HomeMy WebLinkAboutPermit M18-0064 - BOEING #9-053 - ADDITION & MODIFICATIONSBOEING #9-53
9725 E MARGINAL WAY S
MI 8-0064
Parcel No:
Address:
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-438-9350
Web site: http://www.TukwilaWA.gov
MECHANICAL PERMIT
5624200990 Permit Number: M18-0064
9725 E MARGINAL WAY S BLDG 9-053 Issue Date: 6/5/2018
Permit Expires On: 12/2/2018
Project Name: BOEING #9-053
Owner:
Name:
Address:
Contact Person:
Name:
Address:
Contractor:
Name:
Address:
License No:
Lender:
Name:
Address:
DESIMONE TRUST BOEING
1201 THIRD AVE STE #5010 C/O BNY
MELLON NA, SEATTLE, WA, 98101
MARTIN PROBST
PO BOX 3707; M/C: 46-208 , SEATTLE,
WA, 98124
HOLADAY PARKS INC
4600 S 134 PL, SEATTLE, WA, 98168
HOLADP1379NO
Phone: (206) 852-4985
Phone: (206) 248-9700
Expiration Date: 9/3/2019
DESCRIPTION OF WORK:
ADDITION AND MODIFICATIONS TO THE EXISTING 9-53 BUILDING SYSTEM TO SUPPORT PROCESS LOADS
GENERATED FROM THE SERVER EQUIPMENT. INSTALL A DEDICATED EXHAUST INTERLOCKED TO HYDROGEN
SENSORS ON SECOND FLOOR FOR UPS SYSTEM. FIRST FLOOR NETWORK CLOSET; INSTALL FAN COIL CONNECTED
TO BUILDING CHILLED WATER SYSTEM WITH A SPLIT DX UNIT SERVING AS BACKUP.
Valuation of Work: $822,330.00
Type of Work: REPLACEMENT
Fuel type: ELECT
Fees Collected: $9,004.61
Electrical Service Provided by: SEATTLE CITY LIGHT
Water District: TUKWILA
Sewer District: TUKWILA
Current Codes adopted by the City of Tukwila:
International Building Code Edition:
International Residential Code Edition:
International Mechanical Code Edition:
Uniform Plumbing Code Edition:
International Fuel Gas Code:
2015
2015
2015
2015
2015
National Electrical Code:
WA Cities Electrical Code:
WAC 296-46B:
WA State Energy Code:
2017
2017
2017
2015
Permit Center Authorized Signature:
Date: DCe(05/4�
I hearby certify that I have read and examined this permit and know the same to be true and correct. All
provisions of law and ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this
development permit and agree to the conditions attached to this permit.
Signature: �JJ��
Print Name: i'�'<Af1' Pr -06r
Date: C/S-7 2C/1
This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if
the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: Work shall be installed in accordance with the approved construction documents, and any changes made
during construction that are not in accordance with the approved construction documents shall be
resubmitted for approval.
2: All permits, inspection record card and approved construction documents shall be kept at the site of work
and shall be open to inspection by the Building Inspector until final inspection approval is granted.
3: All construction shall be done in conformance with the Washington State Building Code and the
Washington State Energy Code.
4: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap
the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks,
wells, and other excavations. Final inspection approval will be determined by the building inspector based
on satisfactory completion of this requirement.
5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the
City of Tukwila Building Department (206-431-3670).
6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila
Permit Center.
7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an
approval of, any violation of any of the provisions of the building code or of any other ordinances of the City
of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other
ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction
documents and other data shall not prevent the Building Official from requiring the correction of errors in
the construction documents and other data.
8: ***MECHANICAL PERMIT CONDITIONS***
9: All mechanical work shall be inspected and approved under
Permit Center (206/431-3670).
10: Manufacturers installation instructions shall be available on
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206) 438-9350
1800 MECHANICAL FINAL
0609 PIPE/DUCT INSULATION
0705 REFRIGERATION EQUIP
0701 ROUGH -IN MECHANICAL
0702 SMOKE DETECTOR TEST
a separate permit issued by the City of Tukwila
the job site at the time of inspection.
CITY OF TUKWrLA
Community Development Department
Permit Center
6300 Southcenter Blvd, Suite 100
Tukwila, WA 98188
http://www.TukwilaWA.gov
Mechanical Permit No.
Project No.
Date Application Accepted:
Date Application Expires: l t 4)
(For office use nly)
mik6-tovA
if
MECHANICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**please print**
SITE LOCATION
King Co Assessor's Tax No.: 5624200990
Site Address: 9725 E Marginal Way S, Tukwila, WA. 98108 Suite Number: 9-53 Bldg Floor: 1 & 2
Tenant Name:
The Boeing Company
PROPERTY OWNER
Name: Martin Probst - The Boeing Company
Name: The Boeing Company
City: Seattle State: WA Zip: 98124
Address: PO Box 3707; M/C 46-208
Email: martin.r.probst@boeing.com
City: Seattle State: WA
Zip: 98124
CONTACT PERSON — person receiving all project
communication
Name: Martin Probst - The Boeing Company
Address: PO Box 3707; M/C 46-208
City: Seattle State: WA Zip: 98124
Phone: (206) 852-4985 Fax: (253) 657-4659
Email: martin.r.probst@boeing.com
New Tenant: ❑ Yes ..No
MECHANICAL CONTRACTOR INFORMATION
Company Name: Holaday-Parks Inc
Address: 4600 S 134th PI
City: Tukwila State: WA Zip: 98168
Phone: (206) 248-9700 Fax:
Contr Reg No.: HOLADI*836K2 Exp Date: 05/22/2019
Tukwila Business License No.:
Valuation of project (contractor's bid price): $ 822,330
Describe the scope of work in detail:
Addition and modifications to the existing 9-53 building system to support process loads generated from the server equipment.
Install a dedicated exhaust interlocked to hydrogen sensors on second floor for UPS system. First floor network closet; install fan
coil connected to building chilled water system with a split Dx unit serving as backup. Modify controls to sitewide EMCS system.
Use: Residential: New ❑ Replacement ❑
Commercial: New ❑ Replacement
Fuel Type: Electric VI Gas
Other:
H:Wpplications\Forms-Applications On Line \2016 Applications\Mechanical Permit Application Revised I-4-16.docx
Revised: January 2016
bh
Page 1 of 2
Indicate type of mechanical work being installed and the quantity below:
Unit Type
Qty
Furnace <100k btu
Residential, Nighttime
Furnace >100k btu
1
Floor furnace
55 dB(A)
Suspended/wall/floor
mounted heater
57 dB(A)
Appliance vent
3
Repair or addition to
heat/refrig/cooling
system
1
Air handling unit
65 dB(A)
<10,000 cfm
60 dB(A)
Unit Type
Qty
Air handling unit
Residential, Nighttime
>10,000 cfm
1
Evaporator cooler
55 dB(A)
Ventilation fan
connected to single duct
57 dB(A)
Ventilation system
3
Hood and duct
1
Incinerator — domestic
65 dB(A)
Incinerator—
comm/industrial
60 dB(A)
Unit Type
Qty
Fire damper
Residential, Nighttime
Diffuser
1
Thermostat
55 dB(A)
Wood/gas stove
57 dB(A)
Emergency generator
1
Other mechanical
equipment ((.
1
60 dB(A)
65 dB(A)
Boiler/Compressor
Qty
0-3 hp/100,000 btu
3-15 hp/500,000 btu
15-30 hp/1,000,000 btu
30-50 hp/1,750,000 btu
50+ hp/1,750,000 btu
Noise:
Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is
created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed.
For more details, see TMC 8.22
*Daytim
District of Sound
Producing Source
District of Receiving Property
Residential, Daytime*
Residential, Nighttime
Commercial
Industrial
Residential
55 dB(A)
45 dB(A)
57 dB(A)
60 dB(A)
Commercial
57 dB(A)
47 dB(A)
60 dB(A)
65 dB(A)
Industrial
60 dB(A)
50 dB(A)
65 dB(A)
70 dB(A)
A few sounds are exempt from the noise code, including:
• Warning devices;
Construction and property maintenance during the daytime hours (7am-10pm);
• Testing of backup generators during the day.
PERMIT APPLICATION NOTES -
Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the permit center to comply with current fee schedules.
Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing
and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
1 HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR AUTHORIZED AGENT:
Signature:
Print Name:
Ai.ee;
Martin Probst - The Boeing Company
Mailing Address: PO Box 3707; M/C 46-208
H:\Applications\Forms-Applications On Line \2016 Applications \Mechanical Permit Application Revised 1-4-16. docx
Revised: January 2016
bh
Date: SZZ/ 2-6a
Day Telephone: (206) 852-4985
Seattle WA 98124
City State Zip
Page 2 of 2
Cash"Register Receipt
City of Tukwila
DESCRIPTIONS ACCOUNT
PermitTRAK
QUANTITY ( PAID
$38,230.79
D18-0159 Address: 9725 E MARGINAL WAY S BLDG 9-053 Apn: 5624200990 $9,154.96
Credit Card Fee $266.65
Credit Card Fee
R000.369.908.00.00
0.00
$266.65
DEVELOPMENT $8,627.02
PERMIT FEE
R000.322.100.00.00
0.00
$5,225.77
PLAN CHECK FEE
R000.345.830.00.00
0.00
$3,396.75
WASHINGTON STATE SURCHARGE
6640.237.114
0.00
$4.50
TECHNOLOGY FEE $261.29
TECHNOLOGY FEE
R000.322.900.04.00
0.00
$261.29
EL18-0470 Address: 9725 E MARGINAL WAY S BLDG 9-053 Apn: 5624200990 $19,899.09
Credit Card Fee $579.59
Credit Card Fee
R000.369.908.00.00
0.00
$579.59
ELECTRICAL $18,576.44
PERMIT FEE MULTI-FAM/COMM
R000.322.101.00.00
0.00
$14,861.15
PLAN CHECK FEE
R000.345.832.00.00
0.00
$3,715.29
TECHNOLOGY FEE $743.06
TECHNOLOGY FEE
R000.322.900.04.00
0.00
$743.06
M18-0064 Address: 9725 E MARGINAL WAY S BLDG 9-053 Apn: 5624200990 $9,004.61
Credit Card Fee $262.27
Credit Card Fee
R000.369.908.00.00
0.00
$262.27
MECHANICAL $8,406.10
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
0.00
$33.15
PERMIT FEE
R000.322.100.00.00
0.00
$6,691.73
PLAN CHECK FEE
R000.322.102.00.00
0.00
$1,681.22
TECHNOLOGY FEE $336.24
TECHNOLOGY FEE
R000.322.900.04.00
0.00
$336.24
PG18-0073 Address: 9725 E MARGINAL WAY 5 BLDG 9-053 Apn: 5624200990 $172.13
Credit Card Fee $5.01
Credit Card Fee
R000.369.908.00.00
0.00
$5.01
PLUMBING $160.69
PERMIT FEE
R000.322.100.00.00
0.00
$95.40
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
0.00
$33.15
PLAN CHECK FEE
R000.322.103.00.00
0.00
$32.14
Date Paid: Tuesday, May 22, 2018
Paid By: MARTIN R PROBST
Pay Method: CREDIT CARD 009566
Printed: Tuesday, May 22, 2018 11:50 AM 1 of 2
rifirm
SYSTEMS
DESCRIPTIONS
PermitTRAK
ACCOUNT
QUANTITY
PAID
$38,230.79
PG18-0073 Address: 9725 E MARGINAL WAY S BLDG 9-053 Apn: 5624200990
$172.13
TECHNOLOGY FEE
$6.43
TECHNOLOGY FEE
TOTAL FEES PAID BY RECEIPT: R14545
R000.322.900.04.00
0.00
$6.43
$38,230.79
Date Paid: Tuesday, May 22, 2018
Paid By: MARTIN R PROBST
Pay Method: CREDIT CARD 009566
Printed: Tuesday, May 22, 2018 11:50 AM 2 of 2
eill;APPlirfSYSTEMS
INSPECTION RECORD
Retain a copy with permit
INSPE " i NO.
PIIS cces4
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 5outhcenter BIvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
Project:
goi.)G
9I.4753
Type of Inspection:
p/6-,icAt-- fitok_
Address:
Date Called:
Special Instructions:
,r ,
v
-VS
11
Date Wanted:
i 2 -/3-ice
p. m.
Requester:
Phone No:
206 -707 A39,5"
Approved per applicable codes. Corrections required prior to approval.
COMMENTS: 4t..4414/
�T/`iiQL
//ilee4 r-whge,
Inspettor: / P
Date:
fZD
REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
11/1/2018
City of Tukwila
Department of Community Development
MARTIN PROBST
PO BOX 3707; M/C: 46-208
SEATTLE, WA 98124
RE: Permit No. M18-0064
BOEING #9-053
9725 E MARGINAL WAY S BLDG 9-053
Dear Permit Holder:
Allan Ekberg, Mayor
Jack Pace, Director
In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building
Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric
Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null
and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if
the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180
days. Your permit will expire on 12/2/2018.
Based on the above, you are hereby advised to:
1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each
inspection creates a new 180 day period, provided the inspection shows progress.
-or-
2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire.
Address your extension request to the Building Official and state your reason(s) for the need to extend your permit.
The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your
extension request is granted, you will be notified by mail.
In the event you do not call for an inspection and/or receive an extension prior to 12/2/2018, your permit will become null and void
and any further work on the project will require a new permit and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
Bill Rambo
Permit Technician
File No: M18-0064
6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665
CPERMIT COORD COPY Cj
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: M18-0064
DATE: 05/23/18
PROJECT NAME: THE BOEING COMPANY #9-053
SITE ADDRESS: 9725 E MARGINAL WAY S
X Original Plan Submittal
Response to Correction Letter #
Revision # before Permit Issued
Revision # after Permit Issued
DEPARTMENTS:
uilding ivision
Public Works ❑
A)//)- s'itLf-V
Fire Prevention
Structural
Planning Division
❑ Permit Coordinator
PRELIMINARY REVIEW:
Not Applicable ❑
(no approval/review required)
DATE: 05/24/18
Structural Review Required
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
DUE DATE: 06/21/18
Approved
❑ Approved with Conditions
Corrections Required ❑ Denied ❑
(corrections entered in Reviews) (ie: Zoning Issues)
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg 0 Fire 0 Ping ❑ PW 0 Staff Initials:
12/18/2013
HOLADAY PARKS INC
t.)
Washington State Department of
Labor & Industries
Horne Espanol Contact.
Safety & Health Claims & Insurance
C Page 1 of 3
Search L&I : -1 .t ;,;]
A -'Z. Index tlelp My L&
Workplace Rights Trades & Licensing
HOLADAY PARKS INC
Owner or tradesperson
Principals
BECK, DAVID CARL, PRESIDENT
CONNELL, DANIEL A, PRESIDENT
GIRI, BIJIT, PRESIDENT
PIZZEY, GRACE K, VICE PRESIDENT
FREEL, JERRY LEE, VICE PRESIDENT
PARKS, GERALD T JR, PRESIDENT
(End: 08/12/2015)
NAILON, JUNE ANNETTE, VICE PRESIDENT
(End: 08/12/2015)
O'CONNOR, BONNY K, SECRETARY
(End: 08/12/2015)
BECK, DAVID CLARENCE, TREASURER
(End: 08/12/2015)
VAN DER VEEN, ERIC M, VICE PRESIDENT
(End: 08/14/2013)
PIZZEY, GRACE KATHERINE, VICE
PRESIDENT
(End: 08/14/2013)
VAN DER VEEN, JULIE
ELIZABETH, MEMBER
(End: 08/14/2013)
CONNELL, DANIEL AARON, MEMBER
(End: 08/14/2013)
GIRI, BUIT, MEMBER
(End: 08/14/2013)
KIEL, RINALD HOWARD, MEMBER
(End: 08/14/2013)
WHITMYRE, CHRISTIAN, MEMBER
(End: 08/14/2013)
NELSON, MICHAEL, SECRETARY
(End: 11/04/2010)
PARKS, DAVID L, TREASURER
(End: 11/04/2010)
TALBOT, PAUL, TREASURER
(End: 11/04/2010)
Doing business as
HOLADAY PARKS INC
4600 S 134TH PL
SEATTLE, WA 98168
206-248-9700
KING County
WA UBI No. Business type
578 004 089 Corporation
Help us improve
https://secure.lni.wa.gov/verify/Detail.aspx?UBI=578004089&LIC=HOLADPI379N0&SAW= 6/5/2018
HOLADAY PAR.CS INC
Governing persons
DAVID
BECK
DAN CONNELL;
JERRY FREEL;
BIJIT GIRT;
GRACE PIZZEY;
License
Verify the contractor's active registration / license / certification (depending on trade) and any past violations.
Construction Contractor Active.
Meets current requirements.
License specialties
GENERAL
License no.
HOLADP1379NO
Effective — expiration
01/21/1983— 09/C3/2019
Bond
LIBERTY MUTUA,:_ INS CO
Bond account no.
23000452
Received by L&I
08/23/2002
Insurance
...... ........
Charter Oak Fire ;ns Co
Policy no.
DTCO1 F465357CiF17
$12,000.00
Effective date
09/01/2002
Expiration date
Until Canceled
$1,000,000.00
Received by L&I Effective date
10/31/2017 11/01/2017
Expiration date
11/01/2018
Insurance history
Savings
No savings accounts during the previous 6 year period.
Lawsuits against t.e bond or savings
No lawsuits again; t the bond or savings accounts during the previous 6 year period.
L&I Tax debts
No L&I tax debts a recorded for this contractor license during the previous 6 year period, but some debts
may be recorded : y other agencies.
License Violation,
................................
No license violatic is during the previous 6 year period.
Workers' c ,mp
Do you know if the ausiness has employees? If so, verify the business is up-to-date on workers' comp premiums.
L&I Account ID Account is current.
177,231-00
Doing business as
HOLADAY PARKS INC
Estimated workers reported
Quarter 1 of Year :.318 "Greater than 100 Workers"
L&I account contact
T4 / CASSANDRA SMITH (360)902-5632 - Email: SMCA235@Ini.wa.gov
Public Wo, As Strikes and Debarments
Verify the contract::; is eligible to perform work on public works projects.
Contractor Strike:
No strikes have Len issued against this contractor.
Page 2 of 3