Loading...
HomeMy WebLinkAboutPermit M18-0095 - STERLING SOUTHCENTER - NEW FIREPLACESTERLING SOUTHCENTER 407 BAKER BLVD EXPIRED 02/02/19 M18-0095 Parcel No: Address: City of Tukwila 1 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov 0223100087 407 BAKER BLVD Project Name: STERLING SOUTHCENTER MECHANICAL PERMIT Permit Number: M18-0095 Issue Date: 8/6/2018 Permit Expires On: 2/2/2019 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: PEARL ALVIN+CARLE 9741 E ESTANCIA WAY, SCOTTSDALE, WA, 85262 WILLIAM MILLHOLLIN 9808 31ST AVE SE , EVERETT, WA, 98208 FIRESIDE HOME SOLUTIONS 18389 SW BOONES FERRY RD , PORTLAND, OR, 97224 FIRESHS879RU //1 Phone: (206) 601-7043 Phone: (503) 684-8535 Expiration Date: 1/14/2020 DESCRIPTION OF WORK: INSTALL AESTHETIC ONLY NEW FIREPLACE IN THE LOBBY AREA ON THE 1ST FLOOR, INCLUDING VENTING AND DUCTWORK. NO HEATING CAPACITY Valuation of Work: $35,766.00 Type of Work: NEW Fuel type: GAS Fees Collected: $677.21 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Permit Center Authorized Signature:(A. Date: V —(g l I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature:./ Datee1067 Print Name: ‘)1((149(", ? /�, I ' �l /(^ This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 4: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 5: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 6: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 7: ***MECHANICAL PERMIT CONDITIONS*** 8: All mechanical work shall be inspected and approved under a separate permit Permit Center (206/431-3670). 9: Manufacturers installation instructions shall be available on the job site at the PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 0708 GAS FIREPLACE INSERT 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0701 ROUGH -IN MECHANICAL issued by the City of Tukwila time of inspection. ! \ CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. 1\41(6— Project " 4I(6— Project No. Date Application Accepted: 11 Date Application Expires: \ I \t2 (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION King Co Assessor's Tax No.: 0223100080 Site Address: 415 Baker Blvd Suite Number: Floor: 1 Tenant Name: STERLING SOUTHCENTER PROPERTY OWNER Name: BAKER BOULEVARD ASSOCIATES Address: 415 BAKER ST City: TUKWILA State: WA Zip: 98188 CONTACT PERSON — person receiving all project communication Name: WILLIAM MILLHOLLIN Address: 9808 31st Ave SE City: Everett State: WA Zip: 98208 Phone: (206) 601-7043 Fax: Email: william@nwpermit.com New Tenant: ❑ Yes ..No MECHANICAL CONTRACTOR INFORMATION Company Name: Fireside Home Solutions Address: 21402 84th Ave S City: KENT State: WA Zip: 98032 Phone: (360) 945-2787 Fax: Contr Reg No.: FIRESHS879RU Exp Date: 01/14/2020 Tukwila Business License No. Valuation of project (contractor's bid price): $ Describe the scope of work in detail: Install aesthetic only new fireplace in the Lobby area on the 1st floor, including venting and ductwork. (No new heating capacity) 35,766 Use: Residential: New ❑ Replacement ❑ Commercial: New ((] Replacement ❑ Fuel. Type: Electric ❑ Gas Other: HAApplications On Line\2016 Applications\Mechanical Permit Application Revised 1-4-16.docx Revised: January 2016 bh Page 1 of 2 O Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Residential, Nighttime Furnace >100k btu Industrial Floor furnace 55 dB(A) Suspended/wall/floor mounted heater 1 Appliance vent Commercial Repair or addition to heat/refrig/cooling system 47 dB(A) Air handling unit 65 dB(A) <10,000 cfm 60 dB(A) Unit Type Qty Air handling unit Residential, Nighttime >10.000 cfm Industrial Evaporator cooler 55 dB(A) Ventilation fan connected to single duct 1 Ventilation system Commercial Hood and duct 47 dB(A) Incinerator — domestic 65 dB(A) Incinerator — comm/industrial 60 dB(A) / 1 Unit Type Qty Fire damper Residential, Nighttime Diffuser Industrial Thermostat 55 dB(A) Wood/gas stove 1 Emergency generator Commercial Other mechanical equipment 47 dB(A) 60 dB(A) 65 dB(A) Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-10PM, Monday through Friday and 8AM-10PM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code. including: Warning devices; • Construction and property maintenance during the daytime hours (7am-lOpm); • Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extersion shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER O,R AUTHORIZED AGENT: Signature: f ,1 Date: 0/20/(0e Print Name: William Millhollin Day Telephone: (206) 601-7043 Mailing Address: 9808 31st Ave SE H:\Applications\Forms-Applications On Line\2016 Applications\.Mechanical Permit Application Revised 1-4-16.docx Revised: January 2016 bh Everett City WA 98208 State Zip Page 2 of 2 % \ ash Register Rece° City of Tukwila DESCRIPTIONS � PermitTRAK ACCOUNT QUANTITY ;. PAID $546.98 M18-0095 Address: 407 BAKER BLVD Apn: 0223100087 $546.98 MECHANICAL $520.93 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $487.78 TECHNOLOGY FEE $26.05 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R15103 R000.322.900.04.00 0.00 $26.05 '` $546.98 Date Paid: Monday, August 06, 2018 Paid By: NORTHWEST PERMIT INC Pay Method: CHECK 11131 Printed: Monday, August 06, 2018 3:58 PM 1 of 1 SYSTEMS eceipt Number fa R14999 DESCRIPTIONS l PermitTRAK $130.23 M18-0095 Address: 415 BAKER BLVD BLDG Apn: 0223100080 $130.23 MECHANICAL $130.23 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: 814999 R000.322.102.00.00 0.00 $130.23 $130.23 Date Paid: Friday, July 20, 2018 Paid By: NORTHWEST PERMIT Pay Method: CHECK 11099 Printed: Friday, July 20, 2018 2:41 PM 1 of 1 2, . .. �1 L (SYSTEMS THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF CANADIAN HEATING PRODUCTS. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF CANADIAN HEATING PRODUCTS IS PROHIBITED. c 33 O D m Ci< O m r- r r- m OC C C Z - i m_ cn D S m � m 0 0 C m m m 0 S -1 p O m D (/) Z p z m 0) m m D 0 z 1 I+ 0) LIOZ/60/92 AI 03131O3dS 3SIM!13HIO SS31Nf1 UiOD' 06,1UOW'MMM 5:3 -')-J c 20 N dol a>imui anissed 4. 71 1/2" GLASS r r A A ��.L.1\190 iliAlbrad' 11 1 1 1 1 S f0 0) V 0) N X T t 1/2/2019 City of Tukwila Department of Community Development WILLIAM MILLHOLLIN 9808 31ST AVE SE EVERETT, WA 98208 RE: Permit No. M18-0095 STERLING SOUTHCENTER 415 BAKER BLVD Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 2/2/2019. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 2/2/2019, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: M18-0095 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 =PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M18-0095 DATE: 07/24/18 PROJECT NAME: STERLING SOUTHCENTER SITE ADDRESS: 415 BAKER BLVD X Original Plan Submittal Revision # Response to Correction Letter # before Permit Issued Revision # after Permit Issued DEPARTMENTS: Building Division Public Works Fire Prevention Structural Planning Division ❑ Permit Coordinator El PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 07/26/18 Structural Review Required REVIEWER'S INITIALS: DATE: El APPROVALS OR CORRECTIONS: Approved Corrections Required ❑ Approved with Conditions ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) DUE DATE: 08/23/18 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW ❑ Staff Initials: 12/18/2013 FIRESIDE HOME SOLUTIONS Hone Espanol Contact Safety & Health Claims & Insurance cjiWashington State Department of Labor & Industries [Search L&I Page 1 of 2 x �= A -Z Index Help My L&I Workplace Rights Trades & Licensing FIRESIDE HOME SOLUTIONS Owner or tradesperson Principals WATERSTRAAT, JOHN MITSUOKA, PARTNER/MEMBER WIDDOWS, THOMAS ABE, MANAGER (End: 01/11/2018) Doing business as FIRESIDE HOME SOLUTIONS WA UBI No. 603 198 045 Parent company FIRESIDE CONTRACTING SRVCS LLC 18389 SW BOONES FERRY RD PORTLAND, OR 97224 503-684-8535 Business type Limited Liability Company Governing persons PACIFIC COAST JOHN MITSUOKA WATERSTRAAT; THOMAS A WIDDOWS; INC FIRESIDE OF OREGON; INC FIRESIDE OF WASHINGT; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. FIRESHS879RU Effective — expiration 01114/2014— 01/14/2020 Bond RLI Ins Co Bond account no. LSM0782709 Active. Meets current requirements. $12,000.00 Received by L&I Effective date 01/22/2016 01/22/2016 Expiration date Until Canceled Bond history Insurance American Fire & Casualty Co $1,000,000.00 Policy no. BKA56692518 Received by L&I Effective date 05/29/2018 06/01/2018 Expiration date Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=603198045&LIC=FIRESHS879RU&SAW= 8/6/2018 FIRESIDE HOME SOLUTIONS Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings 06101112019 No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID 279,898-00 Account is current. Doing business as FIRESIDE HOME SOLUTIONS Estimated workers reported Quarter 2 of Year 2018 "Greater than 100 Workers" L&I account contact T4 1 STEPHEN TASSONI (360)902-4819 - Email: TASS235@Ini.wa.gov Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health No inspections during the previous 6 year period. Page 2 of 2 © Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=603198045&LIC=FIRESHS879RU&SAW= 8/6/2018 aa aaaa a;- 16"x16" OFFICES SERVED BY A DEDICATED OUTDOOR AIR YSTEM (DOAS): HEAT RECOVERY VENTILATOR HRV-1. r vVI 7 .7..'.9.0. LOUVER AT 12" 1 'v,vvv-vv V7777'7'77 10"0 B -VENT LEVEL 2 14"x8" OUTDOOR AIR DOWN TO LOW LEVEL. 39'-0" M OCEAN PARK MECHANICAL 6283,14900 INTER URBAN AVE TELEPHONE 206-6744553 SEATTLE, WA 98168 FACSIMILE 206-6744564 MANAGER' 7 JFFICE ASSISTN^ER ENTRY VESTIBULE 14"x8" COMBUSTION AIR E ROOM VAN 182 SF 8"0 COMBUSTION AIR 14"x8" EXHAUST ABS 14"x8" OUTDOOR AIR N\ SECONDARY PARKING P100B •ann cG 1 ' 8 x8 LEVEL 1 28'-0" FIREPLACE SECTION SCALE: 1/8" =1'-0" LOBBY VEJV3ING'OF FIREPLACE BY OTHERS UNDER �SEPARATE MECHANICAL PERMIT. 102 2590 SF PROJECT STERLING SOUTHCENTER 415 BAKER BOULEVARD TUKWILA, WA 98188 SECONDARY PARKING 100B: 3,181 S.F. 0.75 CFM PER SF = 2,400 CFM PROVIDE (1) 2,500 CFM GARAGE TRANSFER FAN. 30" HIGH •;/ Jt0'. KUUh 104 SF I I - I II j I II 39"x12 WIRED TO FC -3. PARCEL 115 SF ELEV 1:40! 18"X10" LJBISTROI V)I�:686 SF"" 1 ArArAwir121 x12 171 —41r4 f. Pik �►4�t' 26"x12" EXHAUST,; ' D ,MAKE-UP AIR DUCTS FOR FUTURE .. ft CHEtL HORIZONTAL DUCTING ON LEVEL 1Xo_THERS. �"-x24P,A 96 KITCHEN EXHAUST DUCT F9\YNTTj/F9RE RATED DUCT WRAP AND `A4CCESS)PAN,EL ON EACH FLOOR. '20" 24 , ATE -UP AIR DUCT FA. 44 x14 v,FA R7 IHERM J INSULATION ON OUTDOOR AIR DUCT 10£41❑ END SWITCH ON CO/N021-1 WIRED TO GTF-1-2. \ END SWITCH oN CO/N021 2 / \ WIRED TO GTF-1-3 & 4. FUTURE KITCHEN HOODS OTHERS INCLUDING E' DING DUCTS TO VERTICAL RISERSBEHIND ELEVATOR 1.1 VFDs FOR GARAGE E)yfIAUST \ \ FANS GEF -2-i1 TO GEF -2-3 \-MOUNTED-VEIITfCALIrONINALL.- 24"x24" 1514 SF THERM0STA WITH CO2 FOR DEMAND CONTROL VEN1iIA110N: OTDOOR AIR DAMPER SHALL BE -OPENED IN IRESPOINSE TO -0O2 tEVEb— - 2Q1EYS 0403.2.6.SPACE IS > 500 SF AND �CCJPLIiVTbAD IS > 25 PEOPLE PER 1,000 S.F. 0000170°G7 nn.,00 H sa f7C CATERING TCHEN 12U 95 Si RESIDE` T IAL PARKING GARAG;:: P100A 22407 SF ■ ;000000 i?;.,'I .000000 100000❑ I 00000 111 ?000 �r�❑ '0 Cfrf CITO 000000 000000 '00000 000000 '0000000 18"x18" — _ _ 4 _ELECTRICAL CONTRACTOR SHALL SUPPLY DIESEL FUEL FIRED EMERGENCY GENERATOR, SUBBASE FUEL TANK, MUFFLER, AND REMOTE FUEL FILL STATION. IN ACCORDANCE WITH GENERATOR'S INSTRUCTIONS MECHANICAL CONTRACTOR SHALL CINSTAI DUCTING FROM RADIATOR TO EXHAUST LOUVER, DUCTING FROM AIR INTAKE LOUVER TO ROOM FOR COMBUSTION AIR, ENGINE EXHAUST PIPE FROM MUFFLER TO DISCHARGE POINT, SUBBASE FUEL TANK VENTS TO EXTERIOR WALL (MINIMUM 5'-O" FROM BUILDING OPENINGS), AND PIPING -I- FROM DUEL -FILL -STATION -TO SUBBASE - - 1.^1101111.2 \.‘rIlIP11010110111FINII 18"x10" ?8'x15 1:10.00rloa0 1nr,r o LO I ERS fA BE 3'-O" 1 FRovio_EERABLE OPENINGMINIMU 1 poo0o0o� 000000N ]000000F 0 0 0 0 0 0 `END CHT O4 C0%N021-5 WIRED TO GIF -1-5. `J 0000000 ,00000 X000000 0. 000000 0oop0o' 0. n�,rt r,-- 60"x24" IN 2 HOUR FIRE RATED ENCLOSURE FILE COP7 Plan review approval 13 subject to errors and omissions. Approval of construe ion documents does net authorize the violation of any adopted coda or ordinance. Receipt of approved Field Copy and conditions is ac mowladyed: By: Date: /fV/%‘. /2,0( City of Tukwila UILDINGG DIVISION i`7C .: City of BUl! C'' 7 PIR ; END SWITCH WIRED TO G ON Co/N021-4 -1-7. STAIR B S100B 174 SF TRASH/ RECYCLE ELEV 2 6"x10" FA ELEV. LOBBY ONDU N_SLABZABOVE BY CONTROLS CONTRACTOR. RING -1t1 --CONDUIT BY CONTROELCON`RACTOR. tf o00000e1 000000r °°0;i000 00t�� �k00c - 0 0• 7";=�50 C °°°0°°r 000000C�t 0000000{. 000000CY 000000CL REVISIONS No changes shall b' r =Ide to the Scope of work E.optoval of Tukwila Building NOTE: Revisions will req giro a submltta and may include additional flan r'eviev, fess ENCLOSED PARKING GARAGE VENTILATION: LEVEL 1: 23,126 S.F. 0 0.75 CFM PER SF = 17,350 CFM PROVIDE (3) 6,000 CFM GARAGE EXHAUST FANS GEF -1-1 TO GEF -1-3 FOR A TOTAL OF 18,000 CFM. REVISIONS DATE DESCRIPTION 12/19/2017 04/20/2018 05/24/2018 MECH. PERMIT REISSUED FOR MECH. PERMIT REVIEW SWI -IGH -R ,l- 161 SF LICATE INS JL A1ION) 3"o SUBBASE -TANK EMERGENCY 2"0 -SUBBASE TANK NORM VENT AL VENT 3"o SUBBASE TANK EMERGENCX PENT 2"0 FUEL\ FILL FROM FUEL ALL S A11ON I TO SUBBASE FUEL TANK. ` 1 1 1 I 1 i 000000 000000 000 00 C 0000000 RECEIVED CITY OF TUKWILA JUL 2 0 2018 PERMIT CENTER REVIEWED FOR DE COMPLIANCE APPROVED TRANSFORMER 492 SF DRAWING TITLE LEVEL 1 MECHANICAL 122 SF SLAB. TYPICAL. y v v v V \/ N/ / v v� i FIRE CONT. RM. 210 SF DATE MAY 2018 DRAWN BY DL SCALE 1.3 FUEL -FI ■ VTMIllir(SUPPLIED- BY ELECTRICAL CpNTRACTOR). MINIMUM 5'-0" FROM BUILbING OPENINGS. 750-kyA 1RANSF tER-NATURAL VENiitATtON- SHALLILBEi3'SQUARE INCHES PER kVA. MINIMUM 15.6 SQUARE Ftt i. 20 SQUARE FEET PROVIDED. M1.1 R7 THERMAL INSULATION ON OUTDOOR AIR DUCT. GAME ROOM '•TECH 217 #283, 14900 INTER URBAN AVE TELEPHONE 2066744553 SEATTLE, WA 98168 FACSIMILE 20.6744564 PROJECT STERLING SOUTHCENTER 415 BAKER BOULEVARD TUKWILA, WA 98188 -`1 - CORRIDOR 10"0 FLUE FB FIREPLACE INLINE POWER —VENTER BrOTHERS. EXHAUST N MAKE-UP AIR DUCTS FOR FUTURE 1C EN- HORIZONTAL DUCTING ON LEVEL 1 B 'ERS. 20"x24" NEPA 96 KITCHEN EXHAUST DUCT FA WITH FIRE RATED DUCT WRAP AND ACCESS PAN:L ON EACH FLOOR. 20"X24" MAIjE-UP AIR DUCT FA. 44"x14" TB. R7 THERMAL INSULATION ON OUTDOOR AIR DUCT. SEPARATION BETWEEN INTAKE __AND_EXHAUS.T:_MINIMUM AND MAXIMUM 5-0". EXHAUST 6" MINIMUM FROM WALL. INTAKE TO BE A DOWNTURN ELBOW. RESIDENTIAL PARKING is # - 1 I -- - I + - U , — — - is , Im - U I _ 1 I -- ----- I + - U 0/NO 2� / U — — 0 0 , 0 0 U 1 _ 111/211310100" . CONDUIT IN SLAB ABOVE BY CONTROLS CONTRACTOR. WIRING IN CONQUIT BY CONTROLS CONTRACTOR. 12/19/2017 MECH. PERMIT 04/20/2018 REISSUED FOR MECH. PERMIT 05/24/2018 REVIEW LEVEL 1: 23,126 S.F. 0 0.75 CFM PER SF = 17,350 CFM LEVEL 2: 27,915 S.F. 0 0.75 CFM PER SF = 20,940 CFM LEVEL 1 & 2: TOTAL OF 38,400 CFM PROVIDE (3) 12,800 CFM GARAGE EXHAUST FA GEF -2-1 TO GEF -2-3 FOR A TOTAL OF 38, RECEIVED CITY OF TUKWILA FANS SUSPENDED FROM STRUCTURE WITH 2" STATIC DEFLECTION SPRING ISOLATION HANGERS. VFDs FOR GARAGE EXHAUST FANS GEF -2-1 TO GEF -2-3 MOUNTED VERTICALLY ON WALL. 1"0 CONDUIT -END SWITCH Od CO/N022-6 WIRED TO GTE -12-6. NOTES: GARAGE -EXHAUST -LOUVER: — MINIMUM 3'-0" TO OPERABLE OPENINGS. 1. APARTMENTS SHALL HAVE A VERTICAL TERMINAL HEAT PUMP (V1HP). SUPPLY AIR GRILLES SHALL BE TYPE S-1 (UVING ROOM - 12"x8", BEDROOM - 12"x6"). FLEXIBLE DUCT TO GRILLES (LIVING ROOM - 10"0, BEDROOM - 8"0). 2. APARTMEtTS SHALL HAVE 750 W ELECTRIC HEATERS IN EACH BEDROOM. HEATERS TO BE SUPPLIED AND INSTALLED BY THE ELECTRICAL CONTRACTOR. HEATER SHALL BE INTERLOCKED TO THE VTAC TO ENSURE THAT SIMULTANEOUS HEATING AND COOLING DOES NOT OCCUR PER 2015 WSEC SE TION C403.2.4.1. 3. KITCHEN EXHAUST DUCTS SHALL BE CONSTRUCTED OF 6"0 GALVANIZED STEEL WITH SMOOTH INTERIOR(IFINISH AND TO BE AIR TIGHT. 4. DRYER DtECTING SHALL BE 4"0 SMOOTH METAL INTERIOR FINISH. IT SHALL BE EQUIPPED WITH BACKDRA DAMPER. NO SCREWS. 5. TOILET RQOM DUCTING SHALL BE CONSTRUCTED OF 5'0 GALVANIZED STEEL WITH SMOOTH INTERIOR FINISH AND TO BE AIR TIGHT. DUCT SERVING MULTIPLE TOILET ROOM FAN(S) SHALL BE 6"0. 6. KITCHEN, DRYER, TOILET ROOM EXHAUST HOOD SHALL BE 3'-0" FROM ANY OPERABLE OPENINGS. (EXHAUS1I HOOD BY OTHERS). 7. OUTDOOR AIR TO APARTMENTS THROUGH WINDOW TRICKLE VENTS (SUPPLIED BY OTHERS). 1 BEDROQM APARTMENTS: THREE (3) TITON TRIM VENT SM (4 SQ.IN. EACH). 2 BEDROOM APARTMENTS: FIVE (5) TITON TRIM VENT SM (4 SQ.IN. EACH). 8. DRYER SETS SHALL HAVE A 20" WIDE x 14' HIGH GRILLE IN EACH DOOR. 9. INTERIOR EDROOMS SHALL HAVE MECHANICAL » IATION. TRANSFER FAN 1F-1. 10. -DR E .WHIRLP-001-MODEL- VENT (SUPPUED BY OWNER). MAXIMUM DUCT LENGTH I$ 160 FEET WITH NO 90' ELBOWS. SU. t ..' 10 I-tti FROM MAXIMUM LENGTH FOR EACH 90' ELBOW. {''5coq5