HomeMy WebLinkAboutPermit M18-0065 - ANDOVER MANAGEMENT - UNITS 2, 5 AND 8 RTU REPLACEMENTVACANT/ANDOVER
MANAGEMENT
6450 SOUTHCENTER BLVD
EXPIRED
10/23/19
MI 8-0065
Parcel No:
Address:
City of Tukwila
11
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-438-9350
Web site: http://www.TukwilaWA.gov
MECHANICAL PERMIT
0003200011 Permit Number: M18-0065
6450 SOUTHCENTER BLVD
Project Name: VACANT/ANDOVER MANAGEMENT
Issue Date: 12/31/2018
Permit Expires On: 6/29/2019
Owner:
Name:
Address:
Contact Person:
Name:
Address:
Contractor:
Name:
Address:
License No:
Lender:
Name:
Address:
SOUTHCENTER 6450 BLDG LLC
415 BAKER BL #200 , TUKWILA, WA,
98188
MIKE STRATTON
12646 INTERURBAN AVE S , TUKWILA,
WA, 98168
TCMS OF SEATTLE LLC
PO BOX 11252 , PORTLAND, OR, 97211
TCMSSSL905CB
Phone: (206) 406-8427
Phone: (570) 928-5613
Expiration Date: 2/21/2020
DESCRIPTION OF WORK:
REPLACE RTU UNITS 2, 5 AND 8
Valuation of Work: $0.00
Type of Work:
Fuel type:
Fees Collected: $807.32
Electrical Service Provided by: PUGET SOUND ENERGY
Water District: TUKWILA
Sewer District: TUKWILA
Current Codes adopted by the City of Tukwila:
International Building Code Edition:
International Residential Code Edition:
International Mechanical Code Edition:
Uniform Plumbing Code Edition:
International Fuel Gas Code:
Permit Center Authorized Signature:
2015
2015
2015
2015
2015
National Electrical Code:
WA Cities Electrical Code:
WAC 296-46B:
WA State Energy Code:
2017
2017
2017
2015
Date: (�i S I —�
/
I hearby certify that I have read and examined this permit and know the same to be true and correct. All
provisions of law and ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this
development pet,land agree to the conditions attached to this permit.
Signature
Print Name:
qb2i_ ftqvt1W
Date: C7
This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if
the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: Readily accessible access to roof mounted equipment is required.
2: All construction shall be done in conformance with the Washington State Building Code and the
Washington State Energy Code.
3: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap
the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks,
wells, and other excavations. Final inspection approval will be determined by the building inspector based
on satisfactory completion of this requirement.
4: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the
City of Tukwila Building Department (206-431-3670).
5: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila
Permit Center.
6: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an
approval of, any violation of any of the provisions of the building code or of any other ordinances of the City
of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other
ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction
documents and other data shall not prevent the Building Official from requiring the correction of errors in
the construction documents and other data.
7: ***MECHANICAL PERMIT CONDITIONS***
8: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila
Permit Center (206/431-3670).
9: All permits, inspection record card and approved construction documents shall be kept at the site of work
and shall be open to inspection by the Building Inspector until final inspection approval is granted.
10: Manufacturers installation instructions shall be available on the job site at the time of inspection.
21: TO SCHEDULE ALL FIRE INSPECTIONS CALL 206-575-4407.
11: The attached set of mechanical plans have been reviewed by The Tukwila Fire Marshals Office and are
acceptable with the following concerns:
12: H.V.A.C. units rated at greater than 2,000 cfm require auto -shutdown devices. These devices shall be
separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance
#2437)
13: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings
shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the
power source of the air -moving equipment upon detection of smoke in the main return -air duct served by
such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall
be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1)
14: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2437)
15: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2437)
t \
/" \
16: All new fire alarm systems or modifications to existing systems shall have the written approval of The
Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been
obtained. (City Ordinance #2437) (IFC 901.2)
17: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required
for this project.
18: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances
#2436 and #2437)
19: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply
approval of such condition or violation.
20: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention
Bureau at (206)575-4407.
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206) 438-9350
1400 FIRE FINAL
0703 MECH EQUIP EFF
1800 MECHANICAL FINAL
0705 REFRIGERATION EQUIP
0701 ROUGH -IN MECHANICAL
0702 SMOKE DETECTOR TEST
/ l
CITY OF TUKWILA
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.TukwilaWA.gov
"\
Mechanical Permit No. t\A\ 6(1)- q
Project No. /�
Date Application Accepted: I't/' V
Date Application Expires: it 11/1.17 1
(For office ise only)
MECHANICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**please print**
SITE LOCATION
Site Address: 6450 Southcenter Blvd.
Tenant Name: Vacant/ Andover Management
PROPERTY OWNER
Name: Mike Stratton
Name: Andover Management
City: Tukwila State: WA Zip: 98168
Address: 900 SW 16th St. #100
Email: mstratton@tmlgroup.com
City: Renton State: WA
Zip: 98057
CONTACT PERSON — person receiving all project
conununication
Name: Mike Stratton
Address: 12646 Interurban Ave S
City: Tukwila State: WA Zip: 98168
Phone: (206) 406-8427 Fax:
Email: mstratton@tmlgroup.com
King Co Assessor's Tax No.: 0003200011
Suite Number: 101-107 Floor: 1
New Tenant: ❑ Yes ❑ .. No
MECHANICAL CONTRACTOR INFORMATION
Company Name: TCMS of Seattle
Address: 12646 Interurban Ave S
City: Tukwila State: WA Zip: 98168
Phone: (206) 588-8787 Fax: (206) 588-8998
Contr Reg No.: TCMSSSL905CB Exp Date: 12/31/2018
Tukwila Business License No.: BUS -0996773
Valuation of project (contractor's bid price): $ 43,821
Describe the scope of work in detail:
Replace RTU Units 2, 5 and 8
Use: Residential: New 0 Replacement ❑
Commercial: New ❑ Replacement
Fuel Type: Electric ❑ Gas 0 Other:
H:\Applications\Forms-Applications On Line\2016 Applications\Mechanical Permit Application Revised I-4-16.docx
Revised: January 2016
bh
Page 1 of 2
Indicate type of mechanical work being installed and the quantity below:
Unit Type
Qty
Furnace <100k btu
Residential, Nighttime
Furnace >100k btu
Industrial
Floor furnace
55 dB(A)
Suspended/wall/floor
mounted heater
57 dB(A)
Appliance vent
Commercial
Repair or addition to
heat/refrig/cooling
system
47 dB(A)
Air handling unit
65 dB(A)
<10,000 cfin
3
Unit Type
Qty
Air handling unit
Residential, Nighttime
>10,000 cfin
Industrial
Evaporator cooler
55 dB(A)
Ventilation fan
connected to single duct
57 dB(A)
Ventilation system
Commercial
Hood and duct
47 dB(A)
Incinerator — domestic
65 dB(A)
Incinerator —
comm/industrial
60 dB(A)
Unit Type
Qty
Fire damper
Residential, Nighttime
Diffuser
Industrial
Thermostat
55 dB(A)
Wood/gas stove
57 dB(A)
Emergency generator
Commercial
Other mechanical
equipment
47 dB(A)
60 dB(A)
65 dB(A)
Boiler/Compressor
Qty
0-3 hp/100,000 btu
3-15 hp/500,000 btu
15-30 hp/1,000,000 btu
30-50 hp/1,750,000 btu
50+ hp/1,750,000 btu
Noise:
Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is
created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed.
For more details, see TMC 8.22
District of Sound
Producing Source
District of Receiving Property
Residential, Daytime*
Residential, Nighttime
Commercial
Industrial
Residential
55 dB(A)
45 dB(A)
57 dB(A)
60 dB(A)
Commercial
57 dB(A)
47 dB(A)
60 dB(A)
65 dB(A)
Industrial
60 dB(A)
50 dB(A)
65 dB(A)
70 dB(A)
*Daytime means 7AM-10PM, Monday through Friday and 8AM-10PM, Saturday, Sunday and State -recognized holidays.
A few sounds are exempt from the noise code, including:
• Warning devices;
• Construction and property maintenance during the daytime hours (7am-lOpm);
• Testing of backup generators during the day.
PERMIT APPLICATION NOTES -
Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the permit center to comply with current fee schedules.
Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing
and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR
Signature:
f�
Print Name: Mike Stratton
Date: 05/22/2018
Day Telephone: (206) 406-8427
Mailing Address: 12646 Interurban Ave S Tukwila WA 98168
CityState Zip
H:\Applications\Forms-Applications On Line\2016 Applications\Mechanical Permit Application Revised I-4-I6.docx
Revised: January 2016
bh
Page 2 of 2
r1
y�11LA
Cash Register Receipt
City of Tukwila
Receipt Number
DESCRIPTIONS
PermitTRAK
( ACCOUNT
QUANTITY
PAID
$807.32
M18-0065 Address: 6450 SOUTHCENTER BLVD Apn: 0003200011 $807.32
Credit Card Fee
$23.51
Credit Card Fee
R000.369.908.00.00
0.00
$23.51
MECHANICAL
$753.66
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
0.00
$33.15
PERMIT FEE
R000.322.100.00.00
0.00
$569.78
PLAN CHECK FEE
R000.322.102.00.00
0.00
$150.73
TECHNOLOGY FEE
$30.15
TECHNOLOGY FEE
TOTAL FEES PAID BY RECEIPT: R14552
R000.322.900.04.00 0.00 $30.15
$807.32
Date Paid: Tuesday, May 22, 2018
Paid By: MICHAEL STRATTON
Pay Method: CREDIT CARD 654645
Printed: Tuesday, May 22, 2018 3:35 PM 1 of 1
SYSTEMS
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
Pr 'ect: wNdotief' /�,n
Ty lnspectio �4, pi
A
Date Called:
.X�C�2 '�1,
_
Special Instructions:
Date Wanted:
I/
-�t�j
a.m.
p.m.
Requester:
Phone No:
Approved per applicable codes.
COMMENTS:
irlt4A
Corrections required prior to approval.
/14 (e,PA. wAL
if €%0 * paz_ ct.
fri/fro /
Inspector:
Date:
REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
NorCs
ROOF FRAMING PL/
5CA.L 1/0 • 1'-O
1) CLEV/10,4S £rHONN THU* i ( 3 ' T>s TDP' os "kW,
2.00410m OF PL1(r4O00) . 4‘40VC l'.CrtMNC& 1244111' •
ELEVAPONS 2.+40444N TNU5$ C ) ARC To TOP OF PAPAFET.
3) ALL NAJL$ 54.4.4LL $E k?d COMM 4 (-141;0 .23'4•MN.LlP4GTH}.
4� NAIL. AI_L EC+C>E3 e b• X , INTEP14!D4 TE. FRAMING a 12"7,.�
AKi? 2 R4+4$ a 4"i. 4 e.ot174O1+RY5.. TYP*441. Lr4LC +1 KM ` J
THEN NAIL. ALL 20 440 i a 4 " Y.
4
SEPARATE PERMIT
REQUIRED FOR:
O-Mechanl> 1
PIumbirta
Li�Gas
Pipra
41 ... City of Tukvrila
-Vipy....._. __ .. _ _ S ii,DiNG DIVISION
an review approval is subject to errors and omissions.
pproval of construction documents doss not authorize
t a violation of any adopted code or ordinance. Receipt
cr proved Field y , • h, , ditio actino +iedgst
By:
Date:
cr0'• O'>
x4.4'
10% OW
14%4'
12'-yr4.1V-4 kei
241'-?.
sex samecalz•-
P 444E.L **4era
fie E V.
4.•1.
REVISIONS
s shall be made to the scope
k without prior approval of
wila Building Division.
will faquire a new.plah
clude ad�d,�itional plan review
'•J
Sk i21.0 �'��I4( *�60H.u5
•
4 .16p.F. D(.NS4t 61 (345) Z 1 4 .i60.F. GEH3[ SI C34Ta yl
a B° O'I % ' � e..Oh'
F-4 1-4�
1w-1.1
Vecax PLYN
-4
111.5
•.li wryu�p►. 1 Cv�
•
4,1 ,rig RA •. 0445)
0
2 44H.F'2s:
1w//P7441.1 1414644
Co ENO
2240444144414 •
MCCN WITS
R� APC$4
LOC44T ION
4'.#4 RF'I 043)
2.4434'1
C.)0.q.b
4
:o
-0
REVIEWE. FuI
CODE COMP I ' , .1
APPRO • : •.
JUN 2 0 401re'
it
City of Tu " ' II
BUILDING Di .1 I • N
ityofTula^
BUI
44
RECEIVED
CITY OF TUKWiLA
0
MAY 2 2 2016
PERMIT CENTER
OTT CI 11.1041A
APPROTED
[lb ='1
13'•3'1
SKtHel>
26.54° R.641
2V-104.
al'. a Y2*
DO
i4L% .. le..
MOE= HV01230 t Ar
COMMIT= Eeciaam
41c1 WTI1 art Ur • QIITr
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JUN 2 0 2018
City of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF TUKWILA
MAY 2 2 2018
PERMIT CENTER
Date
04/10/2018
Project Name
Cowlitz Tribe
Project Number
CSL0410201805
Client / Purchaser
TIM - TCMS
FILE IYORK
Submittal Summary Page
RECEIVED
CITY OF TUKWILA
MAY 2 2 2018
PERMIT CENTER
Qty Tag # Model #
Description
1 UNIT # 2 ZE036H10A2C1AAA1A1
STOCKED
1
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JUN 202018
City
BUILDINGTfla
DIVISION
1 RD0410
2PE04703725
UNIT # 5 ZE048H12A2C1AAA1A1
STOCKED
1 RD0410
2PE04703725
3 Ton, York Small Sunline Single Packaged R -410A Air Conditioner,
Single Stage Cooling, 12.0 EER / 14.0 SEER, Single Stage Gas
Aluminum Steel, 100 MBH Input, 208/230-3-60, Direct Drive
• Dry Bulb Economizer and Hood (No Barometric Relief Damper)
with Economizer Fault Detection & Diagnostic (Meets ASHRAE
90.1-2013, IECC 2015, California Title 24, AMCA 511)
• 1/2 HP Direct Drive Blower
• 1" Throwaway Filters
• Simplicity® SE Controller including Discharge Air, Return Air, and
Outdoor Air Temperature Sensors.
• Microchannel All Aluminum Condenser Coil, Copper
tube/Aluminum fin Evaporator Coil
- Galvanized Steel Drain Pan
• Standard Access Doors
Barometric Relief Damper with Hood Kit (Downflow Unit or Duct
Mounted)
Power Exhaust Kit for 208/230-1/230-3-60 Voltage
4 Ton, York Small Sunline Single Packaged R -410A Air Conditioner,
Single Stage Cooling, 12.0 EER / 14.0 SEER, Single Stage Gas
Aluminum Steel, 125 MBH Input, 208/230-3-60, Direct Drive
• Dry Bulb Economizer and Hood (No Barometric Relief Damper)
with Economizer Fauft Detection & Diagnostic (Meets ASHRAE
90.1-2013, IECC 2015, California Title 24, AMCA 511)
• 1 HP Direct Drive Blower
• 1" Throwaway Filters
• Simplicity® SE Controller including Discharge Air, Return Air, and
Outdoor Air Temperature Sensors.
• Microchannel AN Aluminum Condenser Coil, Copper
tube/Aluminum fin Evaporator Coil
• Galvanized Steel Drain Pan
• Standard Access Doors
Barometric Relief Damper with Hood Kit (Downflow Unit or Duct
Mounted)
Power Exhaust Kit for 208/230-1/230-3-60 Voltage
-004149-"
Unitary Unitary Sales Tool v1.5.9.0 Information is subject to change without notice. Check local codes. Printed 04/10/2018
Qty Tag # Model # Description
1 UNIT# 8 ZFO9ON18R2B1AAA1A2 7.5 Ton, Single Packaged R -410A Air Conditioner, Standard
STOCKED Efficiency, Two Stage Cooling, 11.0 EER, 180 MBH Input Aluminized
Steel, Two Stage Gas Heat, 208/230-3-60
• Dry Bulb Low Leak Economizer w/Barometric Relief and Hoods
(Bottom or Horizontal End Return Only) with Economizer Fault
Detection & Diagnostic (Meets ASHRAE 90.1-2013, IECC 2015,
California Title 24, AMCA 511).
• 3 HP High Static Belt Drive Blower
• Standard 2" Throwaway Filters
• Simplicity® SE Controller including Discharge Air, Return Air, and
Outdoor Air Temperature Sensors.
• IntelliSpeed control of the VFD based on stages of cooling
(Provides Single Zone VAV Fan Operation as defined by ASHRAE
90.1 section 6.4.3.10)
• Micro -Channel "all -aluminum" condenser coil, Copper
tube/aluminum fin evaporator coil
• Composite Drain Pan - Front Connection
2PE04704706 Power Exhaust 230V without Baro Relief Downflow or Horizontal
Equipment start-up and commissioning by a factory trained technician is recommended.
Contact your supplying distributor or sales representative for additional information & guidance. :•
Unitary Sales Tool v1.5.9.0
Information is subject to change without notice. Check local codes.
Printed 04/10/2018
YORK
L14
Small Sunline (3-6 Ton
Package) N543
Single Package R -410A Air Conditioner
Page: 4
Project Name: Cowlitz Tribe
Unit Model #: ZE036H10A2C1AAA1A1
Quantity: 1 Tag #: UNIT # 2 STOCKED
System: ZE036H10A2C1AAA1A1
Cooung t'ertormance 1
Total gross capacity 41.2 MBH
Sensible gross capacity 30.3 MBH
Seasonal Efficiency (at ARI) 14.00 SEER
Efficiency (at ARI) 12.00 EER
Ambient DB temp. 83.7 °F
Entering DB temp. 80.0 °F
Entering WB temp. 67.0 °F
Leaving DB temp. 59.0 °F
Leaving WB temp. 57.3 °F
Power input (w/o blower) 2.19 kW
Sound power 81 dB(A)
Refrigerant
Refrigerant type R -410A
Sys1 4 lbs 4 oz
Gas Heating Performance
Entering DB temp. 60 °F
Heating output capacity (Max) 79 MBH
Supply air 1334.2 CFM
Heating input capacity (Max) 100 MBH
Leaving DB temp. 114.8 °F
Air temp. rise 54.8 °F
SSE 80.0 %
Stages 1
Supply Air Blower Performance
Supply air 1334.2 CFM
Ext. static pressure 0.6 IWG
Addl. Unit Losses (Options/Accessories) 0.08 IWG
Blower speed 910 RPM
Duct location Bottom
Motor rating 0.75 HP
Actual required BHP 0.42 HP
Power input 0.39 kW
Elevation 299 ft.
Drive type DIRECT
Speed tap 5
Electrical Data
Power supply 208-3-60
Unit min circuit ampacity 21.3 Amps
Unit max over -current protection 30 Amps
Dimensions & Weight
Hgt 33 in. Len 83 in. Wth 45 in.
Weight with factory installed options 585 lbs.
Clearances
Right 24 in. Front 32 in. Back 36 in.
Tnn 77 in Rntfnni n in 1 oft '3R in
Note: Please refer to the tech guide for listed maximum static pressures
AM® ���\
QUALITY:..y�241111,,
3 Ton
• York Units are Manufactured at an ISO 9001 Registered Facility and Each
Rooftop is Completely Computer -Run Tested Prior to Shipment.
Unit Features
• Single Stage Cooling
• Single Stage Gas Aluminum Steel
• 100 MBH Input
• Unit Cabinet Constructed of Powder Painted Steel, Certified At 1000 Hours
Salt Spray Test (ASTM B-117 Standards)
• Either Supply and/or Return can be Field Converted from Vertical to
Horizontal Configuration without Cutting Panels.
• Full Perimeter Base Rails with Built in Rigging Capabilities
• Scroll Compressor
• Dry Bulb Economizer and Hood (No Barometric Relief Damper) with
Economizer Fault Detection & Diagnostic (Meets ASHRAE 90.1-2013, IECC
2015, California Title 24, AMCA 511)
• 1/2 HP Direct Drive Blower
• Solid Core Liquid Line Filter Driers
• Unit Ships with 1" Throwaway Filters
• Replacement Filters: 2 - (15" x 20" x 1" or 2") and 1 - (14" x 25" x 1" or 2").
Unit accepts 1" or 2" wide filters.
• Single Point Power Connection
• Short Circuit Current: 5kA RMS Symmetrical
• Through -the -Curb and Through -The -Base Utility Connections
• Microchannel All Aluminum Condenser Coil, Copper tube/Aluminum fin
Evaporator Coil
Galvanized Steel Drain Pan
• Standard Access Doors
Standard Unit Controller: Simplicity Control Board
• An Integrated Low -Ambient Control, Anti -Short Cycle Protection, Lead -Lag,
Fan On and Fan off Delays, Low Voltage Protection, On -Board Diagnostic
and Fault Code Display. Allows all units to operate in the cooling mode down
to 0 °F outdoor ambient without additional components or intervention.
• Safety Monitoring - Monitors the High and Low -Pressure Switches, the
Freezestats, the Gas Valve, if Applicable, and the Temperature Limit Switch
on Gas and Electric Heat Units. The Unit Control Board will Alarm on Ignition
Failures, Safety Lockouts and Repeated Limit Switch Trips.
BAS Controller
• Simplicity SE Controller including Discharge Air, Return Air, and Outdoor Air
Temperature Sensors
Warranty
• One (1) Year Limited Warranty on the Complete Unit
• Five (5) Year Warranty - Compressors and Electric Heater Elements
• Ten (10) Year Warranty - Aluminized Heat Exchanger
•
•
Unitary Sales Tool v1.5.9.0
Information is subject to change without notice. Check local codes.
Printed 04/10/2018
..ayoRK Small Sunline (3-6 Ton Package) N543
Page: 6
Single Package R -410A Air Conditioner
Project Name: Cowlitz Tribe Unit Model #: ZE036H10A2CIAAAIAI
Quantity: 1 Tag #: UNIT # 2 STOCKED System: ZE036H10A2CIAAA1A1
ASE UNIT)
D
162 [731
o,00
m
0'-1
204 [93]
167 [761
l0
N
208 [94]
L34 [106]
164 [741
^
^
N
168 [76]
190 [86]
m
m
V1
N
Cr,
CO
^
1-1
LC,
A.
CO
N
mm
1-
.i
.
1-
N
•-•m
_
CO '0
01
.,1 R
.---,
M
JER LOADS (LBS) (B
B I C
M m
V, ^
^
N
.-1 N
CO
^
1,
N
0
0'.1
N
N
N^^
N
N
^
m
^
N.
m
N
O'.
m
^
0
......
N
^
03
N
^
V,
^
.D
^
^
0
.0
0,
^
O
n
Ol
0
LA
.-i
m
^
C
LA
.--1
m
^
v,
N
,-.
M.-'
1 N
N o,
.-1 n.1
N
r'
mN
�V1N
N o,
e1 .N_.
b
e-1
N
u
ttn / co 0 J
a Q
O O
w u.0
W O\
st
u
_
M
sr°u
VI
u
o\
u
O\
u
4
VI
tmA
tmA
V1
M
V1
V,
V,
0
IA
^
IA
m
M ^
1-4
p > J
N M 0 Ov
OA LA V
1--1 -t-
.M_.
mm^,�
d,
4.4:,
^�
�.
J
o
^���
-
J
CD M
N M
CO
cr
m
.--I
ti
N
N
m
ei
N
M
0.o
v, w
a
w
w
m
.O
.o
.O
m
to
_ •--.
S Q
ZQ
\
uN^
^
CO
<
.MMa
~
CO
M
m
CO
N
M
M
M
10
V
N
M
^
M
m
M
V\ .O
•
r
m cn
.-I0'
rl4-I
•
.
.
-
e4
1
.••
.
.•
W0
C
^a, C
M
4 .-
,
0
u
.O O.
M
0 CA
M
8
=
a V
C..
a
M
M
CD
LA
0A
1
IA
p
V
LA
LAA
VVI
1 1.2.1
1--.O T
> w
LA L
m,
m
m
mV
LA
m
�.
m
u
m
J
�, C
�
'1-
r
a V)
0 do
N
CO 00
ni
N VLA
.
00 00
Ln
.--1
VI
.--1
N
N
r....
N
N
N
d
2
CD7- CP
\VI
•
C 0
M ,--,
V,
._, .-1
^
m
M
V
.--,
ut ^
IN
1.1
I�
N
Z la.J
^
a
N
V1
M
co
O,
M
m
m
m
o^,
O^,
00 Ol
m
m
T
m
O,
_____ __
M co
U OPERATING CE
N WEIGHT (LBS), _ LO
T (BASE UNIT) ~ X
u
.A
u
Al
ZEI 632 [287] 1 37.5 [5
ZF 1 468 [212] 33 [8:
Zf 541 [245] , 31.50 [
u
ZF I 640 [290] 37 [9:
u
ZR I 585 [265] , 40 [1
u
re,
MCO
N
.O
CO
.__.
MM
u
u
Mcl
_ _I�
0
,--, en
<
1
u
t1"
v
'0
u
t^i,
590 [268]
610 [277] -1,
u
100
XN I 620 [281]
XP 575 [261]
XP 585 [265]
.mil
Y
•-•hu
M
I m W ,R,W
1-1 . J O 2
cc S
m V
N
N
N
C
N
C 2
N X
2
X
0.
X
87 co
w
K Q Q
r
z
W
2
z
M
a
to
M a
IA
m
M
Cr
.A
M
y
.., M
Cr
\
C r
2
�����//�
N.
0 I- a>
>
C
r
IIIIII�((►�� N Ip
Ih„
m..
°°
z
a• .
2 a•
3 r
...,\.„,,1%Op,„
�'
9
o r
.—mnW
I
aw
a
3
so
CI 01
D. 0.0
1...I
N 11 ‘1)
ma
w tA"
� n -1
- vlm
Nam
I
-
�� �@
N
W ": C
'0 F
,,,
.0'~'
.N-1
LE
,--.
N
1}
cO
�.
v
0
,O ^
W.
.O
.
i
IImo_ymO
-
0'v .-t
J
m
0X
u,-,
m
N
I 314-1
0..,
,--, G
•-1 mm
f
mN0.-1
1
M.~_
1
1
L�
Q
-
N m
1, m m r
IL
._, .yum
tom
0
y.,u
CC1- w N
lllO OH 1 -IE
u a
0' X WZw>Y • 0' 02
Q .-. VJm VI L. o$
S W C 2I-Q10C •11 1--I=
• O0. QC 2Lac 2 Y 0
>m
0'm
2 LA
I- • N
CO 9
2
m w
C • c
111 g am
O ~•_
0. •
N
NCILO
Oou
0
} ,-, 2"-..... W�
0
w� 3N 0 2
r
0-
co 0'a 00
Om VO V�
0' 0 Z v w C
m
o 2 > LD V J
OC 2 v O V
1-1 V2Y3
C C O
V
3 00 ,../ NN
mN O•
C -0'J
r
O
V
,--,
Lel
N1
4-4
M
u
H VW 0 O VI CV Q C 1•1 WW i D W O•'�i AQNNS
Vpp0pJ I
LLI 10= V31-
v
'll
00 -1-000 QMQO 00 VI 0'00'
z 00 0'000 ZC0'WwGC -. . V7 • �:
0 WWl7QV V0 Owr r eC0 NV10' Mw0 VI .y
2Ww Wr 1-It0Q 2 a N NWS M
12-1 Lel J N LLA I- C 0m MI- QIL Jaz -20 '0
CV1 1113,
WW
3
c Oa
•
C.A
�W
LLV n
a
/3.78
[96,0]
.75 [19,1] 19.67
PVC FPT y
C. DRAIN [499,7
LEFT VIEW
SQ C 2 VV V,J= •fww
JvV.V -- I--1 O. W O VI Oa IOW V 2r
8 0201 --102nD Cc_
v Q00 MVIW M 3
OJ
CO 0000'=Om>CQ Q> d
...0".O CI. 1.0 W c0O 21--1 w 1-12 arr Wt;�>ZZ
'0 Cw CO Qr2z0'w wS VIC O 0' K
0mo�am�me�, 000�.1t-11-llxr0a0'0WQo"1xA a ..
2 0.0 w O,.0 CO M O, ei mV JVIW<dO 01••1>�¢ v a Q
OWr W1 --1S N20'H Q20
C >d0 1-vlw Q0' =Vp
QW<C.OV NI10 CV CD= • QV' V1Q,-2 M0 C- 0 ° 0
Vl NNMN M. --IM N. .0 LA YO 20 2 X
Wt7
22V Vf rJw +Q 2J3 2 2J
332 •• CV 20V1 J N 02 HH Vl W O O Q `
pQC OQw•• w»O 0 CD Ww V.0'z O r C w0
ONW VI1-1 O •• -I XC CVCO VIZOJW12y X W r N1-
rrV I- r •• o,V-Iv m0 0Oti1zz r m = $o
toS Sr z co ••r VIQw Lay, ox-, moon)) w 1 V 20"--- `
SD .V. tL O w o_0' 0' Ctn Wr1-1 MVJ
LL 00WM oIrzw 0Vl0' V �V,
--- L m O
V
N0
•n
.myu
'
O10z.+w
ow r -ICJ C 1-200
O N C 1--101-1= D_ 1--1, W 4
32 V con4u Amar GOO ^
H® to ^
�m�
1- r1NM a N .0 ^ CO,
0 ^.00
2 N u
Printed 04/10/2018
Information is subject to change without notice. Check local codes.
LOYORIC
Small Sunline (3-6 Ton
Package) N543
Single Package R -410A Air Conditioner
Page: 7
Project Name: Cowlitz Tribe
Unit Model #: ZE036H10A2C1AAA1A1
Quantity: 1 Tag #: UNIT # 2 STOCKED
System: ZE036H10A2C1AAA1A1
Gas/Electric
Economizer
Hood
HACR
Breaker
Component Location
Component Location
20 Gauge Aluminized
Steel Tubular Heat Exchanger
Power Ventor Motor With
Post Purge Cyde
High Efficiency
Compressor
Knockout
For Side
Power Entry
Slide -In
Economizer
Smoke
Detector
3/4" PVC Female
Condensate Drain
GFCI
Convenience Outlet
Knockout
For Side
Control Entry
Belt Drive Or
Direct Drive
Blower
Simplicity® Lite.
Or Simplicity SE
Control Board
Knockout For Side
Gas Supply Entry
Full Perimeter Baserails
With Forklift Slots And
Lifting Holes
Highly Efficient
Enhanced Copper
Tube/Enhanced
Aluminum Fin
Or
Micro -Channel
Aluminum
Tube/Aluminum
Fin Condenser
Unitary Sales Tool v1.5.9.0
Information is subject to change without notice. Check local codes.
Printed 04/10/2018
691YORIC
Small Sunline (3-6 Ton
Package) N543
Single Package R -410A Air Conditioner
Page: 8
Project Name: Cowlitz Tribe
Unit Model #: ZE036H10A2C1AAA1A1
Quantity: 1 Tag #: UNIT # 2 STOCKED
System: ZE036H10A2C1AAA1A1
L V
) o
Typical Application
ROOF JACK
/ INSTALLATION
I 11117PI
ROOF CURB
Z. INSTALLATION
1 I T I
1 1 1 l I I T
I I 11 I
I T T
l 1l I
1 1 1 1
SLAB ON GROUND
INSTALLATION
f) 0
FIELD -SUPPLIED
DISCONNECT SWITCH
J.
CONDENSATE
ROOF CURB
TRAP
TO
POWER
SUPPLY
CONTROL WIRING
TO INDOOR
THERMOSTAT
RETURN AIR
DUCT
SUPPLY AIR
DUCT
MANUAL
GAS SHUT-OFF
VALVE
TO GAS SUPPLY LINE
Unitary Sales Tool v1.5.9.0
Information is subject to change without notice. Check local codes.
Printed 04/10/2018
ROOF CURB
Z. INSTALLATION
1 I T I
1 1 1 l I I T
I I 11 I
I T T
l 1l I
1 1 1 1
SLAB ON GROUND
INSTALLATION
f) 0
FIELD -SUPPLIED
DISCONNECT SWITCH
J.
CONDENSATE
ROOF CURB
TRAP
TO
POWER
SUPPLY
CONTROL WIRING
TO INDOOR
THERMOSTAT
RETURN AIR
DUCT
SUPPLY AIR
DUCT
MANUAL
GAS SHUT-OFF
VALVE
TO GAS SUPPLY LINE
Unitary Sales Tool v1.5.9.0
Information is subject to change without notice. Check local codes.
Printed 04/10/2018
111YORK
Small Sunline (3-6 Ton
Package) N543
Single Package R -410A Air Conditioner
Page: 10
Project Name: Cowlitz Tribe
Unit Model #: ZE048H12A2C1AAA1A1
Quantity: 1 Tag #: UNIT # 5 STOCKED
System: ZE048H12A2C1AAA1A1
Cooling rerrormance
Total gross capacity 55.0 MBH
Sensible gross capacity 38.6 MBH
Seasonal Efficiency (at ARI) 14.00 SEER
Efficiency (at ARI) 12.00 EER
Ambient DB temp. 83.7 °F
Entering DB temp. 80.0 °F
Entering WB temp. 67.0 °F
Leaving DB temp. 57.6 °F
Leaving WB temp. 56.0 °F
Power input (w/o blower) 2.99 kW
Sound power 80 dB(A)
Refrigerant
Refrigerant type R -410A
Sys1 5 lbs 6 oz
Gas Heating Performance
Entering DB temp. 60 °F
Heating output capacity (Max) 100 MBH
Supply air 1600 CFM
Heating input capacity (Max) 125 MBH
Leaving DB temp. 117.9 °F
Air temp. rise 57.9 °F
SSE 80.0 %
Stages 1
Supply Air Blower Performance
Supply air 1600 CFM
Ext. static pressure 0.83 IWG
Addl. Unit Losses (Options/Accessories) 0.11 IWG
Blower speed 1093 RPM
Duct location Bottom
Motor rating 1.00 HP
Actual required BHP 0.77 HP
Power input 0.72 kW
Elevation 299 ft.
Drive type DIRECT
Speed tap 5
Electrical Data
Power supply 208-3-60
Unit min circuit ampacity 27 Amps
Unit max over -current protection 35 Amps
Dimensions & Weight
Hgt 33 in. Len 83 in. Wth 45 in.
Weight with factory installed options 723 lbs.
Clearances
Right 24 in. Front 32 in. Back 36 in.
Tnn 77 in Rnttnm rl in 1 aft ZR in
Note: Please refer to the tech guide for listed maximum static pressures
CERTIFIED.'
4 Ton
• York Units are Manufactured at an ISO 9001 Registered Facility and Each
Rooftop is Completely Computer -Run Tested Prior to Shipment.
Unit Features
• Single Stage Cooling
• Single Stage Gas Aluminum Steel
125 MBH Input
• Unit Cabinet Constructed of Powder Painted Steel, Certified At 1000 Hours
Salt Spray Test (ASTM B-117 Standards)
• Either Supply and/or Return can be Field Converted from Vertical to
Horizontal Configuration without Cutting Panels.
• Full Perimeter Base Rails with Built in Rigging Capabilities
• Scroll Compressor
• Dry Bulb Economizer and Hood (No Barometric Relief Damper) with
Economizer Fault Detection & Diagnostic (Meets ASHRAE 90.1-2013, IECC
2015, California Title 24, AMCA 511)
• 1 HP Direct Drive Blower
• Solid Core Liquid Line Filter Driers
• Unit Ships with 1" Throwaway Filters
• Replacement Filters: 2 - (15" x 20" x 1" or 2") and 1 - (14" x 25" x 1" or 2").
Unit accepts 1" or 2" wide filters.
• Single Point Power Connection
• Short Circuit Current: 5kA RMS Symmetrical
• Through -the -Curb and Through -The -Base Utility Connections
• Microchannel All Aluminum Condenser Coil, Copper tube/Aluminum fin
Evaporator Coil
Galvanized Steel Drain Pan
• Standard Access Doors
Standard Unit Controller: Simplicity Control Board
• An Integrated Low -Ambient Control, Anti -Short Cycle Protection, Lead -Lag,
Fan On and Fan off Delays, Low Voltage Protection, On -Board Diagnostic
and Fault Code Display. Allows all units to operate in the cooling mode down
to 0 °F outdoor ambient without additional components or intervention.
• Safety Monitoring - Monitors the High and Low -Pressure Switches, the
Freezestats, the Gas Valve, if Applicable, and the Temperature Limit Switch
on Gas and Electric Heat Units. The Unit Control Board will Alarm on Ignition
Failures, Safety Lockouts and Repeated Limit Switch Trips.
BAS Controller
• Simplicity SE Controller including Discharge Air, Return Air, and Outdoor Air
Temperature Sensors
Warranty
• One (1) Year Limited Warranty on the Complete Unit
• Five (5) Year Warranty - Compressors and Electric Heater Elements
• Ten (10) Year Warranty - Aluminized Heat Exchanger
•
Unitary Sales Tool v1.5.9.0
Information is subject to change without notice. Check local codes.
Printed 04/10/2018
gantromr
Small Sunline (3-6 Ton
Package) N543
Single Package R -410A Air Conditioner
Page: 11
Project Name: Cowlitz Tribe Unit Model #: ZE048H12A2C1AAA1A1
Quantity: 1 Tag #: UNIT # 5 STOCKED System: ZE048H12A2C1AAA1A1
Factory Installed Options
ZE048H12A2C1AAA1A1
Product Category:
Nominal Cooling Capacity:
Heat Type and Nominal Heat Capacity:
Blower Option:
Voltage:
Economizer / Damper:
Service Options:
Sensor Options:
Controls:
Refrigeration:
Additional Options:
Cabinet Options:
Product Generation:
• 1 RD0410 - Barometric Relief
Damper with Hood Kit (Downflow
Unit or Duct Mounted) (6.0 lbs)
• 2PE04703725 - Power Exhaust Kit
for 208/230-1/230-3-60 Voltage
(65.0 lbs)
ZE
048
H12
A
2
C
1
A
A
A
1
A
1
York Small Sunline Single Packaged R -410A Air
Conditioner
12.0 EER / 14.0 SEER
4 Ton
Single Stage Cooling
Single Stage Gas Aluminum Steel
125 MBH Input
Direct Drive
1 HP Direct Drive Blower
208/230-3-60
Dry Bulb Economizer and Hood (No Barometric Relief
Damper) with Economizer Fault Detection & Diagnostic
(Meets ASHRAE 90.1-2013, IECC 2015, California Title
24, AMCA 511)
Simplicity® SE Controller including Discharge Air, Retum
Air, and Outdoor Air Temperature Sensors.
Microchannel All Aluminum Condenser Coil, Copper
tube/Aluminum fin Evaporator Coil
1" Throwaway Filters
Galvanized Steel Drain Pan
Standard Access Doors
Field Installed Accessories
Unitary Sales Tool v1.5.9.0 Information is subject to change without notice. Check local codes.
Printed 04/10/2018
layoffic Small Sunline (3-6 Ton Package) N543 Page: 12
Single Package R -410A Air Conditioner
Pro]ect Name: Cowlitz Tribe Unit Model #: ZE048H12A2CIAAAIAI
1
Quantity: 1 Tag #: UNIT # 5 STOCKED System: ZE048H12A2C1AAA1A1
5 (LBS) (BASE UNIT)
117 [531 162 [731
198 [90]
204 [931
N
r
O,
CO
O,
208 [94]
234 [106]
164 1'741
V)
N
N
lD
o
N
0
t0
.O
00
0
ON
m
m
NA
ON
0
00
N
Ql
NO
N
00
l0
00
N
.-i
N
m
N
N
N
CO 00
md;—,-
Q, 00
a
M
m
N
et e1
N
m
N
N
H
m
N
..-1
N
N
IAN
VI
N
N
N
N
m
N
N
N m
m N
N Lo
O,
N 1
r
N
N
00
e4
NI
N
Q
Cn
N
LA
N
VI
m
N
N
N
O,
l0
N
01
N
N
N
O,
.D
Lo
N
m
N
V,
.-i
m
N
Lel
N
mey
h" -:N
.•i
ey A.I
^
co.,
V Nco
a
N `•
00
g
N
u
a.. p •-.
V .2 z
W
M
a
Vmi
m
O,
M
ern
uNi
CO
CO
N
N
.Mil
LA
N
VNi
of
(+l
eD >
NOON N
1-1
J d
VO a
000
m
H
N
0p
00
O,
NI
N
:.N-1
re
�1.�`
.N1
e~-1
.~-1
N
0",
2
IJ
;
-
I-
2
2
2
CD
M
W
m
m
LN
M
,O
00
et m
l0
.ti
.-1
N
m
N
tel
I,y
O
0.
Q
.O
.O
.O
.O
00
,O
.D
0
,0
W
\
_
N
_
N Ol
Q\
ti
CO
CO N
Lo
.D
V,
al
N
m
OQ
CQ
Vl N N Q
0 �'
r0
m
74 eM-I
f;1.1
N
N
ti
e-1
N N
eQn
e-1
M
N
M
N
N
eN+l
H
M
N
M
e•1
r,..:1
000
HO\•
W
m
CO Ol
m
W
rr
__,
N M CO
2
'� u o
.D
a\
r+l
.D
O,
��
M
V
.�
W
0
3
3
N
on
ONm
N
=
I-
1-1
NO
m
to
.-1
N CO
00 m
00
CO
N
00
00
00
2
> >
C W
u
N
u
tLet m/l
u
N
u
Lel
N
u
ml
1/
M
M . /l
N
Vml
N
1m/1
N
V
v.
u
to
N
1m/1
N
u
N
1
2
a�
•^ LC
W
-
—w
v
.m•I
. .�•1
.
r�i
.m-1
ey
er-r
CO.
°°
m
~
d
VI
oCL LA ..i .011
.O00 N
N
y
Ni
0 2
O
^
^
.•�
CO
M
u
W
M
V
u^
N
.-.
m
CO
Q
.0
,0
,0
N
Z Q
N
a
CO
m
O.
.-'1
N
.-1
N
m
000
1
Le,
W _ -
u
VNl
O,
0'l
,m.
O,
m m
m
m
O,
`•
m
0,
m
O,
m
Ol
N
en m.
OPERATING
WEIGHT (LBS)' L(
(BASE UNIT) r X
M •
O,•
M
`�
m
u
en
•
. u
M
O,•
m a
585 [265] 40 [3
CO
m
•01
CO
m
M
1
u
m
u
O
m
u
O
m
o
i I 470 [213]
N
NI
00
.Li,
632 [287]
468 [212]
541 [245]
569 [258]
640 [290]
575 [261]
CO
N
u
m
.Nil
N
N
u
m
,O
O,
N
u
0
.~0
620 [281]
575 [261]
LA
,D
u
Vl
.0i1
CO
N
•—.
mr
.mil
= la
1-y
cc
0
^
r+
CO.
•--• W
m W ,o„,
al p 2
'm = r
V r-1
�' CC
21 -Ir
N
N
N
N
N
N
2
N N
z
N
0C
N
2
X
2
X
2
X
4
X
1
X
Cl.
X
r
¢ VI J Q
—'
W
Z L.0QO Z
ND
z
�•`
N
0
W Q 0 r
^
m a
ut
M
R
vl
b M
C
..,
M
a
..,
m
a
u,
���������\
���IIIIItra
' �-
or
al
=
r
11)
m a d ¢
_
H e
.3...."--1
Iw. ..0.,0140.4114„ li
�'
v ,D r z
• e4 O r
m.� m^ z u
VI
cW
W
v
L.
000 01
■
0_
uQ
d •MO•
ry
•
LI
^ w vim
^
`_" ..m,
_
'Cr `O .1
1,1 .G.
=
.13_
..1 .Nil f
f : �•1"I
•I
rvl
LO
{
__
N
c
v
l
315,2]
X
mN
,--. ,O to .
�� �� ON i
n
N m }
NM I_.
Can
Wn
ON./Ii
ma
ren "'1 tim
.'
V\ m I
N
• d
,Om
y., CD
> vt
O O.r-1 H
I- .~1. w2Lo>>-v r Eg
V£V D. CO
2 0Cw 2 r Q 0 00C .-1 1-1 x
o
_ _ D. et CC OWO O
vl
Y W
ggm
I --N
m�
2
CC
3 m ,D
CC m
o u
N
Nps
• m
mu
r 2 F Z
I- O
Np
W O�
5m 0- O-
r0O L.Ia z�
I- m W nn
m 9 0 W z>
2 LI Zo O•
0C 0 O Y
3 00 CO N
o _
2
O
V
V
v
NN."u
.j
u..
r.
N
• �
1r-1 NU NUw CC UJ mwM LULL WO,. la m 0NQ
,,,._,-1V gz INI NI 1-N gNW u000 00S J VfggW Y'
00� O0N 2V'^">- S m2J u
a
I�
� "_
J ZZ'- -.221-1 a 1-IQn D.- of VI HOr N
2 OO�r 00¢ O0Cr W Ws -. V0 • O,
O WV0et V VO OWrr OCO NVIr HWO to
2WWWor Iti WQ 2Q VI NWS r •"I
1-2-1 VI2 JJ VV=II VI S r Q1Z-. LU QV) W ZH JlV 2 .11 •�
LA
OQ 10 rC 0020 - V Y, ¢S XWw =
cc.,
WVt
mQ
3.78
[96,0]
[19,1]FPT y 19.67
DRAIN [499,7.
LEFT VIEW
•
J3 V10 J 31--1 O.nOQ NW V Sr1
Q O2t-r n200 Cl
2
V 12-1 V1w . 3
CO pant-ulom>IrQ Q�z a
..,D uD.4. eOm'R 2o -cu. -IX .41- I- NU ND
•CCW 00 Qr22rW Wx LA CL 00 W
D -Om O: ON T O: N �Q N Q170 2m 2 Q Vx r
mm. -1000.-1 CO. -.11 V 1--I rO .°C I- OW p Q H
2 0.0,0 O1.0 m M O. yV JN.�QQO 01-•1>.-¢ G >
Oar 1 --IS VI = Q
NU.,
V o
V
LLQ
i- he Q2p
>1C rVIW .rt I- =up 0C p
1.11 Q VI d'cl..D O N NI U3 NmWd • QV'0VI Q.-V'HO 0- 0 V' p
VI,2 NNMNme-Im N QVI-n Zn 2l:J X
=32 •• `A VZO kr, �Vl C3 212-1 h-113/IW O O xQ \
2 Q W •• »OWw.I-r2 0 0E 1"I W
§NwN1n-1 J�n3C OaC lri�OLLIN OJ WN X w NNI
SI.
rVfJ N •• fQr00 0�£�O V12 Z� r 00 ......
0 r V r r .. O£ V J V W
O= xr 2 2 ••r VI Q.r. VI O£J WOOW 0- .--1
r IN -IO 1//
V 2�
l7 •ND u. 0 W ar r2.1 -CC VIWrr1 MU -I O
CC.12.Iw OOOCZ3p onrzW£rVl V V
OWI-1CJ LL cC rmLL 0S O VI C. S 1-100 W
m O .ci
V
00 Cr, O
�"� r
N
."I� ,
wLI- 3E V KMV VIm £r pOn� nCO
00
4
r. -i Plm a • .n ,0 O • crn --en.4,___,...I
2 ® N u
I
7
Printed 04/10/2018
YORK
Small Sunline (3-6 Ton
Package) N543
Single Package R -410A Air Conditioner
Page: 13
Project Name: Cowlitz Tribe
Unit Model #: ZE048H12A2C1AAA1A1
Quantity: 1 Tag #: UNIT # 5 STOCKED
System: ZE048H12A2C1AAA1A1
Component Location
Component Location
Gas/Electric
Economizer
Hood
Knockout
For Side
Power Entry
20 Gauge Aluminized
Steel Tubular Heat Exchanger
HACR
Breaker
Power Vencor Motor Wth
Post Purge Cycle
High Efficiency
Compressor
Slide -In
Economizer
Smoke
Detector
i
�r�1k
t tl;
3/4" PVC Female
Condensate Drain "� I%•'
GFCI
Convenience Outlet ,k
Knockout � Belt Drive Or
For Side Direct Drive
Control Entry Blower
Simplicity® Ute"
Or Simplicity SE
Control Board
Knockout For Side
Gas Supply Entry
Full Perimeter Baserails
With Forklift Slots Md
Lifting Holes
Highly Efficient
Enhanced Copper
Tube/Enhanced
Aluminum Fin
Or
Micro -Channel
Aluminum
Tube/Aluminum
Fin Condenser
Unitary Sales Tool v1.5.9.0 Information is subject to change without notice. Check local codes.
Printed 04/10/2018
MYORIC
Small Sunline (3-6 Ton
Package) N543
Single Package R -410A Air Conditioner
Page: 14
Project Name: Cowlitz Tribe Unit Model #: ZE048H12A2C1AAA1A1
Quantity: 1 Tag #: UNIT # 5 STOCKED System: ZE048H12A2C1AAA1A1
0
Typical Application
ROOF JACK
INSTALLATION
ROOF CURB
/ INSTALLATION
I I 1
1 1 1 1 1 I 1
1 1 1 1 1
1 I
i I
I 1 I
I 1
i. 414
_-J
BMW MEM MINN MINN INNS =IN
MEMO. gni. INNS NM MIMI OMNI
SLAB ON GROUND
INSTALLATION
FIELD -SUPPLIED
DISCONNECT SWITCH
l
j CONDENSATE
TRAP -Ij':" '� TO GAS SUPPLY LINE
ROOF CURB
MANUAL
GAS SHUT-OFF
VALVE
TO
POWER
SUPPLY
CONTROL WIRING
TO INDOOR
THERMOSTAT
RETURN AIR
DUCT
SUPPLY AIR
DUCT
Unitary Sales Tool v1.5.9.0
Information is subject to change without notice. Check local codes.
Printed 04/10/2018
-
o
ROOF CURB
/ INSTALLATION
I I 1
1 1 1 1 1 I 1
1 1 1 1 1
1 I
i I
I 1 I
I 1
i. 414
_-J
BMW MEM MINN MINN INNS =IN
MEMO. gni. INNS NM MIMI OMNI
SLAB ON GROUND
INSTALLATION
FIELD -SUPPLIED
DISCONNECT SWITCH
l
j CONDENSATE
TRAP -Ij':" '� TO GAS SUPPLY LINE
ROOF CURB
MANUAL
GAS SHUT-OFF
VALVE
TO
POWER
SUPPLY
CONTROL WIRING
TO INDOOR
THERMOSTAT
RETURN AIR
DUCT
SUPPLY AIR
DUCT
Unitary Sales Tool v1.5.9.0
Information is subject to change without notice. Check local codes.
Printed 04/10/2018
ITYORIC Predator (3-12N,525 Ton Package)
York Single Package R -410A Air Conditioner
Page: 16
Project Name: Cowlitz Tribe
Unit Model #: ZFO9ON18R2B1AAA1A2
Quantity: 1 Tag #: UNIT# 8 STOCKED
System: ZFO9ON18R2B1AAA1A2
uooung Perrormance
Total gross capacity 99.7 MBH
Sensible gross capacity 71.3 MBH
Efficiency (at ARI) 11.00 EER
Integrated eff. (at ARI) 13.10 IEER
Ambient DB temp. 83.7 °F
Entering DB temp. 80.0 °F
Entering WB temp. 67.0 °F
Leaving DB temp. 58.0 °F
Leaving WB temp. 56.4 °F
Power input (w/o blower) 6.11 kW
Sound power 89 dB(A)
Refrigerant
Refrigerant type R -410A
Sys1 4 lbs 10 oz
Sys2 4 lbs 8 oz
Gas Heating Performance
Entering DB temp. 60 °F
Heating output capacity (Max) 144 MBH
Supply air 3000 CFM
Heating input capacity (Max) 180 MBH
Leaving DB temp. 104.4 °F
Air temp. rise 44.4 °F
SSE 80.0 %
Stages 2
Supply Air Blower Performance
Supply air 3000 CFM
Ext. static pressure 0.6 IWG
Addl. Unit Losses (Options/Accessories) 0.2 IWG
Blower speed 1245 RPM
Max BHP of Motor (including service factor) 3.45 HP
Duct location Bottom
Motor rating 3.00 HP
Actual required BHP 2.03 HP
Power input 1.89 kW
Elevation 299 ft.
Drive type BELT
Electrical Data
Power supply 208-3-60
Unit min circuit ampacity 50.4 Amps
Unit max over -current protection 60 Amps
Dimensions & Weight
Hgt 42 in. Len 89 in. Wth 59 in.
Weight with factory installed options 1055 lbs.
Clearances
Right 12 in. Front 36 in. Back 36 in.
Tnn 79 in Rnffnm rl in 1 gaff ZR in
•
Note: Please refer to the tech guide for listed maximum static pressures
ram J
v.11 CERTIFIEDw=;
7.5 Ton
• York Predator units are manufactured at an ISO 9001 registered facility and
each rooftop is completely computer -run tested prior to shipment.
Unit Features
• Two Stage Cooling
• 180 MBH Input Aluminized Steel, Two Stage Gas Heat
• Full perimeter base rails with built in rigging capabilities
• Unit Cabinet Constructed of Powder Painted Steel, Certified At 1000 Hours
Salt Spray Test (ASTM B-117 Standards)
• Scroll Compressor
• Dry Bulb Low Leak Economizer w/Barometric Relief and Hoods (Bottom or
Horizontal End Return Only) with Economizer Fault Detection & Diagnostic
(Meets ASHRAE 90.1-2013, IECC 2015, California Title 24, AMCA 511).
• 3 HP High Static Belt Drive Blower
• Unit Ships with 2" Throwaway Filters
• Solid Core Liquid Line Filter Driers
• Replacement Filters: 4 - (24" x 16•). Unit accepts 2" or 4" wide filters.
• Short Circuit Current: 5kA RMS Symmetrical
• Through -the -Curb and Through -the -Base Utility Connections
• Single Point Power Connection
• Micro -Channel "all -aluminum" condenser coil, Copper tube/aluminum fin
evaporator coil
• Composite Drain Pan - Front Connection
• Tool -free maintenance with features like hinged doors for all -access panels,
slide -out blower and blower motor tray
BAS Controller
• IntelliSpeed control of the VFD based on stages of cooling. Provides Single
Zone VAV Fan Operation as defined by ASHRAE 90.1 section 6.4.3.10.
• Simplicity SE Controller including Discharge Air, Return Air, and Outdoor Air
Temperature Sensors
Standard Unit Controller: Simplicity Control Board
• Safety Monitoring - Monitors the High and Low -Pressure Switches, the
Freezestats, the Gas Valve, if Applcable, and the Temperature Limit Switch
on Gas and Electric Heat Units. The Unit Control Board will Alarm on Ignition
Failures, Safety Lockouts and Repeated Limit Switch Trips.
• An Integrated Low -Ambient Control, Anti -Short Cycle Protection, Lead -Lag,
Fan On and Fan off Delays, Low Voltage Protection, On -Board Diagnostic
and Fault Code Display. Allows all units to operate in the cooling mode down
to 0 °F outdoor ambient without additional components or intervention.
Warranty
• One (1) Year Limited Warranty on the Complete Unit
• Five (5) Year Warranty - Compressors and Electric Heater Elements
• Ten (10) Year Limited Warranty - Aluminized Steel Heat Exchanger
Unitary Sales Tool v1.5.9.0
Information is subject to change without notice. Check local codes.
Printed 04/10/2018
iYORI(
Predator (3-12.5 Ton Package) N524 Page: 18
York Single Package R -410A Air Conditioner
Project Name: Cowlitz Tribe Unit Model #: ZF090N18R2BIAAAIA2
Quantity: 1 Tag #: UNIT# 8 STOCKED System: ZF09ON18R2B1AAA1A2I
^
15) (BASE UNIT) i
VI., 10
A.. CA m.O
M.�.1 m of M....M m O.M
MMN N NNIn InNNM
N '-1 .-1 .-1 .-1 N N N. .....-1
nN I ryr.ml ry u
... u
I
1
O Al O..O O..... n M n .-1 rn
O. O. LID m M nt0 MM W 0001
N N N M Al N N M M N Al Al
On. �' 0�
,
Nu
^N^�'-'m^M �.O CO A-
O. m O. m M m O`.ti.ti Nrl.i
N ,�_, e-1 .. �.. N N N N
N• w
CO •-1 V
a
11 3
W
170
-I
• --11-
O-
M
J
VmMn m
NIA
VI an 0
al
>
1'i
VIIIIIIIIIIIIIIIIIIIIIIII�II
-�...............
`
o0
A. n COO. GO
E
wr
11
11
4 POINT CORNET
MN ..•d CO.O`CFV.n.O 000.0.
.
'.
I -1x
CC
ail37
11110
V11
D01111
m�
.. M In .0 m n l0 n Oo N CO m
o.rnrnrnno,rnmmo, o, ] a^
SUPPLY
III
II I
I
I II
I
u
Q m V. m NN a. -I V IONnM
mu •
O.
L• .' '---.01 m
O
LII�
1
m o0
N .0.-1 .-1 IO 0 CO DO N.7 cr
._
111111111IIIIIIIIIIIIIIIIIIII
i
LOECATIOOF BASE UN]
38 [965 24[6:
38 [965] 24 [6:
40 [1016 26 [61
38 [965] 24 [6:
40 [1016 24 [6:
40 [1016 26 [61
40 [1016 26 [61
38 [965] 23 [51
38 [965] 23 [51
42.4 [1077 24.76:
42.5 [1080 25.5 [6,
41.6[1057 25.5 [6,
> Z
N o
1 ,viii,,,, 0i0,,,,,,,,
i�IIIIIIIIIIIIII1211111111IIIIIIIIIIIIIIIIIIIIIiiI�
,,,,,,i,�,i,l„i,
1'
v
-
1= r .""'
Al VI Q
Z
^
..O -I .-i
rn
M,�
_ mom__
CD
2
V
r m'�
2 u LO CD
Al-
• -. a
IA.
Fes'
u W
m
_,
,
m
...IL-. W
J
m
>
�Y-.^M M O\O\ V V. CO 00 l0 Cr,
LD VII- m 0. 0...•Q a\ on cc, M..M M
~vuM M M M
i ---s
K S a m m m m n Ln N m co
Q x
2
II -1
m m V
N
'6 Q
>-+
Ce
an
2
1
1 1-
LO m 00 rn n oOOo 03 an ID Al rnrn
a
Al
I
i
21.19
[538]
XHAUST
FLUE
)T SHOWN IP
oa-.1- W w 2 2 Al 0 z m z r r r
NN N N Al N NN N NNN
,,� a1
I (�IIIUI tlp)�jl�l�����
I
II )���« ��
I I,I
1) `I \ �\I1111/
I �IIII`II(I I+ 1101 I
II)�Jp�i'
rd
� ."9
rd
OI
40
rl�
► ���
LA LA VI IA
�'=-"'
I.- , x
1
,iii 1111111RIR
111111 II
Il
1111111
Q.Ori Vt of a VI ^ M V in
'-
w'9 J
0ss
2
,'I
10'J
03•
CD „`
C RI �• � ��Al
'
N2ddJ 7l
m^
mm
m
03 rn
N.m
r32
ma$
LSI
w
V
:�l'
II
'i�ll•
lil
•
f•
QO
Ly
JQ
V
oz m��
W
o
IG�I
TR •
Lai cC
F
CO
vo1
'
Q
y00
cra
• oo
I
r
G
O
RI
,
CD a-.
o
ma
O
mn
Al.-.
/oy
x
I
wan VI
M�
O
M�
C
C
..,-
CC 44-11- oKZ
I
Jd-V
LLEa
0
�0
Nu
I i•• •
Q
J
I`
mn
-.
_
Iff if
d•0 Q
.p; Nu
0.7rncov
•-•...Iu
(Fn<
u
CC
•_.
>J
N
nry,' m
~I,
le
N•J
au 17
F=--12
-1
O r0
V CV
! w •
2md CC 1•••
o� 2i
I -I Fcc
wa> VI ZwT> • r ..m7
>m LLI wWJmm v. or
V 2r 21---acooc .y
KC l -V Yx
H.11
,0 z+
CC LL
`. J
W
•.i •
0g
QO
IV
Vtxn
f.00
r-��~
u
•.Ny-_
r- N,�_,
�m 00
.. L7.,1
N
VQ N
u
�� an a
r0 Al • CD 00 m
e p m In
lrJ OO �' Al•
2 4
O W CN 2 C
V OC Q.. 1-
an
3 N w
O O
O
0- 1Li w 2 3
O O
V d
_- -
ga
20
11r
WOLLI O.
IV-Icc cc a
2
1-- CC w
K3
QO
and.JVI
--
W^ Wu
Vt
oo �00
•
wd Sm
J� ue'
o WC
2r
W w
00
2 V 3
O
? -
O
V
VI W=O OI=n
Z OCI..1,i wW0 �Od0 m O.E..Ic w CC VI 2
QI_Jw `J yz7x Vf�K Q wS m
_ _
J 20-1- QM aCO�> N rvli J
z .n zm I- Lo Wm • .o OC
O Q x OW r 1-.0 x1/11- HQVI-. Q
d�V' Q2 CC IA 17 w2 2 Q >
WNMEMMq
1■I; ,c,
r 2ucC
I Qww
Ca
1-
VV
Q
5.
I
.2-I 2 -s OQWC �V' OGHlJ221V-1-1 �uXiuv2i /-
-1 Q02 z VV- 2 •=CCNW O
mWr a_ cal 0V1 =Q an LI- V OC 2
0m O rF-10 n d1-. Z33w 3
8 r 0 000rw Om•>eQea `"CI. 08 1`"-I O
-• o z..W..x Qrrw r LL AlateLI-
DETAIL A
TIONAL)
I
I
.�
w
>
.-+-,--•gym Owp at-,m=rwwx in cc -.Wu- W
�Om V. N 1n InM . c'W .MOO zOC Z QV1WW M
J W m ...••I N CO rUJ V 1--I r <1- O w 0 21--1 V' an Q>
Z OMO. O. Q•..mO VIOC 01-14, w QS 01--1>a-C2J 21- Q
IJN I -.J W H2 VI2rN QOW Q1-1
11
r
O r
CCOC •>d0 I-Vlw Qr nVOC xZ O V
NQ WN.O.O.neLl, mV1�mJW6 • Q170 ViQ.-l'1 V1 V=
..MMMn E QVI-1O 20217 I -.V W 2
0 V E 0 ,Q 2 M 0
z3 S
l
��
Y
MO
J
-• •CEM 2 M .-a. oo
Q3 mV Z 2 all JN.21-IH OC
5d' Qw •• rNV oC»OWwILrZ O J- r� r oc
25xCL CD UJ^UQ,I.n� ••= IA ..CCC-11-3.=.0QOVw0-1:10 2� GC W LL
0=1-01 1.4 - 1- •• o. vdo 11-/ vWmS QO V1z ZQwwOa G V c
2 21-2K ••1-W CZ0 VIQW Vl =J 2O ApmW M
l0 67w0Qdrnc ...M r zNWr.. HZ
C IH21-4 W OC W 00 c�230 oorzw �r OOJr c• M
o W..00J W oo r m0 m 12o OS O VI. HO 1 -Ix ..d 1J2w
N 3£ r.00rWV m..Vlnmr 00wQ0oO��
Al
- .. NM Cr In .o n m o.CD
Nl
•
1n
r
1-m..
�
p
C0
a2
MY
oZ
,.
I�rrn ,
I an
N
...
0
0
0 N
L
U
U
0
0
a,
0
0 O
0 m
n'
o
0
LWOW' Predator (3-12.5 Ton Package)
N524
York Single Package R -410A Air Conditioner
Page: 19
Project Name: Cowlitz Tribe
Unit Model #: ZFO9ON18R2B1AAA1A2
Quantity: 1 Tag #: UNIT# 8 STOCKED
System: ZFO9ON18R2B1AAA1A2
Low Leak Downflow Economizer
Low Leak Downflow Economizer (shown with optional Power Exhaust)
Fresh Air Hood
(included)
Low Leak Economizer (included)
Power Exhaust (optional)
Barometric
Relief Damper
(included)
Low leak economizers are capable achieving low
leakage rates of 3 cfm/sq. ft at 1" of static pressure,
meeting or exceeding the following standards:
ASHRAE 90.1-2010
ASHRAE 62
AMCA 511 (licensed as Class 1A damper)
International Energy Conservation Code (IECC)
California Title 24
The outdoor intake opening shall be covered with a
rain hood that matches the exterior of the unit. Water
eliminator/filters shall be provided.
Simultaneous economizer/compressor operation is
also possible. Dampers shall fully close on power Toss.
Barometric Relief
Hood (included)
Unitary Sales Tool v1.5.9.0 Information is subject to change without notice. Check local codes.
Printed 04/10/2018
•
RIC Predator (3-12.5 Ton Package)
N524
York Single Package R -410A Air Conditioner
Page: 20
Project Name: Cowlitz Tribe
Unit Model #: ZFO9ON18R2B1AAA1A2
Quantity: 1 Tag #: UNIT# 8 STOCKED
System: ZFO9ON18R2B1AAA1A2
Seismic Certification
725672-UAD-A-0911
(((4) DCL a,m..,.,.,.tA,.,e..,.
SPECIAL SEISMIC CERTIFICATION
OF NON-STRUCTURAL
COMPONENTS AND SYSTEMS
CERTIFICATE OF COMPLIANCE
Johnson �/), �f
Controls
Dynamic Certification Laboratories has qualified the listed packaged rooftop units as CERTIFIED for seismic
applications in accordance with the following codes and standards:
CBC 2010, IBC 2009, ICC -ES AC -156 2010, ASCE 7-05
The following model designations are included in this certification. A complete list of certified models, options,
and installation methods are detailed in report number 90300-1107 by Dynamic Certification Laboratories,
provided by the equipment manufacturer upon request.
Unitary Product Group Packaged Rooftop Units (UPG)
Seismic Qualification Testing was conducted in accordance with and in strict adherence to the standards set
forth within the American Society of Civil Engineers (ASCE 7) by the independent approval agency, Dynamic
Certification Laboratories. The above referenced equipment is APPROVED for seismic applications when
properly installed and used as intended.
The basis of this certification is through testing of the active and energized components per AC156. This
certification covers multiple UPG brands, including York, Johnson Controls, Coleman, Luxaire, Evcon, Fraser -
Johnston and Ready Ship.
The seismic values are obtained from the Maximum Considered Earthquake Short Period Spectral Response
Acceleration, Sds, as determined by the ASCE 7 seismic maps. Various installation locations/isolation
configurations are covered under this certification, limited by the Sds value stated in the following table. A
seismic importance factor, Ip, of 1.5 applies to this certification to include essential facility requirements and life
safety applications for post event functionality. The units are approved for both a 14" rigid and 22" spring isolated,
seismically approved roof curbs, or slab (on grade) mount.
Maximum Design Sds Values of UPG Packaged Rooftop Units
Series
Model
Tons
Sds (g)
Fp/Wp
ZR/ZJ/ZH/ZK/ZW/ZU/JA3*
037
3
2.5
1.88
ZR/ZJ/ZH/ZK/ZW/ZU/JA4*
049
4
2.5
1.88
ZR/ZJ/ZH/ZK/ZW/ZU/JA5*
061
5
2.5
1.88
ZR/ZJ/ZH/ZF/XP/ZK/ZW/ZU/ZS/XA/J06*
078
6.5
2.5
1.88
ZR/ZJ/ZH/ZF/XP/ZK/ZW/ZU/Z5/XA/J07*/T*
090
7.5
2.5
1.88
ZR/ZJ/ZH/ZF/XP/ZK/ZW/ZU/ZS/XA/108*
102
8.5
2.5
1.88
ZR/ZJ/ZH/ZF/XP/ZK/ZW/ZU/ZS/XA/110*/T*
120
10
2.5
1.88
ZR/ZJ/ZH/ZF/XP/ZK/ZW/ZU/ZS/XA/J12*/T*
150
12.5
2.0
1.50
Dynamic Certification Laboratories 1315 Greg Street, Suite 109, Sparks, NV 89431— ph: 775-358-5085
Page 1 of 2
www.shaketest.com
Johnson Controls Unitary Products 1
Unitary Sales Tool v1.5.9.0 Information is subject to change without notice. Check local codes.
Printed 04/10/2018
iallyORK Predator (3-12.5 Ton Package)
N524
York Single Package R -410A Air Conditioner
Page: 21
Project Name: Cowlitz Tribe
Unit Model #: ZFO9ON18R2B1AAA1A2
Quantity: 1 Tag #: UNIT# 8 STOCKED
System: ZFO9ON18R2B1AAA1A2
Seismic Certification
SPECIAL SEISMIC CERTIFICATION
OF NON-STRUCTURAL
COMPONENTS AND SYSTEMS
CERTIFICATE OF COMPLIANCE
Johnson
'� t
Controls
Table of Seismic Des gn Parameters
Site Class
Fa
I,
a,
R,
z/h
D
1.0
1.5
2.5
6.0
1.0
Site and Project Requirements
It is the responsibility of the Design Professional of Record to:
• Provide engineering for the anchorage and restraint of the unit
• Validate Certification Design Parameters with actual site conditions
• Provide engineering of all equipment support structures
• Confirm component configuration
Certification Issued by: Dynamic Certification Laboratories
Document Control Number: 90300-1107-A
Issue Date: 9/2/11
Dr. Ahmad Itani, SE
Dynamic Certification Laboratories
eef
Randy Forristall
Principal Engineer, Commercial Products
YORK Unitary Engineering
Johnson Controls, Incorporated
Page 2 of 2
Dynamic Certification Laboratories 1315 Greg Street, Suite 109, Sparks, NV 89431- ph: 775-358-5085 www.shaketest.com
Unitary Sales Tool v1.5.9.0
Information is subject to change without notice. Check local codes.
Printed 04/10/2018
•
BYO
RIK Predator (3-12.5 Ton Package)
N524
York Single Package R -410A Air Conditioner
Page: 22
Project Name: Cowlitz Tribe
Unit Model #: ZFO9ON18R2B1AAA1A2
Quantity: 1 Tag #: UNIT# 8 STOCKED
System: ZFO9ON18R2B1AAA1A2
Component Location
6 1/2 Through 10 Tons
Simplicity • control board
w/screw connector for T -stat Disconnect location
wiring and network connections (optional disconnect switch)
Terminal block for
hi -voltage connection
Second model
nameplate
inside hinged
access panel
Filter access
(2" or 4" filter options)
Filter drier
(solid core)
Micro -Channel Aluminum
Tube/Aluminum Fin
Condenser
Dual stage
cooling for
maximum
comfort
7
Slide -out motor and
blower assembly for
easy adjustment
and service
Compressor #2
access (high -
efficiency
compressor)
Belt -drive blower motor
VFD location (optional)
Power ventor motor
!i 20 -gauge aluminized
steel tubular heat
exchanger for long life
(stainless steel option)
Two-stage gas
heating to maintain
warm, comfortable
temperature
Intelligent control
board for safe and
efficient operation
4�
Base rails w/forklift
slots (three sides)
and lifting holes
Roof curbs in eight- and
fourteen -inch heights.
Slide -out drain pan
with 3/4" NPT,
female connection
Toolless
door latch
Side entry power
and control wiring
knockouts
Compressor #1 access
(high -efficiency compressor)
Unitary Sales Tool v1.5.9.0
Information is subject to change without notice. Check local codes.
Printed 04/10/2018
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JUP
City
BUILD!
DESCRIPTION
R baV66ELD
CITY O,PH4'N,NKWILA
MAY 2 2 2018
PERMIT CENTER
YORK Sunline 2000 units are convertible single packages with
a common footprint cabinet and common roof curb for all 7-1/2
thru 12-1/2 ton sizes. All units have dual compressors with dual
independent refrigeration circuits. The units were designed for
light commercial applications and can easily be installed on a
roof curb, slab, roof jack or frame.
All units are self-contained and assembled on rigid full
perimeter base rails allowing for 3 -way fork lift access and
overhead rigging. Every unit is completely charged, wired,
piped and tested at the factory to provide for a quick and easy
field installation.
The units are available in the following configurations: cooling
only, cooling with electric heat and cooling with gas heat.
Electric heaters are available as field -installed accessories.
Both down and side discharge airflows are available without
having to swap panels. The installer simply removes the duct
covers for the desired configuration. Economizers may be used
on either side or down discharge applications with no
modifications required.
All models include a 1 -year limited warranty on the complete
unit. Compressors and electric heater elements each carry an
additional 4 -year warranty. Aluminized steel tubular heat
exchangers carry an additional 9 -year warranty.
FEATURES
COMMON FOOTPRINT / COMMON CABINET - All model
sizes and configurations share the exact same footprint cabinet
- and therefore the same roof curb. You now have the flexibility
of setting one curb and, after the internal load has been
determined, placing the proper tonnage unit on that curb. You
can even decide between gas or electric heat after the curb has
been set.
HIGH EFFICIENCY -All units have a minimum EER of 8.5. Gas
/ electric units have electronic spark ignition and power vented
combustion with steady state efficiencies as high as 81.0%.
These efficiencies exceed all legislated minimum levels and
provide low operating costs.
CONVERTIBLE AIRFLOW DESIGN - Both the side and
bottom duct openings are covered when they leave the factory.
If a side supply / side retum is desired you simply remove the
two side duct covers from the outside of the unit and discard
them. If a bottom supply / return is desired you simply remove
the two bottom duct covers and discard them. No panel cutting
MYORIC
530.18-TG2Y (598)
SINGLE PACKAGE
GAS / ELECTRIC UNITS AND
SINGLE PACKAGE AIR CONDITIONERS
D3CE/D3CG102 & D4CE/D4CG090, 120 & 150
7-1/2, 8-1/2, 10 AND 12-1/2 NOMINAL TONS
8.5-9.0 EER
SUNLINE 2000TM
or swapping is required! Convertible airflow design allows
maximum field flexibility and minimum inventory.
FACTORY INSTALLED OPTIONS - Economizers,and
alternate indoor fan motors can be installed at the factory. The
economizers are shipped installed and wired. The outdoor air
hood needs only to be field assembled and installed. Field labor
dollars can be saved by having the components arrive already
installed.
FIELD INSTALLED ACCESSORIES - Accessories were
designed for quick and easy installation. The motorized damper
and economizers simply slide in and electrical connections are
made by modular plugs. Electric heaters mount easily and
knockouts are provided in the internal partitions to connect the
elements to the control box single point kit.
The 14" high roof curb is shipped knocked down. The roof curb
has an insulated deck.
Low ambient controls are available to provide stable unit
operation at outdoor temperatures down to 0°F.
Propane and high altitude kits are also available to cover all
gas heating applications.
MOTORIZED AIR DAMPER - Includes slide-in/plug-in damper
assembly with rainhood and filters. The outdoor air dampers
open when the indoor fan motor is energized. Damper is
capable of providing 0% thru 100% outdoor return air opening.
MANUAL OUTDOOR DAMPER - Provides 0% thru 35% or 0%
thru 100% of return air opening (field adjustable). Designed for
duct mounted side or bottom supply/return applications.
Includes rain hood assembly and filters
WIDE RANGE OF INDOOR AIRFLOWS -All indoor fan motors
are belt -drive type providing maximum flexibility to handle most
airflow requirements. Factory -installed alternate indoor fan
motors are available on some models for high static
applications.
FULL PERIMETER BASE RAILS - The permanently attached
base rails provide a solid foundation for the entire unit and
protect the unit during shipment. The rails provide fork lift
access from 3 sides and rigging holes are also provided so that
an overhead crane can be used to place the units on a roof.
M'- OOloFma
UNIT DIMENSIONS (DCE AND DCG - 7-1/2 THRU 12-1/2 TON)
Flan -SUPPLIED (A) BLOWER
DISCONNECT SWITCH CONTROL WIRING ACCESS
LOCATION ENTRY
33.718
(090.102)
39-L7/8
(120)
47-7/8
(150)
FILTER ACCESS
COMPRESSOR
ACCESS
(Sea Detail MCI
314• PVC FEMALE
COND. DRAIN CONN.
(Sea Detaa M tor Winton) 71
(8) POWER WIRING E my
(See Ptak •Y• for locaaon)
8a1TO14 SUPPLY
AND RETURN AIR_
CPENIN08
(SEE NOTE)
5-1/4
'—ELECTRIC
HEAT
ACCESS
CONDENSER
COIL
3314
ELEC/ELEC
UNITS
(A)
CONTROL WIRING
ENTRY
(B)
POWER WIRING
ENTRY
7-114
FRONT VIEW
UNIT BASE WITH RAIL
Shown separately to Illustrate
7-1/4 . bottom duct openings and
power connection locations.
NOME For curb -mounted units,
refer to the duct hanger dimensions
of the ourb for the proper size of the
supply and return air duct connections.
530.18-TG2Y
All dimensions are in inches. They are
subject to change without notice. Certified
dimensions will be provided upon request.
E> RETURN AIR
��SUPPLY AIR
CONDENSER AIR
r-- -ss, OUTDOOR AIR
I
1 (Economizer)
--ti'
UTILITIES ENTRY DATA
HOLE
OPENING
SIZE
(DIA.)
USED FOR
A
3/4" KO
Control
Wiring
Side
7/8" KO
Bottom*
B
2" KO
Power W ring
(Side or Bottom)*
C
2" KO
Gas Piping (Front)
D
1-11/16" Hole
Gas Piping (Bottom)*
*Openings in the bottom of the unit can be located by the slice
in the insulation.
FIELD -SUPPLIED (A) SLOWER
DISCONNECT SWITCH CONTROL WIRING ACCESS
LOCATION ENTRY
337/8
(080(102)
367/8
(120)
47.7/8
(150)
ALTER ACCESS-
VENT
mEACCESS
CCESS OR
OCE88
,(sae Detail •X•)
34• PVC FEMALE
COND. DRAIN CONN.
(Baa DOM "Y• t location)- 71
(8) POWER WIRING ENTRY
(Sae Ptak "Y 1.r location)
COMM SUPPLY
AND RETURN AR
CPENNOS
(SEE NOTE)
SIM
GAS/ELEC
UNITS
(A)
CONTROL WIRING
ENTRY
(B)
POWER WIRING
ENTRY
GASHEAT
ACCESS
(C)
0418 SUPPLY
ENTRY
VUMT BASE WITH RAIL$
524/2Shown separately to illustrate
CONDENSER
CULL
COMBUSTION
AIR
INLET HOOD
FRONT VIEW
(D)
GAS SUPPLY
ENTRY
Unitary Products Group
bottom duct openings, power and
gee piping connection locating.
NOTE: For ourb-mounted
refer to the duct hanger dimensions
7.1 4 o1 the curb for the proper size of the
supply and return air duct connections.
CLEARANCES
Front
24"
Back
12" (Less Economizer)
36" (With Economizer/
Outdoor Air Damper)
Left Side (Filter Access)
24" (Less Economizer)54"54" (With Economizer)
24"
Right Side (Cond. Coil)
Below Unit1
0" a
Above Unite
72" With 36" Maximum
Horizontal Overhang
(For Condenser Air
Discharge)
1 Units may be installed on combusrble floors made from wood or
class A, B or C roof covering material.
2 Units must be installed oudoors. Overhanging structures or shrubs
should not obstruct condenser air discharge outlet.
3 If economizer is factory installed, the assembled hood kit must be
removed prior to final installation. This hood is 54' long.
NOTE:
DCE Models: Units and ductwork are approved for zero clearance to
combustible materials when equipped with electric heaters.
DCG Models: A 1" clearance must be provided between any combustible
material and the supply air ductwork for a distance of 3 feet from the unit.
The products of combustion must not be allowed to accumulate within a
confined space and recirculate.
Locate unit so that the vent air outlet hood is at least:
• Three (3) feet above any forced air inlet located within 10 horizontal feet
(excluding those integral to the unit).
• Four (4) feet below, 4 horizontal feet from, or 1 foot above any door or
gravity air inlet into the building.
• Four (4) feet from electric meters, gas meters, regulators and relief
equipment.
17
530.18-TG2Y
UNIT DIMENSIONS - Cont'd. -(DCE and DCG - 7-1/2 THRU 12-1/2 TON)
DUCT COVERS - Units are shipped with all air duct
openings covered.
For side duct applications;
1.Remove and discard the supply and return air duct
covers.
2.Connect ductwork to duct flanges on the rear of the
unit.
For bottom duct applications;
1. Remove the side supply and retum air duct covers
to gain access to the bottom supply and retum air
duct covers.
2. Remove and discard the bottom duct covers.
3. Replace the side duct covers.
DETAIL "X"
SIDE SUPPLY AND RETURN AIR DUCT OPENINGS
BAROMETRIC RELIEF RAIN HOOD
li
a--
•
REAR VIEW
23-3/8"
ECONOMIZER RAIN HOOD
27"
3-3/4" A
3/4" CONDENSATE
DRAIN
(MUST BE TRAPPED)
(B) POWER WIRING
ENTRY
DIM
28
ECONOMIZER
31
MOTORIZED DAMPER
31
MANUAL DAMPER 0-100%
24
MANUAL DAMPER 0-35%
••
71"
29-5/8"
7"
3-1/2"
4-1/2"
7A
L.H. END VIEW
DETAIL "Y"
UNIT WITH ECONOMIZER AND FIXED OUTDOOR AIR HOODS
DIM.
A
B
UNIT
7-1/2 TON
8-1/2 TON
10 TON
33-1/4"
32"
32-1/2"
47-1/2"
44-1/2"
46-3/4"
12-1/2 TON
32-1/2"
45"
APPROXIMATE
CENTER OF
BACK GRAVITY
71"
CENTER OF GRAVITY
00.3/4"
CONDENSER
COIL END
FRONT
18 Unitary Products Group
POINT LOADS
_54 -
FRONT
4 POINT LOADS
530.18-TG2Y
6 POINT LOADS
DCE
UNIT
4 - POINT LOADS (LBS)
TOTAL
A
B
C
D
090
1077
238
266
303
270
102
1102
219
277
338
268
120
1177
250
289
342
296
150
1327
271
336
398
322
DCE
UNIT
6 - POINT LOADS (LBS)
TOTAL
A
B
C
D
E
F
090
1077
158
168
178
202
191
180
102
1102
146
166
185
225
202
178
120
1177
167
179
193
228
213
197
150
1327
181
202
224
266
240
214
NOTE: These weights are with economizer and 24kW electric heat.
DCG
UNITA
4 - POINT LOADS (LBS)
TOTAL
A
B
C
9
090
1187
262
298
333
294
102
1202
239
292
369
302
120
1312
279
330
381
322
150
1582
323
383
475
401
DCG
UNIT
6 - POINT LOADS (LBS)
TOTAL
A
B
C
D
E
F
090
1187
175
198
210
222
196
186
102
1202
160
194
220
245
202
181
120
1312
186
220
237
254
215
201
150
1582
215
256
286
317
267
241
NOTE: These weights are with economizer, high heat and oversized motor.
Unitary Products Group
19
530.18-TG2Y
ROOF CURB DIMENSIONS - (DCE and DCG - 7-1/2 THRU 12-1/2 TON)
2" TYP.
24
63-1/4"sNN
y��s
BACK SUPPLY
OF UNIT AIR*
RETURN
DUCT AIR'
SUPPORT RAILS
MIN. ROOF OPENING: DUCT SIZES:
28" Wide X 45" Long Supply Air - 16" X 23-3/4"
Return Ar - 20.1/2" X 23-3/4"
INSULATED DECK
ON OUTDOOR COIL
END OF UNIT
/ 14"
>
FRONT
OF UNIT
93"
`Supply and Return Air (including duct support rails)
as shown, are typical for bottom duct applications.
For location of horizontal duct applications
(on back of unit), refer to Unit Dimension details.
ROOF CURB BENEFITS
FRONT VIEW (JOIST SUPPORTS)
93"
DUCT ---1
SUPPORT RAILS I
H 2"
96"
0 The 4" space between the ducts allows for dumping" an existing roof joist
12:1The 41" overall dimension of the ducts allows ductwork penetration between roof joists that are spaced on 48" centers.
NOTE: Ducts can be installed onto the curb from the roof. All electrical and gas line connections can be made inside the curb.
UNIT AND CURB APPLICATION
3/4" X 1-1/4" WIDE GASKETING FOR CURB
FRAME AND ALL DUCT SUPPORT SURFACES
UNIT BASE
3.69"
BASE RAIL
COUNTERFLASHING
CANT STRIP
INSULATION AND ROOFING MATERIAL
WOOD NAILER -
14"
8" MIN. ABOVE FINISHED ROOF —
CURB FRAME—
INSULATION
ROOF DECK AND SUPPORT STRUCTURE
20 Unitary Products Group
Da z F
DESCRIPTION
530.18 -TG 1 Y (295)
LIYORK®
SINGLE PACKAGE
AIR-COOLED
AIR CONDITIONERS
D3CE 036, 048, 060 & DICE 072
D6CG 036, 048, 060 & DICG 072
3, 4 AND 5 NOMINAL TONS (10 SEER)
AND 6 NOMINAL TO
REVIEWED FOR
CODE COMPLIANCE
JUN 2 0 2018
RECEIVED §UNLINE
s +63m T U K�dV I h
MAY 2 2 2018
PERMIT CENTER
YORK Sunline 2000 units are convertible single package air
conditioners with a common cabinet and a common roof curb
for the 3, 4, 5 and 6 ton sizes. The units were designed for
residential., light commercial and commercial applications.
They can easily be installed on a roof curb, slab, roof jack or
frame.
All units are self-contained and assembled on rigid full
perimeter base rails with fork lift slots on three sides and holes
for overhead rigging. Every unit is completely piped, wired,
charged and tested at the factory to provide for a quick and
easy field installation.
The units are available in cooling only, and cooling with gas
heat. Electric heaters are available as field -installed
accessories.
The cabinet is constructed of galvanized steel, painted with
long lasting, durable, and aesthetically pleasing power paint.
Paint finish meets 750 hour salt spray tests per ASTM -B117
standards.
All models include a 5 -year limited warranty on compressors
and electric heating elements, a 10 -year limited warranty on
gas-fired heat exchangers and a 1 -year limited warranty on all
replacement parts.
FEATURES
COMMON FOOTPRINT/COMMON CABINET - All model
sizes and configurations share a common cabinet and a
common roof curb. The installer has the flexibility of setting one
curb and placing the proper tonnage unit on that curb after the
internal Toad has been determined. He can even decide
between gas or electric heat after the curb has been set.
HIGH EFFICIENCY - All units have a high cooling efficiency,
and gas / electric models have a minimum AFUE of 80%. All
efficiencies exceed legislated minimum levels and provide low
operating costs.
CONVERTIBLE AIRFLOW DESIGN - Both the side and bottom
duct openings are covered when they leave the factory. If a side
supply / side retum is desired, you simply remove the two side
City of Tukwila
DING ' VIS •N
duct covers from the ou�.._•._ �� �• If a
bottom supply / bottom retum is desired, you simply remove
the two knockout panels from the base of the unit and discard
them. No panel cutting or swapping is required! Convertible
airflow design allows maximum field flexibility and minimum
inventory. Economizers may be used on either bottom and side
duct applications with no modifications required.
FACTORY -INSTALLED OPTIONS - Economizers can be
installed at the factory. The economizers are shipped installed
and wired. Only the rain hood needs to be field assembled and
installed. Field labor dollars can be saved by having the
components arrive already installed.
Adjustable belt drive blowers are available on most models
from the factory for complete airflow flexibility.
FIELD -INSTALLED ACCESSORIES - Accessories were
designed for quick and easy installation. The motorized damper
and economizers simply slide in, and electrical connections are
made by modular plugs. Electric heaters mount easily, and
knockouts are provided in the intemal partitions to connect the
elements to the control box single point kit.
The 14" high roof curb is shipped knocked down. An insulated
deck is not required because the bottom of the unit is insulated.
Low ambient controls are available to provide stable unit
operation at outdoor temperatures down to 0°F.
Propane, high altitude and low NOx kits are also available to
cover all gas heating applications.
WIDE RANGE OF INDOOR AIRFLOWS - All 3, 4 and 5 -ton
models operate over a wide range of design conditions with a
3 -speed direct -drive fan motor. The 6 -ton unit has a single speed
direct -drive fan motor. Belt -drive blowers are also available on all
3, 4 and 5 -ton models and on 6 ton, 3-phase models.
FULL PERIMETER BASE RAILS - The permanently attached
base rails provide a solid foundation for the entire unit and
protect the unit during shipment. The rails provide fork lift
access from 3 sides, and rigging holes are also provided so
that an overhead crane can be used to place the units on a roof.
M ‚ OOtotd
-
530.18 -TG 1 Y
FEATURES - CONT'D.
SYSTEM PROTECTION - Crankcase heat and internal
overload protection are standard on all compressors. Every unit
has a liquid line filter -drier, high and low pressure/lose at charge
switches and a suction line freezestat to protect all system
components. All units will provide cooling at ambient
temperatures down to 45°F.
UTILITY CONNECTIONS MADE EASY - Gas and electric
utility knockouts are provided in the unit base as well as the
side of the unit. A clearly identified location is provided to mount
a field supplied electrical disconnect switch. Utility connections
can be made quickly and with a minimum amount of field labor.
SIMPLE CONTROL CIRCUIT - A low voltage printed circuit
board contains a compressor lockout indicator Tight and a low
voltage terminal strip. An additional set of pin connectors is also
provided to simplify the field interface of external controls.
Mate -n -lock plug connectors are used where line and low
voltage wires pass thru internal bulkheads. This allows for
easier troubleshooting and component replacement. The
electrical control box is not located in the compressor
compartment so the access cover can be removed for
troubleshooting without affecting the normal system operating
pressures. All wiring internal to the unit is color/number coded.
AIR FILTERS - Units are shipped with 1" disposable filters. The
unit filter racks can accommodate 1" or 2" filters without any
modifications.
61YORIC SUNLINE 2000T""
LOW VOLTAGE RELAY BOARD 20 GAUGE ALUM NIZED STEEL
AND TERMINAL STRIP TUBULAR HEAT EXCHANGER
ELECTRICAL DISCONNECT
MOUNTING LOCATION
(Field Installed)
ECONOMIZER HOOD
DIRECT DRIVE
BLOWER MOTOR
(Belt Drive Option
also available on
some models)
ELECTRIC HEAT ACCESSORY
LOCATION (Elec/Elec Units)
POWER VENTER MOTOR
OUTDOOR AIR OPENING
FOR SLIDE-IN/PLUG IN
INTERNAL ECONOMIZER
(OPTION/ A CCESSORY)
SIDE RETURN AIR
DUCT OPENING
(Retum Air & Supply Air
Side by Side)
BOTTOM RETURN AIR
DUCT OPENING
(Retum Air & Supply Air
Side by Side)
3/4" PVC FEMALE
CONDENSATE DRAIN
KNOCKOUTS FOR SIDE
POWER AND CONTROL
ENTRY
TERMINAL BLOCK
(For Single Point Power
Supply on Elec/Elec Units)
KNOCKOUT FOR BOTTOM
GAS SUPPLY ENTRY
KNOCKOUT FOR BOTTOM
POWER ENTRY
COPPER TUBE /
ALUMINUM FIN
CONDENSER COIL
HIGH EFFICIENCY
COMPRESSORS
WITH CRANKCASE
HEAT
BASE RAILS
WITH FORKLIFT SLOTS
AND LIFTING HOLES
KNOCKOUT FOR SIDE
GAS SUPPLY ENTRY
MODEL DCG
(Gas Heating)
TABLE OF CONTENTS
Description
Features
Ratings
Physical Data
Component Weights
Cooling Capacities - 3
Cooling Capacities - 4
Cooling Capacities - 5
Cooling Capacities - 6
Blower Performance -
Blower Performance -
Blower Performance -
Ton
Ton
Ton
Ton
3 & 4 Ton w/Belt-Drive
5 & 6 Ton w/Belt-Drive
3 - 6 Ton w/Direct-Drive
1 Option and Accessories
1
3
3
3
4
5
6
7
8
9
10
Static Resistances
Motor and Drive Data
Electrical Data - Basic Units
Elec. Data-Clg./Elec. Htg. 3 & 4 Ton w/Direct-Drive
Elec. Data-Clg./Elec. Htg. 5 & 6 w/Direct-Drive
Elec. Data-Clg./Elec. Htg. 3 & 4 w/Belt-Drive
Elec. Data-Clg./Elec. Htg. 5 & 6 w/Belt-Drive
Field Wiring
Unit Dimensions
Roof Curb Dimensions
Typical Applications
10
11
11
11
12
13
14
15
16
17
19
20
2 Unitary Products Group
530.18 -TG 1 Y
RATINGS
CAPACITY RATINGS - Cooling / Electr
CAPACITY RATINGS - Cooling / Gas Heating
ARI RATINGS/
NOMINAL
COOLING CAPACITY
SOUND
MODEL
ELECTRIC HEAT CAPACITY3
OUTPUT
80 / 67-95°F
RATING2
(KW)
TEMP.
MBH
SEER
EER
(bels)
240V
480V
600V
DCE036
40
10.10
9.30
8.8
5 7, 10,
7, 10,
10,
(bels)
1
17.1
2
16
16.7
(%)
(%)
15&20
15&20
15&20
DCE048
48
10.35
9.45
8.6
5 7, 10,
7, 10,
10,
81.6
75.9
15-45
1/2
DCG036N079
15&20
15&20
15&20
DCE060
59
10.15
9.40
8.8
5, 7, 10,
7, 10, 15
10, 15,
DCG048N060
48
10.35
9.45
8.6
15,20 & 30
20 & 30
20 & 30
DCE072
72
-
9.00
8.4
5, 7, 10,
7, 10, 15,
10, 15,
8.6
125
99
80.3
80.6
15.20 & 30
20 & 30
20 & 30
CAPACITY RATINGS - Cooling / Gas Heating
Ratings
Z
are in accordance wlth ARI Standard 210. Sound ratings are in accordance with ARI Standard 270. 3Heaters are available as accessories - all with single point power supply.
SEER = Seasonal Energy Efficiency Ratio - the total cooling output in BTU's during a normal amcal usage period for cooling divided by the tots electric power input in watt-hours during be same period.
EER = Energy Efficiency Ratio - the cooling capacity in Btu's per hour (Btuh) divided by the power input in watts at any given set of rating conditions, expressed in BTUH per watt (BTUHM.ett).
AFUE = Annual Fuel Utilization Efficiency - determined in accordance with DOE test procedure.
S.S.E. = Steady State Efficiency. (Percent Output).
S.E. = California Seasonal Efficiency - determined in accordance with test procedures as specified by the State of Califomia Energy Commission. Furnaces are available with a low NOx accessory.
= Not ARI Listed.
PHYSICAL DATA -
MODELS
ARI RATINGS1
GAS HEAT CAPACITY
MODEL
COOLING CAPACITY
SOUND
INPUT
OUTPUT
AFUE
S.S.E.
12 x 10
1
1.5
TEMP.
GAS
ROWS DEEP
FINS PER INCH
FACE AREA(Sq. Ft.)
80 / 67-95°F
RATING2
(MBH)
(MBH)
CONDENSER
FAN
PROPELLER DIA. (in.)
FAN MOTOR HP
NOM. CFM TOTAL
S.E.
RISE
LINE SIZE
MBH
SEER
EER
1
16
17.1
(bels)
1
17.1
2
16
16.7
(%)
(%)
(%)
(°F)
(in. OD)
DCG036N040
40
10.10
9.30
8.6
50
40
80.9
81.6
75.9
15-45
1/2
DCG036N079
40
10.10
9.30
8.6
100
79
80.5
80.8
73.6
40-70
1/2
DCG048N060
48
10.35
9.45
8.6
75
59
80.9
81.6
77.3
25-55
1/2
DCG048N099
48
10.35
9.45
8.6
125
99
80.3
80.6
77.9
45-75
1/2
DCGO6ON079
59
10.15
9.40
8.6
100
79
80.5
80.8
73.6
25-55
1/2
DCGO6ON099
59
10.15
9.40
8.6
125
99
80.3
80.6
77.9
35-65
1/2
DCG072N079
72
-
9.00
8.4
100
79
80.5
80.8
73.6
25-55
1/2
DCG072N099
72
-
9.00
8.4
125
99
80.3
80.6
77.9
35-65
1/2
Ratings
Z
are in accordance wlth ARI Standard 210. Sound ratings are in accordance with ARI Standard 270. 3Heaters are available as accessories - all with single point power supply.
SEER = Seasonal Energy Efficiency Ratio - the total cooling output in BTU's during a normal amcal usage period for cooling divided by the tots electric power input in watt-hours during be same period.
EER = Energy Efficiency Ratio - the cooling capacity in Btu's per hour (Btuh) divided by the power input in watts at any given set of rating conditions, expressed in BTUH per watt (BTUHM.ett).
AFUE = Annual Fuel Utilization Efficiency - determined in accordance with DOE test procedure.
S.S.E. = Steady State Efficiency. (Percent Output).
S.E. = California Seasonal Efficiency - determined in accordance with test procedures as specified by the State of Califomia Energy Commission. Furnaces are available with a low NOx accessory.
= Not ARI Listed.
PHYSICAL DATA -
MODELS
DCE/DCG
036
048
060
072
EVAPORATOR
BLOWER
CENTRIFUGAL BLOWER (Dia. x Wd. in.)
FAN MOTOR HP DIRECT DRIVE)
FAN MOTOR HP BELT -DRIVE)
12 x 10
1/2
1
12 x 10
3/4
1.5
12 x 10
1
1.5
12 x 11
1
1.5
EVAPORATOR
COIL
ROWS DEEP
FINS PER INCH
FACE AREA(Sq. Ft.)
3
13
3.6
3
13
4.3
3
13
5.1
4
13
5.1
CONDENSER
FAN
PROPELLER DIA. (in.)
FAN MOTOR HP
NOM. CFM TOTAL
22
1/2
4.500
22
1/2
4.200
22
1/2
4.500
24
1/2
4.500
CONDENSER
COIL
ROWS DEEP
FINS PER INCH
FACE AREA (Sq. Ft.)
1
16
17.1
1
1922
17.1
1
17.1
2
16
16.7
AIR
FILTERS
(SEE NOTE)
QUANTITY PER UNIT14" X 20" X 1")2
QUANTITY PER UNIT (14" X 25" X 1"
TOTAL FACE AREA (sq. ft.)
1
6.3
2
1
6.3
2
1
6.3
2
1
6.3
^ CHARGE
RFFRIGERANT 22 (lbs /oz 1
6/0
6/6
7/4
10/3
Filter racks are adapted for 1" or 2" thick filters.
COMPONENT WEIGHTS
Basic Unit
COMPONENT
DCE (Cooling only)
MODELS DCE & DCG
3 TON
Options
and
Accessories
DCG (Gas / Electric)
Economizer
40 Mbh
545
4 TON
585
5TON
6 TON
610
670
605
60 Mbh
79 Mbh
99 Mbh
670
725
655
680
735
Motorized Outdoor Air Damper
Electric Heat
Nominal KW)
DCE only)
5-7KW
10 - 15 KW
20 - 30 KW
Roof Mounting Curb
Relief / Fixed Air Damper
Belt -Drive Blower
NOTE: Weights are given in pounds.
Unitary Products Group
50
48
18
23
28
92
10
5
3
9/3/2019
City of Tukwila
Department of Community Development
MIKE STRATTON
12646 INTERURBAN AVE S
TUKWILA, WA 98168
RE: Permit No. M18-0065
VACANT/ANDOVER MANAGEMENT
6450 SOUTHCENTER BLVD
Dear Permit Holder:
Allan Ekberg, Mayor
Jack Pace, Director
In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building
Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric
Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null
and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if
the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180
days. Your permit will expire on 10/23/2019.
Based on the above, you are hereby advised to:
1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or fmal inspection. Each
inspection creates a new 180 day period, provided the inspection shows progress.
-or-
2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire.
Address your extension request to the Building Official and state your reason(s) for the need to extend your permit.
The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your
extension request is granted, you will be notified by mail.
In the event you do not call for an inspection and/or receive an extension prior to 10/23/2019, your permit will become null and void
and any further work on the project will require a new permit and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
Bill Rambo
Permit Technician
File No: M18-0065
6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665
'PERMIT COORD COPY C
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: M18-0065 DATE: 05/23/18
PROJECT NAME: VACANT/ANDOVER MANAGEMENT
SITE ADDRESS: 6450 SOUTHCENTER BLVD
X Original Plan Submittal
Response to Correction Letter #
Revision # before Permit Issued
Revision # after Permit Issued
DEPARTMENTS:
Alit/& it- )4 -1
Building Division
Public Works ❑
*-I1 mac. 1$-(g
Fire Prevention
Structural
Planning Division
❑ Permit Coordinator
PRELIMINARY REVIEW:
Not Applicable ❑
(no approval/review required)
DATE: 05/24/18
Structural Review Required
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
Approved
❑ Approved with Conditions
DUE DATE: 06/21/18
Corrections Required ❑ Denied ❑
(corrections entered in Reviews) (ie: Zoning Issues)
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW ❑ Staff Initials:
12/18/2013
TCMS OF SEATTLE LLC
Hurnce Espanol Contact
Safety & Health Claims & Insurance
Washington State Department of
(Labor & Industries
Page 1 of 2
r—
Search L&I
A -Z Index l lelp My 1..&1
Workplace Rights Trades & Licensing
TCMS OF SEATTLE LLC
Owner or tradesperson
Principals
MOORE, WILLIAM J, MANAGER
Doing business as
TCMS OF SEATTLE LLC
WA UBI No.
602 845 504
Parent company
MOORE HOLDING CORP
P 0 BOX 11252
PORTLAND, OR 97211
570-928-5613
Business type
Limited Liability Company
Governing persons
WILLIAM
J
MOORE
THOMAS HERBURGER;
DAVID RYAN;
JANE RYAN;
License
Verify the contractor's active registration / license / certification (depending on trade) and any past violations.
Construction Contractor Active.
....... ......... ........
Meets current requirements.
License specialties
GENERAL
License no.
TCMSSSL905CB
Effective — expiration
02/01/2010— 02/21/2020
Bond
DEVELOPERS SURETY & INDEM CO
Bond account no.
269810C
$12,000.00
Received by L&I Effective date
02/01/2010 01/27/2010
Expiration date
Until Canceled
Insurance
Valley Forge Ins Co $1,000,000.00
Policy no.
6072891732
Received by L&I Effective date
10/05/2018 10/01/2018
Expiration date
10/01/2019
Insurance history
Savings
No savings accounts during the previous 6 year period.
Lawsuits against the bond or savings
Help us improve
https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602845504&LIC=TCMSSSL905CB&SAW= 12/31/2018
TCMS OF SEATTLE LLC
No lawsuits against the bond or savings accou 'luring the previous 6 year period.
/
L&I Tax debts
No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts
may be recorded by other agencies.
License Violations
No license violations during the previous 6 year period.
Workers' comp
Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums.
This company has multiple workers' comp accounts.
Active accounts
L&I Account ID
878,452-01
Doing business as
TCMS OF SEATTLE LLC
Estimated workers reported
Quarter 3 of Year 2018 "21 to 30 Workers"
L&I account contact
T1 / JAN BENTLEY (360)902-4652 - Email: STR0235@Ini.wa.gov
Track this contractor 0
Account is current
Public Works Strikes and Debarments
Verify the contractor is eligible to perform work on public works projects.
Contractor Strikes
No strikes have been issued against this contractor.
Contractors not allowed to bid
No debarments have been issued against this contractor.
Workplace safety and health
No inspections during the previous 6 year period.
Page 2 of 2
&%Washington State Dept. of Labor & Industries Use of this site is subject to the laws of the state of Washin jton.
Help us improve
https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602845504&LIC=TCMSSSL905CB&SAW= 12/31/2018