Loading...
HomeMy WebLinkAboutPermit M18-0055 - BOEING #9-053 - DOGHOUSEBOEING #9-053 DOGHOUSE 9725 E MARGINAL WAY S BLDG 9-053 MI 8-0055 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 5624200990 Permit Number: M18-0055 9725 E MARGINAL WAY S BLDG 9-053 Issue Date: 5/17/2018 Permit Expires On: 11/13/2018 Project Name: BOEING #9-053 - DOGHOUSE Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: DESIMONE TRUST BOEING 1201 THIRD AVE STE #5010 C/O BNY MELLON NA, SEATTLE, WA, 98101 CONNIE HARDIN 4600 S 134 PL , SEATTLE, WA, 98168 HOLADAY PARKS INC 4600 S 134 PL, SEATTLE, WA, 98168 HO LADP1379N0 Phone: (206) 250-4530 Phone: (206) 248-9700 Expiration Date: 9/3/2019 DESCRIPTION OF WORK: INSTALL MINI SPLIT HVAC SYSTEM IN THE NEW ROOFTOP STRUCTURE; ASSOCIATED REFRIGERANT PIPING, CONDENSATE PIPING, AND DUCTWORK Valuation of Work: $90,000.00 Type of Work: Fuel type: Fees Collected: $1,376.40 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: Date: 2017 2017 2017 2015 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or loc... aws regulI ing construction or the performance of work. I am authorized to sign and obtain this developm nt p:mit an a:r:t- to the nditions attached to this permit. Signature: Print Name: Datev — v This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector: until final inspection approval is granted. 3: Readily accessible access to roof mounted equipment is required. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 8: ***MECHANICAL PERMIT CONDITIONS*** 9: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 10: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL CITY OF TUKWILA Community Development Department Permit Center 6300 Southeenter Blvd, Suite 100 Tu104414 WA 98188 C CAL PE anical Permit No.1V116/ OD No. • 1 /2 - Date Application Accepted: L4 n1.1i )ate Application irts: V V) (For offiee e onin T APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION r's Tax No.: S102. -L1 7,0 D4I umber: Floor New Tenant 0 ....Yes 0 ..No CONTACT PERSON — person recciving all project communication Na flt 1 Address; S (•e' EmailbDn State:AX Fax:2042 ct OR INIORMAT1ON Cornpany Name: Address: Liteloo s • . Statekx Zip toe Fax Phone:Fax20k ZSDLiS31) ibt, Z.S4 6 Contr Reg No.: 14a...4.tprs_ri 06.xp Date:41_ ici Tukwila Business License No.: Reside:Alt& Clectrir —.. Replacement 0 • Petit Type Furnace <100k btu •.- Qty Furnace >100k btu Floor furnace Suspendediwall/ mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10 000 cfm nit Type „ Air h,,f dling tmit Residential., Nighttime >10,000 clin lndustrial Evaporator cooler 55 dB(A) Ventilation fan connected to single duct . 57 dB(A) Ventilation system Commercial Hood and chict 47 I t: (A) Irwin — doiucstic t t Incinerator — oonunrmdustrial 60 dB(A) Unit Typ Qty Fire dumper Residential., Nighttime Diffuser lndustrial Thermostat 55 dB(A) Woodl vt stove . 57 dB(A) Emergency generator Commercial Other mechanical equipment 47 I t: (A) VI it) i_ t t Boiler/Compressor Qty 0-3 hp100,000 btu 3.15 hp/500,000 btu 15-30 hp/1.000,000 btu 30-50 hp/1,750,000 btu 50-t- hp/I,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on Som where the sound is created and where the sound is beard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For morc details, see TMC 8.22 District of Sound Producing Source DistiictofReceivingProperty Residential, Daytitne Residential., Nighttime Commercial lndustrial Residential 55 dB(A) 45 dB(A) . 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 I t: (A) 60 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-10PM, Monday through Fri d 8AM-1OPM, Saturday. Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: • Warning devices; • Construction and property maintenance during the daytime hours (7am-l0pm); • Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications fir which no permit is issued within 180 days ibilowing the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). 1 HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BIJILDIN Signature: Print Name: 0 1],9AGENT: Address:LI to cr.-) S 1:71.11rZ4WPi=.1.Mr- ',Z;11.4 Day Telephone: D City Zip P2 of .2 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $1,376.40 M18-0055 Address: 9725 E MARGINAL WAY S BLDG 9-053 Apn: 5624200990 $1,376.40 Credit Card Fee $40.09 Credit Card Fee R000.369.908.00.00 0.00 $40.09 MECHANICAL $1,284.91 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $994.78 PLAN CHECK FEE R000.322.102.00.00 0.00 $256.98 TECHNOLOGY FEE $51.40 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R14316 R000.322.900.04.00 0.00 $51.40 $1,376.40 Date Paid: Monday, April 23, 2018 Paid By: CONNIE HARDIN Pay Method: CREDIT CARD 00662G Printed: Monday, April 23, 2018 12:54 PM 1 of 1 CPPIP.fSYSTEMS INSPECTION NO. INSPECTION RECORD Retain a copy with permit IttS PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: ZOO dip Ci- as3 Type of Inspec ion: Iii •Avel-C, Address: g724 6 Date Called: 4 Special I`,n/gstruc�tio/J�nf�s.� 3 Date Wanted: 4-44 �/��j a.m. Requester: Phone No: a1¢ /- p [ !i E/ pproved peraPPlicable codes. II Corrections required prior to approval. COMMENTS: mcatoil.4 CTLs -r-t,.J,m-t- 4 ID Inspector: Date: 2.7/ zz)," REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100, Call to schedule reinspection. 4/1/2019 City of Tukwila Department of Community Development CONNIE HARDIN 4600 S 134 PL SEATTLE, WA 98168 RE: Permit No. M18-0055 BOEING #9-053 - DOGHOUSE 9725 E MARGINAL WAY S Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 5/13/2019. Based on the above, you are hereby advised to: 1) CaII the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 5/13/2019, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, WA"" � / Kandace Nichols Permit Technician File No: M18-0055 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 / 1 City of Tukwila Allan Ekberg, Mayor Department of Community Development - Jack Pace, Director October 26, 2018 Connie Hardin Holaday Parks Inc. 4600 S 134th PI Tukwila, WA 98168 RE: Request for Extension #1 Permit Number M18-0055 Dear Ms. Hardin, This letter is in response to your written request for an extension to Permit M18-0055. The Building Official, Jerry Hight, has reviewed your letter and considered your request to extend the above referenced permit. It has been determined that the City of Tukwila Building Division will be granting an extension to the permit through May 13, 2019. If you should have any questions, please contact our office at (206) 431-3670. Sincerely, Bill Rambo Permit Technician File: Permit No. M18-0055 Tukwila City Hall • 6200 Southcenter Boulevard • Tukwila, WA 98188 • 206-433-1800 • Website: TukwilaWA.gov / Bill Rambo From: Connie Hardin <connieh@holadayparks.com> Sent: Tuesday, October 9, 2018 7:52 AM To: Bill Rambo Cc: Derek Hart Subject: Extension request M18-0055 Attachments: 2018-05-17 Mech M18-0055.pdf Hi Bill. We would like to extend attached permit M18-0055 due to equipment delays. Thank you. Connie Hardin Holaday Parks CAUTION: This email originated from outside the City of Tukwila network. Please DO NOT open attachments or click links from an unknown or suspicious origin. Request for Extension # _ Current Expiration Date: :,1:71:3 -13 Extension Request: Approved for J_ Denied (provide explanation) days Signature/Initials 1 RECEIVED CITY OF TUKWILA OCT 092018 PERMIT CENTER 10/1/2018 r� City of Tukwila Department of Community Development CONNIE HARDIN 4600 S 134 PL SEATTLE, WA 98168 RE: Permit No. M18-0055 BOEING #9-053 - DOGHOUSE 9725 E MARGINAL WAY S Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 11/13/2018. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 11/13/2018, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, 1U(),\ achelle Ripley Permit Technician File No: M18-0055 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 J'ERMIT COORD COPY 7. ) PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M18-0055 DATE: 04/26/18 PROJECT NAME: BOEING #9-053 - DOGHOUSE SITE ADDRESS: 9725 E MARGINAL WAY S BLDG 9-053 X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: ,-S mac. ad fl Building Division Public Works ❑ Fire Prevention Structural Planning Division ❑ Permit Coordinator El PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 04/26/18 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 05/24/18 Approved ❑ Approved with Conditions Corrections Required ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 HOLADAY PARKS INC fra Washington State Department of . i... Labor & Industries Home Espanol Contact Safety & Health Claims & Insurance l Search L&I Page 1 of 3 1-Z Index Help Ni 1.&I Workplace Rights Trades & Licensing HOLADAY PARKS INC Owner or tradesperson Principals BECK, DAVID CARL, PRESIDENT CONNELL, DANIEL A, PRESIDENT GIRI, BIJIT, PRESIDENT PIZZEY, GRACE K, VICE PRESIDENT FREEL, JERRY LEE, VICE PRESIDENT PARKS, GERALD T JR, PRESIDENT (End: 08/12/2015) NAILON, JUNE ANNETTE, VICE PRESIDENT (End: 08/12/2015) O'CONNOR, BONNY K, SECRETARY (End: 08/12/2015) BECK, DAVID CLARENCE, TREASURER (End: 08/12/2015) VAN DER VEEN, ERIC M, VICE PRESIDENT (End: 08/14/2013) PIZZEY, GRACE KATHERINE, VICE PRESIDENT (End: 08/14/2013) VAN DER VEEN, JULIE ELIZABETH, MEMBER (End: 08/14/2013) CONNELL, DANIEL AARON, MEMBER (End: 08/14/2013) GIRI, BUIT, MEMBER (End: 08/14/2013) KIEL, RINALD HOWARD, MEMBER (End: 08/14/2013) WHITMYRE, CHRISTIAN, MEMBER (End: 08/14/2013) NELSON, MICHAEL, SECRETARY (End: 11/04/2010) PARKS, DAVID L, TREASURER (End: 11/04/2010) TALBOT, PAUL, TREASURER (End: 11/04/2010) Doing business as HOLADAY PARKS INC 4600 S 134TH PL SEATTLE, WA 98168 206-248-9700 KING County WA UBI No. Business type 578 004 089 Corporation Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=578004089&LIC=HOLADPI379N0&SAW= 5/17/2018 HOLADAY PARKS INC Governing persons DAVID BECK DAN CONNELL, JERRY FREEL; BIJIT GIRI; GRACE PIZZEY; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. HOLADPI379NO Effective — expiration 01/21/1983— 09/03/2019 Bond LIBERTY MUTUAL INS CO Bond account no. 23000452 Active. Meets current requirements. $12,000.00 Received by L&I Effective date 08/23/2002 09/01/2002 Expiration date Until Canceled Insurance Charter Oak Fire Ins Co Policy no. DTCO1 F465357C0F17 $1,000,000.00 Received by L&I Effective date 10/31/2017 11/01/2017 Expiration date 11/01/2018 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date onworkers' comp premiums. L&I Account ID 177,231-00 Doing business as HOLADAY PARKS INC Estimated workers reported Quarter 1 of Year 2018 "Greater than 100 Workers" L&I account contact T4 / CASSANDRA SMITH (360)902-5632 - Email: SMCA235@Ini.wa.gov Account is current. Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Page 2 of 3 Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=578004089&LIC=HOLADPI379N0&SAW= 5/17/2018 BO 9/25 SORT N B AS U v 0\S OF SPCTO\ WLLAVFTTF VFR DARCFL PROJECT SITE FROM DOWNTOWN SEATTLE AIR MUSEUM BOEING FIELD OX BO :RIDGE ACCESS RD 599 TUKWILA EAST MARGINAL WAY 99 CORPORATE PARK FROM KENT Sc AUBURN FROM SEATTLE—TACOMA AIRPORT DEVELOPME\TAL CE\TES NO SCALE 0 D\ AR AS P 4, TOW D A\ \S v N 9 A N D 23 G CO. VBFR 562/2 A 5J U Sfll ON 98 \ORTI \Tv, WAS 0-0990 AREA MA D 3UILD1\G A»HSS: 9725 EAST NAKI\AL WAY SO.,TH TU<WILA, WASHI\GTO\ PROJECT SITE 3UILDI \G 9-53 LOCATIO\ NO SCALE A\CF 0 08 4 FAST, 9-53 SUMMARY LAND USE CODE BUILDING CODES CODE S OCCUPANCY GROUP CONSTRUCTION TYPE FLOOR AREAS: BUILDING FOOTPRINT BUILDING GROSS FIRST FLOOR SECOND FLOOR THIRD FLOOR PENTHOUSE BUILDING HEIGHT STORIES OCCUPANT LOAD: HANDICAPPED REQUIREMENTS FIRE PROTECTION SEISMIC DESIGN CATEGORY VMARV FILE COPY Permit No. 1/1 10'00 Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Fieipyr\artd cofitionis acknowledged: TUKWILA MUNICIPAL CODE CHAPTER 18, MIC/H ZONE MAXIMUM HEIGHT 125 FT. 2015 IEBC, R0151 FC, 2015 IBC AS AMENDED, 2015 WASHINGTON STATE ENERGY CODE AND CITY OF TUKWILLA TITLE 16; WAC 51-11 BARRIER FREE CODE AS ADOPTED OR AMENDED, AND COMPLIANCE WITH THE CITY OF TUKWILLA ZONING CODES GROUP B TYPE II—B (ORIGINAL PERMIT AS TYPE II, UBC) SEE ALLOWABLE AREA ANALYSIS, SHEET A1B 54,821 (EXISTING) 97,901 (EXISTING) 54,821 (EXISTING) 43,080 (EXISTING) 880 (PROPOSED) 44 ft (EXISTING); 71'-9"± (PROPOSED — PER IBC 1510.2, HEIGHT GREATER THAN 18 FEET ABOVE ROOF DECK CONSIDERED AN ADDITIONAL STORY); ALLOWABLE = 75 FT. TABLE 504.3 2 (EXISTING); 3 (PROPOSED — PER IBC 1510.2, HEIGHT GREATER THAN 18 FEET ABOVE ROOF DECK CONSIDERED AN ADDITIONAL STORY) NO CHANGES NON APPLICABLE: IBC1104.4, EXCEPTION 1 FULLY AUTOMATIC, F/S CLASS 1 SPRINKLERS THROUGHOUT D SCOPE OF WORK • • THIS PROJECT WILL CONSTRUCT A NEW 1 STORY DOGHOUSE STRUCTURE (APPROXIMATELY 880 SQUARE FEET) TO BE LOCATED ON THE ROOF OF BUILDING 9-53. RELOCATE NUMEROUS SYSTEM COMPONENTS FROM BUILDING 18-43 AND 18-61 TO THE NEW DOGHOUSE. PROVIDE CONNECTION OF RELOCATED SYSTEM COMPONENTS TO THE VARIOUS LABS IN BUILDING 9-53 ESTIMATED CONSTRUCTION COST: $1,000,000.00 SEE SHEET 9-53—TWRS2 FOR SPECIAL INSPECTION. SEE SHEET 9-53—TWRA1 B FOR CODE ANALYSIS. SEE SHEET 9-53—TWRA1 FOR EXITING ANALYSIS. DEFERRED SUBMITTALS: By: Date: -fl--1 City of Tukwila BUILDING DIVISION ISSUE FOR CONSTRUCTION MARCH 9, 2018 RDAS t chances shat be made to the sect work without prior approval of T.:s` wqa Building Division. NOTE: Rarsions will require a new pan submittal i and may include additional plan reviewfees Wectmaktd Weezcalcd Cii•Gas City of Tukrala BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED MAY 16 2018 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA APR 2 3 2018 PERMIT CENTER SITTS & HILL ENGINEERS, INC. CIVIL • STRUCTURAL • SURVEYING 4815 CENTER STREET I TACOMA, WA. 98409 PHONE: (253) 474-9449 I FAX: (253) 474-9449 http://www.sitts-hili-engineers.com/ Project No.: 18000 Project Mgr.: BKL Pro j. Engineer: BRL Pro j. Drafter: SLM SYM REVISION BY I APPROVED DATE SYM REVISION BY APPROVED DATE RELOCATE DOGHOUSE TO BUILDING 9-53 33447-05 SITTS BRL 03.09.18 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN S. McCarthy CHECKED B. Labrecque DATE 08.09.17 08.09.17 SUBTITLE COVER SHEET CURRENT REVISION 33447-05 SYMBOL DATE 03.09.18 APPROVED BY DEPT. DATE ENGINEER B. Labrecque CHECKED B. Leslie APPROVED 08.09.17 08.09.17 APPROVED TITLE ARCHITECTURAL RELOCATE DOGHOUSE TO BUILDING 9-53 BUILDING 09-53 DEV. CENTER. WA SHEET TWRAO JOB NO. 33447-05 COMP NO. DWG NO. 09 053—TWRAO 3/4" 1" PVC CONDENSATE DRAIN 2'X2' PLYWOOD PAINTED BLACK I I "DN WL BALL VALVE a 3/4" CD 01 r'" CW > cI 561 A 2"VDN 2"VDN CI FS -1 (9) TYP "2» V > 1Y2"V DN 3/4" COND DRAIN '4" RL BTW ROOF JOISTS ABOVE DUCTS SLOPE ©1/2"/FT MATCHLINE—FOR CONTINUATION SEE SHT. 2M110 0 FUTURE A/C pf- UNIT 1 /2"CW 1 2M111 1M521 4" RL UP TO RD -1 v—� �- FUTURE A/C UNIT FLR MTD A/C UNIT 2x1 1/2" V DN 2" V 1/2" TRAP PRIMER 3" VTR 563 (THRU GRD PLANE) 2 1/2" V 1/2" TRAP PRIMER V 2" V 2" V IN CLG SPACE (TYP) 3/4" CD V 21F; 572 563 21 C7 4" RL BELOW SUPPLY/RETURN DUCTS & ABOVE CLG V F.5 1 /2" CW� AC2E5 AC2E5 10—TON-- -.6 1 --3/4" CD 4" RL DN 4" RL UP TO RD -1 4" RL DN 1/2" TRAP PRIMER 1 1/2" V >�1 1/2" V 27C7 1/2" TRAP PRIMER 3/4" CD DRAIN ON SUNKEN FLR (TYP) SECO\D FLOC) SCALE: 1/8' = '-0" PLUM > 26C7 V. 23C7 569 573- 31\G PLA\ 25C7 1/2 TRAP PRIMER -e7 3/4" 4" RL DN & /UP TO RD -1 4 1 /2" DRAIN FROM AUTOMATIC AIR VENT DISCHARGE LINE WITH CHECK VALVE TO FLOOR SINK SELF CONTAINED CONDENSATE PUMP CP—X MAY BE NEXT TO A/C UNIT BELOW RAISED FLOOR OR ATTACHED TO CLG HUNG UNITS W/BRACKET 113 'LIEBERT MDL #UH2O0C MATCHLINE—FOR II II CONTINUATION SEE SHT. 2M112 /' A/C UNIT FLOOR / OR CLG MOUNTED COOLING COIL DRAIN PAN BELOW COOLING COIL FLOOR TYPICAL PUNP DETAIL SCALE: NONE PROFESSIONAL STAMP & SIGNATURE APPLIES TO WORK WITHIN THE CLOUDED REVISION AREAS ONLY AS INDICATED i Cg F8 C5 2 LEGE GE\E D SAL \OTES 1. HVAC REFERENCE DRAWINGS (SHEET METAL) 1M10, 1M11, AND 1M12. 2. SEE ALSO A/C UNIT NOTES, SHEET M103. 3. TRAP PRIMER VALVE IN CLG SPACE W/THREE OPENING DISTRIBUTION UNIT. RUN 1/2" COPPER DISCHARGE LINES DOWN WALL AND ON SUNKEN FLR TO EACH FLOOR SINK (FS -1). (9) TYPICAL. 4. CW PIPING PRESSURE RATINGS: PROVIDE PIPE, TUBING, FITTINGS, ACCESSORIES, AND OTHER COMPONENTS WITH MINIMUM PRESSURE RATING OF 150 PSIG. TUBING (PIPE): ASTM B88 TYPE L COPPER WATER TUBE, HARD DRAWN. FITTINGS: WROUGHT COPPER SOLDER FITTINGS AND SCREWED ADAPTERS, ANSI B16.22. CAST COPPER ALLOY SOLDER JOINT FITTINGS AND SCREWED ADAPTERS, ANSI B16.18. USE OF T—DRILL FITTINGS IS NOT PERMITTED. UNIONS: WROUGHT COPPER SOLDER JOINT UNIONS, ANSI B16.22. CAST COPPER ALLOY SOLDER JOINT FITTINGS, ANSI B16.18. THREADED JOINT COMPOUND: TEFLON TAPE. SOLDER: 95 PERCENT TIN, 5 PERCENT ANTIMONY SOLDER, ASTM B 32 HARRIS "BRIDGIT" ACCEPTABLE. LACO FLUX OR SIMILAR NOT PERMITTED. VALVES: BALL: APOLLO 77C_100 OR 77C_200 SERIES FULL PORT BALL VALVE, SOLID BALL, 600 PSIG CWP, 150 PSIG SWP, BRONZE BODY, CHROME PLATED BALL AND STEM, SOLDER ENDS OR SCREWED, TEFLON SEAT AND SEAL. PROVIDE STEM EXTENSION FOR USE IN INSULATED PIPING. DIELECTRIC UNIONS: PROVIDE AT EACH JOINT BETWEEN DISSIMILAR METALS. 2 INCHES AND SMALLER: DIELECTRIC UNIONS RATED AT 250 PSIG AT 180 DEGREES F CONFORMING TO CONDENSATE DRAIN PIPING COPPER DRAINAGE TUBE: TYPE DWV, ASTM B306. FITTINGS: 1. TYPE DWV WROUGHT COPPER DRAINAGE FITTINGS, ANSI B16.29. 2. TYPE DWV CAST COPPER ALLOY DRAINAGE FITTINGS, ANSI B16.23. EFE.K\CE Th�AWI\GS CO\ SRUCTIO\ NOTES ROUTE CONDENSATE LINE UP TO DOGHOUSE TIGHT TO COLUMN. ASBESTOS NOTIFICATION A GOOD FAITH SURVEY OF THE BUILDING HAS BEEN CONDUCTED AND NO ASBESTOS CONTAINING MATERIAL WAS DISCOVERED WITHIN THIS BUILDING. FSi consulting engineers Seattle, Washington Solutions & Service riNICv-wooss � o REVIEWED FOR CODE COMPLIANCE APPROVED MAY 16 2010 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA APR 2 3 2018 PERMIT CENTER ISSUED FOR CONSTRUCTION MARCH 05, 2018 2M113 2M110 2M114 8 2M111 2M112 4 0 2 4 16 SCALE: 1/8" = 1'-0" SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE - CONVERSION FROM MYLAR TO CAD CCSI 12.10.00 A B C D PROVIDE AIR DROP J # 711552-00 DESIGN COMPRESSED AIR DROPS DEVELOPMENT LAB - RECORD SET RELOCATE DOG HOUSE TO BUILDING 9-53 10971894 12787 33447-05 DMV M.WONG WH FSi RWS GV AWL 08.03.10 02.14.14 03.05.18 Q� BOE/ ”® o'— 03.05.18 SWIM ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN TGT DATE 8.30.85 CHECKED LMM 8.30.85 SUBTITLE SECOND FLOOR PLUMBING PLAN CURRENT REVISION SYMBOL 33447-05 DATE 03.05.18 ENGINEER CHECKED APPROVED APPROVED TITLE RELOCATE DOG HOUSE TO BUILDING 9-53 MECHANICAL MASTER BUILDING 9-53 COL. A—G/4-8 DEV. CENTER, WA SHEET 2M111 JOB NO. 10971894 COMP NO. DWG NO. 9-53-2M1 1 GE\EAL \OTES C0\SRUC11O\ \OTES COORDINATE PIPING PENETRATIONS WITH ARCHITECTURAL. LOCATE CONDENSING UNIT ON EXISTING PLATFORM. COORDINATE LOCATION WITH EXISTING EQUIPMENT AND MAINTAIN ALL MANUFACTURER RECOMMENDED CLEARANCES. ATTACH TO PLATFORM PER MANUFACTURER'S INSTRUCTIONS. �EFE�E \CE NAWI\GS REVIEWED FOR CODE COMPLIANCE APPROVED MAY 162018 City of Tukwila BUILDING DIVISION HVAC DI\G SLA\ SCALE: 3/8" = 1'-0" RECEIVED CITY OF TUKWILA APR 232018 PERMIT CENTER PROFESSIONAL STAMP & SIGNATURE APPLIES TO WORK WITHIN THE CLOUDED REVISION AREAS ONLY AS INDICATED REVISION APPROVED REVISION APPROVED ORIG RELOCATE DOG HOUSE TO BUILDING 9-53 33447-05 03.05.18 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY FSi consulting engineers Seattle, Washington Solutions & Service DRAWN DGK CHECKED GLS ENGINEER GLS CHECKED AWL ISSUED FOR CONSTRUCTION MARCH 05, 2018 <EY PLA\ SCALE: N.T.S. 0 1' 2' 4' 6' 8' SCALE: 3/8" = 1'-0" FEET ('(1\`6.00 55 DATE SUBTITLE 01.19.18 01.19.18 01.19.18 01.19.18 HVAC PIPING PLAN CURRENT REVISION 33447-05 SYMBOL° 03.05.18 RELOCATE DOG HOUSE TO BUILDING 9-53 APPROVED APPROVED MECHANICAL MASTER BUILDING 9-53 COL. C—D/5-6 RFM61 DEV. CENTER, WA JOB NO. DWG NO. 09-053—RFM61 .CS OOF PLUV31\G PLA\ SCALE: 3/8" = 1'-0" PROFESSIONAL STAMP & SIGNATURE APPLIES TO WORK WITHIN THE CLOUDED REVISION AREAS ONLY AS INDICATED FSi consulting engineers Seattle, Washington Solutions & Service 6) GE\EAL \OTES 1. CONDENSATE DRAIN PIPING COPPER DRAINAGE TUBE: TYPE DWV, ASTM B306. FITTINGS: 1. TYPE DWV WROUGHT COPPER DRAINAGE FITTINGS, ANSI B16.29. 2. TYPE DWV CAST COPPER ALLOY DRAINAGE FITTINGS, ANSI B16.23. CO\S-RUCTION \OTES ROUTE CONDENSATE LINE TO FLOOR DRAIN BELOW. COORDINATE PIPING PENETRATIONS WITH ARCHITECTURAL. EEEE\CE DAWI\GS REVIEWED FOR CODE COMPLIANCE APPROVED MAY 162013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA APR 232018 PERMIT CENTER ISSUED FOR CONSTRUCTION MARCH 05, 2018 0 1' 2' SCALE: 3/8" = 1'-0" 4' 6' \(‘-00 55 8' FEET 4 SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ORIG RELOCATE DOG HOUSE TO BUILDING 9-53 33447-05 FSi AWL 03.05.18 03.05.18 SICKED ACCEPTABILITY THIS DESIGN AND/OR .SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN DGK CHECKED GLS DATE 01.19.18 01.19.18 SUBTITLE ROOF PLUMBING PLAN CURRENT REVISION SYMBOL 33447-05 O IG DATE 03.05.18 ENGINEER GLS CHECKED AWL APPROVED APPROVED 01.19.18 01.19.18 TITLE RELOCATE DOG HOUSE TO BUILDING 9-53 MECHANICAL MASTER BUILDING 9-53 COL. C—D/5-6 DEV. CENTER, WA SHEET RFMIIO JOB NO. COMP NO. DWG NO. 09-053—RFM 110 yam minairk* Not, 0116. ‘414% 11144 itist\b, 1111 ‘,111‘11§6X‘16, _11111Wiii 111111111111W1011bNIIIIMU1111111111e110ftZinift, 110.116, liebk Nibk lib \II 'iliillf-,ONOZ4MININIMKINNIOZNIMONAMIhMONNMISCIII 'IWO+ 0111Wall•IMININC,TaMI\NiiM\WIMILMMININMNIIMiWNLVINN w.: N lk 1 141 II\ 11\,. \L. 1\a. 1.‘A\4\11hbin -141N\k‘ 61,k\h, 116111111211111111611111..11111111111111. FRE HOTECTIO\ SCALE 3/8" = 1'-0" PLA\ PROFESSIONAL STAMP & SIGNATURE APPLIES TO WORK WITHIN THE CLOUDED REVISION AREAS ONLY AS INDICATED FSi consulting engineers Seattle, Washington Solutions & Service 6 LEGE \D GE\ ORDINARY HAZARD GROUP 2 HAL \OTES CO\STUCTIO\ OTES PROVIDE A PREACTION CLOSED HEAD FIRE SUPPRESSION SYSTEM CONFORMING TO ALL REQUIREMENTS FOR A GROUP 2 HAZARD OCCUPANCY AS DEFINED BY NFPA13. SYSTEM TO BE ENGAGED BY BUILDING 9-53 MAIN FIRE ALARM PANEL. COORDINATE WITH ELECTRICAL. ROUTE DRY SPRINKLER MAIN FROM SPRINKLER RISER LOCATED IN 3RD FLOOR MECHANICAL ROOM. EFRE\CE ��AWI\GS REVIEWED FOR CODE COMPLIANCE APPROVED MAY 162010 City of Tukwila BUILDING DIVISION ISSUED FOR CONSTRUCTION MARCH 05, 2018 RECEIVED 0 1' 2' CITY OF T U K W I L A SCALE: 3/8" _ APR 2 3 2018 PERMIT CENTER 4' 1'-O" 6' 8' FEET 5 SYM REVISION ORIG RELOCATE DOG HOUSE TO BUILDING 9-53 33447-05 BY APPROVED FSi AWL DATE SYM REVISION BY APPROVED DATE 03.05.18 BOE/NG° o'— 03.05.18 mut ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN DGK DATE 01.19.18 CHECKED GLS ENGINEER GLS CHECKED AWL APPROVED APPROVED 01.19.18 01.19.18 01.19.18 SUBTITLE TITLE FIRE PROTECTION PLAN RELOCATE DOG HOUSE TO BUILDING 9-53 MECHANICAL MASTER BUILDING 9-53 COL. C—D/5-6 DEV. CENTER, WA CURRENT REVISION SYMBOL 33447-05 0 sic DATE 03.05.18 SHEET RFM261 JOB NO. COMP NO. DWG NO. 09-053—RFM 261 INDGO HEAT PUvP SC -ED LE CALLOUT LOCATION SERVICE UNIT CONFIGURATION INDOOR FAN COOLING [3] HEATING CAPACITY (BTUH) FILTER TYPE BASIS OF DESIGN NOTES TYPE MARK CFM ESP (IN WC) [1] [2] MOTOR HP NOMINAL CAPACITY (TONS) [4] TOTAL COOLING (BTUH) SENSIBLE COOLING (BTUH) MANUFACTURER MODEL AC 1 WORKSTATION 15C2 DOGHOUSE WALL MOUNTED 635 N/A 0.125 2 24000 18000 26500 MERV-8 DAIKIN FXAQ24 [5] [7] AC 2 WORKSTATION 15C3 DOGHOUSE WALL MOUNTED 635 N/A 0.125 2 24000 18000 26500 MERV-8 DAIKIN FXAQ24 [5] [7] AC 3 DOGHOUSE 15C1 DOGHOUSE DUCTED 1000 .75 0.5 2.5 30000 23800 34000 MERV-8 DAIKIN FXMQ30 [5] [6] AC 4 DOGHOUSE 15C1 DOGHOUSE DUCTED 1000 .75 0.5 2.5 30000 23800 34000 MERV-8 DAIKIN FXMQ30 [5] [6] SCHEDULE NOTES: 1 STATIC PRESSURE EXTERNAL TO UNIT 2: INCLUDES ALLOWANCE FOR FILTER LOADING 3AT 95 DEG F OUTDOOR AIR DRYBULB TEMPERATURE 4 NOMINAL TONNAGE INCLUDED FOR REFERENCE ONLY - DO NOT USE FOR FINAL SIZING OF EQUIPMENT 5- PROVIDE WITH INTERNAL CONDENSATE PUMP 6PROVIDE WITH MERV 8 FILTER 7- INCLUDE WASHABLE FILTER OUT:00 HEAT PUV1P SCHEDULE CALLOUT LOCATION SERVICE REFRIGERANT COOLING HEATING COMPRESSOR CONDENSER FANS BASIS OF DESIGN NOTES TYPE MARK NOMINAL CAPACITY (TONS) [1] TOTAL COOLING CAP. (MBH) EER [2] HEATING CAPACITY (MBH) COP [3] TYPE QTY QTY MANUFACTURER MODEL HP 1 DOGHOUSE 15C1 DOGHOUSE R410A 8 90 13.0 108 2.9 SCROLL 2 2 DAIKIN RXYQ96TYDN LAT (DEG F) SCHEDULE NOTES: [1] NOMINAL TONNAGE INCLUDED FOR REFERENCE ONLY — DO NOT USE FOR FINAL SIZING OF EQUIPMENT. [2] MINIMUM AHRI EFFICIENCY AS SCHEDULED. [3] COP RATED AT OUTDOOR AIR TEMPERATURE OF 17°F. E\EGY EC0VE VE\TILATO SCHEDULE CALLOUT LOCATION SERVICE MIN OSA "U" (CFM) [2][7] MIN OSA "0" (CFM) [2][7] SUPPLY FAN [5] EXHAUST [5] FILTER HEAT RECOVERY BASIS OF DESIGN NOTES TYPE MARK FAN TYPE DRIVE TYPE MAX CFM [1] E.S.P. (IN WC) [3] [4] QTY MOTOR FAN TYPE DRIVE TYPE MAX CFM [1] E.S.P. (IN WC) [3] [4] QTY MOTOR TYPE MAX VEL (FPM) TYPE WINTER SUMMER MANUFACTURER MODEL HP HP EAT (DEG F) LAT (DEG F) EFF EAT (DEG F) LAT (DEG F) EFF ERV 1 ROOF DOGHOUSE 150 250 FC DIRECT 250 0.25 1 1/2 FC DIRECT 225 0.25 1 1/2 MERV8 450 FIXED MEMBRANE 21 56 63 82 77 40 DAIKIN VAM300 [1] [2] [6] SCHEDULE NOTES: 1 WITH UNIT AT MAXIMUM CONDITIONS 2OUTSIDE AIR WITH QUANITITY WITH DAMPER AT MINIMUM POSITION AND UNIT AT MAXIMUM CONDITION. 3STATIC PRESSURE EXTERNAL TO UNIT 4 INCLUDES ALLOWANCE FOR FILTER LOADING 5MAXIMUM ALLOWABLE MOTOR BRAKEHORSEPOWER AT MAX FLOW AND ESP PER FAN MOTOR 6PROVIDE WITH MERV 8 FILTER 7 U = UNOCCUPIED SCHEDULE, 0 = OCCUPIED SCHEDULE. AR TENI\AL SC-EDLLE CALLOUT AIR TERMINAL DESCRIPTION AIRFLOW CAPACITY LIMITS (CFM) NOMINAL SIZE NECK DIMENSIONS MAX NC MAX TSP DROP (IN. W.G.) MATERIAL OPD FINISH BASIS OF DESIGN NOTES MAXIMUM MINIMUM LENGTH WIDTH FOR RECTANGULAR MANUFACTURER MODEL LENGTH WIDTH SG -1 SIDE MOUNTED ADJUSTABLE SINGLE DEFLECTION SUPPLY GRILLE 100 0 8 8 6 6 20 0.028 STEEL YES #26 WHITE TITUS 301 RL [1] SG -2 SIDE MOUNTED ADJUSTABLE SINGLE DEFLECTION SUPPLY GRILLE 500 350 20 8 18 6 30 0.117 STEEL YES #26 WHITE TITUS 301 RL [2] RG -1 SIDE MOUNTED RETURN GRILLE 100 0 8 8 6 6 20 0.018 STEEL YES #26 WHITE TITUS 350 RL RG -2 SIDE MOUNTED RETURN GRILLE 200 100 10 10 8 8 20 0.032 STEEL YES #26 WHITE TITUS 350 RL SCHEDULE NOTES: [1] SET BLADES TO 45' DEFLECTION. L2 SET BLADES TO 0' DEFLECTION. PROFESSIONAL STAMP & SIGNATURE APPLIES TO WORK WITHIN THE CLOUDED REVISION AREAS ONLY AS INDICATED FSi consulting engineers Seattle, Washington Solutions & Service ISSUED FOR CONSTRUCTION MARCH 05, 2018 REVIEWED FOR CODE COMPLIANCE APPROVED MAY 16 2018 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA APR 2 3 2018 PERMIT CENTER 6 SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ORIG RELOCATE DOG HOUSE TO BUILDING 9-53 33447-05 FSi AWL 03.05.18 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN DGK CHECKED GLS DATE SUBTITLE 01.19.18 01.19.18 EQUIPMENT SCHEDULE CURRENT REVISION SYMBOL 33447-05 ORI G DATE 03.05.18 ENGINEER GLS CHECKED AWL APPROVED APPROVED 01.19.18 01.19.18 TITLE RELOCATE DOG HOUSE TO BUILDING 9-53 MECHANICAL MASTER BUILDING 9-53 COL. DEV. CENTER. WA SHEET TWRMIA JOB NO. COMP NO. DWG NO. 09-053—TWRM1A i 7 10x6 10x6 V\ 12x10 RG -2 175 CFM 8"0 6"0 10" 0 .�_ 6"0 SG -2 500 CFM 16x12 12x101 SG -2 500 CFM 6"0 8"0 1— 12x10 \ / SG -2 l/ 500 CFM 6"0 6"0 16x12 12x10 EG -1 50 CFM SG -1 50 CFM SG -1 50 CFM i S1 2 500 CFM PROFESSIONAL STAMP & SIGNATURE APPLIES TO WORK WITHIN THE CLOUDED REVISION AREAS ONLY AS INDICATED FSi consulting engineers Seattle, Washington Solutions & Service GE\EAL \OTES 1. PROVIDE POST CONSTRUCTION COMMISSIONING AND COMPLETION REQUIREMENTS IN ACCORDANCE WITH THE WASHINGTON STATE ENERGY CODE 2015 EDITION, SECTION C408 AND ACCORDING WITH THE CONTRACT DOCUMENTS. SEE SPECIFICATION SECTIONS 23 05 00, 23 08 00 AND ALL OTHER APPLICABLE SPECIFICATION SECTIONS. 2. BALANCE ALL HVAC SYSTEMS IN ACCORDANCE WITH THE WASHINGTON STATE ENERGY CODE 2015 EDITION, GENERALLY ACCEPTED ENGINEERING STANDARDS AND IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. SEE SPECIFICATION SECTION 23 05 93 AND ALL OTHER APPLICABLE SPECIFICATION SECTIONS. 3. PROVIDE CONTROLS IN ACCORDANCE WITH THE WASHINGTON STATE ENERGY CODE, SECTION C403.2.4 AND IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. SEE TEMPERATURE CONTROL SPECIFICATION SECTIONS AND ALL OTHER APPLICABLE SPECIFICATION SECTIONS. 4. SEE FOR ICD 705 DUCT PENETRATION DETAIL. TWRM500I TWRM 11 C3\SRUCTIO\ \OTES PROVIDE SOUND LINED Z SHAPED DUCT PER TEMPEST REQUIREMENTS. PROVIDE MINIMUM REQUIRED MAINTENANCE CLEARANCE FOR ACCESS AROUND UNIT. PROVIDE LOW LEAK FIRE SMOKE DAMPER. PROVIDE 6"x8" ACCESS DOOR IN DUCT WITH HASPLOCK. PLATE ACCESSIBLE FOR INSPECTIONS AND REPLACING THE FUSIBLE LINK AT DAMPER. PROVIDE NON—METALLIC COUPLER AND DUCT WALL PENETRATION PER ICD ROOM CONSTRUCTION DETAILS PROVIDED BY THE CERTIFIED TEMPEST TECHNICAL AUTHORITY. 6> PROVIDE T—STAT INTERLOCKED WITH AC -3 AND AC -4. PROVIDE SOUND LINED DUCT. PROVIDE BIRD SCREEN AND WALL CAP ON DUCT OPENING. PROVIDE DIELECTRIC BREAK AT WALL PENETRATION. EFEH\CE DRAWI\GS re'° 55 REVIEVED FOR CODE COMPLIANCE APPROVED MAY 162013 City of Tukwila BUILDING DIVISION ISSUED FOR CONSTRUCTION MARCH 05, 2018 NMI 0 1' 2' 4' SCALE: 3/8" = 1RtCEIVED CITY OF TUKWILA APR 2 3 2018 PERMIT CENTER 6' 8' FEET 7 SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ORIG RELOCATE DOG HOUSE TO BUILDING 9-53 33447-05 FSI AWL 03.05.18 BOE/NGm W. L 4 0 DRAWN ACCEPTABILITY DGK THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE 01.19.18 CHECKED GLS ENGINEER DATE GLS CHECKED AWL APPROVED 03.05.18 SNEED 01.19.18 SUBTITLE HVAC DUCTWORK PLAN CURRENT REVISION SYMBOL 33447-05 0 IG DATE 03.05.18 APPROVED 01.19.18 01.19.18 TITLE RELOCATE DOG HOUSE TO BUILDING 9-53 MECHANICAL MASTER BUILDING 9-53 COL. C—D/5-6 DEV. CENTER, WA SHEET TWRMII JOB NO. COMP NO. DWG NO. 09-053—TWRM11 — —7/ \A HVAC PIPI\G PLA\ SCALE: 3/8" = 1'-0" PROFESSIONAL STAMP & SIGNATURE APPLIES TO WORK WITHIN THE CLOUDED REVISION AREAS ONLY AS INDICATED FSi consulting engineers Seattle, Washington Solutions & Service GE \EAL \OTES 1. SEE FOR ICD 705 PIPE PENETRATION DETAIL. TWRM500 TWRM61 CO\STUCTIO\ OTES REFRIGERANT PIPING LOCATED WITHIN TEMPEST ROOM TO BE GROUNDED TO COMMON GROUND BAR LOCATED WITHIN TEMPEST ENCLOSURE. COORDINATE WITH ELECTRICAL. INSTALL GROUNDING AND WALL PENETRATION PER ICD ROOM CONSTRUCTION DETAILS PROVIDED BY THE CERTIFIED TEMPEST TECHNICAL AUTHORITY. EFHE\CE DRAWI\ S REVIEWED FOR CODE COMPLIANCE APPROVED MAY 162018 City of Tukwila BUILDING DIVISION ISSUED FOR CONSTRUCTION MARCH 05, 2018 O wrwmaNum 0 1' 2'— OF TUKWILA 8' SCALE: 3/8" = 1'-0 FEET APR 2 3 2018 PERMIT CENTER 8 SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ORIG RELOCATE DOG HOUSE TO BUILDING 9-53 33447-05 FSI AWL 03.05.18 Q� BOE/NGm o'— 03.05.18 SIGNED ACCEPTABILITY THIS DESIGN AND/OR SPECIRCATION IS APPROVED APPROVED BY DEPT. DATE DRAWN DGK CHECKED GLS DATE 01.19.18 01.19.18 SUBTITLE HVAC PIPING PLAN CURRENT REVISION 33447-05 SYMBOL^ sic DATE 03.05.18 ENGINEER GLS CHECKED AWL APPROVED APPROVED 01.19.18 01.19.18 TITLE RELOCATE DOG HOUSE TO BUILDING 9-53 MECHANICAL MASTER BUILDING 9-53 COL. C—D/5-6 DEV. CENTER, WA SHEET TWRM61 JOB NO. COMP NO. DWG NO. 09-053—TWRM61 i '\ PROFESSIONAL STAMP & SIGNATURE APPLIES TO WORK WITHIN THE CLOUDED REVISION AREAS ONLY AS INDICATED • FSi consulting engineers Seattle, Washington Solutions & Service CO GE\ PAL \OTES 1. SEE FOR ICD 705 PIPE PENETRATION DETAIL. TWRM500 TWRM111 2. CONDENSATE DRAIN PIPING CO COPPER DRAINAGE TUBE: TYPE DWV, ASTM 8306. FITTINGS: 1. TYPE DWV WROUGHT COPPER DRAINAGE FITTINGS, ANSI B16.29. 2. TYPE DWV CAST COPPER ALLOY DRAINAGE FITTINGS, ANSI B16.23. \ST UCTIO\ \OTES ROUTE CONDENSATE DRAIN PIPING TO DRAIN LOCATED ON SECOND FLOOR. COORDINATE PENETRATION LOCATION WITH MANUFACTURER. INSTALL GROUNDING AT COPPER TUBING AND WALL PENETRATION PER ICD ROOM CONSTRUCTION DETAILS PROVIDED BY THE CERTIFIED TEMPEST TECHNICAL AUTHORITY. ETRE\CE NAWI\GS REVIEWED FOR CODE COMPLIANCE APPROVED MAY 16 2016 City of Tukwila BUILDING DIVISION ISSUED FOR CONSTRUCTION MARCH 05, 2018 vf1\5‹ • 55 0 1' 2' 4' 6' 8' SCALE: 3/8" = 1'-0" RECEIVED FEET CITY OF TUKWILA APR 232018 PERMIT CENTER 9 SYM ORIG REVISION RELOCATE DOG HOUSE TO BUILDING 9-53 33447-05 BY APPROVED FSi AWL DATE 03.05.18 SYM REVISION BY APPROVED DATE Q�BOE/NG° ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN DGK CHECKED GLS ENGINEER GLS AWL CHECKED APPROVED APPROVED DATE SUBTITLE 01,19.18 01.19.18 01.19.18 01.19.18 PLUMBING PLAN CURRENT REVISION SYMB°1-0 IG 33447-05 DATE 03.05.18 TITLE RELOCATE DOG HOUSE TO BUILDING 9-53 MECHANICAL MASTER BUILDING 9-53 COL. C—D/5-6 DEV. CENTER, WA SHEET TWRM111 JOB NO. COMP NO. DWG NO. 09-053—TWRM111 FIDE POTECTIO SCALE 3/8" = 1'-0" PLA\ PROFESSIONAL STAMP & SIGNATURE APPLIES TO WORK WITHIN THE CLOUDED REVISION AREAS ONLY AS INDICATED FSi consulting engineers Seattle, Washington Solutions & Service LEGEND rA GE\E ORDINARY HAZARD GROUP 2 SAL \OTES 1. SEE FOR ICD 705 PIPE PENETRATION DETAIL. TWRM500 TWRM261 10 CO\STUCTIO\ \OTES PROVIDE A PREACTION CLOSED HEAD FIRE SUPPRESSION SYSTEM CONFORMING TO ALL REQUIREMENTS FOR AN GROUP 2 HAZARD OCCUPANCY AS DEFINED BY NFPA13. SYSTEM TO BE ENGAGED BY BUILDING 9-53 MAIN FIRE ALARM PANEL. COORDINATE LOCATION OF FIRE PROTECTION PIPING INTO RF SHIELD ROOM WITH ARCHITECTURAL. ALL SPRINKLER PIPING LOCATED WITHIN TEMPEST ROOM TO BE GROUNDED TO COMMON GROUND BAR LOCATED WITHIN TEMPEST ENCLOSURE. COORDINATE WITH ELECTRICAL. INSTALL GROUNDING AND WALL PENETRATION INTO TWO ICD ROOMS PER ICD ROOM CONSTRUCTION DETAILS PROVIDED BY THE CERTIFIED TEMPEST TECHNICAL AUTHORITY. EFEE\ CE DAWI\GS Tf)k5 Dos REVIEWED FOR CODE COMPLIANCE APPROVED MAY 162010 City of Tukwila BUILDING DIVISION ISSUED FOR CONSTRUCTION MARCH 05, 2018 SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ORIG RELOCATE DOG HOUSE TO BUILDING 9-53 33447-05 FSi AWL 03.05.18 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DRAWN DGK DATE SUBTITLE 01.19.18 CHECKED GLS ENGINEER GLS 01.19.18 01.19.18 TITLE FIRE PROTECTION PLAN RELOCATE DOG HOUSE TO BUILDING 9-53 AWL CHECKED APPROVED 01.19.18 BUILDING 9-53 0 1' 2' 4' 6' SCALE: 3/8" = ii -on RECEIVED CITY OF TUKWILA CURRENT REVISION 33447-05 APR. 2 3 2018 PERMIT CENTER SYMBOL() \ I G DATE 8' FEET 03.05.18 SHEET TWRM261 JOB NO. 03.05.,8 •3D APPROVED MECHANICAL MASTER COL. C—D/5-6 DEV. CENTER, WA DWG NO. COMP NO. 09-053—TWRM261 N SPACE TEMPERATURE SENSORS BY SIEMENS TTE-3 DAIKIN VRF SYSTEM BACnet IP INTERFACE (PROVIDED BY DAIKIN) N BAS NETWORK CONNECTION PROVIDED BY OWNER BAS NETWORK CONNECTION PROVIDED BY OWNER %SIEMENS \\ PXCM-1 BAS CONTROL PANEL BY SIEMENS i 120 VAC BY DIV 26 SEQE\CE OF CPRATIO\ ERV SYSTEM: UNIT START/STOP • THE BMS SHALL START/STOP THE HEAT RECOVERY UNIT. THE BMS SHALL MONITOR PROOF OF RUN STATUS BY A CURRENT SENSOR. • FILTER LOADING • THE BMS SHALL MONITOR THE DIFFERENTIAL PRESSURE SWITCH INITIALLY SET TO 0.4" (SET BY BALANCER), ADJUSTABLE. WHEN PRESSURE SWITCH CLOSES, THE BMS SHALL ISSUE AN ALARM TO THE BUILDING OPERATOR. STARTING SEQUENCE • THE ERV IS PLACED IN OCCUPIED OPERATION VIA THE DDC. THE INTERNAL DAMPER AIR DAMPER WILL BE COMMANDED TO FULLY OPEN. THE DAMPER END SWITCH INDICATE POSITION TO THE MAIN UNIT CONTROLLER INITIALIZING THE FAN STARTING SEQUENCE. THE ECM FAN SEQUENCE WILL BEGIN BY CONTROLLING TO A FIELD ADJUSTABLE CFM SETPOINT. IF AFTER 30 SECONDS THE INDOOR FAN PROVING SWITCH DOES NOT PROVE THE INDOOR FAN ON, THE MAIN UNIT CONTROLLER WILL COMMAND THE INDOOR FAN OFF AND SIGNAL AN ALARM. VRF SYSTEM: GENERAL: • THE VARIABLE REFRIGERANT FLOW (VRF) SYSTEM, INCLUDING THE OUTDOOR HEAT PUMP UNIT, INDOOR FAN COIL UNITS AND REFRIGERANT CONTROLLERS SHALL OPERATE UNDER THE VRF MANUFACTURER'S CONTROL SYSTEM (VRF CONTROL). A SERIAL INTERFACE SHALL BE PROVIDED FOR REMOTE CHANGES THROUGH THE DDC SYSTEM AND TO PROVIDE ALARMS FROM THE VRF CONTROL SYSTEM TO THE DDC SYSTEM. THE VRF CONTROL SYSTEM SHALL OPERATE ALL THERMAL EXPANSION VALVES, COMPRESSORS, ETC. ALL SETPOINTS AND OTHER VALUES SHALL BE ADJUSTABLE THROUGH THE DDC SYSTEM INTERFACE UNLESS INDICATED OTHERWISE. SCHEDULED OPERATION: • THE VRF SYSTEM SHALL BE ENABLED AT ALL TIMES TO MAINTAIN SPACE TEMPERATURE. COORDINATED ALARMS: • THE DDC SHALL MONITOR THE VRF CONTROLLER ALARMS FOR HEAD PRESSURE, REFRIGERANT LEAKAGE AND FAN COIL FILTER LOADING AIR COOLED HEAT PUMP: UNIT START/STOP • THE VRF SYSTEM SHALL START/STOP EACH AIR COOLED HEAT PUMP TO MAINTAIN SPACE TEMPERATURE. PROOF OF RUN STATUS SHALL BE MONITORED BY THE DDC SYSTEM WITH A CURRENT SENSOR, UNLESS NOTED OTHERWISE. TYPICAL VRF FAN COIL UNIT UNIT START/STOP • THE VRF SYSTEM SHALL START/STOP EACH VRF FAN COIL UNIT TO MAINTAIN SPACE TEMPERATURE. PROOF OF RUN STATUS SHALL BE MONITORED BY THE DDC SYSTEM WITH A CURRENT SENSOR, UNLESS NOTED OTHERWISE. THE DDC SYSTEM SHALL MONITOR THE ROOM TEMPERATURE, AIRFLOW AND OPERATION MODE. TEMPERATURE CONTROL • EACH SPACE TEMPERATURE SENSOR SHALL RESET THE FAN COIL DISCHARGE TEMPERATURE TO MAINTAIN THE SPACE SETPOINT. AS THE CALL FOR COOLING/HEATING INCREASES, THE VRF CONTROL SYSTEM SHALL OPEN THE FAN COIL UNIT'S REFRIGERANT CONTROL VALVE. AS THE CALL FOR COOLING OR HEATING DROPS, THE VRF CONTROL SYSTEM SHALL CLOSE THE FAN COIL UNIT'S REFRIGERANT CONTROL VALVE AT ALL TIMES. • SPACE TEMPERATURE SETPOINT SHALL BE 70T ± 5F (ADJUSTABLE) PROFESSIONAL STAMP & SIGNATURE APPLIES TO WORK WITHIN THE CLOUDED REVISION AREAS ONLY AS INDICATED • FSi consulting engineers Seattle, Washington Solutions 8c Service CC \S-RUCTIO\ OTES THE HVAC. COMMUNICATION WIRING PENETRATING THE ICD ROOM SHALL BE FILTERED AND INSTALLED PER THE ICD ROOM CONSTRUCTION DETAILS PROVIDED BY THE CERTIFIED TEMPEST TECHNICAL AUTHORITY. COORDINATE WITH ELECTRICAL. ISSUED FOR CONSTRUCTION MARCH 05, 2018 \10 -DOSS rREVIEWED FOR CODE COMPLIANCE APPROVED MAY 16 2313 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA APR 2 3 2018 PERMIT CENTER 11 SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ORIG RELOCATE DOG HOUSE TO BUILDING 9-53 33447-05 FSi AWL 03.05.18 03.05.18 SIGNED ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN DGK CHECKED GLS ENGINEER GLS CHECAWL KED DATE 01.19.18 APPROVED APPROVED 01.19.18 01.19.18 01.19.18 SUBTITLE WIRING DIAGRAM CURRENT REVISION 33447-05 SYMBOL^ I n DATE 03.05.18 TITLE RELOCATE DOG HOUSE TO BUILDING 9-53 MECHANICAL MASTER BUILDING 9-53 COL. C—D/5-6 DEV. CENTER, WA SHEET TWRM310 JOB NO. COMP NO. DWG NO. 09-053—TWRM310 PIPE SLEEVE DETAIL CONDUIT NIPPLE CUT TO LENGTH PIPE PASSING THROUGH GROUND BUSHING RF GASKET SHORT NIPPLE SHIELD PLATE CONDUIT COUPLER INSIDE ICD ROOM STEEL PLATE LOCKNUT WASHER DRYWALL AND PLYWOOD BACKING • SLEEVE DIAMETER TO VARY BASED ON PIPE PASSING THROUGH. • APPLY RF CAULK TO THREADS OF NIPPLES IN COUPLER TO KEEP THEM IN PLACE. • POLISH COUPLER FACE ON A DISK SANDER OR FINE EMERY CLOTH ON GLASS PLATE IF IT IS ROUGH. • RF GASKET TO FILL VOID BETWEEN SHORT NIPPLE AND HOLE IN PLATE. O IF GROUND BUSHING WON'T HOLD COUPLER TIGHT TO SHIELD, USE WASHER AND LOCKNUT. o LOCKNUT AGAINST PLYWOOD TO BE FINGER TIGHT (FOR SLEEVE STABILITY ONLY). ICD 705. HVAC �EF�IGE A\T !I\ ES, STUD (SIDE VIEW) OUTSIDE ICD ROOM 1/2" TO 3/4" PLYWOOD FOR PIPE SLEEVE END SUPPORT • INDIVIDUAL PIPE SLEEVES REQUIRED FOR EACH PIPE/TUBE PENETRATION. • REQUIRED PIPE SLEEVES: o 1/2" FOR 3/8" HVAC TUBE O 3/4" FOR 5/8" HVAC TUBE O 3/4" FOR 1/2" HVAC CONDENSATE DRAIN O 1 1/4" FOR 1" SPRINKLER PIPE • SPACE ADJACENT SLEEVES NO CLOSER THAN 4" ON CENTER. • SLEEVE INSIDE DIAMETER TO BE APPROX. 1/4" LARGER THAN OD OF PENETRATION PIPE/TUBE. • SLEEVE LENGTH MUST BE AT LEAST 6 TIMES ITS INSIDE DIAMETER. • INJECT RF CAULK IN BOTH SIDES OF SLEEVE AROUND PENETRATING TUBE UNTIL COMPLETELY FILLED. CLEAN OFF EXCESS CAULK. • INSIDE ROOM, WRAP 4" FOIL SEAMING TAPE AROUND THE PIPE AND SLEEVE (CENTER OVER SLEEVE MOUTH) OTHER NOTES: • COORDINATE ALL PENETRATIONS WITH ARCHITECT • INSTALL PIPE PENETRATIONS IN DATA FILTER PENETRATION PLATE IN ORDER TO MINIMIZE THE NUMBER OF PLATES. • USE GALVANIZED RMC OR IMC CONDUIT. • USE RF SHIELD FOAM FOR ANY GAPS IN PLYWOOD PENETRATIONS. CO\DE\SATE, A\D SPI SCALE: NONE <LEPIPE PE\ERATIO\ DETAIL rih TWRM61, TWRM111, TWRM261 TWRM500 1/2" GAP BETWEEN EDGE OF DUCT AND FRAMING PROFESSIONAL STAMP & SIGNATURE APPLIES TO WORK WITHIN THE CLOUDED REVISION AREAS ONLY AS INDICATED DUCT INSIDE FRONT VIEW OF WALL DUCT FRAMING INSIDE ICD ROOM FLEX CONNECTION ACOUSTIC LINED Z DUCT 1111111111 !i! INTERIOR WAVEGUIDE FLANGE ILA LAYER (PARTIAL LENGTH SHOWN) U - INTERIOR 5/8 DRYWALL LAYERS RF WAVEGUID SHEET METAL OUTSIDE ICD ROOM ROOM EXTERIOR 5/8 DRYWALL FLEX CONNECTION STUD (SIDE VIEW) AIR DUCT ACOUSTIC FOAM GAP AROUND DUCT DUCT FRAMING • INSTALL BLOCKING IN STUD CAVITY WHERE DUCTS PENETRATE. BLOCK LEAVING APPROX. 1/2" GAP TO DUCT. • INSTALL 1ST INTERIOR DRYWALL LAYER AFTER INSULATING STUD CAVITY. • SCREW 16-18GA SHEET METAL PLATE, WITH A CUTOUT FOR DUCT, TO SHEET METAL TO EXTEND 1.5" PAST BLOCKING TO PROVIDE SCREWING DRYWALL. • PLACE WAVEGUIDE OVER PLATE AND SCREW DOWN WAVEGUIDE TO SHEET METAL PLATE INTERSECTION AND A SEPARATE TAPE LAYER CENTERING OVER WAVEGUIDE TO METAL PLATE INTERFACE. • SPRAY ACOUSTIC FOAM AROUND DUCT PENETRATION FROM OUTSIDE WALL. • ONCE 2ND LAYER OF DRYWALL IS INSTALLED, Z—DUCT AND ISO—COUPLER CAN BE ADDED. ABOVE, BELOW, AND TO THE SIDES COORDINATE WITH ARCHITECTURAL. BLOCKING SURROUNDING THE DUCT. SURFACE FOR 2ND LAYER OF IC] 705 HVAC 1CT PE\ERATIO\ DETAIL 2 SCALE: NONE FSi consulting engineers Seattle, Washington Solutions & Service ISSUED FOR CONSTRUCTION MARCH 05, 2018 TWRM11 TWRM500 poa-voosc REVIEWED FOR CODE COMPLIANCE APPROVED MAY 16 2018 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA APR 2 3 2018 PERMIT CENTER 12 SYM REVISION BY APPROVED. DATE SYM REVISION BY APPROVED DATE ORIG RELOCATE DOG HOUSE TO BUILDING 9-53 33447-05 FSI AWL 03.05.18 D305.,8 nun ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN DGK CHECKED GLS DATE SUBTITLE 01.19.18 01.19.18 EQUIPMENT SCHEDULE CURRENT REVISION SYMBOL 33447-05 0 GDATE 03.05.18 ENGINEER APPROVED BY DEPT. DATE GLS CHECKED AWL APPROVED APPROVED TITLE 01.19.18 01.19.18 RELOCATE DOG HOUSE TO BUILDING 9-53 MECHANICAL MASTER BUILDING 9-53 SHEET TWRM500 JOB NO. COMP NO. COL. DEV. CENTER, WA DWG NO. 09-053—TWRM500