Permit M18-0072 - IMPACT PUBLIC SCHOOL - VRF SYSTEM AND VAV SYSTEM
IMPACT PUBLIC SCHOOL 3438 S 148T" ST M18-0072 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 0040001025 Permit Number: M18-0072 3438 S 148TH ST Project Name: IMPACT PUBLIC SCHOOL Issue Date: 6/27/2018 Permit Expires On: 12/24/2018 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: SOKA GAKKAI INTERNATIONAL 3438 S 148TH , SEATTLE, WA, 98168 BRYAN GALVIN 4102 B PL NW , AUBURN, WA, 98001 UNIVERSAL REFRIGERATION INC (CONST) PO BOX 614, AUBURN, WA, 98071- 0614 UNIVERI159RF Phone: (253) 939-5501 Phone: (253) 939-5501 Expiration Date: 4/1/2020 DESCRIPTION OF WORK: PROVIDE NEW VRF SYSTEM WITH SEPARATE DEDICATED OUTSIDE AIR SYSTEM WITH HEAT RECOVERY TO SERVE NEW CLASSROOM SPACES. MODIFYING EXISTING VAV SYSTEM AT ADMIN AREA. Valuation of Work: $190,000.00 Type of Work: REPLACEMENT Fuel type: ELECT Fees Collected: $2,450.41 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: 125 Sewer District: VALLEY VIEW Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Date:(Q� )-7--1 t7 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development it and agr e-te,the conditions attached to this permit. Signature: Print Narna Date:6 Z7 — 20/5 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: Readily accessible access to roof mounted equipment is required. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: ***MECHANICAL PERMIT CONDITIONS*** 10: All mechanical work shall be inspected and approved under Permit Center (206/431-3670). 11: Manufacturers installation instructions shall be available on PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 0703 1800 0609 0705 0701 MECH EQUIP EFF MECHANICAL FINAL PIPE/DUCT INSULATION REFRIGERATION EQUIP ROUGH -IN MECHANICAL a separate permit issued by the City of Tukwila the job site at the time of inspection. r CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. Project No. Date Application Accepted: Date Application Expires: 10(bM (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address: 3438 S 148th St., Tukwila, WA 98168 Tenant Name: Impact Public School PROPERTY OWNER Name: Washington Charter School Development Address: 210 S Hudson St City: Seattle State: WA Zip: 98134 CONTACT PERSON — person receiving all project communication Name: BRYAN GALVIN Address: 4102 B. PL. NW. City: AUBURN State: WA Zip: Phone: (253) 939-5501 Fax: Email: BRYANG@UNIVERSALREFRIG.COM King Co Assessor's Tax No.: 0040001025 Suite Number: N/A Floor: 1 New Tenant: m Yes ❑ ..No MECHANICAL CONTRACTOR INFORMATION Company Name: UNIVERSAL REFRIGERATION Address: 4102 B. PL. NW. City: AUBURN State: WA Zip: 98001 Phone:(253) 939-5501 Fax: Contr Reg No.: UN vER1159RF Exp Date: 04/01/2020 Tukwila Business License No.: 0993124 Valuation of project (contractor's bid price): $ 1C10, USG Describe the scope of work in detail: Provide new VRF system with separate dedicated outside air system with heat recovery to serve new classroom spaces. Modifying existing VAV system at Admin area. Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement Fuel Type: Electric VI Gas Other: H:\Applications\Forms-Applications On Line \2016 Applications'Mechanical Permit Application Revised 1-4-16.docx Revised: January 2016 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type . Qty Furnace <100k btu Residential, Nighttime Furnace >100k btu 60 Floor furnace 10 Suspended/wall/floor mounted heater 57 dB(A) Appliance vent 10 Repair or addition to heat/refrig/cooling system 1 Air handling unit <10,000 cfm 10 Unit Type Qty Air handling unit Residential, Nighttime >10,000 cfm 60 Evaporator cooler 10 Ventilation fan connected to single duct 57 dB(A) Ventilation system 10 Hood and duct 1 Incinerator — domestic 65 dB(A) Incinerator — comm/industrial 60 dB(A) Unit Type Qty Fire damper Residential, Nighttime Diffuser 60 Thermostat 10 Wood/gas stove 57 dB(A) Emergency generator Commercial Other mechanical equipment 1 60 dB(A) 65 dB(A) Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-1 OPM, Monday through Friday and 8AM-10PM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: • Warning devices; • Construction and property maintenance during the daytime hours (7am-1 Opm); • Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. i BUILDING OWNER OR AUTH RIZED AGENT;? Signature: Date: 05/16/2018 Print Name: AIDAN WILSON Day Telephone: (253) 939-5501 Mailing Address: 4102 B. PL. NW. AUBURN WA 98001 CityState Zip H:\Applications\Forms-Applications On Line\2016 Applications\Mechanical Permit Application Revised 1-4-16.docx Revised: January 2016 bh Page 2 of 2 ash Register Recei City of Tukwila Receip Number,, Rf 699 3905 DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY a. PAID $2,450.41 M18-0072 Address: 3438 S 148TH ST Apn: 0040001025 a $2,450.41 MECHANICAL $2,356.16 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $1,851.78 PLAN CHECK FEE R000.322.102.00.00 0.00 $471.23 TECHNOLOGY FEE Y $94.25 TECHNOLOGY FEE R000.322.900.04.00 0.00 $94.25 TOTAL FEES PAID BY RECEIPT: R14699 $2,450.41 Date Paid: Tuesday, June 12, 2018 Paid By: UNIVERSAL REFRIGERATION Pay Method: CHECK 53406 Printed: Tuesday, lune 12, 2018 9:48 AM 1 of 1 SYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION /11 %8=6072 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Project: /mrn /aBVe Sefee Type of Inspection: ,4 ce/f/9 ieni.- FflA-L Address: Date Called: Special Instructions: Date Wanted: a.m. p.m. Requester Y Phone No: 26-3 --38:0-g8'32 Approved per applicable codes. Corrections required prior to approval. COMMENTS: 61-4- -Tx)* - M ,11v, fiN/1-L_. Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: a /D INSPECTION RECORD Retain a copy with permit INSP CTION N0. P1/416-0072 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: /1/1 PST pderie ../ L Type of Inspection: PiP0 vc r hies0-4- 7 A' Address: 1,c38S,/518Tlfc r. Date Called: Special Instructions: Date Wanted: a.m. a-10,6 p.m. Requester: _ _ r - 7tif� ' R.08F/ •'i Phone No: 2‘).(Q-5-1-0 - I (2 Or Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: ©f C- /4a/G% /# /14,tel,Od/e1.1-( (AieLooM6-- Reinms' 103 112 /0/8 /of,4 044- boar it/sew-4770A, Inspector: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 M6$ -00 77 Project:, �hIk4s Typ of Insp ction:�o� X) I Aat drets�j:csy_ 3//58' el. He' ". Date Call d: Special Instructions: " Date Wanted:' yr zd`j p m. Requester: Phone No: Approved per applicable codes. J Corrections required prior to approval. COMMENTS: 7-4 /eked) Ay -41 4U L raecos O/C � C.Lc cr1.Ifoc, A1_5 I 0 3 (d /17 Inspector: (12P Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. l OO7Z INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: b�ICJSL�7t.1815 T e of Inspection: • Add 3143RS 1y ` V-, .., Special Instructions: *C t C,c pe4' � Date Wanted:,�I� S -3' �=�t a.m p.m. RequGr;,ter oerAw Phone No: _ (zoZ -i 110 0& Approved per applicable codes. Corrections required prior to approval. COMMENTS: /_ Qoo" 106)— 10 nom/ ef-/44JICA — ZIP iNSOLA-fl Inspector: ref Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Mt$- 00-12 Project: /44/397 s5'&fi'OL Type of Inspection: itou64.4 /1V rmEC1owi(A-i- t4N4f OP /we D )c1 fw" o0i310dL 76 Address: 3958 S, /08 Sr; Date Called: - Special Instructions: Date Wanted:a.m. 7-218 • Requester: Phone No: 20Co— 570 -/I@Od ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: �% t4N4f OP /we D )c1 fw" o0i310dL 76 Oohs /14 aACW cUts's t^'‘ cmj L?/ o k — OM /A -7--g Inspector: Date: 1-2.7-(8 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: 7-"3 /8 1 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: /IMP T PV5ue V0450/.... Type of Inspection: Address: 308s./8 •5'7r, Date Called: Special Instructions: fr-17,v/%r Date Wanted: -7-/3-la p.m. Requester: Phone No: Approved per applicable codes. J Corrections required prior to approval. COMMENTS: ok— /907)4111\1G- dI' C'vR8 fMR Rif P kV/ s � N -t -o) 1_.e crn7,J✓ - iixireA 1)47711L, Inspector: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. UNIVERSAL REFRIGERATION HEATING & AIR COMITIOHING Heating Air Conditioning Refrigeration Contractors Lic# UNIVERI.159RF Oregon Lic# 160248 L._ _ Impact Public School Tukwila, WA HVAC Equipment Submittals From: Universal Refrigeration, Inc Bryan Galvin REVIEWED FOR CODE COMPLIANCE APPROVED JUN 21 2018 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA 322u3 PERMIT CENTER iAfte0011.-. P.O. Box 614 • 4102 "B" PL NW • Auburn, WA 98071 Seattle: (253) 839-2126 • Tacoma: (253) 922-3141 • Auburn: (253) 939-5501 • Fax: (253) 735-3432 Table of Contents 1. LG heat pump, LG fan coils, and Aides energy recovery ventilators 2. Grilles, diffusers, and louvers Section #1 LG heat pump LG fan coils Aldes energy recovery ventilators LG Electronics Model Selection - Analysis Project Name :Impact 1-19-18 TH Total Price 0 1. Outdoor Units MULTI V ver 1.5.0.1 01/19/2018 Model Name Quantity Unit Price Total Price ARUM408DTE5 1 0 Total 1 0 2. Indoor Units Model Name Quantity Unit Price Total Price ARNU483BRA4 10 0 Total 10 0 3. Branch/Header/Common pipe Model Name Quantity Unit Price Total Price ARBLB07121 1 0 ARBLB14521 1 0 ARCNB21 1 0 PRHR022A 1 0 PRHR042A 2 0 Total 6 0 4. Pipes Dia(inch) Length(ft) Unit Price Total Price 1+1/8 9 0 1+3/8 32 0 1+5/8 30 0 3/8 315 0 3/4 72 0 5/8 282 0 7/8 47 0 Total 787 0 LG Electronics Model Selection - Tree - CU -1 MULTI V ver 1.5.0.1 Project Name :Impact 1-19-18 TH 01/19/2018 System No :1/1 1 1 0 • 0 0 0 TTTT 0 0 0 0 0 0 0 0 1 IY 1 rg I ye I • t X N 0 • 0 0 O 0 0 0 0 0 0 0 1 C I T co T reo IXo CCo reo 59 et et to e Lei .aiet et to . $ v v `O 00 0 m IHI 66 O vi LG Electronics Model Selection - Diagram - CU -1 MULTI V ver 1.5.0.1 Project Name :Impact 1-19-18 TH 01/19/2018 System No :1/1 ARUM408DTE5 CombL:ARUM192DTE5,ARUM216DTE5 Additional refrigerant : 36.42 bs I Communication Lhe MCA : 74.0 MOP : 100 V,H2 : 3/460V/60Hz PRHR042A RLA : 0.16 ARNU483BRA4 1.1 ARNU483BRA4 ARNU483BRA4 ARNU483BRA4 PRHR042A RLA : 0.16 ARNU483BRA4 ARNU483BRA4 ARNU483BRA4 1. ARNU483BRA4 11 PRHR022A RLA : 0.08 ARNU483BRA4 ARNU483BRA4 Total RLA : 23.40 # Note : Power wiring, breaker size, and disconnects shall follow local code or NEC Multi-frame outdoor unit models require a separate power connection for each frame. Refer to the most current submittal sheets for applicable electrical data. RLA :: 2.30 RLA : 2.30 RLA : 2.30 RLA : 2.30 RLA : 2.30 RLA : 2.30 RLA : 2.30 RLA : 2.30 RLA : 2.30 RLA : 2.30 LG Electronics Oil Trap Requirement Project Name :Impact 1-19-18 TH Dual Frame - Horizontal To IDUs 1 HRUs Triple Frame - Horizontal Oil trap required: To IDUs I HRUs • MULTI V ver 1.5.0.1 01/19/2018 Duel Frame - Overhead 'must be taped when Installed overhead Triple Frame - Overhead - Overhead piping - Horizontal piping when distance between frame and connecting Y -branch exceeds 6.6 feet - High Vapor and Low Vapor pipes only - Oil trap must be minimum 8" high and wide - Oil trap must be located close to connecting Y -branch (no farther than 6.6 feet) Connecting Y -branches must be horizontal Job Name/Location: Date: PO No.: Architect: For: ❑ File ❑ Resubmit ❑ Approval ❑ Other GC: Engr: Mech: Tag #: HP -1 Rep: (Company) (Project Manager) ARUM408DTE5 (a) ARUM192DTE5 Multi VT"' 5 Dual Frame 460V (b) ARUM216DTE5 34.0 Ton Outdoor Unit for Heat Pump and Heat Recovery Performance: Cooling Mode: Nominal Capacity (Btu/h) Power Input' (kW) 408,000 28.98 Heating Mode: Nominal Capacity (Btu/h) Power Input' (kW) 459,000 33.21 Nominal Capacity is outside the scope of AHRI Standard 1230 and based on the following conditions: Indoor: 70°F DB Outdoor 47°F DB / 43°F WB Indoor: 80°F DB / 67°F WB Outdoor 95°F DB Electrical: Power Supply (V/Hz/0) MOP (A) MCA (A) Rated Amps (A) Compressor A (A) Compressor B (A) Fan (A) Piping: (a) ARUM192DTE5 (b) ARUM216DTE5 460/60/3 50 35.7 32.0 14.8 12.2 5.0 460/60/3 50 38.3 34.4 15.5 13.9 5.0 (a) ARUM1.92DTE5 (b) ARUM216DTE5 Refrigerant Charge (lbs) Liquid Line2 (in, OD) Vapor Line Hight (in, OD) Heat Recovery Only Vapor Line Low2 (in, OD) 30.9 5/8 Braze 1-1/8 Braze 37.5 5/8 Braze 1-1/8 Braze 1-1/8 Braze 1-1/8 Braze Standard Features: •Advanced Smart Load Control •Intelligent Heating •HiPOR (high pressure oil return) •Smart Oil Control •Night Quiet Operation Required Accessories: • ARCNB21 (frame connector Y -branch) •Fault Detection and Diagnosis •Active Refrigerant Control •Variable Path Heat Exchanger •Subcooling and Vapor Injection Control •Liquid Cooled Inverter Controller Optional Accessories: ❑ Air Guide - ZAGDKA52A (2 required) • Hail Guard Kit - ZHGDKA52A (2 Required) ❑ Low Ambient Baffle Kit - ZLABKA52A (2), Control Kit - PRVC2 (1 per system) LG Life's Good ®LG Operating Range: 016 Cooling (°F DB)** Heating (°F WB) Synchronous Cooling Based (°F DB) Heating Based (°F WB) 5-122 -13 - 61 14 — 81 14 — 61 Unit Data: Refrigerant Type Refrigerant Control Max Number of Indoor Units' Sound Pressure` dB(A) Net Unit Weight (a) + (b) (lbs) Shipping Weight (a) + (b) (lbs) Communication Cables (No x AWG) Heat Exchanger Coating R410A EEV 64 66.0 659+666 688+694 2 x 18 Black Coated Fins" Compressor: Type Quantity Oil/Type Fan: HSS DC Scroll 4 PVE/FVC68D Type Quantity Motor/Drive Air Flow Rate (CFM) Propeller 4 Brushless Digitally Controlled/Direct 22,600 Notes: 1.For AHRI ratings, refer to the AHRI website http://www.ahrldlrectory.org. 2.For main pipe segment size, refer to the LATS Multi V free diagram. 3.The combination ratio must be between 50-130%. 4.Sound Pressure levels are tested in an anechoic chamber under ISO Standard 3745 for the combination of outdoor units. 5.AII communication cable to be minimum 18 American wire gage (AWG), 2 -conductor, stranded, shielded or unshielded wire and must comply with applicable local and national code. If shielded, the wire must be grounded to the chassis at the outdoor unit only. 6.Nominal data is rated 0 ft above sea level, with 25 ft of refrigerant line per indoor unit and a 0 ft level difference between outdoor and indoor units. All capacities are net with a combination ratio between 95-105%. 7.Power wiring cable size must comply with the applicable local and national code. Cables terminate at each frarne. 8.The voltage tolerance is 414-528V. 9.The order of each of these units on the submittal (i. e.,A4-13) do not represent the installation order. Highest capacity unit is used as the Master, followed by the next smaller size as Slave 1 and so on. Inverter Os Intertek **(-9.9°F achieved only when all IDU's are operating in cooling mode. Does not impact synchronous operating range.) LG Electronics USA, Inc. 1000 Sylvan Ave, Englewood Cliffs, NJ 07632/www.lg-vrf.com © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG Life's Good" is a registered trademark of LG Corp. /www.Ighvac.com yaratiaRetnpurtFklw(vRF)M lu-SpalACn+tdHP 41)))(Standga12-1O .;' SB_MultiV_5_DDU_ARUM408DTE5_01_17 Page 1 of 2 Job Name/Location: ARUM408DTE5 (a) ARUM192DTE5 Multi VT" 5 Dual Frame 460V (b) ARUM216DTE5 34.0 Ton Outdoor Unit for Heat Pump and Heat Recovery O --E> Airflow bAirflow 1i! 11111111111 i! IliiIil lird1IIIIIIIIIIII IIIi !1I' 1 iii'!!!'./:IIIIIIi' P:filliIIIII!•:I!iIIIIII" 11111111,1113,11111111! 111111111111;11, 1111111! iIIIIII nIlril''Illl',I,Il'IIIII!inunl' 1'II'i' !III I:SIIIIIIIII!,I!11!I:!II:II!IIIIIIIID! !i r;fiiilll111Ui11!4111111!:1iVoilu0,j: I Airflow Top View 718' Diameter Leak Test Hole Left Side View M5 L10 Airflow Power Cord Routing Hole (Bottom); two (2) - 02" front View -3/16 Diameter wiring k ockout 1-25/32" Diameter wiring knockout Two (2) 7/8" Diameter Wire Routing Holes (Bottom) 19/32" Diameter hole M Piping Routing Holes (Bottom); two - e2-5/8° 02-1/8" (Pitch of foundation bolt holes) Bottom Mounting Holes LG Electronics USA, Inc. 1000 Sylvan Ave, Englewood Cliffs, NJ 07632/www.lg-vrf.com (Pitch of foundation bolt Tag #: HP -1 LG Date: Life's Good PO No.: Multi -Frame Configurations Please refer to multi-frame placement information and piping rules in the Multi V 5 Engineering Manual and the Multi V 5 Installation Manual. 1 .r MMIN y 4 Airflow L5 L6 L7 Right Side View M1 28-25/32" M2 5/8" M3 3-15/16" M4 40-15/16" M5 11-15/16" M6 11-1/16" M7 10-1/2" M8 8 - 7/16" M9 8-1/8" M10 6 -1/16" M11 4- 15/16" M12 7-1/2" M13 4 -13/16" M14 4- 5/16" M15 3 - 5/8" M16 3" © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG Life's Good" is a registered trademark of LG Corp. /www.lghvac.com L8 W 48-13/16" H 66-17/32" D 29-29/32" L1 6-5/16" L2 3-3/4" L3 5-29/32" L4 5-13/32" L5 2-25/32" L6 24-9/32" L7 2-25/32" L8 4-1/32" L9 6 -1/2" L10 5-9/16" L11 8- 5/8" L12 6 - 7/16" L13 9 -15/16" L14 3 - 5/8" Center of Gravity X 23-7/32" Y 15-5/8" Z 25-9/16" All dimensions have a tolerance of ± 0.25 in. [Unit: inch] = Center of Gravity SB_MultiV_5_ODU_ARUM408DTE5_01_17 Page 2 of 2 Job Name/Location: Date: PO No.: Architect: For: ❑ File ❑ Resubmit El Approval ❑ Other GC: Engr: Mech: Rep: (Company) (Project Manager) ARUM408BTE5 (a) ARUM192BTE5 Multi VTM 5 Dual Frame 208-230V (b) ARUM216BTE5 34.0 Ton Outdoor Unit for Heat Pump and Heat Recovery Performance: Cooling Mode: Nominal Capacity (Btu/h) Power Input' (kW) 408,000 28.98 Heating Mode: Nominal Capacity (Btu/h) Power Input' (kW) 459,000 33.21 Nominal Capacity is outside the scope of AHRI Standard 1230 and based on the following conditions: Indoor: 80°F DB / 67°F WB Indoor: 70°F DB Outdoor 95°F DB Outdoor 47'F D8 / 43°F WB Electrical: (a) ARUM192BTE5 (b) ARUM216BTE5 Power Supply (V/Hz/0) MOP (A) MCA (A) Rated Amps (A) Compressor A (A) Compressor B (A) Fan (A) 208-230/60/3 208-230/60/3 80 80 57.9 60.3 52.1 54.2 23.3 24.3 20.8 21.9 8.0 8.0 Piping: (a) ARUM192BTE5 (b) ARUM216BTE5 Refrigerant Charge (lbs) Liquid Line2 (in, OD) Vapor Line High' (in, OD) Heat Recovery Only Vapor Line Low2 (in, OD) 30.9 5/8 Braze 1-1/8 Braze 37.5 5/8 Braze 1-1/8 Braze 1-1/8 Braze 1-1/8 Braze Standard Features: •Advanced Smart Load Control •Intelligent Heating •HiPOR (high pressure oil return) •Smart Oil Control •Night Quiet Operation Required Accessories: ❑ ARCNB21 (frame connector Y -branch) •Fault Detection and Diagnosis •Active Refrigerant Control •Variable Path Heat Exchanger •Subcooling and Vapor Injection Control •Liquid Cooled Inverter Controller Optional Accessories: ❑ Air Guide - ZAGDKA52A (2 required) ❑ Hail Guard Kit - ZHGDKA52A (2 Required) ❑ Low Ambient Baffle Kit - ZLABKA52A (2), Control Kit - PRVC2 (1 per system) Tag #: HP -1 LG Life's Good E cc Operating Range: Cooling (°F DB)** Heating (°F WB) Synchronous: Cooling Based (°F DB) Heating Based (°F WB) 5-122 -13 - 61 14-81 14 — 61 Unit Data: Refrigerant Type Refrigerant Control Max Number of Indoor Units' Sound Pressure" dB(A) Net Unit Weight (a) + (b) (lbs) Shipping Weight (a) + (b) (lbs) Communication Cables (No x AWG) Heat Exchanger Coating R410A EEV 64 66.0 659+666 688+694 2 x 18 Black Coated Fina Compressor: Type Quantity Oil/Type Fan: HSS DC Scroll 4 PVE/FVC68D Type Quantity Motor/Drive Air Flow Rate (CFM) Propeller 4 Brushless Digitally Controlled/Direct 22,600 Notes: 1.For AHRI ratings, refer to the AHRI website http://www.ahridirectory.org. 2.For main pipe segment size, refer to the LATS Multi V tree diagram. 3.The combination ratio must be between 50-130%. 4.Sound Pressure levels are tested in an anechoic chamber under ISO Standard 3745 for the combination of outdoor units. 5All communication cable to be minimum 18 American wire gage (AWG), 2 -conductor, stranded, shielded or unshielded wire and must comply with applicable local and national code. If shielded, the wire must be grounded to the chassis at the outdoor unit only. 6.Nominal data is rated 0 ft above sea level, with 25 ft of refrigerant line per indoor unit and a 0 ft level difference between outdoor and indoor units. All capacities are net with a combination ratio between 95-10S%. 7.Power wiring cable size must comply with the applicable local and national code. Cables terminate at each frame. 8. The voltage tolerance Is 187 - 253V. 9.The order of each of these units on the submittal (i.e., A+B) do not represent the installation order. Highest capacity unit is used as the Master, followed by the next smaller size as Slave 1 and so on. Inverter Ll **(-9.9°F achieved only when all VDU's are operating in cooling mode. Does not impact synchronous operating range.) LG Electronics USA, Inc. 1000 Sylvan Ave, Englewood Cliffs, NJ 07632/www.ig-vrf.com © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG Life's Good" is a registered trademark of LG Corp. /www.lghvac.com cus Intertek ViialkfletrtrolRow (VROMiIM-SPN math MRISt sdagd 1230 SB_MultiV_5_ODU_ARUM408BTE5_01_17 Page 1 of 2 Airflow 0,1111111111111 IIGlII Ii!i111111IIIIIlI11111 i; 1 di'!!!!.1111IIIIiI1' iillii:;!!!!!.11i11111 +' IIIIIIII,11;1011IIIIn•I IIIIIIIII!I;li;.11111111 t1IIIIPii ilii:l'I11I'.,111:1IIII!iiioiiii°iI!!?i !III';::IIIIIIIII!,I!I V01'11 1111111111! !i 6,'v'tiinto"'ii1!flilUNl:!4r •Jlulii! _ Job Name/Location: ARUM408BTE5 (a) ARUM192BTE5 Multi VT" 5 Dual Frame 208-230V (b) ARUM216BTE5 34.0 Ton Outdoor Unit for Heat Pump and Heat Recovery Airflow Airflow Top View 718" Diameter Leak Test Hole Left Side View M5 L10 Airflow Front View 1-3/16 Diameter wiring k ockout 1-25/32" Diameter wiring knockout Power Cord Routing Hole Two (2) 7/8" Diameter Wire (Bottom); two (2) - 02" Routing Holes (Bottom) Piping Routing Holes (Bottom); two - e2-518," 02-1/8" (Pitch of foundation bolt holes) Bottom Mounting Holes 19/32" Diameter hole co 0 0 0 0 0 Tag #: HP -1 LGDate: Life's Good PO No.: Multi -Frame Configurations Please refer to multi-frame placement information and piping rules in the Multi V 5 Engineering Manual and the Multi V 5 Installation Manual. ;11)111111III I. Airflow ua L5 L6 Right Side View M1 28-25/32" M2 5/8" M3 3-15/16" M4 40-15/16" M5 11-15/16" M6 11 - 1/16" M7 10-1/2" M8 8- 7/16" M9 8-1/8" M10 6 -1/16" M11 4- 15/16" M12 7-1/2" M13 4-13/16" M14 4-5/16" M15 3-5/8" M16 3" LG Electronics USA, Inc. 1000 Sylvan Ave, Englewood Cliffs, N1 07632/www.lg-vrf.com ® LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG Life's Good" is a registered trademark of LG Corp. /www.Ighvac.com L7 L8 W 48-13/16" H 66-17/32" D 29-29/32" L1 6-5/16" L2 3-3/4" L3 5-29/32" L4 5-13/32" L5 2-25/32" L6 24-9/32" L7 2-25/32" L8 4-1/32" L9 6-1/2" L10 5 - 9/16" L11 8 - 5/8" L12 6 - 7/16" L13 9-15/16" L14 3 - 5/8" Center of Gravity X 1 23-7/32" Y 15-5/8" Z 25-9/16" All dimensions have a tolerance of ± 0.25 in. [Unit: inch] = Center of Gravity SB_MultiV_S_ODU_ARUM4088TES_01_17 Page 2 of 2 Job Name/Location: Date: PO No.: Architect: For: ❑ File ❑ Resubmit ❑ Approval ❑ Other GC: Engr: Mech: Rep: (Company) (Project Manager) ARNU483BRA4 Multi VTM Ducted (High Static) 48,100 Btu/h Indoor Unit Performance: Total Cooling Capacity (Btu/h) Heating Capacity (Btu/h) Power Input' (W) 48,100 51,200 450 Cooling Nominal Test Conditions: Indoor: 80°F DB/67°F WB Outdoor 95°F DB Electrical: Heating Nominal Test Conditions: Indoor: 70°F DB Outdoor 47°F DB/43°F WB Power Supply (V/Hz/0) Rated Amps (A) 208-230/60/1 2.76 Piping: Refrigerant: Liquid Line (in, OD) Vapor Line (in, OD) 3/8 Flare 5/8 Flare Condensate: Condensate Pump Drain' (in,OD) Gravity Drain Plugged (in, OD) 1 Plain 1 MPT Controls Features: •Auto changeover (Heat Recovery only) •Auto operation •Auto restart •Dual thermistor control •Dual setpoint control •Multiple aux heater applications •Filter life and power consumption display Optional Accessories: ❑ Wireless Remote Controller' - PQWRHQOFDB ❑ LG Programmable Controller - PREMTB1OU ❑ LG Premium Controller- PREMTA000 • Simple Controller with Mode (Black) - PQRCVCLOQ ❑ Simple Controller with Mode (White) - PQRCVCLOQW ❑ Simple Controller without Mode (Black) PQRCHCAOQ ❑ Simple Controller without Mode (White) - PQRCHCAOQW ❑ Simple Dry Contact (1 contact, 24 VAC external power) - PQDSB1 • Dry Contact for Economizer - PQDSBC1 ❑ Dry Contact for Third Party Thermostat - PQDSBNGCM1 ❑ Wall Mounted Temperature Sensor - PQRSTAO ❑ High Efficiency Filter Box for BR HSD Chassis - ZFBXBRO1A ❑ Dynamic V8 2VL Low Profile Air Cleaner - ZPLMV201A Cl Dynamic V8 4VL Air Cleaner - ZPLMV402A ❑ Dynamic V8 VL Replacement Filter Pads (4 -Pack) - ZFLT1301A ❑ Dynamic V8 VL Replacement Filter Pads (24 Pack) - ZFLT1302A ❑ Return Air Grille - Louvered (one per plenum) - ZGRLRAO1A ❑ Return Air Grille - Egg Crate (one per plenum) - ZGRLRAO2A ❑ 2VL Low Profile Return Air Plenum - ZPLMV201A ❑ 4VL Return Air Plenum - ZPLMV402A •Weekly schedule •Fan speed control •Group control •Hot start *Self diagnostics •Timer (on/off) •Child lock L life's Good Tag #: FCU -1 through FCU -10 Entering Mixed Air: Cooling Max` (°F WB) Heating Min (°F DB) 76 59 Unit Data: Refrigerant Type Refrigerant Control Sound Pressures dB(A) (H/M/L) Filter Type MERV Filter Quantity Filter Dimensions' Net Unit Weight (lbs) Shipping Weight (lbs) R410A EEV 45/43/41 Washable N/A 1 7-1/2" x 30-3/4" x 1/4" 112 132 Fan: Type Fan Quantity Motor/Drive Motor Quantity Sirocco 2 Brushless Digitally Controlled/Direct 2 Standard Mode Airflow Rate H/M/L (CFM) 1,568/1,395/1,183 Standard Mode External Static Pressure (ESP)7(in wg) 0.39 High Mode Airflow Rate H/M/L (CFM) 1,582/1,434/1,176 High Mode External Static Pressure (ESP)7(in wg) 0.55 Minimum ESP (in wg)" Maximum ESP (in wg)" 0.19 0.78 Notes: 1. The Power Input is rated at high speed. 2. Maximum lift is 27 in from bottom of unit. Check valve not included (field supplied). 3. Requires an 1G wall controller because ducted units do not have infrared receiver. 4. See Engineering Manual for sensible and latent capacities. 5. Sound Pressure levels are tested in an anechoic chamber under 150 Standard 3745. 6. Actual filter sizes may vary. 7. At factory fan speed setting. 8. Air flow rate (CFM) at high speed. 9. All communication cable to be minimum 18 AWG, 2 -conductor, stranded, shielded and must comply with applicable local and national code. 10. Power wiring cable size must comply with the applicable local and national code. 11. This unit comes with a dry nitrogen charge. 12. This data is rated 0 ft above sea level, with 25 ft of refrigerant line per indoor unit and a 0 ft level difference between outdoor and indoor units. All capacities are net with a combination ratio between 95 —105%. 13. Must follow installation instructions in the applicable LG Installation manual. oti«%ue Intertek For continual product development, LG reserves the right to change specifications without notice. LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG Life's Good" is a registered trademark of LG Corp. /www.Ighvac.com SB-MultiVlV_HighStaticDucted-ARNU483BRA4-01-15 Page 1 of 2 Job Name/Location: ARNU483BRA4 Multi VTM Ducted (High Static) 48,100 Btu/h Indoor Unit 43 LG Life's Good 4-3/4 Tag #: FCU -1 through FCU -10 Date: PO No.: Power Supply Connection I) • ai • 9.1/2 11 9.1/2 11 8-1/2 f` Se - 39-9/16 Liquid Pipe Connection: 3/8 Gas Pipe Connection: 5/8 3-15116 Drain Pipe Connection:1 & Center of Gravity Unit: inches Note: All measurements have a tolerance of ±1/4 in. For continual product development, LG reserves the right to change specifications without notice. LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG Life's Good" is a registered trademark of LG Corp. /www.lghvac.com SB-MultiVIV_I+ighStaticDucted-ARNU483BRA4-01-15 Page 2 of 2 Job Name/Location: Tag #: HRB-03 Date: PO No.: Architect: For: 0 File ❑ Resubmit 0 Approval ❑ Other GC: Engr: Rep: Mech: (Company) (Project Manager) PRHR022A Multi VTM Heat Recovery Unit Performance: Max Port Capacity Btu/h (each port) Max Unit Capacity Btu/h (sum of ports) Power Input (W) 54,000 192,000 26 Electrical: Power Supply (V/Hz/0) Rated Amps (A) 208-230/60/1 0.08 Piping: Refrigerant: Port Liquid Line (in, OD) Port Vapor Line (in, OD) System Liquid Line (in, OD) System Vapor Line High (in, OD) System Vapor Line Low (in, OD) 3/8 5/8 3/8 3/4 7/8 Standard Features: *Allows connected indoor units to be in cooling or heating mode simultaneously •Internal components are insulated •External casing insulation is not needed' •Condensate drain not needed •Series or parallel connection with additional heat recovery units •Flexible placement for service access or pipe routing •Access panels •Top panel for solenoid valve heads •Rear panel for control access •Bottom panel for refrigerant circuit L Life's Good Unit Data: Refrigerant Type Number of Indoor Unit Ports2 Sound Pressure Data: Cooling Mode dB(A) Heating Mode dB(A) Simultaneous dB(A) Net Unit Weight (lbs) Shipping Weight (lbs) R410A 2 35.2 35.1 43.3 40 48 Notes: 1AII refrigerant pipes require insulation. 2.Each port can allow up to 8 indoor units with a maximum capacity of 48 MBh per port. 3AII communication cable to be minimum 18 AWG, 2 -conductor, stranded, shielded and must comply with applicable local and national code. 4.Kit components must be kept dry and free of debris before installation. S.Must follow installation instructions in the applicable LG installation manual. 6.Power wiring cable size must comply with the applicable local and national code. 7.This unit comes with a dry nitrogen charge. ®"• Intertek For continual product development, LG reserves the right to change specifications without notice. LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG Life's Good" is a registered trademark of LG Corp. /www.lghvac.com SR-MuItiVIV_HeatRecovery-PRHR022A-01-15 Page 1 of 2 Job Name/Location: PRHR022A Multi VTM Heat Recovery Unit M4 Control Access Panel Wiring Openings N System Piping Port Piping System Piping Y2"Diameter opening L Tag #: HRB-03 Date: Life's Good p0 No.: Vapor line low Vapor fine high Liquid line W 17-7/8" H 8-5/8" D 18-15/16" L1 6-7/8" L2 6-5/8" L3 11-3/8" L4 6-7/8" L5 3-1/2" L6 5-1/2" L7 1-3/16" L8 3-9/16" L9 5-7/16" L10 4-3/4" L11 5-3/4" L12 7-1/4" L13 1-1/4" M1 3-3/4" M2 13-5/8" M3 1-1/2" M4 18-15/16" Reducer Dimensions (in) 1 2 3 Quantity Indoor Unit Liquid Line 3/8 OD 1/4 OD - 2 Vapor Line 5/8 OD 1/2 OD - 2 HR Unit Liquid Line 3/8 OD 1/4 OD - 2 Vapor Line Low 5/8 OD 1/2 OD - 2 7/8 00 3/4 OD 5/8 OD 2 Vapor Line High 1/2 OD 3/8 OD 2 3/4 OD 5/8 OD 1/2 OD 2 For continual product development, LO reserves the right to change specifications without notice. LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG Life's Good" is a registered trademark of LG Corp. /www.lghvac.com SE-MuItiVIV_HeatRecovery-PRHR022A-01-15 Page 2 of 2 Job Name/Location: Date: PO No.: Architect: For: ❑ File 0 Resubmit El Approval El Other GC: Engr: Rep: Tag #: HRB-01 and HRB-02 (Company) (Project Manager) PRH R042A Multi VT" Heat Recovery Unit Performance: Max Port Capacity Btu/h (each port) Max Unit Capacity Btu/h (sum of ports) Power Input (W) 54,000 192,000 40 Electrical: Power Supply (V/Hz/0) Rated Amps (A) 208-230/60/1 0.16 Piping: Refrigerant: Port Liquid Line (in, OD) Port Vapor Line (in, OD) System Liquid Line (in, OD) System Vapor Line High (in, OD) System Vapor Line Low (in, OD) 3/8 5/8 5/8 7/8 1-1/8 Standard Features: •Allows connected indoor units to be in cooling or heating mode simultaneously •Internal components are insulated •External casing insulation is not needed' •Condensate drain not needed •Series or parallel connection with additional heat recovery units •Flexible placement for service access or pipe routing •Access panels • Top panel for solenoid valve heads • Rear panel for control access •Bottom panel for refrigerant circuit Unit Data: Refrigerant Type Number of Indoor Unit Ports' Sound Pressure Data: Cooling Mode dB(A) Heating Mode dB(A) Simultaneous dB(A) Net Unit Weight (lbs) Shipping Weight (lbs) R410A 4 35.2 35.1 43.3 49 57 Notes: 1.AII refrigerant pipes require insulation. 2.Each port can allow up to 8 indoor units with a maximum capacity of 48 MBh per port. 3.AII communication cable to be minimum 18 AWG, 2 -conductor, stranded, shielded and must comply with applicable local and national code. 4.Kit components must be kept dry and free of debris before installation. 5.Must follow installation instructions in the applicable LG installation manual. 6.Power wiring cable size must comply with the applicable local and national code. 7.This unit comes with a dry nitrogen charge. Os Intertek For continual product development, LG reserves the right to change specifications without notice. LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG Life's Good" is a registered trademark of LG Corp. /www.Ighvac.com SB-MuItiVIV_HeatRecovery-PRHR042A-01-1S Page 1 of 2 Job Name/Location: PRHR042A Multi VTM Heat Recovery Unit Control Access Panel Wiring Openings System 2 Piping System Piping Port Piping Tag #: HRB-01 and HRB-02 1.2 Date: Life's Good PO No.: %2"Diameter opening 7 L1— L2 L3 L4 L5 W 17-7/8" H 8-5/8" D 18-15/16" L1 6-7/8" L2 4-1/4" L3 7-1/2" L4 10-1/2" L5 13-3/4" L6 6-7/8" L7 3-1/2" L8 5-1/2" L9 1-3/16" L10 3-9/16" L11 5-7/16" L12 4-3/4" L13 5-3/4" L14 7-1/4" L15 1-1/4" M1 3-3/4" M2 13-5/8" M3 1-1/2" M4 18-15/16" Reducer Dimensions (In) 1 2 3 Quantity Indoor UnitLiquid Line 3/8 OD 1/4 OD - 4 Vapor Line 5/8 OD 1/2 OD - 4 HR Unit Liquid Line 1/2 OD 3/8 OD - 2 Vapor Line Low 3/4 OD 5/8 OD - 2 1-1/8 OD 7/8 OD 3/4 OD 2 Vapor Line High 5/8 OD 1/2 OD 2 7/8 0D 3/4 0D 5/8 0D 2 For continual product development, LG reserves the right to change specifications without notice. LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG Life's Good" is a registered trademark of LG Corp. /www.lghvac.com SB-MuItiVIV_HeatRecovery-PRHR042A-01-15 Page 2 of 2 Job Name/Location: Date: PO No.: Architect: For: ❑ File ❑ Resubmit ❑ Approval ❑ Other GC: Engr: Mech: Rep: Tag #: Room thermostats (Company) (Project Manager) PREMTBVC1 MuItiSITE CRC1+ Remote Controller Electrical: Power Supply 12VDC power from indoor unit Surrounding Conditions: Temperature Operating Storage Humidity Operating Storage 32-122 °F -22-122 °F 5-95% RH (non -condensing) 0-95% RH (non -condensing) Features: •Customizable color digital touch screen interface with Multilanguage support •BACnet® MS/TP •ZigBee Pro® Wireless network •On -board Motion (PIR) and Humidity Sensor •Role based configuration (password protected) •Function code settings •Function Code Search Tool •Date and Time Display •Room temperature display •Humidity Display •Operation - On/Off •Mode - Auto/Cool/Dry/Heat/Fan Only •Occupied cooling and heating temperature setpoints •Unoccupied cooling and heating temperature setpoints •7 day scheduling with mode •Fan speed - Auto/Low/Med/High/Power •Discharge vanes - Auto/Swing/Fixed •Static pressure installer setting •Error code display during unit or system malfunction Optional Accessories (sold separately): ❑ PZCWRCG3 - Group Control Cable Kit ❑ ZVRCZPWC1 - ZigBee Pro® Wireless Modulen ❑ ZVRCZDWS1 - Wireless Door Window Switch3 ❑ ZVRCZCOC1 - Wireless Ceiling Mounted Occupancy Sensor3 ❑ ZVRCZWOC1 - Wireless Wall Mounted Occupancy Sensor3 Notes: 1.Available functions/features may differ based on connected system. 2.Communication cable can be extended to a maximum of 164 feet. 3.Up to 10 door/window switches and ceiling/wall mounted sensors can be connected to the MUlti$ftE CRC1+ Remote Controller. 4.Must follow installation instructions in the applicable LG installation manual. E- 1 _ T _ T 4 t • BACnet° is a registered trademark of ASHRAE Life's Good Connectivity: • LG NiIoT.-: �toPM Oce Auto Heat `; t Indoor "P ;A} 740 �71 66% 451r fit tic,* LG Communications BACnet® MS/TP (default model) ZigBee Pro® wireless mesh network (P) (optional) 1 Channel/RS-485 V -Net Communications Cabling Specifications (V -Net): Type Size Length' 3 conductor, stranded, twisted, unshielded AWG 22-3 up to 164 ft AWG -American Wire Gage Unit Data: Dimensions 4.72" H x 3.39" W x 1.06" D Maximum Number of Indoor Units (per controller) 16 Maximum Number of Controllers (per group) 2 TERMINAL DESCRIPTION 4 (S) Tx - Rx Communication 5 (12V) 12 Volts DC 6 (G) Ground 13 BACnet + 14 BACnet - 15 MSTP Common Note: Terminals 1, 2, 3,16,17, and 18 are unused. For continual product development, LG reserves the right to charge specifications without notice. © LG Electronics U.S.A., Inc., Englewood Cliffs, NI. All rights reserved. "LG Life's Good" is a registered trademark of LG Corp. /www.lg-vrf.com SB_MuItiSITE_CRC1_Plus_PREMTBVC1_11_16 Page 1 of 3 Job Name/Location: PREMTBVC1 MuItiSITE CRC1+ Remote Controller Dimensions: 4.72"H x 3.39"W x 1.06"D i N ti 1 co 0 44111111 c 3.39" suomillow iMI 101HHOr _an0 Tag #: Room thermostats LG Date: Life's Good PO No.: a PPP@ ®® ®a® � rlr 0 0 0 d G 44 4 ©r 5MUM OM= 0 For continual product development, LG reserves the right to change specifications without notice. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG Life's Good" is a registered trademark of LG Corp. /www.lghvac.com SB_MuItiSITE_CRCl_Plus_PREMTBVC1_11_16 Page 2 of 3 Job Name/Location: PREMTBVC1 MuItiSITE CRC1+ Remote Controller Current Date Occupancy Status Occupied (Occ) or Unoccupied (Unocc) Room Indoor Temperature Room Indoor Humidity On/Off Turn the display on or off LG Life's Good Tag #: Room thermostats Date: PO No.: Operation Mode Set Cool, Heat, Auto Cool, Auto Heat, Fan, Dry modes El E3 Note: Pressing and holding the Operation Mode icon takes the user to the Operation Mode page. Recommended installation height for PIR sensor: 4 - 5 ft. / 1.2-1.5 m Sensor Ranges A=20ft./6.1 m B=14ft./4.3m C = 11 ft./3.4m Schedule - Set weekly schedule Short Network Message Horizontal Angles (Typical) Transverse motion: 4-5 ft/s / 1.5 m/s Center For continual product development, LG reserves the right to change specifications without notice. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG Life's Good" is a registered trademark of LG Corp. /www.lg-vrf.com Center Current Time Current Fan Speed Setting Operation Mode Status Up Arrow Raise Temperature Setpoint Down Arrow Lower Temperature Setpoint More Provides end user with access to less often used functions. Fan Speed Set fan to Slow, Low, Low -Med, Medium, Med-High, High, Power, Auto. (Available options depend on IDU model) M E3 Note: Long -press of the Fan Speed button when in cooling mode triggers Power Cooling mode. If in Power Cooling mode, last airflow segment on top is lit in purple and the text changes from °Fan" to "Power Cool". This mode lasts for 30 minutes and then reverts back to the previous fan speed. Vertical Angle (Typical) SB_MultiSltE_CRCl_Plus_PREMTBVCS_11_16 Page 3 of 3 MULTI V DUCTED HIGH STATIC External Static Pressure and Air Flow Tables BH, BG Units Table 19: BH Unit Extemal Static Pressure and Air Flow Table. Set Value Static Pressure (in. wg) 0.12 0.15 0.19 0.23 0.27 0.31 0.35 0.39 0.47 70 95 - - - - - - - - 80 187 - - - - - - - - 90 275 215 127 102 - -- - - - 100 360 286 212 134 117 -- - - - 110 445 410 311 258 208 148 - - - 120 554 501 420 357 297 230 177 155 - 130 632 583 547 466 417 339 268 215 152 140 724 671 622 569 540 459 427 364 205 145 756 703 682 618 569 509 480 392 279 150 795 752 703 667 622 565 505 491 364 Table 20: BG Unit External Static Pressure and Air Flow Table. Set Value Static Pressure (in. wg 0.12 0.16 0.19 0.23 0.27 0.31 0.35 0.39 0.47 0.55 0.62 0.7 70 339 184 - - - - - - - - - - 80 509 374 141 - - - - - - - - - 90 657 501 427 243 145 - - - - - - - 100 788 717 600 547 388 218 148 - - - - - 110 929 855 755 692 619 494 409 233 - - - - 120 1,049 971 911 847 769 699 632 515 427 - - - 130 1,180 1,102 1,059 1,006 951 893 826 769 639 515 399 - 140 1,317 1,271 1,271 1,133 1,073 1,024 968 914 762 628 512 332 143 1,349 1,324 1,324 1,197 1,133 1,084 1,017 960 812 709 593 441 150 1,448 1,437 1,447 1,432 1,271 1,218 1,133 1,063 928 791 642 558 160 - - 1,497 1,469 1,349 1,274 1,236 1,221 1,098 946 822 682 1. All static pressure air flow rates are listed in CFM. 2. The tables above show the correlation between air flow rates and external static pressure. 3. The tables above show the available external static pressure range. Note: If the external static pressure of the installed indoor unit is less than the lowest value (as mentioned in the table), the indoor unit components can fail. LG Due to our policy of continuous product innovation, some specifications may change without notification. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. At rights reserved. 'LT is a registered trademark of LG Corp. HIGH STATIC 1 29 O!;eM 46iH Pe;Dna ndoor Unit Engineering Manua MULTI V Ducted DUCTED HIGH STATIC External Static Pressure and Air Flow Tables BR, B8 Units MULTI V Table 21: BR Unit External Static Pressure and Air Flow Table. Set Value Static Pressure (in. wg) 0.19 0.23 0.31 0.39 0.47 0.55 0.59 0.62 0.66 0.70 0.78 91 1,642 1,543 1,349 1,105 819 494 317 130 - - - 96 1,762 1,628 1,518 1,183 1,098 649 483 317 91 - - 101 1,839 1,772 1,691 1,395 1,320 964 889 628 314 215 - 106 1,815 1,808 1,779 1,568 1,522 1,176 1,133 1,020 741 632 293 111 1,892 1,896 1,868 1,762 1,705 1,433 1,419 1,158 1,112 960 618 116 - - - 1,967 1,794 1.582 1,504 1,416 1,327 1,147 974 121 - - - - 1,843 1.794 1,776 1,613 1,575 1,370 1,137 126 - - - - - - 1,921 1,808 1,779 1,624 1,536 Table 22: B8 Unit Extemal Static Pressure and Air Flow Table. Set Value Static Pressure (in. wg) 0.23 0.35 0.47 0.59 0.71 0.79 0.86 0.90 0.98 60 1,430 - -- - - - - - 65 1,861 1,388 -- - - - - - 70 2,249 1,663 -- - - - - - 75 2,511 2.009 1,578 - - - - - - 80 2,694 2.461 1,949 -- - - - - 85 2,941 2,775 2,380 1,974 1,123 - - - - 91 3,167 3,076 2,786 2,387 1,914 - - - - 95 3,298 3,227 3,040 2,719 2,345 1,787 1,059 - - 100 3,298 3,227 3,118 2,998 2,680 2,454 2,147 1,522 - 105 3,291 3,224 3,118 2,998 2,864 2,733 2,443 2,398 1,811 1. All static pressure air flow rates are listed in CFM. 2. The tables above show the correlation between air flow rates and external static pressure. 3. The tables above show the available external static pressure range. Note: If the external static pressure of the installed indoor unit is less than the lowest value (as mentioned in the table), the indoor unit components can fail. Due to our policy of continuous product innovation, some specifications may change without notification. 30 1 HIGH STATIC © LG Electronics U.S.A.,Inc., Englewood Cliffs, NJ. All rights reserved."LG" is a registered trademark of LG Corp. • LG MULTIV DUCTED HIGH STATIC External Static Pressure and Air Flow Charts BH, BG Units Figure 12: BH Unit External Static Pressure and Air Flow Chart. 0.47 100 300 400 500 M Ffor*drn} 600 Figure 13: BG Unit External Static Pressure and Air Flow Chart. 700 0.65 3 0.55 co to N a ro0 V) 0.45 0.35 0.25 W 0.15 100 t.. •+• +;.i +• t+ •4 +r •+t. +4 r ! r 1- • . ES' nih •t +r 1 + • + r r r •• . i + + + • t :ESP ►►�� SetO x,,30 , Se ' ,�0 ` + \ ; ' 'fir 5etno, lio ktak. ilkh,1: ..• „, too ng� 111111111 + , +++ ! ... •• 300 500 700 900 1100 1300 Air Flow (CFM) 1500 ( LG Due to our policy of continuous product innovation, some specifications may change without notification. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved.'LG” is a registered trademark of LG Corp. HIGH STATIC 1 31 3ge;S 46!H Pelona ndoor Unit Engineering Manual MULTI V Ducted DUCTED HIGH STATIC External Static Pressure and Air Flow Charts BR, B8 Units MULTI V Figure 14: BR Unit External Static Pressure and Air Flow Chart. P 0.75 -+- 0.65 0.55 0.45 0.35 0.25 0.15 --- - 100 600 1600 Figure 15: B8 Unit External Static Pressure and Air Flow Chart. p 1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 ES i T Sett g L 105 1ES Setfi { 95. t j 'ES t =7 ;Setting i i . + 186" I Iii?a. 1000 1500 t ES Setting • 75 • 2000 Q (CFM) 2500 3000 Due to our policy of continuous product innovation, some specifications may change without notification. 32 I HIGH STATIC © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. Af! rights reserved. "LG" is a registered trademark of LG Corp. LG INSTALLATION INSTRUCTIONS 69 Installer Setting - E.S.P. Function This function determines the fan speed strength setting for each level (low, med, high). • If you set ESP incorrectly, the air conditioner may malfunction. • This setting must be carried out by a certificated -technician. i•UUu nri -i1:130 I; 123 1123 1A1 TEMP vJ FAN SPEED SET BACK 1 HOLD OPER MODE Function code, ESP code ESP value IPress the ID button for 3 seconds to enter Thermostat ul installer setup mode. ' - If pressed for a shorter time, it enters into user setup mode. 2 If entering into ESP setup mode by using Elbutton, it indicates as the picture below. UUO 03.0 1 00o 0301 ESP step Function Code ESP value 3 Select ESP fan step by pressing Q Q buttons. (01: very low, 02: low, 03: medium, 04: high, 05: very high) 07•U I ©L' 4 Move button. (000 default to is the ESP setting.) value factory setting by pressing O L_/1 5 Press Q Q buttons to setup ESP value. (It is possible to setup ESP value from 1 to 255, and 1 is G the 255 is the smallest and largest).) l • ESP settings vary between different product types. 70 INSTALLATION INSTRUCTIONS 7 6 Select ESP fan step again by using Q buttons and set up ESP values as No. 4 and 5 to correspond to each fan speed. O Function code, ESP code ESP value rAl TEMP vJ FAN SPEED BACK OPER MODE MIME 7 Press ml button to save. 8 Press ® button to exit. After setup, it automatically exits after 25 seconds if there is no input. If the Setting/Cancel button is not pressed, the mode will not change. i • Please be careful when adjusting ESP values. • It does not work to setup ESP value for weak/power step for some products. • ESP value range is dependent on product. nn uuo 0301; 6 Select ESP fan step again by using Q buttons and set up ESP values as No. 4 and 5 to correspond to each fan speed. O Function code, ESP code ESP value rAl TEMP vJ FAN SPEED BACK OPER MODE MIME 7 Press ml button to save. 8 Press ® button to exit. After setup, it automatically exits after 25 seconds if there is no input. If the Setting/Cancel button is not pressed, the mode will not change. i • Please be careful when adjusting ESP values. • It does not work to setup ESP value for weak/power step for some products. • ESP value range is dependent on product. New project ERV -01 throu E1800-Fi (ERV -112) - Submittal h ERV -10 - Rev. 1 Ventilation Summary Design Temperature - Winter Outdoor Air (DB) Outdoor Air (WB) Indoor Air (DB) Indoor Air (WB) Air Flow External Static Pressure Recovered Energy Heating Capacity Sensible Efficiency Latent Efficiency Total Efficiency New Air (DB) New Air (WB) Power Motor's Voltage FLA Rotationnal speed Starter Voltage FLA MCA MOP Fresh Air Blower Heating Capacity Supply Temperature - Winter Fresh Air Motor 23 °F 22 °F 70 °F 58 °F 450 CFM 0.75 in.w.c. 25 MBH 75 61.8 % 70.4 % 58.2 °F 49.4 °F Design Temperature - Summer Outdoor Air (DB) Outdoor Air (WB) Indoor Air (DB) Indoor Air (WB) Air Flow External Static Pressure Recovered Energy Cooling Capacity Sensible Efficiency Latent Efficiency Total Efficiency New Air (DB) New Air (WB) Electrical Load 295 watts per motor (2 motors per airstream) Power 120/1/60 Motor's Voltage 6.9 FLA 3050 RPM Rotationnal speed Magnetic Starter Unit's main Voltage 120/1/60 14 Exhaust Air Blower Cooling Capacity Supply Temperature - Summer Exhaust Air Motor 85 °F 67 °F 75 °F 62 °F 450 CFM 0.75 in.w.c. 0.4 Tons 75 % 58 % 69.2 % 77.5 °F 63.6 °F 295 watts per motor (2 motors per airstream) 120/1/60 6.9 3050 RPM Magnetic aldes American ALDES Ventilation Corporation 2 4521 19th Street Court East, Suite 104 Bradenton, FL 34203 - USA -1 941.351.3441 • 800.255.7749 • 941.351.3442 (fax) 2018-01-19 13:26:42 www.americanaldes.com Selector Aeromatic HRV/ERV v.1.6.0.3 New project ERV -01 through ERV -10 E1800-Fi (ERV -112) - Submittal - Rev. 1 Construction Cabinet type Exterior steel gauge Interior steel gauge Access Insulation Mounting Blower type Bearing Width Diameter Shaft Diameter Drive Power Type Efficiency Frame Speed(s) Mount Type Quantity per circuit Dimension Type Quantity Dimensions Spacing Condensation pan Core pan drain plug Position Cabinet Single-wall 22ga galvanized steel N/A Hinged Access Panels 1"(25 mm) Installation Platform Fresh Air Blower Backward -Inclined Plenum (twin) Permanently sealed and lubricated 3,5 in 10 in 1/2 in Direct transmission Fresh Air Motor Fresh Air Filters Recovery Core Blower type Bearing Width Diameter Shaft Diameter Drive 1.06 HP Power PSC Type EPAC Effidency Direct Frame 1 Speed(s) None Mount MERV8 3 15 5/8 x 15 5/8 x 3/8 in f Type Quantity per circuit Dimension Enthalpic Core 3.3mm High Efficency Core 3 Unit 16,34 x 16,34 x 15,67 in 3.3 mm 22ga galvanized steel OinNPT Front Intend( lialdes Exhaust Air Blower Backward -Inclined Plenum (twin) Permanently sealed and lubricated 3,5 in 10 in 1/2 in Direct transmission Exhaust Air Motor Exhaust Air Filters Warranty Certification 1.06 HP PSC EPAC Direct 1 None MERV8 3 15 5/8 x 15 5/8 x 3/8 in 10 -year limited 2 -year limited C22.2 no.113 UL 1812 aldes American ALDES Ventilation Corporation 4521 19th Street Court East, Suite 104 Bradenton, FL 34203 - USA 941.351.3441 • 800.255.7749 • 941.351.3442 (fax) www.americanaldes.com 3 -1 2018-01-19 13:26:42 Selector Aeromatic HRV/ERV v.1.6.0.3 New project E1800-Fi (ERV -112) - Submittal - Rev. 1 Dimensions Recirculation Port (H1800-Ri only) FRONT VIEW 28-5/8" (726 mm) SIDE VIEW 29-5/8" (753 mm) r aides American ALDES Ventilation Corporation 4 4521 19th Street Court East, Suite 104 Bradenton, FL 34203 - USA -1 941.351.3441 • 800.255.7749 • 941.351.3442 (fax) 2018-01-19 13:26:42 www.americanaldes.com Selector Aeromatic HRV/ERV v.1.6.0.3 12-1/2" mm)`,..,_ 24" (610 mm) x016 1..., L., 41-1/16" Anchor 01/2" u L. (1043 mm) (13 mm) a 48-7/8" (1242 mm) SIDE VIEW 29-5/8" (753 mm) r aides American ALDES Ventilation Corporation 4 4521 19th Street Court East, Suite 104 Bradenton, FL 34203 - USA -1 941.351.3441 • 800.255.7749 • 941.351.3442 (fax) 2018-01-19 13:26:42 www.americanaldes.com Selector Aeromatic HRV/ERV v.1.6.0.3 New project E1800-Fi (ERV -112) - Submittal - Rev. 1 Model Quantity Dimensions Spacing Air Flow (CFM) Temperature Dry Bulb (°F) Temperature Wet Bulb (°F) Relative Humidity (%) Enthalpy (BTU/Ib) Core Performance Enthalpic Core 3.3mm High Efficency 3 16,34 x 16,34 x 15,67 in 3.3 mm Entering Fresh Air T1 Summer Winter 450 450 85 23 67 22 39.06 87.39 31.41 ! 7.84 Entering Exhaust Air T3 Summer Air Flow (CFM) 450 Temperature Dry Bulb (°F) 75 Temperature Wet Bulb (°F) 62 Relative Humidity (%) 48.06 Enthalpy (BTU/lb) 27.71 Winter 450 70 58 48.29 25.01 Performance Summer Winter Sensible Efficiency (%) 75 75 Latent Efficiency (%) 58 61.8 Total Efficiency (%) 69.2 70.4 Recovered energy (Tons) 0.4 Recovered energy (MBH) 25 Exhitua Aii'F4 Summer 450 82.5 65.5 40.31 30.27 alter 450 35 34.8 98.55 12.9 Leaving Fresh Air T2 rSummer Winter 450 r 77.5 63.6 46.6 28.85 450 58.2 49.4 53.09 19.91 American ALDES Ventilation Corporation 5 4521 19th Street Court East, Suite 104 Bradenton, FL 34203 - USA -1 941.351.3441 • 800.255.7749 • 941.351.3442 (fax) 2018-01-19 13:26:42 www.americanaldes.com Selector Aeromatic HRV/ERV v.1.6.0.3 Section #2 Grilles Diffusers Louvers TAG: B Eggcrate ceiling grille �litus Submittal 50F —1.0 10-17-17 Eggcrate Return Grilles • Aluminum Grid • Aluminum Border 50F • Code A • 1/z x 1x'/2 Grid ❑ 50F • Code B • 1/2 x11/2 x 1 Grid ❑ 50F • CodeC • 1 x 1x 1 Grid O 50F -NT • Code A • 1/2 x 1/2 x 1/2 Grid • Narrow Tee Border O 50F -NT • Code B • 1/2 x 1/2 x 1 Grid • Narrow Tee Border O 50F -NT • Code C • 1 x 1 x 1 Grid • Narrow Tee Border ❑ Border Type 1 (Surface Mount) —o]1 114" Optional — Opposed Blade Damper Available Sizes (D" x D") D plus 1 314" D minus 3/4" D minus 112" Nominal Duct Size D" 3/16" Border Type 1 available in sizes 6" x 4" through 48" x 48" in one piece construction. Sizes larger than 48" x 48" are shipped in multiple sections. Odd and fractional sizes are available at additional cost. Wall or duct opening should be duct size ± 1/8. All dimensions are in inches. Check One [V]" t ■ ■ Dimension 1/2"x %"x%" %"x1/2"x1" 1"x1"x1" J 1'h" 1'h" 11" K 2 '/2" 2 15/16" 2 15/16" Fastenings ❑ Type A • Extemal Screw ❑ Type C • Concealed Screw ��. Duct Size minus 3/4" 3/16" 1 1/4" �—+-- Duct Size —� Available with Border Type 1 only. Type 'C' fastening not available on unit with damper. Duct Accessories (Optional) Check miff provided. ❑ Neck mounted opposed bladeD damper (galvanized steel) ❑ EQT • Earthquake Tabs General Description Mounting Frames ❑ PFAP • Aluminum Plaster Frame f— Duct plus 2 3/8" Duct plus 1 7/8" 1/4" 5/16" 3/16" 1 1/2" Duct plus 1/16" Recessed Mounted Example Note: Plaster frame can be installed as either surface mount or recessed. Dimensions are in inches. Wall or duct opening should be duct sizes+ 118. IS • Insect Screen (1/16" square mesh — galvanized steel) ❑ DS • Debris Screen (1/4" square mesh — galvanized steel) ❑ Other: Standard Finish: #26 White ❑ Other Finish: • #8 x 1 1/4 lg. Phillips flat head • Optional opposed blade damper has sheet metal screws painted white. screwdriver adjustment accessible • Insect and debris screens are not through face of grille. available when dampers are fitted. • Material is aluminum. • All dimensions are ± 1/16" Optional Border Types Available Border Type 3 (Lay -in) Panel Mounted Ceiling Module Size -mid minus 1/4" Available as panel -mounted in all standard module sizes with neck sizes up to module size minus 2". Note: Module size minus 2" sizes do not require panel mounting. Border Type 3 • Accessories & Options 50F 2.0 10-17-17 Check [v](if provided. Neck mounted opposed blade damper (galvanized steel) IS • Insect Screen (1/16" square mesh — galvanized steel) DS • Debris Screen (1/4" square mesh — galvanized steel) EQT • Earthquake tabs Other: Note: Insect and Debris Screen are not available with Damper option > Standard Finish: #26 White ❑ Other Finish: Square to Round (SRG) ter P ( ) BEAD NOM INLET -118" - 23-3/4" Adapter interior is black and factory -mounted to grille 2-1/2" 3.1/4" 24 X 24 Module Size Nominal Grille Size Nominal Round Inlet Size 6 8 10 12 22x22 14 16 18 20 ❑ Border Type NT (Lay -in) Panel Mounted a♦ L� 5/16",J L.._9116" 24" D minus 112" Optional Opposed Blade Damper �— D minus 314" --� 23 318" 23 314" Available Sizes (D" x D") 6" x 4" through 22" x 22" in 1" Increments. Dimensions are in inches. ❑ Border Type 7 (Channel) 1/4" �1 I1 1 " i I k 1 1 1 1 1 1 1 111 1 5/8" 1 1/8" Ceiling Module Size Minus 1/4" Available in sizes up to 48" x 48". Available in sizes up to 48" x 48" Border Type NT Check B" if provided. • Accessories & Options D Neck mounted opposed blade damper (galvanized steel) ❑ EQT • Earthquake Tabs ❑ 1S • Insect Screen (1/16" square mesh — galvanized steel) ❑ DS • Debris Screen (1/4" square mesh — galvanized steel) ❑ Other: Note: Insect and Debris Screen are mutually exclusive options Standard Finish: #26 White ❑ Other Finish: Border Type 7 and 8 • Accessories & Options ❑ EQT • Earthquake tabs ❑ Other: Standard Finish: #26 White ❑ Other Finish: Check g if provided. This submittal is meant to demonstrate general dimensions of this product. The drawings are not meant to detail every aspect of the product. Drawings are not to scale. Titus reserves the right to make changes without written notice. Al rights resawd. No pert d this work maybe reproduced a o-ananned in any fam or byaiy mems. electron or mmtenbd, hchdng phdompyhg aid moordhp orb/ my irfomalon storage retdeiel system winos psnn'sam h wriim tram At Dchbotbnmd,ncbpes. TAG: R Return air grilles *Titus Submittal 350R 1.0 11-30-11 Louvered Return Grilles • Steel Models:] 350RL • 35° Deflection • Long Blades • 3/4" Blades Spacing ❑ 350RS • 35° Deflection • Short Blades • 3/4" Blades Spacing ❑ Border Type 1 (Surface Mount) 1 1/4" 9/16" -•- Screwdriver Screwdriver - Slot Operator For Optional Damper Optional Model AG -15 Opposed Blade Damper D plus 1 3/4" 3/4" 2P'" 35° 'lift/ fffit fit f D minus 1/4" Nominal Duct Size D " 1/4" 1 1 1-11/4" t 2 5i/8" Note: When Damper Is Full Open Add 3/8" To Overall Depth. Available Sizes (D" x D") Border Type 1 is available in sizes 6" x 4" through 48" x 48" in 1" increments in one piece construction. Odd and fractional sizes are available at additional cost. Sizes larger than 48" x 48" are shipped in multiple sections with janing strips for field assembly. Note: Wall or duct opening should be duct size ± 1/8". All dimensions are in inches. Fastenings ❑ Type A • External Screw ❑ Type C • Concealed Screw Duct Size manus 3/4" 1 1/4" x 3/4" Angle Clip Attached To Grille (By Titus) #8 Screw 1 1/4" x 314" Angle Clip (By Others) (By Others) —.I Duct Duct Size Available with Border Type 1 only. Type C fastening available with damper. Mounting Frames ❑ PF • Steel Plaster Frame Duct plus 2 3/8" Duct plus 1 7/8" 114"- 1/4" 5/16" 114" 5/16" ❑ PFA • Aluminum Plaster Frame -� Duct plus 2 3/8" Duct plus 1 7/8" 1/4" 1 1/2" Duct plus 1/16" +� 1- Duct plus 1/16" —.- Surface ►Surface Mounted Example Recessed Mounted Example Note: Wall opening should be listed duct size + 118" to listed duct size + 1/4". Accessories (Optional) Check [ if provided. ❑ Neck mounted opposed blade IS • Insect Screen (1/16" square damper (galvanized steel) mesh - galvanized steel) ❑ EQT • Earthquake Tabs General Description ❑ DS • Debris Screen (W square mesh - galvanized steel) 0 Other: Standard Finish: #26 White ❑ Other Finish: • Material is Steel. • Available with louvers vertical or horizontal. • #8 x 11/4" Ig. Phillips flat head sheet metal screws painted white. • Optional opposed blade damper has screwdriver adjustment accessible through face of grille. • All dimensions are ± 1/16". This submittal is meant to demonstrate general dimensions of this product. The drawings are not meant to detail every aspect of the product. Drawings are not to scale. Titus reserves the right to make changes without written notice. All rights reserved. No part of this work maybe reproduced or transmitted in any brm or by any means, electronic or mechanical. Including photocopying and rwording, or by any Information storage retrieval system without permission in wilting from Air Distribution Technologies. Optional Border Types Available ❑ Border Type 2 (Snap -in) Panel Mounted Ceiling Module Size minus 1/16" &7-73L Available in 24" x 24" modules with neck sizes up to 20" x 20". ❑ Border Type 4 (Spline) Panel Mounted Ceiling Module Size plus 3/4" Available in 24" x 24" modules with neck sizes up to 20" x 20". Splines on 2 opposite sides only Border Type 2, 3, 4, NT • Accessories & Options Check [fif provided. ❑ AG -15 • Neck mounted opposed blade damper (galvanized steel) ❑ IS • Insect Screen (1/16" square mesh — galvanized steel) ❑ DS • Debris Screen (1/4" square mesh — galvanized steel) ❑ EQT • Earthquake tabs ❑ Other: Standard Finish: #26 White ❑ Optional finish: 350R 2.0 11-30-11 Border Type 3 (Lay -in) Panel Mounted Ceiling Module Size minus 1/4" Available in all standard module sizes with neck sizes up to module size minus 2". ❑ Border Type NT (Narrow Tee) 5/16" CEILING MODULE MINUS 3/4" NT Border is available in module sizes 24" x 12" & 24" x 24" only. This submittal is meant to demonstrate general dimensions of this product. The drawings are not meant to detail every aspect of the product. Drawings are not to scale. Titus reserves the right to make changes without written notice. All fights reserved. No part of Iles work may be reproduced or transmitted h any form or by.ny means, electronic or mechanical, including photocopyhg and recording, or by any Information Maser. retrieval system wldiout permission in wdarg from Air ointration Technologies. *Titus Submittal TMSA-AA 1.0 4-6-15 Square Ceiling Diffusers Aluminum • Adjustable • High Performance Model: TMSA-AA • Round Neck • Vertical -to -Horizontal Discharge Pattern Border Type 3 (Lay -In) Full Face. Pattern Controller Vane Ceiling Module A Imo- Nominal Round Duct Size B it B minus 1/8" 1 c Ceiling Module A minus 3/8" Ceiling Module A Nominal Round Duct Size B C D E 12 x12 4, 5* 3 1/8 5 3/8 3/8 12x12 6,7 11/8 33/8 3/8 12 x12 8 1 1/4 3 1/2 3/8 20 x20 4, 5* 2 3/4 6 3/8 1 1/4 20 x20 6, 8, 10 3/4 4 3/8 1 1/4 24 x24 6, 8 1 1/4 5 1/4 24 x24 10, 12, 14, 15 1 3/8 5 1/8 1/4 * Adapter is provided for 4 & 5 Other Available Border Types ❑ Frame Type 1 (Surface Mount) Full Face Ceiling Module A, plus 1 1/2" Ceiling Module plus 1/4" —+{ 11/4" 1/4" Ceiling Module Face Size Nominal Round Duct Sizes Border Types 20 x 20 20 x 20 4, 5, 6, 8, 10 1, 3 24 x 24 24 x 24 6, 8, 10, 12, 14, 15 1, 2, 3, 4 TMSA-AA 2.0 4-6-15 Adjusting Optional Damper • Removing Center Cone 1. Remove center pin. 2. To adjust optional damper, insert screwdriver through hex hole. 3. To remove center cone, insert hex key (by others) and unscrew center hub. TMSA-AA Discharge Patterns Vertical Pattern Note: Pattern controller vanes are adjustable to any position from vertical to horizontal. Horizontal Pattern Accessories (Optional) Check [rif provided. ❑ Model D-75 Opposed Blade Damper Model EG Equalizing Grid EG D-75 1 112" Mounts on Neck A J Model D-75 damper is available in duct sizes 6 thru 12 inches only. ❑ Model AG -85 Butterfly Damper ❑ Model EG Equalizing Grid ❑ Model AG -75 Opposed Blade Damper ❑ Model EG Equalizing Grid EG AG -75 1 1/2" J Mounts Above Neck Model AG -75 damper is avai able in 6, 7, 8, 10, 12, 14, and 15 inch duct sizes only. Size B 6-12 1 1/2 14, 15 2 1/8 O Model AG -65 Combination Damper and Equalizing Grid Air Flow AG -65 t Mounts Above Neck A T1 1 1 1/2" ❑ Model D-100 Radial Sliding Blade Damper ❑ Model EG Equalizing Grid L 1 1/2" EG D-100 Mounts on Neck P Model D-100 damper is available in duct sizes 6, 8, 10, 12 and 14 inch duct sizes only. Dimension "A" in Inches, for Dampers Shown as Above TMSA-AA 3.0 4-6-15 ❑ Model AG -100 Radial Sliding Blade Damper ❑ Model EG Equalizing Grid AG -100 EG Mounts Above Neck 1 1/2" Model AG -100 damper is available in duct sizes 6, 8, 10, 12 and 14 inch duct sizes only. Accessories Nominal Round Duct Sizes 6 7 8 10 12 14 15 AG -100 — — — — — — N/A D-100 — — — — — — N/A D-75 2 3/8 27/8 3 1/4 4 1/8 4 7/8 N/A N/A AG -85 21/2 3 31/2 41/2 51/2 61/2 7 AG -65 3 3/8 4 4 1/2 5 1/2 7 1/8 8 5/8 9 AG -75 2 3/4 3 1/4 3 5/8 4 1/2 5 3/8 i 2 3/4 3 Other Accessories (Optional) 0 Model SB Sectorizing Baffles Note: D-100 and AG -100 dampers have radial blades that slide in a horizontal plane. For that reason, no opening clearance "A" is dimensioned. Standard Finish: #26 White F - General Description • Model TMSA-AA includes adjustable vanes which vary the discharge pattern between horizontal and vertical. • Delivers supply air in a true 360° pattern. Designed to protect ceiling from streaking and smudging. • Excellent for variable volume systems. The uniform, nearly horizontal jet maintains effective room air distribution even when air volume varies over a considerable range. The TMSA-AA consists of 3 concentric cones in all sizes. This uniformity of design enhances appearance in installations where more than one size is involved. Screwdriver adjustment of the optional damper is achieved without removing the inner cone. (See Note 2, page 2.) Quick removal of inner cone with a hex key speeds installation. (See Note 3, page 2.) • All cones are die -stamped one- piece construction with smooth, clean surfaces and no corner joints. • Material is heavy gauge aluminum with steel bar webbing. This submittal is meant to demonstrate general dimensions of this product. The drawings are not meant to detail every aspect of the product. Drawings are not to scale. Titus reserves the right to make changes without written notice. All fights reserved. No pert of this work may be reproduced or transmitted in any form or by any means, electronic or mechanical, Including photocopying and recording, or by any information storage retrieval system without permission In writing from Air Distribution Technologies. *RUSKIN 3900 Dr. Greaves Rd. Kansas City, MO 64030 • (816) 761-7476 • FAX (816) 765-8955 ELF375DX DRAINABLE STATIONARY LOUVERS EXTRUDED ALUMINUM STANDARD CONSTRUCTION FRAME 4" (102) deep, 6063T6 extruded aluminum. .081" (2.1) nominal wall thickness. Downspouts and caulking surfaces provided. BLADES 6063T6 extruded aluminum. .081" (2.1) nominal wall thickness. Drainable blades are positioned at 371/2° angle and spaced approximately 53/32" (129) center to center. SCREEN 5/e" x .040" (16 x 1) expanded, flattened aluminum bird screen in removable frame. Screen adds approximate- ly 1/2" (13) to louver depth. FINISH Mill. MINIMUM SIZE 12"w x 12"h (305 x 305). APPROXIMATE SHIPPING WEIGHT 4 lbs./ft.' (19.5 kg/m2). MAXIMUM FACTORY ASSEMBLY SIZE Single sections shall not exceed 120"w x 90"h (3048 x 2286) or 90"w x 120"h (2286 x 3048). Louvers larger than the maximum single section size will require field assembly of smaller sections. BLADE SUPPORTS Louvers may be provided with rear mounted blade supports that increase overall louver depth depending on louver size, assembly configuration or windload. Consult Ruskirle for additional information. LEED Material Information Contact Ruskin for Recycled Material and Manufacturing Location Information. Dimensions in inches, parenthesis ( ) indicate millimeters. (102) Bird Screen FEATURES The ELF375DX offers: • 54% Free Area. • Published performance ratings based on testing in accordance with AMCA Publica- tion 511. • High performance frame system with drain- able head collects and removes water to provide excellent water penetration perfor- mance. • Drain gutter in each blade minimizes water cascade between blades. • Architecturally styled, hidden mullions allow- ing continuous line appearance up to 120" (3048). • Aluminum construction for low maintenance and high resistance to corrosion. • All welded construction. VARIATIONS Variations to the basic design of these louvers are available at additional cost. They include: • Extended sill. • Hinged frame. • Front or rear security bars. • Filter racks. • A variety of bird and insect screens. • Selection of finishes: prime coat, 50% PVDF, 70% PVDF, epoxy, Pearledize 50 & 70 (mica), clear and color anodize. (Some varia- tion in anodize color consistency is possible.) Consult RuskirP for other special requirements. A*xB* FRAME CONSTRUCTION 11/e (38) �2 STANDARD INTEGRAL FLANGE *Units furnished 1/4" (6) smaller than given opening dimensions. TAG QTY. SIZE FRAME VARIATIONS A* -WIDE B* -HIGH Waiting on confirmation of louver sizes PROJECT LOCATION ARCHJENGR. CONTRACTOR REPRESENTATIVE DATE ELF375DX-717/Replaces ELF375DXIELF375DXH-610 ALL STATED SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE OR OBUGATION. ©Ruskin July 2017 SUGGESTED SPECIFICATION GENERAL Furnish and install at locations shown on the plans or as described in schedules drainable louvers. Stationary louvers shall be manu- factured in an 1S0 9001 certified factory. Stationary louvers shall be furnished with bird and/or insect screens, supports and finishes as specified and as required for a complete installation. Stationary louvers shall incorporate drainable stationary blade. All blades and frames shall be constructed of 6063-T6 aluminum alloy. MATERIAL Stationary louvers shall be 4" (102) deep. Louver blade and frame nominal wall thickness shall be .081" (2.1) for ELF375DX Integral gutters shall be incorporated into blades, louver head and jamb frames. PERFORMANCE The louver shall be AMCA certified for Water Penetration and Air Performance conforming to the following minimum requirements: Free Area: 8.58 Square Feet (0.80 m2). Maximum pressure drop at 1000 fpm (305 m/min): 0.20" w.g. (0.05 kPA). Free Area Velocity at Beginning Point of Water Penetration: 873 fpm (+266 m/min). PERFORMANCE DATA AMCA Standard 500 provides a reasonable basis for testing and rating louvers. Testing to AMCA 500 is performed under a certain set of laboratory conditions. This does not guaran- tee that other conditions will not occur in the actual environ- ment where louvers must operate. The louver system should be designed with a reasonable safety factor for louver performance. To ensure protection from water carryover, design with a performance level somewhat below maximum desired pressure drop and .01 oz./sq. ft. of water penetration. STRUCTURAL DESIGN Integral structural supports shall be designed and furnished by the louver manufacturer to carry a wind load of not less than 20 psf (.96 kPA). FINISH Stationary louvers shall be finished as specified by the architect. Painted finishes shall include the following minimum requirements. All Kynar finishes shall be applied at 1.2 mil total dry film thickness and meet the following AAMA standards. 70% Kynar finishes shall meet AAMA 2605-05 for organic coatings and exterior aluminum finishes requiring 10 years of South Florida exposure. 50% Kynar finishes shall meet AAMA 2604-05 for organic coatings and exterior aluminum finishes requiring 5 years of South Florida exposure. Louver manufacturer shall provide 20 year limited warranty for fluo- ropolymer-based finishes. 10 -year warranties shall not be accept- able. Finish coating shall not peel, blister, chip, crack or check. Chalking and fading of finish shall not exceed the maximum limits identified in the manufacturers finish warranty. This warranty shall begun on the date of material shipment. Stationary Louver shall be Ruskin° model ELF375DX (Consult www.ruskin.com for electronic version of this "Quick" spec as well as for complete 3- part CSI MasterFormat Specifications). WATER PENETRATION Test size 48" wide x 48" high (1219 x 1219) Beginning point of water penetration at .01 ozJsq. ft. is 873 fpm (266 m/min). 0.3 (3.23) to 0 (2.69) 0 L u- F O . 0.2 N tri U - 0.15 C .� of LO C ea 0.1 (1.08) 0 0.25 (2.15) (1.61) 0.05 (.54) 0 800 (244) 900 (274) 1000 (335) 1100 (366) Free Area Velocity in feet and (meters) per minute Standard air .075 Ib/ft3 Static Pressure Drop in Inches w.g. and (mm) Height — Inches and Meters FREE AREA GUIDE Free Area Guide shows free area in ft2 and m2 for various sizes of ELF375DX Width - Inches and Meters 1.00 248.9) .90 224.01) .80 199.12) .70 (174.23) .60 (149.34) .50 (124.45) .40 (99.56) .30 (74,67) .20 (49.78) .10 (24.89) .09((22.40)) .08 19.91 .07 (17.42) .06 (14.93) .05 (12.45) .04 (9.96) .03 (7.47) .02 (4.98) .01 (2.49) PRESSURE DROP \FA KE HAU ST to s 0 0 0 0 0 0 0 0 Air Velocity in feet and (meters) per minute through Free Area (Data corrected to standard air density and AMCA figure tested to 5.5) 1.00 .90 .80 .70 .60 .50 .40 .30 .20 .10 .09 .08 .07 .06 .05 .04 .03 .02 .01 Ratings do not include the effect of a bird screen. amca WORIDRIDE OERTIr1ED RRTINS WATER ram�nOI MKOI.o1 AI ry eorcacnr no cowmen 0A° nuocunon unnnanonm. inc. Ruskin° Company certifies that the ELF375DX Louvers shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures per -formed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to air performance ratings and water penetration ratings only. 12 0.30 18 0.46 24 0.61 30 0.76 36 0.91 42 1.07 48 1.22 54 1.37 60 1.52 66 1.68 72 1.83 78 1.98 84 2.13 90 2.29 96 2.44 102 2.59 108 2.74 114 2.90 120 3.05 12 0.30 0.26 0.02 0.41 0.04 0.56 0.05 0.71 0.07 0.87 0.08 1.02 0.09 1.17 0.11 1.33 0.12 1.48 0.14 1.63 0.15 1.79 0.17 1.94 0.18 2.09 0.19 2.24 0.21 2.40 0.22 2.55 0.24 2.70 0.25 2.86 0.27 3.01 18 0.46 0.61 0.06 0.97 0.09 1.33 0.12 1.70 0.16 2.06 0.19 2.43 0.23 2.79 0.26 3.15 0.29 3.52 0.33 3.88 0.36 4.25 0.39 4.61 0.43 4.97 0.46 5.34 0.50 5.70 0.53 6.06 0.56 6.43 0.60 6.79 0.63 0.28 7.16 24 0.61 0.87 0.08 1.40 0.13 1.92 0.18 2.45 023 2.97 0.28 3.50 0.33 4.02 0.37 4.55 0.42 5.07 0.47 5.60 0.52 6.12 0.57 6.65 0.62 7.17 0.67 7.70 0.72 8.22 0.76 8.75 0.81 9.27 0.86 9.80 0.91 0.67 10.32 30 0.76 1.14 0.11 1.83 0.17 2.51 0.23 3.20 0.30 3.89 0.36 4.57 0.42 5.26 0.49 5.94 0.55 6.63 0.62 7.32 0.68 8.00 0.74 8.69 0.81 9.37 0.87 10.06 0.93 10.74 1.00 11.43 1.06 12.12 1.13 12.80 1.19 0.96 13.49 1.25 36 0.91 1.33 0.12 2.13 0.20 2.92 0.27 3.72 0.35 4.52 0.42 5.31 0.49 6.11 0.57 6.91 0.64 7.70 0.72 8.50 0.79 9.30 0.86 10.09 0.94 10.89 1.01 11.69 1.09 12.49 1.16 13.28 1.23 14.08 1.31 14.88 1.38 15.67 1.46 42 1.07 1.60 0.15 2.55 0.24 3.51 0.33 4.47 0.42 5.43 0.50 6.39 0.59 7.34 0.68 8.30 0.77 9.26 0.86 10.22 0.95 11.18 1.04 12.13 1.13 13.09 1.22 14.05 1.31 15.01 1.39 15.96 1.48 16.92 1.57 17.88 1.66 18.84 48 1.22 1.86 0.17 2.98 028 4.10 0.38 5.22 0.49 6.34 0.59 7.46 0.69 8.58 0.80 9.70 0.90 10.82 1.01 11.93 1.11 13.05 1.21 14.17 1.32 15.29 1.42 16.41 1.52 17.53 1.63 18.65 1.73 19.77 1.84 20.89 1.94 1.75 22.00 54 1.37 2.13 0.20 3.41 0.32 4.69 0.44 5.97 0.55 7.25 0.67 8.53 0.79 9.81 0.91 11.09 1.03 12.37 1.15 13.65 1.27 14.93 1.39 16.21 1.51 17.49 1.63 18.77 1.74 20.05 1.86 21.33 1.98 22.61 2.10 23.89 2.22 2.04 25.17 60 1.52 2.40 0.22 3.84 0.36 5.28 0.49 6.72 0.62 8.16 0.76 9.61 0.89 11.05 1.03 12.49 1.16 13.93 1.29 15.37 1.43 16.81 1.56 18.25 1.70 19.69 1.83 21.13 1.96 22.57 2.10 24.01 2.23 25.45 2.37 26.90 2.50 2.34 28.34 66 1.68 2.59 0.24 4.14 0.38 5.69 0.53 7.24 0.67 8.79 0.82 10.35 0.96 11.90 1.11 13.45 1.25 15.00 1.39 16.55 1.54 18.11 1.68 19.66 1.83 21.21 1.97 22.76 2.12 24.31 2.26 25.86 2.40 27.42 2.55 28.97 2.69 2.63 30.52 72 1.83 2.85 0.26 4.57 0.42 6.28 0.58 7.99 0.74 9.71 0.90 11.42 1.06 13.13 1.22 14.84 1.38 16.56 1.54 18.27 1.70 19.98 1.86 21.70 2.02 23.41 2.18 25.12 2.33 26.83 2.49 28.55 2.65 30.26 2.81 31.97 2.97 2.84 33.69 78 1.98 3.12 0.29 5.00 0.46 6.87 0.64 8.74 0.81 10.62 0.99 12.49 1.16 14.37 1.34 16.24 1.51 18.11 1.68 19.99 1.86 21.86 2.03 23.74 2.21 25.61 2.38 27.48 2.55 29.36 2.73 31.23 2.90 33.10 3.08 34.98 3.25 3.13 36.85 84 2.13 3.39 0.32 5.43 0.50 7.46 0.69 9.50 0.88 11.53 1.07 13.57 1.26 15.60 1.00 17.63 1.64 19.67 1.83 21.70 2.02 23.74 2.21 25.77 2.39 27.81 2.58 29.84 2.77 31.88 2.96 33.91 3.15 35.95 3.34 37.98 3.53 3.42 40.02 90 2.29 3.66 0.34 5.86 0.54 8.05 0.75 10.25 0.95 12.44 1.16 14.64 1.36 16.83 1.56 19.03 1.77 21.23 1.97 23.42 2.18 25.62 2.38 27.81 2.58 30.01 2.79 32.20 2.99 34.40 3.20 36.60 3,40 38.79 3.60 40.99 3.81 3.72 43.18 4.01 1.00 248.9) .90 224.01) .80 199.12) .70 (174.23) .60 (149.34) .50 (124.45) .40 (99.56) .30 (74,67) .20 (49.78) .10 (24.89) .09((22.40)) .08 19.91 .07 (17.42) .06 (14.93) .05 (12.45) .04 (9.96) .03 (7.47) .02 (4.98) .01 (2.49) PRESSURE DROP \FA KE HAU ST to s 0 0 0 0 0 0 0 0 Air Velocity in feet and (meters) per minute through Free Area (Data corrected to standard air density and AMCA figure tested to 5.5) 1.00 .90 .80 .70 .60 .50 .40 .30 .20 .10 .09 .08 .07 .06 .05 .04 .03 .02 .01 Ratings do not include the effect of a bird screen. amca WORIDRIDE OERTIr1ED RRTINS WATER ram�nOI MKOI.o1 AI ry eorcacnr no cowmen 0A° nuocunon unnnanonm. inc. Ruskin° Company certifies that the ELF375DX Louvers shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures per -formed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to air performance ratings and water penetration ratings only. TYPICAL INSTALLATION DETAILS Masonry Wall Metal Panel Wall CMU Sealant (by others) Louver Extended Sill Installation Angle (optional) Corrugated Metal Insulation Drip Cap (optional) Installation Angle (optional) Louver Sealant (by others) Extended Sill Wood Installation Sealant (by others) Louver Installation Angle (optional) Sheating Siding Louver Frame Louver CMU Flange Mount RUSKIN® 3900 Dr. Greaves Rd. Kansas City, MO 64030 (816) 761-7476 FAX (816) 765-8955 www.ruskin.com Options are available at additional cost. Fasteners into substrate are not provided by Ruskin9. LJ RUSKIN AUTHORITY IN AIR CONTROL RUSKIN finishes enhance product appearance to blend with other colors selected. These same finishes provide extended weathering resistance similar to adjacent building surfaces. RUSKIN provides most finishes available to architects and engineers. The standard finishes described herein represent those finishes usually selected, specified, or required for most applications. Finishes and Color Guide 2 Coat - 50% and 70% PVDF - Standard Colors The 15 colors below are available in 2 Coat (50% PVDF) or 2 Coat (70% PVDF) finishes only. * BONE WHITE (24) • DARK BRONZE (75) • LIGHT STONE (43) * SANDSTONE (67) * SAHARA TAN (65) * BLACK (89) • SHELBURNE (69) * HERRINGBONE (37) • STONE GRAY (78) " MEDIUM BRONZE (72) "PORTLAND STONE (49) * FOREST GREEN (36) • CORONADO RED (34) * ASCOT WHITE (19) • TAUPE (52) Pearledize 70 and Pearledize 50 Standard Colors The 9 colors below are available in Pearledize 70, Pearledize 50, Clear or Color Anodize finishes only, and may be more expensive than the 50% and 70% PVDF colors shown above. Italicized color names and codes are available in Anodized Finish. • DARK BRONZE (75) * DARK BRONZE (75) * BRIGHT SILVER (88) * Clear 204R1 & 215R1 (00) • COPPER (92) * MEDIUM BRONZE (72) * CHAMPAGNE BRZ (71) MEDIUM BRONZE (72) " CHAMPAGNE BRZ (71) • WARM SILVER (96) • ASTI (86) • CORAL REEF (93) • BLUE (05) * Denotes RUSKIN Color Code - Please use when ordering. This color card is for reference only and is not meant to be used for color matching or final color approval. Shades may vary due to the color and resolution of monitors or print-outs. RUSKIN is not responsible for color matches made with this online color chart. Phone: (816) 761-7476 • FAX• (816) 765-8955 • e-mail: ruskin@ruskin.com • RUSKIN.com • 3900 Dr. Greaves Rd., Kansas City, Missouri 64030 Finishes and Color Guide Factory finishes by RUSKIN are designed for low VOC emissions and eliminate the risk of VOC emissions found in louver finishes that are applied on site. All RUSKIN manufacturing facilities operate in full compliance with all applicable air permitting regulations. All facilities maintain ISO 14001 Environmental Management Systems which include VOC emission reduction strategies including state of the art spray equipment and operator training. Type of Finish Finish Specifications 2 Coat - 70% PVDF RUSKIN Superior Finish: 2 Coat 70% PVDF paint finishes provide maximum resistance against color fade and chalking. This carbon/fluorine bond, unique to the resin, when coupled with the finest inorganic pigments, produces the most durable and long lasting finish in the industry. These finishes are resistant to most chemicals, acid rain, salt spray and general air pollution. RUSKIN offers a twenty- year warranty on these finishes in standard colors on standard extruded aluminum products. All standard colors meet or exceed AAMA 2605-13.* Before paint application, louvers shall be thoroughly cleaned and pretreated to assure maximum performance. PVDF finish shall be applied to provide 1.2 mils (30pm) factory applied, baked -on film in accordance with AAMA 2605-13* "Voluntary Specification Performance Requirements and Test Procedures for Superior Performing Organic Coatings on Architectural Extrusions and Panels". Color shall be RUSKIN (specify color name and number). 2 Coat - 50% PVDF RUSKIN'S High Performance Finish: 2 Coat 50% PVDF finishes provide fluoropolymer benefits such as long color life and resistance to chalking and chemicals. For optimization of the price -benefit ratio, they are appropriate coatings for today's non -monumental projects. Ten-year warranty for standard color on standard extruded aluminum products is also available for RUSKIN'S PVDF. Louvers shall receive factory applied, baked -on 2 Coat 50% PVDF based color coating following thorough cleaning and pretreatment of metal. The finish shall be applied at 1.2 mils (30pm) total dry film thickness in accordance with AAMA 2604-13t Color shall be RUSKIN (specify color name and number). PRIME COAT Preparation for field painting. Finish may be topcoated with epoxy, vinyl, urethane and other heavy-duty coatings within six months of applications. Prime coat contaminations always occurs before field painting and requires thorough field cleaning prior to painting. Louvers shall receive prime coating following thorough cleaning and pretreatment of metal. Field topcoat with epoxy, vinyl, urethane or other heavy-duty coating within six months of application. Prime coat shall be a minimum of .3 ± .1 mils (8 ± 3pm) thick. PEARLEDIZE 70 AND PEARLEDIZE 50 RUSKIN'S High Pearlescent (Finish. Pearledize is a PVDF-based finish that utilizes pearlescent mica flakes to simulate the metallic appearance of anodized and metallic paint finishes. Available as Pearledize 70 (70% PVDF) and Pearledize 50 (50% PVDF), Pearledize 70 meets the AAMA 2605-13* specification while Pearledize 50 meets the AAMA 2604-13t specification. A ten-year warranty is available on standard colors on standard extruded aluminum products. Louvers shall receive thorough cleaning and pretreatment as described above. Pearledize coating shall be applied and baked to achieve a hard durable finish in compliance with either AAMA 2605-13* or AAMA 2604-13t as selected and specified. Color shall be RUSKIN (specify color name and number). COLOR ANODIZE Electrolytically deposited coating on aluminum: The color anodize process specified in Aluminum Association Code AA-C22A44 electrolytically deposits inorganic color pigment finish to a 0.7 mil (18pm) minimum surface depth on sulfuric acid anodized aluminum. Treated aluminum is sealed to convert a freshly formed aluminum oxide finish to a corrosion resistant, inert condition. Available only on aluminum. Some shade variation may occur. Louvers shall receive electrolytically deposited color anodized finish complying with Aluminum Association Code AA-C22A44. Finish is applied to 0.7 mils (18pm) minimum thickness onto chemically etched and pretreated aluminum. Color shall be RUSKIN (specify color name). CLEAR ANODIZE Clear oxide coating for aluminum: Clear anodize preoxidizes the aluminum surface for uniform clear finish not easily affected by natural oxidizing influences. Improved metallic luster appearance is similar to mill finish. 204-R1 (Aluminum Association Code AA-C22A31) provides 0.4 mi (10pm) minimum surface depth treatment recommended for normal weather exposure. 215-R1 (Aluminum Association Code AA-C22A41) provides 0.7 mils (18pm) minimum surface depth recommended for severely corrosive and abrasive atmospheric exposure. Both finish types available only on aluminum. Louvers shall receive a 204-R1 clear anodize finish complying with Aluminum Association Code-C22A31. Finish is applied to chemically etched and pretreated aluminum to 0.4 mils (10pm) minimum surface depth by a 30 minute anodizing process. Louvers shall receive a 215-R1 clear anodize finish complying with Aluminum Association Code AA-C22A41. Finish is applied to chemically etched and pretreated aluminum to 0.7 mils (18pm) minimum surface depth by a 60 minute anodizing process. Dimensions in parentheses () indicate microns. Shernar 5000 is registered trademark of Sherwin-Willians. *AAMA 2605-13 is the most stringent performance specification for organic coatings or exterior aluminum finishes in the industry, requiring 10 years south Florida exposure. t AAMA 2604-13 supersedes AAMA 2604-10 and requires 5 years of south Florida exposure. *RUSKIN'S 50% PVDF fluoropolymer, 70% PVDF fluoropolymer based finishes (Pearledize 50 and Pearledize 70) and prime coat finishes are provided by Sherwin-Williams. Twenty-year warranties are only available an extruded aluminum products, and are subject to restrictions. Consult RUSKIN for additional information. FIN-417/replaces FIN -416 &RUSKIN AUTHORITY IN AIR CONTROL PROUDLY FINISHED WITH SHERWIN-WILLIAMS. Ei"%ll'IS:TRUCTURAL %NGtNu nNG Structural Calculations For: Impact Public School Rooftop Mechanical Support 3438 South 148th Street Tukwila, WA 98168 Prepared for: NAC Architecture Job #: 02372-2017-01 Date: December 15, 2017 REVIEWED OR CODE CO�PLIANCE ROVED JUN 21 2018 BUILDING Dila VISION RECEIVED CITY OF TUKWILA tT 3 2 20,3 PERMIT CENTER SEATTLE 2124 Third Ave, Suite 100, Seattle, WA 98121 TACOMA 934 Broadway, Suite 100, Tacoma, WA 98402 O 206.443.6212 ssfengineers.com 0 253.284.9470 Seismic Design Loads (ASCE 7-10) Importance Factor 1 as, = 1 ?,= 1.5 z = 5.5 h = 35 Ss= 1.365 Fa = 1 Sips= 0.91 13.1.3 Table 13.6-1 Table 13.6-1 Ht of Supported Unit Avg Roof Ht ASCE 7-10 Maps or the USGS Website (http://eghazmaps.usgs.gov/) Table 11.4-1 Weight of Unit = 675 Ibs Seismic Demand = 215 Ibs Wind Loads V = 25psf A = 6.5' x 4' = 26 sq. ft Fw = 650# STRUCTURAL ENGINEERING 2124 Third Avenue . Suite 100 . Seattle . WA 98121 w40w. swen son sayfaget. com Office: 206.443.6212 Fax: 206.443.4870 Wind Loads Za35 = 695# (1) A35 ea. elevation min. Date: Project #: Design: Sheet: 6/11/2018 ZFK 0 U 113 3 • l flirc 4) LS) 04 STRUCTURAL ENGINEERING 2124 Third Avenue - Suite too - Seattle, WA 98121 p: 206.443.6212 ssfengineers.com Copyright 2015 Swenson Say Faget - All Rights Reserved 6x6 DF#1 TYP. cc • ---, I— t w �0 CL W o Lv a OZ - v cCt hi O z • ►�1 %Q`1= 1 I�` Project Title: Impact PS N V V N • "4 o Date/11 /13 Design zfk Sheet Title: Drown Rooftop Heat Pump Support zfk SSF project no. Sheet `HERMIT COORD COPY cJ PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M18-0072 DATE: 06/15/18 PROJECT NAME: IMPACT PUBLIC SCHOOL SITE ADDRESS: 3438 S 148TH ST X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS• k3 Ci Building Division Public Works n ire Prevention Structural ia\IL6 Planning Division P1 Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 06/19/18 Structural Review Required REVIEWER'S INITIALS: DATE: n APPROVALS OR CORRECTIONS: DUE DATE: 01117/18 Approved ❑ Approved with Conditions Corrections Required ❑ Denied n (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire ❑ Ping 0 PW ❑ Staff Initials: 12/18/2013 UNIVERSAL REFRIGERATION INC, Home Espanol Contact Safety & Health Claims & Insurance Washington State Department of `, Labor & Industries Search L&I Page 1 of 2 A -Z. Index help My t &I Workplace Rights Trades & Licensing UNIVERSAL REFRIGERATION INC Owner or tradesperson Principals GATES, CHRISTOPHER A, PRESIDENT GALVIN, BRYAN S, VICE PRESIDENT GATES, CHRIS A, AGENT VERNON, GUY E (End: 01/01/1980) JACKSON, SHELDON G (End: 01/01/1980) OSENBAUGH, CHARLES R (End: 01/01/1980) RAEDER, STEVEN C, PRESIDENT (End: 03/29/2012) Doing business as UNIVERSAL REFRIGERATION INC WA UBI No. 600 599 723 PO BOX 614 AUBURN, WA 98071-0614 253-939-5501 KING County Business type Corporation Governing persons BRYAN GALVIN CHRIS GATES; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties COMMERCIAUINDUSTRIAL/REFRIG License no. UNIVERI159RF Effective — expiration 12/06/1985— 04/01/2020 Bond AMERICAN STATES INS CO Bond account no. EX903622 Active. Meets current requirements. $6,000.00 Received by L&I Effective date 03/18/2002 12/06/2001 Expiration date Until Canceled Insurance Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=600599723&LIC=UNIVERI159RF&SAW= 6/27/2018 UNIVERSAL REFRIGERATI©N INC Ohio Cas Ins Co Policy no. BK053333383 $1,000,000.00 Received by L&I Effective date 03/19/2018 04/01/2017 Expiration date 04/01/2019 Insurance history Savings .................. No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations ........._.........._...... No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID 469,068-01 Doing business as UNIVERSAL REFRIGERATION INC Estimated workers reported Quarter 1 of Year 2018 "31 to 50 Workers" L&I account contact T5 / MELISSA VEST (360)902-5613 - Email: VESM235@Ini.wa.gov Account is current. Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 04/09/2014 Inspection no. 316993518 Location 6742 185th Ave NE Redmond, WA 98052 Violations Page 2 of 2 Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https://secure. lni.wa.gov/verify/Detail.aspx?UBI=600599723&LIC=UNIVERI159RF&SAW= 6/27/2018