Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M18-0080 - RPI - CARRIER RTU REPLACEMENT
RPI 3325 S 116TH ST BLDG 2 EXPIRED 01/05/19 MI 8-0080 Parcel No: Address: \ City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.eov 0923049068 3325 S 116TH ST BLDG 2 Project Name: RPI MECHANICAL PERMIT Permit Number: Issue Date: Permit Expires On: M18-0080 7/10/2018 1/6/2019 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: EPROPERTY TAX INC DEPT 207 PO BOX 4900 , SCOTTSDALE, WA, 85261 KELLY PARFITT 899 W MAIN ST, AUBURN, WA, 98001 IECS INC (CONSTRUCTION) PO BOX 19252 , SEATTLE, WA, 98109- 1252 IECS***044QL Phone: (253) 939-9495 Phone: (206) 939-9495 Expiration Date: 11/20/2018 DESCRIPTION OF WORK: REPLACE EXISTING CARRIER #13, #16 AND #22 WITH NEW CARRIER RTU'S OF LIKE SIZE Valuation of Work: $30,000.00 Type of Work: REPLACEMENT Fuel type: GAS Fees Collected: $597.26 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: TUKWILA Sewer District: VALLEY VIEW Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: Date: 2017 2017 2017 2015 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: 6 S Print Name: �1�( k pe - Date: 07-1(D-1 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 4: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 8: ***MECHANICAL PERMIT CONDITIONS*** 9: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 10: Manufacturers installation instructions shall be available on the job site at the time of inspection. 11: The attached set of mechanical plans have been reviewed by The Tukwila Fire Marshals Office and are acceptable with the following concerns: 12: H.V.A.C. units rated at greater than 2,000 cfm require auto -shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2437) 13: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air -moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 14: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2437) 15: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2437) 16: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 17: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 18: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 19: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 20: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1400 FIRE FINAL 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0705 REFRIGERATION EQUIP 0701 ROUGH-IN MECHANICAL 0702 SMOKE DETECTOR TEST CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov \ Mechanical Permit No. Project No. M(f-ao Date Application Accepted: Date Application Expires: (9-(6 (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address: 3325 S. 116th St. Tenant Name: RPI King Co Assessor's Tax No.: PROPERTY OWNER Name: EPROPERTY TAX INC DEPT 207 13060d Address: PO Box 4900 City: Scottsdale State: AZ Zip: 85261 CONTACT PERSON — person receiving all project communication Name: Kelly Parfitt Address: 899 W. Main St. City: Auburn State: WA Zip: 98001 Phone: 253-939-9495 Fax: 253-939-9628 Email: kellyp@seattlemechanical.com 0923049068 Suite Number: Bldg. 2 Floor: New Tenant: ❑ Yes ® ..No MECHANICAL CONTRACTOR INFORMATION Company Name: Seattle Mechanical Inc Address: 899 W. Main St. City: Auburn State: WA Zip: 98001 Phone: 253-939-9495 Fax: 253-939-9628 Contr Reg No.: IECS'**044QL Exp Date: 11/20/18 Tukwila Business License No.: BUS 0992961 Valuation of project (contractor's bid price): $ 30,000.00 Describe the scope of work in detail: Replace Existing Carrier RTU #13, #16, #22 with new Carrier RTU's of like size. Use: Residential: New 0 Replacement ❑ Commercial: New ❑ Replacement Fuel Type: Electric 0 Gas J Other: H:\Applications\Forms-Applications On Line \2016 Applications\Mechanical Permit Application Revised 1-4-16.docx Revised: January 2016 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Residential, Nighttime Furnace >100k btu Industrial Floor furnace 55 dB(A) Suspended/wall/floor mounted heater 57 dB(A) Appliance vent Commercial Repair or addition to heat/refrig/cooling system 47 dB(A) Air handling unit 65 dB(A) <10,000 cfin 3 Unit Type Qty Air handling unit Residential, Nighttime >10,000 cfm Industrial Evaporator cooler 55 dB(A) Ventilation fan connected to single duct 57 dB(A) Ventilation system Commercial Hood and duct 47 dB(A) Incinerator — domestic 65 dB(A) Incinerator — comm/industrial 60 dB(A) Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 *DaytimC means 7AM-IOPM, Monday through Fnday and 8AM-10PM, Saturday, Sunday and State -recognized holidays. District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) A few sounds are exempt from the noise code, including: • Warning devices; • Construction and property maintenance during the daytime hours (lam -1 Opm); • Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING _WN AIJ O lY r ENT: Signature: "` Date: 6/18/2018 Print Name: Kelly Parfitt Day Telephone: 206-255-0045 Mailing Address: 899 W. Main St Auburn WA 98001 City H:Wpplications\Forms-Applications On Line\2016 Applications\M chanical Permit Application Revised 1-4-16.docx Revised: January 2016 bh State Zip Page 2 of 2 / `. / 4 ash Register Receipt City of Tukwila Receipt$ Number 190 R14891 DESCRIPTIONS ACCOUNT QUANTITY PermitTRAK PAID $482.40 M18-0080 Address: 3325 S 116TH ST BLDG 2 Apn: 0923049068 $482.40 MECHANICAL $459.43 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $426.28 TECHNOLOGY FEE $22.97 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R14891 R000.322.900.04.00 0.00 ". $22.97 $482.40 Date Paid: Tuesday, July 10, 2018 Paid By: SEATTLE MECHANICAL Pay Method: CHECK 14151 Printed: Tuesday, July 10, 2018 9:21 AM 1 of 1 %l i SYSTEMS Cash Register Receipt City of Tukwila Receipt Number R14746 DESCRIPTIONS ACCOUNT QUANTITY PAID $114.86 $114.86 $114.86 $114.86 $114.86 PermitTRAK M18-0080 Address: 3325 S 116TH ST BLDG 2 Apn: 0923049068 MECHANICAL PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R14746 R000.322.102.00.00 0.00 Date Paid: Tuesday, June 19, 2018 Paid By: SEATTLE MECHANICAL Pay Method: CHECK 14027 Printed: Tuesday, June 19, 2018 10:38 AM 1 of 1 rfTri SYSTEMS FILE COPY Permit Rice M 1 8 - oo go Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Cop onditio -is acknowledged: By: 7:11S. Date: 07'lO-lR City of Tukwila BUILDING DIVISION 1 SFFAR, \TF: PERMIT r: UIRfD FOR: 0 Mechanical Iii i-lectncal gePlumbing ?Gas Piping City of Tukwila lil`i_:r"" G DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of ' uks'rila G' +'d!ng Division. NOTE: Revisions will require a new plan submittal ! and may include additional plan review fees. I JAN 05 2019 No, 00 80 REVIEWED FOR CODE COMPLIANCE APPROVED A-SJULO3'018 WIC CDING DIof VISION ISION REPLACE RTU # 22 CARRIER 48DJE004600 WITH A NEW CARRIER 48KCEA04A2A6. 9 r. r p' ITO r REPLACE RTU # 13 CARRIER 50DJ007610 WITH A C NEW CARRIER 48LCE007A1A6. at 1� tis Iles lifts - ir ,..., ...-::!... 2 F' {,; 1 ti i '`. I f se a el ell REPLACE RTU # 16 CARRIER 48DJD006620 WITH A NEW CARRIER 48KCDA06A2A6. ra 'ERM IT SST' Go gOe Earth feet meters JARS 05 2019 A APPROVED 100 JUL 03 2018 ;' X118 -00 9Q• City of Tukwila BUILDING DIVISION PATE: 76.(7'« t 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 Mechanical Summary 2015 Washington State Energy Code Compliance MECH-SUM Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised January 2017 Project Information Project Title: Gateway North Bldg. 2 - RPI Date 6/18/2018 Applicant Information. Provide contact information for individual who can respond to inquiries about compliance form information provided. For Building Dept. Use Company Name: Seattle Mechanical Inc Company Address: 899 W. Main St. Aubum, WA 98001 _ Applicant Name: f T b FOR ✓ No S stem Changes COD Applicant Phone: 253-939-9495 COD f �+0���/LIAf�CE�© ❑New Building ❑Building Addition ❑Tenant Improvem. t [Syst( em lront JUL10 J city of Tukwila BUIL 4� DINC OI�ISI Project Description Briefly describe mechanical systems in the text box provided 2018 • , Total Bldg Performance (TBP) This path includes all mandatory provisions per C401.2 Option 2. MECH-SUM, MECH-CHK, and C407 Energy Analysis forms required. Design Load Calculations ❑ Load calculation summary ❑ MECH-LOAD-CALC Form Provide design load calculations for all mechanical systems and equipment serving the building heating, cooling or ventilating needs. If a load calculation summary is provided with the permit documents that includes all applicable compliance information then the MECH-LOAD-CALC form is not required. Mechanical Schedules ❑ Mechanical Plans ❑ MECH-EQ Forms (TBD) Indicate location of equipment compliance information. If provided on plans then MECH-EQ forms are not required, however, include on plans all applicable compliance information listed in MECH-EQ tables. Dedicated Outdoor Air System Requirements and High Efficiency VAV Alternate ❑ DOAS is required per C403.6 effective July 1, 2017 (office, retail, education, library and All occupied, conditioned areas shall be served by a DOAS that delivers required ventilation not require space conditioning fan operation. Space conditioning fans cycled off when no ❑ Ventilation provided via natural ventilation per 2015 IMC in lieu of DOAS (C403.6, fire station occupancies) air in a manner that does heating or cooling is required. Exception 1) of DOAS (C403.6, Exception library or fire station) C402.4.1.4 with 100% of I Ventilation and space conditioning provided by a HEVAV system per C403.7 in lieu 2) ❑ DOAS included in project, although not required (occupancy not office, retail, education, ❑ DOAS related allowances included in project: ❑ Prescriptive vertical fenestration maximum area allowance increased to 40% per conditioned floor area in building served by DOAS. ❑ Exception to air economizer per C403.3 Exception 1, include MECH-ECONO form. Fan Power exceeds 5hp. 5 horsepower threshold. .1 Project includes HVAC air distribution systems that provide heating and/or cooling If yes, provide a MECH-FANSYS -SUM form. ❑ For one or more systems, the total fan motor nameplate hp of all fans in HVAC system If yes, provide a seperate MECH-FANSYS form for each HVAC system exceeding the Refer to Section C403.2.11 and MECH-FANSYS-DOC for requirements and exceptions. HVAC Hydronic Systems systems ❑ Hydronic chilled water • Water -loop heat pump '1 No hydronic ❑ Hydronic heating water ❑ Geothermal C406 Additional Efficiency Options - Mechanical ❑ C406.2 More efficient HVAC equipment and fan systems Requires 90% of heating and cooling capacity to be equipment listed in tables C403.2.3(1)-(9) pumps and heat recovery chillers. All equipment listed in tables C403.2.3(1)-(7) must minimum requirements. All stand alone supply, retum, and exhaust fans over 1hp must selected within 10% of maximum total or static pressure. or air -to -water heat be 15% more efficient than have FEQ z 71 and must be required ventilation air in a `' a� 9! use be OF TUK . ILA Si C406.6 Dedicated outdoor air system (DOAS) Requires 90% of conditioned floor area to be served by a DOAS per C403.6 that delivers manner that does not require space conditioning fan operation. ❑ C406.7 Reduced energy in service water heating Requires 90% of floor area be in occupancy types listed in C406.7.1 and that 60% of provided by heat pump, waste heat recovery or solar water -heating systems. CITY MI9-OO9a JUN 092018 PER C u 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 Mechanical Summary, pg. 2 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 MECH-SUM Revised January 2017 Service Water Heating Systems Equipment Type (s) ❑ Hot water heating tank(s) ❑ Instantaneous Dedicated boiler ❑ Heat exchange from space heat boiler or central hot water/steam Distribution Type (s) ❑ Circulation System ❑ On -demand water systems ✓ No service Conunissioning Commissioning is required ❑ Mechanical systems If required, commissioning Exceptions to commissioning for: per C408.2 ❑ Service water heating systems per C408.4 shall be performed for all applicable systems regardless of individual equipment capacity. requirements: of all mechanical space conditioning systems in the building do not exceed 240,000 Btu/h heating. Mechanical systems commissioning not required. water heating system in building does not exceed 200,000 Btu/h. Service water heating not required. ,, Total output capacity cooling or 300,000 Btu/h • Capacity of largest service systems commissioning Low Energy and Semi -Heated Spaces (Note 6 and 7) Space Type Location in Plan(s) Space(s) Served Area Served, square feet Heating Capacity, Btu/h (Note 4) Cooling Capacity, Btu/h (Note 5) Peak Space Conditioning Capacity, Btu/h-sf Compliance Check Notes Note 4 - Provide total installed heating output capacity of systems serving Low Energy or Semi -Heated space(s) in btuh. Note 5 - Provide total installed cooling capacity of system serving Low Energy space(s) in Btu/h. Not allowed for semi -heated spaces. En er 0 if no cooling. Note 6 - Refer to Section C402.1.1 Low Energy Building. Intalled peak space conditioning capacity, heating or cooling, may not exceed 3.4 Btu/h'sf. Note 7 - Refer to Section C402.1.1.1 and Semi -Heated Space definition in Chapter 2. Total heating output capacity may not exceed 8 Btu/h*sf. Only systems without electric resistance heating and no cooling are eligible for the wall insulation exception under semi -heated. 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 - Page 1 of 7 Mechanical Permit Plans Checklist MECH-CHK 2015 Washington State Energy Code Compliance Fors for Commercial Buildings including R2 & R3 over 3 stories and all R1 ProjectTitle: Gateway North Bldg. 2 - RPI Date 6/18/2018 The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the Washington State Energy Code, Commercial Provisions. Applicable (yes,no,na) Code Section Code Provision Information Required - Must be in permit documents Location in Documents Building Department Notes Equipment - Sizing, Performance and Type NA C403.1 Exempt process equipment Identify equipment to be used in manufacturing, industrial or commercial processes that do not provide space conditioning; identify provisions applicable to this equipment per C403.1 exception NA C403.2.1 Load calculations Provide load calculations performed per ASHRAE Std 183 or equivalent, using design parameters per C302 and Appendix C; include load adjustments to account for energy recovery Yes C403.2.2 Equipment and system sizing Indicate that output capacities of heating and cooling equipment and systems are no greater than the smallest available equipment size that exceeds the calculated loads; note exceptions taken Yes 0403.2.3 0403.2.3.2 0403.2.13.1 HVAC equipment performance requirements (efficiency) Provide equipment schedules on plans or complete MECH-EQ forms indicating type, capacity, rated and WSEC minimum efficiencies for all heating and cooling equipment; include supply and OSA cfms and operating hours for all air systems; identify heating and cooling equipment that does not have a corresponding WSEC minimum efficiency (manufacturer rated) Yes 0405.8 0403.2.14 Electric motor efficiency List all motors >_ 1/12 hp (that are not integral to a rated piece of equipment) in the mechanical or electrical equipment schedules on plans; indicate hp, rpm, number of poles and rated efficiency, or exception applied For fractional hp motors (1/12 - 1 hp), indicate whether they are an electronically commutated motor, have rated efficiency of at least 70%, or exception taken Yes C403.2.11.1 Fan power limitation For all HVAC fan systems that provide heating and / or cooling, provide system total nameplate hp in MECH-FANSYS-SUM form For all applicable HVAC systems with total fan motor hp > 5hp, verify fan system motor hp or bhp complies with fan power limits per equations in Table C403.2.11.1(1), provide MECH- FANSYS form for each system Yes 0403.2.11.2 Motor nameplate hp For all applicable HVAC systems with total fan motor hp > 5hp, indicate fan motors specified are the smallest available motor hp size greater than fan bhp, note exceptions taken Yes 0403.2.11.3 Fan efficiency For all applicable HVAC systems with total fan motor hp > 5hp, identify in equipment schedule all fans required to comply with fan efficiency grade and indicate rated FEG is z 67, or exception taken; indicate these fans are sized so total efficiency is within 15% of the fan maximum total efficiency NA 0403.2.11.4 Group R occupancy exhaust fan efficacy For all exhaust fans < 400 cfm in Group R occupancies, indicate in equipment schedule the fan flow rate and efficacy (cfm/watt), or exception taken; refer to Table C403.2.11.4 (CE -57) NA C403.2.13 Variable flow capacity - fans For fan motors a 7.5 hp, indicate method of variable flow control (VSD or equivalent method) in equipment schedule, or exception taken; for equivalent method for an HVAC system refer to HVAC System Controls for additional requirements NA 0403.2.3 Maximum air cooled chiller capacity For chilled water plants and buildings with > 500 tons of cooling capacity, indicate air-cooled chiller capacity is 5 100 tons, or exception taken NA C403.4 Large capacity cooling systems For buildings with z 300 tons of cooling capacity, indicate method of multi -stage or variable capacity control (VSD, multiple staged compressors, or max capacity of any single unit < 66% of the total) NA C403.2.3.1 Non-standard water-cooled centrifugal chillers For water-cooled centrifugal chillers not designed for operation at standard conditions, provide calculations documenting maximum full load and part load rated equipment performance requirements NA C403.2.13.1 C403.4.3.2 Centrifugal fan open -circuit cooling towers For open -circuit centrifugal fan cooling towers with >_ 1,100 gpm capacity, indicate cooling towers comply with efficiency requirements for axial fan open circuit cooling towers NA C403.4.2 C403.4.2.5 Large capacity boiler systems For single boilers with > 500,000 Btu/h capacity, indicate multi -stage or modulating bumer For boiler system (single or multiple) with > 1,000,000 Btu/h capacity, indicate tumdown ratio per Table C403.4.2.5 and method (multiple single input boilers, modulating boilers, or combination) NA C403.2.13 Variable flow capacity - pumps For pump motors a 7.5 hp, indicate method of variable flow control (VSD or equivalent method) in equipment schedule, or exception taken; for equivalent method for a hydronic system refer to Hydronic System Controls for additional requirements NA C403.2.3 Gas and oil -fired forced air fumace and unit heaters For forced air fumaces with capacity z 225,000 Btu/h and all unit heaters, indicate in equipment schedule intermittent ignition or IID, flue or draft damper, and rated jacket loss NA C403.2.4.8 Combustion heating equipment For combustion heating equipment with output capacity > 225,000 Btu/h, indicate modulating or staged combustion control NA C403.2.3.3 Packaged electric heating / cooling equipment Verify all packaged electric equipment with > 6,000 Btu/h cooling capacity and any amount of heating is a heat pump; include in equipment schedules NA 0403.2.12 Heating outside a building Indicate systems providing heating in non -enclosed outdoor occupied spaces are radiant systems; refer to HVAC System Controls for additional requirements NA C403.2.7.1 Kitchen exhaust hoods Indicate on plans the type, duty and exhaust air rate of each kitchen hood, refer to HVAC System Controls for additional requirements Yes C403.2.4.3 Outdoor supply air, exhaust and relief dampers Indicate locations of OSA intake, and exhaust and relief outlet dampers on plans; indicate whether dampers are Class 1 motorized, or gravity and exception taken (include leakage rating, cfm/sf); refer to HVAC System Controls for additional requirements for OSA dampers Yes C403.2.4.3 Retum air dampers Indicate locations of retum air dampers that are integral to economizer operation; verify dampers are motorized; indicate whether dampers are Class 1, or within packaged equipment eligible for leakage rating exception (include leakage rating, cfm/sf) 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 - Page 2 of 7 Mechanical Permit Plans Checklist 2015 Washington State Energy Code Compliance F MECH-CHK Project Title: Gateway North Btdg. 2 - RPI rcevisea January 2017 Date 6/18/2018 The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the Washington State Energy Code, Commercial Provisions. Applicable (yes,no,na) Code Section Code ProvisionInformation Required -Must be in permit documents Location in Documents Building Department Notes NA C403.2.4.3 Stairway and shaft vent dampers Indicate location of stairway and shaft vent dampers on plans; verify dampers are Class 1 motorized; refer to HVAC System Controls for additional requirements NA0403.2.4.4 Zone isolation dampers For systems serving areas > 25,000 sf or spanning more than one floor, that include areas that are expected to be occupied non -simultaneously; identify isolation zone areas on plans and locations of associated isolation dampers in HVAC distribution system; refer to HVAC System Controls for additional requirements NA C403.2.3.4 Humidification For cooling systems with humidification equipment that are also required to have air economizer, indicate humidifier is adiabatic (direct evaporative or fog atomization), or exception taken Additional Efficiency Package Option, More Efficient HVAC Equipment & Fan Performance - Must comply with all 3 provisions to be eligible NA C406.2.1 C403.2.3 HVAC system selection To comply with additional efficiency package option, calculate the percentage of heating and cooling equipment in the project (based on output capacity) that do not have a corresponding WSEC listed efficiency; shall be less than 10% to comply NA C406.2.2 C403.2.3 Minimum equipment efficiency To comply with additional efficiency package option, indicate that all listed heating and cooling equipment have a rated efficiency that exceeds WSEC listed efficiency by at least 15% NA C406.2.3 C403.2.11.3 Minimum fan efficiency To comply with additional efficiency package option, indicate rated FEG of stand abne fans is z 71; indicate these fans are sized so the fan efficiency at design conditions is within 10% of the maximum total or static efficiency HVAC System Controls Indicate locations of thermostatic and humidity control devices and the zones they serve on plans, including perimeter system zones NA C403.2.4.1 Thermostatic controls (thermostats and humidistats) Where adjacent (neighboring) zones are controlled by separate thermostats (including perimeter systems used to offset heat gain or loss), and are connected by permanent openings > 10% of either zone sf area, indicate controls configured to prevent adjacent zones from operating in conflicting modes (one in heat, other in cool); applies to adjacent perimeter zones, adjacent nonperimeter zones, and adjacent perimeter and nonperimeter zones If applying Exception 2 to nonperimeter zones adjacent to perimeter zones, indicate that setpoints and deadband settings in these zones are coordinated so cooling in a nonperimeter zone does not occur until the temperature in that zone is 5°F higher than the adjacent perimeter zone temperature in heating NA C403.2.4.1.1 Heat pump supplementary heat Indicate staged heating operation with compression as the first stage of heating and supplemental heating controlled with outdoor lock -out temperature set to 40°F or less Yes C403.2.4.1.2 Deadband Indicate zone thermostatic controls configured with 5°F minimum deadband for systems that control both heating and cooling C403.2.4.1.3 Setpoint overlap restriction (thermostats) If separate heating and cooling systems with separate thermostatic control devices are used to serve a zone, indicate locations of both thermostatic control devices and the zone they serve on plans Indicate a limit switch, mechanical stop or DDC control with programming to prevent simultaneous heating and cooling C403.2.4.2 C403.2.4.2.1 C403.2.4.2.2 Automatic setback and shutdown Indicate zone thermostatic controls configured with required automatic setback and manual override functions, setback temperatures, and control method (automatic time clock or programmable controls); note exceptions taken C403.2.4.2.3 Automatic (optimum) start Indicate system controls that adjust equipment start time required to bring each area served up to design temperature just prior to scheduled occupancy C403.2.4.3 Outdoor supply air dampers Indicate automatic controls configured to close OSA damper during unoccupied equipment operation; not including economizer cooling, night flush or IMC required OSA / exhaust NA C403.2.4.3 Stairway and shaft vent dampers Indicate method of activation of stairway and shaft vent dampers (fire alarm or interruption of power) NA C403.2.4.4 Zone isolation controls For systems serving areas > 25,000 sf or spanning more than one floor, that include areas that are expected to be occupied non -simultaneously; indicate controls that allow for independent space conditioning of isolation zones; or exception taken NA0403.2.12 Heating outside a building Indicate occupancy sensing or timer switch controls configured to automatically shut off heating system when area served is unoccupied NA0403.2.4.5 Snow melt systems Indicate automatic controls configured to shut off system when pavement temperature exceeds 50°F and no precipitation is falling, and when outdoor air temperature exceeds 40°F NA C403.2.4.6 Freeze protection system controls Indicate automatic controls to shut off system when outdoor temperature exceeds 40°F, or conditions protect fluid from freezing NA C403.2.4.9 Group R1 hotel / motel guest rooms For hotels and motels with over 50 guest rooms, indicate automatic controls serving guest rooms that are capable of setback (heating) and set-up (cooling) of temperature setpoint by at least 5°F; indicate control method - activated by room entry or occupancy sensor 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 - Page 3 of 7 Mechanical Permit Plans Checklist MECH-CHK 2015 Washington State Energy Code Compliance Forms for Commercial .,__ _ .._ _._. - __-..---..-.-..... ,NG v,JOU JOI IUGIy cv 11 Project Title: Gateway North Bldg. 2 - RPI (Date 6/18/2018 The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the Washington State Energy Code, Commercial Provisions. Applicable (yes,no,na) Code Section Code ProvisionInformation Required -Must be in permit documents Location in Documents Building Department Notes NA C403.2.4.10 C403.2.4.11 Group R2 / R3 dwelling units, Group R2 sleeping units For primary space conditioning system, indicate 5-2 programmable thermostats capable of two setback periods per day; for all thermostats indicate purpose (heating only, cooling only, or both), required temperature range and at minimum a 10°F deadband; or exception taken NA C403.2.6 C403.2.11.4 Ventilation Indicate method of ventilation air delivery (natural or mechanical) for each zone If mechanically delivered, indicate that systems are configured to provide not more than 150% of, but at least the minimum required volume of outdoor air to each zone per IMC, ASHRAE 62.1 or other applicable code (WAC, OSHA, etc); or exception taken If delivered via natural ventilation, identify required elements per IMC including minimum openable area to the outdoors or qualifying adjoining spaces NA C403.2.6.2 Demand controlled ventilation Identify spaces > 500 sf with occupant load > 25 people/1,000 sf per IMC; for each space indicate whether it is served by an HVAC system with total design OSA > 3,000 cfm, and / or the system has airside economizer or automatic modulating OSA damper; indicate OSA controls are configured to provide demand controlled ventilation or provide supporting documentation for applied exception NA C403.2.6.3 Occupancy sensors For gyms, classrooms, auditoriums and conference rooms > 500 sf, indicate occupancy -based OSA control when space is unoccupied and method (closes OSA damper or shuts -off equipment); or altemate means provided to automatically reduce OSA when space is partially occupied NA C403.2.6.4 C403.2.6.4.1 Enclosed loading dock ventilation For enclosed loading docks, indicate ventilation / exhaust system method of activation (gas detection system for CO and NO2, or occupancy sensors), and control method (staged or modulating) NA C403.2.6.4 C403.2.6.4.2 Enclosed parking garage ventilation For enclosed parking garages, indicate ventilation / exhaust system activated by gas detection system for CO and NO2, and control method (staged or modulating); or exception taken NA C403.2.7.1 Kitchen exhaust hoods Provide calculations that show a balanced accounting of total kitchen exhaust (include all hoods) with % of: supply air, transfer air from adjacent spaces, and make-up air; if applicable, indicate that direct make-up air to each hood does not exceed 10% of hood exhaust For kitchens with total hood exhaust exceeding 2,000 cfm, indicate exhaust air rate per Table C403.2.7.1 and compliance method (DCV, energy recovery, or transfer air that would otherwise be exhausted) NA C403.2.7.2 Laboratory exhaust systems Refer to Systems Requiring Energy Recovery for requirements NA C403.2.13 Variable flow capacity - HVAC system fans For HVAC fan motors z 7.5 hp, indicate method of variable flow control (VSD, or equivalent control method that reduces design air volume by 50% at 1/3 static design pressure); note exception taken NA C403.3.1 DX air handler variable cooling control (Under Integrated Economizer) For DX air handlers with economizer and cooling capacity z 65,000 Btu/h, indicate number of cooling stages provided and method (multiple compressors and / or variable speed compressors); indicate minimum displacement (capacity reduction) as % of full load Indicate control method (cooling capacity controlled in response to space temperature, space temperature controlled by modulating supply airflow, or both) NA C403.2.11.5 Fan airflow control For DX air handling units with cooling capacity z 65,000 Btu/h and evaporative and chilled water air handling units with fan 2 0.25 hp, indicate whether system is single zone or multiple zone and related control method (cooling capacity controlled in response to space temperature, space temperature is controlled by modulating supply airflow, or both) For mechanical cooling systems (includes DX and chilled water coils) that control cooling capacity in response to space temperature - Provide a minimum of two stages of fan control; indicate minimum fan speed is <_ 66% of full speed drawing S 40% of full speed fan power during periods of low cooling or ventilation only For other mechanical cooling systems (includes DX and chilled water coils) that control space temperature by modulating airflow (in lieu of, or in addition to, controlling capacity in response to space temperature) - Provide fan controls for modulating supply airflow; indicate minimum fan speed is 5 50% of full speed drawing 5 30% of full speed fan power during periods of low cooling or ventilation only; or exception taken NA C403.2.4.12 DDC system capabilities Provide central and zone level DDC controls as required based on system application, capacity or size thresholds and other qualification per Table C403.2.4.12.1 Identify all DDC system input / output control points; indicate capability for trending and graphical display Ducting Systems NA C403.2.8.1 C403.2.8.3 Duct construction Indicate on plans that all ductwork is constructed and sealed per IMC For OSA ductwork, also indicate on plans that ductwork meets air leakage requirements per C402.5 and vapor retarder requirements per the IBC NA C403.2.8.3 Duct pressure classifications Identify location of low, medium and high pressure ductwork on plans NA C403.2.8.3.3 High pressure duct leakage test Indicate high pressure duct leakage testing requirements on plans; provide test results to jurisdiction when completed 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 - Page 4 of 7 Mechanical Permit Plans Checklist MECH-CHK 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 8 R3 over Project Title: Gateway North Bldg. 2 - RPI Date 6/18/2018 The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the Washington State Energy Code, Commercial Provisions. Applicable (yes,no,na) Code Section Code Provision Information Required - Must be in permit documents Location in Documents Building Department Notes NA C403.2.8.1 C403.2.8.2 Duct insulation For supply and retum ductwork located in unconditioned space or outdoors, indicate R -value of insulation on ductwork on plans; identify climate zone; note exceptions taken For supply ductwork located in conditioned space, identify if design supply temperature is < 55°F or> 105°F and indicate R -value of insulation on this ductwork on plans; note exception taken For OSA ductwork, shafts and plenums, indicate R -value of insulation on these elements on plans per Table C402.1.3 for steel -framed walls; note exception taken Piping Systems NA C403.2.9 Piping insulation p g Indicate design temperature range of fluid conveyed in piping and thickness of insulation (in inches) on hydronic piping plans; or exception taken C403.2.9.1 Piping insulation exposed to weather Indicate method of protection of pipe insulation from damage / degradation on hydronic piping plans Economizers C403.3 Air economizer required Identify in equipment schedules on plans or in MECH-EQ forms all cooling systems requiring air economizer controls Provide MECH-ECONO form indicating systems utilizing air economizer exceptions, including those with water -side economizer in lieu of air economizer, indicate on plans eligible exception(s) taken and measures to comply with exception(s) C403.3.1 Integrated economizer operation - air and water Indicate air and water -side economizers are configured for partial cooling operation even where additional mechanical cooling is required to meet the load C403.3.2 Economizer heating system impact - air and water Verify control method of HVAC systems with economizers does not increase building heating energy usage during normal operation Yes C403.3.3.1 Air economizer capacity Indicate modulating OSA and retum air dampers are configured to provide up to 100% OSA for cooling Yes C403.3.1 C403.3.3.2 Integrated air economizer Verify mechanical cooling controls are interlocked with air economizer controls so the outside air damper remains in 100% open position when mechanical cooling is also required to meet the cooling load, until the leaving air temperature is < 45°F For systems with cooling capacity t 65,000 Btu/h, verify that control of economizer dampers is not based only on mixed air temperature; or exception taken NA C403.3.3.3 Air economizer high limit controls Indicate high limit shut-off control method and required high limit per Table C403.3.3.3 NA C403.3.4.1 Water economizer capacity For eligible systems where water -side economizer may be provided in lieu of air economizer, indicate system is capable of 100% design cooling capacity at 50°F db / 45°F wb OSA temperatures NA C403.3.4.2 Water economizer maximum pressure drop Indicate pressure drop across precooling coils and heat exchangers in water economizer system do not exceed pressure drop limit NA C403.3.1 DX air handling equipment control For DX air handlers with economizer and cooling capacity a 65,000 Btu/h, refer to HVAC System Controls for requirements NA C403.2.4.7 DX equipment economizer fault detection and diagnostics For DX air handlers with economizer and cooling capacity z 54,000 Btu/h, provide a fault detection and diagnostics (FDD) system to monitor economizer system operation and report faults Systems Requiring Energy Recovery NAC403.5.1 Energy recovery (ER) - ventilation /exhaust systems For systems with design OSA > 5,000 cfm, or design supply air cfm and % OSA exceeding the values in Tables C403.5.1(1) or (2), indicate exhaust air ER method; or exception taken with supporting calculations For rooms served by multiple systems with aggregate design OSA > 5,000 cfm, or aggregate design supply air cfm and % OSA exceeding the values in Tables C403.5.1(1) or (2), indicate exhaust air ER method; or exception taken with supporting calculations Indicate ER rated effectiveness that increases OSA enthalpy by a 50% based on delta between OSA and retum air enthalpies at design conditions NA C403.2.7.2 Laboratory exhaust systems (energy recovery) For buildings with total lab exhaust > 5,000 cfm, indicate method of energy recovery used to pre -condition laboratory make-up air, ER effectiveness (min 25°F); or altemative method per exception (VAV exhaust, semi -conditioned makeup, or CERM calculation) NA C404.10.4 (under C404.11) Pools and permanent spas exhaust systems (energy recovery) For buildings with pools or spas with water surface area > 200 sf, indicate exhaust air ER method and use of waste heat (preheat ventilation air, pool water or service hot water); or exception taken Indicate ER system has the rated effectiveness and is configured to decrease the exhaust air temperature at design conditions by 2 36°F NA C403.5.2 Energy recovery - steam condensate systems For buildings with on-site steam heating systems, indicate condensate water ER For buildings that use off-site generated steam where condensate is not retumed to the source, indicate on-site condensate water ER 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 - Page 5 of 7 Mechanical Permit Plans Checklist MECH-CHK 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stori Project Title: Gateway North Bldg. 2 - RPI Date 6/18/2018 The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the Washington State Energy Code, Commercial Provisions. Applicable es,no,na (yes,no,na) Code Section Code Provision Information Required - Must be in permit documents Location in Documents Building Department Notes NA C403.5.3 Energy recovery - cooler / freezer condensers For buildings with food service, meat or deli departments that have 2 500,000 Btu/h of remote refrigeration capacity for coolers / freezers, indicate condenser ER and use of captured energy (service water heating, space heating, or dehumidification reheating) For buildings with 2 40,000 sf conditioned floor area and with 2 1,000,000 Btu/h of remote refrigeration capacity for coolers / freezers, indicate condenser ER and use of captured energy for service water heating and also for space heating, or dehumidification reheating NA C403.5.4 Energy recovery - condenser systems For buildings with 24-hour operation and with > 1,500,000 Btu/h of heat rejection capacity and design service hot water load > 250,000 Btu/h, indicate condenser ER to pre -heat service water, or exception taken. Provide calculations showing the amount of recovered heat that is utilized (60% of peak heat rejection load or pre -heat service water to 85°F). Hydronic System Controls NA 0403.2.13 C403.4.2.7 Variable flow control - hydronic system pumps For hydronic system pump motors 2 7.5 hp, indicate method of variable flow control (VSD or equivalent method that requires 2 30% design wattage at 50% design fluid flow); note exception taken Identify whether hydronic coils have DDC controls and associated manner of pump speed control (differential pressure, zone hydronic demand, etc) NA C403.2.5 C403.4.2.4 Hydronic system setback and part load controls For boilers that provide building heating, indicate controls that provide heating water temperature setback based on outdoor temperature For heating and chilled water systems 2 300,000 Btu/h, indicate systems are configured to automatically reset supply water temperature based upon demand; or exception taken. If system pump motor hp 2 3 hp, also indicate controls automatically reduce flow by 2 50%. For chilled water systems (2 300,000 Btu/h, pump motor hp 2 3 hp) that serve water-cooled unitary air conditioners, indicate VSD or staged pumps in chilled water system and heat rejection loop that reduce pump flow so that one control valve is nearly wide open, or to maintain a minimum differential pressure; or exception taken NA C403.4.2 Boiler sequencing Indicate automatic controls that sequence operation of multiple boilers NA C403.4.6 Hot gas bypass limitation For cooling equipment with hot gas bypass, provide either multiple step unloading or continuous capacity modulation; indicate bypass capacity per Table C403.4.6 NA C403.4.2.2 Two -pipe changeover systems Indicate changeover deadband (min 15°F), heating / cooling mode scheduling and changeover temperature range (limit 30°F) NA C403.4.2.6 Chiller / boiler plant pump isolation Indicate controls are configured to automatically reduce overall plant flow and shut-off flow through individual chillers and boilers when not in use NA 0403.2.13.1.1 C403.4.3.1.1 0403.4.3.1.2 Heat rejection equipment - variable flow control For cooling towers with fan motors 2 7.5 hp, indicate VSD and method to adjust fan speed (adjusted based on leaving fluid temperature or condenser temperature / pressure of heat rejection device) _ For multiple -cell heat rejection equipment with VSD, indicate controls that ramp all fans in unison NA C403.4.3.3 Heat rejection equipment - cooling tower flow tumdown Indicate open -circuit cooling towers with multiple pumps or VSD control are designed so all cells can be run in parallel NA C403.4.2.3.1 Water loop heat pump - deadband Indicate capability of central equipment to provide minimum 20°F water supply temperature deadband between heat rejection and heat addition modes; or exception taken NA C403.4.2.3.2.1 Water loop heat pump - heat rejection equipment, Zone 4 Indicate type of cooling tower (open- or closed-circuit) in equipment schedule; indicate method used to limit system heat loss when heat rejection is not needed NA C403.4.2.3.2.2 Water loop heat pump - heat rejection equipment, Zone 5 For open- or closed-circuit cooling towers, provide a heat exchanger that separates the cooling tower and heat pump loop NA C403.4.2.3.3 Water loop heat pump - isolation valves For hydronic heat pump systems with total system power> 10 hp, indicate 2 -way isolation valves on each heat pump and variable flow system control Dedicated Outdoor Air Systems (DOAS) - Optional through 6/30/16, Prescriptive 7/1/2016 C403.6 C403.6.3 Dedicated outdoor,air systems For buildings with office, retail, education, library and fire station spaces, identify these spaces on plans; indicate that ventilation air in each occupied space is provided via a DOAS system; or document compliance with C403.6.3 Impracticality; or exception taken (buildings complying with C402.4.1.4 or C406.6 may not utilize exceptions) C403.6.1 Energy recovery ventilation with DOAS For all DOAS systems, indicate exhaust air ER method; or exception taken with supporting calculations. Indicate ER rated effectiveness that increases OSA enthalpy by >_ 50% based on delta between OSA and retum air enthalpies at design conditions. C403.6.2 Heating / cooling system controls with DOAS Indicate equipment associated with the delivery of zone level heating and cooling (fans, hydronic pumps, primary air dampers, etc) are configured to shut off, and central equipment is configured to tum down, when there is no call for heating or cooling in the zone they serve If applying Exception to heating / cooling fans used for air mixing in the space during deadband periods, include fan watts per cfm in equipment schedule 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 - Page 6 of 7 Mechanical Permit Plans Checklist 2015 Washington State Energy Code Compl• MECH-CHK iance Forms for Commercial Buildings includin R2 & R3 g over StOfres amu an rt i Project Title: Gateway North Bldg. 2 -RP! Revised January 2017 Date 6/18/2018 The following Washington information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the State Energy Code, Commercial Provisions. Applicable (yes,no,na) Code Section Code Provision Information Required - Must be in permit documents Location in Documents Building Department Notes 0402.4.1.4 C403.6 Increased prescriptive maximum vertical fenestration area with DOAS Indicate that all occupied, conditioned spaces are served by a DOAS per C403.6 Additional Efficiency Package Option, Dedicated Outside Air Systems (DOAS) C406.6 Building provided with DOAS To comply with additional efficiency package option, indicate that 90% or more of all occupied, conditioned spaces are served by a DOAS per C403.6 Multiple Zone Air Systems C403.4.4 Air systems serving multiple zones Identify supply air systems serving multiple zones and the zones they serve on plains; indicate whether system is VAV and method of primary air control; or provide supporting documentation for applied exception to VAV Provide equipment schedules on plans or MECH-EQ form that list all VAV air terminals and types 0403.4.4 VAV systems serving multiple zones For each air terminal include: maximum airflow rates for primary supply air during zone peak heating and zone peak cooling; maximum airflow during reheating, recooling or mixing; minimum airflow rate to maintain required ventilation, and the basis for these values; if IMC or ASHRAE 62.1 multiple zone equation is basis for minimum flow rates, provide calculation on plans C403.4.4.1 Single duct VAV terminal units Indicate single duct terminal units are configured to reduce primary supply air before reheating or recooling C403.4.4.2 Dual duct systems - terminal units For systems with separate warm air and cool air ducts, indicate terminal units are configured to reduce the flow from one duct to minimum before mixing with air from the other duct VAV Indicate locations of duct static pressure sensors on plans; include at least one sensor per major duct branch; verify controller setpoint pressure at each sensor is 5 1.2 inch w.g. 0403.4.1.1 0403.4.1.2 system static pressure sensors - sensors and DDC set points For systems with zone level DDC, indicate controls are configured to monitor zone damper positions and reset static pressure setpoint based on the zone requiring most pressure; include control logic that automatically detects and generates an alarm if any zone excessively drives reset logic, and allows building operators to exclude zones from reset logic C403.4.4.3 Multiple -zone VAV system ventilation optimization controls For systems with zone level DDC controls, indicate controls are configured to automatically reduce outdoor airflow in response to changes in system ventilation efficiency; or exception taken C403.4.4.4 VAV system supply air reset Indicate controls automatically reset supply air temperature in response to building loads or outdoor air temperature; or exception taken Multiple Zone HVAC Systems, High Efficiency VAV - Required for systems utilizing C403.6 DOAS Exception 2, must comply with all 16 provisions 0403.7, Item 1 Air economizer Indicate system is configured for 100% air economizer operation and complies with all related economizer requirements per C403.3 (without economizer exceptions) C403.7, Item 2 Direct digital controls (DDC) Provide DDC controls for all components of system; identify all DDC system input / output control points; indicate capability for trending and graphical display C403.7, Item 3 Outdoor airflow measurement and reduction For systems with minimum OSA > 2,500 cfm, indicate outdoor airflow monitoring station that measures OSA intake under all load conditions; indicate control sequence that increases or reduces system OSA cfm based on VAV terminal feedback of ventilation efficiency (per C403.4.4.3 without exceptions) or DCV (per C403.2.6.2) 0403.7, Item 4 Supply airflow measurement For systems with minimum OSA > 2,500 cfm, indicate supply airflow monitoring station capable of measuring supply air delivered to VAV terminals under all load conditions C403.7, Item 5 Zone isolation and maximum area served Verify maximum area served by a single HEVAV system is 5 50,000 sf, or one entire floor, whichever is greater; in addition if a system serves > 25,000 sf, that includes areas that are expected to be occupied non -simultaneously, indicate zone isolation controls per 0403.2.4.4 0403.7, Item 6 Interior / exterior zone design supply air tem erasure P Verify that VAV terminals serving interior cooling driven loads are sized per design supply air temperature that is 5°F higher than VAV terminals serving exterior zones C403.7, Item 7 Maximum air terminal inlet velocity Identify air terminals with minimum primary airflow setpoints > 50% of maximum setpoint in equipment schedule or MECH-EQ form; indicate air terminal inlet velocity does not exceed 900 fpm C403.7, Item 8 Sequence of operation Indicate DDC system sequences of operation are designed and configured per ASHRAE GPC 36 C403.7, Item 9 Maximum allowable system brake horsepower Verify fan system bhp is 5 90% of the bhp limit per Option 2 equation in Table C403.2.11.1(1), provide MECH-FANSYS form for each system C403.7, Item 10 Fan -powered terminal unit motor and control Indicate all series and parallel terminal fans have electronically commutated motors; .ndicate DDC control system is configured to vary air terminal fan speed as a function of the load; indicate fan speed during periods of low heating, low cooling, or ventilation only is s116% of peak design air flow or provide supporting documentation for applied exception 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 - Page 7 of 7 Mechanical Permit Plans Checklist MECH-CHK 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories an Project Title: Gateway North Bldg. 2 - RPI Date 6/18/2018 The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the Washington State Energy Code, Commercial Provisions. Applicable (yes,no,na) Code SectionCode Provision Information Required - Must be in permit documents Location in Documents Building Department Notes C403.7, Item 11 Application of single duct and fan -powered terminal units Indicate VAV terminal types on plans; verify fan -powered terminal units only serve perimeter zones with envelope loads; verify all other zones are served by single duct terminal units C403.7, Item 12 Fan -powered terminal unit primary air reset Indicate DDC controls are configured to automatically reset the primary supply air cfm setpoint of all fan -powered terminal units to the minimum required to maintain ventilation during occupied heating or deadband, based upon the VAV air handling unit OSA ventilation fraction C403.7, Item 13 High occupancy space controls For spaces > 150 sf with occupant density z 25 people / 1000 sf, indicate space is served by a dedicated terminal unit with DCV control that resets terminal unit ventilation setpoint; also indicate occupancy sensor control that automatically reduces minimum ventilation to zero and sets back room heating and cooling setpoints by z 5°F C403.7, Item 14 Dedicated HVAC systems For server, electronic equipment, telecom or similar spaces with cooling loads > 5 W/sf, indicate spaces are served by independent HVAC systems that are separate from HPVAV systems serving rest of building; indicate dedicated HVAC systems have air economizer controls or energy recovery per C403.3 Exception 9 C403.7, Item 15 Central plant efficiency Indicate whether systems are served by a high efficiency heating water plant, or a high efficiency_ chilled water plant If complying via high efficiency heating water plant: Indicate all VAV terminals have hydronic heating coils served by heating water system with either gas-fired boiler(s) with thermal efficiency >_90%, air -to -water heat pumps, or heat recovery chillers If complying via high efficiency chilled water plant: Indicate all VAV air handlers have cooling coils served by chillers with rated IPLV efficiency that exceeds WSEC listed IPLV by at least 25% per Table C403.2.3(7) (note water-cooled IPLV is max, all others are min); indicate smallest chiller or compressor in plant is 5 20% of total plant capacity, or provide thermal storage sized for 5 20% of total plant capacity — C403.7, Item 16 Fault detection and diagnostics Indicate DDC system includes a fault detection and diagnostics (FDD) system configured to monitor operation and provide fault reporting of required parameters for all VAV air handlers and VAV air terminal units in the HPVAV system HVAC Equipment Energy Use Metering NA C409.3.1 HVAC equipment energy use metering For new buildings > 50,000 sf and building additions > 25,000 sf, verify energy use metering of all equipment used to provide space heating and cooling, dehumidification and ventilation will be provided per C409; indicate equipment eligible for exception Documentation and System Specific Requirement To Support Commissioning C408.2 Scope of mechanical systems commissioning Indicate that all mechanical systems, equipment, and controls for which the WSEC requires control functions and / or configuration to perform specific functions are required to be commissioned; For buildings with z 240,000 Btu/h total output cooling capacity or z 300,000 Btu/h total output heating capacity, indicate that all mechanical systems regardless of individual capacity are required to be commissioned; or provide building heating / cooling capacity calculation demonstrating eligibility for exception C403.2.10 C408.1.1 C408.1.2 C408.1.4.2 C103.6 Commissioning requirements in construction documents Indicate in plans and specifications that Cx per C408 is required for all applicable mechanical systems; Include general summary with at a minimum of Items 1 thru 4 of the Cx plan per C408.1.2 including: narrative description of activities, responsibilities of the Cx team, schedule of activities including verification of project close out documentation per C103.6, and conflict of interest plan (if required); Include in general summary that a Cx project report or Compliance Checklist (Figure C408.1.4.2) shall be completed by the Certified Cx Professional and provided to the owner prior to the final mechanical inspection. C408.2.2 Air system and hydronic system balancing Indicate in plans that air and fluid flow rates shall be tested and balanced within the tolerances defined in the specifications; indicate systems shall be balanced in a manner to first minimize throttling losses, then adjusted to meet design flow conditions C408.2.2.1 Air system balancing devices Indicate devices that provide the capability to balance all supply air outlets, zone terminals and air handling equipment requiring system balancing C408.2.2.2 Hydronic system balancing devices Indicate devices that provide the capability to isolate, balance and measure flow across all hydronic equipment requiring system balancing including heating and cooling coils and pumps C408.2.3 Functional performance testing criteria Identify in plans and specifications the intended operation of all equipment and controls during all modes of operation, including interfacing between new and existing -to -remain systems Project Close Out Documentation Yes 0103.6 Documentation and project close out submittal requirements Indicate in plans that project close out documentation and training of building operations personnel is required for all mechanical components, equipment and systems govemed by this code; indicate close out documentation shall include: record documents, O&M manuals, applicable WSEC compliance forms and calculations 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 Economizer Exceptions MECH-ECONO 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised January 2017 Project Title: Gateway North Bldg. 2 - RPI Date 6/18/2018 All cooling systems shall be configured to provide air economizer operation, regardless of system capacity, for new construction and mechanical system alterations. Various exceptions to this requirement are available. Identify all systems that an economizer exception will be applied to and additional information as noted below. For Building Dept. Use Economizer Exception Summary Refer to Section C403.3 for descriptions of economizer provisions and exceptions. For alterations refer to Section C503.4 and Table C503.4. ECONOMIZER EXCEPTIONS - NEW CONSTRUCTION AND ADDITIONS Exp 1 Cooling equipment serving spaces that are provided with a dedicated outdoor air system (DOAS) per C403.6. Spaces served shall have year- round design cooling loads from lights and equipment less than 5 watts per square foot. System ID Lighting + Equipment Loads (W/sf) Exp 2 Single zone unitary or package systems with dehumidification that affect other systems such that air economizer would increase energy consumption. System ID Exp 3 High efficiency single zone unitary or packaged systems. Equipment cooling efficiency shall be better than the WSEC required minimum efficiency by at least 64% in Climate Zone 4C and 59% in Climate Zone 5B per Table C403.3. System ID Exp 4 Equipment that provides hydronic chilled water for chilled beams and chilled ceiling systems that is served by a water economizer system per C403.3.4 in lieu of air economizer. System ID Exp 5 Water -source heat pumps with heat recovery. Heat pump efficiency shall be 15% better than WSEC required minimum efficiency. Provide at minimum 60% air economizer. Energy recovery to preheat OSA shall have at least 50% effectiveness. Additional system requirements apply. System ID Exp 6 Cooling equipment serving Group R occupancies. Per unit limit is less than 20,000 Btu/h cooling capacity for equipment installed outdoors or in a mech room adjacent to the outdoors. For cooling equipment installed in other locations the unit limit is less than 54,000 Btu/h. Efficiency shall be 15% better than WSEC required minimum efficiency. System ID Equipment Location Cooling Capacity (Btu/h) Exp 7 Variable refrigerant flow (VRF) systems with energy recovery. Outdoor unit shall be a reverse -cycle heat pump with variable speed compressor(s) and condenser fan(s). Outdoor unit cooling capacity shall be not less than 65,000 Btu/h. Energy recovery to preheat outdoor air shall have at least 50% rated effectiveness. System shall be capable of providing simultaneous heating and cooling by tranferring recovered energy from zone(s) in cooling mode to other zone(s) that are in heating mode. Outdoor Unit System ID Cooling Capacity (Btu/h) Exp 8 Cooling equipment serving Controlled Plant Growth Environments. Equipment cooling efficiency shall be better than WSEC required minimum efficiency by at least 20%. Not eligible: unitary and applied heat pumps. System ID SEER, EER, & IEER Exp 9 Cooling equipment with energy recovery. Spaces served shall have year-round design cooling loads from lights and equipment greater than 5 watts per square foot. Energy recovery system shall utilize recovered energy for on-site space heating or preheating of service hot water. Provide calculations to the code official that demonstrate the amount of recovered energy used for on-site heating purposes is equivalent to the annual energy that would be saved by the cooling system with air economizer per C403.3. System ID Lighting + Equipment Loads (W/sf) 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 Economizer Exceptions, cont. MECH-ECONO 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised January 2017 Project Title: Date 6/18/2018 Economizer Exception Summary Refer to Section C403.3 for descriptions of economizer provisions and exceptions. For alterations refer to Section C503.4 and Table C503.4. ECONOMIZER EXCEPTIONS - NEW CONSTRUCTION AND ADDITIONS, CONTINUED Exp 10 Cooling equipment for dedicated server, electronic equipment or telecom switch rooms. Per building limit for this exception is 240,000 Btu/h cooling capacity or 10% of required building air economizer capacity, whichever is greater. Part load control required over 85,000 Btu/h. Additional requirements apply. Option a - Cooling equipment efficiency shall be 15% better than the WSEC required minimum efficiency.. Option b - Waterside economizer required. Cooling equipment efficiency shall be 5% better than the WSEC required minimum efficiency. Option c - Waterside economizer required. All cooling equipment is subject to ASHARE Standard 127. System ID Compliance Option Cooling Capacity (Btu/h) Total Claimed Exempt Capacity: Total building air economizer capacity (if claimed > 240 kBtu/h): Alternate Exp 10 Capacity Limit: ECONOMIZER EXCEPTIONS - MECHANICAL SYSTEM ALTERATIONS OR REPLACEMENT C503.4 Pre -approved design alternative to full compliance with air economizer Exp 1 requirement. An altemative for mechanical system alterations where existing building constraints make full compliance with air economizer requirement impractical. Provide calculations to the code official that demonstrate the proposed altemate design strategy provides similar energy savings to the annual energy that would be saved by the cooling system with air economizer per C403.3. System ID Alt. Strategy ECONOMIZER EXCEPTIONS - SIMPLE SYSTEMS C503.4 Qualifying small equipment. Per unit limit less than 33,000 Btu/h. Per Exp 2 building limit for this exception is 72,000 Btu/h cooling capacity or 5% of required building air economizer capacity, whichever is greater. Cooling equipment efficiency shall be 15% better than WSEC required minimum efficiency. Not eligible: non -unitary equipment, unitary equipment installed outdoors or in mech room adjacent to outdoors, equipment installed during new construction, shell -and -core construction, or initial tenant improvement. System ID Cooling Capacity (Btu/h) Total Claimed Exempt Capacity: Total building air economizer capacity (if claimed > 72,000 Btu/h): Alternate C503.4 Exp 2 Capacity Limit: C503.4 Equipment that provides hydronic chilled water for chilled water terminal Exp 3 units. Equipment part Toad cooling efficiency (IPLV) shall be better than WSEC required minimum efficiency by at least 25%. Per building limit for this exception is 480,000 Btu/h cooling capacity or 20% of required building air economizer capacity, whichever is greater. Chilled water terminal units serving Group R occupancies are not included in the building capacity total. System ID Cooling Capacity (Btu/h) Total Claimed Exempt Capacity: Total building air economizer capac ty (if claimed > 480,000 Btu/h): Alternate C503.4 Exp 3 Capacity Limit: Table Compliance Options for alteration or replacement of existing C503.4 mechanical cooling equipment per Table C503.4. Refer to table and all applicable table footnotes for full requirements. Applies to the following retrofit conditions: Option a - Any new or replacement equipment Option b - Replacement equipment of same type with same or smaller cooling output capacity. Option c - Replacement equipment of same type with large cooling output capacity. Option d - New equipment added to existing system or replacement equipment that is different than existing being replaced. System ID Equipment Type Compliance Path 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 Mechanical Fan System Power Allowance MECH-FANSYS-SUM 2015 Washington State Energy Code Compliance Forms for Commercial Buildings incl Project Title: Gateway North Bldg. 2 - RPI Date 6/18/2018 For Building Dept. Use HVAC Air Distribution System Schedule List all HVAC systems that have the capability to provide heating and/or cooling to the spaces they serve. System or Primary Supply Fan ID Speed Control (Note 1) Description (Note 2) System Total Nameplate HP (Note 3) Fan Power Calculation Required (Note 4) RTU 13 CV 48LCE007A1A6 RTU 16 CV 48KCDA06A2A6 RTU 22 CV 48KCEA04AA2A6 Note 1 - Constant Volume (CV), Variable Air Volume (VAV), or Hospital/Lab CV system that qualifies for VAV budget per C403.2.11.1 Exception Single zone VAV systems shall comply as CV. Note 2 - Describe system type and list all fans (or groups of fans) associated with the delivery and removal of conditioned air by the system. all supply, return/relief, exhaust and exhaust hoods (>1 hp), make-up air, dedicated outside air (DOAS), booster fans, and series terminals. VAV parallel fan -powered terminals and economizer relief fans do not need to be included if the fans do not operate at conditions. Note 3 - Enter the total nameplate hp of all fans associated with the delivery and removal of conditioned air by the system. Note 4 - This form automatically identifies whether a MECH-FANSYS form is required to demonstrate compliance with the fan power allowance or this information is not required because the system has a combined total nameplate motor hp that is 5 hp or less (No) 1. Include fan powered peak (Yes), MECH-FANSYS Forms A MECH-FANSYS form shall be provided for each system with total nameplate hp greater than 5 hp. Select (Adrf Fan System Form) to generate an additional form. Added forms can be deleted with button in cell E32 of the added form. 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 Mechanical Fan System Power Allowance MECH-FANSYS 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised January 2017 Project Title: Gateway North Bldg. 2 - RPI Date 6/18/2018 A separate MECH-FANSYS form must be completed for every HVAC system that exceeds the 5 hp threshold. For Building Dept. Use Fan System ID System Supply Fan Y pp Y Speed Control Constant Volume (CV), Variable Air Volume (VAV), or Hospital/Lab CV system that qualifies for VAV budget per C403.2.11.1, Exception 1 Compliance Option Compliance is based upon either the fan motor nameplate horse power (Option 1), the fan brake horsepower (Option 2), or C403.7 high efficieny VAV fan brake horsepower (10% less than Option 2). The bhp calculation provides adjustments for special equipment per Table C403.2.11.1(2). Fan System Supply Y pp y CFM Total - In Fan Equipment Schedule below, provide maximum design supply airflow rate (CFM) of all supply fans serving the conditioned space in Fan Equipment Schedule below. Fan System CFM Total is the supply airflow of the central air handler at peak design conditions. Additional volumetric air flow provided at zone fan terminals, booster fans, or through induction is not included in the supply CFM total. However, the fan power of this equipment is included in the HP and BHP calculations. Fan System Supply CFM Total is automatically calculated by the form. Fan Equipment Schedule Fan ID and Location Fan Type Quantity of Fan Type Total CFM (Note 1) Total Nameplate HP (Note 2) Total BHP (Note 3) Note 1 - Total CFM is the maximum CFM of the listed fan(s) when operating at peak design operating conditions. Note 2 - Total namplate hp of the listed fan(s). Note 3 - Total brake horsepower (bhp) of the listed fan(s) at peak design operating conditions. Not required if Nameplate HP compliance option chosen. Compliance Message: Total Proposed: Total Allowance: _._ Brake Horsepower Allowance Adjustments Device Type Description and Location CFM thorough this device (CFMD) Assigned Pressure Drop, PD in w.c. (Note 6) Calculated Pressure Drop, PD in w.c. (Note 7) Adjustment, A in bhp (Note 8) Note 4 - Bhp allowance for energy recovery devices and run around coil loops includes both air Total Adjustment (bhp): cfrnmmc cn HI. nrun is fhn cum of fhn cnnn6. MA ,,nrl nvhm„cf ('CAA :f 1...4.11 .,.. fl,...,,.,1, • the device. Note 5 - Energy recovery effectiveness is defined as change in the enthalpy of the outdoor air supply divided by the enthaply difference between the outdoor air and return air at design conditions. Note 6 - Assigned pressure drop (PD) adjustment per Table C403.2.11.1(2). Note 7 - Pressure drop (PD) adjustment shall be calculated per the applicable method defined in Table C403.2.11.1(2) based on specific system conditions. Note 8 - A = PD * CFMD/4131 where A is the allowed system brake horse power adjustment, PD is pressure drop allowance, and CFMD is the cfm through the device. 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 General Instructions: A. Include all fans directly associated with the delivery and removal of conditioned air to the zones served by the system. Enter CFM and brake horsepower (bhp) of each fan at peak design conditions and the nameplate horsepower (hp). Include supply, return and relief fans, exhaust and exhaust hood fans (>1 hp), booster fans and fans included as part of make-up air units, dedicated outside air systems (DOAS), energy recovery ventilators (ERV), and series fan -powered terminal equipment. B. VA V parallel fan -powered terminals and economizer relief fans do not need to be included if the fans do not operate at peak conditions. C. Fans not directly associated with the delivery and removal of conditioned air, such as condenser fans, do not need to be included in the fan power total. D. Fan power calculations are not required for non -central air HVAC systems such as 4 -pipe fan coils and variable refrigerant flow (VRF) systems unless individual fan systems are greater than 5hp. E. In the Brake Horsepower Allowance Adjustments table, if a Device Type is selected that has an Assigned Pressure Drop, this value will autofill into the Assigned Pressure Drop cell and the Calculated Pressure Drop cell will be write -protected. If the Device Type requires a Calculated Pressure Drop, then enter this value into the Calculated Pressure Drop cell and the Assigned Pressure Drop cell with be write protected. F. Refer to FAQ section of MECH-FANSYS-DOC for additional instructions. Nur U4- UI3 Protect-Untltled4 Prepared By: Untitiedl -r 05/21/2018 12:59PM Untitled 1 Tag Cover Sheet Unit Report Certified Drawing Performance Report Unit Feature Sheet Spec Sheet REVIEWED FOR CODE COMPLIANCE APPROVED JUL 0 3 2018 City of Tukwila BUILDING DIVISION MI 0080 LE DECEIVED COTY OF TUKWBLA JUN 092018 PEEWIT CENTER Packaged Rooftop Builder 1.49h Page 2 of 11 Project-Untitled4 Prepared BY Unit Report For tJntitied1 05/21/2018 12:59PM Unit Parameters Unit Model' 48LCE007A1A6-0NOCO Unit Size. 07 (6 Tons) Volts -Phase -Hertz..... 460-3-60 Heating Type. . Gas Duct Cfg: Vertical Supply / Vertical Return Medium Gas Heat Three stage cooling capacity control with TXV Unit Configuration Standard Static Belt Drive with VFD Controller AVCu - Al/Cu Electro Mechanical Controls Ultra LOW LEAK Temperature EconoMl$er with barometric relief Non -Fused Disconnect Standard Packaging Warranty Infonnatlon 1 -Year parts 5 -Year compressor parts 10 -Year heat exchanger - Aluminized Dlmenslons (ft. In.) & Weight (Ib.) Unit Length; 7' 4.125" Unit Width' 4' 11.5" Unit Height' 3' 6.5" — Total Operating Weight 1136 Ib "" weights and Dimensions are epprmdmete. weight does not Include unit packaging. Appro imate Chlordane are provided pdmady for shipping purposes. For exact dimensions end weights, referto appropriate product. data catalog. No optional warrantles were selected. NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity 48LCE007A1A6-0N000 Rooftop Unit 1 Base Unit Non -Fused Disconnect URra Low Leak Temp Econo X with baro relief, W7220 control. Meets Calf. Title 24 FDD & Leak Rates Packaged Rooftop Builder 1.49h Page 30111 Project-Urftltled4 Prepared BY 05121/2018 12:89PM t irrl 1 r1•ji,1IURi111•}•Ir14, 1 pa (1111111r Hail/ 1. NO, 1'.111411 111 ,t4 nil 1,4111 alt Nat ITOcc-4114 11001 t)1`` I1 CIru PI )4a ---""Mfas 11110112 0014 BACA 141 Peckeged Rooftop Builder 1.481, If no 11111 1 4-1/9 1111S01tn ry�r CNN 1 110.11E1 M0. 1111441 M-111 I1}tl r T— 11.1 101 1}MI Nit;' 4-1114 4..11111 CONY cr1OY SIZE ,/r 1111 IIA 1410 ma II11 11.1 Ilr :HI IIA N10 1•11.1 moor 1/r c111 IIA MK IQtr Put 1tr 01) 114 IIB• cam 91144 4.1 Ior-ll r1 anomie 111E1 ,Ir -Id r1 In 4Cf101 1 (111 /1A KW NMI 1110-./ IAu-TNF-TASE CARAT YIELD IIST t, ■ mr illr,M ® 1((111.11' O_�'a�L#illi. 1 lirr 144. 1 Ell11M1 3}P1r ©1 111114.1: I IV• 14171M111'1411 . 1111 �I E}.11 4-5/111011 op ti 11101 T TRU-'Nr-MASE CYAA1 IFI00) 1 nip mongol11. 1...11 7 AU01 ELM MP �1�rrr1�'.w14. '}413 LI *MO M Jr •41 IMW f. _. ...4111111944. .. R1.M 101 =EP Mitt (11rW. 14C114— Ir111tn 11KArltl 4 114 a M 111 111111 1111.11&&141 I�t 00 1.1 tea» 7/11/14 5/8/13 In Nrtl RAINT (SEC 07 SINGLE ZDNE ELECTRICAL COOLING MIT/' OAS NEAT }UI 4.14 11411 1214 1f11 r4l�(ilit � ln 48LC500311 7 Page 4 of 11 Project:—Untltled4 Prepared By 05/21/2019 12:59PM ..n I�sii` i�{t ale .t rrr Padceged p der 1.49h w. L iM iw�a1l y ‘09.. •�11 Lw. w nt 117 t i nulhaltrteltl.l1Nuliqu ®<MNISLCMI 7U t01 01(1 IT% f0`f i"Mal[' I.f1`t111r. CORNER • rRONT oar t61 T/11/15 48LO 07 SiNGEE ZONE E.ECTRICAI COOLING WM G/S HEAT CORNER R CORNER 48LC500391 Page 54:411 Prefect-Untltled4 Prepared By: 05121/2018 12:59PM Packaged Rooftop Balder 1.49P c Service Clearance D .00A -DY : %MSG CO.Cfr54 ...a... 4 rot am/ •..."larxwct a-ws.d:pato 1N P/ ors . 'dr✓Ariv t •r :.w tor.. 1114n Ea7 • 't: I saDvel t.s+.M1esre WS arta: • 4fenWesesfW . tel. LY,.Zee4C1.t:'ews+e'; Ili [[C�1 aur •Vereet fwt+r•q lAl Iwo. .. 49at. teasyy.. I Dei' f ! •r•t • .1t' I ee:se•afet 114r y1C1 .v.• • ' drw-rena NU. SII! re, W. •'..1' Jl, txwf C is ..}r11 ••••.v 1.-0. 140 tY•I"."a4 'C C WI. OA0,4 . See t3d.s1.e c.f., .41 1114, M7•ot, .VM.. CN•ty D :enc. al rr• Yi MID re• •':e L alarwp asptrl hr..r_ c_•b• ltrreltJwva.a 414 1:0f7 rni •LiDWIDE femurs E'9rrwla'• y.rY•e:.YICHtars I. awonr.nf' 14r p_e sn. •Sff-t teem !ear aetlrrrrll 4e'ttemdc••k 44..ray...•ta.1a1sl Toe! Z� as aww •CYti•jl:yT•: tr. l a.uAly 4r• r• Ifie KM 1)-'1t'Ya W.f •ast CAM Y'ws awMwld anarfk t _acicr4ers+bn iYM"Y e' (watw a- 4, •teem• ?Land./ smalaDst r•cfr, Dara saa•wy Page 8 of 11 Project: -Untltled4 Prepared By: 05/21/2018 12:59PM Part Number:48LCE007A1A6-0NOCO ARI EER: IEER: Base Unit Dimensions Unit Length. Unit Width: Unit Height Operating Weight 13.00 20.3 88.1 in 59.5 in 42.5 in Base Unit Weight 1032 Ib Medium Gas Heat: 15 lb Ultra LOW LEAK Temperature EconoMiSer with barometric relief- 74 Ib Non -Fused Disconnect: 15 Ib Total Operating Weight: 1136 Ib Unit Unit Voltage -Phase -Hertz: 460-3-60 Air DischargeVertical Fan Drive Type.. Belt Actual Airflow:. 2400 CFM Site Altitude- 0 ft Cooling Performance Condenser Entering Air DB: 95.0 F Evaporator Entering Air DB: 80.0 F Evaporator Entering Air WB:. 67.0 F Entering Air Enthalpy- 31.44 BTU/lb Evaporator Leaving Air Da. 57.6 F Evaporator Leaving Air WB: 57.3 F Evaporator Leaving Air Enthalpy ..... . 24.59 BTU/lb Gross Cooling Capacity" 74.01 MBH Gross Sensible Capacity. 57.94 MBH Compressor Power Input' 4.48 kW Coil Bypass Factor: 0.053 Heating Performance Heating Airflow- 2400 CFM Entering Air Temp' 70.0 F Leaving Air Temp: 109.7 F Gas Heating input Capacfty 90.0 / 125.0 MBH Gas Heating Output Capacity' 73.0 / 103.0 MBH Temperature Rise: 39.7 F Thermal Efficiency (%) ......... 82.0 Supply Fan External Static Pressure: 0.50 in wg Options / Accessories Static Pressure Economizer: .. _ .... _ .. 0.09 in wg Total Application Static (ESP + Unit Opts/Acc 0.59 In wg Fan RPM 659 Fan Power 0.79 BHP NOTE. The Selected Indoor Fan Motor requires a Field -Supplied Drive (RPM Range: 421 - 631). Electrical Data Voltage Range- 414 - 506 Compressor #1 RLA- 5.1 Compressor #1 LRA• 2Z Compressor #2 RLA: 6 Packaged Rooftop Builder 1.4,9h Page 7 of 11 Compressor #2 LRA: _ 44 Indoor Fan Motor Type:-- - ... .. STD Indoor Fan Motor FLA: 2.9 Combustion Fan Motor FLA (ea). 0.25 20 Power Supply MOCP (Fuse or HACK):.. 25 Disconnect Size FLA:. Discornect Size LRA...._ Electrical Convenience Outlet: Outdoor Fan [Qty / FLA (ea)]:..... Power Supply MCA: Control Panel SCCR: SkA RMS at Rated Symmetrical Voltage Acoustics Sound Power Levels, db re 10E-12 Watts 63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz A -Weighted Advanced Acoustics Discharge Inlet Outdoor 96.2 93.7 88.6 88.6 82.4 85.0 72.3 66.5 81.6 65.5 62.4 79.5 60.6 59.8 77.4 59.1 54.5 74.1 81.1 53.1 71.0 61.3 52.7 66.3 75.6 71.2 82.0 Advanced Accoustics Parameters 1. Unit height above ground: 30.0 ft 2. Horizontal distance from unit to receiver.........._._ --50.0 ft 3. Receiver height above ground: ........ __ .............._ -----_.....5.7 ft 4. Height of obstruction 0.0 ft 5. Horizontal distance from obstruction to receiver 0.0 ft 6. Horizontal distance from unit to obstruction: 0.0 ft Detailed Acoustics Information 20 87 None 211.8 Octave Band Center Freq. Hz 63 125 250 500 1k 2k 4k 8k Overall A 88.6 85.0 81.6 79.5 77.4 74.1 71.0 66.3 91.4 Lw B 62.4 68.9 73.0 76.3 77.4 75.3 72.0 65.2 82.6 LwA C 56.2 52.6 49.2 47.1 45.0 41.7 38.8 33.9 59.0 Lp D 30.0 36.5 40.6 43.9 45.0 42.9 39.6 32.8 50.2 LpA Packaged Rooftop Budder 1.49h Page 8 of 11 Project:—Untitied4 Prepared By: 05/21/2018 12:59PM Legend A Sound Power Levels at Unit's Acoustic Center, Lw B A -Weighted Sound Power Levels at Unit's Acoustic Center, LwA C Sound Pressure Levels at Specific Distance from Unit, Lp D A -Weighted Sound Pressure Levels at Specific Distance from Unit, LpA Calculation methods used In this program are patterned after the ASHRAE Guide; other ASHRAE Publications and the AHRI Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program, It Is assumed that the user is knowledgeable In the art of system sound estimation and is aware of the tolerances involved In real world acoustical estimation. This programmakes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space, an Acoustical Engineer or a person with sound prediction exxpertise should be consulted. C 2 cn co 0 co FanCurve cc RPM 559BHM.79MaxinnunRPM=1254MaxionanBHP=2.90 Note: Plossecontactapplicationfiorselectionsoutsicietheshadedtegion. SC-SystemQ rveRP-Ra edPoint Packaged Rooftop Builder .49h Page 9 of 11 _ r203131-P- y talor�AA 7tz11'iPM - 3OD9� —.i 1 1 1 1 I L I 1 1 1 1 1 1 1 J 1 05013-P [ill 1 t 1�oe3 I Y P 1 1 ,e;� m rx 3n lc m .,,, cc RPM 559BHM.79MaxinnunRPM=1254MaxionanBHP=2.90 Note: Plossecontactapplicationfiorselectionsoutsicietheshadedtegion. SC-SystemQ rveRP-Ra edPoint Packaged Rooftop Builder .49h Page 9 of 11 Project-Untltled4 Prepared By. 05/21/2018 12;59PM • Est c WeatherExpert• PACKAGED ROOFTOP GAS HEATING/ELECTRIC COOLING UMTS S. 7-5. 5.5 .na , D 0 K 5 - 48LC 'NeaherEYDe..r -AISLC s8.C.•:s41.•s•.y^te •'q 4';! -..urger•"!:: xarj ; 1 •I! -;:•{s :r•as.• is •••••sspssa'xdrp aa:..x+:: •••• "-Et--; ^ 3CC••••-3'1"S041Y.:a-:7 A: /re •s ris-su:• w�R 14::-.i 'tee••i^^.:J1 wt• %I •Y1■L1•C.t-:y =-.• N.rr: swear -r•trc:.•• E:'7: 'ti6Os3 rea•Cs-DST • r:: -:-•V's' t•a:. zi .^.Sry•s '.•y'c t^: ..EOreca-i ► ..-:1•7••=y:•1:•: 'ti: -w••:-=5': tec7;' :sI a-{ -yea • srn•:•sa.•:-• q..? £utiriTs tf^.. 3e. Packaged Rooftop Builder 1.49h STANDARD FEATir:EStt.�'DE: • a -1 .m..41 -DA -'C 7'107•:9c:: y✓s I•: • AS. -={,c SC t c -: s-: E -e ,15a':,i/�; • 1.-•e'sa' smelts.-.Er&;e• r!'s—s-se C e a • ••741a;a ctS,;:ss•Cey L.:'•-^.4".• V►••CJ le •ls:s1 • S"Ai !7'-g/7::t...:•••^•:'!Its r».VS: 1./::7:C•cc, • Es::-.•+-e:e••s"f-:::•“4.3,13., •;s's_ 47 -l< -1-:y • S:.": 1.77s! st!::E • •7:s:•esvgs • E,: -v -et .e x'TCI:} _ +;!^al:l :f- - a:tC'ef-:t •t--fE Es -:s- `.: IC::•;:is ;- sce e•:!-.Y'{7- :;er:: -yr-.ova:ete -:-a•• • I:4 ws l.]•1'Y.•tt'e- Cv'•'•-f': • ."^s::1I1.s rt S':''3 ':5", '57':, • Des; -e: • sett^s-ve .or 11:s-:r•e 1551* ••'•:" '•'oro^s : :3 Tl:r' '•a -'r .'•'s• -:ata -:.:e s_ ^ •r'tc•:e-ss•s't • 61-:4 -:IS 1i4 -^.-:i'• s I-C:'-'•'tee►:re -.•!•:' :4-• 7:f S.Pa •:.1lsts:ly ]t•sete• • Er._I.s :^sa•s:slee- •3•ae9'0e•;-u:cs..t-_E: 1^.•:D:r aa•4-CYo.'-s•u-:'7 0S4 s•: •^!i; RAY•;'.,,. • .:]: :']`..a^es -tr::c TG.S::•-:ray- • c-1C.'t•" its •Y .ei ate• -t ":11,3 s7;•• c,• es: "; • .i•: 7 it. '• ••: ;• a• Is" 1.0'sr•-: k J iTEP AWCE FEA 1 RES • •{C•1S •I -.111-:T:- s• • :v.-,Yt/Sjt:!'-: 'GT. -c3: -s •s: -'s_•zss:t••s • "-D•'•. : tetss: • 's:.- 4"••:r1 . S-ALLA-low FEATURES: • •!-ccC^'.:ar•- :d:rs • C'; e::-: yfs i -:l t:{ro a--•r:-s r r .:!^77.0.1141 •"... -; se i3:ez r-:'c+Ica • t•: t -••l•-:1"•:^ ••'c• ! :•ta-`s er••••'•' is *Cees :r•'i -e.t.at Y.'. re S.141,'4 ra:• s: i.a D+ C.::•' STANDARD .MATED PARTS *ARRANT' -rsI'a •••7 r•r-i-ge'-'5,•••e:sr•ssrer • 5•,111'011-0•es14- st► •yer;rs 2•:7s•Sr•:•--;." • Vs•y D7' c-•r:pl: 11►' -t.•2• O 'i^h'SAGCY I%C L'DE 3= 4RE ROT.IMr•ED TO' •J_.1•-: Dl.-1•$-'c.%cr:►::.^r1 •1i- Kit • .C. ,4 X^Cf^R':: T�•Jt ::3 x/:-; :;. 3-s • V:1 _s'+ _el E:1^3-'x1•r: :1•;l- f.c• :.a':1.a-• • St* -su£••e • ft: ►+7•s•p•• 1.-.11 .-.1grit!: • •7'•'-s•c r• S:.: --rte ]•/:C• --;•- I[a•73t11-t5• •_t, •:1.11 I. • D3'!-:•: 'ZT{. S.•2s•' 1st i:'+[ :!'_`•4X7:1- 1,s -or •• S•s:e-.;.:4r"i4 _2?1: ►a. cv. ':' Crit .'irSb • 5.- •is:: +r. ori S: f: r it- a.:tr••: '. a - C S ti Ce1•93.0". '.•]Tl ►-asr"S Page 10 of 11 Packaged Rooftop Builder 1.49h Page 11 of 11 5t Unit Project RPI Prepared By: 04/09/201 12:25 5t Unit Tag Cover Sheet Unit Report Certified Drawing Performance Report Unit Feature Sheet Spec Sheet Nt 6OO 8o Packaged Rooftop Builder 1.49f Page 12 of 31 04/09/2016 12:25PM rProject: RPI Prepared By: Unit Report For 5t it ' 6w.• ;all= Unit Parameters Unit Model- 48KCDA06A2A6-6U0A0 Unit Size- 06 (5 Tons) Volts -Phase -Hertz: 4604.60 Heating Type- Gas Duct Cfg: Vertical Supply / Vertical Return Low Heat Single Stage Compressor Models Units and Filters Retum Air Fitter Type: Throwaway Return Air Fitter Quantity- 4 Retum Air Filter Size: 16 x 16 x 2 Unlit Configuration Medium Static Option Belt Drive AI/Cu - AUCu Electromechanical Controls w/W7220 Econo Controller Temp Ultra Low Leak Economizer w/Baro Relief Standard Packaging Warranty Information 1 -Year parts(std.) 5 -Year compressor parts(std.) 10 -Year heat exchanger - Aluminized(std.) No optional warranties were selected. Dimensions (ft. In.) & Weight (Ib.) "' Unit Length' r 2.375" Unit Width. 3' 10.75" Unit Height 3' 5.375" Total Operating Weight 657 Ib "' Weights and Dimensions are approximate. Weight does not Include unit packaging. Approximate dimensions are provided primarily for shipping purposes. For exact dimensions arid weigher, refer to appropriate product data catalog. NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity 48KCDA06A2A6-6U0A0 Rooftop Untt 1 Base Unit Medium Static Option Bett Drive Ultra Low leak Temp Econo X with baro relief, W7220 contd. Meets Calf. Title 24 FDD & Leak Rates Packaged Rooftop Builder 1.49f Page 13 of 31 'ertife.. `? Project RPI Prepared By, 04/09/201E 1225PIr ars. Y Y[ '- A9°i°gl 71 ilLfffilib[IIIIYIYI 7. B (1477/ Of MAT 1. NO, 11Ktl101I of Alt nee 111.172 Rap run 1M -um 1t Miff 111 MIMI 111 mug) OW 22 6n I !1 LL1I Ga 1amralt iMIC..S1111II>aFin 11711 122 • L1 ,2I jiin 411T11)4 7714 11[ N 11 11L's 1 '17 # O R Watirif 11111 t1 IK1 11 1.E7r — ?LW •. r.1rl [1111 [22I174 11",111 1 I ® 1,101 Qt 111. P IIY]u"v1 14 1%? 1" 147„7 y�[pKyl{,f[-1 22111+ YfII■ .7114 7 — 4 nal TOP YY1 1 11} ^1m 71K1 fQrlT SWUM 224 111K Kan r[1 N7� 11 [111114 71414 011{ 11117111. Inc t *14• -Il n MIMI[ M11 7 11x.11 7n 11 Cn41 IKI[i'II" ei.. fQ Yt 4711, YlY1 7122 g1pp �1 1I J [III 0 11}1% 111`1 ta_®CtIMEN 6n I !1 LL1I Ga 1amralt iMIC..S1111II>aFin Em 1I11 • [EJNIY Illrirrirri:±"V;T 1�"1���� qZII� Ke Kl 7 [7711 ur a Vr KIF111144 NII 72271 —Az .1-7.411.— 7111 . nu I 171 1 K FRONT 4.fflflit1 22 111 11[1 n 111 11101111114 11221 1/n. ■ " RIGHT ■ An Packaged Rooftop Builder 1.49f 167[ 01-07 SINGLE ZONE ELECTRICAL COOLING 'ITN GAG NEAT 16RCD00261 Page 14 of 31 Praise: RPI Prepared By: ertified Drawing f .`sr 5t 04/09/201E 12:25PN •n R S1 . • I /MI5 1nl t 4 1 Rei I t.1. NWT tn. r. , (, M. FL r" l4/. aj{{1 1 R,Nt : u 71 m!'..mar eei'Leei I J11 11/1 U M 11t red:1 N 1!11 (�rl 4 21 (4 ((14 211(41 Y4 2c214.Q,t2 trut111p M /iga IIE (4114. CORNER A Packaged Rooftop Builder 1.49f TOP ritn.�oltr '�'�g�,ga�y�y� 11tl. . ■ Il.�l�1it�f1�' IBWI. tm. vE9r.n I CORNER 6 CORNER rRONT oar 242 11 IE 14 6000LLNG WITH GAS NEAT 164C606161 Page 15 of 31 ,rtifier Project RPI Prepared By: 04/09/201 ...--,._ ....,....,-... •-•. , '......, , -.... a . ..., s'''' Service ,........--",... • •••.. , x ...- , Clearance .."--...„,,.......(........"--, , ,•• i I • if , f - -- ,..., ,.., ........N..„, -........ -.... -...„. ... ....- --- -......., .., .... .../... ...„-- (99 LO:.0.0. Cl MI 1.1311CM CONL110/1 OWN • ltd roe*, lohl CnldM Mn pawl • no *MIMIC. mew try. awfat ca..r., • ,Ariertmor*0 sorAtateenne 1241(1173nrnj • Veln&rn OW. mcp a 4124n (10,0 mai. lttt •Iu Lc. And 1.40.0 leit.illa:0-1....ok& ineunly Ir.11 "17 ar.7 bn&s.1.. Oacatal roxnrksxlin• 0.&.wand flay am VW tt m A . 3,0 We &Jim.' OW No .. - X. gl4mm) Wit 017 In/ • Sda eandtassted won wad • Vinown esear.0011 0011213 Mit • lo Eke &Chris auweirybittlicl.reenetr =Mumble rrarrai 42.1+4111:17 rm. • luipte bet*r} serher 19 r&rded (e.&,matit,ntipoiry anli. anuthrwaS1;. I Woo ftl.erm) • ktine.bokinf .erttlr Ir i•ctr et 1104,09.11MdiM is & goal 14.rea.) lye id • Jae Mr at.remlors te bll Ite& rrW,a• aims 'of ton Di It Of hi Wrrs '41 weld *Mar* .1 ri.nil 11 Imo ownosel Mane.. f ',set Apl nitro frivorkra fro viviart• 'T. •••,, JO cat el Omni realm! etcrxner ef reloldeanrce& 1226P14 Packaged Rooftop Builder 1.49f Page 16 of 31 Performance Summary IS Protect: RPI Prepared By. 04/091200 12:25PN Part Number:48KCDA06A2A6-6U0A0 ARI SEER - 14.10 Base Unit Dimensions Unit Length. 74.4 in Unit 46.8 in Unit Height 41.4 in Operating Weight Base Unit Weight 597 Ib Medium Static Option Belt Drive: 10 Ib Temp Ultra Low Leak Economizer w/Baro Relief: 50 ib Total Operating Weight 657 Ib Unit Unit Voltage -Phase -Hertz 460-3-60Alr Discharge Vertical Fan Drive Type• Belt Actual Airflow: 2000 CFM Site Altitude: 0 ft Cooling Performance Condenser Entering Air DB: 95.0 F Evaporator Entering Air DB: 80.0 F Evaporator Entering Air WB: 67.0 F Entering Air Enthalpy: 31.44 BTUAb Evaporator Leaving Air DB• 58.6 F Evaporator Leaving Air WB: 57.3 F Evaporator Leaving Air Enthalpy 24.57 BTU/Ib Gross Cooling Capacity: 61.84 MBH Gross Sensible Capacity: 48.23 MBH Compressor Power Input: 5.19 kW Coil Bypass Factor 0.058 Heating Performance Heating Airflow: 2000 CFM Entering Air Temp: 70.0 F Leaving Air Temp• 97.3 F Gas Heating Input Capadty: 72.0 MBH Gas Heating Output Capacity: 0.0159,0 MBH Temperature Rise: 27.3 F Thermal Efficiency (%): 82.0 Supply Fan External Static Pressure' 0.50 In wg Options / Accessories Static Pressure Economizer Total Application Static (ESP + Unit Opts/Acc.)• 0.12 In wg 0.62 in wg Fan RPM: 1248 Fan Power 1.22 BHP NOTE: Selected IFM RPM Range: 1035 -1488 Electrical Data Voltage Range: 414 - 506 Compressor #1 RLA: 7 Compressor #1 LRA: 52 Outdoor Fan Motor Qty: 1 Outdoor Fan FLA (ea): 0.9 Indoor Fan Motor Type• MED Packaged Rooftop Builder 1.49f Page 17 of 31 Project RPI Prepared By: 04/09/201E 12:25PN Performance Summar indoor Fan Motor FLA: 4.2 Combustion Fan Motor FLA (ea)• 0.25 Power Supply MCA 14 Power Supply MOCP (Fuse or HACR)• 20 Disconnect Size FLA- 14 Disconnect Size LRA: 90 Electrical Convenience Outlet: None UNIT(s) INSTALLATION LOCATION Control Panel SCCR: 5kA RMS at Rated Symmetrical Voltage Acoustics Sound Power Levels, db re 10E-12 Watts 63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz Discharge Inlet Outdoor 87.5 87.2 87.5 82.7 79.5 82.5 75.5 68.6 76.1 71.2 63.9 73.6 67.8 63.2 71.3 82.1 57.3 67.1 63.9 53.2 64.1 59.5 45.7 60.0 A -Weighted 74.6 69.2 77.0 Advanced Acoustics Advanced Accoustics Parameters 1. Unit height above ground: 30.0 ft 2. Horizontal distance from unit to receiver. 50.0 ft 3. Receiver height above ground: 5.7 ft 4. Height of obstruction: 0.0 ft 5. Horizontal distance from obstruction to receiver: 0.0 ft 6. Horizontal distance from unit to obstruction: 0.0 ft Detailed Acoustics Information Octave Band Center Freq. Hz 63 125 250 500 1k 2k 4k 8k Overall A 87.5 82.5 76.1 73.8 71.3 87.1 64.1 80.0 89.2 Lw B 81.3 68.4 67.5 70.4 71.3 68.3 65.1 58.9 76.7 LwA C 55.1 50.1 43.7 41.2 38.9 34.7 31.7 27.3 50.8 Lp D 28.9 34.0 35.1 38.0 38.9 35.9 32.7 26.5 44.3 LpA Packaged Rooftop Builder 1.49f Page 18 of 31 Performance Sunlrn .ry Project RPI 04/09/2018 Prepared By 12:25PN Legend A Sound Power Levels at Unit's Acoustic Center, Lw B A -Weighted Sound Power Levels at Unit's Acoustic Center, LwA C Sound Pressure Levels et Specific Distance from Unit, Lp D A -Weighted Sound Pressure Levels at Specific Distance from Unit, LpA Calculation methods used in this program are pattemed after the ASHRAE Guide; other ASHRAE Publications and the AHRI Acoustical Standards. While a very significant effort has been made to Insure the technical accuracy of this program, It is assumed that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate an accurate sound prediction from user supplied Input data. If In doubt about the estimation of expected sound levels In a space, an Acoustical Engineer or a person with sound prediction expertise should be consulted. 2. 1.6 1. 0.4 0 0. Fan Curve - \00 � \ ri600 AAA \ 1r00 r\ RPM 900 RPM NW RPM-, L 1 „L r1100 RPM 5.00 BHP e 900 RPM ;00 RPM r - :.00 BHP 3.00 BHP r 500 RPM 0.75BHP , LOOBHP 1,50 r 0.0 0.3 0.8 0.9 12 1.8 18 2.1 24 Airflow (CFM - thousands) RPM = 1248 BHP =1.22 Maximum RPM = 2100 Maximum BHP = 2.90 Note: Please contact application engineering for selections outside the shaded region. SC - System Curve RP - Rated Point 2.7 30 33 Packaged Rooftop Builder 1.49f Page 19 of 31 Unit Feature Sheet for 5 Project: RPI Prepared By. 04/09/201E 12:25PN *SHIM • ct v, COfM T 7;a¢ Awa — 48KC PACKAGED ROOFTOP GAS HEATING/ELECTRIC COOLING UNITS - 14 SEER 3, 4.5 TONS Putn WEATHERMAKER SERIES WeatherMaker 48KC (t4 -SEER'. sarins are one-piece gas heating. electric cooling units that are pre -wired and &urged with Puton 4R•410) refngerent, They are'ectory tested .n b021 heating and cooling roc des, and rated to a ccardancew th AeR: Standards 2101240. Y1'eatherMertr units are designed 1n accordance with UL Standard 1995. and 1%sted try yya Undarvmlet's• Laboratories. Approved and certified Ay US Certified to 150 9001 STANDARD FEATURES INCLUDE: • Puan FR -410A) F''Cntnm•ran: • Maws fleeted' ASHRAE90 t energy •tfaancysaes • Sce.i oompres&ors erre rtemal.ne bR•k and rt.-wata( prute7rsr • Songs -stage aoo:rp at paertyconest • SEER'suptelt 0,EER'sdoto12-t • ACJrDr• retryerent materig system • ntirt-00-mket cCmtcIle Condensate pan et ecoerdanu wen ASe RAE Btend•rd 52, sloping deagn, side drde'mrdrer� • Ste+dami cooing ewntnn up to 115.F(/Q•Ci and dawn to 40'.' ct'C, - dawn to 25 • F (-4 • C) w h winter start** • °re-paanted artenorDerma. sod onrrlerco.ted nteror panes tested td 500 Noun sae cosy proteeton • Fu:y rwtoad const • E.xrtu* IOC soid•atats cantrdl for on-0oerd d•mnost•x wen LEO arias code de sermon burner coeds, loge and energy &oval(' /repo tan motor de lay • Lost** models riot rest Grooms Ac CLAIM), Mans gip men: • end,lct#d drs(igss nest c•mbusto*dray• • Redundant gas rakies see us tit two Itemise nosing • Leers -wry and nigh assure torten protected MAINTENANCE FEATURES: • Aeoess psn.ts wen easy gno hsndias • Innovetr..es ay atartng, nest,* screws on un• Itzfss pane* • T.ro.rpt d 144101011 I/ return er Sets and Tooi+sas t^ar access door • DreaDr*..- ECM edoormotor xmandate] wen eptto nal bait dite systema • Termst board ter nstngseeps safetycnruA tot plash noting and r•rrtrr d canto:0*ex arrangement • EneAran. IOC fold-ws odntro.fo• on -Ito tord daw464} n w- - :.EO •norcode dHgnaten, bum., odntrol loge one et tray savmc -roe r fon motor de toy. INSTALLATION FEATURES: • fin.tele-battampa..rentryuaab:.ty • Sn('J.pou'lgas and et•ctnoPenn•aonit • Fut roomette ease rviretN busty ramie(' *dean% and tor* :.11l41 • F•ai eenvertrdat f'emvrttcHld horeCnGl mellow STANEARO WARRANTY: • 10 -ye• r st: tions, y,•r-15-yes- s• Masa Idea a titer. • 9-vrs rept presto. • 1.1w•pJuly • Ms.) opt dna uDg'1t•seta •vMeSe OPTIONS INCLUDE BUT ARE NOT LIMITED TO: • Pttm•rt.mk and RTL: Open The. Pic moo DDC Codtroll • Suar.?and Return ai9mor:.Dineedre.tiyt.Parc miton • Le.r.r.d eo r+dtasarmeguf ids • D6eonneMvalets snit annvne«o. owelt opaves • Steniess Sb• heat epckanprc pion • Cornason Seedsnlm, cooing • Mon Roto motor eptens • astsaied Hu md•AtZat .,tatnve sell 1,1.4114ran,•, syston.T • go:Itiude s Motors Iter I or nice • Hrg.d amass pane's • fnteg'ted toono•, .'system. SUndaq and li: t Low Leek teem ns For •Consists I*' of alive, /AC aoctIsohee l.r•'to tea Product Oats CaUogfor VII una • eaten Packaged Rooftop Builder 1.49f Page 20 of 31 Project: RPI Prepared By: Spec Sheet for 5t Unit 04/09/201 12:25P Packaged Rooftop Builder 1.49f Page 21 of 31 3t Project RPI 04/09/2016 Prepared By 12:25PN 3t Unit Tag Cover Sheet Unit Report Certified Drawing Performance Report Unit Feature Sheet Spec Sheet M(8Oo90 Packaged Rooftop Builder 1.49f Page 22 of 31 Snit Report Project: RPI Prepared By 04/09/201E 12:25PN Unit Parameters Unit Model: 48KCEA04A2A6-6U0A0 Unit Size- 04 (3 Tons) Volts -Phase -Hertz: 480.3-00 Heating Type- Gas Duct Ctg: Vertical Supply/ Vertical Return Medium Heat Single Stage Compressor Models Lines and Filters Retum Air Fitter Type: Throwaway Return Air Filter Quantity 2 Return Air Fitter Size: 16 x 25 x 2 Unit Configuration Medium Static Option Belt Drive Al/Cu - AI/Cu Electromechanical Controls w/W7220 Econo Controller Temp Ultra Low Leak Economizer w/Baro Relief Standard Packaging Warranty Information 1 -Year parts(std.) 5 -Year compressor parts(std.) 10 -Year heat exchanger - Aluminized(std.) No optional warranties were selected. Dimensions (ft. in.) & Weight (Ib.) "' Unit Length. 6' 2.375" Unit Width. 3' 10.75". Unit Height: T 9.375" "' Total Operating Weight: 562 Ib ".•• Weights and Dimensions are approximate. Weight does not Include unit packaging. Approximate dimensions are provided prkna lly for shipping purposes. For exact dimension and weights, refer to appropriate product data catalog. NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering information Part Number Description Quantity 48KCEA04A2A6-6UOA0 Rooftop Unit 1 Base Unit Medium Static Oftion Belt Drtve Ultra Low leak Temp Econo X with baro relief, W7220 control. Meets Ceti. Title 24 FDD & Leak Rates Packaged Rooftop Builder 1.49f Page 23 of 31 Pro}ed: RPI Prepared By: Certified Drawing tor ?t i,r1,7 1225 1. 711$; !M :1 (ILII r lulu, Ifl Cort1 f wnir LEO, memo ar Ip 171 X11 w1(1l . 6ACK a ��ul R31�1 33 KIT J 3 II 0031J1 3 I) 3Y331 an 11 ) ti3 I''17T1i,, ?Al 11 17 M {)l1I ;1n1/; +11 ui IIIZ YR 11 jj� Ii1i 131773{ IllY mI OVIONA COIL rcgr .. 1111-■WhirEVERKLIgnellefilrl (13117711 f1711 343. 331/ 311 rats l(11 f(1n, CII 1. 1111 318 3(11 Wall I(1f3*31 Int 313 /IWI ACCESS II1 711. 1371 111 131173 C(1lla /1111111( 3131-11 377 1:011106313 113(1 IT -1111111 CONIICTIW 11/1 • IM7PIA 3(101VFW 3113-011 11.111.111 *3131 tar 11g 11110 IN IV 11(11, VIM • AM ■��r�R(Gaff I . Km 21111 llfF!CO RIMY/ALM WAR . + 11 a(1(177r 113,1 .1 milllt lq 1111 i 2�111YR M01010t3 7131313, 'Vara MnHenan yr131n'(1.'lw w tu(1[ 113 fir 1I 1717 LEFT Packaged Rooftop Bulkier 1.49f 1311 01-16.11 FRONT � 11117 nag. n WORM 1131 11TH ll Mli 1174 RIGHT tfi113 171617 4A36 04-06 S]NGLi ZONE ELECTRICAL COOLING NITH GAS NEAT 1616000261 Page 24of31 Project RPI Prepared By .;eertifinr Drawing for lt EM/05/201! 1225PN1 Yn 101 of MIIat RCU111I[SIN'tas VLI 11➢T N EL. CORNER A • lOP al coo e CORNER 8 CORNER C FRONT G=' : oat 08-16-14 1 48RC 01-O6 SINGLE /ONE ELECTRICAL COOLING WITH OAS NEAT Packaged Rooftop Builder 1.49f 401C000241 err Page 25of31 i1 i �u 1 1 INf 11 e.l. Iww L . ni P1. {SREf 1Sy�' lig lily f Y1[ 1f (I. i4 111 +M { #11131 41114 qF 1!1lm RR 114 111 ■ 1 {I L L. ,.: 1111 t/ 1 {�E7{ is S h Int YIS y i 1 ti 141 M 1. 77711f 11 IR 11 I la 11111 1 fl in r /111111 101 of MIIat RCU111I[SIN'tas VLI 11➢T N EL. CORNER A • lOP al coo e CORNER 8 CORNER C FRONT G=' : oat 08-16-14 1 48RC 01-O6 SINGLE /ONE ELECTRICAL COOLING WITH OAS NEAT Packaged Rooftop Builder 1.49f 401C000241 err Page 25of31 Certftd Drawl!) Project RPI Prepared Br 04/09/201t Service aearance ...- ‹.. ..----- ......- N.....„, ....- ---• N. ..-• N., ..--• . --- A -N. MCKIM*. ON!MOW . ...... :01ICTION A 4114.. (1211 nal, • im eivrn Iv. K niariod es rArvi ii :, pp ,..,4 • to ascrma..crwan Fa 0.011eglen • ,00mmendeat AN.kecatrAllt• Ski (KIS mrry • Vi•OKIII plitame .2.6 OW Awn, QM ATI •SA (4p. atom' Aforba• faced rouss•os AlselrI-JA rerr.snokurike r+o•orri., mg tOKIrr -Zia tar brume 5 a Fur I C*Crkit - -01w.a r irtsli - :Om (Moen, Illin 4117.4,4 - kb eamiansie down Mal • VSIAlmt. &wawa 1 deAt., N.! raw (Lag miry • vir IRA disehartt Kosaarrirgakil S'el3e 6 comb.01.1germi 478. iteC. inn - iivito Wild wai.vb =ftifia.g.,evelii,Inascrry .4&lother wit*, W•In 01/m4 • kfitabelpd mi. -1r eat wi.s."I•ctl•• 0 1. ..x.I. libres.1 Ipet•I u .1.....1,... l • .111.201V•0114.toill Or lAu Yin Pm! /At MAD VI 11.1.A., It. ai rrs onirs ••••Art row Am NOM*, planwli weasel olornolnor faairMel 1225PN Packaged Rooftop Builder 1.49f Page 26 of 31 Part Number:48KCEA04A2A6-6U0A0 ARI SEER: 14.00 Base Unit Dimensions Unit Length. 74.4 in Unit Width: 48.8 in Unit Height: 33.4 in Operating Weight Base Unit Weight: 490 Ib Medium Heat: 12 Ib Medium Static Option Belt Drive: 10 Ib Temp Ultra Low Leak Economizer w/Baro Relief: 50 Ib Total Operating Weight 582 Ib Unit Unit Voltage -Phase -Hertz: 460-340 Air Discharge- Vertical Fan Drive Type' Belt Actual Airflow: 1200 CFM Site Altitude* 0 ft Cooling Performance Condenser Entering Air DB- 95.0 F Evaporator Entering Air DB: 80.0 F Evaporator Entering Air WB: 57.0 F Entering Air Enthalpy: 31.44 BTU/lb Evaporator Leaving Air DB• 59.4 F Evaporator Leaving Air WB: 57.5 F Evaporator Leaving Air Enthalpy 24.70 BTU/lb Gross Cooling Capacity: 36.41 MBH Gross Sensible Capacity: 26.71 MBH Compressor Power Input: 2.95 kW Coil Bypass Factor. 0.113 Heating Performance Heating Airflow: 1200 CFM Entering Air Temp: 70.0 F Leaving Air Temp: 141.8 F Gas Heating Input Capacity: 82.01115.0 MBH Gas Heating Output Capacity: 88.0193.0 MBH Temperature Rise: 71.8 F Thermal Efficiency (%): 80.0 Supply Fan External Static Pressure' 0.50 in wg Options / Accessories Static Pressure Economizer 0.04 In wg Total Application Static (ESP + Unit Opts/Acc.)• 0.54 In wg Fan RPM: 846 Fan Power 0.44 BHP NOTE: Selected IFM RPM Range: 770 -1175 Electrical Data Voltage Range: 414 - 508 Compressor #1 RLA 5.8 Compressor 61 LRA 38 Outdoor Fan Motor Qty: 1 Outdoor Fan FLA (ea): 0.5 Packaged Rooftop Budder 1.49f Page 27 of 31 Performance Summar, .r-. Project RPI Prepared By: 04/09/2018 1225PN Indoor Fan Motor Type. MED Indoor Fan Motor FLA 2.5 Combustion Fan Motor FLA (ea)• 0.25 Power Supply MCA: 11 Power Supply MOCP (Fuse or HACR): 15 Disconnect Size FLA: 10 Disconnect Size LRA: 57 Electrical Convenience Outlet: None UNrr(s) INSTALLATION LOCATION Control Panel SCCR: 5kA RMS at Rated Symmetrical Voltage Acoustics Sound Power Levels, db re 10E-12 Watts Discharge Inlet Outdoor 63 Hz 83.6 85.5 78.2 125 Hz 76.4 73.6 78.0 250 Hz 68.0 59.2 74.2 500 Hz 82.7 58.8 73.3 1000 Hz 59.3 58.5 70.6 2000 Hz 53.8 52.5 66.0 4000 Hz 54.9 47.4 62.4 8000 Hz 49.1 39.0 56.9 A -Weighted 86.7 64.7 76.0 Advanced Acoustics Advanced Accoustics Parameters 1. Unit height above ground: 30.0 ft 2. Horizontal distance from unit to receiver. 50.0 ft 3. Receiver height above ground: 5.7 ft 4. Height of obstruction: 0.0 ft 5. Horizontal distance from obstruction to receiver. 0.0 ft 6. Horizontal distance from unit to obstruction: 0.0 ft Detailed Acoustics Information Octave Band Center Freq. Hz 63 125 250 500 1k 2k 4k 8k Overall A 78.2 78.0 74.2 73.3 70.8 68.0 82.4 56.9 82.9 Lw B 52.0 61.9 65.6 70.1 70.6 67.2 63.4 55.8 75.4 LwA c 45.8 45.6 41.8 40.9 38.2 33.6 30.0 24.5 50.5 Lp Packaged Rooftop Builder 1.49f Page 28 of 31 Performance Stimn ry ss: R lei Protect: RPI 04/09/2018 Prepared By: 12:25PN D 119.6 29.5 33.2 37.7 38.2 34.8 31.0 23.4 Legend A Sound Power Levels at Unit's Acoustic Center, Lw B A -Weighted Sound Power Levels at Units Acoustic Center, LwA C Sound Pressure Levels at Specific Distance from Unit, Lp D A -Weighted Sound Pressure Levels at Specific Distance from Unit, LpA 43.0 LpA Calculation methods used in this program are patterned after the ASHRAE Guide; other ASHRAE Publications and the AHRI Acoustical Standards. White a very significant effort has been made to Insure the technical accuracy of this program, it is assumed that the user is knowledgeable In the art of system sound estimation and Is aware of the tolerances Involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate an accurate sound prediction from user supplied input data. If In doubt about the estimation of expected sound levels in a space, an Acoustical Engineer or a person with sound prediction expertise should be consulted. B a 0 Fan Curve GV 1.8 — 100 RPM 1900 RPM N16o0 FPM 1.0 r 3.00 BMP. 1.4 — 900 RPM 1.2 1.0 0.8-- — 700 RPM 0.0 / zoo BMP+ 0.4 -ab RPM D.2— 1 1 1 0.60 r I BHP r r0.7s 01 P 1 1.60 aMP+ .1 00 e� I'I D.0 — 1 I I I I l -- nn ft ne .... - .- 21 Airflow (CFM - thousands) RPM — 846 BHP - 0.44 Maximum RPM = 2100 Maximum BHP = 2.90 Note: Please contact application engineering for selections outside the shaded region. SC - System Curve RP - Rated Point 2.4 Packaged Rooftop Builder 1.49f Page 29 of 31 04/09/2016 12:25PN f ;' '� t r '' F •a a. Project: RPI Prepared By: oaisksitin %eather•MakE r — 48KC PACKAGED ROOFTOP GIS HEATING/ELECTRIC COOLING UNITS — 14 SEER 3,4.5 TOWS 110 Puron WEATHERMAKER SERIES Weetherlist,er 48KC 14 -SEER) units are one-piece gas heteirg. electric coating tints that are pre -wired and charged with Puron iR-410) refngerent They are icfOry tested 'n bo71 nea!irg and cooling modes, Ind rated to accordancewrth AXR: Stencetds 210/240. :Seather%takr units ere designed in accordrnce with UL Sandard Mogi end listed by he Underwriters' Labcritories. Approved and certified US Certified to ISO19C01 STANDARD FEATURES INCLUDE • Pu•en(R.e10A1>lrFC refrigerant • Meets end exceeds AS F+rtAE 9O r energy ettcone, ell% • Sep♦wonlorassors web Atomst•.ne break and teemed protereer • Engle -Wigs cooling namely control • SEER' up to 14.0. EER's up to 12.0 • Awrtn)"• retllgeram metering system • Etna,* noncovosroesemeesnearwig n'st•0InnSOX Ms. eat with AS•iRAE Standee e2, stopop design. sell aresnterdriot • Stenciot oonW ; opemtian up to 115'F (46•Cj sod dawn to 40't .1'C) - down to 26• F;4'Ci-with venter start k4 • Pre-osarted extenor oe Mel o'mer-ooated emenor p entre, tested to 500 hours sin stray proration • Fury emulated caporal • Exces n IOC sate -irate control for on -bit ant dogmaswe wen LED ever cede des.gnaton bumercortr•el logo end energy to niedaar fan motor delay • Low 510x models Mel meet Gaeta mar A'w Ou*?y Ma nap e'rwm • Induced d rift gm t ictal oemb uttion design • Wdrnwt rt gat veH•t venh ua tw two stagts et h•anlg • Lee prerwn and hen pressure semen protected WUNTENANCE FEATURES: • Access panels welt •i -yang henries • lnnawtn• •asy paling, netted strews on writ access panels • Two-inch dnpOseota return ea' trots and Towel's tn.! pecan door • Dred Om• -E4tl rover motor es stench rd wtn optional tram dove systems • Tern'nat board fac'4sting simnel warty caved troubleshooting and saree'fod aontmlbox. irg.'* nt • Extrusive IOC so.14tate oontmftor o nbo eta daanas'..7.3w1f. LEO *Mr ' code dei .icn, bumsroontalloge enctridaysown •'eoer }ve motor d.Ly INSTALLATION FEATURES: • Thrttihi-b ottom cower entry caoab 'ty • Single pontg ea awl i4etretonn{irpnt • Fug panel', base 'i Walt buten raging seamen end lark aims • Ford a due Rd\ horevemoal to noneonte[aettbw STANCARD WARRANTY: • 10•yesrdestexc4anger- 16•Tes•its'floss Slee octan • 5M•roe mpresb' • Mary aptona upgrades also avraeta OPTIONS INCLUDE BUT ARE NOT LIMITED TO: • PR'M`rt* i and FM Open Muo nretoee. DOC tc'r,roIi • Sum/yard Nebmsk• 9'noce oaten, Molt stare irate re • LOnaerad oandensermteusrds • Delon neurweea end aomcmanoa owlet oowes • Stemless Steel neat exteonge-ccttan • Co•'Oseen re satan_mi ooe:pnp • deet atati0 meta• 001en11 • P sleeted Hunrd•UMZ. adept we as um4ecoten'attain The oat on nisei ndud•s M atoenester ! re ryas • FMged vote ss pante • Imag-orad eco non¢trsystern Stand•ro •nd L^ -v Low Leek ray -. I For • tone, tete tat or Oaten t Ind *COMM not rate• t0 rhe P rod ug Dots G1abg to• tory un/ Packaged Rooftop Builder 1.49f Page 30 of 31 Spec Sheet for Project: RPI Prepared By: 04/09/201E 12:25PN Packaged Rooftop Builder 1.49f Page 31 of 31 REVIEWED FOR CODE COMPLIANCE APPROVED JUL 032018 City of Tukwilk BUILDING DIVISION 041"11414 *--/fq it% C ` WAS1 ,, . Ocir 8959 tel <i cT�Ra L EAG e�4'� ° sS�4NAl. EN�� roL STRUCTURAL CALCULATIONS Gateway Corporate Center Bldg. 2 RTUs 12866 Interurban Avenue South Tukwila, Washington MAY 29, 2018 PREPARED FOR: Seattle Mechanical 899 West Main Street Auburn, Washington 98001 PREPARED BY: Moore Engineering Group 21902 96th Avenue SE Snohomish, Washington RECEBVE© CITY OF' TI UKWILA JUN 09 2010 PEFEOT CENTER bQ oore Engineering Group M18tX.8° GENERAL STRUCTURAL NOTES: 1. ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THESE NOTES AND THE INTERNATIONAL BUILDING CODE (IBC), 2015 EDITION. 2. DESIGN LOADING CRITERIA: ROOF LIVE LOAD MECHANICAL UNIT EARTHQUAKE WIND 25 PSF RTU -1 —1,380 POUNDS RTU -2 — 772 POUNDS RTU -3 — 677 POUNDS SDS = 0.946 SI1'h CLASS D to E 110 MPH, EXPOSURE B 3. STRUCTURAL CALCULATIONS AND SKETCHES SHALL BE USED IN CONJUNCTION WITH MECHANICAL DRAWINGS FOR BIDDING AND CONSTRUCTION. CONTRACTOR SHALL VERIFY DIMENSIONS AND CONDITIONS FOR COMPATIBILITY AND SHALL NOTIFY ENGINEER OF ALL DISCREPANCIES PRIOR TO CONSTRUCTION. 4. CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS, MEMBER SIZES AND CONDITIONS PRIOR TO COMMENCING ANY WORK. ALL DIMENSIONS OF EXISTING CONSTRUCTION SHOWN ARE INTENDED AS GUIDELINES ONLY AND MUST BE VERIFIED. THE EXISTING CONDITIONS SHOWN ON THE SKETCHES ARE BASED EITHER ON SITE OBSERVATION, ORIGINAL DRAWINGS OR WERE ASSUMED BASED ON EXPECTED CONDITIONS. IF THE EXISTING CONDITIONS DO NOT CLOSELY MATCH THE CONDITIONS SHOWN ON THE SKETCHES, OR IF THE EXISTING MATERIALS ARE OF QUESTIONABLE OR SUBSTANDARD QUALITY, NOTIFY THE ENGINEER PRIOR TO COMMENCING ANY WORK. 5. CONTRACTOR SHALL PROVIDE TEMPORARY BRACING FOR THE STRUCTURE AND STRUCTURAL COMPONENTS UNTIL ALL FINAL CONNECTIONS HAVE BEEN COMPLETED IN ACCORDANCE WITH THE DRAWINGS. 6. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES REQUIRED FOR THE COMPLETION OF THE WORK. 7. SHEET METAL SCREWS SHALL CONFORM TO THE AMERICAN IRON AND STEEL INSTITUTE (AISI) "SPECIFICATIONS FOR THE DESIGN OF COLD -FORMED STEEL STRUCTURAL MEMBERS". 8. METAL STRAPS FOR ANCHORAGE OF MECHANICAL UNITS SHALL CONFORM TO ASTM A446 GRADE A WITH A MINIMUM YIELD STRESS OF 33 KIPS PER SQUARE INCH. 9. CONNECT RTU -13 TO THE METAL CURB ADAPTER AND THE METAL CURB ADAPTER TO THE EXISTING METAL CURB WITH A MINIMUM OF (4) #12 SHEET METAL SCREWS ON EACH SIDE OF THE UNIT. PLACE ONE SCREW AT 6" TO 8" FROM EACH CORNER OF THE UNIT AND THE REMAINING SCREWS EQUIDISTANT BETWEEN. 10. AS AN OPTION FOR ANCHORAGE OF RTU -13, CONNECT THE NEW UNIT TO THE METAL CURB ADAPTER WITH FOUR (4)18 GAGE x 4-1/2" WIDE GALVANIZED METAL STRAPS AS SHOWN ON THE ATTACHED DETAIL WITH (4) #12 SHEET METAL SCREWS INTO BOTH THE UNIT AND CURB ADAPTER IN EACH CORNER OF THE UNIT ALONG THE LENGTH OF THE UNIT. PLACE THE STRAPS APPROXIMATELY 8" FROM THE CORNER OF THE UNIT. 11. CONNECT RTU -16 AND RTU -22 TO THE EXISTING METAL CURBS WITH A MINIMUM OF (3) #12 SHEET METAL SCREWS ON EACH SIDE OF THE UNIT. PLACE ONE SCREW AT 6" TO 8" FROM EACH CORNER OF THE UNIT AND THE THIRD SCREW AT APPROXIMATELY THE MIDDLE OF THE UNIT ON EACH SIDE. 12. AS AN OPTION FOR ANCHORAGE OF RTU -16 AND 22, CONNECT THE NEW UNITS TO THE METAL CURB ADAPTER WITH FOUR (4)18 GAGE x 3-1/2" WIDE GALVANIZED METAL STRAPS WITH (3) #12 SHEET METAL SCREWS INTO BOTH THE UNIT AND CURB ADAPTER IN EACH CORNER OF THE UNIT ALONG THE LENGTH OF THE UNIT. PLACE THE STRAPS APPROXIMATELY 8" FROM THE CORNER OF THE UNIT. UN r 5.H c-ck4_-.\/ ,- PE lt_ L-- STr�c'r>L 4 - { -' f "e'�..:%�-ice �•'. ,+.o •;.'L oore engineering ,'Jrouto PROJECT: 6L- z- -rUS ENGR: DATE: Fj�r SCALE: SHEET PROTECT DESCRIPTION: The project consists of the replacement of three existing rooftop mechanical units. LOADS: LIVE DEAD DEAD + LIVE WIND SEISMIC Roofing and re -roof 1/2" plywood sheathing 2x4 @ 24" on -center 4x14 @ 8' on -center Insulation MEP Lights & Miscellaneous Total Dead 110 mph, Exposure B Latitude Longitude Site Class SDS (C) = SDS (D) = SDS = EQUIPMENT Existing RTU -13 Unit 538 Existing Curb 115 Curb Adapter - Total 653 pounds Dimensions 4.0 1.5 0.7 1.6 1.0 2.0 2.2 13.0 25 PSF 38 PSF 47.486 -122.274 D to E WA DNR 0.996 0.896 0.946 New RTU -13 1,136 115 129 1,380 pounds 88"x60"x66" high Moore Engineering Group PROJECT: GATEWAY NORTH BLDG. 2 RTUs ENGR: KWM DATE: 5/25/ 18 SCALE: SHEET LOADS: (continued) Existing RTU -16 New RTU -16 Unit 578 657 Existing Curb 115 115 Total 693 pounds 772 pounds Dimensions 74"x47"x53" high Existing RTU -22 New RTU -22 Unit 548 562 Existing Curb 115 115 Total 663 pounds 677 pounds Dimensions 74"x47"x45" high Moore Engineering Group PROJECT: GATEWAY NORTH BLDG. 2 RTUs ENGR: KWM DATE: 5/25/ 18 SCALE: // G SHEET 5/21/2018 Design Maps Summary Report USGS Design Maps Summary Report User -Specified Input Report Title Gateway North BIdg.2 RTUs Mon May 21, 2018 23:48:00 UTC Building Code Reference Document 2012/2015 International Building Code (which utilizes USGS hazard data available in 2008) Site Coordinates Site Soil Classification Risk Category LIP NAVAL Vastiort 9uriet. 47.486°N, 122.274°W Site Class D - "Stiff Soil" I/II/III SEATTLE TACOM4 4.F Des Mores,,, USGS-Provided Output Ss = 1.494 g S1 = 0.560 g Sias = 1.494 g SM1 = 0.839 g Issaquah titL`r;, :AI 4. 4 'Renton Maple Valley Sos = 0.996 g Sc1 = 0.560 g F .N For information on how the SS and S1 values above have been calculated from probabilistic (risk -targeted) and deterministic ground motions in the direction of maximum horizontal response, please return to the application and select the "2009 NEHRP" building code reference document. MCER Response Spectntm n.]. 1141, nbl n211 1!n 1 ]1 14,1 10, 11.1' -!'l Period. T rsv► Design Response Spectrum ill/1 11,]1 1141, ,'ft' t.9, 1,'1 111 Prrtod. T ism) 11• 1141 (}il Although this information is a product of the U.S. Geological Survey, we provide no warranty, expressed or implied, as to the accuracy of the data contained therein. This tool is not a substitute for technical subject -matter knowledge. 643 httpsJ/earthquake.usgs.gov/cn2/designmeps/us/summary.php?template=minimal&latitude=47.486&longitude=122.2748,siteclass=381riskcategory=0&edition=ibc-21 5/21/2018 Design Maps Summary Report (� Design Maps Summary Report User -Specified Input Report Title Gateway North BIdg.2 RTUs Mon May 21, 2018 23:48:14 UTC Building Code Reference Document 2012/2015 International Building Code (which utilizes USGS hazard data available in 2008) Site Coordinates 47.486°N, 122.274°W Site Soil Classification Site Class E - "Soft Clay Soil" Risk Category I/II/III i" fir's `d i aS.,4R+flc Vasho , Biurien« TACOMA N71. A (P'PfYi Des Moines,, USGS-Provided Output Ss = 1.494 g S1 = 0.560 g 'J '''6 FL!:rte SMS= 1.344g SM3 = 1.343 g ' E is TO N ,y;sc2o �► enton • Issaquah Male Valley Sps = 0.896 g SD1 = 0.895 g .N( For information on how the SS and S1 values above have been calculated from probabilistic (risk -targeted) and deterministic ground motions in the direction of maximum horizontal response, please return to the application and select the "2009 NEHRP" building code reference document. NICER Response Spectrum Period. T ism) Design ResponseSpertrum 03, •.y• ..A. Izr. 1 3. I /., ! n. 21.. Period, T tsar) Although this information is a product of the U.S. Geological Survey, we provide no warranty, expressed or implied, as to the accuracy of the data contained therein. This tool is not a substitute for technical subject -matter knowledge. https://earthquake.usgs.gov/cn 1/designmaps/us/summary.php?template=minimal&latitude=47.486&longitude=122.2'74&siteciass=4&riskcategory=0&edition=ibc-21 Moore Engineering Group PROJECT: 5L.t- L703 ENGR: DATE: 9A SCALE: ?)41 SHEET Physical data BASE UNIT SOD.. NOMINAL CAPACtTY (tons) OPERATING WEIGHT (Ib) Unit With Economizer Roof Curb COMPRESSOR Manufacturer Oty...T pe 011(oz) REFRIGERANT Operating Charge (Ib -oz) CONDENSER FAN Qty...Dlameter (In.) Nominal Cfm Motor Hp ..Rpm CONDENSER COIL Rows—Fins/In. Total Face Area (sq ft) EVAPORATOR FAN Size (M.) Type Drtve Nominal Cfm Motor Hp ..1110311 435 445 465 520 453 463 483 538 115 ......115._._ __._ 115 115 Hermetic Carlyle Carlyle Copeland Carlyle 1 . J37 1. J48 1 .CRP5 1 W72 48 48 70 _ _ . 64 .... R-22 4-3 5-4 6-11 L 9-0 Prope ler Type 1 280 1..260 1 280 ' 1 260 3500 4100 4100 3800 1/2..,850 h...850 h...850 i h...850 Motor Frame Nominal Rpm High/Low Fan Rpm Range Maximum Fen Rpm Motor Pulley Pitch DiameterA/B in.) Fan Pulley Pitch Diameter (In.) Belk Type...Length (In.) Pulley Center Line Distance (In.) Speed Change per Full Turn of Movable Pulley Flange (rpm) Movable Pulley Maximum Full Turns From Closed Position Factory Setting — Full Turns Open Factory Speed Setting (rpm) Shaft Diameter at Pulley On.) Std Alt Std Alt Std Alt Std Alt Std Alt Std Alt Std Alt Std Alt Std Alt Std Aft Std Aft Std Alt Std Alt Enhanced Copper Tubes, Aluminum Lanced Fin 1 17 1..15 1 1. 17 _ -- 2..17 7.78 12.25 12.25 12.25 10 x 10 Direct Direct 1200 'h ,h 48 48 860/845 1080/970 860/845 1080/970 2100 2100 Centrifugal Type 10 x 10 10 x 10 Direct Belt 1600 ,h y, 48 58 1080/970 1080/970 1160/880 2100 2100 2 4/3 4 5.2 A 43 15 5-14 7 60 5 5 860 146 Direct Belt 2000 10 48 56 1080//040 1080/1040 1130/ 850 2100 2100 2 4/3 4 52 A...43 15 5-14.7 5e 5 5 880 1% li 10 x 10 Belt Belt 24001 15 56 56 1110/ 836 1400/1040 2100 2.4/3.4 2.8/3 8 52 5.2 A .43 15 5-14 7 15 2-14 4 55 72 5 5 5 5 835 1040 1% EVAPORATOR COIL Rows—Firm/In. Total Face Area (sq ft) HIGH-PRESSURE SWITCH (prig) Cutout Resat Enhanced Copper Tubes, Aluminum Double -Wavy Fin 2 15 2 15j 3 .15 U 4 15 4 17 5.5 5.5 5.5 428 320 LOW-PRESSURE SWITCH (psig) Cutout Reset OUTSIDE AIR INLET SCREENS* Qty...Slze (in.) 27 ± 4 RETURN AIR FILTERSt Qty...Slze (In.) 1...20x24x1 2 16x25x2 * Cleanable t Disposable ARI capacities UNIT SODJ NOMINAL TONS STANDARD CFM NET COOLING CAPACITY (Btuh) TOTAL kW — EER SEER BELS With Time Without Timer 004 3 1200 35,000 4.2 8 4 9 5 9 3 8 2 005 4 1600 48.500 5.8 8 5 9 5 9 3 8.2 006 5 2000 60,000 7 1 8 5 9 5 9.3 8 2 OOT 6 2400 71,000 8 2 8 7 — — 8 2 BELS — Sound Levels (1 BEL=10 decibels) EER — Energy Efficiency Ra lo SEER Seasonal Energy Efficiency Ratio Rated In accordance with ARI Standards 210-81, 240-89 and 270-82 Ratings are net values, reflecting the effects of circulating fan heat. Ratings are based on Cooltng_Standard: 80 F db, 87 F wb Indoor entering air temperature and 95 F db air entering outdoor unit 3 Physical data BASE UNIT 48 SERIES OJE004 DJD/DJE00S 13JO/DJE008 DJD/DJEOOT NOMINAL CAPACITY 3 4 5 6 -OPERATINGWEIGHT(lb) Unit With Economizer Roof Curb 530 548 115 540 558 115 560 578 115 615 633 115 COMPRESSOR He mettc Manufacturer Carlyle - J37 f Carlyle - J48 Copeland - CRP5 Carlyle - W72 Ouantity...Type 1 1[ 1 1 1 011(oz) 48 48 70 64 REFRIGERANT R-22 Operating Charge (ib -oz) 4-3 5-4 6-11 9-0 CONDENSER FAN Propeller Ouentity...Diameter (in.) 1.. 26 1 26 1 ..26 1.. 26 Nominal Cfm 3500 4100 4100 380D Motor Hp...Rpm 'h . 850 'h ..85D '/. 850 h 850 CONDENSER COIL Enhanced Copper Tubes, Aluminum Lanced Fin Rows...Flne/In. 1 .17 1 17 1 . 17 2 .17 Total Face Area (sq It) 7 78 12 25 12 25 12.25 EVAPORATOR FAN Cen rifugal Sire (In.) 10 x 10 10 x 10 10 x 10 10 x 10 Type Drive Std Alt Direct Direct Direct Belt Direct Belt Belt Belt Nominal Cfm 1200 1600 2000 2400 Motor Hp Std Alt 'h h '/z % 34 1 0 1 0 1 5 Motor Frame Std Alt 48 48 48 58 48 56 56 56 Nominal Rpm High/Low Std Alt 880/845 1080/970 1080/970 — 1080/1040 Fan Rpm Range Std Alt 860/845 1080/970 1080/970 1160/860 1080/1040 1130/ 850 1110/ 835 1400/1040 Maximum Fan Rpm Std AM 2100 2100 2100 2100 2100 2100 2100 2100 Motor Pulley Pitch Diameter Std — — — 2 4/3 4 MB (in.) Alt — 2 4/3 4 2 4/3 4 28/3 8 Fan Pulley Pitch Diameter (in.) Std AR — -- — 5 5 Balt — T Length (In.) Ype... -- - AS 43 A. 43 A,. 43 Pulley Center Line Diligence (In.) — 14 25 14 25 14 25 Speed Change Per Full Turn of Std — — — 55 Movable Pulley Flange (rpm) Alt — 60 58 72 Movable Pulley Maximum Full Std — — 5 Turns From Ctosed Posttton Alt — 5 5 5 Factory Setting — Full Turin Open Std Alt _ — 5 — 5 5 5 Factory Speed Setting (rpm) Std AH 860 850 833 1040 EVAPORATOR COIL Enhanced Copper Tubes, Aluminum Double Wavy Fin Rows...FIne/In. 2. 15 2 15 3 15 4.15 Total Face Aree (sq tt) 417 5 5 5.5 5 5 FURNACE SECTI&4 Burner Orifice Diameter (in. ...drill size)' Natural Gas — Std 116...32 116 32 .116 32 118 32 Liquid Propane — Alt 089..43 089 43 .089. 43 089. 43 Thermostat Hell Anticipator Setting (amps) 208/230/488 v 1 0 1 0 1 0 1 0 Ges Input 74,000 74.000/115,000 74,000/115.000 74,000/115,000 Efficiency (AGA Steady State) (%) 79 79 79 79 T.mpereture Rise Range 25-55 35-65/25-55 35-65/25-55 35-85/25-55 Manifold Pressure (In. wg) Natural Gas — Std 3.5 3 5 3 5 3 5 Liquid Propane — Alt 3.5 3 5 3 5 3 5 Maximum Static Pressure (In. wg) .75 .75 .75 75 Field Gas Connection Size (In.) .5 .5 5 .5 HIGH-PRESSURE SW(fCH (psig) Cutout 428 Reset 320 LOW-PRESSURE SWITCH (peig) Cutout 27 t 4 Reset 87 ± 7 OUTSIDE AIR INLET SCREENS Cleanable Quantity...Size (!n.) 1 20 x 24 x 1 RETURN AIR FILTERS Disposable Quantity...Size (In.) 2. 18 x 25 x 2 48DJ0005-007 and 48DJE004 (74,000 Btuh) units have 2 burners 48DJE005-007 (115,000 Btuh) units have 3 burners 3 Physical data e BASE UNIT46SERIE'8 03E004 DJD/111E005 Dio/0JE008 DJD/OJl007 NOMINAL CAPAC 3 4 5 8 OPERATING WEIGHT (lb) /MU With Economiser Roof Curb 530 548 115 540 558 115 t 5578 115 815 633 115 COMPRESSOR Manufacturer OuaMlty.»TyPe ON (oz) Carlyle - J37 1 48 Hermetic Carlyle - J48Copeland 1 48 ` - CRPS 1 70 Carlyle - W72 1 64 _ REFRIGERANT Operating Charge (lb -oz) R-22 4-3 S-4 6-11 1 9-0 C. ' J'TTJ• 1' Propeller Ouantihr Alameter (In.) Nominal Motor tor Hp...„Rpm 1.. 26 3500 'A830 1 26 ' 4100 14.850 1 1 ..26 L. 28 400 3800 54.'850 let 850 CONDENSER COIL Enhanced Copper Tubes, Aluminum Lanced Fin Rowne.Fine/In. 1 .17 1 1 17 1 . 17 2 .17 1 Total Face Area (sq ft) 7 78 1 12 25 1 12 25 12.25 EVAPORATOR FAN Centrifugal Mae (M.) 10x10 10x10 10x10 10x10 Type Drive Std Alt Direct Direct Direct Belt Direct Belt Belt Belt Nominal Ctm 1200 1600 2000 2400 Motor Hp Std Alt 'Is Y 'h * * 10 1 0 15 Motor Frame � as 448 48 8 48 56 56 Nominal Rpm High/Low Std Alt 880/845 1080/970 1080/970 1080/1040 Fen Rpm Range Std Alt 860/845 1080/970 1080/970 1160/860 1080/1040 1130/ 850 1110/ 835 1400/1040 Maximum Fan Rpm Std Alt 2100 2100 2100 2100 2100 2100 2100 2100 Motor Pulley Pitch Diameter Std — — — 24/3 4 AIR 00 Amid -- 24/34 2 4/9 4 2 8/3 838 Fen Pulley Pitch Dlemeter (in.) Alt _ Bell --Type—(In.) A 43 A. 43 A. 43 Pulley Center Line Distance (M.) — 1426 14 25 14 25 Speed Change Per Full Turn of Sid — — — 55 Movable Putiey Flange (rpm) Alt -- 60 58 725 Movable Pulley Maximise Full Std -_ --— Turns Prom Closed Position Ari — 5 5 5 AitSFactory Setting --Full Turns Open — 5 5 5 Factory SPS Setting (rpm) Alt . $80 850 1040 EVAPORATOR COIL Enhanced Copper Tubes, Aluminum Double Wavy Fin Rows...Fine/ln. 2. 15 2 15 3 15 4.15 'Total Face Area (sq tt) 417 5 6 5.5 5 5 FURfaCE SECl1l h Bunter OrlfIce Diameter (in. —drill site)' Natural Gas _ Std 118..22 118 32 .116 32 116 32 Liquid Propane — Alt 089. .43 089 43 .089. 43 089.43 Thermostat Heal Anticipator Setting (amps) 2061230/480 v 1 0 1 0 1 0 1 0 Gee Input 74,000 74,000/115.000 74,000/115,000 74,000/115,000 (AGA)( Steady States) fold Preteens tin. tug) 25-55 35-85/25-55 79 35-86/25.55 35-6578 /25-55 Natural Gas— Sid 3.5 3 5 3 5 3 5 ��W Propane— AR Maxfntatm Sodic Pressure (In. tug) 3.5 .75 75 75 Field Gee Connection Sboe (In.) .5 .5 5 .5 HIGH-PKINSURE INTIICH (Ping) 428 Rutout esit 320 I5 ,-PRESSURE SWITCH (psig)Cutout 27 t a Reale 67 t 7 OUTSIDE AIR INLET SCREENS Cleanable Quantity—Styr (pr.) 1 20 x 24 x 1 RETURN Alt FILTERS Disposable Quantity...Sias0n.) 2. 16 x 25 x 2 •48DJD005-007 and 48DJE004 (74,000 Btuh) units have 2 burners 48DJE005.007 (118,000 Btuh) units have 3 burners 3 7Zrc1-13 Unit Parameters Unit Model:.......... __ 48LCE007A1A6-0NOCO Unit Size: 07 (6 Tons) Volts -Phase -Hertz: .460-3-60 Heating Type:. _ ..__ .... Gas Duct Cfg:.... __._ _ _ Vertical Supply / Vertical Return Medium Gas Heat Three stage cooling capacity control with TXV Unit Configuration Standard Static Belt Drive with VFD Controller Ai/Cu - Al/Cu Electro Mechanical Controls Ultra LOW LEAK Temperature EconoMi$er with barometric relief Non -Fused Disconnect Standard Packaging Warranty Information 1 -Year parts 5 -Year compressor parts 10 -Year heat exchanger - Aluminized Dimensions (ft. in.) & Weight (Ib.) "* Unit Length: Unit Width:.........__.. Unit Height:.. Total Operating Weight - 7' 4.125" 4' 11.5" 3' 6.5" 1136 Ib "• Weights and Dimensions are approximate. Weight does not include unit packaging. Approximate dimensions are provided primarily for shipping purposes. For exact dimensions end weights, refer to appropriate product data catalog. No optional warranties were selected. NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity 48LCE007A1A6-0NOCO Rooftop Unit Base Unit 1 Non -Fused Disconnect Ultra Low Leak Temp Econo X with baro relief, W7220 control. Meets Calf. Title 24 FDD & Leak Rates Packaged Rooftop Builder 1.49h Page 3of11, lexc) - 1 011111!tt lr alit 1111(0( •41EIT1 1 1111111(1 01 111 :101 111 Mt 11 C1110'1 rl 101: 1101 1 W 1;1 list 11_$11,1A t It .3 . ,1 rirrorri n { n4: o.'A. x4.1!1 —1411 vz< 11.01 TOP o 01101) CONA'ECIlOA SIZES 0,e• 4111 1:0 11011 ,0101 111,41 0011. 1 1 112• '141 100 10411 310911 11001011 ' C I .• Oil 111 4110( 0K(13 1100 110 1401 011 11111 044040. 11014 .7 11• -II 111 (411101,1,1 010:4 14 111 041 (0030(111(4 • (111 111 r01,11, ATa1 WWI -01.. fiR.-1of•eASE CHART I�IFEB 1117 11(1 11111 110111{0 f0 011111 1010 a1•8110/N,1: 544 '110 (111 (114g1Xu11: Mt •110 Marts m:eawi p o nt 1 114. '012,44.1 1 001E1 1114 1(0 1 10V qt 1ia3 4141. I101•2, Pdl011 111• ttl ♦tip 0011 Rl44I 1 2111115. 1041 (122: 1. 2X.0 THRLI--HE-RASE CHAR! 11011(wM1r04 0111 1. 1, 21 1 0(1 fl(llW0. • • M1a 160.11111 1[0(11. .11414 e ,04:00 113. 10440({ II aWIlIO •• ((4([11 41!1 111 01(':44 114 411 v41a 11171 0•11 1101,10.,1 7111/11 ! 5/8/13 181C :1 S:Hb-L IOW ELECTRICAL COOLING M?'= GAS HEAT 48LCS0t391 Packaged Rooftop Builder 1.49h Page 4 of 11 -t5 Part Part Number:48LCE007A1A6-ONOCO ARI EER:.... IEER: Base Unit Dimensions Unit Length: Unit Width: Unit Height: Operating Weight Base Unit Weight: Medium Gas Heat: Ultra LOW LEAK Temperature EconoMi$er with barometric relief* Non -Fused Disconnect: Total Operating Weight: 13.00 20.3 88.1 in 59.5 in 42.5 in 1032 Ib 15 Ib 74 Ib 15 ib 1136 Ib Unit Unit Voltage -Phase -Hertz: _ _ .. 480-3.60 Air Discharge:. ... . Vertical Fan Drive Type: .. Belt Actual Airflow:. .__ _ ... _ 2400 CFM 0 ft Site Altitude: Cooling Performance Condenser Entering Air DB:. 95.0 F Evaporator Entering Air DB: 80.0 F Evaporator Entering Air WB:.. .67.0 F Entering Air Enthalpy: 31.44 BTU/lb Evaporator Leaving Air DB: 57.6 F Evaporator Leaving Air WB: .57.3 F Evaporator Leaving Air Enthalpy 24.59 BTU/ib Gross Cooling Capacity:..._. 74.01 MBH Gross Sensible Capacity: 57.94 MBH Compressor Power Input:.. . 4.48 kW Coil Bypass Factor: 0.053 Heating Performance Heating Airflow: _ 2400 CFM Entering Air Temp ....70.0 F Leaving Air Temp: . 109.7 F Gas Heating Input Capacity: 90.0 / 125.0 MBH Gas Heating Output Capacity: 73.01103.0 MBH Temperature Rise. 39.7 F Thermal Efficiency (%):.. 82.0 Supply Fan Extemal Static Pressure:_. .... 0.50 in wg Options / Accessories Static Pressure Economizer: 0.09 in wg Total Application Static (ESP + Unit OptslAcc.) 0.59 in wg Fan RPM:.._ ... 659 Fan Power: . 0.79 B -IP NOTE:. The Selected Indoor Fan Motor requires a Field -Supplied Drive (RPM Range: 421 - 631). Electrical Data Voltage Range:. 414 - 506 Compressor #1 RLA: 5.1 Compressor #1 LRA.:. _ no Compressor #2 RLA: 6 Packaged Rooftop Builder 1.49h Page 7 of 11 S 3 w 0 o, 0 e z r 28 i¢,L' ww n IP -J N W wee au N C Otag ! o@o , g111* In gmM 11. eQ90 (6] o a Q QF�_p, V N ~ W 022 M 4 mai 1 M. z mgi if ?AT, om Cif--)5Y-1(D e-1278"42 ..--- P . r re 31,J(ctrw. 3,gi(155.) = 135�1�,c.l�r Fed --:;(64).Y,°"71.)/ r: = i� 7q /r - Cbrt)ed'tli !'e - r411 - 11 (q`-( - Z 3101.; 4- qrl sL CAP= 3 a( 1( 1-110(rJ4 << Iho(s... o� der - v►.o -7u,)-` t1ati o., to e crh'v (5*- (or: oitt +0 41447 1 Z'� 3 72 — =23401 ` - 3 i � Ac- V/. :91? -0,-1 Moore Engineering Group PROJECT: ENGR: 14)73K DATE: C(Zq'112,, SCALE: (% SHEET' p A 6,1 h� (net 4, 07E- 0) 4a2 5 k -S D�� T tor i4,(ti 5 ctry ,l,71_, tck)4lz t.;4Q tjt�f w -curia" -e ` " Moore Engineering Group PROJECT: ENGR: /(0-1r)'l( DATE: P)/ SCALE: )670 SHEET 04/09/2016 1225PM Project: RPI Prepared By: Unit Report For 5t Unit Unit Parameters Unit Model: 48KCDA06A2A6-6U0A0 Unit Size- 08 (5 Tons) Volts -Phase -Hertz: 4603.60 Heating Type* Gas Duct Cfg: Vertical Supply / Vertical Return Low Heat Single Stage Compressor Models Lines and Filters Retum Air Filter Type: Throwaway Retum Air Filter Quantity 4 Return Air Filter Size: 16 x 18 x 2 Unit Configuration Medium Static Option Belt Drive Al/Cu - AI/Cu Electromechanical Controls w/W7220 Econo Controller Temp Uftra Low Leak Economizer w/Baro Relief Standard Packaging Warranty Information 1 -Year parts(std.) 5 -Year compressor parts(std.) 10 -Year heat exchanger - Aluminized(std.) Dimensions (ft. In.) & Weight (Ib.) Unit Length* 6' 2.375" Unit Width- 3' 10.75" Unit Height: 3' 5.375" •N Total Operating Weight:. 657 Ib ••' Weights and Dimensions are approximate. Weight does not include unit packaging. Approximate dimensions are provided primarily for shipping purposes. For exact dimensions and weighs, refer to appropriate product data catalog. No optional warranties were selected. NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information Part Plumber Description Quantity 48KCDA06A2A6.6U0A0 Rooftop Unit 1 Base Unit Medium Static Option Belt Drive Ultra Low leak Temp Econo X with baro relief, W7220 control. Meets Calf. Title 24 FDD & Leak Rates Packaged Rooftop Builder 1.49f Page 13 of 31 itC6"(6° • Project: RPI Prepared Bv: 04/09/201E 12:25PM 10,1.5: mI 15*ic itr$ dlu:K 11(l [61J lI 2. '3 (41411 Jr WW1. f. y 11*[(•101 or 511 rite 011r oft 1 I!e( e5 rout 00 101 [ 1M1(1110* SIRS rl• 151l 041 5111.0 00101 111111 11 0:0 10011 Wry o0[LL1 — I: 1511 01.0 0*1*1 40(51 KW 0 1 • (211 011710(01011104 110114 5*14 r 415-•17 Irl W0e10111 *0011 0';14 541 GS [01\I07i00 'rf ' IIII 110 IG*I r0M[1110[r.(al v*91r;xll( 1501 11410 x0(00 10011500 10t 110 1. c1111MM11001. 001001 IICOD(0 [*00011 5414 lees Irr Fr 511 •IILLd11.6[(M.• ,111111 nr(011 f (mugs FOR tear 1.0, 510 M*l00 0E(Eer (04101 010. 00 110' rte 001(1, 0[1(454* 01 7100 riff I1o1: t5 01040 SII' r Ill 5400 ❑r*(1 r:711104 OSP 07 7 fRO.IT 09 19-11 I I&KC 04.01 0;NGIE ZONE EL*CIRICAL GgKC Y, 0781 COOLING 91-11 (0.5 NEAT 1 Packaged Rooftop Builder 1.49f Page 14 of 31 4-c0 - ((p Part Number:48KCDA06A2A6-6U0A0 ARI SEER• 14.10 Base Unit Dimensions Unit Length. 74.4 in Unit Width: 46.8 in Unit Height: 41.4 in Operating Weight Base Unit Weight: 597 lb Medium Static Option Belt Drive: 10 ib Temp Ultra Low Leak Economizer w/Baro Relief: 50 Ib Total Operating Weight: 657 tb Unit Unit Voltage -Phase -Hertz: 460-340 Air Discharge. Vertical Fan Drive Type- Belt Actual Airflow: 2000 CFM Site Altitude: 0 ft Cooling Performance Condenser Entering Air DB: 95.0 F Evaporator Entering Air DB: 80.0 F Evaporator Entering Air WB: 67.0 F Entering Air Enthalpy: 31.44 BTU/lb Evaporator Leaving Air DB• 58.6 F Evaporator Leaving Air WB: 57.3 F Evaporator Leaving Air Enthalpy 24.57 BTU/lb Gross Cooling Capacity: 61.84 MBH Gross Sensible Capacity: 46.23 MBH Compressor Power Input: 5.19 kW Coil Bypass Factor: 0.058 Heating Performance Heating Airflow: 2000 CFM Entering Air Temp: 70.0 F Leaving Air Temp* 97.3 F Gas Heating Input Capacity: 72.0 MBH Gas Heating Output Capacity: 0.0 / 59.0 MBH Temperature Rise: 27.3 F Thermal Efficiency (%)• 82.0 Supply Fan External Static Pressure* 0.50 in wg Options / Accessories Static Pressure Economizer 0.12 in wg Total Application Static (ESP + Unit Opts/Acc.)• 0.62 in wg Fan RPM. 1248 Fan Power 1.22 BHP NOTE: Selected IFM RPM Range: 1035 -1466 Electrical Data Voltage Range: 414 - 506 Compressor #1 RIA• 7 Compressor#1 LRA• 52 Outdoor Fan Motor Qty: 1 Outdoor Fan FLA (ea): 0.9 Indoor Fan Motor Type• MED Packaged Rooftop Builder 1.49f Page 17 of 31 Unit Parameters Unit Model: 418KCEA04A2A6-6U0A0 Unit Size 04 (3 Tons) Volts -Phase -Hertz' 460-3-60 Heating Type• Gas Duct Cfg: Vertical Supply / Vertical Return Medium Heat Single Stage Compressor Models Lines and Filters Retum Air Filter Type: Throwaway Retum Air Filter Quantity 2 Return Air Filter Size: 16 x 25 x 2 Unit Configuration Medium Static Option Belt Drive AI/Cu - AI/Cu Electromechanical Controls wIW7220 Econo Controller Temp Ultra Low Leak Economizer w/Baro Relief Standard Packaging Warranty Information 1 -Year parts(std.) 5 -Year compressor parts(std.) 10 -Year heat exchanger - Aluminized(std.) No optional warranties were selected. Dimensions (ft. In.) & Weight (ib.)'*` Unit Length. 6' 2.375" Unit Width' 3' 10.75" Unit Height: 2' 9.375" �• Total Operating Weight: 562 Ib "• weights and Dimensions are approximate. weight does not Include untt packaging. Approximate dimensions are provided primarily for shipping purposes. For exact dimensions and weights, refer to appropriate product data catalog. NOTE; Please see Warranty Catalog 500.089 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity 48KCEA04A2A6-6U0A0 Rooftop Unit 1 Base Unit Medium Static Option Belt Drive Ultra Low leak Temp Econo X with baro relief, W7220 control. Meets Calf. Title 24 FDD & Leak Rates Packaged Rooftop Builder 1.49f Page 23 of 31 Project: RPI Prepared By: o4,os,2o11 12:25PAM im13 M<�I I. lI Ilenei 3)l ur(h l(M61tl{S 1. 19 1333 Of 1113111 1. y 111<'Id 01 111 0101 421 e/ oar s$ ext !1 1 1 11 *1411 Il/Ll 111111 33 ) 10)1' 11l1;1 1.417711 I fFT 111i 11-1/1 111314 151114 1•: { 1 E y� t•t a {V4 ^;`�il 1� UMf - -- n-111 --�1 ` IW�M9111 NAl l 111 x341 nwlr Ila: 4 rte; 25-slt It-ir1 xiiei'm i qm erm2 191 O rl i nu PrI 111)1 1ft 1I 1>l Heel1]x1 11151 1111 vrtr.:',„ga:rrispartl <0111(11EM 11113 A 1 4/31 fell 114 111e 11910 1111e KO ! r• 1131 014 1011 3*11• 0x1011 < I 111. 1111 Ell 144 K011 2m 190; 1P DAM C41x1** l//' al Hl 13(33334113x11 1 11Y •It Mer W (*2((1)01 I 11/1 •.111 Ell 11911101. 510 40%1J 0114 -Ix -1111 1311 115(1q.33 1101121 rpt 014 tMtk111*01/11. 071111 IxE x(C 1111 20'11141 003111. 1131 W 1111 133. 1 112' R. 135• (12.11 114. (32.11 11. 1/e. / 311 EZ III I pi 10x1 3111 FP? m 1.0111 33( 3) 13 •11041[-111 q• !*3'007 *13)11 r11lM1 • 101 0311 .1. 3 u( M6111�3 031111 (1413 114. 1 111' li 119[1. Ni( 113 1114 II11 14011 1Y1M<1 )/1.311 1x1 11 FON .+,104101 1 *'2 1 0916-11 5811( 0t-06 5:9GLI /ONE ELECTRICAL 151(000281 COOLING NI TH GAS NEAT Packaged Rooftop Builder 1.49f Page 24 of 31 RI - Project: RPI 04/09/201t? Prepared By: 12:25PN Part Number:48KCEA04A2A6-6U0A0 ARI SEER- 14.00 Base Unit Dimensions Unit Length. 74.4 in Unit Width: 46.8 in Unit Height: 33.4 in Operating Weight Base Unit Weight: 490 Ib Medium Heat. 12 Ib Medium Static Option Belt Drive: 10 Ib Temp Ultra Low Leak Economizer w/Baro Relief 50 Ib Total Operating Weight: 562 lb Unit Unit Voltage -Phase -Hertz: 460-3-60 Air Discharge- Vertical Fan Drive Type' Belt Actual Airflow: 1200 CFM Site Attitude. 0 ft Cooling Performance Condenser Entering Air DB: 95.0 F Evaporator Entering Air DB: 80.0 F Evaporator Entering Air WB: 67.0 F Entering Air Enthalpy: 31.44 BTU/Ib Evaporator Leaving Air DB• 59.4 F Evaporator Leaving Air WB: 57.5 F Evaporator Leaving Air Enthalpy: 24.70 BTU/lb Gross Cooling Capacity: 36.41 MBH Gross Sensible Capacity 26.71 MBH Compressor Power Input: 2.95 kW Coil Bypass Factor: 0.113 Heating Performance Heating Airflow: 1200 CFM Entering Air Temp: 70.0 F Leaving Air Temp: 141.8 F Gas Heating Input Capacity: 82.0 / 115.0 MBH Gas Heating Output Capacity: 66.0 / 93.0 MBH Temperature Rise: 71.8 F Thermal Efficiency (%): 80.0 Supply Fan External Static Pressure' 0.50 in wg Options / Accessories Static Pressure Economizer 0.04 in wg Total Application Static (ESP + Unit Opts/Acc.)• 0.54 in wg Fan RPM• 846 Fan Power 0.44 BHP NOTE: Selected IFM RPM Range: 770 -1175 Electrical Data Voltage Range: 414 - 506 Compressor #1 RLA• 5.8 Compressor #1 LRA• 38 Outdoor Fan Motor Qty: Outdoor Fan FLA (ea): 0.5 Packaged Rooftop Builder 1.49f Page 27 of 31 e-1(jr Z \L` --} Tctry t- ; 4r CTJ-11 rLeW L « 5 cu t 127 CP -nom vyw -'-i c v,t5 -r° 0c-rcaC 631(.4X- q = z.4- (74 1►741 5i8a4 o 4(„,,>(oe ) er-Tz-) C31 Jecs . fie per 7, or (h)173 �,3I2 w,' &&Lt ttiu-{i„l '+Yc () f CAT TivIS _f 0uAi c c,r 6 Moore PROJECT: ENGR: j,/...(M P3 / Engineering ' Th—/ kk�ir -! DATE: �-�inieb I/Z5 Group L -D' 2 --1- SCALE: SHEET 12/2/2018 City of Tukwila Department of Community Development KELLY PARFITT 899 W MAIN ST AUBURN, WA 98001 RE: Permit No. M18-0080 RPI 3325 S 116 ST Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 1/6/2019. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. It'd is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 1/6/2019, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, p ey Permit Technician File No: M18-0080 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M18-0080 DATE: 06/19/18 PROJECT NAME: RPI SITE ADDRESS: 3325 S 116 ST X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: kJ t W& t` p`6 Building Division Public Works Ari Aw1 19)646 F Fire Prevention Structural Planning Division nPermit Coordinator El ■ PRELIMINARY REVIEW: Not Applicable ri (no approval/review required) DATE: 06/21/18 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 07/19/18 Approved Corrections Required n Approved with Conditions nDenied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: 12/18/2013 IECS INC 41111114Washington State Department of L)Labor & Industries �\ • Hone Espanol Contact: Safety & Health Claims & Insurance Page 1 of 3 Search L&I A -Z Index Help My L&1 Workplace Rights Trades & Licensing IECS INC Owner or tradesperson Principals HUMPHREY, GEORGE, PRESIDENT Doing business as IECS INC WA UBI No. 601 639 846 PO Box 19252 SEATTLE, WA 98109-1252 206-939-9495 KING County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties HeatingNent/Air-Conditioning and Refrig (HVAC/R) License no. IECS***044QL Effective — expiration 11/13/1996-11/20/2018 Bond No bond accounts during the previous 6 year period. Insurance Nationwide Mutual Ins Co $1,000,000.00 Policy no. ACPACT07555636456 Received by L&I Effective date 08/01/2017 08/01/2017 Expiration date 08/01/2018 Insurance history Savings (in lieu of bond) $6,000.00 Received by L&I Effective date 11/20/2001 11/20/2001 Release date Impaired date N/A N/A Savings account ID 21221204 Savings history Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts Help us improve httns://secure.lni.wa.gov/verify/Detail.aspx?UBI=601639846&LIC=IECS* * *044QL&SAW= 07/10/2018 I• IECS INC No L&I tax debts a..) recorded for this contras 'cense during the previous 6 year period, but some d may be recorded t . other agencies. License Violations No license violatio,.s during the previous 6 year period. Workers' ccmp Do you know if the t usiness has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID 845,304-01 Doing business as SEATTLE MECHA: 'ICAL Estimated workers reported N/A L&I account contact T5 / LADONNA Klf AEY (360)902-4687 - Email: KINL235@Ini.wa.gov Account is closed. Public WorI:s Strikes and Debarments 7 Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have bE :n issued against this contractor. Contractors not al :,wed to bid No debarments ha.. a been issued against this contractor. Workplace 'safety and health Check for any pasti afety and health violations found on jobsites this business was responsible for. Inspection results date 06/14/2016 Violations Inspection no. 317939701 Location 6428 California r ie SW Seattle, WA 981( ) 61 Inspection results date 03/31/2015 Inspection no. 317935645 Location — 13028Interurba. AVE Tukwila, WA 98'.. 8 Inspection results date 04/09/2013 Inspection no. 316583194 Location 940 NE Park Dr Issaquah, WA 9 )29 Inspection results late 12/11/2012 Inspection no 316257716 Location 3325 South 116 Building #2 Seattle, WA 981 3 Violations Violations Violations Page 2 of 3 Help us improve https://secure.lni .va.gov/verify/Detail.aspx?UBI=601639846&LIC=IECS***044QL&SAW= 07/10/2018 IECS INC Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. / \ • Page 3 of 3 Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601639846&LIC=IECS* * *044QL&SAW= 07/10/2018