HomeMy WebLinkAboutPermit M18-0108 - EMBASSY SUITES - SPLIT SYSTEM REPLACEMENTEMBASSY SUITES 15920 WEST VALLEY HWY M18-0108 Parcel No: Address: 1 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 0005800024 Permit Number: 15920 WEST VALLEY HWY Project Name: EMBASSY SUITES Issue Date: Permit Expires On: M 18-0108 1/10/2019 7/9/2019 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: SEATAC HOTEL OWNER LLC 350 W HUBBARD ST STE #250 , CHICAGO, WA, 60654 SONDRA CAMIS 5300 DENVER AVE S , SEATTLE, WA, 98108 ACCO ENGINEERED SYSTEMS INC (CONST) 6265 SAN FERNANDO RD , GLENDALE, CA, 91201 ACCOESI971DU Phone: (425) 787-8525 Phone: (253) 854-8444 Expiration Date: 10/17/2019 DESCRIPTION OF WORK: REPLACE EXISTING 2 -TON SPLIT SYSTEM WITH NEW, LIKE FOR LIKE Valuation of Work: $10,300.00 Type of Work: REPLACEMENT Fuel type: ELECT Fees Collected: $344.08 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2.017 2015 Date: Y—IM 1 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Na Date: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: Readily accessible access to roof mounted equipment is required. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: ***MECHANICAL PERMIT CONDITIONS*** 10: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 11: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL 1 1 CITY OF TUKW.--A Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. 10 g- O �� Project No. Date Application Accepted: �(>( Date Application Expires: f 9 (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address: Tenant Name: 15920 W Valley Hwy Embassy Suites PROPERTY OWNER Name: Sondra Camis Name: Embassy Suites City: Seattle State: WA Zip: 98108 Address: 15920 W Valley Hwy Email: scamis@accoes.com City: Tukwila State: WA Zip: 98188 CONTACT PERSON — person receiving all project communication Name: Sondra Camis Address: 5300 Denver Ave S City: Seattle State: WA Zip: 98108 Phone: (425) 787-8525 Fax: Email: scamis@accoes.com King Co Assessor's Tax No.: 0005800024 Suite Number: Floor: 1St New Tenant: ❑ Yes ..No MECHANICAL CONTRACTOR INFORMATION Company Name: ACCO Engineered Systems Address: 5300 Denver Ave S City: Seattle State: WA Zip: 98108 Phone: (425) 787-8500 Fax: Contr Reg No.: ACCOESI971DU Exp Date: 10/17/2018 Tukwila Business License No.: BUS -0994418 Valuation of project (contractor's bid price): $ 10,300 Describe the scope of work in detail: Replace existing 2 -Ton split system with new, like for like. Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement Fuel Type: Electric 121 Gas ❑ Other: H:\Applications\Forms-Applications On Line\2016 Applications\Mechanical Permit Application Revised 1-4-16.docx Revised: January 2016 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Residential, Nighttime Furnace >100k btu Industrial Floor furnace 2 Suspended/wall/floor mounted heater 57 dB(A) Appliance vent 2 Repair or addition to heat/refrig/cooling system 47 dB(A) Air handling unit 65 dB(A) <10,000 cfin 1 Unit Type Qty Air handling unit Residential, Nighttime >10,000 cfin Industrial Evaporator cooler 2 Ventilation fan connected to single duct 57 dB(A) Ventilation system 2 Hood and duct 47 dB(A) Incinerator — domestic 65 dB(A) Incinerator — comm/industrial 60 dB(A) Unit Type Qty Fire damper Residential, Nighttime Diffuser Industrial Thermostat 2 Wood/gas stove 57 dB(A) Emergency generator 2 Other mechanical equipment 47 dB(A) 60 dB(A) 65 dB(A) Boiler/Compressor Qty 0-3 hp/100,000 btu Residential, Nighttime 3-15 hp/500,000 btu Industrial 15-30 hp/1,000,000 btu 2 30-50 hp/1,750,000 btu 57 dB(A) 50+ hp/1,750,000 btu 2 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-10PM, Monday through Friday and 8AM-10PM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: • Warning devices; • Construction and property maintenance during the daytime hours (7am-10pm); • Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Savt.dra, C vt.i,s4 Date: 08/27/2018 Print Name: Sondra Camis Day Telephone: (206) 787-8525 Mailing Address: 5300 Denver Ave S Seattle WA 98108 City State Zip H:\Applications`.Forms-Applications On Line\2016 Applications\Mechanical Permit Application Revised I-4-16.docx Revised: January 2016 bh Page 2 of 2 egisterReceipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PermitTRAK PAID $344.08 M18-0108 Address: 15920 WEST VALLEY HWY Apn: 0005800024 $344.08 MECHANICAL $330.85 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $231.53 PLAN CHECK FEE R000.322.102.00.00 0.00$66.17 , TECHNOLOGY FEE $13.23 TECHNOLOGY FEE R000.322.900.04.00 0.00 TOTAL FEES PAID BY RECEIPT: R15263 $13.23 :i. $344.08 Date Paid: Monday, August 27, 2018 Paid By: ACCO ENGINEERED SYSTEMS Pay Method: CHECK 007396 Printed: Monday, August 27, 2018 3:16 PM 1 of 1 YSTEM$ INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: Address: 9' '/ 1a1/ Date C lied: Special Instructions: Da Wanted: C fPl_ 7 -Ze.-- lc} p.m t Requester: Phone No: 2 if7? ZS -77 Approved per applicable codes. Corrections required prior to approval. COMMENTS: u/040.4 ,cNL Inspector: Date: G REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit 110 ecru INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: _ E-4/64-451 cl/i 6 Type of Inspec ion: iiirati0die,�yv ri4/4-e. Address: /5'920 /1/et /414‘.."/ /ii Date Called: Special Instructions: .0,--7,4 D to Wanted: / -/q . ,? rt p.m. Requester: JAs43 No: j 2577 206 ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: gd_ rr,1/� pa‘fh*- -T;t_ S/ 05f",cett/=it Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. 2 Ton Convertible Air Handler TEM4A0B24S21 SA REVIEWED FOR CODE COMPLIANCE APPROVED SEP 04 2018 City of Tukwila BUILDING DNVIS'N AUG 2 7 2018 PERMIT CEN tEH TAG: Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning equipment can be hazardous and requires specific knowledge and training. Improperly installed, adjusted or altered equipment by an unqualified person could result in death or serious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. July 2014 TEM4A0B24-SUB-IA-EN lie Ingersoll Rand MANE Outline Drawing 10.15 1.12 ka .M 8.78 Q I.00 TIP MINIMUM UNIT CLEARANCE TABLE t TO SERVICE B COMBUSTIBLE CLEARANCE £ MATERIAL IREOUIRED) (RECOMMENDED) SIDES 0' 2' FRONT 0' 21' BACK 0' 0' INLET DUCT 0' 1' OUTLET DUCT 1'. N/A FOR THE FIRST 3 FT. OF OUTLET DUCT OMEN ELECTRIC HEATERS ARE INSTALLED: 0' AFTER THE FIRST 1 F1. 111-1.11 0 tl 1 4.2 I.33. LJ 3.01 PLCS 2 I.16 PROM DIMENSIONS • t Air Handler Model A B C '" TQ ; ' ks £ . F • • Flow Control Gas Line Braze TEM4A0B24521SA 45.02 18.50 16.50 16.75 4.68 7.33 18.34 TXV 3/4 All dimensions are in Inches 2 TEM4A0B24-SUB-1 A -EN TRAM' Product Specifications MODEL TEM4AOB24S21SA RATED VOLTS/PH/HZ 208-230/1/60 RATINGS(a) See O.D. Specifications INDOOR COIL — Type Plate Fin Rows — F.P.I. 3-14 Face Area (sq. ft.) 4.37 Tube Size (in.) 3/8 Refrigerant Control TXV Drain Conn. Size (in.)(b) 3/4 NPT DUCT CONNECTIONS See Outline Drawing INDOOR FAN — Type Centrifugal Diameter -Width (In.) 9 X 7 No. Used 1 Drive - No. Speeds Direct - 3 CFM vs. in. w.g. See Fan Performance Table No. Motors — H.P. 1 - 1/4 Motor Speed R.P.M. 1075 Volts/Ph/Hz 208-230/1/60 F.L. Amps 1.3 FILTER Filter Furnished? (c) No REFRIGERANT R -410A Ref. Line Connections Brazed TE M4AOB24-SUB-1 A-E N Coupling or Conn. Size — in. Gas 3/4 Coupling or Conn. Size — in. Liq. 3/8 DIMENSIONS H x W x D Crated (In.) 46 x 21 x 24 Uncrated 45-1/8 x 18-1/2 x 21-1/8 WEIGHT Low Shipping (Lbs.) / Net (Lbs.) 116/110 (a) These Air Handlers are A.H.R.I certified with various Split System Air Conditioners and Heat Pumps (AHRI STANDARD 210/240). Refer to the Split System Outdoor Unit Product Data Guides for performance data. (b) 3/4" Male Plastic Pipe (Ref: ASTM 1785-76) (c) Remote filter required. Minimum Airflow CFM TEM4AOB24S21SA Heater Minimum Heat Speed Tap With Heat Pump Without Heat Pump BAYHTR1504BRK, BAYHTR1504PDC, BAYHTR1504LUG, BAYHTR1505BRK, BAYHTR1505PDC, BAYHTR1505LUG Low Low BAYHTR1508BRK, BAYHTR1508PDC, BAYHTR1508LUG, BAYHTR1510BRK, BAYHTR1510PDC, BAYHTR1510LUG, BAYHTR3510LUG Low Low 3 TRANE Heater Pressure Drop Table TEM Air Handler Models Airflow CFM Number of Racks Heater Racks 1 2 3 4 Heater Model No. of Racks Air Pressure Drop - Inches W.G. BAYHTR1504 1 1800 0.02 0.04 0.06 0.14 BAYHTR1505 1 1700 0.02 0.04 0.06 0.14 BAYHTR1508 2 1600 0.02 0.04 0.06 0.13 BAYHTR1510 2 1500 0.02 0.04 0.06 0.12 BAYHTR3510 3 1400 0.02 0.04 0.06 0.12 BAYHTR1515 3 1300 0.02 0.04 0.05 0.11 BAYHTR3515 3 1200 0.01 0.04 0.05 0.10 BAYHTR1519 4 1100 0.01 0.03 0.05 0.09 BAYHTR1520 4 1000 0.01 0.03 0.04 0.09 BAYHTR1521 4 900 0.01 0.03 0.04 0.08 800 0.01 0.03 700 0.01 0.02 600 0.01 0.02 4 TEM4A0B24-SUB-1A-EN 4 TRAM" Performance and Electrical Data 1. See Product Data or Air Handler nameplate for approved combinations of Air Handlers and Heaters. 2. Heater model numbers may have additional suffix digits. Table 1. Air Flow Performance TEM4AOB24S21SA (a) EXTERNAL STATIC (in w.g) AIRFLOW Speed Taps - 230 VOLTS Speed Taps - 208 VOLTS Capacity High Med Low t High Med Low t 0.1 984 903 719 946 827 612 0.2 948 868 694 910 796 589 0.3 906 828 665 868 760 567 0.4 858 781 630 820 717 543 0.5 802 726 588 764 666 513 0.6 735 660 537 697 605 BAYHTR1508BRK BAYHTR1508PDC BAYHTR1508LUG 0.7 651 581 32.0 614 532 5.76 1. Values are with wet coil, no filter, and no heaters 2. CFM Correction for dry coil = Add 3% 3. t = Factory setting (a) For TEM4A0B24S215A, the recommended speed tap is medium at 0.4" external static pressure. Table 2. Electrical Data TEM4AOB24S21SA Heater Model No. No. of Circuits/ Phases 240 Volt 208 Volt Capacity Heater Amps per Circuit Minimum Circuit Ampacity Maximum Overload Protection Capacity Heater Amps per Circuit Minimum Circuit Ampacity Maximum Overload Protection kW BTUH kW BTUH No Heater 1.3 * 2 15 1.3 * 2 15 BAYHTR1504BRK BAYHTR1504PDC BAYHTR1504LUG 1/1 3.84 13100 16.0 22 25 2.88 9800 13.8 19 20 BAYHTR1505BRK BAYHTR1505PDC BAYHTR1505LUG 1/1 4.80 16400 20.0 27 30 3.60 12300 17.3 23 25 BAYHTR1508BRK BAYHTR1508PDC BAYHTR1508LUG 1/1 7.68 26200 32.0 42 45 5.76 19700 27.7 36 40 BAYHTR1510BRK BAYHTR1510PDC BAYHTR1510LUG 1/1 9.60 32800 40.0 52 60 7.20 24600 34.6 45 45 BAYHTR3510LUG 1/3 9.60 32800 23.1 30 30 7.20 24600 20.0 26 30 * = Motor Amps TEM4A0B24-SUB-1A-EN 5 TRANE. Features and Benefits • Painted metal cabinet with captured foil face insulation • 2% or less air leakage • R-4.2 Insulating Value • Multi -Position UP/Down Flow, Horizontal Left /Right • ALL Aluminum Coil with Enhanced Patented Coil Fin • Electric Heaters with polarized plug connections (sold as accessory) • R-410AThermal Expansion Valve • ECM Motor (3.5 — 5 Ton Models ) • Low Voltage Pigtail Connections • Draw Through Design • Horizontal Drain pan • Single Color • Fused 24V Power • 1 year warranty • 10 -year warranty registered • Optional extended warranty available Important: Condensate management kit is required for all 5 ton air handler models installed in downflow applications. Aft LIP CERTIFIED.„ 0 www.ahridireilory.arg Unitary Small AC AHRI Standard 210/240 I� I .I v, rI,11RI 0rii..i CERTIFIED,,, wvuw.ahridirectory.org Unitary Small HP AHRI Standard 2101240 Intertek Trane optimizes the performance of homes and buildings around the world. A business of Ingersoll Rand, the leader in creating and sustaining safe, comfortable and energy efficient environments, Trane offers a broad portfolio of advanced controls and HVAC systems, comprehensive building services, and parts. For more information, visit www.Trane.com. Trane has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. ©2014 Trane TEM4A0B24-SUB-1A-EN 09 Jul 2014 Supersedes TEM4A0B24-SUB-1-EN (June 2014) �II/Ingersoll Rand • Split System Heat Pump 4TWR4024G 1000A CtTkV OF TUK\"IIL,4 AUG 2 7 2018 ?ERMIT CENTER MI /00 I �` -- - - I I Note: "Graphics in this document are for representation only. ctuallyrE—y�,� ay iJlki., - tce." CODE COMPLIANCE APPROVED SEP 0 4 2018 City of Tukwila Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning equipment can be hazardous and requires specific knowledge and training. Improperly installed, adjusted or altered equipment by an unqualified person could result in death or serious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. March 2016 4TWR4024G-SUB-1 A -EN �R7ingersoll Rand. TRANE SERVICE PANEL ELECTRICAL AND REFRIGERANT COMPONENT CLEARANCES PER PREVAILING CODES. TOP DISCHARGE AREA SHOULD BE UNRESTRICTED FOR AT LEAST 1524 15 FEET) ABOVE UNIT. UNIT SHOULD BE PLACED SO ROOF RUN-OFF WATER DOES NOT POUR DIRECTLY ON UNIT, AND SHOULD BE AT LEAST 305 112') FROM WALL AND ALL SURROUNDING SHRUBBERY ON TWO SIDES. OTHER TWO SIDES UNRESTRICTED. ELECTRICAL SERVICE PANEL 22.2 (1/8) DIA. HOLT LOW VOLTAGT 28.6 11-1/6) DIA. 6.0. WIT 22.2 11/6) DIA. HOLE IN CONTRO BOX BOTTOM FOR ELECTRICA POWER SUPPL K 25 11)1 Base A B L 125 Hz F). el 1000 Hz 3 A :'•�+ 111` 3 730 (28-3/4) 829 (32-5/8) 756 (29-3/4) 1 fH I Al� _ -, — 19'i j7-7/4) 60 (2-3/8) 6.0. FOR ALTERNATE — ELECTRICAL ROUTING L10UID LINE SERVICE VALVE, / 'E' I.D. FEMALE BRAZE J CONNECTION WITH I/4' SAE FLARE PRESSURE TAP FITTINGS. GAS LINE 1/4 TURN BALL SERVICE VALVE, 'D' I.D. FEMALE BRAZED CONNECTION WITH 1/4" SAE FLARE PRESSURE TAP FITT NG. Model Base A B c 125 Hz F). Gf 1000 Hz 3 K 4TWR4024G 3 730 (28-3/4) 829 (32-5/8) 756 (29-3/4) , 3/4 j 3/87 (�) 76 (3)2 19'i j7-7/4) 60 (2-3/8) 508 (20) p SOUND POWER LEVEL Model A -Weighted Sound Power Level [dB(A)] Full Octave Sound Power [dB] 63 Hz* 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz 4TWR4024G 71 77 72 68 68 69 60 53 47 Note: Rated in accordance with AHRI Standard 270-2008 *For reference only. 2 4TWR4024G-SUB-1A-EN Product Specifications OUTDOOR UNIT (a) (b) 4TWR4024G1000A POWER CONNS. — V/PH/HZ (c) 208/230/1/60 MIN. BRCH. CIR. AMPACITY 14 BR. CIR. PROT. RTG. — MAX. (AMPS) 25 COMPRESSOR CLIMATUFF®- SCROLL NO. USED — NO. STAGES 1 — 1 VOLTS/PH/HZ 208/230/1/60 R.L. AMPS (d)— L.R. AMPS 10.9 — 62.9 FACTORY INSTALLED START COMPONENTS (e) YES INSULATION/SOUND BLANKET NO COMPRESSOR HEAT NO OUTDOOR FAN PROPELLER DIA. (IN.) — NO. USED 23 — 1 TYPE DRIVE — NO. SPEEDS DIRECT— 1 CFM @ 0.0 IN. W.G. (f) 2675 NO. MOTORS — HP 1 — 1/8 MOTOR SPEED R.P.M. 850 VOLTS/PH/HZ 208/230/1/60 F.L. AMPS 0.64 OUTDOOR COIL — TYPE SPINE FINT" ROWS—F.P.I. 1-24 FACE AREA (SQ. FT.) 16.3 TUBE SIZE (IN.) 3/8 REFRIGERANT CONTROL EXPANSION VALVE REFRIGERANT LBS. — R -410A (O.D. UNIT) (9) 6 LBS., 2 OZ FACTORY SUPPLIED YES LINE SIZE — IN. O.D. GAS (h) (0) 3/4 LINE SIZE — IN. O.D. LIQ. 3/8 CHARGING SPECIFICATIONS SUBCOOLING 10°F DIMENSIONS H X W X D CRATED (IN.) 34 x 33x 30.1 WEIGHT SHIPPING (LBS.) 191 NET (LBS.) 163 (a) Certified in accordance with the Air -Source Unitary Air -conditioner Equipment certification program, which is based on AHRI standard 210/240. (b) Rated in accordance with AHRI standard 270. (c) Calculated in accordance with Nati. Elec. Codes. Use only HACR circuit breakers or fuses. (d) This value shown for compressor RLA on the unit nameplate and on this specification sheet is used to compute minimum branch circuit ampacity and max. fuse size. The value shown is the branch circuit selection current. (e) No means no start components. Yes means quick start kit components. PTC means positive temperature coefficient starter. Optional kit shown. (f) Standard Air — Dry Coil — Outdoor (s) This value approximate. For more precise value see unit nameplate. (h) Reference the outdoor unit ship -with literature for refrigerant piping length and lift guidelines. Reference the refrigerant piping software pub # 32-3312-xx or refrigerant piping application guide SS- APG006-xx for long line sets or specialty applications (xx denotes latest revision). (1) Trane outdoor condensing units are factory charged with the system charge required for the outdoor condensing unit and 15 feet of tested connecting lines. If connecting line length exceeds 15 feet, then final refrigerant charge adjustment is necessary. Each additional foot over 15 feet requires 0.6 ozs of refrigerant. See the Installer's Guide for full charging instructions. 4TW R4024G-SUB-1 A-E N 3 • TRANE Mechanical Specification Options General The Outdoor Units are fully charged from the factory for up to 15 feet of piping. This unit is designed to operate at outdoor ambient temperatures as high as 115°F. Cooling capacities are matched with a wide selection of air handlers and furnace coils that are AHRI certified. The unit is certified to UL 1995. Exterior is designed for outdoor application. Casing Unit casing is constructed of heavy gauge, galvanized steel and painted with a weather -resistant powder paint finish on all louvered panels and the fan top panel. The corner panels are prepainted. All panels are subjected to our 1,000 hour salt spray test . The base is made of a CMBP-G30 weatherproof material to resist corrosion. Refrigerant Controls Refrigeration system controls include condenser fan, compressor contactor and high pressure switch. High and low pressure controls are inherent to the compressor. A factory supplied liquid line drier is standard. Some models may require field installation. C."--"\ lJ7;yr, /iryge Compressor The compressor features internal over temperature, pressure protection and total dipped hermetic motor. Other features include: Centrifugal oil pump and low vibration and noise. Condenser Coil The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by louvered panels. Low Ambient Cooling As manufactured, this system has a cooling capacity to 55°E The addition of an evaporator defrost control permits operation to 40°E The addition of an evaporator defrost control with TXV permits low ambient cooling to 30°E Thermostats—Cooling only and heat/cooling (manual and automatic change over). Sub -base to match thermostat and locking thermostat cover. Evaporator Defrost Control — See Low Ambient Cooling. ETA Intertek US i.�i CERTIFIED,, wwwa h ritli rertnr y nig Unitary Small HP AHRI Standard 210!240 Trane optimizes the performance of homes and buildings around the world. A business of Ingersoll Rand, the leader in creating and sustaining safe, comfortable and energy efficient environments, Trane offers a broad portfolio of advanced controls and HVAC systems, comprehensive building services, and parts. For more information, visit www.Trane.com. Trane has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. 02016 Trane 4TWR4024G-SUB-1A-EN 01 Mar 2016 Supersedes (New) �17/ Ingersoll Rand. ;PERMIT COORD COPY c PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M18-0108 DATE: 08/29/18 PROJECT NAME: EMBASSY SUITES SITE ADDRESS: 15920 W VALLEY HWY X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: Building Division Public Works (6\alft MVI Fire Prevention Structural Planning Division n ❑ Permit Coordinator n PRELIMINARY REVIEW: DATE: 08/30/18 Not Applicable n Structural Review Required (no approval/review required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved DUE DATE: 09/27/18 ❑ Approved with Conditions ri Corrections Required ❑ Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping ❑ PW 0 Staff Initials: 12/18/2013 ACCO ENGINEERED SYSTEMS INC se Washington State Department of Labor & Industries I lame Espanol Contact: Safety & Health Claims & Insurance Search L&I Page 1 of 3 A -Z Index help My t&I Workplace Rights Trades & Licensing ACCO ENGINEERED SYSTEMS INC Owner or tradesperson MARRS, JEFFREY R Principals MARRS, JEFFREY R, PRESIDENT OSIER, ROBERT, SECRETARY PETERSEN, JOHN GORDON, TREASURER KESSLER, ROBERTA A, SECRETARY (End: 02/09/2018) AVERSANO, JOHN PAUL, PRESIDENT (End: 07/17/2017) NARBONNE, PETER HENRY, VICE PRESIDENT (End: 07/17/2017) HANSEN, JOHN WALTER, VICE PRESIDENT (End: 07/17/2017) MCNAMARA, WILLIAM B, VICE PRESIDENT (End: 09/01/2004) VLICK, ROBERT P, VICE PRESIDENT (End: 10/17/2011) RICHTER, CHARLES K, VICE PRESIDENT (End: 10/17/2011) WESTPHAL, KENNETH B, VICE PRESIDENT (End: 10/17/2011) YATES, RICHARD D, VICE PRESIDENT (End: 10/17/2011) GOODMAN, MILTON L, VICE PRESIDENT (End: 10/17/2011) SMITH, STEVEN J, VICE PRESIDENT (End: 10/17/2011) KRASSENSKY, RONALD, VICE PRESIDENT (End: 10/17/2011) HAMMOND, ROBERT T, VICE PRESIDENT (End: 10/17/2011) MARRS, JEFFREY R, VICE PRESIDENT (End: 10/17/2011) LUDOLPH, DOUGLAS E, VICE PRESIDENT (End: 10/17/2011) BROWN, ROBERT A, TREASURER (End: 10/17/2011) BOYSEN, THOMAS C, SECRETARY (End: 11/06/2006) 6265 SAN FERNANDO RD GLENDALE, CA 91201 253-854-8444 Help us improve https://secure.Ini.wa.gov/verify/Detail.aspx?UBI=601003669&LIC=ACCOESI971DU&SAW= 01/10/2019 ACCO ENGINEERED SYSTEMS INC WA UBI No. i Business type 601 003 669 Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Co„tractor License specialties GENERAL License no. ACCOESI971DU • Effective — expiration 03/31/2003-10/17/2019 Bond FIDELITY & DEPOSIT CO OF MD Bond account no. 08030409 Active. Meets current requirements. $12,000.00 Received by L&I Effective date 10/02/2001 10/01/2001 Expiration date Until Canceled Insurance Arch Insurance Co Policy no. 71PKG8949201 Received by L&I 10/02/2018 F. $2,000,000.00 Effective date 10/01/2018 Expiration date 10/01/2019 Insurance history - Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts i No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID 386,261-00 Doing business as ACCO ENGINEERaD SYSTEMS Estimated workers reported Quarter 3 of Year,':018 "Greater than 100 Workers" L&I account contact T2 / SUSAN BETT:; (360)902-4828 - Email: BETT235@lni.wa.gov Account is current. Public Wor'cs Strikes and Debarments Verify the contracts: is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not a;;owed to bid No debarments hove been issued against this contractor. Workplace safety and health Page 2 of 3 Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601003669&LIC=ACCOESI971DU&SAW= 01/10/2019