Loading...
HomeMy WebLinkAboutPermit M18-0092 - WALKING CO - AIR HANDLER AND OUTDOOR UNIT REPLACEMENTWALKING CO 122 SOUTHCENTER MALL EXPIRED 02/26/19 MI 8-0092 Parcel No: Address: / \ City of Tukwila / •\ Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 9202470130 Permit Number: 122 SOUTHCENTER MALL Project Name: WALKING CO Issue Date: Permit Expires On: M 18-0092 8/30/2018 2/26/2019 Owner: Name: Address: , , ID, Contact Person: Name: TOM PATTERSON Address: 1712 S ROOSEVELT ST , BOISE, ID, 83705 Contractor: Name: TOTAL SYSTEM SERVICES INC Address: PO BOX 2091, BOISE, ID, 83701 License No: TOTALSS922L6 Lender: Name: Address: Phone: (208) 789-4772 Phone: (208) 376-1393 Expiration Date: 6/26/2020 DESCRIPTION OF WORK: REPLACE AIR HANDLER AND OUTDOOR UNIT Valuation of Work: $20,000.00 Type of Work: REPLACEMENT Fuel type: ELECT Fees Collected: $477.93 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Permit Center Authorized Signature: Date: 0({,30/7e- / • I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit a .d agree tot► - ditions attached to this permit. •Signature: •g /� Print Name: TO VII 10,1kaati Date: g This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: Readily accessible access to roof mounted equipment is required. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: ***MECHANICAL PERMIT CONDITIONS*** 10: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 11: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL l , CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov l'\ Mechanical Permit No. M11(6/ Project No. Date Application Accepted: Date Application Expires: 1 (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION c ) / King Co Assessor's Tax No.: Site Address: ! Si4'k\ .6m Cj, I, I Suite Number: Floor: 1 Tenant Name: cv PROPERTY OWNER Name: R# � er soil j Name: Address: Address: Se V e 1� Address: Phoneag,"7j�(, Lrfl1Fax: k'( Email: City: State: Zip: CONTACT PERSON — person receiving all project communication Name: R# � er soil j ! Address: Address: Se V e 1� City: State: Zip: Phoneag,"7j�(, Lrfl1Fax: k'( Email: New Tenant: ❑ Yes MECHANICAL CONTRACTOR INFORMATION Company Name: Ti51c1 /a, eiII C& `. Address: Se V e 1� 5‘" Zip t� City: 130ise State: '74�'b IJ Phone: DA "� ', 1 Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: 5 a }/ Valuation of project (contractor's bid price): $ � 006 — D O Ieje 4lr e,w o(-1,-cL°Dr CAA' Describe the scope of work in detail: Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement Fuel Type: Electric Gas ❑ Other: H: Applications\Forms-Applications On Line\2016 Applications\Mechanical Permit Application Revised 1-4-16.docx Revised: January 2016 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Residential, Nighttime Furnace >100k btu Industrial Floor furnace 55 dB(A) Suspended/wall/floor mounted heater 57 dB(A) Appliance vent Commercial Repair or addition to heat/refrig/cooling system 47 dB(A) Incinerator — domestic Air handling unit Incinerator — comm/industrial <10,000 cfm ' Unit Type Qty Air handling unit Residential, Nighttime >10,000 cfin Industrial Evaporator cooler 55 dB(A) Ventilation fan connected to single duct 57 dB(A) Ventilation system Commercial Hood and duct 47 dB(A) Incinerator — domestic 65 dB(A) Incinerator — comm/industrial 60 dB(A) Unit Type Qty Fire damper Residential, Nighttime Diffuser Industrial Thermostat 55 dB(A) Wood/gas stove 57 dB(A) Emergency generator Commercial Other mechanical equipment 47 dB(A) 60 dB(A) 65 dB(A) Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-1 OPM, Monday through Friday and 8AM-10PM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: • Warning devices; • Construction and property maintenance during the daytime hours (lam- l Opm); • Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name: i —1;1^11 Pc146"Seh Mailing Address: 17 1 a SRposve) .- H:Wpplications\Forms-Applications On Line\2016 Applications\Mechanical Permit Application Revised 1-4-16.docx Revised: January 2016 bh Day Telephone: City Date:_(— a0<g--iget- L/77A State Zip Page 2 of 2 l ti DESCRIPTIONS ( ACCOUNT QUA TITY PAID $477.93 PermitTRAK M18-0092 Address: 122 SOUTHCENTER MALL Apn: 9202470130 $477.93 Credit Card Fee $13.92 Credit Card Fee R000,369.908.00.00 0.00 $13.92 MECHANICAL $446.16 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $323.78 PLAN CHECK FEE R000.322,102.00.00 0.00 $89.23 TECHNOLOGY FEE $17.85 TECHNOLOGY FEE R000.322,900.04.00 0.00 $17.85 $477.93 TOTAL FEES PAID BY RECEIPT: R14963 Date Paid: Monday, July 16, 2018 Paid By: TOTAL SYSTEM Pay Method: CREDIT CARD 00570G Printed: Monday, July 16, 2018 3:48 PM 1 of 1 SYSTEMS Page 1 of 2 CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA 0017340000802374464500 Date: 07/16/2018 03:48:12 PM CREDIT CARD SALE VISA CARD NUMBER: **********6369 K TRAN AMOUNT: $477.93 APPROVAL CD: 00570G RECORD #: 000 CLERK ID: Rachelle X {CARDHOLDER'S SIGNATURE} I AGREE TO PAY THE ABOVE TOTAL AMOUNT ACCORDING TO THE CARD ISSUER AGREEMENT (MERCHANT AGREEMENT IF CREDIT VOUCHER) Thank you! Merchant Copy https://classic. convergepay. com/V irtualMerchant/transaction. do?dispatchMethod=printTra... 7/16/2018 Page 2 of 2 CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA Date: 07/16/2018 03:48:12 PM CREDIT CARD SALE VISA CARD NUMBER: **********6369 K TRAN AMOUNT: $477.93 APPROVAL CD: 00570G RECORD #: 000 CLERK ID: Rachelle Thank you! Customer Copy https://classic.convergepay.com/VirtualMerchant/transaction.do?dispatchMethod=printTra... 7/16/2018 GO g e Maps Southcenter iQTBergman Luggage QThe Art of Shaving rREVISION S No changes shall bt riFtde to the scoop of work witho; t prior approval of Ttuim la B.,:ld ng Division NOTE: F-rsihns wiil roquire a In,^:v plan submittal and may i.1:-;ida add:tional plan ri,-.trr tc,= LUSH 9 I.4......„, V The Walking Compary - Westfield Southcenter SLt'A". L ;iT Mechanical Electrical ,,,Plumbing Lid Gas Piping City of Tukwila BUILDING DIVISION QVerizon - /fir Go g!e Sc-oPolAe4 ELE Perm!t O. r10SOU 1,`' Plan reviaw approval i3 subject to crrors and omissions. Approval of construction documents docs nct authorize the violation of any adopted coda or ordnance. Rsccipt of approved Field Copy and conditions is aclz ;cwl ;dyad. By: 2-30-15 Date: City of Tu • w;!a BUILDiNS c;VISION Bath & Body Work Map data ©2018 Goggle 10 ft Lolls and Pops REVIEWED FOR CODE COMPLIANCE APPROVED JUL 2 5 201 • k\1 City of Tukwila BUILDING DIVISION Locikk. Ne:0 RECEIVED CITY OF TUKWILA JUL 1 6 2018 PERMIT CENTER ItJJtc6/ 00V, "2119.1111 CERTIFIED° www.ahridirectory.org This combination qualifies for a Federal Energy Efficiency tax Credit when placed in service between Feb 17,2009 and Dec 31, 2016. Certificate of Product Ratings AHRI Certified Reference Number : 9141025 Date : 07-16-2018 AHRI Type : HRCU-A-CB Series : XR17 Outdoor Unit Brand Name : TRANE Outdoor Unit Model Number (Condenser or Single Package) : 4TWA7060A3 Indoor Unit Model Number (Evaporator and/or Air Handler) : TEM6A0C60H51+TDR+UF/HRZ The manufacturer of this TRANE product is responsible for the rating of this system combination. Model Status : Active Rated as follows in accordance with the latest edition of ANSI/AHRI 210/240 with Addenda 1 and 2, Performance Rating of Unitary Air -Conditioning & Air -Source Heat Pump Equipment and subject to rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity (A2) - Single or High Stage (95F), btuh : 56000 SEER : 16.50 EER (A2) - Single or High Stage (95F) : 12.50 Heating Capacity (H12) - Single or High Stage (47F) : 55000 HSPF (Region IV) : 9.50 E-FREN-hEWED FOR CODE COMPLIANCE APPROVED JUL 252018 City of Tukwila RECEIVED CITY OF TUKWILA JUL 162018 PERMIT CENTER t"Active" Model Status are those that an AHRI Certification f13eMfIVIPrvaucN ND selling or offering for sale; OR new models that are being marketed but are not yet being produced."Production Stopp-. ..e a us are i ose a a - - -rtification Program Participant is no longer producing BUT is still selling or offering for sale. Ratings that are accompanied by WAS indicate an involuntary re -rate. The new published rating is shown along with the previous (Le. WAS) rating. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed In the directory at www.ahrldirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and confidential reference purposes. The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated; entered into a computer database; or otherwise utilized, In any form or manner or by any means, except for the user's individual, personal and confidential reference. CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified at www.ahrldlrectory.org, click on "Verify Certificate" link and enter the AHRI Certified Reference Number and the date on which the certificate was Issued, which is listed above, and the Certificate No., which Is listed at bottom right. ©2018Air-Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: AIR-CONDITIONING, HEATING, & REFRIGERATION INSTITUTE we make life better" 131762301642514684 • Go g[¢ Maps Bergman Luggage Shaving e Westfield WIRN alking ®ompa y Southcenter n Michael Bauer GOO le XFIN I.T.Y_Store.by Gomcas,Direc{�DeaIe Imagery ©2018 Google, Map data ©2018 Google 20 ft Noafrotv4., 4Cd- OcvW Joar WVl?�" kBte RECEIVED CITY OF TUKWILA JUL 1 6 2018 REVIEWED FO CODE COMPLIANCE APPROVED JUL 2 5 2018 City of Tukwila BUILDING DIVISION MB/ 00 Go g e Maps Bergman Luggage Shaving MetroPCS he Walking company Sout center Sunglass, ut X IIN TYStoreby' ..(Westfie dcSo thcenter Comcast Direct Dealer A SO -pt Center Jamba tceageolg7M) • a SKESHERS R Imagery ©2018 Google, Map data ©2018 Google 50 ft RECEIVED CITY CF TUKWILA JUL 1 6 2018 REVI -11:1 ki q CODE COMPLIANCE APPROVED JUL 2 5 2E18 City of Tukwila BUILDING DIVISION MV' OO'L ER 1/2/2019 City of Tukwila Department of Community Development TOM PATTERSON 1712 S ROOSEVELT ST BOISE, ID 83705 RE: Permit No. M18-0092 WALKING CO 122 SOUTHCENTER MALL Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 2/26/2019. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 2/26/2019, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: M18-0092 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 (7ERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M18-0092 DATE: 07/18/18 PROJECT NAME: WALKING CO SITE ADDRESS: 122 SOUTHCENTER MALL X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: Pry V) V\K Building Division Public Works Fire Prevention O Planning Division ❑ Structural ❑ Permit Coordinator PRELIMINARY REVIEW: DATE: 07/19/18 Not Applicable ❑ Structural Review Required (no approval/review required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required ❑ Approved with Conditions ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) DUE DATE: 08/17/18 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: 12/18/2013 TOTAL SYSTEM SERVICES INC, Washington State Department of Labor & Industries • 11ome Espanol Contact Safety & Health Claims & Insurance F - [Search L&I Page 1 of 2 A -Z Index Help My I & Workplace Rights Trades & Licensing TOTAL SYSTEM SERVICES INC Owner or tradesperson Principals LUKES, MICHAEL A, PRESIDENT MILLER, STEVEN J, VICE PRESIDENT C T CORPORATION SYSTEM, AGENT Doing business as TOTAL SYSTEM SERVICES INC WA UBI No. 601 309 438 PO BOX 2091 BOISE, ID 83701 208-376-1393 Business type Corporation Governing persons DENNIS A GRATTON MICHAEL J WHITE; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties HeatingNent/Air-Conditioning and Refrig (HVAC/R) License no. TOTALSS922L6 Effective — expiration 06/26/2008— 06/26/2020 Bond LIBERTY MUTUAL INS CO Bond account no. 965009416 Active. Meets current requirements. $6,000.00 Received by L&I Effective date 06/26/2008 06/19/2008 Expiration date Until Canceled Insurance EMCASCO INSURANCE COMPANY Policy no. 5D80925 $1,000,000.00 Received by L&I Effective date 01/08/2018 01/01/2018 Expiration date 01/01/2019 Insurance history Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601309438&LIC=TOTALSS922L6&SAW= 8/30/2018