Permit M18-0093 - RELIABLE PARTS - ROOFTOP HEAT PUMP REPLACEMENT
RELIABLE PARTS 1051 ANDOVER PARK W MI 8-0093 Parcel No: Address: \ City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.Kov MECHANICAL PERMIT 2623049122 Permit Number: M18-0093 1051 ANDOVER PARK W BLDG Issue Date: 8/1/2018 Permit Expires On: 1/28/2019 Project Name: RELIABLE PARTS Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: MVI TUKWILA 1 LLC 1003 LAKE S #301, KIRKLAND, WA, 98033 DAVE ANDRINGA 1402 MAPLE AVE SW , RENTON, WA, 98057 SEA AIRE INC (GENERAL) 1402 MAPLE AVE SW , RENTON, WA, 98057 SEAAII*206JQ /11 Phone: (206) 779-6636 Phone: (206) 575-8051 Expiration Date: 5/4/2020 DESCRIPTION OF WORK: REPLACE 4 TON ROOFTOP HEAT -PUMP WITH 4 TON HEAT -PUMP. NEW UNIT WEIGHT LESS. TIE INTO EXISTING ROOFTOP DUCTWORK. UNIT LESS THAN 2000 CFM Valuation of Work: $12,100.00 Type of Work: REPLACEMENT Fuel type: ELECT Fees Collected: $381.86 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: 2015 2015 2015 2015 2015 kk National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Date:"' 1 "( U I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development ermit and agree toothe conditions attached to this permit. Signature: C -&"Q ""` L- Date: - J8 Print Name: ( Prue yd f t This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: Readily accessible access to roof mounted equipment is required. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: ***MECHANICAL PERMIT CONDITIONS*** 10: All mechanical work shall be inspected and approved under Permit Center (206/431-3670). 11: Manufacturers installation instructions shall be available on PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 0703 1800 0705 0701 MECH EQUIP EFF MECHANICAL FINAL REFRIGERATION EQUIP ROUGH -IN MECHANICAL a separate permit the job site at the issued by the City of Tukwila time of inspection. CITY OF TUKWIt. Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. ti 1 6- 00 q Project No. Date Application Accepted: / --4$---(5 HO -(1 Date Application Expires: (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION C36 is otj? a� Fr Str ✓ems /via r rt Site Address: o 57 / /1( cJ e,r ()r 1 �L/ Tenant Name: Pe. ! l 4 k IP, P/4 Os PROPERTY OWNER Name: zy• jf }vmeterie l,i Address: 300 -7 :it,I, S {k -r P 4- R ti, N6 City: 5,4'..e State: Zip: CONTACT PERSON — person receiving all project communication Name:A /ifi N� Aelrlri fly et— Address: l4C2_ /'14 -/Ir- 19.E .c" La City:State: Zip: , c n tJA- qP. e S 7 Phon Fax: ��tai 7l i -x; ,36 Email: I3Ave_, A (. s t-atrc. C lltiIs,ess�FFr L� /✓o; .t -i. si g. King Co Assessor's Tax No.: 24413 3 O `>< - ?t Z 2 - Suite Suite Number: Floor: New Tenant: ❑ Yes IR No MECHANICAL CONTRACTOR INFORMATION Company Name: Address: No kJ. ti City: er)ii,State: Zip: Phone:(ze 9 7 79 63 Fay:: Contr Reg No.: rG/1/jExp Date: S.1 L11�tT s Lt ` r ! Tukwila Business License No.:3“ S _ woo 3 Valuation of project (contractor's bid price): $ 12%, / 0 0 Describe the scope of work in detail: Fe P j..c 4/ itcti (acs %CP 1'► 1.44 1'( 4cri (CeF•Ap keA1L Ate L.) cm l`' vt14;,gj. S 1 esS 'T E isi 6 C-)ciS7"r raoFivp elvc.FLA/ ark_ /i.f /e Mar^ Zv c. C F.4 -L Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement Lel Fuel Type: Electric ly Gas ❑ Other: H:\Applications\Forms-Applications On Line'Q016 Applications \Mechanical Permit Application Revised 1-4-16.docx Revised: January 2016 hh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Residential, Nighttime Furnace >100k btu Industrial Floor furnace 55 dB(A) Suspended/wall/floor mounted heater 57 dB(A) Appliance vent Commercial Repair or addition to heat/refrig/cooling system 47 dB(A) Air handling unit 65 dB(A) <10,000 cfm 60 dB(A) Unit Type Qty Air handling unit Residential, Nighttime >10,000 cfm Industrial Evaporator cooler 55 dB(A) Ventilation fan connected to single duct 57 dB(A) Ventilation system Commercial Hood and duct 47 dB(A) Incinerator — domestic 65 dB(A) Incinerator — comm/industrial 60 dB(A) Unit Type Qty Fire damper Residential, Nighttime Diffuser Industrial Thermostat 55 dB(A) Wood/gas stove 57 dB(A) Emergency generator Commercial Other mechanical equipment 47 dB(A) 60 dB(A) 65 dB(A) Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 *Daytim District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) A few sounds are exempt from the noise code, including: • Warning devices; • Construction and property maintenance during the daytime hours (7am-lOpm); • Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: �.J &L.4.) -(Z, ail 4,,,,,.,,' . Date: 7 - l 8 --i O Q Print Name: J e /4-✓ICLr, ,.L y c,_ Day Telephone: (0c -4.7j 7 79 -1-6 St; Mailing Address: /40 L MAI) J 44 .i -J e..44 ") •.. um- 90 Ci 5 7 City State Zip H:\Applications\porno-Applications On Line \2016 Applications\Mechanical Permit Application Revised 1-4-16.docx Revised: January 2016 bh Page 2 of 2 / DESCRIPTIONS ACCOUNT QUA TITY PAID $381.86 PermitTRAK M18-0093 Address: 1051 ANDOVER PARK W BLDG Apn: 2623049122 $381.86 Credit Card Fee $11.12 Credit Card Fee R000.369.908.00.00 0.00 $11.12 MECHANICAL $356.48 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $252.03 PLAN CHECK FEE R000.322.102.00.00 0.00 $71.30 TECHNOLOGY FEE $14.26 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R14977 R000.322.900.04.00 0.00 $14.26 $381.86 Date Paid: Wednesday, July 18, 2018 Paid By: DAVID ANDRINGA Pay Method: CREDIT CARD 06917C Printed: Wednesday, July 18, 2018 2:03 PM 1 of 1 SYSTEMS Page 1 of 2 CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA 0017340000802374464500 Date: 07/18/2018 02:02:47 PM CREDIT CARD SALE MASTERCARD CARD NUMBER: **********0760 K TRAN AMOUNT: $381.86 APPROVAL CD: 06917C RECORD #: 000 CLERK ID: Bill X (CARDHOLDER'S SIGNATURE) I AGREE TO PAY THE ABOVE TOTAL AMOUNT ACCORDING TO THE CARD ISSUER AGREEMENT (MERCHANT AGREEMENT IF CREDIT VOUCHER) Thank you! Merchant Copy https://classic.convergepay.com/V irtualMerchant/transaction.do?dispatchMethod=printTra... 7/1 8/20 1 8 INSPECTION NO. INSPECTION RECORD Retain a copy with permit ccfl3 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION )\2/4) G 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit inspection Request Line (206) 438-9350 Project: E L AgL Type of Inspection: mv.c.4440-4 Gam- -75.4t. Addres : 1 ac 1 A,Jrk?J M (L Date Called: W rr p.m.'". Special Instructions: `— 101;670 A' i' `a CAA k' ' A Date Wanted: ^�3-i9 Requester: \^' OA, Phone No: 24(,' 116t l 3IQ pproved per applicable codes. ® Corrections required prior to approval. OMMENTS: Inspector: ri REINSPECTIdN FE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit ft h,$ 007 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: Address: iof7 4,0247-1 filiftg- b/ Date Called: a.rry p.m. Special Instructions: 9 c ✓' f f J 9 _ CAyr_ *ktD Date Wanted: /2 -17 -18 Requester: 3446 Phone No: Zor. "714 (ob3(o ElApproved per applicable codes. Corrections required prior to approval. P&ee)e_ addpeiS . I'2yC1-G/ TC_ ,1144, REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Rte-. - T� �--Nof ggA. Description of work: Reliable Parts • Replace 4 Ton rooftop heat pump with 4 ton heat pump • Set on sleepers, Anchor per Seismic hold down details • Tile into existing rooftop duct work, no modifications to duct work in space • Include economizer. Unit is under 2000CFM • Old unit weighs 5501bs. New unit weighs 4711its copy Pernefft No. MIK/00 °I/7 Plan review epprc :1 is subject to errors and omissions. Approval of ccnstr €: t:on documents docsi is cU thorize the violation of any adopted coda or ordinzro. Rcpt of approved Field Copy and condi�ions is €c:�now:cdred: By: l- c VICINITY MAP NOT TO SCALE (NORTH UP) M110(LER BLVD L_ II �I TRILAND DR _S 1 SOT_ H ST R JE ate: City of Tuk t ' LOCATION BUILDING DIV SION itarkm 1 1T.x. 43E 1 R %tisTKAZtptLo. / 4c4 13,V.4-2 4:1c4'AV 41Z elk $544.1We, tt 10 �. Ca' t SOC -1-4 e ■... . Oaf • No changes shall be made to the scope 4319 t Of work without prior approval of 1 .4( Tul;wila NOTE: Revi. !ens wi and may in ;lude It ❑ P, c:han;cal 9U Elcctncal ,1.�, lumbing ID/Gas Piping City of Tukwila BUILDrG DIVISION REVISIONS RE -VIEWED F CODE COMPLIA APPROVED JUL 2 2018 City of of Tu BUILDIRIQQA s T SPACE Bg Division e a new plan submitta► gfrO plan review fees ; PARCEL 90 • Reel a rKe V«iiT /O' Easr of RooF atat REVIEWED FOR CODE COMPLIANCE APPROVED ,. City of Tukwila I 6iMI ON ;3" CA z 0 Ne F- CC 0 Z IL C Wa 0 0< z� 17). o� r 1 RECNIVED OVEY ViiitVilLA JUL 18 2018 PERE't'a CEDI'ER f HVAC Equipment Schedule Unit # Brand Name Model # Nominal Tonnage Total CFM OSA CFM ECON Cycle SP HP/ BHP COOLING HEATING LWA Weight (lbs)2 Location Service Total (BTUH) Sensible (BTUH) SEER/ . EER IPLV BTU/ ft.2 Input (BTUH) Output (BTUH) COP/HSPF Comb. Eff./ AFUE BTU/ ft,2 1 -.-ager ICccd loo ol p � 3 .-,0 �l�sep a, s" Q LH/5-00 ,�ls'PF `i 7i yet IRs" ,, 4 Ton Convertible Heat Pump Packaged Units PRODUCT SPECIFICATIONS M deL 4WCZ6048A4000A MODEL RATED Volts/PH/Hz Performance Cooling BTUH (High) Indoor Airflow (CFM) Power Input (KW) BTUH (Low) Indoor Airflow (CFM) Power Input (KW) EER - HI / LOW / SEER Sound Rating No.0 4WCZ6048A4000A 460/3/60 47500 1575 3.26 34500 1150 2.58 12.0/13.6/16.0 71 Performance Heating0 (High Temp.)BTUH / COP Power Input (KW) (Low Temp.) BTUH / COP Power Input (KW) (High Temp.)BTUH / COP Power Input (KW) (Low Temp.) BTUH / COP Power Input (KW) HSPF (BTU / Watt -Hr.)© (High) (High) (Low) (Low) 44500 / 4.0 3.26 27000 / 2.67 2.96 32400 / 4.0 2.37 18500 / 2.42 2.24 9.0 POWER CONN.-V/Ph/Hz Min. Brch. Cir. Ampacity© Fuse Size - Max. / Recmd. (amps) 460/3/60 15.3 20 / 20 COMPRESSOR Volts/Ph/Hz R.L. Amps - L.R. Amps 2 -STAGE SCROLL 460/3/60 6.4 / 41.0 OUTDOOR COIL - TYPE Rows/F.P.I. Face Area (sq.ft.) Tube Size (in.) Refrigerant Control INDOOR COIL - TYPE Rows/F.P.I. Face Area (sq.ft.) Tube Size (in.) Refrigerant Control Drain Conn. Size (in.) SPINE -FIN 2/24 23.57 3/8 EXPANSION VALVE PLATE -FIN 4/15 5.0 3/8 EXPANSION VALVE 3/4 FEMALE NPT OUTDOOR FAN - TYPE Dia. (in.) Drive/No. Speeds CFM @ 0.0 in. w.g.® Motor - HP/R.P.M. Volts/Ph/Hz F.L. Amps/L.R. Amos PROPELLER 28.2 DIRECT / 1 4200 1/6 / 830 460/1/60 0.5 / 0.84 INDOOR FAN - TYPE ,r Dia x Width (in.) Drive/No. Speeds CFM @ 0.0 in. w.g.0 Motor - HP/R.P.M. Volts/Ph/Hz F.L. Amps/L.R. Amps CENTRIFUGAL 10 X 10 DIRECT / VARIABLE SEE FAN PERFORMANCE TABLE 3/4 / VARIABLE 208-230/1/60 6.8 / 6.8 FILTER / FURNISHED Type Recommended Recmd. Face Area (sq. ft.)O NO THROWAWAY 5.3 REFRIGERANT / Charge (lbs.) R410A / 8.8 DIMENSIONS Crated (in.) WEIGHT / Shipping / Net (lbs.) HXWXL 52.0/47.0/62.0 607 / 479 k„ 71rn COND/T/ON/NG REVIEWED FOR CODE COMPLIANCE APPROVED JUL 2 5 2018 City of Tukwila BUILDING DIVISION TAG: SUBMITTAL/SELECTION COMBINATION HEATING/COOLING ROOFTOP AIR CONDITIONER 21/2-4 Tons SFHC SFHC QS/S-1 DATE JUNE, 1980 SUPERSEDES Supplement to SFHA QS/S-1 11/79 NOMINAL TONNAGE 025 = 2.5 030 = 3.0 035 = 3.5 040 = 4.0 VOLTAGE ❑1 = 208-230/60/1 03 = 208-240/60/3 04 = 440-480/60/3 HEATING INPUT CAPACITY ❑L = Low Heat ❑H = High Heat FIGURE A SFHC 25-30, 35-40 Unit Dimensions Yi N.P.T. \ R \\i DRAIN CONN. PIPE SUPPORTS FURNISHED BY OTHERS SFHC 25-30 35-40 L 5674 7014 W 323/4 3814 A 231 27 8 16 2339 C 1414 1414 Net Wet. 445 550 CM OF YUCZC'LQ JUL 18 2018 PERM' CENYER 5-3-0 /As `f'14 /S s TAG: L-6 Pane A/R COND/T/ON/NG SUBMITTAL/SELECTION COMBINATION HEATING/COOLING ROOFTOP AIR CONDITIONER 21/2-4 Tons SFHC NOMINAL TONNAGE VOLTAGE 1:11 = 208-230/60/1 ❑3 = 208-240/60/3 04 = 440-480/60/3 ❑25 = 2.5 ❑30 = 3.0 ❑35 = 3.5 ❑40 = 4.0 t•1uuHt A SFHC 25-30, 35-40 Unit Dimensions L SFHC QS/S-1 DATE JUNE, 1980 SUPERSEDES Supplement to SFHA QS/S-1 11/79 HEATING INPUT CAPACITY ❑L = Low Heat ❑H = High Heat w 13i a: N.P.T. DRAIN. CONN. PIPE SUPPORTS FURNISHED BY OTHERS SFHC 25-30 35-40 L 587/e 701/4 W 321/4 381/4 A 231/4 P7 B 16 234'4 C 141/4 141/4 Net Wet. 445 550 FIGURE 8 Supply - Return Casing Dimensions .o REVIEW SFHC 25-30 ODE CC L 43Y 57 W 3644 c APF 0244 I�IaPF A 473/4 Net Wt. 180 225 FicuPF r. iuL Outside Air & Economizer Intake Hood SFHC 25-30 35-40^i�/ L 34 �r 473811 `7 of O.A. Net Wt. 56 BUILDIN •' Econ. Net. Wt. 92 –Mu B RE D — Roof Curb SFHC 25-30 35-40 L414% 211/2 551/8 W 363/4 423/4 A 49% 631/2 B 2848 3434 Net Wt. 56 74 FIGURE E — enneantrie newt SFHC 25-30 35-40 L . 211/2 271/e W 21 27 A 15 18 B 15 18 Net Wt. 60 © THE TRANE COMPANY, 1980 M5 16Ye MOUNTING HOLES %z DIA, (4) 2 x 2 NAILING STRIP MP OVED 5 2018 'ukwila DIVISION,. AA 60 00q3 RECEIVED CITY OF TUKWILA JUL 18 2018 TRANE TAG: 14-€ l211 4WCZ6048-SU B-4 SUBMITTAL 4 Ton Convertible Heat Pump Packaged Units 4WCZ6048A4000A PRODUCT SPECIFICATIONS MODEL RATED Volts/PH/Hz Performance Cooling BTUH (High) Indoor Airflow (CFM) Power Input (KW) BTUH (Low) Indoor Airflow (CFM) Power Input (KW) EER - HI / LOW / SEER Sound Rating No.® 4WCZ6048A4000A 460/3/60 47500 1575 3.26 34500 1150 2.58 12.0/13.6/16.0 71 Performance Heating@ (High Temp.)BTUH / COP (High) Power Input (KW) (Low Temp.) BTUH / COP (High) Power Input (KW) (High Temp.)BTUH / COP (Low) Power Input (KW) (Low Temp.) BTUH / COP (Low) Power Input (KW) HSPF (BTU / Watt -Hr.)® 44500 / 4.0 3.26 27000 / 2.67 2.96 32400 / 4.0 2.37 18500 / 2.42 2.24 9.0 POWER CONN.—V/Ph/Hz Min. Brch. Cir. Ampacity® Fuse Size — Max. / Recmd. (amps) 460/3/60 15.3 20 / 20 COMPRESSOR Volts/Ph/Hz R.L. Amps — L.R. Amps 2 -STAGE SCROLL 460/3/60 6.4 / 41.0 OUTDOOR COIL — TYPE Rows/F.P.I. Face Area (sq.ft.) Tube Size (in.) Refrigerant Control INDOOR COIL — TYPE Rows/F.P.i. Face Area (sq.ft.) Tube Size (in.) Refrigerant Control Drain Conn. Size (in.) SPINE -FIN 2/24 23.57 3/8 EXPANSION VALVE PLATE FIN 4/15 5.0 3/8 EXPANSION VALVE 3/4 FEMALE NPT OUTDOOR FAN — TYPE Dia. (in.) Drive/No. Speeds CFM @ 0.0 in. w.g.® Motor— HP/R.P.M. Volts/Ph/Hz F.L. Amps/L.R. Amps PROPELLER 28.2 DIRECT / 1 4200 1/6 / 830 460/1/60 0.5 / 0.84 INDOOR FAN — TYPE Dia x Width (in.) Drive/No. Speeds CFM @ 0.0 in. w.g.0 Motor— HP/R.P.M. Volts/Ph/Hz F.L. Amps/L.R. Amps FILTER / FURNISHED Type Recommended Recmd. Face Area (sq. ft.)® CENTRIFUGAL 10 X 10 DIRECT / VARIABLE SEE FAN PERFORMANCE TABLE 3/4 / VARIABLE 208-230/1/60 6.8 / 6.8 NO THROWAWAY 5.3 REFRIGERANT / Charge (lbs.) R410A / 8.8 DIMENSIONS Crated (in.) WEIGHT/ Shipping / Net (lbs.) HXWXL 52.0/47.0/62.0 607 / 479 © 2007 American Standard Inc. All Rights Reserved O Certified in accordance with the Unitary Air -Conditioner Equipment certification program, which is based on ARI Standard 210/240. 0 Calculated in accordance with A.R.I. Standard 270. 0 Calculated in accordance with currently prevailing Nat'l Electrical Code. 0 Standard Air — Dry Coil — Outdoor. 0 Standard Air — Wet Coil — Indoor. 0 Rated in accordance with D.O.E. test procedure. 0 Filters must be installed in return air system. Square footages listed are based on 300 f.p.m. face velocity. If permanent filters are used size per manufacturer's recommendations with clean resistance of 0.05" W.C. REVIEWED FOR CODE COMPLIANCE APPROVED JUL 25 2018 City of Tukwila BUILDING DIVISION CITYRECEIVED OF TUKWILA JUL 18 2018 FR IT CENTER 93 25.40 (I] 1 Dimensional Data and Weights 18.03 123/32] 18.29 123/32] 14.22 (9/16] SECTION )(-)( TYPICAL (8) SIDES OF DOWNFLOW DUCT OPENINGS \\_{ ENTER OF GRAVITY a A 513.96 (22-19/321 NOTE: The view labeled "Bottom Side" represents the Base as viewed looking up from underneath the unit. ONDENSATE DRAIN FOR 19.0 (3/41 FEMALE NPT LEFT SIDE 4 INLET TOP SIDE OUTL4 ET FRONT SIDE BOTTOM SIDE Figure 1. WCZ6048A through WCZ6060A (1 of 3) 2 Dimensional Data and Weights RECOMMENDED SERVICE CLEARANCE MM/IN. BOTTOM 0 WITH ECONOMIZER BACK SIDE 304.8 [12] 762.0 (301 LEFT SIDE 914.4 [361 1066.8 [42] RIGHT SIDE 609.6 [24] - FRONT SIDE 762.0 [301 - CLEARANCE TO COMBUSTIBLE MATERIAL MM/IN. BOTTOM 0 BACK SIDE 25.4 [I] LEFT SIDE 152.4 [6] RIGHT SIDE 152.4 [6] FRONT SIDE 304.8 [121 TOP 914.4 [361 457.20 [18] (INSIDE) 82.16 [3.1/4) 24V ENTRY t 359.79 $ 114-5/32] 288.42 225.68 [II Ii/32] [8-7/8] 1 117.73 1 [4-5/8) 107.44 1 [4-7/32] 82.16 13-1/4] 381.00 [15) (INSIDE) BOTTOM DUCT OPENINGS 1 ; try POWER ENTRY 28.58 [I.1/81 DIA. KNOCKOUT 34.93 [I-3/8] DIA. KNOCKOUT 50.01 (1-31/32] DIA. KNOCKOUT �- 150.30 15-29/32] 244.09 19-5/8] POWER ENTRY 28.58 [I-1/81 DIA. KNOCKOUT 34.93 [I-3/8] DIA. KNOCKOUT 50.01 [I-31/32) DIA. KNOCKOUT SINGLE POINT ENTRY 34.93 [1-3/8] DIA. KNOCKOUT 50.01 [1-31/32] DIA. KNOCKOUT 62.71 12-15/32) DIA. KNOCKOUT Figure 2. WCZ6048A through WCZ6060A (2 of 3) 3 381.00 [151 (INSIDE) 325.49 [12-13/16] 457.20 [18] (INSIDE) Dimensional Data and Weights 312.82 [14-11/16) (OUTSIDE) 86.25 [3-13/321 RETURN 449.02 [17.11/16] (OUTSIDE) 449.02 [17-11/161 (OUTSIDE) 116.01 329.58 [12-31/321 16-15/161 BACK DUCT OPENINGS sw f. • 1 58.19 [2-9/32] 530.60 [20.7/81 1351.95 [53-1/32] (SURFACE AREA) BACK SIDE [7./8 [11/161 SECTION X'X TYPICAL 18) SIDES OF SIDEFLOW DUCT OPENINGS MODEL HEIGHT MM/IN. APPROX. CORNER WEIGHT - KG/LBS SHIPPING WEIGHT KG/LEIS TOTAL UNIT WEIGHT KG/LBS CENTER OF GRAVITY MM/IN. A WI W2 W3 W4 B C 4TCY4048 949.33 [37-3/8] 76.2 [1681 47.6 1105] 35.8 (19] 51.6 [127] 275.6 1607) 217.3 [4791 426.7 116.81 635.0 [25.0) 4TCY4060 1050.93 [41.3/81 78.9 [1741 46.7 (1031 34.9 [71] 59.1 1130] 277.8 1612) 219.5 [4841 414.0 [16.3] 635.0 [25.01 4WCY4048 949.33 [31-3/81 68.9 [152) 40.8 [90] 30.8 (681 52.2 [115] 275.6 1601) 217.5 [4791 414.0 [16.31 635.0 [25.01 4WCY4060 1050.93 141-3/81 80.3 11771 41.6 [105] 35.8 (19] 60.8 [1341 282.8 16231 224.5 [495) 414.0 [16.31 635.0 [25.01 4WC16048 1050.93 [41-3/8] 68.9 11521 40.8 [90) 30.8 [68] 52.2 11151 215.6 1601) 211.5 [479] 414.0 [16.31 635.0 [25.0] 4WC16060 1050.93 [41.3/81 80.3 [1771 47.6 [105] 35.8 [791 60.8 11341 282.8 0623) 224.5 [4951 414.0 [16.3] 635.0 [25.01 Figure 3. WCZ6048A through WCZ6060A (3 of 3) 4 Performance Data HIGH STAGE: 4WCZ6048A AT 1600 NOM CFM (COOLING PERFORMANCE AT INDOOR DRY BULB TEMPERATURES) OD ID TOT SENS CAP AT ENTERING DB TEMP TOTAL AMB WB CAP 72 75 78 80 KW 59 45.2 38.6 43.6 45.2 45.2 3.6 63 41.1 31.2 36.2 41.1 44.4 3.6 67 50.8 24.4 29.3 34.3 37.6 3.6 71 54.8 17.5 22.5 27.4 30.1 3.6 85 95 59 42.4 37.4 42.3 42.4 42.4 3.9 63 44.2 30.0 34.9 39.9 43.2 3.9 67 47.6 23.2 28.2 33.1 36.3 4.0 71 51.4 16.4 21.3 26.2 29.5 4.0 105 59 39.6 36.1 39.6 39.6 39.6 4.2 63 41.3 28.9 33.8 38.7 41.3 4.2 67 44.5 22.1 27.0 31.9 35.2 4.3 71 48.0 15.2 20.1 25.1 28.4 4.3 115 59 36.8 34.9 36.8 36.8 36.8 4.5 63 38.3 27.7 32.6 37.5 38.3 4.5 67 41.3 20.9 25.8 30.8 34.1 4.6 71 44.6 14.1 19.0 24.0 27.2 4.6 USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW AIR FLOW CAPACITY TOTAL POWER RATE, CFM MULTIPUER MULTIPLIER LOW 1400 0.97 0.98 HIGH 1800 1.03 1.02 ARI RATING FOR COOLING CFM CAPACITY (A) TEST SEER EER 1580 47500 16.00 12.00 ARI Standard Capacity Rating Conditions ARI STANDARD 210/240 RATING CONDITIONS - (A) Cooling 80°F DB, 67°F WB air entering indoor coil, 95°F DB air entering outdoor coil. (B) High Temperature Heating 47°F DB, 43°F WB air entering outdoor coil, 70°F DB air entering indoor coil. (C) Low Temperature Heating 17°F DB, 15°F WB air entering outdoor coil, 70°F DB air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling. LOW STAGE: 4WCZ6048A AT 1200 NOM CFM (COOLING PERFORMANCE AT INDOOR DRY BULB TEMPERATURES) OD ID TOT SENS CAP AT ENTERING DB TEMP TOTAL USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW AMB WB CAP 72 75 78 80 KW AIR FLOW CAPACITY TOTAL POWER 59 34.5 29.5 33.2 34.5 34.5 1.8 RATE, CFM MULTIPLIER MULTIPLIER 75 63 35.9 23.9 27.6 31.3 33.8 1.9 LOW 1050 0.97 0.98 67 38.7 18.8 22.5 26.2 28.7 1.9 HIGH 1350 1.03 1.02 71 41.8 13.7 17.4 21.1 23.6 1.9 59 32.2 28.5 32.2 32.2 32.2 2.1 ARI RATING FOR COOLING 85 63 33.6 22.9 26.7 30.3 32.8 2.2 CFM CAPACITY(A)TEST SEER EER 67 36.2 17.8 21.5 25.3 27.7 2.2 71 39.0 12.7 16.4 20.1 22.6 2.2 1175 35110 16.00 13.54 90 59 31.0 27.9 31.0 31.0 31.0 2.3 63 32.4 22.4 26.2 29.9 32.3 2.3 67 34.9 17.4 21.0 24.8 27.2 2.3 11 37.7 12.3 16.0 19.6 22.1 2.3 95 59 29.9 27.5 29.9 29.9 29.9 2.4 63 31.2 22.0 25.7 29.4 31.2 2.4 67 33.6 16.9 20.6 24.3 26.8 2.5 71 36.3 11.8 15.5 19.2 21.6 2.5 ARI Standard Capacity Rating Conditions ARI STANDARD 210/240 RATING CONDITIONS - (A) Cooling 80°F DB, 67°F WB air entering indoor coil, 95°F DB air entering outdoor coil. (B) High Temperature Heating 47°F DB, 43°F WB air entering outdoor coil, 70°F DB air entering indoor coil. (C) Low Temperature Heating 17°F DB, 15°F WB air entering outdoor coil, 70°F DB air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling. HIGH STAGE: 4WCZ6048A AT 1600 NOM CFM (HEATING PERFORMANCE AT INDOOR DRY BULB TEMPERATURE) OD TOTAL CAPACITY MBH TOTAL POWER IN KILOWATTS USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW AMB 60 70 15 80 60 70 75 80AIR FLOW CAPACITY TOTAL POWER 2 17.4 17.1 16.9 16.8 2.5 2.6 2.7 2.8 RATE, CFM MULTIPLIER MULTIPLIER 7 20.5 20.2 19.9 19.8 2.6 2.7 2.8 2.9 LOW 1400 0.987 0.975 12 23.6 23.2 23.0 22.8 2.6 2.8 2.9 3.0 HIGH 1800 1.011 1.025 17 26.8 26.3 26.0 25.8 2.7 2.9 2.9 3.0 22 27.7 27.2 26.9 26.7 2.7 2.9 3.0 3.1 27 28.6 28.1 27.8 27.6 2.7 2.9 3.0 3.1 ARI RATING FOR HEATING 32 29.6 29.0 28.7 28.5 2.8 2.9 3.0 3.1 CFM CAPACITY 47 COP 47 CAPACITY 17 COP 17 HSPF 37 32.7 32.1 31.8 31.5 2.8 3.0 3.1 3.2 1580 44500 4.00 26200 2.70 9.00 42 39.1 38.3 38.0 37.6 2.9 3.1 3.2 3.3 47 45.5 44.6 44.2 43.8 3.1 3.3 3.4 3.5 52 48.6 47.7 47.2 46.8 3.1 3.3 3.4 3.5 ARI Standard Capacity Rating Conditions 57 51.7 50.7 50.2 49.8 3.2 3.4 3.5 3.6 ARI STANDARD 210/240 RATING CONDITIONS - (A) Cooling 80°F DB, 67°F WB air 62 54.8 53.8 53.2 52.8 3.3 3.5 3.6 3.7 entering indoor coil, 95°F DB air entering outdoor coil. (8) High Temperature Heating 61 57.9 56.8 56.3 55.8 3.3 3.5 3.7 3.8 47°F DB, 43°F WB air entering outdoor coil, 70°F DB air entering indoor coil. (C) Low 72 61.0 59.9 59.3 58.8 3.4 3.6 3.7 3.8 Temperature Heating 17°F DB, 15°F WB arc entering outdoor coil, 70°F DB air entering indoor coil. (0) Rated indoor airflow for heating is the same as for cooling. LOW STAGE: 4WCZ6048A AT 1200 NOM CFM (HEATING PERFORMANCE AT INDOOR DRY BULB TEMPERATURE) OD TOTAL CAPACITY MBH TOTAL POWER IN KILOWATTS USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW AMB 60 70 75 80 60 70 75 80 AIR FLOWCAPACITYTOTAL POWER 22 20.0 19.7 19.5 19.3 2.1 2.2 2.3 2.3 RATE, CFMMULTIPUERMULTIPUER 27 21.7 21.3 21.1 20.9 2.1 2.3 2.3 2.4 LOW 1050 0.987 0.975 HIGH 1350 1.011 1.025 32 23.4 23.0 22.7 22.5 2.2 2.3 2.4 2.4 37 25.7 25.2 25.0 24.7 2.2 2.3 2.4 2.4 ARI RATING FOR HEATING 42 29.0 28.4 28.1 27.9 2.2 2.3 2.4 2.4 CFM CAPACITY 47COP 47CAPACITY 17COP 17 HSPF 47 32.2 31.6 31.3 31.0 2.2 2.3 2.4 2.4 1175 31496 4.02 17947 2.42 9.00 52 34.5 33.9 33.5 33.2 2.2 2.3 2.4 2.5 ARI Standard Capacity Rating Conditions 57 36.8 36.2 35.8 35.5 2.2 2.3 2.4 2.5 ARI STANDARD 210/240 RATING CONDITIONS - (A) Cooling 80°F DB, 67°F WB air 62 39.2 38.4 38.0 37.7 2.2 2.4 2.4 2.5 entering indoor coil, 95°F DB air entering outdoor col. (B) High Temperature Heating 47°F 67 41.5 40.7 40.3 39.9 2.2 2.4 2.5 2.5 DB, 43°F WB air entering outdoor coil, 70°F DB air entering indoor coil. (C) Low Temperature Heating 17°F DB, 15°F WB air entering outdoor coil, 70°F D8 air entering 72 43.8 43.0 42.5 42.1 2.3 2.4 2.5 2.6 indoor coil. (D) Rated indoor airflow for heating is the same as for cooling. 5 Indoor Blower Performance Indoor Fan Performance 4WCZ6048A Horizontal External Static Pressure (in. wg) 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 350 CFM/Ton Setting Low - 954 973 977 973 966 957 950 944 - - High - 1363 1390 1396 1390 1379 1368 1358 1349 - - 400 CFM/Ton Setting Low - 1121 1106 1104 1106 1108 1108 1104 1097 - - High - 1601 1580 1577 1580 1583 1583 1577 1567 - - 450 CFM/Ton Setting Low - 1223 1254 1268 1271 1268 1264 1261 1258 - - High - 1747 1792 1811 1816 1812 1806 1801 1797 - - Down Flow External Static Pressure (in. wg) 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 350 CFM/Ton Setting Low - 948 977 977 970 969 975 979 962 - - High - 1354 1396 1396 1386 1384 1393 1399 1375 - - 400 CFM/Ton Setting Low - 1102 1106 1109 1113 1116 1119 1120 1118 - - High - 1574 1580 1585 1589 1594 1599 1601 1597 - - 450 CFM/Ton Setting Low - 1295 1277 1272 1273 1274 1273 1272 1273 - - High - 1851 1824 1817 1818 1820 1819 1817 1819 - - 4WCZ6048 AIRFLOW WITH AUXILIARY HEAT (CFM) SWITCH SETTINGS SELECTION NOMINAL AIRFLOW 7 -OFF 8 -OFF LOW 1400 CFM 7 -ON 8 -OFF HIGH 1600 CFM 7 -OFF 8 -ON HIGH 1600 CFM 7 -ON 8 -ON HIGH 1600 CFM COOLING FAN DELAY OPTIONS SWITCH SETTINGS DELAY NOMINAL AIRFLOW 5 -OFF 6 -OFF NONE 100% 5 -ON 6 -OFF 45 SEC 100% 5 -OFF 6 -ON 90 SEC 50% 5 -ON 6 -ON ** 50-100% ** This ENHANCED MODE selection provides a ramping up and ramping down of the indoor blower speed to provide improved comfort, quietness, and potential energy savings. The Graph below shows the ramping process 6 SYSTEM AIRFLOW (CFM) 50% OFF 35% 80% SECOND STAGE 56% FIRST STAGE Dehumidify Fast Coll Cooling Enhanced Comfort 1 1 minute 7.5 minutes 100% Only if required Only if required 50% I 3 minutes (Fan Only) COMPRESSOR OPERATION ON OFF OFF Supplementary Electric Heaters BAYHTRV105, 108, 110, 115, 120, 125, 305, 308, 310, 315, 320. 325, 405, 408, 410, 415, 420, 425D UNIT MODEL ELECTRIC HEATER MODEL RATED VOLTAGE PHASE AMPS HEATER CAPACITY NO. OF STAGES KW/STAGE MCA MAX FUSE OR HACR CKT BKR SIZE (4) CANADA ONLY MAX. CKT BKR SIZE (5) KW BTUH 1 2 4WCZ6036-060A1 BAYHTRV105D 208/240 208/240 1 18/21 3.76/5.0 12800/17100 1 3.76/5.0 45 23/26 25/30 25/30 4WCZ6036-060A1 BAYHTRV108D 1 29/33 6.0/8.0 20500/27300 1 6.0/8.0 55 36/41 40/45 40/45 4WCZ6036-060A1 BAYHTRV110D 208/240 1 36/42 7.5/10.0 25600/34100 1 7.5/10.0 4WCZ6036A4 45/52 45/60 45/60 4WCZ6036-060A1 BAYHTRV115D 208/240 1 54/63 11.27/15.0 38500/51200 2 7.5/10.0 3.76/5.0 68/78 70/80 70/80 4WCZ6048-060A1 BAYHTRV120D 208/240 1 72/83 15.0/20.0 51200/68300 2 7.5/10.0 7.5/10.0 "90/104 90/110 90/110 4WCZ6048-060A0 BAYHTRV125D 208/240 1 90/104 18.78/25.0 64100/85300 2 11.26/15.0 7.5/10.0 113/130 125/150 125/150 4WCZ6036.060A3 BAYHTRV305D 208/240 3 10/12 3.76/5.0 12800/17100 1 3.76/5.0 79 13/15 15/15 15/15 4WCZ6036-060A3 BAYHTRV308D 208/240 3 17/19 6.0/8.0 20500/27300 1 6.0/8.0 BAYHTRV115D 21/24 25/25 25/25 4WCZ6036-060A1 BAYHTRV310D 208/240 3 21/24 7.5/10.0 25600/34100 1 7.5/10.0 150 26/30 30/30 30/30 4WCZ6036-060A1 BAYHTRV315D 208/240 3 31/36 11.27/15.0 38500/51200 2 7.5/10.0 3.76/5.0 39/45 40/45 40/45 4WCZ6048-060A1 BAYHTRV320D 208/240 3 42/48 15.0/20.0 51200/68300 2 7.5/10.0 7.5/10.0 52/60 60/60 60/60 4WCZ6048-060A3 BAYHTRV325D 208/240 3 52/60 18.78/25.0 64100/85300 2 11.26/15.0 7.5/10.0 65/75 70/80 70/80 4WCZ6036-060A4 BAYHTRV405D 480 3 6 5.0 17100 1 5.0 8 15 15 4WCZ6036-060A4 BAYHTRV408D 480 3 10 8.0 27300 1 8.0 13 15 15 4WCZ6036-060A2 BAYHTRV410D 480 3 12 10.0 34100 1 10.0 15 15 15 4WCZ6036-060A3 BAYHTRV415D 480 3 18 15.0 51200 2 10.0 5.0 23 25 25 4WCZ6048-060A3 BAYHTRV420D 480 3 24 20.0 68300 2 10.0 10.0 30 30 30 4WCZ6048-060A3 BAYHTRV425D 480 3 30 25.0 85300 2 15.0 10.0 38 40 40 Single Power Entry Kit BAYSPEK60, 61, 62, 63, 64, 65D SINGLE POINT POWER ENTRY KIT HEATER MODEL UNIT MODEL MIN. CKT. AMP. MAX OVER -CURRENT PROTECT. DEVICE BAYSPEK060D BAYHTRV105D 4WCZ6036A1 52 60 BAYSPEK061D BAYHTRV3050 4WCZ6036A3 34 40 4WCZ6048A3 40 50 4WCZ6060A3 45 60 BAYHTRV308D 4WCZ6036A3 43 45 4WCZ6048A3 49 50 4WCZ6060A3 54 60 BAYHTRV310D 4WCZ6036A3 49 50 4WCZ6048A3 55 60 BAYHTRV405D 4WCZ6036A4 18 20 4WCZ6048A4 23 25 4WCZ6060A4 27 30 BAYHTRV4080 4WCZ6036A4 22 25 4WCZ6048A4 27 30 4WCZ6060A4 31 35 BAYHTRV410D 4WCZ6036A4 25 25 4WCZ6048A4 30 30 4WCZ6060A4 34 40 BAYHTRV415D 4WCZ6036A4 33 35 4WCZ6048A4 38 40 4WCZ6060A4 42 45 BAYHTRV420D 4WCZ6048A4 45 45 4WCZ6060A4 49 50 BAYSPEK062D BAYHTRV105D 4WCZ6048A1 60 70 4WCZ6060A1 63 80 BAYHTRV108D 4WCZ6036A1 68 70 4WCZ6048A1 76 80 4WCZ6060A1 79 90 BAYHTRV110D 4WCZ6036A1 78 80 4WCZ6048A1 86 90 4WCZ6060A1 89 100 BAYSPEK063D BAYHTRV115D 4WCZ6036A1 104 110 4WCZ6048A1 112 125 4WCZ6060A1 115 125 BAYHTRV120D 4WCZ6048A1 138 150 4WCZ6060A1 141 150 BAYSPEK064D BAYHTRV315D 4WCZ6036A3 64 70 4WCZ6048A3 70 70 4WCZ6060A3 75 80 BAYHTRV320D 4WCZ6048A3 85 90 BAYSPEK065D BAYHTRV310D 4WCZ6060A3 60 70 INSTALLER OF THE SINGLE POINT POWER ENTRY KIT MUST CHECK THE APPROPRIATE BOX ABOVE TO RECORD THE KIT. HEATER. AND UNIT MODEL NUMBERS INSTALLED. POWER SUPPLY VOLTAGE TO UNIT AND HEATER MUST BE IDENTICAL. CHECK THE UNITAND HEATER NAMEPLATES TO DETERMINE THE CORRECT POWER SUPPLY VOLTAGE. CHECK HEATER NAMEPLATE TO DETERMINE HEATER KW AND CURRENT RATING. MINIMUM INSTALLATION CLEARANCE TO COMBUSTIBLE MATERIAL WHEN ELECTRIC HEATERS ARE INSTALLED. UNIT CABINET - 0", PLENUM - 0" AND OUTLET DUCT - 0" EXCEPT FOR BAYHTRV415D AND BAYHTRV425D WHEN INSTALLED IN 4WCZ6060A4 UNIT ONLY. MINIMUM INSTALLATION CLEARANCE TO COMBUSTIBLE MATERIAL WHEN BAYHTRV415D AND BAYHTRV425D HEATERS ARE INSTALLED IN 4WCZ6060A4 UNIT ONLY: UNIT CABINET - 1", PLENUM - 1" AND OUTLET DUCT - 1"PLACE ABOVE LABEL OVER "ELECTRIC HEATER INSTALLED" NAMEPLATE ON UNIT 7 Optional Equipment BAYCURB051A Full Perimeter Roof Mounting Curb for 4WCZ6048-060A CHANNEL END The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct, build or modify the items depicted in the drawings. The manufacturer is not responsible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use. CHANNEL SIDE WOOD NAILER 8 ** 42.00 WITH ECONOMIZER WITH 25% FRESH AIR ACCESSORY SERVICE CLEARANCE DIMENSIONS A B C D WC*/TC* 42.00 36.00 12.00** 24.00 DC*/YC* 42.00 36.00 12.00** 36.00 ** 42.00 WITH ECONOMIZER WITH 25% FRESH AIR ACCESSORY Optional Equipment A 3 "C" MAX. CURB WIDTH F I I UNIT DOWNFLOW RETURN OPENING I • 1 rr(REC�OMY ENDED PERIMETER S) II 1 2-7/8" UNIT DOWNFLOW r SUPPLY OPENING L I B x r RECONMIENDED FIELD CURB MITER (TO TOP CURB FLANOEF4 PLACES � J CURB BASE PAN "D" MAX. CURB LENGTH TOP VIEW OF UNIT BASE PAN WITH FIELD CURB BELOW REFERENCE ILLUSTRATION FOR A CUSTOMER SUPPLED ROOF CURB 2-7/8" F5/9 X 1.5/9 UNT MITER (4 CORNERSI MATFROM 01174S2 MODEL A 5 C D E F G H J K L 2/4 1.C.,YC*,WCe018,024,030,036 48-3/8 40-7/8 38-7/8 46-3/8 16 12 Z 6-5/8 6-7/8 12 16 2/4 7.C.,YC4,WCr042,048,060 58 43-7/8 41-7/8 56 18 15 18 9-5/8 12-I/2 x 15 BAYFLTR101, 201A, 1" - 2" Filter Rack (Mounts in Filter/Coil Section) Filter The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct, build or modify the items depicted in the drawings. The manufacturer is not responsible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use. 9 A Optional Equipment BAYECON103,104A Down Discharge Economizer and Rain Hood (Mounts Over Horizontal Return Air Opening) Economizer rain hood HVAC Unit Mist eliminator Relief damper Roofcurb The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct, build or modify the items depicted in the drawings. The manufac- turer is not responsible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use. Go G. 000 ee9 e6 8 Go c eec Go G. G. ® e•6 c ®6a a e®a ® e.6 Go® G. p 63® GP G. o .06 C 6G 63 e• 063 O 00006 T Outside dampers Return air dampers Required filter kit, order separately L Return Duct Economizer Models A BAYECON103A 4WCZ6036A 4DCZ6036A 4YCZ6036A 201/8" BAYECON104A 4WCZ6048-060A 4DCZ6048-060A 4YCZ6048-060A 24 3/8" BAYCON203,204A Horizontal Economizer and Rain Hood Economizer Gaskets (2) Rain Hood Economizer A B C D E BAYECON203AA 22" 20" 16 7/8" 15 11/16 11 11/16 BAYECON204AA 24" 22 21/32" 19" 17 11/16 14 11/16 10 Optional Equipment BAYOSAH001,002A, 25% Outside Air Damper (Replaces Filter/Coil Access Panel) The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct, build or modify the items depicted in the drawings. The manufacturer is not responsible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unautho- rized use. Manual Fresh Air Model Unit Application Models A B C D BAYOSAH001 2/4YC*,WC**018 036A 4TC*,DC**018-036A 22 7/16" 20 11/16" 12 3/8" 9 3/16" BAYOSAH002 2/4YC*,WC**042 060A 4TC*,DC**042-060A 25 3/16" 20 11/16" 12 3/8" 9 3/16" 11 FULLY OPEN FULLY CLOSED Mechanical Specifications General The units shall be horizontal airflow as shipped and convertible to downflow. All units shall be factory assembled, piped, in- ternally wired and fully charged with refrigerant. Units shall be UL listed and car- ry a UL label. All units shall be factory run tested to check cooling operation, fan and blower rotation and control or TXV se- quence. Units shall be designed to operate at ambient temperatures between 115°F and 55°F in cooling as manufactured. Cool- ing performance shall be rated in accordance with ARI standards. Unit Casing All components shall be mounted in a weather -resistant steel cabinet with an enamel finish. Access panels shall be pro- vided for unit controls and indoor coil and fans. Indoor air section compartment shall be completely insulated with fireproof, per- manent, odorless glass fiber material. Knockouts shall be provided for utility and control connections. Drain connections shall be provided to accommodate indoor water runoff. Compressor The compressor shall be hermetically sealed, high efficiency Climatuff® two-stage compressors. Internal overcurrent and over temperature protection, internal pressure relief shall be standard. Refrigeration System All units shall have TXV in cooling and TXV in heating. Service pressure tap ports, and a refrigerant line filter dryer shall be stan- dard. Indoor Coil Coils shall be internally finned or smooth bore 3/8" copper tubes mechanically bond- ed to configured aluminum plate fin as standard. Evaporator coil leak and pres- sure tested to 200 psig; condenser coil tested to 450 psig. Trane 6200 Troup Highway Tyler, TX 75707-9010 Condenser Coit — The Spine FinTM condenser coil shall be continuously wrapped, corrosion resistant all aluminum with minimum brazed joints. This coil is 3/8 inch O.D. seamless aluminum tubing glued to a continuous aluminum fin. Coils are lab tested to withstand 2,000 pounds of pressure per square inch. The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by louvered panels. Indoor Air Fan — Direct -drive, forward - curved, centrifugal wheel in a Composite Vortica® Blower housing. Motor shall have thermal overload protection. Permanently lubricated motor bearings. Motor/blower assembly isolated from unit with rubber mounts. Condenser Fan — Direct -drive, draw thru propeller type. Weather -proofed permanent split capacitor fan motor shall have built-in thermal overload and permanently lubricated motor bearings. System Controls System controls include condenser fan, evaporator fan and compressor contac- tors. Accessories Roof Curb — The roof curb shall be de- signed to mate with the unit and provide support and complete weathertight instal- lation when properly installed. Adhesive back polyurethane sealing strips shall be provided to ensure an airtight seal be- tween supply and return openings of the curb and unit. The roof curb design allows field fabricated ductwork to be connected directly to the curb. Curb ships knocked down for field assembly, and includes fac- tory -installed wood nailer strips. Electric Heaters — Each heater assem- bly shall include power supply fusing if over 48 amps, automatic resetting limit switches and heat limiters for thermal pro- tection. Heaters shall be provided with polarized plugs for quick connection to unit low voltage wiring. Electric heat modules shall be UL listed. c Single Source Power Entry — This acces- sory when used with electric heat accessory shall allow single source power connection to unit and heater combination. Single source power entry kits shall have specific matching heater(s). Kit shall include high voltage terminal blocks, fuse blocks and fuses, cut -to -length interconnecting wir- ing, and junction box (if required) to provide power sources with fuse protection as re- quired for both the unit and accessory heater. Kit components shall install within the unit cabinet in the heater access sec- tion. Single source branch power circuit shall be protected and wired in accordance with local codes. Fully Modulating Economizer — This ac- cessory shall be field installed and be composed of the following items: 0-100% fresh air damper, damper drive motor, fixed dry bulb enthalpy control, and low voltage wiring plug for electrical connections. Solid state enthalpy or differential enthalpy con- trol is optional. Economizer operations shall be controlled by the preset position of the enthalpy control. A barometic relief damper shall be standard with the economizer and provide a pressure operated damper that shall be gravity closing and prohibit en- trance of outside air on equipment "off' cycle. Economizer requires BAYRLAY004A relay kit to interface the economizer to the heat pump. Manual Outside Air Dampers — Rain hood and screen shall be field installed. Suitable for up to 25% outside air. Start Kit — Extra compressor starting ca- pacity for single phase equipment. Control Options Standard Indoor Thermostats — Two stage heating/cooling or one stage heating/ cooling thermostats shall be available in ei- ther manual or automatic changeover. Programmable Electronic Night Setback Thermostat — Programmable electronic thermostat shall provide heating setback and cooling setup with 7 -day, programming capability. 1H/1C or 2H/2C models avail- able. US ENERGY STAR The manufacturer has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice. 12 5/2/2019 City of Tukwila Department of Community Development DAVE ANDRINGA 1402 MAPLE AVE SW RENTON, WA 98057 RE: Permit No. M18-0093 RELIABLE PARTS 1051 ANDOVER PARK W Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 6/15/2019. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 6/15/2019, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, 4., &(A//' Wf) andace Nichols Permit Technician File No: M18-0093 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 12/2/2018 l � City of Tukwila Department of Community Development DAVE ANDRINGA 1402 MAPLE AVE SW RENTON, WA 98057 RE: Permit No. M18-0093 RELIABLE PARTS 1051 ANDOVER PARK W Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 1/28/2019. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 1/28/2019, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, ti4gyRachelley Permit Technician File No: M18-0093 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 OERM1T COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M18-0093 PROJECT NAME: RELIABLE PARTS SITE ADDRESS: 1051 ANDOVER PARK W X Original Plan Submittal Response to Correction Letter # DATE: 07/18/18 Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: Building Division Public Works OM 14R - Fire Prevention Structural Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 07/19/18 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 08/16/18 Approved Corrections Required n Approved with Conditions n nDenied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg D Fire ❑ Ping 0 PW D Staff Initials: 12/18/2013 SEA AIRE INC Washington State Department of Labor & Industries I -/arae Espanol Contact: Safety & Health Claims & Insurance F Search L&I Page 1 of 2 11 '` I A -Z Index Help My UM Workplace Rights Trades & Licensing SEA AIRE INC Owner or tradesperson Principals MCCURRY, JOHN M, PRESIDENT MCCURRY, JUDY A, VICE PRESIDENT MCCURRY-WARD, JENNIFER L, SECRETARY MCCURRY, DEBRA J, TREASURER MCINTYRE, FRANCIS D (End: 01/01/1980) MCINTYRE, CHRISTINE L (End: 01/01/1980) Doing business as SEA AIRE INC WA UBI No. 600 360 471 1402 Maple Ave SW RENTON, WA 98057 206-575-8051 KING County Business type Corporation License Verify the contractors active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. ..._....................................... Meets current requirements. License specialties GENERAL License no. SEAAII'206JQ Effective — expiration 04/18/1980— 05/04/2020 Bond AMERICAN STATES INS CO Bond account no. 6162430 $12,000.00 Received by L&I Effective date 04/18/2002 04/18/2002 Expiration date Until Canceled Insurance ...... _..... Western National Assur Co $1,000,000.00 Policy no. CPP1184108 Received by L&I Effective date 04/05/2018 04/18/2018 Expiration date 04/18/2019 Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=600360471&LIC=SEAAII*206JQ&SAW= 8/1/2018 SEA AIRE INC Insurance history Savings ............. No savings accounts during the previous 6 year period. Lawsuits against the bond or savings _.. a s against bond or...a n9 previousyearperiod. lawsuits a ainst the or savings accounts duringthe 6 L&I Tax debts ........................... No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. This company has multiple workers' comp accounts. Active accounts L&I Account ID 989,118-00 Doing business as SEA-AIRE INC Estimated workers reported Pending current quarter filing L&I account contact T4 / TERRI MADISON (360)902-4654 - Email: KIRT235@Ini.wa.gov Track this contractor 0 Account is current. Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes . ..... ...... .... No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health No inspections during the previous 6 year period. Page 2 of 2 Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Wash'ngton. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=600360471&LIC=SEAAII*206JQ&SAW= 8/1/2018