HomeMy WebLinkAboutPermit M18-0051 - CULINEX - COOLER EXPANSIONCULINEX 360 CORPORATE DR N BLDG 10 MI 8-0051 Parcel No: Address: r -' City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 2623049144 360 CORPORATE DR N BLDG 10 Project Name: CULINEX Permit Number: M18-0051 Issue Date: 7/16/2018 Permit Expires On: 1/12/2019 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: SOUTHCENTER CORPORATE SQUAR 635 ANDOVER PARK W #107 , TUKWILA, WA, 98188 JOHN SCHOFIELD 360 CORPORATE DR N , TUKWILA, WA, 98188 POLAR BEAR MECHANICAL INC 401 NE RAVENNA BL, SUITE 130 , SEATTLE, WA, 98115 POLARBM891PC I 11 Phone: (206) 852-6102 Phone: (425) 967-5827 Expiration Date: 10/3/2019 DESCRIPTION OF WORK: EXPANDING EXISTING COOLER Valuation of Work: $19,200.00 Type of Work: REPLACEMENT Fuel type: ELECT Fees Collected: $464.01 Electrical Service Provided by: Water District: Sewer District: Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 L)i2L7-4 Date: --7, v p —i v / I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permitnd agree to the conditions attached to this permit. Signature: Print me: Date7--/7-2e This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 7: TO SCHEDULE ALL FIRE INSPECTIONS, CALL 206-575-4407. 4: Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required systems shall be extended, altered or augmented as necessary to maintain and continue protection whenever the building is altered, remodeled or added to. Alterations to fire protection systems shall be done in accordance with applicable standards. (IFC 901.4)(ENSURE ADEQUATE SPRINKLER COVERAGE IN THE EXPANDED WALK-IN COOLER.) 2: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide. (NFPA 13-8.6.5.3.3) 1: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2436). 3: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 5: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 6: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. 8: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 9: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 10: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 11: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 12: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 13: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 14: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 15: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 16: ***MECHANICAL PERMIT CONDITIONS*** 17: All mechanical work shall be inspected and approved under Permit Center (206/431-3670). 18: Manufacturers installation instructions shall be available on PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1400 0703 1800 0705 0701 FIRE FINAL MECH EQUIP EFF MECHANICAL FINAL REFRIGERATION EQUIP ROUGH -IN MECHANICAL a separate permit the job site at the issued by the City of Tukwila time of inspection. /- CITY OF TUKWIiA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. Project No. Date Application Accepted: Date Application Expires: '-t-t 10 -11-( (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION King Co Assessor's Tax No.: Site Address: 360 Corp. Dr. N Suite Number: Floor: Tenant Name: PROPERTY OWNER Name: John Schofield Name: CuliNex Ile City: Tukwila State: WA Zip: 98188 Address: 360 Corp. Dr. N. Email: john@culinex.biz City: Tukwila State: WA Zip: 98188 CONTACT PERSON — person receiving ail project communication Name: John Schofield Address: 360 Corp. Dr. N. City: Tukwila State: WA Zip: 98188 Phone: 206 852 6102 Fax: Email: john@culinex.biz New Tenant: ❑ Yes ..No MECHANICAL CONTRACTOR INFORMATION Company Name: Polar Bear Mechanical Address: 401 N.E. Ravenna Blvd. #130 City: Seattle State: WA Zip: 98115 Phone: 206 419 8522 Fax: Contr Reg No.: POLARBM891 PC Exp Date: 10-03-18 Tukwila Business License No.: BUS -0997559 Valuation of project (contractor's bid price): $ 19,200.00 Describe the scopse of work in deta Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement Fuel Type: Electric Gas ❑ Other: H:\ Applications\Forms-Applications On Line\2016 Applications\Mechanical Permit Application Revised I.4-16.docx Revised: January 2016 bh Page 1 of 2 i 1 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Residential, Nighttime Furnace >100k btu Industrial Floor furnace 55 dB(A) Suspended/wall/floor mounted heater 57 dB(A) Appliance vent Commercial Repair or addition to heat/refrig/cooling system 1 Air handling unit 65 dB(A) <10,000 cfm 60 dB(A) Unit Type Qty Air handling unit Residential, Nighttime >10,000 cfm Industrial Evaporator cooler 55 dB(A) Ventilation fan connected to single duct 57 dB(A) Ventilation system Commercial Hood and duct 47 dB(A) Incinerator — domestic 65 dB(A) Incinerator — conun/industrial 60 dB(A) Unit Type Qty' Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-10PM, Monday through Friday and 8AM-10PM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: • Warning devices; • Construction and property maintenance during the daytime hours (7am-lOpm); • Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING�W�`�THO� AG Signature: Date: 4-13-2018 Print Name: John Schofield Day Telephone: 206 852 6102 Mailing Address: 360 Corp. Dr. N. Tukwila WA 98188 City State Zip H:\Applications\Forms-Applications On Line\2016 Applications\Mechanical Permit Application Revised 1-4-16.docx Revised: January 2016 bh Page 2 of 2 f '1 :ash •Register,Receip City of Tukwila DESCRIPTIONS ACCOUNT PermitTRAK QUANTITY PAID $464.01 M18-0051 Address: 360 CORPORATE DR N BLDG 10 Apn: 2623049144 $464.01 MECHANICAL $446.16 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $323.78 PLAN CHECK FEE R000.322.102.00.00 0.00 $89.23 TECHNOLOGY FEE $17.85 TECHNOLOGY FEE R000.322.900.04.00 0.00 $17.85 TOTAL FEES PAID BY RECEIPT: R14243 $464.01 Date Paid: Friday, April 13, 2018 Paid By: CULINEX HOLDINGS LLC Pay Method: CHECK 1092 Printed: Friday, April 13, 2018 10:11 AM 1 of 1 !SYSTEMS INSPECTION NO. INSPECTION RECORD Retain a copy with permit M 1k' -o51 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Project: AL Type of I spectipn: Address: Date Called: Special Instructs • s: UN -I V� 1� Date W nted:3 /�j —� 7' ZOO a.m. p.m. Requester. Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENT •• /4 w 721'etri Inspector: `i7 (0CS 9 Date :9-17 oe REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit 1113-x51 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pro ect%l / 1, uL/ ��ppe of Ins ec on: pAf FAV I— Address: bleb ^ edre b rw-c, Special Instru tions: Da" to Wanted: 7—/7—Z0/er 111, ?..3L 1 0 Requester Vol ecr -F5;2- 61oZ Approved per applica•le codes. Corrections required prior to approval. COMMENTS: .2,,a,., * - Inspector: `n Q ri Date 7./ zoo' REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Btvd., Suite 100. Call to schedule reinspection. INSPECTION NUMBER INSPECTION WORD Retain a copy With permit ��► i �- o65- PERMIT ss PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: C ohvl-eX 7 Type of Inspection: S r ,-�/i4 Address: ,-- Suite #: 5(9 t) (71/sfert4 Hood & Duct: Cgntact Person: /`/ Monitor: Special Instructions: Pre -Fire: Phone No.: pproved per applicable codes. Corrections required prior to approval. COMMENTS: ‹ipy fpv4t,- Needs Shift Inspection: 7 Sprinklers: 7 Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: g Inspector: i2-77,2_-;---4- Date: 7/, b < Hrs.; $100.00 -REINSPECTION FEE REQUIRED. You will receive an invoice•from the City of Tukwila Finance Department. CaII to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 April 25, 2018 City of Tukwila Department of Community Development JOHN SCHOFIELD 360 CORPORATE DR N TUKWILA, WA 98188 RE: Correction Letter # 1 MECHANICAL Permit Application Number M 18-0051 CULINEX - 360 CORPORATE DR N Dear JOHN SCHOFIELD, Allan Ekberg, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING - M DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments. • (GENERAL INFORMATION NOTE) PLAN SUBMITTALS: (Min. size 11x17 to a preferably maximum size of 24x36; all sheets shall be the same size; larger sizes may be negotiable. "New revised" plan sheets shall be the same size sheets as those previously submitted.) "STAMP AND SIGNATURES" (If applicable) For Engineers: "Every page of a plan set must contain the seal/stamp, signature of the licensee(s) who prepared or who had direct supervision over the preparation of the work, and date of signature. Specifications that are prepared by or under the direct supervision of a licensee shall contain the seal/stamp, signature of the licensee and the date of signature. If the "specifications" prepared by a licensee are a portion of a bound specification document that contains specifications other than that of an engineering or land surveying nature, the licensee need only seal/stamp that portion or portions of the documents for which the licensee is responsible." It shall not be required to have each page of "specifications" (calculations) to be stamped and signed; Front page only will be sufficient (WAC 196-23-010 & 196-23-020). Architects: "date" only not required (WAC 308-12-081). (BUILDING REVIEW NOTES) 1. Provide drawings that are clear and drawn to scale. Reduces size sheets shall not be accepted. Clearly mark or cloud where the work is located. Provide manufacturers information of the mechanical relocated or added. Show how the mechanical equipment shall be seismically anchored. Include any other relevant information. Note: Contingent on response to these corrections, further plan review may request for additional corrections. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 Sincerely, Bill Rambo Permit Technician File No. M18-0051 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 1 ANT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M18-0051 PROJECT NAME: CULINEX DATE: 04/13/18 SITE ADDRESS: 360 CORPORATE DR N X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: A 3 Coq Building Division Public Works Fire Prevention Structural Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 04/17/18 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 05/15/18 Approved ❑ Approved with Conditions Corrections Required Denied (corrections entered in Reviews) (ie: Zoning Issues) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only 11 1 CORRECTION LETTER MAILED: 14 Departments issued corrections: Bldg ► Fire D Ping ❑ PW 0 Staff Initials: ____WL 12/18/2013 r PER iIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M18-0051 PROJECT NAME: CULINEX DATE: 07/11/18 SITE ADDRESS: 360 CORPORATE DR N Original Plan Submittal Revision # before Permit Issued X Response to Correction Letter # 1 Revision # after Permit Issued DEPARTMENTS: Building Division Public Works n Fire Prevention Structural n Planning Division UPermit Coordinator n • PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 07/12/18 Structural Review Required REVIEWER'S INITIALS: DATE: n APPROVALS OR CORRECTIONS: DUE DATE: 08/09/18 Approved Corrections Required nApproved with Conditions n n Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: 12/18/2013 Date: � 1 City of Tukwila REVISION SUBMITTAL Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Plan Check/Permit Number:% 9 ✓ oo %' ❑ Response to Incomplete Letter # Response to Correction Letter # ) ❑ Revision # after Permit is Is/sued ❑ Revision requested by a City Building Inspector or Plans Examiner ❑ Deferred Submittal # Project Name:///1/e / /6//r': Project Address: b2 7// Contact Person /01,/ _c,.,Ortfq� Phone Number2067% g5� Summary of Revision: RECEIVED CITU OF TUIKWILA JUL 1 1 2018 PERMIT CNTEI Sheet Number(s): "Cloud" or highlight all areas of revision including date of revisi Received at the City of Tukwila Permit Center by: Entered in TRAKiT on�" [ � %-t W:1Permtt Center\Templates\Forms \Revision Submittal Formdoc Revised. August 2015 POLAR BEAR MECHANICAL INCA lime Espanol Contact Safety & Health Claims & Insurance A Washington State Department of �% Labor & Industries Page 1 of 2 Search L&I A-7. Index Help My T.&I Workplace Rights Trades & Licensing POLAR BEAR MECHANICAL INC Owner or tradesperson Principals BELCHER, GARRY DEWAYNE, PRESIDENT Doing business as POLAR BEAR MECHANICAL INC WA UBI No. 603 145 986 401 NE RAVENNA BLVD 130 SEATTLE, WA 98115 425-967-5827 KING County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. POLARBM891PC Effective — expiration 10/03/2011-10/03/2019 Bond Western Surety Co Bond account no. 62501547 $12,000.00 Received by L&I Effective date 10/09/2015 09/12/2015 Expiration date Until Canceled Bond history Insurance Endurance American Specialty 1 $1,000,000.00 Policy no. dci00549-00 Received by L&I Effective date 01/09/2018 01/08/2018 Expiration date 01/08/2019 Mid -Century Ins Co $1,000,000.00 Policy no. 605133486 Received by L&I Effective date 09/08/2017 09/12/2016 Expiration date Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=603145986&LIC=POLARBM891 PC&SAW= 7/16/2018 POLAR BEAR MECHANICAL INC 09/12/2018 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against tie bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. This company has multiple workers' comp accounts. Active accounts L&l Account ID 231,624-01 ................................ Doing business as POLAR BEAR MECHANICAL INC Estimated workers reported Quarter 1 of Year X018 "31 to 50 Workers" L&I account contact T5 / BETTY WHALIN (360)902-5137 - Email: VABE235@Ini.wa.gov Track this contractor 0 Account is current. Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have bean issued against this contractor. Contractors not al:owed to bid No debarments have been issued against this contractor. Workplace safety and health No inspections during the previous 6 year period. Page 2 of 2 ("Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https://secure.lni. wa.gov/verify/Detail.aspx?UBI=603145986&LIC=POLARBM891PC& SAW= 7/16/2018 1' 8'-10 17'-4" 8'-4" COOLER 1 8'-6„ E3 0" FREEZER S0ti00C80C S0t+0JM£t"2TO80 m O SOb002808 CO 0 S0t'002808 GOG0tr087t,0 S01703/1£421380 S01'002808 1 .21 .g9£ .917 21XE2 00 CL 46.5' x 106' 08C1243CA04040405 (15' HIGH) AM -130 50� --71\-- M cn 0 0 0 0 32.5' ,9b .21 50' 3ESCENT LIG -J L. ao LTJ 03 .-- M ,W ww 08C1243CB040405 o ro CL 46' x 106' cp--�"--29�'--�- C F CL 46,5' x 102' 48' 08c1243CD04040405 (16' HIGH) S' EL-090 48' FLUORESCENT LIGHT M08C1243CE04040505/ 30P CL 46' x 102' 316'- 1 LOCK PANE S FROM THIS SIDE Z0 16.75' 08C1243WC0505 7l/118C 243C05050505 51' d 17,25' (12' 0 0 O 0 0 0 o` N CO 03 v in a 34DR 08C1243WD0505 0 29r1'-- ,. °' 521" .A. 0 FLUORESCENT LIGH CL 23' x $08' CL 46' x 106' 08C1243CB040405 M 0 CL 46' x 208'\N ✓/,( 23' 808106005 58' 4 243A60056005 F11,5' 23' 0 0 0 Ul 0 Fr `a 1/40 CO � -1 12') 48' OLUORESCEN LIGHT I D 1 �3 L_L_ -1 08C1243CF040405 �l CL 46' x 102' 48' FLUORESCENT LIGHT %�I -411 to r -STD DFF (Y, -t r STD M 28P 808006005 T 1 FJ7-- 48�''' �- ---13r ' 34DR $ 08C` 4 VA600505 SOM i» CL 46' x 2518i / 801" z 4 ,24386005600534DR $ atilt L1 t L EXISTING WALLS ARE 22 GA 430 STAINLESS STEEL ch_ 0 F=z---- 9" F �1/ �' / CL 34.5' x 208' 7 O r % ru 46? ,,,,,;46e 0' .r_aJ% ,aril i�S1.O 0 0 - .6 /4', 7. i ink il."' 0 21r cm NOTE: THIS IS AN EXISTING CORNER S0 EXTERIOR IS 22 GA 430 STAINLESS STEEL -21e CL 46' x 208' CL 46' x 208' 34,5' 808906005 69? 0 0 0 N CO CO ic ON Apr d cu cu COOL O Cm cN ER 2 / - 51" MIN. �coc 0 SOt,01S89S cv ///l4 - WV /4//�/���J/. �/�/���//i /r���./�/7/Ce7 %/14.45 i2' 808200405 808200405 308306005 ,1 NOTE: THIS IS AN EXISTING CORNER SO EXTERIOR IS 22 GA 430 STAINLESS STEEL . CL 34' x 81,5' Cr' • 12'V /.44,9VW'/// 5'-0" 5'-8" 30830 405 dCLEAR- - d'. NEW COOLER NEW FREEZER 16'8 9' 3" 11'-8'1 PANELS -vp/001 (v(-frArq 81'S) 1 17'-4" CENTER TO END OF ` SCREED 8'6" - 8'- 104' 20' IIV- 3e 4- 4- 4-- I- 46e 58' 35 1/16' 117 17/32' 37 1 BETWEEN j 55 1/2' FLM08C1243FA0404040521 35'x104' z FLM08C1243F20405040521 36,5' x 104' _.•- 341'-► IN1RA'P 34X20 X570 5221 -+►-34'-*► co 51' 35'-�•-- 521' o► -11 � 7/fes// /// fry// 19 1/32' 5/32' ANGLES 7' // 464' dWV 1 .1NI 02 x 2i' FL 46' x 93' 801' 35 1/16' -- 17 17/32' f 37 1 BETWEEN 19 1/32' 5/32'' ANGLES FL 46' x 93' FL 34' x 68' 691' SK 55 1/2' w W Ct LL O L1) (,-,N 1-.. V ' z W U 1- 0 ee w 1- z w U W Cti " (!) Q i 0 /////f/���r/./ loll//1, /A,//��. �A/j/. // 9' 5', END TO CENTER OF SCREED . w in LI 1-- W as U a: W City of Tukwila BUILD .'`=1 DIVISION WALK-IN SPECIFICATIONS 1/4" FOAMED PANELS ARE 4' EXTERIOR FINISH: AS SHOWN 22 GA 430 STAINLESS STEEL BALANCE 26 GA STUCCO GALVALUME EXTERIOR TOP (EXISTING CEILINGS) 26 GA STUCCO GALVALUME EXTERIOR TOP (NEW CEILINGS) 20 GA SMOOTH GALVANIZED WITH SUPPORT CHANNELS INTERIOR FINISH: WALLS 26 GA STUCCO GALVANIZED ' PPTD WHITE COOLER 1 CEILING' 26 GA STUCCO GALVANIZED PPTD WHITE FREEZER CEILING! 26 GA STUCCO GALVANIZED PPTD WHITE COOLER 2 CEILING' 26 GA STUCCO GALVANIZED PPTD WHITE NEW COOLER CEILING+ 26 GA STUCCO GALVANIZED PPTD WHITE NEW FREEZER CEILING 26 GA STUCCO GALVANIZED PPTD WHITE COOLER 1 4' VINYL FOAM SCREED W/ 5/8' TILE & GROUT FREEZER ,100 DIAMOND TREADPLATE W/ 5/8' TILE & GROUT COOLER 2 4' VINYL FOAM SCREED W/ 5/8" TILE & GROUT NEW COOLER - 4" VINYL FOAM SCREED W/ 5/8" TILE & GROUT NEW FREEZER ,100 DIAMOND TREADPLATE W/ 5/8' TILE & GROUT COOLER 1 - OD 8'-6 1/4"' ID 8'-1 5/8' FREEZER -' OD 8'-6 1/4" ID 7'-10 5/8" COOLER 2- OD 8'-6 1/4' ID 8'-1` 5/8" NEW COOLER - OD 8'-6 1/4" ID 8'-1 5/8" NEW FREEZER OD 8'-6 1/4' ID 7'-10 5/8" DOOR 08C1243A60056005 (EXISTING) 46x94,25DS 34x78 DR LH SCD CLR FRAME=22 430S/26GW PLUG=22 430S/26GW 115.-60-1/4,2 AMPS DOOR 08C1243B60056005 (EXISTING) 46x94,25DS`34x78 DR LH SCD CLR FRAME=22 430S/26GW PLUG=22 430S/26GW 115-60-1/4,2 AMPS DOOR 08C1243C05050505 (EXISTING) 46x94,25DS 34x78 DR LH RMP FZR FRAME=26GW/26GW PLUG=26GW/26GW 115-60-1/4,2 AMPS DOOR 299695D04050405 (NEW) 57,5x94,25DS 42x78 DR LH SCD CLR FRAME=GL/26GW PLUG=GL/26GW 115-60-1/0,4 AMPS DOOR 299695E05050505 (NEW) 69x94,25DS 42x78 DR RH RMP FZR FRAME=26GW/26GW PLUG=26GW/26GW 115-60-1/1.4 AMPS SEPARATE PEWIT REQUIRED FOR: ❑ Mechanical Er Electrical • Plumbing U4 Gas Piping FILE COPY 11/ 6,00 \ Permit ��. Plan` review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and conditions,is acknowledged: ACCESSORIES: EXISTING (1) LOT, CEILING SUPPORT, CEILINGS SPLIT ON PARTITION EXISTING (2) KICKPLATE ,063 TREAD 36"DR EXT EXISTING (2) KICKPLATE ,063 TREAD 36'DR INT EXISTING (2) VIEWPORT, 14X14 COOLER EXISTING (1) INTERIOR RAMP, ,34"X20" ,100 DIA TREAD EXISTING (5) LIGHTS, FLUORESCENT 48' W/❑UT BULBS NEW (6) KASON 1346 HINGE BRUSHED CHROME ADJUSTABLE (SPRING ASSTD) NEW (2) KASON 27C HANDLE BRUSHED CHROME NEW (2) KASON 1094 DOOR CLOSER BRUSHED CHROME NEW (2) 2' DIAL THERMOMETER NEW (2) SWITCH & PILOT LIGHT NEW (2) KASON 1803 LED DOOR LIGHT W/GLOBE, BULB & NIGHTLIGHT 120V NEW (2) STEEL REINFORCED DOOR JAMB NEW (2) SET OF 2 SLAM BRACES. NEW (1) KASON 1825 HEATED AIR VENT NEW (1) HEATER WIRE 2.5 WATT/FT NEW (1) 14 GA STAINLESS STEEL THRESHOLD NEW (1) INTERIOR RAMP 42x20 REFRIG: WATER COOLED / PRE -CHARGED 4" VINYL FOAM SCREED AND FLOOR PANEL LAYOUT EXISTING PANELS FROM ORDER 08C1243 DO NOT USE this dra ing for installation IMPORTANT NOTES: City of Tukwila BUILDING DIVISION REVISIONS No changes shan hn mride to the scope of work withO! prior approval of Tukwila 811i1cling Division NOTE: Revisions will rcquire plan submittal and may innide additional plan ri--2,riP,•:'.1 fee - 1) MANITOWOC RECOMMENDS A AINIMUM AIRFLOW AROUND THE WALK-IN OF 5 CFM PER 100 SQ, FT. OF WALL AREA TO MINIMIZE CONDENSATION, 'INDOOR \WALK-INS REQUIRE A 75°F AMBIENT AND 55% RELATIVE HUMIDITY OR LESS AROUND THE EXTERIOR OF THE WALK-IN." 2) WALK-IN CEILING IS NOT DESIGNED FOR FOOT TRAFFIC OR STORAGE, 3) GENERAL CONTRACTOR TO REFER TO DESIGN AND SPECIFICATIONS MANUAL FOR FLOOR DETAIL INFORMATION. 4) SPECIAL NOTE TO GENERAL CONTRACTOR AND SUBCONTRACTOR FOR QUARRY TILE OR CONCRETE WEARING FLOOR - THE SHEET METAL PANEL FACINGS MAY BE SUSCEPTABLE TO STAINING DUE TO EXCESSIVE MOISTURE CREATED BY THE HYDRATION OF CONCRETE TYPE MATERIALS, THEREFORE, IT IS ABSOLUTELY NECESSARY THAT EACH ROOM BE PROPERLY VENTILATED, ALSO NOTE THAT SPECIAL PRECAUTIONS MUST BE TAKEN WHEN USING MURIC ACID DUE TO EFFECTS HYDROCHLORIC ACID FUMES HAVE ON ALUMINUM AND STAINLESS STEEL MATERIALS, 5) THIS DRAWING IS FOR APPROVAL PURPOSES ONLY AND IS NOT TO BE USED FOR INSTALLATION OF THIS WALK-IN, AN "AS -BUILT" DRAWING IS PROVIDED WITH EACH SHIPPED WALK-IN. 6) THE FOAM PLASTIC INSULATION USED IN THIS PRODUCT COMPLIES TO IBC SECTION 2603 AS FOLLOWS! FLAME SPREAD RATING! 20 SMOKE DEVELOPED RATING! 450 FLASH IGNITION TEMPERATURE RATING! 915°F SPONTANEOUS IGNITION TEMPERATURE RATING! 950°F CONFORMS TO AEA STD 1995 44,0 17111216noN oar 40807 THIS DRAWING/ FILE IS THE PROPERTY OF MANITOWOC AND STORED IN AN ELECTRONIC DATA BASE. ANY ALTERATIONS CR ADDITIONS MUST BE APPROVED BY MANITOWOC ENGINEERING AND CHANGED IN SIGNED APPROVED PRINT ED APPROVED AS DRAWN = APPROVED AS NOTED # OF CHANGES = NOT APPROVED RESUBMIT HERMETIC (EXISTING) PC145MW 1-1/2hp R-22 208/230-60-3 9,3 AMPS L=33", W=25 1/2',H=18 3/4" LBS, =273 AM -130 EVAPORATOR 115-60-1 3,6 AMPS L=45. 5', W=12", H=15", LBS, =53 PUMP DOWN KIT SEMI -HERMETIC (EXISTING) PC204LW 2hp R -404A 208/230-60-3 6.8 AMPS L=43" W=23", H=19 1/4", LBS, =545 EL -090 EVAPORATOR 208/230-60-1 8,7 AMPS L=45. 5'1, W=12", H=15", LBS, =48 PUMP DOWN KIT HERMETIC (EXISTING) PC95MW lhp R-22 208/230-60-3 4,7 AMPS L=33", W=25 1/2',H=14 3/4" LBS.=244 AM -090 EVAPORATOR' 115-60-1 3,6 AMPS L=45, 5', W=12" H=15", LBS. =49 PUMP 'DOWN'` KIT SIGNED DATE PLEASE VERIFY WALL HEIGHTS, ALL DIMENSIONS AND METAL FINISHES BEFORE APPROVING DRAWING. REVIEWED FOR CODE COMPLIANCE APPROVED JUL 132010 ity of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA 2018 PERMIT CENTER • RESTAURANT CUSTOMER LJ 1-1 CY LJJ LJJ 00 CO • 299695-3 Lp 1-1 • Ld 5/15/2018 CHANGES PER CUSTOMER REQUEST CO 4/27/2018 CHANGES PER CUSTOMER REQUEST 4/17/2018 LO CHANGES PER CUSTOMER REQUEST REVISION