HomeMy WebLinkAboutPermit M18-0047 - SEBCO WAREHOUSE - HEATERS, EXHAUST FANS, WALL HEATER AND NATURAL GAS PIPINGSEBCO WAREHOUSE 11060 TUKWILA INTL BLVD COMPLEX MI 8-0047 Parcel No: Address: 11 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 0423049014 Permit Number: M18-0047 11060 TUKWILA INTL BLVD COMPLEX Project Name: SEBCO WAREHOUSE Issue Date: 5/11/2018 Permit Expires On: 11/7/2018 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: SEBCO INC 4020 E MADISON ST #320 , SEATTLE, WA, 98112 HEATH HAMBLEN 4102 B PLACE NW , AUBURN, WA, 98001 UNIVERSAL REFRIGERATION INC (CONST) PO BOX 614 , AUBURN, WA, 98071- 0614 UNIVERI159RF Phone: (253) 939-5501 Phone: (253) 939-5501 Expiration Date: 4/1/2020 DESCRIPTION OF WORK: HVACR MECHANICAL, INSTALL (4) REZNOR UNIT HEATERS, (3) ROOF MOUNTED EXHAUST FANS AND (1) ELECTRIC WALL HEATER. NATURAL GAS PIPING. Valuation of Work: $31,720.00 Type of Work: NEW Fuel type: GAS Fees Collected: $623.91 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: TUKWILA Sewer District: VALLEY VIEW Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Permit Center Authorized Signature: Date: J I ��U / I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: A, O\ C,r\ W 115c,t•-\ Date: —.5.:,7%//4"c This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: Readily accessible access to roof mounted equipment is required. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: ***MECHANICAL PERMIT CONDITIONS*** 10: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 11: Manufacturers installation instructions shall be available on the job site at the time of inspection. 17: TO SCHEDULE ALL FIRE INSPECTIONS CALL 206-575-4407. 14: Sprinkler coverage around unit heaters needs to comply with section 8.3.2.5 and figure 8.3.2.5 of NFPA 13 (2016 edition). 12: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2436). 13: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) � tJ 15: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 16: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1400 FIRE FINAL 1800 MECHANICAL FINAL 0701 ROUGH -IN MECHANICAL / \ CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov / \ Mechanical Permit No. IV 16 Project No. Date Application Accepted: Date Application Expires: tQ (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address: 1tC-Tu14,S,1p biz.nAa-I ON PA �,lvt) . Tenant Name: SEE,CO �A( 4.OUSk, PROPERTY OWNER Name Heath Hamblen ryan Galvin Chuck Stephen Name: 5EzL0 !...0LL. Phone: (253) 939-5501 Fax: (253) 735-3432 Contr Reg No.: UNIVERI 159RF Exp Date: 04/01/2019 Address: 40Z0 (r. ADtSr.]rJ -. `' 2 A 7`%.b City: 5ka, Email: �lr► State: aA Zipii4 22 CONTACT PERSON — person receiving all project communicating Name Heath Hamblen ryan Galvin Chuck Stephen Addres . 192 Phone: (253) 939-5501 Fax: (253) 735-3432 Contr Reg No.: UNIVERI 159RF Exp Date: 04/01/2019 City: Aubu- State: WA Zip: 98001 Phone: (253) 939-5501 Fax: (253) 735-3432 Email: �lr► @universalrefrig.com King Co Assessor's Tax No.: 04 23o4 - 9014 Suite Number: Floor: New Tenant: 121 Yes ❑..No MECHANICAL CONTRACTOR INFORMATION Company Name: Universal Refrigeration Address: 4102 B PL NW City: Auburn State: WA Zip: 98001 Phone: (253) 939-5501 Fax: (253) 735-3432 Contr Reg No.: UNIVERI 159RF Exp Date: 04/01/2019 Tukwila Business License No.: BUS -0993124 Valuation of project (contractor's bid price): $ 31112.O . Describe the scope of work in detail: ` 1 HVACR Mechanical, install (4 )2,� rsors. U -(l.$ ,('3V. . w 'rb '» ) o t t7.�Av4 si.bs Adt:.(1' ttultoc. (AAA 1J4\-uno.1 43,5 Use: Residential: New ❑ Replacement ❑ Commercial: New [V] Replacement ❑ Fuel Type: Electric ❑ Gas RI Other: H:Wpplications\Fomvs-Applications On Line \2016 Applications\Mechanical Permit Application Revised 1-4-16.docx Revised: January 2016 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: ' r • 4� Unit Type ;Qty • , . Air handling unit , Furnace <100k btu Industrial Furnace >100k btu 3 Floor furnace 57 dB(A) Suspended/wall/floor mounted heater y Appliance vent I Repair or addition to heat/refrig/cooling system 65 dB(A) Air handling unit 60 dB(A) <10,000 cfm 65 dB(A) Unit Type Qty Air handling unit Residential, Nighttime >10,000 cfm Industrial Evaporator cooler 3 Ventilation fan connected to single duct 57 dB(A) Ventilation system Commercial Hood and duct I Incinerator — domestic 65 dB(A) Incinerator — comm/industrial 60 dB(A) Unit Type Qty Fire damper Residential, Nighttime Diffuser Industrial Thermostat 3 Wood/gas stove 57 dB(A) Emergency generator Commercial Other mechanical equipment I 60 dB(A) 65 dB(A) Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential 'zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-10PM,Monday through Friday and 8AM-10PM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: • Warning devices; • Construction and property maintenance during the daytime hours (7am-I Opm); • Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY TFIE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Date: 14 q' 18 Print Name: Jerry Aeschlimann or Aidan Wilson Day Telephone: (253) 939-5501 Mailing Address: 4102 B PL NW AUBURN WA 98001 CityState Zip H:Wpplications\Forms-Applications On Line \2016 Applications'Mechanical Permit Application Revised I-4-16.docx Revised: January 2016 bh Page 2 of 2 Cash Register, Receipl City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $841.24 EL18-0313 Address: 11060 TUKWILA INTL BLVD COMPLEX Apn: 0423049014 $88.05 ELECTRICAL $83.86 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $83.86 TECHNOLOGY FEE $4.19 TECHNOLOGY FEE R000.322.900.04.00 0.00 $4.19 M18-0047 Address: 11060 TUKWILA INTL BLVD COMPLEX Apn: 0423049014 $623.91 MECHANICAL $599.91 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $446.78 PLAN CHECK FEE R000.322.102.00.00 0.00 $119.98 TECHNOLOGY FEE $24.00 TECHNOLOGY FEE R000.322.900.04.00 0.00 $24.00 PG18-0054 Address: 11060 TUKWILA INTL BLVD COMPLEX Apn: 0423049014 $129.28 GAS $124.31 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $66.30 PLAN CHECK FEE R000.322.103.00.00 0.00 $24.86 TECHNOLOGY FEE $4.97 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R14189 R000.322.900.04.00 0.00 $4.97 '" $841.24 Date Paid: Monday, April 09, 2018 Paid By: UNIVERSAL REFRIGERATION INC (E Pay Method: CHECK 53222 Printed: Monday, April 09, 2018 1:14 PM 1 of 1 SYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION /l'4 a2`7 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Projecct/t:j��j Type of Inspection: om , Address: 11 OW </V.,4,3 i *- ry-)1 £t Date Called: -4'c Special Instructions: Date Wanted: "2-^21 `t� a:m. m. Requester: Phone No: 7,00 V /4/73 pproved per applicable codes. LJ Corrections required prior to approval. COMMENTS: o`_jt/�-�C� tO Inspector: Date: % insp ction/. fee L REINSPECTION FE REQUIRED. Prior to nextmust be 60 - paid paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 1 -CO l 7 Project: �' i- s / % x o W e/'io1ue T e of Inspection: � ,4t) e t 1 rArs,` Address: 7-1-4A //060 /1-4A h'L.4 Date led: Date Special Instructions: ,,e, a. Date Wanted: m;� /0 r 2.9 -2,0/g p.m. Requester: fle J N Phone No: 7-s3 -932 -550/ ❑ Approved per applicable codes. COMMENTS: orrections required prior to approval. 11/4ed /94-04;! o/ic Inspector: cco Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. UNIVERSAL REFRIGERATION HEATING & AIR (onronIHG Heating Air Conditioning Refrigeration Contractors Licit UNIVERI*159RF Oregon Lic# 160248 SEBCO Warehouse 11060 Tukwila International Blvd. Tukwila, WA 98168 HVAC Equipment Submittals To: Poe Construction Company, Inc. From: Universal Refrigeration, Inc Heath Hamblen REVIEWED FOR CODE COMPLIANCE APPROVED MAY 01 2018 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA APR 1392018 PERMIT CENTER Ml4TYti P.O. Box 614 • 4102 "B" PL NW • Auburn, WA 98071 Seattle: (253) 839-2126 • Tacoma: (253) 922-3141 • Auburn: (253) 939-5501 • Fax: (253) 735-3432 Table of Contents 1. Reznor Unit Heater: UH -1 thru UH -4 2. Exhaust Fans: EF -1 thru EF -3 3. Electric Wall Heater: EWH-1 1. Reznor Unit Heaters: UH -1 thru UH -4 REZNOR® Model UDAP DESCRIPTION STANDARD FEATURES OPTIONAL FEATURES - FACTORY INSTALLED Form RZ-C-UH (Version H) Page 8 Page Number Power Vented, Low Static Axial Fan Unit Heaters for Residential and Commercial/Industrial Use Sizes 30-125 approved for utility applications such as residential garages under CSA International Requirement 10.96 - U.S. and CR96-0005 - Canada CSA 2.6b ANSI Z83.8b of Reznor® V3 Series Model UDAP gas-fired unit heaters are available in 14 sizes ranging from 30,000 to 400,000 BTUH gas input. Sizes 30-125 are approved for residential application. All sizes are approved for commercial/ industrial installations. Model UDAP heaters are designed for 82-83% thermal efficiency and are approved for installation in the United States and Canada by the Canadian Standards Association (CSA). Reznor V3 Series unit heaters have a refreshing new appearance with a glossy white cabinet finish and less visible hardware. Each size cabinet is easily suspended from either 2 or 4 suspension points. Or, an optional hanger kit for Sizes 30-125 allows for ceiling mounting. The low voltage terminal strip on the outside of the cabinet makes connecting control wiring easy with no panels to remove. The addition of a "G" terminal to the strip, along with the new design of the circuit board, allows for fan only operation (without adding relays). All units have a factory installed gas line nipple to the exterior of the cabinet for easy gas service connection. The preeminent new intemal feature is the TcoRE2 t8 heat exchanger and single bumer combustion system. Other standard features include a single -stage gas valve, multi -try direct spark ignition with 100% lockout, pres- sure switch to verify vent flow, resiliently isolated venter motor, venter wheel with improved housing, resiliently isolated axial fan and motor assembly, and a high temperature limit control. Sizes 30-125 also include a flame rollout safety switch. Operation is controlled through an integrated circuit board. The circuit board monitors heater operation and has LED diagnostic indicator lights to identify abnormalities in control functions. The V3 Series unit heaters are designed to provide all the features you expect in a Reznor heater plus im- proved efficiency, easier installation, and a new look — both inside and out. Look for the unique white unit with no visible front and bottom hardware, deep red louvers, black side handle, and angled corner to know you have a genuine Reznor unit by Thomas & Betts. • Sizes 30-125 certified for residential heating application • Sizes 30-400 certified for commercial/industrial heating application • 82-83% Thermal efficient — TOP in its class! • 50-60°F Rise range • TcoRE2® titanium stabilized aluminized steel heat exchanger • Patented** TcoRE2® single bumer combustion system including a one-piece bumer assembly • 115/1/60 Supply voltage • 115 Volt open fan motor with internal overload protection • Transformer for 24 -volt controls • Integrated circuit board with diagnostic indicator lights • Multi -try direct spark ignition with 100% lockout • Fan relay (included on the circuit board) • Single -stage natural gas valve (field adjustable for operation to 9,000 ft. elevation) • Vibration/noise isolated fan and venter motors — designed for low noise operation • 2 -pt and 4 -pt Suspension — standard on all sizes • Extemal terminal strip for 24 -volt wiring • Extemal gas connection • Full fan guard — engineered for safety • Improved cabinet design with less visible hardware and a NEW Reznor appearance • Single -stage, propane gas valve (field adjustable for operation to 9,000 ft. elevation) • Two-stage natural gas or propane gas valve - Sizes 60-400 • 409 or 316 Stainless steel heat exchangers • 208 or 230 Single phase voltage • Totally enclosed fan motor (Sizes 30-250, 115V only) • Common venting with other gravity vented Category I appliance(s) (Sizes 30-100) U.S. Patent No. 6,889,686 OPTIONAL FEATURES - FIELD INSTALLED TECHNICAL DATA Model UDAP • Vent cap • Thermostat • Thermostat guard with locking cover • Vertical louvers - new design • Downtum nozzle kits - new design • Gas conversion kits (natural and propane) • Master/Slave controls for zoning up to six units • Ceiling suspension kit - Sizes 30-125 • Hanger kits for 1" pipe • Stepdown transformer (for 230/3 and 460/3 supply voltage) • Manual shutoff valves Page Number of Size 30 45 60 76 100 125 150 175 200 225 250 300 350 400 Input Heating Capacity BTUH 30,000 45,000 60,000 75,000 105,000 120,000 150,000 175,000 200,000 225,000 250,000 300,000 350,000 400,000 kW/h 8.8 13.2 17.6 22.0 30.8 35.2 43.9 51.2 58.6 65.9 73.2 87.8 102.5 117.1 Thermal Efficiency (%) 82 83 83 83 83 83 83 83 83 83 83 83 83 83 Output Heating CapacityA BTUH 24,600 37,350 49,800 62,250 87,150 99,600 124,500 145,250 166,000 186,750 207,500 249,000 290,500 332,000 kW/h 7.2 11.0 14.6 18.3 25.6 29.2 36.4 42.5 48.6 54.7 60.8 72.9 85.1 97.2 Gas Connection (inches) a Natural 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 3/4 3/4 3/4 3/4 3/4 Propane 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 3/4 3/4 3/4 3/4 3/4 Vent Connection Size ° (inches diameter) 4 4 4 4 4 4 5 5 5 5 5 6 6 6 Control Amps (24 volt) 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 Full Load Amps (115 volt) 1.9 2.4 2.4 3.3 3.9 5.1 3.8 3.8 4.6 7.5 7.5 11.0 11.0 11.0 MaximumOver Current Protection 115\/ ° 15 15 15 15 15 15 15 15 15 15 15 20 20 20 Normal Power Consumption (watts) 109 155 155 217 276 354 392 392 491 747 747 1086 1086 1086 Discharge Air Temperature Rise CF) 50 55 60 60 60 60 60 60 60 60 60 60 60 60 Air Volume CFM 456 629 769 961 1345 1537 1921 2242 2562 2882 3202 3843 4483 5123 M3/minute 12.9 17.8 21.8 27.5 36.7 45.9 54.4 63.5 72.5 81.6 90.7 108.8 126.9 145.1 Discharge Air Opening Area ft2 0.96 0.96 1.25 1.25 2.01 2.01 2.56 2.56 2.56 3.51 3.51 4.79 4.79 4.79 M2 0.09 0.09 0.12 0.12 0.19 0.19 0.24 0.24 0.24 0.33 0.33 0.45 0.45 0.45 Output Velocity FPM 475 656 616 770 668 763 752 877 1003 820 911 802 936 1069 M/minute 145 200 188 238 196 245 229 267 306 250 278 244 285 326 Fan Motor HP E Open 0.02 0.03 0.03 0.06 1/30 1/20 1/6 1/6 1/6 1/4 1/4 1/2 1/2 1/2 Enclosed 0.06 0.06 0.06 0.06 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/2 1/2 1/2 Fan Motor RPM 1550 1550 1550 1550 1050 1050 1050 1050 1050 1050 1050 1050 1050 1050 Fan Diameter (inches) 10 10 12 12 16 16 18 18 18 20 20 24 24 24 Sound Level dBs ft 40 40 40 49 54 55 51 52 53 56 56 59 61 62 Approximate Net Weight lbs 54 59 67 72 96 101 172 187 187 203 215 269 294 306 kg 24 27 30 33 44 46 78 85 85 92 98 122 133 139 Approximate Ship Weight lbs 61 66 74 79 118 123 204 219 219 245 257 321 346 358 kg 27 30 33 36 54 56 93 100 100 111 117 146 157 163 CSA rating for altitudes to 2000 ft. ° Size shown is for gas connection to a single stage gas valve, not supply line size. Smaller or larger vent pipe diameters may be allowed; refer to the Venting Installation Manual, Form I -V -PV. If vent diameter is different from vent connection, reducer/enlargers will be field -required. ° MODP = 2.25 x (largest motor FLA) + smallest motor FLA. Answer is rounded to the nearest commercially available circuit breaker. .All other information in this table is based on a heater equipped with a standard 115 volt open fan motor. Form RZ-C-UH (Version H) Page 9 DIMENSIONS Model UDAP ±1/16" (2mm) Page Number of Size A B C D E F G H J K M N P Q R 30, 45 12 1/8 25 5/8 10 13 13/16 26 21 9/16 5 3/16 6 1/2 2 11/16 3 7/8 17 3/8 11/16 4 5/16 13 9 9/16 60 15 1/8 25 5/8 13 13 13/16 27 21 9/16 7 7/8 6 1/2 5 1/2 3 7/8 17 3/8 11/16 4 5/16 13 10 1/2 75 15 1/8 25 5/8 13 13 13/16 27 5/8 21 9/16 7 7/8 6 1/2 5 1/2 3 7/8 17 3/8 11/16 4 5/16 13 10 1/2 100 23 1/8 25 5/8 21 13 13/16 28 5/8 21 9/16 14 1/2 6 1/2 8 3/4 3 7/8 17 3/8 11/16 4 5/16 13 10 1/2 125 23 1/8 25 5/8 21 13 13/16 29 3/8 21 9/16 14 1/2 6 1/2 8 3/4 3 7/8 17 3/8 11/16 4 5/16 13 10 1/2 150, 175, 200 20 1/8 38 3/16 16 2 3 42 35 3/8 8 1/2 8 1/4 5 7/16 6 1/2 25 11/16 1 3/8 8 3/16 22 3/16 16 3/8 225, 250 26 1/8 38 3/16 22 23 42 35 3/8 13 1/16 8 13/16 9 6 1/2 25 11/16 1 3/8 8 3/16 22 3/16 15 5/8 300, 350, 400 34 1/8 4 1 30 23 42 35 3/8 17 1/16 9 11 13/16 7 5/16 27 11/16 1 3/8 8 3/16 22 3/16 16 3/16 Size A B C D E F G H J K M N P Q R 30, 45 (308) (651) (254) (351) (660) (548) (132) (165) (68) (98) (441) (17) (110) (330) (243) 60 (384) (651) (330) (351) (686) (548) (200) (165) (140) (98) (441) (17) (110) (330) (267) 75 (384) (651) (330) (351) (702) (548) (200) (165) (140) (98) (441) (17) (110) (330) (267) 100 (587) (651) (533) (351) (727) (548) (368) (165) (222) (98) (441) (17) (110) (330) (267) 125 (587) (651) (533) (351) (746) (548) (368) (165) (222) (98) (441) (17) (110) (330) (267) 150, 175, 200 (511) (970) (406) (584) (1,067) (899 ) (216) (210) (138) (165) (652) (35) (208) (564) (416) 225,250 (664) (970) (559) (584) (1,067) (899) (332) (224) (229) (165) (652) (35) (208) (564) (397) 303050, (867) (1,041) (762) (584) (1,067) (899) (433) (229) (300) (186) (703) (35) (208) (564) (411) PandQ- Hanger Dimensions for 4 -pt Suspension t T 1� a- I I 3/8"-16 Female Thread l� - all suspension points t TOP VIEW R - Hanger Dimension for 2 -pt Suspension 1 CLEARANCES FROM COMBUSTIBLES Form RZ-C-UH (Version 1-1) Page 10 Thermostat Connection (30-125 Vertical; 150-400 Horizontal) 1, G Line Voltage Inlet (connects at circuit board) Combustion Air Inlet 4- 4""'" H —► External Gas Connection 4 F E Vent Connection (see Technical Data for size) RIGHT SIDE VIEW (Access Panel) Size B D ► Access Panel Non -Access Side Bottom* Rear inches f A C li inches mm REZNOR mm inches mm inches IIIII.7,1"..miume inches mm FRONT `l — VIEW It -- 152 i. 457 1 25 1 25 18 VE E2 150-400 4 CLEARANCES FROM COMBUSTIBLES Form RZ-C-UH (Version 1-1) Page 10 Thermostat Connection (30-125 Vertical; 150-400 Horizontal) 1, G Line Voltage Inlet (connects at circuit board) Combustion Air Inlet 4- 4""'" H —► External Gas Connection 4 F E Vent Connection (see Technical Data for size) RIGHT SIDE VIEW (Access Panel) Size Top Flue Connector Access Panel Non -Access Side Bottom* Rear inches mm inches mm inches mm inches mm inches mm inches mm 30-125 1 25 6 152 18 457 1 25 1 25 18 457 150-400 4 102 6 152 18 457 2 51 1 25 18 457 *Suspend the heater so that the bottom is a minimum of 5' (1.5M) above the floor. 2. Exhaust Fans: EF -1 thru EF -3 Type CRBA Belt Drive Centrifugal Power Roof Ventilators INDUSTRIES DIVISION AMERICAN COOLAIR CORPORATION P.O. Box 2300 Jacksonville, Florida 32203 Phone: (904) 389-3646 Fax: (904) 387-3449 • (904) 381-7560 E-mail: fans@coolair.com Internet: www.coolair.com I 8" STD. HEIGHT 1 5/8- 1" D H O.D. 1 5/a• J I.D. i l re- E SQ.� Standard Fan Features Optional Features • Non -overloading aluminum wheel • UL Label for Standard 705. computer balanced. • Disconnect switch (loose or • Force ventilated motor compartment factory mounted and wired). isolated from airstream. • Backdraft damper. • Variable pitch motor pulley. • Roof curb (damper shelf • Vibration isolators on drive frame. optional). • Weatherproof spun aluminum housing. • Epoxy coating. • NEMA Standard open drip -proof motors. • Overlapping wheel/inlet venturi. • Heavy duty self -aligning pillow -block bearings with cast iron housing. • AMCA label for air and sound. • Polypropylene birdscreen. F SQ. G SQ. Sheet of 11/r THICK INSULATION B DIA. r ISM klUS1 I i A SQ. I.D. SIZE Ventilator Dimensions Roof Curb and Damper Dimensions A B C D E F G H J 06-10 18 231/8 201/2 241/2 121/2 10 111/4 161/2 131/4 12-15 23 28 5/8 22 1/2 29 1/2 17 1/2 15 16 1/4 21 1/2 18 1/4 16-20 30 35 1/2 24 5/8 36 1/2 24 1/2 22 23 1/4 28 1/2 25 1/4 24 34 42 3/4 32 1/2 40 1/2 28 1/2 26 27 1/4 32 1/2 29 1/4 30 40 50 1/4 36 3/4 46 1/2 34 1/2 32 33 1/4 38 1/2 35 1/4 36 46 61 3/4 44 1/4 52 1/2 40 1/2 38 39 1/4 44 1/2 41 1/4 44 56 711/4 49 621/2 501/2 48 491/4 541/2 , 511/4 52 65 83 3/4 55 1/2 71 1/2 59 1/2 57 58 1/4 63 1/2 601 /4 Specifications 0 Check here for UL 705. FAN DATA MOTOR DATA Dimensions In inches 2" FAN NO. QTY. MODEL NO. CFM SP RPM SONES HP RPM VOLTAGE PH HZ ENCLOSURE ACCESSORIES AND REMARKS EF -1 1 CRBA13-1/3 1575 .125 994 6.4 1/3 1750 115 1 60 OPEN includes backdraft damper and curb EF- 2, 3 2 CRBA16-1/2 2150 .125 994 8.3 1/2 1750 115 1 60 OPEN includes backdraft damper and curb PROJECT LOCATION ENGINEER CONTRACTOR SUBMITTED BY APPROVED BY DATE DATE Form No. 720-30-3 (5-00) Printed in U.S.A. ©American Coolair Corporation 2000 3. Electric Wall Heater: EWH-1 EWH-1 PI( -A -WATT® - THE ORIGINAL FAN FORCED - BEST o Smart Limit Protection® ▪ Pic -A -Watt® Element o C -Frame Motor o Squirrel Cage Blower o Quiet Running • Multiple Wattage Element • 20 Gauge Powder Coated Grill with contemporary die formed round comers. • Standard Color - Bright White • Bi -Metallic Limit • Safety thermal cutout trips and tums off heater. • Optional 1 -Pole or ENERGY EFFICIENCY SEE PAGE 110 2 -Pole unit mount thermostat 45°-80° • Optional surface wall box • Optional Color - Almond • Optional ULTRA Custom Bar Grill • Available in Stainless Steel Refer to Index Pic -A -Watt ENGINEERING SP=CIFICATIONS: ,=, armommumrsamoiN The original multi -watt steel fin heater. This is a unique King de- sign that allows you to change the wattage of the heater by simply disconnecting a color coded ter- minal. But the best feature of this unique heater is how quiet it is. The high mass steel element transfers heat quietly and effi- ciently. The sleek appearance gives the desired look of a regis- ter grill used in central forced air systems. This is our most popular heater for a single family residence or upscale condominium. The ele- ment has a five year warranty and 12 year history of reliability. For www.king-electric.com PAW SERIES best results use with an electronic line voltage wall thermostat. NOTE: Heaters cannot be installed vertically. Contractor shall supply and install, PAW -series wall -mounted forced - air electric heaters, manufactured by King Electrical Mfg. Company, of the wattage and voltage as indicated on the plans. Ratings: Heaters shall be available in wattages of 250 to 2,250 at 120, 208, 240, or 277 volts. Blower and Motor: A tangential cylindrical blower, delivering 65 CFM, shall be driven by a shaded pole, permanently lubricated, C -frame type motor with impedance protection and sealed bear- ings. Motors shall be the same voltage as the heater. Elements: Elements assemblies shall be non -glowing design. El- ement assemblies shall consisting of three steel sheathed heat- ing tubes in a fumace brazed, plate finned, block design. Each sheathed tube shall contain coiled Ni -Chrome wire, embedded in an insulator of magnesium oxide. The element assembly shall provide a minimum of seven (7) possible wattage configurations available for selection during field installation. The use of exter- nal resistors, diodes, or other weak links to obtain multiple watt- ages will not be acceptable. Thermal Overload: Heaters shall be equipped with thermal over- load protection, which disconnects elements in the event normal operating temperatures are exceeded. The thermal overload pro- tection device shall automatically reset when normal operating temperatures are reached or manually reset by the thermostat. Wall Can: The wall can shall be 20 gauge electro -galvanized steel and shall contain a minimum of three (3) knockouts through which power leads are brought. The wall can shall have a depth gauge indicator, and a factory installed, insulated and stranded copper grounding wire. Minimum Clearance to Floors and Sidewalls. Zero clearance to combustibles. Grill: The grill shall be louvered, one piece design with rounded edges on all four sides, with rounded comers to prevent snags from contact with other materials. The grill shall be epoxy powder coated in white or almond. Approval: Heaters shall be listed and approved by Underwriters' Laboratories or equal. 8 w KING ELECTRICAL MFG. (0. • 9131 10TH AVENUE SOUTH • SEATTLE, WA 98108 • TEL: 206.762.0400 • FAX: 206.763.7738 1:11 king www.king-electric.com 71215 PAW Series 120 Volts 1500 Watts Standard Color: Bright White ULTRA Grill (No Built -In Thermostat) Patent Pending al -1 uitA,LLAT ''11.1)1i '9 kc''l ''i V] 9 ] %'J Ltx S1 21111111�7 lxt_ Wily: v1;V:i"ii 'il.i 1Ci)J1Ri lin 1400401 .li.1,1' t in n t II 111A(11;1( ,n0t.0;i IMI ill, Lt!I! : **KO% O( ;1111. 250500 750 1000.1250.1500 PAW1215 16303 PIC -A -WATT Surface Can - Almond 13WL x 4%"W x 7%"H 19298 4 9 500 750 1000 1250.1500.1750-225C 16304 PAW2022 00512 PAW2422 16300 1000.2000 PAW -GUARD Safety Guard for PAW PAW2720 16302 i 1617161 AI))) ;4.1111i,'J4 941(111Ffi `u' -U For ULTRA Custom Bar Grill - Not available with built-in thermostat. 12 -I For Interior and Grill only (No Wall Can) 7.5 -1-1 For Interior only (No Can or Grill) 6 -OGA For 13"H x 13WW Retrofit Grill 11 -OGB For 8'/"H x 17"W Retrofit Grill 11 DIMENSIONS 12W -� Wall Can Top Bottom � r• T 6" 1 Front PT -1 - Stat Kit SPST h4"-1 PT -2 - Stat Kit DPST 0 '' Recessed Wall Can Left Side 13W Grill T 7y2. 1 Mounting poles ACCESSORIES: ill t ( _ WAN 40 . Win r! AlilJM' r'",1I1I inti11..0110 PAWF Recess Can W/Flange (Remodel) 16319 3.5 PAWIC Recess Wall Can 00515 3.5 PAWS PIC -A -WATT Surface Can - White 13%"L x 4%"W x 7%"H 16305 4 PAWS -A PIC -A -WATT Surface Can - Almond 13WL x 4%"W x 7%"H 19298 4 PAWG Grill - White 16304 2 PAWG-A Grill - Almond 16335 2 PAW -GUARD Safety Guard for PAW 16550 3.5 PAWOG-A 13"H x 13"W Retrofit Grill 00555 3 PAWOG-B 8%"H x 17"W Retrofit Grill 00560 3 ULTRA -W ULTRA Grill - White 18740 4 ULTRA -A ULTRA Grill - Almond 18745 4 PT -1 SP STAT KIT 16306 .5 PT -2 DP STAT KIT 16307 .5 PAW -DISPLAY Counter Top Display 16308 20 Standard left hand feed for power supply. PAWF - Flanged Wall (an for Remodel Work or Wood Walls. KING ELECTRICAL MFG. (0. • 9131 10TH AVENUE SOUTH • SEATTLE, WA 98108 • TEL: 206.762.0400 • FAX: 206.763.7738 10/1/2018 City of Tukwila Department of Community Development HEATH HAMBLEN 4102 B PLACE NW AUBURN, WA 98001 RE: Permit No. M18-0047 SEBCO WAREHOUSE Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 11/7/2018. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 11/7/2018, your permit will become null and void and any further work on the project will re uire a new permit and associated fees. Thank you for your cooperation in t s Sincerely, ;\ achelle Ripley Permit Technician File No: M18-0047 matter. 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 _HERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M18-0047 DATE: 04/11/18 PROJECT NAME: SEBCO WAREHOUSE SITE ADDRESS: 11060 TUKWILA INT'L BLVD X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: Building Division Public Works 1-13-( El kM PrWo VI(6 Fire Prevention Fire Prevention Structural Planning Division ❑ Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 04/12/18 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 05/10/18 Approved ❑ Approved with Conditions Corrections Required ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire ❑ Ping 0 PW ❑ Staff Initials: 12/18/2013 UNIVERSAL REFRIGERATION I-\ Home. Espanol Contact Safety & Health Claims & Insurance Washington State Department of 4Labor & Industries Page 1 of 2 Search L&I A -Z Index Help My L&1 Workplace Rights Trades & Licensing UNIVERSAL REFRIGERATION INC Owner or tradesperson Principals GATES, CHRISTOPHER A, PRESIDENT GALVIN, BRYAN S, VICE PRESIDENT GATES, CHRIS A, AGENT VERNON, GUY E (End: 01/01/1980) JACKSON, SHELDON G (End: 01/01/1980) OSENBAUGH, CHARLES R (End: 01/01/1980) RAEDER, STEVEN C, PRESIDENT (End: 03/29/2012) Doing business as UNIVERSAL REFRIGERATION INC WA UBI No. 600 599 723 PO BOX 614 AUBURN, WA 98071-0614 253-939-5501 KING County Business type Corporation Governing persons BRYAN GALVIN CHRIS GATES; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties COMMERCIAL/INDUSTRIAL/REFRIG License no. UNIVERI159RF Effective — expiration 12/06/1985— 04/01/2020 Bond AMERICAN STATES INS CO Bond account no. EX903622 Active. Meets current requirements. $6,000.00 Received by L&I Effective date 03/18/2002 12/06/2001 Expiration date Until Canceled Insurance Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=600599723&LIC=UNIVERI159RF&SAW= 5/11/2018 UNIVERSAL REFRIGERATION INC Ohio Cas Ins Co Policy no. BK053333383 $1,000,000.00 Received by L&I Effective date 03/19/2018 04/01/2017 Expiration date 04/01/2019 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts ..................................... No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations ..................................... No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID 469,068-01 Doing business as UNIVERSAL REFRIGERATION INC Estimated workers reported Quarter 1 of Year 2018 "31 to 50 Workers" L&I account contact T5 / MELISSA VEST (360)902-5613 - Email: VESM235@lni.wa.gov Account is current. Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 04/09/2014 Inspection no. 316993518 Location 6742 185th Ave NE Redmond, WA 98052 Violations Page2of2 Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=600599723&LIC=UNIVERI159RF&SAW= 5/11/2018 PENDING CITY APPROVAL) ELECTRIC WALL HEATER SCHEDULE GAS PIPING REGULATOR DETAIL BRAND NAME MODEL NUMBER o® VOLTAGE 0 / , ® KING _ 1.5 115/1 SPRINKLER RISER ROOM ILG CRBA13 1/3 1,575 .125" 1/3 HP CV 115/10 6.4 SONES 14"x14" ROOF EF 2-3 ILG CRBA16-1/2 2,150 .125 1/2 HP CV 115/10 8.3 SONES 22"x22" ROOF 115/10 11.0 269 LBS KD GAS METER ZD12 VVT DAMPER 0 THERMOSTAT T -BAR SUPPLY DIFFUSER b---,--___ T -BAR RETURN GRILLE HARDLID SUPPLY DIFFUSER I HARDLID RETURN GRILLE FD FIRE DAMPER FSD FIRE SMOKE DAMPER VOLUME DAMPER L-- SD SMOKE DETECTOR FLEXIBLE DUCT SA/RA fpROUND DUCT UP ROUND DUCT DOWN 214-11 DIFFUSER TAG 0 0 0 10 409.4 MP REGULATOR VALVES A LISTED SHUTOFF VALVE SHALL BE INSTALLED IMMEDIATELY AHEAD OF EACH MP REGULATOR .0 409.5 APPLIANCE SHUTOFF VALVE EACH APPLIANCE SHALL BE PROVIDED WITH A SHUTOFF VALVE IN ACCORDANCE WITH SECTION 409.5.1, 409.5.0, OR 409.5.3 03 VENT LIMITERS ARE DESIGNED FOR USE INDOORS AND IN SPACES WHERE LIMITING THE AMOUNT OF GAS ESCAPEMENT DUE TO DIAPHRAGM FAILURE IS CRITICAL. VENT LIMITERS ARE NOT TO BE USED OUTDOORS IF THEY ARE EXPOSED TO THE ENVIRONMENT. 13A15 VENT PROTECTOR IS AVAILABLE FOR OUTDOOR USE WHEN VENT PROTECTION IS REQUIRED. ® 411.1.6 UNIONS A UNION FITTING SHALL BE PROVIDED FOR APPLIANCES CONNECTED BY RIGID METALLIC PIPE. SUCH UNIONS SHALL BE ACCESSIBLE AND LOCATED WITHIN 6 FEET (1829 MM) OF THE APPLIANCE. 05 410.1 PRESSURE REGULATORS A LINE PRESSURE REGULATOR SHALL BE INSTALLED WHERE THE APPLIANCE IS DESIGNED TO OPERATE AT A LOWER PRESSURE THAN THE SUPPLY PRESSURE. LINE PRESSURE GAS REGULATORS SHALL BE LISTED AS COMPLYING WITH ANSIZ21.80. ACCESS SHALL BE PROVIDED TO PRESSURE REGULATORS. PRESSURE REGULATORS SHALL BE PROTECTED FROM PHYSICAL DAMAGE. REGULATORS INSTALLED ON THE EXTERIOR OF THE BUILDING SHALL BE APPROVED FOR OUDOOR INSTALLATION. © A TEE FITTING WITH ONE OPENING CAPPED OR PLUGGED SHALL BE INSTALLED BETWEEN THE MP REGULATOR AND ITS UPSTREAM SHUTOFF VALVE. SUCH TEE FITTING SHALL BE POSITIONED TO ALLOW THE CONNECTION OF A PRESSURE -MEASURING INSTRUMENT AND TO SERVE AS A SEDIMENT TRAP. .0 A TEE FITTING WITH ONE OPENING CAPPED OR PLUGGED SHALL BE INSTALLED NOT LESS THAN 10 PIPE DIAMETERS DOWNSTREAM OF THE MP REGULATOR OUTLET. SUCH TEE FITTING SHALL BE POSITIONED TO ALLOW THE CONNECTION OF A PRESSURE -MEASURING INSTRUMENT. ELECTRIC WALL HEATER SCHEDULE ID BRAND NAME MODEL NUMBER KW VOLTAGE LOCATION EWH-1 KING PAW1215 1.5 115/1 SPRINKLER RISER ROOM EXHAUST FAN SCHEDULE ID BRAND NAME MODEL NUMBER CFM SP HP/AMP FLOW V/PH SOUND RATING DUCT LOCATION EF -1 ILG CRBA13 1/3 1,575 .125" 1/3 HP CV 115/10 6.4 SONES 14"x14" ROOF EF 2-3 ILG CRBA16-1/2 2,150 .125 1/2 HP CV 115/10 8.3 SONES 22"x22" ROOF GAS UNIT HEATER SCHEDULE ID BRAND NAME MODEL NUMBER CFM Btuh INPUT Btuh OUTPUT EFFICIENCY GAS CONNECTION VENT OUTLET V/PH FLA WT. UH 1-2 REZNOR UDAP125 1,537 120,000 99,600 83% 1/2" 4"0 115/10 5.1 101 LBS UH 3-4 REZNOR UDAP300 3,843 300,000 249,000 83% 3/4" 6"0 115/10 11.0 269 LBS LNOTE: These plans are diagrammatical only. Please verify all dimensions at job site. FILE COPY Permit No. le • ODV1 Plan review approval is subject to errors and omissions. Approval of construction documents doss not authorize the violation of any adopted coda or ordinance. Receipt of approved Field Copy and conditions is acknowledged: By: Date: ..5--(///,?` City of Tukwila BUILDING DIVISION REVISIONS No changes shill ho made to the ;cope of work witho�.:` pr-ci. approval of 9 Tukwila PiPidrip Division. 1 NOTF: ^V S CTi. will t. ;:,.,, , )1!-,r....,! pian submittal i 1 ma''j . 1,j1i 2 cc( f.:i Bolla i jean r v!':1.v fees 'SEPARATE' PEaliT i REQUiRED FOR: Mechanical Electrical 1PEumbing Gas Piping C'i y o, Tukwila ELM 5"V":"2, DIVISIOsN HVAC LEGEND HVAC ABBREVIATIONS 0 0 INLINE EXHAUST FAN(S) AFF BDD BTUH CD CFM CU DB DH DOAS DN EC EER EF EG ERV ESP EXH FCU FD FPM FSD GA GF GRD HP ID IHP IRH KW MBH MCD NC NIC NTS OBD OC OD OHP OSA OSCI POC RA RAG RPM RTU SA SG SP SSG TBD TG TYP UH VFD VTR WT ABOVE FINISHED FLOOR BACKDRAFT DAMPER BRITISH THERMAL UNIT PER HOUR CEILING DIFFUSER CUBIC FEET PER MINUTE CONDENSING UNIT DECIBEL DUCT HEATER DEDICATED OUTSIDE AIR SYSTEM DOWN EVAPORATOR COIL ENERGY EFFICIENCY RATIO EXHAUST FAN EXHAUST GRILLE ENERGY RECOVERY VENTILATOR EXTERNAL STATIC PRESSURE EXHAUST FAN COIL UNIT FIRE DAMPER, FLOOR DRAIN FEET PER MINUTE FIRE AND SMOKE DAMPER GAUGE GAS FURNACE GRILLE, REGISTER, DIFFUSER HORSEPOWER, HEAT PUMP INSIDE DIMENSION INDOOR (SECTION) HEAT PUMP INFRARED HEATER KILOWATT THOUSAND BTU PER HOUR MOTORIZED CONTROL DAMPER NOISE CRITERIA NOT IN CONTRACT NOT TO SCALE OPPOSED BLADE DAMPER ON CENTER OUTSIDE DIMENSION OR DIAMETER OUTDOOR HEAT PUMP OUTSIDE AIR OWNER SUPPLIED CONTRACTOR INSTALLED POINT OF CONNECTION RETURN AIR RETURN AIR GRILLE REVOLUTIONS PER MINUTE ROOFTOP UNIT SUPPLY AIR SUPPLY GRILLE STATIC PRESSURE SIDEWALL SUPPLY GRILLE TO BE DETERMINED TRANSFER GRILLE TYPICAL UNIT HEATER VARIABLE FREQUENCY DRIVE VENT TO ROOF VARIABLE VOLUME AND TEMPERATURE ( FILE COPY Permit No. le • ODV1 Plan review approval is subject to errors and omissions. Approval of construction documents doss not authorize the violation of any adopted coda or ordinance. Receipt of approved Field Copy and conditions is acknowledged: By: Date: ..5--(///,?` City of Tukwila BUILDING DIVISION REVISIONS No changes shill ho made to the ;cope of work witho�.:` pr-ci. approval of 9 Tukwila PiPidrip Division. 1 NOTF: ^V S CTi. will t. ;:,.,, , )1!-,r....,! pian submittal i 1 ma''j . 1,j1i 2 cc( f.:i Bolla i jean r v!':1.v fees 'SEPARATE' PEaliT i REQUiRED FOR: Mechanical Electrical 1PEumbing Gas Piping C'i y o, Tukwila ELM 5"V":"2, DIVISIOsN HVAC LEGEND 0 0 INLINE EXHAUST FAN(S) ROOFTOP EXHAUST FAN ( ) illit SIDEWALL EXHAUST FAN ■ VAV FAN BOX 1 CEILING EXHAUST FAN r KD GAS METER ZD12 VVT DAMPER 0 THERMOSTAT T -BAR SUPPLY DIFFUSER T -BAR RETURN GRILLE HARDLID SUPPLY DIFFUSER I HARDLID RETURN GRILLE FD FIRE DAMPER FSD FIRE SMOKE DAMPER VOLUME DAMPER L-- SD SMOKE DETECTOR FLEXIBLE DUCT SA/RA fpROUND DUCT UP ROUND DUCT DOWN 214-11 DIFFUSER TAG FILE COPY Permit No. le • ODV1 Plan review approval is subject to errors and omissions. Approval of construction documents doss not authorize the violation of any adopted coda or ordinance. Receipt of approved Field Copy and conditions is acknowledged: By: Date: ..5--(///,?` City of Tukwila BUILDING DIVISION REVISIONS No changes shill ho made to the ;cope of work witho�.:` pr-ci. approval of 9 Tukwila PiPidrip Division. 1 NOTF: ^V S CTi. will t. ;:,.,, , )1!-,r....,! pian submittal i 1 ma''j . 1,j1i 2 cc( f.:i Bolla i jean r v!':1.v fees 'SEPARATE' PEaliT i REQUiRED FOR: Mechanical Electrical 1PEumbing Gas Piping C'i y o, Tukwila ELM 5"V":"2, DIVISIOsN REVIEWED FOR CODE COMPLIANC APPROVED MAY 01 2018 • Ikk\ "` City of Tukwila BUILDING DIVISIO RECEIVED CITY OF TUKYWILA APR is 2018 PERMi F CENTER MP€ oottl - AIR CONDITIONING - HEAT PUMPS - REFRIGERATION - CONTRACTOR'S LICENSE NUMBER: UNIVERI 159RF AUBURN: (253) 939-5501 TACOMA: (253) 922-3141 SEATTLE: (253) 839-2126 FAX (253) 735-3432 P.O. BOX 614 - AUBURN, WASHINGTON 98071 ©UNIVERSAL REFRIGERATION DRAWING -2001 PRINT/PLOT DATE: 4/4/18 DRAFTER: DESIGNER: PROJECT MANAGER: HH JOB NUMBER: 17254 SHEET NUMBER: M -C HVAC NOTES 1. DUCT INSULATION TO MEET THE REQUIREMENTS OF SECT- ION C403.2.8 OF THE 2015 WSEC AND SECTION 604 OF THE IECC (INTERNATIONAL ENERGY CONSERVATION CODE). 2. SMOKE DETECTOR(S) INSTALLED IN MAIN RETURN AIR DUCTS PER SECTION 606 OF THE 2015 IMC. HVAC SMOKE DUCT DETECTORS SHALL SHUT DOWN POWER TO THE UNIT UPON ACTIVATION AND A "SUPERVISORY" ZONE SHALL BE INITIATED AT FIRE ALARM PANEL UPON SMOKE DUCT DETECTOR ACTIVATION. IMC SECTION 606.2.1. 3. DUCTWORK-MAINTRUNK IS R-4.2 IN CONDITIONED SPACES AND R-8 IN UNCONDITIONED SPACES AS PER THE WSEC. 4. ALL SINGLE PACKAGE HVAC UNITS SHALL BE INSTALLED WITH ECONOMIZERS PER MANUFACTURER'S INSTALLATION INSTRUCTIONS PER I.M.C. 2015, SECTION 403, CHAPTER 6, AND SHALL OPERATE, PER W.S.E.C. 2015, SECTION C403.3.1. 5. EQUIPMENT INSTALLATION INSTRUCTIONS TO BE ON-SITE FOR INSPECTIONS. 6. ALL HVAC EQMT. TO BE LABELED TO THE SPACE SERVED. 7. DUCTS TO BE SUPPORTED AT EACH DIRECTION CHANGE VERTICAL AT 12'-0" MAX., HORIZONTAL AT 10'-0" MAX. WITH STRAP, OR 8'-0" MAX. F TRAPEZE SUPPORT. 8. THERMOSTAT TO BE SEVEN-DAY TYPE AND HAVE NIGHT SETBACK WITH 5 DEGREE DEADBAND. 9. THE HVAC INSTALLATION SHALL BE COMPLETE WHEN ALL SECTIONS OF C408 WSEC HAVE BEEN SATISFIED. THIS SHALL INCLUDE AS -BUILT DRAWINGS, SUBMITTALS, O&M MANUALS, SYSTEM BALANCE REPORT, AND A COMMIS- SIONING REPORT. 10. DUCT SEALING SHALL MEET REQUIREMENTS OF WSEC C403.2.8. DUCT WORK WHICH IS DESIGNATED TO OPERATE AT PRESSURES ABOVE 1/2" WATER COLUMN STATIC PRESSURE SHALL BE SEALED AS FOLLOWS: 1. STATIC PRESSURE 1/2 INCH TO 3 INCHES: SEAL ALL TRANSVERSE JOINTS AND LONGITUDINAL SEAMS. SPIRAL LOCK SEAMS IN ROUND AND FLAT OVAL DUCT WORK DO NOT REQUIRE SEALING; HOWEVER, OTHER SEAMS SHALL BE SEALED. 2. STATIC PRESSURE ABOVE 3 INCHES: SEAL ALL TRANSVERSE JOINTS, LONGITUDINAL SEAMS AND DUCT WALL PENETRATIONS. 11. WSEC FORMS, DUCTING PLANS, BALANCING FEATURES, AS WELL AS VENTILATION REQUIREMENTS (AS PER TABLE 403.3.1.1, 2015 IMC MINIMUM VENTILATION RATES) AND OCCUPANCY, ALONG WITH A MECHANICAL PERMIT AT THE TIME OF THE TENANT IMPROVEMENT PERMIT. REVIEWED FOR CODE COMPLIANC APPROVED MAY 01 2018 • Ikk\ "` City of Tukwila BUILDING DIVISIO RECEIVED CITY OF TUKYWILA APR is 2018 PERMi F CENTER MP€ oottl - AIR CONDITIONING - HEAT PUMPS - REFRIGERATION - CONTRACTOR'S LICENSE NUMBER: UNIVERI 159RF AUBURN: (253) 939-5501 TACOMA: (253) 922-3141 SEATTLE: (253) 839-2126 FAX (253) 735-3432 P.O. BOX 614 - AUBURN, WASHINGTON 98071 ©UNIVERSAL REFRIGERATION DRAWING -2001 PRINT/PLOT DATE: 4/4/18 DRAFTER: DESIGNER: PROJECT MANAGER: HH JOB NUMBER: 17254 SHEET NUMBER: M -C SCOPE OF WORK JOB# 17254 1. INSTALL (1) ELECTRIC WALL HEATER. 2. INSTALL (3) EXHAUST FANS. 3. INSTALL (4) NATURAL GAS UNIT HEATERS. 4. INSTALL NATURAL GAS PIPING. REVIEWED FOR CODE COMPLIANC APPROVED MAY 01 2018 • Ikk\ "` City of Tukwila BUILDING DIVISIO RECEIVED CITY OF TUKYWILA APR is 2018 PERMi F CENTER MP€ oottl - AIR CONDITIONING - HEAT PUMPS - REFRIGERATION - CONTRACTOR'S LICENSE NUMBER: UNIVERI 159RF AUBURN: (253) 939-5501 TACOMA: (253) 922-3141 SEATTLE: (253) 839-2126 FAX (253) 735-3432 P.O. BOX 614 - AUBURN, WASHINGTON 98071 ©UNIVERSAL REFRIGERATION DRAWING -2001 PRINT/PLOT DATE: 4/4/18 DRAFTER: DESIGNER: PROJECT MANAGER: HH JOB NUMBER: 17254 SHEET NUMBER: M -C - AIR CONDITIONING - HEAT PUMPS - REFRIGERATION - CONTRACTOR'S LICENSE NUMBER: UNIVERI 159RF AUBURN: (253) 939-5501 TACOMA: (253) 922-3141 SEATTLE: (253) 839-2126 FAX: (253) 735-3432 P.O. BOX 614 - AUBURN, WASHINGTON 98071 ©UNIVERSAL REFRIGERATION DRAWING -2001 SZUB'Eo : iu 2 PSI GAS METER 238 CFH 1,284 CFH @ 750' l o ° 3/4" STUB /2'1 -DOWN TO M ET* 1-1/4" ° A 1,046 CFH @ 750' 119 CFH @ 75 927 CFH @ 750' 4"01 -" (TYP. UH 1-2) AREHOUSE 1- /4" 808CFH @750' 6"0 VTR (TYP. UH 3-4) 285 CF 0 U Do w NTERNATIONAL BLVD SEMI -HEAT CALCULATION - WRHS " " WAREHOUSE = (CFM/SF) X (SQ FT) " = (.06) x (26,006 SQ FT') " = 1,560 MINIMUM CFM ACTUAL CFM = 1,575 TOTAL CFM EQUIPMENT OUTPUT TOTAL = BTUH/SQ. FT. = BTUH/SQ. FT. = (7.66) BTUH/SQ. FT. WAREHOUSE SQUARE FOOTAGE (2) UNIT HEATERS x (199,200) BTUH OUTPUT (26,006) SQ. FT. (199,200) BTUH (26,006) SQ. FT. 1- /4" 808CFH @750' 6"0 VTR (TYP. UH 3-4) 285 CF 0 U Do w NTERNATIONAL BLVD REVIEV\.ED CODE COWL APPROV 6fRI-NT/PLOT DATE: NCE 4/4/18 DRAFTER: 12 ARW DESIGNER: u DI HH iBROJECT MANAGER: HH APR19` JOB NUMBER: LNOTE: These plans are diagrammatical only. Please verify all dimensions at job site. WAREHOUSE HVAC PLAN (WEST) SCALE: 1/16" =1'-0" b0 PENDING -CITY APPROVAL, 17254 CENTER:: SHEET NUMBER: M - 1 WAREHOUSE VENTILATION CALCULATION " " WAREHOUSE = (CFM/SF) X (SQ FT) " = (.06) x (26,006 SQ FT') " = 1,560 MINIMUM CFM ACTUAL CFM = 1,575 TOTAL CFM REVIEV\.ED CODE COWL APPROV 6fRI-NT/PLOT DATE: NCE 4/4/18 DRAFTER: 12 ARW DESIGNER: u DI HH iBROJECT MANAGER: HH APR19` JOB NUMBER: LNOTE: These plans are diagrammatical only. Please verify all dimensions at job site. WAREHOUSE HVAC PLAN (WEST) SCALE: 1/16" =1'-0" b0 PENDING -CITY APPROVAL, 17254 CENTER:: SHEET NUMBER: M - 1 ff."-E2LTU©ari - AIR CONDITIONING - HEAT PUMPS - REFRIGERATION - CONTRACTOR'S LICENSE NUMBER: UNIVERI 159RF AUBURN: (253) 939-5501 TACOMA: (253) 922-3141 SEATTLE: (253) 839-2126 FAX (253) 735-3432 P.O. BOX 614 - AUBURN, WASHINGTON 98071 ©UNIVERSAL REFRIGERATION DRAWING -2001 808 CFH @ 750' OE 6"0 VTR (TYP. UH 3-4 285 CFH @ 750 1' NAT. GAS 523 CF c=1 @ 750' REVIEW ODE COM APPRO /PLOT DATE: 4/4/18 pESI CitycfrTuwja I BUILDING D VISION NER: PROJECT MANAGER: RECEIVED crrY OF TUKWILA JOB NUMBER: LNOTE: These plans are diagrammatical only. Please verify all dimensions at job site. WAREHOUSE HVAC PLAN (EAST) SCALE: 1/16" = 1'-0" tg) (PENDING OITY APPROVAL) Cs 9 2018 RAilIT CENTER 17254 SHEET NUMBER: M-2 WAREHOUSE)VENTILATION CALCULATION SEMI -HEAT CALCULATION - WRHS EQUIPMENT OUTPUT TOTAL = = = BTUH/SQ. FT. BTUH/SQ. FT. (6.98) BTUH/SQ. FT. WAREHOUSE SQUARE FOOTAGE (2) UNIT HEATERS x (498,000) BTUH OUTPUT (71,396) SQ. FT. (498,000) BTUH (71,396) SQ. FT. REVIEW ODE COM APPRO /PLOT DATE: 4/4/18 pESI CitycfrTuwja I BUILDING D VISION NER: PROJECT MANAGER: RECEIVED crrY OF TUKWILA JOB NUMBER: LNOTE: These plans are diagrammatical only. Please verify all dimensions at job site. WAREHOUSE HVAC PLAN (EAST) SCALE: 1/16" = 1'-0" tg) (PENDING OITY APPROVAL) Cs 9 2018 RAilIT CENTER 17254 SHEET NUMBER: M-2 WAREHOUSE)VENTILATION CALCULATION 1 WAREHOUSE = (CFM/SF) X (SQ FT) = (.06) x (71,396 SQ FT') = 4,284 MINIMUM CFM ACTUAL CFM = 4,300 TOTAL CFM c • REVIEW ODE COM APPRO /PLOT DATE: 4/4/18 pESI CitycfrTuwja I BUILDING D VISION NER: PROJECT MANAGER: RECEIVED crrY OF TUKWILA JOB NUMBER: LNOTE: These plans are diagrammatical only. Please verify all dimensions at job site. WAREHOUSE HVAC PLAN (EAST) SCALE: 1/16" = 1'-0" tg) (PENDING OITY APPROVAL) Cs 9 2018 RAilIT CENTER 17254 SHEET NUMBER: M-2