Loading...
HomeMy WebLinkAboutPermit M18-0104 - LOWE'S - ROOFTOP A/C UNIT REPLACEMENTSLOWE'S 101 ANDOVER PARK E EXPIRED 07/15/2019 M18-0104 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-43:L-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov 0223000030 101 ANDOVER PARK E Project Name: LOWE'S MECHANICAL PERMIT Permit Number: M18-0104 Issue Date: 11/1/2018 Permit Expires On: 4/30/2019 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: LOWE'S HOME CENTERS LLC 1000 LOWE'S BLVD NBTA, MOORESVILLE, TX, 28117 KERRY BURR 601 DEVELOPMENT DR , PLANO, TX, 75074 NEXREV LLC 601 DEVELOPMENT DR , PLANO, TX, 75074 NEXREL*830RM II I Phone: (972) 578-0505 Phone: Expiration Date: 12/14/2019 DESCRIPTION OF WORK: REPLACE (21) PACKAGED ROOFTOP AIR-CONDITIONING UNITS. ALL LIKE FOR LIKE. Valuation of Work: $133,000.00 Type of Work: REPLACEMENT Fuel type: ELECT Fees Collected: $1,815.37 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Date `k'`�I I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. �/ Signature: �l�j' Date: l� Q��15 Print Name: 4/(7/av-, /vnlo This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: The attached set of mechanical plans have been reviewed by The Tukwila Fire Marshals Office and are acceptable with the following concerns: 2: H.V.A.C. units rated at greater than 2,000 cfm require auto -shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2437) 3: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air -moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 4: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2437) 5: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2437) 6: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 7: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 8: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 9: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 10: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. 11: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 12: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 13: Readily accessible access to roof mounted equipment is required. 14: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 15: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 16: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). t� 4 17: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 18: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 19: ***MECHANICAL PERMIT CONDITIONS*** 20: All mechanical work shall be inspected and approved under Permit Center (206/431-3670). 21: Manufacturers installation instructions shall be available on PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1400 0703 1800 0705 0701 0702 FIRE FINAL MECH EQUIP EFF MECHANICAL FINAL REFRIGERATION EQUIP ROUGH -IN MECHANICAL SMOKE DETECTOR TEST a separate permit the job site at the issued by the City of Tukwila time of inspection. CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. tI\ Project No. Date ApplicationAcaept Date Application Expires: (Par q use on ) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION King Co Assessor's Tax No.: Site Address: 101I1 Y fldo\jtr?i u,rK East Suite Number: Floor: LTenant Name: ou ,$ New Tenant: ❑ Yes No PROPERTY OWNER �� _ i� _.... Name: h e r Yy �-�V .� Address:te bl G� v. 17 �-�OptY�el'� hri Name: )_ w Phone: Q -j7 .s 7 %- - Fax: 9,7z.4.76_ o n s Email: Lfi?p tJq rev • torr Address:1 05 .. r , t ��JJ..�. l r �l'J•■■\UVJ State: ^ , Zip:Q CONTACT PERSON — person receiving all project communication �� _ i� _.... Name: h e r Yy �-�V .� Address:te bl G� v. 17 �-�OptY�el'� hri city. 0 State:Tx ZiptIscp An L Phone: Q -j7 .s 7 %- - Fax: 9,7z.4.76_ o n s Email: Lfi?p tJq rev • torr MECHANICAL CONTRACTOR INFORMATION Company Name: cx tCV i L L� Address: %0D) `---.b Y/N1 LL e t—br. eve.,ioipmr�- City: cn Q State: --rx Zip Lit Phone: g7 576. Fax 02 576_0i-15 Contr Reg No.: NEXn etominiate: i Zi q /Iq .•v �C Tukwila Business License No.: Valuation of project (contractor's bid price): $ 1 3 J 00 v Describe the scope of work in detail: W lt., ltI bt- lno z 0. C,kQ � �o p - �and� cxi► t (,nl �S cuu ti Kt_ t.xn iK . Use: Residential: New ❑ Replacement ❑ . Commercial: New ❑ Replacement Fuel Type: Electric ❑ Gas ❑ Other: II:\AppIicatiom\Forms-Applications On Line \2016 Aplicationn\Mccluuucal Permit Application Revised I-0-16.docx Revised: January 2016 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Residential, Nighttime Furnace >100k btu industrial Floor furnace 55 dB(A) Suspended/wall/floor mounted heater 57 dB(A) Appliance vent Commercial Repair or addition to heat/refrig/cooling system �1 Air handling unit 65 dB(A) <10,000 cfm 60 dB(A) Unit Type Qty Air handling unit Residential, Nighttime >10,000 cfm industrial Ev • 'orator cooler 55 dB(A) Ventilation fan connected to single duct 57 dB(A) Ventilation system Commercial Hood and duct �1 Incinerator — domestic 65 dB(A) Incinerator — comm/:industrial 60 dB(A) Unit Type Qty Fire damper Residential, Nighttime Diffuser industrial Thermostat 55 dB(A) Wood/gas stove 57 dB(A) Emergency generator Commercial Other mechanical equipment �1 60 dB(A) 65 dB(A) Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu aci'ugcd F Noise: p AAt-(�t�(�uj�tCmri•t unci% C� i %� iw ):Ie 1 — ScL &ki4.L 4 Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum ermiss sound levels are based on fratb where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-1 OPM, Monday through Friday and 8AM-10PM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: • Warning devices; • Construction and property maintenance during the daytime hours (lam-IOpm); • Testing of backup generators during the day. PERMIT APPLICATION NOTES - we Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension off time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). 1 HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING r R AUTHORIZED AGENT: Signature: Print Name: Mailing Address: 1 Date: 8' i I i Day Telephone: " 1 a -s78 (:)Sbc" \ L* Drift, ,no -TX "isti7Li n:\ Applicatinm\Fmms-Application On Line \2016 Amdicatinns\Mcchanical Pcrmit Application Revised I-0-l6.dncx Revised January 2016 bh City State Zip Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID 1,815.37 Apn: 0223000030$1,815.37 M18-0104 Address: 101 ANDOVER PARK E MECHANICAL $1,745.55 PERMIT ISSUANCE BASE: FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $1,363.29 PLAN CHECK FEE R000.322.102.00.00 0.00 $349.11 TECHNOLOGY FEE $69.82 TECHNOLOGY FEE R000.322.900.04.00 0.00 $69.82 TOTAL FEES PAID BY RECEIPT: R15211 $1,815.37 Date Paid: Tuesday, August 21, 2018 Paid By: NEXREV LLC Pay Method: CHECK 28881 Printed: Tuesday, August 21, 2018 12:28 PM 1 of 1 SYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION /116 o 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Project:/��� 104" 1%S Type of Inspection: /I%iLk'! CX(.-. 74-7411 Ar_ Address: 40/ AuA t- Poe /L Date Called: SpeEtial Instructions: ao2A Date Wanted: Requester: � Phone No: 2-14, 5t3S bra Approved per applicable codes. orrections required prior to approval. COMMENTS: h� W -01/N1 Inspector: Date: REINSPEtTIONI FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. REVIEWED FOR CODE COMPLIANCE APPROVED OC1� 10 2018 City of Tukwila BUILDING DIVISION li51tO9 0 NTRAL • KANSAS CITY, MO 64105 (8 ) 421-4200 • WWW.JBAENGR.COM J JOHNSTON BURKHOLDER ASSOCIATES consulting structural engineers STRUCTURAL CALCULATIONS FOR LOWE'S REMODEL STORE #0010 Tukwila, WA Project #18092 06/20/18 GOBRE 11t LT R# cay of -- SEP i~ SEP 2 6 2°18 pERMil ;EN `''R Johnston BurkholderAssociates CONSULTING STRUCTURAI. ENGINEERS 930 CENTRAL • KANSAS CITY, MO 64105 PHONE 1816) 421-4200 • FAN (0I6) 421-4381 PROJECT NO. SHEET NO: OF: PROJECT NAME: DV 1v MADE BY: DATE: CHECKED BY: OATS —) Ct4CK . t H "7W &f f ' n -t " ".Act I r' A i L 5vff6It f f !' t2. 0/V Title Block Line 1 You can changes this area using the "Settings" menu item and then using the "Printing & Title Block" selection. Title Block Line 6 Steel Beam Lic. # : KW -06001782 Description : Beam at RTU -5,7 CODE REFERENCES Project Title: Engineer: Project ID: Project Descr: Printed: 20 JUN 2018, 10:35AM File = \UBA-APP1\Lowes\SREMOD-1\1-PROD-X10000-0-1\0010-T-112018-1-1\Engr118092.ecf Licensee : JOHNSTON - BURKHOLDER Calculations per AISC 360-10, IBC 2015, CBC 2016, ASCE 7-10 Load Combination Set : ASCE 7-10 Material Properties Analysis Method : Allowable Strength Design Beam Bracing : Beam is Fully Braced against lateral -torsional buckling Bending Axis : Major Axis Bending Fy : Steel Yield : E: Modulus : 50.0 ksi 29,000.0 ksi Span I. 6.50 fti Span • 40.0 ft Span-6.50ftt, Applied Loads Service Toads entered. Load Factors will be applied for calculations. Beam self weight NOT intemally calculated and added Load for Span Number 1 Uniform Load : D = 0.120, S = 0.1750 k/ft, Tributary Width = 1.0 ft Point Load: D = 2.010, S = 2.931 k @ 0.0 ft Load for Span Number 2 Uniform Load : D = 0.120, S = 0.1750 k/ft, Tributary Width = 1.0 ft Point Load : D = 0.7540 k @ 10.90 ft, (RTU) Load for Span Number 3 Uniform Load : D = 0.120, S = 0.1750 k/ft, Tributary Width = 1.0 ft Point Load : D =1.620, S = 2.360 k @ 6.50 ft DESIGN SUMMARY Maximum Bending Stress Ratio = Section used for this span Ma : Applied Mn / Omega : Allowable Load Combination Location of maximum on span Span # where maximum occurs Maximum Deflection Max Downward Transient Deflection Max Upward Transient Deflection Max Downward Total Deflection Max Upward Total Deflection 0.463: 1 W14x22 38.348 k -ft 82.834 k -ft +D+S+H 6.500ft Span # 1 Maximum Shear Stress Ratio = Section used for this span Va : Applied Vn/Omega : Allowable Load Combination Location of maximum on span Span # where maximum occurs 0.497 in Ratio = -0.043 in Ratio = 1.062 in Ratio = -0.171 in Ratio = 965 >=240 3,621 >=240 452 >=180 912 >=180 Design OK 0.109 : 1 W14x22 6.859 k 63.020 k +D+S+H 6.500 ft Span # 1 Title Block Line 1 You can changes this area using the "Settings" menu item and then using the "Printing & Title Block" selection. Title Block Line 6 Steel Beam Lic. # : KW -06001782 Description : Beam at RTU -3 CODE REFERENCES Project Title: Engineer: Project ID: Project Descr: Printed: 20 JUN 2018, 10:35AM File =1U BA-APP1 \Lowes\SREMOD-1 \1-PROJ-110000-0-1\0010-T-112018-1-1 \Engr\18092.ecf Licensee : JOHNSTON - BURKHOLDER Calculations per AISC 360-10, IBC 2015, CBC 2016, ASCE 7-10 Load Combination Set : ASCE 7-10 Material Properties Analysis Method : Allowable Strength Design Beam Bracing : Beam is Fully Braced against lateral -torsional buckling Bending Axis : Major Axis Bending Fy : Steel Yield : E: Modulus : 50.0 ksi 29,000.0 ksi _Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT intemally calculated and added Uniform Load : D = 0.120, S = 0.1750 k/ft, Tributary Width = 1.0 ft Point Load : D = 1.560 k @ 3.50 ft, (RTU) Point Load : D = 1.560 k @ 10.50 ft, (RTU) DESIGN SUMMARY Maximum Bending Stress Ratio Section used for this span Ma : Applied Mn / Omega : Allowable Load Combination Location of maximum on span Span # where maximum occurs Maximum Deflection Max Downward Transient Deflection Max Upward Transient Deflection Max Downward Total Deflection Max Upward Total Deflection 0.470: 1 W14x22 38.911 k -ft 82.834 k -ft +D+S+H 10.723ft Span # 1 Maximum Shear Stress Ratio = Section used for this span Va : Applied Vn/Omega : Allowable Load Combination Location of maximum on span Span # where maximum occurs 0.364 in Ratio = 0.000 in Ratio = 0.867 in Ratio = 0.000 in Ratio = 889 >=240 0 <240 374 >=180 0 <180 Design OK 0.100 : 1 W14x22 6.294 k 63.020 k +D+S+H 0.000 ft Span # 1 Title Block Line 1 You can changes this area using the "Settings" menu item and then using the "Printing & Title Block" selection. Title Block Line 6 Wood Beam Lic. # : KW -06001782 Description : 4x8 RTU framing member CODE REFERENCES Project Title: Engineer: Project ID: Project Descr: Printed: 20 JUN 2018, 10:35AM File=1UBA-APP11Lowes1SREMOD-111-PROD-110000-0-110010-T-112018-1-11Engr118092.ecE Licensee : JOHNSTON - BURKHOLDER Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10 Load Combination Set : ASCE 7-10 Material Properties Analysis Method : Allowable Stress Design Load Combination ASCE 7-10 Fb + Fb - Fc - PrIl Wood Species : Douglas Fir -South Fc - Perp Wood Grade : Construction Fv Ft Beam Bracing : Beam is Fully Braced against lateral -torsional buckling 975 psi 975 psi 1650 psi 520 psi 180 psi 600 psi E : Modulus of Elasticity Ebend- xx 1200 ksi Eminbend - xx 440ksi Density 28.7 pcf 1' D(0.156) 4x8 Span = 10.011 .1 r Applied Loads Beam self weight calculated and added to loads Uniform Load : D = 0.1560 , Tributary Width = 1.0 ft DESIGN SUMMARY Service loads entered. Load Factors will be applied for calculations. Maximum Bending Stress Ratio Section used for this span fb : Actual FB : Allowable Load Combination Location of maximum on span Span # where maximum occurs Maximum Deflection Max Downward Transient Deflection Max Upward Transient Deflection Max Downward Total Deflection Max Upward Total Deflection 0.898 1 4x8 787.91 psi 877.50 psi +D+H 5.000ft Span # 1 Maximum Shear Stress Ratio Section used for this span fv : Actual Fv : Allowable Load Combination Location of maximum on span Span # where maximum occurs 0.000 in Ratio = 0.000 in Ratio = 0.273 in Ratio = 0.000 in Ratio = Maximum Forces & Stresses for Load Combinations Load Combination Segment Length Max Stress Ratios Span # M V Cd C FN C i Cr 0 <240 0 <240 439 >=180 0 <180 Desi. n OK 0.260: 1 4x8 42.04 psi 162.00 psi +D+H 0.000 ft Span # 1 +D+H Length = 10.0 ft +D+L+H Length =10.0 ft Length = 10.0 ft +D+S+H Length = 10.0 ft +D+0.750Lr+0.750L+H 1 0.898 0.260 0.90 1.000 1.00 1.00 1.000 1.00 1.00 1 0.808 0.234 1.00 1.000 1.00 1.00 1.000 1.00 1.00 1 0.646 0.187 1.25 1.000 1.00 1.00 1.000 1.00 1.00 1 0.703 0.203 1.15 1.000 1.00 1.00 1.000 1.00 1.00 Moment Values Shear Values Cm C t CL M fb F'b V fv F'v 0.00 0.00 0.00 0.00 1.00 1.00 1.00 2.01 787.91 877.50 0.71 42.04 162.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 1.00 1.00 1.00 2.01 787.91 975.00 0.71 42.04 180.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 1.00 1.00 1.00 2.01 787.91 1218.75 0.71 42.04 225.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 1.00 1.00 1.00 2.01 787.91 1121.25 0.71 42.04 207.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Title Block Line 1 You can changes this area using the "Settings" menu item and then using the "Printing & Title Block" selection. Title Block Line 6 Wood Beam Project Title: Engineer: Project ID: Project Descr: Printed: 20 JUN 2018, 10:35AM File =\\JBA-APP11Lowes\SREMOD-1\1-PROJ-1 X00010-0-110010-T-1\2018-1-1\Engr\18092.ecE Lic. # : KW -06001782 Licensee : JOHNSTON - BURKHOLDER Description : 4x8 RTU framing member Load Combination Max Stress Ratios Moment Values Shear Values Segment Length Span # M V Cd C FN C i Cr Cm C t CL M tb F'b V fv F'v Length = 10.0 ft 1 0.646 0.187 1.25 1.000 1.00 1.00 1.00 1.00 1.00 2.01 787.91 1218.75 0.71 42.04 225.00 +D+0.750L+0.750S+H 1.000 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 10.0 ft 1 0.703 0.203 1.15 1.000 1.00 1.00 1.00 1.00 1.00 2.01 787.91 1121.25 0.71 42.04 207.00 +D+0.60W+H 1.000 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 10.0 ft 1 0.505 0.146 1.60 1.000 1.00 1.00 1.00 1.00 1.00 2.01 787.91 1560.00 0.71 42.04 288.00 +D+0.70E+H 1.000 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 10.0 ft 1 0.505 0.146 1.60 1.000 1.00 1.00 1.00 1.00 1.00 2.01 787.91 1560.00 0.71 42.04 288.00 +D+0.750Lr+0.750L+0.450W+H 1.000 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length =10.0 ft 1 0.505 0.146 1.60 1.000 1.00 1.00 1.00 1.00 1.00 2.01 787.91 1560.00 0.71 42.04 288.00 +D+0.750L+0.750S+0.450W+H 1.000 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 10.0 ft 1 0.505 0.146 1.60 1.000 1.00 1.00 1.00 1.00 1.00 2.01 787.91 1560.00 0.71 42.04 288.00 +D+0.750L+0.750S+0.5250E+H 1.000 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 10.0 ft 1 0.505 0.146 1.60 1.000 1.00 1.00 1.00 1.00 1.00 2.01 787.91 1560.00 0.71 42.04 288.00 +0.60D+0.60W+0.60H 1.000 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 10.0 ft 1 0.303 0.088 1.60 1.000 1.00 1.00 1.00 1.00 1.00 1.21 472.75 1560.00 0.43 25.23 288.00 +0.60D+0.70E+0.60H 1.000 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length =10.0 ft 1 0.303 0.088 1.60 1.000 1.00 1.00 1.00 1.00 1.00 1.21 472.75 1560.00 0.43 25.23 288.00 Overall Maximum Deflections Load Combination Span Max. " Defl Location in Span Load Combination Max. "+" Defl Location in Span D Only r Vertical Reactions 1 0.2733 5.036 0.0000 0.000 Support notation : Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Overall MAXimum 0.805 0.805 Overall MINimum 0.805 0.805 +D+H 0.805 0.805 +04+1-1 0.805 0.805 +D+4r+H 0.805 0.805 +D+S+H 0.805 0.805 +D+0.750Lr+0.750L+H 0.805 0.805 +D+0.750L+0.750S+H 0.805 0.805 +D+0.60W+H 0.805 0.805 +D+0.70E+H 0.805 0.805 +D+0.750Lr+0.750L+0.450W+H 0.805 0.805 +D+0.750L+0.750S+0.450W+H 0.805 0.805 +D+0.750L+0.750S+0.5250E+H 0.805 0.805 +0.60D+0.60W+0.60H 0.483 0.483 +0.60D+0.70E+0.60H 0.483 0.483 D Only 0.805 0.805 Lr Only L Only S Only W Only E Only H Only Title Block Line 1 You can changes this area using the "Settings" menu item and then using the "Printing & Title Block" selection. Title Block Line 6 Steel Beam Lic. # : KW -06001782 Description : RTU support Member - Channel CODE REFERENCES Project Title: Engineer: Project ID: Project Descr: Printed: 20 JUN 2018, 10:35AM File=1UBA-APPllowes1SREMOD-111-PROD-10000-0-110010-T-112018-1-11Engt118092.ecf Licensee : JOHNSTON - BURKHOLDER Calculations per AISC 360-10, IBC 2015, CBC 2016, ASCE 7-10 Load Combination Set : ASCE 7-10 Material Properties Analysis Method : Allowable Strength Design Beam Bracing : Beam is Fully Braced against lateral -torsional buckling Bending Axis : Major Axis Bending Fy : Steel Yield : E: Modulus : 36.0 ksi 29,000.0 ksi f Span - 10.0 ft Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loading Uniform Load : D = 0.1560 k/ft, Tributary Width = 1.0 ft DESIGN SUMMARY Maximum Bending Stress Ratio = Section used for this span Ma : Applied Mn / Omega : Allowable Load Combination Location of maximum on span Span # where maximum occurs Maximum Deflection Max Downward Transient Deflection Max Upward Transient Deflection Max Downward Total Deflection Max Upward Total Deflection 0.121: 1 C8x11.5 2.094 k -ft 17.299 k -ft +D+}1 5.000ft Span # 1 Maximum Shear Stress Ratio = Section used for this span Va : Applied Vn/Omega : Allowable Load Combination Location of maximum on span Span # where maximum occurs 0.000 in Ratio = 0.000 in Ratio = 0.040 in Ratio = 0.000 in Ratio = 0 <240 0 <240 2987 >=180 0 <180 Design OK 0.037 : 1 C8x11.5 0.8375 k 22.764 k 0.000 ft Span # 1 Title Block Line 1 You can changes this area using the "Settings" menu item and then using the "Printing & Title Block" selection. Title Block Line 6 Wood Beam Lic. # : KW -06001782 Description : Wood Purlin at RTU CODE REFERENCES Project Title: Engineer: Project ID: Project Descr: Printed: 20 JUN 2018, 10:35AM File=11JBA-APP11Lowes\SREMOD-111-PROJ-1t0000-0-110010-T-1\2018-1-11Engr118092.ecE Licensee : JOHNSTON - BURKHOLDER Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10 Load Combination Set : ASCE 7-10 Material Properties Analysis Method : Allowable Stress Design Load Combination ASCE 7-10 Wood Species Wood Grade : SP/SP : 24F - V4 Fb + 2400 psi Fb - 1650 psi Fc - PrII 1350 psi 650 psi 210 psi 975 psi Fc - Perp Fv Ft Beam Bracing : Beam is Fully Braced against lateral -torsional buckling E : Modulus of Elasticity Ebend- xx Eminbend - xx Ebend- yy Eminbend - yy Density 1 700 ksi 900 ksi 1500 ksi 790 ksi 34.32 pcf 1' D(0.I779) D(0.081 S(0.2)1 3.125 X 25.50 Span =40.0ft Applied Loads Beam self weight calculated and added to loads Uniform Load : D = 0.080, S = 0.20 , Tributary Width = 1.0 ft Point Load : D = 0.7790 k @ 12.250 ft Point Load : D = 0.7790 k @ 22.250 ft DESIGN SUMMARY Service loads entered. Load Factors will be applied for calculations. Maximum Bending Stress Ratio Section used for this span fb : Actual FB : Allowable Load Combination Location of maximum on span Span # where maximum occurs Maximum Deflection Max Downward Transient Deflection Max Upward Transient Deflection Max Downward Total Deflection Max Upward Total Deflection = 1.005 1 3.125 X 25.50 2,533.50 psi = 2,521.58 psi +D+S+H = 20.292ft Span # 1 Maximum Shear Stress Ratio Section used for this span fv : Actual Fv : Allowable Load Combination Location of maximum on span Span # where maximum occurs 1.578 in Ratio = 0.000 in Ratio = 2.799 in Ratio = 0.000 in Ratio = Maximum Forces & Stresses for Load Combinations Max Stress Ratios Span # M V Cd C FN C i Cr Load Combination Segment Length 304 >=240 0 <240 171 <180 0 <180 Design N.G. 0.488: 1 3.125 X 25.50 117.74 psi = 241.50 psi +D+S+H 0.000 ft = Span # 1 Cm C CL Moment Values M fb Shear Values F'b V fv F'v +D+H Length = 40.0 ft +D+L+H Length = 40.0 ft 1 0.566 0.265 0.90 0.914 1.00 1.00 1.00 1.00 1.00 31.54 0.914 1.00 1.00 1.00 1.00 1.00 1 0.510 0.239 1.00 0.914 1.00 1.00 1.00 1.00 1.00 31.54 0.00 1,117.58 1973.41 0.00 1,117.58 2192.68 0.00 0.00 0.00 2.66 50.14 189.00 0.00 0.00 0.00 2.66 50.14 210.00 Title Block Line 1 You can changes this area using the "Settings" menu item and then using the "Printing & Title Block" selection. Title Block Line 6 Wood Beam Project Title: Engineer: Project ID: Project Descr: Printed: 20 JUN 2018, 10:35AM File =\UBA-APP1\Lowes\SREMOD-1\1-PROJ-110000-0-110010-T-1\2018-1-11Engr118092.ecE Lic. # : KW -06001782 Licensee : JOHNSTON - BURKHOLDER Description : Load Combination Wood Purlin at RTU Max Stress Ratios Moment Values Shear Values Segment Length Span # M V Cd C FN Ci Cr Cm C t CL M fb F'b V fv F'v +D+Lr+11 0.914 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 40.0 ft 1 0.408 0.191 1.25 0.914 1.00 1.00 1.00 1.00 1.00 31.54 1,117.58 2740.85 2.66 50.14 262.50 +D+S+H 0.914 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 40.0 ft 1 1.005 0.488 1.15 0.914 1.00 1.00 1.00 1.00 1.00 71.50 2,533.50 2521.58 6.25 117.74 241.50 +D+0.750Lr+0.750L+H 0.914 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 40.0 ft 1 0.408 0.191 1.25 0.914 1.00 1.00 1.00 1.00 1.00 31.54 1,117.58 2740.85 2.66 50.14 262.50 +D+0.750L+0.750S+H 0.914 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 40.0 ft 1 0.864 0.418 1.15 0.914 1.00 1.00 1.00 1.00 1.00 61.51 2,179.33 2521.58 5.36 100.84 241.50 +D+0.60W+H 0.914 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 40.0 ft 1 0.319 0.149 1.60 0.914 1.00 1.00 1.00 1.00 1.00 31.54 1,117.58 3508.29 2.66 50.14 336.00 +D+0.70E+H 0.914 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 40.0 ft 1 0.319 0.149 1.60 0.914 1.00 1.00 1.00 1.00 1.00 31.54 1,117.58 3508.29 2.66 50.14 336.00 +D+0.750Lr+0.750L+0.450W+H 0.914 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 40.0 ft 1 0.319 0.149 1.60 0.914 1.00 1.00 1.00 1.00 1.00 31.54 1,117.58 3508.29 2.66 50.14 336.00 +D+0.750L+0.7505+0.450W+H 0.914 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 40.0 ft 1 0.621 0.300 1.60 0.914 1.00 1.00 1.00 1.00 1.00 61.51 2,179.33 3508.29 5.36 100.84 336.00 +D+0.750L+0.7505+0.5250E+H 0.914 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 40.0 ft 1 0.621 0.300 1.60 0.914 1.00 1.00 1.00 1.00 1.00 61.51 2,179.33 3508.29 5.36 100.84 336.00 +0.60D+0.60W+0.60H 0.914 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 40.0 ft 1 0.191 0.090 1.60 0.914 1.00 1.00 1.00 1.00 1.00 18.92 670.55 3508.29 1.60 30.08 336.00 +0.60D+0.70E+0.60H 0.914 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 40.0 ft 1 0.191 0.090 1.60 0.914 1.00 1.00 1.00 1.00 1.00 18.92 670.55 3508.29 1.60 30.08 336.00 Overall Maximum Deflections Load Combination Span Max. •-• Defl Location in Span Load Combination Max. "+" Deli Location in Span +0+5+H Vertical Reactions 1 2.7990 20.000 0.0000 0.000 Support notation : Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Overall MAXimum Overall MINimum +D+H +D+L+H +D+Lr+H +D+S+H +D+0.750Lr+0.750L+H +D+0.750L+0.750S+H +D+0.60W+H +D+0.70E+H +D+0.750Lr+0.750L+0.450W+H +D+0.750L+0.7505+0.450W+H +D+0.750L+0.7505+0.5250E+H +0.60D+0.60W+0.60H +0.60D+0.70E+0.60H D Only Lr Only L Only S Only W Only E Only H Only 6.866 4.000 2.866 2.866 2.866 6.866 2.866 5.866 2.866 2.866 2.866 5.866 5.866 1.720 1.720 2.866 6.652 4.000 2.652 2.652 2.652 6.652 2.652 5.652 2.652 2.652 2.652 5.652 5.652 1.591 1.591 2.652 4.000 4.000 Project Information LENNOX) Product Submittal Project Name: LOWES #10 - TUKWILA WA Project Number: 3000786011 Project Location: 101 ANDOVER PARK EAST TUKWILA, WA 98188, US Project Altitude: 1000 Customer Information Company Name: Lowes Co Inc Company Address: 1605 CURTIS BRIDGE RD Company Location: WILKESBORO, NC 28697-2231 Contact: Phone: 336-658-4841 REVIEWED FOR CODE COMPLIANCE APPROVED • ULI 102018 City of Tukwila BUILDING DIVISION Engineering Information Company Name: Page Interworks Company Address: 320 B TENTH ST Company Location: NORTH WILKESBORO, NC 28659 Contact: Phone: 336-667-4225 RECEIVED CITY OF TUKWILA AUG 21 2018 PERM'? CEMTER We are pleased to provide the attached project submittal. If you have any questions or need additional information, please feel free to call our office. Project: 3000786011 LOWES #10 - TUKWILA WA Quote: 4000925551 LOWES #10 - TUKWILA WA Page 1 of 68 Ml&o10LI Last Changed: PENISTEN„ JR Prepared On: 2018-06-06 Phone: 972-497-6786 Lennox Industries Inc. - Product Submittal Table of Contents System ID Qty Model Description RTU -1,3,4,5,6,7 6 LGH210H4M PKGGE/17.5TON/CONFIGURABLE RTU -2 1 LGH240H4M PKGGE/20TON/CONFIGURABLE RTU -8 1 LCH036H4E PKGEE/3TON/COt4FIGURABLE RTU -17 1 LGH156H4M PKGGE/13TON/CONFIGURABLE RTU -19,21 2 LCH074H4T PKGEE/ETON/CO'_4FIGURABLE RTU -20 1 LCH120H4M PKGEE/10TON/CONFIGURABLE RTU -9 1 LGH036H4E PKGGE/3TON/CONFIGURABI.F RTU -10 1 LCH060H4E PKGEE/5TON/CONFIGURABLE RTU -11 1 LGH060H4E PKGGE/5TON/CONFIGURABLE RTU -12 1 LGH048H4E PKGGE/4TON/CONFIGURABLE RTU -13 1 LCH060H4E PKGEE/5TON/CONFIGURABLE RTU -15,16 2 LGH036H4E PKGGE/3TON/CONFIGURABLE RTU -18 1 LCH048H4E PKGEE/4TON/CONFIGURABLE d1 Project: 3000786011 LOWES #10 - TUKWILA WA Quote: 4000925551 LOWES #10 - TUKWILA WA Page 2 of 68 Last Changed: PENISTEN, JR Prepared On: 2018-06-06 Phone: 972-497-6786 Lennox Industries Inc. - Product Submittal System ID: RTU -1,3,4,5,6,7 Package Model: LGH210H4M Description: PKGGE/17.5TON/CONFIGURABLE HEATING PERFORMANCE Unit Type H/E LowInput H/E LowOutput H/E HighInput H/E HighOutput System HeatOutput Packaged Gas Electric 169000 (Btuh) 135200 (Btuh) 260000 (Btuh) 208000 (Btuh) 208000 (Btuh) Gas Supply Connection H/E Heat Rise AFUE/ ThermalEff Number of Heating Stages Gas Supply Pressure 1.00 (in.) 27.5 (°F) 80 2 7 (in.WC) COOLING PERFORMANCE Refrigerant ARI EER ARI LEER ARI Total Power ARI GrossTotalCool ARI NetTotalCool Coil GrossTotalCool Unit NetTotalCool Coil GrossSensCool Unit NetSensCool Tube/Fin Refrigerant Charge R -410A 12.0 14.0 16500 (W) 204000 (Btuh) 198000 (Btuh) 213395 (Btuh) 204498 (Btuh) 191469 (Btuh) 182572 (Btuh) 39 LBS. 0 OZ. Number Compressors Number of Cooling Stages Condensate Drain Size Cooling OutdoorDB Cooling MixedDB Cooling MixedWB Coil DischargeDB Coil DischargeWB Unit DischargeDB Unit DischargeWB Coil MoistureRemoval System MoistRemoval 3 2 1.00 (in.) 82.0 (°F) 80.0 (°F) 64.0 (°F) 53.1 (°F) 53.1 (°F) 54.4 (°F) 53.6 (°F) 20.7 (lb/hr) 20.7 (lb/hr) SUPPLY FAN PERFORMANCE Supply AirFlow ExtStaticPress Supply SupplyFan Req'dPower SupplyFan NomPower Supply Fan Type SupplyDriveReq'd RPM SupplyDrive Min RPM SupplyDrive Max RPM 7000 (cfm) 0.40 (in.WC) 3.08 (hp) 5.00 (hp) MSAV Belt Drive 780 (rpm) 685 (rpm) 856 (rpm) TotalStaticPress Wet Coil Static Press Gas H/E Static Press Added Filter Static Press Economizer Static Press Air Filter Qty Air Filter Length Air Filter Width Air Filter Thickness 0.67 (in.WC) 0.10 (in.WC) 0.09 (in.WC) 0.04 (in.WC) 0.04 (in.WC) 6 24.0 (in.) 24.0 (in.) 2.0 (in.) ELECTRICAL Voltage Frequency System MCA System MOCP Compressors RLA Cooling FLA Total Unit Oper Range -Nom Voltage 460V 3Ph 60 (Hz) 42.0 (amp) 45 (amp) 23.8 (amp) 39.2 (amp) +/- 10% SupplyFan FLA CondensingUnit FLA CondenserFan Power 7.6 (amp) 7.8 (amp) 1950 (W) DIMENSIONS Cabinet Width Cabinet Length Cabinet Height Total Weight 91.1 (in.) 132.6 (in.) 54.3 (in.) 2537 (lb) Downflow Supply Length Downflow Supply Width Downflow Return Length Downflow Return Width 20.0 (in.) 28.0 (in.) 15.0 (in.) 60.5 (in.) SOUND Outdoor Sound Rating 94 (db) Project: 3000786011 LOWES #10 - TUKWILA WA Quote: 4000925551 LOWES #10 - TUKWILA WA Page 3 of 68 Last Changed: PENISTEN, JR Prepared On: 2018-06-06 Phone: 972-497-6786 Lennox Industries Inc. - Product Submittal System ID: RTU -1,3,4,5,6,7 Package Model: LGH210H4M Description: PKGGE/17.5TON/CONFIGURABLE SYSTEM FEATURES Durable Outdoor Enamel Paint Finish Scroll Compressor Pre -charged Refrigeration System Expansion Valves High Capacity Driers Auto reset high & low pressure switch with strike 3 lockout feature in Prodigy unit controller Totally Enclosed Fan Motor PVC Coated Fan Guard Fan and Limit Controls Factory Test Operated Bonded for Grounding Internal Pressure Relief Valve Overload Protection Crankcase Heater Test Timed Off Control AGA -CGA Certified Units will operate cooling down to 0 degrees F (-17.7 degrees C) without additional controls. Redundant Comb. Gas Control Valve Electronic Flame Sensor Direct Spark Ignition Separate Compressor and Controls Compartment Advanced controls with Prodigy Control System Limited compressor warranty of 5 years Limited warranty on Prodigy Unit Controller of 3 years Limited warranty on all other components of 1 year See Limited Warranty Certificate included with unit for details INCLUDED SYSTEM OPTIONS - FACTORY INSTALLED SENSIBLE ECONOMIZER/W HOOD HIGH PERF ECONOMIZER 2 IN MERV8 FILTER BLOWER PROVING SWITCH CIRCUIT BREAKER CORROSION PROTECTION MULTI -STAGE AIR VOLUME HINGED ACCESS DOORS TUBE AND FIN COIL SYSTEM MSAV BLOWER BYPASS DIRTY FILTER SWITCH GFCI - FACTORY INSTALLED/NON-POWERED BAROMETRIC RELIEF DAMPERS/W HOOD PHASE MONITOR RA SMOKE DETECTOR STANDARD CAP NOVAR ETM -2051 Project: 3000786011 LOWES #10 - TUKWILA WA Quote: 4000925551 LOWES #10 - TUKWILA WA Page 4 of 68 Last Changed: PENISTEN, JR Prepared On: 2018-06-06 Phone: 972-497-6786 Lennox Industries Inc. - Product Submittal System ID: RTU -1,3,4,5,6,7 Package Model: LGH210H4M Description: PKGGE/17.5TON/CONFIGURABLE DIMENSIONS - INCHES (MM) CORNER WEIGHTS LGH21O, LGH24O, LGH300 CENTER OF GRAVITY Model No. AA BB CC DD EE FF Ibs. kg lbs. kg Ibs. kg Ibs. kg in. mm in. mm LGH210 Std. Unit 497 234 513 242 671 317 649 306 54-3/4 1391 39-1/2 1003 LGH210 Max. Unit 607 286 598 282 700 330 710 335 53-1/2 1359 42 1067 LGH240 Std. Unit 507 239 533 252 713 336 677 320 55-1/4 1403 39 991 LGH240 Max. Unit 617 291 620 292 741 350 738 348 54 1372 41-1/2 1054 LGH300 Std. Unit 513 242 535 252 739 349 709 334 55 1397 38-1/4 972 LGH300 Max. Unit 623 294 620 293 767 362 770 363 53-3/4 1365 40-3/4 1035 Std. Unit - The unit w$th NO OPTIONS. Max. Unit -The unit with ALL OPTIONS Instaited (Economizer, etc.) a-�as) 9) OPTIONAL DISCONNECT (Factory Installer 51 (129) 4 (102) I 541/ (1371 CONDENSATE DRAIN GAS SUPPLY INLET (Fa Boftan Gas SupplyQdy) 8 ° ° 141(4 (260) (5 7) (�) SIDE ELECTRICAL. INLETS 91-18(2315) (210) 3-1/4 (83) BAS END VIEW Project: 3000786011 LOWES #10 - TUKWILA WA Quote: 4000925551 LOWES #10 - TUKWILA WA Page 5 of 68 AA D 4 (102) 1-112 (38) 1238 (314) 4-1/4j 108) T 60.1/2 (1537) 15 (381) i BOTTC61RETURN AIR OPENNG 1B (461) BOTTOM SUPPLY AIR OPENNGS a n �/ (314) (711) (114)+_(7 1) (lt/g4 /1/ 20(508) + 20 (508)V&./ of BB EE 1\ CENTER GRAVITY FF L■ nQ�l BOTTOM POWER ENTRY 6X8Nches(127X2133mm) TOP VIEW 6.'"& OPTIONAL 115 VOLT OUTLET (Factory Installed Inside Unt) 132.58 (3369) CC 6 (152) LFIING HOLES (FaR Frac and ) FORKLFT SLOTS (Fart and Left Side Only) 107314 (2737) BASE SIDE VIEW Last Changed: PENISTEN, JR Prepared On: 2018-06-06 Phone: 972-497-6786 253/8 (645) i Lennox Industries Inc. - Product Submittal System ID: RTU -2 Package Model: LGH240H4M Description: PKGGE/20TON/CONFIGURABLE ACCESSORY DIMENSIONS - INCHES (MM) OPTIONAL OUTDOOR AIR HOOD DETAIL WITH STANDARD STATIC POWER EXHAUST FANS 10 O�NAL NR HOOD vet Ecortedzet or O or Alt Mt -yet OPTIONAL rib tweed) Project: 3000786011 LOWES #10 - TUKWILA WA Quote: 4000925551 LOWES #10 - TUKWILA WA Page 11 of 68 Last Changed: PENISTEN, JR Prepared On: 2018-06-06 Phone: 972-497-6786 Lennox Industries Inc. - Product Submittal System ID: RTU -1,3,4,5,6,7 Package Model: LGH210H4M Description: PKGGE/17.5TON/CONFIGURABLE UNIT CLEARANCES - INCHES (MM) Unit With Economizer O/ 11. Note: 210-240-300 sizes shown ' Unit Clearance A B C D Top Clearance in. mm in. mm in. mm in. mm Service Clearance 60 1524 36 914 36 934 66 1676 Unobstructed Clearance to Combustibles 36 914 1 25 1 25 1 25 Minimum Operation Clearance 45 1143 36 914 36 914 41 1041 NOTE - Entire perimeter of trrit base requires stivortwhen elevated above the mounting surface. S.fvice Clearance - Required for removal of serviceable parts. Clearance to Combustibles - Required cleardnce b combustible material. Minimum Operation Clearance - Required clearance for proper trait operation. Project: 3000786011 LOWES #10 - TUKWILA WA Quote: 4000925551 LOWES #10 - TUKWILA WA Page 7 of 68 Last Changed: PENISTEN, JR Prepared On: 2018-06-06 Phone: 972-497-6786 Lennox Industries Inc. - Product Submittal System ID: RTU -2 Package Model: LGH240H4M Description: PKGGE/20TON/CONFIGURABLE HEATING PERFORMANCE Unit Type H/E LowInput H/E LowOutput H/E HighInput H/E HighOutput System HeatOutput Packaged Gas Electric 169000 (Btuh) 135200 (Btuh) 260000 (Btuh) 208000 (Btuh) 208000 (Btuh) Gas Supply Connection H/E Heat Rise AFUE/ ThermalEff Number of Heating Stages Gas Supply Pressure 1.00 (in.) 24.1 (°F) 80 2 7 (in.WC) COOLING PERFORMANCE Refrigerant ARI EER ARI IEER ARI Total Power ARI GrossTotalCool ARI NetTotalCool Coil GrossTotalCool Unit NetTotalCool Coil GrossSensCool Unit NetSensCool Tube/Fin Refrigerant Charge R -410A 12.0 14.5 19200 (W) 238000 (Btuh) 230000 (Btuh) 253940 (Btuh) 241519 (Btuh) 229562 (Btuh) 217141 (Btuh) 38 LBS. 12 OZ. Number Compressors Number of Cooling Stages Condensate Drain Size Cooling OutdoorDB Cooling MixedDB Cooling MixedWB Coil DischargeDB Coil DischargeWB Unit DischargeDB Unit DischargeWB Coil MoistureRemoval System MoistRemoval 4 2 1.00 (in.) 82.0 (°F) 80.0 (°F) 64.0 (°F) 51.8 (°F) 51.8 (°F) 53.2 (°F) 53.1 (°F) 23.0 (lb/hr) 23.0 (lb/hr) SUPPLY FAN PERFORMANCE Supply AirFlow ExtStaticPress Supply SupplyFan Req'dPower SupplyFan NomPower Supply Fan Type SupplyDriveReq'd RPM SupplyDrive Min RPM SupplyDrive Max RPM 8000 (cfm) 0.40 (in.WC) 4.30 (hp) 5.00 (hp) MSAV Belt Drive 859 (rpm) 850 (rpm) 1045 (rpm) TotalStaticPress Wet Coil Static Press Gas H/E Static Press Added Filter Static Press Economizer Static Press Air Filter Qty Air Filter Length Air Filter Width Air Filter Thickness 0.78 (in.WC) 0.13 (in.WC) 0.11 (in.WC) 0.05 (in.WC) 0.09 (in.WC) 6 24.0 (in.) 24.0 (in.) 2.0 (in.) ELECTRICAL Voltage Frequency System MCA System MOCP Compressors RLA Cooling FLA Total Unit Oper Range -Nom Voltage 460V 3Ph 60 (Hz) 50.0 (amp) 50 (amp) 32.0 (amp) 47.4 (amp) +/- 10% SupplyFan FLA CondensingUnit FLA CondenserFan Power 7.6 (amp) 7.8 (amp) 1950 (W) DIMENSIONS Cabinet Width Cabinet Length Cabinet Height Total Weight 91.1 (in.) 132.6 (in.) 54.3 (in.) 2637 (lb) Downflow Supply Length Downflow Supply Width Downflow Return Length Downflow Return Width 20.0 (in.) 28.0 (in.) 15.0 (in.) 60.5 (in.) SOUND Outdoor Sound Rating 94 (db) Project: 3000786011 LOWES #10 - TUKWILA WA Quote: 4000925551 LOWES #10 - TUKWILA WA Page 8 of 68 Last Changed: PENISTEN, JR Prepared On: 2018-06-06 Phone: 972-497-6786 Lennox Industries Inc. - Product Submittal System ID: RTU -2 Package Model: LGH240H4M Description: PKGGE/20TON/CONFIGURABLE SYSTEM FEATURES Durable Outdoor Enamel Paint Finish Scroll Compressor Pre -charged Refrigeration System Expansion Valves High Capacity Driers Auto reset high & low pressure switch with strike 3 lockout feature in Prodigy unit controller Totally Enclosed Fan Motor PVC Coated Fan Guard Fan and Limit Controls Factory Test Operated Bonded for Grounding Internal Pressure Relief Valve Overload Protection Crankcase Heater Test Timed Off Control AGA -CGA Certified Units will operate cooling down to 0 degrees F (-17.7 degrees C) without additional controls. Redundant Comb. Gas Control Valve Electronic Flame Sensor Direct Spark Ignition Separate Compressor and Controls Compartment Advanced controls with Prodigy Control System Limited compressor warranty of 5 years Limited warranty on Prodigy Unit Controller of 3 years Limited warranty on all other components of 1 year See Limited Warranty Certificate included with unit for details INCLUDED SYSTEM OPTIONS - FACTORY INSTALLED SENSIBLE ECONOMIZER/W HOOD HIGH PERF ECONOMIZER 2 IN MERV8 FILTER BLOWER PROVING SWITCH CIRCUIT BREAKER CORROSION PROTECTION MULTI -STAGE AIR VOLUME HINGED ACCESS DOORS TUBE AND FIN COIL SYSTEM MSAV BLOWER BYPASS DIRTY FILTER SWITCH GFCI - FACTORY INSTALLED/NON-POWERED BAROMETRIC RELIEF DAMPERS/W HOOD PHASE MONITOR RA SMOKE DETECTOR STANDARD CAP NOVAR ETM -2051 Project: 3000786011 LOWES #10 - TUKWILA WA Quote: 4000925551 LOWES #10 - TUKWILA WA Page 9 of 68 Last Changed: PENISTEN, JR Prepared On: 2018-06-06 Phone: 972-497-6786 Lennox Industries Inc. - Product Submittal System ID: RTU -2 • Package Model: LGH240H4M Description: PKGGE/20TON/CONFIGURABLE DIMENSIONS - INCHES (MM) CORNER WEIGHTS LGH210, LGH24O, LGH300 CENTER OF GRAVITY Model No. AA BB CC DD EE FF Ibs. kg Ibs. kg Ibs. kg Ibs. kg in. mm in. mm LGH210 Std. Unit 497 234 513 242 671 317 649 306 54-3/4 1391 39-112 1003 LGH210 Max. Unit 607 286 598 282 700 330 710 335 53-1/2 1359 42 1067 LGH240 Std. Unit 507 239 533 252 713 336 677 320 55-1/4 1403 39 991 LGH240 Max. Unit 617 291 620 292 741 350 738 348 54 1372 41-1/2 1054 LGH300 Std. Unit 513 242 535 252 739 349 709 334 55 1397 38-1/4 972 LGH300 Max. Unit 623 294 620 293 767 362 770 363 53-3/4 1365 40-3/4 1035 Std. Unit - The out with NO OPTIONS. Max. Unit -The unit with ALL OPTIONS Installed. (Economizer, etc.) 904,8 (2289) AA 12318 (314) 44/44009) 15 (381) BB 60.1/2 (1537) - BOTTOM RETURN AIR OPENING Tr BOTTOM SUPPLY P 1 R OPENINGS t45118 7) 4n 123+6 29 (, 4) 28 (314) 20 (508)1) �Q 1) EE ai SOF GRA/11Y FF 20 303) +'1 AT, DDI CC 4 (102) BOTTOM POWER ENIRY 6 X 8 inches (127 X 203 mm) TOP VIEW 132518 (3369) OPTIAL OPTIONAL DISCONNNECT 115 VOLT OUTLET (Factory Installed) (Factory Installed Inside Unt) 54.1/4 (1378) j GAS SUPPLY i4/2Pers. {/ INLET IE 283/4 (730) 91-1/8 (2315) BASE SIDE ELECTRICAL INLETS END VIEW Project: 3000786011 LOWES #10 - TUKWILA WA Quote: 4000925551 LOWES #10 - TUKWILA WA Page 10 of 68 84/4 (210) 3-4 (83) 60 FLUE OUTLET O 6 \ UFTING HOLES FORKLF.T SLOTS (152) F(FaanC_ SeCkkRipphq ) and (Front aLe* Side Only) ro i 107-3/4 (2737) BASE SIDE VIEW Last Changed: PENISTEN, JR Prepared On: 2018-06-06 Phone: 972-497-6786 253/8 (645) Lennox Industries Inc. - Product Submittal System ID: RTU -2 Package Model: LGH240H4M Description: PKGGE/20TON/CONFIGURABLE ACCESSORY DIMENSIONS • INCHES (MM) OPTIONAL OUTDOOR AIR HOOD DETAIL WITH STANDARD STATIC POWER EXHAUST FANS 10 {406) OUlf0OR Alii MOOD or °tabor At Miner OPTIONAL 'PPS WO Project: 3000786011 LOWES #10 - TUKWILA WA Quote: 4000925551 LOWES #10 - TUKWILA WA Page 11 of 68 Last Changed: PENISTEN, JR Prepared On: 2018-06-06 Phone: 972-497-6786 Lennox Industries Inc. - Product Submittal System ID: RTU -2 Package Model: LGH240H4M Description: PKGGE/20TON/CONFIGURABLE UNIT CLEARANCES - INCHES (MM) Unit With Economizer Note: 210-240-300 szes shown Unit Clearance A B C D Top Clearance In. mm In. mm in. mm in. mm Service Clearance 60 1524 36 914 36 934 66 1676 Unobstructed Clearance to Combustibles 36 914 1 25 1 25 1 25 Minimum Operation Clearance 45 1143 36 914 36 914 41 1041 NOTE - Entire perimeter of unit base requires support when elevated above the mounbng surface. Service Clearance - Required for removal of serviceable parts. Clearance to Combustibles - Required clearance b wettable material. Minimum Operation Clearance - Required clearance for proper reit operaibn. Project: 3000786011 LOWES #10 - TUKWILA WA Quote: 4000925551 LOWES #10 - TUKWILA WA Page 12 of 68 Last Changed: PENISTEN, JR Prepared On: 2018-06-06 Phone: 972-497-6786 Lennox Industries Inc. - Product Submittal System ID: RTU -8 Package Model: LCH036H4E Description: PKGEE/3TON/CONFIGURABLE HEATING PERFORMANCE Unit Type H/E HighOutput System HeatOutput Packaged Electric/Electri 19235 (Btuh) 19235 (Btuh) Electric Heater H/E Heat Rise 7.5 (kW) 14.8 (°F) COOLING PERFORMANCE Refrigerant ARI EER ARI SEER ARI Total Power ARI GrossTotalCool ARI NetTotalCool Coil GrossTotalCool Unit NetTotalCool Coil GrossSensCool Unit NetSensCool Tube/Fin Refrigerant Charge R -410A 12.8 18.0 2800 (W) 36600 (Btuh) 36000 (Btuh) 36670 (Btuh) 35478 (Btuh) 32600 (Btuh) 31408 (Btuh) 9 LBS. 1 OZ. Number Compressors Number of Cooling Stages Condensate Drain Size Cooling OutdoorDB Cooling MixedDB Cooling MixedWB Coil DischargeDB Coil DischargeWB Unit DischargeDB Unit DischargeWB Coil MoistureRemoval System MoistRemoval 1 2 1.00 (in.) 82.0 (°F) 80.0 (°F) 64.0 (°F) 53.3 (°F) 53.1 (°F) 54.3 (°F) 53.5 (°F) 3.8 (lb/hr) 3.8 (lb/hr) SUPPLY FAN PERFORMANCE Supply AirFlow ExtStaticPress Supply SupplyFan Req'dPower SupplyFan NomPower Supply Fan Type SupplyDriveReq'd RPM Motor Torque Pct 1200 (cfm) 0.40 (in.WC) 0.50 (hp) 0.50 (hp) MSAV Direct Drive 906 (rpm) 58 TotalStaticPress Wet Coil Static Press Electric H/E Static Press Added Filter Static Press Economizer Static Press Air Filter Qty Air Filter Length Air Filter Width Air Filter Thickness 0.59 (in.WC) 0.05 (in.WC) 0.06 (in.WC) 0.04 (in.WC) 0.04 (in.WC) 4 16.0 (in.) 20.0 (in.) 2.0 (in.) ELECTRICAL Voltage Frequency System MCA System MOCP Compressors RLA Cooling FLA Total Unit Oper Range -Nom Voltage 208V 1Ph 60 (Hz) 40.0 (amp) 40 (amp) 16.7 (amp) 25.1 (amp) +/- 10% SupplyFan FLA CondensingUnit FLA CondenserFan Power 4.3 (amp) 4.1 (amp) 160 (W) DIMENSIONS Cabinet Width Cabinet Length Cabinet Height Total Weight 47.0 (in.) 85.3 (in.) 38.9 (in.) 162 (lb) Downflow Supply Length Downflow Supply Width Downflow Return Length Downflow Return Width 20.0 (in.) 18.0 (in.) 29.0 (in.) 11.0 (in.) SOUND Outdoor Sound Rating 75 (db) Project: 3000786011 LOWES #10 - TUKWILA WA Quote: 4000925551 LOWES #10 - TUKWILA WA Page 13 of 68 Last Changed: PENISTEN, JR Prepared On: 2018-06-06 Phone: 972-497-6786 Lennox Industries Inc. - Product Submittal System ID: RTU -8 Package Model: LCH036H4E Description: PKGEE/3TON/CONFIGURABLE SYSTEM FEATURES Durable Outdoor Enamel Paint Finish Scroll Compressor Pre -charged Refrigeration System Expansion Valves High Capacity Driers Auto reset high & low pressure switch with strike 3 lockout feature in Prodigy unit controller Totally Enclosed Fan Motor PVC Coated Fan Guard Fan and Limit Controls Factory Test Operated Bonded for Grounding Internal Pressure Relief Valve Overload Protection Crankcase Heater Test Timed Off Control Units will operate cooling down to 0 degrees F (-17.7 degrees C) without additional controls. Separate Compressor and Controls Compartment Advanced controls with Prodigy Control System Limited compressor warranty of 5 years Limited warranty on Prodigy Unit Controller of 3 years Limited warranty on all other components of 1 year See Limited Warranty Certificate included with unit for details INCLUDED SYSTEM OPTIONS - FACTORY INSTALLED ELECTRIC HEAT SENSIBLE ECONOMIZER/W HOOD HIGH PERF ECONOMIZER 2 IN MERV8 FILTER BLOWER PROVING SWITCH CORROSION PROTECTION MULTI -STAGE AIR VOLUME HINGED ACCESS DOORS TUBE AND FIN COIL SYSTEM DIRTY FILTER SWITCH DISCONNECT - WEATHERPROOF GFCI - FACTORY INSTALLED/NON-POWERED BAROMETRIC RELIEF DAMPERS/W HOOD RA SMOKE DETECTOR STANDARD CAP NOVAR ETM -2051 Project: 3000786011 LOWES #10 - TUKWILA WA Quote: 4000925551 LOWES #10 - TUKWILA WA Page 14 of 68 Last Changed: PENISTEN, JR Prepared On: 2018-06-06 Phone: 972-497-6786 Lennox Industries Inc. - Product Submittal System ID: RTU -8 Package Model: LCH036H4E Description: PKGEE/3TON/CONFIGURABLE DIMENSIONS - INCHES (MM) CORKER WEIGHTS CENTER OF GRAVITY Model No. AA B8 CC DD EE FF lbs. kg lbs. kg tbs. kg lbs. kg in. mm in. mm LCH036 Base Unit 92 42 112 51 180 82 148 67 38.5 978 18 457 LCH036 Max. Unit 133 61 151 69 243 110 215 98 40 1016 18 457 LCH048 Base Unit 97 44 113 54 190 87 157 71 38.5 978 18 457 LCH048 Max. Unit 139 63 158 72 254 115 224 102 40 1016 18 457 LCH060 Base Unft 112 51 136 62 219 100 181 82 38.5 978 18 457 LCH060 Max. Unit 159 72 180 82 290 132 257 117 40 1016 18 457 LCH072 Base Unit 126 57 152 69 246 112 202 92 38.5 978 18 457 LCH072 Mau. Unit 168 76 190 86 308 139 270 123 40 1016 18 457 LCH074 Base Unit 126 57 152 69 248 112 202 92 38.5 978 18 457 LCH074 Max Un7 168 76 190 86 308 139 270 123 40 1016 18 457 Rase Usk -The era sib NO INTER/01 CP ine. mac the -1Muniugh ALL tNIERNALOPTIONS Yahaed StandadStatic Pamir Mast Fans, Ccdrab. sb.). Cbrs not Mud* accessalas bawd baht aretaa7paaereailau4 0 END MN Project: 3000786011 LOWES #10 - TUKWILA WA Quote: 4000925551 LOWES #10 - TUKWILA WA Page 15 of 68 11 LIMOPki 00,10 NQ! 011a 0in1ET 10•allarm TOP VIEW ) SIDE VIEW 1 M f0:11,71 CLOTS NOE2COA'AL 6.10 NOIRCIDITAL Via& MayEi loaf rkn BACK VIEW trltm Last Changed: PENISTEN, JR Prepared On: 2018-06-06 Phone: 972-497-6786 L.:1141.-.1Pg, 1 ..-j r•t • •1.1 9 zeas l�f ems mats BASE SIDE VIEW 1 M f0:11,71 CLOTS NOE2COA'AL 6.10 NOIRCIDITAL Via& MayEi loaf rkn BACK VIEW trltm Last Changed: PENISTEN, JR Prepared On: 2018-06-06 Phone: 972-497-6786 Lennox Industries Inc. - Product Submittal System ID: RTU -8 Package Model: LCH036H4E Description: PKGEE/3TON/CONFIGURABLE ACCESSORY DIMENSIONS - INCHES (MM) OUTDOOR NR HOOD DETAIL FOR OPTIONAL ECONOMIZER AND BAROMETRIC RELIEF DAMPERS (Down -Flow Applications) CPIIOHAL OUTDOOR AIR HOOD (Fu rn e0 uUh EOsr nizrl 1 t-3'41208{ 036 AN 046 15.341 OM 060 *iv 072 OPTIONAL BAROMETRIC REUEFHCOO t. Fumieied with Eeomni:r) OUTDOOR AIR HOOD FOR ECONOMIZER (Furnished) SIDE VIEW BAROMETRIC RELIEF HOOD FOR ECONOMIZER (Fumishsd) Model A B C O. in. mm in. mm M. mm 038.048 19-1/4 489 13 330 11-3/4 298 060.072 23-1/4 591 17 432 15-3/4 400 Project: 3000786011 LOWES #10 - TUKWILA WA Quote: 4000925551 LOWES #10 - TUKWILA WA Page 16 of 68 Last Changed: PENISTEN, JR Prepared On: 2018-06-06 Phone: 972-497-6786 Lennox Industries Inc. - Product Submittal System ID: RTU -8 Package Model: LCH036H4E Description: PKGEE/3TON/CONFIGURABLE UNIT CLEARANCES - INCHES (MM) 1 I OUTDOOR NR HOOD D B ' Unit Clearance A B C 0 Top Clearance in. mm In. mm In. mm in. mm Service Clearance 36 914 36 914 36 934 36 914 Unobstructed Minimum Operation Clearance 36 914 36 914 36 914 36 914 NOTE - Entire perimeter of unit base requires support when elevated above the mounting surface. Service Clearance - Required for removal of serviceable parts. Minimum Operation Clearance - Regti red clearance for proper unit operation. Project: 3000786011 LOWES #10 - TUKWILA WA Quote: 4000925551 LOWES #10 - TUKWILA WA Page 17 of 68 Last Changed: PENISTEN, JR Prepared On: 2018-06-06 Phone: 972-497-6786 Lennox Industries Inc. - Product Submittal System ID: RTU -17 Package Model: LGH156H4M Description: PKGGE/13TON/CONFIGURABLE HEATING PERFORMANCE Unit Type H/E HighInput H/E HighOutput System HeatOutput Packaged Gas Electric 169000 (Btuh) 135000 (Btuh) 135000 (Btuh) Gas Supply Connection H/E Heat Rise AFUE/ ThermalEff Number of Heating Stages Gas Supply Pressure 1.00 (in.) 24.0 (°F) 80 1 7 (in.WC) COOLING PERFORMANCE Refrigerant ARI EER ARI LEER ARI Total Power ARI GrossTotalCool ARI NetTotalCool Coil GrossTotalCool Unit NetTotalCool Coil GrossSensCool Unit NetSensCool Tube/Fin Refrigerant Charge R -410A 12.0 14.1 12700 (W) 156000 (Btuh) 152000 (Btuh) 159520 (Btuh) 155004 (Btuh) 139062 (Btuh) 134546 (Btuh) 30 LBS. 4 OZ. Number Compressors Number of Cooling Stages Condensate Drain Size Cooling OutdoorDB Cooling MixedDB Cooling MixedWB Coil DischargeDB Coil DischargeWB Unit DischargeDB Unit DischargeWB Coil MoistureRemoval System MoistRemoval 3 2 1.00 (in.) 82.0 (°F) 80.0 (°F) 64.0 (°F) 53.7 (°F) 53.0 (°F) 54.6 (°F) 53.4 (°F) 19.3 (lb/hr) 19.3 (lb/hr) SUPPLY FAN PERFORMANCE Supply AirFlow ExtStaticPress Supply SupplyFan Req'dPower SupplyFan NomPower Supply Fan Type SupplyDriveReq'd RPM SupplyDrive Min RPM SupplyDrive Max RPM 5200 (cfm) 0.40 (in.WC) 1.51 (hp) 3.00 (hp) MSAV Belt Drive 636 (rpm) 535 (rpm) 725 (rpm) TotalStaticPress Wet Coil Static Press Gas H/E Static Press Added Filter Static Press Air Filter Qty Air Filter Length Air Filter Width Air Filter Thickness 0.50 (in.WC) 0.02 (in.WC) 0.06 (in.WC) 0.02 (in.WC) 6 24.0 (in.) 24.0 (in.) 2.0 (in.) ELECTRICAL Voltage Frequency System MCA System MOCP Compressors RLA Cooling FLA Total Unit Oper Range -Nom Voltage 460V 3Ph 60 (Hz) 31.0 (amp) 35 (amp) 20.1 (amp) 28.8 (amp) +/- 10% SupplyFan FLA CondensingUnit FLA CondenserFan Power 4.8 (amp) 3.9 (amp) 1100 (W) DIMENSIONS Cabinet Width Cabinet Length Cabinet Height Total Weight 91.1 (in.) 106.5 (in.) 54.3 (in.) 2207 (lb) Downflow Supply Length Downflow Supply Width Downflow Return Length Downflow Return Width 20.0 (in.) 28.0 (in.) 15.0 (in.) 60.5 (in.) SOUND Outdoor Sound Rating 86 (db) Project: 3000786011 LOWES #10 - TUKWILA WA Quote: 4000925551 LOWES #10 - TUKWILA WA Page 18 of 68 Last Changed: PENISTEN, JR Prepared On: 2018-06-06 Phone: 972-497-6786 Lennox Industries Inc. - Product Submittal System ID: RTU -17 Package Model: LGH156H4M Description: PKGGE/13TON/CONFIGURABLE SYSTEM FEATURES Durable Outdoor Enamel Paint Finish Scroll Compressor Pre -charged Refrigeration System Expansion Valves High Capacity Driers Auto reset high & low pressure switch with strike 3 lockout feature in Prodigy unit controller Totally Enclosed Fan Motor PVC Coated Fan Guard Fan and Limit Controls Factory Test Operated Bonded for Grounding Internal Pressure Relief Valve Overload Protection Crankcase Heater Test Timed Off Control AGA -CGA Certified Units will operate cooling down to 0 degrees F (-17.7 degrees C) without additional controls. Redundant Comb. Gas Control Valve Electronic Flame Sensor Direct Spark Ignition Separate Compressor and Controls Compartment Advanced controls with Prodigy Control System Limited compressor warranty of 5 years Limited warranty on Prodigy Unit Controller of 3 years Limited warranty on all other components of 1 year See Limited Warranty Certificate included with unit for details INCLUDED SYSTEM OPTIONS - FACTORY INSTALLED SENSIBLE ECONOMIZER/W HOOD HIGH PERF ECONOMIZER 2 IN MERV8 FILTER BLOWER PROVING SWITCH CIRCUIT BREAKER CORROSION PROTECTION MULTI -STAGE AIR VOLUME HINGED ACCESS DOORS TUBE AND FIN COIL SYSTEM MSAV BLOWER BYPASS DIRTY FILTER SWITCH GFCI - FACTORY INSTALLED/NON-POWERED BAROMETRIC RELIEF DAMPERS/W HOOD PHASE MONITOR RA SMOKE DETECTOR STANDARD CAP NOVAR ETM -2051 Project: 3000786011 LOWES #10 - TUKWILA WA Quote: 4000925551 LOWES #10 - TUKWILA WA Page 19 of 68 Last Changed: PENISTEN, JR Prepared On: 2018-06-06 Phone: 972-497-6786 Lennox Industries Inc. - Product Submittal System ID: RTU -17 • Package Model: LGH156H4M Description: PKGGE/13TON/CONFIGURABLE DIMENSIONS - INCHES (MM) CORNER WEIGHTS CENTER OF GRAVITY LGH1S6 Model No. AA BB CC DD EE FF Ibs. kg Ibs. kg Ibs. kg Ibs. kg in. mm in. mm LGH156 Std. Unit 476 224 397 187 513 242 615 290 49 1245 39-3/4 1010 LGH156 Max. Unit 588 278 477 225 540 255 665 314 48-1/4 1226 42-3/4 1086 Std. Unit - The unit with NO OPTIONS. Max. Unit -The unit with AU. OPTIONS Installed. (Economizer, etc.) 4-1/4,008) 12-3+8 • 60-1/2(1537)- T314) 15 (381) BOTTOM RETURN T AIR OPENNG fBOTTOM SUPPLY 18 7) AIR OPENNGS /1 123/8 28 (114 28 (314) (711) x(71 ) EE -4\ CENTER OF GRAVDY FF 1 (10 4 2) DI1BOTTOM POWER ENTRY 4 (102) 5 X 8 inches (127 X 203 mm) TOP VIEW 112 90-1/8 OPTIONAL OPTIONAL (27006.15) () DISCONNECT 115 VOLT OUTLET (Factory Installed) (Factory Instated Inside Unt) 54.1/4 (1378) ( i 38)6 (152) 283/4 (730) 91-1/8(2315) BASE SIDE ELERICAL END VIEW Project: 3000786011 LOWES #10 - TUKWILA WA Quote: 4000925551 LOWES #10 - TUKWILA WA Page 20 of 68 8-1/4 (210) 3114 (83) GAS SUPPLY INLET FLUE OUT LET / O 0 LIFTING Iqh HOLESpFORKLIFT SLOTS (For Fo RI9Ba99 (Front and Let Side Orly) Fr dBa• 107.314 (2737) BASE SIDE VIEW Last Changed: PENISTEN, JR Prepared On: 2018-06-06 Phone: 972-497-6786 BB CC Lennox Industries Inc. - Product Submittal System ID: RTU -17 Package Model: LGH156H4M Description: PKGGE/13TON/CONFIGURABLE ACCESSORY DIMENSIONS - INCHES (MM) OPTIONAL OUTDOOR MR HOOD DETAIL WITH STANDARD STATIC POWER EXHAUST FANS 18 (406) CoUl T At t H000 or Wax: AklAttrver 'OPTIONAL file Watt) Project: 3000786011 LOWES #10 - TUKWILA WA Quote: 4000925551 LOWES #10 - TUKWILA WA Page 21 of 68 Last Changed: PENISTEN, JR Prepared On: 2018-06-06 Phone: 972-497-6786 Lennox Industries Inc. - Product Submittal System ID: RTU -17 Package Model: LGH156H4M Description: PKGGE/13TON/CONFIGURABLE UNIT CLEARANCES - INCHES (MM) Unit With Economizer Note: 210-240-300 sizes shown r Unit Clearance A B C D Top Clearance in. mm In. mm in. mm In. mm Service Clearance 60 1524 36 914 36 934 66 1676 Unobstructed Clearance to Combustibles 36 914 1 25 1 25 1 25 Minimum Operation Clearance 45 1143 36 914 36 914 41 1041 NOTE - Ente perimeter of unit base requires a sport when elevated above the mounting surface. • Service Clearance - Required for removal of serviceable pmts. Clearance to Combustibles - Required clearance b combustible material. Minimum Operation Clearance - Required deaance for proper unit operation. Project: 3000786011 LOWES #10 - TUKWILA WA Quote: 4000925551 LOWES #10 - TUKWILA WA Page 22 of 68 Last Changed: PENISTEN, JR Prepared On: 2018-06-06 Phone: 972-497-6786 Lennox Industries Inc. - Product Submittal System ID: RTU -19,21 Package Model: LCH074H4T Description: PKGEE/6TON/CONFIGURABLE HEATING PERFORMANCE Unit Type H/E HighOutput System HeatOutput Packaged Electric/Electri 23519 (Btuh) 23519 (Btuh) Electric Heater H/E Heat Rise 7.5 (kW) 9.1 (°F) COOLING PERFORMANCE Refrigerant ARI EER ARI IEER ARI Total Power ARI GrossTotalCool ARI NetTotalCool Coil GrossTotalCool Unit NetTotalCool Coil GrossSensCool Unit NetSensCool Tube/Fin Refrigerant Charge R -410A 12.0 16.0 5700 (W) 72000 (Btuh) 69000 (Btuh) 74570 (Btuh) 71055 (Btuh) 68716 (Btuh) 65201 (Btuh) 13LBS. 11OZ Number Compressors Number of Cooling Stages Condensate Drain Size Cooling OutdoorDB Cooling MixedDB Cooling MixedWB Coil DischargeDB Coil DischargeWB Unit DischargeDB Unit DischargeWB Coil MoistureRemoval System MoistRemoval 1 2 1.00 (in.) 82.0 (°F) 80.0 (°F) 64.0 (°F) 51.9 (°F) 51.9 (°F) 53.1 (°F) 53.1 (°F) 5.5 (lb/hr) 5.5 (lb/hr) SUPPLY FAN PERFORMANCE Supply AirFlow ExtStaticPress Supply SupplyFan Req'dPower SupplyFan NomPower Supply Fan Type SupplyDriveReq'd RPM SupplyDrive Min RPM SupplyDrive Max RPM 2400 (cfm) 0.40 (in.WC) 1.12 (hp) 2.00 (hp) MSAV Belt Drive 777 (rpm) 632 (rpm) 875 (rpm) TotalStaticPress Wet Coil Static Press Electric H/E Static Press Added Filter Static Press Economizer Static Press Air Filter Qty Air Filter Length Air Filter Width Air Filter Thickness 0.83 (in.WC) 0.13 (in.WC) 0.20 (in.WC) 0.05 (in.WC) 0.05 (in.WC) 4 20.0 (in.) 20.0 (in.) 2.0 (in.) ELECTRICAL Voltage Frequency System MCA System MOCP Compressors RLA Cooling FLA Total Unit Oper Range -Nom Voltage 460V 3Ph 60 (Hz) 16.0 (amp) 20 (amp) 8.5 (amp) 11.9 (amp) +/- 10% SupplyFan FLA CondensingUnit FLA CondenserFan Power 2.1 (amp) 1.3 (amp) 375 (W) DIMENSIONS Cabinet Width Cabinet Length Cabinet Height Total Weight 47.0 (in.) 85.3 (in.) 46.9 (in.) 162 (lb) Downflow Supply Length Downflow Supply Width Downflow Return Length Downflow Return Width 20.0 (in.) 18.0 (in.) 29.0 (in.) 11.0 (in.) SOUND Outdoor Sound Rating 82 (db) Project: 3000786011 LOWES #10 - TUKWILA WA Quote: 4000925551 LOWES #10 - TUKWILA WA Page 23 of 68 Last Changed: PENISTEN, JR Prepared On: 2018-06-06 Phone: 972-497-6786 Lennox Industries Inc. - Product Submittal System ID: RTU -19,21 Package Model: LCH074H4T Description: PKGEE/6TON/CONFIGURABLE SYSTEM FEATURES Durable Outdoor Enamel Paint Finish Scroll Compressor Pre -charged Refrigeration System Expansion Valves High Capacity Driers Auto reset high & low pressure switch with strike 3 lockout feature in Prodigy unit controller Totally Enclosed Fan Motor PVC Coated Fan Guard Fan and Limit Controls Factory Test Operated Bonded for Grounding Internal Pressure Relief Valve Overload Protection Crankcase Heater Test Timed Off Control Units will operate cooling down to 0 degrees F (-17.7 degrees C) without additional controls. Separate Compressor and Controls Compartment Advanced controls with Prodigy Control System Limited compressor warranty of 5 years Limited warranty on Prodigy Unit Controller of 3 years Limited warranty on all other components of 1 year See Limited Warranty Certificate included with unit for details INCLUDED SYSTEM OPTIONS - FACTORY INSTALLED ELECTRIC HEAT SENSIBLE ECONOMIZER/W HOOD HIGH PERF ECONOMIZER 2 IN MERV8 FILTER BLOWER PROVING SWITCH CIRCUIT BREAKER CORROSION PROTECTION MULTI -STAGE AIR VOLUME HINGED ACCESS DOORS TUBE AND FIN COIL SYSTEM DIRTY FILTER SWITCH GFCI - FACTORY INSTALLED/NON-POWERED BAROMETRIC RELIEF DAMPERS/W HOOD PHASE MONITOR RA SMOKE DETECTOR STANDARD CAP NOVAR ETM -2051 Project: 3000786011 LOWES #10 - TUKWILA WA Quote: 4000925551 LOWES #10 - TUKWILA WA Page 24 of 68 Last Changed: PENISTEN, JR Prepared On: 2018-06-06 Phone: 972-497-6786 Lennox Industries Inc. - Product Submittal System ID: RTU -19,21 Package Model: LCH074H4T Description: PKGEE/6TON/CONFIGURABLE DIMENSIONS - INCHES (MM) CORNER WEIGHTS CENTER OF GRAVITY Model No. AA BB CC OD EE FF Ibs. kg lbs. kg Ibs. kg tbs. kg in. mm in. mm LCH036 Base Unit 92 42 112 51 180 82 148 67 38.5 978 18 457 LC/1036 Mme. Unit 133 61 151 69 243 110 215 98 40 1016 18 457 LCH048 Base Units 97 44 118 54 190 87 157 71 38.5 979 18 457 LC11048 Max. Unit 139 63 158 72 254 115 224 102 40 1016 18 457 LCH060 Base Unit 112 51 138 62 219 100 181 82 38.5 978 18 457 LCH060 Max. Unit 159 72 180 82 290 132 257 117 40 1016 18 457 LC11072 Base Uiit 126 57 152 69 246 112 202 92 38.5 978 18 457 LCH072 Max. Unit 168 76 190 86 308 139 270 123 40 1016 18 457 LCH074 Base Unit 126 57 152 69 246 112 202 92 38-5 978 18 457 LCH074 tau UM 168 76 190 88 306 139 270 123 40 1016 18 457 BassUnt-IleWholly NORITE ilPL0Pn0A6. Mac. flit -lbw is* rah All DIDERNpLMOMS SWAM SNOW SUB: Pam Blond Fans, CoNtoE.>da). Does sat fedudeaxessairsedsn l bnit arl staepoeiroast* -y I it. too r-1 r—Lool�r car END VIEW Project: 3000786011 LOWES #10 - TUKWILA WA Quote: 4000925551 LOWES #10 - TUKWILA WA Page 25 of 68 LIMO Far tEBIEE mm utlalaT ,st cumi 14vP VIBV pan) SIDE VIEW 1 F FOZICLOT CLOTS I CCZYON AL b V2 HOZSZBITAl' 6,2 Kiat LSA int t. .Y A71 0401 iErIL1N An 044 Mara[rd) OPGXNG 021:143G BACK VIEW""I ��� Last Changed: PENISTEN, JR Prepared On: 2018-06-06 Phone: 972-497-6786 a ipan • 6) r•I • •I•] mg len) 16414 MVO a16& SIDE VIEW 1 F FOZICLOT CLOTS I CCZYON AL b V2 HOZSZBITAl' 6,2 Kiat LSA int t. .Y A71 0401 iErIL1N An 044 Mara[rd) OPGXNG 021:143G BACK VIEW""I ��� Last Changed: PENISTEN, JR Prepared On: 2018-06-06 Phone: 972-497-6786 Lennox Industries Inc. - Product Submittal System ID: RTU -19,21 Package Model: LCH074H4T Description: PKGEE/6TON/CONFIGURABLE ACCESSORY DIMENSIONS - INCHES (MM) OUTDOOR AIR HOOD DETAIL FOR OPTIONAL ECONOMIZER AND BAROMETRIC RELIEF DAMPERS (Down -Flow Applications) OP110NAL OUTDOOR AIR HOOD (Fum shed with Eoonmmizen 113'4 2.78; 036 nea 0A8 15.3+L (/6A; 060 dm 072 OPTIONAL BAROMETRIC RELIEF HCOD (FtamkhW with ECO TUS) OUTDOOR AIR HOOD FOR ECONOMIZER (Furnishod) SIDE VIEW BAROMETRIC RELIEF HOOD FOR ECONOMIZER (Furnished) Model A B C No. in. mm in. mm in. mm 036.048 19-1/4 489 13 330 11-3/4 298 060.072 23-1/4 591 17 432 15-3/4 400 Project: 3000786011 LOWES #10 - TUKWILA WA Quote: 4000925551 LOWES #10 - TUKWILA WA Page 26 of 68 Last Changed: PENISTEN, JR Prepared On: 2018-06-06 Phone: 972-497-6786 Lennox Industries Inc. - Product Submittal • System ID: RTU -19,21 Package Model: LCH074H4T Description: PKGEE/6TON/CONFIGURABLE UNIT CLEARANCES - INCHES (MM) 1 l OUTDOOR AR HOOD —D� B "l ' Unit Clearance A B CD Top Clearance in. mm in. mm in. mm in. mm Service Clearance 36 914 36 914 36 934 36 914 Unobstructed Minimum Operation Clearance 36 914 36 914 36 914 38 914 NOTE - Entire perimeter of unit base requires support when elevated above the mounting surface. ' Service Clearance - Rewired for removal or saviceable pats. Minimus Operation Clearance - Required clearance for proper wit operation. Project: 3000786011 LOWES #10 - TUKWILA WA Quote: 4000925551 LOWES #10 - TUKWILA WA Page 27 of 68 Last Changed: PENISTEN, JR Prepared On: 2018-06-06 Phone: 972-497-6786 Lennox Industries Inc. - Product Submittal System ID: RTU -20 Package Model: LCH120H4M Description: PKGEE/10TON/CONFIGURABLE HEATING PERFORMANCE Unit Type H/E HighOutput System HeatOutput Packaged Electric/Electri 47037 (Btuh) 47037 (Btuh) Electric Heater H/E Heat Rise 15.0 (kW) 10.9 (°F) COOLING PERFORMANCE Refrigerant ARI EER ARI IEER ARI Total Power ARI GrossTotalCool ARI NetTotalCool Coil GrossTotalCool Unit NetTotalCool Coil GrossSensCool Unit NetSensCool Tube/Fin Refrigerant Charge R -410A 12.2 14.0 9800 (W) 122000 (Btuh) 118000 (Btuh) 126998 (Btuh) 121196 (Btuh) 110710 (Btuh) 104908 (Btuh) 28 LBS. 0 OZ. Number Compressors Number of Cooling Stages Condensate Drain Size Cooling OutdoorDB Cooling MixedDB Cooling MixedWB Coil DischargeDB Coil DischargeWB Unit DischargeDB Unit DischargeWB Coil MoistureRemoval System MoistRemoval 2 2 1.00 (in.) 82.0 (°F) 80.0 (°F) 64.0 (°F) 52.8 (°F) 52.6 (°F) 54.0 (°F) 53.1 (°F) 15.4 (lb/hr) 15.4 (lb/hr) SUPPLY FAN PERFORMANCE Supply AirFlow ExtStaticPress Supply SupplyFan Req'dPower SupplyFan NomPower Supply Fan Type SupplyDriveReq'd RPM SupplyDrive Min RPM SupplyDrive Max RPM 4000 (cfm) 0.40 (in.WC) 1.94 (hp) 3.00 (hp) MSAV Belt Drive 854 (rpm) 730 (rpm) 970 (rpm) TotalStaticPress Wet Coil Static Press Electric H/E Static Press Added Filter Static Press Economizer Static Press Air Filter Qty Air Filter Length Air Filter Width Air Filter Thickness 0.87 (in.WC) 0.15 (in.WC) 0.09 (in.WC) 0.04 (in.WC) 0.19 (in.WC) 4 20.0 (in.) 25.0 (in.) 2.0 (in.) ELECTRICAL Voltage Frequency System MCA System MOCP Compressors RLA Cooling FLA Total Unit Oper Range -Nom Voltage 460V 3Ph 60 (Hz) 29.0 (amp) 30 (amp) 16.0 (amp) 23.4 (amp) +/- 10% SupplyFan FLA CondensingUnit FLA CondenserFan Power 4.8 (amp) 2.6 (amp) 800 (W) DIMENSIONS Cabinet Width Cabinet Length Cabinet Height Total Weight 60.1 (in.) 101.3 (in.) 46.9 (in.) 164 (lb) Downflow Supply Length Downflow Supply Width Downflow Retum Length Downflow Return Width 20.0 (in.) 28.0 (in.) 24.0 (in.) 27.0 (in.) SOUND Outdoor Sound Rating 88 (db) Project: 3000786011 LOWES #10 - TUKWILA WA Quote: 4000925551 LOWES #10 • TUKWILA WA Page 28 of 68 Last Changed: PENISTEN, JR Prepared On: 2018-06-06 Phone: 972-497-6786 Lennox Industries Inc. - Product Submittal System ID: RTU -20 Package Model: LCH120H4M Description: PKGEE/10TON/CONFIGURABLE SYSTEM FEATURES Durable Outdoor Enamel Paint Finish Scroll Compressor Pre -charged Refrigeration System Expansion Valves High Capacity Driers Auto reset high & low pressure switch with strike 3 lockout feature in Prodigy unit controller Totally Enclosed Fan Motor PVC Coated Fan Guard Fan and Limit Controls Factory Test Operated Bonded for Grounding Internal Pressure Relief Valve Overload Protection Crankcase Heater Test Timed Off Control Units will operate cooling down to 0 degrees F (-17.7 degrees C) without additional controls. Separate Compressor and Controls Compartment Advanced controls with Prodigy Control System Limited compressor warranty of 5 years Limited warranty on Prodigy Unit Controller of 3 years Limited warranty on all other components of 1 year See Limited Warranty Certificate included with unit for details INCLUDED SYSTEM OPTIONS - FACTORY INSTALLED ELECTRIC HEAT SENSIBLE ECONOMIZER/W HOOD HIGH PERF ECONOMIZER 2 IN MERV8 FILTER BLOWER PROVING SWITCH CIRCUIT BREAKER CORROSION PROTECTION MULTI -STAGE AIR VOLUME HINGED ACCESS DOORS TUBE AND FIN COIL SYSTEM MSAV BLOWER BYPASS DIRTY FILTER SWITCH GFCI - FACTORY INSTALLED/NON-POWERED BAROMETRIC RELIEF DAMPERS/W HOOD PHASE MONITOR RA SMOKE DETECTOR STANDARD CAP NOVAR ETM -2051 Project: 3000786011 LOWES #10 - TUKWILA WA Quote: 4000925551 LOWES #10 - TUKWILA WA Page 29 of 68 Last Changed: PENISTEN, JR Prepared On: 2018-06-06 Phone: 972-497-6786 Lennox Industries Inc. - Product Submittal System ID: RTU -20 Package Model: LCH120H4M Description: PKGEE/1OTON/CONFIGURABLE DIMENSIONS - INCHES (MM) Model No. CORNER WEIGHTS CENTER OF GRAVITY AA BB CC DD EE FF Baso Max. Base Max. Bass Max. Baso Max. Baso Max. Bass Max. lbs. kg lbs. kg lbs. kg lbs. kg tbs. kg Ibs. kg lbs. kg lbs. kg In. mm In. mm In. mm In. nvn 092 281 127 327 148 252 114 286 130 275 126 306 139 312 142 358 162 48.5 1181 45.6 1156 24.6 822 25.5 648 102 282 128 329 149 254 115 287 130 276 125 308 139 314 143 360 163 46.5 1181 45.5 1156 24.5 822 25.5 648 120 294 133 340 154 264 120 297 135 283 128 318 144 321 146 372 169 484 1181 45.5 1156 24.5 622 25.5 648 150 304 138 350 159 273 124 306 139 293 133 327 148 332 151 383 174 464 1181 45.6 1156 24.5 822 25.5 648 Bees udt- Ths unit OM NO INTERNAL OPTIONS_ Max OM • The lot %WM ALL NTERIN1OPT)ON3 asmsed. (E xmcmizer, Sterdasd Mato PowerEstieust Fns cantos, eta). Ooea notMaude *commies camel* unt or MDh state pave admit PUN (1StT( END VIEW 3412 R1) Project: 3000786011 LOW ES #10 - TUKWILA WA Quote: 4000925551 LOWES #10 - TUKWILA WA Page 30 of 68 5-1A AA ED IA (tW) SOTTOIA Si19a 00001PENTRr 0411140) OIL 425) BECTNO WETS ff11�3!r 6OTTONSUPPLY 01 ( AROVENNO p. _ WWI iKT OtW 114) d01ms= Moo� 10144 MASK PDX torvllt SIDE VIEW IO TN. WPPt.YAR M)R1 TN. 1510 OP01N0 PETUTN AR ( ) OPEN/NO 12) 12-115 IM ool (156) �s,aa ODM E NSATE DAMN (SACK) (137) BIDE VIEW (Horizontal Openings) Last Changed: PENISTEN, JR Prepared On: 2018-06-06 Phone: 972-497-6786 001100101412 POOIM1N 1 OM .:•—_ __.__.-10=MMK...I FORKIHR 100T5 1DE3)UFTP10110103 101414 grat MAW) (7!5711 SIDE VIEW IO TN. WPPt.YAR M)R1 TN. 1510 OP01N0 PETUTN AR ( ) OPEN/NO 12) 12-115 IM ool (156) �s,aa ODM E NSATE DAMN (SACK) (137) BIDE VIEW (Horizontal Openings) Last Changed: PENISTEN, JR Prepared On: 2018-06-06 Phone: 972-497-6786 Lennox Industries Inc. - Product Submittal System ID: RTU -20 Package Model: LCH120H4M Description: PKGEE/10TON/CONFIGURABLE ACCESSORY DIMENSIONS - INCHES (MM) OUTDOOR AIR HOOD DETAIL OUTDOOR NR HOOD (Furnished with Economizer or Outdoor Nr Damper) EXHAUST NR HOOD (Furnished, Field Installed) Project: 3000786011 LOWES #10 - TUKWILA WA Quote: 4000925551 LOWES #10 - TUKWILA WA Page 31 of 68 Last Changed: PENISTEN, JR Prepared On: 2018-06-06 Phone: 972-497-6786 Lennox Industries Inc. - Product Submittal System ID: RTU -20 Package Model: LCH120H4M Description: PKGEE/10TON/CONFIGURABLE ELECTRIC HEAT CAPACITIES UNIT CLEARANCES - INCHES (MM) OPTIMAL elr►000R AR H000 r z ' Unit Clearance 7.5 kW 15 kW 22.5 kW 30 kW 45 kW 60 kW Volts input kW Input 8tuh Output No. of Stages kW Input Btuh Output No. of Stages kW Input Btuh Output No. of Stages kW Input Btuh Output No. of Stages kW Input Btuh Output No. of Stages kW Input Btuh Output No. of Stages 208 5.6 19,100 1 11.3 38,600 1 16.9 57,700 2 22.5 76,800 2 33.8 115,300 2 45.0 153,600 2 220 6.3 21,500 1 12.6 43,000 1 18.9 64,500 2 25.2 86,000 2 37.8 129,000 2 50.4 172,000 2 230 6.9 23,600 1 13.8 47,100 1 20.7 70,700 2 27.5 93,900 2 41.3 141,000 2 55.1 188,000 2 240 7.5 25,600 1 15.0 51,200 1 22.5 76,800 2 30.0 102,400 2 45.0 153,600 2 60.0 204,800 2 440 6.9 21,500 1 12.6 43,000 1 18.9 64,500 2 252 86.000 2 37.8 129.000 2 50.4 172.000 2 460 6.9 23,600 1 13.8 47,100 1 20.7 70,700 2 27.5 93,900 2 41.3 141,000 2 55.1 188,000 2 480 7.5 25,600 1 15.0 51,200 1 22.5 76,800 2 30.0 102,400 2 45.0 153,600 2 60.0 204,800 2 550 6.3 21,500 1 12.6 43,000 1 18.9 64,500 2 252 86,000 2 37.8 129,000 2 50.4 172,000 2 575 6.9 23,600 1 13.8 47.100 1 20.7 70,700 2 27.5 93,900 2 41.3 141,000 2 55.1 188.000 2 600 7.5 25,600 1 15.0 51,200 1 22.5 76,800 2 30.0 102,400 2 45.0 153,600 2 60.0 204,800 2 UNIT CLEARANCES - INCHES (MM) OPTIMAL elr►000R AR H000 r z ' Unit Clearance A B C D Top Clearance in. mm in. mm in. mm in. mm Service Clearance 60 1524 36 914 36 934 60 1524 Unobstructed Minimum Operation Clearance 36 914 36 914 36 914 36 914 NOTE - Entire perimeter of unit base requires support when elevated above the mounting surface. r Service Clearance - Required for removal of serviceable: parts. Mlnimurn Operation Clearance - Required clearance for proper unit operation. Project: 3000786011 LOWES #10 - TUKWILA WA Quote: 4000925551 LOWES #10 - TUKWILA WA Page 32 of 68 Last Changed: PENISTEN, JR Prepared On: 2018-06-06 Phone: 972-497-6786 Lennox Industries Inc. - Product Submittal System ID: RTU -9 Package Model: LGH036H4E Description: PKGGE/3TON/CONFIGURABLE HEATING PERFORMANCE Unit Type H/E HighInput H/E HighOutput System HeatOutput Packaged Gas Electric 65000 (Btuh) 52000 (Btuh) 52000 (Btuh) Gas Supply Connection H/E Heat Rise AFUE/ ThermalEff Number of Heating Stages Gas Supply Pressure 0.50 (in.) 40.1 (°F) 80 1 7 (in.WC) COOLING PERFORMANCE Refrigerant ARI EER ARI SEER ARI Total Power ARI GrossTotalCool ARI NetTotalCool Coil GrossTotalCool Unit NetTotalCool Coil GrossSensCool Unit NetSensCool Tube/Fin Humiditrol Refrigerant Charge R -410A 12.5 17.0 2800 (W) 36600 (Btuh) 36000 (Btuh) 36670 (Btuh) 35478 (Btuh) 32600 (Btuh) 31408 (Btuh) 9 LBS. 12 0Z. Number Compressors Number of Cooling Stages Condensate Drain Size Cooling OutdoorDB Cooling MixedDB Cooling MixedWB Coil DischargeDB Coil DischargeWB Unit DischargeDB Unit DischargeWB Coil MoistureRemoval System MoistRemoval 1 2 1.00 (in.) 82.0 (°F) 80.0 (°F) 64.0 (°F) 53.3 (°F) 53.1 (°F) 54.3 (°F) 53.5 (°F) 3.8 (lb/hr) 3.8 (lb/hr) SUPPLY FAN PERFORMANCE Supply AirFlow ExtStaticPress Supply SupplyFan Req'dPower SupplyFan NomPower Supply Fan Type SupplyDriveReq'd RPM Motor Torque Pct 1200 (cfm) 0.40 (in.WC) 0.50 (hp) 0.50 (hp) MSAV Direct Drive 879 (rpm) 58 TotalStaticPress Wet Coil Static Press Added Filter Static Press Humiditrol Static Press Economizer Static Press Air Filter Qty Air Filter Length Air Filter Width Air Filter Thickness 0.54 (in.WC) 0.05 (in.WC) 0.04 (in.WC) 0.01 (in.WC) 0.04 (in.WC) 4 16.0 (in.) 20.0 (in.) 2.0 (in.) ELECTRICAL Voltage Frequency System MCA System MOCP Compressors RLA Cooling FLA Total Unit Oper Range -Nom Voltage 460V 3Ph 60 (Hz) 12.0 (amp) 15 (amp) 4.5 (amp) 8.8 (amp) +/- 10% SupplyFan FLA CondensingUnit FLA 2.2 (amp) 2.1 (amp) DIMENSIONS Cabinet Width Cabinet Length Cabinet Height Total Weight 47.0 (in.) 85.3 (in.) 38.9 (in.) 158 (lb) Downflow Supply Length Downflow Supply Width Downflow Return Length Downflow Return Width 20.0 (in.) 18.0 (in.) 29.0 (in.) 11.0 (in.) SOUND Outdoor Sound Rating 75 (db) Project: 3000786011 LOWES #10 - TUKWILA WA Quote: 4000925551 LOWES #10 - TUKWILA WA Page 33 of 68 Last Changed: PENISTEN, JR Prepared On: 2018-06-06 Phone: 972-497-6786 Lennox Industries Inc. - Product Submittal System ID: RTU -9 Package Model: LGH036H4E Description: PKGGE/3TON/CONFIGURABLE SYSTEM FEATURES Durable Outdoor Enamel Paint Finish Scroll Compressor Pre -charged Refrigeration System Expansion Valves High Capacity Driers Auto reset high & low pressure switch with strike 3 lockout feature in Prodigy unit controller Totally Enclosed Fan Motor PVC Coated Fan Guard Fan and Limit Controls Factory Test Operated Bonded for Grounding Internal Pressure Relief Valve Overload Protection Crankcase Heater Test Timed Off Control AGA -CGA Certified Units will operate cooling down to 0 degrees F (-17.7 degrees C) without additional controls. Redundant Comb. Gas Control Valve Electronic Flame Sensor Direct Spark Ignition Separate Compressor and Controls Compartment Advanced controls with Prodigy Control System Limited compressor warranty of 5 years Limited warranty on Prodigy Unit Controller of 3 years Limited warranty on all other components of 1 year See Limited Warranty Certificate included with unit for details INCLUDED SYSTEM OPTIONS - FACTORY INSTALLED SENSIBLE ECONOMIZER/W HOOD HIGH PERF ECONOMIZER 2 IN MERV8 FILTER BLOWER PROVING SWITCH CIRCUIT BREAKER CORROSION PROTECTION MULTI -STAGE AIR VOLUME HINGED ACCESS DOORS TUBE AND FIN COIL SYSTEM DIRTY FILTER SWITCH GFCI - FACTORY INSTALLED/NON-POWERED BAROMETRIC RELIEF DAMPERS/W HOOD HUMIDITROL PHASE MONITOR RA SMOKE DETECTOR STANDARD CAP NOVAR ETM -2051 INCLUDED SYSTEM OPTIONS - FIELD INSTALLED 21 W06 1 A335MT13AE1- SNSR, TEMP RH Project: 3000786011 LOWES #10 - TUKWILA WA Quote: 4000925551 LOWES #10 - TUKWILA WA Page 34 of 68 Last Changed: PENISTEN, JR Prepared On: 2018-06-06 Phone: 972-497-6786 Lennox Industries Inc. - Product Submittal System ID: RTU -9 Package Model: LGH036H4E Description: PKGGE/3TON/CONFIGURABLE DIMENSIONS - INCHES (MM) CORNER WEIGHTS CENTER OF GRAVITY Model No. AA BB CC DO EE FF tbs. kg lbs. kg tbs. kg tbs. kg In. ren M. mm LGH036 Bass Unit 98 45 119 54 192 87 158 72 38.5 978 18 457 LGH036 Max. Unit 137 62 155 70 250 113 221 100 40 1016 18 457 LGM048 Base Unit 104 47 126 57 202 92 167 76 38.5 978 18 457 LGH048 Max.Unit 145 66 164 74 264 120 233 106 40 1016 18 457 LGH060 Base Unit 118 54 144 65 232 105 191 87 38.5 978 18 457 LGH060 Max. Unit 164 75 186 84 299 136 264 120 40 1016 18 457 LGH072 Base Unit 132 60 160 73 258 117 212 96 38.5 978 18 457 LGH072 Max_ Unit 173 78 195 89 314 143 278 126 40 1016 18 457 LGH074 Base Unit 132 60 160 73 258 117 212 96 38.5 978 18 457 LGH074 Max. lkg 173 78 195 89 314 143 278 126 40 1016 18 457 !lose Oil -lb*wit wet NO*BER . OPTIONS. Ms.*k*-7besr* wibALLmonk ornateWiled. (Eooaaaiw:Stat d Stalk PaavrEchatst Fsa.Oomols, )L Dots not lroxitaccoa edemil to mice higAsolo power admit. MOM MN MK* END MEW 1 rss Mr *WV Energetics.' Packaged Gas / Electric 3 to 6 Ton I Page 52 Project: 3000786011 LOWES #10 - TUKWILA WA Quote: 4000925551 LOWES #10 - TUKWILA WA Page 35 of 68 IMMO atoms co*Sourasaung ,#xsi is TopVftw,- SIDE VIEW ,P FOA9Q.FT CLOTS HORRZONIAL MORIZOIT L PCaSUPPLY AEI FETILVI Jeg derEnajdMOMS (*b) OPO= IVa) (Mr %oul rmaornsa) BACK VIEW Last Changed: PENISTEN, JR Prepared On: 2018-06-06 Phone: 972-497-6786 MIMI (2114 CCINDIMILCIE ts"Q cis i a arra �''a°' 0a p doj s 20.ta t 4.11......._ (�f 6sv654,4(21t6) 02157-4.1 i SIDE VIEW ,P FOA9Q.FT CLOTS HORRZONIAL MORIZOIT L PCaSUPPLY AEI FETILVI Jeg derEnajdMOMS (*b) OPO= IVa) (Mr %oul rmaornsa) BACK VIEW Last Changed: PENISTEN, JR Prepared On: 2018-06-06 Phone: 972-497-6786 Lennox Industries Inc. - Product Submittal System ID: RTU -9 • Package Model: LGH036H4E Description: PKGGE/3TON/CONFIGURABLE ACCESSORY DIMENSIONS - INCHES (MM) OUTDOOR AIR HOOD DETAIL FOR OPTIONAL ECONOMIZER AND BAROMETRIC RELIEF DAMPERS (Down -Flow Applications) cer ONAL OUTDOOR AIR FOOD (Fumehe0 mth Erororrizerl 113'4 t2O3; 036 el ru 0!6 15•:VI i1i:010601Mu 012 OPTONAL BAROMETRIC REUEFHCOO (Fumther, NOM &ororrizr) OUTDOOR AIR HOOD FOR ECONOMIZER (Fumishod) SIDE VIEW BAROMETRIC RELIEF HOOD FOR ECONOMIZER (Furnished) Model A B C No. in. mm in. nen M. mm 038.048 19-1/4 489 13 330 11-3/4 298 060, 072 23-1/4 591 17 432 15.314 400 Project: 3000786011 LOWES #10 - TUKWILA WA Quote: 4000925551 LOWES #10 - TUKWILA WA Page 36 of 68 Last Changed: PENISTEN, JR Prepared On: 2018-06-06 Phone: 972-497-6786 Lennox Industries Inc. - Product Submittal System ID: RTU -9 Package Model: LGH036H4E Description: PKGGE/3TON/CONFIGURABLE UNIT CLEARANCES - INCHES (MM) OUTDOOR AIR HOOD D B 1 r Unit Clearance A B C D Top Clearance in. mm in. mm in. mm in. mm Service Clearance 48 1219 36 914 36 934 36 914 Unobstructed Clearance to Combustibles 36 914 1 25 1 25 1 25 Minimum Operation Clearance 36 914 36 914 36 914 36 914 NOTE - Entire perimeter d unit base requires support when elevated above the naming surface. ' Service Clearance - Required ler removal at serviceable pans. Clearance to Combustibles - Required clearance to combustible material. MInimum Operation Clearance - Required clearance ler proper unit operation. Project: 3000786011 LOWES #10 - TUKWILA WA Quote: 4000925551 LOWES #10 - TUKWILA WA Page 37 of 68 Last Changed: PENISTEN, JR Prepared On: 2018-06-06 Phone: 972-497-6786 Lennox Industries Inc. - Product Submittal System ID: RTU -10 Package Model: LCH060H4E Description: PKGEE/5TON/CONFIGURABLE HEATING PERFORMANCE Unit Type H/E HighOutput System HeatOutput Packaged Electric/Electri 47037 (Btuh) 47037 (Btuh) Electric Heater H/E Heat Rise 15.0 (kW) 21.8 (°F) COOLING PERFORMANCE Refrigerant ARI EER ARI SEER ARI Total Power ARI GrossTotalCool ARI NetTotalCool Coil GrossTotalCool Unit NetTotalCool Coil GrossSensCool Unit NetSensCool Tube/Fin Humiditrol Refrigerant Charge R -410A 12.7 17.0 4700 (W) 61600 (Btuh) 60000 (Btuh) 64348 (Btuh) 61964 (Btuh) 56449 (Btuh) 54066 (Btuh) 16 LBS. 0 OZ. Number Compressors Number of Cooling Stages Condensate Drain Size Cooling OutdoorDB Cooling MixedDB Cooling MixedWB Coil DischargeDB Coil DischargeWB Unit DischargeDB Unit DischargeWB Coil MoistureRemoval System MoistRemoval 1 2 1.00 (in.) 82.0 (°F) 80.0 (°F) 64.0 (°F) 52.3 (°F) 52.3 (°F) 53.4 (°F) 52.9 (°F) 7.4 (lb/hr) 7.4 (lb/hr) SUPPLY FAN PERFORMANCE Supply AirFlow ExtStaticPress Supply SupplyFan Req'dPower SupplyFan NomPower Supply Fan Type SupplyDriveReq'd RPM Motor Torque Pct 2000 (cfm) 0.40 (in.WC) 1.00 (hp) 1.00 (hp) MSAV Direct Drive 1023 (rpm) 74 TotalStaticPress Wet Coil Static Press Electric H/E Static Press Added Filter Static Press Humiditrol Static Press Economizer Static Press Air Filter Qty Air Filter Length Air Filter Width Air Filter Thickness 0.78 (in.WC) 0.10 (in.WC) 0.15 (in.WC) 0.05 (in.WC) 0.03 (in.WC) 0.05 (in.WC) 4 20.0 (in.) 20.0 (in.) 2.0 (in.) ELECTRICAL Voltage Frequency System MCA System MOCP Compressors RLA Cooling FLA Total Unit Oper Range -Nom Voltage 460V 3Ph 60 (Hz) 28.0 (amp) 30 (amp) 7.2 (amp) 13.0 (amp) +/- 10% SupplyFan FLA CondensingUnit FLA CondenserFan Power 3.7 (amp) 2.1 (amp) 350 (W) DIMENSIONS Cabinet Width Cabinet Length Cabinet Height Total Weight 47.0 (in.) 85.3 (in.) 46.9 (in.) 192 (lb) Downflow Supply Length Downflow Supply Width Downflow Return Length Downflow Return Width 20.0 (in.) 18.0 (in.) 29.0 (in.) 11.0 (in.) SOUND Outdoor Sound Rating 82 (db) Project: 3000786011 LOWES #10 - TUKWILA WA Quote: 4000925551 LOWES #10 - TUKWILA WA Page 38 of 68 Last Changed: PENISTEN, JR Prepared On: 2018-06-06 Phone: 972-497-6786 • Lennox Industries Inc. - Product Submittal System ID: RTU -10 Package Model: LCH060H4E Description: PKGEE/5TON/CONFIGURABLE SYSTEM FEATURES Durable Outdoor Enamel Paint Finish Scroll Compressor Pre -charged Refrigeration System Expansion Valves High Capacity Driers Auto reset high & low pressure switch with strike 3 lockout feature in Prodigy unit controller Totally Enclosed Fan Motor PVC Coated Fan Guard Fan and Limit Controls Factory Test Operated Bonded for Grounding Internal Pressure Relief Valve Overload Protection Crankcase Heater Test Timed Off Control Units will operate cooling down to 0 degrees F (-17.7 degrees C) without additional controls. Separate Compressor and Controls Compartment Advanced controls with Prodigy Control System Limited compressor warranty of 5 years Limited warranty on Prodigy Unit Controller of 3 years Limited warranty on all other components of 1 year See Limited Warranty Certificate included with unit for details INCLUDED SYSTEM OPTIONS - FACTORY INSTALLED ELECTRIC HEAT SENSIBLE ECONOMIZER/W HOOD HIGH PERF ECONOMIZER 2 IN MERV8 FILTER BLOWER PROVING SWITCH CIRCUIT BREAKER CORROSION PROTECTION MULTI -STAGE AIR VOLUME HINGED ACCESS DOORS TUBE AND FIN COIL SYSTEM DIRTY FILTER SWITCH GFCI - FACTORY INSTALLED/NON-POWERED BAROMETRIC RELIEF DAMPERS/W HOOD HUMIDITROL PHASE MONITOR RA SMOKE DETECTOR STANDARD CAP NOVAR ETM -2051 INCLUDED SYSTEM OPTIONS - FIELD INSTALLED 21 W06 1 A335MT13AE1- SNSR, TEMP RH Project: 3000786011 LOWES #10 - TUKWILA WA Quote: 4000925551 LOWES #10 - TUKWILA WA Page 39 of 68 Last Changed: PENISTEN, JR Prepared On: 2018-06-06 Phone: 972-497-6786 Lennox Industries Inc. - Product Submittal System ID: RTU -10 Package Model: LCH060H4E Description: PKGEE/5TON/CONFIGURABLE DIMENSIONS - INCHES (MM) CORNER WEIGHTS CENTER OF GRAVITY Model No. AA BB CC DD EE FF lbs. kg Ors. k0 lbs. k0 tbs. kp in. mm In. mm 101036 Base Unit 92 42 112 51 180 82 148 67 38.5 978 18 457 LCH036 Max. Unit 133 61 151 69 243 110 215 98 40 1016 18 457 LCH048 Base Unit 97 44 118 54 190 87 157 71 38..5 978 18 457 LCHO48 Max. Unit 139 63 158 72 254 115 224 102 40 1016 18 457 LCH060 Base Unk 112 51 138 62 219 100 181 82 38.5 978 18 457 LCHD60 Mac Unit 159 72 180 82 290 132 257 117 40 1016 18 457 LCH072 Base Unit 126 57 152 69 246 112 202 92 38,5 978 18 457 LCH072 Max. Uric 168 78 190 86 306 139 270 123 40 1016 18 457 LCH074 Base Unit 126 57 1S2 69 248 112 202 92 38.5 978 18 457 LCH074 Max Unft 168 76 190 86 306 139 270 123 40 1016 18 457 Baia Unit -1trtwit ugh NlO ailmirti.moms, lastthe -The animal All=mom OPTIONS tsslatid &WadSta3ePaw Wait Fans.Oar**.ehiDesestbdudeamosoriasadmit logger 10 dilkporareshaal 111.1104,1641111111 0 0 00 I-- "a ---I END VIBAI Project: 3000786011 LOWES #10 -TUKWILA WA Quote: 4000925551 LOWES #10 -TUKWILA WA Page 40 of 68 INTIM 1 1 rt�rtmt llptnoaoe� resew alKOIMal sp'sxapsxatda vpVEW pia) SIDE VIEW 05) FOS# 1L O$ MOXI T.4L w HORGTI DU. Ezra tad) CiPtIOIG OKAING BACK VIEW'°' Last Changed: PENISTEN, JR Prepared On: 2018-06-06 Phone: 972-497-6786 E. ppm)111 1 E .I '1- - .I.l 9 L�1 EWA M) RAM SIDE VIEW 05) FOS# 1L O$ MOXI T.4L w HORGTI DU. Ezra tad) CiPtIOIG OKAING BACK VIEW'°' Last Changed: PENISTEN, JR Prepared On: 2018-06-06 Phone: 972-497-6786 Lennox Industries Inc. - Product Submittal System ID: RTU -10 Package Model: LCH060H4E Description: PKGEE/5TON/CONFIGURABLE ACCESSORY DIMENSIONS - INCHES (MM) OUTDOOR AIR HOOD DETAIL FOR OPTIONAL ECONOMIZER AND BAROMETRIC RELIEF DAMPERS (Down -Flow Applications) OPTIONAL OUTDOOR NR HOOD (FYNml1E0 ANA Emromierl OPTIONAL BAROMETRI REUEFHCOO IFumkMd u1tl1 Ecommi=r) OUTDOOR AIR HOOD FOR ECONOMIZER (Furnished) L 11- 3'41298; 036firu048 r 15.311 ,ao OM fru 072 SIDE VIEW BAROMETRIC RELIEF HOOD FOR ECONOMIZER (Fumishod) Model A 0 c SIDE VIEW BAROMETRIC RELIEF HOOD FOR ECONOMIZER (Fumishod) Model A B C No. in. mm in. MITI is. mm 038.048 19-1/4 489 13 330 11-3/4 298 060.072 23-1/4 591 17 432 15-3/4 400 Project: 3000786011 LOWES #10 - TUKWILA WA Quote: 4000925551 LOWES #10 - TUKWILA WA Page 41 of 68 Last Changed: PENISTEN, JR Prepared On: 2018-06-06 Phone: 972-497-6786 Lennox Industries Inc. - Product Submittal System ID: RTU -10 Package Model: LCH060H4E Description: PKGEE/5TON/CONFIGURABLE UNIT CLEARANCES - INCHES (MM) OUTDOOR NR HOOD D i i *Unit Clearances A B C D Top Clearance in. mm In. mm In. mm in. mm Service Clearance 36 914 36 914 36 934 36 914 Unobstructed Minimum Operation Clearance 36 914 36 914 36 914 36 914 NOTE - Endre perimeter of unit base requires support when elevated above the mounting surface. ' Service Clearance - Requited *x removal of serviceable pats. Minimus Operation Clearance - Required ciearance for proper udtaperatbn. Project: 3000786011 LOWES #10 - TUKWILA WA Quote: 4000925551 LOWES #10 • TUKWILA WA Page 42 of 68 Last Changed: PENISTEN, JR Prepared On: 2018-06-06 Phone: 972-497-6786 Lennox Industries Inc. - Product Submittal System ID: RTU -11 Package Model: LGH060H4E Description: PKGGE/5TON/CONFIGURABLE HEATING PERFORMANCE Unit Type H/E LowInput H/E LowOutput H/E Highlnput H/E HighOutput System HeatOutput Packaged Gas Electric 81000 (Btuh) 65000 (Btuh) 108000 (Btuh) 86000 (Btuh) 86000 (Btuh) Gas Supply Connection H/E Heat Rise AFUE/ ThermalEff Number of Heating Stages Gas Supply Pressure 0.50 (in.) 39.8 (°F) 80 2 7 (in.WC) COOLING PERFORMANCE Refrigerant ARI EER ARI SEER ARI Total Power ARI GrossTotalCool ARI NetTotalCool Coil GrossTotalCool Unit NetTotalCool Coil GrossSensCool Unit NetSensCool Tube/Fin Humiditrol Refrigerant Charge R -410A 12.7 17.0 4700 (W) 61600 (Btuh) 60000 (Btuh) 64348 (Btuh) 61964 (Btuh) 56449 (Btuh) 54066 (Btuh) 17 LBS. 8 0Z. Number Compressors Number of Cooling Stages Condensate Drain Size Cooling OutdoorDB Cooling MixedDB Cooling MixedWB Coil DischargeDB Coil DischargeWB Unit DischargeDB Unit DischargeWB Coil MoistureRemoval System MoistRemoval 1 2 1.00 (in.) 82.0 (°F) 80.0 (°F) 64.0 (°F) 52.3 (°F) 52.3 (°F) 53.4 (°F) 52.9 (°F) 7.4 (lb/hr) 7.4 (lb/hr) SUPPLY FAN PERFORMANCE Supply AirFlow ExtStaticPress Supply SupplyFan Req'dPower SupplyFan NomPower Supply Fan Type SupplyDriveReq'd RPM Motor Torque Pct 2000 (cfm) 0.40 (in.WC) 1.00 (hp) 1.00 (hp) MSAV Direct Drive 989 (rpm) 71 TotalStaticPress Wet Coil Static Press Gas H/E Static Press Added Filter Static Press Humiditrol Static Press Economizer Static Press Air Filter Qty Air Filter Length Air Filter Width Air Filter Thickness 0.67 (in.WC) 0.10 (in.WC) 0.04 (in.WC) 0.05 (in.WC) 0.03 (in.WC) 0.05 (in.WC) 4 20.0 (in.) 20.0 (in.) 2.0 (in.) ELECTRICAL Voltage Frequency System MCA System MOCP Compressors RLA Cooling FLA Total Unit Oper Range -Nom Voltage 460V 3Ph 60 (Hz) 15.0 (amp) 20 (amp) 9.0 (amp) 14.8 (amp) +/- 10% SupplyFan FLA CondensingUnit FLA 3.7 (amp) 2.1 (amp) DIMENSIONS Cabinet Width Cabinet Length Cabinet Height Total Weight 47.0 (in.) 85.3 (in.) 46.9 (in.) 169 (lb) Downflow Supply Length Downflow Supply Width Downflow Return Length Downflow Return Width 20.0 (in.) 18.0 (in.) 29.0 (in.) 11.0 (in.) SOUND Outdoor Sound Rating 82 (db) Project: 3000786011 LOWES #10 - TUKWILA WA Quote: 4000925551 LOWES #10 - TUKWILA WA Page 43 of 68 Last Changed: PENISTEN, JR Prepared On: 2018-06-06 Phone: 972-497-6786 Lennox Industries Inc. - Product Submittal System ID: RTU -11 Package Model: LGH060H4E Description: PKGGE/5TON/CONFIGURABLE SYSTEM FEATURES Durable Outdoor Enamel Paint Finish Scroll Compressor Pre -charged Refrigeration System Expansion Valves High Capacity Driers Auto reset high & low pressure switch with strike 3 lockout feature in Prodigy unit controller Totally Enclosed Fan Motor PVC Coated Fan Guard Fan and Limit Controls Factory Test Operated Bonded for Grounding Internal Pressure Relief Valve Overload Protection Crankcase Heater Test Timed Off Control AGA -CGA Certified Units will operate cooling down to 0 degrees F (-17.7 degrees C) without additional controls. Redundant Comb. Gas Control Valve Electronic Flame Sensor Direct Spark Ignition Separate Compressor and Controls Compartment Advanced controls with Prodigy Control System Limited compressor warranty of 5 years Limited warranty on Prodigy Unit Controller of 3 years Limited warranty on all other components of 1 year See Limited Warranty Certificate included with unit for details INCLUDED SYSTEM OPTIONS - FACTORY INSTALLED SENSIBLE ECONOMIZER/W HOOD HIGH PERF ECONOMIZER 2 IN MERV8 FILTER BLOWER PROVING SWITCH CIRCUIT BREAKER CORROSION PROTECTION MULTI -STAGE AIR VOLUME HINGED ACCESS DOORS TUBE AND FIN COIL SYSTEM DIRTY FILTER SWITCH GFCI - FACTORY INSTALLED/NON-POWERED BAROMETRIC RELIEF DAMPERS/W HOOD HUMIDITROL PHASE MONITOR RA SMOKE DETECTOR STANDARD CAP NOVAR ETM -2051 INCLUDED SYSTEM OPTIONS - FIELD INSTALLED 21W06 1 A335MT13AE1- SNSR, TEMP RH Project: 3000786011 LOWES #10 - TUKWILA WA Quote: 4000925551 LOWES #10 - TUKWILA WA Page 44 of 68 Last Changed: PENISTEN, JR Prepared On: 2018-06-06 Phone: 972-497-6786 Lennox Industries Inc. - Product Submittal System ID: RTU -11 Package Model: LGH060H4E Description: PKGGE/5TON/CONFIGURABLE DIMENSIONS - INCHES (MM) CORNER WEIGHTS CENTER OF GRAVITY Model No. AA BB CC DD EE FF lbs. kg lbs. kg lbs. kg lbs. kg in. mm in. mm LGHO36 Base Unit 98 45 119 54 192 87 158 72 38.5 978 18 457 LGH036Max. Unit 137 62 155 70 250 113 221 100 40 1016 18 457 LGN048 Base Unit 104 47 126 57 202 92 167 76 38.5 978 18 457 LGH048 Max. Unit 145 66 164 74 264 120 233 106 40 1816 18 457 LGH060 Base Unit 118 54 144 65 232 105 191 87 38-5 978 18 457 LG11060 Max. Unit 164 75 186 84 299 136 264 120 40 1016 18 457 LGH072 Base Und 132 60 160 73 258 117 212 96 38.5 978 18 457 LGH072 Max. Unit 173 78 195 69 314 143 278 126 40 1016 18 457 LGH074 Base Und 132 60 160 73 258 117 212 96 38.5 978 18 457 LGH074 Max. UM 173 78 195 89 314 143 278 126 40 1016 18 457 -OPIIONS. Mar.. tirdt-Tha trikalt,LLINTERNALCFEINelaskileri ifeaai aamMandadSagaPaw&htistFa a. Galt Ma).Doe ratiekei►am n del a:demi battar MO apawadaest. 111 m•ss —i f� END VIEW mi 15 3. 1,71140 gearol Energencee Packaged Gas ! Bootie 3 to 6 Ton 1 Page 52 Project: 3000786011 LOWES #10 - TUKWILA WA Quote: 4000925551 LOWES #10 - TUKWILA WA Page 45 of 68 SIDE VIEW 11 Foaxu'TELOTS IHYZIZONAL *e*izc L iiCo@si.na SUPPLY AR orm Ertl) OPOCNG ,raw) sGR 154311 (Mhwut fmioinm) BACK VIEW Last Changed: PENISTEM, JR Prepared On: 2018-06-06 Phone: 972-497-6786 ail{ • t0®It10f 111r111Ellt i ll 00 Q—t d 112 s �-- ttaal 113V41121115)ie� 11 SIDE VIEW 11 Foaxu'TELOTS IHYZIZONAL *e*izc L iiCo@si.na SUPPLY AR orm Ertl) OPOCNG ,raw) sGR 154311 (Mhwut fmioinm) BACK VIEW Last Changed: PENISTEM, JR Prepared On: 2018-06-06 Phone: 972-497-6786 Lennox Industries Inc. - Product Submittal System ID: RTU -11 Package Model: LGH060H4E Description: PKGGE/5TON/CONFIGURABLE ACCESSORY DIMENSIONS - INCHES (MM) OUTDOOR AIR HOOD DETAIL FOR OPTIONAL ECONOMIZER AND BAROMETRIC RELIEF DAMPERS (Down -Flow Applications) OPTOONAL OUTDOOR AIR HOOD --�• (FumlDe0 wM Ecoromzrl OPTIONAL BAROMETPo RELIEF HCOD - 1� 113'412E3) 036111m 048 15.34 (an 060 0Th 072 (Fumkhed with Ecoromixr) OUTDOOR AIR HOOD FOR ECONOMIZER (Furnished) SIDE VIEW BAROMETRIC RELIEF HOOD FOR ECONOMIZER (Fumishod) 2.1/2 I6 Model A a C Mo. in. mm C mm (Fumkhed with Ecoromixr) OUTDOOR AIR HOOD FOR ECONOMIZER (Furnished) SIDE VIEW BAROMETRIC RELIEF HOOD FOR ECONOMIZER (Fumishod) 2.1/2 I6 Model A B C Mo. in. mm in. mm in. mm 038.048 19-1/4 489 13 330 11-3/4 298 060.072 23-1/4 591 17 432 15-3/4 400 Project: 3000786011 LOWES #10 - TUKWILA WA Quote: 4000925551 LOWES #10 - TUKWILA WA Page 46 of 68 Last Changed: PENISTEN, JR Prepared On: 2018-06-06 Phone: 972-497-6786 Lennox Industries Inc. - Product Submittal System ID: RTU -11 Package Model: LGH060H4E Description: PKGGE/5TON/CONFIGURABLE UNIT CLEARANCES - INCHES (MM) `l OUTDOOR AIR 14000 D B 1 ' Unit Clearance A B CD Top Clearance In. mm in. mm in. mm in. mm Service Clearance 48 1219 36 914 36 934 36 914 Unobstructed Clearance b3 Combustibles 36 914 1 25 1 25 1 25 Minimum Operation Clearance 36 914 36 914 36 914 36 914 NOTE - Endre perimeter af unit base requires naafi Men elevated above the mounting surface. ' Service clearance - Required for removal of serviceable parts. Clearance to combustibles - Required clearance to cambuslble material. Minimum Operation Clearance - Required clearance for proper unit operation. Project: 3000786011 LOWES #10 - TUKWILA WA Quote: 4000925551 LOWES #10 - TUKWILA WA Page 47 of 68 Last Changed: PENISTEN, JR Prepared On: 2018-06-06 Phone: 972-497-6786 Lennox Industries Inc. - Product Submittal System ID: RTU -12 Package Model: LGH048H4E Description: PKGGE/4TON/CONFIGURABLE HEATING PERFORMANCE Unit Type H/E HighInput H/E HighOutput System HeatOutput Packaged Gas Electric 65000 (Btuh) 52000 (Btuh) 52000 (Btuh) Gas Supply Connection H/E Heat Rise AFUE/ ThermalEff Number of Heating Stages Gas Supply Pressure 0.50 (in.) 30.1 (°F) 80 1 7 (in.WC) COOLING PERFORMANCE Refrigerant ARI EER ARI SEER ARI Total Power ARI GrossTotalCool ARI NetTotalCool Coil GrossTotalCool Unit NetTotalCool Coil GrossSensCool Unit NetSensCool Tube/Fin Humiditrol Refrigerant Charge R -410A 12.8 17.0 3800 (W) 50100 (Btuh) 49000 (Btuh) 51260 (Btuh) 49473 (Btuh) 45237 (Btuh) 43450 (Btuh) 12 LBS. 7 OZ. Number Compressors Number of Cooling Stages Condensate Drain Size Cooling OutdoorDB Cooling MixedDB Cooling MixedWB Coil DischargeDB Coil DischargeWB Unit DischargeDB Unit DischargeWB Coil MoistureRemoval System MoistRemoval 1 2 1.00 (in.) 82.0 (°F) 80.0 (°F) 64.0 (°F) 52.2 (°F) 52.2 (°F) 53.3 (°F) 52.9 (°F) 5.7 (lb/hr) 5.7 (lb/hr) SUPPLY FAN PERFORMANCE Supply AirFlow ExtStaticPress Supply SupplyFan Req'dPower SupplyFan NomPower Supply Fan Type SupplyDriveReq'd RPM Motor Torque Pct 1600 (cfm) 0.40 (in.WC) 0.75 (hp) 0.75 (hp) MSAV Direct Drive 1026 (rpm) 57 TotalStaticPress Wet Coil Static Press Added Filter Static Press Humiditrol Static Press Economizer Static Press Air Filter Qty Air Filter Length Air Filter Width Air Filter Thickness 0.63 (in.WC) 0.12 (in.WC) 0.04 (in.WC) 0.03 (in.WC) 0.04 (in.WC) 4 16.0 (in.) 20.0 (in.) 2.0 (in.) ELECTRICAL Voltage Frequency System MCA System MOCP Compressors RLA Cooling FLA Total Unit Oper Range -Nom Voltage 460V 3Ph 60 (Hz) 14.0 (amp) 15 (amp) 6.4 (amp) 11.6 (amp) +/- 10% SupplyFan FLA CondensingUnit FLA 3.1 (amp) 2.1 (amp) DIMENSIONS Cabinet Width Cabinet Length Cabinet Height Total Weight 47.0 (in.) 85.3 (in.) 38.9 (in.) 158 (lb) Downflow Supply Length Downflow Supply Width Downflow Return Length Downflow Return Width 20.0 (in.) 18.0 (in.) 29.0 (in.) 11.0 (in.) SOUND Outdoor Sound Rating 75 (db) Project: 3000786011 LOWES #10 - TUKWILA WA Quote: 4000925551 LOWES #10 - TUKWILA WA Page 48 of 68 Last Changed: PENISTEN, JR Prepared On: 2018-06-06 Phone: 972-497-6786 Lennox Industries Inc. - Product Submittal System ID: RTU -12 Package Model: LGH048H4E Description: PKGGE/4TON/CONFIGURABLE SYSTEM FEATURES Durable Outdoor Enamel Paint Finish Scroll Compressor Pre -charged Refrigeration System Expansion Valves High Capacity Driers Auto reset high & low pressure switch with strike 3 lockout feature in Prodigy unit controller Totally Enclosed Fan Motor PVC Coated Fan Guard Fan and Limit Controls Factory Test Operated Bonded for Grounding Internal Pressure Relief Valve Overload Protection Crankcase Heater Test Timed Off Control AGA -CGA Certified Units will operate cooling down to 0 degrees F (-17.7 degrees C) without additional controls. Redundant Comb. Gas Control Valve Electronic Flame Sensor Direct Spark Ignition Separate Compressor and Controls Compartment Advanced controls with Prodigy Control System Limited compressor warranty of 5 years Limited warranty on Prodigy Unit Controller of 3 years Limited warranty on all other components of 1 year See Limited Warranty Certificate included with unit for details INCLUDED SYSTEM OPTIONS - FACTORY INSTALLED SENSIBLE ECONOMIZER/W HOOD HIGH PERF ECONOMIZER 2 IN MERV8 FILTER BLOWER PROVING SWITCH CIRCUIT BREAKER CORROSION PROTECTION MULTI -STAGE AIR VOLUME HINGED ACCESS DOORS TUBE AND FIN COIL SYSTEM DIRTY FILTER SWITCH GFCI - FACTORY INSTALLED/NON-POWERED BAROMETRIC RELIEF DAMPERS/W HOOD HUMIDITROL PHASE MONITOR RA SMOKE DETECTOR STANDARD CAP NOVAR ETM -2051 INCLUDED SYSTEM OPTIONS - FIELD INSTALLED 21 W06 1 A335MT13AE1- SNSR, TEMP RH Project: 3000786011 LOWES #10 - TUKWILA WA Quote: 4000925551 LOWES #10 - TUKWILA WA Page 49 of 68 Last Changed: PENISTEN, JR Prepared On: 2018-06-06 Phone: 972-497-6786 Lennox Industries Inc. - Product Submittal System ID: RTU -12 Package Model: LGH048H4E Description: PKGGE/4TON/CONFIGURABLE DIMENSIONS - INCHES (MM) CORNER WEIGHTS CENTER OF GRAVITY Model No. AA BB CC DD EE FF tbs. kg lbs. kg tbs. kg tbs. kg in. mm in. mm LGH036 Base Unit 98 45 119 54 192 87 158 72 38.5 978 18 457 LGH036 Max. Unit 137 62 155 70 250 113 221 100 40 1016 18 457 LGH048 Base Unit 104 47 128 57 202 92 167 76 383 978 18 457 LGH048 Max. Unit 145 66 164 74 264 120 233 106 40 1016 18 457 LGH060 Base Unit 118 54 144 65 232 105 191 67 38.5 978 18 457 LGH060 Max. Unit 164 75 186 84 299 136 264 120 40 1016 18 457 LGH072 Base Unit 132 60 160 73 258 117 212 96 38.5 978 18 457 LGH072 Max. UM 173 78 195 89 314 143 278 126 40 1016 18 457 LGH074 Base Unit 132 60 160 73 258 117 212 96 38.5 978 18 457 LGH074 Max. UM 173 78 195 89 314 143 278 126 40 1016 18 457 Batiks •iuewtollt ND ttiTHB4ALCP110IG tiAaL tilt -The ueeR6illthaINTl3ILCPT10145 Wallet (Ecoemittek 8tadad Slate Pe Edict stFaa COM* etc). Does act iodate ameeoeies Mend tomaw iiybsffopou Talmo t 503 it 111.114 1! r 54l —N IIME K•14 END VIEW 1' } ( v► E+ergence• Packaged Gas / Electric 3 to 6 Ton 1 Paye 52 Project: 3000786011 LOWES #10 - TUKWILA WA Quote: 4000925551 LOWES #10 - TUKWILA WA Page 50 of 68 ettrale tiftl. CIONIVIIMMOUnaT 4X i< TCPVE1N tai in SIDE VIEW 1a* FOeefQJT CLOTS HOR /WM esort¢aNukL (Fork 1 42 Dn orErd) SMOM ( ) OPOC S Y 6412 FCrtAIN Pa 143) (w"w,+rmion.a r) BACK VIEW Last Changed: PENISTEN, JR Prepared On: 2018-06-06 Phone: 972-497-6786 6i4/ePIM 1� nor \I BEC ET 1L N GAS Mir . ," s ao ®t doj zs>a� t t ._ a UAW (21135} SIDE VIEW 1a* FOeefQJT CLOTS HOR /WM esort¢aNukL (Fork 1 42 Dn orErd) SMOM ( ) OPOC S Y 6412 FCrtAIN Pa 143) (w"w,+rmion.a r) BACK VIEW Last Changed: PENISTEN, JR Prepared On: 2018-06-06 Phone: 972-497-6786 Lennox Industries Inc. - Product Submittal System ID: RTU -12 Package Model: LGH048H4E Description: PKGGE/4TON/CONFIGURABLE ACCESSORY DIMENSIONS - INCHES (MM) OUTDOOR AIR HOOD DETAIL FOR OPTIONAL ECONOMIZER AND BAROMETRIC RELIEF DAMPERS (Down -Flow App Iications) 1 OPTIONAL OUTDOOR AIR HOOD (Fum151e0 wth Emromiten `12 (?Of; OPTIONAL BAROMETR I REUEFHCOO (� (Ft:meh.d will Emmaus* 11-3'412081036 thou 043 15.:VA ([(:01030 0v4 077 OUTDOOR AIR HOOD FOR ECONOMIZER (Furnished) SIDE VIEW BAROMETRIC RELIEF HOOD FOR ECONOMIZER (Furnished) Model A C OUTDOOR AIR HOOD FOR ECONOMIZER (Furnished) SIDE VIEW BAROMETRIC RELIEF HOOD FOR ECONOMIZER (Furnished) Model A B C No. in. mm in. ren in. mm 038.048 19-1/4 489 13 330 11-3/4 298 060.072 23-1/4 591 17 432 15-3/4 400 Project: 3000786011 LOWES #10 - TUKWILA WA Quote: 4000925551 LOWES #10 - TUKWILA WA Page 51 of 68 Last Changed: PENISTEN, JR Prepared On: 2018-06-06 Phone: 972-497-6786 Lennox Industries Inc. - Product Submittal System ID: RTU -12 Package Model: LGH048H4E Description: PKGGE/4TON/CONFIGURABLE UNIT CLEARANCES - INCHES (MM) t `l OUTDOOR AIR HOOD - D —► B i 1 ' Unit ClearanceA B C D Top CI.arancs in. mm in. mm In. mm in. mm Service Clearance 48 1219 36 914 36 934 36 914 Unobstructed Clearance to Combustibles 36 914 1 25 1 25 1 25 Minimum Operation Clearance 36 914 36 914 36 914 36 914 NOTE - Endre pertmerer of wit base requires support when elevated above the mounting surface. service aemance - Required for removal of serviceable parts. Clearance to Combustibles - Required clearance to combusri 1e material. Minimus Operation Clearance - Required clearance for proper at operation. Project: 3000786011 LOWES #10 - TUKWILA WA Quote: 4000925551 LOWES #10 - TUKWILA WA Page 52 of 68 Last Changed: PENISTEN, JR Prepared On: 2018-06-06 Phone: 972-497-6786 Lennox Industries Inc. - Product Submittal System ID: RTU -13 Package Model: LCH060H4E Description: PKGEE/5TON/CONFIGURABLE HEATING PERFORMANCE Unit Type H/E HighOutput System HeatOutput Packaged Electric/Electri 23519 (Btuh) 23519 (Btuh) Electric Heater H/E Heat Rise 7.5 (kW) 10.9 (°F) COOLING PERFORMANCE Refrigerant ARI EER ARI SEER ARI Total Power ARI GrossTotalCool ARI NetTotalCool Coil GrossTotalCool Unit NetTotalCool Coil GrossSensCool Unit NetSensCool Tube/Fin Humiditrol Refrigerant Charge R -410A 12.7 17.0 4700 (W) 61600 (Btuh) 60000 (Btuh) 64348 (Btuh) 61964 (Btuh) 56449 (Btuh) 54066 (Btuh) 16 LBS. 0 OZ. Number Compressors Number of Cooling Stages Condensate Drain Size Cooling OutdoorDB Cooling MixedDB Cooling MixedWB Coil DischargeDB Coil DischargeWB Unit DischargeDB Unit DischargeWB Coil MoistureRemoval System MoistRemoval 1 2 1.00 (in.) 82.0 (°F) 80.0 CO 64.0 (°F) 52.3 (°F) 52.3 (°F) 53.4 (°F) 52.9 (°F) 7.4 (lb/hr) 7.4 (lb/hr) SUPPLY FAN PERFORMANCE Supply AirFlow ExtStaticPress Supply SupplyFan Req'dPower SupplyFan NomPower Supply Fan Type SupplyDriveReq'd RPM Motor Torque Pct 2000 (cfm) 0.40 (in.WC) 1.00 (hp) 1.00 (hp) MSAV Direct Drive 1023 (rpm) 74 TotalStaticPress Wet Coil Static Press Electric H/E Static Press Added Filter Static Press Humiditrol Static Press Economizer Static Press Air Filter Qty Air Filter Length Air Filter Width Air Filter Thickness 0.78 (in.WC) 0.10 (in.WC) 0.15 (in.WC) 0.05 (in.WC) 0.03 (in.WC) 0.05 (in.WC) 4 20.0 (in.) 20.0 (in.) 2.0 (in.) ELECTRICAL Voltage Frequency System MCA System MOCP Compressors RLA Cooling FLA Total Unit Oper Range -Nom Voltage 460V 3Ph 60 (Hz) 16.0 (amp) 20 (amp) 7.2 (amp) 13.0 (amp) +/- 10% SupplyFan FLA CondensingUnit FLA CondenserFan Power 3.7 (amp) 2.1 (amp) 350 (W) DIMENSIONS Cabinet Width Cabinet Length Cabinet Height Total Weight 47.0 (in.) 85.3 (in.) 46.9 (in.) 192 (lb) Downflow Supply Length Downflow Supply Width Downflow Return Length Downflow Return Width 20.0 (in.) 18.0 (in..) 29.0 (in.) 11.0 (in.) SOUND Outdoor Sound Rating 82 (db) Project: 3000786011 LOWES #10 - TUKWILA WA Quote: 4000925551 LOWES #10 - TUKWILA WA Page 53 of 68 Last Changed: PENISTER JR Prepared On: 2018-06-06 Phone: 972-497-6786 Lennox Industries Inc. - Product Submittal System ID: RTU -13 Package Model: LCH060H4E Description: PKGEE/5TON/CONFIGURABLE SYSTEM FEATURES Durable Outdoor Enamel Paint Finish Scroll Compressor Pre -charged Refrigeration System Expansion Valves High Capacity Driers Auto reset high & low pressure switch with strike 3 lockout feature in Prodigy unit controller Totally Enclosed Fan Motor PVC Coated Fan Guard Fan and Limit Controls Factory Test Operated Bonded for Grounding Internal Pressure Relief Valve Overload Protection Crankcase Heater Test Timed Off Control Units will operate cooling down to 0 degrees F (-17.7 degrees C) without additional controls. Separate Compressor and Controls Compartment Advanced controls with Prodigy Control System Limited compressor warranty of 5 years Limited warranty on Prodigy Unit Controller of 3 years Limited warranty on all other components of 1 year See Limited Warranty Certificate included with unit for details INCLUDED SYSTEM OPTIONS - FACTORY INSTALLED ELECTRIC HEAT SENSIBLE ECONOMIZER/W HOOD HIGH PERF ECONOMIZER 2 IN MERV8 FILTER BLOWER PROVING SWITCH CIRCUIT BREAKER CORROSION PROTECTION MULTI -STAGE AIR VOLUME HINGED ACCESS DOORS TUBE AND FIN COIL SYSTEM DIRTY FILTER SWITCH GFCI - FACTORY INSTALLED/NON-POWERED BAROMETRIC RELIEF DAMPERS/W HOOD HUMIDITROL PHASE MONITOR RA SMOKE DETECTOR STANDARD CAP NOVAR ETM -2051 INCLUDED SYSTEM OPTIONS - FIELD INSTALLED 21W06 1 A335MT13AE1- SNSR, TEMP RH Project: 3000786011 LOWES #10 - TUKWILA WA Quote: 4000925551 LOWES #10 - TUKWILA WA Page 54 of 68 Last Changed: PENISTEN, JR Prepared On: 2018-06-06 Phone: 972-497-6786 Lennox Industries Inc. - Product Submittal System ID: RTU -13 Package Model: LCH060H4E Description: PKGEE/STON/CONFIGURABLE DIMENSIONS - INCHES (MM) CORNER WEIGHTS CENTER OF GRAVITY Model No. AA B8 CC DD EE FF lbs. kg lbs. kg tbs. kg lbs. kg in. mm in. mm LCH336 Base Unit 92 42 112 Si 180 82 148 67 38.5 978 18 457 LCH036 Max_ Unit 133 61 151 69 243 110 215 98 40 1016 18 457 LCHD48 Base Unit 97 44 118 54 190 87 157 71 38.5 978 18 457 LCH048 Max_ Unit 139 63 158 72 254 115 224 102 40 1016 18 457 LCH060 Base Unit 112 51 136 62 219 100 181 82 383 978 18 457 LCH060 Max_ Unit 159 72 180 82 290 132 257 117 40 1016 18 457 LCH072 Base Unit 126 57 152 69 246 112 202 92 38.5 978 18 457 LC11072 Max. Unit 168 76 190 86 306 139 270 123 40 1016 18 457 LCH074 Base Unit 126 57 152 69 246 112 202 92 38.5 978 18 457 LCH074 Max UM 168 76 190 86 306 139 270 123 40 1016 18 457 Base -The WINO rte. UM- lbw ur* WIERNAL .OPIION3Wallet ¢ Sordid Stift PermWaist Fan,Oariak.elo}Dosnaltadudraooesuarsesfsid buderl 1stabreefe NW. iiltncDIMM1111111111•11•1•1141 07-1 gg si it 0001 END VIEW Project: 3000786011 LOWES #10 - TUKWILA WA Quote: 4000925551 LOWES #10 - TUKWILA WA Page 55 of 68 1 L®T$GN ea Mr 0200 AMU aaeaai asonutr csxersxsrq VW MEW pass) SIDE VIEW FOQ Qz TCOTS 110%2ONVrAL LIR IIIVUONTAL b4R t mina =WAY AA 04c; iiTU 4w (1 c 090010090010 a� rscl as+s» BACK VIEW `S Last Changed: PENISTEN, JR Prepared On: 2018-06-06 Phone: 972-497-6786 wA t> L.,.. II z '- ' r II .. r•I MININIIIIIism= WININNI•I.I s 26�t! f�1 es/xR1eo)wan _� SIDE VIEW FOQ Qz TCOTS 110%2ONVrAL LIR IIIVUONTAL b4R t mina =WAY AA 04c; iiTU 4w (1 c 090010090010 a� rscl as+s» BACK VIEW `S Last Changed: PENISTEN, JR Prepared On: 2018-06-06 Phone: 972-497-6786 Lennox Industries Inc. - Product Submittal System ID: RTU -13 Package Model: LCH060H4E Description: PKGEE/5TON/CONFIGURABLE ACCESSORY DIMENSIONS - INCHES (MM) OUTDOOR AIR HOOD DETAIL FOR OPTIONAL ECONOMIZER AND BAROMETRIC RELIEF DAMPERS (Down -Flow Applications) OPTIONAL OUTDOOR AIR HOOD (Fumyner wm Emromizen 1 — t2 1�1 OPTIONAL BAROMETRI RELIEF HCOD - I� (Freer! Wirt &oromar) 113'41288{ 036 euu 048 15.314 /!!911060 try 072 OUTDOOR AIR HOOD FOR ECONOMIZER (Furnishod) '.J SIDE VIEW BAROMETRIC RELIEF HOOD FOR ECONOMIZER (Fumishsd) Model A c OUTDOOR AIR HOOD FOR ECONOMIZER (Furnishod) '.J SIDE VIEW BAROMETRIC RELIEF HOOD FOR ECONOMIZER (Fumishsd) Model A a C No. in. mm in. tmn in. mm 038.048 19-1/4 489 13 330 11-3/4 298 060.072 23-1/4 591 17 432 15-3/4 400 Project: 3000786011 LOWES #10 - TUKWILA WA Quote: 4000925551 LOWES #10 - TUKWILA WA Page 56 of 68 Last Changed: PENISTEN, JR Prepared On: 2018-06-06 Phone: 972-497-6786 Lennox Industries Inc. - Product Submittal System ID: RTU -13 Package Model: LCH060H4E Description: PKGEE/5TON/CONFIGURABLE UNIT CLEARANCES - INCHES (MM) OUTDOOR AIR HOOD D B t t Unit Clearance A B C D Top Clearance In. mm In. mm In. mm in. mm Service Clearance 36 914 36 914 36 934 36 914 Unobstructed Minimum Operation Clearance 38 914 36 914 36 914 36 914 NOTE - Entise perimeter cf unit base requires stpport when elevated wove the mounting surface. Service Clearance - Required ler removal of serviceable pens. Minimum Operation Clearance - Required clearance for proper unit operation. Project: 3000786011 LOWES #10 - TUKWILA WA Quote: 4000925551 LOWES #10 - TUKWILA WA Page 57 of 68 Last Changed: PENISTEN, JR Prepared On: 2018-06-06 Phone: 972-497-6786 Lennox Industries Inc.. - Product Submittal System ID: RTU -15,16 Package Model: LGH036H4E Description: PKGGE/3TON/CONFIGURABLE HEATING PERFORMANCE Unit Type H/E LowInput H/E LowOutput H/E HighInput H/E HighOutput System HeatOutput Packaged Gas Electric 81000 (Btuh) 65000 (Btuh) 108000 (Btuh) 86000 (Btuh) 86000 (Btuh) Gas Supply Connection H/E Heat Rise AFUE/ ThermalEff Number of Heating Stages Gas Supply Pressure 0.50 (in.) 66.4 (°F) 80 2 7 (in.WC) COOLING PERFORMANCE Refrigerant ARI EER ARI SEER ARI Total Power ARI GrossTotalCool ARI NetTotalCool Tube/Fin Humiditrol Refrigerant Charge R -410A 12.5 17.0 2800 (W) 36600 (Btuh) 36000 (Btuh) 9 LBS. 12 0Z. Number Compressors Number of Cooling Stages Condensate Drain Size Cooling OutdoorDB Cooling MixedDB Cooling MixedWB 1 2 1.00 (in.) 82.0 (°F) 80.0 (°F) 64.0 (°F) SUPPLY FAN PERFORMANCE ExtStaticPress Supply SupplyFan Req'dPower SupplyFan NomPower Supply Fan Type 0.40 (in.WC) 0.50 (hp) 0.50 (hp) MSAV Direct Drive TotalStaticPress Gas H/E Static Press Added Filter Static Press Humiditrol Static Press Economizer Static Press Air Filter Qty Air Filter Length Air Filter Width Air Filter Thickness 0.51 (in.WC) 0.02 (in.WC) 0.04 (in.WC) 0.01 (in.WC) 0.04 (in.WC) 4 16.0 (in.) 20.0 (in.) 2.0 (in.) ELECTRICAL Voltage Frequency System MCA System MOCP Compressors RLA Cooling FLA Total Unit Oper Range -Nom Voltage 460V 3Ph 60 (Hz) 12.0 (amp) 15 (amp) 4.5 (amp) 8.8 (amp) +/- 10% SupplyFan FLA CondensingUnit FLA 2.2 (amp) 2.1 (amp) DIMENSIONS Cabinet Width Cabinet Length Cabinet Height Total Weight 47.0 (in.) 85.3 (in.) 38.9 (in.) 166 (lb) Downflow Supply Length Downflow Supply Width Downflow Return Length Downflow Return Width 20.0 (in.) 18.0 (in.) 29.0 (in.) 11.0 (in.) SOUND Outdoor Sound Rating 75 (db) Project: 3000786011 LOWES #10 - TUKWILA WA Quote: 4000925551 LOWES #10 - TUKWILA WA Page 58 of 68 Last Changed: PENISTEN, JR Prepared On: 2018-06-06 Phone: 972-497-6786 Lennox Industries Inc. - Product Submittal System ID: RTU -15,16 Package Model: LGH036H4E Description: PKGGE/3TON/CONFIGURABLE SYSTEM FEATURES Durable Outdoor Enamel Paint Finish Scroll Compressor Pre -charged Refrigeration System Expansion Valves High Capacity Driers Auto reset high & low pressure switch with strike 3 lockout feature in Prodigy unit controller Totally Enclosed Fan Motor PVC Coated Fan Guard Fan and Limit Controls Factory Test Operated Bonded for Grounding Internal Pressure Relief Valve Overload Protection Crankcase Heater Test Timed Off Control AGA -CGA Certified Units will operate cooling down to 0 degrees F (-17.7 degrees C) without additional controls. Redundant Comb. Gas Control Valve Electronic Flame Sensor Direct Spark Ignition Separate Compressor and Controls Compartment Advanced controls with Prodigy Control System Limited compressor warranty of 5 years Limited warranty on Prodigy Unit Controller of 3 years Limited warranty on all other components of 1 year See Limited Warranty Certificate included with unit for details INCLUDED SYSTEM OPTIONS - FACTORY INSTALLED SENSIBLE ECONOMIZER/NV HOOD HIGH PERF ECONOMIZER 2 IN MERV8 FILTER BLOWER PROVING SWITCH CIRCUIT BREAKER CORROSION PROTECTION MULTI -STAGE AIR VOLUME HINGED ACCESS DOORS TUBE AND FIN COIL SYSTEM DIRTY FILTER SWITCH GFCI - FACTORY INSTALLED/NON-POWERED BAROMETRIC RELIEF DAMPERS/W HOOD HUMIDITROL PHASE MONITOR RA SMOKE DETECTOR STANDARD CAP NOVAR ETM -2051 INCLUDED SYSTEM OPTIONS - FIELD INSTALLED 21W06 2 A335MT13AE1- SNSR, TEMP RH Project: 3000786011 LOWES #10 - TUKWILA WA Quote: 4000925551 LOWES #10 - TUKWILA WA Page 59 of 68 Last Changed: PENISTEN, JR Prepared On: 2018-06-06 Phone: 972-497-6786 Lennox Industries Inc. - Product Submittal System ID: RTU -15,16 Package Model: LGH036H4E Description: PKGGE/3TON/CONFIGURABLE DIMENSIONS - INCHES (MM) CORNER WEIGHTS CENTER OF GRAVITY Model No. AA BB CC DD EE FF lbs. kg lbs. kg tbs. kg lbs. kg in. mm in. mm LGH1336 Base Unit 98 45 119 54 192 87 158 72 38.5 978 18 457 LGHD36 Max. Unit 137 62 155 70 250 113 221 100 40 1016 18 457 LGH048 Base Ulna 104 47 128 57 2D2 92 167 76 38.5 978 18 457 1G11048 Max. UM 145 68 164 74 264 120 233 106 40 1016 18 457 LGH060 Base Unit 118 54 144 65 232 105 191 87 38.5 978 18 457 LGH060 Max. Unit 164 75 186 84 299 136 264 120 40 1016 18 457 LG/C72 Base Unit 132 60 160 73 258 117 212 96 38.5 978 18 457 LGH072 Max.Unit 173 78 195 89 314 143 278 126 40 1016 18 457 LGH074 Base Unit 132 60 160 73 258 117 212 96 38.5 978 18 457 L011074 Max. Unit 173 78 195 89 314 143 278 126 40 1016 18 457 Brie Uai •The uuteit ND NIERPOLCPTIIVEL. MacUrB-7heunRuiltALLNTERNALCIPIlON3Wald lEoadoekexMand d Bak Pow &MusaFan, Carbals,Eta}Dan tsRfMudeaocessoeleseden! btaster NOtmopeiwra H ts•nr to ftp, NI•NEMS E•I• END VEW sa ti 1 1 Wind 10 11 Emergence' Packaged Gas I Electric 3 to 6 Ton 1 Paye 52 Project: 3000786011 LOWES #10 - TUKWILA WA Quote: 4000925551 LOWES #10 - TUKWILA WA Page 60 of 68 SIDE VIEW 1 CM FOR1QAT CLOTS 1401420NAd. HORIZONSU. (nom 12 Co erErd) OP DOM n1 SUPPLY AR 0�l 412 ;MORN 1112 ¢b) (+t) BACK VIEW Last Changed: PENISTEN, JR Prepared On: 2018-06-06 Phone: 972-497-6786 134% PIMKM 1 F WV\ r iir (14 3 ab Q I doi s 20412 47� PM e� 115.1/4 (2165) �-e-61 SIDE VIEW 1 CM FOR1QAT CLOTS 1401420NAd. HORIZONSU. (nom 12 Co erErd) OP DOM n1 SUPPLY AR 0�l 412 ;MORN 1112 ¢b) (+t) BACK VIEW Last Changed: PENISTEN, JR Prepared On: 2018-06-06 Phone: 972-497-6786 Lennox Industries Inc. - Product Submittal System ID: RTU -15,16 Package Model: LGH036H4E Description: PKGGE/3TON/CONFIGURABLE ACCESSORY DIMENSIONS - INCHES (MM) OUTDOOR AIR HOOD DETAIL FOR OPTIONAL ECONOMIZER AND BAROMETRIC RELIEF DAMPERS (Down -Flow Applications) OPTIONAL OUTDOOR AIR HOOD (Fumaned with Economizen J It - 3'4268; 036 Neu 048 1 15.34(Lfd 066 fru 072 -- OPTIONAL BAROMETRIC REUEFHCOO FumkI.d with Ecoroniart OUTDOOR AIR HOOD FOR ECONOMIZER (Fumishod) SIDE VIEW BAROMETRIC RELIEF HOOD FOR ECONOMIZER (Furnished) Model A B C No. in. mm in. mm in. mm 038.048 19-1/4 489 13 330 11-3/4 298 060.072 23-1/4 591 17 432 15-314 400 Project: 3000786011 LOWES #10 - TUKWILA WA Quote: 4000925551 LOWES #10 - TUKWILA WA Page 61 of 68 Last Changed: PENISTEN, JR Prepared On: 2018-06-06 Phone: 972-497-6786 Lennox Industries Inc. - Product Submittal System ID: RTU -15,16 Package Model: LGH036H4E Description: PKGGE/3TON/CONFIGURABLE UNIT CLEARANCES - INCHES (MM) OUTDOOR AIR HOOD D—► B i I Unit Clearance A B C D Top Clearance In. mm in. mm in. mm in. mm Service Clearance 48 1219 36 914 36 934 36 914 Unobstructed Clearance to Combustbles 36 914 1 25 1 25 1 25 Minimum Operation Clearance 36 914 36 914 36 914 36 914 NOTE - Entire perimeter of unit base requires support when elevated above the mounting surface. Service Clearance - Required for removal of serviceable parts. Clearance to Combustibles - Required dears ce b combustible material. Minimum Operation Clearance - Required clearance for proper unit operation. Project: 3000786011 LOWES #10 -TUKWILA WA Quote: 4000925551 LOWES #10 - TUKWILA WA Page 62 of 68 Last Changed: PENISTEN, JR Prepared On: 2018-06-06 Phone: 972-497-6786 Lennox Industries Inc. - Product Submittal System ID: RTU -18 Package Model: LCH048H4E Description: PKGEE/4TON/CONFIGURABLE HEATING PERFORMANCE Unit Type H/E HighOutput System HeatOutput Packaged Electric/Electri 47037 (Btuh) 47037 (Btuh) Electric Heater H/E Heat Rise 15.0 (kW) 27.2 (°F) COOLING PERFORMANCE Refrigerant ARI EER ARI SEER ARI Total Power ARI GrossTotalCool ARI NetTotalCool Coil GrossTotalCool Unit NetTotalCool Coil GrossSensCool Unit NetSensCool Tube/Fin Humiditrol Refrigerant Charge R -410A 12.8 17.0 3800 (W) 50100 (Btuh) 49000 (Btuh) 51260 (Btuh) 49473 (Btuh) 45237 (Btuh) 43450 (Btuh) 12 LBS. 7 OZ. Number Compressors Number of Cooling Stages Condensate Drain Size Cooling OutdoorDB Cooling MixedDB Cooling MixedWB Coil DischargeDB Coil DischargeWB Unit DischargeDB Unit DischargeWB Coil MoistureRemoval System MoistRemoval 1 2 1.00 (in.) 82.0 (°F) 80.0 (°F) 64.0 (°F) 52.2 (°F) 52.2 (°F) 53.3 (°F) 52.9 (°F) 5.7 (lb/hr) 5.7 (lb/hr) SUPPLY FAN PERFORMANCE Supply AirFlow ExtStaticPress Supply SupplyFan Req'dPower SupplyFan NomPower Supply Fan Type SupplyDriveReq'd RPM Motor Torque Pct 1600 (cfin) 0.40 (in.WC) 0.75 (hp) 0.75 (hp) MSAV Direct Drive 1054 (rpm) 61 TotalStaticPress Wet Coil Static Press Electric H/E Static Press Added Filter Static Press Humiditrol Static Press Economizer Static Press Air Filter Qty Air Filter Length Air Filter Width Air Filter Thickness 0.75 (in.WC) 0.12 (in.WC) 0.12 (in.WC) 0.04 (in.WC) 0.03 (in.WC) 0.04 (in.WC) 4 16.0 (in.) 20.0 (in.) 2.0 (in.) ELECTRICAL Voltage Frequency System MCA System MOCP Compressors RLA Cooling FLA Total Unit Oper Range -Nom Voltage 460V 3Ph 60 (Hz) 27.0 (amp) 30 (amp) 6.4 (amp) 11.6 (amp) +/- 10% SupplyFan FLA CondensingUnit FLA CondenserFan Power 3.1 (amp) 2.1 (amp) 165 (W) DIMENSIONS Cabinet Width Cabinet Length Cabinet Height Total Weight 47.0 (in.) 85.3 (in.) 38.9 (in.) 189 (lb) Downflow Supply Length Downflow Supply Width Downflow Return Length Downflow Return Width 20.0 (in.) 18.0 (in.) 29.0 (in.) 11.0 (in.) SOUND Outdoor Sound Rating 75 (db) Project: 3000786011 LOWES #10 - TUKWILA WA Quote: 4000925551 LOWES #10 - TUKWILA WA Page 63 of 68 Last Changed: PENISTEN, JR Prepared On: 2018-06-06 Phone: 972-497-6786 Lennox Industries Inc, - Product Submittal System ID: RTU -18 Package Model: LCH048H4E Description: PKGEE/4TON/CONFIGURABLE SYSTEM FEATURES Durable Outdoor Enamel Paint Finish Scroll Compressor Pre -charged Refrigeration System Expansion Valves High Capacity Driers Auto reset high & low pressure switch with strike 3 lockout feature in Prodigy unit controller Totally Enclosed Fan Motor PVC Coated Fan Guard Fan and Limit Controls Factory Test Operated Bonded for Grounding Internal Pressure Relief Valve Overload Protection Crankcase Heater Test Timed Off Control Units will operate cooling down to 0 degrees F (-17.7 degrees C) without additional controls. Separate Compressor and Controls Compartment Advanced controls with Prodigy Control System Limited compressor warranty of 5 years Limited warranty on Prodigy Unit Controller of 3 years Limited warranty on all other components of 1 year See Limited Warranty Certificate included with unit for details INCLUDED SYSTEM OPTIONS - FACTORY INSTALLED ELECTRIC HEAT SENSIBLE ECONOMIZER/W HOOD HIGH PERF ECONOMIZER 2 IN MERV8 FILTER BLOWER PROVING SWITCH CIRCUIT BREAKER CORROSION PROTECTION MULTI -STAGE AIR VOLUME HINGED ACCESS DOORS TUBE AND FIN COIL SYSTEM DIRTY FILTER SWITCH GFCI - FACTORY INSTALLED/NON-POWERED BAROMETRIC RELIEF DAMPERS/W HOOD HUMIDITROL PHASE MONITOR RA SMOKE DETECTOR STANDARD CAP NOVAR ETM -2051 INCLUDED SYSTEM OPTIONS - FIELD INSTALLED 21 W06 1 A335MT13AE1- SNSR, TEMP RH Project: 3000786011 LOWES #10 - TUKWILA WA Quote: 4000925551 LOWES #10 - TUKWILA WA Page 64 of 68 Last Changed: PENISTEN, JR Prepared On: 2018-06-06 Phone: 972-497-6786 Lennox Industries Inc. - Product Submittal System ID: RTU -18 Package Model: LCH048H4E Description: PKGEE/4TON/CONFIGURABLE DIMENSIONS - INCHES (MM) CORNER WEIGHTS CENTER OF GRAVITY Model No. AA BB CC DD EE FF lbs. kg lbs. kg lbs. kg Ria. kg in. mm in. mm LCH036 Bsse Unit 92 42 112 51 180 82 148 67 38.5 978 18 457 LCH03S Max. Unit 133 61 151 69 243 110 215 98 40 1016 18 457 LC H048 Base Unit 97 44 118 54 190 87 157 71 38.5 978 18 457 LCH048 Max. Unit 139 63 158 72 254 115 224 102 40 1016 18 457 LCH060 Base Una 112 51 138 62 219 100 181 82 38.5 978 18 457 LCH060 Max. Unit 159 72 180 82 290 132 257 117 40 1016 18 457 LCH072 Base Unit 126 57 152 69 246 112 202 92 38.5 978 18 457 LCH072 Max. Una 168 76 190 86 306 139 270 123 40 1016 18 457 LCH074 Base Unit 126 57 152 69 246 112 202 92 38.5 978 18 457 LCH074 Max the 168 76. 490 86 306 139 270 123 40 1016 18 457 Base that-Thrmitult NDtrout OPIlON£ titacttiril-lirwituthilaL INTE N&OPilO1Staaslaled�E be atarhtyoftitlCpalreduest I�—neo—y Ir a jti z Irtn END VIEW Project: 3000786011 LOWES #10 - TUKWILA WA Quote: 4000925551 LOWES #10 - TUKWILA WA Page 65 of 68 �StuslEdStale #brEetaatFaris. C uta's.ffit<OoesadbadraoeassptYselmd MOMS .00toam►aaimat ,axaritaatat TCPV ) sot pro WING HOES 164 (Ma) BAss SIDE VIEW fCOURT StOIR Nom. 'ZOl4TAL HD',t! ONTAL tram. a-hdi ad MPFLY AES n at ICtuau Aa 0 pa BACK VIEW090154 'a Last Changed: PENISTEN, JR Prepared On: 2018-06-06 Phone: 972-497-6786 Lennox Industries Inc. - Product Submittal System ID: RTU -18 Package Model: LCH448H4E Description: PKGEE/4TON/CONFIGURABLE ACCESSORY DIMENSIONS - INCHES (MM) OUTDOOR AIR HOOD DETAIL FOR OPTIONAL ECONOMIZER AND BAROMETRIC RELIEF DAMPERS (Down -Flow Applications) OPTIONAL OUTDOOR AIR FOOD (FumaNe0 wth Eooromizerl 11-3'41280{ 036 euu 048 15.34 (taA1060 fru 072 OPTIONAL BAROMETRIC RELIEF HCOD ;FumirllW u4h Eoromizr) OUTDOOR AIR HOOD FOR ECONOMIZER (Furnished) SIDE VIEW BAROMETRIC RELIEF HOOD FOR ECONOMIZER (Furnished) Model No. 038.048 060.072 A in. Mel B in. mm 191/4 489 I 13 330 23-1/4 591 1 17 432 C in. mm 11-3/4 298 15-3/4 400 Project: 3000786011 LOWES #10 - TUKWILA WA Quote: 4000925551 LOWES #10 - TUKWILA WA Page 66 of 68 Last Changed: PENISTEN, JR Prepared On: 2018-06-06 Phone: 972-497-6786 Lennox Industries Inc. - Product Submittal System ID: RTU -18 Package Model: LCH048H4E Description: PKGEE/4TON/CONFIGURABLE UNIT CLEARANCES - INCHES (MM) 1 `l OUTDOOR NR HOOD — D— B t "l t Unit Clearance A B C D Top Clearance in. mm In. mm In. mm in. mm Service Clearance 36 914 36 914 36 934 36 914 Unobstructed Minimum Operation Clearance 36 914 36 914 36 914 36 914 NOTE - Entire perimeter of uNt base requires steport when elevated above the mouroig surface. Service Clearance - Required lir removal of serviceable parts. Minimum Operation Clearance - Required a for proper unit operation. Project: 3000786011 LOWES #10 - TUKWILA WA Quote: 4000925551 LOWES #10 - TUKWILA WA Page 67 of 68 Last Changed: PENISTEN, JR Prepared On: 2018-06-06 Phone: 972-497-6786 Lennox Industries Inc. - Product Submittal MISCELLANEOUS MATERIALS X9107 DPT DP-FPS01 FLAT PLATE TEMP SENSOR 77N39 EG T8100 -D -LN CO2 DETECTOR/WHITE/WALL COMSD Third Party EOC Project: 3000786011 LOWES #10 - TUKWILA WA Quote: 4000925551 LOWES #10 - TUKWILA WA Page 68 of 68 Last Changed: PENISTEN, JR Prepared On: 2018-06-06 Phone: 972-497-6786 L©1 Cca[g<11 Cast/LogrE© Lioe-aps VoyagerTM 121/2-25 Tons — 60 Hz REVIEWED FOR CODE COMPLIANCE APPROVED OCT 10 2018 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA AUG 2 1 2018 PERMIT CENTER Packaged Cooling (TC*) Packaged Gas/Electric (YC*) December 2006 RT-PRCO24-EN Contents Introduction 2 Features and Benefits 4 Application Considerations 11 Selection Procedure 12 Model Number Description 14 General Data 16 Performance Data 26 Controls 72 Electrical Data . 74 Jobsite Connections . 83 Typical Wiring . 84 Dimensional Data . 92 Weights ... 99 Mechanical Specifications 102 RT-PRCO24-EN 3 .TRAM T C D 150 Model Number Description C 3 0 O A A 12 3 456 7 8 9 DIGIT 1,2 — UNIT TYPE TC Packaged Cooling, Electric Heat TF With Factory Installed Options YC Packaged Gas/Electric YF With Factory Installed Options DIGIT 3 — AIRFLOW CONFIGURATION D Downflow H Horizontal DIGIT 4,5,6 — NOMINAL GROSS COOLING CAPACITY (MBh) 150 121/2 Tons Standard Efficiency 151 121h Tons High Efficiency 180 15 Tons Standard Efficiency 181 15 Tons High Efficiency 210 17'/z Tons Standard Efficiency 211 171h Tons High Efficiency 240 20 Tons Standard Efficiency 241 20 Tons High Efficiency 300 25 Tons Standard Efficiency 301 25 Tons High Efficiency DIGIT 7 — MAJOR DESIGN SEQUENCE DIGIT 8 — VOLTAGE SELECTION 3 208-230/60/3 4 460/60/3 W 575/60/3 K 380/60/3 DIGIT 9,10 — FACTORY INSTALLED OPTIONS Note: 00 OA OB OC OF OG OH OJ OK OL OM ON OP OR (Applicable to Digit 1, 2 T models only) No Factory -installed Options Factory -installed Economizer Oversized Motor Downflow Economizer and Oversized Motor Trane Communications Interface (TCI) Downflow Economizer and TCI TXV/Face-Split Evaporator Oversized Motor and TXV Face -Split Evaporator Downflow Economizer, Oversized Motor, and TXV Face -Split Evaporator Downflow Economizer with TXV/Face-Split Evaporator Reheat Coil Downflow Economizer and Reheat Coil Oversized Motor and Reheat Coil Downflow Economizer, Oversized Motor and Reheat Coil DIGIT 9 — HEATING CAPACITY Note: (Applicable to Digit 1, 2 Y models only) L Low Heat M Medium Heat H High Heat 10 11 12 DIGIT 10 — FACTORY INSTALLED OPTIONS17 Note: (Applicable to Digit 1, 2 Y models only) 0 Packed Stock, No Options A Downflow Economizer.' B Oversized Motor? C Downflow Economizer and Oversized Motors F Trane Communications Interface (TCI)2,7 G Downflow Economizer and TCI1,2 H TXV/Face-Split Evaporator16 J Oversized Motor and TXV/Face Split Evaporator16 K Downflow Economizer, Oversized Motor, and TXV/Face Split Evaporator1,16 L Downflow Economizer with TXV Face -Split Evaporator7.16 M Reheat CoiI3,16 N Downflow Economizer and Reheat Coil1,3,16 P Oversized Motor and Reheat Coil1,3,16 R Downflow Economizer, Oversized Motor and Reheat Coi11,3,16 DIGIT 11 — MINOR DESIGN SEQUENCE DIGIT 12 — SERVICE SEQUENCE Note: Explanation of Model Number Notes located on the following page. Note: Most Factory Installed Options (FLOPS) available for Downflow Air Discharge units only. Please verify with ordering system for availability. 14 RT PRCO24-E N • .6 TRINE' Model Number Description Options *Factory Installed Options17 • 2" Pleated Filters7,3 • Black Epoxy Pre -Coated Coils? • Dehumidification Option3,14,16 • Differential Pressure Switches • High Efficiency Motors7 • Hinged Access Doors • Novar Return Air Sensor9 • Novar Unit Controls$ • Powered or Unpowered Convenience Outlet6 • Stainless Steel Heat Exchanger with 10 -year warranty? • Supply and/or Return Air Smoke Detector4,13 • Thermal Expansion VaIve16 • Through the Base Electrical Access • Through the Base Electrical with Circuit Breaker14,15 • Through the Base Electrical with Disconnect Switch10,14,15 Factory* or Field Installed Options17 • Barometric Relief • Clogged Filter/Fan Failure Switch4•7 • Discharge Air Sensing Kit4'7 • Economizer (Downflow)1 • Electric Heaters7'11,15 • Frostat3,4,7 • LonTalk® Communications Interface (LCI)7 • Oversized Motors7 • Reference or Comparative9'7 Enthalpy • Tool -less Hail Guards? • Trane Communications Interface (TCI)2•7 Field Installed Options • CO2 Sensing • Digital Display Zone Sensor • Dual Thermistor Remote Zone Sensor • Economizer (Horizontal) • High Altitude Kit • • • • • • • • • • • • • • High and Low Static Drive Kits 9. Humidity Sensor Low Static Drive LP Conversion Kit Manual Outside Air Damper Motorized Outside Air Dampers Powered Exhaust Quick Start Kit ReliaTel Options Module12 Remote Potentiometer Roof Curb (Downflow Only) Thermostat Ventilation Override Accessory4 Zone Sensors and Remote Zone Sensors Model Number Notes 1. Some field set up required. 2. TCI is for use with non-VariTrac systems and VariTrac systems. 3. All 10th digit model numbers including reheat coil (M,N,P,R) require additional factory installed options; ReliaTelTM options module, Frostat, and 2" pleated filters. 4. Requires ReliaTel options module. 5. Requires Economizer. 6. Must be ordered with Through - the -Base Electrical option and either Unit Mounted Disconnect or Circuit Breaker. 7. Available factory installed on downflow AND horizontal units. Verify with ordering system. 8. The Novar control option includes the following factory installed and wired devices: Novar ETM -2024 or Novar 3051 rooftop controller, fan proving switch, clogged filter or unit shutdown switch, Cool 1, Cool 2, Heat switch and discharge air sensor (downflow only). Note: Option cannot be ordered in conjunction with FIOPS Smoke Detector option. 10. This option consists of the Novar return air sensor (Novar #WTS- 10) that is wired and shipped in the return air section of the unit. The sensor ships with approximately 15' of extra wire for dropping down the return air duct (downflow only). Cannot be fused. 11. Must be factory installed when using Through -the -Base Options. 12. ReliaTel Options Module is required when ordering the following accessories: Clogged Filter Switch, Fan Fail Switch, Discharge Air Sensing Kit, Frostat, Ventilation Override, Smoke Detector and Dehumidification. 13. Optioncannotbe ordered in conjunction with field installed economizer. Must be factory installed. The return air smoke detector may not fit up or work properly on the Voyager units when used in conjunction with 3rd party accessories (such as bolt on heat wheels, economizers, and power exhaust). Do not order the return air smoke detectors when using this type of accessory. 14. Unit mounted disconnect and circuit breakers are mutually exclusive of each other. 15. Through -the -base electrical option must be ordered with either unit mounted disconnect or circuit breaker. When adding heat, must order Trane Electric Heat. 16. Available on high efficiency, downflow units only. 17. All Factory Installed Options are Built -to -Order. Check order services for estimated production cycle. Note: *Most Factory Installed Options (FIOPS) available for Downflow Air Discharge units only. Please verify with ordering system for availability. RT-PRCO24-EN 15 General Data Table 1. General Data - 121/2-15 Tons 16 RT-PRCO24-E N 12/2 Tons Downflow & Horizontal Units 15 Tons Downflow & Horizontal Units TC*150D3,4,W,K YC*150D3,4,WL/H,K TC*180B3,4,W,K YC*18083,4,WL/H,K Cooling Performance) Gross Cooling Capacity EER (Downflow/Horizontal)(ii) Nominal CFM / ARI Rated CFM ARI Net Cooling Capacity Integrated Part Load Value(iii) System Power (kW) 150,000 9.8 5,000/4,400 142,000 10.5 14.49 150,000 9.6 5,000/4,000 142,000 10.3 14.79 182,000 9.9 6,000/5,300 174,000 10.2 17.57 182.000 9.7 6,000/5,300 174,000 10.0 17.94 Compressor Number/Type 2/Scrolls 2/Scrolls 2/Scrolls 2/Scrolls Sound Outdoor Sound Rating (BELS)0') 9.2 9.2 9.2 9.2 Outdoor Coil Type Tube Size (in.) OD Face Area (sq. ft.) Rows/FPI Hi -Performance 0.375 24.18 2/16 Hi -Performance 0.375 24.18 2/16 Hi -Performance 0.375 27.12 3/16 Hi -Performance 0.375 27.12 3/16 Indoor Coil Type Tube Size (in.) Face Area (sq. ft.) Rows/FPI Refrigerant Control Drain Connection Number/Size (in.) Hi -Performance 0.375 17.50 2/15 Short Orifice 1/1.00 NPT Hi -Performance 0.375 17.50 2/15 Short Orifice 1/1.00 NPT Hi -Performance 0.375 17.50 2/15 Short Orifice 1/1.00 NPT Hi -Performance 0.375 17.50 2/15 Short Orifice 1/1.00 NPT Outdoor Fan Type Number Used/Diameter (in.) Drive Type/No. Speeds CFM Number Motors/HP Motor RPM Propeller 2/26 Direct/1 10,600 2/.50 1,100 Propeller 2/26 Direct/1 10,600 2/.50 1,100 Propeller 2/26 Direct/1 10,200 2/.50 1,100 Propeller 2/26 Direct/1 10,200 2/.50 1,100 Indoor Fan Type Number Used/Diameter (in.) Drive Type/Number Speeds Number Motors Motor HP (Standard/Oversized)(") Motor RPM (Standard/Oversized) Motor Frame Size (Standard/ Oversized) FC Centrifugal 1/15x15 Belt/1 1 3.0/5.0 1,740/3,450 145T/145T FC Centrifugal 1/15x15 Belt/1 1 3.0/5.0 1,740/3,450 145T/145T FC Centrifugal 1/15x15 Belt/1 1 3.0/5.0 1,740/3,450 145T/145T FC Centrifugal 1/15x15 Belt/1 1 3.0/5.0 1,740/3,450 145T/145T Filters Type Furnished(vi) Number Size Recommended Downflow Horizontal Throwaway (2)20x20x2,(4)20x25x2 (2)20x20x2,(4)20x25x2 Throwaway (2)20x20x2,(4)20x25x2 (2)20x20x2,(4)20x25x2 Throwaway (2)20x20x2,(4)20x25x2 (2)20x20x2,(4)20x25x2 Throwaway (2)20x20x2,(4)20x25x2 (2)20x20x2,(4)20x25x2 Refrigerant Charge Pounds of R-22(vii) 9.3/9.4 Circuit 9.3/9.4 Circuit 17.5/9.5 Circuit 17.5/9.5 Circuit 16 RT-PRCO24-E N MANE General Data (121/2,15 Tons Standard Efficiency) Table 1. (continued) General Data — 121/2-15 Tons (I) Cooling Performance is rated at 95°F ambient, 80°F entering dry bulb, 67°F entering wet bulb Gross capacity does not Include the effect of fan motor heat. ARI capacity Is net and Includes the effect of fan motor heat. Units are suitable for operation to 20% of nominal cfm. Certified In accordance with the Unitary Large Equipment Certification Program, which is based on ARI Standard 340/360-93. (°) EER is rated at ARI conditions and In accordance with ARI Standard 210/240 or 360. (I11) Integrated Part Load Value is rated in accordance with ARI Standard 210/240 or 360. Units are rated at 80°F ambient, 80°F entering dry bulb, and 67°F entering wet bulb at ARI rated cfm. (Iv) Outdoor Sound Rating shown is tested in accordance with ARI Standard 270 or 370. (v) For 380V/60Hz units, the oversized motor (Indoor Fan) is used as the standard motor. Refer to oversized motor data. (°I) An optional 2 Inch pleated fillter is also available. (vil) Refrigerant charge is an approximate value. For a more precise value, see un t nameplate and service instructions. (vin) Heating Performance limit settings and rating data were established and approved under laboratory test conditions using American National Standards Institute standards. Ratings shown are for elevations up to 2000 feet. For elevations above 2000 feet, ratings should be reduced at the rate of 4% for each 1000 feet above sea level. (lx) AFUE is rated in accordance with DOE test procedures. *Indicates both downflow/horizontal units. RT-PRCO24-EN 17 121h Tons Downflow & Horizontal Units 15 Tons Downflow & Horizontal Units Heating Performance("III) Low High Low High (Gas/Electric Only) Heating Models Heating Input (Btuh) 1st Stage (Btu) 150,000 100,000 250,000 175,000 250,000 175,000 350,000 250,000 Heating Output (Btuh) 1st Stage (Btu) 122,000 81,000 203,000 142,000 203,000 142,000 284,000 203,000 AFUE (%)(ix) Downflow/Horizontal 81.0 80.7/79.9 80.7/79.9 80.1/79.1 Steady State Efficiency% 81.0 81.0 81.0 81.0 No. Burners 1 1 No. Stages 2 2 Gas Supply Line Pressure (lin w.c.) Natural or LP (minimum/maximum) 2.5/14.0 2.5/14.0 Gas Connection Pipe Size (in.) 1/2 1/2 3/4 (I) Cooling Performance is rated at 95°F ambient, 80°F entering dry bulb, 67°F entering wet bulb Gross capacity does not Include the effect of fan motor heat. ARI capacity Is net and Includes the effect of fan motor heat. Units are suitable for operation to 20% of nominal cfm. Certified In accordance with the Unitary Large Equipment Certification Program, which is based on ARI Standard 340/360-93. (°) EER is rated at ARI conditions and In accordance with ARI Standard 210/240 or 360. (I11) Integrated Part Load Value is rated in accordance with ARI Standard 210/240 or 360. Units are rated at 80°F ambient, 80°F entering dry bulb, and 67°F entering wet bulb at ARI rated cfm. (Iv) Outdoor Sound Rating shown is tested in accordance with ARI Standard 270 or 370. (v) For 380V/60Hz units, the oversized motor (Indoor Fan) is used as the standard motor. Refer to oversized motor data. (°I) An optional 2 Inch pleated fillter is also available. (vil) Refrigerant charge is an approximate value. For a more precise value, see un t nameplate and service instructions. (vin) Heating Performance limit settings and rating data were established and approved under laboratory test conditions using American National Standards Institute standards. Ratings shown are for elevations up to 2000 feet. For elevations above 2000 feet, ratings should be reduced at the rate of 4% for each 1000 feet above sea level. (lx) AFUE is rated in accordance with DOE test procedures. *Indicates both downflow/horizontal units. RT-PRCO24-EN 17 Table 2. General Data - 171/2-20 Tons General Data (171/2, 20 Tons Standard Efficiency) 18 RT-PRCO24-EN 17'/z Tons Downflow & Horizontal Units 20 Tons Downflow & Horizontal Units TC*210C3,4,W,K YC*210C3,4,WL/H,K TC*240B3,4,W,K YC*240B3,4,WL/H,K Cooling Performance(') Gross Cooling Capacity EER (Downflow/Horizontal)0") Nominal CFM / ARI Rated CFM ARI Net Cooling Capacity Integrated Part Load Value(") System Power (kW) 210,000 9.8 7,000/5,800 196,000 10.0 20.0 210,000 9.6 7,000/5,800 196,000 9.8 20.41 242,000 9.7 8,000/7,000 232,000 10.0 23.91 242,000 9.5 8,000/7,000 232,000 9.8 24.42 Compressor Number/Type 2/Scrolls 2/Scrolls 2/Scrolls 2/Scrolls Sound Outdoor Sound Rating (BELS)('v) 9.4 9.4 9.4 9.4 Outdoor Coil Type Tube Size (in.) OD Face Area (sq. ft.) Rows/FPI Hi -Performance 0.375 27.12 3/16 Hi -Performance 0.375 27.12 3/16 Hi -Performance 0.375 35.30 3/16 Hi -Performance 0.375 35.30 3/16 Indoor Coll Type Tube Size (in.) Face Area (sq. ft.) Rows/FPI Refrigerant Control Drain Connection Number/Size (in.) Hi -Performance 0.375 17.50 4/15 Short Orifice 1/1.00 NPT Hi -Performance 0.375 17.50 4/15 Short Orifice 1/1.00 NPT Hi -Performance 0.375 26.00 2/15 Short Orifice 1/1.00 NPT Hi -Performance 0.375 26.00 2/15 Short Orifice 1/1.00 NPT Outdoor Fan Type Number Used/Diameter (in.) Drive Type/No. Speeds CFM Number Motors/HP Motor RPM Propeller 2/26 Direct/1 13,400 2/1.0 1,125 Propeller 2/26 Direct/1 13,400 2/1.0 1,125 Propeller 2/26 Direct/1 14,600 2/1.0 1,125 Propeller 2/26 Direct/1 14,600 2/1.0 1,125 Indoor Fan Type Number Used/Diameter (in.) Drive Type/Number Speeds Number Motors Motor HP (Standard/Oversized)(v) Motor RPM (Standard/Oversized) Motor Frame Size (Standard/ Oversized) FC Centrifugal 1/15x15 Belt/1 1 5.0/7.5 3,450/3,470 145T/184T FC Centrifugal 1/15x15 Belt/1 1 5.0/7.5 3,450/3,470 145T/184T FC Centrifugal 1/18x18 Belt/1 1 5.0/7.5 3,450/3,470 145T/184T FC Centrifugal 1/18x18 Belt/1 1 5.0/7.5 3,450/3,470 145T/184T Filters Type Furnished(vi) Number Size Recommended Downflow Horizontal Throwaway (2)20x20x2,(4)20x25x2 (2)20x20x2,(4)20x25x2 Throwaway (2)20x20x2,(4)20x25x2 (2)20x20x2,(4)20x25x2 Throwaway (4)20x20x2,(4)20x25x2 (8)20x25x2 Throwaway (4)20x20x2,(4)20x25x2 (8)20x25x2 Refrigerant Charge Pounds of R-22(vii) Downflow Horizontal 21.0/14.3 Circuit 21.5/14.5 Circuit 21.0/14.3 Circuit 21.0/14.5 Circuit 18.9/21.0 Circuit 18.9/21.0 Circuit 18 RT-PRCO24-EN General Data (171/2, 20 Tons Standard Efficiency) Table 2. (continued) General Data — 171/2-20 Tons (0 Cooling Performance is rated at 95°F ambient, 80°F entering dry bulb, 67°F entering wet bulb. Gross capacity does not Include the effect of fan motor heat. ARI capacity Is net and Includes the effect of fan motor heat. Units are suitable for operation to +20% of nominal cfm. Certified in accordance with the Unitary Large Equipment Certification Program, which is based on ARI Standard 340/360-93. (°) EER is rated at ARI conditions and in accordance with ARI Standard 210/240 or 360. (i°) Integrated Part Load Value is rated in accordance with ARI Standard 210/240 or 360. Units are rated at 80°F ambient, 80°F entering dry bulb, and 67°F entering wet bulb at ARI rated cfm. (iv) Outdoor Sound Rating shown is tested In accordance with ARI Standard 270 or 370. (v) For 380V/60Hz units, the oversized motor (Indoor Fan) is used as the standard motor. Refer to oversized motor data. (vi) An optional 2 inch pleated filter is also available. (vu) Refrigerant charge is an approximate value. For a more precise value, see unit nameplate and service instructions. (viii) Heating Performance limit settings and rating data were established and approved under laboratory test conditions using American National Standards Institute standards. Ratings shown are for elevations up to 2000 feet. For elevations above 2000 feet, ratings should be reduced at the rate of 4% for each 1000 feet above sea level. (ix) AFUE is rated in accordance with DOE test procedures. *Indicates both downflow/horizontal units. RT-PRCO24-EN 19 171/2 Tons Downflow & Horizontal Units 20 Tons Downflow & Horizontal Units Heating Performance(viii) Low High Low High (Gas/Electric Only) Heating Models Heating Input (Btuh) 1st Stage (Btu) 250,000 175,000 350,000 250,000 250,000 175,000 400,000 300,000 Heating Output (Btuh) 1st Stage (Btu) 203,000 142,000 284,000 203,000 203,000 142,000 324,000 243,000 AFUE (%)fix) Downflow/Horizontal 80.7/79.9 80.1/79.1 80.2/81.0 79.8/79.7 Steady State Efficiency% 81.0 81.0 81.0 81.0 No. Burners 1 1 No. Stages 2 2 Gas Supply Line Pressure (in w.c.) Natural or LP (minimum/maximum) 2.5/14.0 2.5/14.0 Gas Connection Pipe Size (in.) 1/2 3/4 1/2 3/4 (0 Cooling Performance is rated at 95°F ambient, 80°F entering dry bulb, 67°F entering wet bulb. Gross capacity does not Include the effect of fan motor heat. ARI capacity Is net and Includes the effect of fan motor heat. Units are suitable for operation to +20% of nominal cfm. Certified in accordance with the Unitary Large Equipment Certification Program, which is based on ARI Standard 340/360-93. (°) EER is rated at ARI conditions and in accordance with ARI Standard 210/240 or 360. (i°) Integrated Part Load Value is rated in accordance with ARI Standard 210/240 or 360. Units are rated at 80°F ambient, 80°F entering dry bulb, and 67°F entering wet bulb at ARI rated cfm. (iv) Outdoor Sound Rating shown is tested In accordance with ARI Standard 270 or 370. (v) For 380V/60Hz units, the oversized motor (Indoor Fan) is used as the standard motor. Refer to oversized motor data. (vi) An optional 2 inch pleated filter is also available. (vu) Refrigerant charge is an approximate value. For a more precise value, see unit nameplate and service instructions. (viii) Heating Performance limit settings and rating data were established and approved under laboratory test conditions using American National Standards Institute standards. Ratings shown are for elevations up to 2000 feet. For elevations above 2000 feet, ratings should be reduced at the rate of 4% for each 1000 feet above sea level. (ix) AFUE is rated in accordance with DOE test procedures. *Indicates both downflow/horizontal units. RT-PRCO24-EN 19 TRANE General Data (25 Tons Standard Efficiency) Table 3. General Data — 25 Tons 20 RT PRCO24-EN 25 Tons Downflow & Horizontal Units T/YC*300B3,4,W(L,H(i)),K Cooling Performance(ii) Gross Cooling Capacity EER (Downflow/Horizontal)"') Nominal CFM / ARI Rated CFM ARI Net Cooling Capacity Integrated Part Load Value(iv) System Power (kW) 290,000 9.7 10,000/8,750 272,000 9.8 28.05 Compressor Number/Type 2/Scrolls Sound Outdoor Sound Rating (BELS)(v) 9.4 Outdoor Coil Type Tube Size (in.) OD Face Area (sq. ft.) Rows/FPI Hi -Performance 0.375 36.43 2/16 Indoor Coll Type Tube Size (in.) Face Area (sq. ft.) Rows/FPI Refrigerant Control Drain Connection Number/Size (in.) Hi -Performance 0.375 26.00 3/15 Short Orifice 1/1.00 NPT Outdoor Fan Type Number Used/Diameter (in.) Drive Type/No. Speeds CFM Number Motors/HP Motor RPM Propeller 2/28 Direct/1 16,700 2/1.0 1,125 Indoor Fan Type Number Used/Diameter (in.) Drive Type/Number Speeds Number Motors Motor HP (Standard/Oversized)(vI) Motor RPM (Standard/Oversized) Motor Frame Size (Standard/Oversized) FC Centrifugal 1/18x18 Belt/1 1 7.5/N/A 3,470/N/A 184T/N/A Filters Type Furnished(vii) Number Size Recommended Downflow Horizontal Throwaway (4)20x20x2,(4)20x25x2 (8)20x25x2 Refrigerant Charge Pounds of R -22(v"') Downflow Horizontal 17.0/Circuit 20 RT PRCO24-EN General Data (25 Tons Standard Efficiency) Table 3. (continued) General Data — 25 Tons (I) Applies to Y* models only. (11) Cooling Performance is rated at 95°F ambient, 80°F entering dry bulb, 67°F entering wet bulb. Gross capacity does not include the effect of fan motor heat. ARI capacity is net and includes the effect of fan motor heat. Unfits are suitable for operation to t20% of nominal cfm. Certified in ac- cordance with the Unitary Large Equipment Certification Program, which is based on ARI Standard 340/360-93. (III) EER is rated at ARI conditions and in accordance with ARI Standard 210/240 or 360. (iv) Integrated Part Load Value is rated in accordance with ARI Standard 210/240 or 360. Units are rated at 80°F ambient, 80°F entering dry bulb, and 67°F entering wet bulb at ARI rated cfm. (v) Outdoor Sound Rating shown is tested in accordance with ARI Standard 270 or 370. (vi) For 380V/60Hz units, the oversized motor (Indoor Fan) is used as the standard motor. Refer to oversized motor data. (vii) An optional 2 inch pleated filter is also available. (VIII) Refrigerant charge is an approximate value. For a more precise value, see unit nameplate and ser- vice instructions. (Ix) Heating Performance limit settings and rating data were established and approved under labora- tory test conditions using American National Standards Institute standards. Ratings shown are for elevations up to 2000 feet. For elevations above 2000 feet, ratings should be reduced at the rate of 4% for each 1000 feet above sea level. (x) AFUE is rated In accordance with DOE test procedures. *Indicates both downflow/horizontal units. RT-PRCO24-EN 21 25 Tons Downflow & Horizontal Units Heating Performance(ix) Low High (Gas/Electric Only) Heating Models Heating Input (Btuh) 1st Stage (Btu) 250,000 175,000 400,000 300,000 Heating Output (Btuh) 1st Stage (Btu) 203,000 142,000 324,000 243,000 AFUE (%)(x) Downflow/Horizontal 80.2/81.0 79.8/79.7 Steady State Efficiency% 81.4/81.0 80.8/81.0 No. Burners 1 No. Stages 2 Gas Supply Line Pressure (in w.c.) Natural or LP (minimum/maximum) 2.5/14.0 Gas Connection Pipe Size (In.) 1/2 3/4 (I) Applies to Y* models only. (11) Cooling Performance is rated at 95°F ambient, 80°F entering dry bulb, 67°F entering wet bulb. Gross capacity does not include the effect of fan motor heat. ARI capacity is net and includes the effect of fan motor heat. Unfits are suitable for operation to t20% of nominal cfm. Certified in ac- cordance with the Unitary Large Equipment Certification Program, which is based on ARI Standard 340/360-93. (III) EER is rated at ARI conditions and in accordance with ARI Standard 210/240 or 360. (iv) Integrated Part Load Value is rated in accordance with ARI Standard 210/240 or 360. Units are rated at 80°F ambient, 80°F entering dry bulb, and 67°F entering wet bulb at ARI rated cfm. (v) Outdoor Sound Rating shown is tested in accordance with ARI Standard 270 or 370. (vi) For 380V/60Hz units, the oversized motor (Indoor Fan) is used as the standard motor. Refer to oversized motor data. (vii) An optional 2 inch pleated filter is also available. (VIII) Refrigerant charge is an approximate value. For a more precise value, see unit nameplate and ser- vice instructions. (Ix) Heating Performance limit settings and rating data were established and approved under labora- tory test conditions using American National Standards Institute standards. Ratings shown are for elevations up to 2000 feet. For elevations above 2000 feet, ratings should be reduced at the rate of 4% for each 1000 feet above sea level. (x) AFUE is rated In accordance with DOE test procedures. *Indicates both downflow/horizontal units. RT-PRCO24-EN 21 Table 4. General Data — 121/2-15 Tons General Data (121/2,15 Tans High Efficiency) 22 RT-PRCO24-EN 12'/2 Tons Downflow & Horizontal Units 15 Tons Downflow & Horizontal Units T/YC*151C3,4,W(i) T/YC*181C3,4,W(11) Cooling Performance(iii) Gross Cooling Capacity EER0v) Nominal CFM / ARI Rated CFM ARI Net Cooling Capacity Integrated Part Load Value(') System Power (kW) 154,000 11.30 5,000/4,400 146,000 11.5 12.92 189,000 11.50 6,000/5,300 180,000 13.3 15.65 Compressor Number/Type 2/Scrolls 2/Scrolls Sound Outdoor Sound Rating (BELS)(Vi) 9.2 9.2 Outdoor Coil Type Tube Size (in.) OD Face Area (sq. ft.) Rows/FPI Hi -Performance 0.375 27.12 2/16 Hi -Performance 0.375 35.30 3/16 Indoor Coil Type Tube Size (in.) Face Area (sq. ft.) Rows/FPI Refrigerant Control Drain Connection Number/Size (in.) Hi -Performance 0.375 17.50 3/15 Short Orifice 1/1.00 NPT Hi -Performance 0.375 26.00 3/15 Short Orifice 1/1.00 NPT Outdoor Fan Type Number Used/Diameter (in.) Drive Type/No. Speeds CFM Number Motors/HP Motor RPM Propeller 2/26 Direct/1 10,400 2/.50 1,100 Propeller 2/26 Direct/1 11,000 2/.50 1,100 Indoor Fan Type Number Used/Diameter (in.) Drive Type/Number Speeds Number Motors Motor HP (Standard/Oversized)(vii) Motor RPM (Standard/Oversized) Motor Frame Size (Standard/Oversized) FC Centrifugal 1/15x15 Belt/1 1 3.0/5.0 1,740/3,450 145T/145T FC Centrifugal 1/18x18 IBeIt/1 1 3.0/5.0 1,740/3,450 145T/145T Filters Type Furnished(viii) Number Size Recommended Downflow Horizontal Throwaway (2)20x20x2,(4)20x25x2 (2)20x20x2,(4)20x25x2 Throwaway (4)20x20x2,(4)20x25x2 (8)20x25x2 Optional Hot Gas Reheat Coil Type Tube Size (in.) OD Face Area (sq. ft) Rows/FPI Hi -Performance 0.375 17.5 1/16 Hi -Performance 0.375 26 1/16 Refrigerant Charge Pounds of R -220X) Standard Optional Hot Gas Reheat Coil 15.0/13.8 15.3/14.3 25.0/13.0 27.8/11.4 22 RT-PRCO24-EN 9 TRAM. General Data (121/2,15 Tons High Efficiency) Table 4. (continued) General Data — 121-15 Tons 0) TXV/Face-Split Option (Downflow Only) YCD151C3,4,W (EER):11.3; (System Power kW): 12.92; (Refrigerant Control): Expansion Valve; (Refrig- erant Charge): 13.4/12.0. 01) TXV/Face-Split Option (Downflow Only) YCD181C3,4,W (EER):11.4; (System Power kW): 15.79; (Refrigerant Control): Expansion Valve; (Refrig- erant Charge): 26.0/12.0. (111) Cooling Performance is rated at 95°F ambient, 80°F entering dry bulb, 67°F entering wet bulb. Gross capacity does not include the effect of fan motor heat. ARI capacity Is net and includes the effect of fan motor heat. Units are suitable for operation to ±20% of nominal cfm. Certified in accordance with the Unitary Large Equipment Certification Program, which is based on ARI Standard 340/360-93. Ilv) EER is rated at ARI conditions and in accordance with ARI Standard 210/240 or 360. (v) Integrated Part Load Value is rated in accordance with ARI Standard 210/240 or 360. Units are rated at 80°F ambient, 80°F entering dry bulb, and 67°F entering wet bulb at ARI rated cfm. (vi) Outdoor Sound Rating shown is tested in accordance with ARI Standard 270 or 370. (vil) For 380V/60Hz units, the oversized motor (Indoor Fan) is used as the standard motor. Refer to oversized motor data. (' ')An optional 2 inch pleated filter is also available. Ox) Refrigerant charge is an approximate value. For a more precise value, see unit nameplate and service instructions.. (x) Heating Performance limit settings and rating data were established and approved under laboratory test conditions using American National Stan- dards Institute standards. Ratings shown are for elevations up to 2000 feet. For elevations above 2000 feet, ratings should be reduced at the rate of 4% for each 1000 feet above sea level. (xi) AFUE Is rated In accordance with DOE test procedures. RT-PRCO24-EN 23 121 Tons Downflow & Horizontal Units 15 Tons Downflow & Horizontal Units Heating Performance(x) Low High Low High (Gas/Electric Only) Heating Models Heating Input (Btuh) 1st Stage (Btu) 150,000 100,000 250,000 175,000 250,000 175,000 350,000 250,000 Heating Output (Btuh) 1st Stage (Btu) 122,000 81,000 203,000 142,000 203,000 142,000 284,000 203,000 AFUE%(xi) Downflow/Horizontal 81.0/81.0 80.7/79.9 80.7/79.9 80.1/79.1 Steady State Efficiency% 81.0 81.0 81.0 81.0 No. Burners 1 1 1 1 No. Stages 2 2 2 2 Gas Supply Line Pressure (in w.c.) Natural or LP (minimum/maximum) 2.5/14.0 2.5/14.0 Gas Connection Pipe Size Qin.) 1/2 1/2 1/2 3/4 0) TXV/Face-Split Option (Downflow Only) YCD151C3,4,W (EER):11.3; (System Power kW): 12.92; (Refrigerant Control): Expansion Valve; (Refrig- erant Charge): 13.4/12.0. 01) TXV/Face-Split Option (Downflow Only) YCD181C3,4,W (EER):11.4; (System Power kW): 15.79; (Refrigerant Control): Expansion Valve; (Refrig- erant Charge): 26.0/12.0. (111) Cooling Performance is rated at 95°F ambient, 80°F entering dry bulb, 67°F entering wet bulb. Gross capacity does not include the effect of fan motor heat. ARI capacity Is net and includes the effect of fan motor heat. Units are suitable for operation to ±20% of nominal cfm. Certified in accordance with the Unitary Large Equipment Certification Program, which is based on ARI Standard 340/360-93. Ilv) EER is rated at ARI conditions and in accordance with ARI Standard 210/240 or 360. (v) Integrated Part Load Value is rated in accordance with ARI Standard 210/240 or 360. Units are rated at 80°F ambient, 80°F entering dry bulb, and 67°F entering wet bulb at ARI rated cfm. (vi) Outdoor Sound Rating shown is tested in accordance with ARI Standard 270 or 370. (vil) For 380V/60Hz units, the oversized motor (Indoor Fan) is used as the standard motor. Refer to oversized motor data. (' ')An optional 2 inch pleated filter is also available. Ox) Refrigerant charge is an approximate value. For a more precise value, see unit nameplate and service instructions.. (x) Heating Performance limit settings and rating data were established and approved under laboratory test conditions using American National Stan- dards Institute standards. Ratings shown are for elevations up to 2000 feet. For elevations above 2000 feet, ratings should be reduced at the rate of 4% for each 1000 feet above sea level. (xi) AFUE Is rated In accordance with DOE test procedures. RT-PRCO24-EN 23 TRAM" Table 5. General Data — 171, 20, 25 Tons General Data (171/2, 20, 25 Tons High Efficiency) 24 RT-PRCO24-EN 171/2 Tons Downflow & Horizontal Units 20 Tons Downflow & Horizontal Units 25 Tons Downflow & Horizontal Units T/YC*211C3,4,W T/YC*241C3,4,W(i) T/YC*301C3,4,W Cooling Performance(°) Gross Cooling Capacity EER(") Nominal CFM / ARI Rated CFM ARI Net Cooling Capacity.208,000 Integrated Part Load Value(") System Power (kW) 220,000 11.0 7,000/6,200 12.0 18.91 268,000 10.6 8,000/7,000 250,000 11.2 23.58 300,000 10.4 10,000/8,750 278,000 11.0 26.73 Compressor Number/Type 2/Scrolls 2/Scrolls 2/Scrolls Sound Outdoor Sound Rating (BELS)(") 9.4 9.4 9.4 Outdoor Coil Type Tube Size (in.) OD Face Area (sq. ft.) Rows/FPI Hi -Performance 0.375 35.30 3/16 Hi -Performance 0.375 35.30 3/16 Hi -Performance 0.375 35.30 3/16 Indoor Coil Type Tube Size (in.) Face Area (sq. ft.) Rows/FPI Refrigerant Control Drain Connection Number/Size (in.) Hi -Performance 0.375 26.00 4/15 Short Orifice 1/1.0 NPT Hi -Performance 0.375 26.00 40,0/15 Short Orifice 1/1.0 NPT Hi -Performance 0.375 26.00 4/15 Short Orifice 1/1.0 NPT Outdoor Fan Type Number Used/Diameter (in.) Drive Type/No. Speeds CFM Number Motors/HP Motor RPM Propeller 2/26 Direct/1 12,800 2/1.0 1,125 Propeller 2/26 Direct/1 13,700 2/1.0 1,125 Propeller 2/26 Direct/1 13,700 2/1.0 1,125 Indoor Fan Type Number Used/Diameter (in.) Drive Type/Number Speeds Number Motors Motor HP (Standard/Oversized) Motor RPM (Standard/Oversized) Motor Frame Size (Standard/Oversized) FC Centrifugal 1/18x18 Belt/1 1 5.0/7.5 3,450/3,470 145T/184T FC Centrifugal 1/18x18 Belt/1 1 5.0/7.5 3,450/3,470 145T/184T FC Centrifugal 1/18x18 Belt/1 1 7.5 3,470 184T Filters Type Furnished("") Number Size Recommended Downflow Horizontal Throwaway (4)20x20x2,(4)20x25x2 (8)20x25x2 Throwaway (4)20x20x2,(4)20x25x2 (8)20x25x2 Throwaway (4)20x20x2,(4)20x25x2 (8)20x25x2 Optional Hot Gas Reheat Coil Type Tube Size (in.) OD Face Area (sq. ft) Rows/FPI — — — — Hi -Performance 0.375 26 1/16 — — — — Refrigerant Charge Pounds of R-22(viii) Standard Optional Hot Gas Reheat Coil 25.7/12.5 — 21.8/21.8 21.3/21.0 24.5/24.5 — 24 RT-PRCO24-EN e TRAM" General Data (171/2, 20, 25 Tons High Efficiency) Table 5. (continued) General Data — 17'/2, 20, 25 Tons (0 TXV/Face-Split Option (Downflow Only) YCD241C3,4,W (Gross Cooling Capac ty):259,000; (ARI Net Cooling Capacity): 244,000; (System Power kW): 23.02; (Refrigerant Control): Expansion Valve; (Refrigerant Charge): 21.5/22„2 00 Cooling Performance Is rated at 95°F ambient, 80°F entering dry bulb, 67°F entering wet bulb. Gross capacity does not include the effect of fan motor heat. ARI capacity is net and Includes the effect of fan motor heat. Units are suitable for operation to ±20% of nominal cfm. Certified in accordance with the Unitary Large Equipment Certification Program, which is based on ARI Standard 340/360-93. ('Ii) EER is rated at ARI conditions and in accordance with ARI Standard 210/240 or 360. (Iv) Integrated Part Load Value is rated in accordance with ARI Standard 210/240 or 360. Units are rated at 80°F ambient, 80°F entering dry bulb, and 67°F entering wet bulb at ARI rated cfm. (v) Outdoor Sound Rating shown is tested in accordance with ARI Standard 270 or 370. (vi) On Hot Gas Reheat units, Indoor Coil = 3 rows. (vii) An optional 2 inch pleated filter is also available. (viii)Refrigerant charge is an approximate value. For a more precise value, see unit nameplate and service instructions. (ix) Heating Performance limit settings and rating data were established and approved under laboratory test conditions using American National Standards Institute standards. Ratings shown are for elevations up to 2000 feet. For elevations above 2000 feet, ratings should be reduced at the rate of 4% for each 1000 feet above sea level. (x) AFUE is rated in accordance with DOE test procedures. *Indicates both downflow/horizontal units. RT-PRCO24-EN 25 171 Tons Downflow & Horizontal Units 20 Tons Downflow & Horizontal Units 25 Tons Downflow & Horizontal Units Heating Performance(Ix) Low High Low High Low High (Gas/Electric Only) Heating Models Heating Input (Btuh) 1st Stage (Btu) 250,000 175,000 350,000 250,000 250,000 175,000 400,000 300,000 250,000 175,000 400,000 300,000 Heating Output (Btuh) 1st Stage (Btu) 203,000 142,000 284,000 203,000 203,000 142,000 324,000 243,000 203,000 142,000 324.000 243,000 AFUE%(x) Downflow/Horizontal 80.2/81.0 79.3/79.7 80.2/81.0 79.8/79.7 80.2/81.0 79.8/79.7 Steady State Efficiency% 81.0 81.0 81.0 81.0 81.0 81.0 No. Burners 1 1 1 1 1 1 No. Stages 2 2 2 2 2 2 Gas Supply Line Pressure (In w.c.) Natural or LP (minimum/maximum) 2.5/14.0 2.5/14.0 2.5/14.0 Gas Connection Pipe Size (in.) 1/2 3/4 1/2 3/4 1/2 3/4 (0 TXV/Face-Split Option (Downflow Only) YCD241C3,4,W (Gross Cooling Capac ty):259,000; (ARI Net Cooling Capacity): 244,000; (System Power kW): 23.02; (Refrigerant Control): Expansion Valve; (Refrigerant Charge): 21.5/22„2 00 Cooling Performance Is rated at 95°F ambient, 80°F entering dry bulb, 67°F entering wet bulb. Gross capacity does not include the effect of fan motor heat. ARI capacity is net and Includes the effect of fan motor heat. Units are suitable for operation to ±20% of nominal cfm. Certified in accordance with the Unitary Large Equipment Certification Program, which is based on ARI Standard 340/360-93. ('Ii) EER is rated at ARI conditions and in accordance with ARI Standard 210/240 or 360. (Iv) Integrated Part Load Value is rated in accordance with ARI Standard 210/240 or 360. Units are rated at 80°F ambient, 80°F entering dry bulb, and 67°F entering wet bulb at ARI rated cfm. (v) Outdoor Sound Rating shown is tested in accordance with ARI Standard 270 or 370. (vi) On Hot Gas Reheat units, Indoor Coil = 3 rows. (vii) An optional 2 inch pleated filter is also available. (viii)Refrigerant charge is an approximate value. For a more precise value, see unit nameplate and service instructions. (ix) Heating Performance limit settings and rating data were established and approved under laboratory test conditions using American National Standards Institute standards. Ratings shown are for elevations up to 2000 feet. For elevations above 2000 feet, ratings should be reduced at the rate of 4% for each 1000 feet above sea level. (x) AFUE is rated in accordance with DOE test procedures. *Indicates both downflow/horizontal units. RT-PRCO24-EN 25 s ' 0 TRAM° Electrical Data Table 60. Unit Wiring with Gas Heat or Cooling (No Electric Heat) Standard Indoor Fan Motor Oversize Indoor Fan Motor Maximum Fuse Maximum Fuse Unit Model Unit Operating Minimum Circuit Size or Maximum Minimum Circuit Size or Maximum Tons Number Voltage Range Ampacity(i) Circuit Breaker Ampacity Circuit Breaker 121/2 T/YC*150D3 187-253 63 80 69 80 T/YC*150D4 414-506 33 40 36 40 T/YC*150DW 518-633 26 30 28 35 T/YC*15ODK 342-418 43 50 — — 15 T/YC*180B3 187-253 78 90 84 100 T/YC*180B4 414-506 39 50 42 50 T/YC*180BW 517-633 31 40 33 40 T/YC*18OBK 342-418 50 60 — — 17'/2 T/YC*210C3 187-253 88 100 96 125 T/YC*210C4 414-506 44 50 47 60 T/YC*210CW 517-633 35 45 38 45 T/YC*210CK 342-418 57 70 — — 20 T/YC*240B3 187-253 100 125 107 125 T/YC*240B4 414-506 50 60 54 60 T/YC*240BW 517-633 40 45 43 50 T/YC*240BK 342-418 65 80 — — 25 T/YC*30083 187-253 118 150 T/YC*300B4 414-506 58 70 T/YC*300BW 517-633 46 50 T/YC*300BK 342-418 70 80 (1) For Standard and Oversized Indoor Fan Motor, values do not include power exhaust accessory. * Indicates both downflow and horizontal units. 74 RT-PRCO24-EN .0 TRAM' Electrical Data (Standard Efficiency) Table 61. Unit Wiring with Electric Heat (Single Point Connection) - Standard and Oversized Motor Downflow & Horizontal Standard Indoor Motor Oversize Indoor Motor Max Fuse Size Max Fuse Size Unit Model Heater Model Heater kW Control or Max Circuit or Max Circuit Tons Number Number Rating(') Stages MCA Breaker MCA Breaker 208/230 Volts Three Phase 121/2 TC*150D3 AYDHTRF318A/AYHHTRN318A 13.5/18.0 1 63/68 80/80 69/76 80/80 AYDHTRF336A/AYHHTRN336A 27.0/36.0 2 108/122 110/125 115/130 125/150 AYDHTRF354A/AYHHRTN354A 40.5/54.0 2 154/176 175/200 162/184 175/200 15 TC*180B3 AYDHTRK318A/AYHHTRN318A 13.5/18.0 1 78/78 100/100 84/84 100/100 AYDHTRK336A/AYHHTRN336A 27.0/36.0 2 108/122 110/125 115/130 125/150 AYDHTRK354A/AYHHTRN354A 40.5/54.0 2 154/176 175/200 162/184 175/200 171/2 TC*210C3 AYDHTRL336A/AYHHTRQ336A 27.0/36.0 2 115/130 125/150 125/139 125/150 AYDHTRL354A/AYHHTRQ354A 40.5/54.0 2 162/184 175/200 171/193 175/200 20 TC*240B3 AYDHTRL336A/AYHHTRN336A 27.0/36.0 2 115/130 125/150 125/139 125/150 AYDHTRL354A/AYHHTRN354A 40.5/54.0 2 162/184 175/200 171/193 175/200 AYDHTRK372A/AYHHTRN372A 54.0/72.0 2 209/238 225/250 218/247 225/250 25 TC*30083 AYDHTRL336A/AYHHTRN336A 27.0/36.0 2 125/139 150/150 AYDHTRL354A/AYHHTRN354A 40.5/54.0 2 171/193 175/200 AYDHTRK372A/AYHHTRN372A 54.0/72.0 2 218/247 225/250 460 Volts Three Phase 12' TC*150D4 AYDHTRL418A/AYHHTRN418A 18.0 1 34 40 37 40 AYDHTRK436A/AYHHTRN436A 36.0 2 61 70 64 70 AYDHTRK454A/AYHHTRP454A 54.0 2 88 90 91 100 15 TC*180B4 AYDHTRL418A.AYHHTRN418A 18.0 1 393 50 42 50 AYDHTRK436A/AYHHTRP436A 36.0 2 61 70 64 70 AYDHTRK454A/AYHHTRP454A 54.0 2 88 90 91 100 171 TC*210C4 AYDHTRL436A/AYHHTRQ436A 36.0 2 64 70 68 70 AYDHTRL454A/AYHHTRQ454A 54.0 2 91 100 95 100 20 TC*240B4 AYDHTRL436A/AYHHTRN436A 36.0 2 64 70 68 70 AYDHTRL454A/AYHHTRN454A 54.0 2 91 100 95 100 AYDHTRK472A/AYHHTRN472A 72.0 2 118 125 123 125 25 TC*300B4 AYDHTRL436A/AYHHTRN436A 36.0 2 68 70 AYDHTRL454A/AYHHTRN454A 54.0 2 95 100 AYDHTRK472A/AYHHTRN472A 72.0 2 123 125 575 Volts Three Phase 121/2 TC*150DW AYDHTRKW18A/AYHHTRNW18A 18.0 1 27 30 30 35 AYDHTRMW36A/AYHHTRPW36A 36.0 2 49 50 51 60 AYDHTRKW54A/AYHHTRPW54A 54.0 2 70 70 73 80 15 TC*180BW AYDHTRKW18A/AYHHTRNW18A 18.0 1 31 40 33 40 AYDHTRMW36A/AYHHTRPW36A 36.0 2 49 50 51 60 AYDHTRKW54A/AYHHTRPW54A 54.0 2 70 70 73 80 171/2 TC*210CW AYDHTRMW36A/AYHHTRPW36A 36.0 2 51 60 55 60 AYDHTRLW54A/AYHHTRQW54A 54.0 2 73 80 77 80 20 TC*240BW AYDHTRMW36A/AYHHTRMW36A 36.0 2 51 60 55 60 AYDHTRLW54A/AYHHTRNW54A 54.0 2 73 80 77 80 AYDHTRKW72A/AYHHTRNW72A 72.0 2 95 100 98 100 25 TC*300BW AYDHTRMW36A/AYHHTRMW36A 36.0 2 55 60 AYDHTRLW54A/AYHHTRNW54A 54.0 2 77 80 AYDHTRKW72A/AYHHTRNW72A 72.0 2 98 100 RT-PRCO24-EN 75 TRANS' Electrical Data (Standard Efficiency) Table 61. (continued) Unit Wiring with Electric Heat (Single Point Connection) - Standard and Oversized Motor, Downflow & Horizontal Standard Indoor Motor Oversize Indoor Motor Max Fuse Size Max Fuse Size Unit Model Heater Model Heater kW Control or Max Circuit or Max Circuit Tons Number Number Rating Stages MCA Breaker MCA Breaker 380 Volts Three Phase 121 TC*150DK AYDHTRL418A/AYHHTRL418A 11.3 1 43 50 AYDHTRK436A/AYHHTRK436A 22.6 2 55 60 AYDHTRK454AAYHHTRK454A 33.8 2 76 80 15 TC*180BK AYDHTRL418A/AYHHTRL418A 11.3 1 50 60 AYDHTRK436A/AYHHTRK436A 22.6 2 55 60 AYDHTRK454A/AYHHTRK454A 33.8 2 76 80 17'/2 TC*21OCK AYDHTRL436A/AYHHTRL436A 22.6 2 60 70 AYDHTRL454A/AYHHTRL454A 33.8 2 81 90 20 TC*2408K AYDHTRL436A/AYDHTRL436A 22.6 2 65 80 AYDHTRL454A/AYDHTRL454A 33.8 2 81 90 AYDHTRK472A/AYDHTRK472A 45.1 2 103 110 25 TC*300BK AYDHTRL436A/AYDHTRL436A 22.6 2 70 80 AYDHTRL454A/AYDHTRL454A 33.8 2 81 90 AYDHTRK472A/AYDHTRK472A 45.1 2 103 100 (0) Heater kW ratings are at 380V for 380 unit. * Indicates both downflow and horizontal units. Table 62. Electrical Characteristics - Compressor Motor and Condenser Motor - 60 Cycle Unit Model Compressor Motors Condenser Fan Motors Amps(') Amps Tons Number No. Volts Phase HP00 RPM RLA LRA No. Phase HP FLA LRA 121 T/YC*150D3 2 208-230 3 6.00 3450 20.4 156 2 1 .50 3.2 8.8 T/YC*150D4 2 460 3 6.00 3450 10.8 75 2 1 .50 1.6 3.8 T/YC*150DW 2 575 3 6.00 3450 8.3 54 2 1 .50 1.3 3.2 T/YC*150DK 2 380 3 6.0 3450 13.1 70 2 1 .50 1.9 5.2 15 T/YC*180B3 2 208-230 3 9.30/5.10 3450 31.9/20.7 253/128 2 1 .50 3.2 8.8 T/YC*18084 2 460 3 9.30/5.10 3450 16.3/10.0 113/63 2 1 .50 1.6 3.8 T/YC*1808W 2 575 3 9.30/5.10 3450 13.1/7.4 85/49 2 1 .50 1.3 3.2 T/YC*180BK 2 380 3 9.3/5.1 3450 19.7/12.1 125/64 2 1 .50 1.9 5.2 171/2 T/YC*210C3 2 208-230 3 9.3/6.0 3450 31.5/20.8 253/156 2 1 1.00 5.5 18.3 T/YC*210C4 2 460 3 9.3/6.0 3450 15.9/10.0 113/75 2 1 1.00 2.9 9.3 T/YC*210CW 2 575 3 9.3/6.0 3450 12.8/8.2 85/54 2 1 1.00 2.0 5.7 T/YC*21OCK 2 380 3 9.3/6.0 3450 19.2/12.1 125/70 2 1. 1.00 3.5 8.5 20 T/YC*240B3 2 208-230 3 9.30 3450 31.7 253 2 I 1.00 5.5 18.3 T/YC*240B4 2 460 3 9.30 3450 16.2 113 2 I 1.00 2.9 9.3 T/YC*240BW 2 575 3 9.30 3450 13.0 85 2 1 1.00 2.0 5.7 T/YC*240BK 2 380 3 9.3 3450 19.6 125 2 1 1.00 3.5 8.5 25 T/YC*300B3 2 208-230 3 10.00 3450 36.6 278 2 1 1.00 5.5 18.3 T/YC*300B4 2 460 3 10.00 3450 17.9 124 2 I 1.00 2.9 9.3 T/YC*300BW 2 575 3 10.00 3450 14.9 92 2 1 1.00 2.0 5.7 T/YC*300BK 2 380 3 10.0 3450 21.7 137 2 1 1.00 3.5 8.5 (1) For Compressor Motor and Condenser Fan Motors: Amp draw for each motor; multiply value by number of motors to determine total amps. (") HP for each compressor. 76 RT-PRCO24-EN .0 TRNVE° Electrical Data (Standard Efficiency) Table 63. Electrical Characteristics - Evaporator Fan Motor - 60 Cycle - Standard and Oversized Motor Standard Evaporator Fan Motor Oversized Evaporator Fan Motor Amps Amps Unit Model Tons Number No. Volts Phase HP FLA LRA No. Volts Phase HP FLA LRA 12'/2 T/YC*150D3 1 208-230 3 3.00 10.6 81.0 1 208-230 3 5.00 16.7 109.8 T/YC*150D4 1 460 3 3.00 4.8 40.5 1 460 3 5.00 7.6 54.9 T/YC*150DW 1 575 3 3.00 3.9 31.0 1 575 3 5.00 6.1 41.6 T/YC*150DK 1 380 3 5.0 9.2 66.5 - - - - - - 15 T/YC*18083 1 208-230 3 3.00 10.6 81.0 1 208-230 3 5.00 16.7 109.8 T/YC*18084 1 460 3 3.00 4.8 40.5 1 460 3 5.00 7.6 54.9 T/YC*180BW 1 575 3 3.00 3.9 31.0 1 575 3 5.00 6.1 41.6 T/YC*180BK 1 380 3 5.0 9.2 66.5 - - - - - - 171/2 T/YC*210C3 1 208-230 3 5.00 16.7 109.8 1 208-230 3 7.50 24.2 120.4 T/YC*210C4 1 460 3 5.00 7.6 54.9 1 460 3 7.50 11.0 74.0 T/YC*210CW 1 575 3 5.00 6.1 41.6 1 575 3 7.50 9.0 60.0 T/YC*21OCK 1 380 3 7.5 13.3 83.5 - - - - - - 20 T/YC*240B3 1 208-230 3 5.00 16.7 109.8 1 208-230 3 7.50 24.2 120.4 T/YC*240B4 1 460 3 5.00 7.6 54.9 1 460 3 7.50 11.0 74.0 T/YC*240BW 1 575 3 5.00 6.1 41.6 1 575 3 7.50 9.0 60.0 T/YC*240BK 1 380 3 7.5 13.3 83.5 - - - - - - 25 T/YC*300B3 1 208-230 3 7.50 24.2 120.4 T/YC*300B4 1 460 3 7.50 11.0 74.0 - - - - - - T/YC* 300BW 1 575 3 7.50 9.0 60.0 - - - - - - T/YC*300BK 1 380 3 7.5 13.3 83.5 - - - - - - * Indicates both downflow and horizontal units. Table 64. Electrical Characteristics - Combustion Blower Motor (Gas/Electric) Amps Unit Model Heat Heating HP RPM(0) Volts Phase FLA LRA Number Stages YC*150 Low 2 1/20 3500/2800 208-230 1 0.5 0.78 YC*180, 210, 240-300 Low 2 1/10 3500/2800 208-230 1 0.8 2.00 0'i High/Low Speed. * Indicates both downflow and horizontal units. Table 65. Electrical Characteristics - Power Exhaust (Cooling and Gas/Electric) Amps Tons Volts Phase HP RPM FLA LRA 12'/2-25 208-230 1 3/4 1040 6.6 13.5 121/2-25 460 1 3/4 1040 3.2 8.4 121/2-25 575 1 3/4 1040 2.1 5.2 RT-PRCO24-EN 77 9 TRANE` Electrical Data (High Efficiency) Table 66. Unit Wiring with Cooling (No Electric Heat) or Gas Heat — Standard Refrigeration System Standard Indoor Fan Motor Oversize Indoor Fan Motor Maximum Fuse Maximum Fuse Unit Model Unit Operating Minimum Circuit Size or Maximum Minimum Circuit Size or Maximum Tons Number Voltage Range Ampacity0) Circuit Breaker Ampacity Circuit Breaker 12'/2 T/YC*151C3 187-253 64 80 70 90 T/YC*151C4 414-506 31 40 34 40 T/YC*151CW 517-633 25 30 28 35 15 T/YC*181C3 187-253 74 90 80 100 T/YC*181C4 414-506 36 50 38 50 T/YC*181CW 517-633 29 40 31 40 171/2 T/YC*211C3 187-253 91 110 98 125 T/YC*211C4 414-506 44 60 48 60 T/YC*211CW 517-633 35 45 38 50 20 T/YC*241C3 187-253 99 125 107 125 T/YC*241C4 414-506 50 60 54 60 T/YC*241CW 517-633 40 50 43 50 25 T/YC*301C3 187-253 120 150 N/A N/A T/YC*301C4 414-506 58 70 N/A N/A T/YC*301CW 517-633 47 60 N/A N/A 0) For Standard and Oversized Indoor Fan Motor, values do not include power exhaust accessory. * Indicates both downflow and horizontal units. Table 67. Unit Wiring with Cooling (No Electric Heat) or Gas Heat — TXV/Face-Split Evaporator Coil (Downflow Only) Standard Indoor Fan Motor Oversize Indoor Fan Motor Maximum Fuse Size or Maximum Fuse Size or Unit Model Unit Operating Minimum Circuit Maximum Circuit Minimum Circuit Maximum Circuit Tons Number Voltage Range Ampadtytit Breaker Ampacity Breaker 121/2 T/YCD151C3 187-253 59 70 65 80 T/YCD151C4 414-506 30 35 32 40 T/YCD151CW 517-633 24 30 26 30 15 T/YCD181C3 :L87-253 74 90 80 90 T/YCD181C4 414-506 37 50 39 50 T/YCD181CW 517-633 30 40 32 40 171/2 T/YCD211C3 L87-253 91 125 99 125 T/YCD211C4 414-506 45 60 49 60 T/YCD211CW 517-633 36 45 39 50 20 T/YCD241C3 187-253 99 125 107 125 T/YCD241C4 414-506 51 60 54 60 T/YCD241CW 517-633 40 50 43 50 25 T/YCD301C3 187-253 117 150 N/A N/A T/YCD301C4 414-506 57 70 N/A N/A T/YCD301CW 517-633 46 50 N/A N/A 0) For Standard and Oversized Indoor Fan Motor, values do not include power exhaust accessory. Table 68. Unit Wiring with Cooling (No Electric Heat) or Gas Heat — Dehumidification (Hot Gas Reheat) Option (Downflow Only) Unit Model Tons Number Unit Operating Voltage Range Standard Indoor Fan Motor Oversize Indoor Fan Motor Maximum Fuse Size or Maximum Fuse Size or Minimum Circuit Maximum Circuit Minimum Circuit 'Maximum Circuit Ampacity0) Breaker Ampacity Breaker 12'/2 T/YCD151C3 187-253 59 70 65 80 T/YCD151C4 414-506 30 35 32 40 T/YCD151CW 517-633 24 30 26 30 15 T/YCD181C3 187-253 71 90 77 100 T/YCD181C4 414-506 36 45 39 50 T/YCD181CW 517-633 28 35 30 40 20 T/YCD241C3 187-253 98 125 105 125 T/YCD241C4 414-506 50 60 53 60 T/YCD241CW 517-633 39 50 42 50 0) For Standard and Oversized Indoor Fan Motor, values do not include power exhaust accessory. 78 RT-PRCO24-E N • TRINE` Electrical Data (High Efficiency) Table 69. Unit Wiring with Electric Heat (Single Point Connection) - Standard Refrigeration System (Downflow and Horizontal) Standard Indoor Motor Oversize Indoor Motor Max Fuse Size Max Fuse Size Unit Model Heater Model Heater kW Control or Max Circuit or Max Circuit Tons Number Number Rating Stages MCA Breaker MCA Breaker -0) 208/230 Volts Three Phase 121/2 TC*151C3 AYDHTRK318A/AYHHTRN318A 13.5/18.0 1 64/68 80/80 70/76 90/90 AYDHTRK336A/AYHHTRP336A 27.0/36.0 2 108/122 110/125 115/130 125/150 AYDHTRK354A/AYHHTRP354A 40.5/54.0 2 154/176 175/200 162/184 175/200 15 TC*181C3 AYDHTRK318A/AYHHTRM318A 13.5/18.0 1 74/74 100/100 80/80 100/100 AYDHTRK336A/AYHHTRM336A 27.0/36.0 2 108/122 110/125 115/130 125/150 AYDHTRK354A/AYHHTRM354A 40.5/54.0 2 154/176 175/200 162/184 175/200 171 TC*211C3 AYDHTRL336A/AYHHTRN336A 27.0/36.0 2 115/130 125/150 125/139 125/150 AYDHTRL354A/AYHHTRN354A 40.5/54.0 2 162/184 175/200 171/193 175/200 AYDHTRK372A/AYHHTRN372A 54.0/72.0 2 209/238 225/250 218/247 225/250 20 TC*241C3 AYDHTRL336A/AYHHTRN336A 27.0/36.0 2 115/130 125/150 125/139 125/150 AYDHTRL354A/AYHHTRN354A 40.5/54.0 2 162/184 175/200 171/193 175/200 AYDHTRK372A/AYHHTRN372A 54.0/72.0 2 209/238 225/250 218/247 225/250 25 TC*301C3 AYDHTRL336A/AYHHTRN336A 27.0/36.0 2 125/139 150/150 - - AYDHTRL354A/AYHHTRN354A 40.5/54.0 2 171/193 175/200 - - AYDHTRK372A/AYHHTRN372A 54.0/72.0 2 218/247 225/250 - - 460 Volts Three Phase 121 TC*151C4 AYDHTRL418A/AYHHTRN418A 18.0 1 34 40 37 40 AYDHTRK436A/AYHHTRP436A 36.0 2 61 70 64 70 AYDHTRK454A/AYHHTRP454A 54.0 2 88 90 91 100 15 TC*181C4 AYDHTRL418A/AYHHTRM418A 18.0 1 36 50 38 50 TCD181C4 AYDHTRK427A 27.0 2 47 50 TC*181C4 AYDHTRK436A/AYHHTRM436A 36.0 2 61 70 64 70 AYDHTRK454A/AYHHTRM454A 54.0 2 88 90 91 100 171/2 TCD211C4 AYDHTRL427A 27.0 2 51 60 TC*211C4 AYDHTRL436A/AYHHTRN436A 36.0 2 64 70 68 70 AYDHTRL454A/AYHHTRN454A 54.0 2 91 100 95 100 AYDHTRK472A/AYHHTRN472A 72.0 2 118 125 123 125 20 TCD241C4 AYDHTRL427A 27.0 2 51 60 TC*241C4 AYDHTRL436A/AYHHTRN436A 36.0 2 64 70 68 70 AYDHTRL454A/AYHHTRN454A 54.0 2 91 100 95 100 AYDHTRK472A/AYHHTRN472A 72.0 2 118 125 123 125 25 TCD301C4 AYDHTRL427A 27.0 2 58 70 TC*301C4 AYDHTRL436A/AYHHTRN436A 36.0 2 68 70 - - AYDHTRL454A/AYHHTRN454A 54.0 2 95 100 - - AYDHTRK472A/AYHHTRN472A 72.0 2 123 125 - - 575 Volts Three Phase 121 TC*151CW AYDHTRKW18A/AYHHTRNW18A 18.0 1 27 30 30 35 AYDHTRMW36A/AYHHTRPW36A 36.0 2 49 50 51 60 AYDHTRKW54A/AYHHTRPW54A 54.0 2 70 70 73 80 15 TC*181CW AYDHTRKW18A/AYHHTRMW18A 18.0 1 29 40 31 40 AYDHTRMW36A/AYHHTRMW36A 36.0 2 49 50 31 40 AYDHTRKW54A/AYHHTRMW54A 54.0 2 70 70 73 80 171/2 TC*211CW AYDHTRMW36A/AYHHTRMW36A 36.0 2 51 60 55 60 AYDHTRLW54A/AYHHTRNW54A 54.0 2 73 80 77 80 AYDHTRKW72A/AYHHTRNW72A 72.0 2 95 100 98 100 20 TC*241CW AYDHTRMW36A/AYHHTRMW36A 36.0 2 51 60 55 60 AYDHTRLW54A/AYHHTRNW54A 54.0 2 73 80 77 80 AYDHTRKW72A/AYHHTRNW72A 72.0 2 95 100 98 100 25 TC*301CW AYDHTRMW36A/AYHHTRMW36A 36.0 2 55 60 - - AYDHTRLW54A/AYHHTRNW54A 54.0 2 77 80 - - AYDHTRKW72A/AYHHTRNW72A 72.0 2 98 100 - - 00) Values do not include power exhaust accessory. * Indicates both downflow and horizontal units. RT-PRCO24-EN 79 TRAIN' Electrical Data (High Efficiency) Table 70. Unit Wiring with Electric Heat (Single Point Connection) - TXV/Face-Split Evaporator Coil or Dehumidification (Hot Gas Reheat) Refrigeration System (Downflow only) Standard Indoor Motor Oversize Indoor Motor Max Fuse Size Max Fuse Size Unit Model Heater Model Heater kW Control or Max Circuit or Max Circuit Tons Number Number(') Rating Stages Control Breaker MCA Breaker(°) 208/230 Volts Three Phase 121/2 TCD151C3 AYDHTRK318A 13.5/18.0 1 61/68 70/70 68/76 80/80 AYDHTRK336A 27.0/36.0 2 108/122 110/125 115/130 125/150 AYDHTRK354A 40.5/54.0 2 154/176 175/200 162/184 175/200 15 TCD181C3 TCD181C3 AYDHTRK318A 13.5/18.0 1 74/74 100/100 80/80 90/90 AYDHTRK336A 27.0/36.0 2 108/122 110/125 115/130 125/150 AYDHTRK354A 40.5/54.0 2 154/176 175/200 162/184 175/200 *AYDHTRK318A 13.5/18.0 1 71/71 90/90 77/77 100/100 171/2 TCD211C3 AYDHTRL336A 27.0/36.0 2 115/130 125/150 125/139 125/150 AYDHTRL354A 40.5/54.0 2 162/184 175/200 171/193 175/200 AYDHTRK372A 54.0/72.0 2 209/238 225/250 218/247 225/250 20 TCD241C3 AYDHTRL336A 27.0/36.0 2 115/130 125/150 125/139 125/150 AYDHTRL354A 40.5/54.0 2 162/184 175/200 171/193 175/200 AYDHTRK372A 54.0/72.0 2 209/238 225/250 218/247 225/250 AYDHTRL336A 27.0/36.0 2 125/139 150/150 AYDHTRL354A 40.5/54.0 2 171/193 175/200 AYDHTRK372A 54.0/72.0 2 218/247 225/250 25 TCD301C3 460 Volts Three Phase 121/2 TCD151C4 AYDHTRL418A 18.0 1 34 35 37 40 AYDHTRK436A 36.0 2 61 70 64 70 AYDHTRK454A 54.0 2 88 90 91 100 15 TCD181C4 AYDHTRL418A 18.0 1 37 50 39 50 AYDHTRK427A3 27.0 2 47 50 - - AYDHTRK436A 36.0 2 61 70 64 70 AYDHTRK454A 54.0 2 88 90 91 100 TCD181C4 *AYDHTRL418A 18.0 1 36 45 39 50 171 TCD211C4 AYDHTRL427A3 27.0 2 51 60 - - AYDHTRL436A 36.0 2 64 70 68 70 AYDHTRL454A 54.0 2 91 100 95 100 AYDHTRK472A 72.0 2 118 125 123 125 20 TCD241C4 AYDHTRL427A3 27.0 2 51 60 - - AYDHTRL436A 36.0 2 64 70 68 70 AYDHTRL454A 54.0 2 91 100 95 100 AYDHTRK472A 72.0 2 118 125 123 125 25 TCD301C4 AYDHTRL427A3 27.0 2 57 70 AYDHTRL436A 36.0 2 68 70 AYDHTRL454A 54.0 2 95 100 AYDHTRK472A 72.0 2 123 125 575 Volts Three Phase 121/2 TCD151CW AYDHTRKW18A 18.0 1 27 30 30 30 AYDHTRMW36A 36.0 2 49 50 51 60 AYDHTRKW54A 54.0 2 70 70 73 80 15 TCD181CW AYDHTRKW18A 18.0 1 30 40 32 40 AYDHTRMW36A 36.0 2 49 50 51 60 AYDHTRKW54A 54.0 2 70 70 73 80 TCD181CW *AYDHTRKW18A 18.0 1 28 35 30 40 17'/2 TCD211CW AYDHTRMW36A 36.0 2 51 60 55 60 AYDHTRLW54A 54.0 2 73 80 77 80 AYDHTRKW72A 72.0 2 95 100 98 100 20 TCD241CW AYDHTRMW36A 36.0 2 51 60 55 60 AYDHTRLW54A 54.0 2 73 80 77 80 AYDHTRKW72A 72.0 2 95 100 98 100 80 RT-PRCO24-E N • TRANE° Electrical Data (High Efficiency) Table 70. (continued) Unit Wiring with Electric Heat (Single Point Connection) - TXV/Face-Split Evaporator Coil or Dehumidification (Hot Gas Reheat) Refrigeration System (Downflow only) Standard Indoor Motor Oversize Indoor Motor Max Fuse Size Max Fuse Size Unit Model Heater Model Heater kW Control or Max Circuit or Max Circuit Tons Number Number Rating Stages Control Breaker MCA Breaker 25 TCD301CW AYDHTRMW36A 36.0 2 55 60 - - AYDHTRLW54A 54.0 2 77 80 - - AYDHTRKW72A 72.0 2 98 100 - - (') For Heater Model Numbers: AYDHTRK427A and AYDHTRL427A do not use oversized motor. (°) Values do not include power exhaust accessory. *Applies only to Dehumidification (Hot Gas Reheat) Models. Table 71. Electrical Characteristics - Compressor Motor and Condenser Motor - 60 Cycle Compressor Motors Condenser Fan Motors Amps(() Amps Unit Model Tons Number No. Volts Phase HP(") RPM RLA LRA No. Phase HP FLA LRA 121/2 T/YC*151C3 2 208-230 3 5.70 3450 20.7 156 2 1 .50 3.2 8.8 T/YC*151C4 2 460 3 5.70 3450 10.0 75 2 1 .50 1.6 3.8 T/YC*151CW 2 575 3 5.70 3450 8.2 54 2 1 .50 :1.3 3.2 15 T/YC*181C3 2 208-230 3 9.30/4.50 3450 31.5/16.9 253/124 2 1 .50 3.2 8.8 T/YC*181C4 2 460 3 9.30/4.50 3450 15.1/8.2 113/59.6 2 1 .50 :1.6 3.8 T/YC*181CW 2 575 3 9.30/4.50 3450 12.1/6.6 85/49.4 2 1 .50 1.3 3.2 171/2 T/YC*211C3 2 208-230 3 10.0/5.70 3450 33.3/20.7 278/156 2 1 1.00 5.5 18.3 T/YC*211C4 2 460 3 10.0/5.70 3450 16.3/10.0 124/75 2 1 1.00 2.9 9.3 T/YC*211CW 2 575 3 10.0/5.70 3450 13.2/8.2 92/54 2 1 1.00 2.0 5.7 20 T/YC*241C3 2 208-230 3 9.30 3450 31.6 253 2 1 1.00 5.5 18.3 T/YC*241C4 2 460 3 9.30 3450 16.1 113 2 1 1.00 2.9 9.3 T/YC*241CW 2 575 3 9.30 3450 12.9 85 2 1 1.00 2.0 5.7 25 T/YC*301C3 2 208-230 3 10.00 3450 37.6 278 2 1 1.00 5.5 18.3 T/YC*301C4 2 460 3 10.00 3450 18.3 124 2 1 1.00 2.9 9.3 T/YC*301CW 2 575 3 10.00 3450 14.9 92 2 1 1.00 2.0 5.7 (i) For Compressor Motors and Condenser Fan Motors: Amp draw for each motor; multiply value by number of motors to determine total amps. (ii) HP for each compressor. *Indicates both downflow and horizontal units. Table 72. Electrical Characteristics - Compressor Motor and Condenser Motor - 60 Cycle - TXV/Face-Split Evaporator Coil Option (Downflow Only) Compressor Motors Condenser Fan Motors Amps(') Amps Unit Model Tons Number No. Volts Phase HP(") RPM RLA LRA No. Phase HP FLA LRA 12% T/YCD151C3 2 208-230 3 5.7 3450 18.6 156 2 1 .50 3.2 8.8 T/YCD151C4 2 460 3 5.7 3450 9.4 75 2 1 .50 1.6 3.8 T/YCD151CW 2 575 3 5.7 3450 7.4 54 2 1 .50 1.3 3.2 15 T/YCD181C3 2 208-230 3 9.30/4.50 3450 32.1/16.4 253/124 2 1 .50 3 2 8.8 T/YCD181C4 2 460 3 9.30/4.50 3450 15.6/8.7 113/59.6 2 1 .50 1 3.8 T/YCD181CW 2 575 3 9.30/4.50 3450 12.3/7.4 85/49.4 2 1 .50 1 3.2 171/2 T/YCD211C3 2 208-230 3 10.00/5.7 3450 34.8/19.5 278/156 2 1 1.00 5.5 18.3 T/YCD211C4 2 460 3 10.00/5.7 3450 17.0/10.3 124/75 2 1 1.00 2.9 9.3 T/YCD211CW 2 575 3 10.00/5.7 3450 13.8/8.1 92/54 2 1 1.00 2.0 5.7 20 T/YCD241C3 2 208-230 3 9.0/9.3 3500/3450 30.4/32.6 225/253 2 1 1.00 5 18.3 T/YCD241C4 2 460 3 9.0/9.3 3500/3450 16.1/16.8 114/113 2 1 1.00 2.9 9.3 T/YCD241CW 2 575 3 9.0/9.3 3500/3450 12.5/13.4 80/85 2 1 1.00 2.0 5.7 25 T/YCD301C3 2 208-230 3 10.00 3450 36.2 278 2 1 1.00 5.5 18.3 T/YCD301C4 2 460 3 10.00 3450 17.7 124 2 1 1.00 2 9.3 T/YCD301CW 2 575 3 10.00 3450 14.3 92 2 1 1.00 2.0 5.7 (') For Compressor Motors and Condenser Fan Motors: Amp draw for each motor; multiply value by number of motors to determine total amps. (ii) HP for each compressor. RT-PRCO24-EN 81 TRANE° Electrical Data (High Efficiency) Table 73. Electrical Characteristics - Compressor Motor and Condenser Motor - 60 Cycle - Dehumidification (Hot Gas Reheat) Option (Downflow Only) Compressor Motors Condenser Fan Motors Amps(') Amps Unit Model Tons Number No. Volts Phase HP1") RPM RLA LRA No. Phase HP FLA LRA 121/2 T/YCD151C3 2 208-230 3 5.7/5.7 3450 18.6 156 2 1 .50 3.2 8.8 T/YCD151C4 2 460 3 5.7/5.7 3450 9.7 75 2 1 .50 1.6 3.8 T/YCD151CW 2 575 3 5.7/5.7 3450 7.6 54 2 1 .50 1.3 3.2 15 T/YCD181C3 2 208-230 3 8.3/5.7 3450 27.4/19.0 208/156 2 1 .50 T/YCD181C4 2 460 3 8.3/5.7 3450 13.8/10.1 100/75 2 1 .50 T/YCD181CW 2 575 3 8.3/5.7 3450 10.7/7.9 68/54 2 1 .50 3.2 1.6 1.3 8.8 3.8 3.2 20 T/YCD241C3 2 208-230 3 9.0/9.3 3500/3450 30.1/31.7 225/253 2 1 1.00 T/YCD241C4 2 460 3 9.0/9.3 3500/3450 15.6/16.2 114/113 2 1 1.00 T/YCD241CW 2 575 3 9.0/9.3 3500/3450 12.1/13.0 80/85 2 1 1.00 5.5 2.9 2.0 18.3 9.3 5.7 0) For Compressor Motors and Condenser Fan Motors: Amp draw for each motor; multiply value by number of motors to determine total amps. (ii) HP for each compressor. Table 74. Electrical Characteristics - Evaporator Fan Motor - 60 Cycle - Standard and Oversized Standard Evaporator Fan Motor Oversized Evaporator Fan Motor Amps(') Amps Unit Model Tons Number No. Volts Phase HP(") FLA LRA No. Volts Phase HP FLA LRA 121h T/YC*151C3 1 208-230 3 3.00 10.6 81.0 1 208-230 3 5.00 16.7 109.8 T/YC*151C4 1 460 3 3.00 4.8 40.5 1 460 3 5.00 7.6 54.9 T/YC*151CW 1 575 3 3.00 3.9 31.0 1 575 3 5.00 6.1 41.6 15 T/YC*181C3 1 208-230 3 3.00 10.6 81.0 1 208-230 3 5.00 16.7 109.8 T/YC*181C4 1 460 3 3.00 4.8 40.5 1 460 3 5.00 7.6 54.9 T/YC*181CW 1 575 3 3.00 3.9 31.0 1 575 3 5.00 6.1 41.6 171h T/YC*211C3 1 208-230 3 5.00 16.7 109.8 1 208-230 3 7.50 24.2 120.4 T/YC*211C4 1 460 3 5.00 7.6 54.9 1 460 3 7.50 11.0 74.0 T/YC*211CW 1 575 3 5.00 6.1 41.6 1 575 3 7.50 9.0 60.0 20 T/YC*241C3 1 208-230 3 5.00 16.7 109.8 1 208-230 3 7.50 24.2 120.4 T/YC*241C4 1 460 3 5.00 7.6 54.9 1 460 3 7.50 11.0 74.0 T/YC*241CW 1 '575 3 5.00 6.1 41.6 1 575 3 7.50 9.0 60.0 25 T/YC*301C3 1 208-230 3 7.50 24.2 120.4 T/YC*301C4 1 460 3 7.50 11.0 74.0 T/YC*301CW 1 575 3 7.50 9.0 60.0 i') For Compressor Motors and Condenser Fan Motors: Amp draw for each motor; multiply value by number of motors to determine total amps. (ii) HP for each compressor. * Indicates downflow and horizontal units. Table 75. Electrical Characteristics - Combustion Blower Motor (Gas/Electric) Amps Unit Model Heat Heating HP RPMI') Volts Phase FLA Number Stages LRA YC*151 Low 2 1/20 3500/2800 208-230 1 0.5 0.78 YC*181, 211, 241-301 Low 2 1/10 3500/2800 208-230 1 0.8 2.00 0) High/Low Speed. * Indicates both downflow and horizontal units. Table 76. Electrical Characteristics - Power Exhaust (Cooling and Gas/Electric) Amps Tons Volts Phase HP RPM FLA LRA 121/2 208-230 1 3/4 1040 6.6 13.5 15,17'/z,20,25 460 1 3/4 1040 3.2 8.4 15,171/2,20,25 575 1 3/4 1040 2.1 5.2 82 RT-PRCO24-EN . MANE FILTER ACCESS DOOR HORIZONTAL ONLY DOWNFLOW CONDENSATE DRAIN CONNECTION 1.00 IN. NPT 71 5/8" 1811MM Dimensional Data 107 5/16" 27253 MM 3/16" 20 MM Illy//GiiL; aad\,11 ", vr9/l, „s„,A1 50 2/16” 1273 MM SINGLE POINT POWER ENTRY (TC" MODELS ONLY) 0.50 IN. NPT GAS INLET 1558-H; 0.75 IN. NPT 175 C -H; 0.75 IN NPT (YC" MODELS ONLY) 658" 150 MM 106 11/16" 2710 MM 2 /16' ! 69 MM 51 MM (21 DIA. HOLE (UNIT POWER WIRES) Figure 7. Cooling with Optional Electric Heat and Gas/Electric Models - 121/2 -17'/2 Tons Standard Efficiency; 121/ Tons High Efficiency * All dimensions are in inches/millimeters. **1/2 NPT Gas Connection = (Y_C Models only); 2" Electrical Connection: Single Point Power When Heat Installed (T_C Models only.) 70 13/16" 1798 MM 22 MM (7/8"1 DIA. HOLE (UNIT CONTROL WIRE) SERVICE GAUGE PORT ACCESS CLEARANCE 48" (1219 MM) CLEARANCE 60" (1524 MM) FILTER ACCESS DOOR HORIZONTAL UNITS ONLY X26 1/2" 673 MM ti CLEARANCE 18" (457 MM) 19916' 497 MM ".24 9/16" 624 MM ti 2" 5 MM Figure 8. Cooling with Optional Electric Heat and Gas/Electric Models -121/2-171h Tons Standard Efficiency; 121/2 Tons High Efficiency - Downflow Unit Clearance * All dimensions are in inches/millimeters. 15/16" 100 MM HORIZONTAL CONDENSATE'. DRAIN CONNECTION 1.0 IN. NPT CLEARANCE 38" (965 MM) 92 RT-PRCO24-E N MANE RT-PRCO24-EN Dimensional Data 1 1/2" (38 MMI PERIMETER CURB FLANGE 7 7/16" 189 MM 14 1/16" 66 5/8" 1692 MM 1600 MM 1 13/16" 46 MM (Standard and High Efficiency) 1"1017/8" 25 MM V 2588 MM l/ 63" Ad 5. 357 MM 51 MM Q• 1" 25 MM 2102 597 M 1/2" \\ 597 M" 1917 M"' \\ M 67" 1702 MM Figure 9. Cooling with Optional Electric Heat and Gas/Electric Models 121/-171/2 Tons Standard Efficiency -121/2 Tons IIgh Efficiency - Roof Curb * All dimensions are In inches/millimeters. 59 7/18' 1510 MM 1' 25 MM 17 7/P- 454 MM 7 7/16' 189MM 14 1/16' 357 MM 1' 25 MM 1 1/2' (38 MMC PERIMETER CURB FLANGE Figure 10. Cooling with Optional Electric Heat and Gas/Electric Models 121/2-171/2 Tons Standard Efficiency; 12% High Efficiency - Downflow Duct Connections - Field Fabricated * Duct flanges mount 7-7/16" down inside the curb on the 1-11/2 curb flanges. Roofcurb is intended for downflow use only. * All dimensions are in inches/millimeters. CLEARANCE 68" 1727 MM F / CLEARANCE FROM TOP OF UNIT 72" 1829 MM CLEARANCE 36" 914 MM r UNIT OUTLINE 621/2" / 1588 MM y i CLEARANCE 48" - 731/2" 1219 MM 1867 MM CLEARANCE 60" 1524 MM Figure 11. Cooling with Optional Electric Heat and Gas/Electric Models - 121/2 -171/2 Tons Standard Efficiency; 121/2 Tons High Efficiency - Horizontal Unit Supply/Return and Unit Clearance * All dimensions are in inches/millimeters. 93 Dimensional Data FILTER ACCESS DOOR HORIZONTAL ONLY DOWNFLOW CONDENSATE DRAIN CONNECTION 1.0 IN. NPT 85 5/16"� 2167 MM (Standard and High Efficiency) 122 5/16" 3107 MM % 9 MANE RT-PRCO24-EN Dimensional Data 1 1/2" (38 MMI PERIMETER CURB FLANGE 80 5/8" 7 7/16" 2048 MM 77 1956 MM 189 MM (Standard and High Efficiency) 25 MM 113/16" /, "-► 46 MM 116 7/8" 2969 MM 141/16" 357 MM 2" 51 MM 7 1/2" 1173/16" 191 MM 2977 MM 81" 2057 MM Figure 14. Cooling with Optional Electric Heat and Gas/Electric Models - 20-25 Tons Standard Efficiency; 15-25 Tons High Efficiency - Roof Curb * All dimensions are in Inches/millimeters. 25MAT Figure 15. Cooling with Optional Electric Heat and Gas/Electric Models - 20-25 Tons Standard Efficiency; 15-25 Tons High Efficiency - Downflow Duct Connections - Field Fabricated * Duct flanges mount 7-7/16" down inside the curb on the 1-11/z curb flanges. Roofcurb is intended for downflow use only. * All dimensions are in inches/millimeters. CLEARANCE 68" 1727 MM CLEARANCE 36" 914 MM r CLEARANCE FROM TOP OF UNIT 72" MM (1829 MMI 81" \�. 2057 MM UNIT OUTLINE 76 1/2" / 1943 MM /' CLEARANCE 48" / 1219 MM CLEARANCE 60" 1524 MM Figure 16. Cooling with Optional Electric Heat and Gas/Electric Models - 20-25 Tons Standard Efficiency; 15-25 Tons High Efficiency - Downflow Unit Clearance * All dimensions are in inches/millimeters. 95 Downflow Condensate Location Dimensional Data S U P P L Y H R I E T U R N K Horizontal Condensate G Location LF A C .—D Table 78. Standard Efficiency Units (Cooling and Gas/Electric) (121/2-25 Tons) Tons Downflow Only Condensate Drain Size Condensate Drain Location Downflow Horizontal A B C D F G H 3 K 121/2, 15, 171/2 20, 25 26 26 7/16 7/16 22 1/2 28 3/4 18 19 11/16 4 1/4 4 15/16 4 1/4 4 1/4 1/4 62 76 7/16 5/16 54 68 11/16 11/16 1 NPT 1 NPT 25 5/8 26 3/4 6 5 3/8 Table 79. High Efficiency Units (Cooling and Gas/Electric) Tons Downflow Only Condensate Drain Size Condensate Drain Location Downflow Horizontal A B C D F G H 3 K 121/2 15-25 26 26 7/16 7/16 22 1/2 28 3/4 18 19 11/16 4 1/4 4 15/16 4 1/4 4 1/4 1/4 62 76 7/16 5/16 54 68 11/16 11/16 1 NPT 1 NPT 25 5/8 26 3/4 6 5 3/8 96 RT-PRCO24-EN .0 MANE' Dimensional Data Table 80. Unit Model # (121-25 Tons) A B C TCD150, 151, 180, 210 42 3/8 TCD181, 211-301 29 1/2 48 3/8 31 56 381/2 All dimensions are in inches. ID SECTION ACCESS PANEL TOP VIEW SHOWING THROUGH THE BASE ELECTRICAL UTILITY LOCATIONS AND ACCESS PANEL SWING CLEARANCES 6 7/8" \ / ♦ / A -� --- / ♦♦ SWING DIA. FOR HINGED DOOR OPTION Figure 17. Cooling Unit - Swing Diameter & Through the Base Electrical THROUGH THE BASE ELECTRICAL OD SECTION ACCESS PANEL Table 81. Unit Model # A B C YCD150, 151, 180, 210 42 3/8 YCD181, 211-301 29 1/2 66 3/8 48 3/8 77 7/8 58 All dimensions are in inches. TOP VIEW SHOWING THE BASE UTILITY ELECTRICAL LOCATIONS AND PANEL SWING CLEARANCES SWING DIA. FOR HINGED DOOR OPTION THROUGH THE BASE GAS SEE DETAIL A 6 7/8" / \ 7 318" ♦♦ / SWING DIA. FOR HINGED DOOR OPTION HEIGHT OF GAS PIPE REQUIRED FROM INSIDE BASE OF UNIT TO GAS SHUT OFF ASSEMBLY (FACTORY PROVIDED) • ee THROUGH THE BASE ELECTRICAL OD SECTION ACCESS PANEL DETAILA 1''1 Figure 18. Gas/Electric Unit - Swing Diameter & Through the Base Electrical; Height of Gas Pipe (Second Drawing) RT-PRCO24-EN 97 Weights Table 83. Maximum Unit & Comer Weights (Lbs) and Center of Gravity Dimensions (in.) Cooling with Optional Electric Heat Units only m) Tons Unit Model No. Weights (Lbs)(I),00 Corner Weights Center of Gravity (in.) Shipping Net A B C D Length Width 121/2 TC*150D/TC*151C 1687/1820 TCD151C (Reheat Units) 1864 1319/1452 446/485 339/360 230/259 303/348 46/45 29/30 1496 496 371 270 359 45 30 15 TC*180B/TC*181C 1866/2361 TCD181C (Reheat Units) 2425 1498/1902 547/643 358/477 234/333 359/447 42/52 28/35 1966 659 493 349 463 52 35 171/2 TC*210C/TC*211C 2022/2380 1654/1921 565/643 425/495 285/341 378/442 46/53 29/35 20 TC*240B/TC*241C 2372/2490 1913/2031 TCD241C (Reheat Units) 2510 2051 679/697 482/528 312/348 440/458 51/53 34/34 702 533 353 463 53 34 25 TC*300B/ TC*301C 2365/2475 1906/2016 661/695 507/524 320/343 418/454 53/53 33/34 (1) Weights are approximate. Horizontal and downflow unit and comer weights may vary slightly. ISI) Weights do not include additional factory or field installed options/accessories. For option/accessory additional weights, reference Table 85, Table 86, Table 87 to be added to unit weights. (111) Corner weights are given for information only. 121/2-25 ton models must be supported continuously by a curb or equivalent frame support. * Indicates both downflow and horizontal units. CENTER OF GRAVITY �-- LENGTH CENTER OF GRAVITY WIDTH CENTER OF GRAVITY Table 84. Maximum Unit & Comer Weights (Lbs) and Center of Gravity Dimensions (in.) Gas/Electric Heat Units only Tons Unit Model No. Weights (Lbs)(I),III) Corner Weights(lll) Center of Gravity (in.) Shipping Net A B C D Length Width 121/2 YC*150D/YC*151C 1826/1915 YCD151C (Reheat Units) 1959 1458/1547 495/523 373/383 254/271 336/370 46/45 29/30 1591 534 394 282 381 45 30 15 YC*180B/YC*181C 2033/2464 YCD181C (Reheat Units) 2528 1665/2005 600/686 395/504 266/345 404/470 43/52 29/35 2069 697 515 356 481 52 35 171/2 YC*210C/YC*211C 2189/2547 1821/2088 618/701 463/538 317/369 424/480 46/53 29/35 20 YC*240B/YC*241C 2547/2645 YCD241C (Reheat Units) 2665 2088/2186 738/751 526/568 343/373 481/494 51/53 34/34 2206 756 573 378 499 53 34 25 YC*300B/YC*301C 2541/2650 2082/2191 721/755 552/569 351/373 458/495 53/53 33/34 (1) Weights are approximate. Horizontal and downflow unit and corner weights may vary slightly. 00 Weights do not include additional factory or field installed options/accessories. For option/accessory additional weights, reference Table 85, Table 86, Table 87 to be added to unit weights. (iii) Corner weights are given for information only. 12'/2-25 ton models must be supported continuously by a curb or equivalent frame support. * Indicates both downflow and horizontal units. RT-PRCO24-EN 99 TRANE Weights (121/2-25 Tons) Table 85. Accessory Net Weights (Lbs)(0 (') Unit Economizer Outside Air Damper Power Roof Oversized High Static Low Static LPG Model No. Net Manual Motorized Exhaust('') Curb(iv) Motor Adder Drive(") Drive(vl) Conversion Kit T/YCD150D,180B T/YCD151C,TCD210C 65 32 60 95 205 5 2 2 5 T/YCD240B T/YCD181,211,241C 80 32 75 95 235 5 2 — 5 T/YCD300B,301C 80 32 75 95 235 N/A N/A 2 5 T/YCH150D, 180B, 210C T/YCH151C 50 32 60 — — 5 2 2 5 T/YCH240B T/YCH181,211,241C 65 32 75 — — 5 2 — 5 T/YCH300B,301C 65 32 75 — — N/A N/A 2 5 (1) Net weight should be added to unit weight when ordering factory installed accessories. 01) TC* 150-300 factory installed options for economizers, multiply net capacity x .99, EER x .97. For oversized motors, multiply net capacity x .98, EER x .93. This is provided in compliance with ARI certification program. (111) Downflow only. (iv) Downflow only. (v) Not available on all models (See Fan Performance tables for specific models). (vi) Not available on all models (See Fan Performance tables for specific models). Table 86. (continued) Accessory Net Weights (Lbs) Electric Heaters Unit All 6-23 kW 27-36 kW 54 kW 72 kW Model No. Zone Sensors 240/480V('),(") 240/480V011),0v) 240/480V("),('') 240/480V(vii) (vil0 T/YCD150D, 180B, 210C 1 28/210) 31/27 38/32 T/YCD151,181C T/YCD240B T/YCD211,241C 1 33/27 40/32 43/34 T/YCD300B,301C — 33/27 40/32 43/34 T/YCH150D, 180B, 210C 1 28/2103 31/27 38/32 T/YCH151,181C T/YCH240B T/YCH211, 241C 1 33/27 40/32 43/34 T/YCH300B, 301C 1 — 33/27 40/32 43/34 (1) For 600V heaters net weights are same as 480V heaters. (11) To estimate shipping weight add 5 lbs to net weight. (01) For 600V heaters net weights are same as 480V heaters. (iv) To estimate shipping weight add 5 lbs to net weight. (v) For 600V heaters net weights are same as 480V heaters. (vi) To estimate shipping weight add 5 lbs to net weight. (v") For 600V heaters net weights are same as 480V heaters. (vili)To estimate shipping weight add 5 lbs to net weight. (Ix) 9 - 23 KW Heaters not available for TC*210C. (x) 9 - 23 KW Heaters not available for TC*210C. 100 RT-PRCO24-EN MANE Weights (121/2-25 Tons) Table 87. Factory Installed Options (FIOPS) Net Weights(i)(ii) Ilii► Accessory High Efficiency Motors(iv) Weight Unit Model Number 49 T/YC*150-181 standard size motor 36 T/YC*210-241 standard size motor T/YC*150-181 oversize motor 0 T/YC*210-241 oversize motor T/YC*300-301 standard size motor Hinged Doors 27 All T/YC* units Powered Convenience Outlet 38 All T/YC* units Through the Base Electrical 23 All T/YC* units Unit Mounted Circuit Breaker 5 All T/YC* units except those with 54&72 kW heaters & 208/230V 10 All T/YC* units with 54&72 kW heaters & 208/230V Unit Mounted Disconnect 5 All T/YC* units except those with 54&72 kW heaters & 208/230V 10 All T/YC* units with 54&72 kW heaters & 208/230V Smoke Detectors Supply/Return 5 All T/YC* units Stainless Steel Heat Exchanger 50 (150 MBh) 50 (250 MBh) 75 (350 MBh) 75 (400 MBh) YC*150,151 low heat YC*150,151 high heat YC*180,181,210,211,240,241,300,301 low heat YC*180,181,210,211 high heat YC*240,241,300,301 high heat Tool -less Hail Guard 38 T/YC*150,151,180,210 43 T/YC*181,211,240,241,300,301 Novar 2024 7 All T/YC* units Novar 3051 5 All T/YC* units (0 Weights for FIOP accessories not listed are >5 lbs. (0) Net weight should be added to unit weight when ordering factory installed accessories. (00 See Table 85, Table 86 for standard factory installed economizer and oversized motors. (0,) Standard factory installed motors are already included in unit net and shipping weights. Values shown for high efficiency motors are in addition to the standard motor weight. * Indicates both downflow and horizontal units. RT-PRCO24-EN 101 5/31/2019 City of Tukwila Department of Community Development KERRY BURR 601 DEVELOPMENT DR PLANO, TX 75074 RE: Permit No. M18-0104 LOWE'S 101 ANDOVER PARK E Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 7/15/2019. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 7/15/2019, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Kandace Nichols Permit Technician File No: M18-0104 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 August 31, 2018 / J City of Tukwila Department of Community Development KERRY BURR 601 DEVELOPMENT DR PLANO, TX 75074 RE: Correction Letter # 1 MECHANICAL Permit Application Number M 18-0104 LOWE'S - 101 ANDOVER PARK E Dear KERRY BURR, Allan Ekberg, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING - M DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments. • (GENERAL INFORMATION NOTE) PLAN SUBMITTALS: (Min. size 11x17 to a preferably maximum size of24x36; all sheets shall be the same size; larger sizes may be negotiable. "New revised" plan sheets shall be the same size sheets as those previously submitted.) "STAMP AND SIGNATURES" (If applicable) For Engineers: "Every page of a plan set must contain the seal/stamp, signature of the licensee(s) who prepared or who had direct supervision over the preparation of the work, and date of signature. Specifications that are prepared by or under the direct supervision of a licensee shall contain the seal/stamp, signature of the licensee and the date of signature. If the "specifications" prepared by a licensee are a portion of a bound specification document that contains specifications other than that of an engineering or land surveying nature, the licensee need only seal/stamp that portion or portions of the documents for which the licensee is responsible." It shall not be required to have each page of "specifications" (calculations) to be stamped and signed; Front page only will be sufficient (WAC 196-23-010 & 196-23-020). Architects: "date" only not required (WAC 308-12-081). (BUILDING REVIEW NOTES) 1. Provide plans that are full size to scale sheets, where notes are legible. Reduces sheets shall not be accepted. 2. Provide notes on the plan to show the weight of the existing compared with the new to show the weight has not been increased. If weight of the new units is more than the existing, an engineer's analysis shall be required to verify roof structure is sufficient to support the increase in weight of the new units. Note: Contingent on response to these corrections, further plan review may request for additional corrections. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 \ If you have any questions, I can bc. , cached at (206)433-7165. Sincerely, "I'S -11.11/ Rachelle Rip ey Permit Technicia File No. M18-0104 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 "PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M18-0104 PROJECT NAME: LOWE'S SITE ADDRESS: 101 ANDOVER PARK E Original Plan Submittal DATE: 10/01/18 Revision # before Permit Issued X Response to Correction Letter # 1 Revision # after Permit Issued DEPARTMENTS: �-�kiitX 10--t- Building Division 1111 Public Works Fire Prevention Structural Planning Division ❑ ❑ Permit Coordinator ri PRELIMINARY REVIEW: Not Applicable n (no approval/review required) REVIEWER'S INITIALS: DATE: 10/02/18 Structural Review Required DATE: APPROVALS OR CORRECTIONS: Approved DUE DATE: n Approved with Conditions Corrections Required ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: 10/23/18 REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping ❑ PW 0 Staff Initials: 12/18/2013 1 f , `PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP -w PERMIT NUMBER: M18-0104 DATE: 08/21/18 PROJECT NAME: LOWE'S SITE ADDRESS: 101 ANDOVER PARK E X Original Plan Submittal Response to Correction Letter # Revision # Revision # before Permit Issued after Permit Issued DEPARTMENTS: O, � � 4' Building l ivision Public Works ❑ kwo c64t6 Fire Prevention Structural Planning Division nPermit Coordinator n u PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 08/23/18 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 09/20/18 Approved Corrections Required ❑ Approved with Conditions ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only ���� CORRECTION LETTER MAILED: �n Departments issued corrections: Bldg [� Fire ❑ Ping D PW ❑ Staff Initials: f --P- 12/18/2013 Date: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Plan Check/Permit Number: M18-0104 0 Response to Incomplete Letter # ® Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner ❑ Deferred Submittal # Project Name: Lowe's Project Address: 101 Andover Park E Contact Person: KetZta9 Phone Number: 2 H ° 58 J-OlV Summary of Revision: .i. 3 Suers oC 2&1 >C SLo runt StZ : D2Awc,tctS Sleodoa'l C,r1co64:s For tri:A;„ / ta'YL 5 4-o Net.) RTu' , RECEIVED r` O TUK��'iLA SEP 2 6 2018 PERMIT CENTER Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: 0 Entered in TRAKiT on W:\Permit Center (Brenda)\Forms\Permit Center Documents (Word)\Revision Submittal Form.doc Revised: August 2015 NEXREV LLC Washington State Department of I Labor & Industries Ilmne Espal'iol Contact Safety & Health Claims & Insurance Page 1 of 2 Search L&I — -- I) A -Z Index Help My L.&I Workplace Rights Trades & Licensing NEXREV LLC Owner or tradesperson Principals SMITH, KENNETH RAY, PARTNER/MEMBER Doing business as NEXREV LLC WA UBI No. 602 566 931 601 Development Dr PLANO, TX 75074 972-578-0505 Business type Limited Liability Company Governing persons KENNETH SMITH KYM SMITH; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties HeatingNent/Air-Conditioning and Refrig (HVAC/R) License no. NEXREL*830RM Effective — expiration 12/14/2017-12/14/2019 Bond Travelers Cas and Surety Co of America Bond account no. 106839064 Active. Meets current requirements. $6,000.00 Received by L&I Effective date 12/08/2017 12/04/2017 Expiration date Until Canceled Insurance Phoenix Insurance Company, The $1,000,000.00 Policy no. 6300L00378118 Received by L&I Effective date 07/10/2018 06/29/2018 Expiration date 06/29/2019 Insurance history Savings .............. No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602566931&LIC=NEXREL*83ORM&SAW= 11/1/2018 NEXREV LLC L&I Tax debts No L&I tax debts are recorded for this contr.. ..Jr license during the previous 6 year period, but some ts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. This company has multiple workers' comp accounts. Active accounts L&I Account ID 179,258-00 ......_......._.. Doing business as NEXREV Estimated workers reported Quarter 3 of Year '4018 "Less than 1 Workers" L&I account contact T3 / DAVID PRYOR (360)902-4804 - Email: PRYD235@lni.wa.gov Track this contractor 0 Account is current. Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes ...................... ..... No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health No inspections during the previous 6 year period, Page 2 of 2 Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602566931&LIC=NEXREL*83ORM&SAW= 11/1/2018 • 8 0 z w 0 • • N 0 CO 0 0 N CO 0:26:25 A NOTE: CONTRACTOR SHALL VERIFY THAT TOP OF NEW CURB IS LEVEL PRIOR TO INSTALLING NEW UNIT. HOLD DOWN BRACKET; REF MANUFACTURER FOR SIZE, LOCATION AND ATTACHMENT REF SUPPLIER FOR CURB ADAPTER TO EXISTING CURB CONNECTION; PROVIDE MIN CONN OF #12 TEK SCREWS AT 6" OC J� NEW ROOF TOP UNIT (RTU) CURB ADAPTER (WHERE APPLICABLE) EXISTING CURB RTU TO CURB ADAPTER ATTACHMENT La SCALE: NTS SHEET NOTES: SHEET NOTES (CONT'D): SHEET NOTES (CONT'D): 1. ATTACH NEW UNIT TO CURB WITH HOLD DOWN CLIPS PROVIDED BY CURB SUPPLIER. NUMBER OF CLIPS AND LOCATIONS SHALL BE PROVIDED BY CURB SUPPLIER; REF 2-S1.0. 2. REPLACE EXISTING 17.5 TON RTU WITH NEW 17.5 TON RTU (2615#). EXISTING CURB TO REMAIN AND PROVIDE CURB ADAPTER AS REQUIRED (FIELD VERIFY) PER 2-S1.0. 3. REPLACE EXISTING 17.5 TON RTU WITH NEW 20 TON RTU (2715#). EXISTING CURB TO REMAIN AND PROVIDE CURB ADAPTER AS REQUIRED (FIELD VERIFY) PER 2-S1.0. 4. REPLACE EXISTING 2 TON RTU WITH NEW 3 TON RTU (762#). EXISTING CURB TO REMAIN AND PROVIDE CURB ADAPTER AS REQUIRED (FIELD VERIFY) PER 2-S1.0. 5. REPLACE EXISTING 12.5 TON RTU WITH NEW 13 TON RTU (2270#). EXISTING CURB TO REMAIN AND PROVIDE CURB ADAPTER AS REQUIRED (FIELD VERIFY) PER 2-S1.0. 6. REPLACE EXISTING 5 TON RTU WITH NEW 6 TON RTU (933#). EXISTING CURB TO REMAIN AND PROVIDE CURB ADAPTER AS REQUIRED (FIELD VERIFY) PER 2-S1.0. 7. REPLACE EXISTING 7.5 TON RTU WITH NEW 10 TON RTU (1326#). EXISTING CURB TO REMAIN AND PROVIDE CURB ADAPTER AS REQUIRED (FIELD VERIFY) PER 2-51.0. 8. REPLACE EXISTING 3 TON RTU WITH NEW 3 TON RTU (762#). EXISTING CURB TO REMAIN AND PROVIDE CURB ADAPTER AS REQUIRED (FIELD VERIFY) PER 2-S1.0. 9. REPLACE EXISTING 5 TON RTU WITH NEW 5 TON RTU (886#). EXISTING CURB TO REMAIN AND PROVIDE CURB ADAPTER AS REQUIRED (FIELD VERIFY) PER 2-S1.0. 10, REPLACE EXISTING 7.5 TON RTU WITH NEW 5 TON RTU (886#). EXISTING CURB TO REMAIN AND PROVIDE CURB ADAPTER AS REQUIRED (FIELD VERIFY) PER 2-S1.0. 11. REPLACE EXISTING 4 TON RTU WITH NEW 4 TON RTU (806#). EXISTING CURB TO REMAIN AND PROVIDE CURB ADAPTER AS REQUIRED (FIELD VERIFY) PER 2-S1.0. 12. REPLACE EXISTING 4 TON RTU WITH NEW 3 TON RTU (7620). EXISTING CURB TO REMAIN AND PROVIDE CURB ADAPTER AS REQUIRED (FIELD VERIFY) PER 2-S1.0. 13. REPLACE EXISTING 7.5 TON RTU WITH NEW 4 TON RTU (775#). EXISTING CURB TO REMAIN AND PROVIDE CURB ADAPTER AS REQUIRED (FIELD VERIFY) PER 2-S1.0. DESIGN LOADS 1. CODE 2. ROOF LIVE LOAD 3. GROUND SNOW LOAD 4. ULTIMATE WIND SPEED 5. SEISMIC COEFFICIENTS 6. SEISMIC DESIGN CATEGORY -I- EXISTING GLULAM 2015 INTERNATIONAL BUILDING CODE 20 PSF 25 PSF 110 MPH, EXP B, RISK CAT 2 SS = 1.453, Si = 0.542 D JUL 1. 204 EXISTING WOOD PURLINS EXISTING STEEL BEAMS REF & NO#9TE RTU -14 GIRDER, TYP ❑ REF NOTE #1 & #7 - RTU -20 RTU -7 REF NOTE #1 & #2 REF NOTE #1 & #2 REF NOTE #1 Sc #3 ❑ ❑ �.-- RTU - EX STING Tu- EXISTING WOOD PURLINS AT 8'-0" OC ❑ EXISTING STL BEAM GIRDER RTU -21 REF NOTE #1 & #6 REF NOTE #1 & #2 z LLI RTU -4 REF NOTE #1 & #2 EXISTING GREENHOUSE ROOF FRAMING PLAN SCALE: 1"=20'-0" RTU -6 'JUL REF NOTE #1 & #2--\1/4 REF NOTE #1 & #5 RTU -17 REF NOTE #1 & #2 RTUT-19 RTU -12 REF NOTE #1 & #11 RTU 18 REF NOTE" #1 & #6 0 _ REF NOTE #1 & #12-.. RTU -15 REF NOTE #1 & #10 z RTU -1 1 z RTU -9\ REF NOTE #1 & #10 RTU -16 REF NOTE #1 & #13 REF NOTE #1 & #8 LREF NOTE #1 & #8 REF NOTE #1 Sc #4- RTU -8 RTU -10 EXISTING VESTIBULE r J REF NOTE #1 & #9 L EXISTING CANOPY EXISTING CANOPY r EXISTING CANOPY r EXISTING CANOPY SEPAFIAi E 1 L.I SIT RECUiRED FOR: ❑ Mechanical Dgtectricat D'Plumbing as Piping My of Tukwila BUILDING DIVISION STRUCTURAL GENERAL NOTES: 0.0 CONSTRUCTION: 0.1 FURNISH ALL LABOR, MATERIALS AND EQUIPMENT NECESSARY TO COMPLETE THE WORK SHOWN OR IMPLIED BY THESE DRAWINGS. 0.2 THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL DIMENSIONS AND ELEVATIONS WITH THE MECHANICAL DRAWINGS AND THE EXISTING CONDITIONS. SEE MECHANICAL DRAWINGS FOR EMBEDDED ITEMS NOT SHOWN AND TO VERIFY SIZE AND LOCATION OF ALL OPENINGS. BEFORE EXECUTING WORK SHOWN HEREIN, THE CONTRACTOR SHALL EXAMINE ACTUAL JOB CONDITIONS AND REPORT TO THE ENGINEER ANY DISCREPANCIES OR FORSEEN PROBLEMS. 0.3 THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING THE EXISTING BUILDING DURING CONSTRUCTION. 0.4 THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR REVIEWING THE EXISTING FRAMING FOR OBVIOUS DEFECTS. ALL MEMBERS RECEIVING ROOF TOP UNITS ARE ASSUMED TO HAVE ONLY DUCTWORK AND LIGHTS ATTACHED TO THE MEMBER IN ADDITION TO THE RTU. THE CONTRACTOR SHALL NOTIFY THE ENGINEER AT ONCE IF ADDITIONAL ITEMS ARE ATTACHED TO THE MEMBER INCLUDING OTHER MECHANICAL EQUIPMENT, SPRINKLER LINES PARALLEL TO THE JOIST, OR MERCHANDISE. 0.5 CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO SUBMITTING FINAL BIDS. CONTRACTOR SHALL CAREFULLY COORDINATE NEW WORK AND DEMOLITION WITH ALL OTHER DISCIPLINES AND EXISTING CONDITIONS. ANY DAMAGE CAUSED BY CONTRACTOR SHALL BE REPAIRED TO OWNER'S SATISFACTION. 1.0 EXISTING FRAMING: 1.1 EXISTING FRAMING IS ASSUMED TO BE IN GOOD CONDITION. ANY DAMAGE TO EXISTING MEMBER SHALL BE REPORTED TO THE ENGINEER PRIOR TO ADDING LOAD TO MEMBER. (------I EXISTING CANOPY �- -L J- - - FILE COPY Permit No. N'S 0 (cLf Plan review approval is subject to errors and omissions. pproval of construction documents does not authorize 1violation of any adopted code or ordinance. Receipt f approved Field Copy and conditions is acknowledged: By: Date: 0/e City of Tukwila BUILDING DIVISION ss shu Ix? made t• the t"3'6i 's:iae 're'FLIr approval of Tu ro �2 EL�s?dna Division 114.111S } ' ; ;t,, r• t require a now pian submittal end " include addtionai Paan review fees, J REVIEWED FOR CODE COMPLIANCE APPROVED OCT 10 2018 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA SEP 2 6 2018 PERMIT CENTER \,01111E TION TR REVISIONS PRE-BID SETPOST BID SET ISSUE DATE O ISSUE DATE • DATE DESCRIPTION • • 0 8 •6 00 M • • • • LOWE'S HOME CENTERS, INC. 1605 CURTIS BRIDGE ROAD REEC DOCK WILKESBORO, NC 28697 336.658.4000 (V) 336.658,7138 (F) • • THIS DRAWING IS THE PROPERTY OF LOWE'S HOME CENTERS, LLC, ANY USE OR REPRODUCTION IN WHOL OR PART IS PROHIBITED WITHOUT THE EXPRESSED WRITTEN CONSENT OF LOWE'S HOME CENTERS, INC. COPYRIGHT 2017 ALL RIGHTS RESERVED 0 0 • STORE NUMBER: 0oo 41: z C7 z F- 0 J �- 00 Q <t 0 E. r.. 0 0= <C J 0010 ORIGINAL ISSUE DATE: PERMIT SET ISSUE DATE: 06.19.18 06.19.18 DRAWING NUMBER: S1 .0 • ROOF -TOP UNIT REPLACEMENT - ELECTRICAL SCHEDULE • REVISIONS O PRE-BID SET Q POSTBID SET ISSUE:DATE ISSUE DATE KEYED NOTES SHEET INDEX NOTE TO BIDDERS: DATE DESCRIPTION ROOF TOP UNIT DESCRIPTION EXISTING BREAKER TO REMAIN NEW BREAKER TO BE INSTALLED EXISTING FEEDER TO REMAIN NEW FEEDER TO E BINSTALLED NOTES: THESE CONTRACT DOCUMENTS HAVE BEEN DESIGNED AND DRAWN ASSUMING EXISTING BUILDING CONDITIONS MATCH THE ORIGINAL DRAWINGS. IT • HOWEVER, REMAINS THE RESPONSIBILITY OF THE EXISTING ROOF TOP UNIT SIZE SHALL BE FIELD VERIFIED PRIOR TO ANY WORK OR ORDERING OF NEW EQUIPMENT DUE TO LACK OF AS -BUILT INFORMATION. SHEET DESCRIPTION RTU01,03,04,05,06,07 REPLACE EXISTING 17.5 TON UNIT WITH NEW 17.5 TON UNIT - GAS HEAT YES N/A YES N/A 1, 3, 6 CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS PRIOR TO SUBMISSION OF A BID AND TO THE COMMENCEMENT OF ANY WORK. ANY DISCREPANCIES O TO NEW BMS CONTROL PANEL. CABLE TO BE TERMINATED ON PANEL BY NOVAR. EXISTING EXHAUST FAN TO REMAIN IN PLACE AND OPERATIONAL. E1.0 ROOFTOP UNIT REPLACEMENT ELECTRICAL PLAN AND NOTES • RTUO2 REPLACE EXISTING 17.5 TON UNIT WITH NEW 20 TON UNIT - GAS HEAT YES N/A YES N/A 1, 3, 6 FOUND BETWEEN WHAT IS SHOWN ON THE DRAWINGS AND THE EXISTING FIELD CONDITIONS SHALL BE • BROUGHT TO THE ATTENTION OF THE GENERAL CONTRACTOR OR LOWE'S PROJECT MANAGER TO DETERMINE WHAT ACTION SHOULD BE TAKEN.. O 22 GA. TWO CONDUCTOR TWISTED PAIR SHIELDED CABLE TIE -WRAPPED TO TOP OF BAR JOISTS. (BELDEN #3105A). OTO SWITCHGEAR AND PANELS ON REAR MEZZANINE.• O6 EXISTING UNIT HEATER TO REMAIN. ' RTUO8 REPLACE EXISTING 2 TON UNIT WITH NEW 3 TON UNIT - ELECTRIC HEAT . NO 15 AMP / 3 POLE NO (3)#10. (1)#10 G., 3/4"C. .2, 3 RTUO9 REPLACE EXISTING 3 TON UNIT WITH NEW 3 TON UNIT -GAS HEAT YES N/A YES • N/A 1, 3, 6 O 18 GA. TWO CONDUCTOR TWISTED PAIR SHIELDED CABLE TIE -WRAPPED TO TOP OF BAR JOISTS. (BELDEN #8760.) 8 EXISTING (3)18 GA. TWO CONDUCTOR TWISTED PAIR SHIELDED CABLES FOR THE EXISTING (3) OUTDOOR SENSORS. EXISTING OUTDOOR SENSORS TO BE RELOCATED TO NEW UNIT BY INSTALLING CONTRACTOR AND ORIENTED IN THE SAME DIRECTION AS THE ORIGINAL INSTALLATION. INSTALLING CONTRACTOR SHALL FIELD VERIFY CONNECTIONS ARE��vsr INTACT AND THAT THE SENSORS ARE OPERATIONAL. O TO SWITCHGEAR AND PANELS ON FRONT MEZZANINE. 10 NOT USED. 11 NOT USED. O 0 . INSTALL A 120 OHM, END OF UNE RESISTOR FOR THE COMMUNICATION LOOP. 13 CONTRACTOR SHALL REMOVE EXISTING CIRCUITRY, CONDUCTORS AND CONDUITS FOR EXISTING HVAC SYSTEM THAT IS BEING REPLACED, LABEL BREAKER(S) AS A "SPARE". NEW FEEDER/CIRCUIT SHALL BE ROUTED AND CONNECTED INTO FACTORY INSTALLED DISCONNECT ON NEW RTU. • ' RTU10 REPLACE EXISTING 5 TON UNIT WITHt, NEW 5 TON UNIT - ELECTRIC HEAT YES N/A YES N/A 1, 3, 6 ti ifrt, • . , ft '' . � O � T,...1 • • , 4r•', , ► 4 ' , . , ,«,�4 i 40g' 07.10.18• RTU11 REPLACE EXISTING 7.5 TON UNIT WITH NEW 5 TON UNIT - GAS HEAT YES N/A YES N/A 1 3 6 RTU12 REPLACE EXISTING 4 TON UNIT WITH NEW 4 TON UNIT - GAS HEAT YES N/A YES N/A 1, 3, 6 RTU13 REPLACE EXISTING 7.5 TON UNIT WITH NEW 5 TON UNIT - ELECTRIC HEAT YES N/A YES N/A 1; 3, 6 RTU14 REPLACE EXISTING 5 TON UNIT WITH NEW 5 TON UNIT ELECTRIC HEAT YES N/A YES N/A 1, 3, 6 RTU15 • REPLACE•EXISTING 4 TON UNIT WITH NEW 3 TON UNIT -.GAS HEAT14 YES • N/A.YES N/A 1, 3, 6 ' , V) H } g a dry �✓ at 0 "t g ' w •g ' w Z: � 2 2: ' �c RTU16 REPLACE EXISTING 3 TON UNIT WITH NEW 3 TON UNIT - GAS HEAT YES N/A YES • N/A 1, 3, 6 r-• � `-�' "' • �•� ^ • r--; r"_ t '� --" RTU17 REPLACE EXISTING 12.5 TON UNIT WITH NEW 13 TON UNIT - GAS HEAT NO 35 AMP / 3 POLE NO (3)#8. (1)#10 G., 3/4"C. 2, 3 , s���r_ :�t°�ii ' 4 .. CO EF -4 r RTUI8 REPLACE EXISTING 7.5 TON UNIT WITH 4 TON UNIT - ELECTRIC HEAT YES •N/A YES N/A 1, 3, 6 • © AC -32,34,36 0� �„n ONEW V (~_y RTU19 REPLACE EXISTING' S TON UNIT • WITH NEW 6 TON UNIT- GAS HEAT YES N/A YES N/A • 1, 3, 6 1 --• - •RTUO8 ® 'c © RTU20 REPLACE EXISTING .7.5 TON UNIT WITH NEW 10 TON UNIT - GAS HEAT YES N/A YES N/A 1, 3, 6 I e@ :.c © e@ ■III " H i• 0 U _ #2 ° H x x x 411111,1" • 'RTU20 RTU21 REPLACE EXISTING 5 TON UNIT_ WITH NEW 6 TON UNIT - GAS HEAT YES • N/A . YES. • N/A 1, 3,'6 D 1110( 0 1 I w [w MEM -- h n/ 1 ` O • ! !•FO. R NOTES: 1) RECONNECT EXISTING FEEDER CONDUCTORS TO NEW FACTORY INSTALLED INTEGRALLY MOUNTED DISCONNECT ON NEW RTU. 2).NEW CONDUIT/CONDUCTORS BACK TO'PANEL, CONNECT INTO NEW BREAKER.. 3 R MOVE. EXIST NG SENSOR CONDUIT,CABLE AND ASSOCIATED HARDWARE. ' ' ' ... F I. P L BLE 4 SEE SHEET E2.0 FOR NEW COMPUTER ROOM• RTU INSTALLATIONIN ORMATION. F A P ICA _ .PLACE AND SERVICE,NO A TI N•RE UIRED : IF. PLI ABLE 5)EXISTING' UNIT TO REMAIN'IN tN C . 0 Q AP C . ( '8 R CONNECT F�EISTING BRANCH .CIRCUIT CONDUCTORS TO NEW FACTORY' INSTALLED INTEGRALLY.MOUNTED GFC.1 CONVENIENCE RECEPTACLE•ON NEW.RTU.. .. E • RTUOT •R 01: TU • ,. : ► . _ _ : Q:. O, _.�. ,. . •• GONERAL E TES .. OWES OMECENTERS;INC. .. . •OAD �•L • 1805 CURTIS:BW)GEROAD REEL DOCK• WILKESBORO 'NC 28697 .. ... .. . 336 6 8. 0 5 4 000 (u) 336Z58.7138 (F) • ' . . ... 1:IT IS 'THE INTENT OF THE ELECTRICAL CONTRACT DOCUMENTS TO ENSURE THAT THELECTRICAL WORK A`T PERTAINS TO THER00 TOP.UNIT N I E F AND WORKMANLI E NNER. THE ELECTRICAL YSTEM' SHALL BET DAFTER CONNEGTIO CHANGEOUT AND ADDITIO S P RFORMED IN A SA E K MA......._....... S _ .. .... ...ES.TE .. A ...... .. _ . _ N . ... T SHALLBEREADY FOR.OPERATI .• CON .LILTS OR DEFlCIE CIES.FOUND WIT IN THE.CONTRACT DOCUMENTS SHALL BE BROUGHT TO 'NEW UNITS AND A ON F N H. S .... .,^r ATTENTION OF ,THE LQWE S PROJECT MANGER AND/OR THE ENGINEER OF RECORD PRIOR TO'ANY. WORK PROCEEDING. 2. FASTENING OF ANYTHING TO THE METAL ROOF:DECK IS PROHIBITED. ANY CONTRACTOR RESPONSIBLE FOR DRILLING; puNCHIN0OR OTHERWISE. P DAMAGEDSHEETS THE METAL ROOF DECK WILL BE REQUIRED TO.:REPLACE (NOT REPAIR) THE SH E S AT HIS EXPENSE.. 3. THE ELECTRICAL SUBCONTRACTOR SHALL PROVIDE ALL WORK AND MATERIAL FOR COMPLETE WIRING SYSTEMS AS SHOWN ON THESE DRAWINGS AND AS. SPECIFIED. 4. THE INSTALLATION SHALL COMPLY WITH THE CURRENT EDITION OF THE NATIONAL ELECTRICAL CODE, STATE AND LOCAL CODES..•'".' 5. ALL RACEWAYS SHALL BE RUN PARALLEL OR PERPENDICULAR TO STRUCTURAL MEMBERS, WALLS, CEILINGS, OR FLOORS. 6. ANY MATERIALS NEEDED TO FACILITATE THE SCOPE OF THIS PROJECT.SHALL BE NEW AND SHALL BE LISTED. BY UNDERWRITER'S LABORATORIES, INC. FOR THEIR INTENDED USE. 7. THE ELECTRICAL CONTRACTOR SHALL ARRANGE FOR AND PAY FOR ALL ELECTRICAL INSPECTION FEES AND INSPECTIONS. A COPY OF THE FINAL INSPECTION REPORT SHALL BE SUBMITTED TO THE OWNER. 8. PROVIDE ALL EXPANSION FITTINGS, PITCH POCKETS, EQUIPMENT SUPPORTS, AND ACCESS DOORS AS REQUIRED.FOR ELECTRICAL WORK. 9. ANY EXISTING LIQUID -TIGHT CONDUIT ROUTED ON THE EXTERIOR OF THE UNIT AND EXPOSED TO THE OUTDOOR ELEMENTS SHALL BE REPLACED FROM THE • POINT OF HARD PIPE CONNECTION TO UNIT. CARE SHALL BE TAKEN TO PREVENT DAMAGE TO THE EXISTING FEEDER CONDUCTORS AND ROOF MEMBRANE. 10. PROVIDE EQUIPMENT LABELS FOR DISCONNECT SWITCHES, WIRING TROUGHS, ETC. TO IDENTIFY EQUIPMENT OR EQUIPMENT SERVED. LABELS SHALL BE 1/8" THICK OF PHENOLIC MATERIAL, MACHINE ENGRAVED TO EXPOSE CONTRASTING INNER CORE. • . 11. ALL CONDUCTORS SHALL BE COPPER, TYPE THHNITHWN. #12 AWG SHALL BE THE MINIMUM SIZE USED FOR POWER WIRING: NO. 14 AWG MAY BE USED FOR CONTROL WIRING ONLY. 1.2. REFER TO MECHANICAL (M) AND STRUCTURAL (S) SHEETS FOR COORDINATION WITH OTHER TRADES AND POSSIBLE ADDITIONAL ELECTRICAL WORK. 13. ALL CONDUIT SHALL BE RUN IN THE AREA ABOVE THE BOTTOM CHORD OF THE ROOF JOISTS USING MANUFACTURER APPROVED CLIPS, HANGERS, TRAPEZE, ETC. (SEE NOTE 5 ABOVE). CONDUIT MAY REST ON BOTTOM CHORD OF JOISTS, BUT MAY NOT BE SUSPENDED BELOW THE JOISTS. ALL CONDUIT MUST BE ANCHORED AND FASTENED AT INTERVALS NOT EXCEEDING THOSE SPECIFIED IN THE N.E.C. : • � .... ..... -. ......... , ...... .. .... _ . _ . ... , . ::.... _ ..... :... ., , _ ..• _ ._ .. _ _ ...... ... ........ . . ..... �: .. .1 ,... • '< I ,^ ' -,'• .. .. ,0 DRAWING l9 7H8 PROPERTYOF LOYYE3 HOME • cENTEttB,LLC. ANY USE ORREPRODUCTION IN WHOLE • wwPrrEr�icotas°NEia$ro PROHIBITED WITHOUT •.PENETRATING COPYRIGHT ALL warns RESERVED V� .. / t : 1' / .. •'. •THIS RTU21 i .,' Q 1 N H fi,,.ehii 4',. Y W,oA!nM"aS4.,4+h'. Fl LmLJ3D' 0 0 ` . I - < {• � I -I • 7 • 7 s B a € a u) m z NEW RTU SENSORS . SEE (TYP.). 1 ._� DETAIL 2-E1.0.�) +F�p/}p1F♦y+`1 1_ REVIEWED ° UH #1 D . ° •©© H x x -U, x x FOR EpyC gO�MP/LIANCE. x._ APPROVED • O• : RTUO5 • ®�'1 T10 2��� . ii• • RTUO4 ; ' City Of Tukwila" _.,.' ��� _ _ p •BUILDING DIVISION • O Q / ` A • M � SI@ / . 0 .H x x —./ x Q x x . •— _ / / • / . AC -25,27,29 • 1 0 W i"" 2 O a a a /ti z © �,r,/ 0 0 o. c4 v m c3 • ROOF TOP UNIT SENSOR WIRING NOTES: ( RTU. 1. THE ELECTRICAL CONTRACTOR SHALL REMOVE THE EXISTING TEMPERATURE SENSOR CONDUIT, JUNCTION BOXES AND ASSOCIATED HARDWARE. SURFACE SHALL BE PREPARED FOR NEW SENSOR CONDUIT / AND JUNCTION BOXES. TYPICAL FOR LOCATIONS SHOWN ON FLOOR PLAN.ILI / RTUI7 RTU06 RTUO3 ■� . / lip/' 1 THE ELECTRICAL CONTRACTOR SHALL MOUNT A SHALLOW 4 -SQUARE NOTE:0 O 1 . x n �r ._....�. _......... Z_.._..._. �— 0 O �O RTU12 Q 2. JUNCTION BOX AT 6' A.F.F. FOR CO2 SENSOR AND 8' A.F.F. FOR TEMPERATURE SENSOR AT LOCATIONS NOTED ON THE FLOOR PLAN. 3/4" CONDUIT, WITH COMPRESSION CONNECTORS, SHALL BE INSTALLED BETWEEN THE (2) JUNCTION BOXES AND EXTENDED UP THE COLUMN TO WITH THE NEW SENSORS SHALL BE ORIENTED IN DIRECTION OF ORIGINAL SENSORS. - 3/4" EMT, JUNCTION BOX & WIRING ['OP UNIT REPLACE 'RICAL PLAN AND N 18107 DRAWN BY: DBV CHECI 4 I _ 0 ( 4-4EF-12O /� \ �T I ( EF -4 , THE CONTROL SECTION OF THE ROOF TOP UNIT. COORDINATE MECHANICAL CONTRACTOR FOR EXACT LOCATION OF CONTROL SECTION OF UNIT. ORIENT NEW SENSOR JUNCTION BOXES IN SAME DIRECTION AS REMOVED SENSOR JUNCTION BOX OR BEST PROTECTED _,YV__ /L BY ELECTRICAL CONTRACTOR. ' COORDINATE WITH MECHANICAL CONTRACTOR FOR EXACT SENSOR , ------ Q x , x x x 04PREVIOUSLY F TI SNIT ' • L I I '.'tD •_ _•_ co EF -12 0 © RTU11 1 F 'EIVED LOCATION. • LOCATION.L 3. ALL SENSOR WIRING SHALL BE PROVIDED BY THE ELECTRICAL COLUMN CONTRACTOR AND SHALL BE ROUTED FROM THE ROOF TOP UNIT TO THE LI RTU19 � _ _ s Cr --t x RTU18 RTUO9 IT G T U K W I L A © RTUI3 RTU15 I'D EF -7 E 2 APPROPRIATE JUNCTION BOX. INSTALL BELDEN 8760 TO TEMPERATURE SENSOR JUNCTION BOX AND BELDEN 7895A TO CO2 SENSOR JUNCTION • TEMPERATURE SENSOR BY ) MECHANICAL CONTRACTOR. 1 ® O 6 2018 EF -5 1 © 0 • 1O 0 0 0 PERM © CENTER " BOX. THERE SHALL BE 2' ADDITIONAL CABLE LENGTH IN THE ROOF TOP UNIT CONTROL SECTION AND IN EACH JUNCTION BOX TO ALLOW THE MECHANICAL CONTRACTOR TO MAKE FINAL CONNECTIONS TO THE UNIT AND SENSORS WITHOUT REQUIRING ANY SPLICES.. ' I j , — Q W Q ..1 IX W (— QioN 00 D .Q rJ i`- t) 111 B a __ 1 LLO.F-10 © ' O ° m o m,. x x i 1 E 0 RTU16 0 EF- CO 4. THE ELECTRICAL CONTRACTOR SHALL ENSURE THAT EACH CABLE BE I CO2 SENSOR BY MECHANICAL MI El RTU14 — / EF -09 (0 EF -05 .= RTU10 PROPERLY TAGGED AT EACH END, OHMED OUT AND TESTED. FOR BOTH OPENS AND/OR SHORTS. HVAC UNIT COMMISSIONING CONTRACTOR CONTRACTOR. u•• 9 Q 0 I STORE 0010 PLUMBER: ' 3 --•'• 0 SHALL BE RESPONSIBLE FOR FINAL CONNECTIONS OF INDOOR SENSORS SUCH AS FLAT PLATE SENSORS, CO2 SENSORS AND RECONNECTION OF 1 1 —°— --1-- -+---t -- , p °-4-�- ��l . BUILDING MANAGEMENT SYSTEM COMMUNICATIONS LINK WIRING TO ROOF -TOP -UNITS (ALL TERMINATIONS WILL OCCUR AT EACH UNITS TERMINAL STRIP). � V c I= -' ORIGINAL ISSUE DATE: •� �'1O— �i A `�J `! `i �' _ '.: / M ` " T �„ ` "� " --I '' PERMIT SET ISSUE DATE: 4,� t� -- — " — `" .�. I A 4 t • _�: DRAWING NUMBER: E 1 . 0 5. NO SPLICES WILL BE ALLOWED IN THE SENSOR WIRING. CONTINUOUS RUNS MUST EXTEND FROM THE UNIT TO THE SENSOR. --I I' �- `� --- • �� RTU SENSOR WIRING •„ 02 SALES FLOOR - HVAC ELECTRICAL PLAN 01 SCALE: NTS , . tl �' SCALE: 1"=20'-0" • ROOF -TOP UNIT REPLACEMENT - WORK OUTLINE MECHANICAL LEGEND KEYED NOTES SHEET INDEX ROOF TOP UNIT DESCRIPTION CURB ADAPTOR RTU01,03,04,05,06,07 REPLACE EXISTING 17.5 TON UNIT WITH NEW 17.5 TON UNIT - GAS HEAT TO BE FIELD & PROVIDED VERIFIED BY OWNER AS REQUIRED I_ 1 c ROOFTOP PACKAGED HEATING & COOLING UNIT (RTU) RTUO2 REPLACE EXISTING 17.5 TON UNIT WITH NEW 20 TON UNIT - GAS HEAT TO BE FIELD & PROVIDED VERIFIED BY OWNER AS REQUIRED RTUO8 REPLACE EXISTING 2 TON UNIT WITH NEW 3 TON UNIT - ELECTRIC HEAT TO BE FIELD & PROVIDED VERIFIED BY OWNER AS REQUIRED SUPPLY AIR DIFFUSER - ARROWS INDICATE PATTERN. NO PATTERN SHOWN EQUALS 4 -WAY RECTANGULAR DUCTWORK. SIZE • 12x16 l INDICATED IN INCHES, FIRST NUMBER IS SIDE SHOWN SQ TEMPERATURE SENSOR RETURN AIR GRILLE ® CO2 SENSOR RTUO9 REPLACE EXISTING 3 TON UNIT WITH NEW 3 TON UNIT - GAS HEAT TO BE FIELD & PROVIDED VERIFIED BY OWNER AS REQUIRED RTU10 RTU11 RTU12 RTU13 REPLACE EXISTING 5 TON UNIT WITH NEW 5 TON UNIT - ELECTRIC HEAT REPLACE EXISTING 7.5 TON UNIT WITH. NEW 5 TON UNIT - GAS HEAT REPLACE EXISTING 4 TON UNIT WITH NEW.4 TON UNIT - GAS HEAT EXISTING 7.5 TON UNIT WITH NEW 5 TON UNIT - ELECTRIC HEAT TO BE FIELD & PROVIDED TO BE FIELD & PROVIDED .TO BE FIELD & PROVIDED TO BE FIELD & PROVIDED VERIFIED BY OWNER AS REQUIRED VERIFIED BY OWNER AS REQUIRED VERIFIED BY OWNER AS REQUIRED VERIFIED BY OWNER AS REQUIRED ROUND DUCTWORK. DIAMETER INDICATED IN INCHES CFM CUBIC FEET PER MINUTE QT TEMPERATURE/HUMIDITY SENSOR O EXISTING ROOF TOP UNIT SIZE SHALL BE FIELD VERIFIED PRIOR TO ANY WORK OR ORDERING OF NEW EQUIPMENT DUE TO LACK OF AS -BUILT INFORMATION. O CONTRACTOR SHALL LOCATE NEW CO2 SENSOR AND TEMP SENSOR TO AVOID ANY CONFLICT WITH THE EXISTING MERCHANDISING RACKS. O EXISTING GAS UNIT HEATER (UH) TO REMAIN IN PLACE AND IN SERVICE. 04 NOT USED O REBALANCE SUPPLY AIR TO EACH INDIVIDUAL SPACE AS REQUIRED TO GET A UNIFORM TEMPERATURE IN EACH INDIVIDUAL SPACE. O EXISTING ELECTRIC RADIANT HEATER (CH) TO REMAIN IN PLACE AND IN SERVICE. SHEET DESCRIPTION M1.0 ROOFTOP UNIT REPLACEMENT MECHANICAL PLAN AND NOTES M2.0 MECHANICAL DETAILS . M3.0 MECHANICAL SCHEDULES, LEGENDS, DETAILS, AND NOTES RTU14 RTU15 RTU16 RTU17 RTU.18 RTU19. RTU20 RTU21 EXISTING 5 TON UNIT WITH NEW 5 TON UNIT ELECTRIC HEAT EXISTING 4 TON UNIT WITH NEW'3 TON UNIT - GAS HEAT EXISTING 3 TON UNIT WITH NEW 3 TON UNIT - GAS HEAT EXISTING 12.5 TON UNIT WITH NEW 13 TON UNIT - GAS HEAT EXISTING 7.5 TON UNIT WITH NEW 4 TON UNIT - ELECTRIC HEAT EXISTING 5 TON UNIT WITH NEW 6 TON UNIT - ELECTRIC HEAT. EXISTING 7.5 TON UNIT WITH NEW 10 TON UNIT - ELECTRIC HEAT EXISTING 5 TON UNIT WITH NEW 6 TON UNIT - GAS HEAT EXISTING ROOF TOP UNIT SIZE SHALL BE FIELD VERIFIED PRIOR TO ANY DUE TO LACK OF CURRENT AS -BUILT INFORMATION. NOTE TO BIDDERS:.' .: THESE.`CONTRACT; DOCUMENTS HAVE BEEN DESIGNED AND. DRAWN ASSUMING EXISTING BUILDING. CONDITIONS MATCH THE ORIGINAL DRAWINGS:: IT HOWEVER REMAINS . . THE RESPONSIBILITY,OF THE CONTRACTOR TO VERIFY ALL. EXISTING CONDITIONS PRIOR TO SUBMISSION OF A BID: AND TO THE COMMENCEMENT: OF ANY WORK ANY DISCREPANCIESI"OUND BETWEEN WHAT IS SHOWN.ON. THE DRAWINGS AND THE EXISTING FIELD CONDITIONS.: SHALL BE BROUGHT;, TO THE ATTENTION OF THE. GENERAL : CONTRACTOR OR LOWE'S PROJECT MANAGER TO • `. DETERMINE WHAT ACTION SHOULD BE TAKEN. TO BE FIELD & PROVIDED TO BE FIELD & PROVIDED TO BE FIELD & PROVIDED TO BE FIELD & PROVIDED TO BE FIELD &PROVIDED TO BE FIELD & PROVIDED TO BE FIELD & PROVIDED TO BE FIELD & PROVIDED WORK OR ORDER VERIFIED BY OWNER AS REQUIRED VERIFIED BY OWNER AS REQUIRED VERIFIED BY OWNER AS REQUIRED VERIFIED BY OWNER AS REQUIRED VERIFIED BY OWNER AS REQUIRED VERIFIED BY OWNER AS REQUIRED VERIFIED BY OWNER AS REQUIRED VERIFIED BY OWNER AS REQUIRED ING OF NEW EQUIPMENT O 0 REVISIONS OPRE -SID SET Q POST BID SET ISSUE DATE ISSUE DATE DATE DESCRIPTION • • EXISTING EF -4 TO REMAIN IN PLACE AND OPERATIONAL (TYPICAL) EXISTING 1" NEW LOAD S 260 MBH - RTUO8 EXISTING 7.5 TON RTU -20 TO BE REPLACED WITH NEW 10 TON UNIT EXISTING 17.5 TON RTU -07 TO BE REPLACED WITH NEW 17.5 TON UNIT RTUO7 RTU01 EXISTING 17.5 TON RTU -01 TO BE REPLACED WITH NEW 17.5 TON UNIT EXISTING 1-3 TO REMAIN IN: PLACE AND OPERATIONAL • LOWE'S HOME CENTERS; INC. 1605 CURTIS: BRIDGE ROAD: , REEC DOCK WILKESBORO; NC 28697 336.658:000. (V) :336.658.7138 (F) •. THIS DRAWWO IS THE PROPERTY OP LOWE'B HCME CENTERS. U.C. ANY USE OR REPRODUCTION IN WHOLE OR PART IS PROHIeITED.WITHOUTTHE EXPRESSED WRITTEN CONSENT OF LOWE'S HOME CENTERS, INC:. COPYRIOHT 2018 ALL RIGHTS RESERVED . . EXISTING 17.5 TON RTU402 TO BE REPL, CED WITH NEW. 20:.TON 'UNIT RTU21 SALES FLOOR- REPLACEMENT RTU MECHANICAL .PLAN • EXISTING GAS METER EXISTING 1-1/4" NEW LOAD 11 MBH ,11 f=f- XISTING 2-1/2" EXISTING 2-1/2" NEW LOADNEW LOAD 2,029 MBH U2,018 MBH UH #1 EXISTING 2" NEW LOAD 1,494 MBH 'EXISTING 5 TON: • RTU -21:.70 BE • •• REPLACED WITH 1 NEW 6 TON UNIT O 0 EXISTING 2-1/2" NEW LOAD 1,754 MBH EXISTING 2-1/2" NEW LOAD 1,754 MBH EXISTING 2" NEW LOAD 1,234 MBH • I I EXISTING 1-1/4" NEW LOAD 520 MBH H 11 ZO= h -I 2 8 RTU05 2 O z 0 0 p J.2 6zcTI 1-114" GAS DOWN TO GREENHOUSE EXISTING 17.5 TON RTU -05 TO BE REPLACED WITH NEW 17.5 TON UNIT EXISTING 17.5 TON RTU -04 TO BE REPLACED WITH NEW 17.5 TON UNIT T CT 10.2018 t1t41. i .ins . EXISTING 1" NEW LOAD 260 MBH 0 EXISTING 17.5 TON RTU -06 TO BE REPLACED WITH NEW 17.5 TON UNIT EXISTING 17.5 TON RTU -03 TO BE REPLACED WITH NEW 17.5 TON UNIT RTUO3 RTUO6 'M X EXISTING 3/4" NEW LOAD 108 MBH z0m E w y� 6z�f EXISTING 4 TON RTU -15 TO BE REPLACED WITH NEW 3 TON UNIT EXISTING EF -12 TO REMAIN IN PLACE AND OPERATIONAL EXISTING EF -04-' TO REMAIN IN PLACE AND 4EF-12 EF -4 OPERATIONAL EXISTING 3/4" NEW LOAD 65 MBH EXISTING 12-1/2 TON RTU -17 TO BE REPLACED WITH NEW 13 TON UNIT RTU12 -EXISTIN& 4-TON--- RTU-12 TO BE EF -12 R EXISTING 5 TON • RTU -19 TO BE RTU19 REPLACED WITH NEW 6 TON UNIT O EXISTING RTU -16 TO RE NE TON {' BE WITH UNIT - X - EXISTING EF -05 TO REMAIN IN PLACE AND OPERATIONAL? -EXISTING 1-1/4" NEW LOAD 346 MBH R ITU 5 EF -5 RTU13 0 REPLACED WITH NEW 4 TON UNIT 00 s EXISTING 7.5 TON RTU -18 TO BE REPLACED WITH NEW 4 TON UNIT RTU18 EXISTING 3/4" NEW LOAD RTU16 108 MBH RTU14 ,t EXISTING § TON RTU -14 TO TO BE REPLACED WITH NEW 5 TON UNIT EXISTING 7.5 TON RTU -13 TO BE R PLACED WI NEW 5 TON UN H 0 00 EF -10 EF -09 EF -7 RTU17 00 EXISTING EF -07 TO REMAIN IN PLACE AND OPERATIONAL EXISTING 7.5 TON RTU -11 TO BE REPLACED WITH NEW 5 TON UNIT RTU11 EXISTING 3/4 NEW LOAD RTUO9 • 108 MBH RTU10 1-1/4" EXISTING 3/4" EXISTING 3/4" NEW LOAD NEW LOAD 173 MBH 65 MBH EXISTING 5 TON RTU -10 TO BE REPLACED WITH NEW EXIS RTU REP NEW N G3TON • TO BE CED WITH TON UNIT EXISTING EF -5 TO REMAIN IN PLACE AND OPERATIONAL EXISTING EF -1 TO REMAIN IN PLACE AND OPERATIONAL TO REMAIN IN PLACE AND OPERATIONAL EXISTING EF -9 • TO REMAIN IN PLACE AND OPERATIONAL SEP Z6 218 PERMIT CENTER SCALE: 01 0 STORE NUMBER: 0 c 13. z • V♦ WI- w0 0z w▪ z w z -I O z LL = O w • 2. O O co 24t,z � 52 z w-dz J ~ c!)Os, ./ (/ w _w 0 J 2 0 w 1 0 0010 ORIGINAL ISSUE DATE: PERMIT SET ISSUE DATE: 1"=20'-0" DRAWING NUMBER: M 1.0 • J CD 0 w 0 0 LOWE'S HVAC/AHU SALVAGE PROGRAM DESCRIPTION PACKAGED RTU CURB ADAPTOR .AN.D WIND SEISMIC NOTES LOWE'S HVAC/AHU SALVAGE REQUIREMENTS PROJECT LOCATIONS: USA (EXCLUDING AK, HI, PR) 1. AES INDUSTRIES, INC. MUST RECEIVE THE FOLLOWING EQUIPMENT WITH NO FREIGHT CHARGE (MINIMUM 30 TONS TOTAL) TO LOWE'S. REQUIRED ITEMS INCLUDE: -AIR HANDLING UNITS (AHU'S) - ROOF TOP UNITS (RTU'S) - AES RESPONSIBLE FOR REFRIGERANT RECOVERY -UNIT HEATERS THE CONTRACTOR MUST INCLUDE SALVAGE/ RECYCLING REQUIREMENTS, AND PACKAGING MATERIALS IN THE LOWE'S BID DOCUMENT PER THE FOLLOWING SPECIFICATION (NO EXCEPTION) THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL COSTS INCLUDING PACKAGING, HANDLING, AND COORDINATION WITH AES INDUSTRIES, INC. FOR THE SALVAGE REQUIREMENTS NOTED IN THE FOLLOWING SPECIFICATION. 2. REMOVAL OF ANY SALVAGE, EQUIPMENT OR DEBRIS FROM A LOWE'S PROJECT IS PROHIBITED (THIS INCLUDES THE SALE OF COPPER, ALUMINUM, OR ANY RELATED MATERIALS). 3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REMOVAL AND REPLACEMENT OF ALL HVAC AND AHU EQUIPMENT LISTED AND SHOWN ON THE PROJECT DOCUMENTS, OR AS REQUIRED TO COMPLETE THE SCOPE OF WORK. 4. THE CONTRACTOR SHALL REMAIN RESPONSIBLE FOR THE REMOVAL OF ALL. CONTROLS. EQUIPMENT FROM EXISTING UNITS, RETURNING CONTROL COMPONENTS TO THE LOWE'S MECHANICAL CONSTRUCTION MANAGER. 5. THE CONTRACTOR SHALL RECOVER ALL REFRIGERANTS FROM ALL CHILLER SYSTEMS SCHEDULED FOR REMOVAL.RECOVERY IS TO BE DONE IN ACCORDANCE WITH DUPONT REFRIGERATION BANKING PROGRAM. WHEN RECOVERING REFRIGERANT THE CONTRACTOR SHALL CONTACT DUPONT EITHER BY PHONE OR E-MAIL, PRIOR TO STARTING ANY REFRIGERANT REMOVAL FROM THE EXISTING SYSTEMS: 6. THE CONTRACTOR SHALL COORDINATE DELIVERY OF RECOVERY CONTAINERS, BY E-MAIL, STATING THE SIZE AND NUMBER OF CYLINDERS REQUIRED AND THE ADDRESS OF THE STORE LOCATION. 7. THE CONTRACTOR IS RESPONSIBLE FOR SECURE STORAGE ON SITE OF ALL CYLINDERS AND RECOVERED REFRIGERANT UNTIL THE TIME OF PICKUP BY THE ARRANGED CARRIER. ALL CYLINDERS MUST BE PROVIDED BY DUPONT REFRIGERANTS AND CHARGED DIRECTLY TO LOWE'S. 8. CONTRACTOR IS NOT RESPONSIBLE FOR PAYMENT OF CYLINDERS. IMMEDIATELY UPON COMPLETION OF THE RECOVERY PROCESS, THE CONTRACTOR SHALL ARRANGE FOR RETURN OF THE RECOVERED REFRIGERANT. AN E-MAIL SHALL BE SENT DIRECTLY TO DUPONT REFRIGERANTS A COPY TO THE LOWE'S CONSTRUCTION MANAGER. THIS E-MAIL SHALL INCLUDE THE SIZE OF THE CYLINDERS, NUMBERS OF FULUPARTIAUEMPTY CYLINDERS, TYPE OF REFRIGERANT, STORE LOCATION, AND CONTACT NAME AND. PHONE NUMBER FOR RESPONSIBLE PARTY ON THE JOB SITE. THE CYLINDERS MUST BE PROPERLY TAGGED WITH THE STORE NUMBER AND ADDRESS. 125 LB.CYLINDERS MUST BE PALLETIZED FOR TRANSPORTATION. CYLINDERS SHALL NOT BE FILLED BEYOND 80% CAPACITY AND SHALL NOT BE STORED IN EXTREME HEAT OR UNSECURED AREAS PRIOR TO SHIPPING. DOT REQUIRES THAT CYLINDERS BE SECURED AND BANDED ON PALLETS SO THERE IS NO MOVEMENT DURING SHIPPING. 9. THE CONTRACTOR SHALL CAREFULLY DOCUMENT THE AMOUNT OF REFRIGERANTS RECOVERED IN ACCORDANCE WITH LOWE'S POLICIES FOR REFRIGERANT RECOVERY INCLUDING THE SUBMISSION OF DOCUMENTATION TO LOWE'S. DURING REFRIGERANT REMOVAL CONTRACTOR MUST COMPLY WITH ALL EPA AND GOVERNMENTAL LAWS AND REGULATIONS. . 10. THE CONTRACTOR SHALL COORDINATE WITH THE STORE/CONSTRUCTION MANAGER AN AREA FOR TEMPORARY SALVAGE AND CONTAINER STORAGE ON GRADE IN A VIABLE SECURE LOCATION. 11. THE CONTRACTOR SHALL PROVIDE FOR A ONE WEEK NOTICE TO AES INDUSTRIES, INC. AS TO THE DATE AND TIME OF PICK-UP. CONTRACTOR MUST. COMPLETE THE AES REQUEST FOR PICKUP DOCUMENT. 12. CONTRACTOR SHALL PROVIDE ALL LABOR AND EQUIPMENT TO LOAD ALL SALVAGE EQUIPMENT..AND MATERIALS ONTO AES PROVIDED TRAILERS. ALL ,SALVAGE MATERIALS•MUST BE PROPERLY:PACKAGEDcAND.LOADED. ONTO AES. PROVIDED :TRAILERS: AIR HANDLING UNITS, AND.•RTU'S;MUST.HAVEALL . EXTERNAL ACCESSORIES REMOVED TO ALLOW FOR SAFE NON :OVER DIMENSIONAL•TRANSPORTATION :': DE : OR� FT VAN.Oft FLATBED. ,. T AESLOGISTICS. TYPE OF: E UIPME T INCLU S 48 53 R 3. THE CONTRACTOR. MUST SECURE THESE •ITEMS" IN ACCORDANCE WI H • , Q .. N , , , , ..:. ., . TRAILERS MUST BE LIVE:LOADED LTL WILL Be VAN: TRAILER SCHEDULING/LOGISTICS:'THE CONTRACTOR: MUST REQUEST. FROM AES INDUSTRIES THE • DATE FOR TRAILERS TO BE DELIVERED. ON SITE A MINIMUM OF 5 DAYS.:PRIOR: TO ARRIVAL.. LOADING TIME FORTRAILERSIFLATBEDS MUST NOT EXCEED.4. . • HOURS:. CONTRACTOR WILL BE RESPONSIBLE, FOR CHARGES IF LOADING. TIMES. EXCEED.4. HOURS OR.IF NUMBEROF TRAILERS' EXCEEDS THE ESTIMATE L WE' BID DOCUMENT: • REFRIGERANT. REMOVAL REQUIRED BY'AES INDUSTRIES: AHU/RTU EQUIPMENT :SHALL COMPLY.TOAND FOLLOW EPA NOTED ON.:LOWE'S S (. ) .... CLEAN:AIR ACT, TITLE VI, SECTION. 608 AND CODE OF FEDERAL REGULATION TITLE 40 PART 82 WHEN REMOVING AIRCONDITIONING OR REFRIGERATED EQUIPMENT UNITS: AES. SHALL DOCUMENTALL REMOVED EQUIPMENT• RECORDING THEIR IDENTIFICATION .NUMBERS; MODELAND SERIAL .NUMBERS:..: 1. ROOF CURBS. TO BE A MINIMUM OF 14 -INCH HIGH, ONE PIECE CONSTRUCTION. 2. CONSTRUCTION OF ADAPTERS SHALL BE 14-16 GAGE STEEL. 3. COMPONENTS INTERNAL TO THE CURB PERIMETER TO BE A MINIMUM OF 18 GAGE. 4. CURBS TO BE DESIGNED TO EFFICIENTLY TRANSITION FROM EXISTING CURB SIZE TO THE NEW RTU CURB SIZE. 5. PROVIDE 3" BAS FLANGE WITH PER -PUNCHED HOLES A MINIMUM OF 12" ON CENTER FOR SECUREMENT TO EXISTING CURB. 6. PROVIDE 1" DUCT LINER AR ALL PERIMETER WALLS AND AIR IMPACTED SURFACES. 7. CORNERS TO BE FULLY WELDED WITH CORNERS COATED WITH ELASTOMERIC SEALANT. ALL EXTERNAL SURFACES IMPACTED BY INTERIOR WELDS MUST BE PAINTED WITH ZINC RICH PRIMER. 8. FURNISH ROLLS OF 1.5"x25" ADHESIVE NEOPRENE GASKETING MATERIAL WITH CURB FOR FIELD MOUNTING. ROLLS TO BE SUFFICIENT LENGTH TO PROVIDE TWO LAYER OF GASKETING BETWEEN EXISTING CURB AND ADAPTER CURB. 9. FACTORY INSTALLED WIND/SEISMIC BRACKETS. BRACKETS MUST BE INCREASED IN SIZE OR QUANTITY TO MEET JURISDICTIONAL REQUIREMENTS. 10. PROVIDE ENGINEERING CALCULATIONS TO SUPPORT WIND LOADS IF REQUIRED BY AHJ. 11. CONTRACTOR MUST APPROVE SUBMITTAL DRAWINGS PRIOR TO CURB FABRICATION. LOWE'S NOR CURB MANUFACTURER WILL BE RESPONSIBLE FOR CHARGES INCURRED BY VERIFYING EXISTING CONDITIONS. 12: PROVIDE ELECTRICAL CHASE WITH CURB. U -BOLTS 1-1/4" CONDUIT OUTDOOR SENSOR ASSEMBLY SUPPLIED BY NOVAR. 3'-0" MAX. f CONTROL BOX MOUNTING • BRACKETS J RTU NOTES: 1. INSTALLING CONTRACTOR SHALL RELOCATE THE EXISTING OUTDOOR SENSOR ASSEMBLY. AND.WEATHERHEAD TO CORNER OF RTU CLOSEST. TO ELECTRICAL ROOM #1 (THE SAME RTU THAT THE (3)18 GA.,:TWO CONDUCTOR TWISTED` PAIR, BELDEN #8760 CABLES ARE ROUTED).: CONDUIT:'SHOULD EXTEND .1'-0" ABOVE..: BE ED. OF.USED. TOP OF RTU. MOUNT:WEATHERHEAD TO TOP CONDUIT. CABLES T0. TO CONNECT THE OUTDOOR SENSOR ASSEMBLY TO THE BMS.` THE CONTROLS. CONTRACTOR SHALL MOUNT OUTDOOR SENSOR ASSEMBLY.. AND MAKE FINAL CONNECTIONS AND ASSURE THAT SENSOR ASSEMBLY SHALL • BE FACING NORTH. OUTDOOR SENSOR ASSEMBLY; DETAI SCALE: NEOPRENE GASKET WOOD NAILER / 4-#10 SCREWS (PER RESTRAINT BRACKET) ROOF CURB / / r /////// / TYP. RTU 4410 SCREWS (PER RESTRAINT BRACKET) RESTRAINT BRACKET 1. ATTACH BRACKET TO INSIDE OF CURB USING (4) TEK SCREWS SUPPLIED AS SHOWN. ONE HIGH WIND BRACKET PER EACH SIDE OF RTU. NOTE-ATTATCH MOUNTING BRACKET TO CURB BEFORE MOUNTING UNIT ON CURB. 2. AFTER SETTING UNIT ON CURB, ATTACH BOTTOM OF BRACKET TO BASE RAIL OF UNIT WITH (4) TEK SCREWS SUPPLIED AS SHOWN. 3. HARDWARE PACKAGE TO BE ORDERED FOR UNIT WILL INCLUDE -ALL NECESSARY MOUNTING DEVICES FOR HIGH WIND BRACKET. J HVAC. • UNIT..;. r 34'. CONDUIT, JUNCTION � • BOXES & WIRING BY ELECTRICAL CONTRACTOR 8'-0" 6'-0" TEMPERATURE SENSOR BY MECHANICAL CONTRACTOR CO2. SENSOR BY MECHANICAL CONTRACTOR 0 5 LENNOX P298 24VAC OC SENSOR IAQ All 0 0 BLUE WHITE 8 7 6 5 4 3 2 1 0 CO2 SENSOR 4 J • NOTE: NEW SENSORS SHALL BE ORIENTED IN DIRECTION OF ORIGINAL SENSORS. NOTES: 1. THE MECHANICAL CONTRACTOR SHALL MOUNT THE TEMPERATURE SENSORS AND CO 2 SENSORS WHERE SHOWN IN PLAN VIEW. THE SENSOR WIRING, JUNCTION BOXES AND CONDUIT SHALL BE INSTALLED BY THE ELECTRICAL CONTRACTOR. 2. MECHANICAL CONTRACTOR SHALL MAKE FINAL CONNECTIONS OF TEMPERATURE SENSORS AND CO2 SENSORS. CONNECT BELDEN 8760, 1 -PAIR, TO TEMPERATURE SENSORS. CONNECT BELDEN 7895A TO CO 2 SENSORS. 7895A IS A 2 -PAIR, 4 -CONDUCTOR CABLE. THE RED/BLACK PAIR IS 24 -VOLT FROM RTU TO THE CO 2 SENSOR, THE BLUENVHITE PAIR IS CONTROL SIGNAL BETWEEN CO 2 SENSOR AND RTU CONTROL BOARD. 3. NO SPLICES WILL BE ALLOWED IN THE SENSOR WIRING ALL TERMINATIONS WILL OCCUR AT TERMINAL STRIPS AT THE SENSOR AND AT THE UNIT. 4. . ON THE DATE THAT THE HVAC UNIT COMMISSIONING CONTRACTOR IS ON SITE TO VERIFY THE COMMUNICATIONS LINK WIRING, THE MECHANICAL CONTRACTOR SHALL HAVE A TECHNICIAN ON SITE TO TERMINATE ALL BUILDING MANAGEMENT SYSTEM COMMUNICATIONS LINK WIRING CONNECTIONS TO THE ROOFTOP HVAC UNITS. BELDEN 8760 CABLE IN 3/4" CONDUIT INSTALLED BY ELECTRICAL CONTRACTOR. FINAL TERMINATION BY MECHANICAL CONTRACTOR. • Va" CONDUIT, JUNCTION BOXES & WIRING BY ELECTRICAL CONTRACTOR OFFICE CEILING TEMPERATURE OR TEMP/HUMIDITY SENSOR BY MECHANICAL CONTRACTOR 60" TEMPERATURE OR COMBINATION TEMPERATURE/HUMIDITY SENSOR Jr .....• . • •• OFFICE FLOOR NOTES: 1. THE MECHANICAL CONTRACTOR SHALL MOUNT THE TEMPERATURE OR COMBINATION TEMPERATURE/HUMIDITY SENSORS WHERE SHOWN ON PLAN VIEW. THE SENSOR WIRING, JUNCTION BOXES AND CONDUIT SHALL BE INSTALLED BY THE ELECTRICAL CONTRACTOR. MECHANICAL CONTRACTOR SHALL MAKE FINAL . CONNECTIONS OF TEMPERATURE OR TEMPERATUREIHUMIDITY SENSORS. CONNECT BELDEN 8760, 1 -PAIR, TO TEMPERATURE OR TEMPERATURE/HUMIDITY SENSORS. 2. NO SPLICES WILL BE ALLOWED IN THE SENSOR WIRING ALL TERMINATIONS WILL OCCUR AT TERMINAL STRIPS AT THE SENSOR AND AT THE UNIT. 3. ON THE DATE THAT THE HVAC UNIT COMMISSIONING CONTRACTOR IS ON SITE TO VERIFY THE COMMUNICATIONS LINK WIRING, THE MECHANICAL CONTRACTOR SHALL HAVE A TECHNICIAN ON SITE TO TERMINATE ALL BUILDING MANAGEMENT SYSTEM COMMUNICATIONS LINK WIRING CONNECTIONS TO THE ROOFTOP HVAC UNITS. NTS' NOTE TO BIDDERS • • THESE CONTRACT DOCUMENTS HAVE BEEN DESIGNED AND DRAWN ASSUMING EXISTING BUILDING CONDITIONS MATCH THE ORIGINAL DRAWINGS. IT HOWEVER, REMAINS THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS PRIOR TO SUBMISSION OF A BID AND TO THE COMMENCEMENT OF ANY WORK. ANY DISCREPANCIES FOUND BETWEEN WHAT IS SHOWN ON THE DRAWINGS AND THE EXISTING FIELD CONDITIONS SHALL BE BROUGHT TO THE ATTENTION OF THE GENERAL CONTRACTOR OR LOWE'S PROJECT MANAGER TO DETERMINE WHAT ACTION SHOULD BE TAKEN. 0 0 REVISIONS OPRE-BID SET A POST BID SET ISSUE DATE ISSUE DATE DATE DESCRIPTION NEW ROOF CURB NOTES: 1. MECHANICAL CONTRACTOR SHALL PURCHASE AND COORDINATE THE INSTALLATION OF ALL HVAC ROOFTOP UNIT CURBS, EXCEPT EXHAUST FAN CURBS, AND SHALL VERIFY THE EXACT LOCATIONS BASED ON SUPPLIER OF HVAC EQUIPMENT PRIOR TO INSTALLATION. PRECISE LOCATION IS REQUIRED TO MAINTAIN COORDINATION WITH OTHER TRADES. 2. THE MECHANICAL CONTRACTOR SHALL CONTACT CURB SUPPLIER USING INFORMATION PROVIDED ON SHEETS M1.00 AND M4.00. 3. MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR MOVING AND REPLACING ALL CURBS, DECKING, AND EQUIPMENT OF OTHER TRADES THAT RESULT FROM ANY CURBS NOT PROPERLY LOCATED ACCORDING TO THE REQUIREMENTS INDICATED BY THESE DRAWINGS. STRUCTURAL CURB 5/8"x6" BOLT W/2" FENDER WASHER METAL ROOF DECK STEEL ROOF JOIST • INSULATION ROOF CURB SECURED® TO STEEL DECK TO MEET ALL LOCAL CONDITIONS. FLASH CURB AS SHOWN. 07.10.18 0 0 2" FENDER WASHER WITH LOCKWASHER, HEX NUT AND LOCKNUT. SECTION VIEW 5/8"x6" BOLT W/2" FENDER WASHER ON TOP AND BOTTOM OF JOISTS (TYPICAL OF. 4) 1/4" •SELF -TAPPING SHEET METAL.SCREWS AT 12" O.C. (TYPICAL) PLAN VIEW NEW•CURB FASTENING.:DETAIL.. NOTES:. 1: MECHANICAL CONTRACTOR SHALL RECONNECT EXISTING GAS PIPING, IF APPLICABLE TO.NEW UNITS PROVIDING ADJUSTMENTS AND ADAPTERS AS REQUIRED - PAINT AS REQUIRED. 2. MECHANICAL CONTRACTOR SHALL CONNECT NEW DUCT DROP DIFFUSERS TO NEW UNITS. PROVIDING ADJUSTMENTS AND ADAPTERS AS REQUIRED. 3. • MECHANICAL CONTRACTOR SHALL PROVIDE A 1"x1" WIRE GRID THAT IS AT LEAST THE SAME SIZE.AS THE DUCT OPENING FROM THE ROOF TOP UNIT FOR THE RETURN AIR ASSEMBLY. CONTRACTOR SHALL VERIFY THAT DROPBOX AND DUCT TRANSITIONS ARE COATED PER SPECIFICATION SECTION 15733 PRIOR TO INSTALLATION. CONTRACTOR SHALL USE PPG -90-811 PURE WHITE, AS NEEDED FOR TOUCH UP AFTER INSTALLATION. MECHANICAL CONTRACTOR SHALL PROVIDE AND INSTALL A PROPERLY SIZED P -TRAP; A CLEANOUT PLUG AS SHOWN, ANDA 90°TURNDOWN AS SHOWN. PIPE TO THE LOW SIDE OF THE UNIT AND STRAP CONDENSATE TO BASE RAIL AS SHOWN. CONNECT TO EXISTING CONDENSATE PIPING SYSTEM SECURE WITH Y4" SELF -TAPPING SHEET METAL SCREWS REPLACEMENT ROOFTOP UNIT (TYPICAL) NEW P -TRAP & CLEANOUT /// /////// MECHANICAL CONTRACTOR MUST REMOVE AND REPLACE ALL EXISTING SUPPLY AND RETURN DUCT AS WELL AS DROPBOX DIFFUSER. INSTALL ADB -1 WITH DUCT TRANSITIONS, REFER TO SPEC. SECTION 15733. EXISTING RETURN AIR DROP EQUIPMENT GAS LINE CONNECTION EXISTING UNION TYP. EXISTING GAS SUPPLY EXISTING SHUTOFF VALV EXISTING SUPPLY AIR DROP 2 SCALE: NTS LOWE'S HOME CENTERS, INC: 1605 CURTIS BRIDGE ROAD. REEC DOCK ... :WILKESBORO,..NC.28697........ 336.658.4000 M 336.658.7138 (F) • THIS DRAWINl3 IS THE PROPERTY OF LOWE'S HOME CENTERS; U.C. ANY USE OR REPRODUCTION IN WHOLE OR PART IS PROHIBITED WITHOUT THE EXPRESSED " .. WRITTEN CO1I$ENTOF LOWE'3 HOME CENTERS, INC. • OHT2D18 M.L RIGHTS RESERVED, 0 REVIEWED FOR CODE COMPLIANCE APPROVED OCT 102018 City of Tukwila BUILDING DIVISION SLOTTED ANGLE INSTALLED TO SECURE THE SUPPLY AIR AND RETURN AIR DROPS .r --CURB ADAPTER (REFER TO STRUCTURAL PLANS FOR DETAILS OF ROOF CURB INSTALLATION) //2/)////////// //X 0a•D�aUmC�.b•D6a0mOoSoSSOa ee e•Oi "oa°•°°oe•eee$etr. �ruomao$meocn°amnmumioa"a a°°a•e'ee"ee- 8 mat,$8a= m8� RETURN AIR DUCT SUPPLY AIR TRANSITION JL INSTALLING CONTRACTOR SHALL COORDINATE ANY REQUIRED SPRINKLER HEAD RELOCATIONS DUE TO HVAC DROP DIFFUSER INSTALLATIONS WITH A QUALIFIED FIRE PROTECTION CONTRACTOR.. • RECE1V CITY OF TU. SEP 26 NOTE: . pp�I STORES THAT ARE EQUIPPED WIIP EXISTING 4 -WAY DIFFUSERS ARE NOT TO BE REPLACED UNLESS DAMAGED. CONTRACTOR SHALL VERIFY EXISTING CONDITIONS. STORES THAT HAVE THE COMBINATION SUPPLY/RETURN DROPS SHALL BE REPLACED WITH THE NEW SA 4 -WAY DIFFUSERS AND RA DUCT. 0 W I L A 018 CENTER INSTALL SLOTTED ANGLE FROM BAR JOIST TO BAR JOIST ON BOTH SIDES OF RETURN AIR DROP. SCREW TO THE RETURN AIR DROP. INSTALL SLOTTED ANGLE ON TWO SIDES OF SUPPLY AIR DROP AS SHOWN. SECURE THESE ANGLES TO THE ANGLES THAT WERE INSTALLED FOR THE RETURN AIR DROP. THEN SCREW THESE ANGLES TO THE SUPPLY AIR DROP. MECHANICAL CONTRACTOR TO PAINT NEW SUPPLY, RETURN DUCTWORK AND BOTTOM OF CURB ADAPTER (IF EXPOSED TO SALES FLOOR) TO MATCH EXISTING DROP BOX MUST BE TOUCHED UP AFTER INSTALLATION. (USE PPG90-811 PURE WHITE) 1%"x23/8", 14 GAUGE, SLOTTED ANGLE, INSTALLED WITH 2%" LEG TURNED DOWN. B -LINE SA276, OR EQUAL %8" THREADED ROD INSTALLED BETWEEN SLOTTED ANGLE AND DIFFUSER SUPPORT TAB AT ALL FOUR CORNERS. TYP. HIGH WIND RTU ATTACHMENT DETAIL SCALE: 04. NTS COLUMN SENSOR MOUNTING DETAIL SCALE: 03. NTS OFFICE WALL SENSOR MOUNTING DETAIL SCALE: 02 NTS REPLACEMENT ROOF TOP UNIT DETAIL SCALE: • • J W 0 <t 2 • STORE NUMBER: 0010 ORIGINAL ISSUE DATE: PERMIT SET ISSUE DATE: DRAWING NUMBER: 01 M2.0 NTS • NEW DIFFUSERS IS A AND GRILLES REPLACEMENT LENNOX • PACKAGED ROOFTOP UNITS - EQUIPMENT SCHEDULE • °cE'ATHIS RENECESSARILYU ED ON THEDRAWINGSSYMBOLS, DESCRIPTION FINISH APPROVED MAKES/MODEL MARK • PRIMARY SERVICE AREA NOVAR ' CONTROL RTU NAME • TONS OA SYSTEM VENTILATLON EFFICIENCY: PROVIDE WITH MULTI -STAGE AIR VOLUME FACTORY INSTALLED SMOKE DETECTOR HUMIDITROL CORROSION PROTECTION HAIL GUARDS OA CFM MAXIMUM SETTING SEE VENT SCHEDULE SCHEDULE DESIGN CONDITIONS AIR FLOW ..' 11,478. HEATING ELECTRICAL LENNOX • TONS MARK SUMMER OUTDOOR SUMMER INDOOR WINTER OUTDOOR WINTER INDOOR SUPPLY MOTOR HP TSP IN. EFFICIENCY FUEL GAS INPUT MBH ELEC HEAT KW OUTPUT MBH HEAT OPTION VOLT PHASE MIN CIR AMP. MOCP MODEL # SLANT FACE DROP DIFFUSER (17.5 TO 20 TON) ALUMINUM WITH FACTORY BAKED WHITE FINISH AES INDUSTRIES, INC. ADB -1 20-4 SLANT FACE DROP DIFFUSER (25 TON) ALUMINUM WITH FACTORY BAKED WHITE FINISH AES INDUSTRIES, INC. ADB -1-25-4 RTU01 SALES FLOOR - PERIMETER SFP-01 17.5 0:8 YES RA NO YES NO 2,170 82 DB 64 WB 75/50% DB/RH 25 DB 70 DB 7,000 5 .4 14.0 IEER GAS 260 N/A 208 STANDARD 480/3 39 45 LGH 210 H4M SxG 17.5 RTU01 SLANT DROP DIFFUSERER (1 (12.5 TON) ALUMINUM WITH FACTORY BAKED WHITE FINISH ' • AES INDUSTRIES, INC. ADB -1-12-4 RTUO2 RECEIVING REC-02 20 OFFICES YES RA NO YES NO 1,478 82 DB 64 WB 75/50% DB/RH 25 DB 70 DB 8,000 5.0 .4 14.5 LEER GAS 260 N/A 208 STANDARD 480/3 50 50 LGH 240 H4M SxG 20 RTUO2 . SLANT FACE DROP DIFFUSER (10 TON) ALUMINUM WITH FACTORY BAKED WHITE FINISH AES INDUSTRIES, INC. ADB -1-10-4 RTUO3 SALES FLOOR - PERIMETER SFP-03 17.5 12 YES RA NO YES NO 2,170 82 DB 64 WB 75/50% DB/RH 25 DB 70 DB 7,000 5 .4 14.0 IEER GAS' 260 N/A 208 STANDARD 480/3 39 45 LGH 210 H4M SxG 17.5 RTUO3 RTUO4 SALES FLOOR - INTERIOR SFP-04 17.5 45 YES RA NO YES NO - 2,170 82 DB 64 WB 75/50% DB/RH 25 DB 70 DB 7,000 5 .4 14.0 IEER GAS 260 N/A 208 STANDARD 480/3 39 45 LGH 210 H4M SxG 17.5 RTUO4 4 -WAY SUPPLY AIR 24"x24" CEILING LAY -IN ALUMINUM WITH BAKED WHITE FINISH - TITUS MODEL TDC-3 WITH ROUND COLLAR - TUTTLE & BAILEY "M" WITH ROUND COLLAR - PRICE MODEL SMD WITH ROUND COLLAR -KRUEGER MODEL SHR4-F23 WITH ROUND COLLAR - METAL*AIRF MODEL 5500S WITH ROUND COLLAR RTUO5 SALES FLOOR - INERIOR SFP-05 17.5 YES RA NO YES NO 2,170 82 DB 64 WB 75/50% DB/RH 25 DB ' 70 DB 7,000 5 .4 14.0 IEER GAS 260 N/A 208 STANDARD 480/3 39 45 LGH 210 H4M SxG 17.5 RTUO5 RTUO6 SALES FLOOR - PERIMETER SFI-GFC-06 17.5 YES RA NO YES NO 2,170 82 DB 64 WB 75/50% DB/RH 25 DB 70 DB 7,000 5 .4 14.0 IEER GAS 260 N/A 208. STANDARD 480/3 39 45 LGH 210 H4M SxG 17.5 RTUO6 RTUO7 SALES FLOOR - PERIMETER SFI-07 17.5 YES . RA NO YES NO 2,170 82 DB 64 WB • 75/50% DB/RH 25 DB 70 DB 7,000 5 .4 14.0 IEER GAS 260 NIA 208 STANDARD 480/3 39 45 LGH 210 H4M SxG 17.5 RTUO7 RETURN OR TRANSFER 24"x24" CEILING LAY -IN ALUMINUM WITH 112"x1/2" EGGCRATE GRID - TITUS MODEL 50 - F - TUTTLE & BAILEY CRE500 - PRICE MODEL 80 - KRUEGER MODEL EGC - 5. - METAL*AIRE MODEL CC -5 RTU08 SALES FLOOR - PERIMETER SFP-08 3 N/A RA NO YES NO 372 82 DB 64 WB 75/50% DB/RH 25 DB 70 DB 1,200 0.5 .6 17.0 SEER ELECT N/A 7.5 N/A ELECTRIC 480/3 15 15 LCH 036 H4E CxG 3 RTU08 RTUO9 FRONT MEZZANINE & OFFICES SFI-09 3 N/A RA YES YES NO 189 '82 DB 64 WB 75/50% DB/RH 25 DB 70 DB 1,200 .5 .4 12.7 EER GAS 65 N/A 52 STANDARD _ 480/3 12 15 LGH 036 H4T SxG 3 . RTUO9 RTU10 FRONT MEZZANINE & OFFICES SFI-10 . 5 N/A RA YES YES NO 116 82 DB 64 WB 75/50% DB/RH 25 DB 70 DB 2,000 1.0 1.0 12.8 IEER ELECT N/A 15 N/A . ELECTRIC 480/3 28 30 LCH 060 H4E ExG 5 RTU10 1. NECK SIZE OF DIFFUSER SHALL BE SAME SIZE AS DUCT SERVING DIFFUSER. 2. FURNISH COLLARS AS REQUIRED TO TIE-IN THE DUCT. 3. SUPPORT DIFFUSERS FROM ROOF STRUCTURE. RTU11 FRONT MEZZANINE & OFFICES . SFI-11 5 N/A RA YES YES NO 422 82 DB 64 WB 75/50% DB/RH 25 DB 70 DB 2,000 1 1.0 12.8 EER GAS 108 N/A 86 MEDIUM 480/3 15 20 LGH 060 H4T MxG • 5 RTU11 RTU12 FRONT MEZZANINE & OFFICES SFI-12 4 N/A RA YES YES NO 108 82 DB 64 WB 75/50% DB/RH . 25 DB 70 DB 1,600 .75 1.0 12.8 EER . GAS 65 N/A 52 STANDARD 480/3 14 15 LGH 048 H4T SxG 4 RTU12 • RTU13 FRONT MEZZANINE & OFFICES SFI-13 5 • N/A RA YES YES NO 398 82 DB 64 WB 75/50% DB/RH 25 DB 70 DB 2,000 1.0 1.0 12.8 IEER ELECT N/A 75 N/A ELECTRIC 480/3 16 20 LCH 060 H4E CxG • 5 RTU13 RTU14 FRONT MEZZANINE & OFFICES SFI-14 5 N/A RA . . YES YES NO 180 82 DB 64 WB 75/50% DB/RH 25 DB 70 DB 2,000 1.0 1.0 12.8 . IEER ELECT N/A 15 N/A ELECTRIC 480/3 28 30 LCH 060 H4E ExG 5 . RTU14 RTU15 FRONT MEZZANINE & OFFICES SFI-15 3 N/A RA YES YES NO 193 82 DB 64 WB 75/50% DBIRH 25 DB 70 DB 1,200 .5 .4 12.7 EER GAS 108 N/A 86 MEDIUM 480/3 12 15 LGH 036 H4T MxG 3 RTU15 RTU16 TELEPHONE ROOM TCMP-16 3 N/A RA YES YES NO 193 82 DB 64 WB 75/50% DB/RH 25 DB ' 70 DB 1,200 .5 .4 12.7 EER GAS 108 N/A 86 MEDIUM 480/3 12 15 LGH 036 H4T MxG 3 RTU16 RTU17 SALES FLOOR - PERIMETER • SFP-17 13 YES RA NO YES NO 1,612 82 DB 64 WB 75/50% DB/RH 25 DB 70 DB 5,200 3.0 .4' 14.1 IEER GAS 169 N/A 135 LOW . 480/3 31 35 LGH 156 H4M LAG 13 RTU17 RTU18 FRONT MEZZANINE & OFFICES SFI-18 4 N/A RA YES YES NO 139. 82 DB 64 WB 75/50% DB/RH 25 DB 70 DB 1,600 .75 1.0 • 12.8 IEER ELECT N/A 15 N/A ELECTRIC 480/3 27 30 LCH 048 H4E ExG 4 RTU18 RTU19 SALES FLOOR - PERIMETER SFI-GFC-19 6 ' YES RA NO YES NO 744 82 DB 64 WB 75/50% DB/RH 25 DB 70 DB 2,400 1.0 1.0 16.0 IEER ELECT N/A 7.5 . N/A ELECTRIC 480/3 15 20 LCH 074 H4E CxG 6 RTU19 RTU20 • SALES FLOOR - PERIMETER SFI-20 10 YES RA NO YES NO 1,240 82 DB 64 WB 75/50% DB/RH 25 DB 70 DB 4,000 2.0. .4 14.0 IEER ELECT N/A 15 N/A ELECTRIC 480/3 27 30 LCH 120 H4M ExG 10 RTU20 RTU21 SALES FLOOR - PERIMETER SFI-GFC-21 6 YES RA NO YES NO 744 82 DB 64 WB 75/50% DB/RH 25 DB 70 DB 2,400 . 1.0 1.0 16.0 IEER ELECT N/A 7.5 N/A ELECTRIC 480/3 15 20 LCH 074 H4E CxG 6 RTU21 .. NOTES: UNITS ARE REPLACING THE EXISTING UNITS IN THE SAME LOCATIONS. ' MODEL NUMBERS SHOWN HERE MAY BE SUBSTITUTED ONLY UPON WRITTEN AUTHORIZATION OF LOWE'S ENGINEERING DEPARTMENT. STATIC PRESSURE SHOWN HERE ACCOUNTS ONLY FOR THE DUCTWORK AND GRILLES. ALL OTHER STATIC PRESSURE COMPONENTS INCLUDING UNIT CABINET, FILTERS, ECONOMIZER, WET COIL, AND HEATING SECTIONS MUST BE INCLUDED BY THE MANUFACTURER FOR SELECTING EVAPORATOR FAN HORSEPOWER: ZONE LEGEND: (POS) - POINT OF SALE -MAIN ENTRANCE/EXIT UNITS: (GCE) - GARDEN CENTER FRONT: (SFI) SALES FLOOR INTERIOR: (GCR) - GARDEN CENTER REAR: (LBRF) - LUMBER FRONT: (LBRR) - LUMBER REAR: (REST) - RESTROOMS: (TRNG) - TRAINING: (PPU) - PRODUCT PICKUP: (VEST) - VESTIBULE: (BRK) - N! EROOM. . 1. THESE 2. THE 3. EXTERNAL 4. CONTROL B REAKR DUCT SMOKE 'DETECTOR:NOTES• 1.: DUCT SMOKE DETECTORS WILL BE FACTORY SUPPLIED; AND FACTORY INSTALLED; WITHIN THE NEW. ............ REPLACEMENT RTU. 2 MECHANICAL CONTRACTOR SHALL COORDINATE WITH THE FIRE ALARM CONTRACTOR FOR THE::..... DE -ENERGIZING AND REMOVAL OF THE EXISTING 24 POWER FOR THEEXISTING DUCT SMOKE DETECTORS. . . 3 MECHANICAL CONTRACTOR.S HALL CONFIRM THE LOCAT'ION OF THE DUCT SMOKE DETECTOR (SUPPLY AND/OR RETURN) WITH LOCAL AHJ AND RELOCATE WITHIN THE ROOF TOP UNIT, IF NEEDED. 4. THE MECHANICAL CONTRACTOR. SHALL PROVIDE (2) 18/4 FPL FIRE CABLE FROM THE INTEGRALLY" MOUNTED DUCT SMOKE DETECTOR TO BELOW ROOF. CABLES ARE TO BE IDENTIFIED AND COILED UP IN THE UNIT AND BELOW THE ROOF DECK. CABLES SHALL EACH HAVE AN ADDITIONAL 8' LENGTH COILED UP FOR FINAL CONNECTIOIN BY ALARM VENDOR. ANY RTU UNIT ABOVE THE REAR OFFICES OR "LIGHTING CLOUD" SHALL HAVE A 25' LENGTH UNCOILED. CABLE LEFT BELOW THE ROOF DECK. ALL CABLES ABOVE THE "LIGHTING CLOUD" SHALL BE PULLED TO THE NEAREST COLUMN OUTSIDE OF "LIGHTING CLOUD" FOR RECONNECTION BY THE ALARM VENDOR. ALL CABLES SHALL BE LABELED WITH REGARD TO "ALARM" AND/OR "REMOTE TEST'. IF SITE HAS REMOTE TEST SWITCHES 18/4 SHALL BE PULLED DOWN THE COLUMN OF THE THERMOSTAT FOR RECONNECTION. THE CABLE COILS SHALL BE TEMPORARILY SECURED TO THE ROOF JOISTS. 5. ALL OTHER WIRING TO THE SMOKE DETECTOR(S) INCLUDING MONITERING AND GLOBAL SHUTDOWN SHALL BE PROVIDED AND INSTALLED BY THE FIRE ALARM CONTRACTOR. . 6. FOR LOCATION OF DUCT SMOKE DETECTOR(S), SEE "NEW LENNOX PACKAGED ROOFTOP UNITS - EQUIPMENT SCHEDULE" ON THIS SHEET. A iOL 1.a,2Dad r.1 `:• • 6 : 7:'v• •MECHANICAL 'CODE VENTILATION REQUIREMENTS UNITS' AREA • VENTILATION . OCCUPANCY: OCCUPIED SQ, FT.. ' OUTDOOR AIR RATE (CFM/FT2). :MIN.' OA CFM BY .: AREA . ACTUAL #PEOPLE JUL PEOPLE OA' AIR RATE ' .(CFM/PERSON) A s 20 1,, CFM BY ACTUAL OCCUPANTS OA: SUBTOTAL OA SYSTEM VENTILATLON EFFICIENCY: CORRECTED REQUIRED :' OUTDOOR AIR CFM .. . SA CFM :. . OA OF SA R . 01 03 TO 68;17;19,20,21 TU SALES FLOOR ' ..SALES . ' 95 654. .12 .. ..' 11,478. 400. -e. 7.5 , 3;000.... • .14;478 .... - OA 18;098. 59 000 : , 31% 31 /o RTUO2 ..,.. RECEIVING; SHIPPING & RECEIVING NING9,86. .12. 1;18. 3 N NA NA 1,183 08 1478'. 10,000 15% . RTUO9 ' OFFICES OFFICE/CONFERENCE 1,600. .. .06 96 11 . ' : ' ::: ' . '5 . 55. : 151 0:8 189 1,200 16% RTU.I/ .. - OFFICES OFFICEICONFERENCE' 800 .06' ° .48 9 .... 5 45 . : ' .. 93 0:8 116 2,000. 6% RTUI1 OFFICES OFFICE/CONFERENCE 4,800 .06 288 10 5 50 338 0.8 422 3,000 14% RTU12 OFFICES OFFICE/CONFERENCE 600 .06 36 10 5 50 86 0.8 108 1,600 7% RTU13 OFFICES OFFICE/CONFERENCE 2,500 .05 288 6 5 30 318 0.8 398 3,000 13% RTU14 OFFICES OFFICE/CONFERENCE 1,400 .06 84 12 5 60 144. . 0.8 . 180 2,000 9% RTU15 OFFICES OFFICE/CONFERENCE 1,400. .06 84 14 . 5 70 154 0.8 193 1,200 16% RTU16 OFFICES OFFICE/CONFERENCE 1.,100 ,06 . 66 9 5 45 111 0.8 139 • 1,200 12% RTU18. OFFICES OFFICE/CONFERENCE 1,100 .06 66 9 5 45 111 0.8 139 1,200 12% NOTES: 1. SET OA DAMPER TO ZERO MINIMUM CFM (UNOCCUPIED MODE), CO 2 SENSORS WILL BE USED TO BRING IN OUTSIDE AIR AS REQUIRED BY THE ACTUAL OCCUPANT LOAD.. 2. CO2 SENSOR'S WILL BE IMPLEMENTED TO CONTROL THE VENTILATION REQUIREMENT IN ALL RTUS EXCEPT RTU -9 thorough 18, AS ALLOWED BY 2012 IECC SECTION C403.2.5.1 AND ASHRAE 62.1 (6.2.7.1), THE MINIM®IEE REQUIRED OUTSIDE AIR WILL BE ADJUSTED USING CO 2 SENSORS. THE MINIMUM BUILDING VENTILATION CALCULATIONS ARE SHOWN USING THE METHOD SHOWN IN THE 2013 ASHRAE STANDARD 62.1. THE AMBIENT CO2 LEVELS ARE ASSUMED TO BE 400 -PPM AND THE DCV SETPOINT IS 950 -PPM MINIMUM AND 1,450 PPM MAXIMUM. DURING OCCUPIED MODE MINIMUM OA THRU RTUS SHALL MEET "MIN. OA CFM BY AREA." + REVIEWED F R(EVIEWE LI .,. APPROVE GENERAL NOTES MECHANICAL EQUIPMENT NOTES 1. ALL MECHANICAL WORK SHALL COMPLY WITH THE LATEST EDITION OF THE LOCALLY ADOPTED MECHANICAL CODE INCLUDING ALL AMENDMENTS AND SHALL COMPLY WITH ALL LOCAL, STATE, AND FEDERAL CODES AND ORDINANCES. 2. ALL WORK SHALL BE PERFORMED BY QUALIFIED TECHNICIANS EXPERIENCED IN THE TRADE. ALL WORK SHALL BE CONSTRUCTED AND INSTALLED IN A NEAT AND WORKMAN -LIKE MANNER ACCORDING TO RECOGNIZED TRADE PRACTICES AND ACCORDING TO SMACNA-HVAC DUCT CONSTRUCTION STANDARDS, 1995, 2ND EDITION, OR LATER. 3 THE DRAWINGS ARE SPECIFIC FOR THE LOCATION OF EQUIPMENT, DUCTS, GRILLES, ETC. IT IS THE INTENT OF THESE DRAWINGS AND SPECIFICATIONS THAT COMPLETE MECHANICAL SYSTEMS WILL BE FURNISHED, INSTALLED, TESTED AND READY FOR OPERATION WHETHER OR NOT EVERY ITEM OF EQUIPMENT, ACCESSORY, DEVICE, ETC. IS SHOWN. REFERENCE SHALL BE MADE TO THE FULL DRAWING RAL PLUMBING, FIRE PROTECTION, PACKAGE INCLUDING ARCHITECTURAL, STRUCTURAL, P U O , AND ELECTRICAL DRAWINGS FOR COORDINATION AND POTENTIAL CONFLICTS. THE MECHANICAL CONTRACTOR MAY, WITHOUT EXTRA CHARGE AND ONLY AS NECESSARY MAKE MODIFICATIONS IN THE LAYOUT AS NEEDED TO PREVENT CONFLICTS WITH OTHER TRADES. SUCH CHANGES SHALL NOT AFFECT THE PERFORMANCE OF THE ENGINEER'S DESIGN. FIELD VERIFY ALL DIMENSIONS BEFORE FABRICATING DUCTWORK. 4. STARTERS,COMBINATION STARTERS, CONTACTORS, ETC. FOR MECHANICAL EQUIPMENT SHALL BE PROVIDED BY THE MECHANICAL CONTRACTOR. ALL POWER WIRING AND CONDUIT TO EQUIPMENT TERMINALS SHALL BE. PROVIDED BY THE ELECTRICAL. CONTRACTOR. POWER SHALL BE TURNED ON ONLY UPON EXPLICIT APPROVAL OF THE MECHANICAL CONTRACTOR. 5. DUCT SMOKE DETECTORS (WHEN REQUIRED BY APPLICABLE CODE) FOR ROOFTOP EQUIPMENT SHALL LIED AND FACTORY INSTALLED IN THE RTUS. THE MECHANICAL CONTRACTOR SHALL BE FACTORY SUPPLIED COORDINATE AND VERIFY FIRE AND SMOKE PROTECTION REQUIRED TO MEET LOCAL CODES.THE MECHANICAL CONTRACTOR SHALL INSTALL THE SMOKE DETECTORS IN THE SUPPLY OR.RETURN DROP (AS REQUIRED BY CODE) AND REWIRE THE FAN SHUTDOWN CIRCUIT. 6. ALL NEW ROUND DUCTWORK IN OFFICE AREA SHALL BE WRAPPED WITH 2 -INCH THICK (INSTALLED R -VALUE OF 5.6) FIBER GLASS INSULATION AND FIBER GLASS SCRIM REINFORCED ALUMINUM FOIL. INSULATED FLEX DUCT WILL BE PERMITTED FOR THE NEW COMPUTER ROOM UNIT. ROUND DUCT DIMENSIONS SHOWN ON THESE PLANS INDICATE THE CLEAR INSIDE DIAMETER OF THE DUCT. FOR RECTANGULAR DUCTS, 1-1/2" DUCT LINER (INSTALLED R -VALUE OF 6.3) OR DUCT WRAP WITH 2 -INCH THICK FIBER GLASS INSULATION (INSTALLED R -VALUE OF 5.6 & HAVING A FIBER GLASS SCRIM REINFORCED ALUMINUM FOIL) MAY BE USED. THE RECTANGULAR DUCT DIMENSIONS SHOWN ARE CLEAR METAL DIMENSIONS AND DO NOT INCLUDE THE 1-1/2" LINER. 7. DUCTWORK CONSTRUCTION AND INSTALLATION SHALL BE ACCORDING TO THE MOST RECENTLY PUBLISHED SMACNA STANDARDS. CURVED ELBOWS SHALL HAVE A CENTERLINE NOT LESS THAN 1-1/2 TIMES DUCT DIAMETER OR SHALL HAVE TURNING VANES INSTALLED. PROVIDE BALANCING DAMPERS, TURNING VANES, AIR SCOOPS, SPIN COLLARS AND ANY OTHER ITEM REQUIRED TO PROPERLY BALANCE THE AIR FLOW. • 8. LOWE'S TO.PROVIDE A CERTI.FIED T&B SUBCONTRACTOR WHO SHALL BALANCE AIR TO ALL DIFFUSERS AND FROM ALL EXHAUST GRILLES AS INDICATED BY THE CFM REQUIREMENTS SHOWN ON THE DRAWINGS. 9. ALL REQUIRED SUPPORTS, STRAPS, HANGERS, AND TOUCH-UP PAINTING ON DIFFUSERS AND STRUCTURE ETC. FOR DUCTWORK AND DROP DIFFUSERS SHALL BE THE RESPONSIBILITY OF THE MECHANICAL CONTRACTOR. 10. ALL UNIT CABINETS SHALL BE CLEARLY LABELED IN TWO LOCATIONS WITH 6" HIGH BLACK PAINTED STENCILED CHARACTERS CORRESPONDING TO UNIT #'S ON THE PLANS. (1) VISIBLE ON ROOF FROM THE ROOF ACCESS LADDER ON THE SIDE OF THE UNIT, & (2) VISIBLE FROM SALES FLOOR ON THE BOTTOM OF THE SUPPLY DIFFUSER. THE MINIMUM LETTER HEIGHT IS 6 -INCHES "RTU10" EXAMPLE. 11. INDOOR AIR FILTERS SHALL BE 2 -INCH THICK, HIGH EFFICIENCY PLEATED MEDIA AND SHALL BE REPLACED EVERY TWO WEEKS DURING CONSTRUCTION AND SHALL BE REPLACED ON THE DAY THE BUILDING IS TURNED OVER TO THE OWNER (KEY TURNOVER). 12. THE HVAC UNITS SERVING THIS FACILITY WILL BE CONTROLLED BY A DIRECT DIGITAL CONTROL (DDC) BUILDING MANAGEMENT SYSTEM. THE CONTROLLER WILL BE FURNISHED TO THE OWNER'S SWITCHGEAR SUPPLIER TO BE MOUNTED INSIDE OF THE MAIN SWITCHGEAR CABINETS. 13. INSTALL CO2 SENSORS FOR THE OFFICE HVAC UNITS AT 5'-0" AFF. ALL SENSORS, DUCTWORK, ETC. NECESSARY FOR A COMPLETE WORKING SYSTEM SHALL BE SUPPLIED AND INSTALLED BY THE MECHANICAL CONTRACTOR. CONDUIT AND WIRING SHALL BE FURNISHED AND INSTALLED BY THE ELECTRICAL CONTRACTOR. 14. FASTENING OF ANYTHING TO THE METAL ROOF DECK IS PROHIBITED. ANY CONTRACTOR RESPONSIBLE FOR DRILLING, PUNCHING, OR OTHERWISE PENETRATING THE METAL ROOF DECK (EXCEPT FOR SPECIFIED EQUIPMENT SHOWN IN THESE DRAWINGS) WILL BE REQUIRED TO REPLACE (NOT REPAIR) THE DAMAGED SHEETS AT THEIR EXPENSE. 15. HVAC SUPPLEMENTAL MATERIALS (FLEX DUCT, DUCT LINING, JACKETS, TAPE, TIES, FITTINGS, ETC.) SHALL HAVE AFLAME SPREAD RATING NOT TO EXCEED 25 AND A SMOKE DEVELOPED RATING NOT TO EXCEED 50. 16. AT COMPLETION OF EACH WORKING DAY, THE MECHANICAL CONTRACTOR SHALL CLEAN UP AND REMOVE ALL DEBRIS AND MATERIAL NOT USED. 1. THE MECHANICAL CONTRACTOR SHALL FURNISH AND INSTALL SINGLE PACKAGE COMBINATION AIR-TO-AIR DX MECHANICAL COOLING AND EITHER GAS FIRED HEATING OR ELECTRIC HEAT SYSTEMS (SEE SCHEDULE THIS SHEET) COMPLETE WITH SENSORS, SWITCHES, CONTROLS, ACCESSORIES, AND OPTIONS AS NOTED BELOW AND/OR AS INDICATED ELSEWHERE ON THE DRAWINGS OR IN THE SPECIFICATIONS. THE EQUIPMENT SHALL BE SHIPPED COMPLETELY FACTORY ASSEMBLED, PIPED, RE -CHARGED, AND WIRED INTERNALLY READY FOR FIELD CONNECTIONS. MANUFACTURER SHALL TEST OPERATE EACH UNIT AT THE FACTORY BEFORE SHIPMENT. ALL ELECTRICAL COMPONENTS SHALL BE U.L. LISTED AND APPROVED. ALL WIRING SHALL COMPLY WITH THE N.E.C. 2. EACH NEW UNIT SHALL BE FACTORY -EQUIPPED WITH AN M3 PRODIGY BOARD AND BACNET BOARD OR A CUSTOM CONTROLLER AS SPECIFIED BY THE OWNER. 3. EACH UNIT, UNLESS NOTED OTHERWISE, SHALL BE EQUIPPED WITH A FACTORY DESIGNED, MOUNTED, CALIBRATED, TESTED AND INSTALLED ECONOMIZER ASSEMBLY INCLUDING MECHANICALLY LINKED OUTSIDE/ E URNN AIR LOW -LEAKAGE DAMPERS, OUTDOOR AIR HOOD WITH CLEANABLE AIR FILTER AND MOISTURE ELIMINATOR AND FULLY MODULATING DAMPER MOTOR WITH SPRING RETURN. A BAROMETRIC RELIEF DAMPER SHALL BE FACTORY -INSTALLED ON EACH UNIT TO RELIEVE POSITIVE BUILDING PRESSURE DURING ECONOMIZER OPERATION. 4. EACH UNIT SHALL HAVE INDOOR AIR FILTER RACKS WITH NEW 2 -INCH THICK, HIGH EFFICIENCY PLEATED FILTERS INSTALLED. FILTERS SHALL BEAR THE LABEL OF AN APPROVED AGENCY. 5. .PROVIDE HAIL GUARDS FOR PROTECTION OF OUTDOOR COILS ON ALL UNITS PER ROOF TOP UNIT EQUIPMENT SCHEDULE ABOVE. 0 0 REVISIONS. OPRE -SID SET A POST BID SET ISSUE DATE ISSUE DATE DATE DESCRIPTION • 07.10.18 0 0 U1 E"+ z. tnZ 0 leg LOWE'S HOME CENTERS,: INC. . : 1605 CURTIS BRIDGE ROAD • REEC DOCK'.. WILKESBORO, NC 28697 (V) 336.658.7138 F) THISIiRAWINO.IS THE PROPERTY OF LOWE'S HOME CENTERS.LLC. ANY OSE OR REPRODUCTION IN WHOLE OR PART IS PROHIBITED WITHOUT THE EXPRESSED WRITTEN CONSENT OF LOWE'S HOME CENTERS, INC. COPYRIGHT 2015 ALL RIGHT'S RESERVED OR INCE OCT 102010 City of Tukwila BUILDING DIVISION 8. EACH UNIT SHALL BE FURNISHED WITH A REMOTE SPACE TEMPERATURE SENSOR. AL. , MECHANICAL CONTRACTOR SHALL PROVIDE THE APPROPRIATE QUANTITY OF CO2 SENSORS FOR REMOTE MOUNTING BY THE MECHANICAL CONTRACTOR. 9. HEAT EXCHANGERS SHALL BE GUARANTEED FOR AT LEAST TEN YEARS. COMPRESSORS SHALL BE GUARANTEED FOR AT LEAST FIVE YEARS. ALL OTHER COMPONENTS SHALL BE GUARANTEED FOR AT LEAST ONE YEAR. 10. HVAC EQUIPMENT STARTUP AND COMMISSIONING: ROOFTOP HVAC UNITS SHALL BE STARTED AND COMMISSIONED IN TWO PHASES: PROVIDE COIL CORROSION PROTECTION COATING FOR ALL UNITS LOCATED WITHIN TEN MILES OF THE 11. OCEAN ANDASN PERROOF NOTED 00 TOP UNIT EQUIPMENT SCHEDULE ABOVE. 7. EACH UNIT SHALL HAVE THE FOLLOWING COMPONENTS, ACCESSORIES, AND/OR OPTIONS FACTORY 12. INSTALLED AND TESTED: E:_ vlti1 p 7.1. DIFFERENTIAL PRESSURE SWITCH ACROSS FILTERS (CLOGGED FILTER SWITCH) 72 DISCHARGE AIR TEMPERATURE SENSOR G I + Ir ry F -► 1, E K `'1 7.3. ALL ACCESS PANELS SHALL BE HINGED SO AS TO REMAIN ATTACHED TO THE UNIT DURING R SERVICING OR INSPECTIONS SEP Z 6 2°1"W 7.4. UNIT DISCONNECT FUSED PER EQUIPMENT NAMEPLATE. WIRING TO DISCONNECT SHALL BE THROUGH BASE OF UNIT. WIRING BY ELECTRICAL CONTRACTOR. 7.5. A 110VAC G.F.I. OUTLET FACTORY MOUNTED ON UNIT. WIRING TO THIS OUTLET SHALL BE PERMIT CENT T THROUGH BASE OF UNIT BY ELECTRICAL CONTRACTOR. 7.6. LOW AMBIENT CONTROLS TO ALLOW UNIT OPERATION DOWN TO 20° F. 7.7. FACTORY SUPPLIED AND INSTALLED SMOKE DETECTORS, SEE RTU SCHEDULE FOR LOCATION. SEE DUCT SMOKE DETECTOR NOTES THIS SHEET FOR ADDITIONAL INFORMATION.. THE MECHANICAL CONTRACTOR SHALL HA L CONTRA T R VERIFY THAT ALL UNITS ARE INSTALLED ED COMPLETELY INCLUDING STEL NCL DIN G POWER WIRING, ZONE SENSORS, FANS ROTATE IN PROPER DIRECTION, ECONOMIZER IS OPERATING, AND, THAT THE OVERALL GENERAL OPERATION OF THE UNITS IS SATISFACTORY. EACH UNIT WILL OPERATE IN THE DEFAULT MODE FOR HEATING AND COOLING SET -POINTS ESTABLISHED BY FACTORY SETTINGS. IF UNITS ARE OPERATING PROPERLY THEN THE UNITS MAY BE OPERATED IN THE DEFAULT SETTINGS UNTIL THE BUILDING MANAGEMENT SYSTEM IS COMMISSIONED. THE MECHANICAL CONTRACTOR SHALL COORDINATE THE HVAC STARTUP WITH THE ELECTRICAL CONTRACTOR. ON THE DAY THE HVAC IS STARTED A FACTORY AUTHORIZED, QUALIFIED TECHNICIAN SHALL BE AT THE JOB SITE ALONG WITH QUALIFIED REPRESENTATIVES OF THE MECHANICAL AND ELECTRICAL CONTRACTORS. THE LOWE'S PROJECT MANAGER SHALL BE GIVEN PROPER ADVANCE NOTICE SO THAT THE OWNER MAY COORDINATE THE APPROPRIATE PERSONNEL REQUIRED TO. PERFORM STARTUP OF THE BUILDING MANAGEMENT SYSTEM. ALL COSTS ASSOCIATED WITH THE HVAC STARTUP SHALL BE PAID BY THE MECHANICAL CONTRACTOR. EXCEPT THE COST OF THE OWNER'S STARTUP TECHNICIAN WILL BE PAID BY THE OWNER. THE OWNER WILL PROVIDE AND PAY FOR AN OWNER'S STARTUP AGENT TO PERFORM THE BUILDING MANAGEMENT SYSTEM STARTUP. ALL DEFICIENCIES FOUND IN THE ELECTRICAL AND HVAC INSTALLATIONS WILL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE RESPONSIBLE CONTRACTOR THE RESPONSIBLE CONTRACTOR SHALL REMEDY ALL DEFICIENCIES IMMEDIATELY AND AT THEIR OWN EXPENSE. THE COSTS FOR ANY ITEMS REQUIRED TO BE REMEDIED BY THE OWNER'S STARTUP AGENT ILL BE BACK -CHARGED THROUGH THE MECHANICAL CONTRACTOR. 1Bojo� ER NOTE TO BIDDERS: THESE CONTRACT DOCUMENTS HAVE BEEN DESIGNED AND DRAWN ASSUMING EXISTING BUILDING CONDITIONS MATCH THE ORIGINAL DRAWINGS. IT HOWEVER, REMAINS THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS PRIOR TO SUBMISSION OF A.BID AND TO THE COMMENCEMENT OF ANY WORK. ANY DISCREPANCIES FOUND BETWEEN WHAT IS SHOWN ON THE DRAWINGS AND THE EXISTING FIELD CONDITIONS SHALL BE BROUGHT TO THE ATTENTION OF THE GENERAL CONTRACTOR OR LOWE'S PROJECT MANAGER TO DETERMINE WHAT ACTION SHOULD BE TAKEN. • 0 0 W 0 Z W (� ❑ UJ = J Q ❑ ..- (/) z _ w 00 LU W O 1 co < 8,) z �" O W LL U O� Z 0 W ...I ❑ ❑ O� 0 2 0 0 ul m STORE NUMBER: 0010 ORIGINAL ISSUE DATE: PERMIT SET ISSUE DATE: DRAWING NUMBER: M3.0 0