITH VAPOR BARRIER (PDM) OR EQUIVALENT. 4. DEFROST INTEGRAL TO VRF. BC CONTROLLERS TAG SERVICE MANUFACTURER MODEL VOLTS/PHASE CURRENT DRAW (AMPS) WEIGHT (LBS) NOTES BC -1 OHP -1 MITSUBISHI CMB-P108NU-G1 208V/1 PHASE 0.68 84 1, 2 1. PROVIDE ACCESSORY CONDENSATE PUMP FOR CONDENSATE MANAGEMENT AND ROUTE CONDENSATE TO APPROVED LOCATION PER 2015 UPC 2. CAP ADDITIONAL PORTS FOR FUTURE USE ENERGY RECOVERY VENTILATORS TAG MANUFACTURER MODEL FLOW ENTHALPY RECOVERY EFFICIENCY TEMPERATURE RECOVERY EFFICIENCY WEIGHT VOLTS/PHASE 04-ELEC-MCA NOTES ERV -1 LOSSNAY LGH-F470RX5-E 470 CFM 64% 69% 119.00 Ib 208V / 1PH 3.1 1,2 1. PROVIDE VENTILATION CONTROLLER AND CO2 SENSOR IN RETURN DUCT FOR CONTROL OF UNIT FAN (SEE MI.00 FOR APPROXIMATE LOCATION). SEE CONTROL SPEC FOR SEQUENCE OF OPERATION. 2. OUTSIDE AIR DAMPERS TO BE ENERGIZED OPEN WHEN UNIT IS ON AND CLOSE WHEN UNIT IS SHUT OFF. DIFFUSERS, LOUVERS, & GRILLES TAG MANUFACTURER MODEL TYPE FINISH SIZE R1 SHOEMAKER 830 PERFORATE 4 -WAY T -BAR CEILING RETURN GRILLE SEE ARCH 24" x 24" R2 SHOEMAKER 915 AIRFOIL WALL RETURN GRILLE SEE ARCH SEE PLANS 51 SHOEMAKER 700 MA 4 -WAY T -BAR CEILING SUPPLY DIFFUSER SEE ARCH 24"x24" S2 SHOEMAKER 903 AIRFOIL DOUBLE DEFLECTION SUPPLY GRILLE SEE ARCH SEE PLANS VENTILATION RATES SPACE AREA (SF) OCCUPANCY (# PEOPLE) EXHAUST RATE PEOPLE OUTDOOR AIR SUPPLY RATE Rp (CFM/PERSON) AREA OUTDOOR AIR SUPPLY RATE Ra (CFM/SF) MIN VENTILATION (CFM) ACTUAL VENTILATION (CFM) OPEN OFFICE 200 2191 12 SF = 5 0.06 195 200 CONFERENCE 203 275 14 SF = 5 0.06 90 90 OFFICE 204 114 1 190 SF = 5 0.06 15 15 OFFICE 205 111 1 SF = 5 0.06 15 15 OFFICE 206 111 1 SF = 5 0.06 15 15 COPY ROOM 207 114 0 1 CFM/SF 0 0 115 EXHAUST 1" AIR GAP UNDER DOOR, 115 EXHAUST OFFICE 209 178 1 D. Wall Insulation, above and below grade (OPAQUE area only, does not include window & door area) 5 0.06 20 20 OFFICE 210 181 1 SF = 5 0.06 20 20 WEATHERIZATION 211 (STORAGE) 153 NA SF = 0 0.12 20 20 MAINTENANCE 212 (STORAGE) 103 NA 0 0.12 15 15 CORRIDOR 472 12 Btuh 0 0.12 60 60 BASIS OF DESIGN PROJECT SCOPE: CONVERT HEATED STORAGE TO OFFICE SPACE. PROJECT WILL ADD HIGH EFFICIENCY VARIABLE REFRIGERANT FLOW (VRF) HEAT PUMP SYSTEM AND ENERGY RECOVERY VENTILATION SYSTEM. SEE SEQUENCE OF OPERATIONS SPEC FOR DETAILS. BELOW ARE KEY DETAILS. 1. INTEGRATE WITH EXISTING SYSTEM: A. VRF SYSTEM - INTEGRATE NEW VRF WITH EXISTING BUILDING VRF SYSTEM CONTROL B. DOAS - CONTROL ERV DOAS SYSTEM USING EXISTING VRF CONTROLS (GB -50) 2. ERV CONTROL: ERV TO BE POWERED ON/OFF BY EXISTING VRF SYSTEM. FAN MODULATION CONTROLLED WITH CO2 SENSOR LOCATED PER M1.00 IN ERV RETURN DUCT. 3. CEILING FANS - CEILING FANS LOCATED IN OPEN OFFICE SPACE. SEE ELECTRICAL SCHEDULE 4. EXISTING STRUCTURE AND SYSTEMS: A. DEMO PLAN - SEE M0.02 FOR MODIFICATIONS TO EXISTING SYSTEMS. CONTRACTORS TO FIELD VERIFY EXISTING STRUCTURE AND SYSTEMS AND TAKE APPROPRIATE ACTION TO AVOID OR MODIFY AS NEEDED. Department of Planning and Development SEATTLE ENERGY CODE Instructions: See reverse REVISIONS No chanaes shalt bp. made to tho stoop of work without prior approve, of Tu'.wrila Building Division. f OTE: rlsva;,iCns will require a new plan submittal and may include additional plan review fees, FILE COPY Permit Nos Lon?, _7 Plan review approval is subject to errors and omissions. Approval of construction documents doss not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and conditions is acknowledged: Date: /2_ [� City of Tukwila BUILDING DIVISION Project Address: 700 ADOVER PARK WEST TUKWILA, WA 98188 Date of this submittal 2/23/2018 Project Number. Permit Number. HEATING EQPM`r SIZING - OPEN OFFICE January2011 Building Component Description Including U -Factor or F -Factor Heat Loss Factor (HLF = U x 46°At) (1) Component Square Feet (SF) Linear Feet (LF) Cubic Feet (CF) (2) Component Heat Loss (HLF x SF, LF or CF) A. Window, Glass Block Sliding & Swinging Glass Door Skylight Garden Window Single, uncertified (U = 1.20 ) Double, uncertified (U = 0.92 ) NFRC certified (U = 0.32 ) NFRC certified (U = 0.30 ) Skylight, single, uncertified (U = 1.58 ) Skylight, double, uncertified (U = 1.05 ) Skylight, NFRC certified (U = 0.50 ) Garden window, single, uncertified (U = 2.60 ) Garden window, double, uncertified (U = 1.81 ) Other _STOREFRONT (U = 0.38 ) 55.2 /SF x 42.3 /SF x 14.7 /SF x 13.8 /SF x 72.7 /SF x 48.3 /SF x 23.0 /SF x 119.6 /SF x 83.3 /SF x 17.5 /SF x /SF x SF = Btuh SF = Btuh SF = Btuh 96 SF = 1325 Btuh SF = Btuh SF = Btuh SF = Btuh SF = Btuh SF =�33� Btuh 2 i Btuh 190 SF = Other (U = ) SF = Btuh B. Opaque Door Wood, in wood frame, uncertified (U = 0.46 ) Foam ins., in metal frame, uncertified (U = 0.37 ) Foam ins., in wood frame, uncertified (U = 0.16 ) Opaque door, NFRC certified (U= 0.20 ) Other (U = ) 21.2 /SF x 17.0 /SF x 7.4 /SF x 9.2 /SF x /SF x SF = Btuh SF = Btuh SF = Btuh SF = Btuh SF = Btuh C. Roof/Ceiling Insulation (OPAQUE area only, does not include skylight area) None (U = 0.400) R-38 (U = 0.031 ) R-49 standard or R-38 full depth (U= 0.027) R-60 (U = 0.025 ) R-38+12.5ci (U = 0.019) 18.4 /SF x 1.4 /SF x 1.2 /SF x 1.2 /SF x 0.9 /SF x SF = Btuh SF = Btuh 3260 SF = 4049 Btuh SF = Btuh SF = Btuh D. Wall Insulation, above and below grade (OPAQUE area only, does not include window & door area) None (U= 0.250) R-13, wood studs (U = 0.082) R-19, wood studs (U = 0.062) R-21 cavity + R-10 headers, wood (U = 0.051 ) R-19 cavity + R-5 cont., wood studs (U = 0.046 ) R-11, metal studs (U = 0.132) R-19, metal studs (U = 0.109 ) R-19 cavity + R-8.5 cont., metal stu (U = 0.057) R-13 cavity + R-10 cont., metal studs (U = 0.055) R-_5+12.5ci_ (U = 0.045) 11.5 /SF x 3.8 /SF x 2.9 /SF x 2.3 /SF x 2.1 /SF x 6.1 /SF x 5.0 /SF x 2.6 /SF x 2.5 /SF x 2.1 /SF x SF= Btuh SF = Btuh SF = Btuh SF = Btuh SF = Btuh SF = Btuh SF = Btuh SF = Btuh SF = 1558 SF = Btuh 3225 Btuh E. Floor Over Unheated Space None (U = 0.134) R-19 (U = 0.041 ) R-30 (U = 0.029) R-38 (U = 0.025) R-38 Floor over exposed (U = 0.034) 6.2 /SF x 1.9 /SF x 1.3 /SF x 1.2 /SF x 1.6 /SF x SF = Btuh SF = Btuh SF = Btuh SF = SF = Btuh Btuh F. Slab On Grade Floor Perimeter Insulation (use linear ft, NOT sq.ft) None (F = 0.730) R-10 (F = 0.540 ) R-_ (F = ) 33.6 /LF x 24.8 /LF x /IF x 112 LF = 3761 Btuh LF = Btuh LF = Btuh G. Basement Floor (for heated space ONLY) None (F = 0.460 ) R-_ (F = ) 21.2 /LF x /LF x LF = Btuh LF = Btuh H. Infiltration (use cubic ft, NOT sq.ft) Pre -1980 (.018 x 1.2 ACH) 1980-2010 (.018 x 0.6 ACH) Post -2010 (.018 x 0.35 ACH) 1.0 /CF x 0.5 ICF x 0.3 /CF x CF = Btuh 45640 CF = 22820 Btuh CF = Btuh (4) DHUSF: DHL divided by( = (Typical values for DHL/SF '` 2400 Heated floor area in SF) (3) Total Btuh/SF or 4.7 Watts/SF = Design Heating Load (DHL) in Btuh = If electric, divide by 3.413 for DHL in watts = 38501 Btuh 16 11281 Watts for new construction are 8 Bru/✓SF or 2.5 Watts/SF.) (5) Space Heating Equipment Sizing Minimum required size = DHL x 1.0 = Maximum allowed size = DHL x 1.5 = Limits (6) Proposed Space Heating Equipment 38501 Btuh or 11281 Watts Manufacturer. Model #. 57751 Btuh or 16921 Watts Heating output ' Btuh Efficiency AFUE Watts HSPF . PROJECT HVAC EQUIPMENT SIZED FOR COOLING LOAD I SEPARATE E PERMIT REQUIRED ED FOR: 0 Mechanical EI'Etectrical f Plumbing tik6as City of Tukwila 61,1l1DMIG DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED APR 11 2018 A -Tit - Ci fi,T of Tukwila ` BUILDING DIVISION RECEIVED CITY OF TUKWILA MAR 3 0 2018 PERMIT CENTER jORRECT1 LTR# ocerg LLER ARCHITECTURE INTERIORS PLANNING VIZLAB 275 FIFTH STREET, SUITE 100 BREMERTON, WA 98337 360-377-8773 RFMARCH.COM ECDTDPE c)00❑uop�o o0 ,), wa R'��°o 444 I oo,°�, 0 'Fc/sTER�77 ��`-000 <)‹b SIONAL ENop �o 0❑❑❑o 3, 2&, 20til z 0 >zig Q O O 1== w Ct aLiu Wco CD 0 <CD co g_� QUw� EL>In u_Z p�~ 0 Nft- O z (29 V p (13 Z � o 0 ti PROJECT # 2017036 PERMIT SET ISSUE DATE 3/28/2018 REVISION SCHEDULE GENERAL NOTES AND MECHANICAL SCHEDULE SHEET # M 0 .01 MAINTENANCE STORAGE .EATHE•► Q � ��r►a�4 lot Nr- Nr- 41.. ♦ 1 r 1 L J 1 0 SHEET NOTES 1 REMOVE AND SALVAGE EXISTING DUCTWORK AND DIFFUSER, MOVE TO NEW LOCATION. SEE SHEET M1.00 FOR NEW CONNECTION PLACEMENT. 2 MOVE EXISTING DUCTWORK OUTSIDE OF ENCLOSED STORAGE AREAS. SEE SHEET M1.00 FOR NEW DUCT PLACEMENT. CONFERENCE \-203 1 I.za LI! H1 F1 REVIEWED FOR CODE COMPLIANCE APPROVED APR 11 2018 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAR 3 0 2013 PERMIT CENTER RICP'i?rg ILLER ARCHITECTURE INTERIORS PLANNING VIZLAB 275 FIFTH STREET, SUITE 100 BREMERTON, WA 98337 360-377-8773 RFMARCH.COM ECOTDPE °OpOu❑0 NT Oe C , WASy�'G:\ °O z. ❑ O 77 GISTERFc) FS o o0o\ ONA0❑L�oo�o ° 3, 2t t ' z 0 >=E < O� rimnsw aW zQ ==== co o-) = U LLHLi_ O O z 0 __I V p Z � o ti PROJECT # 2017036 PERMIT SET ISSUE DATE REVISION SCHEDULE 3/28/2018 MECHANICAL- DEMO PLAN SHEET # M0.02 WEATH ERIZATION IL 2117 6"x4" S2 20 CFM \ \ \ (12� GENERAL NOTES A B REFRIGERANT PIPING SHALL BE INSULATED WITH MINIMUM 1" THICK WALL PIPING INSULATION, INCLUDING WHERE SUPPORTED ON ROOF. CONDENSATE DRAINS FROM INDOOR UNITS SHALL BE ROUTED TO SINGLE LOCATION. PROVIDE CONDENSATE PUMP WHERE NECESSARY. COORDINATE WITH MECHANICAL CONTRACTOR. C COORDINATE ALL NEW DUCTWORK INSTALLATION WITH EXISTING DUCTWORK AND EQUIPMENT IN AREAS OF WORK S1 24"x24"A 100 CFM -4— r L J 1 24"x24"'� 100 CFM - -4—I 1 BC CONTROLLER REFRIGERANT PIPING L6"x4"- 15 CFM T/. 10"o 30"x12" R 30"x12" 82670 CFM 11 662) "111 1 1 UV% 30"x12" I I Im �---r�+► 24"x24" -S1 135 CFM 30"x12" 82670 CFM 6 0 SHEET NOTES 1 INSTALL RECEPTACLE FOR CONDENSATE PUMP ABOVE T -BAR. ROUTE CONDENSATE TO EXISTING WALL OPEN SITE DRAIN IN EAST OFFICE DIVIDER WALL. 2 ELECTRICAL TO PROVIDE RECEPTABLE FOR SUMP PUMP FOR BC CONTROLLER 3 10' MIN SEPARATION BETWEEN SUPPLY AND EXHAUST LOUVERS 4 4 -WAY THROW DIFFUSER 5 ROUTE BC REFRIGERANT PIPING & POWER THROUGH EXISTING ROOF PENETRATION 6 ERV LOUVER 1SF MIN NFA. PROVIDE MECHANICAL DAMPER 7 SERVICE ACCESS AREA 8 1" UNDERCUT DOOR FOR RETURN AIR 9 CONTRACTOR TO FIELD VERIFY LOCATION OF SPRINKLER HEADS IN THIS AREA. MODIFY SPRINKLER PIPING AND SPRINKLER HEAD LOCATIONS AS NEEDED TO ENSURE SPRINKLER HEAD OPERATION IS NOT AFFECTED BY NEW EQUIPMENT OR DUCTWORK. 10 TRANSFER DUCTWORK TO ALLOW AIRFLOW TO EXISTING IHPS. INSTALL ON WALL ABOVE ACT -1 CEILING. INSTALL WIRE MESH SCREEN ON OPEN END OF TRANSFER DUCTWORK 11 INSTALL CO2 SENSOR IN ERV RETURN DUCTWORK DOWNSTREAM OF ALL BRANCH CONNECTIONS. 12 EXISTING DUCTWORK AND SUPPLY AIR DIFFUSERS TO BE MOVED OUTSIDE OF ENCLOSED AREAS AS NEEDED. SEE DEMO PLAN SHEET M0.02. 13 ADD BALANCING DAMPERS AT ALL BRANCHES (TYP) Fi REVIEWED FOR CODE COMPLIANCE APPROVED APR 11 2018 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAR 3 0 2018 PERMIT CENTER Rlcijirg ILLER ARCHITECTURE INTERIORS PLANNING VIZLAB 275 FIFTH STREET, SUITE 100 BREMERTON, WA 98337 360-377-8773 RFMARCH.COM E C DTO PE z 0 >laQ O 4 zz aw zQ CO co 0 >am lumm 0 oZ 0 02 co O ti F-- c� w ao oo ct Y � ct W Oo� Q�0 ti PROJECT # 2017036 PERMIT SET ISSUE DATE REVISION SCHEDULE 3/28/2018 MECHANICAL - TI FLOORPLAN SHEET # M1000 7 !r r \\\\ \'\ ` \\ ` \�' ' 0 SHEET NOTES 1 ROUTE REFRIGERANT AND POWER THROUGH EXISTING ROOF PENETRATION. ADD WEATHER HOOD COVER, SEAL TIGHTLY 2 COORDINATE FINAL PLACEMENT OF OUTDOOR UNIT WITH STRUCTURAL ENGINEER SERVICE ACCESS AREA E H1 REVIEWED FOR CODE COMPLIANCE APPROVED APR 11 2018 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAR 3 0 2018 PERMIT CENTER icerg LLER ARCHITECTURE INTERIORS PLANNING VIZLAB 275 FIFTH STREET, SUITE 100 BREMERTON, WA 98337 360-377-8773 RFMARCH.COM ECOTOPE R 0 0 C) Sys �� O opo o o z /STE?' • &OOo • °o oS/ONAL E�op000 o❑❑❑D 3,2g, 2-O z 0 >=3 Q 0Cs> 1==iw Ct aW cDO Q .7) 5- O w z0 0-z �e J Z ti PROJECT # 2017036 PERMIT SET ISSUE DATE 3/28/2018 REVISION SCHEDULE MECHANICAL - ROOF PLAN SHEET # M1.O1 MOUNT TO SIP PANEL ROOF ACCORDING TO SIP MANUFACTURER'S INSTRUCTIONS 11111111 emu ROOF, SEE ARCH FOR DETAILS NEOPRENE VIBRATION ISOLATORS, SIZED FOR 1/2" TOTAL STATIC DEFLECTION 1/2" THREADED ROD, TYPICAL HVAC UNIT NOTES: LOCK NUT, TYPICAL 1. EQUIPMENT MOUNTING AND CONNECTION AND SEISMIC RESTRAINTS TO BE DESIGNED AND STAMPED BY LICENSED WASHINGTON STATE ENGINEER AS A DEFERRED SUBMITTAL VIBRATION ISOLATION 012=10 SIDE VIEW GENERAL NOTE: U SHEET METAL HOOD WATER PROOF, SEE ARCH SPECS FOR WATER -PROOFING REQUIREMENTS FOAM IN OPENING AFTER REFRIGERANT PIPING IS INSTALLED ROOF OPENING REFRIGERANT PIPING TO OUTDOOR UNIT (TYP) 7---'‘V. REFRIGERANT PIPING TO BC CONTROLLER (TYP) SEE ARCH DRAWINGS FOR WEATHER -PROOFING DETAILS PRE -FABRICATED ROOF CURB NOTES: 1. REFRIGERANT PIPES TO BE INDIVIDUALLY INSULATED (1"). 2. MECHANICAL CONTRACTOR SHALL COORDINATE SLEEVES AND PENETRATIONS WITH GENERAL CONTRACTOR 3. SEE STRUCTURAL DRAWINGS FOR PENETRATION SEPARATION AND LOCATION REQUIREMENTS. REFRIGERANT PIPING ROOF ® PENETRATION 12" = 1'-0" U FETAL DECK 1r ROOF LEVEL }OSTSBELOW (TYP) FRONT VIEW INSULATION LAVER 1. PROVIDE VRF OUTDOOR UNIT BASE DESIGN AS A DEFERRED SUBMITTAL. DESIGN SHALL BE STAMPED BYA LICENSED WASHINGTON STATE STRUCTURAL ENGINEER. NUMBER NOTES: 1. PROVIDE STRUCTURAL INTERSTITIAL ANGLE IRON MOUNTING MEMBER OR SIMILAR ATTACHED DIRECTLY TO BOTTOM OF UNIT MOUNTING FLANGE AND PROVIDE CROSS BRACING FOR RIGIDITY. ENSURE IT CARRIES FULL MOUNTING FOOT WIDTH ON UNIT. FINAL SPECIFICATION OF MEMBER BY STRUCTURAL ENGINEER OF RECORD. 2. PROVIDE BRAIDED COPPER FLEXIBLE CONNECTOR, R410A RATED, 650PSI MAX WORKING PRESSURE, PACKLESS INDUSTRIES OR EQUAL ON ALL MAIN PIPING DOWNSTREAM OF TWINNING KITS/CONVERGING FITTINGS PRIOR TO PENETRATION THROUGH ROOF. 3. PIPE ROOF CURB, FLASHED AND SEALED WATER TIGHT, PROVIDE FLEXIBLE WATER TIGHT COLLAR TO ALLOW FOR MOVEMENT WHERE PIPE ENTERS CURB. DO NOT ENTER PIPE CURB FROM VERTICAL DIRECTION. COORDINATE OPENING WITH GENERAL CONTRACTOR. 4. TYPICAL BASE SUPPORT POSTS, SECURELY ANCHORED TO BUILDING STRUCTURE BELOW, QUANTITY, SIZE, AND CARRYING CAPACITY DETERMINED BY STRUCTURAL ENGINEER OF RECORD. 5. STRUCTURAL ANGLE IRON BASE MOUNTING FRAME WITH CROSS MEMBERS FOR RIGIDITY - FINAL SIZING BY STRUCTURAL ENGINEER OF RECORD. 6. VIBRATION SPRING SLR TYPE ISOLATORS (MASON INDUSTRIES OR EQUIV.) WITH RUBBER BASE PADS, SECURELY FASTENED TO STRUCTURAL BASE AND TO VRF UNIT INTERSTITIAL SUPPORT STEEL. SPRING ISOLATOR TO PROVIDE MINIMUM 1" DEFLECTION OR 10 TIMES THE STATIC DEFLECTION OF THE ROOF DECK FROM EQUIPMENT WEIGHT - DETERMINED BY STRUCTURAL ENGINEER OF RECORD. AT A MINIMUM, PROVIDE SPRING ISOLATORS AT EACH EQUIPMENT BASE MOUNTING HOLE LOCATION. 7. IF REQUIRED, ONLY SUPPORT LATERAL PIPE EMANATING FROM VRF UNIT CONNECTIONS BY CROSS MEMBER SUPPORT THAT IS ATTACHED DIRECTLY TO VRF UNIT MOUNTING ANGLE IRON FRAME ABOVE SPRING ISOLATORS. DO NOT ATTACH ANY PIPING TO LOWER FIXED SUPPORT BASE. 8. USE NEOPRENE ISOLATION COLLARS ON PIPE CLAMS WHEN FASTENING PIPING TO SUPPORTS. 9. USE LONG RADIUS SWEEPING COPPER ACR TUBE PIPE BENDS WHERE PIPE ENTERS BUILDING AT FIRST ELBOW INTO CEILING SPACE TO MINIMIZE REFRIGERANT FLOW NOISE AND VIBRATION. 10. ALL ELECTRICAL CONNECTIONS TO UNITS TO BE VIA FLEXIBLE CONDUIT, PROVIDE SUFFICIENT SLACK TO ALLOW FOR UNIT MOVEMENT ON SPRING ISOLATORS. 11. ENSURE CROSS MEMBERS OF INTERSTITIAL FRAME AND BOTTOM SUPPORT FRAME ARE NOT DIRECTLY BELOW ENDS OF MODULES IN ALL LOCATIONS. AND DO NOT BLOCK DRAINAGE WEEP HOLES IN BOTTOM OF UNIT CASING, FAILURE TO DO THIS MAY RESULT IN ICE DAMMING/BUILDUP BENEATH UNIT AND SUBSEQUENT BUILDUP OF ICE IN BOTTOM OF UNIT CASING BELOW COIL AND POTENTIAL DAMAGE TO BOTTOM OF COIL. 12. WHEN SELECTING SPRING ISOLATORS ALWAYS CONSIDER WEIGHT DISTRIBUTION BY REFERENCING EQUIPMENT WEIGHT AND CENTER OF GRAVITY. NEAR RIGHT ENDS OF UNITS (VIEWED FROM FRONT PANEL) SPRING WEIGHT CAPACITY MAY BE LARGER. IF HIGHER SPRING WEIGHT CAPACITY IS REQUIRED VS OTHER SPRING LOCATIONS, CONSIDER AN ADDITIONAL SPRING OF EQUAL "K" VALUE (lbs/in) NEAR RIGHT END OF LAST MODULE. IN GENERAL IT IS RECOMMENDED TO SELECT ALL MOUNTING SPRINGS OF EQUIVALENT "K" VALUE (lbs/in). ® VRF OUTDOOR UNIT MOUNTING DETAIL 12=10 CONICAL OR LO - LOSS 45 DEGREE BOOT FITTING WITH VOLUME DAMPER ROUND NECK DIFFUSER (TYP) ROUND SHEET - METAL DUCT WALL HUNG INDOOR UNIT INDOOR UNIT DISCONNECT SHALL BE RECESSED IN WALL, SUBMIT DISCONNECT TO ECOTOPE FOR REVIEW MOUNT UNIT TO WALL WITH MANUFACTURER'S BRACKET, ALL PIPING AND ELECTRICAL CONNECTIONS SHALL BE MADE BEHIND THE UNIT IN THE INTERIOR WALL. UNIT SHALL SIT FLUSH ON THE WALL INTERIOR FRAMED WALL NOTES: 1. PROVIDE WITH CONDENSATE PUMP IF NECESSARY. ® TYPICAL WALL HUNG UNIT DETAIL 12=10 VD FLEXIBLE DUCT 7' MAX LENGTH W/ ONE 90 DEGREE BEND SQUARE TO ROUND TRANSITION VDD 45 DEGREE LO -LOSS BOOT TAP OR CONICAL TAP REDUCER TO MATCH DIFFUSER NECK SIZE IF BRANCH DUCT IS OVERSIZED. LOCATE AT CONNECTION TO DIFFUSER SPLITTER DAMPER WHERE SHOWN. DO NOT USE ON VAV SYSTEMS VD TRANSITION 15 DEGREE TYPICAL, 30 DEGREE MAXIMUM TYPICAL SQUARE NECK DIFFUSER SIZE OF DUCT DROP TO MATCH DIFFUSER NECK SIZE MIN 36" BEFORE AND AFTER ELBOW CENTERLINE RADIUS EQUALS 1.5 TIMES WIDTH AIRFLOW VD VD VD i II NOTES: 1. PROVIDE DUCT LINER AND/OR EXTERNAL DUCT INSULATION AS NOTED ON PLANS OR IN SPECIFICATIONS 2. PROVIDE HANGERS AND SEISMIC BRACING PER SMACNA AND BUILDING CODE REQUIREMENTS 3. LOCATE MANUAL BALANCING DAMPERS IMMEDIATELY DOWNSTREAM OF EACH DUCT TAP 4. CUSHION HEADS OR BILL HEAD TEES ARE NOT ALLOWED 5. MAINTAIN MINIMUM 36" CLEARANCE BETWEEN LEADING OR TRAILING ELBOW JOINT AND DUCT TAP FITTINGS 6. RADIUSED ELBOWS OR TURNING VANES REQUIRED ON RECTANGULAR DUCT SYSTEM ELBOWS SINGLE THICKNESS VANES UP TO 25" HEIGHT AND DOUBLE THICKNESS VANES IN DUCTS GREATER THAN 25" HEIGHT © SUPPLY DUCT FITTINGS 12" = 1'-0" 1.1 1. DUCT 2. SHEET -METAL STRAP 1" (25.4 -MM) WIDE OF SAME METAL GAUGE AS DUCT. 3. ANGLE - NOT LESS THAN 1 "x1 "x1 /8" (25.4x25.4x3MM), SIZED TO MATCH DUCT. 4. SHEET -METAL BAND 1" (25.4 -MM) WIDE OF SAME METAL GAUGE AS DUCT. 5. ALL -THREAD HANGER ROD WITH ACCESSORIES AS USED FOR LIGHT PIPE HANGER. SHEET METAL DUCT HANGERS 0 12" = SEAL AROUND ALL OPENINGS WITH SILICONE SEALANT. COLOR TO MATCH BUILDING SECURE REFRIGERANT PIPING TO SUPPORTS WITH MECHANICAL PIPE CLAMP OR EQUAL RUN INSULATION OF SUCTION LINE THRU CLAMP ASSEMBLY 16 GAUGE GALVANIZED SLEEVE REFRIGERANT TUBING MECHANICAL STEEL' CHANNEL OR EQUAL WELD BOTH SIDES (TYPICAL) 3" x 3" x 1/4" ANGLE ANCHORED TO STRUCTURE WITH TWO 3/8" x 3" EXPANSION BOLTS OR TWO LARGE LAG BOLTS NOTES: 1. REFER TO PLANS FOR SIZES AND CONTINUATION ® REFRIGERANT PIPE WALL SUPPORT 12" = 1'-0" SIZE OF DUCT DROP TO MATCH NECK SIZE OF GRILLE (TYP) USE 45 DEGREE THROAT AT TAP AIRFLOW RADIUSED WYE BRANCHES. ALTERNATE SQUARE ELBOWS WITH TURNING VANES ALLOWABLE WHERE DUCT VELOCITIES ARE LESS THAN 1500 FPM VD [�_ VD CENTERLINE RADIUS EQUALS 1.5 TIMES WIDTH. NO TURNING VANES REQUIRED UNLESS OTHERWISE NOTED MIN 36" BEFORE AND AFTER ELBOW VD 15 DEGREE TYP 30 DEGREE MAX PROVIDE REDUCER UPSTREAM OF BRANCH INLET CONICAL OR LO -LOSS 45 DEGREE FITTING PROVIDE REDUCER AT CONNECTION TO GRILLE WHERE BRANCH DUCT IS OVERSIZED NOTES: 1. PROVIDE DUCT LINER AND/OR EXTERNAL DUCT INSULATION AS NOTED ON PLANS OR IN SPECIFICATIONS 2. PROVIDE HANGERS AND SEISMIC BRACING PER SMACNA AND BUILDING CODE REQUIREMENTS 3. LOCATE MANUAL BALANCING DAMPERS IMMEDIATELY DOWNSTREAM OF EACH DUCT TAI' REVIEWED FOR 4. MAINTAIN MINIMUM 36" CLEARANCE BETWEEN LEADING OR TRAILING ELBOW JOINT AND CODE COMPLIANCEbUCT TAP FITTINGS APPROVED 5. TURNING VANES REQUIRED ON RECTANGULAR DUCT SYSTEM ELBOWS. SINGLE THICKNRSS VANES UP TO 25" HEIGHT AND DOUBLE THICKNESS VANES IN DUCTS GREATER THAN 25" HEIGHT RADIUSED ELBOWS MAY BE USED AS AN ALTERNATE 6. NO TURNING VANES REQUIRED ON DUCT SIZES LESS THAN 180 SQ IN IF DUCT VELOCITY IS LESS THAN 1500 FPM ® RETURN EXHAUST DUCT FITTINGS 12" = 11-0" APR 112018 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAR 3 0 2018 PERMIT CENTER icerg LLER ARCHITECTURE INTERIORS PLANNING VIZLAB 275 FIFTH STREET, SUITE 100 BREMERTON, WA 98337 360-377-8773 RFMARCH.COM ECOTOPE o°° PWT I O0�oo -/,<><> C)0, Gjv ASy� p o e� o /STE9F' (c` --e 000 SSiONAL E000 0 oo❑oa 3,2e',Z)t ' >a= imam= Q C7 Ft) O>sza icy= z 0 v PROJECT # 2017036 PERMIT SET ISSUE DATE 3/28/2018 REVISION SCHEDULE MECHANICAL - DETAILS SHEET # M2.00 f0 _I .1- )0 ID LI °C III _IIL IIID - FETAL DECK 1r ROOF LEVEL }OSTSBELOW (TYP) FRONT VIEW INSULATION LAVER 1. PROVIDE VRF OUTDOOR UNIT BASE DESIGN AS A DEFERRED SUBMITTAL. DESIGN SHALL BE STAMPED BYA LICENSED WASHINGTON STATE STRUCTURAL ENGINEER. NUMBER NOTES: 1. PROVIDE STRUCTURAL INTERSTITIAL ANGLE IRON MOUNTING MEMBER OR SIMILAR ATTACHED DIRECTLY TO BOTTOM OF UNIT MOUNTING FLANGE AND PROVIDE CROSS BRACING FOR RIGIDITY. ENSURE IT CARRIES FULL MOUNTING FOOT WIDTH ON UNIT. FINAL SPECIFICATION OF MEMBER BY STRUCTURAL ENGINEER OF RECORD. 2. PROVIDE BRAIDED COPPER FLEXIBLE CONNECTOR, R410A RATED, 650PSI MAX WORKING PRESSURE, PACKLESS INDUSTRIES OR EQUAL ON ALL MAIN PIPING DOWNSTREAM OF TWINNING KITS/CONVERGING FITTINGS PRIOR TO PENETRATION THROUGH ROOF. 3. PIPE ROOF CURB, FLASHED AND SEALED WATER TIGHT, PROVIDE FLEXIBLE WATER TIGHT COLLAR TO ALLOW FOR MOVEMENT WHERE PIPE ENTERS CURB. DO NOT ENTER PIPE CURB FROM VERTICAL DIRECTION. COORDINATE OPENING WITH GENERAL CONTRACTOR. 4. TYPICAL BASE SUPPORT POSTS, SECURELY ANCHORED TO BUILDING STRUCTURE BELOW, QUANTITY, SIZE, AND CARRYING CAPACITY DETERMINED BY STRUCTURAL ENGINEER OF RECORD. 5. STRUCTURAL ANGLE IRON BASE MOUNTING FRAME WITH CROSS MEMBERS FOR RIGIDITY - FINAL SIZING BY STRUCTURAL ENGINEER OF RECORD. 6. VIBRATION SPRING SLR TYPE ISOLATORS (MASON INDUSTRIES OR EQUIV.) WITH RUBBER BASE PADS, SECURELY FASTENED TO STRUCTURAL BASE AND TO VRF UNIT INTERSTITIAL SUPPORT STEEL. SPRING ISOLATOR TO PROVIDE MINIMUM 1" DEFLECTION OR 10 TIMES THE STATIC DEFLECTION OF THE ROOF DECK FROM EQUIPMENT WEIGHT - DETERMINED BY STRUCTURAL ENGINEER OF RECORD. AT A MINIMUM, PROVIDE SPRING ISOLATORS AT EACH EQUIPMENT BASE MOUNTING HOLE LOCATION. 7. IF REQUIRED, ONLY SUPPORT LATERAL PIPE EMANATING FROM VRF UNIT CONNECTIONS BY CROSS MEMBER SUPPORT THAT IS ATTACHED DIRECTLY TO VRF UNIT MOUNTING ANGLE IRON FRAME ABOVE SPRING ISOLATORS. DO NOT ATTACH ANY PIPING TO LOWER FIXED SUPPORT BASE. 8. USE NEOPRENE ISOLATION COLLARS ON PIPE CLAMS WHEN FASTENING PIPING TO SUPPORTS. 9. USE LONG RADIUS SWEEPING COPPER ACR TUBE PIPE BENDS WHERE PIPE ENTERS BUILDING AT FIRST ELBOW INTO CEILING SPACE TO MINIMIZE REFRIGERANT FLOW NOISE AND VIBRATION. 10. ALL ELECTRICAL CONNECTIONS TO UNITS TO BE VIA FLEXIBLE CONDUIT, PROVIDE SUFFICIENT SLACK TO ALLOW FOR UNIT MOVEMENT ON SPRING ISOLATORS. 11. ENSURE CROSS MEMBERS OF INTERSTITIAL FRAME AND BOTTOM SUPPORT FRAME ARE NOT DIRECTLY BELOW ENDS OF MODULES IN ALL LOCATIONS. AND DO NOT BLOCK DRAINAGE WEEP HOLES IN BOTTOM OF UNIT CASING, FAILURE TO DO THIS MAY RESULT IN ICE DAMMING/BUILDUP BENEATH UNIT AND SUBSEQUENT BUILDUP OF ICE IN BOTTOM OF UNIT CASING BELOW COIL AND POTENTIAL DAMAGE TO BOTTOM OF COIL. 12. WHEN SELECTING SPRING ISOLATORS ALWAYS CONSIDER WEIGHT DISTRIBUTION BY REFERENCING EQUIPMENT WEIGHT AND CENTER OF GRAVITY. NEAR RIGHT ENDS OF UNITS (VIEWED FROM FRONT PANEL) SPRING WEIGHT CAPACITY MAY BE LARGER. IF HIGHER SPRING WEIGHT CAPACITY IS REQUIRED VS OTHER SPRING LOCATIONS, CONSIDER AN ADDITIONAL SPRING OF EQUAL "K" VALUE (lbs/in) NEAR RIGHT END OF LAST MODULE. IN GENERAL IT IS RECOMMENDED TO SELECT ALL MOUNTING SPRINGS OF EQUIVALENT "K" VALUE (lbs/in). ® VRF OUTDOOR UNIT MOUNTING DETAIL 12=10 CONICAL OR LO - LOSS 45 DEGREE BOOT FITTING WITH VOLUME DAMPER ROUND NECK DIFFUSER (TYP) ROUND SHEET - METAL DUCT WALL HUNG INDOOR UNIT INDOOR UNIT DISCONNECT SHALL BE RECESSED IN WALL, SUBMIT DISCONNECT TO ECOTOPE FOR REVIEW MOUNT UNIT TO WALL WITH MANUFACTURER'S BRACKET, ALL PIPING AND ELECTRICAL CONNECTIONS SHALL BE MADE BEHIND THE UNIT IN THE INTERIOR WALL. UNIT SHALL SIT FLUSH ON THE WALL INTERIOR FRAMED WALL NOTES: 1. PROVIDE WITH CONDENSATE PUMP IF NECESSARY. ® TYPICAL WALL HUNG UNIT DETAIL 12=10 VD FLEXIBLE DUCT 7' MAX LENGTH W/ ONE 90 DEGREE BEND SQUARE TO ROUND TRANSITION VDD 45 DEGREE LO -LOSS BOOT TAP OR CONICAL TAP REDUCER TO MATCH DIFFUSER NECK SIZE IF BRANCH DUCT IS OVERSIZED. LOCATE AT CONNECTION TO DIFFUSER SPLITTER DAMPER WHERE SHOWN. DO NOT USE ON VAV SYSTEMS VD TRANSITION 15 DEGREE TYPICAL, 30 DEGREE MAXIMUM TYPICAL SQUARE NECK DIFFUSER SIZE OF DUCT DROP TO MATCH DIFFUSER NECK SIZE MIN 36" BEFORE AND AFTER ELBOW CENTERLINE RADIUS EQUALS 1.5 TIMES WIDTH AIRFLOW VD VD VD i II NOTES: 1. PROVIDE DUCT LINER AND/OR EXTERNAL DUCT INSULATION AS NOTED ON PLANS OR IN SPECIFICATIONS 2. PROVIDE HANGERS AND SEISMIC BRACING PER SMACNA AND BUILDING CODE REQUIREMENTS 3. LOCATE MANUAL BALANCING DAMPERS IMMEDIATELY DOWNSTREAM OF EACH DUCT TAP 4. CUSHION HEADS OR BILL HEAD TEES ARE NOT ALLOWED 5. MAINTAIN MINIMUM 36" CLEARANCE BETWEEN LEADING OR TRAILING ELBOW JOINT AND DUCT TAP FITTINGS 6. RADIUSED ELBOWS OR TURNING VANES REQUIRED ON RECTANGULAR DUCT SYSTEM ELBOWS SINGLE THICKNESS VANES UP TO 25" HEIGHT AND DOUBLE THICKNESS VANES IN DUCTS GREATER THAN 25" HEIGHT © SUPPLY DUCT FITTINGS 12" = 1'-0" 1.1 1. DUCT 2. SHEET -METAL STRAP 1" (25.4 -MM) WIDE OF SAME METAL GAUGE AS DUCT. 3. ANGLE - NOT LESS THAN 1 "x1 "x1 /8" (25.4x25.4x3MM), SIZED TO MATCH DUCT. 4. SHEET -METAL BAND 1" (25.4 -MM) WIDE OF SAME METAL GAUGE AS DUCT. 5. ALL -THREAD HANGER ROD WITH ACCESSORIES AS USED FOR LIGHT PIPE HANGER. SHEET METAL DUCT HANGERS 0 12" = SEAL AROUND ALL OPENINGS WITH SILICONE SEALANT. COLOR TO MATCH BUILDING SECURE REFRIGERANT PIPING TO SUPPORTS WITH MECHANICAL PIPE CLAMP OR EQUAL RUN INSULATION OF SUCTION LINE THRU CLAMP ASSEMBLY 16 GAUGE GALVANIZED SLEEVE REFRIGERANT TUBING MECHANICAL STEEL' CHANNEL OR EQUAL WELD BOTH SIDES (TYPICAL) 3" x 3" x 1/4" ANGLE ANCHORED TO STRUCTURE WITH TWO 3/8" x 3" EXPANSION BOLTS OR TWO LARGE LAG BOLTS NOTES: 1. REFER TO PLANS FOR SIZES AND CONTINUATION ® REFRIGERANT PIPE WALL SUPPORT 12" = 1'-0" SIZE OF DUCT DROP TO MATCH NECK SIZE OF GRILLE (TYP) USE 45 DEGREE THROAT AT TAP AIRFLOW RADIUSED WYE BRANCHES. ALTERNATE SQUARE ELBOWS WITH TURNING VANES ALLOWABLE WHERE DUCT VELOCITIES ARE LESS THAN 1500 FPM VD [�_ VD CENTERLINE RADIUS EQUALS 1.5 TIMES WIDTH. NO TURNING VANES REQUIRED UNLESS OTHERWISE NOTED MIN 36" BEFORE AND AFTER ELBOW VD 15 DEGREE TYP 30 DEGREE MAX PROVIDE REDUCER UPSTREAM OF BRANCH INLET CONICAL OR LO -LOSS 45 DEGREE FITTING PROVIDE REDUCER AT CONNECTION TO GRILLE WHERE BRANCH DUCT IS OVERSIZED NOTES: 1. PROVIDE DUCT LINER AND/OR EXTERNAL DUCT INSULATION AS NOTED ON PLANS OR IN SPECIFICATIONS 2. PROVIDE HANGERS AND SEISMIC BRACING PER SMACNA AND BUILDING CODE REQUIREMENTS 3. LOCATE MANUAL BALANCING DAMPERS IMMEDIATELY DOWNSTREAM OF EACH DUCT TAI' REVIEWED FOR 4. MAINTAIN MINIMUM 36" CLEARANCE BETWEEN LEADING OR TRAILING ELBOW JOINT AND CODE COMPLIANCEbUCT TAP FITTINGS APPROVED 5. TURNING VANES REQUIRED ON RECTANGULAR DUCT SYSTEM ELBOWS. SINGLE THICKNRSS VANES UP TO 25" HEIGHT AND DOUBLE THICKNESS VANES IN DUCTS GREATER THAN 25" HEIGHT RADIUSED ELBOWS MAY BE USED AS AN ALTERNATE 6. NO TURNING VANES REQUIRED ON DUCT SIZES LESS THAN 180 SQ IN IF DUCT VELOCITY IS LESS THAN 1500 FPM ® RETURN EXHAUST DUCT FITTINGS 12" = 11-0" APR 112018 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAR 3 0 2018 PERMIT CENTER icerg LLER ARCHITECTURE INTERIORS PLANNING VIZLAB 275 FIFTH STREET, SUITE 100 BREMERTON, WA 98337 360-377-8773 RFMARCH.COM ECOTOPE o°° PWT I O0�oo -/,<><> C)0, Gjv ASy� p o e� o /STE9F' (c` --e 000 SSiONAL E000 0 oo❑oa 3,2e',Z)t ' >a= imam= Q C7 Ft) O>sza icy= z 0 v PROJECT # 2017036 PERMIT SET ISSUE DATE 3/28/2018 REVISION SCHEDULE MECHANICAL - DETAILS SHEET # M2.00