Loading...
HomeMy WebLinkAboutPermit M18-0045 - NW ACCESSORIES - HEAT PUMP REPLACEMENTNW ACCESSORIES 17616 WEST VALLEY HWY EXPIRED 10/30/18 MI 8-0045 Parcel No: Address: 0 City of Tukwila 0 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 2523049017 Permit Number: 17616 WEST VALLEY HWY Project Name: NW ACCESSORIES Issue Date: Permit Expires On: M18-0045 4/16/2018 10/13/2018 Owner: Name: Address: Contact Person: Name: TERRENO 17600 WVH LLC 101 MONTGOMERY ST #200 , SAN FRANCISCO, WA, 94104 JESSE CHUTICH Address: 3202 C ST NE , AUBURN, WA, 98002 Contractor: Name: COMFORT MECHANICAL INC (CONSTRUCT) Address: 3202 C ST NE , AUBURN, WA, 98002 License No: COMFOM1015LA Lender: Name: Address: Phone: (425) 251-9840 Phone: (425) 251-9840 Expiration Date: 4/25/2018 DESCRIPTION OF WORK: REPLACE (1) 10 TON PACKAGED HEAT PUMP WITH NEW SAME CAPCITY UNIT Valuation of Work: $11,008.00 Type of Work: REPLACEMENT Fuel type: ELECT Fees Collected: $368.13 Electrical Service Provided by: PUGET SOUND ENERGY Water District: RENTON Sewer District: RENTON Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Date: 141 it,i I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. �' Signature: ' Date: Y 6 4 g Print Name: S 5 ( /c-1 71: G4-' This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: Readily accessible access to roof mounted equipment is required. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the: building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: ***MECHANICAL PERMIT CONDITIONS*** 10: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 11: Manufacturers installation instructions shall be available on the job site at the time of inspection. 12: The attached set of mechanical plans have been reviewed by The Tukwila Fire Marshals Office and are acceptable with the following concerns: 13: H.V.A.C. units rated at greater than 2,000 cfm require auto -shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2437) 14: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air -moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 15: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2437) 0 16: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2437) 17: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 18: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 19: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 20: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 21: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1400 FIRE FINAL 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL 0702 SMOKE DETECTOR TEST c c CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No Project No. Date Application Accepted:;( Date Application Expires: (For office use 1y) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address: 17 61 % W Vq 1 t 'Y 1I w y Tenant Name: f V 1n/ AcceSSor eS King Co Assessor's Tax No.: 2 S2 3 o' - 41017 Suite Number: Floor: Raaf' New Tenant: ❑ Yes ...No PROPERTY OWNER Name: -rL' /'remo (-GC Address: / 76 OC w V411 City: 7ti k State: 1,1A Zip: 61 8 CONTACT PERSON - person receiving all project communication Name: Jesse Chutich Address: 3202 C St NE City: Auburn State: WA Zip: 98002 Phone: (425) 251-9840 Fax: Email: Jesse@comfoiluiech.com MECHANICAL CONTRACTOR INFORMATION ' , Company Name: Comfort Mechanical Inc. Address: 3202 C St NE City: Auburn State: WA Zip: 98002 Phone: (425) 251-9840 Fax: Contr Reg No.: COMFOMI015LA Exp Date: 04/25/2018 Tukwila Business License No.: BUS -0993365 Valuation of project (contractor's bid price): $ 1 1/ 00 D Describe the scope of work in detail: Rtriit'e C!) 10` P'tck.5eJ ie41' (1 i$47 W/ yieL' Sal, C pit4;�Fy (And'. Use: Residential: New ❑ Commercial: New Replacement Replacement Fuel Type: Electric ...W Gas ❑ iDgf. Other: H:Wpplications\Forms-Applications On Line\2016 Applications\Mechanical Permit Application Revised 1-0-16.docx Revised: January 2016 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Residential, Nighttime Furnace >100k btu r 1 Floor furnace 55 dB(A) Suspended/wall/floor mounted heater 57 dB(A) Appliance vent Commercial Repair or addition to heat/refrig/cooling system 47 dB(A) Air handling unit 65 dB(A) <10,000 cfin 60 dB(A) Unit Type Qty Air handling unit Residential, Nighttime >10,000 cfin Industrial Evaporator cooler 55 dB(A) Ventilation fan connected to single duct 57 dB(A) Ventilation system Commercial Hood and duct 47 dB(A) Incinerator — domestic 65 dB(A) Incinerator — comm/industrial 60 dB(A) Unit Type Qt Fire damper Residential, Nighttime Diffuser Industrial Thermostat 55 dB(A) Wood/gas stove 57 dB(A) Emergency generator Commercial Other mechanical equipment 47 dB(A) 60 dB(A) 65 dB(A) Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytim A few sounds are exempt from the noise code, including: • Warning devices; • Construction and property maintenance during the daytime hours (7am-lOpm); • Testing of backup generators during the day. PERMIT APPLICATION NOTES Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM,AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OW OR AUTHORIZED AGENT: Signature: Print Name: Jesse Chutich Mailing Address: 3202 C St NE H:\Applications\Portes-Applications On Line\2016 Applications\Mechanical Permit Application Revised I-4-16.docx Revised January 2016 bh Date: OA? Day Telephone: (425) 251-9840 Aburn . WA 98002 City State Zip Page 2 of 2 DESCRIPTIONS PermitTRAK I ACCOUNT QUANTITY • PAID $368.13 M18-0045 Address: 17616 WEST VALLEY HWY Apn: 2523049017 $368.13 Credit Card Fee $10.72 Credit Card Fee R000.369.908.00.00 0.00 $10.72 MECHANICAL $343.66 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $241.78 PLAN CHECK FEE R000.322.102.00.00 0.00 $68.73 TECHNOLOGY FEE $13.75 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R14156 R000.322.900.04.00 0.00 $13.75 $368.13 Date Paid: Wednesday, April 04, 2018 Paid By: JESSE CHUTICH Pay Method: CREDIT CARD 514072 Printed: Wednesday, April 04, 2018 1:27 PM 1 of 1 SYSTEMS INSPECTION RECORD Retain a copy with permit NO. INSPECTION NO. PERMIT CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 tii ops Pro' ct: r ios. •Type of In pection: r� ed ddrreess: WecCiVek4 �' /� a•mSpecial Instructions: %ate Wanted: _ �i 5 — 24/ jS p.m. Requester C Phone No e - % -3843 Approved per applicable codes. Corrections required prior to approval. COMMENTS: MLcilet t «i k u CAPPreve40 4c -Smolt -e. 11e (shat -ofF -Ts/ C---c-tg-/zie.: Mecil, /wed_ -----160,4P/41._ /re F .0/eel �► Ka-`nl i Qt)C T ra - Inspector: (11 n 11 Date: 5-3-2L'1 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. FLE REVIEWED FOR CODE COMPLIANCE APPROVED APR 12 2018 City of Tukwila BUILDING DIVISION .n 10.'4; •N, MIOEOO'1s STRUCTURAL CALCULATIONS Northwest Accessory RTU 17616 West Valley Highway Tukwila, Washington APRIIL 2, 2018 PREPARED FOR: Comfort Mechanical 3202 C Street NE Auburn, Washington 98002 PREPARED BY: Moore Engineering Group 21902 96th Avenue SE Snohomish, Washington Moore RECEIVED EngineerirTY OF TUKWILA Group APR 0 4 2018 PERMIT CENTER GENERAL STRUCTURAL NOTES: 1. ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THESE NOTES AND THE INTERNATIONAL BUILDING CODE (IBC), 2015 EDITION. 2. DESIGN LOADING CRITERIA: ROOF LIVE LOAD 25 PSF MECHANICAL UNIT 1,662 POUNDS EARTHQUAKE SDS = 0.906 SITE CLASS D to E WIND 110 MPH, EXPOSURE B 3. STRUCTURAL CALCULATIONS AND SKETCHES SHALL BE USED IN CONJUNCTION WITH MECHANICAL DRAWINGS FOR BIDDING AND CONSTRUCTION. CONTRACTOR SHALL VERIFY DIMENSIONS AND CONDITIONS FOR COMPATIBILITY AND SHALL NOTIFY ENGINEER OF ALL DISCREPANCIES PRIOR TO CONSTRUCTION. 4. THE EDGE BEAM SUPPORTING THE UNIT COULD NOT BE VERIFIED PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL CONFIRM THE EXISTING EDGE BEAM IS AT LEAST A 4x6 MEMBER. IF THE BEAM IS EITHER A 2x4 OR A 2x6, CONTRACTOR IS TO NAIL A 2x10 TO THE SIDE OF THE EXISTING 2x MEMBER WITH 10d NAILS x 3" AT 8" ON - CENTER, STAGGERED. CONNECT THE 2x10 TO THE TOP CHORD OF THE TRUSSES WITH AN A35 ANCHOR. 5. CONTRACTOR TO VERIFY ALL EXISTING DIMENSIONS, MEMBER SIZES AND CONDITIONS PRIOR TO COMMENCING ANY WORK. IF THE EXISTING CONDITIONS DO NOT CLOSELY MATCH THE CONDITIONS SHOWN ON THE SKETCHES, OR IF THE EXISTING MATERIALS ARE OF QUESTIONABLE OR SUBSTANDARD QUALITY, NOTIFY THE ENGINEER PRIOR TO COMMENCING ANY WORK. 6. CONTRACTOR SHALL PROVIDE TEMPORARY BRACING FOR THE STRUCTURE AND STRUCTURAL COMPONENTS UNTIL ALL FINAL CONNECTIONS HAVE BEEN COMPLETED IN ACCORDANCE WITH THE DRAWINGS. 7. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES REQUIRED FOR THE COMPLETION OF THE WORK. 8. FRAMING LUMBER SHALL BE KILN DRIED OR MC -19, AND GRADED AND MARKED IN CONFORMANCE WITH W.C.L.B. STANDARD GRADING RULES FOR WEST COAST LUMBER NO. 17. FURNISH TO THE FOLLOWING MINIMUM STANDARDS: JOISTS: (2x MEMBERS) HEM -FIR NO. 2 Fb = 850 PSI, Fv = 150 PSI 9. TIMBER CONNECTORS CALLED OUT BY LETTERS AND NUMBERS SHALL BE "STRONG - TIE" BY SIMPSON COMPANY, AS SPECIFIED IN THEIR CATALOG NO. C -C-2017. INSTALL NUMBER AND SIZE OF FASTENERS AS SPECIFIED BY MANUFACTURER. CONNECTORS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. 10. SHEET METAL SCREWS SHALL CONFORM TO THE AMERICAN IRON AND STEEL e-4 INSTITUTE (AISI) "SPECIFICATIONS FOR THE DESIGN OF COLD -FORMED STEEL 0 STRUCTURAL MEMBERS". "' 11. NAILS UTILIZED SHALL HAVE THE FOLLOWING MINIMUM PROPERTIES: NAIL 8d 10d 16d SHANK DIAMETER 0.131" 0.148' 0.148" HEAD DIAMETER 0.281" 0.312" 0.344" MINIMUM LENGTH 2-1/2" 3" 3-1/4" 12. CONNECT THE UNIT TO THE METAL CURB ADAPTER AND THE METAL CURB ADAPTER TO THE EXISTING METAL CURB WITH A MINIMUM OF (4) #12 SHEET METAL SCREWS ON EACH SIDE OF THE UNIT. PLACE ONE SCREW AT 6" TO 8" FROM EACH CORNER OF THE UNIT AND THE REAMINING SCREWS EQUIDISTANT BETWEEN ON EACH SIDE. PROJECT DESCRIPTION: The project consists of the replacement of an existing rooftop mechanical unit. LOADS: LIVE DEAD DEAD + LIVE WIND SEISMIC Roofing and re -roof 1/2" plywood sheathing 2x4 @ 24" on -center 4x14 @ 8' on -center Roof trusses at 8' on -center Insulation MEP Ceiling & Lights Total Dead 110 mph, Exposure B Latitude Longitude Site Class SDs (D) = SDs (E) = SDS EQUIPMENT Existing RTU -1 Unit 1,610 Existing Curb 200 Curb Adapter Total 1,810 pounds Dimensions 4.0 1.5 0.7 1.6 2.2 1.0 2.0 2.0 15 25 PSF 40 PSF 47.445 -122.244 DtoE WA DNR 0.953 0.858 0.906 New RTU -1 1,227 200 235 1,662 pounds 88"x59"x72" high Moore Engineering Group PROJECT: NORTHWEST ACCESSORY RTU ENGR: KWM DATE: 4/2/ 18 SCALE: 34, SHEET 3/29/2018 Design Maps Summary Report z, Design Maps Summary Report User -Specified Input Report Title Northwest Accessory RTU Thu March 29, 2018 19:07:47 UTC Building Code Reference Document 2012/2015 International Building Code (which utilizes USGS hazard data available in 2008) Site Coordinates 47.445°N, 122.244°W Site Soil Classification Site Class D - "Stiff Soil" Risk Category I/II/III USGS-Provided Output Ss = 1.429 g SI = 0.532 g SMs = 1.429 g SMI = 0.798 g SDs = 0.953 g SDI = 0.532 g For information on how the SS and Si values above have been calculated from probabilistic (risk -targeted) and deterministic ground motions in the direction of maximum horizontal response, please return to the application and select the "2009 NEHRP" building code reference document. 1 e.5 135 1.3, v'. 04.0 045 0.15 UJ *1 NICER Response Spectrum .v7 +.'+.3• ,.41 •)t) 0111-1 1..0 I. 1.4! 1.0, 12'J:' 2i.' Perid T Ism) Destrn Response Spectrum Although this information is a product of the U.S. Geological Survey, we provide no warranty, expressed or implied, as to the accuracy of the data contained therein. This tool is not a substitute for technical subject -matter knowledge. 4/4 https://earthquake.usgs.gov/cn 1 /designmaps/us/summary.php?template=minimal&latitude=47.445&longitude=-122.244&siteclass=3&riskcategory=0&edition=ibc-21 3/29/2018 Design Maps Summary Report mums Design Maps Summary Report User -Specified Input Report Title Northwest Accessory RTU Thu March 29, 2018 19:08:21 UTC Building Code Reference Document 2012/2015 International Building Code (which utilizes USGS hazard data available in 2008) Site Coordinates 47.445°N, 122.244°W Site Soil Classification Site Class E - "Soft Clay Soil" Risk Category I/II/III USGS-Provided Output Ss = 1.429 g Si = 0.532 g SMS = 1.287 g SMI = 1.277 g Sus = 0.858 g SDI = 0.852 g For information on how the SS and S1 values above have been calculated from probabilistic (risk -targeted) and deterministic ground motions in the direction of maximum horizontal response, please return to the application and select the "2009 NEHRP" building code reference document. RICER Response Spectrum Period, T ssee) v Design Response Spectrum °AO ,'.ia➢ r.�,di I,,X) 1 Pcriod, T tscc) Although this information is a product of the U.S. Geological Survey, we provide no warranty, expressed or implied, as to the accuracy of the data contained therein. This tool is not a substitute for technical subject -matter knowledge. 7'14 https://earthq uake.usgs.gov/cn 1 /designmaps/us/summary. php?template=minimal&latitude=47.445&long etude=-122.244&siteclass=4&riskcategory=0&edition=ibc-21 L9. cS) 0'0 ...42 Ls; •:-. , ... Ts < \--- Base unit < ` erasions 25%AIR/ECONOMIZER HOOD --6=iI 3" S` rDKO FPT DRAIN CONNECTION (80TH SIDES) II -01A DRAIN HOLE (BOTHSIDES) ALTERNATE RETURN AIR PANEL ELECTRICAL ENTRANCE 2s' REAR VIEW OUTDOOR AIR FANS 16 2.567* AIR /ECONOMIZER HOOD ��HEATER ACCESS UNIT CONTROL SOX ACCESS PANEL INDOOR COIL COMPRESSOR END OUTDOOR COIL n 2"K0 DK0 HOLE 2-6-x' ��• A 4�FPT DRAIN CONNECTION _s. DRAIN HOLE 5" IIS FRONT VIEW • • Accessory dimensions Nom 4-x 4- (3?) 004 TYP. 4 PLACES miTERED CORNERS (TOP ONLY) Rfc-%-.1 GASKET (SuPPLIED wrrn cues) DIMENSIONS (ft -in.) UNIT A SOPO012 & 016 B LC DESCRIPTION 1-0 (sr Standard (305) Curb 4 r REF. , 50PQ012 & 016 50P0.012 1"6-6- 1/8 &o16 ; (155) _ 1 2-0 Double Height i (610) Curb —t- 0-2-112 : 2-0 Side/Supply (64) i (610) and Return Curb NOTES: 1. Dimensions in parentheses ( ) are millimeters 2. Attach all ductwork to roofcurb 3. Insulated panels, 1" thick neoprene -coated, density. 2$7, VENT Am/ ECONOMIZER HOOD 1-1/2 lb OPYKKAL, 6LpDu 0 (SEE NoTE 2) ROOF CURB SECTION A -A RIGID INSULATION FELD suPPUED SW 1E0 iN BLOO(OFF PAN 2'- 'oft" AIR OUT SIDE SUPPLY cuRa (50P0900151) FIELD SUPPLIED TPANRITtegit ffl Tt Accessory dimensions (cont) ACCESSORY ZONE THERMOSTAT hysical dat 4. t 1� n 1-\'�. t AGCRY nacre. 99Krti0L PAt1EL ACCESSORY REMOTE CONTROL PACKAGE UNIT SIZE 60PQ OPERATING WT (Ib) Unit with Economizer Roof Curb __ COMPRESSOR ...Type Oil (oz) Capacity Steps 012 016 — REFRIGERANT REFRIGERANT (Capillary Control) Charge (Ib) Sys 1 Sys 2 OUTDOOR COIL Rows Fins/in. Total Face Area (sq ft) OUTDOOR AIR FAN Nominal Cfm No. —Diem (in.) Motor Hp (1100 Rpm)...Kw Input INDOOR COIL Total Face Area (sq ft) Rows...Fins/in. INDOOR BLOWER No. Wheels...Size (in.) Nominal Cfm Rpm Range Max Allowable Rpm Fan Pulley Pitch Diam (in.) Motor Pulley Pitch Diam (in.) Motor Hp (1750 Rpm) INDOOR AIR FILTERS, Type No. ...Size (in.) Std Alt Std Alt Std Alt Std Alt 1460 ` 1750 1610 \ 1900 I. 200 200 Full Hermetic, 2 Cyl Semi -Hermetic, 4 Cyl 2 .P64 2. 060818 76 ea 112 ea 100, 50, 0 100, 50, 0 R-22 R-22 78,78 168, 168 Copper Tube, Aluminum Plate Fins 2 3 17 14 189 222 Propeller Type, Direct Drive 8000 12,000 2 22 2 26 1/2 12 1 22 Copper Tube, Aluminum Plate Fins 165 165 2 17 3 14 Centrifugal, Adjustable Belt Drive 2 10x10 6000 916-1186 1158-1428 1550 6.4 64 3 4-4 4 4 3-5 3 3 3 2 10x10 4000 690- 978 878-1191 1550 55 5.5 2.4-3 4 2 8-3 8 1 1-1/2 10% efficient -- Disposable Fiber Glass 2 20x20x2 4 20x20x2 2 16x25x2 4 16x20x2 3 16x20x2 `System 1 consists of upper portion of outdoor coil and lower portion of indoor coil 'VENTILATION KUoOFF HON coSYSTEM mu al FAN off nUri1'- , 3 4 4- ❑ 1 ❑ 1 1 0 1 1 0 ❑ 1 1 DI 1 , t 1� n 1-\'�. t AGCRY nacre. 99Krti0L PAt1EL ACCESSORY REMOTE CONTROL PACKAGE UNIT SIZE 60PQ OPERATING WT (Ib) Unit with Economizer Roof Curb __ COMPRESSOR ...Type Oil (oz) Capacity Steps 012 016 — REFRIGERANT REFRIGERANT (Capillary Control) Charge (Ib) Sys 1 Sys 2 OUTDOOR COIL Rows Fins/in. Total Face Area (sq ft) OUTDOOR AIR FAN Nominal Cfm No. —Diem (in.) Motor Hp (1100 Rpm)...Kw Input INDOOR COIL Total Face Area (sq ft) Rows...Fins/in. INDOOR BLOWER No. Wheels...Size (in.) Nominal Cfm Rpm Range Max Allowable Rpm Fan Pulley Pitch Diam (in.) Motor Pulley Pitch Diam (in.) Motor Hp (1750 Rpm) INDOOR AIR FILTERS, Type No. ...Size (in.) Std Alt Std Alt Std Alt Std Alt 1460 ` 1750 1610 \ 1900 I. 200 200 Full Hermetic, 2 Cyl Semi -Hermetic, 4 Cyl 2 .P64 2. 060818 76 ea 112 ea 100, 50, 0 100, 50, 0 R-22 R-22 78,78 168, 168 Copper Tube, Aluminum Plate Fins 2 3 17 14 189 222 Propeller Type, Direct Drive 8000 12,000 2 22 2 26 1/2 12 1 22 Copper Tube, Aluminum Plate Fins 165 165 2 17 3 14 Centrifugal, Adjustable Belt Drive 2 10x10 6000 916-1186 1158-1428 1550 6.4 64 3 4-4 4 4 3-5 3 3 3 2 10x10 4000 690- 978 878-1191 1550 55 5.5 2.4-3 4 2 8-3 8 1 1-1/2 10% efficient -- Disposable Fiber Glass 2 20x20x2 4 20x20x2 2 16x25x2 4 16x20x2 3 16x20x2 `System 1 consists of upper portion of outdoor coil and lower portion of indoor coil Performance Summary For 1OT Pkg HP Project: NVBP Prepared By: 03/23/2018 10:33AM Part Number:50TCQD12A2A6-0A0G0 ARI EER:. 11.00 IEER_______._._____.._.___.__»._____.....__—. __.. _ ___ .__ _ __ ._ __ ....___—_ 12.5 Base Unit Dimensions UnitLength:___-.__-__.—_-_.__..._._________—..-_________.__—_..__________—__._.____. ___._--_—_.......88.1 in Unit Width' 59 5 in Unit Height 49.4 in Operating Weight Base Unit Weight. ___ _ __ _..____.__—__ .._.__..__—._ ____ _ _1050 Ib Medium Static Option Belt Drive:.__—.____...._........_..._—_____.......__.____—____.___._._._...___.___.___.—__15 Ib 2 -Speed Indoor Fan (VFD) ____20 Ib Accessories 15.2/16.5 kW 460/480-3-60, 11,5 kw 400-3-50 Volt Electric Heater:.. —_— _ ___.__— 45 Ib Single Point Kit:_ ._..12 Ib LOW LEAK - Vertical Economizer:_____._— _.._____ -75 1b Total Operating Weight: — _.__ __.---- _ __ _ .______—_ M..__. _ __ _. ..._._...._.._.1227 tb Unit Unit Voltage -Phase -Hertz:__..._-.._...___.— __...460-3-60 Air Discharge:-__—___.._.._.-___--__—__.-_.______._—__—_____________ __-.____.________-__Vertical Fan Drive Type: .... _____. _._.._-_-_. _ ---_._.____ _.____. _ _. ._Belt Actual Airflow:_4000 CFM Site Altitude' --.0 ft Cooling Performance Condenser Entering Air DB:._ .____—__ -- __._..._____._._ __._.._.__ _._____ _ ___ ___ ___.95.0 F Evaporator Entering Air DBv_._______.—_.._ ___..___. _--_ ___. --__._ ___ __ .__ 80.0 F Evaporator Entering Air WB:.._..________._._ -_._.____.___—_.T__._.__..__._._..._—__.._—________...___67.0 F Entering Air Enthalpy:.._ _____ ______.._ _ _____31.44 BTU/ib Evaporator Leaving Air DB: _ _ ___..__. ___ _ _ __ _ ____._ _ ___ _ _ __._59.6 F Evaporator Leaving Air W.B. 57.8 F Evaporator Leaving Air Enthalpy:. _ _ _ _— ___ ._.—._._ _..._____._ --____—__.___._...24.87 BTU/lb Gross Cooling Capacity:__________________________________—______ . _____.._.__118.20 MBH Gross Sensible Capacity:_. ___ __..____— _ _—._.______ ___._—__ ___-88.11 MBH Compressor Power Input- 10 84 kW Coil Bypass Factor:.._-.._—.__.____..._.-_______--____.________.-..____.----..--___________.0.084 Heating Performance Outdoor Ambient Temperature' 47 0 F Entering Air Indoor Coil DB- 70.0 F Leaving Air Indoor Coil DB' 96.8 F Total Heating Capacity 115.90 MBH Integrated Heating Capacity' 115.90 MBH Heating Power Input 11 27 kW High Temperature COP' 3.3 LowTemperature COP:—_._ ___.__....._.... _ __.___...__.___—.—._____..—_—_____._.__.__..-_ ------.2.3 Electric Heating Capacity:__.__—___._..____.__ __ __.—___. _ ___...._ _ —_-_-_ 15.20 kW Unit Leaving Air Temp:__---_ _.--- 108.8 F Supply Fan External Static Pressure:__. ____ 0.60 in wg Options / Accessories Static Pressure—^.--�, ^�—�_.—.__.�--.—�� Electric Heaters:_____-._...._.—.____._. _____________ _ _ __0.08 In wg Economizer 0 20 in wg Total Application Static (ESP + Unit Opts/Acc )• 879 in wg Fan RPM' Fan Power 2 08 BHP Packaged Rooftop Builder 1.49f Page 7 of 11 lb/lq Certified Drawing for 10T Pkg HP Es & 9 m•-• F. CC 0 CC 0 La 0 e Les La 0 M 4.1 \ §\ \ \ Packaged Rooftop Builder 1.49f "44 Certified Drawing for 10T Pkg HP fi $a Egg a�u 0 Em M N O 1- w a o 0 Packaged Rooftop Builder 1.49f 7-4 0 0 Q a 3 0 UPDATED TOP BRACES g w 0 0 a 1 fi O 1 ri r 1-4010-4005 w O t<v 90 1 a M z 1 s T N r ga 0 z aL FOzo Fclz OJ°wm zOzw OZUr vmm- nod<00 uiZ ctx co U)Uuu..z —)'�Z3 to 0 0wzro. Nonwce_O LLO nk owiTi Om 0 0re6F6 LOZ 0 000 om w-'yz Q r-132 z��.i oiv 1344 r FT?w, t...› \-- 114-L 4 '4 (o to - o (43 0„ 674 74g 7 Rc, g -) rw 4� 71),.i15 e f .S'% v„ Moore Engineering Group PROJECT: OJECT: ENGR: ((i'" ' F t DATE: (�/(' SCALE: )474 SHEET United Technologies SUBMITTAL Project NVBP Date Friday, March 23, 2018 REVIEWED FOR CODE COMPLIANCE APPROVED APR 122018 City of Tukwila BUILDING DIVISION MIS -otitis FILE RECEIVED CITY OF TUKWILA APR 04 2018 PERMIT CENTER 10T Pkg HP Project: NVBP 03/23/2018 Prepared By: 10:33AM 10T Pkg HP Tag Cover Sheet Unit Report Certified Drawing Performance Report Unit Feature Sheet Packaged Rooftop Builder 1.49f Page 2 of 11 Project: NVBP Prepared By: Unit Report For 1OT Pkg HP 03/23/2018 10:33AM Unit Parameters Unit Model' 50TCQD12A2A6-0A0G0 Unit Size. 12 (10 Tons) Volts -Phase -Hertz' 460-3-60 Heating Type Heat Pump Duct Cfg• Vertical Supply / Vertical Return Two -Stage Cooling Refrigeration Coil Lines and Filters Condensate Drain Line Size' 3/4 Return Air Filter Type. Throwaway Return Air Filter Quantity' 4 Return Air Filter Size 20 x 20 x 2 Unit Configuration Medium Static Option Belt Drive AI/Cu - AI/Cu Base Electromechanical Controls Standard Packaging 2 -Speed indoor fan motor controlled by VFD Warranty Information 5 -Year electric heaters (STD.) 1 -Year parts (STD.) 5 -Year Compressor (std.) Dimensions (ft. in.) & Weight (Ib.) *** Unit Length. 7' 4.125" Unit Width. 4' 11.5" Unit Height 4' 1.375" ••• Total Operating Weight 1227 Ib "' Weights and Dimensions are approximate. Weight does not include unit packaging. Approximate dimensions are provided primarily for shipping purposes. For exact dimensions and weights, refer to appropriate product data catalog. No optional warranties were selected. NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity 50TCQD12A2A6-0A0G0 Rooftop Unit 1 Base Unit Medium Static Option Belt Drive None 2 -Speed Indoor Fan (VFD) Controller Accessories CRHEATER113B00 15.2/16.5 kW 460/480-3-60, 11.5 kw 400-3-50 Volt Electric Heater 1 CRSINGLE047A00 Single Point Kit 1 CRECOMZR069A01 LOW LEAK - Vertical EconoMi$er 1 Packaged Rooftop Builder 1.49f Page 3 of 11 Certified Drawing for 10T Pkg HP EEP 0 :m 48TM502373 V CC 1- 1.1 CC w oM 1,4�- (Q 0 0 Packaged Rooftop Builder 1.49f Certified Drawing for 10T Pkg HP 0 co m Z -p U a p_ O 4) 21 11 0 CWs m CC CC 0 V O CL 0 U 0 CC 0 V F- 0 O COCCL. 48TM502373 � o 0 N f6 0 Packaged Rooftop Builder 1.49f M � CrOMetI 06/19/2017 Date: Weights: 70Ibs/31.75kg Units: Part Number: ECD-SRT34CA-D2DH Submitted To: shumphries@airefco.com Job: Notes: Economizer - Ultra Low Leak Economizer, Adjustable Dry Bulb Sensor, Honeywell Hardware Included. Economizer Harness with PL6 Plug CommunicatingOl`• Actuator External Gear Driven Dampers f Vertical Orientation, Actuator. Painted io I/ / / Knockouts Wiring for Optional Power Exhaust Rain Prop Honeywell Hood /. 23 Outside Sensor Jade W7220 Single/Multiple Speed With Aluminum Filter, Barometric Relief, Filter Access Door Provided on Unit 3/16" 22 3/8" Electromechanical Controller, All Necessary Panels And MicroMetl Economizer N __/Filters Barometric Relief Damper EconomizerI Air Hood � 4 . c Z . Side View The Information contained in this drawing is the sole property of Micrometl Corporation. Any reproduction in part or whole without the written permission of Micrometl Corporation is prohibited. Indianapolis_ 3035 N. Shadeland Ave., Indianapolis, IN 46226_800.MMC.HVAC •• Sparks_905 Southern Way, Sparks, NV 89431_800.884.4MMC •• Longview 201 Kodak Blvd., Longview, TX 75602_903.248.4800 MicroMetl Date: 6/19/2017 Weights: 701bs/31.75kg Units: Part Number: ECD-SRT34CA-D2DH Submitted To: shumphries@airefco.com Job: Notes: Economizer - Ultra Low Adjustable Dry Bulb Sensor, Hardware Included. Compliant Economizer: Leak Economizer, Vertical Orientation, Honeywell Jade W7220 Single/Multiple Speed Electromechanical Honeywell Actuator. Painted Rain Hood With Aluminum Filter, Barometric Relief, All Necessary Panels meet California Energy Commission Title 24-2013 / 2016 prescriptive section 140.4 (damper leakage etc.), and mandatory section 120.2.i for (JADE HJW10). meet ASHRAE 90.1-2013 / 2016 damper leakage requirements as stated in Table 6.4.3.4.3., and meet 2016 Fault Detection and Diagnosis 6.4.3.12. IECC 2012 section C402.4.5.2 and, IECC 2015 sections C403.2.4.3 and C403.3.3.5 for outside air, return air, and relief damper (when provided) 2015 section C403.2.4.7 for Fault Detection and Diagnostic requirements. Note: IECC 2015 section C403.2.4.7.1 requires differential return (i.e. D2XH) and must be ordered separately on others (i.e. D2DH, D2ZH). retum air (volume) dampers are AMCA Class 1A rated at 1" w.g. Refer to MicroMetl NS1 catalog sheet on web site for details. Relief air dampers rated. Refer to GR1 series catalog sheet on web site for details. indoor fan units with Central Terminal Board (CTB). Other control options available. trouble-free operation, eliminating slippage and binding associated with standard linkage. with aluminum water entrainment filters In the outside air section. water run-off. damper provided. Power exhaust options available. needed areprovided. access door shipped with HVAC unit. MicroMetl door option is installed on unit, an additional kit is required to seal hinged door properly. certifies GRI or MicroMetl part number 0640-0200-HDANGL herein the The based Honeywell W7220 JADE controller, mixed (supply) air temperature sensor, OA sensor in description, and spring -return procedures accordance (some include differential return sensor as noted). Publication is field mounted in unit's control box. comply of the is field installed in indoor blower fan section. Ratings - croRatings models or can orderedseparately P y "-D2XH" "-D2ZH" delbe MicroMetl PartNo.9901-2022-DIFF JC2)is field Thengs to Air Performance 24 require the economizer controller be capable of reporting faults to a fault management application accessible by service personnel, or annunciated locally on zone thermostats or in some codes other devices are acceptable. Refer to and to MicroMetl instructions for suggestions. models without the Central Terminal Board the "-D2"'part number is replaced by "-DJ". (See separate submittal). Controller, And Fault Detection leakage air sensor, which (when AIR IOWA AIR aro eenena �;;,�,m °,v nfDO,nnrfOt No nmxmeeon mrennmwnm. mo.^ 0 Corporation that the models and NSI shown are licensed to bear AMCA Seal. ratings shown are on tests and performed in with AMCA 511 and with requirements AMCA Certified Programs. S Certified Seal applies Leakage and Air ratings. 1. Title 24: Economizers and Diagnostic controls 2. ASHRAE 90.1: Economizers requirements in section 3. IECC: Economizers meet requirements, and IECC is included in some models 4. AMCA: Outside air and provided) are also AMCA Features:. • For single, 2 or 3 speed • Gear driven design for • Includes assembled rainhood • Rainhood is sloped for • Built-in barometric relief • All harnesses and plugs P 9 • Uses standard factory filter • If factory hinged access - OEM part no. CRPECONV004A00 Notes: 1. Control systems include communicating actuator 2. JADE W7220 controller 3. Mixed (supply) air sensor 4. Differential return sensor(includedinand-D installed in return duct. 5. ASHRAE, IECC, and Title day-to-day operating or applicable code requirements 6. For older single speed The Information contained in this drawing is the sole property of Micrometl Corporation. Any reproduction in part or whole without the written permission of Micrometl Corporation is prohibited. Indianapolis_3035 N. ShadelandAve., Indianapolis, IN 46226_800.MMC.HVAC •• Sparks_905 Southern Way, Sparks, NV 89431_800.884.4MMC •• Longview 201 Kodak Blvd., Longview, TX 75602_903.248.4800 0 1 0 1 38V S30NV83101 S3H3NI NI 3NV SNOISN3INI0 031d103dS 3SIMN9H10 SS31Nfl (oNIMVHO 3MVOS .LON 00) '031191HOHd SI 'N011VH0d800113W0801W dO NOISSIWa3d N3111HM 3H11l0H11M 310HM aO 121Vd NI NOI10f100Hd38 ANY N011VH0d1303113WOil0IW JO A1H3dOHd 310S 3H1 SI 9NIMVHO SIH/ NI 03NIV1N00 NOI1VWUOdNI 3H1 dl AB 03WJ3H0 AO 133HS OV 96/91/40 03HSIl9fld V 08V AU 03NOIS30 E9'99 1q 1H013M addV OHO 31V0 NOI1dIN0S30 003 08V AB NMVHO WOB-d3H WHIM 31VW )V ON '4Z 311114£1.HS '000H 0321 101011 NOI1d1110S301NVd IN-VM4£12JS-00H 11384111N li1Vd oog,-en me) x1-MMndwl t991.yee loom -AA'woos -zzerzoo(DM M'slro�um ti uolgvaodaoo paWo.+aJW V 3ZIS 0 N , .- e- N-•- '- N 1- d DESCRIPTION 20-5/8" x 36-3/16" x 1" ALUM FILTER CLIP, FILTER #10 X 5/8" SEAL-TEK SCREW INSULATION, 38.688 X 1.875 X .5 TOP, HOOD LEFT SIDE, HOOD RIGHT SIDE HOOD DIVIDER, HOOD BASE, HOOD 'FILTER ANGLE ACCESS DOOR HDD-SRT5WA DAMPER ASSY, HW 1POP-RIVET, 3/16" PART NUMBER 9460-8502 9908-0020 HDD34WAM01 HDD34WAM02 HDD34WAM03 HDD34WAMO5 HDD34WAM06 HDD34WAM07 J Q T N, Q V V 7 p 000.Cn 102 1< 0 O W N w 1- 0 0 0 • S FOR MORE DETAIL X N NMI 0 0 Q Certified Drawing for 10T Pkg HP 0 m >. m Z -p N U N O 2 CL CL A Service Clearance A:.3,„,,,,,,,r -,,,:s.i ,...::, C08537 CONDITION • Unit disconnect is mounted on panel • If dimension -8 is 12 -in (305 mm) • No disconnect, convenience outlet option • Recommended service clearance (use electric screwdriver) • Minimum clearance (use manual ratchet screwdriver) • Unit has economizer • If dimension -A is 36 -in (914 mm) • Check for sources of flue products within 10 -ft of unit fresh air intake hood • Side condensate drain is used • Minimum clearance charge accessory installed, surface is combustible material :hind servicer is grounded (e.g., metal, masonry wall, another unit) :hind servicer is electrically non-conductive (e.g., wood, fiberglass) adjacent units or building fresh air intakes within 10 -ft of this unit's NOTE: Unit not designed to have overhead obstruction. ContactApplication Engineering for guidance on any application planning overhead obstruction or vertical clearances. dams DIMENSION 48 -in (1219 mm) E E E E M vnl mec.9.....,-...-. Tc -E—VE E E m ti c E E N M a c E E E E W N ma.c+gcm c c E I E a, E N p c :2 f z 0 tQ Q m V 0 0 O a) 0) c0 a Packaged Rooftop Builder 1.49f Project: NVBP Prepared By: Performance Summary For 1OT Pkg HP 03/23/2018 10:33AM Part Num ber:5OTCQD12A2A6-0A0GO ARI EER 11.00 IEER 12.5 Base Unit Dimensions Unit Length. 88.1 in Unit Width* 59.5 in Unit Height 49.4 in Operating Weight Base Unit Weight 1050 Ib Medium Static Option Belt Drive. 15 Ib 2 -Speed Indoor Fan (VFD) Controller 20 Ib Accessories 15.2/16.5 kW 460/480-3-60, 11.5 kw 400-3-50 Volt Electric Heater 45 Ib Single Point Kit 12 Ib LOW LEAK - Vertical EconoMi$er 75 Ib Total Operating Weight' 1227 Ib Unit Unit Voltage -Phase -Hertz 460-3-60 Air Discharge' Vertical Fan Drive Type* Belt Actual Airflow. 4000 CFM Site Altitude 0 ft Cooling Performance Condenser Entering Air DB:__ 95.0 F Evaporator Entering Air DB* 80.0 F Evaporator Entering Air WB• 67.0 F Entering Air Enthalpy 31.44 BTU/Ib Evaporator Leaving Air DB* 59.6 F Evaporator Leaving Air WB. . 57.8 F Evaporator Leaving Air Enthalpy 24.87 BTU/Ib Gross Cooling Capacity' 118.20 MBH Gross Sensible Capacity 88.11 MBH Compressor Power Input' 10.84 kW Coil Bypass Factor 0.084 Heating Performance Outdoor Ambient Temperature. 47.0 F Entering Air Indoor Coil DB. 70.0 F Leaving Air Indoor Coil DB. 96.8 F Total Heating Capacity 115.90 MBH Integrated Heating Capacity' 115.90 MBH Heating Power Input' 11.27 kW High Temperature COP. 3.3 Low Temperature COP• 2.3 Electric Heating Capacity 15.20 kW Unit Leaving Air Temp 108.8 F Supply Fan External Static Pressure* 0.60 in wg Options / Accessories Static Pressure Electric Heaters* 0.08 in wg Economizer 0.20 in wg Total Application Static (ESP + Unit Opts/Acc.). 0.89 in wg Fan RPM• 872 Fan Power 2.08 BHP Packaged Rooftop Builder 1.49f Page 7 of 11 Performance Summary For 10T Pkg HP Project: NVBP 03/23/2018 Prepared By: 10:33AM NOTESelected IFM RPM Range: 733 - 949 Electrical Data Voltage Range' 414 - 506 Compressor #1 RLA. 7.7 Compressor #1 LRA' 52 Compressor #2 RLA. 7.7 Compressor #2 LRA. 52 Actual Electric Heater kW' 15.2 Electric Heater FLA. 19.8 Indoor Fan Motor Type' MED Indoor Fan Motor FLA 4.9 Power Supply MCA 51 Power Supply MOCP (Fuse or HACR). 60 Disconnect Size FLA. 50 Disconnect Size LRA 179 Electrical Convenience Outlet None Outdoor Fan [Qty / FLA (ea)]' 1 / 3.1 Electric Heater Number of Stages. 1 UNIT(s) INSTALLATION LOCATION Control Panel SCCR: 5kA RMS at Rated Symmetrical Voltage Acoustics Sound Rating 87.0 db Sound Power Levels, db re 10E-12 Watts Discharge Inlet Outdoor 63 Hz 90.7 86.5 88.1 125 Hz 85.9 80.0 90.0 250 Hz 72.4 67.0 85.9 500 Hz 71.7 66.5 83.0 1000 Hz 70.3 65.1 81.6 2000 Hz 67.0 59.4 78.5 4000 Hz 67.8 56.9 76.4 8000 Hz 64.1 51.0 75.5 A -Weighted 76.9 70.6 87.0 Advanced Acoustics Advanced Accoustics Parameters 1. Unit height above ground' 30.0 ft 2. Horizontal distance from unit to receiver 50.0 ft 3. Receiver height above ground' 5.7 ft 4. Height of obstruction' 0.0 ft Packaged Rooftop Builder 1.49f Page 8 of 11 Performance Summary For 10T Pkg HP Project: NVBP 03/23/2018 Prepared By: 10:33AM 5. Horizontal distance from obstruction to receiver 0.0 ft 6. Horizontal distance from unit to obstruction. 0.0 ft Detailed Acoustics Information Octave Band Center Freq. Hz 63 125 250 500 1k 2k 4k 8k Overall A 88.1 90.0 85.9 83.0 81.6 78.5 76.4 75.5 94.0 Lw B 61.9 73.9 77.3 79.8 81.6 79.7 77.4 74.4 87.0 LwA C 55.7 57.6 53.5 50.6 49.2 46.1 44.0 43.1 61.6 Lp D 29.5 41.5 44.9 47.4 49.2 47.3 45.0 42.0 54.6 LpA Legend A Sound Power Levels at Units Acoustic Center, Lw B A -Weighted Sound Power Levels at Units Acoustic Center, LwA C Sound Pressure Levels at Specific Distance from Unit, Lp D A -Weighted Sound Pressure Levels at Specific Distance from Unit, LpA Calculation methods used in this program are patterned after the ASHRAE Guide; other ASHRAE Publications and the AHRI Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program, it is assumed that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space, an Acoustical Engineer or a person with sound prediction expertise should be consulted. Packaged Rooftop Builder 1.49f Page 9 of 11 Project: NVBP Prepared By: Performance Summary For 10T Pkg HP 03/23/2018 10:33AM 20 1 1 FanCurve 05 10 15 20 25 30 35 Airflow(CFM-thousands) RPM=872 BHP=2.08 MaximumRPM=1400 MaximumBHP=3.70 Note: Pleasecontactapplicationengineeringforselectionsoutsidetheshadedregion. SC -System Curve RP-RatedPoint Packaged Rooftop Builder 1.49f Page 10 of 11 ` ILORPM __ � ____'- `mill 11. 1111 3.70BHP� 70DRPM Ma= &EA E _ ISIRPM 3.00B� SIM MI 2.00BHP Ell ____ IMIEMINI ERIENIM MITINI __ -�O.EOBHP� 1,- ' 1111 1111 _ 1111 111 1111 111 1111 1111 _1 05 10 15 20 25 30 35 Airflow(CFM-thousands) RPM=872 BHP=2.08 MaximumRPM=1400 MaximumBHP=3.70 Note: Pleasecontactapplicationengineeringforselectionsoutsidetheshadedregion. SC -System Curve RP-RatedPoint Packaged Rooftop Builder 1.49f Page 10 of 11 Project: NVBP Prepared By: Unit Feature Sheet for 10T Pkg HP 03/23/2018 10:33AM WeatherMake '- 5OTCQ PACKAGED ROOFTOP HEAT PUMP UNITS 3, 4, 5, 6, 7-112, 8-112,10 and 12.5 TONS 50TCQ units are high -efficiency single -packaged heat pump units that are pre -wired and pre -charged with PURON (HFC) refrigerant. Electric heat is available as a field -installed accessory. The units are fullyfactorytested and agency certified. COMPLIANT,' US i•+u� GERTt� R,EIa_ Certified to ISO 9001 PERFORMANCE FEATURES • PURON (R -410A) HFC refrigerant • ASRRAE 30.1 energy compliant • SEERsupto 13.4, EERs up to 11.2 • IEER's up to 12.2 • HSPF'sup to 7.7 and COP's up to 3.3 • Single stage cooling capacity oontroion 04-07 models • Two -siege cooling cspsctycontroion08- 14 models • Exc'.us've non -co r_rO sive cxtmoasitecondenseta. pan in accordance 'with ASHRAE 52 Standard. sloping design; side orcenter drain • Field convertible from vertical to horizontal airflow on all models, No spectelkit required on 34-12 models. Supply duct k't required for 14 size model only-. • oppertube aluminumfin ,cars with optio ne I co rrosio n resistant co its • Pre -painted exterior panels and prim== -roosted interior panels tested to 530 hours salt spray protection • Aoutro"" refrigerant metering system • .Cooling operating -range up to 115F {45C) end down to 25F (-4C) • Solid-state control board and easy access terminal board • Refrigarantfita.. drier end accumu'.storon each refriga--rent circuit • Fulryyinsulated cabinet • Automatic changeover when used with auto -changeover thermostat • Rated in accordance With AHRI Standards 240 (04-05 sizes) and 340 (07-14) • Designed tri accordsncewith Underwriters" LaboratoriesStandard1835 • Listed by UL. end UL, Canada MAINTENANCE FEATURES: • Ann s panelswth ea sy grip handles • Innovative, easy starting. no strip screw features on unitaco=,ss panels. • Two-inch disposable return air filters • Tool -less filter access door • Salt drive eveporato fen motor and pulley comb mations ave liable on all sizes to meet anyapp kation • Electric Drive x13(5 sp=_editorqu ))mothron04 to 05 models • Cantel temninaI board faotillating simple safety c!rou it troubleshooting and slrnptfied control box sire nge ment INSTALLATION FEATURES: • Th ru-the-bottarn power entry ce p s bitty standard • Single point electric connections • Fultperimeterbase rail with bolt --'in rigging adapters end fork truck slots RELIABILITY FEATURES: • Scro71 compressors with internal tineb reale overload protection • Dependable Time !Temperature defrost board and logic • 24 -volt co ntroioi cut Protected with resetteble circuit breaker • Pennon'_ntlyiubricata_deve poo-rator-fanmotor • Totally enclosed oonde nsermotors with permene ntly lubricated bearings • Loss of oherge. freeze protection, and high-pressure switches STANDARD WARRANTY: • 5-yea:rataotro bastes • 5 -ye er compressor • 1 -year parts 6lenyoptonalwarranras also available OPTIONS INCLUDE BUT ARE NOT LIMITED TO: • !9uti Protocol (RTU Open) and Prem`.erLink^' Direct Digital Controllers • !VD n-fuseddisconnect switch • Economze*options for electro -mechanical and 000 control • Corrosion resStant cot optionsfor evaporator and condenser • Optionanndoo• fan motors for expanded airflow cep eb iiity • Acre ssorgelectrcheat (fie td--installed option only) • Smoke detectors -Supply and Return air • Hinged aoxss panels Packaged Rooftop Builder 1.49f Page 11 of 11 z O APPROVED O 0 V 0 UPDATED TOP BRACES C r O 0 17 9116" 1 - Ir r 0 1-w 0 0 DO ZU CD 0 0 #t W 0 1- o 0 0 E O 3:58:08 PM E z CNJ5252 ori M N iT .e 0 Z <L O Z _ JWuim O Z to U=m- 01— Ce M01:2 U Z a=U-0 O y�OZZ L VOLI<00=ULLZ ZF0U W Ug xw,Zo �N?�O WO c4 cottiw D O F LL E2 PROJECT DESCRIPTION: 1 REPLACE (1) 10 -TON ROOF MOUNTED PACKAGED HEAT PUMP WITH NEW 10 -TON ROOF MOUNTED PACKAGED HEAT PUMP WITH ECONOMIZER. ParcelNumber . : MECH-SUM 252304.-9017 Name ' Project Title: NORTHWEST ACCESSORIES: TERRENO 17600 WVH LLC Site Address : 17600 WEST VALLEY HWY 98188 .. Legal . . Applicant Name: JESSE CHUTICH S 329.55 FT OF GL 7 LY BET PST.& P RAM & CO RD LESS ST HWY GENERAL NOTES: 1. ECONOMIZER TO PROVIDE 100% OUTSIDE AIR WITH PARTIAL COOLING AND MULTIPLE COOLING STAGES. 2. ANCHORAGE: (3) #10 SMS PER SIDE. 3 THERMOSTAT TO PROVIDE MINIMUM 5° DEADBAND. 4.7 -DAY PROGRAMMABLE THERMOSTAT WITH LOCKOUT. 5. INSTALL GFCI OUTLET WITHIN 25' OF UNIT STALL RETURN AIR DUCT SMOKE DETECTOR FOR UNITS WITH GREATER THAN 2,000 CFM. 7. PROVIDE COMMISSIONING REPORT. HVAC Equipment Schedule (New) Brand Model Ton RTU -1 Carrier 50TCQD12A2 10 Total CFM Cap. Heat 116,000 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 Mechanical Summary 2015 Washington State Energy Code Compliance : MECH-SUM Forms for Commercial Buildings including R2 & R3 over 3 stories and all Rt Revised January 2017 Project Information Project Title: NORTHWEST ACCESSORIES: Date 1/1/2015 Applicant Information. Provide contact information for individual who can respond to inquiries about compliance form Information provided. For Building Dept. Use Company Name: COMFORT MECHANICAL Company Address: 3202 C ST NE AUBURN, WA 98002 Applicant Name: JESSE CHUTICH Applicant Phone: 425 2519840 Project Description : Briefly describe mechanical systems In the text box provided OTotal Bldg Performance (TBP) This path includes alt mandatory provisions per C401.2 Option 2 MECH-SUM, MECH-CHK, and C407 Energy Analysis forms required. 2.08 ' [New I3uilding 1 Building Addition QTenant Improvement 0 System Retrofit ■ No. System Changes REPLACE (1)10 -TON PACKAGED HEAT PUMP WITH NEW SAME CAPACITY UNIT. Design Load Calculations heating, cooling or Includes all applicable • Load calculation summary 1 MECH-LOAD-CALC Form Provide design load calculations for all mechanical systems and equipment serving the building ventilating needs. If a load calculation summary Is provided with the permit documents that compliance information then the MECH-LOAD-CALC formas not required Mechanical Schedules forms are not required, 12 Mechanical Plans • MECH-EQ Forms (TBD) Indicate location of equipment compliance information. If provided on plans then MECH-EQ however, include on plans all applicable compliance fnfomtation listed In MECN-EQ tables.. Dedicated Outdoor Air System Requirements and High Efficiency VAV Alternate fire station occupancies) air In a manner that does heating or cooling Is required. Exception 1) of DOAS (0403.6, Exception library or tire station) C402.4.1.4 with 100% of • DOAS is required per C403.6 effective July 1, 2017 (office, retail, education, library and All occupied, conditioned areas shall be served by a DOAS that delivers required ventilation not require space conditioning fan operation. Space conditioning fans cycled off when no 1 Ventilation provided via natural ventilation per 2015 IMC In lieu of DOAS (C403.6, ■ and space conditioning provided by a HEVAV system per C403.7 in lieu Ventilation 1 DOAS included in project, although not required (occupancy not office, retail, education, • DOAS related allowances included in project i0 Prescriptive vertical fenestration maximum area allowance increased to 40% per conditioned floor area In building served by DOAS. 11 Exception to air economizer per C403.3 Exception 1, Include MECH-ECONO form. Fan Power exceeds 5hp. 5 horsepower threshold. is Project includes HVAC air distribution systems that provide heating and/or cooling If yes, provide a MECH-FANSYS -SUM form. • For one or more systems, the total fan motor nameplate hp of all fans In HVAC system If yes, provide a seperate MECH-FANSYS form for each HVAC system exceeding the Refer to Section C403.2.11. and MECH-FANSYS-DOC for requirements and exceptions. HVAC Hydronic Systems • Hydronic chilled water • Water -loop heat pump 12 No hydropic systems li Hydronic heating water 0 Geothermal C406 Additional Efficiency Options - MechanicalRequires C406.2 More efficient HVAC equipment and fan systems Requires 90% of heating and cooling capacity to be equipment listed in tables C403.2.3(1)-(9) pumps and heat recovery chillers. All equipment listed to tables C403.2.3(1)-(7) must minimum requirements. Al! stand alone supply, return, and exhaust fans over 1hp must selected within 10% of maximum total or static pressure. or alr-to-water heat be 15% more efficient than have FEQ z 71 and must be required ventilation air in a annual hot water energy use be • C406.6 Dedicated outdoor air system (DOAS) 90% of conditioned floor area to be served by a DOAS per C403.6 that delivers manner that does not require space conditioning fan operation.: • 3406.7 Reduced energy in service water heating Requires 90% of floor area be in occupancy types listed In C406.7.1 and that 60% of provided by heat pump, waste heat recovery or solar water -heating systems. Cap. Cool 118,000 ARI EER 11. Weight 1227 Sound(bels) 87 Location Roof SE , .\RA i E PERMIT ::.(2UIRED FOR: 0 Mechanical G7'lectrical tumbing las Piping 1 ✓ of Tukwila 6 DIVISION REVISIONS No changes shalt be made to the scope of work without prior approval of Tukwila Building Division. • NOTE. Revisions Will require a new plan submittal 1 and may include additional plan reviewfees. ... COPY Permit Noe (9)-- 0014 Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Co . and conditions is acknowledged: By: Date: —= V/ City of Tukwila BUILDING DIVISION D RTUS NO WORK REVIEWED FOR CODE COMPLIANCE APPROVED APR 12 2018 City of Tukwila BUILDING DIVISION 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 Mechanical Fan System Power Allowance MECH-FANSYS-SUM 2015 Washington State Energy Code Compliance Forms for Commercial Buildings includine R2 & R3 over 3 stories and all R1 R d J Project Title: NORTHWEST ACCESSORIES erose anuary 2017 Date 1/1/2015 For Building Dept. Use HVAC Air Distribution System Schedule List all HVAC systems that have the capability to provide heating and/or cooling to the spaces they serve. System or Primary Supply Fan ID Speed Control (Note 1) Description (Note 2) System Total Nameplate HP (Note 3) Fan Power Calculation Required (Note 4) RTU -1 CV HEAT PUMP 2.08 ' No REC CITY OF APR PERMP Note 1- Constant Volume (CV), Variable Air Volume (VAV), or Hospital/Lab CV system that qualifies for VAV budget per C403.2.11.1 Exception Single zone VAV systems shall comply as CV. Note 2 - Describe system type and list all fans (or groups of fans) associated with the delivery and removal of conditioned air by the system. all supply, return/relief, exhaust and exhaust hoods (>1 hp), make-up air, dedicated outside air (DOAS), booster fans, and series terminals. VAV parallel fan -powered terminals and economizer relief fans do not need to be included if the fans do not operate at conditions. . Note 3 - Enter the total nameplate hp of all fans associated with the delivery and removal of conditioned air by the system. Note 4 - This form automatically identifies whether a MECH-FANSYS form is required to demonstrate compliance with the fan power allowance or this information is not required because the system has a combined total nameplate motor hp that is 5hp or less (No) 1. Include fan -powered peak (Yes), MECH-FANSYS Forms A MECH-FANSYS form shall be provided for each system with total nameplate hp greater than 5 hp. Select (Add Fan System Form) to generate an additional four. Added forms can be deleted with button in cell E32 of the added form. _W Et O- (J)›- UW J 0000 . J 075 W W LL O D DATE• CHECKED cIVED TUKWILA 4 2018 CENTER NORTHWEST ACCESSORIES ROOF PLAN - NO SCALE 9/5/2018 City of Tukwila Department of Community Development JESSE CHUTICH 3202 C ST NE AUBURN, WA 98002 RE: Permit No. M18-0045 NW ACCESSORIES 17616 WEST VALLEY HWY Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 10/30/2018. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 10/30/2018, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: M18-0045 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COPY � PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M18-0045 DATE: 04/04/18 PROJECT NAME: NW ACCESSORIES SITE ADDRESS: 17616 WEST VALLEY HWY X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: Acy mac, t-5-1 Building Division s Fire Prevention AM Mic Public Works n Structural Planning Division ❑ Permit Coordinator w PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 04/05/18 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 05/03/18 Approved Corrections Required ❑ Approved with Conditions ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: 7W_S pv)Ve_s cY'r‘ IPLI"9 REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping 0 PW 0 Staff Initials: 12/18/2013 COMFORT MECHANICAL INC ( Page 1 of 2 Horne Espanol Contact Search L&I A -Z Index Help My 1: &I Safety & Health Claims & Insurance Workplace Rights Trades & Licensing Washington State Department of 16,40 Labor & Industries COMFORT MECHANICAL INC Owner or tradesperson Principals JACKSON, SHIRLEY A, PRESIDENT JACKSON, HERB J, VICE PRESIDENT Doing business as COMFORT MECHANICAL INC WA UBI No. 601 954 041 3202 C ST NE AUBURN, WA 98002 425-251-9840 KING County Business type Corporation Governing persons HERB J JACKSON SHIRLEY A JACKSON; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties HeatingNent/Air-Conditioning and Refrig (HVAC/R) License no. COMFOM1015LA Effective — expiration 06/01/1999— 04/25/2020 Bond ............._ Lexon Ins Co Bond account no. 9815017 $6,000.00 Received by L&I Effective date 06/04/2012 06/01/2012 Expiration date Until Canceled Bond history Insurance AMCO Ins Co $1,000,000.00 Policy no. ACP3008276478 Received by L&I Effective date 05/24/2017 06/01/2017 Expiration date 06/01/2018 Insurance history Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601954041 &LIC=COMFOMI015LA&SAW= 04/16/2018 COMFORT MECHANICAL INC Savings 9during previousy period. savings accounts the 6 ea.•penod. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts ......................................... No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations .................................................... No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID 973,224-00 Doing business as COMFORT MECHANICAL INC Estimated workers reported Quarter 4 of Year 2017 "11 to 20 Workers" L&I account contact T3 / KENT ANDERSON (360)902-6963 - Email: ANDN235@Ini.wa.gov Account is current. Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes ........................................................ No strikes have been issued against this contractor. Contractors not allowed to bid ...................................._..........................._......................... No debarments have been issued against this contractor. Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 10/16/2012 Inspection no. 316456144 Location 444 Valley Mall Parkway East Wenatchee, WA 98802 Violations Page 2 of 2 © Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601954041 &LIC=COMFOMI015LA&SAW= 04/16/2018