Loading...
HomeMy WebLinkAboutPermit M18-0069 - CITY OF TUKWILA - SPLIT SYSTEM A/C REPLACEMENTCITY OF TUKWILA 6300 SOUTHCENTER BLVD 115 M18-0069 Parcel No: Address: City of Tukwila 7 \ Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 0003200005 Permit Number: 6300 SOUTHCENTER BLVD 115 Project Name: CITY OF TUKWILA Issue Date: Permit Expires On: M18-0069 6/26/2018 12/23/2018 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: TUKWILA CITY OF 6200 SOUTHCENTER BLVD , TUKWILA, WA, 98188 DANNY DALLUM 5300 DENVER AVE S , SEATTLE, WA, 98108 ACCO ENGINEERED SYSTEMS INC (CONST) 6265 SAN FERNANDO RD , GLENDALE, CA, 91201 ACCOESI971DU 11I Phone: (206) 992-9579 Phone: (253) 854-8444 Expiration Date: 10/17/2019 DESCRIPTION OF WORK: REPLACE (2) SPLIT SYSTEM AIR CONDITIONERS WITH NEW, LIKE FOR LIKE Valuation of Work: $21,055.00 Type of Work: REPLACEMENT Fuel type: ELECT Fees Collected: $490.66 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Date: t0 --&-I U I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. - — 1 Signature: Print Name: Date: e6-26 - 236 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: Readily accessible access to roof mounted equipment is required. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: ***MECHANICAL PERMIT CONDITIONS*** 10: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 11: Manufacturers iinstallation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL CITY OF TUKWL Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA. gov Mechanical Permit No. Project No. Date Application Accepted: Date Application Expires: vt (5 — Z66( (P±(8 (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION King Co Assessor's Tax No.: 000320-0005 Site Address: 6300 SOUTHCENTER BLVD. Suite Number: 115,206 Floor: 1,2 Tenant Name: CITY OF TUKWILA PROPERTY OWNER Name: CITY OF TUKWILA Address: 6300 SOUTHCENTER BLVD 98188 City: TUKWILA State: WA Zip: 98188 CONTACT PERSON — person receiving all project communication Name: DANNY DALLUM Address: 5300 DENVER AVE S City: SEATTLE State: WA Zip: 98108 Phone: (206) 992-9579 Fax: Email: DDALLUM@ACCOSERVICE.COM New Tenant: ❑ Yes ®..No MECHANICAL CONTRACTOR INFORMATION Company Name: ACCO ENGINEERED SYSTEMS Address: 5300 DENVER AVE S City: SEATTLE State: WA Zip: 98108 Phone: (206) 787-8500 Fax: (206) 787-8501 Contr Reg No.: ACCOESi971DU Exp Date: 10/17/2019 Tukwila Business License No.: 601003669 Valuation of project (contractor's bid price): $ Describe the scope of work in detail: REPLACE (2) SPLIT SYSTEM AIR CONDITIONERS WITH NEW, LIKE EQUIPMENT. 21,055 Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement Fuel Type: Electric ill Gas ❑ Other: H:•,Applications Forms -Applications On Line`2016 ApplicationsMechanical Permit Application Revised 1-4-16.docx Revised: January 2016 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Residential, Nighttime Furnace >100k btu Industrial Floor furnace 55 dB(A) Suspended/wall/floor mounted heater 57 dB(A) Appliance vent Commercial Repair or addition to heat/refrig/cooling system 2 Air handling unit 65 dB(A) <10,000 cfm 2 Unit Type Qty Air handling unit Residential, Nighttime >10,000 cfm Industrial Evaporator cooler 55 dB(A) Ventilation fan connected to single duct 57 dB(A) Ventilation system Commercial Hood and duct 2 Incinerator — domestic 65 dB(A) Incinerator — comm/industrial 60 dB(A) Unit Type Qty Fire damper Residential, Nighttime Diffuser Industrial Thermostat 55 dB(A) Wood/gas stove 57 dB(A) Emergency generator Commercial Other mechanical equipment 2 CONDENSER UNIT 65 dB(A) Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-10PM, Monday through Friday and 8AM-10PM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: • Warning devices; • Construction and property maintenance during the daytime hours (7am-lOpm); • Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 . ► ER 0 ` UTHORIZED AGENT: Signature: \ Date: 06/01/2018 Print Name: Mailing Address: 5300 DENVER AVE S H:\Applications •Forms -Applications On Line\2016 Applications\Mechanical Permit Application Revised I-4-16.docx Revised: January 2016 bh Day Telephone: (206) 787-8500 SEATTLE WA 98108 City State Zip Page 2 of 2 ash Register :Recei City of Tukwila DESCRIPTIONS : ACCOUNT QUANTITY PermitTRAK PAID $490.66 M18-0069 Address: 6300 SOUTHCENTER BLVD 115 Apn: 0003200005 $490.66 MECHANICAL $471.79 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $344.28 PLAN CHECK FEE R000.322.102.00.00 0.00 $94.36 TECHNOLOGY FEE $18.87 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R14627 R000.322.900.04.00 0.00 $18.87 $490.66 Date Paid: Friday, June 01, 2018 Paid By: ACCO ENGINEERED SYSTEMS Pay Method: CHECK 007383 Printed: Friday, June 01, 2018 3:12 PM 1 of 1 SYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project:` Citi f 0r �i.�r G�fi � Type of Inspection: 41WiiiiiitA, > ro tC.- Address: I t3 09 frit is- Date Called: _jQ/7-ifG. Special Instructions: /f%l5 Date Wanted: PP, -75 a.m p.m. Requester: r Phone No: 206, Le t3 77 Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS:nitt' , Inspector: Itj Date: /..../X.49 / i %/ fl REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit MO -COO INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Projec i or.,4,),,,,,,, pe of Inspection:cAric.r/,"(1--- Address: 6351) S<�et-Gr.e v r 13b Date Called: Special Instructions: /// dm.1 Date Wanted: 9...01_20/r,,,,_ n f _�/_ G p.m. Cw-115 Requester: , 45Q/t) Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: 0/ Date: ?_zi_ REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pro'ec oP -rt,i Type of Inspection: M, FlkfrilL 500 r� BL Date Called: Special Instructions: Date Wanted: 2Z'2-0 �--- l a.m.. p.m. i?' 512 `/ ` Requester: Phone No: Approved per applicable codes. COMMENTS: /lied (1/L0+,6 Corrections required prior to approval. 2 144 '1-I Uii tI- al- L-ct2 171; 2.04, « rb oc;G6 4r� Inspector: Date: Zoir REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Submittal Variable Speed Convertible Air Ha 3 Ton TEM6A0C36H41 S RECEIVED CITY OF TUKWILA JUN 01 2018 PERMIT CENTER REVIEWED FOR CODE COMPLIANCE APPROVED JUN 11 2018 idleity of Tukwila BUILDING DIVISION Note: The TEM6 series air handler is designed for installation in a closet, utility room, alcove, basement, crawlspace or attic. These versatile units are applicable to air conditioning and heat pump applications. Several models are available to meet the specific requirements of the outdoor equipment. d installed electric resistance heaters are available. . g frit TAG: A SAFETY WARNING Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning equipment can be hazardous and requires specific knowledge and training. Improperly installed, adjusted or altered equipment by an unqualified person could result in death or serious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. August 2015 TEM6A0C36-SUB-1A-EN ItAngersollRand Outline Drawing 6.18 01.50 TRP MINIMUM UNIT CLEARANCE TABLE Air Handler Model TO SERVICE C COMBUSTIBLE CLEARANCE F MATERIAL IREOUIRED) (RECOMMENDED) SIDES 0' 2' FRONT 0' 21' BACK 0' 0' INLET DUCT 0' I' OUTLET DUCT 1'• NIA • 1' F01 THE FIRST 3 FT. OF OUTLET DUCT WHEN ELECTRIC HEATERS ARE INSTILLED: 0' AFTER THE FIRST 3 FT. L 0 c i 2.15 1./F PLCS PRODUCT DIMENSIONS Air Handler Model A B C D E F H Flow Control Gas Line Braze TEM6A0C36H315A 51.27 23.50 21.50 21.75 7.01 9.66 24.59 TXV 7/8 All dimensions are in inches 2 TEM6A0C36-SUB-1 A -EN Product Specifications MODEL TEM6A0C36H31SA RATED VOLTS/PH/HZ 208-230/1/60 RATINGS(a) See O.D. Specifications INDOOR COIL — Type Plate Fin Rows —F.P.I. 4 - 14 Face Area (sq. ft.) 4.59 Tube Size (in.) 3/8 Refrigerant Control TXV Drain Conn. Size (in.)(b) 3/4 NPT DUCT CONNECTIONS See Outline Drawing INDOOR FAN — Type Centrifugal Diameter -Width (In.) 11 X 10 No. Used 1 Drive - No. Speeds Direct - 16 CFM vs. in. w.g. See Fan Performance Table No. Motors — H.P. 1 - 1/2 Motor Speed R.P.M. Variable Volts/Ph/Hz 208-230/1/60 F.L. Amps 4.3 FILTER Filter Furnished? (c) No REFRIGERANT R -410A Ref. Line Connections Brazed Coupling or Conn. Size — in. Gas 7/8 Coupling or Conn. Size — in. Liq. 3/8 DIMENSIONS H x W x D Crated (In.) 52-3/4 x 27-1/2 x 25-1/2 Uncrated 51-3/8 x 23-1/2 x 21-1/8 WEIGHT Shipping (Lbs.) / Net (Lbs.) 155/144 (a) These Air Handlers are A.H.R.I certified with various Split System Air Conditioners and Heat Pumps (AHRI STANDARD 210/240). Refer to the Split System Outdoor Unit Product Data Guides for performance data. (5) 3/4" Male Plastic Pipe (Ref: ASTM 1785-76) (c) Remote filter required. TE M6A0C36-SUB-1 A -EN 3 Minimum Airflow CFM TEM6AOC36H31S Heater Minimum Heater Airflow CFM Nominal Airflow With Heat Pump Without Heat Pump BAYHTR1504BRKC, BAYHTR1504LUGB BAYHTR1505BRKC,BAYHTR1505LUGB 875 675 BAYHTR1508BRKC,BAYHTR1508LUGB 875 675 BAYHTR1510BRKC,BAYHTR1510LUGB 1225 825 BAYHTR1516BRKA 1325 1150 BAYHTR351OLUGC 875 675 BAYHTR3515LUGC 1250 1150 BAYHTR1522BRKA 1325 1150 TEM6AOC36H31 Airflow Performance with Auxiliary Heat Airflow Settings Dip Switch Settings Nominal Airflow See following tables for heater application: - Pressure Drop for Electrical Heters - Minimum Heating Airflow Matrix (on unit nameplates) Switch 7 Switch 8 Low ON ON 696 Med-Lo OFF ON 825 Med-Hi ON OFF 1150 High OFF OFF 1298 4 TEM6A0C36-SUB-1 A -EN Heater Pressure Drop Table Airflow CFM Number of Racks Outdoor Model No. Heater Racks 1 2 3 4 Heater Mvdel No. of Racks Air Pressure Drop - Inches W.G. BAYHTR1504 1 1800 0.02 0.04 0.06 0.14 BAYHTR1505 1 1700 0.02 0.04 0.06 0.14 BAYHTR1508 2 1600 0.02 0.04 0.06 0.13 BAYHTR1510 2 1500 0.02 0.04 0.06 0.12 BAYHTR1516 3 1400 0.02 0.04 0.06 0.12 BAYHTR3510 3 1300 0.02 0.04 0.05 0.11 BAYHTR3515 3 1200 0.01 0.04 0.05 0.10 BAYHTR1522 4 1100 0.01 0.03 0.05 0.09 BAYHTR1525 4 1000 0.01 0.03 0.04 0.09 900 0.01 0.03 0.04 0.08 800 0.01 0.03 700 0.01 0.02 600 0.01 0.02 Subcooling Adjustment System Matched with: Indoor Unit Model No. Outdoor Model No. Sulbcooling 16 SEER HP - 2 ton TEM6A0C36H31 4TWR6024H1000A 4TWX6024H1000A 4A6H6024H1000A 13 Degrees 15 SEER HP - 2 ton TEM6A0B24H21 TEM6A0B30H21 4TWR5024G1000A 4A6H5024G1000A 14 Degrees 15 SEER HP - 3 ton TEM6A0B30H21 TEM6A0C36H31 TEM6A0C42H41 4TWR5036G1000A 4A6H5036G1000A 14 Degrees All other matches must be charged per the nameplate charging instructions TEM6A0C36-SUB-1 A -EN 5 Performance and Electrical Data Table 1. Air Flow Performance TEM6AOC36, TEM6AOC42 COOLING AIRFLOW PERFORMANCE, WET COIL, NO FILTER, NO HEATER OUTDOOR SPEED AIRFLOW DIP SWITCH SETTING AIRFLOW EXTERNAL STATIC PRESSURE UNITSIZESETTING (TONS) SETTING SETTING SW1 SW2 SW3 SW4 POWER 0.1 0.3 0.5 0.7 0.9 LOW 300 CFM/ ON ON OFF ON CFM 761 755 719 654 560 ton Watts 63 98 131 163 193 2.5 NORMAL 341 CFM/ ON ON OFF OFF CFM 862 861 834 781 700 ton Watts 82 120 158 196 235 HIGH 384 CFM/ ON ON ON OFF CFM 962 963 948 915 863 ton Watts 106 147 190 234 279 LOW 319 CFM/ OFF ON OFF ON CFM 961 962 947 914 862 ton Watts 106 147 189 233 279 3 NORMAL 363 CFM/ OFF ON OFF OFF CFM 1092 1093 1082 1060 1026 ton Watts 146 192 240 288 337 HIGH 408 CFM/ OFF ON ON OFF CFM 1231 1231 1221 1203 1175 ton Watts 196 249 301 353 404 LOW 315 CFM/ ON OFF OFF ON CFM 1104 1105 1094 1072 1039 ton Watts 150 197 245 293 343 3.5 NORMAL 357 CFM/ ON OFF OFF OFF CFM 1258 1258 1248 1229 1201 ton Watts 209 263 317 369 421 HIGH 402 CFM/ ON OFF ON OFF CFM 1418 1415 1401 1379 1348 ton Watts 286 347 406 462 516 LOW 308 CFM/ ton OFF OFF OFF ON CFM Watts 1238 199 1238 253 1229 306 1210 357 1182 408 4 NORMAL 350 CFM/ OFF OFF OFF OFF CFM 1412 1410 1398 1378 1349 4 NORMAL ton OFF OFF OFF OFF Watts 282 344 404 462 517 HIGH 394 CFM/ OFF OFF ON OFF CFM 1570 1528 1473 1406 1326 HIGH ton OFF OFF ON OFF Watts 393 436 466 483 488 Table 2. Air Flow Performance TEM6AOC36, TEM6AOC42 HEATING AIRFLOW PERFORMANCE, NO FILTER, NO HEATER OUTDOOR SPEED AIRFLOW DIP SWITCH SETTING AIRFLOW EXTERNAL STATIC PRESSURE UNIT SIZE (TONS) SETTING SETTING SW1 SW2 SW3 SW4 POWER 0.1 0.3 0.5 0.7 0.9 LOW 341CFM/ ON ON OFF ON CFM 860 863 838 788 707 ton Watts 77 115 154 193 232 2.5 NORMAL 379 CFM/ ON ON OFF OFF CFM 949 953 937 906 852 ton Watts 98 138 180 224 269 HIGH 417 CFM/ ON ON ON OFF CFM 1042 1046 1036 1015 980 ton Watts 122 166 212 259 308 LOW 381CFM/ OFF ON OFF ON CFM 1147 1149 1141 1123 1094 ton Watts 154 203 253 303 353 3 NORMAL 424 CFM/ OFF ON OFF OFF CFM 1277 1279 1272 1255 1228 ton Watts 204 259 314 368 421 HIGH 466 CFM/ OFF ON ON OFF CFM 1409 1409 1401 1384 1357 ton Watts 260 323 383 442 500 LOW 348 CFM/ ON OFF OFF ON CFM 1222 1224 1216 1200 1174 ton Watts 180 232 285 336 388 3.5 NORMAL 386 CFM/ ON OFF OFF OFF CFM 1361 1362 1354 1337 1310 ton Watts 240 300 358 415 471 HIGH 425 CFM/ ON OFF ON OFF CFM 1497 1478 1449 1408 1356 ton Watts 316 372 420 461 494 LOW 338 CFM/ OFF OFF OFF ON CFM 1360 1361 1353 1336 1309 ton Watts 239 299 358 415 470 4 NORMAL 375 CFM/ OFF OFF OFF OFF CFM 1511 1489 1456 1412 1355 ton Watts 325 380 426 464 493 HIGH 413 CFM/ OFF OFF ON OFF CFM 1659 1605 1535 1450 1349 ton Watts 420 463 488 494 483 6 TEM6A0C36-SUB-1 A -EN Performance and Electrical Data 1. See Product Data or Air Handler nameplate for approved combinations of Air Handlers and Heaters. 2. Heater model numbers may have additional suffix digits. Table 3. Electrical Data TEM6AOC36, TEM6AOC42 HEATER DATA Heater Model No. No. of Circuits/ Phases 240 Volt 208 Volt Capacity Heater Amps per Circuit Minimum Circuit Ampacity Maximum Overload Protection Capacity Heater Amps per Circuit Minimum Circuit Ampacity Maximum Overload Protection kW BTUH kW BTUH No Heater 4.3 * 5 15 4.3 * 5 15 BAYHTR1504BRKC BAYHTR1504LUGB 1/1 3.84 13100 16.0 25 25 2.88 9800 13..8 23 25 BAYHTR1505BRKC BAYHTR1505LUGB 1/1 4.80 16400 20.0 30 30 3.60 12300 17..3 27 30 BAYHTR1508BRKC BAYHTR1508LUGB 1/1 7.68 26200 32.0 45 45 5.76 19700 27.7 40 40 BAYHTR1510BRKC BAYHTR1510LUGB 1/1 9.60 32800 40.0 55 60 7.20 24600 34..6 49 50 BAYHTR1516BRKA Circuit 1 (a) 2/1 9.60 32800 40.0 55 60 7.20 24600 34.6 49 50 BAYHTR1516BRKA Circuit 2 4.80 16400 20.0 25 25 3.60 12300 17.3 22 25 BAYHTR1522BRKA Circuit 1 2/1 9.60 32800 40.0 55 60 7.20 24600 34.6 49 50 BAYHTR1522BRKA Circuit 2 9.60 32800 40.0 50 50 7.20 24600 34.6 43 45 BAYHTR3510LUG 1/3 9.60 32800 23.1 34 35 7.20 24600 20.0 30 30 BAYHTR3515LUG 1/3 14.40 49100 34.6 48 50 10.80 36900 30.0 42 45 * = Motor Amps a) MCA and MOP for circuit 1 contains the motor amps TE M6AOC36-SUB-1 A -EN 7 Features and Benefits • Painted metal cabinet with captured foil face insulation • 2% or less air leakage • R-4.2 Insulating Value • Multi -Position UP/Down Flow, Horizontal Left/Right • ALL Aluminum Coil with Enhanced Patented Coil Fin • Electric Heaters with polarized plug connections (sold as accessory) • R-410AThermal Expansion Valve Intertek • Variable Speed ECM Motor • Low Voltage Pigtail Connections • Draw Through Design • Horizontal Drain Pan • Single Color • Fused 24V Power • 1 year warranty • 10 -year warranty registered • Optional extended warranty available uV.�i CERTIFIED,. Q www.ahrid irectory.org Unitary Small AC AHRI Standard 210/240 Corti, alien applies only when tie complete system totsd.: xh<xRi. ram . N. d CERTIFIED,. www.ah ri d Recto ry. o rg Unitary Small HP AHRI Standard 210/240 Guthh:Awn a=,nlln oily when the ample.. system is listed v:im 04Rl. The manufacturer optimizes the performance of homes and buildings around the world. A business of Ingersoll Rand, the leader in creating and sustaining safe, comfortable and energy efficient environments, the manufacturer offers a broad portfolio of advanced controls and HVAC systems, comprehensive building services, and parts. For more information, visit www.IRCO.com. The manufacturer has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. ©2014 Trane TEM6A0C36-SUB-1A-EN 11 Aug 2015 Supersedes TEM6A0C36-SUB-1-EN (December 2014) (10IngersollRand 1 Submittal Split System Heat Pump 4TWR6024H 1000A RECEIVED CITY OF TUKWILA JUN 01 2018 PERMIT CENTER REVIEWED FOR CODE COMPLIANCE APPROVED JUN 11 2018 City of Tukwila BUILDING DIVISION gics1=310 • ,1 • • • Note: "Graphics in this document are for representation only. Actual model may differ in appearance." fr1IBOOb9 TAG: A SAFETY WARNING Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning equipment can be hazardous and requires specific knowledge and training. Improperly installed, adjusted or altered equipment by an unqualified person could result in death or serious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. February 2015 4TWR6024H-SUB-1 B -EN 401ngersoIIRand 1 e TRAM' SERVICE PANEL ELECTRICAL AND REFRIGERANT COMPONENT CLEARANCES PER PREVAILING CODES. TOP DISCHARGE AREA SHOULD BE UNRESTRICTED FOR AT LEAST 1524 (5 FEET) ABOVE UNIT. UNIT SHOULD BE PLACED 50 ROOF RUN-OFF WATER DOES NOT POUR DIRECTLY ON UNIT, AND SHOULD BE AT LEAST 305 (12') FROM WALL AND ALL SURROUNDING SHRUBBERY ON TWO SIDES. OTHER TWO SIDES UNRESTRICTED. ELECTRICAL SERVICE PANEL 22.2 (7/8) DIA. HOLE LOW VOLTAGE 28.6 (1.1/8) DIA. K.O. WIT 22.2 (7/8) DIA. HOLE IN CONTROL BOX BOTTOM FOR ELECTRICAL POWER SUPPLY L10UID LINE SERVICE VALVE, 'E' I.D. FEMALE BRAZE CONNECTION WITH I/4' SAE FLARE PRESSURE TAP FITTINGS. .0. FOR ALTERNATE ELECTRICAL ROUTING GAS LINE 1/4 TURN BALL SERVICE VALVE, 'D' I.D. FEMALE BRAZED CONNECTION 11TH 1/4' SAE FLARE PRESSURE TAP FITTING. Model Base A B C D E F G H J K 4TWR6024H 3 832 829 651 3/4 3/8 127 76 197 60 508 (32-3/4) (32-5/8) (29-3/4) (5) (3) (7-3/4) (2-3/8) (20) SOUND POWER LEVEL Model A -Weighted Sound Power Level [dB(A)] Full Octave Sound Power [dB] 63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz 4TWR6024H 71 77 72 68 68 69 60 53 47 Note: Rated in accordance with AHRI Standard 270-2008 2 4TWR6024H-SUB-1B-EN Product Specifications OUTDOOR UNIT (a) (b) 4TW R6024H 1000A POWER CONNS. — V/PH/HZ (c) 208/230/1/60 MIN. BRCH. CIR. AMPACITY 14 BR. CIR. PROT. RTG. — MAX. (AMPS) 25 COMPRESSOR CLIMATUFF®- SCROLL NO. USED — NO. STAGES 1 — 1 VOLTS/PH/HZ 208/230/1/60 R.L. AMPS (d) — L.R. AMPS 10.9 — 62.9 FACTORY INSTALLED START COMPONENTS (e) YES INSULATION/SOUND BLANKET NO COMPRESSOR HEAT NO OUTDOOR FAN PROPELLER DIA. (IN.) — NO. USED 23 — 1 TYPE DRIVE — NO. SPEEDS DIRECT— 1 CFM @ 0.0 IN. W.G. (0 2850 NO. MOTORS — HP 1 — 1/8 MOTOR SPEED R.P.M. 825 VOLTS/PH/HZ 200/230/1/60 F.L. AMPS 0.64 OUTDOOR COIL — TYPE SPINE FINT" ROWS—F.P.I. 1-24 FACE AREA (SQ. FT.) 18.75 TUBE SIZE (IN.) 3/8 REFRIGERANT CONTROL EXPANSION VALVE REFRIGERANT LBS. — R -410A (O.D. UNIT) (9) 7 LBS., 5 OZ FACTORY SUPPLIED YES LINE SIZE — IN. O.D. GAS (h) 3/4 LINE SIZE — IN. O.D. LIQ. 3/8 CHARGING SPECIFICATIONS SUBCOOLING 10°F (see Charging Info) DIMENSIONS H X W X D CRATED (IN.) 38 x 30.1 x 33 WEIGHT SHIPPING (LBS.) 208 NET (LBS.) 174 (a) Certified in accordance with the Air -Source Unitary Air -conditioner Equipment certification program, which is based on AHRI standard 210/240. (b) Rated in accordance with AHRI standard 270. (c) Calculated in accordance with Natl. Elec. Codes. Use only HACR circuit breakers or fuses. (d) This value shown for compressor RLA on the unit nameplate and on this specification sheet is used to compute minimum branch circuit ampacity and max. fuse size. The value shown is the branch circuit selection current. (e) No means no start components. Yes means quick start kit components. PTC means positive temperature coefficient starter. Optional kit shown. (0 Standard Air — Dry Coil — Outdoor (9) This value approximate. For more precise value see unit nameplate. (h) Max. linear length 60 ft.; Max. lift •— Suction 60 ft.; Max. lift — Liquid 60 ft. For greater length consult refrigerant piping software Pub. No. 32-3312-0* (* denotes latest revision). 4TWR6024H-SUB-1 B -EN 3 Mechanical Specification Options General The Outdoor Units are fully charged from the factory for up to 15 feet of piping. This unit is designed to operate at outdoor ambient temperatures as high as 115°E Cooling capacities are matched with a wide selection of air handlers and furnace coils that are AHRI certified. The unit is certified to UL 1995. Exterior is designed for outdoor application. Casing Unit casing is constructed of heavy gauge, galvanized steel and painted with a weather -resistant powder paint finish on all louvered panels and the fan top panel. The corner panels are prepainted. All panels are subjected to our 1,000 hour salt spray test . The base is made of a CMBP-G30 weatherproof material to resist corrosion. Refrigerant Controls Refrigeration system controls include condenser fan, compressor contactor and high pressure switch. High and low pressure controls are inherent to the compressor. A factory supplied liquid line drier is standard. Some models may require field installation. r J Compressor The compressor features internal over temperature, pressure protection and total dipped hermetic motor. Other features include: Centrifugal oil pump and low vibration and noise. Condenser Coil The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by louvered panels. Low Ambient Cooling As manufactured, this system has a cooling capacity to 55°E The addition of an evaporator defrost control permits operation to 40°F. The addition of an evaporator defrost control with TXV permits low ambient cooling to 30°F Thermostats—Cooling only and heat/cooling (manual and automatic change over). Sub -base to match thermostat and locking thermostat cover. Evaporator Defrost Control — See Low Ambient Cooling. Intertek Arts CERTIFIED,., c www.ahridirectory.org Unitary Small HP AHRI Standard 210/240 cnmr%aeon:eppres onp.men me complete system Ilsr;a Trane optimizes the performance of homes and buildings around the world. A business of Ingersoll Rand, the leader in creating and sustaining safe, comfortable and energy efficient environments, Trane offers a broad portfolio of advanced controls and HVAC systems, comprehensive building services, and parts. For more information, visit www.Trane.com. Trane has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. ©2015 Trane 41WR6024H-SUB-1B-EN 20 Feb 2015 Supersedes 4TWR6024H-SUB-1A-EN (December 2014) 40 Ingersoll Rand 7< Submittal REVIEWED FOR CODE COMPLIANCE APPROVED Split System Heat Pump 3 -Phase, 460V 4TWA7036A4000A RECEIVED CITY OF T KWILA JUN 01 2018 PERS d CENTER JUN 112018 City of Tukwila BUILDING DIVISION Note: "Graphics in this document are for representation only. Actual model may differ in appearance." MI800? TAG: A SAFETY WARNING Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning equipment can be hazardous and requires specific knowledge and training. Improperly installed, adjusted or altered equipment by an unqualified person could result in death or serious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. May 2016 4TWA7036A-SUB-4A-EN 4R7Ingersoll Rand. INANE SERVICE PANEL ELECTRICAL AND REFRIGERANT COMPONENT CLEARANCES PER PREVAILING CODES. TOP DISCHARGE AREA SHOULD BE UNRESTRICTED FOR AT LEAST 1521 15 FEET) ABOVE UNIT. UNIT SHOULD 8E PLACED SO ROOF RUN-OFF WATER DOES NOT POUR DIRECTLY ON UNIT, AND SHOULD 8E AT LEAST 305 (12') FROM WALL AND ALL SURROUNDING SHRUBBERY ON TWO SIDES. OTHER TWO SIDES UNRESTRICTED. ELECTRICAL SERVICE PANEL 22.2 (i/8) DIA. HOLE LOW VOLTAGE 28.6 ((-I/O) DIA. N.O. WIT 22.2 (T/8l DIA. MOLE 1N CONTROL BON BOTTOM FOR ELECTRICAL POWER SUPPLY LIQUID LINE SERVICE VALVE. 'E' I.D. FEMALE BRAZE CONNECTION WITH I/1' SAE FLARE PRESSURE TAP FITTINGS. .0. FOR ALTERNATE ELECTRICAL ROUTING GAS LINE 1/1 TURN BALL SERVICE VALVE, 'D' I.D. FEMALE BRAZED CONNECTION WITH 1/4' SAE FLARE PRESSURE TAP FITTING. Model Base A B C D E F G H 3 K 4TWA7036A 4 1147 946 870 3/4 3/8 152 98 219 86 813 70 69 (45-1/8) (37-1/4) (34-1/4) (6) (3-7/8) (8-5/8) (3-3/8) (32) Sound Power Level 2 4TWA7036A-SUB-4A-EN A -Weighted MODEL Sound Power Full Octave Sound Power(dB) Level (dB(A)] 63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz 4TWA7036A 72 74 71 72 70 69 62 59 55 2 4TWA7036A-SUB-4A-EN TRANE Product Specifications OUTDOOR UNIT (a) (b) 4TWA7036A4000A POWER CONNS. — V/PH/HZ (c) 460/3/60 MIN. BRCH. CIR. AMPACITY 8 BR. CIR. PROT. RTG. — MAX. (AMPS) 15 COMPRESSOR CLIMATUFF®- SCROLL NO. USED — NO. STAGES 1— 2 VOLTS/PH/HZ 460/3/60 R.L. AMPS (d) — L.R. AMPS 5.7 — 38 FACTORY INSTALLED START COMPONENTS (e) NO (Uses BAYKSKT263) INSULATION/SOUND BLANKET NO COMPRESSOR HEAT YES OUTDOOR FAN PROPELLER DIA. (IN.) — NO. USED 27.6 — 1 TYPE DRIVE — NO. SPEEDS DIRECT— 1 CFM @ 0.0 IN. W.G. (f) 3700 NO. MOTORS — HP 1-1/8 MOTOR SPEED R.P.M. 825 VOLTS/PH/HZ 460/1/60 F.L. AMPS 0.40 OUTDOOR COIL — TYPE SPINE FIN" ROWS—F.P.I. 1-24 FACE AREA (SQ. FT.) 30.79 TUBE SIZE (IN.) 3/8 REFRIGERANT CONTROL EEV REFRIGERANT LBS. — R -410A (O.D. UNIT) (9) 10 LBS., 8 OZ FACTORY SUPPLIED YES LINE SIZE — IN. O.D. GAS NO) 3/4 LINE SIZE — IN. O.D. LIQ. 3/8 CHARGING SPECIFICATIONS SUBCOOLING 9°F DIMENSIONS H X W X D CRATED (IN.) 51.0 x 38.7 x 35.1 WEIGHT SHIPPING (LBS.) 307 NET (LBS.) 257 (a) Certified in accordance with the Air -Source Unitary Air -conditioner Equipment certification program, which is based on AHRI standard 210/240. (b) Rated in accordance with AHRI standard 270. (c) Calculated in accordance with Natl. Elec. Codes. Use only HACR circuit breakers or fuses. (d) This value shown for compressor RLA on the unit nameplate and on this specification sheet is used to compute minimum branch circuit ampacity and max. fuse size. The value shown is the branch circuit selection current. (e) No means no start components. Yes means quick start kit components. PTC means positive temperature coefficient starter. Optional kit shown. (f) Standard Air — Dry Coil — Outdoor (0) This value approximate. For more precise value see unit nameplate. (h) Reference the outdoor unit ship -with literature for refrigerant piping length and lift guidelines. Reference the refrigerant piping software pub # 32-3312-xx or refrigerant piping application guide SS- APG006-xx for long line sets or specialty applications (xx denotes latest revision). () Trane outdoor condensing units are factory charged with the system charge required for the outdoor condensing unit and 15 feet of tested connecting lines. If connecting line length exceeds 15 feet, then final refrigerant charge adjustment is necessary. Each additional foot over 15 feet requires 0.6 ozs of refrigerant. See the Installer's Guide for full charging instructions. 4TWA7036A-SUB-4A-EN 3 TRANE Mechanical Specification Options General The Outdoor Units are fully charged from the factory for up to 15 feet of piping. This unit is designed to operate at outdoor ambient temperatures as high as 115°E Cooling capacities are matched with a wide selection of air handlers and furnace coils that are AHRI certified. The unit is certified to UL 1995. Exterior is designed for outdoor application. Casing Unit casing is constructed of heavy gauge, galvanized steel and painted with a weather -resistant powder paint finish on all louvered panels and the fan top panel. The corner panels are prepainted. All panels are subjected to our 1,000 hour salt spray test . The base is made of a CMBP G30 weatherproof material to resist corrosion. Refrigerant Controls Refrigeration system controls include condenser fan, compressor contactor and high pressure switch. High and low pressure controls are inherent to the compressor. A factory supplied liquid line drier is standard. Some models may require field installation. Compressor The compressor features internal over temperature, pressure protection and total dipped hermetic motor. Other features include: Centrifugal oil pump and low vibration and noise. Condenser Coil The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by louvered panels. Low Ambient Cooling As manufactured, this system has a cooling capacity to 55°E The addition of an evaporator defrost control permits operation to 40°E The addition of an evaporator defrost control with TXV permits low ambient cooling to 30°E Thermostats—Cooling only and heat/cooling (manual and automatic change over). Sub -base to match thermostat and locking thermostat cover. Evaporator Defrost Control — See Low Ambient Cooling. Intertek tiM CERTIFIED,a, c www.ahritlirectory.org Unitary Small HP AHRI Standard 210/240 Cen!fcalien aa:aes only when the ccmplele slsmm Is I'.slea w�L�Htlel. Trane optimizes the performance of homes and buildings around the world. A business of Ingersoll Rand, the leader in creating and sustaining safe, comfortable and energy efficient environments, Trane offers a broad portfolio of advanced controls and HVAC systems, comprehensive building services, and parts. For more information, visit www.Trane.com. Trane has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. ©2016 Trane 4TWA7036A-SUB-4A-EN 17 May 2016 Supersedes (New) ateIngersoll Rand. SUBMITTAL DATA JOB NAME ARCHITECT ENGINEER LOCATION SUBMITTED BY APPROVED BY PERFORMANCE AT SPECIFIED CONDITIONS° MODEL (HEAT PUMP) (Insert Complete Model Number) VOLTS PH. Hz. MATCHED AIR HANDLER (Insert Complete Model Number) VOLTS PH. Hz. COOLING CAPACITY, Total BTUH Sensible BTU H ENTE RING MR (Evaporator) °F Dry Bulb °F. Wet Bulb LEAVING AIR (Indoor Evaporator) °F. Dry Bulb °F. Wet Bulb LOW AMBIENT COOLING °F. Outdoor Inches w.g. AIR FLOW CFM@ ENTERING AIR (Condenser) °F Dry Bulb °F Wet Bulb HEATING CAPACITY. Total BTUH (Supplementary Heat Not Included) ENTERING AIR (Indoor Unit) °F Dry Bulb ENTERING AIR (Outdoor Unit) °F. Dry Bulb SUPPLEMENTARY HEAT CAPACITY BTUH KW °installation to be in accordance with recommendations. Manufacturers CERTIFICATION Dimensions, Specification, and Performance as indicated on this sheet certified correct. (Company Name) (Location) By Date CENTRAL AIR CONDITIONING DEPARTMENT, TYLER, TEXAS 75711 GENERAL PRO DATA SPLIT SYSTEM WEATHERTRON® T PUMPS REVIEWED CODE CO APP( RU 62,000 BTUH AT RATING CONDITIONS JUN 11 2018 City of Tukwila BUILDIIa U tV BW R718A—A BWR724A—A BWR730A-A BWR736 BWR742A—A BWR748,048A—RIT CENTER BWR760,060A A RECEIVED 'CITY OF TU CWILA ,o3sa—A... JUN 01 -2018 2 3 4 5 6 7 8 OUTLINES BWR718A,724A—A 9 BW R730,736,036A—A 10 BWR742,748,048 960,060A—A 11 FEATURES 12 M(9LO69 ELECTRIC All equipment described herein is eligbte for coverage under the General Electric Central Air Conditioning Service Agreement Program. Contact your local General Electric representative for additional information. PUB. NO. 22-1160-1 October, 198C GENERAL ELECTRIC PRODUCT DATA CENTRAL AIR CONDITIONING DEPARTMENT, TROUP HIGHWAY. TYLER, TEXAS 75711 PRODUCT SPECIFICATIONS 00060k#0:: BWR710A1004. POWER CORNS. -- V/Ph/Hz Min. Brch. Cir. AmpacitY [3] Fuse Size - Max.(Amps) Fuse Size - Recmd. (Ames) Sound Ratins No. [2l COMPRESSOR No. Used - No. Speeds Volts/Ph/Hz. R.L. Asps - L.R. Amps Brch. Cir. Se1ec. Cur. Amps 230/1/60 12 20 20 19 Clisatuff - TM 1 - 1 230/1/60 8.4 - 36 8.3 OUTDOOR FAN -- Type Dia. (in.) - No. Used Type Drive - No. Seeds CFM 8 0.0 in. w.s. (43 No. Motors - HP Motor Speed R.P.M. Volts/Ph/Hz F.L. Asps - L.R. Asps PROPELLER 18 - 1 DIRECT - 1 2800 1 - 0.20 1155 230/1/60 1.2 - 3.2 OUTDOOR COIL -- Type Rows - F.P.I. Face Area Om. ft.) Tube Size (in.) Refriserant Control SPINE FIN 1 - 20 14.5 0.38 EXPANSION VALVE . REFRIGERANT Lbs. -- R-22 40.D. Unit) (53 Factory Supplied Line Size - in. O.D. Gas [6] Line Size - in. 0.D. Lit. [6] DIMENSIONS Outdoor Unit - Crated (in.) Uncrated 6 YES 0.62 0.25 4x W x .5 x 25.5 x 24.5 SEE OUTLINE DRAWINGS) WEIGHT Shippins (lbs.) Net (lbs.) 166 157 OIlTDQOR . UNIT Aleft HEAT:- PUMP COILS BWR718A with RATINCS (Coolins) [1] BTUH Indoor Airflow (CFM) System Power(KW) EER RATINGS. (Utatins) [1] (Nish Temp.) BTUH System Power (KW) C.O.P. (Low Temp.) BTUH System Power (KW) C.O.P. BXA724A-Hp BXF724A-HP 16500 600 2.2 7.6 16500 2.0 2.4. 9000 .1.55 1.7 17000 625 2.2 7.7 17000 2.0 2.5 9500 1.65 1.7 BWR718A with RATINGS (Coolins) [13 BTUH Indoor Airflow (CFM) System Power (KW) EER RATINGS (Hestia') [1] (Hish Temp.) BTUH System Power (KW) C.O.P. (Low Temp.) BTU) System Power (KW) C.O.P. ,5" p OUTDOOR UNIT WITH AIR.HANDLERS BWE736C BWU0I8A BWU024A BWV018C BWV024C BRE. DWI/718G SPLIT SYSTEM 17500 650 2.2 8.0 18000 1.9 2.8 95F Cil 17000 600 2.25 7.6 18000 2.1 2.5 rS0 65 7 1.7Z V 17000 620 2.25 7.6 17000 2.05 2.4 8000 1.65 1.4 17000 600 2.2 7.7 17000 2.0 2.5 9500 1.65 1.7 17000 620 2.25 7.6 16000 1.95 2.4 8000 1.65 1.4 17000 600 2.2 7.7 17000 2.0 2.5 9500 1.65 1.7 OCakalated in accordance wNe urrendy Preying National Electric Code. et Standard M -Dry Col - Outdoor Conk slue approximate. For more Precise value see unit nameplate and service instruction. © Max. hem length 80 ft Max. tiR - Suction 60 ft 'Au. 6fl - Liquid 80 ft Max length of prec tiarged tubing 40 R. For greater length refer to Refrigerant Piping Manual Pub. No. 22-3040. BRE. BWV724G 17000 620 2.25 7.6 16000 1.95 2.4 8000 1.65 1.4 DATA SUBJECT TO CHANGE WITHOUT NOTICE GENERAL ELECTRIC PRODUCT DATA CENTRAL AIR CONDITIONING DEPARTMENT. TROUP HIGHWAY, TYLER, TEXAS 75711 PRODUCT SPECIFICATIONS .g Z ..' `F s.. '- �,'!'$ ;'F r • . z ,' ti u ''S�v'%aw+d xa t A f- to re - �Y t.+ - h "•'>i.- F. ` ... �y .;tsx Bt#t/24A1i7 =. ,....X ti z t , _ .• 7x T ,^s•P•f�i"{.i2ma.».- a..,S,r.aFt i$� )�}9 �.° POWER CONNS. -- V/Ph/Hz 230/1/60 Min. Brch. Cir. Amracity E3] 20 Fuse Size - Max.(Amrs) 30 Fuse Size - Recmd. (Amrs) 30 Sound Rating No. (23 18 COMPRESSOR Clinatuff - TM No. Used - No. Speeds 1 - 1 Volts/Ph/Hz 230/1/60 R.L. Amrs - L.R. Amrs 13.1 - 72 Brch. Cir. Selec. Cur. Amrs 14.8 OUTDOOR FAN -- Trre Dia. (in.) - No. Used 22 - 1 Tyre Drive - No. Speeds DIRECT - 1 CFM 0 0.0 in. m.o. E4] 2550 . No. Motors - HP - 1 - 0.17 • Motor Seed R.P.N. 825 Volts/Ph/Hz 230/1/60 F.L. Amrs - L.R. Amrs - I.0 - 2.0 OUTDOOR COIL -- Type Rows - F.P.I. 1'- 20 Face -Area (sa. ft.) 14.5 Tube Size (in.) 0.50 Refrigerant Control EXPANSION VALVE - - REFRIGERANT Lbs. -- R-22 (0.D. Unit) E5] 10 Factory Supplied YES Line Size - in. 0.D. Gas (6] 0.75 - Line Size - in. Q.D. Lia. (67 0.31 • DIMENSIONS H x W x D Outdoor Unit - Crated (in.) 33.25 x 34.5 x 33.5 - Uncrated SEE OUTLINE DRAWING(S) WEIGHT Shirring • (lbs.) 279 Net (lbs.) 273 is �� a ate, a . . �zz BWR724A with BXA724A-HP BXF724A-HP RATINGS (Cooling) E13 BTUH 25000 25500 Indoor Airflow (CFU) 800 800 - System Power (KW) 3.2 3.2 EER 7.8 8.0 RATINGS (Heating) (1] (High Temr.) BTUH 26500 27000 System Power (KW) 3.05 3.05 C.Q.P. 2.5 2.6 (Low Term.) BTUH 14000 14000 System Power (KW) 2.3 2.3 C.Q.P. 1.8 1.8 ;WIT .WITH Jc0 HANDLERS. BWEr BWErBNH• I BWR724A with BWE736C BWV024C BWV724G 1BWV730G l RATINGS (Cooling) E1] BTUH 30000 26000 26000 27000 Indoor Airflow (CFM) 1125 800 800 1000 System Power (KW) 3.5 3.2 3.2 3.3 EER 8.6 8.1 8.1 8.2 RATINGS (Heating) Ell (High Temp.) BTUH 30500 28000 28000 28000 System Power (KW) 2.9 3.05 3.05 2.9 C.O.P. 3.1 2.7 2.7 2.8 (Low Temp.) BTUH - 17000 15000 15000 15000 System Power (KW) -2.35 2.3 2.3 • 2.3 • C.Q.P. 2.1 1.9 1.9 1.9 ()Rated in accordance with RILL Standard 240. f Rated in accordance w(h ARL Standard 270. SPLIT SYSTEM ®CalcuIated m accordance +pith currently praranng National Electric Code. °.Standard Air - Ory Cod - Outdoor ©Thio value approximate. For more precise value see wan nameplate and serice:etnrctian. © Max. linear length 80 ft Max. Wt - Sucsian 601t Max. lit - Liquid 60 It. Max. length of prectarged tubing 40 ft. For greater length refer b Refrigerant Piping Manual Pub. No. 22-3040. DATA SUBJECT TO CHANGE WITHOUT NOTICE 3 GENERAL ELECTRIC PRODUCT DATA CENTRAL MI? CONDITIONING DEPARTMENT, TROUP HIGHWAY, TYLER, TEXAS 75711 PRODUCT SPECIFI @Rated In accordance of& 11.81 Standard 270. SPLIT SYSTEM C) t alaiaiad in accordance rah currently prevailing National Electric Code. O+ Standard Air -- Dur Cal -Outdoor 0 This value appoouanaie. For more precise value see link nameplate and service instruction. ©Max. linear long% 80 ft Max. ift - Suction 60 It; Max. Bt - Liquid 60 ft. Max. length of precharged tubing 40 R. For greater length refer to Refrigerant Piping Manual Pub. No. 22-3040. 4 DATA SUBJECT TO CHANGE WITHOUT NOTICE .w. UWIT } '. ":'v,( - . c � :... sJ.�a3 r k �i POWER COWS. -- V/Ph/Hz Min. Brch. Cir. AmracitY E3] Fuse Size - Max.(Amrs) Fuse Size - Recmd. (Amrs) Sound Ratios No. EZ] lj.�#s 230/1/60 22 30 30 19 COMPRESSOR No. Used - No. Sreeds Volts/Ph/Hz R.L. Amps - L.R. Amps Brch. Cir. Sclec. Cur. Amrs Climatuff - TM ' 1 - 1 230/1/60 14.8 - 72 16.1 OUTDOOR FAN -- Type Dia. (in.) - No. Used Tyre Drive - No. Sreeds CFM e 0.0 in. w.s. (43 No. Motors - HP Motor Breed R.P.M. Volts/Ph/Hz F.L. Amrs -.L.R. Amrs 22 - 1 DIRECT - 1 2800 1 - 0.17 825 230/1/60 1.0 - 2.0 . OUTDOOR COIL -- Tyre Rows - F.P.I. Face Ares (ss. ft.) Tube Size (in.) Refriserant Control SPINE FIN 1 - 20 17.5 0.50 . EXPANSION VALVE REFRIGERANT Lbs. -- R -ZZ (0.D. Unit) (53 Factory Surrlied Line Sizs - in. O.D. Gas Cbl Line Size - in. O.D. Lia. (63 11 YES - 0,75 ' 0.31 • DIMENSIONS Outdoor Unit - Crated (in.) Uncrated H x W x 0 ' 37:25 x 34.5 x 33.5 SEE'OUTLINE DRAWING(S) ' WEIGHT Shirring (lbs.) Net (lbs.) • 297 283 il4ii:' t a r^ . 3Y6E i[ !• �'ilk .; . e >9 �aC 3`„ " ,. ✓ " , se ,- �,, .�� Cr r. .. .a yam.. ,n$i,.i,.= •o`r .. BWR730A BXA748A-HP . ;,:HP �XE736A-HP RATINGS T oe ins) Ell BTUH Indoor Airflow (CFM) System Power (KW) EER RATINGS (Hsatins) (13 - (Hish Tear.) BTUH System Power (KW) C.O.P. (Low Temp.) BTU)) System Power (KW) C.O.P. 32000 1200 3.9 8.2 32500 3.4 2.8 17000 2.7 1.8 32500 1200 3.9 8.3 33000 3.3 2.9 17500 2.7 1.9 30500 1125 3.85 7.9 32000 3.6• 2.6 17000 2.8 1.8 ' - ' OUTDOOR UNIT WITH AIR HANDL,Efi " ; BWR730A with BWE736C BWH742D BWE,BWHs BWV730C ,RATINGS (Cooling) E1] BTUH Indoor Airflow (CFM) System Power (KW) EER RATINGS tHeatins) Ell (Hish Tear.) BTUH Systes Power (KW) C.O.P. (Low Te.,.). BTUH System Power (KW) C.O.P. 33500 1250 3.9 8.6 34000 3.2 3.1 18000 2.55 2.1 33000 1200 3.95 8.4 34000 3.55 2.8 19000 2.7 2.1 31500 1000 3.75 8.4 33000 3.5 2.8 18500 2.75 2.0 ' - @Rated In accordance of& 11.81 Standard 270. SPLIT SYSTEM C) t alaiaiad in accordance rah currently prevailing National Electric Code. O+ Standard Air -- Dur Cal -Outdoor 0 This value appoouanaie. For more precise value see link nameplate and service instruction. ©Max. linear long% 80 ft Max. ift - Suction 60 It; Max. Bt - Liquid 60 ft. Max. length of precharged tubing 40 R. For greater length refer to Refrigerant Piping Manual Pub. No. 22-3040. 4 DATA SUBJECT TO CHANGE WITHOUT NOTICE GENERAL ELECTRIC PRODUCT DATA CENTRAL AIR CONDITIONING DEPARTMENT, TROUP HIGHWAY, TYLER, TEXAS 75711 PRODUCT SPECIFICATIONS OUTDOOR UNIT BWR736A100A ' -,434111036A300A BWRO36A400A POWER GOWNS. -- V/Ph/Hz Min. Brch. Cir. Amracity (31 Fuse Size - Max.(Amrs) Fuse Size - Recent). (Amps) Sound Ratins No. (2) 230/1/60 26 40 40 19 200-230/3/60 17 25 25 19 460/3/60 10 15 15 20 COMPRESSOR Climatuff - TM Climatuff - TM Climatuff - TM No. Used - No. Speeds 1 - 1 1 - 1 1 - 1 Volts/Ph/Hz 230/1/60 200-230/1/60 460/3/60 R.L. Asps - L.R. Amps 16.8 - 102 11.9 - 100 6.0 - 42 Brch. Cir. Selec. Cur. tors 18.6 11.9 6.0 OUTDOOR FAN -- Tyre Dia. tin.) - No. Used 22 - 1 22 - 1 22 - 1 Tyre Drive - No. Speeds DIRECT - 1 DIRECT - 1 DIRECT - 1 CFM 0 0.0 in. v.s. [4] 3300 3300 3300 No. Motors - HP 1 - 0.33 1 - 0.33 1 - 0.33 Motor Speed R.P.M. 825 025 865 Volts/Ph/Hz 230/1/60 230/1/60 460/1/60 F.L. Aars - L.R. Asps 1.4 - 3.9 1.4 - 3.9 1.3 - OIiTDOOR COIL -- Tyre SPINE FIN SPINE fFIN SPINE FIN Rows --F.P.I. 1 - 20 1 - 20 1 - 20 Face Area (ss. ft.) 17.5 17.5 17.5 Tube Size (in.) 0.50 0.50 0.50 Refriserant Control EXPANSION VALVE EXPANSION VALVE EXPANSION VALVE REFRIGERANT Lbs. -- R -2Z (0.D. Unit) [5] 11 11 10.5 Factory Supplied TES TES YES Line Size - in. 0.D. Gas (6) 0.86 0.88 0.88 Line Size - in. O.D. Lia. [6] 0.31 0.31 0.31 DIMENSIONS H x W x D H x W x D . H x W x D Outdoor Unit - Crated (in.) 37.25 x 34.5 x 33.5 36 x 32 x 33 36 x 32 x 33 Uncrated SEE OUTLINE DRAWING(S) SEE OUTLINE DRAWINGS) SEE OUTLINE DRAWING(S) WEIGHT Shirrins (lbs.) 363 303 303 Net (lbs.) 289 289 289 OUIDUfl8i, UNIT WITH' HEAT P MIP'¢ • ,` � t ' ' x BWR736A with BXA748A-HP BXA760A-HP BXF736A-HP RATINGS (Coolins) (13 BTUH 38000 39000 36000 Indoor Airflow (CFM) 1425 1400 1300 Srstes Power (KW) 4.7 4.7 4.4 EER 8.1 8.3 8.2 RATINGS (Heatins) [1] tHisb Temp.) STUN 38000 39000 39000 System Power (KW) 4.3 4.25 4.3 C.O.P. 2.6 2.7 2.7 (Low Tem►.) STUN 18500 21000 22000 System Power (KW) 3.2 3.3 3.3 C.O.P. 1.7 1.9 1.9 -<. OUTDOOR UNIT i. WITH MR:HANDLERS - '`- BWErBWHr OWN, BWR736A with BWE736C 11887421) BWV736C 8WV742G RATINGS (Coolins) Ill BTUH -- 40000 38000 36000 36000 Indoor Airflow (CFM) 1400 1350 1300 1300 Srstes Power (KW) 4.7 4.65 4.4 4.4 EER 8.5 8.2 8.2 8.2 RATINGS (Hestia.) [17 (Hish Temr.) BTUH 39000 40000 39000 39000 System Power (KW) 3.95 4.4 4.3 4.3 C.O.P. 2.9 2.7 2.7 2.7 (Low Tear.) BTUH 22000 23000 22000 22000 Srstes Power (KW) 3.1 3.25 3.3 3.3 ' C.O.P. 2.1 2.1 1.9 1.9 0 Rated in accordance with A.RJ. Standard 240. 0 Rated in accordance with A.Rl Standard 270. SPLIT SYSTEM 0 Calculated in accordance wdh asrenlly prevailing National Electric Code. O Standard A -- Dry Cod - Outdoor ®This value approximate. For more precise valve see unli rhe and service inatbuction. ®Max. linear length 80 ft Max Ht - Suction 6O ft Max. f1t - lag(ud 60 It Max. length of prediarged tubing 40 ft. For greater length refer to Refrigerant Piping Manual Pub. No. 22-3040. DATA SUBJECT TO CHANGE WITHOUT NOTICE 5 GENERAL ELECTRIC PRODUCT DATA CENTRAL AIR CONDITIONING DEPARTMENT, TROUP HIGHWAY, TYLER. TEXAS 75711 PRODUCT SPECIFICATIONS as TDDOR.; UNIT 8WR742A 00q t• _ POWER CONNS. -- V/Ph/Hz Min. Brch. Cir. Amracity 131 Fuse Size - Max.(Amrs) Fuse Size - Recmd. (Amps) Sound Ratins No. E2] 230/1/60 29.5 50 50 • 20 COMPRESSOR Climatuff - TM No. Used - No. Speeds 1 - 1 Volts/Ph/Hz 230/1/60 R.L. Amps - L.R. Amps 20.7 - 103 Brch. Cir. Selec. Cur. Amps 21.8 OUTDOOR FAN -- Tyre Dia. (in.) - No. Used 22 - 1 Type Drive - No. Speeds DIRECT - 1 CFM 8 0.0 in. w.s. 141 3800 No. Motors - HP 1 - 0.33 . Motor Speed R.P.M. 865 Volts/Ph/Hz 230/1/60 F.L. Asps - L.R. Amps 1.3 - 3.9 • OUTDOOR COIL -- Tyre • SPINE FIN Rows - F.P.I. 1 - 20 Face Area (sit. ft.) 21.3 • Tube Size (in.)0.50 _ Refriserant Control EXPANSION VALVE REFRIGERANT Lbs. -- R-22 (O.D. Unit) (5] 11 Factory Surrlied • TES Line Size - in. O.D. Cas I61 0.88 Line Size - in. O.D. Lis. 161 0.31 DIMENSIONS M x W x D . Outdoor Unit - Crated (in.) 41.5 x 34.5 x 33.5 Uncrated SEE OUTLINE DRAWING(S) WEIGHT Shirrins (lbs.) 311 Net (lbs.)305 . .§. .. • • f : M� Y.'.d 9 q * i ' a k. .'�ns "' trt4'-3' ' BWR742A with RATINGS (Co_olins) (13 BXA748A-HP BXA760A-HP BXF760A-HP ' �" H 41000 41000 42016 Indoor Airflow (CFM) 1525 1525 1400 System Power (KW) 5.1 5.0 5.4 EER 8.0 8.2 7.8 RATINGS (Hestina) (13 (Nish Temp.) BTUH 44000 44000 48000 System Power (KW) 4.7 4.6 4.8 C.O.P. 2.7 2.8 2.9 tt.ow Temp.) BTUH 25000 25000 27000 System Power (KW) 3.7 3.7 3.8 C.O.P. 2.0 2.0 2.1 OUTDOOR UNIT WITH A'R HANDLERS. BWH, BWR742A with BWE060C BWE742C BWH760D BWV742G RATINGS (Coolins) [1] 46000 42000 42000 40000 Indoor Airflow (CFM) 1675 1400 1400 1400 System Power (KW) 5.5 5.1 5.1 5.3 EER 8.4 8.2 8.2 7.5 RATINGS (Heatins) I1] (Nish Temp.) BTUH 47000 45000 45000 46000 System Power (KW) 4.3 4.6 4.6 5.1 C.O.P. 3.2 2.9 2.9 2.6 (Low Temp.) DTUH 25500 25500 25500 24500 System Power (KW) 3.5 3.7 3.7 4.0 C.O.P. 2.1 2.0 2.0 1.8 W Rated to accordance with A.R.L Stallard 240. ©Rated in accordance wdh ARI Standard 270. SPLIT SYSTEM ® Calculated in accordance wdh amenity prevailing National Becht Code. © Standard Air - Dry Cal - Outdoor ()This value approximate. For more precise value see urel nameplate and service instruction. �� © Max. bear length 80 ft; Max. Bt - Suction 60 ft; Max. Bt - liquid 60 ft. Max. length of precharged tubing 40 ft. For greater length refer to Refrigerant Piping Manual Pub. No. 22-3040. 6 DATA SUBJECT TO CHANGE WITHOUT NOTICE GENERAL ELECTRIC PRODUCT DATA CENTRAL AIR CONDITIONING DEPARTMENT, TROUP HIGHWAY, TYLER, TEXAS 75711 PRODUCT SPECIFICATIONS 0004S(IT . • .. B1 R 4BA100A 2 1A464A3613*- BNRo4eA4i► POWER CONNS. -- V/Ph/Hz Min. Brcb. Cir. Am►acitr (3) Fuse Size - Nax.(Ao►s) Fuse Size - Recod. Maps) Sound Rating No. (2) 230/1/60 32 50 50 20 200-230/3/60 22 40 40 20 460/3/60 11 15 15 20 COMPRESSOR Cliwatuff - TM Climatuff - TM Ciiaatuff - TM No. Used - No. Speeds 1 - 1 1 - 1 1 - Volts/Ph/Hz 230/1/60 208-230/3/60 460/3/60 R.L. AMPS - L.R. Aa►s 23.4 - 143 16.8 - 117 8 - 51 Brch. Cir. Selec. Cur. Amps 23.8 516.8 8 OUTDOOR FAN -- Tyre Dia. (in.) - No. Used 22 - 1 22 - 1 22 - 1 Tyre Drive - No. Speeds DIRECT - 1 DIRECT - 1 DIRECT - 1 CFM 8 0.0 in. w.s. E43 3700 3700 3700 No. Motors - HP 1 - 0.33 1 - 0.33 1 - 0.33 Motor Speed R.P.M. 825 825 865 Volts/Pb/Hz 230/1/60 230/1/60 460/1/60 F.L. Amps - L.R. Amps 1.3 - 3.9 . 1.3 - 3.9 1.2 - 2.1 OUTDO6R COIL -- Type SPINE FIN SPINE FIN SPINE FIN Rows - F.P.I. 1 - 20 1 - 20 1 - 20 Face Area (ss. ft.) 21.3 21.3 21.3 Tube Size tin.) 0:50 0.50 0.50 Refrigerant Control - EXPANSION VALVE EXPASION VALVE EXPANSION VALVE REFRIGERANT Lbs. -- R-22 (O.D. Unit) (5) 11.5 11.5 11.5 Factor., Supplied YES YES YES Line Size - in. 0.D. Gas (6) 1.12 1.12 1.12 Line Size - in. 0.D. Lia. I61 0.38 0.38 0.38 DIMENSIONS H x W x D H x W m D H x W x D Outdoor Unit - Crated tin.) 41.5 x 34.5 x 33.5 39.5.x 32 x 34 39.5 x 32 x 34 Unrated SEE OUTLINE DRAWINC(S) SEE OUTLINE DRAWINC(S) SEE OUTLINE DRAWINC(S) WEIGHT Shi _ tlbs.) 311 296 296 Net (lbs.) 305 289 209 ^ �u. ^:� '. y \'~oriSf'. `fit �. f'. ": 'i^".. ...f§3Y.f�•`t�`Y ,. a�-. �ni�hy k- h:'°vY` r4:i-- '' 4` .a�S.F aA t `,.$lx x'}:'' J. 11WR748A with BXA748A-HP BXA760A-HP BXF760A-HP RATINGS tCoolins) (13 ' STUN 47000 47000 47000 Indoor Airflow (CFM) 1730 1750 1750 System Power (114) 6.0 5.9 6.0 EER 7.8 8.0 7.8 RATINGS (Heatinsl (1) IHisb Tom.) MUM 50000 50000 51000 System Power (KW) 5.2 5.1 5.1 C.O.P. 2.8 2.9 2.9 Mow Temp.) BTUH 27000 27500 30000 System Power (KW) 3.9 3.85 4.2 C.O.P. 2.0 2.1 2.1 -UNITHInitit . < ..<,L ,IIx 1A. sF .RT Y :• BWR748A with BWE060C BWE748C JUE760C 011H7608 RATINGS (Cooling) (13 BTUH 48000 48000 48000 48000 Indoor Airflow /CFM) 1600 1600 1600 1800 System Power (KW) 6.0 6.0 6.0 6.1 EER 8.0 8.0 8.0 7.9 . RATINGS (Heatinsl E113 tHish Teem.) BTUH 51000 51000 51000 51000 '. System Power (KW/ 5.1 5.1 5.1 5.2 C.O.P. 2.9 2.9 2.9 2.9 (Low Temp.) BTUH 28000 28000 28000 28000 System Power (KW/ 3.9 3.9 3.9 4.0 C.O.P. 2.1 2.1 2.1 2.1 ()Rated in accordance wfth A.R.I. Standard 240. ()Rated in accordance with MI. Standard 270. SPLIT SYSTEM OO Calculated in accordance with currently armoring National Electric Code. ()Standard M - Dry Cpl - Outdoor ©This value approximate. For more precise value see unt nameplate and service instruction. ©Max. bear length 80 ft Max. RR - Suction DO It Max. NI - timid 60 ft. Max. length of precbarged tubing 40 ft. For greater length refer to Refrigerant (raping Manual Pub. No. 22-3040. DATA SUBJECT TO CHANGE WITHOUT NOTICE 7 GENERAL ELECTRIC PRODUCT DATA CENTRAL AIR CONDITIONING DEPARTMENT, TROUP HIGHWAY, TYLER, TEXAS 75711 PRODUCT SPECIFICATIONS OUTDOOR UNIT BWR760A100A 11II8860A3011A BWR060A40011 POWER CONKS. -- V/Ph/Hz Min. Brch. Cir. Amracity (3) 230/1/60 45 200-230/3/60 29 460/3/60 17 Fuse Size - Max.(Amrs) 60 45 25 Fuse Size - Recmd. (Amis) 60 45 25 Sound Rating No. (23 20 21 P1 COMPRESSOR Climatuff - TM Climatuff - TM Climatuff - TM No. Used - No. Sreeds 1 - 1 1 - 1 1 - 1 Volts/Ph/Hz 230/1/60 200-230/3/60 - 460/3/60 R.L. Amrs - L.R. Amts 30 - 148 21 - 128 10 - 63 Brch. Cir. Selec. Cur. Amrs 34 21 10.3 OUTDOOR FAN -- Tyre Dia. (in.) - No. Used 22 - 1 22 - 1 22 - 1 Tyre Drive - No. Sreeds DIRECT - 1 DIRECT - 1 DIRECT - CFM @ 0.0 in. w.,. (43 4600 4600 4600 Mo. Motors - HP 1 - 0.5 1 - 0.5 1 - 0.5 Motor Sneed R.P.M. 1140 1140 1150 Volts/Ph/Hz 230/1/60 230/1/60 460/1/60 F.L. Anrs - L.R. Mss 2.3 - 5.9 2.3 - 5.9 1.3 - 4.6 OUTDOOR COIL -- Ty►e SPINE FIN SPINE FIN SPINE FIN Rows - F.P.I. 1 - 20 Face Area (st. ft.) 21.3 21.3 21.3 Tube Size (in.) 0.50 0.50 0.50 Refrigerant Control EXPANSION VALVE EXPANSION VALVE EXPANSION VALVE REFRIGERANT Lbs. -- R-22 (0.D. Unit) E5] Factory Surrlied 12 TES 12 TES 12 TES Line Size - in. 0.D. Gas (67 1.12 1.12 1.12 Line Size - in. 0.D. Lia. 163 0.38 0.38 0.38 DIMENSIONS H x W x D H x l) x D H x W x D Outdoor Unit - Crated (in.) 41.5 x 34.5 x 33.5 40.25 x 32 x 34 40.25 x 32 x.34 Unrated SEE OUTLINE DRAWINGS) SEE OUTLINE DRAWINGS) SEE OUTLINE DRAWINGS) WEIGHT . Shirring (lbs.) 319 301 301 Net (lbs.) 312 294 294 . OU700011'.UNIT WITH MEAT44007 C01t: BWR760A with BXA760A-HP BXF760A-HP RATINGS (Cooling) 111 BUM 57000 57000 Indoor Airflow (CFM) 2000 2000 System Power (KW) 7.9 8.0 EER.- 7.2 7.1 RATINGS (Heating) E1] (Nish Tear.) BTUH 61000 62000 System Power (KW) 6.9 6.9 C.O.P. 2.6 2.6 (Low. Tem►.) BTUH 34500 38800 System Power (KW) 5.1 5.4 C.Q.P. 2.0 2.1 OUTDOOR UNIT WITH AIR H W OLERR. `.:-:: . BWR760A with BWE060C BWE760C BWH760D RATINGS (Cooling) (11 BTUH- 59000 58000 58000 Indoor Airflow (CFM) 2000 2000 1800 System Power (KW) 7.9 7.9 8.0 EER 7.5 7.3 7.3 RATINGS (Heating) (11 (High Tear.) STUN 62000 62000 62000 System Power (KW) 6.7 6.7 6.8 C.O.P. 2.7 2.7 2.7 (Low Temp.) BTUH 35500 35500 35500 System Power (KW) 5.3 5.3 5.4 C.O.P. 2.0 2.0 1.9 ®Rated In accordance with AR.L Standard 240. et Rated in accordance with ARI Standard 270. SPLIT SYSTEM ()Calculated in accordance with cuurrerdly prevaffing National Electric Code. a® Standard Air - Dry Cod - Outdoor ®This value approximate. For more precise value see unit nameplate and service instruction. ® Max. linear length 801 Max. Mt - Suction 60 (1: Max. Eft - Liquid 6011. • Max. length of prechaiged tubing 40 R For greater length refer to Refrigerant Piping Manual Pub. No. 22-3040. R DATA SUBJECT TO CHANGE WITHOUT NOTICE 8 DIA.HOLE FOR POWER WIRING In DIA. WITH RUBBER GROMMET FOR CONTROL WIRING BWR718A OUTDOOR UNIT (ALL DIMENSIONS ARE IN Nauss) 4 MOUNTING PADS PRESSURE TAPS W4' FLARE FITTINGS LIOUID UNE ONE SNOT COUPUNG MALE NALF; 6 GASLWE ONE SNOT COUPON MALE HALF. -11 From Dwg. 21C129145 Rov. 1 BWR724A OUTDOOR UNIT (ALL DIMENSIONS ARE 01 INCHES) TOP DISCHARGE AREA SHOULD BE UNRESTRICTED. UNIT SHOULD BE PLACED SO ROOF RUN OFF WATER DOES NOT POUR DIRECTLY ON %MIT.ANO SHOULD BE AT LEAST 12' FROST WALL AND ALLSURROUNDING SHRUBBERY ON MO SIDB.OTHER TWO SHIES . COMPLETELY UNOBSTRUCTED. GAS UNE COUPLING MALE HALF ME UOIND UNE COUPLING AVB X 1311 K.O. FOR SEE PHOTO BELOW VALE HALF 4 PDwERmRIHs FOR ELECTRICAL CONTROLS PRESSURE TAPS BEHIND SIDE PANEL 114' FLARE FITTU16S 718 DUL WITH �- �-ROMMET FORLIBBER --�' CONTROLWIRINS L S a s1lB 21.7/1 1 23-111 30 31 x.3-1/4 4 -11-6-112-0- A I -6112.0'11 +-1/2 kg— SEE PHOTO BELOW FOR REFRIGERANT CONTROLS BEHIND FRONT PANEL 31 1-1 1/2 From DwD. 21C125447 Rev. 1 ELECTRICAL CONTROLS REFRIGERANT CONTROLS DATA SUBJECT TO CHANGE WITHOUT NOTICE GAS UNE COUPLING MALE HALF -11 LIOUIO LINE COUPLING MALE HALF 4 PRESSURE TAPS 1/4" FLARE FITTINGS BWR730,736A OUTDOOR UNITS (ALL 01MENSHO SS ARE Di =HEM TO? DISCHARGE AREASHOULO BE URRESTRIC(EO. MDT SHOULD SERACED SO ROOF BMW FEATEN DOES ROT POUR DIRECTLY OR NIL ADO SHOULD BEAT LEAST 1rFROM RALL ADD ALL SURMISED= 1.1/8 X 1.3/8 K.O. FOR SHRU^.BERY OR WO NOES. QTHEI WM NOES SEE PHOTO BELOW POWER TARING CONPLETELYOISo fgvCTEO FOR REFRIGERANT CONTROLS BEHIND FRONT PANEL 7/8 MIRTH RUBBER I GROMMET FOR I CONTROL WIRING SEE PHOTO BELOW i FOR ELECTRICAL CONTROLS f � B!f�z BEHIND SIDE PANEL I f; :l ! .311/2I 111111 21:718 I 27.1/8 318 1- • 30 112 From Owg. 21C125447 Rev. 1 3/8 O.D. LIQUID LUNE (FEMALE CORRECTION 7/80A GAS LINE 1FBIALE CONNECTION - PRESSURE TAPS 1/4" FLARE RTTRIGS 3.1/3 283/4 - BWR036A OUTDOOR UNIT (AU. COME ARE IN INCHES) 70P DUNMIRE AREA SWAB BE -• uoUID LIRE SERVICE VALVE GAS UNE SEEV10E VALVE 1-1/8x 13/8 K.D. FOR POWER WIRING 718 DIA. WWTIN RUBBER GROMMET FOR CONTROL WIRING L0 HI 1111 'Ill- it LILJLJ' s 30 31 112 war :Nom REPLACEOS0 R00F RUNOFF ONE IITITPOURDIRECTLY ONOLUT,AIN SHOWSBEAT LEAST Ir FROM MALL ARM ALL BR SRIUMBL71Y 011TWO SIDELi 07UER 7:01 SW08 . SWEETEST OIRDISTRUCTED. k SEE PHOTO BELOW FOR REFRIGERANT CONTROLS' BEHIND FRONT PANEL SEE PHOTO BELOW FOR ELECTRICAL CIMITROLS BEHIND SIDEPANEL . I I ij II . I IIII Ii ji 24318 1 i iL 1 11 .1 3/8 I30 > 1/2 311/2 31 From Dwg. 21 C125041 Rev. 2 ELECTRICAL CONTROLS REFRIGERANT CONTROLS 10 DATA SUBJECT TO CHANGE WITHOUT NOTICE GAS L0(E COUPLING MALE HALF -11 LIQUID LINE COUPLING MALE HALF -B PRESSURE TAPS /4~ FLARE FITTINGS 3-118 31 BWR742,748,760A OUTDOOR UNITS (AU. DQAENSIONS ARE IN INCHES) TOP DISCHARGE AREA SHOULD DE UNRESTRICTED. UNITSI1AULO BE PLACED SO ROOF DUDOFF WATER DOES NOT POUR DIRECTLY ON UNTT.AHD SHOULD BEAT LEAST 1T F20:21r41.1. ARD ALL SUR000C01110 SHRU3IERY03TWO SIDES. OTHER WOSIDES SEE PHOTO BELOW cONPlETELY11L9D5TRDCIEO. FOR REFRIGERANT CONTROLS BEHIND FRONT PANEL — --,- 1.1/8 X 13/8 ILO. FOR POWER WIRING 718 DIA. WITH RUBBER,"" CROM ET FOR CONTROL WIRING 1 304/8 1.31.3/0 444i8h i I 30 •: 31: -40N 4 4-612 i' t )/2 .4 SEE PHOTO BELOW FOR ELECTRICAL CONTROLS BEHIND SIDE PANEL F 11-1C-tf-11 '1 E 11 F. 11 h....iL.. 3Y. ,..•` From Dwp. 21C125447 Rev. 1 3130.0. LIQUID UNE (FEMALE CONNECTION) 4-1130.11. GAS LONE (FEMALE CONNECTION) PRESSURE TAPS 114^ FLARE FITTINGS 1 BWRO48,060A OUTDOOR UNITS (AU. DIMENSIONS ARE DVI TNCHE91 TDPDISWA1IGEAREA SHOWN BE WRERTMLIED. Mir SHOULD BEPLACEDSO NIFRUNOFFWAiER- DOES NOT POUR DIRECTLY- ON WMT.AND SHOULD SEAT LEAST WRIER WALLAROALL SUSB BNRUBBERY 811WOA SK own 0 sums cossurartlNDISTRUCTEB. 3.18 LO Hi 31 LIQUID UNE SERVICE VALVE GAS UNE SERVICE VALYE 1•U8 X 14IOIC.0. FOR • POWER WIRING 7/8 DIA.WITH RUBBER GROMMET FOR CONTROL WIRING -,,I • ,.s1n i 30 S I 112 30-1/8 -+ 31 1 SEE PHOTO BELOW FOR REFRIGERANT CONTROLS! BEHIND FRONT PANEL SEE PHOTO BELOIRS FOR ELECTRICAL CONTROLS BEHIND SIDE PANEL 3/8 31 30 1 1 1 From Dwg. 210125041 Rev. : ELECTRICAL CONTROLS REFRIGERANT CONTROLS DATA SUBJECT TO CHANGE WITHOUT NOTICE FEATURES NEW APPEARANCE DESIGN — WEATHERTRON® HEAT PUMP — The clean lines and at- tractive ttractive champagne beige color of these new General ElPctric Weathertrone Heat Pump units blend with the architecture of the finest homes. These Weathertrone Heat Pumps are in a low profile, square cabinet with a decorative Lexan® grille. COMPRESSOR — The hermetically sealed General Electric Ciimatuffn" compressor has quality "designed in" for long lasting, reliable service. Features: Internal overload protection, internal pressure relief valve, centrifugal oil pump, special steel valves in the valve plate assembly, die- cast aluminum frame, piston and connecting rod, metal -to -glass leads with spade terminals, in- ternal spring mounts to reduce vibration and noise. PRESSURE REUEF VALVE — The compressor design incorporates the application of an inter- nal pressure relief valve. The valve operates on a pressure difference between the discharge and suction pressure to prevent compressor overloading. TOP DISCHARGE DESIGN — Air is drawn in all four sides and discharged out the top. Dis- charge air is directed upward and away from the surrounding area. The top discharge system delivers top performance, regardless of wind direction. SPINE FIN"' CONDENSER — Researched and manufactured by General Electric, the Spine Fin"' is a very efficient heat transfer device incorporating thousands of aluminum "spines" per- manently bonded to a continuous aluminum tubing. The lightweight, low -mass design permits the Spine Fin"' heat transfer surface to provide rapid heat flow from the spines. The wrap-around surface is a four-sided hollow square design, which permits air to be drawn in through all four sides of the coil. Appreciably more coil face area allows greater contact with low velocity incoming air. The wrap-around Spine Finn' condenser has only a fraction• of the brazed joints found in a con- ventional condenser coil utilizing "U" shaped return brazed joint connections, thus significantly reducing the possibility of refrigerant leaks. SWITCH -OVER VALVE — Positive acting, electrically operated for rapid, complete changeover from heating to cooling or vice -versa. PRE -CHARGED UNITS — The outdoor unit, connecting tubing and indoor unit are all factory dehydrated, evacuated, charged with an accurately measured charge of R-22 refrigerant, and sealed. The Quik -Attach fittings preserve this seal and insure a system which is dean, free from moisture and other contaminants, and which contains the precise refrigerant charge. It signifi- cantly reduces the possibility of leaks and reduces installation time considerably. LIQUID LINE DRIER — The factory installed liquid line drier guards against contamination of the system by moisture from either intemal or external sources. WEATHERPROOFED OUTDOOR UNIT — Electrical controls are mounted high in the outdoor unit, well protected by the outer cabinet shell. 12 DATA SUBJECT TO CHANGE WITHOUT NOTICE TIC P.I. Submittal r // D FOR COMPLIANCE APPROVED APPROVED JUN 11 2018 City BUIL,G Tukwila I VISION Variable Speed Convertible Air Handler 2 Ton TEM6A0B24H21 S RECEOVED CITY OFTUKWILA JUN 01 2018 PRET CENTER VU8-Oo? Note: The TEM6 series air handler is designed for installation in a closet, utility room, alcove, basement, crawlspace or attic. These versatile units are applicable to air conditioning and heat pump applications. Several models are available to meet the specific requirements of the outdoor equipment. Field installed electric resistance heaters are available. TAG: A SAFETY WARNING Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning equipment can be hazardous and requires specific knowledge and training. Improperly installed, adjusted or altered equipment by an unqualified person could result in death or serious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. August 2017 TEM6A0B24-SUB-1 B -EN (fIngersollRand. Outline Drawing NININUN UNIT CLEARANCE TABLE Air Handler Model SERVICE B CLEARANCE D (RECOMMENDED) SIDES 2' FRONT 21' BACK 0' INLET DUCT 16.50 OUTLET DUCT 4.68 NOTE: THIS UNIT IS APPROVED FOR INSTALLATION CLEARANCES TO COMBUSTIBLE MATERIAL AS STATED ON THE UNIT RATING NAMEPLATE PRODUCT DIMENSIONS Air Handler Model A B C D E F H Flow Control Gas Line Braze TEM6A0B24H21SA 46.77 18.50 16.50 16.75 4.68 7.33 20.09 TXV 3/4 All dimensions are in inches 2 TEM6A0B24-SUB-1 B -EN Product Specifications MODEL TEM6A0B24H21SA RATED VOLTS/PH/HZ 208-230/1/60 RATINGS(a) See O.D. Specifications INDOOR COIL — Type Plate Fin Rows—F.P.I. 4-14 Face Area (sq. ft.) 3.44 Tube Size (in.) 3/8 Refrigerant Control TXV Drain Conn. Size (in.)(b) 3/4 NPT DUCT CONNECTIONS See Outline Drawing INDOOR FAN — Type Centrifugal Diameter -Width (In.) 10 X 8 No. Used 1 Drive - No. Speeds Direct - 16 CFM vs. in. w.g. See Fan Performance Table No. Motors — H.P. 1 - 1/3 Motor Speed R.P.M. Variable Volts/Ph/Hz 208-230/1/60 F.L. Amps 2.8 FILTER Filter Furnished? (c) No REFRIGERANT R -410A Ref. Line Connections Brazed Coupling or Conn. Size — in. Gas 3/4 Coupling or Conn. Size — in. Liq. 3/8 DIMENSIONS H x W x D Crated (In.) 48-1/4 x 22-1/2 x 25-1/2 Uncrated 46-3/4 x 18-1/2 x 21-1/8 WEIGHT Shipping (Lbs.) / Net (Lbs.) 126/117 (a) These Air Handlers are A.H.R.I certified with various Split System Air Conditioners and Heat Pumps (AHRI STANDARD 210/240). Refer to the Split System Outdoor Unit Product Data Guides for performance data. (b) 3/4" Male Plastic Pipe (Ref: ASTM 1785-76) (c) Remote filter required. TEM6A0B24-SUB-1 B -EN 3 Minimum Airflow CFM TEM6AOB24H21S Heater Minimum Heater Airflow CFM Nominal Airflow With Heat Pump Without Heat Pump BAYHTR1504BRKC, BAYHTR1504LUGB BAYHTR1505BRKC, BAYHTR1505LUGB 550 600 BAYHTR1508BRKC, BAYHTR1508LUGB 800 600 BAYHTR1510BRKC,BAYHTR1510LUGB 825 700 BAYHTR1516BRKA 1050 850 BAYHTR3510LUGC 800 600 BAYHTR3515LUGC 900 850 TEM6AOB24H21 Airflow Performance with Auxiliary Heat Airflow Settings Dip Switch Settings Nominal Airflow See following tables for heater application: - Pressure Drop for Electrical Heters - Minimum Heating Airflow Matrix (on unit nameplates) Switch 7Switch 8 Low ON ON 601 Med-Lo OFF ON 723 Med-Hi ON OFF 851 High OFF OFF 973 4 TEM6A0B24-SUB-1 B -EN Heater Pressure Drop Table Airflow CFM Number of Racks Outdoor Model No. Heater Racks 1 2 3 4 Heater Model No. of Racks Air Pressure Drop - Inches W.G. BAYHTR1504 1 1800 0.02 0.04 0.06 0.14 BAYHTR1505 1 1700 0.02 0.04 0.06 0.14 BAYHTR1508 2 1600 0.02 0.04 0.06 0.13 BAYHTR1510 2 1500 0.02 0.04 0.06 0.12 BAYHTR1516 3 1400 0.02 0.04 0.06 0.12 BAYHTR3510 3 1300 0.02 0.04 0.05 0.11 BAYHTR3515 3 1200 0.01 0.04 0.05 0.10 BAYHTR1522 4 1100 0.01 0.03 0.05 0.09 BAYHTR1525 4 1000 0.01 0.03 0.04 0.09 900 0.01 0.03 0.04 0.08 800 0.01 0.03 700 0.01 0.02 600 0.01 0.02 Subcooling Adjustment System Matched with: Indoor Unit Model No. Outdoor Model No. Subcooling 16 SEER HP - 2 ton TEM6A0C36H31 4TWR6024H1000A 4TWX6024H1000A 4A6H6024H1000A 13 Degrees 15 SEER HP - 2 ton TEM6A0B24H21 TEM6A0B30H21 4TWR5024G1000A 4A6H5024G1000A 14 Degrees 15 SEER HP - 3 ton TEM6A0B30H21 TEM6A0C36H31 TEM6A0C42H41 4TWR5036G1000A 4A6H5036G1000A 14 Degrees All other matches must be charged per the nameplate charging instructions TEM6A0B24-SUB-1 B -EN 5 Performance and Electrical Data Table 1. Air Flow Performance TEM6AOB24, TEM6AOB30 COOLING AIRFLOW PERFORMANCE, WET COIL, NO FILTER, NO HEATER OUTDOOR UNITE (TONS) SPEED SETTING AIRFLOW SETTINGPOWER DIP SWITCH SETTING AIRFLOW EXTERNAL STATIC PRESSURE SW1 SW2 SW3 SW4 0.1 0.3 0.5 0.7 0.9 1.5 LOW 353 CFM/ ton ON ON OFF ON CFM Watts 533 52 497 78 461 104 425 130 390 157 NORMAL 401 CFM/ ton ON ON OFF OFF CFM Watts 611 65 580 95 548 125 517 155 486 185 HIGH 451CFM/ ton ON ON ON OFF CFM Watts 684 81 668 115 644 148 611 182 570 215 2 LOW 343 CFM/ ton OFF ON OFF ON CFM Watts 687 82 672 115 648 149 614 182 571 215 NORMAL 390 CFM/ ton OFF ON OFF OFF CFM Watts 789 104 798 145 780 183 735 216 663 246 HIGH 439 CFM/ ton OFF ON ON OFF CFM Watts 884 135 887 177 882 230 845 274 751 290 2.5 LOW 300 CFM/ ton ON OFF OFF ON CFM Watts 752 92 749 123 729 167 691 211 636 241 NORMAL 340 CFM/ ton ON OFF OFF OFF CFM Watts 859 128 861 172 863 211 830 242 727 268 HIGH 383 CFM/ ton ON OFF ON OFF CFM Watts 963 172 973 223 995 263 967 291 844 308 3 LOW 323 CFM/ ton OFF OFF OFF ON CFM Watts 959 169 962 217 974 263 940 297 816 311 NORMAL 367 CFM/ ton OFF OFF OFF OFF CFM Watts 1097 240 1100 296 1100 343 1034 363 858 341 HIGH 413 CFM/ ton OFF OFF ON OFF CFM Watts 1192 304 1150 331 1115 354 1031 361 856 339 (a) Factory Default Setting Table 2. Air Flow Performance TEM6A0B24, TEM6AOB30 HEATING AIRFLOW PERFORMANCE, NO FILTER, NO HEATER OUTDOOR UNIT SIZE (TONS) SPEED SETTING AIRFLOW SETTING DIP SWITCH SETTING AIRFLOW POWER EXTERNAL STATIC PRESSURE SW1 SW2 SW3 SW4 0.1 0.3 0.5 0.7 0.9 1.5 LOW 394 CFM/ ton ON ON OFF ON CFM Watts 599 58 571 88 539 117 502 146 462 175 NORMAL 448 CFM/ ton ON ON OFF OFF CFM Watts 680 72 665 109 641 145 610 178 572 209 HIGH 493 CFM/ ton ON ON ON OFF CFM Watts 748 89 746 118 682 163 545 208 326 240 2 LOW 393 CFM/ ton OFF ON OFF ON CFM Watts 785 97 790 128 773 175 735 223 674 253 NORMAL 446 CFM/ ton OFF ON OFF OFF CFM Watts 904 131 902 179 912 219 894 253 809 281 HIGH 491CFM/ ton OFF ON ON OFF CFM Watts 980 167 972 216 990 268 974 308 863 324 2.5 LOW 350 CFM/ ton ON OFF OFF ON CFM Watts 866 125 870 162 866 215 833 263 750 286 NORMAL 398 CFM/ ton ON OFF OFF OFF CFM Watts 995 171 988 222 1005 271 986 309 872 325 HIGH 437 CFM/ ton ON OFF ON OFF CFM Watts 1099 220 1086 274 1098 328 1065 362 918 353 3 LOW 338 CFM/ ton OFF OFF OFF ON CFM Watts 1010 174 1001 224 1018 275 1000 315 888 331 NORMAL (a) 384 CFM/ ton OFF OFF OFF OFF CFM Watts 1154 246 1151 312 1135 350 1066 361 905 345 HIGH 422 CFM/ ton OFF OFF ON OFF CFM Watts 1245 305 1167 322 1127 346 1067 361 927 352 (a) Factory Default Setting 1. See Product Data or Air Handler nameplate for approved combinations of Air Handlers and Heaters. 2. Heater model numbers may have additional suffix digits. 6 TEM6A0B24-SUB-1 B -EN Performance and Electrical Data Table 3. Electrical Data TEM6AOB24,TEM6AOB30 HEATER DATA Heater Model No. No. of Circuits/ Phases 240 Volt 208 Volt Capacity Heater Amps per Circuit Minimum Circuit Ampacity Maximum Overload Protection Capacity Heater Amps per Circuit Minimum Circuit Ampacity Maximum Overload Protection kW BTUH kW BTUH No Heater 2.8 * 4 15 2.8 * 4 15 BAYHTR1504BRKC BAYHTR1504LUGB 1/1 3.84 13100 16.0 24 25 2.88 9800 13.8 21 25 BAYHTR1505BRKC BAYHTR1505LUGB 1/1 4.80 16400 20.0 29 30 3.60 12300 17.3 25 25 BAYHTR1508BRKC BAYHTR1508LUGB 1/1 7.68 26200 32.0 44 45 5.76 19700 27.7 38 40 BAYHTR15106RKC BAYHTR1510LUGB 1/1 9.60 32800 40.0 54 60 7.20 24600 34.6 47 50 BAYHTR1516BRKA Circuit 1 (a) 2/1 9.60 32800 40.0 54 60 7.20 24600 34.6 47 50 BAYHTR1516BRKA Circuit 2 4.80 16400 20.0 25 25 3.60 12300 17.3 22 25 BAYHTR3510LUGC 1/3 9.60 32800 23.1 32 35 7.20 24600 20.0 28 30 BAYHTR3515LUGC 1/3 14.40 49100 34.6 46 50 10.80 36900 30.0 41 45 * = Motor Amps (a) MCA and MOP for circuit 1 contains the motor amps TEM6A0B24-SUB-1 B -EN 7 Features and Benefits • Painted metal cabinet with captured foil face insulation • 2% or less air leakage • R-4.2 Insulating Value • Multi -Position UP/Down Flow, Horizontal Left /Right • ALL Aluminum Coil with Enhanced Patented Coil Fin • Electric Heaters with polarized plug connections (sold as accessory) • R -410A Thermal Expansion Valve • Variable Speed ECM Motor • Low Voltage Pigtail Connections • Draw Through Design • Horizontal Drain Pan • Single Color • Fused 24V Power • 3 year warranty • 10 -year warranty registered • Optional extended warranty available 8 TEM6A0B24-SUB-1 B -EN ($)ingersoIi Rand® Ingersoll Rand (NYSE: IR) advances the quality of life by creating comfortable, sustainable and efficient environments. Our people and our family of brands — including Club Car®, Ingersoll Rand®, Thermo King® and Trane— work together to enhance the quality and comfort of air in homes and buildings; transport and protect food and perishables; and increase industrial productivity and efficiency. We are a global business committed to a world of sustainable progress and enduring results. Club Car (i )Ingersoll Rand. ETe THERMO KING a TRIUNE' ingerso)lrand.com Intertek Ingersoll Rand has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices. TEM6A0B24-SUB-1 B -EN 15 Aug 2017 Supersedes TEM6A0B24-SUB-1A-EN (August 2015) ©2016 Ingersoll Rand PERM1T COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M18-0069 DATE: 06/01/18 PROJECT NAME: CITY OF TUKWILA SITE ADDRESS: 6300 SOUTHCENTER BLVD - SUITES 115 & 206 X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: Building Division Public Works U NN Fire Prevention Structural Planning Division nPermit Coordinator n PRELIMINARY REVIEW: Not Applicable n (no approval/review required) REVIEWER'S INITIALS: DATE: 06/05/18 Structural Review Required DATE: n APPROVALS OR CORRECTIONS: DUE DATE: 07/03/18 Approved n Approved with Conditions n Corrections Required C Denied n (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 ACCO ENGINEERED SYSTEMS INS Washington State Department of Labor & Industries Home 1-spanol €'ontnet Safety & Health Claims & Insurance Search L&I Page 1 of 3 t kd = 1 A -Z Tndax f-Ielp TvI l &1 Workplace Rights Trades & Licensing ACCO ENGINEERED SYSTEMS INC Owner or tradesperson MARRS, JEFFREY R Principals MARRS, JEFFREY R, PRESIDENT OSIER, ROBERT, SECRETARY PETERSEN, JOHN GORDON, TREASURER KESSLER, ROBERTA A, SECRETARY (End: 02/09/2018) AVERSANO, JOHN PAUL, PRESIDENT (End: 07/17/2017) NARBONNE, PETER HENRY, VICE PRESIDENT (End: 07/17/2017) HANSEN, JOHN WALTER, VICE PRESIDENT (End: 07/17/2017) MCNAMARA, WILLIAM B, VICE PRESIDENT (End: 09/01/2004) VLICK, ROBERT P, VICE PRESIDENT (End: 10/17/2011) RICHTER, CHARLES K, VICE PRESIDENT (End: 10/17/2011) WESTPHAL, KENNETH B, VICE PRESIDENT (End: 10/17/2011) YATES, RICHARD D, VICE PRESIDENT (End: 10/17/2011) GOODMAN, MILTON L, VICE PRESIDENT (End: 10/17/2011) SMITH, STEVEN J, VICE PRESIDENT (End: 10/17/2011) KRASSENSKY, RONALD, VICE PRESIDENT (End: 10/17/2011) HAMMOND, ROBERT T, VICE PRESIDENT (End: 10/17/2011) MARRS, JEFFREY R, VICE PRESIDENT (End: 10/17/2011) LUDOLPH, DOUGLAS E, VICE PRESIDENT (End: 10/17/2011) BROWN, ROBERT A, TREASURER (End: 10/17/2011) BOYSEN, THOMAS C, SECRETARY (End: 11/06/2006) 6265 SAN FERNANDO RD GLENDALE, CA 91201 253-854-8444 Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601003669&LIC=ACCOESI971 DU&SAW= 6/26/2018 ACCO ENGINEERED SYSTEMS INC WA UBI No. Business type 601 003 669 Corporation License Verify the contractci's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. ACCOESI971DU Effective — expiration 03/31/2003— 10/.7/2019 Bond FIDELITY & DEF./SIT CO OF MD Bond account no. 08030409 Received by L&I 10/02/2001 $12,000.00 Effective date 10/01/2001 Expiration date Until Canceled Insurance Arch Insurance Co $1,000,000.00 Policy no. 71pkg8949200 Received by L&I Effective date 10/02/2017 + 10/01/2017 Expiration date 10/01/2018 .1 Insurance history Savings No savings accoucts during the previous 6 year period. Lawsuits against :.ie bond or savings No lawsuits againe•t the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts a.e recorded for this contractor license during the previous 6 year period, but some debts may be recorded Li other agencies.. License Violation/. No license viiolatic is during the previous 6 year period. Workers' c ,mp Do you know if the :,usiness has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID 386,261-00 Doing business as ACCO ENGINEER :D SYSTEMS Estimated workers -eported Quarter 1 of Year 318 "Greater than 100 Workers" L&I account contact T2 / SUSAN BETT : (360)902-4828 - Email: BETT235@lni.wa.gov Account is current. Public Woi s Strikes and Debarments Verify the contracts is eligible to perform work on public works projects. Contractor Strike: No strikes have b, 3n issued against this contractor. Contractors not a owed to bid No debarments hie been issued against this contractor. Workplace safety and health Page 2 of 3 Help us improve https://secure.lni. Na.gov/verify/Detail.aspx?UBI=601003669&LIC=ACCOESI971DU&SAW= 6/26/2018 6300 SOUTHCENTER BLVD. TUKWILA, WA 98188 BELLEVUE MECHANICAL JOB #: 1898866 • No chang. • 77 -7 - Of WOrl< , 41 Tt. MOTE: and may i, u -. l r :-J',i4w fees. -1 5300 DENVER AVE. S SEATTLE, WA 98108 (206) 787-8500 THE PLANS AND SPECIFICATIONS HEREIN ARE OWNED BY AND FOR THE SOLE USE OF ACCO ENGINEERED SYSTEMS, INC ('ACCO'), AND MAY NOT BE REPRODUCED OR USED BY OTHERS FOR ANY PURPOSE UNLESS AUTHORIZED BY ACCO IN WRITING. ACCO CANNOT ACCEPT ANY LIABILITY, WARRANTY, OR OBLIGATION IN THE EVENT OF UNAUTHORIZED USE. J S E F1'7 A+ I i.: PERMIT EQUr_7) FOR: • o0,N1:::chanical CZEEL'.ctricai liti fumbing ["I Gas Piping Lc'' y of i,. -q<% riga ll..l f ?"' i niVlsloN Plan revic.- . ° rroroand omissions. Approval c , :'.s not authorize the vioiati4„ ordinance. Receipt of approved c 1:1-1c is acknowledged: By:�,,. Date: ... ..".1JaL.2 J& �..._... BU �.►.��: :� i:; VISION EXPIRES: 11 - 28 - 2018 5300 DENVER AVE S, SEATTLE, WASHINGTON, 98108 OFFICE (206) 787-8600 HVAC LEGEND ABBREVIATIONS DUCT SYMBOL LEGEND PIPING SYMBOL LEGEND ABBRV. DESCRIPTION ABBRV. DESCRIPTION ABBRV. DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION ABBRV. ABV. A/C ABOVE AIR CONDITIONING ACCESS DOOR ADJACENT GA. GALV. GC GEN. GAUGE GALVANIZED GENERAL CONTRACTOR GENERAL P.O.C. PLUMB'G. P.S.I. POINT OF CONNECTION PLUMBING POUNDS PER SQUARE INCH (E) NEW(N) & EXISTING(E) RECTANGULAR SUPPLY AIR DUCT RISER i HVAC EQUIPMENT SCHEDULES AND GENERAL NOTES MANUAL VOLUME DAMPER AUTOMATIC AIR VENT AV A.D. ADJ. (N) '� X M0.02 SITE KLAN M2.01 (N) , (E) NEW(N) & EXISTING(E) RECTANGULAR RETURN AIR DUCT RISER .1 BDD BACKDRAFT DAMPER 4 MANUAL AIR VENT MAV A.F.F. AL ABOVE FINISHED FLOOR ALUMINUM GPM GPM GALLONS PER HOUR GALLONS PER MINUTE R RA RELOCATE RETURN AIR NEW(N) & EXISTING(E) RECTANGULAR EXHAUST AIR DUCT RISER ROOF HVAC DEMO PLAN & HVAC PLAN MOTORIZED DAMPER III UNION UNION A.P. APPROX. ACCESS PANEL APPROXIMATE BOARD BACKDRAFT DAMPER BOTTOM FLAT BUTTERFLY VALVE BOTTOM OF DUCT BOTTOM OF PIPE BALL VALVE GYP HT. HI. HR. HWR HWS I.D. IBC IMC GYPSUM HEIGHT HIGH HOUR HOT WATER RETURN HOT WATER SUPPLY INSIDE DIMENSION CODE INTERNATIONAL MBECHANICAL INTERNATIONAL MECHANICAL CODE RAR RAR RND. REQD REV. RF. SA SAG SAR RETURN AIR GRILLE RETURN AIR REGISTER ROUND REQUIRED REVISION ROOF ROOM SUPPLY AIR SUPPLY AIR GRILLE SUPPLY AIR REGISTER (N) (E) © (N) 0 0 (E) NEW(N) & EXISTING(E) ROUND AIR DUCT RISER 30-4 FSD FIRE -SMOKE DAMPER REDUCED PRESSURE BACKFLOW PREVENTER RPBP BD. BDD KIK1 120 120 ?-4 =3 SINGLE AND DOUBLE LINE ROUND DUCT, BARE SHEET METAL 3�® FDS® FIRE DAMPER `jNI SILENT CHECK VALVE CV B.F. BF.V. 120W 120W ® SINGLE AND DOUBLE LINE ROUND DUCT, WRAPPEDRM. W/ 1.5" FSK (UNLESS OTHERWISE NOTED) SD� SMOKE DAMPER Xi GATE VALVE GV B.O.D. B 0 P --� 12/12 12/12 SINGLE AND DOUBLE LINE RECTANGULAR DUCT, BARE SHEET METAL R CEILING RADIATION DAMPER GLOBE VALVE GLV B.V. ��� P� -.�� BLDG. CC CD CLG CFM CH.V. CHWR CHWS CMU CONC. CONN. CONTR. CWR CWS DMPR. DET. D/L DN. DWG E EA.EACH EC BUILDING BOTTOM CONTROLS CONTRACTOR CONDENSATE CEILING CUBIC FEET PER MINUTE CHECK VALVE CHILLED WATER RETURN CHILLED WATER SUPPLY CONCRETE MASONRY UNIT CONCRETE CONNECTION CONTRACTOR CONDENSER WATER RETURN CONDENSER WATER SUPPLY DAMPER DETAIL DOOR LOUVER DOWN DRAWING EXISTING ELECTRICAL CONTRACTOR IN. INS INT. L LBS. L.D. M.A. MAN. MAX. MC MCD MD MECH. MFR. MIN. MISC. MIL MTR. MUA MVD N INCH INSULATION INTERIOR LONG POUNDS LINEAR DIFFUSER MIXED AIR MANUAL MAXIMUM MECHANICAL CONTRACTOR MODULAR CORE DIFFUSER MOTORIZED DAMPER MECHANICAL MANUFACTURER MINIMUM MISCELLANEOUS METAL MOTOR MAKE UP AIR MANUAL VOLUME DAMPER NEW SD SEC SHT. SL SM SQ. SS STD. STRUCT. SUSP SW SWG SWR TAG T.F. T.O.D. T.O.P. TSTAT TYP• UBC U.C. U.G. SMOKE DETECTOR SEATTLE ENERGY CODE SHEET SOUND LINED SHEET METAL SQUARE STAINLESS STEEL STANDARD STRUCTURAL SUSPENDED SWITCH SIDE WALL GRILLE SIDE WALL REGISTER TRANSFER AIR GRILLE TOP FLAT TOP OF DUCT TOP OF PIPE THERMOSTAT TYPICAL UNIFORM BUILDING CODE UNDER CUT UNDER GROUND 12/12SL 12/12SL SINGLE AND DOUBLE LINE RECTANGULAR DUCT, 1"BTM. SOUND LINED (UNLESS OTHERWISE NOTED) OT THERMOSTAT XI BALL VALVE - FULL PORTED BV -- 20/124, 2O/12a &-� ® SINGLE AND DOUBLE LINE OVAL DUCT, BARE SHEET METAL O HUMIDISTAT I STRAINER STRN 12/12 12/12 EXISTING DUCTWORK TO BE DEMOLISHED �S TEMPERATURE SENSOR TP&T PRESSURE/TEMPERATURE TAP x x x x x x x )q } x 120 FLEX DUCT, 12' MAX LENGTH (UNLESS OTHERWISEDP NOTED) O DIFFERENTIAL PRESSURE SENSOR .T BULB WELL BW SINGLE & DOUBLE LINE DUCTWORK WITH TRANSITIONAL FITTING CQ CARBON MONOXIDE SENSOR PRESSURE REDUCING VALVE PRV © SQUARE TO ROUND TRANSITIONAL FITTING 0 CARBON DIOXIDE SENSOR BUTTERFLY VALVE BFV 18/18 )NEEr 0 G 0ISEI C) 90° SQUARE ELBOW WITH 90° RADIUS ELBOW TURNING VANES NO2 O NITROGEN DIOXIDE SENSOR o BUTTERFLY VALVE W/ MEMORY STOP BFVM O ROUND DUCT TURNING DN © RECT. DUCT TURNING DN ® ROTO -TWIST DAMPER F PRESSURE RELIEF VALVE RV O ` © II © DIFFUSER/GRILLETpG: (� TYPE O CFM ® SIZE ® TYPICAL OF # ® ELECTRICAL WALL SWRCH (p� Y PRESSURE GAGE PG .no © (ra, 2 O s ;I: 7; O • . SUPPLY AIR MODULAR CORE LAY -IN DIFFUSER: Q NEW © EXISTING © RELOCATE ACCESS PANEL OR DOOR 4 THERMOMETER THERM 2 O 01 ( ©4 ©V 0;:,;; /� :- -. SUPPLY AIR CEILING MOUNTED DIFFUSER: NEW © EXISTING ()RELOCATE EQUIPMENT TAG I*. BALL VALVE W/ " HOSE ADAPTOR BV W/HA VAV-1 © ELB EQUIP. EXH EXP EXT. F ELBOW EQUIPMENT EXHAUST EXPANSION EXTERIOR FUTURE N/A NC N.I.C. NO NO. N.R. NTS NOT APPLICABLE NORMALLY CLOSED NOT IN CONTRACT NORMALLY OPEN NUMBER NOT RATED NOT TO SCALE UMC U.N.O. U.T.R. V. VAV VFD VLV. UNIFORM MECHANICAL CODE UNLESS NOTED OTHERWISE UP THROUGH ROOF VENT VARIABLE AIR VOLUME VARIABLE FREQUENCY DRIVE VALVE . © 0 _ _ _ SUPPLY AIR LINEAR SLOT DIFFUSER: Q NEW © EXISTING © RELOCATE FLAG NOTE R i TWO-WAY CONTROL VALVE 2WAY 8 dO©\,;.=,,, O® - SUPPLY AIR ROUND DIFFUSER: © NEW ()EXISTING © RELOCATE POINT OF CONNECTIW THREE-WAY CONTROL VALVE 3WAY ®; : ; RETURN AIR GRILLE: Q NEW ©EXISTING ()RELOCATE ZS' REVISION DELTA GAS COCK GC 0 ©\ hi 0 _j / �i t` I� /� _ _•J . EXHAUST AIR GRILLE: Q NEW ()EXISTING Q RELOCATE Al SOLENOID VALVE SV F.C. FD FLEXIBLE CONNECTION FIRE DAMPER OBD O.C. OPPOSING BLADE DAMPER ON CENTER VSD VOL. VARIABLE SPEED DRIVE VOLUME o alFIN. DETAIL SYMBOL: 0 DETAIL NUMBER 0 SHEET NUMBER TZT CIRCUIT SETTER VALVE CS FLEX FLR FSD FT. FW FINISH FLEXIBLE FLOOR FIRE SMOKE DAMPER FOOT (FEET) FIRE WRAP O.D. OPER. OPP. OPN'G. O.S.A. OUTSIDE DIMENSION OPERATING OPPOSITE OPENING OUTSIDE AIR WMS WSEC WT. WIRE MESH SCREEN WASHINGTON STATE ENERGY CODE WEIGHT e SECTION SYMBOL: ©SECTION NUMBER ©SHEET NUMBER d p FLOW DIRECTION © ..ILII FLEX CONNECTION FLEX DRAWING SCHEDULE INDEX DRAWING INDEX KEY: ISSUE RECORD 1. PERMIT SET NOT INCLUDED WITH ISSUE NEW OR REVISED NO CHANGES DWG NO. DRAWING TITLE M0.00 COVER SHEET, DRAWING INDEX, AND SYMBOL LEGEND M0.01 HVAC EQUIPMENT SCHEDULES AND GENERAL NOTES M0.02 SITE KLAN M2.01 1ST FLOOR HVAC DEMO PLAN & HVAC PLAN , M2.02 2ND FLOOR HVAC DEMO PLAN & HVAC PLAN M2.R1 ROOF HVAC DEMO PLAN & HVAC PLAN REVIEWED FOR CODE COMPLIANCE APPROVED JUN 11 2018 I City of Tukwila BUILDING DIVISION A06/01/18 No. Date Revisions PERMIT SET Description Project 6300 SOUTHCENTER BLVD. BLDG. UNIT REPLACEMENT 6300 SOUTHCENTER BLVD. TUKWILA, WA 98188 VICINITY MAP LEGAL INFORMATIONpERMIT CEN PARCEL #: 000320-0005 LEGAL DESCRIPTION: GILLIAM W H -D C #40 POR DONATION CLAIM IN S 1/2 OF SE 1/4 OF SEC 23-23-04 DAF - BEG 1836.78 FT W & 1501.50 FT N OF COR OF SEC 23, 24, 25 & 26 TH E 350 FT TO TPOB TH E 150 FT TH S 460.15 FT M/L TO NLY MGN OF CO RD NO 622 TH WLY ALG SD RD TAP S OF TPOB TH N TO TPOB Title COVER SHEET, DRAWING INDEX, & SYMBOL LEGEND DATE: 06/01/2018 T.TOUTONGHI Designed By T.TOUTONGHI Drawn By 1898866 Job Number NONE Scale S.CAMIS Checked By D.DALLUM Project Manager 6/1/2018 Print Date FAN COIL UNIT SCHEDULE UNIT NO. AREA SERVED MFG & MODEL NO. NOMINAL TONS BLOWER ELECTRICAL WT LBS NOTES CFM SPD VOLT/PH MCA ,. c c - .. HP -1-1 FCU -1-1 LEVEL 1 SUITE 115 TRANE TEM6A0B24H21SA 3 1200 HI 208/1 4 117 2 FCU -2-1 LEVEL 2 SUITE 206 TRANE TEM6A0C36H31SA 2 800 HI 20811 27 144 2,3 NOTES: 1. DEMO EXISTING UNIT. ELECTRICAL SAFE -OFF AND DEMO REFER LINES TO STUB -OUTS PER PLANS. 2. NEW UNIT. NO ECONOMIZER PER 2015 WSEC TABLE 503.4 OPTION 2B. UNITS EFFICIANCY IS MORE THAN 10% ABOVE CODE MIN. 3. PROVIDE WITH 5KW DUCT HEATER. MECHANICAL SCOPE OF WORK REPLACE (2) EXISTING FAN COILS AND (2) EXISTING CONDENSING UNITS WITH LIKE EQUIPMENT. HVAC GENERAL NOTES HEAT PUMP CONDENSING UNIT SCHEDULE UNIT NO. AREA SERVED MFG & MODEL NO. NOM TONS SEER HSPF ELECTRICAL WT LBS NOTES VOLT/PH MCA HP -1-1 LEVEL 1 SUITE 115 TRANE 4TWR6024H1000A 2 16 9 208/1 14 174 2 HP -2-1 LEVEL 2 SUITE 206 TRANE 4TWA7036A4000A 3 17 9 460/3 15 . 257 2 NOTES: 1. DEMO EXISTING UNIT. ELECTRICAL SAFE -OFF AND DEMO REFER LINES TO STUB -OUTS PER PLANS. 2. NEW UNIT. RE -USE EXISTING ROOF SLEEPERS AND RECONNECT TO EXISTING ELECTRICAL DISCONNECT AND REFER LINES. 1. THESE PLANS ARE SCHEMATIC AND DO NOT SHOW EXACT ROUTING OR EVERY OFFSET WHICH MAY BE REQUIRED. THE HVAC CONTRACTOR IS TO COORDINATE WITH ALL OTHER TRADES AND IS TO VERIFY ALL CLEARANCES BEFORE COMMENCING WORK. 2. MATERIALS, METHODS, AND INSTALLATION SHALL COMPLY WITH THE PROVISIONS OF THE 2015 EDITIONS OF THE INTERNATIONAL MECHANICAL CODE, INTERNATIONAL BUILDING CODE, INTERNATIONAL FUEL AND GAS CODE, INTERNATIONAL FIRE CODE, AND LOCAL CODES AND ORDINANCES. 3. ZONE THERMOSTATIC CONTROLS SHALL BE CONFIGURED TO PROVIDE A DEADBAND OF 5°F WITHIN WHICH THE SUPPLY OF HEATING AND COOLING ENERGY TO THE ZONE IS SHUT OFF OR REDUCED TO A MINIMUM PER 2015 WSEC C403.2.4.1.2. 4. AUTOMATIC CONTROLS SHALL BE CAPABLE OF STARTING AND STOPPING THE SYSTEM AS REQUIRED PER 2015 WSEC C403.2.4.2. 5. SELECTED FAN MOTORS SHALL BE NO LARGER THAN THE FIRST AVAILABLE MOTOR SIZE GREATER THAN THE DESIGN BHP PER 2015 WSEC C403.2.11.2. 6. DUCT CONSTRUCTION AND HANGING SHALL COMPLY WITH SECTION 603 OF THE 2015 IMC AND WITH CURRENT SMACNA STANDARDS. EARTHQUAKE BRACE ALL DUCTS 28" DIA AND LARGER WHICH ARE SUSPENDED MORE THAN 12" BELOW STRUCTURAL SYSTEM. 7. PROVIDE EARTHQUAKE RESTRAINT FOR HVAC EQUIPMENT IN ACCORDANCE WITH SECTION 1613 OF THE 2016 IBC. 8. HVAC EQUIPMENT, VALVES, AND DAMPERS SHALL BE LOCATED IN EASILY ACCESSIBLE LOCATIONS. UNLESS SHOWN ON ARCHITECTURAL DRAWINGS, REQUIRED ACCESS PANELS SHALL BE PROVIDED AND INSTALLED BY THE GENERAL CONTRACTOR. 5300 DENVER AVE. S SEATTLE, WA 98108 (206) 787-8500 THE PLANS AND SPECIFICATIONS HEREIN ARE OWNED BY AND FOR THE SOLE USE OF ACCO ENGINEERED SYSTEMS, INC ('ACCO'), AND MAY NOT BE REPRODUCED OR USED BY OTHERS FOR ANY PURPOSE UNLESS AUTHORIZED BY ACCO IN WRITING. ACCO CANNOT ACCEPT ANY LIABILITY, WARRANTY, OR OBLIGATION IN THE EVENT OF UNAUTHORIZED USE. 9. WITHIN 90 DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE, RECORD DRAWINGS OF THE ACTUAL INSTALLATION TO BE PROVIDED TO THE BUILDING OWNER. RECORD DRAWINGS SHALL INCLUDE AS A MINIMUM THE LOCATION AND PERFORMANCE DATA ON EACH PIECE OF EQUIPMENT, GENERAL CONFIGURATION OF DUCT AND PIPE DISTRIBUTION SYSTEM INCLUDING SIZES, AND THE TERMINAL AIR AND WATER DESIGN FLOW RATES. 10. OPERATING AND MAINTENANCE MANUALS TO BE PROVIDED TO THE BUILDING OWNER THAT INCLUDE: SUBMITTAL DATA, NAMES AND ADDRESSES OF AT LEAST ONE SERVICE AGENCY, HVAC CONTROLS SYSTEM MAINTENANCE AND CALIBRATION INFORMATION, AND A COMPLETE OPERATIONAL NARRATIVE FOR EACH SYSTEM. 11. COMMISSIONING: COMMISSIONING FOR THE PROJECT SHALL MEET THE REQUIREMENTS OF THE 2015 WASHINGTON STATE ENERGY CODE, SECTION C408. SYSTEM SHALL BE TESTED TO ENSURE CONTROL DEVICES, EQUIPMENT, AND SYSTEMS ARE CALIBRATED, ADJUSTED, AND OPERATE IN ACCORDANCE WITH THE PLANS. SEQUENCES OF OPERATION SHALL BE FUNCTIONALLY TESTED TO ENSURE THEY OPERATE IN ACCORDANCE WITH THE PLANS. A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND FILED WITH THE OWNER. JUN 11 2018 A06/01/18 No. Date Revisions Project PERMIT SET Description RECEIVED CITY OF TUKWILA JUN 01 2018 PERMIT CENTER 6300 SOUTHCENTER BLVD. BLDG. UNIT REPLACEMENT 6300 SOUTHCENTER BLVD. TUKWILA, WA 98188 Title HVAC EQUIPMENT SCHEDULES & GENERAL NOTES T.TOUTONGHI Designed By T.TOUTONGHI PERMIT SET Drawn By 1898866 Job Number NONE S.CAMIS Checked By D.DALLUM Project Manager DATE: 06/01/2018 6/1/2018 Print Date 6300 SOUTHCENTER 3LVD. • HP 1-1 NEW 5300 DENVER AVE. S SEATTLE, WA 98108 (206) 787-8500 THE PLANS AND SPECIFICATIONS HEREIN ARE OWNED BY AND FOR THE SOLE USE OF ACCO ENGINEERED SYSTEMS, INC ('ACCO'), AND MAY NOT BE REPRODUCED OR USED BY OTHERS FOR ANY PURPOSE UNLESS AUTHORIZED BY ACCO IN WR/TING. ACCO CANNOT ACCEPT ANY LIABILITY, WARRANTY, OR OBLIGATION IN THE EVENT OF UNAUTHORIZED USE. • HP REVIEWED FOR CODE COMPLIANCE APPROVED JUN 11 2018 City of Tukwila BUILDING DIVISION A06/01/18 PERMIT SET No. Date Description Revisions Project • 2-1 J NEW SOUT 6300 SOUTHCENTER BLVD. BLDG. UNIT REPLACEMENT 6300 SOUTHCENTER BLVD. TUKWILA, WA 98188 Title SITE PLAN RECEIVED CITYOFTU T.TOUTONGHI Designed By T.TOUTONGHI SOUTHCENTER BLVD. 1/32" = 1'-0" Drawn By 1898866 Job Number NONE S.CAMIS Checked By D.DALLUM Project Manager DATE: 06/01/2018 Scale 6/1/2018 Print Date 5300 DENVER AVE. S SEATTLE, WA 98108 (206) 787-8500 THE PLANS AND SPECIFICATIONS HEREIN ARE OWNED BY AND FOR THE SOLE USE OF ACCO ENGINEERED SYSTEMS, INC ('ACCO'), AND MAY NOT BE REPRODUCED OR USED BY OTHERS FOR ANY PURPOSE UNLESS AUTHOR/ZED BY ACCO IN WRITING. ACCO CANNOT ACCEPT ANY LIABILITY, WARRANTY, OR OBLIGATION IN THE EVENT OF UNAUTHORIZED USE. Ni = CONNECT=:NEW ;:FAN-COIL::TO-:-= CD. AND REFER LINES STUBOUTS EXISTING CD. LINE TO APPROVED LOCATION EXISTING REFRIGERANT LINES UP TO ROOF DEMO EXISTING FAN COIL. DEMO REFER LINES AND CD TO STUB OUTS. EXISTINGISUPPLY AIR DUCT OUT\ TO SPACE EXISTING CD. LINE TO APPROVED LOCATION EXISTING REFRIGERANT LINES UP TO ROOF CONNECT FA COIL TO EXISTING SUPPLY AIR DUCT NEW EXISTINGSUPPLY AIR DUCT OUT TO;SPACE REVIEWED FOR DE COMPLIANCE APPROVED JUN 112018 A06/01/18 PERMIT SET No. Date Revisions Description Project FIRST FLOOR. HVAC DEMO PLAN 1/8"=1'-0" FIRST FLOOR HVAC PLAN 1/8"=1'-0" WcA 6300 SOUTHCENTER BLVD. BLDG. UNIT REPLACEMENT 6300 SOUTHCENTER BLVD. TUKWILA, WA 98188 RECEIVED CITY OF TUKWILA JUN 01 2018 PERMIT CENTER Title FIRST FLOOR HVAC DEMO PLAN & HVAC PLAN PERMIT SET DATE: 06/01/2018 T.TOUTONGHI Designed By T.TOUTONGHI Drawn By 1898866 S.CAMIS Checked By D.DALLUM Project Manager Job Number AS SHOWN Scale 6/1/2018 Print Date 5300 DENVER AVE. S SEATTLE, WA 98108 (206) 787-8500 THE PLANS AND SPECIFICATIONS HEREIN ARE OWNED BY AND FOR THE SOLE USE OF ACCO ENGINEERED SYSTEMS, INC ('ACCO'), AND MAY NOT BE REPRODUCED OR USED BY OTHERS FOR ANY PURPOSE UNLESS AUTHOR/ZED BY ACCO IN WRITING. ACCO CANNOT ACCEPT ANY LIABILITY, WARRANTY, OR OBLIGATION IN THE EVENT OF UNAUTHORIZED USE. LEVEL 2 AREA OF WORK KEY PLAN EXISTIAA��G CD. LNE TO IY ... APPROVED LOCATION EXISTING ;REFRIGERANT LINES I UP-TO ROOF DEMO EXISTING FAN COIL. DEMO REFER LINES AND CD TO STUB OUTS. i.i EXISTING CD LI \1E TO APPROVED LOATION EXISTING REFRIGERANT LINES UP` TO ROOF CONNECT NEW FM COIL. TO CD. AND REFER --LINE STUBOUT,S CONNECT FAN COIL TO EXISTING SUPPLY AIR DUCT EXISTING1 SUPPLY. AIR DUCT ?, OUT_.TO_`SP ACE JUN 11 2018 A06/01/18 No. Date Revisions Project PERMIT SET TT Description By 2ND FLOOR HVAC DEMO PLAN 1/8"=1'70" 2ND FLOOR HVAC PLAN 6300 SOUTHCENTER BLVD.. BLDG. UNIT REPLACEMENT RECEIVED CITY OF TUKWILA JUN 01 2018 PERMIT CENTER 6300 SOUTHCENTER BLVD. TUKWILA, WA 98188 2ND FLOOR HVAC DEMO PLAN & HVAC PLAN DATE: 06/01/2018 T.TOUTONGHI Designed By T.TOUTONGHI Drawn By 1898866 S.CAMIS Checked By D.DALLUM Project Manager Job Number AS SHOWN Scale 6/1/2018 Print Date DEMO EXISTING CONDENSING UNIT. DEMO REFER LINES TO STUB OUTS. EXISTING REFER LINES DOWN TO LEVEL 1 5300 DENVER AVE. S SEATTLE, WA 98108 (206) 787-8500 THE PLANS AND SPECIFICATIONS HEREIN ARE OWNED BY AND FOR THE SOLE USE OF ACCO ENGINEERED SYSTEMS, INC ('ACCO'), AND MAY NOT BE REPRODUCED OR USED BY OTHERS FOR ANY PURPOSE UNLESS AUTHORIZED BY ACCO IN WRITING. ACCO CANNOT ACCEPT ANY LIAR/L/TY, WARRANTY, OR OBLIGATION IN THE EVENT OF UNAUTHORIZED USE. DEMO EXISTING CONDENSING UNIT. DEMO REFER LINES TO STUB OUTS. ROOF HVAC DEMO PLAN 1/8"=1'-0" SECURE NEW CONDENSING UNIT TO NEW SLEEPERS. SLEEPERS BY OTHERS. EXISTING REFER LINES DOWN TO LEVEL 1 EXISTING REFER LINES DOWN TO LEVEL 2 A 06/01/18 No. Date Revisions SECURE NEW CONDENSING UNIT TO NEW SLEEPERS. SLEEPERS BY OTHERS./'A\ NEW Project RECEIVED CITY OF TUKWILA JUN 01 2018 PERMIT CENTER 6300 SOUTHCENTER BLVD. BLDG. UNIT REPLACEMENT 6300 SOUTHCENTER BLVD. TUKWILA, WA 98188 Title ROOF HVAC DEMO PLAN & ROOF HVAC PLAN ROOF HVAC PLAN 1/8"=1-0" DATE: 06/01/2018 T.TOUTONGHI Designed By T.TOUTONGHI Drawn By 1898866 S.CAMIS Checked By D.DALLUM Project Manager Job Number AS SHOWN Scale 6/1/2018 Print Date