Loading...
HomeMy WebLinkAboutPermit M18-0087 - NG RESIDENCE - GAS FURNACE REPLACEMENTNG RESIDENCE 3906 S 113T" ST M18-0087 Parcel No: Address: Project Name: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL OTC PERMIT 3351400185 Permit Number: 3906 S 113TH ST NG RESIDENCE Issue Date: Permit Expires On: M18-0087 7/2/2018 12/29/2018 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: TSE WING TSZ+TSE-WONG SIU L 5228 20TH AVE 5 , SEATTLE, WA, 98108 STEVE PEARSON 2264183 AVE S , KENT, WA, 98032 AAA HEATING & AC (CONSTRUCTION) 22641 83RD AVE S , KENT, WA, 98032 AAAHEHA874QM ,Il Phone: (253) 630-9224 Phone: (253) 630-9224 Expiration Date: 11/14/2019 DESCRIPTION OF WORK: LIKE IN KIND GAS FURNACE REPLACEMENT Valuation of Work: $3,000.00 Type of Work: REPLACEMENT Fuel type: GAS Fees Collected: $192.66 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: TUKWILA Sewer District: NONE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: 2015 2015 2015 2015 2015 (dultac National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Date: )-:"(g I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this perm , does of presume to give authority to violate or cancel the provisions of any other state or local laws re • ing coh ruction or the performance of work. I am authorized to sign and obtain this development perm; ;+fid agre tf the conditions attached to this permit. Signature: Print Name: J+`e�!`e� / -e.ocr5 eDi Date: 7/ / This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***MECHANICAL PERMIT CONDITIONS*** 2: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: Manufacturers installation instructions shall be available on the job site at the time of inspection. 5: Except for direct -vent appliances that obtain all combustion air directly from the outdoors; fuel -fired appliances shall not be located in, or obtain combustion air from, any of the following rooms or spaces: Sleeping rooms, bathrooms, toilet rooms, storage closets, surgical rooms. 6: Equipment and appliances having an ignition source and located in hazardous locations and public garages, PRIVATE GARAGES, repair garages, automotive motor -fuel dispensing facilities and parking garages shall be elevated such that the source of ignition is not less than 18 inches above the floor surface on which the equipment or appliance rests. 7: Type 1 Hoods, the required grease duct leakage test and light test shall be performed by a special inspection and testing agency in accordance with I.M.C. Chapter 5. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1800 MECHANICAL FINAL 0701 ROUGH -IN MECHANICAL f \ '\. CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. vt ( Doe 7 Project No. Date Application Accepted: Date Application Expires: (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address: 3906 S 113th St, Tukwila, WA 98168 King Co Assessor's Tax No.: 3351400185 Suite Number: Floor: Tenant Name: PROPERTY OWNER Name: Lewis Ng Address: 22641 83rd Ave S Name: Lewis Ng Address: 3906 S 113th St Contr Reg No.: AAAHEHA874QM Exp Date: 11/14/2019 Address: 3906 S 113th St City: Tukwila State: WA City: Tukwila State: WA Zip: 98168 CONTACT PERSON — person receiving all project communication Name: Lewis Ng Address: 22641 83rd Ave S City: Kent State: WA zip: 98032 Address: 3906 S 113th St Contr Reg No.: AAAHEHA874QM Exp Date: 11/14/2019 Tukwila Business License No.: BUS -0996404 City: Tukwila State: WA Zip: 98168 Phone: (510) 915-0628 Fax: Email: New Tenant: ❑ Yes ..No MECHANICAL CONTRACTOR INFORMATION Company Name: AAA Heating & Air Conditioning Address: 22641 83rd Ave S City: Kent State: WA zip: 98032 Phone: (253) 630-9224 Fax: Contr Reg No.: AAAHEHA874QM Exp Date: 11/14/2019 Tukwila Business License No.: BUS -0996404 Valuation of project (contractor's bid price): $ 3,000 Describe the scope of work in detail: Like in kind gas furnace replacement Use: Residential: New ❑ Replacement ........ Commercial: New ❑ Replacement ❑ Fuel Type: Electric ❑ Gas Other: H:\Applications\Forms-Applications On Line\2016 Applications\Mechanical Permit Application Revised 1-4-16.docx Revised: January 2016 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu 1 Furnace >100k btu Industrial Floor furnace 55 dB(A) Suspended/wall/floor mounted heater 57 dB(A) Appliance vent Commercial Repair or addition to heat/refrig/cooling system 47 dB(A) Air handling unit 65 dB(A) <10,000 cfm 60 dB(A) Unit Type Qty Air handling unit Residential, Nighttime >10,000 cfin Industrial Evaporator cooler 55 dB(A) Ventilation fan connected to single duct 57 dB(A) Ventilation system Commercial Hood and duct 47 dB(A) Incinerator — domestic 65 dB(A) Incinerator — comm/industrial 60 dB(A) Unit Type QtY Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytim A few sounds are exempt from the noise code, including: • Warning devices; • Construction and property maintenance during the daytime hours (7am-10pm); • Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I VE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY B THE WS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWN ' Signature: Print Name: Jc 4'i tSt9V.1, Mailing Address: �� ( C1 3 AV,� AU ORIZED AGENT: S H:WpplicationsTorms-Applications On Line \2016 Applications\Mechanical Permit Application Revised 1-4-16.docx Revised: January 2016 bh Date: ! /z-/18 Day Telephone: 25 3 - 3° - /22`f vt - 11JA• c X0322 City State Zip Page 2 of 2 DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $256.76 EL18-0597 Address: 3906 S 113TH ST Apn: 3351400185 $64.10 ELECTRICAL $61.05 PERMIT FEE SINGLE FAMILY R000.322.101.00.00 0.00 $61.05 TECHNOLOGY FEE $3.05 TECHNOLOGY FEE R000.322.900.04.00 0.00 $3.05 M18-0087 Address: 3906 S 113TH ST Apn: 3351400185 $192.66 MECHANICAL $183.49 PERMIT FEE R000.322.100.00.00 0.00 $150.34 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 TECHNOLOGY FEE $9.17 TECHNOLOGY FEE R000.322.900.04.00 0.00 $9.17 TOTAL FEES PAID BY. RECEIPT: R14850 $256.76 Date Paid: Monday, July 02, 2018 Paid By: AAA HEATING & AC Pay Method: CHECK 5131 Printed: Monday, July 02, 2018 1:43 PM 1 of 1 SYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 /'918- 6087 Project: A/6-R��S/2F�l/t� Type of Inspection: nizemaenz. i% -i- Address: 3901' S . //5m' 5 '7 Date Called: Special Instructions: Date Wanted: 9 //-15---/ / a.m. p.m. Requester: Phone No: 5/D -f-0628 Approved per applicable codes. Corrections required prior to approval. COMMENTS: ANAL_ Inspector: Date: ././...../5„.:_y? r�!�i c/�_ / G n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 i� a'& Project: Type of Inspection: Address:`/ 3q0&.S / 13zff- sr Date Called: Special Instructions: (/--/1/49 Date Wanted: a.m. Requester: ACL)/S Phone No: 170 ?/5—e‘z5 Approved per applicable codes. orrections required prior to approval. COMMENTS: -00 P,, vAk Inspector: Date: 7/1 n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit Re 15087 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Probe Type of Inspection: Address: Date Called: Special Instructions: �,�� lJC mr� s d' I O tr '/ l,, Date Wanted: /Z– 5 -- a.m. p.m. Requester: Phone No: Po 913- obze ElApprovedper applicable codes. Corrections required prior to approval. COMMENTS: 4i��,� `fes "�4r S ait.e6a —4.1-;g5A I CaliYeri( )4-014rne >C% -k► . Inspector: cc/ Date: /Zz,c9/C7 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 10/1/2019 STEVE PEARSON 22641 83 AVE S KENT, WA 98032 ( City of Tukwila Department of Community Development RE: Permit No. M18-0087 NG RESIDENCE 3906 S 113 ST Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the Issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 11/27/2019. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or fmal inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 11/27/2019, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Bill Rambo Permit Technician File No: M18-0087 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 5/2/2019 STEVE PEARSON 22641 83 AVE S KENT, WA 98032 f City of Tukwila Department of Community Development RE: Permit No. M18-0087 NG RESIDENCE 3906 S 113 ST Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 6/3/2019. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 6/3/2019, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, ndace Nichols Permit Technician File No: M18-0087 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 11/1/2018 STEVE PEARSON 22641 83 AVE S KENT, WA 98032 7. 1 i City of Tukwila Department of Community Development RE: Permit No. M18-0087 NG RESIDENCE 3906 S 113 ST Dear Permit Holder: 1 J Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 12/29/2018. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 12/29/2018, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, 'LA--.k( Bill Rambo Permit Technician File No: M18-0087 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 AAA Heating & AC Horne Espahol Contact Safety & Health Washington State Department of Labor & industries Claims & Insurance Search L&I A -L Index Help Workplace Rights AAA Heating & AC Owner or tradesperson Principals Cartwright, Shaun P, PRESIDENT Kowalenko, Victor, VICE PRESIDENT Doing business as AAA Heating & AC WA UBI No. 601 882 148 Parent company AAA HTG REFRIGERATION INC 22641 83RD AVE S KENT, WA 98032-1990 253-630-9224 KING County Business type Corporation Governing persons VICTOR KOWALENKO JAN ANGELA KOWALENKO; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. ........................._.._................ Meets current requirements. License specialties GENERAL License no. AAAHEHA874QM Effective — expiration 11/14/2013-11/14/2019 Bond Cincinnati Ins Co Bond account no. 0552591 Received by L&I 11/14/2013 Insurance ............... Nationwide Mutual Ins Co Policy no. ACPGLD0750825039 Received by L&I 10/10/2017 Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings $12,000.00 Effective date 10/18/2013 Expiration date Until Canceled $1,000,000.00 Effective date 11/01/2013 Expiration date 11/01/2018 Page 1 of 2 1, 4. t. My L&I Trades & Licensing Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601882148&LIC=AAAHEHA874QM&SAW= 7/2/2018 AAA Heating & AC No lawsuits against the bond or savings acts ''s during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID Account is current. 932,553-01 Doing business as AAA HEATING & AIR CONDITIONING Estimated workers reported Quarter 1 of Year 2018 "21 to 30 Workers" L&I account contact T1 / IDA HAYNES (360)902-5635 - Email: HAYN235@lni.wa.gov Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health No inspections during the previous 6 year period. Page 2 of 2 P. Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601882148&LIC=AAAHEHA874QM&SAW= 7/2/2018