MECHANICAL PERMIT
2623049144
360 CORPORATE DR N BLDG 10
Project Name: CULINEX
Permit Number: M18-0051
Issue Date: 7/16/2018
Permit Expires On: 1/12/2019
Owner:
Name:
Address:
Contact Person:
Name:
Address:
Contractor:
Name:
Address:
License No:
Lender:
Name:
Address:
SOUTHCENTER CORPORATE SQUAR
635 ANDOVER PARK W #107 ,
TUKWILA, WA, 98188
JOHN SCHOFIELD
360 CORPORATE DR N , TUKWILA, WA,
98188
POLAR BEAR MECHANICAL INC
401 NE RAVENNA BL, SUITE 130 ,
SEATTLE, WA, 98115
POLARBM891PC
I 11
Phone: (206) 852-6102
Phone: (425) 967-5827
Expiration Date: 10/3/2019
DESCRIPTION OF WORK:
EXPANDING EXISTING COOLER
Valuation of Work: $19,200.00
Type of Work: REPLACEMENT
Fuel type: ELECT
Fees Collected: $464.01
Electrical Service Provided by:
Water District:
Sewer District:
Current Codes adopted by the City of Tukwila:
International Building Code Edition:
International Residential Code Edition:
International Mechanical Code Edition:
Uniform Plumbing Code Edition:
International Fuel Gas Code:
Permit Center Authorized Signature:
2015
2015
2015
2015
2015
National Electrical Code:
WA Cities Electrical Code:
WAC 296-46B:
WA State Energy Code:
2017
2017
2017
2015
L)i2L7-4
Date: --7, v p —i v
/
I hearby certify that I have read and examined this permit and know the same to be true and correct. All
provisions of law and ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this
development permitnd agree to the conditions attached to this permit.
Signature:
Print me:
Date7--/7-2e
This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if
the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
7: TO SCHEDULE ALL FIRE INSPECTIONS, CALL 206-575-4407.
4: Fire protection systems shall be maintained in accordance with the original installation standards for that
system. Required systems shall be extended, altered or augmented as necessary to maintain and continue
protection whenever the building is altered, remodeled or added to. Alterations to fire protection systems
shall be done in accordance with applicable standards. (IFC 901.4)(ENSURE ADEQUATE SPRINKLER
COVERAGE IN THE EXPANDED WALK-IN COOLER.)
2: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide. (NFPA 13-8.6.5.3.3)
1: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department
review and approval of drawings prior to installation or modification. New sprinkler systems and all
modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory
Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire
Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence
without approved drawings. (City Ordinance No. 2436).
3: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances
#2436 and #2437)
5: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply
approval of such condition or violation.
6: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention
Bureau at (206)575-4407.
8: Work shall be installed in accordance with the approved construction documents, and any changes made
during construction that are not in accordance with the approved construction documents shall be
resubmitted for approval.
9: All permits, inspection record card and approved construction documents shall be kept at the site of work
and shall be open to inspection by the Building Inspector until final inspection approval is granted.
10: All construction shall be done in conformance with the Washington State Building Code and the
Washington State Energy Code.
11: There shall be no occupancy of a building until final inspection has been completed and approved by
Tukwila building inspector. No exception.
12: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap
the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks,
wells, and other excavations. Final inspection approval will be determined by the building inspector based
on satisfactory completion of this requirement.
13: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the
City of Tukwila Building Department (206-431-3670).
14: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila
Permit Center.
15: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an
approval of, any violation of any of the provisions of the building code or of any other ordinances of the City
of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other
ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction
documents and other data shall not prevent the Building Official from requiring the correction of errors in
the construction documents and other data.
16: ***MECHANICAL PERMIT CONDITIONS***
17: All mechanical work shall be inspected and approved under
Permit Center (206/431-3670).
18: Manufacturers installation instructions shall be available on
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206) 438-9350
1400
0703
1800
0705
0701
FIRE FINAL
MECH EQUIP EFF
MECHANICAL FINAL
REFRIGERATION EQUIP
ROUGH -IN MECHANICAL
a separate permit
the job site at the
issued by the City of Tukwila
time of inspection.
/-
CITY OF TUKWIiA
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.TukwilaWA.gov
Mechanical Permit No.
Project No.
Date Application Accepted:
Date Application Expires:
'-t-t
10 -11-(
(For office use only)
MECHANICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**please print**
SITE LOCATION
King Co Assessor's Tax No.:
Site Address: 360 Corp. Dr. N Suite Number: Floor:
Tenant Name:
PROPERTY OWNER
Name: John Schofield
Name: CuliNex Ile
City: Tukwila State: WA Zip: 98188
Address: 360 Corp. Dr. N.
Email: john@culinex.biz
City: Tukwila State: WA
Zip: 98188
CONTACT PERSON — person receiving ail project
communication
Name: John Schofield
Address: 360 Corp. Dr. N.
City: Tukwila State: WA Zip: 98188
Phone: 206 852 6102 Fax:
Email: john@culinex.biz
New Tenant: ❑ Yes ..No
MECHANICAL CONTRACTOR INFORMATION
Company Name: Polar Bear Mechanical
Address: 401 N.E. Ravenna Blvd. #130
City: Seattle State: WA Zip: 98115
Phone: 206 419 8522 Fax:
Contr Reg No.: POLARBM891 PC Exp Date: 10-03-18
Tukwila Business License No.: BUS -0997559
Valuation of project (contractor's bid price): $ 19,200.00
Describe the scopse of work in deta
Use: Residential: New ❑ Replacement ❑
Commercial: New ❑ Replacement
Fuel Type: Electric
Gas ❑ Other:
H:\ Applications\Forms-Applications On Line\2016 Applications\Mechanical Permit Application Revised I.4-16.docx
Revised: January 2016
bh
Page 1 of 2
i 1
Indicate type of mechanical work being installed and the quantity below:
Unit Type
Qty
Furnace <100k btu
Residential, Nighttime
Furnace >100k btu
Industrial
Floor furnace
55 dB(A)
Suspended/wall/floor
mounted heater
57 dB(A)
Appliance vent
Commercial
Repair or addition to
heat/refrig/cooling
system
1
Air handling unit
65 dB(A)
<10,000 cfm
60 dB(A)
Unit Type
Qty
Air handling unit
Residential, Nighttime
>10,000 cfm
Industrial
Evaporator cooler
55 dB(A)
Ventilation fan
connected to single duct
57 dB(A)
Ventilation system
Commercial
Hood and duct
47 dB(A)
Incinerator — domestic
65 dB(A)
Incinerator —
conun/industrial
60 dB(A)
Unit Type
Qty'
Fire damper
Diffuser
Thermostat
Wood/gas stove
Emergency generator
Other mechanical
equipment
Boiler/Compressor
Qty
0-3 hp/100,000 btu
3-15 hp/500,000 btu
15-30 hp/1,000,000 btu
30-50 hp/1,750,000 btu
50+ hp/1,750,000 btu
Noise:
Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is
created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed.
For more details, see TMC 8.22
District of Sound
Producing Source
District of Receiving Property
Residential, Daytime*
Residential, Nighttime
Commercial
Industrial
Residential
55 dB(A)
45 dB(A)
57 dB(A)
60 dB(A)
Commercial
57 dB(A)
47 dB(A)
60 dB(A)
65 dB(A)
Industrial
60 dB(A)
50 dB(A)
65 dB(A)
70 dB(A)
*Daytime means 7AM-10PM, Monday through Friday and 8AM-10PM, Saturday, Sunday and State -recognized holidays.
A few sounds are exempt from the noise code, including:
• Warning devices;
• Construction and property maintenance during the daytime hours (7am-lOpm);
• Testing of backup generators during the day.
PERMIT APPLICATION NOTES -
Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the permit center to comply with current fee schedules.
Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing
and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING�W�`�THO� AG
Signature:
Date: 4-13-2018
Print Name: John Schofield Day Telephone: 206 852 6102
Mailing Address: 360 Corp. Dr. N. Tukwila WA 98188
City State Zip
H:\Applications\Forms-Applications On Line\2016 Applications\Mechanical Permit Application Revised 1-4-16.docx
Revised: January 2016
bh
Page 2 of 2
f '1
:ash •Register,Receip
City of Tukwila
DESCRIPTIONS ACCOUNT
PermitTRAK
QUANTITY
PAID
$464.01
M18-0051 Address: 360 CORPORATE DR N BLDG 10 Apn: 2623049144 $464.01
MECHANICAL $446.16
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
0.00
$33.15
PERMIT FEE
R000.322.100.00.00
0.00
$323.78
PLAN CHECK FEE
R000.322.102.00.00
0.00
$89.23
TECHNOLOGY FEE $17.85
TECHNOLOGY FEE R000.322.900.04.00 0.00 $17.85
TOTAL FEES PAID BY RECEIPT: R14243 $464.01
Date Paid: Friday, April 13, 2018
Paid By: CULINEX HOLDINGS LLC
Pay Method: CHECK 1092
Printed: Friday, April 13, 2018 10:11 AM 1 of 1
!SYSTEMS
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
M 1k' -o51
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188
Permit Inspection Request Line (206) 438-9350
(206) 431-3670
Project:
AL
Type of I spectipn:
Address:
Date Called:
Special Instructs • s:
UN -I
V�
1�
Date W nted:3
/�j
—� 7' ZOO
a.m.
p.m.
Requester.
Phone No:
Approved per applicable codes. Corrections required prior to approval.
COMMENT ••
/4 w
721'etri
Inspector: `i7 (0CS
9
Date
:9-17 oe
REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
1113-x51
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
Pro ect%l /
1, uL/
��ppe of Ins ec on:
pAf
FAV I—
Address:
bleb
^
edre b rw-c,
Special Instru tions:
Da" to Wanted:
7—/7—Z0/er 111,
?..3L
1 0
Requester
Vol
ecr
-F5;2- 61oZ
Approved per applica•le codes.
Corrections required prior to approval.
COMMENTS:
.2,,a,., * -
Inspector: `n Q
ri
Date
7./ zoo'
REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Btvd., Suite 100. Call to schedule reinspection.
INSPECTION NUMBER
INSPECTION WORD
Retain a copy With permit
��► i �- o65-
PERMIT
ss
PERMIT NUMBERS
CITY OF TUKWILA FIRE DEPARTMENT
206-575-4407
Project:
C ohvl-eX
7
Type of Inspection:
S
r ,-�/i4
Address: ,--
Suite #: 5(9 t)
(71/sfert4
Hood & Duct:
Cgntact Person:
/`/
Monitor:
Special Instructions:
Pre -Fire:
Phone No.:
pproved per applicable codes.
Corrections required prior to approval.
COMMENTS:
‹ipy
fpv4t,-
Needs Shift Inspection:
7
Sprinklers: 7
Fire Alarm:
Hood & Duct:
Monitor:
Pre -Fire:
Permits:
Occupancy Type:
g
Inspector: i2-77,2_-;---4-
Date: 7/, b <
Hrs.;
$100.00 -REINSPECTION FEE REQUIRED. You will receive an invoice•from
the City of Tukwila Finance Department. CaII to schedule a reinspection.
Billing Address
Attn:
Company Name:
Address:
City:
State:
Zip:
Word/Inspection Record Form.Doc
3/14/14
T.F.D. Form F.P. 113
April 25, 2018
City of Tukwila
Department of Community Development
JOHN SCHOFIELD
360 CORPORATE DR N
TUKWILA, WA 98188
RE: Correction Letter # 1
MECHANICAL Permit Application Number M 18-0051
CULINEX - 360 CORPORATE DR N
Dear JOHN SCHOFIELD,
Allan Ekberg, Mayor
Jack Pace, Director
This letter is to inform you of corrections that must be addressed before your development permit can be approved. All
correction requests from each department must be addressed at the same time and reflected on your drawings. I have
enclosed comments from the following departments:
BUILDING - M DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these
comments.
• (GENERAL INFORMATION NOTE)
PLAN SUBMITTALS: (Min. size 11x17 to a preferably maximum size of 24x36; all sheets shall be the same
size; larger sizes may be negotiable. "New revised" plan sheets shall be the same size sheets as those previously
submitted.)
"STAMP AND SIGNATURES" (If applicable) For Engineers: "Every page of a plan set must contain the
seal/stamp, signature of the licensee(s) who prepared or who had direct supervision over the preparation of the
work, and date of signature. Specifications that are prepared by or under the direct supervision of a licensee shall
contain the seal/stamp, signature of the licensee and the date of signature. If the "specifications" prepared by a
licensee are a portion of a bound specification document that contains specifications other than that of an
engineering or land surveying nature, the licensee need only seal/stamp that portion or portions of the documents
for which the licensee is responsible." It shall not be required to have each page of "specifications" (calculations) to
be stamped and signed; Front page only will be sufficient (WAC 196-23-010 & 196-23-020). Architects: "date"
only not required (WAC 308-12-081).
(BUILDING REVIEW NOTES)
1. Provide drawings that are clear and drawn to scale. Reduces size sheets shall not be accepted. Clearly mark or
cloud where the work is located. Provide manufacturers information of the mechanical relocated or added. Show
how the mechanical equipment shall be seismically anchored. Include any other relevant information.
Note: Contingent on response to these corrections, further plan review may request for additional corrections.
Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other
documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be
resubmitted with the appropriate revision block.
In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have
enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail
or by a messenger service.
6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665
Sincerely,
Bill Rambo
Permit Technician
File No. M18-0051
6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665
1
ANT COORD COPY
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: M18-0051
PROJECT NAME: CULINEX
DATE: 04/13/18
SITE ADDRESS: 360 CORPORATE DR N
X Original Plan Submittal Revision # before Permit Issued
Response to Correction Letter #
Revision # after Permit Issued
DEPARTMENTS:
A 3 Coq
Building Division
Public Works
Fire Prevention
Structural
Planning Division
Permit Coordinator
PRELIMINARY REVIEW:
Not Applicable n
(no approval/review required)
DATE: 04/17/18
Structural Review Required
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS: DUE DATE: 05/15/18
Approved
❑ Approved with Conditions
Corrections Required Denied
(corrections entered in Reviews) (ie: Zoning Issues)
n
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only 11 1
CORRECTION LETTER MAILED: 14
Departments issued corrections: Bldg ► Fire D Ping ❑ PW 0 Staff Initials:
____WL
12/18/2013
r
PER iIT COORD COPY
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: M18-0051
PROJECT NAME: CULINEX
DATE: 07/11/18
SITE ADDRESS: 360 CORPORATE DR N
Original Plan Submittal Revision # before Permit Issued
X Response to Correction Letter # 1 Revision # after Permit Issued
DEPARTMENTS:
Building Division
Public Works
n
Fire Prevention
Structural
n
Planning Division
UPermit Coordinator
n
•
PRELIMINARY REVIEW:
Not Applicable n
(no approval/review required)
DATE: 07/12/18
Structural Review Required
REVIEWER'S INITIALS: DATE:
n
APPROVALS OR CORRECTIONS: DUE DATE: 08/09/18
Approved
Corrections Required
nApproved with Conditions n
n Denied ❑
(corrections entered in Reviews) (ie: Zoning Issues)
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials:
12/18/2013
Date:
� 1
City of Tukwila
REVISION
SUBMITTAL
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Web site: http://www.TukwilaWA.gov
Revision submittals must be submitted in person at the Permit Center.
Revisions will not be accepted through the mail, fax, etc.
Plan Check/Permit Number:% 9 ✓ oo %'
❑ Response to Incomplete Letter #
Response to Correction Letter # )
❑ Revision # after Permit is Is/sued
❑ Revision requested by a City Building Inspector or Plans Examiner
❑ Deferred Submittal #
Project Name:///1/e / /6//r':
Project Address: b2 7//
Contact Person /01,/ _c,.,Ortfq� Phone Number2067% g5�
Summary of Revision:
RECEIVED
CITU OF TUIKWILA
JUL 1 1 2018
PERMIT CNTEI
Sheet Number(s):
"Cloud" or highlight all areas of revision including date of revisi
Received at the City of Tukwila Permit Center by:
Entered in TRAKiT on�" [ � %-t
W:1Permtt Center\Templates\Forms \Revision Submittal Formdoc
Revised. August 2015
POLAR BEAR MECHANICAL INCA
lime Espanol Contact
Safety & Health Claims & Insurance
A Washington State Department of
�% Labor & Industries
Page 1 of 2
Search L&I
A-7. Index Help My T.&I
Workplace Rights Trades & Licensing
POLAR BEAR MECHANICAL INC
Owner or tradesperson
Principals
BELCHER, GARRY DEWAYNE, PRESIDENT
Doing business as
POLAR BEAR MECHANICAL INC
WA UBI No.
603 145 986
401 NE RAVENNA BLVD 130
SEATTLE, WA 98115
425-967-5827
KING County
Business type
Corporation
License
Verify the contractor's active registration / license / certification (depending on trade) and any past violations.
Construction Contractor Active.
Meets current requirements.
License specialties
GENERAL
License no.
POLARBM891PC
Effective — expiration
10/03/2011-10/03/2019
Bond
Western Surety Co
Bond account no.
62501547
$12,000.00
Received by L&I Effective date
10/09/2015 09/12/2015
Expiration date
Until Canceled
Bond history
Insurance
Endurance American Specialty 1 $1,000,000.00
Policy no.
dci00549-00
Received by L&I Effective date
01/09/2018 01/08/2018
Expiration date
01/08/2019
Mid -Century Ins Co $1,000,000.00
Policy no.
605133486
Received by L&I Effective date
09/08/2017 09/12/2016
Expiration date
Help us improve
https://secure.lni.wa.gov/verify/Detail.aspx?UBI=603145986&LIC=POLARBM891 PC&SAW= 7/16/2018
POLAR BEAR MECHANICAL INC
09/12/2018
Insurance history
Savings
No savings accounts during the previous 6 year period.
Lawsuits against tie bond or savings
No lawsuits against the bond or savings accounts during the previous 6 year period.
L&I Tax debts
No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts
may be recorded by other agencies.
License Violations
No license violations during the previous 6 year period.
Workers' comp
Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums.
This company has multiple workers' comp accounts.
Active accounts
L&l Account ID
231,624-01
................................
Doing business as
POLAR BEAR MECHANICAL INC
Estimated workers reported
Quarter 1 of Year X018 "31 to 50 Workers"
L&I account contact
T5 / BETTY WHALIN (360)902-5137 - Email: VABE235@Ini.wa.gov
Track this contractor 0
Account is current.
Public Works Strikes and Debarments
Verify the contractor is eligible to perform work on public works projects.
Contractor Strikes
No strikes have bean issued against this contractor.
Contractors not al:owed to bid
No debarments have been issued against this contractor.
Workplace safety and health
No inspections during the previous 6 year period.
Page 2 of 2
("Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington.
Help us improve
https://secure.lni. wa.gov/verify/Detail.aspx?UBI=603145986&LIC=POLARBM891PC& SAW= 7/16/2018
1'
8'-10
17'-4"
8'-4"
COOLER 1
8'-6„
E3 0"
FREEZER
S0ti00C80C S0t+0JM£t"2TO80
m
O
SOb002808
CO
0
S0t'002808
GOG0tr087t,0
S01703/1£421380 S01'002808
1
.21
.g9£
.917
21XE2
00
CL 46.5' x 106'
08C1243CA04040405
(15' HIGH)
AM -130
50� --71\--
M cn
0
0
0
0
32.5'
,9b .21
50'
3ESCENT LIG
-J
L.
ao
LTJ
03 .--
M ,W
ww
08C1243CB040405 o ro
CL
46' x 106' cp--�"--29�'--�-
C
F
CL 46,5' x 102'
48' 08c1243CD04040405
(16' HIGH)
S'
EL-090
48' FLUORESCENT LIGHT
M08C1243CE04040505/
30P CL 46' x 102' 316'-
1 LOCK PANE S FROM THIS SIDE
Z0
16.75'
08C1243WC0505
7l/118C 243C05050505
51' d
17,25' (12'
0
0 O
0
0
0
o`
N
CO
03
v
in a
34DR 08C1243WD0505
0
29r1'-- ,. °'
521"
.A.
0
FLUORESCENT LIGH
CL 23' x $08'
CL 46' x 106'
08C1243CB040405
M
0
CL 46' x 208'\N
✓/,( 23'
808106005
58'
4
243A60056005 F11,5' 23'
0
0
0
Ul
0
Fr
`a
1/40
CO
� -1 12')
48' OLUORESCEN LIGHT I D 1
�3
L_L_ -1
08C1243CF040405 �l
CL 46' x 102'
48' FLUORESCENT LIGHT %�I
-411
to r -STD DFF
(Y,
-t r
STD M
28P
808006005
T
1
FJ7-- 48�''' �-
---13r
' 34DR $ 08C` 4 VA600505
SOM
i»
CL 46' x 2518i
/
801"
z
4 ,24386005600534DR $
atilt
L1 t
L
EXISTING WALLS ARE 22 GA 430 STAINLESS STEEL
ch_ 0 F=z---- 9"
F
�1/
�' / CL 34.5' x 208'
7
O r %
ru
46?
,,,,,;46e
0' .r_aJ% ,aril i�S1.O 0 0 - .6 /4', 7.
i ink
il."'
0
21r
cm
NOTE: THIS IS AN EXISTING
CORNER S0 EXTERIOR IS 22
GA 430 STAINLESS STEEL
-21e
CL 46' x 208'
CL 46' x 208'
34,5'
808906005
69?
0
0
0
N
CO
CO
ic
ON
Apr
d
cu
cu
COOL
O
Cm cN
ER 2
/ - 51" MIN.
�coc
0
SOt,01S89S cv
///l4 - WV /4//�/���J/. �/�/���//i /r���./�/7/Ce7 %/14.45 i2'
808200405 808200405 308306005 ,1
NOTE: THIS IS AN EXISTING
CORNER SO EXTERIOR IS 22
GA 430 STAINLESS STEEL
.
CL 34' x 81,5'
Cr'
• 12'V /.44,9VW'///
5'-0"
5'-8"
30830
405
dCLEAR-
-
d'.
NEW COOLER
NEW FREEZER
16'8
9' 3"
11'-8'1
PANELS
-vp/001
(v(-frArq
81'S)
1
17'-4"
CENTER TO END OF ` SCREED
8'6" - 8'-
104'
20' IIV-
3e
4- 4- 4-- I-
46e
58'
35 1/16'
117 17/32'
37 1
BETWEEN
j
55 1/2'
FLM08C1243FA0404040521
35'x104'
z
FLM08C1243F20405040521
36,5' x 104'
_.•- 341'-►
IN1RA'P 34X20
X570 5221
-+►-34'-*►
co
51'
35'-�•--
521'
o►
-11
� 7/fes// /// fry//
19 1/32'
5/32'
ANGLES
7'
//
464'
dWV 1 .1NI 02 x 2i'
FL 46' x 93'
801'
35 1/16' --
17 17/32' f
37 1
BETWEEN
19 1/32'
5/32''
ANGLES
FL 46' x 93'
FL 34' x 68'
691'
SK 55 1/2'
w
W
Ct
LL
O
L1)
(,-,N
1-..
V ' z
W
U
1-
0
ee
w
1-
z
w
U
W
Cti " (!) Q
i
0
/////f/���r/./ loll//1, /A,//��. �A/j/.
//
9' 5',
END TO CENTER OF SCREED
. w
in LI
1--
W
as
U
a:
W
City of Tukwila
BUILD .'`=1 DIVISION
WALK-IN SPECIFICATIONS
1/4"
FOAMED PANELS ARE 4'
EXTERIOR FINISH:
AS SHOWN 22 GA 430 STAINLESS STEEL
BALANCE 26 GA STUCCO GALVALUME
EXTERIOR TOP (EXISTING CEILINGS) 26 GA STUCCO GALVALUME
EXTERIOR TOP (NEW CEILINGS) 20 GA SMOOTH GALVANIZED
WITH SUPPORT CHANNELS
INTERIOR FINISH:
WALLS 26 GA STUCCO GALVANIZED ' PPTD WHITE
COOLER 1 CEILING' 26 GA STUCCO GALVANIZED PPTD WHITE
FREEZER CEILING! 26 GA STUCCO GALVANIZED PPTD WHITE
COOLER 2 CEILING' 26 GA STUCCO GALVANIZED PPTD WHITE
NEW COOLER CEILING+ 26 GA STUCCO GALVANIZED PPTD WHITE
NEW FREEZER CEILING 26 GA STUCCO GALVANIZED PPTD WHITE
COOLER 1 4' VINYL FOAM SCREED W/ 5/8' TILE & GROUT
FREEZER ,100 DIAMOND TREADPLATE W/ 5/8' TILE & GROUT
COOLER 2 4' VINYL FOAM SCREED W/ 5/8" TILE & GROUT
NEW COOLER - 4" VINYL FOAM SCREED W/ 5/8" TILE & GROUT
NEW FREEZER ,100 DIAMOND TREADPLATE W/ 5/8' TILE & GROUT
COOLER 1 - OD 8'-6 1/4"' ID 8'-1 5/8'
FREEZER -' OD 8'-6 1/4" ID 7'-10 5/8"
COOLER 2- OD 8'-6 1/4' ID 8'-1` 5/8"
NEW COOLER - OD 8'-6 1/4" ID 8'-1 5/8"
NEW FREEZER OD 8'-6 1/4' ID 7'-10 5/8"
DOOR 08C1243A60056005 (EXISTING)
46x94,25DS 34x78 DR LH SCD CLR
FRAME=22 430S/26GW PLUG=22 430S/26GW
115.-60-1/4,2 AMPS
DOOR 08C1243B60056005 (EXISTING)
46x94,25DS`34x78 DR LH SCD CLR
FRAME=22 430S/26GW PLUG=22 430S/26GW
115-60-1/4,2 AMPS
DOOR 08C1243C05050505 (EXISTING)
46x94,25DS 34x78 DR LH RMP FZR
FRAME=26GW/26GW PLUG=26GW/26GW
115-60-1/4,2 AMPS
DOOR 299695D04050405 (NEW)
57,5x94,25DS 42x78 DR LH SCD CLR
FRAME=GL/26GW PLUG=GL/26GW
115-60-1/0,4 AMPS
DOOR 299695E05050505 (NEW)
69x94,25DS 42x78 DR RH RMP FZR
FRAME=26GW/26GW PLUG=26GW/26GW
115-60-1/1.4 AMPS
SEPARATE PEWIT
REQUIRED FOR:
❑ Mechanical
Er Electrical
• Plumbing
U4 Gas Piping
FILE COPY
11/ 6,00 \
Permit ��.
Plan` review approval is subject to errors and omissions.
Approval of construction documents does not authorize
the violation of any adopted code or ordinance. Receipt
of approved Field Copy and conditions,is acknowledged:
ACCESSORIES:
EXISTING (1) LOT, CEILING SUPPORT, CEILINGS SPLIT ON PARTITION
EXISTING (2) KICKPLATE ,063 TREAD 36"DR EXT
EXISTING (2) KICKPLATE ,063 TREAD 36'DR INT
EXISTING (2) VIEWPORT, 14X14 COOLER
EXISTING (1) INTERIOR RAMP, ,34"X20" ,100 DIA TREAD
EXISTING (5) LIGHTS, FLUORESCENT 48' W/❑UT BULBS
NEW (6) KASON 1346 HINGE BRUSHED CHROME ADJUSTABLE (SPRING ASSTD)
NEW (2) KASON 27C HANDLE BRUSHED CHROME
NEW (2) KASON 1094 DOOR CLOSER BRUSHED CHROME
NEW (2) 2' DIAL THERMOMETER
NEW (2) SWITCH & PILOT LIGHT
NEW (2) KASON 1803 LED DOOR LIGHT W/GLOBE, BULB & NIGHTLIGHT 120V
NEW (2) STEEL REINFORCED DOOR JAMB
NEW (2) SET OF 2 SLAM BRACES.
NEW (1) KASON 1825 HEATED AIR VENT
NEW (1) HEATER WIRE 2.5 WATT/FT
NEW (1) 14 GA STAINLESS STEEL THRESHOLD
NEW (1) INTERIOR RAMP 42x20
REFRIG: WATER COOLED / PRE -CHARGED
4" VINYL FOAM SCREED AND FLOOR PANEL LAYOUT
EXISTING PANELS FROM ORDER 08C1243
DO NOT USE this dra ing for installation
IMPORTANT NOTES:
City of Tukwila
BUILDING DIVISION
REVISIONS
No changes shan hn mride to the scope
of work withO! prior approval of
Tukwila 811i1cling Division
NOTE: Revisions will rcquire plan submittal
and may innide additional plan ri--2,riP,•:'.1 fee -
1) MANITOWOC RECOMMENDS A AINIMUM AIRFLOW AROUND THE WALK-IN OF
5 CFM PER 100 SQ, FT. OF WALL AREA TO MINIMIZE CONDENSATION,
'INDOOR \WALK-INS REQUIRE A 75°F AMBIENT AND 55% RELATIVE
HUMIDITY OR LESS AROUND THE EXTERIOR OF THE WALK-IN."
2) WALK-IN CEILING IS NOT DESIGNED FOR FOOT TRAFFIC OR STORAGE,
3) GENERAL CONTRACTOR TO REFER TO DESIGN AND SPECIFICATIONS
MANUAL FOR FLOOR DETAIL INFORMATION.
4) SPECIAL NOTE TO GENERAL CONTRACTOR AND SUBCONTRACTOR FOR
QUARRY TILE OR CONCRETE WEARING FLOOR - THE SHEET METAL
PANEL FACINGS MAY BE SUSCEPTABLE TO STAINING DUE TO EXCESSIVE
MOISTURE CREATED BY THE HYDRATION OF CONCRETE TYPE MATERIALS,
THEREFORE, IT IS ABSOLUTELY NECESSARY THAT EACH ROOM BE
PROPERLY VENTILATED, ALSO NOTE THAT SPECIAL PRECAUTIONS MUST
BE TAKEN WHEN USING MURIC ACID DUE TO EFFECTS HYDROCHLORIC
ACID FUMES HAVE ON ALUMINUM AND STAINLESS STEEL MATERIALS,
5) THIS DRAWING IS FOR APPROVAL PURPOSES ONLY AND IS NOT TO BE
USED FOR INSTALLATION OF THIS WALK-IN, AN "AS -BUILT"
DRAWING IS PROVIDED WITH EACH SHIPPED WALK-IN.
6) THE FOAM PLASTIC INSULATION USED IN THIS PRODUCT COMPLIES TO
IBC SECTION 2603 AS FOLLOWS!
FLAME SPREAD RATING! 20
SMOKE DEVELOPED RATING! 450
FLASH IGNITION TEMPERATURE RATING! 915°F
SPONTANEOUS IGNITION TEMPERATURE RATING! 950°F
CONFORMS TO
AEA STD 1995 44,0
17111216noN oar 40807
THIS DRAWING/
FILE IS THE
PROPERTY OF
MANITOWOC AND
STORED IN AN
ELECTRONIC
DATA BASE. ANY
ALTERATIONS
CR ADDITIONS
MUST BE
APPROVED BY
MANITOWOC
ENGINEERING AND
CHANGED IN
SIGNED APPROVED PRINT
ED APPROVED AS DRAWN
= APPROVED AS NOTED
# OF CHANGES
= NOT APPROVED RESUBMIT
HERMETIC (EXISTING)
PC145MW 1-1/2hp R-22 208/230-60-3 9,3 AMPS
L=33", W=25 1/2',H=18 3/4" LBS, =273
AM -130 EVAPORATOR 115-60-1 3,6 AMPS
L=45. 5', W=12", H=15", LBS, =53
PUMP DOWN KIT
SEMI -HERMETIC (EXISTING)
PC204LW 2hp R -404A 208/230-60-3 6.8 AMPS
L=43" W=23", H=19 1/4", LBS, =545
EL -090 EVAPORATOR 208/230-60-1 8,7 AMPS
L=45. 5'1, W=12", H=15", LBS, =48
PUMP DOWN KIT
HERMETIC (EXISTING)
PC95MW lhp R-22 208/230-60-3 4,7 AMPS
L=33", W=25 1/2',H=14 3/4" LBS.=244
AM -090 EVAPORATOR' 115-60-1 3,6 AMPS
L=45, 5', W=12" H=15", LBS. =49
PUMP 'DOWN'` KIT
SIGNED
DATE
PLEASE VERIFY WALL HEIGHTS, ALL
DIMENSIONS AND METAL FINISHES
BEFORE APPROVING DRAWING.
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JUL 132010
ity of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF TUKWILA
2018
PERMIT CENTER
•
RESTAURANT
CUSTOMER
LJ
1-1
CY
LJJ
LJJ
00
CO
•
299695-3
Lp
1-1
•
Ld
5/15/2018
CHANGES PER CUSTOMER REQUEST
CO
4/27/2018
CHANGES PER CUSTOMER REQUEST
4/17/2018
LO
CHANGES PER CUSTOMER REQUEST
REVISION