HomeMy WebLinkAboutPermit M18-0046 - OLIVE GARDEN - RTU REPLACEMENTOLIVE GARDEN 310 STRANDER BLVD EXPIRED 06/18/2019 MI 8-0046 Parcel No: Address: 0 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov 9202470040 310 STRANDER BLVD Project Name: OLIVE GARDEN MECHANICAL PERMIT Permit Number: M18-0046 Issue Date: 7/11/2018 Permit Expires On: 1/7/2019 Owner: Name: Address: Contact Person: Name: WESTFIELD PROPERTY TAX DEPT PO BOX 130940 , CARLSBAD, WA, 92013 ALEX SOKIRKIN Address: 11227 217 ST CT E , GRAHAM, WA, 98338 Contractor: Name: PACIFIC REFRIGERATION UNLMTD (CONSTRUCT) Address: PO BOX 1557 , TACOMA, WA, 98401 License No: Lender: Name: Address: PACI FRU831J0 Phone: (253) 341-1167 Phone: (253) 292-8728 Expiration Date: 4/20/2019 DESCRIPTION OF WORK: REPLACE THE CURRENT RTU #1 WITH A NEW CUSTOMER PROVIDED RTU. WE ARE ONLY PROVIDING LABOR, NO EQUIPMENT. SAME LIKE FOR LIKE UNIT CHANGE OUT. SAME EXACT SIZE AND TYPE. Valuation of Work: $3,000.00 Type of Work: REPLACEMENT Fuel type: GAS Fees Collected: $245.69 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Permit Center Authorized Signature: • Date: 07//(Z I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: ." Print Name: E\ -if 1(.,k40 (DAIS K, Date: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: Readily accessible access to roof mounted equipment is required. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: ***MECHANICAL PERMIT CONDITIONS*** 10: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 11: Manufacturers installation instructions shall be available on the job site at the time of inspection. 12: The attached set of mechanical plans have been reviewed by The Tukwila Fire Marshals Office and are acceptable with the following concerns: 13: H.V.A.C. units rated at greater than 2,000 cfm require auto -shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2437) 14: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air -moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 15: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2437) 0 16: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2437) 17: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 18: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 19: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 20: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 21: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1400 FIRE FINAL 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL 0702 SMOKE DETECTOR TEST CITY OF TUKW!'`Ti Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 hap://w ww.TukwilaWA.gov 0 Mechanical Permit No. Mt 00q'ta Project No. Date Application Accepted: Date Application Expires: JO( (For office us only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION 0l ‘te... / Qr j f King Co Assessor's Tax No.: Site Address: 31 D I1 C-Ct i► tt.d. Suite Number: Tenant Name: d f ue- PROPERTY OWNER Company Name: S i%,��1 l ./',i,,i, V'W,);•,„..w GI 7 Name: Ala a hko vi Name: Address: O` `�^�xjll� 1 �s3 17� 1 Contr Reg No.: CC Peel F e ; r xp Date: Libo i, � Address: 01 Phone: X53) 3 iii46...3 Fax: �(�//� City: State: Zip: CONTACT PERSON — person receiving all project communication Company Name: S i%,��1 l ./',i,,i, V'W,);•,„..w GI 7 Name: Ala a hko vi City:�ju �,, w4 Zip:Gt gL/0 I 11 Address: O` `�^�xjll� 1 �s3 17� 1 Contr Reg No.: CC Peel F e ; r xp Date: Libo i, � State: pip Zip:q City:C{C(1/hq 01 Phone: X53) 3 iii46...3 Fax: �(�//� Email: ,44 // � t Cr Grdr\i/`F ia-r-crA'viLCc. cel New Tenant: Floor: N1 ❑ Yes ❑.. No MECHANICAL CONTRACTOR INFORMATIONr Company Name: S i%,��1 l ./',i,,i, V'W,);•,„..w GI 7 Address: 0, 12 0)(.. 155? l�State: City:�ju �,, w4 Zip:Gt gL/0 I 11 Phone: C?- i) 2.4:12, -q7 -2g Fax: `:4 1 Contr Reg No.: CC Peel F e ; r xp Date: Libo i, � Tukwila Business License No.: Valuation of project (contractor's bid price): $ 3, Cep Describe the scope of work in detail: ?IC/G� 1 t/rre.4- kr.4i UlJi-I VL q (l 04/ C4'CcAqoA.e. fervileA PTLI.'I Cth f� ace t.. T I del y �roc9 TU;�1�� fl lo/, ', /to �-y 14 r �% 1 h9 A 5'Q "K. ! 11�+� Cor Nee- G�u��2 • Sana eXa S' 2e- G^ j "type_ Use: Residential: New ❑ Replacement Commercial: New ❑ Replacement Fuel Type: Electric 0 1.41 Gas Other: H:\ Applications\Forms-Applications On Line \2016 Applications\Mechanical Permit Application Revised 1-4-16.docx Revised: January 2016 bh Page 1 of 2 1 � 1 •y • .J r, 1 1 • l 1 Indicate type of mechanical work being installed and the quantity below: • )1 4 Unit Type , Qty' , Furnace <100k btu Residential, Nighttime Furnace >100k btu Industrial Floor furnace 55 dB(A) Suspended/wall/floor mounted heater 57 dB(A) Appliance vent Commercial Repair or addition to heat/refrig/cooling system 47 dB(A) Air handling unit 65 dB(A) <10,000 cfm 60 dB(A) .t Unit Type Qty Air handling unit Residential, Nighttime >10,000 cfm Industrial Evaporator cooler 55 dB(A) Ventilation fan connected to single duct 57 dB(A) Ventilation system Commercial Hood and duct 47 dB(A) Incinerator — domestic 65 dB(A) Incinerator — comm/industrial 60 dB(A) Unit Type Qty Fire damper Residential, Nighttime Diffuser Industrial Thermostat 55 dB(A) Wood/gas stove 57 dB(A) Emergency generator Commercial Other mechanical equipment 47 dB(A) 60 dB(A) 65 dB(A) Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-IOPM, Monday through Friday and 8AM-10PM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: • Warning devices; • Construction and property maintenance during the daytime hours (7am-lOpm); • Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name: 4kx Soki rkv, Mailing Address: P, 0, 061( 1 H:\Applications\Forms-Applications On Linc\2016 Applications\Mechanical Permit Application Revised 1-4-16.docx Revised: January 2016 bh Date: Day Telephone: 0253) Si** -4 !G 4. City (A14 SYN State Zip Page 2 of 2 DESCRIPTIONS I PermitTRAK ACCOUNT I QUANTITY PAID $245.69 M18-0046 Address: 310 STRANDER BLVD Apn: 9202470040 $245.69 Credit Card Fee $7.16 Credit Card Fee R000.369.908.00.00 0.00 $7.16 MECHANICAL $229.36 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $150.34 PLAN CHECK FEE R000.322.102.00.00 0.00 $45.87 TECHNOLOGY FEE $9.17 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R14174 R000.322.900.04.00 0.00 $9.17 $245.69 Date Paid: Friday, April 06, 2018 Paid By: ALEKSEY SOKIRKIN Pay Method: CREDIT CARD 416031 Printed: Friday, April 06, 2018 12:13 PM 1 of 1 CRWSYSTEMS INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT N CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pro' ct:, Live, G,*4ey,Sri Type of Inspe ion. -resit Address: E. VOL ec Date Called: Special Instructions: -* R 14.4x,-.EAts-k- - U RI -A& (Li i[.c-xr Ltk,e) Dat anteed: —/� -20ti p.m. Requ ter: i Phone No: 1 z.53 -3q)- `1 1 �^ 6 1 ElApproved per applicable codes. Corrections required prior to approval. COMMENTS - ems, , � p7 )1-14eS olcc �� �r <<� w r/ T M - e,e e Inspector:To ov Date -��-20Jr REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION ale 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Project: eL/4 Tie1W, 1/ Type of Inspection: , IICA. ANAL Address: 3/0 57144.1eldR aL 11�. ,, Date Called: Special Instructions: Date Wanted: Requester: Phone No: 153''398' -329 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: /f -.d ?t) 42x'farA 1,-/ Inspector: 0c -- Dater REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit nAIS --coo LIO PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project:/ VL/I/,2' goWir..41 Type of Inspection: /►'lk'eimo ni. .11.11-c._ Address: 3/0 e'NI,t)D R ,8L✓A Date Called: Special Instructions: RTU Cfir3/ our' Date Wanted: 8-10 -is p.m. Requester: Phone No: LJApproved per applicable codes. Corrections required prior to approval. COMMENTS: it/d coif T /x.741 ec44/77/eT - - '/11-1, —ei, Ds) - Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: ,,�� t¼97 T' F1l of Type of I specti n: ,k/s Address:Contact Suite #:f �77247'027 Person: Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Flood & Duct: ----- NO "Ali'747(17 Permits: Occupancy Type: --• l t_(4y&4 Citi ivU A/ -- i X76..7_(*,n_---7- ,27 -ii 4- #7 /1 -ca" ft Avao°7~-ci,/45,:e_ /(4•At, Ai&w)0..-.-b _ — _ .e.,-- — Sp/fa-ei 15-7-4( eitewrf Needs Shift Inspection: Sprinklers: Fire Alarm: Flood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector:, 670 6-3 Date: /213/45 j/45 Hrs.: /f 0 $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from e ity of Tukwila Finance Department. CaII to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 SITTS & HILL ENGINEERS, INC. Professional Engineers and Planners 4815 Center Street, Tacoma, WA 98409 www.sitts-hill-engineers.com (253) 474-9449 April 5th, 2018 PACIFIC REFRIGERATION UNLIMITED 4624 16th Street East, Suite A-8 Fife, Washington 98424 TO: Alex Sorkirkin •, I BRENT K. LESLIE, P.E. KATHY A. HARGRAVE, P.E. LARRY G. LINDELL, P.E. MICHAEL A. McEVILLY, P.L.S. SUBJECT: STRUCTURAL REVIEW OF REPLACEMENT HVAC UNIT — OLIVE GARDEN RESTAURANT, LOCATED AT 310 STRANDER BOULEVARD, TUKWILA, WASHINGTON SITTS AND HILL PROJECT NUMBER 17799 Dear Alex, We understand that you are proposing to replace the existing 10 ton rooftop mounted air handling unit (RTU1) at 310 Strander Boulevard in Tukwila, Washington. The new unit will be a 10 ton capacity Trane model YHC120F3RHA. A Curb adapter will also be installed. The existing unit is a Lennox Model LGC120. It weighs approximately 1,355 lbs. The proposed unit weighs approximately 1,259 lbs. The proposed curb adapter weight 259 lbs. installation of the proposed equipment will increase the unit weight by approximately 165 lbs. The existing roof supports several HVAC units, fans and a make-up air unit. The structural elements supporting the proposed replacement unit also support a minimum of two other units. The additional 165 lbs. load results in a dead load increase of less than 5%. Based on the 2015 International Existing Building Code 707.2, this is structurally acceptable. Thank you for the opportunity to provide structural engineering services. office with any additional questions or comment regarding this p Sincerely, Sitts and Hill Engineers, Inc. /Irt d Brown, P.E. Senior Project Engineer 1779 • t 04 .Qf aciflc Refri • eration REVIEWED FOR CODE COMPLIANCE APPROVED P eiget.fie9 t€hGontact-our I it • �t Jtrtl 18 MO MAY 01 2018 City of Tukwila BUILDING DIVISION Civil, Structural and Survey RECEIVED CITY OF TUKWILA APR 0 6 2018 PERMIT CENTER OKCC MANUFACTURING PHONE: 800-382-2872 FAX: 502-491-1739 NEW UNIT: YHC120F EXISTING UNIT: LGC120 ADAPTER WEIGHT: 261Ibs DRAWING #: KCC-131067 TAG: QUOTE: E2018-03-1011 STATIC PRESSURE LOSS NEW UNIT CFM INCHES OF H2O 4000 0.060 3000 0.035 0 0.000 INSTALLATION INFORMATION: CONTRACTOR MUST COMPARE THE DIMENSIONS OF THE EXISTING CURB ON THE PROJECT TO THE DRAWING(S) PROVIDED. THE INSTALLATION CONTRACTOR IS RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF THE INSTALLATION SITE. WHEN CALCULATING THE UNIT REQUIREMENTS, THE EXTERNAL STATIC PRESSURE MUST BE TAKEN INTO CONSIDERATION. ANY DIMENSIONAL MODIFICATIONS TO STANDARD KCC ADAPTER DESIGNS WILL RESULT IN A MINIMUM ADDITIONAL CHARGE OF $100 PER DESIGN AND WILL RESULT IN A MINIMUM OF (3) DAYS TO THE STATED LEAD TIME. FEATURES: ADAPTERS ARE ASSEMBLED BUT MAY HAVE REMOVABLE FILLER PANS FOR FIELD INSTALLATION. ALL WELDS ARE COATED WITH A RUST INHIBITOR. ADAPTERS ARE FULLY INSULATED. INTERNAL DUCT TRANSITIONS INCLUDED. KCC RESERVES THE RIGHT TO MAKE DESIGN MODIFICATIONS WITHOUT NOTIFICATIONS. Print Name: Signature: Date: APPROVED RECEIVED CITY OF TUKWILA 54 1/4" KCC-131067 PERMIT CENTER OEM CURB W6/00144 • • KCC MANUFACTURING Adapter: KCC-131067 Quote: E2018-03-1011 Height: 16" 2715 Grassland Drive Louisville, Kentucky 40299 Phone: 800-382-2872 Fax 502-491-1739 For Office Use: LB64 1 TT95 1 GTG Old Model: LGC120 544 3l8 958 302 21i New Model: YHC120F 3 2 1$ — 8'�8 --18 -- 1i' 8 C 1 —182 `14 — 362 14 59 114 34 t Z 8 STATIC PRESSURE LOSS NEW UNIT CFM INCHES OF H2O 4000 0.060 3000 0.035 0 0.000 KCC curb adapters allow 1.5" (3/4" on every side) clearance around existing curb as shown. Any modification to KCC design will require extended lead times and result in additional engineering charges The new and old curb prints are provided for dimensional verification only and do Not indicate new unit orientation. KCC will Not be responsible for field clearance issues. TRANE Prepared For: Darden Job Name: OG #1584 Tuk Proposal Date: March 1, 2018 No changes shy" - . e , r() ;rnrc- of work vanthol pr ,' '{' p'i'opostal Number: H3-161590-1 Tukw la E31i ' ,; ;:7 D'v's:r'; it�i i� 4�il ibct rglil rE uirc .1 he 1 p'2n yibrn,tt, and may in:,,ud'' ad''.t onai p,an Delivery Terms: Freight Allowed and Prepaid - F.O.B. Factory Net 30 Days Payment Terms: SERA ❑Mechanical g‘Electrical 'Plumbing ISAas Piping City of Tukwila BUILDING DIVISION Trane U.S. Inc. is pleased to provide the following proposal for your review and approval.. Only those items specifically listed are included in this proposal. Pricing is based on unit replacement request form. No plans, specifications or addendums are acknowledged. Taco Data - 3-10 Ton R410A PKGD Unitary Gas/Electric Rooft Item Tag(s) Qty Description Model Numb�r��� � ' Al AC -1 Kitchen 1 10 ton high R410A 1 ISS. 4F Rt.,� oocitk oAp10 l��IPP000000000 Product Data - 3-10 Ton R410A PKGD Unitary I Fe R ttop Item: Al Qty: 1 Tag(s): AC -1 Kitchen DX cooling, gas heat High efficiency Convertible configuration 10 Ton Major design sequence 208-230/60/3 Microprocessor controls 3ph High gas heat 3ph Hinged panels/2 in pleated filters Mery Standard condenser coil w/hail guard Through the base electrical 3ph Circuit breaker Powered convenience outlet (3ph units) Frostat 3ph ° Discharge air sensing tube 3ph Dry bulb economizer 0-100% w/o bar rel (Fld) Reference enthalpy kit (Fld) 10 Year heat exchanger warranty Curb Adapter (Fld) Preprogrammed Thermostat and sensor (Fld) Darden proposals only Trane will not be supplying duct detectors. them in the ductwork. Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted coda or ordinance. Receipt of approved Field Copy conditions is acknowledged: By: 8 Date: 7/1 )/ RECEIVED City of TukavitATY OF TUKWILA BUILDING DIVISIONAPR 0 6 2018 Notes: 1) If not specifically listed, extra filters, isolation, roof curb, hurric are not included. Labor 2) This is a scope only prop Account agreement. Stacey Abbott - Trane National Account Job Coordinat 2301 Lucien Way, Suite 430 Maitland, FL 32751 Phone: (407)660-1111 Fax: (407)660-0303 ne ; •i! • f r PERMIT CENTER •o extra belts, extra sheaves, external alculations, condensate overflow switch and start up installing contractor if not purchased. uipment will be pre -purchased through their National JU1 18 X11 ... W i6 -may t GOMPLciAME APPROVED MAY 01 2018 City of Ih BUILDING DIVISION J:IJOBS1431161590111OG #1584 Tukwila WA AC -1 Kitchen Equipment Scope .doc t,, OG #1584 Tukwila WA AC -1 Kitchen Unit Dimensions - 3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: Al Qty: 1 Tag(s): AC -1 Kitchen March 1, 2018 3/4"-14 DIA HOLE CONDENSATE DRAIN 27 5/8" 4 3/4" ISOMETRIC -PACKAGED COOLING FLD = Furnished by Trane U.S. Inc. / Installed by Others Equipment Proposal Page 2 of 9 OG #1584 Tukwila WA AC -1 Kitchen Unit Dimensions - 3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: Al Qty: 1 Tag(s): AC -1 Kitchen March 1, 2018 CONTROL BOX SECTION ACCESS PANEL INDOOR TOP PANEL GAS CONNECTION (SEE NOTE 2) EVAPORATOR SECTION ACCESS PANEL CONDENSATE (SEE NOTE 1) 47 7/8" 53 3/4" HORIZONTAL AIR FLOW COMPRESSOR ACCESS PANEL POWER WIRE (SEE NOTE 3) PACKAGED GAS / ELECTRICAL OUTDOOR TOP PANEL ISOMETRIC VIEW 27 9/16" THROUGH THE BASE CONDENSATE 4 3/16" 33" SUPPLY 32 1/8" RETURN 17 1/2" PLAN VIEW UNIT 17 12" DIMENSION DRAWING CONDENSATE DRAIN 4 3/4" PACKAGED GAS / ELECTRICAL - CONDENSER FAN CONDENSER COIL CONDENSER COIL SIDE NOTES: 1. ALTERNATE CONDENSATE DRAIN CONNECTION 3/4" -14 NPT DIA. HOLE 2. 1/2" NPT GAS CONNECTION (80 mbh, 120 mbh) ; 3/4" NPT GAS CONNECTION (150mbh, 200mbh, 250mbh) 3. UNIT POWER WIRE 1 3/8" DIA. HOLE. 4. THRU -THE -BASE ELECTRICAL AND GAS IS NOT STANDARD ON ALL UNITS. 5. VERIFY WEIGHT, CONNECTION, AND ALL DIMENSION WITH INSTALLER DOCUMENTS BEFORE INSTALLATION COIL 621/4" SERVICE SIDE DIMENSION DRAWING HORIZONTAL AIR FLOW 162" FLD = Fumished by Trane U.S. Inc. / Installed by Equipment Proposal Page 3 of 9 Others OG #1584 Tukwila WA AC -1 Kitchen Unit Dimensions - 3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: Al Qty: 1 Tag(s): AC -1 Kitchen 'ELECTRICAL / GENERAL DATA March 1, 2018 'GENERAL (2)(4)46) Model: YHC120F Oversized Motor HEATING PERFORMANCE HEATING - GENERAL DATA Unit Operating Voltage: 187-253 MCA: N/A 'High Unit Primary Voltage: 208 MFS: N/A Heating Model: Unit Secondary Voltage 230 MCB: N/A Heating Input (BTU): 250,000/175,000 Unit Hertz: 60 Heating Output (BTU): 200,000/140,000 Unit Phase: 3 No. Burners: 5 No. Stages 2 EER Standard Motor Field Installed Oversized Motor 'Gas Inlet Pressure MCA: 46.1 MCA: N/A Natural Gas (Min/Max): 4.5/14 MFS: 60.0 MFS: N/A LP (Min/Max) 10.0/14.0 MCB: 60.0 MCB: N/A Gas Pipe Connection Size: 3/4" INDOOR MOTOR Standard Motor Oversized Motor Field Installed Oversized Motor Number '1 Number. N/A Number. N/A Horsepower. 2.75 Horsepower N/A Horsepower. N/A Motor Speed (RPM): — Motor Speed (RPM): N/A Motor Speed (RPM): N/A Phase 3 Phase N/A Phase N/A Full Load Amps: 8.5 - 8.5 Full Load Amps: N/A Full Load Amps: N/A Locked Rotor Amps: _ Locked Rotor Amps: N/A Locked Rotor Amps: N/A COMPRESSOR Circuit 1/2 OUTDOOR MOTOR Number: '2 Number: 1 Horsepower: 5.1/3.0 Horsepower. 0.75 Phase: 3 Motor Speed (RPM): 1100 Rated Load Amps: 19.6/10.4 Phase: 3 Locked Rotor Amps: 136.0/73.0 Fut Load Amps: 2.7 Locked Rotor Amps: 9.8 POWER EXHAUST ACCESSORY (3) FILTERS REFRIGERANT (2) (Field Installed Power Exhaust) Type R-410 Phase: N/A Type: Throwaway Horsepower: N/A Fumished: Yes Factory Charge Motor Speed (RPM): N/A Number 3 / 2 Circuit #1 7.1 Ib Fut Load Amps: N/A Recommended 20'X25"x2" Circuit#2 5.0 Ib Locked Rotor Amps: N/A 20"x30'x2" NOTES: 1. Maximum (HACR) Circuit Breaker sizing is for installations in the United States only. 2. Refrigerant charge is an approximate value. For a more precise value, see unit nameplate and service instructions. 3. Value does not include Power Exhaust Accessory. 4. Value includes oversized motor. 5. Value does not include Power Exhaust Accessory 6. EER is rated at AHRI conditions and in accordance with DOE test procedures. FLD = Fumished by Trane U.S. Inc. /Installed by Others Equipment Proposal Page 4 of 9 OG #1584 Tukwila WA AC -1 Kitchen Weight, Clearance & Rigging Diagram - 3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: Al Qty: 1 Tag(s): AC -1 Kitchen PACKAGED GAS / ELECTRICAL CORNER WEIGHT March 1, 2018 INSTALLED ACCESSORIES NET WEIGHT DATA ACCESSORY WEIGHTS ECONOMIZER 36.0 Ib MOTORIZED OUTSIDE AIR DAMPER MANUAL OUTSIDE AIR DAMPER BAROMETRIC RELIEF OVERSIZED MOTOR BELT DRIVE MOTOR POWER EXHAUST THROUGHT THE BASE ELECTRICAUGAS (FIOPS) 13.O Ib UNIT MOUNTED CIRCUIT BREAKER (FIOPS) 5.0 Ib UNIT MOUNTED DISCONNECT (FIOPS) POWERED CONVENIENCE OUTLET (FIOPS) 50.O Ib HINGED DOORS (FIOPS) 12.O lb HAIL GUARD 30.0 Ib SMOKE DETECTOR, SUPPLY / RETURN NOVAR CONTROL STAINLESS STEEL HEAT EXCHANGER REHEAT ROOF CURB BASIC UNIT WEIGHTS CORNER WEIGHTS CENTER OF GRAVITIY SHIPPING NET AO 356.0 Ib © 289.0 Ib (E) LENGHT (F) WIDTH 1453.OIb 1259.OIb BO 371.OIb OD 242.Olb 54" 27" 1. All weights are approxima e. 2. Weights for options that are not list refer to Installation guile. 3. The actual weight are listed on the unit nameplate. 4. Refer to unit nameplate and installation guide for weights before scheduling transportation and installation of unit. 5. The weight shown represents the typical unit operating weight for the configuration selected. Estimated at +/_ 10 % of the nameplate weight.. 6. Verify weight, connection, and all dimension with installer documents before installation. 7. Comer weights are given for information only. 8. Net/Shipping weight of optional accessories should be added to unit weight when ordering factory or field installed accessories. PACKAGED GAS / ELECTRICAL RIGGING AND CENTER OF GRAVITY FLD = Fumished by Trane U.S. Inc. /Installed by Equipment Proposal Page 5 of 9 Others OG #1584 Tukwila WA AC -1 Kitchen Weight, Clearance & Rigging Diagram - 3-10 Ton R410A PKGD Unitary GaslElectric Rooftop Item: Al Qty: 1 Tag(s): AC -1 Kitchen CLEARANCE 36" CLEARANCE 48" DOWNFLOW CLEARANCE 36" HORIZONTAL CLEARANCE 18" ROOF OPENING UNIT OUTLINE CLEARANCE 36" PACKAGED GAS / ELECTRIC CLEARANCE 46" 99 11/16" 46" March 1, 2018 CLEARANCE FROM TOP OF UNIT 72" 63 3/16" PACKAGED GAS / ELECTRIC DOWNFLOW TYPICAL ROOF OPENING FLD = Fumished by Trane U.S. Inc. / Installed by Others Equipment Proposal Page 6 of 9 t OG #1584 Tukwila WA AC -1 Kitchen March 1, 2018 TERMS AND CONDITIONS - COMMERCIAL EQUIPMENT "Company" shall mean Trane Canada ULC for sales in Canada and Trane U.S. Inc. for sales in the United States. 1. Acceptance. These terms and conditions are an integral part of Company's offer and form the basis of any agreement (the "Agreement") resulting from Company's proposal (the "Proposal") for the sale of the described commercial equipment and any ancillary services (the "Equipment"). COMPANY'S TERMS AND CONDITIONS ARE SUBJECT TO PERIODIC CHANGE OR AMENDMENT. The Proposal is subject to acceptance in writing by the party to whom this offer is made or an authorized agent ("Customer') delivered to Company within 30 days from the date of the Proposal. If Customer accepts the Proposal by placing an order, without the addition of any other terms and conditions of sale or any other modification, Customers order shall be deemed acceptance of the Proposal subject to Company's terms and conditions. If Customers order is expressly conditioned upon Company's acceptance or assent to terms and/or conditions other than those expressed herein, return of such order by Company with Company's terms and conditions attached or referenced serves as Company's notice of objection to Customer's terms and as Company's counter-offer to provide Equipment in accordance with the Proposal and the Company's terms and conditions. If Customer does not reject or object in writing to Company within 10 days, Company's counter-offer will be deemed accepted. Customers acceptance of the Equipment will in any event constitute an acceptance by Customer of Company's terms and conditions. This Agreement is subject to credit approval by Company. Upon disapproval of credit, Company may delay or suspend performance or, at its option, renegotiate prices and/or terms and conditions with Customer. If Company and Customer are unable to agree on such revisions, this Agreement shall be cancelled without any liability. 2. Title and Risk of Loss. All Equipment sales with destinations to Canada or the U.S. shall be made as follows: FOB Company's U.S. manufacturing facility or warehouse (full freight allowed). Title and risk of loss or damage to Equipment will pass to Customer upon tender of delivery of such to carrier at Company's U.S. manufacturing facility or warehouse. 3. Pricing and Taxes. Following acceptance without addition of any other terms and condition of sale or any other modification by Customer, the prices stated are firm provided that notification of release for immediate production and shipment is received at Company's factory not later than 3 months from order acceptance. If such release is received later than 3 months from order acceptance date, prices will be increased a straight 1% (not compounded) for each 1 month period (or part thereof) beyond the 3 month firm price period up to the date of receipt of such release. If such release is not received within 6 months after the date of order acceptance, the prices are subject to renegotiation or at Company's option, the order will be cancelled. Any delay in shipment caused by Customer's actions will subject prices to increase equal to the percentage increase in list prices during that period of delay and Company may charge Customer with incurred storage fees. In no event will prices be decreased. The price of Equipment does not include any present or future foreign, federal, state, or local property, license, privilege, sales, use, excise, value added, gross receipts or other like taxes or assessments. Such amounts will be itemized separately to Customer, who will make prompt payment to Company. Company wilt accept valid exemption documentation for such from Customer, if applicable. All prices include packaging in accordance with Company's standard procedures. Charges for special packaging, crating or packing are the responsibility of Customer. 4. Delivery and Delays. Delivery dates are approximate and not guaranteed. Company will use commercially reasonable efforts to deliver the Equipment on or before the estimated delivery date will notify Customer if the estimated delivery dates cannot be honored, and will deliver the Equipment and services as soon as practicable thereafter. In no event will Company be liable for any damages or expenses caused by delays in delivery. 5. Performance. Company shall be obligated to fumish only the Equipment described in the Proposal and in submittal data (if such data is issued in connection with the order). Company may rely on the acceptance of the Proposal, and in submittal data as acceptance of the suitability of the Equipment for the particular project or location. Unless specifically stated in the Proposal, compliance with any local building codes or other laws or regulations relating to specifications or the location, use or operation of the Equipment is the sole responsibility of Customer. If Equipment is tendered that does not fully comply with the provisions of this Agreement, and Equipment is rejected by Customer, Company will have the right to cure within a reasonable time after notice thereof by substituting a conforming tender whether or not the time for performance has passed. 6. Force Majeure. Company's duty to perform under this Agreement and the Equipment prices are contingent upon the non-occurrence of an Event of Force Majeure. If the Company shall be unable to carry out any material obligation under this Agreement due to an Event of Force Majeure, this Agreement shall at Company's election (i) remain in effect but Company's obligations shall be suspended until the uncontrollable event terminates or (ii) be terminated upon 10 days notice to Customer, in which event Customer shall pay Company for all parts of the Work fumished to the date of termination. An "Event of Force Majeure" shall mean any cause or event beyond the control of Company. Without limiting the foregoing, "Event of Force Majeure" includes: acts of God; acts of terrorism, war or the public enemy; flood; earthquake; tomado; storm; fire; civil disobedience; pandemic insurrections; riots; labor/labour disputes; labor/labour or material shortages; sabotage; restraint by court order or public authority (whether valid or invalid); and action or non -action by or inability to obtain or keep in force the necessary govemmental authorizations, permits, licenses, certificates or approvals if not caused by Company; and the requirements of any applicable govemment in any manner that diverts either the material or the finished product to the direct or indirect benefit of the govemment. 7. Limited Warranty. Company warrants the Equipment manufactured by Company for a period of the lesser of 12 months from initial start-up or 18 months from date of shipment, whichever is less, against failure due to defects in material and manufacture and that it has the capacities and ratings set forth in Company's catalogs and bulletins ('Warranty"). Equipment manufactured by. Company that includes required start-up and sold in North America will not be warranted by Company unless Company performs the Equipment startup. Exclusions from this Warranty include damage or failure arising from: wear and tear; corrosion, erosion, deterioration; modifications made by others to the Equipment; repairs or alterations by a party other than Company that adversely affects the stability or reliability of the Equipment; vandalism; neglect; accident; adverse weather or environmental conditions; abuse or improper use; improper installation; commissioning by a party other than Company; unusual physical or electrical or mechanical stress; operation with any accessory, equipment or part not specifically approved by Company; refrigerant not supplied by Company; and/or lack of proper maintenance as recommended by Company. Company shall not be obligated to pay for the cost of lost refrigerant or lost product. Company's obligations and liabilities under this Warranty are limited to furnishing replacement equipment or parts, at its option, FCA (Incoterms 2000) factory or warehouse (f.o.b. factory or warehouse for US domestic purposes) at Company -designated shipping point, freight -allowed to Company's warranty agent's stock location, for all non -conforming Company -manufactured Equipment (which have been retumed by Customer to Company. Retums must have prior written approval by Company and are subject to restocking charge where applicable. Equipment, material and/or parts that are not manufactured by Company are not warranted by Company and have such warranties as may be extended by the respective manufacturer. COMPANY MAKES NO REPRESENTATION OR WARRANTY, EXPRESS OR IMPLIED, REGARDING PREVENTION OF MOLD/MOULD, FUNGUS, BACTERIA, MICROBIAL GROWTH, OR ANY OTHER CONTAMINATES. No warranty liability whatsoever shall attach to Company until Customer's complete order has been paid for in full and Company's liability under this Warranty shall be limited to the purchase price of the Equipment shown to be defective. Additional warranty protection is available on an extra -cost basis and must be in wilting and agreed to by an authorized signatory of the Company. EXCEPT FOR COMPANY'S WARRANTY EXPRESSLY SET FORTH HEREIN, COMPANY DOES NOT MAKE, AND HEREBY EXPRESSLY DISCLAIMS, ANY WARRANTIES, EXPRESS OR IMPLIED CONCERNING ITS PRODUCTS, EQUIPMENT OR SERVICES, INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF DESIGN, MERCHANTABILITY OR OF FITNESS FOR A PARTICULAR PURPOSE, OR OTHERS THAT ARE ALLEGED TO ARISE FROM COURSE OF DEALING OR TRADE. 8. Indemnity. To the fullest extent permitted by law, Company and Customer shall indemnify, defend and hold harmless each other from any and all claims, actions, costs, expenses, damages and liabilities, including reasonable attorneys' fees, resulting from death or bodily injury or damage to real or personal property, to the extent caused by the negligence or misconduct of their respective employees or other authorized agents in connection with their activities within the scope of this Agreement. Neither party shall indemnify the other against claims, damages, expenses or liabilities to the extent attributable to the acts or omissions of the other party. If the parties are both at fault, the obligation to indemnify shall be proportional to their relative fault. The duty to indemnify will continue in full force and effect, notwithstanding the expiration or early termination hereof, with respect to any claims based on facts or conditions that occurred prior to expiration or termination. FLD = Fumished by Trane U.S. Inc. / Installed by Others Equipment Proposal Page 7 of 9 OG #1584 Tukwila WA AC -1 Kitchen March 1, 2018 9. Insurance. Upon request, Company will fumish evidence of its standard insurance coverage. If Customer has requested to be named as an additional insured under Company's insurance policy, Company will do so but only subject to Company's manuscript additional insured endorsement under its primary Commercial General Liability policies. In no event does Company waive any rights of subrogation. 10. Customer Breach. Each of the following events or conditions shall constitute a breach by Customer and shall give Company the right, without an election of remedies, to terminate this Agreement, require payment prior to shipping, or suspend performance by delivery of written notice: (1) Any failure by Customer to pay amounts when due; or (2) any general assignment by Customer for the benefit of its creditors, or if Customer becomes bankrupt or insolvent or takes the benefit of any statute for bankrupt or insolvent debtors, or makes or proposes to make any proposal or arrangement with creditors, or if any steps are taken for the winding up or other termination of Customer or the liquidation of its assets, or if a trustee, receiver, or similar person is appointed over any of the assets or interests of Customer, (3) Any representation or warranty fumished by Customer in connection with this Agreement is false or misleading in any material respect when made; or (4) Any failure by Customer to perform or comply with any material provision of this Agreement. Customer shall be liable to the Company for all Equipment fumished and all damages sustained by Company (including lost profit and overhead). 11. Limitation of Liability. NOTWITHSTANDING ANYTHING TO THE CONTRARY, IN NO EVENT SHALL COMPANY BE LIABLE FOR ANY SPECIAL, INCIDENTAL, INDIRECT CONSEQUENTIAL, OR PUNITIVE OR EXEMPLARY DAMAGES (INCLUDING WITHOUT LIMITATION REFRIGERANT LOSS, BUSINESS INTERRUPTION, LOST DATA, LOST REVENUE, LOST PROFITS) EVEN IF A PARTY HAS BEEN ADVISED OF SUCH POSSIBLE DAMAGES OR IF SAME WERE REASONABLY FORESEEABLE AND REGARDLESS OF WHETHER THE CAUSE OF ACTION IS FRAMED IN CONTRACT, NEGLIGENCE, ANY OTHER TORT, WARRANTY, STRICT LIABILITY, OR PRODUCT LIABILITY). In no event will Company's liability in connection with the provision of products or services or otherwise under this Agreement exceed the entire amount paid to Company by Customer under this Agreement. 12. Nuclear Liability. In the event that the Equipment sold hereunder is to be used in a nuclear facility, Customer will, prior to such use, arrange for insurance or govemmental indemnity protecting Company against all liability and hereby releases and agrees to indemnify Company and its suppliers for any nuclear damage, including loss of use, in any manner arising out of a nuclear incident, whether alleged to be due, in whole or in part to the negligence or otherwise of Company or its suppliers. 13. Intellectual Property; Patent Indemnity. Company retains all ownership, license and other rights to all patents, trademarks, copyrights, trade secrets and other intellectual property rights related to the Equipment, and, except for the right to use the Equipment sold, Customer obtains no rights to use any such intellectual property. Company agrees to defend any suit or proceeding brought against Customer so far as such suit or proceeding is solely based upon a claim that the use of the Equipment provided by Company constitutes infringement of any patent of the United States of America, provided Company is promptly notified in writing and given authority, information and assistance for defense of same. Company will, at its option, procure for Customer the right to continue to use said Equipment, or modify it so that it becomes non -infringing, or replace same with non -infringing Equipment, or to remove said Equipment and to refund the purchase price. The foregoing will not be construed to include any Agreement by Company to accept any liability whatsoever in respect to patents for inventions including more than the Equipment fumished hereunder, or in respect of patents for methods and processes to be carried out with the aid of said Equipment. The provision of Equipment by Company does not convey any license, by implication, estoppel, or otherwise, under patent claims covering combinations of said Equipment with other devices or elements. The foregoing states the entire liability of Company with regard to patent infringement. Notwithstanding the provisions of this paragraph, Customer will hold Company harmless against any expense or loss resulting from infringement of patents or trademarks arising from compliance with Customer's designs or specifications or instructions. 14. Cancellation. Equipment is specially manufactured in response to orders. An order placed with and accepted by Company cannot be delayed, canceled, suspended, or extended except with Company's written consent and upon written terms accepted by Company that will reimburse Company for and indemnify Company against loss and provide Company with a reasonable profit for its materials, time, labor, services, use of facilities and otherwise. Customer will be obligated to accept any Equipment shipped, tendered for delivery or delivered by Company pursuant to the order prior to any agreed delay, cancellation, suspension or extension of the order. Any attempt by Customer to unilaterally revoke, delay or suspend acceptance for any reason whatever after it has agreed to delivery of or accepted any shipment shall. constitute a breach of this Agreement. For purposes of this paragraph, acceptance occurs by any waiver of inspection, use or possession of Equipment, payment of the invoice, or any indication of exclusive control exercised by Customer. 15. Invoicing and Payment. Equipment shall be invoiced to Customer upon tender of delivery thereof to the carrier. Customer shall pay Company's invoices within net 30 days of shipment date. Company reserves the right to add to any account outstanding for more than 30 days a service charge equal to the lesser of the maximum allowable legal interest rate or 1.5% of the principal amount due at the end of each month. Customer shall pay all costs (including attomeys' fees) incurred by Company in attempting to collect amounts due and otherwise enforcing these terms and conditions. If requested, Company will provide appropriate lien waivers upon receipt of payment. Company may at any time decline to ship, make delivery or perform work except upon receipt of cash payment, letter of credit, or security, or upon other terms and conditions satisfactory to Company. Customer agrees that, unless Customer makes payment in advance, Company will have a purchase money security interest in all Equipment to secure payment in full of all amounts due Company and its order for the Equipment, together with these terms and conditions, form a security agreement (as defined by the UCC in the United States and as defined in the Personal Property Security Act in Canada). Customer shall keep the Equipment free of all taxes and encumbrances, shall not remove the Equipment from its original installation point and shall not assign or transfer any interest in the Equipment until all payments due Company have been made. The purchase money security interest granted herein attaches upon Company's acceptance of Customer's order and on receipt of the Equipment described in the accepted Proposal but prior to its installation. The parties have no agreement to postpone the time for attachment unless specifically noted in writing on the accepted order. Customer will have no rights of set off against any amounts, which become payable to Company under this Agreement or otherwise. 16. Claims. Company will consider claims for concealed shortages in shipments or rejections due to failure to conform to an order only if such claims or rejections are made in writing within 15 days of delivery and are accompanied by the packing list and, if applicable, the reasons in detail why the Equipment does not conform to Customer's order. Upon receiving authorization and shipping instructions from authorized personnel of Company, Customer may retum rejected Equipment, transportation charges prepaid, for replacement. Company may charge Customer any costs resulting from the testing, handling, and disposition of any Equipment returned by Customer which are not found by Company to be nonconforming. All Equipment damaged during shipment and all claims relating thereto must be made with the freight carrier in accordance with such carrier's policies and procedures. Claims for Equipment damaged during shipment are not covered under the warranty provision stated herein. 17. Export Laws. The obligation of Company to supply Equipment under this Agreement is subject to the ability of Company to supply such items consistent with applicable laws and regulations of the United States and other governments. Company reserves the right to refuse to enter into or perform any order, and to cancel any order, under this Agreement if Company in its sole discretion determines that performance of the transaction to which such order relates would violate any such applicable law or regulation. Customer will pay all handling and other similar costs from Company's factories including the costs of freight, insurance, export clearances, import duties and taxes. Customer will be "exporter of record" with respect to any export from the United States of America and will perform all compliance and logistics functions in connection therewith and will also comply with all applicable laws, rules and regulations. Customer understands that Company and/or the Equipment are subject to laws and regulations of the United States of America which may require licensing or authorization for and/or prohibit export, re-export or diversion of Company's Equipment to certain countries, and agrees it will not knowingly assist or participate in any such diversion or other violation of applicable United States of America laws and regulations. Customer agrees to hold harmless and indemnify Company for any damages resulting to Customer or Company from a breach of this paragraph by Customer. 18. General. Except as. provided below, to the maximum extent provided by law, this Agreement is made and shall be interpreted and enforced in accordance with the laws of the state of New York for Equipment shipped to a U.S. location and the laws of the province to which Equipment is FLD = Fumished by Trane U.S. Inc. /Installed by Others Equipment Proposal Page 8 of 9 .o OG #1584 Tukwila WA AC -1 Kitchen March 1, 2018 shipped within Canada, without regard to its conflict of law principles that might otherwise call for the application of a different state's or province's law, and not including the United Nations Convention on Contracts for the International Sale of Goods. Any action or suit arising out of or related to this Agreement must be commenced within one year after the cause of action has accrued. To the extent the Equipment is being used at a site owned and/or operated by any agency of the Federal Govemment, determination of any substantive issue of law shall be according to the Federal common law of Govemment contracts as enunciated and applied by Federal judicial bodies and boards of contract appeals of the Federal Govemment. This Agreement contains all of the agreements, representations and understandings of the parties and supersedes all previous understandings, commitments or agreements, oral or written, related to the subject matter hereof. This Agreement may not be amended, modified or terminated except by a writing signed by the parties hereto. No documents shall be incorporated herein by reference except to the extent Company is a signatory thereon. If any term or condition of this Agreement is invalid, illegal or incapable of being enforced by any rule of law, all other terms and conditions of this Agreement will nevertheless remain in full force and effect as long as the economic or legal substance of the transaction contemplated hereby is not affected in a manner adverse to any party hereto. Customer may not assign, transfer, or convey this Agreement, or any part hereof, or its right, title or interest herein, without the written consent of the Company. Subject to the foregoing, this Agreement shall be binding upon and inure to the benefit of Customer's permitted successors and assigns. This Agreement may be executed in several counterparts, each of which when executed shall be deemed to be an original, but all together shall constitute but one and the same Agreement. A fully executed facsimile copy hereof or the several counterparts shall suffice as an original. 19. Equal Employment Opportunity/Affirmative Action Clause. Company is a federal contractor that complies fully with Executive Order 11246, as amended, and the applicable regulations contained in 41 C.F.R. Parts 60-1 through 60-60, 29 U.S.C. Section 793 and the applicable regulations contained in 41 C.F.R. Part 60-741; and 38 U.S.C. Section 4212 and the applicable regulations contained in 41 C.F.R. Part 60-250 Executive Order 13496 and Section 29 CFR 471, appendix A to subpart A, regarding the notice of employee rights in the United States and with Canadian Charter of Rights and Freedoms Schedule B to the Canada Act 1982 (U.K.) 1982, c. 11 and applicable Provincial Human Rights Codes and employment law in Canada. 20. U.S. Government Work. The following provision applies only to direct sales by Company to the US Government. The Parties acknowledge that Equipment ordered and delivered under this Agreement are Commercial Items as defined under Part 12 of the Federal Acquisition Regulation (FAR). In particular, Company agrees to be bound only by those Federal contracting clauses that apply to "commercial" suppliers and that are contained in FAR 52.212-5(e)(1). The following provision applies only to indirect sales by Company to the US Government. As a Commercial Item Subcontractor, Company accepts only the following mandatory flow down provisions: 52.219-8; 52.222-26; 52.222-35; 52.222-36; 52.222-39; 52.247-64. If the sale of the Equipment is in connection with a U.S. Govemment contract, Customer certifies that it has provided and will provide current, accurate, and complete information, representations and certifications to all govemment officials, including but not limited to the contracting officer and officials of the Small Business Administration, on all matters related to the prime contract, including but not limited to all aspects of its ownership, eligibility, and performance. Anything herein notwithstanding, Company will have no obligations to Customer unless and until Customer provides Company with a true, correct and complete executed copy of the prime contract. Upon request, Customer will provide copies to Company of all requested written communications with any government official related to the prime contract prior to or concurrent with the execution thereof, including but not limited to any communications related to Customer's ownership, eligibility or performance of the prime contract. Customer will obtain written authorization and approval from Company prior to providing any govemment official any information about Company's performance of the work that is the subject of the Proposal or this Agreement, other than the Proposal or this Agreement. 21. Limited Waiver of Sovereign Immunity. If Customer is an Indian tribe (in the U.S.) or a First Nation or Band Council (in Canada), Customer, whether acting in its capacity as a govemment, govemmental entity, a duly organized corporate entity or otherwise, for itself and for its agents, successors, and assigns: (1) hereby provides this limited waiver of its sovereign immunity as to any damages, claims, lawsuit, or cause of action (herein "Action") brought against Customer by Company and arising or alleged to arise out of the fumishing by Company of any product or service under this Agreement, whether such Action is based in contract, tort, strict liability, civil liability or any other legal theory; (2) agrees that jurisdiction and venue for any such Action shall be proper and valid (a) if Customer is in the U.S., in any state or United States court located in the state in which Company is performing this Agreement or (b) if Customer is in Canada, in the superior court of the province or territory in which the work was performed; (3) expressly consents to such Action, and waives any objection to jurisdiction or venue; (4) waives any requirement of exhaustion of tribal court or administrative remedies for any Action arising out of or related to this Agreement; and (5) expressly acknowledges and agrees that Company is not subject to the jurisdiction of Customer's tribal court or any similar tribal forum, that Customer will not bring any action against Company in tribal court, and that Customer will not avail itself of any ruling or direction of the tribal court permitting or directing it to suspend its payment or other obligations under this Agreement. The individual signing on behalf of Customer warrants and represents that such individual is duly authorized to provide this waiver and enter into this Agreement and that this Agreement constitutes the valid and legally binding obligation of Customer, enforceable in accordance with its terms. 1-26.130-4 (0614) Supersedes 1-26.130-4(0214) FLD = Fumished by Trane U.S. Inc. /Installed by Others Equipment Proposal Page 9 of 9 5/2/2019 City of Tukwila Department of Community Development ALEX SOKIRKIN 11227217 ST CTE GRAHAM, WA 98338 RE: Permit No. M18-0046 OLIVE GARDEN Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 6/18/2019. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 6/18/2019, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. ely, Kandace Nichols Permit Technician File No: M18-0046 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 =PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M18-0046 DATE: 04/09/18 PROJECT NAME: OLIVE GARDEN SITE ADDRESS: 310 STRANDER BLVD X Original Plan Submittal Response to Correction Letter # Revision # Revision # before Permit Issued after Permit Issued DEPARTMENTS: AWC)-H 1S Building Division III Public Works h -INA Fire Prevention Structural Planning Division ❑ Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 04/10/18 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 05/08/18 Approved ❑ Approved with Conditions ❑ Corrections Required ❑ Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: 12/18/2013 PACIFIC REFRIGERATION UNLP-'D Hoene Ispanol Contact. Safety & Health Claims & Insurance 0 Washington State Department of Labor & Industries Search L&I Page 1 of 2 A -Z Index Help My L&I Workplace Rights Trades & Licensing PACIFIC REFRIGERATION UNLMTD Owner or tradesperson Principals Sokirkin, Aleksey P, PARTNER/MEMBER Doing business as PACIFIC REFRIGERATION UNLMTD WA UBI No. 603 252 618 PO Box 1557 TACOMA, WA 98401 253-292-8728 PIERCE County Business type Limited Liability Company License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. PACIFRU831J0 Effective — expiration 04120/2017— 04/20/2019 Active. Meets current requirements. Bond Ohio Cas Ins Co $12,000.00 Bond account no. 32S383356 Received by L&I Effective date 04/20/2017 04/17/2017 Expiration date Until Canceled Insurance Sentinel Insurance Co LTD Policy no. 01 SBARG6282 $1,000,000.00 Received by L&I Effective date 10/02/2017 10/17/2017 Expiration date 10/17/2018 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. 1 1 https://secure.lni.wa.gov/verify/Detail.aspx?UBI=603252618&LIC=PACIFRU831 JO&SAW= 5/2/2018 Help us improve PACIFIC REFRIGERATION UNL}TD IWorkers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID 620,799-00 Account is current. Doing business as PACIFIC REFRIGERATION UNLIMITE Estimated workers reported Quarter 1 of Year 2018 "11 to 20 Workers" L&I account contact T4 1 ALISON WOODWARD (360)902-4629 - Email: WOAL235@Ini.wa.gov Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 12/29/2017 Inspection no. 317947066 Location 1100 N Miller St Wenatchee, WA 98801-1541 Violations Page 2 of 2 Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington, Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=603252618&LIC=PACIFRU831 JO&SAW= 5/2/2018