HomeMy WebLinkAboutPermit M18-0068 - TRAN RESIDENCE - A/C UNITTRAN RESIDENCE
3813 S 132ND PL
MI 8-0068
Parcel No:
Address:
Project Name:
City of Tukwila
r N
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-438-9350
Web site: http://www.TukwilaWA.gov
1422600120
3813 S 132ND PL
TRAN RESIDENCE
MECHANICAL OTC PERMIT
Permit Number:
Issue Date:
Permit Expires On:
M 18-0068
5/29/2018
11/25/2018
Owner:
Name:
Address:
Contact Person:
Name:
Address:
Contractor:
Name:
Address:
License No:
Lender:
Name:
Address:
PHAN ANDREW L+THUY D TRAN
3813 S 132ND PL , TUKWILA, WA,
98168
KATRINA SIMONSON
1819 CENTRAL AVE S - A-27 , KENT,
WA, 98032
GREEN CITY HTG & A/C INC
948 INDUSTRY DR , TUKWILA, WA,
98188
GREENCH866B2
I//
Phone: (206) 227-6616
Phone: (206) 227-6616
Expiration Date: 1/22/2020
DESCRIPTION OF WORK:
INSTALL A/C UNIT
Valuation of Work: $6,016.00
Type of Work: NEW
Fuel type: ELECT
Fees Collected: $234.86
Electrical Service Provided by: SEATTLE CITY LIGHT
Water District: 125
Sewer District: VALLEY VIEW
Current Codes adopted by the City of Tukwila:
International Building Code Edition:
International Residential Code Edition:
International Mechanical Code Edition:
Uniform Plumbing Code Edition:
International Fuel Gas Code:
Permit Center Authorized Signature:
2015
2015
2015
2015
2015
Las
National Electrical Code:
WA Cities Electrical Code:
WAC 296-46B:
WA State Energy Code:
2017
2017
2017
2015
Date: -)-9
I hearby certify that I have read and examined this permit and know the same to be true and correct. All
provisions of law and ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this
developm .er it and agree to the conditions attached to this permit.
Signature: G4/_ Date:
5 ac7
�n7L/3Tf\
Print Name:
This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if
the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: ***MECHANICAL PERMIT CONDITIONS***
2: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila
Permit Center (206/431-3670).
3: All permits, inspection record card and approved construction documents shall be kept at the site of work
and shall be open to inspection by the Building Inspector until final inspection approval is granted.
4: Manufacturers installation instructions shall be available on the job site at the time of inspection.
5: Except for direct -vent appliances that obtain all combustion air directly from the outdoors; fuel -fired
appliances shall not be located in, or obtain combustion air from, any of the following rooms or spaces:
Sleeping rooms, bathrooms, toilet rooms, storage closets, surgical rooms.
6: Equipment and appliances having an ignition source and located in hazardous locations and public garages,
PRIVATE GARAGES, repair garages, automotive motor -fuel dispensing facilities and parking garages shall be
elevated such that the source of ignition is not less than 18 inches above the floor surface on which the
equipment or appliance rests.
7: Type 1 Hoods, the required grease duct leakage test and light test shall be performed by a special
inspection and testing agency in accordance with I.M.C. Chapter 5.
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206) 438-9350
1800 MECHANICAL FINAL
0701 ROUGH -IN MECHANICAL
CITY OF TU%WILff
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.TulcwilaWA.gov
/
Mechanical Permit No. M i V r 0065
Project No.
Date Application Accepted:
Date Application Expires:
(For office use only)
MECHANICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**please print**
SITE LOCATION
n King Co Assessor's Tax No.: I'4 2.2.1 OO t 20
Site Address: 3% 13 S • 132nd PL• Suite Number: Floor:
Tenant Name: T O►rN CbU... her) New Tenant ❑ Yes DZ..No
PROPERTY OWNER
i
Name:
Name: 1r\ km.iTran
City: C/1 �cState: Zip:
Address: 3%13. S , 132
x..
City: i uY,ULI la State:
A Zip:C I% 1 loa
CONTACT PERSON — person receiving all project
communication
i
Name:
Address:
Qin
City: C/1 �cState: Zip:
Phone: Fax:
Email: L
1(t 0 @ Q reeINCI�1` NeohActn YYn1
MECHANICAL CONTRACTOR INFORMATION
Company Name:n/' C1een 1^ t Neco.i,^/��
Address: \( -- ( 0 114`Qvl A v S. A 21
City: 1/
f ~_ ni- State: toA Zipcis2
Phone:0:40.22,E • 6 le It, Fax:
Contr Reg No.:Date: ' _ l$ • 22
TukwilPBUSe -0°146
License tNo.: 9 9
oiler •COM
Valuation of project (contractor's bid price): $ 1_901\x U0
Describe the scope of work in detail:
IxTh k\\Arlo `P�C� LkX S \c
Use: Residential: New ( Replacement ❑
Commercial: New ❑ Replacement
Fuel Type: Electric Gas ❑ Other:
H:\Applications\Forms-Applications On Line \2016 Applications\Mechanical Permit Application Revised 1-416.docx
Revised: January2016
bh
Page 1 of 2
j
Indicate type of mechanical work being installed and the quantity below:
Unit Type
Qty
Furnace <100k btu
Residential, Nighttime
Furnace >100k btu
Industrial
Floor furnace
55 dB(A)
Suspended/wall/floor
mounted heater
57 dB(A)
Appliance vent
Commercial
Repair or addition to
heat/refrig/cooling
system AG
47 dB(A)
Air handling unit
65 dB(A)
<10,000 cfrn
60 dB(A)
Unit Type
Qty
Air handling unit
Residential, Nighttime
>10,000 cfm
Industrial
Evaporator cooler
55 dB(A)
Ventilation fan
connected to single duct
57 dB(A)
Ventilation system
Commercial
Hood and duct
47 dB(A)
Incinerator — domestic
65 dB(A)
Incinerator —
comm/industrial
60 dB(A)
Unit Type
Qty
Fire damper
Residential, Nighttime
Diffuser
Industrial
Thermostat
55 dB(A)
Wood/gas stove
57 dB(A)
Emergency generator
Commercial
Other mechanical
equipment
47 dB(A)
60 dB(A)
65 dB(A)
Boiler/Compressor
Qty
0-3 hp/100,000 btu
3-15 hp/500,000 btu
15-30 hp/1,000,000 btu
30-50 hp/1,750,000 btu
50+ hp/1,750,000 btu
Noise:
Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is
created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed.
For more details, see TMC 8.22
District of Sound
Producing Source
District of Receiving Property
Residential, Daytime*
Residential, Nighttime
Commercial
Industrial
Residential
55 dB(A)
45 dB(A)
57 dB(A)
60 dB(A)
Commercial
57 dB(A)
47 dB(A)
60 dB(A)
65 dB(A)
Industrial
60 dB(A)
50 dB(A)
65 dB(A)
70 dB(A)
*Daytime means 7AM-10PM, Monday through Friday and 8AM-10PM, Saturday, Sunday and State -recognized holidays.
A few sounds are exempt from the noise code, including:
• Warning devices;
• Construction and property maintenance during the daytime hours (lam -1 Opm);
• Testing of backup generators during the day.
PERMIT APPLICATION NOTES -
Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the permit center to comply with current fee schedules.
Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing
and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER
Signatur
AUTHORIZED AGENT=
Print Nam
a-+-r‘ria rncievsc)
Date: 5/Z8/1$
Day Telephone: 21310 • 221 - (o It Up
Mailing Address: 1%1ck c • A- 2i62.,± W A v18032—
H:WpplicationsWorms-Applications On Line \2016 Applications'Mechanical Permit Application Revised 1-4-16.docx
Revised: January 2016
bh
City State Zip
Page 2 of 2
11
f1
J
‘;',,\,,)
2qo
Receipt Number
R14594
DESCRIPTIONS
PermitTRAK
ACCOUNT QUANTITY
PAID
$234.86
M18-0068 Address: 3813 S 132ND PL
Apn: 1422600120
$234.86
MECHANICAL
$223.68
PERMIT FEE
R000.322.100.00.00
0.00
$190.53
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
0.00
$33.15
TECHNOLOGY FEE
$11.18
TECHNOLOGY FEE
TOTAL FEES PAID BY RECEIPT: R14594
R000.322.900.04.00 0.00
$11.18
$234.86
Date Paid: Tuesday, May 29, 2018
Paid By: GREEN CITY HTG & A/C INC
Pay Method: CHECK 6629
Printed: Tuesday, May 29, 2018 11:12 AM 1 of 1
SYSTEMS
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
M%--ocd2K
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
Pro ect:a
—WA -Al K S..,
of Inspection:
11
t
Chnet tee)
Address:
38/3 /3 z rz- .
I F
4' Me.z1vmel i s cA.
Special Instructions:
Date Wanted: a.m.
p.m.
Requester
`Trv4iJ
Phone No:
z.oc-9q -3Z1y
❑ Approved per applicable codes. LJ Corrections required prior to approval.
COMMENTS:
L6 -k _LA) o(1 -td-, -(4p f7A2
1.149,_,(
Inspector/
Date: j _/3,24,1s7
REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
Green City HTG & A/C INC
Horne Espanol Contact
Safety & Health Claims & Insurance
® Washington State Department of
)Labor & Industries
Search L&I
Page 1 of 3
1
.A-Ztndex Help MyL t
Workplace Rights Trades & Licensing
Green City HTG & A/C INC
Owner or tradesperson
Principals
Simonson„ Jeffrey Orvold, PRESIDENT
Simonson, Katrina Marie, SECRETARY
Doing business as
Green City HTG & A/C INC
WA UBI No.
603 363 739
1819 Central Ave S
Suite A27
KENT, WA 98032
206-227-6616
KING County
Business type
Corporation
License
Verify the contractor's active registration / license / certification (depending on trade) and any past violations.
Construction Contractor Active.
...................................................
Meets current requirements.
License specialties
HeatingNent/Air-Conditioning and Refrig
(HVAC/R)
License no.
GREENCH866B2
Effective — expiration
01/22/2014— 01/22/2020
Bond
_...........
Wesco Insurance Co
Bond account no.
46WB079066
$6,000.00
Received by L&I Effective date
08/25/2016 08/19/2016
Expiration date
Until Canceled
Bond history
Insurance
.........................
Arch Specialty Ins Co $1,000,000.00
Policy no.
AGL0043156-01
Received by L&I Effective date
11/09/2017 11/18/2017
Expiration date
11/18/2018
Insurance history
Savings
No savings accounts during the previous 6 year period.
Lawsuits against the bond or savings
Help us improve
https://secure.lni.wa.gov/verify/Detail.aspx?UBI=603363739&LIC=GREENCH866B2&SAW= 5/29/2018
Green City HTG & A/C INC
Cause no.
16-2-02889-6
Complaint filed by
NADA & JAMES DOHERTY
/
Dismissed
................
Complaint against bond(s) or savings
100180935
Complaint date Complaint amount
02/10/2016 $0.00
L&I Tax debts
No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts
may be recorded by other agencies.
License Violations
Infraction no.
NBERU01619
Issue date
10/24/2017
Violation city
TUKWILA
Type of violation
CONSTRUCTION INFRACTION
Description
Failure to provide consumer with the required
disclosure statement signed and dated by the
customer.
Infraction no.
EJOJP00385
Issue date
08/26/2015
Violation city
BONNEY LAKE
Type of violation
ELECTRICAL CITATION
Description
Class B eligible work - Failure of the person
identified as the installer on the Class B label
to post a Class B label, or number if allowed.
(See WAC 296-46B-908.) 15448 SE 167 PL,
RENTON
Infraction no.
EJOJP00387
Issue date
08/26/2015
Violation city
BONNEY LAKE
Type of violation
ELECTRICAL CITATION
Description
Employing an individual for the purposes of
chapter 19.28 RCW who does not possess a
valid certificate of competency or training
certificate to do electrical work.
Infraction no.
EJOJP00386
Issue date
08/26/2015
Violation city
BONNEY LAKE
Type of violation
ELECTRICAL CITATION
Description
Offering, bidding, advertising, or performing
electrical installations, alterations or
maintenance outside the scope of the firm's
specialty electrical contractors license.
Satisfied
.............
RCWNVAC
18.27.114(1) RCW
Violation amount
$500.00
Satisfied
....................
RCW/WAC
19.28.101 RCW
Violation amount
$100.00
Satisfied
.................
RC W/WAC
19.28.271 RCW
Violation amount
$250.00
Satisfied
RCW/WAC
19.28.041 RCW
Violation amount
$500.00
Page 2 of 3
Help us improve
https://secure.lni.wa.gov/verify/Detail.aspx?UBI=603363739&LIC=GREENCH866B2&SAW= 5/29/2018
Green City HTG & A/C INC
Infraction no.
EJOJP00388
Issue date
08/26/2015
Violation city
BONNEY LAKE
Type of violation
ELECTRICAL CITATION
Description
Energizing electrical equipment without an
electrical inspection as referenced in WAC
296-46B-901.
Infraction no.
PBOIM00717
Issue date
07/07/2015
Violation city
BONNEY LAKE
Type of violation
PLUMBER INFRACTION
Description
Contractor advertised, offered to do work,
submitted a bid, or performed work under this
chapter without being registered as a
contractor under chapter 18.27 RCW.
Satisfied
................ _...
RCW/WAC
19.28.101 RCW
Violation amount
$250.00
Satisfied
.........................
RCW/WAC
18.106.020
Violation amount
$250.00
Workers' comp
Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums.
L&I Account ID
224,216-01
Doing business as
GREEN CITY HEATING & AIR CONDI
Estimated workers reported
Quarter 1 of Year 2018 "11 to 20 Workers"
L&I account contact
T4 / NIKKI BUTLER (360)902-4918 - Email: BUTQ235@Ini.wa.gov
Account is current.
IPublic Works Strikes and Debarments
Verify the contractor is eligible to perform work on public works projects.
Contractor Strikes
No strikes have been issued against this contractor.
Contractors not allowed to bid
No debarments have been issued against this contractor.
Workplace safety and health
No inspections during the previous 6 year period.
Page 3 of 3
Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington.
Help us improve
https://securedni.wa.gov/verify/Detail.aspx?UBI=603363739&LIC=GREENCH866B2&SAW= 5/29/2018