Loading...
HomeMy WebLinkAboutPermit M18-0113 - KING COUNTY HOUSING AUTHORITY - HEAT PUMPKING COUNTY HOUSING AUTHORITY 14410 41ST AVE S BLDG 1 M18-0113 Parcel No: Address: r� City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 0040000205 Permit Number: M18-0113 14410 41ST AVE S BLDG 1 Project Name: KING COUNTY HOUSING AUTHORITY Issue Date: 11/13/2019 Permit Expires On: 5/11/2020 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: KC HOUSING AUTHORITY 600 ANDOVER PARK W , TUKWILA, WA, 98188 MICHAEL CUADRA 700 ANDOVER PARK W , TUKWILA, WA, 98188 WASHINGTON HEATING & A/C INC 13620 FIRST AVE S , SEATTLE, WA, 98114 WASHIHA012LQ Phone: (206) 574-1219 Phone: (206) 860-3832 Expiration Date: 6/16/2020 DESCRIPTION OF WORK: NEW HEAT PUMP IN ELEVATOR MACHINE ROOM AND CORRESPONDING EXTERIOR UNIT FOR CODE COMPLIANCE Valuation of Work: $20,000.00 Type of Work: NEW Fuel type: ELECT Fees Collected: $466.69 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: 125 Sewer District: VALLEY VIEW Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Date: p ---1,5-7q I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: Mot.) mom- � O fvGi Date: 1) 2 ) P\ This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 4: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 8: ***MECHANICAL PERMIT CONDITIONS*** 9: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 10: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL ACCOUNT QUANTITY PermitTRAK $374.78 M18-0113 Address: 14410 41ST AVE S BLDG 1 Apn: 0040000205 $374.78 PERMIT ISSUANCE BASE FEE PERMIT FEE R000.322.100.00.00 R000.322.100.00.00 0.00 0.00 $323.78 TECHNOLOGY FEE $17.85 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R19060 R000.322.900.04.00 0.00 $17.85 374.78 Date Paid: Wednesday, November 13, 2019 Paid By: WASHINGTON HEATING & AIR CONDI Pay Method: CHECK 22049 Printed: Wednesday, November 13, 2019 9:52 AM 1 of 1 Ir. !/ SYSTEMS CITY OF TUKW.LA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. keop Project No. Date Application Accepted: Date Application Expires: lgc‘ \, (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION King Co Assessor's Tax No.: 004000-0205 Site Address: 14410 41st Ave S Suite Number: Floor: Tenant Name: King County Housing Authority PROPERTY OWNER Name: Michael Cuadra Name: King County Housing Authority City: Tukwila State: WA Zip: 98188 Address: 700 Andover Park W Email: MichaelC@kcha.org City: Tukwila State: WA Zip: 98188 CONTACT PERSON — person receiving all project communication Name: Michael Cuadra Address: 700 Andover Park W City: Tukwila State: WA Zip: 98188 Phone: (206) 574-1219 Fax: Email: MichaelC@kcha.org New Tenant: ❑ Yes ❑✓ .. No MECHANICAL CONTRACTOR INFORMATION Company Name: TBD Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: Valuation of project (contractor's bid price): $ Describe the scope of work in detail: New heat pump in elevator machine room and corresponding exterior unit for code compliance 20,000 Use: Residential: New ❑ Replacement ❑ Commercial: New ❑✓ Replacement ❑ Fuel Type: Electric ❑✓ Gas ❑ Other: H: Applications Forms -Applications On Line 2016 Applications Mechanical Permit Application Revised 1-4-16.docx Revised: January 2016 bh Page 1 of 2 / Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Residential, Nighttime Furnace >100k btu 1 Floor furnace 55 dB(A) Suspended/wall/floor mounted heater 57 dB(A) Appliance vent Commercial Repair or addition to heat/refrig/cooling system 47 dB(A) Air handling unit 65 dB(A) <10,000 cfm 60 dB(A) Unit Type Qty Air handling unit Residential, Nighttime >10,000 cfm 1 Evaporator cooler 55 dB(A) Ventilation fan connected to single duct 57 dB(A) Ventilation system Commercial Hood and duct 47 dB(A) Incinerator — domestic 65 dB(A) Incinerator — comm/industrial 60 dB(A) Unit Type Qty Fire damper Residential, Nighttime Diffuser Industrial Thermostat 55 dB(A) Wood/gas stove 57 dB(A) Emergency generator Commercial Other mechanical equipment 47 dB(A) 60 dB(A) 65 dB(A) Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels ate based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-10PM, Monday through Friday and 8AM-10PM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: Warning devices; • Construction and property maintenance during the daytime hours (7am-lOpm); • Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER UTIHORIZED AGENT: Signature: Print Name: LE.J SETC>: Mailing Address: IDS° N• 'Pall"' SC H: Applications Forms -Applications On Line 2016 Applications Mechanical Permit Application Revised 1-4-16.docx Revised: January 2016 bh Date: 0/31 %t -'of 8 Day Telephone: 2.06 — 61•5 - 9151 "SEA 'iTL v8 W R City State 48103 Zip Page 2 of 2 ash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $980.48 D18-0277 Address: 14410 41ST AVE S BLDG 1 Apn: 0040000205 $888.57 Credit Card Fee $25.88 Credit Card Fee R000.369.908.00.00 0.00 $25.88 DEVELOPMENT $862.69 PLAN CHECK FEE R000.345.830.00.00 0.00 $862.69 M18-0113 Address: 14410 41ST AVE S BLDG 1 Apn: 0040000205 $91.91 Credit Card Fee $2.68 Credit Card Fee R000.369.908.00.00 0.00 $2.68 MECHANICAL $89.23 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R15304 R000.322.102.00.00 0.00 $89.23 $980.48 Date Paid: Friday, August 31, 2018 Paid By: NICHAEL CUADRA Pay Method: CREDIT CARD 096983 Printed: Friday, August 31, 2018 11:05 AM 1 of 1 SYSTEMS Page 1 of 2 CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA 0017340000802374464500 Date: 08/31/2018 11:05:25 AM CREDIT CARD SALE VISA CARD NUMBER: **********8721 K TRAN AMOUNT: $980.48 APPROVAL CD: 096983 RECORD #: 000 CLERK ID: Rachelle X {CARDHOLDER'S SIGNATURE} I AGREE TO PAY THE ABOVE TOTAL AMOUNT ACCORDING TO THE CARD ISSUER AGREEMENT (MERCHANT AGREEMENT IF CREDIT VOUCHER) Thank you! Merchant Copy https ://classic .convergepay.com/VirtualMerchant/transaction.do?dispatchMethod=printTra... 8/31/2018 Page 2 of 2 / CO TUKWILA ETRAKIT 6200 SOUTHCFNTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA Date: 08/31/2018 11:05:25 AM CREDIT CARD SALE VISA CARD NUMBER: **********8721 K TRAN AMOUNT: $980.48 APPROVAL CD: 096983 RECORD #: 000 CLERK ID: Rachelle Thank you! Customer Copy https://c1 as::c. convergepaycom/V irtualMerchant/transaction. do?dispatchMethod=printTra... 8/31 /2018 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Mi8-0113 Project: t l � Aziti MIIed: ype of Inspectio,�_1I 14 rl rima Addre. NNW La AlVl.,.. , _ SpecialInstructions: 3 # 1 Date Wanted: /2-3- Zo t a.m. p.m. Requester: „^�,�,(/,,?�� Phone No: (/ Zoio - 34G -453 a XApproved per applicable codes. Corrections required prior to approval. COMMENTS: 199°-itesto(c41.-- 14.420,C, Inspector: __62 Date:! zO n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 0112' -0)13 Protect: tiv Type ofInspectio � ��. �„/' AddresV l'jello , ate Called: Special Instructions: LRequester: 'Date Wanted: Wane a.m. p.m. Phone No: Approved per applicable codes. 1:1Corrections required prior to approval. OMMENTS: ‘g°6ci tA2 Asep.L,,t.L) Inspector:/ / /Lf 2 0 D.5,5i)e) n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 hti$`- 6113 Project: 06frelscci*Ay pow wisAve Special Instructions: Ault 5. Typof Inspection: -41 Date Called Date Wanted: a.m. `Ng'2015 p.m. Requester: Phone No: G- 5325 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: * 14241/_ Inspector: QC),( , Date/ /Q 2.0. REINSPECTION FEE REQUIRED. Prior to next inspection, fee must bts paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. City of Tukwila Allan Ekberg, Mayor Department of Community Development - Jack Pace, Director August 20, 2019 Lisa Hawkins 700 Andover Park W Suite C Tukwila, WA 98188 RE: Request for Permit Application Extension #2 Permit Number M18-0113 Dear Ms. Hawkins, This letter is in response to your written request for an extension to Application Number M18-0113. The Building Official, Jerry Hight, has reviewed your letter and considered your request to extend the above referenced permit. It has been determined that the City of Tukwila Building Division will be granting an extension to the permit application through March 3, 2020. If you should have any questions, please contact our office at (206) 431-3670. Sincerely, 664,(176W /100 Kandace Nichols Permit Technician File: Permit No. M18-0113 Tukwila City Hall • 6200 Southcenter Boulevard • Tukwila, WA 98188 • 206-433-1800 • Website: TukwilaWA.gov r -- ' King County Housing Authority Capital Construction Department 700 Andover Park West - Suite C * Seattle, WA 98188 August 14, 2019 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, WA 98188 Attn: Kandace Nichols2 RE: Permit Application No. M18-0113 RECEIVED COMMUNITY DEVELOPMENT The project for the permit listed above was scheduled to begin 4/29/19 and complete 6/28/19. Currently, this project is slated to start 9/16/19 and complete 12/19/19. Our extended permit is about to expire, and we would like to request an extension as our final inspection will not occur until 12/19/19. This is an elevator upgrade project where we will be replacing the jack, upgrading finishes and equipment so there will not be any inspections until the end of the project. Please let us know how we can continue to keep the permit active until its scheduled completion. You can contact me via email (lisahana,kcha.org) or phone (206-795-0147), or send written correspondence to the address listed at the top of this memo. erely, Hawkins Project Manager Request for Extension # Current h,: piration Date:14 9 Extension ,Zequest: (.'i Approv 'd for _— _�v ✓--- days L)eniec provide explanation) ( Signatures Initials KC.HACCD/4'.80/U2 25 14 8/5/2019 City of Tukwila Department of Community Development MICHAEL CUADRA 700 ANDOVER PARK W TUKWILA, WA 98188 RE: Permit Application No. M18-0113 KING COUNTY HOUSING AUTHORITY 14410 41ST AVE S Dear MICHAEL CUADRA, Allan Ekberg, Mayor Jack Pace, Director In reviewing our current application files, it appears that your permit applied for on 8/31/2018, has not been issued by the City of Tukwila Permit Center. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or National Electrical Code every permit application not issued within 180 days from the date of application shall expire and become null and void. Currently your application has a status of APPROVED and is due to expire on 9/1/2019. If you still plan to pursue your project, you are hereby advised to do one of the following: 1) If the plan review is complete for the project and your application is approved, you may pick up the application before the date of expiration. At the time of permit issuance the expiration date will automatically be extended 180 days. -or- 2) If the plan review is not completed submit a written request for application extension (7) seven days in advance of the expiration date. Address your extension request to the Building Official and state your reason(s) for the need to extend your application. The Building Code does allow the Building Official to approve one extension of up to 90 days. If it is determined that your extension request is granted, you will be notified by mail. In the event that we do not receive your written request for extension or request is denied, your permit application will expire and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, Kandace Nichols2 Permit Technician File No: M18-0113 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 / l \, City of Tukwila A Allan Ekberg, Mayor Department of Community Development - Jack Pace, Director April 11, 2019 Michael Cuadra 700 Andover Park W Tukwila, WA 98188 RE: Request for Extension #1 Permit Number M18-0113 Dear Mr. Cuadra, This letter is in response to your written request for an extension to Permit M18-0113. The Building Official, Jerry Hight, has reviewed your letter and considered your request to extend the above referenced permit. It has been determined that the City of Tukwila Building Division will be granting an extension to the permit through September 01, 2019. If you should have any questions, please contact our office at (206) 431-3670. Jazzel Salazar Permit Technician File: Permit No. M18-0113 Tukwila City Hall • 6200 Southcenter Boulevard • Tukwila, WA 98188 • 206-433-1800 • Website: TukwilaWA.gov i" N RECEIVED EB 22 20:3 ■ ■ King County Housing Authority Capital Construction Department 700 Andover Park West - Suite C * Seattle, WA 98188 February 19, 2019 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, WA 98188 Attn: Jazzel Salzar RE: Permit Application No. M18-0113 (OMti1l 1N► f Y DI VI 1 c /1 1\11 t i l The project for the permit listed above is scheduled to begin 4/29/19 and complete 6/28/19. Our permit is about to expire, and we would like to request an extension as our final inspection will not occur until 6/28/19. This is an elevator upgrade project where we will be replacing the jack, upgrading finishes and equipment so there will not be any inspections until the end of the project. Please let us know how we can continue to keep the permit active until its scheduled completion. You can contact me via email (lisaha(cikcha.org) or phone (206-795-0147), or send written correspondence to the address listed at the top of this memo. Sincerely, Off' s . Hawkins rd ect Manager Request for Extensio # Current Expiration Date: 3 - 1 SI Extension Request: Approved for / ( C days Denied (provide cNplanation) Signature nitials I CHA-CCD / 4180 / 02 25-14 2/7/2019 City of Tukwila Department of Community Development MICHAEL CUADRA 700 ANDOVER PARK W TUKWILA, WA 98188 RE: Permit Application No. M18-0113 KING COUNTY HOUSING AUTHORITY 14410 41ST AVE S Dear MICHAEL CUADRA, Allan Ekberg, Mayor Jack Pace, Director In reviewing our current application files, it appears that your permit applied for on 8/31/2018, has not been issued by the City of Tukwila Permit Center. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or National Electrical Code every permit application not issued within 180 days from the date of application shall expire and become null and void. Currently your application has a status of APPROVED and is due to expire on 3/1/2019. If you still plan to pursue your project, you are hereby advised to do one of the following: 1) If the plan review is complete for the project and your application is approved, you may pick up the application before the date of expiration. At the time of permit issuance the expiration date will automatically be extended 180 days. -or- 2) If the plan review is not completed submit a written request for application extension (7) seven days in advance of the expiration date. Address your extension request to the Building Official and state your reason(s) for the need to extend your application. The Building Code does allow the Building Official to approve one extension of up to 90 days. If it is determined that your extension request is granted, you will be notified by mail. In the event that we do not receive your written request for extension or request is denied, your permit application will expire and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, Jazzel Salzar Permit Technician File No: M18-0113 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 f 1 PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M18-0113 DATE: 09/05/18 PROJECT NAME: KING COUNTY HOUSING AUTHORITY SITE ADDRESS: 14410 41ST AVE 5 X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: q-11-40 Building Division Public Works OA Q;1 1—f� Fire Prevention Planning Division n Structural ❑ Permit Coordinator ❑ PRELIMINARY REVIEW: DATE: 09/06/18 Not Applicable ❑ Structural Review Required (no approval/review required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved DUE DATE: 10/04/18 ❑ Approved with Conditions Corrections Required ❑ Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW ❑ Staff Initials:__ 12/18/2013 C2) Labor & Industries (https://Ini.wa.gov) Con rac this i WASHINGTON HEATING & A/C INC Owner or tradesperson Principals TRAN, STEVEN c, PRESIDENT LONG, MONTHEA R, VICE PRESIDENT PECH, MAKARA, SECRETARY (End: 05/30/2008) LONG, MAKARA, PRESIDENT (End: 06/17/2008) Doing business as WASHINGTON HEATING & A/C INC WA UBI No. 601 962 099 13620 FIRST AVE S SEATTLE, WA 98168 206-860-3832 KING County Business type Corporation Governing persons MONTHEA R LONG STEVEN TRAN; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active Meets current requirements. License specialties HeatingNent/Air-Conditioning and Refrig (HVAC/R) License no. WASHIHA012L0 Effective — expiration 06/18/1999— 06/16/2020 Bond Developers Surety & Indem Co Bond account no. 252216C $6,000.00 Received by L&I Effective date 05/25/2011 06/16/2011 Expiration date Until Canceled Insurance Ohio Security Ins Co $1,000,000.00 Policy no. BKS53513733 Received by L&I Effective date 05/31/2019 06/16/2011 Expiration date 06/16/2020 Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. ABBREVIATIONS LEGEND DRAWING INDEX S H K S A R C H I T E C T S AC ACU AD AFF APPROX ARCH ASHRAE BDD BFF BTUH CD CFM CIRC CO COND CONT COORD COTG CW DEG DIA DIM DN DWG E EA ELEV, EL EAT EG ESP EWT EXIST EXH EXP F FCO FD FDC FLA FPM FT G GA GAL GALV GPM GWB HP HVAC HW HWC HWR HWS ID IE IN KW LAT LWT MAX MBH MCA MFG MIN MTG NC NIC NFPA NG NO NTS OA OAT OC OBD ORD oS&Y PH POC PSI RA RL RD REF REQD RG RPM RPBP RS SA SD SHT SP SPD SPEC TDH TPD TSP TYP V VD VTR W WB W/ WC wc0 WG WH WHA AIR CONDITIONING AIR CONDITIONING UNIT ACCESS DOOR ABOVE FINISHED FLOOR APPROXIMATE ARCHITECT AMERICAN SOCIETY OF HEATING, REFRIGERATION AND AIR CONDITIONING ENGINEERS BACKDRAFT DAMPER BELOW FINISHED FLOOR BRITISH THERMAL UNITS PER HOUR CEILING DIFFUSER CUBIC FEET PER MINUTE CIRCULATING CLEAN OUT CONDENSATE CONTINUATION COORDINATE CLEAN OUT TO GRADE COLD WATER DEGREE DIAMETER DIMENSION DOWN DRAWING EXISTING, EACH, EXHAUST AIR ELEVATION ENTERING AIR TEMPERATURE EXHAUST GRILLE EXTERNAL STATIC PRESSURE ENTERING WATER TEMPERATURE EXISTING EXHAUST EXPANSION FAHRENHEIT FLOOR CLEANOUT FIRE DAMPER, FLOOR DRAIN FIRE DEPARTMENT CONNECTION FULL LOAD AMPS FEET PER MINUTE FOOT, FEET NATURAL GAS GAUGE GALLONS GALVANIZED GALLONS PER MINUTE GYPSUM WALL BOARD HORSEPOWER HEATING, VENTILATION AND AIR CONDITIONING HOT WATER HOT WATER CIRCULATION HOT WATER RETURN HOT WATER SUPPLY INDIRECT DRAIN, INSIDE DIAMETER INVERT ELEVATION INCH KILOWATT (1000 WATTS) LEAVING AIR TEMPERATURE LEAVING WATER TEMPERATURE MAXIMUM 1000 BTU PER HOUR MINIMUM CIRCUIT AMPS MANUFACTURER MINIMUM MOUNTING NORMALLY CLOSED NOT IN CONTRACT NATIONAL FIRE PROTECTION ASSOCIATION NATURAL GAS NORMALLY OPEN NOT TO SCALE OUTSIDE AIR OUTSIDE AIR TEMPERATURE ON CENTER OPPOSED BLADE DAMPER OVERFLOW ROOF DRAIN OUTSIDE STEM AND YOLK PHASE POINT OF CONNECTION POUNDS PER SQUARE INCH RETURN AIR RAIN LEADER, REFRIGERANT LIQUID ROOF DRAIN REFERENCE REQUIRED RETURN GRILLE REVOLUTIONS PER MINUTE REDUCED PRESSURE BACKFLOW PREVENTER REFRIGERANT STEAM SUPPLY AIR STORM DRAIN SHEET STATIC PRESSURE STATIC PRESSURE DROP SPECIFICATIONS TOTAL DYNAMIC HEAD TOTAL PRESSURE DROP TOTAL STATIC PRESSURE TYPICAL VOLT, VENT VOLUME DAMPER VENT THRU ROOF WASTE WET BULB TEMPERATURE WITH WATER CLOSET WALL CLEAN OUT WATER GAUGE WALL HYDRANT WATER HAMMER ARRESTER NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED 6/4/2018 6:07:40 PM SYMBOL OR C XxY AUR DESCRIPTION DETAIL OR SECTION CALLOUT SHEET WHERE SECTION OR DETAIL SHOWN DIRECTION OF CUTTING PLANE SECTION CUT LINE DIRECTION OF FLOW EQUIPMENT ITEM XX LINE, ARCHITECTURAL BACKGROUND LIGHT LINE, EXISTING HEAVY LINE, NEW WORK ROUND DUCT DIAMETER X PLAN OR HORIZONTAL DIMENSION Y ELEVATION OR VERTICAL DIMENSION ' �-- $G--X XXX —rDN� + UP I + { -o ><1 -01— 4*- 0 T OR EQUIP ID# •1 RS RL C EXISTING WORK TO BE REMOVED BREAK IN PIPE OR DUCTWORK FLAG NOTE REVISION NOTE AREA CLOUDED CONTAINS CHANGES TO DRAWINGS SUBSEQUENT TO PREVIOUS ISSUE DIFFUSER, REGISTER OR GRILLE CALL OUT CFM AMOUNT DN DUCT OFFSET DOWN IN FLOW DIRECTION UP DUCT OFFSET UP IN FLOW DIRECTION DUCT WITHOUT INSULATION INSULATED DUCT UNDERGROUND OR ATTIC DUCT W/ INSULATION ALTERNATE DUCT DUCT FLEX CONNECTION RA/EA RG SA SA RA/EA SD VOLUME DAMPER RETURN AIR OR EXHAUST AIR DUCT RETURN AIR GRILLE SUPPLY AIR OUTLET, SIDEWALL SUPPLY AIR DUCT RETURN AIR OR EXHAUST AIR DUCT SUPPLY GRILLE OR DIFFUSER OPEN AREA INDICATED ACTIVE ELEMENTS (4 WAY IF HATCH IS NOT SHOWN) LINEAR DIFFUSER EA EXHAUST AIR DUCT, EXHAUST AIR GRILLE TRANSITION — RECTANGULAR TO ROUND RS RL C RECTANGULAR ELBOW WITH TURNING VANES SWITCH THERMOSTAT EQUIPMENT LOCATION PIPE/DUCT ELBOW DOWN PIPE/DUCT ELBOW UP BALL VALVE APPLIANCE REGULATOR TWO WAY VALVE DIRT LEG CLEARANCE REQUIREMENT REFRIGERANT SUCTION PIPING REFRIGERANT LIQUID PIPING CONDENSATE PIPING ROOM CALL OUT MO.1 ABBREVS., LEGEND, DRAWING INDEX, GENERAL NOTES, HP LOAD CALCULATION, SCHEDULES AND MECHANICAL DETAILS MD2.1 ELEVATOR LANDING AND MACHINE ROOM MECHANICAL DEMOLITION FLOOR PLANS MD2.2 ELEVATOR LANDING AND ROOF MECHANICAL DEMOLITION PLANS M2.1 ELEVATOR LANDING AND MACHINE ROOM MECHANICAL FLOOR PLANS EVD2.1 ELEVATOR LANDING AND MACHINE ROOM ELEVATOR DEMOLITION FLOOR PLANS EVD2.2 ELEVATOR LANDING AND ROOF ELEVATOR DEMOLITION PLANS EV2.1 ELEVATOR LANDING AND MACHINE ROOM ELEVATOR FLOOR PLANS EV2.2 ELEVATOR LANDING AND ROOF ELEVATOR PLANS EV2.3 ELEVATOR DIAGRAMS GENERAL NOTES THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION. 2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE ENGINEER. COORDINATE THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION. 3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM PLANS. 4. INSULATION SHALL MEET WASHINGTON STATE ENERGY CODE (WSEC). 5. PENETRATIONS THROUGHOUT 2—HOUR FIRE RATED WALLS, PARTITIONS, CEILINGS AND ROOF ASSEMBLIES SHALL RECEIVE 2—HOUR FIRE STOP RATED UL APPROVED SEALANT FROM INSIDE AND WEATHER RESISTANT SEALANT FROM OUTSIDE. 6. PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR. 7. PROVIDE ALL REQUIRED EQUIPMENT GUARDS AND STRUCTURAL SUPPORT AS RECOMMENDED BY EQUIPMENT MANUFACTURERS TO SUPPORT EQUIPMENT AND TO ASSURE SYSTEM PERFORMANCE AND SAFE OPERATION. COORDINATE PRIOR TO INSTALLATION. PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS. 8. PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. BUILDING AND STRUCTURE IS DESIGNED TO SUPPORT EQUIPMENT, BUT NOT DETAILED TO ACCOMMODATE EACH AVAILABLE EQUIPMENT CONFIGURATION OR MANUFACTURER. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS, HANGERS, ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT. 9. PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED. HP-1 LOAD CALCULATION ELEVATOR MOTOR = 25HP HOURLY DUTY CYCLE = 12% WATTS PER MOTOR HP = 746 WATTS SENSIBLE/TOTAL COOLING RATIO = 69% SENSIBLE HEAT GAIN = 25HP x 746W/HP x 12% x 3.413(BTU/H)/W = 7.638 BTU/H SENSIBLE GROSS TOTAL COOLING LOAD = 7,638(BTU/H)/69% = 11.070 BTU/H TOTAL HP-1 TOTAL COOLING PROVIDED = 18.000 BTU/H TOTAL AIR DISCHARGE FAN RS & RL TO INDOOR UNIT, HP-1 SERVICE PANEL RS & RL, MAKE FLEXIBLE BY SECURING WITH PIPE CLAMP OVER INSULATION TRANSPORTING HANDLE PROVIDE PVC VANDAL RESISTANT COVER FOR ABOVE GROUND RS & RL NEOPRENE VIBRATION ISOLATORS HEAT PUMP OUTDOOR UNIT, HP-1 PVC SLEEPERS GRADE HEAT PUMP UNIT SCHEDULE - EXT. COOLING HEATING ELECTRICAL MARK CFM STATIC PRES. NOMINAL BTUH NOMINAL BTUH SEER WEIGHT, LBS. DESCRIPTION MCA MOCP VOLT PHASE HP-1 700 0.0" 18,000 19,000 15.3 29 1 ' 20 208/ 1 MITSUBISHI PKA—A18HA4 OR ACCEPTED EQUAL, INDOOR INDOOR 230 WALL —MOUNTED INDOOR UNIT, WITH REFRIGERANT LINE KIT, CONDENSATE PUMP AND WALL — MOUNTED THERMOSTAT. OUTDOOR OUTDOOR 15.3 91 13 208/ 1 PUZ—A18NHA4 OR ACCEPTED EQUAL. 230 PROVIDE 3-1/4" X 3-1/4" PVC SLEEPERS, MITSUBISHI DSD-400N OR ACCEPTED EQUAL. NOTES: 1. ECONOMIZER NOT REQUIRED PER WSEC PART C403.3, EXCEPTION 3. 1-1 I I-1 I I-1 I I-III-III-III-III=1 I i-I I I- �' ICI I I. ' .-1 I I—! I I=1 11=1 I I —I 11=1 I I —III —I 11- -1 I I; 7: 111111=1 I I=I I I=1 11-1 I I rl 11=1 I IEI I I =1 I I-1 I I-1 11-1 I I-1 I I-1 11-1 11=1 I i- —ill.;,lll_lllli�llll��lll���lll„_,III ;,ill —ill -III,,; III„ "Ill�lll��lliliiilili� "' HP-1 OUTDOOR UNIT INSTALLATION DETAIL SCALE: NTS REFRIGERANT LIQUID AND SUCTION LINES TO OUTDOOR UNIT HP-1 INDOOR UNIT, WALL MOUNTED FRONT HP-1 INDOOR UNIT SCALE: NTS PIPE REVISIONS No changss sl1^'I h'? m^de to the scope of work r,-or approval of i t , r, ,:;ng Divi ,� son ! ,r; ;,1 r 4 .,:.i+ o a rr^'.v plan submittal G IJ 111� a.eEr7 � '��!"tir. � �n .y in.. a EIc,..: on Wan review fees. BACK PUMP CONDENSATE DRAIN LINE, TERMINATE 6" ABOVE EXTERIOR GRADE NSTALLATION DETAIL FIRE RATED SEALANT (MIN. 3 HR RATED) ESCUTCHEON, 24 GA GI WHERE EXPOSED WITHIN FINISHED ENVIRONMENT FILE C.PY Permit No. M 1$- a I I3 Plan review e' proval 13 sub act to errors a :d c:.!:eions. Approval of const uc:,on documents docs n the violation cf any cc:opted coda or Ord:f :cc. f::. —: t of approved Field Copy and condions is PIPE THROUGH WALL DETAIL SCALE: NTS By:---.� Date: i l City of Tukwila iNG DIViCION A / 3 43) l ` O14y / I 6-7L-ovr REVIEWED FOR CODE COMPLIANCE APPROVED SEP 11 2U1 City of -Tukwila BUILDING DIVISION ❑ P" c - nic d ..rIi i 'vrnbinQ 'Cos Pipi 1cfTc! �'jfl !V!::-. ION 1050 N.38th St. Seattle, WA 98103 PH: 206.675.9151 www,shksarchitects.com THE GREENBUSCH. GROUP, INC. King County Housing Authority KCHA RIVERTON TERRACE II ELEVATORS PERMIT SET 14410 41 ST AVE S TUKWILA, WA 98169 Drawn by: Checked: Date: Scale: Revisions: No. Date DR RF 8/272018 1/4" = 1'-0" Remarks ABBREVS., LEGEND, DRAWING INDEX, GENERAL NOTES, HP LOAD CALCULATION, SCHEDULES AND MECHANICAL DETAILS M0.1 SHKSARCHITECTS 4/2018 6:07:40 PM CO SHEET NOTES: FLAG NOTES: 1. THE DEMOLITION DRAWINGS ARE DIAGRAMMATIC IN NATURE. CONTRACTOR IS RESPONSIBLE FOR COMPLETE REMOVAL OF INDICATED SYSTEMS & ASSOCIATED APPURTENANCES UNIT REMOVE EXISTING LOUVER, INFILL, PATCH, AND PAINT WALL TO MATCH SURROUNDING WALL. CUT AND CAP EXTRANEOUS PIPE THAT PROTRUDES INTO ELEVATOR PIT AND PATCH WALL. REMOVE UNRELATED CONDUIT AND JUNCTION BOX IN THE PIT AND PATCH WALL. REMOVE EXISTING SPRINKLER HEAD AND PIPING, CAP PIPING AS SHOWN AT THE MACHINE ROOM AND REROUTE SPRINKLER LINE TO PIT, AS SHOWN ON M2.1. (E) MAILBOXES VESTIBULE E) LOUVER LOBBY UNIT FIRST FLOOR PLAN 1/4" = 1'-0° (E) STAIRS MAINTENANCE ELEC LAUNDRY REMOVE EXHAUST FAN, CAP DUCT, PATCH AND INFILL. 3 MACHINE (E) LOUVER (E) EXTRANEOUS PIPE LOBBY (E) JUNCTION BOX RR W CD cc cn KITCHEN BASEMENT 1 /4" = 11-0" COMMUNITY ROOM (E) SPRINKLER LINE N (E) LOUVER RR OFFICE (E) STAIRS REVIEWED FOR - CODE COMPLIANCE APPROVED SEA' 1 .NIB City of Tukwila BUILDING DIVISION 1050 N.38th St. Seattle, WA 98103 PH: 206.675.9151 www.shksarchitects.com THE GREENBUSCH GROUP, INC. King County Housing Authority KCHA RIVERTON TERRACE II ELEVATORS PERMIT SET 14410 41ST AVE S TUKWILA, WA 98169 Drawn by: DR Checked: RF Date: 8/272018 Scale: 1/4" = 1'-0° Revisions: No. Date Remarks ELEVATOR LANDING AND MACHINE ROOM MECHANICAL DEMOLITION FLOOR PLANS MD2.1 0 4 8 16 SHKSARCHITECTS SHEET NOTES: FLAG NOTES: 1. THE DEMOLITION DRAWINGS ARE DIAGRAMMATIC IN NATURE. CONTRACTOR IS RESPONSIBLE FOR COMPLETE REMOVAL OF INDICATED SYSTEMS & ASSOCIATED APPURTENANCES 6/4/2018 6:07:40 PM REMOVE EXISTING LOUVER, INFILL, PATCH, AND PAINT WALL TO MATCH SURROUNDING WALL. REMOVE EXISTING VENT, CAP ROOF CURB. (E) LOUVER UNIT LOBBY NO MECHANICAL DEMOLITION WORK IN THIS LEVEL UNIT SECOND FLOOR PLAN 1/4" = 11-0" (E) STAIRS REVIEVVtD CODE COMPLIANCE APPROVED SEP 1 2018 City of Tukwila BUILDING DIVISION 1050 N.38th St. Seattle, WA 98103 PH: 206.675.9151 www.shksarchitects.com T H E GREENBUSCH GROUP, INC. King County Housing Authority KCHA RIVERTON TERRACE II ELEVATORS PERMIT SET 14410 41ST AVE S TUKWILA, WA 98169 Drawn by: DR Checked: RF Date: 8/272018 Scale: 1/4" = 11-0" Revisions: No. Date Remarks ELEVATOR LANDING AND ROOF MECHANICAL DEMOLITION PLANS MD2.2 6 SHKSARCHITECTS 6/4/2018 6:07:40 PM DRAWING NOTES: 1. PROVIDE CUTTING AND PATCHING AS SPECIFIED AND AS REQUIRED TO INSTALL NEW PIPING AND EQUIPMENT. UNIT FLAG NOTES: CUT AND PATCH WALL AS REQUIRED TO INSTALL HP-1 REFRIGERANT PIPING. COORDINATE LOCATION OF HP-1. INDOOR UNIT WITH THE ELEVATOR CONTRACTOR AND KCHA CONSTRUCTION MANAGER PRIOR TO WALL CUTTING. INSTALL HP-1 INDOOR UNIT IN ELEVATOR MACHINE ROOM. ROUTE RL/RS ABOVE THE CEILING TILES TO THE HP-1 OUTDOOR UNIT MOUNTED OUTDOORS. PROVIDE PVC CONTAINMENT FOR ALL EXPOSED REFRIGERANT AND CONDENSATE PIPING. PAINT TO MATCH EXISTING WALL COLOR. PUMP CONDENSATE TO EXTERIOR. TERMINATE 6" ABOVE GRADE. COORDINATE FINAL HP-1 OUTDOOR UNIT LOCATION WITH KCHA CONSTRUCTION MANAGER. (E) MAILBOXES LOBBY NO MECHANICAL WORK THIS LEVEL VESTIBULE UNIT FIRST FLOOR PLAN 1/4" = 11-0" (E) STAIRS LOCATE HP-1 OUTDOOR UNIT ON SLEEPERS. REFER TO EQUIPMENT SCHEDULE AND ARCHITECTURAL DOCUMENTS.. MOUNT SIDE -WALL SPRINKLER NOT MORE THAN 2' ABOVE PIT FLOOR. COORDINATE SPRINKLER LOCATION AND PIPE ROUTING WITH ELEVATOR CONTRACTOR. MAINTENANCE ELEC SEE LAUNDRY a MACHINE C P.O.0 LOBBY RR w CC KITCHEN ROUTE REFRIGERANT INSIDE WALL, EXIT THE WALL WI TH I N 12" OF THE OUTDOOR UNIT BASEMENT HP-1 8 SEE COMMUNITY ROOM RR OFFICE (E) STAIRS REVIE yj.? + F CODE COMPLIANCE APPROV93 SEA' 11. 2018 City of Tukwila BUILDING DIVISION 0113 1050 N.38th St. Seattle, WA 98103 PH: 206.675.9151 www.shksarchitects.com THE GREENBUSCH GROUP, INC. King County Housing Authority KCHA RIVERTON TERRACE II ELEVATORS PERMIT SET 14410 41ST AVE S TUKWILA, WA 98169 Drawn by: Checked: Date: Scale: Revisions: No. Date DR RF 8/272018 1/4" = 1'-0° Remarks ELEVATOR LANDING AND MACHINE ROOM MECHANICAL FLOOR PLANS M2.1 SHKSARCHITECTS 6/4/2018 6:07:40 PM GENERAL DEMOLITION NOTES: 1. THE DEMOLITION SHOWN DOES NOT ATTEMPT TO COVER ALL ITEMS WHICH MUST BE REMOVED OR REPLACED AS PART OF THE ELEVATOR MODERNIZATION, CONTRACTOR IS NOT RELIEVED FROM PROVIDING ALL DEMOLITION SERVICES REQUIRED TO COMPLETE THE SCOPE SPECIFIED IN THE CONTRACT DOCUMENTS. UNIT FLAG NOTES: REMOVE EXISTING SHUTOFF VALVE, RUPTURE VALVE AND ASSOCIATED LENGTH OF PIPE TO ALLOW INSTALLATION OF NEW SHUT OFF VALVE AND RUPTURE VALVE. REMOVE EXISTING POWER UNIT & ASSOCIATED CONTROLLER. REMOVE EXISTING HYDRAULIC LINES ALONG WITH THE EXISTING SHUTOFF VALVE AND MUFFLER, REMOVE EXISTING INGROUND JACK ASSEMBLY COMPLETE. DEMOLISH SURROUNDING SLAB AS REQUIRED FOR REMOVAL. REMOVE EXISTING HALL LANTERNS AND FIXTURES. LOBBY VESTIBULE (E) MAILBOXES UNIT FIRST FLOOR PLAN 1/4" = 11-0" (E) STAIRS MAINTENANCE ELEC LAUNDRY CONTROLLER E) JACK LOBBY RR w CC KITCHEN BASEMENT COMMUNITY ROOM RR OFFICE (E) STAIRS CODE COMA-, AINCE APPROVED SEP 1, 2018 City of Tukwila BUILDING DIVISION 1050 N.38th St. Seattle, WA 98103 PH: 206.675.9151 www.shksarchitects.com THE GREENBUSCH GROUP, INC. King County Housing Authority KCHA RIVERTON TERRACE 11 ELEVATORS PERMIT SET 14410 41ST AVE S TUKWILA, WA 98169 Drawn by: Checked: Date: Scale: Revisions: No. Date DR RF 8/272018 1/4" = 11-0" Remarks ELEVATOR LANDING AND MACHINE ROOM ELEVATOR DEMOLITION FLOOR PLANS EVD2 1 0 4 8 16 SHKSARCHITECTS SHEET NOTES: FLAG NOTES: . THE DEMOLITION DRAWINGS ARE DIAGRAMMATIC IN NATURE. CONTRACTOR IS RESPONSIBLE FOR COMPLETE REMOVAL OF INDICATED SYSTEMS & ASSOCIATED APPURTENANCES 6/4/2018 6:07:40 PM REMOVE EXISTING HALL LANTERNS AND FIXTURES. NO ELL, ATOR DEMOLITION WORK U. THIS LEVEL UNIT IP LOBBY (E) STAIRS UNIT SECOND FLOOR PLAN 1/4" = 11-0" 111 , • „ . . . -E.ViE-VVEI) FOP CODE COMPLANL,E APPROVED SEP 112018 City of Tukwila BUILDING DIVISION 3 AU'..3 3 1050 N. 38th St. Seattle, WA 98103 PH: 206.675.9151 www.shksarchitects.com THE GREENBUSCH G RO U P, INC King County Housing Authority KCHA RIVERTON TERRACE II ELEVATORS PERMIT SET 14410 41ST AVE S TUKWILA, WA 98169 Drawn by: DR Checked: RF Date: 8/272018 Scale: 1/4" = 11-0" Revisions: No. Date Remarks ELEVATOR LANDING AND ROOF ELEVATOR DEMOLITION PLANS ED EVD2 16 SHKSARCHITECTS /2018 6:07:40 PM SHEET NOTES: FLAG NOTES: 1. PROVIDE CUTTING AND PATCHING AS SPECIFIED AND AS REQUIRED TO INSTALL NEW PIPING AND EQUIPMENT. UNIT PROVIDE NEW SURFACE MOUNTED HALL CALL BUTTONS. PROVIDE NEW SURFACE MOUNTED HALL LANTERNS. PROVIDE NEW SUBMERSIBLE POWER UNIT AND SOLID STATE MICROPROCESSOR BASED CONTROLS. HALL BUTTON FIXTURES AT EACH FLOOR SHALL BE PROVIDED WITH INTEGRAL POSITION INDICATORS. NEW SHUTOFF VALVE MOUNTED IN VERTICAL. PROVIDE NEW SHUTOFF VALVE AND RUPTURE VALVE. CUT AND PATCH WALL AS REQUIRED TO INSTALL NEW HYDRAULIC LINE. PROVIDE NEW DOUBLE BOTTOM JACK ASSEMBLY. REPLACE SURROUNDING SLAB AS NECESSARY. LOBBY VESTIBULE (E) MAILBOXES UNIT FIRST FLOOR PLAN (E) STAIRS 1/4" = MAINTENANCE ELEC HP-1 (BY MECHANICAL) LAUNDRY LIGHT SWITCH, DISCONNECT (BY ELECTRICAL) LOCATE WITHIN 24 INCHES OF THE CONTROL ROOM DOOR STRIKE SIDE (NIEC) ONTROLLE m, cF PROVIDE PIT ACCESS LADDER AND LIGHT SWITCH (NIEC). LOBBY RR CI) KITCHEN COMMUNITY ROOM - SEE SEE RR OFFICE (E) STAIRS REVu R CODE COMPLIANL,E APPROVED SEP 1] 2G18 City of Tukwila BUILDING DIVISION 1050 N.38th St. Seattle, VVA 98103 PH: 206.675.9151 www.shksarchitects.com THE GREENBUSCH GROUP, INC. King County Housing Authority KCHA RIVERTON TERRACE II ELEVATORS PERMIT SET 14410 41ST AVE S TUKWILA, WA 98169 Drawn by: DR Checked: RF Date: 8/272018 Scale: 1/4" = 11-0" Revisions: No, Date Remarks ELEVATOR LANDING AND MACHINE ROOM ELEVATOR FLOOR PLANS \Pr 1 SHKSARCHITECTS SHEET NOTES: FLAG NOTES: 1. PROVIDE CUTTING AND PATCHING AS SPECIFIED AND AS REQUIRED TO INSTALL NEW PIPING AND EQUIPMENT. 6/4/2018 6:07:40 PM PROVIDE NEW SURFACE MOUNTED HALL CALL BUTTONS. PROVIDE NEW SURFACE MOUNTED HALL LANTERNS. HALL BUTTON FIXTURES AT EACH FLOOR SHALL BE PROVIDED WITH INTEGRAL POSITION INDICATORS. _J NO ELEVATOR WORK IN THIS LEVEL UNIT LOBBY >>> UNIT SECOND FLOOR PLAN 1/4" = 1'-0" (E) STAIRS co APPROVLD 3EP 2018 City of Tukwila U WING DIViSION 1050 N. 38th St. Seattle, WA 98103 PH. 206.675.9151 www.shksarchitects.com THE GREENBUSCH GROUP, INC. King County Housing Authority KCHA RIVERTON TERRACE II ELEVATORS PERMIT SET 14410 41ST AVE S TUKWILA, WA 98169 Drawn by: DR Checked: RF Date: 8/272018 Scale: 1/4" = 11-0" Revisions: Na. Date Remarks ELEVATOR LANDING AND ROOF ELEVATOR PLANS CD EV2.2 0 4 8 16 34 SHKSARCHITECTS SHEET NOTES: 1. PROVIDE CUTTING AND PATCHING AS SPECIFIED AND AS REQUIRED TO INSTALL NEW PIPING AND EQUIPMENT. FLAG NOTES: PROVIDE NEW POSITION INDICATORS INTEGRATED WITHIN HALL FIXTURES AT EACH LANDING EXISTING JACK TO BE REMOVED AND REPLACED WITH NEW DOUBLE BOTTOM JACK. PROVIDE SHUT—OFF VALVES AND SEISMIC SAFETY VALVE. SPRING BUFFERS AND CHANNEL, PROVIDE NEW GUIDE RAILS EXISTING TO REMAIN. PROVIDE RAIL BACKING OR FISH PLATES AS REQUIRED TO MEET THE ELEVATOR SAFETY CODE. FIELD VERIFY AND PROVIDE QUANTITY REQUIRED. ELEVATOR CAR FRAME AND PLATFORM EXISTING TO REMAIN. FINISHES AS SPECIFIED . PROVIDE NEW HANDRAILS. PROVIDE NEW HALL LANTERNS PROVIDE CAR EXHAUST FAN. PROVIDE CAR OPERATING PANEL WITH TELEPHONE, INTERCOM EMERGENCY LIGHT AND LED POSITION, DIRECTION INDICATORS, AND KEYSWITCH OVERRIDE. PROVIDE CAR LED LIGHTING. PROVIDE CAR TOP OPERATING STATION. PROVIDE NEW TRAVELING CABLES. PROVIDE TERMINAL LIMIT SWITCHES. PROVIDE ADA JAMB PLATES. PROVIDE HALL BUTTONS TO MEET ACCESSIBILITY REQUIREMENTS. PROVIDE NEW TOE GUARD. FASCIA PLATES EXISTING TO REMAIN. LANDING SILLS ARE EXISTING TO REMAIN. PROVIDE NEW CLOSED LOOP DOOR OPERATOR. PROVIDE DUST COVER PROVIDE DOOR EDGE PROTECTION DEVICE. PROVIDE FIRE SIGNAGE AT EACH LANDING PROHIBITING USE OF ELEVATOR,DURING FIRE. SIGNAGE MAY BE INCORPORTATED INTO HALL STATIONS. PROVIDE NEW ROLLER GUIDES. PROVIDE CAR TOP HATCH WITH ALARM. PROVIDE CAR TOP HAND RAILS AS REQUIRED BY WAC 296-96-23117 (VERIFY) PATCH ALL EXISTING AND CREATED HOLES IN THE HOISTWAY. PROVIDE NEW INTERCOM AT FIRST FLOOR LOBBY. PROVIDE NEW FIRE DEPARTMENT KEY BOX AT FIRST FLOOR LOBBY. PROVIDE NEW SLAB AS REQUIRED DURING JACK REPLACEMENT. HOISTWAYS ENTRANCES REPAINTED (BY OTHERS). PROVIDE NEW CODE COMPLIANT PIT LADDER. PROVIDE HOISTWAY ACCESS KEYSWITCHES AT TERMINAL LANDINGS. 6/4/2018 6:07:40 PM 15 ROOF TYP LEVEL 21 22 19 18 LEVEL 2 0 LLI li LEVEL Z Z 0 20 DIAGRAMMATIC HOISTWAY SECTION TYP 27 TYP 14 TO ELEVATOR MACHINE ROOM 31 1 32 TYPICAL ELEVATOR LOBBY SCALE: NTS (TYPICAL) CAR FRONT ELEVATION CAR FLOOR PLAN 23 CAR SIDE ELEVATION TYP TYP 6 TYP NOTE: REFER ARCHITECTURAL FOR ADDITIONAL LOCATION INFORMATION CAR REAR ELEVATION TYP 0 0 \4tk \'P 0 0 < O CAR SIDE ELEVATION City of Tukwi BUILDING DIVISION 1050 N.38th St. Seattle, WA 98103 PH: 206.675.9151 www.shksarchitects.com T H E GREENBUSCH GROUP, INC. King County Housing Authority KCHA RIVERTON TERRACE II ELEVATORS PERMIT SET 14410 41ST AVE S TUKWILA, WA 98169 Drawn by: Checked: Date: Scale: Revisions: No. Date DR RF 8/272018 1/4" = 1'-0" ELEVATOR DIAGRAMS Remarks EV213