Loading...
HomeMy WebLinkAboutPermit M18-0117 - SEATTLE CHILDRENS - AIR HANDLER UNIT, DIFFUSERS AND DUCTWORKSEATTLE CHILDREN'S 3355 S 120 PL 120 M18-0117 Parcel No: Address: r1 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 1023049082 Permit Number: 3355 S 120TH PL 120 Project Name: SEATTLE CHILDRENS Issue Date: Permit Expires On: M18-0117 10/3/2018 4/1/2019 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: SABEY CORPORATION 12201 TUKWILA INTL BLVD 4TH FL, SEATTLE, WA, 98168 KAYLENE NELSON 1221 SECOND AVE N , KENT, WA, 98032 HERMANSON COMPANY LLP (GENERAL) 1221 2ND AVE N , KENT, WA, 98032- 2945 H E R MACL005 BJ Phone: (253) 359-7147 Phone: (206) 575-9700 Expiration Date: 8/25/2020 DESCRIPTION OF WORK: 1 VAV, RELOCATE ^' 20 DEFFUSERS. MODIFY DUCT AS NEEDED Valuation of Work: $32,000.00 Type of Work: REPLACEMENT Fuel type: ELECT Fees Collected: $749.23 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: 125 Sewer District: VALLEY VIEW Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Date: 10 \ 15 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature. Print Name: 19 .NI_ `ScAf Date: 10 1.)k This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 4: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 8: ***MECHANICAL PERMIT CONDITIONS*** 9: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 10: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL CITY OF TUKJ( 'A Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 hap: www.TukwitaWA.go\- Mechanical Permit No. IlkA (6'olio Project No. Date Application Accepted: Date Application Expires: 111 4 (For office u e only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION King Co Assessor's Tax No.: 1023049082 Site Address: 3355 S 120TH Place Suite Number: Floor: 1 Tenant Name: Seattle Childrens PROPERTY OWNER Name: Sabey Address: 12201 Tukwila International BLVD City: Tukwila State: WA Zip: 98168 CONTACT PERSON — person receiving all project communication Name: Kaylene Nelson Address: 1221 2nd Avenue N City: Kent State: WA Zip: 98032 Phone: (253) 359-7147 Fax: Email: Kaylene.nelson@hermanson.com New Tenant: El Yes ❑ .. No MECHANICAL CONTRACTOR INFORMATION Company Name: Hermanson Company Address: 1221 2nd Avenue N City: Kent State: WA Zip: 98032 Phone: (253) 359-7147 Fax: Contr Reg No.: HERMACLOO5BJ Exp Date: 08/25/2018 Tukwila Business License No.: BUS -0994464 Valuation of project (contractor's bid price): $ 32,000 Describe the scope of work in detail: 1 VAV, Relocate —20 diffusers. Modify duct as needed and i Use: Fuel Type: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement Electric Gas ❑ Other: H: Applications Forms -Applications On Linc 201 1 Applications Mechanical Permit Application Revised S-9-11.docx Revised: August 2011 bh Page 1 of 2 / / Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu 1 Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm 1 Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser 20 Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 ' I R AUTH RIZE AGENT: Signature: Date: 09/11/2018 Print Name: aylene Nelson Day Telephone: (253) 359-7147 Mailing Address: 1221 2nd Avenue N H: Applications Forms -Applications On Line 2011 Applications Mechanical Permit Application Revised 8-9-1 1.docx Revised: August 22011 bh Kent WA 98032 City State Zip Page 2 of 2 r� DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $109.80 M18-0117 Address: 3355 5 120TH PL 120 Apn: 1023049082 $109.80 Credit Card Fee $3.20 Credit Card Fee R000.369.908.00.00 0.00 $3.20 MECHANICAL $102.50 PERMIT FEE R000.322.100.00.00 0.00 $102.50 TECHNOLOGY FEE $4.10 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R15540 R000.322.900.04.00 0.00 $4.10 $109.80 Date Paid: Wednesday, October 03, 2018 Paid By: KAYLENE NELSON Pay Method: CREDIT CARD 543927 Printed: Wednesday, October 03, 2018 1:10 PM 1 of 1 1 SYSTEMS Page 1 of 2 CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA 0017340000802374464500 Date: 10/03/2018 01:10:19 PM CREDIT CARD SALE VISA CARD NUMBER: **********0057 K TRAN AMOUNT: $109.80 APPROVAL CD: 543927 RECORD #: 000 CLERK ID: Bill X {CARDHOLDER'S SIGNATURE} I AGREE TO PAY THE ABOVE TOTAL AMOUNT ACCORDING TO THE CARD ISSUER AGREEMENT (MERCHANT AGREEMENT IF CREDIT VOUCHER) Thank you! Merchant Copy https://classic.convergepay.com/VirtualMerchant/transaction. do?dispatchMethod=printTra... 10/3/2018 Page 1 of 2 CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA 0017340000802374464500 Date: 09/17/2018 12:29:25 PM CREDIT CARD SALE VISA CARD NUMBER: **********0057 K TRAN AMOUNT: $532.83 APPROVAL CD: 256941 RECORD #: 000 CLERK ID: Rachelle X {CARDHOLDER'S SIGNATURE} I AGREE TO PAY THE ABOVE TOTAL AMOUNT ACCORDING TO THE CARD ISSUER AGREEMENT (MERCHANT AGREEMENT IF CREDIT VOUCHER) Thank you! Merchant Copy http s ://classic.convergepay. com/V irtualMerchant/transaction. do?dispatchMethod=printTra... 9/17/2018 Page 2 of 2 CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA Date: 09/17/2018 12:29:25 PM CREDIT CARD SALE VISA CARD NUMBER: **********0057 K TRAN AMOUNT: $532.83 APPROVAL CD: 256941 RECORD #: 000 CLERK ID: Rachelle Thank you! Customer Copy https://classic.convergepay.comNirtualMerchant/transaction.do?dispatchMethod=printTra... 9/17/2018 INSPECTION RECORD Retain a copy with permit (18`0/1 / JS INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: - S CRI Type of I spection: F,a Address: IS 3-355_S• 12o 00 Date Calle : Special Instructions: Date Wanted:L(r l 0'`I a.m: Hermanson Building Today, Defining Tomorrow Hermanson Company LLP 1221 2nd Avenue North Kent, WA 98032 tel 206-575-9700 fax 206-575-9800 Project: 3355 S 120th Place Tukwila, WA Date: 09/04/2018 r September 7, 2018 2018.09.07 08:11:11-07'00' Document approved, mechanical design pages REVIEWED FOR CODE COMPLIANCE APPROVED SEP 2 7 2018 City of Tukwila BUILDING DIVISION REr,EM .D CITY OF TUK ilLA SEP 17 2018 PERMIT CENTER HVAC SYSTEM COOLING/HEATING CALCS CARRIER HAP VERSION: 5.11 PERMIT SUBMITTAL PACKAGE N11�� b111 Mechanical Construction, Engineering and Service www.hermanson.com Hermanson Building Today, Defining Tomorrow Hermanson Company LLP 1221 2nd Avenue North Kent, WA 98032 tel 206-575-9700 fax 206-575-9800 Project: 3355 S 120th Place Tukwila, WA Date: 09/04/2018 Hermanson Building Today, Defining Tomorrow HVAC SYSTEM COOLING/HEATING CALCS CARRIER HAP VERSION: 5.11 ENVELOPE INPUTS Mechanical Construction, Engineering and Service www.hermanson.com TUK_SABEY_SEA CHILDRENS 1ST FL_v5_11 HERMANSON COMPANY LLP Wall Constructions 09/06/2018 03:44PM Existing Wall Wall Details Outside Surface Color Absorptivity Overall U -Value Wall Lavers Details (Inside to Outside Medium 0.675 0.114 BTU/(hr•ft2•°F) Layers Thickness in Density Ib/ft3 Specific Ht. BTU / (Ib•°F) R -Value (hr•ft2•°F)/BTU Weight Ib/ft2 Inside surface resistance 0.000 0.0 0.00 0.68500 0.0 Gypsum board 0.625 50.0 0.26 0.56000 2.6 R-11 batt insulation 3.500 0.5 0.20 6.50000 0.1 8 -in HW concrete 8.000 140.0 0.20 0.66667 93.3 Outside surface resistance 0.000 0.0 0.00 0.33300 0.0 Totals 12.125 - 8.74467 96.1 Hourly Analysis Program v5.11 Page 1 of 1 Hermanson J Building Today, Defining Tomorrow Hermanson Company LLP 1221 2nd Avenue North Kent, WA 98032 tel 206-575-9700 fax 206-575-9800 Project: 3355 S 120th Place Tukwila, WA Date: 09/04/2018 Hermanson Building Today, Defining Tomorrow HVAC SYSTEM COOLING/HEATING CALCS CARRIER HAP VERSION: 5.11 SPACE INPUTS Mechanical Construction, Engineering and Service www.hermanson.com TUK_SABEY_SEA CHILDRENS 1ST FL_v5_11 HERMANSON COMPANY LLP Space Input Data 09/06/2018 03:45PM 01-01 Office 1. General Details: Floor Area 125.0 ft2 Avg. Ceiling Height 9.0 ft Building Weight 70.0 Ib/ft2 1.1. OA Ventilation Requirements: Space Usage User -Defined OA Requirement 1 5.0 CFM/person OA Requirement 2 0.06 CFM/ft2 Space Usage Defaults ASHRAE Std 62.1-2010 2. Internals: 2.1. Overhead Lighting: Fixture Type Wattage Ballast Multiplier Schedule 2.2. Task Lighting: Wattage Schedule 2.3. Electrical Equipment: Wattage Schedule 3. Walls, Windows, Doors: Recessed (Unvented) 0.89 W/ft2 1.08 90.1 Office Lights/Elec 0.00 W/ft2 None 145.0 Watts 90.1 Office Lights/Elec 2.4. People: Occupancy Activity Level Sensible Latent Schedule 2.5. Miscellaneous Loads: Sensible Schedule Latent Schedule Exp. Wall Gross Area (ft2) Window 1 Qty. Window 2 Qty. Door 1 Qty. N 156.0 0 0 0 3.1. Cons ruction Types for Exposure N Wall Type 4. Roofs, Skylights: (No Roof or Skylight data). 5. Infiltration: Design Cooling Design Heating Energy Analysis Infiltration occurs at all hours. Existing Wall 0.00 CFM 0.00 ACH 0.00 CFM 6. Floors: Type Slab Floor On Grade Floor Area 0.0 ft2 Total Floor U -Value 0.420 BTU/(hrft2-°F) Exposed Perimeter 11.0 ft Edge Insulation R -Value 10.00 (hrft2•°F)/BTU 7. Partitions: (No partition data). 1.0 Person Office Work 245.0 BTU/hr/person 205.0 BTU/hr/person 90.1 Office Occupants 0 BTU/hr None 0 BTU/hr None Hourly Analysis Program v5.11 Page 1 of 10 TUK_SABEY_SEA CHILDRENS 1ST FL_v5_11 HERMANSON COMPANY LLP Space Input Data 09/06/2018 03:45PM 01-02 Conference 1. General Details: Floor Area 260.0 ft2 Avg. Ceiling Height 9.0 ft Building Weight 70.0 Ib/ft2 1.1. OA Ventilation Requirements: Space Usage User -Defined OA Requirement 1 5.0 CFM/person OA Requirement 2 0.06 CFM/ft2 Space Usage Defaults ASHRAE Std 62.1-2010 2. Internals: 2.1. Overhead Lighting: Fixture Type Wattage Ballast Multiplier Schedule 2.2. Task Lighting: Wattage Schedule 2.3. Electrical Equipment: Wattage Schedule 3. Walls, Windows, Doors: Recessed (Unvented) 0.89 W/ft2 1.08 90.1 Office Lights/Elec 0.00 W/ft2 None 145.0 Watts 90.1 Office Lights/Elec 2.4. People: Occupancy Activity Level Sensible Latent Schedule 2.5. Miscellaneous Loads: Sensible Schedule Latent Schedule Exp. Wall Gross Area (ft2) Window 1 Qty. Window 2 Qty. Door 1 Qty. N 318.0 0 0 0 3.1. Construction Types for Exposure N Wall Type 4. Roofs, Skylights: (No Roof or Skylight data). 5. Infiltration: Design Cooling Design Heating Energy Analysis Infiltration occurs at all hours. Existing Wall 0.00 CFM 0.00 ACH 0.00 CFM 6. Floors: Type Slab Floor On Grade Floor Area 0.0 ft2 Total Floor U -Value 0.420 BTU/(hrft2•°F) Exposed Perimeter 22.0 ft Edge Insulation R -Value 10.00 (hrft2•°F)/BTU 7. Partitions: (No partition data). 10.0 People Office Work 245.0 BTU/hr/person 205.0 BTU/hr/person 90.1 Office Occupants 0 BTU/hr None 0 BTU/hr None Hourly Analysis Program v5.11 Page 2 of 10 TUK_SABEY_SEA CHILDRENS 1ST FL_v5_11 HERMANSON COMPANY LLP Space Input Data 09/06/2018 03:45PM 01-03 Open Office 1. General Details: Floor Area 330.0 ft2 Avg. Ceiling Height 9.0 ft Building Weight 70.0 Ib/ft2 1.1. OA Ventilation Requirements: Space Usage User -Defined OA Requirement 1 5.0 CFM/person OA Requirement 2 0.06 CFM/ft2 Space Usage Defaults ASHRAE Std 62.1-2010 2. Internals: 2.1. Overhead Lighting: Fixture Type Wattage Ballast Multiplier Schedule 2.2. Task Lighting: Wattage Schedule 2.3. Electrical Equipment: Wattage Schedule 3. Walls, Windows, Doors: Recessed (Unvented) 0.89 W/ft2 1.08 90.1 Office Lights/Elec 0.00 W/ft2 None 1015.0 Watts 90.1 Office Lights/Elec 2.4. People: Occupancy Activity Level Sensible Latent Schedule 2.5. Miscellaneous Loads: Sensible Schedule Latent Schedule Exp. Wall Gross Area (ft2) Window 1 Qty. Window 2 Qty. Door 1 Qty. N 394.0 0 0 0 3.1. Construction Types for Exposure N Wall Type 4. Roofs, Skylights: (No Roof or Skylight data). Existing Wall 5. Infiltration: Design Cooling 0.00 CFM Design Heating 0.00 ACH Energy Analysis 0.00 CFM Infiltration occurs at all hours. 6. Floors: Type Slab Floor On Grade Floor Area 0.0 ft2 Total Floor U -Value 0.420 BTU/(hr•ft2•°F) Exposed Perimeter 27.0 ft Edge Insulation R -Value 10.00 (hr•ft2•°F)/BTU 7. Partitions: (No partition data). 7.0 People Office Work 245.0 BTU/hr/person 205.0 BTU/hr/person 90.1 Office Occupants 0 BTU/hr None 0 BTU/hr None Hourly Analysis Program v5.11 Page 3 of 10 TUK_SABEY_SEA CHILDRENS 1ST FL_v5_11 HERMANSON COMPANY LLP Space Input Data 09/06/2018 03:45PM 01-04 Hallway 1. General Details: Floor Area 110.0 ft2 Avg. Ceiling Height 9.0 ft Building Weight 70.0 Ib/ft2 1.1. OA Ventilation Requirements: Space Usage User -Defined OA Requirement 1 5.0 CFM/person OA Requirement 2 0.06 CFM/ft2 Space Usage Defaults ASHRAE Std 62.1-2010 2. Internals: 2.1. Overhead Lighting: Fixture Type Wattage Ballast Multiplier Schedule .. 2.2. Task Lighting: Wattage Schedule 2.3. Electrical Equipment: Wattage Schedule Recessed (Unvented) 0.89 W/ft2 1.08 90.1 Office Lights/Elec 0.00 W/ft2 None 0.0 Watts 90.1 Office Lights/Elec 3. Walls, Windows, Doors: (No Wall, Window, Door data). 4. Roofs, Skylights: (No Roof or Skylight data). 5. Infiltration: Design Cooling Design Heating Energy Analysis Infiltration occurs at all hours. 0.00 CFM 0.00 ACH 0.00 CFM 6. Floors: Type Slab Floor On Grade Floor Area 0.0 ft2 Total Floor U -Value 0.420 BTU/(hrft2•°F) Exposed Perimeter 0.0 ft Edge Insulation R -Value 10.00 (hrft2•°F)/BTU 7. Partitions: (No partition data). 2.4. People: Occupancy Activity Level Sensible Latent Schedule 2.5. Miscellaneous Loads: Sensible Schedule Latent Schedule 0.0 Person Office Work 245.0 BTU/hr/person 205.0 BTU/hr/person None 0 BTU/hr None 0 BTU/hr None Hourly Analysis Program v5.11 Page 4 of 10 TUK_SABEY_SEA CHILDRENS 1ST FL_v5_11 HERMANSON COMPANY LLP Space Input Data 09/06/2018 03:45PM 01-05 Open Office 1. General Details: Floor Area 935.0 ft2 Avg. Ceiling Height 9.0 ft Building Weight 70.0 lb/ft2 1.1. OA Ventilation Requirements: Space Usage ... User -Defined OA Requirement 1 5.0 CFM/person OA Requirement 2 0.06 CFM/ft2 Space Usage Defaults ASHRAE Std 62.1-2010 2. Internals: 2.1. Overhead Lighting: 2.4. People: Fixture Type Recessed (Unvented) Occupancy 11.0 People Wattage 0.89 W/ft2 Activity Level Office Work Ballast Multiplier 1.08 Sensible 245.0 BTU/hr/person Schedule 90.1 Office Lights/Elec Latent 205.0 BTU/hr/person Schedule 90.1 Office Occupants 2.2. Task Lighting: 2.5. Miscellaneous Loads: Wattage 0.00 W/ft2 Sensible 0 BTU/hr Schedule None Schedule None Latent 0 BTU/hr Schedule _ None 2.3. Electrical Equipment: Wattage Schedule 1600.0 Watts 90.1 Office Lights/Elec 3. Walls, Windows, Doors: (No Wall, Window, Door data). 4. Roofs, Skylights: (No Roof or Skylight data). 5. Infiltration: Design Cooling Design Heating Energy Analysis Infiltration occurs at all hours. 0.00 CFM 0.00 ACH 0.00 CFM 6. Floors: Type Slab Floor On Grade Floor Area 0.0 ft2 Total Floor U -Value 0.420 BTU/(hrft2•°F) Exposed Perimeter 0.0 ft Edge Insulation R -Value 10.00 (hrft2•°F)/BTU 7. Partitions: (No partition data). Hourly Analysis Program v5.11 Page 5 of 10 TUK_SABEY_SEA CHILDRENS 1ST FL_v5_11 HERMANSON COMPANY LLP Space Input Data 09/06/2018 03:45PM 02-01 Open Office 1. General Details: Floor Area 1154.0 ft2 Avg. Ceiling Height 9.0 ft Building Weight 70.0 lb/ft2 1.1. OA Ventilation Requirements: Space Usage User -Defined OA Requirement 1 5.0 CFM/person OA Requirement 2 0.06 CFM/ft2 Space Usage Defaults ASHRAE Std 62.1-2010 2. Internals: 2.1. Overhead Lighting: Fixture Type Wattage Ballast Multiplier Schedule 2.2. Task Lighting: Wattage Schedule 2.3. Electrical Equipment: Wattage Schedule Recessed (Unvented) 0.89 W/ft2 1.08 90.1 Office Lights/Elec 0.00 W/ft2 None 1.00 W/ft2 90.1 Office Lights/Elec 3. Walls, Windows, Doors: (No Wall, Window, Door data). 4. Roofs, Skylights: (No Roof or Skylight data). 5. Infiltration: Design Cooling Design Heating Energy Analysis Infiltration occurs at all hours. 6. Floors: Type Floor Area Total Floor U -Value Exposed Perimeter Edge Insulation R -Value 7. Partitions: (No partition data). 0.00 CFM 0.00 ACH 0.00 CFM Slab Floor On Grade 0.0 ft2 0.420 BTU/(hr•ft2•°F) 0.0 ft 10.00 (hr•ft2•°F)/BTU 2.4. People: Occupancy Activity Level Sensible Latent Schedule 2.5. Miscellaneous Loads: Sensible Schedule Latent Schedule 143.00 ft2/person Office Work 245.0 BTU/hr/person 205.0 BTU/hr/person 90.1 Office Occupants 0 BTU/hr None 0 BTU/hr None Hourly Analysis Program v5.11 Page 6 of 10 TUK_SABEY_SEA CHILDRENS 1ST FL_v5_11 HERMANSON COMPANY LLP Space Input Data 09/06/2018 03:45PM 03-01 Open Office 1. General Details: Floor Area 2393.0 ft2 Avg. Ceiling Height 9.0 ft Building Weight 70.0 lb/ft2 1.1. OA Ventilation Requirements: Space Usage User -Defined OA Requirement 1 5.0 CFM/person OA Requirement 2 0.06 CFM/ft2 Space Usage Defaults ASHRAE Std 62.1-2010 2. Internals: 2.1. Overhead Lighting: Fixture Type Wattage Ballast Multiplier Schedule 2.2. Task Lighting: Wattage Schedule 2.3. Electrical Equipment: Wattage Schedule Recessed (Unvented) 0.89 W/ft2 1.08 90.1 Office Lights/Elec 0.00 W/ft2 None 1.00 W/ft2 90.1 Office Lights/Elec 3. Walls, Windows, Doors: (No Wall, Window, Door data). 4. Roofs, Skylights: (No Roof or Skylight data). 5. Infiltration: Design Cooling Design Heating Energy Analysis Infiltration occurs at all hours. 0.00 CFM 0.00 ACH 0.00 CFM 6. Floors: Type Slab Floor On Grade Floor Area 0.0 ft2 Total Floor U -Value 0.420 BTU/(hrft2•°F) Exposed Perimeter 0.0 ft Edge Insulation R -Value 10.00 (hrft2•°F)/BTU 7. Partitions: (No partition data). 2.4. People: Occupancy Activity Level Sensible Latent Schedule 2.5. Miscellaneous Loads: Sensible Schedule Latent Schedule 143.00 ft2/person Office Work 245.0 BTU/hr/person 205.0 BTU/hr/person 90.1 Office Occupants 0 BTU/hr None 0 BTU/hr None Hourly Analysis Program v5.11 Page 7 of 10 TUK_SABEY_SEA CHILDRENS 1ST FL_v5_11 HERMANSON COMPANY LLP Space Input Data 09/06/2018 03:45PM 04-01 Open Office 1. General Details: Floor Area 734.0 ft' Avg. Ceiling Height 9.0 ft Building Weight 70.0 lb/ft' 1.1. OA Ventilation Requirements: Space Usage User -Defined OA Requirement 1 5.0 CFM/person OA Requirement 2 .. 0.06 CFM/ft2 Space Usage Defaults ASHRAE Std 62.1-2010 2. Internals: 2.1. Overhead Lighting: Fixture Type Wattage Ballast Multiplier Schedule 2.2. Task Lighting: Wattage Schedule 2.3. Electrical Equipment: Wattage Schedule Recessed (Unvented) 0.89 W/ft2 1.08 90.1 Office Lights/Elec 0.00 W/ft2 None 1.00 W/ft2 90.1 Office Lights/Elec 3. Walls, Windows, Doors: (No Wall, Window, Door data). 4. Roofs, Skylights: (No Roof or Skylight data). 5. Infiltration: Design Cooling Design Heating Energy Analysis Infiltration occurs at all hours. 0.00 CFM 0.00 ACH 0.00 CFM 6. Floors: Type Slab Floor On Grade Floor Area 0.0 ft' Total Floor U -Value 0.420 BTU/(hrft2•°F) Exposed Perimeter 0.0 ft Edge Insulation R -Value 10.00 (hrft2•°F)/BTU 7. Partitions: (No partition data). 2.4. People: Occupancy Activity Level Sensible Latent Schedule 2.5. Miscellaneous Loads: Sensible Schedule Latent Schedule 143.00 ft2/person Office Work 245.0 BTU/hr/person 205.0 BTU/hr/person 90.1 Office Occupants 0 BTU/hr None 0 BTU/hr None Hourly Analysis Program v5.11 Page 8 of 10 TUK_SABEY_SEA CHILDRENS 1ST FL_v5_11 HERMANSON COMPANY LLP Space Input Data 09/06/2018 03:45PM 05-01 Open Office 1. General Details: Floor Area 1451.0 ft2 Avg. Ceiling Height 9.0 ft Building Weight 70.0 Ib/ft2 1.1. OA Ventilation Requirements: Space Usage User -Defined OA Requirement 1 5.0 CFM/person OA Requirement 2 0.06 CFM/ft2 Space Usage Defaults ASHRAE Std 62.1-2010 2. Internals: 2.1. Overhead Lighting: Fixture Type Wattage Ballast Multiplier Schedule 2.2. Task Lighting: Wattage Schedule 2.3. Electrical Equipment: Wattage Schedule Recessed (Unvented) 0.89 W/ft2 1.08 90.1 Office Lights/Elec 0.00 W/ft2 None 1.00 W/ft2 90.1 Office Lights/Elec 3. Walls, Windows, Doors: (No Wall, Window, Door data). 4. Roofs, Skylights: (No Roof or Skylight data). 5. Infiltration: Design Cooling Design Heating Energy Analysis Infiltration occurs at all hours. 6. Floors: Type Floor Area Total Floor U -Value Exposed Perimeter Edge Insulation R -Value 7. Partitions: (No partition data). 0.00 CFM 0.00 ACH 0.00 CFM Slab Floor On Grade 0.0 ft2 0.420 BTU/(hr•ft2•°F) 0.0 ft 10.00 (hr•ft2•°F)/BTU 2.4. People: Occupancy Activity Level Sensible Latent Schedule 2.5. Miscellaneous Loads: Sensible Schedule Latent Schedule 143.00 ft2/person Office Work 245.0 BTU/hr/person 205.0 BTU/hr/person 90.1 Office Occupants 0 BTU/hr None 0 BTU/hr None Hourly Analysis Program v5.11 Page 9 of 10 TUK_SABEY_SEA CHILDRENS 1ST FL_v5_11 HERMANSON COMPANY LLP Space Input Data 09/06/2018 03:45PM 06-01 Open Office 1. General Details: Floor Area 1334.0 ft2 Avg. Ceiling Height 9.0 ft Building Weight 70.0 Ib/ft2 1.1. OA Ventilation Requirements: Space Usage User -Defined OA Requirement 1 5.0 CFM/person OA Requirement 2 0.06 CFM/ft2 Space Usage Defaults ASHRAE Std 62.1-2010 2. Internals: 2.1. Overhead Lighting: Fixture Type Wattage Ballast Multiplier Schedule 2.2. Task Lighting: Wattage Schedule 2.3. Electrical Equipment: Wattage Schedule Recessed (Unvented) 0.89 W/ft2 1.08 90.1 Office LightslElec 0.00 W/ft2 None 1.00 W/ft2 90.1 Office Lights/Elec 3. Walls, Windows, Doors: (No Wall, Window, Door data). 4. Roofs, Skylights: (No Roof or Skylight data). 5. Infiltration: Design Cooling Design Heating Energy Analysis Infiltration occurs at ail hours. 0.00 CFM 0.00 ACH 0.00 CFM 6. Floors: Type Slab Floor On Grade Floor Area 0.0 ft2 Total Floor U -Value . 0.420 BTU/(hrft2•°F) Exposed Perimeter 0.0 ft Edge Insulation R -Value 10.00 (hrft2•°F)/BTU 7. Partitions: (No partition data). 2.4. People: Occupancy Activity Level Sensible Latent Schedule 2.5. Miscellaneous Loads: Sensible Schedule Latent Schedule 143.00 ft2/person Office Work 245.0 BTU/hr/person 205.0 BTU/hr/person 90.1 Office Occupants 0 BTU/hr None 0 BTU/hr None Hourly Analysis Program v5.11 Page 10 of 10 ilHermanson Building Today, Defining Tomorrow Hermanson Company LLP 1221 2nd Avenue North Kent, WA 98032 tel 206-575-9700 fax 206-575-9800 Project: 3355 S 120th Place Tukwila, WA Date: 09/04/2018 Hermanson Building Today, Defining Tomorrow HVAC SYSTEM COOLING/HEATING CALCS CARRIER HAP VERSION: 5.11 SYSTEM INPUTS Mechanical Construction, Engineering and Service www.hermanson.com Project Name: TUK_SABEY_SEA CHILDRENS 1ST FL_v5_11 Prepared by: HERMANSON COMPANY LLP VAV Input Data 09/06/2018 03:44PM 1. General Details: Air System Name Equipment Type Air System Type Number of zones VAV Packaged Rooftop Units VAV 6 2. Ventilation System Components: Ventilation Air Data: Airflow Control Constant Ventilation Airflow Ventilation Sizing Method ASHRAE Std 62.1-2010 Unocc. Damper Position Closed Damper Leak Rate Outdoor Air CO2 Level 5 % 400 ppm Economizer Data: Control Integrated enthalpy control Upper Cutoff 75.0 °F Lower Cutoff 35.0 °F Central Cooling Data: Supply Air Temperature 55.0 °F Coil Bypass Factor 0.100 Cooling Source Air -Cooled DX Schedule JFMAMJJASOND Capacity Control Cycled or Staged Capacity - Fan On Supply Fan Data: Fan Type Configuration Fan Performance Overall Efficiency Forward Curved with Variable Frequency Drive Draw-thru 4.00 in wg 48 % % Airflow 100 90 80 70 60 50 % kW 100 77 60 44 35 25 % Airflow 40 30 20 10 0 %kW 19 13 9 7 6 Duct System Data: Supply Duct Data: Duct Heat Gain Duct Leakage Return Duct or Plenum Data: Return Air Via Wall Heat Gain to Plenum Roof Heat Gain to Plenum Lighting Heat Gain to Plenum 3. Zone Components: Space Assignments: 3 % 2 % Return Air Plenum 20 % 80 30 % Zone 1: Zone 1 01-02 Conference x1 Zone 2: Zone 2 01-01 Office x1 01-03 Open Office x1 01-04 Hallway x1 01-05 Open Office x1 Zone 3: Zone 3 03-01 Open Office x1 Zone 4: Zone 4 04-01 Open Office x1 Zone 5: Zone 5 05-01 Open Office x1 Zone 6: Zone 6 06-01 Open Office x1 Hourly Analysis Program 5.11 Page 1 of 3 VAV Input Data Project Name: TUK_SABEY_SEA CHILDRENS 1ST FL_v5_11 Prepared by: HERMANSON COMPANY LLP 09/06/2018 03:44PM Thermostats and Zone Data: Zone Cooling T-Stat Occ. (°F) Cooling T-Stat Unocc. (°F) Heating T-Stat Occ. (°F) Heating T-Stat Unocc. (°F) T-Stat Throttling Range (°F) Diversity Factor (%) Direct Exhaust Airflow (CFM) Direct Exhaust Fan (kW) 1 75.0 80.0 72.0 55.0 1.00 100 0.0 0.0 2 75.0 80.0 72.0 55.0 1.00 100 0.0 0.0 3 75.0 80.0 72.0 55.0 1.00 100 0.0 0.0 4 75.0 80.0 72.0 55.0 1.00 100 0.0 0.0 5 75.0 80.0 72.0 55.0 1.00 100 0.0 0.0 6 75.0 80.0 72.0 55.0 1.00 100 0.0 0.0 Thermostat Schedule Unoccupied Cooling is Supply Terminals Data: 90.1 Office HVAC Available Zone Terminal Type Air Distribution Air Distribution Effectiveness Specification Air Distribution Effectiveness Minimum Airflow Fan Performance Fan Efficiency Design Supply Temp. 1 Series FPMBX with reheat Ceiling supply / ceiling retum ASHRAE 62.1 <auto> 30 % 0.30 in wg 70 % 86.9 °F 2 Series FPMBX with reheat Ceiling supply / ceiling return ASHRAE 62.1 <auto> 30 % 0.30 in wg 70 % 78.0 °F 3 Series FPMBX with reheat Ceiling supply / ceiling return ASHRAE 62.1 <auto> 30 % 0.30 in wg ° 70 /° 86.9 °F 4 Series FPMBX with reheat Ceiling supply / ceiling retum ASHRAE 62.1 <auto> 30 % 0.30 in wg 70 % 86.9 °F 5 Series FPMBX with reheat Ceiling supply / ceiling return ASHRAE 62.1 <auto> 30 % 0.30 in wg 70 % 86.9 °F 6 Series FPMBX with reheat Ceiling supply / ceiling retum ASHRAE 62.1 <auto> 30 % 0.30 in wg 70 % 86.9 °F Reheat Coil Source Reheat Coil Schedule Zone Heating Units: Zone Unit Heat Source Zone Heating Unit Schedule 4. Sizing Data (Computer -Generated): System Sizing Data: Sizing Data: Cooling Supply Temperature Supply Fan Airflow Ventilation Airflow Hydronic Sizing Specifications: Chilled Water Delta -T Hot Water Delta -T Safety Factors: Cooling Sensible Cooling Latent Heating Zone Sizing Data: Zone Airflow Sizing Method Space Airflow Sizing Method Electric Resistance JFMAMJJASOND Electric Resistance JFMAMJJASOND 55.0 °F 3003.2 CFM 876.2 CFM 10.0 °F 30.0 °F 0 0 % 0 Peak zone sensible load Individual peak space Toads Zone Supply Airflow (CFM) Zone Htg Unit (MBH) Reheat Coil (MBH) FPMBX Fan (CFM) 1 167.2 - 3.8 167.2 Hourly Analysis Program 5.11 Page 2 of 3 VAV Input Data Project Name: TUK_SABEY_SEA CHILDRENS 1ST FL_v5_11 09/06/2018 Prepared by: HERMANSON COMPANY LLP 03:44PM Zone Supply Airflow (CFM) Zone Htg Unit (MBH) Reheat Coil (MBH) FPMBX Fan (CFM) 2 809.7 - 9.6 809.7 3 795.9 - 16.9 795.9 4 244.1 - 5.2 244.1 5 482.6 - 10.3 482.6 6 443.7 - 9.4 443.7 5. Equipment Data Central Cooling Unit - Air -Cooled DX Estimated Maximum Load Design OAT Equipment Sizing Gross Cooling Capacity Compressor & OD Fan Power Conventional Cutoff OAT Low Temperature Operation 116.0 MBH 95.0 °F User -Defined 1.0 MBH 1.000 kW 55.0 °F Not used Hourly Analysis Program 5.11 Page 3 of 3 Hermanson Building Today, Defining Tomorrow Hermanson Company LLP 1221 2nd Avenue North Kent, WA 98032 tel 206-575-9700 fax 206-575-9800 Project: 3355 S 120th Place Tukwila, WA Date: 09/04/2018 //7 Hermanson Building Today, Defining Tomorrow HVAC SYSTEM COOLING/HEATING CALCS CARRIER HAP VERSION: 5.11 SYSTEM OUTPUTS Mechanical Construction, Engineering and Service www.hermanson.com Air System Sizing Summary for VAV Project Name: TUK_SABEY_SEA CHILDRENS 1ST FL_v5_11 09/06/2018 Prepared by: HERMANSON COMPANY LLP 03:45PM Air System Information Air System Name Equipment Class Air System Type VAV PKG ROOF VAV Sizing Calculation Information Calculation Months Jan to Dec Sizing Data Calculated Number of zones Floor Area Location Zone CFM Sizing Space CFM Sizing 6 7672.0 ft2 Seattle IAP, Washington Peak zone sensible load Individual peak space loads Central Cooling Coil Sizing Data Total coil load 9.7 Tons Load occurs at Jul 1500 Total coil load 116.0 MBH OA DB / WB .. 86.0 / 67.0 °F Sensible coil load 94.9 MBH Entering DB / WB . 81.0 / 63.8 °F Coil CFM at Jul 1500 3000 CFM Leaving DB / WB 51.3 / 49.8 °F Max block CFM at Jul 2100 3003 CFM Coil ADP 48.0 °F Sum of peak zone CFM 3003 CFM Bypass Factor 0.100 Sensible heat ratio 0.818 Resulting RH 42 CFM/Ton 310.4 Design supply temp. 55.0 °F ft2/Ton 793.7 Zone T -stat Check 1 of 6 OK BTU/(hrft2) 15.1 Max zone temperature deviation 1.3 °F Water flow @ 10.0 °F rise N/A Supply Fan Sizing Data Actual max CFM at Jul 2100 Standard CFM Actual max CFM/ft2 3003 CFM 2955 CFM 0.39 CFM/ft2 Fan motor BHP Fan motor kW Fan static 3.70 BHP 2.94 kW 4.00 in wg Outdoor Ventilation Air Data Design airflow CFM 876 CFM CFM/person 12.46 CFM/person CFM/ft2 0.11 CFM/ft2 Hourly Analysis Program 5.11 Page 1 of 20 Zone Sizing Summary for VAV Project Name: TUK_SABEY_SEA CHILDRENS 1ST FL_v5_11 Prepared by: HERMANSON COMPANY LLP 09/06/2018 03:45PM Air System Information Air System Name Equipment Class Air System Type VAV PKG ROOF VAV Sizing Calculation Information Calculation Months Jan to Dec Sizing Data Calculated Zone Terminal Sizing Data Number of zones Floor Area Location 6 7672.0 ft2 Seattle IAP, Washington Zone CFM Sizing Peak zone sensible load Space CFM Sizing Individual peak space loads Zone Name Design Supply Airflow (CFM) Minimum Supply Airflow (CFM) Zone CFM/ft2 Reheat Coil Load (MBH) Reheat Coil Water gpm @ 30.0 °F Zone Htg Unit Coil Load (MBH) Zone Htg Unit Water gpm @ 30.0 °F Mixing Box Fan Airflow (CFM) Zone 1 167 66 0.64 3.8 - 0.0 - 167 Zone 2 810 243 0.54 9.6 - 0.0 - 810 Zone 3 796 239 0.33 16.9 - 0.0 - 796 Zone 4 244 73 0.33 5.2 - 0.0 - 244 Zone 5 483 145 0.33 10.3 - 0.0 - 483 Zone 6 444 133 0.33 9.4 - 0.0 - 444 Zone Peak Sensible Loads Zone Name Zone Cooling Sensible (MBH) Time of Peak Sensible. Cooling Load Zone Heating Load (MBH) Zone Floor Area (ft2) Zone 1 3.5 Jul 2100 1.7 260.0 Zone 2 17.1 Jul 2100 3.0 1500.0 Zone 3 16.8 Jan 2100 0.0 2393.0 Zone 4 5.1 Jan 2100 0.0 734.0 Zone 5 10.2 Jan 2100 0.0 1451.0 Zone 6 9.4 Jan 2100 0.0 1334.0 Space Loads and Airflows Zone Name / Space Name Mult. Cooling Sensible (MBH) Time of Peak Sensible Load Air Flow (CFM) Heating Load (MBH) Floor Area (ft2) Space CFM/ft2 Zone 1 01-02 Conference 1 3.5 Jul 2100 167 1.7 260.0 0.64 Zone 2 01-01 Office 1 1.1 Jul 2100 53 0.9 125.0 0.42 01-03 Open Office 1 6.0 Jul 2100 284 2.2 330.0 0.86 01-04 Hallway 1 0.2 Jan 2200 11 0.0 110.0 0.10 01-05 Open Office 1 9.7 Jan 2100 462 0.0 935.0 0.49 Zone 3 03-01 Open Office 1 16.8 Jan 2100 796 0.0 2393.0 0.33 Zone 4 04-01 Open Office 1 5.1 Jan 2100 244 0.0 734.0 0.33 Zone 5 05-01 Open Office 1 10.2 Jan 2100 483 0.0 1451.0 0.33 Zone 6 06-01 Open Office 1 9.4 Jan 2100 444 0.0 1334.0 0.33 Hourly Analysis Program 5.11 Page 2 of 20 1.1:9 weJ6oJd sisAleuy AIJnoH OZ JO E abed 'Totals (incl. Space Multipliers) 1 06-01 Open Office N 0 3 (o en 1 05-01 Open Office 1 Zone 5 04-01 Open Office Zone 4 03-01 Open Office Zone 3 01-05 Open Office 01-04 Hallway 01-03 Open Office 01-01 Office Zone 2 01-02 Conference Zone 1 'Zone Name / Space Name 3 c_ (o 0 1331 UA) W N CCD - (WD V 01 0) 00) a N. Minimum Supply Air (CFM) C.) A O 1451.0 734.0 2393.0 1 935.0 O O 330.0 125.0 260.0 D r.. Space Floor Area (ft2) O 00) O 00) O 00) co 00) O 00) O 00) O 00) O 00) O 00) (Ra) Area Outdoor Air Rate (CFM/ft2) (D W O - Cas — 0) V --, 0 o 0 -4 0 -, 0 O O D N. Time Averaged Occupancy (Occupants) CT O O 5.00 5.00 5.00 5.00 Cas O O 5.00 5.00 01 O O (Rp) People Outdoor Air Rate (CFM/person) O b O O O O O O 1.0 (Ez) Air Distribution Effectiveness 127 138 N d ....< 1 0( W 0) - N0 .... Space Outdoor Air (CFM) 812 127 03 0 2271 U v V W 0...,0))Cr < N. Breathing Zone Outdoor Air (CFM) O CO N d 0 (D V 0) O (D V 0) O (D V 0) O (D V 0) O A 0) 0.9271 _ CO 1.0521 0.9441 (Evz)1 Space Ventilation Efficiency N n) ▪ a rn o o com o o m occas -•3 � O o3vov2 ><g .0 m • _ CD o o Q 3 --aOa� -ot .. C '. -. K7r0 N. c co O 3 . M°^ CD > °FD- o 3 3 a R O 01 CA A- „5.. -R 0 c 7 N J. 0 Cf N O � p .a O N co (O CO O= O d N -s 00 0) N 0 n 0 m m 0 CD W O GJ) O oz. Ventilation Sizing Summary for VAV Air System Design Load Summary for VAV Project Name: TUK_SABEY_SEA CHILDRENS 1ST FL_v5_11 Prepared by: HERMANSON COMPANY LLP 09/06/2018 03:45PM Hourly Analysis Program 5.11 Page 4 of 20 DESIGN COOLING DESIGN HEATING COOLING DATA AT Jul 1500 COOLING OA DB / WB 86.0 °F / 67.0 °F HEATING DATA AT DES HTG HEATING OA DB / WB 24.0 °F / 19.2 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 0 ft2 0 - 0 ft2 - - Wall Transmission 868 ft2 479 - 868 ft2 4764 - Roof Transmission 0 ft2 0 - 0 ft2 0 - Window Transmission 0 ft2 0 - 0 ft2 0 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 0 ft2 0 - 0 ft2 0 - Floor Transmission 0 ft2 0 - 0 ft2 0 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 7374 W 16024 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 8817 W 28873 - 0 0 - People 70 14494 14420 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 59870 14420 - 4764 0 Zone Conditioning- 68868 14420 - 2776 0 Plenum Wall Load 20% 120 - 0 0 - Plenum Roof Load 80% 0 - 0 0 - Plenum Lighting Load 30% 7548 - 0 0 - Return Fan Load 3000 CFM 0 - 917 CFM 0 - Ventilation Load 876 CFM 6510 6695 876 CFM 41776 0 Supply Fan Load 3000 CFM 9996 - 917 CFM -1334 - Space Fan Coil Fans- 505 - - -505 - Duct Heat Gain / Loss 3% 1796 - 3% 143 - » Total System Loads - 95343 21116 - 42855 0 Central Cooling Coil- 94878 21120 - 0 0 Terminal Reheat Coils - 0 -- 42291 - » Total Conditioning - 94878 21120 - 42291 0 Key: Positive values are clg loads Negative values are htg loads Positive values are htg loads Negative values are clg loads Hourly Analysis Program 5.11 Page 4 of 20 Zone Design Load Summary for VAV Project Name: TUK_SABEY_SEA CHILDRENS 1ST FL_v5_11 Prepared by: HERMANSON COMPANY LLP 09/06/2018 03:45PM Zone 1 DESIGN COOLING DESIGN HEATING COOLING DATA AT Jul 2100 COOLING OA DB / WB 75.4 °F / 63.6 °F HEATING DATA AT DES HTG HEATING OA DB / WB 24.0 °F / 19.2 °F OCCUPIED T -STAT 75.0 °F OCCUPIED T -STAT 72.0 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 0 ft2 0 - 0 ft2 - - Wall Transmission 318 ft2 291 - 318 ft2 1745 - Roof Transmission 0 ft2 0 - 0 ft2 0 - Window Transmission 0 ft2 0 - 0 ft2 0 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 0 ft2 0 - 0 ft2 0 - Floor Transmission 0 ft2 0 - 0 ft2 0 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 250 W 561 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 145 W 481 - 0 0 - People 10 2191 2050 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 3525 2050 - 1745 0 Zone 2 DESIGN COOLING DESIGN HEATING COOLING DATA AT Jul 2100 COOLING OA DB / WB 75.4 °F / 63.6 °F HEATING DATA AT DES HTG HEATING OA DB / WB 24.0 °F / 19.2 °F OCCUPIED T -STAT 75.0 °F OCCUPIED T -STAT 72.0 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 0 ft2 0 - 0 ft2 - - Wall Transmission 550 ft2 504 - 550 ft2 3019 - Roof Transmission 0 ft2 0 - 0 ft2 0 - Window Transmission 0 ft2 0 - 0 ft2 0 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 0 ft2 0 - 0 ft2 0 - Floor Transmission 0 ft2 0 - 0 ft2 0 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 1442 W 3237 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 2760 W 9165 - 0 0 - People 19 4163 3895 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 17069 3895 - 3019 0 Hourly Analysis Program 5.11 Page 5 of 20 Zone Design Load Summary for VAV Project Name: TUK_SABEY_SEA CHILDRENS 1ST FL_v5_11 Prepared by: HERMANSON COMPANY LLP 09/06/2018 03:45PM Zone 3 DESIGN COOLING DESIGN HEATING COOLING DATA AT Jan 2100 COOLING OA DB / WB 59.2 °F / 52.5 °F HEATING DATA AT DES HTG HEATING OA DB / WB 24.0 °F / 19.2 °F OCCUPIED T -STAT 75.0 °F OCCUPIED T -STAT 72.0 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 0 ft2 0 - 0 ft2 - - Wall Transmission 0 ft2 0 - 0 ft2 0 - Roof Transmission 0 ft2 0 - 0 ft2 0 - Window Transmission 0 ft2 0 - 0 ft2 0 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 0 ft2 0 - 0 ft2 0 - Floor Transmission 0 ft2 0 - 0 ft2 0 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 2300 W 5164 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 2393 W 7946 - 0 0 - People 17 3666 3431 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 16777 3431 - 0 0 Zone 4 DESIGN COOLING DESIGN HEATING COOLING DATA AT Jan 2100 COOLING OA DB / WB 59.2 °F / 52.5 °F HEATING DATA AT DES HTG HEATING OA DB / WB 24.0 °F / 19.2 °F OCCUPIED T -STAT 75.0 °F OCCUPIED T -STAT 72.0 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 0 ft2 0 - 0 ft2 - - Wall Transmission 0 ft2 0 - 0 ft2 0 - Roof Transmission 0 ft2 0 - 0 ft2 0 - Window Transmission 0 ft2 0 - 0 ft2 0 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 0 ft2 0 - 0 ft2 0 - Floor Transmission 0 ft2 0 - 0 ft2 0 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 706 W 1584 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 734 W 2437 - 0 0 - People 5 1125 1052 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous -0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 5146 1052 - 0 0 Hourly Analysis Program 5.11 Page 6 of 20 Zone Design Load Summary for VAV Project Name: TUK_SABEYSEA CHILDRENS 1ST FL_v5_11 Prepared by: HERMANSON COMPANY LLP 09/06/2018 03:45PM Zone 5 DESIGN COOLING DESIGN HEATING COOLING DATA AT Jan 2100 COOLING OA DB / WB 59.2 °F / 52.5 °F HEATING DATA AT DES HTG HEATING OA DB / WB 24.0 °F / 19.2 °F OCCUPIED T -STAT 75.0 °F OCCUPIED T -STAT 72.0 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTUIhr) Window & Skylight Solar Loads 0 ft2 0 - 0 ft2 - - Wall Transmission 0 ft2 0 - 0 ft2 0 - Roof Transmission 0 ft2 0 - 0 ft2 0 - Window Transmission 0 ft2 0 - 0 ft2 0 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 0 ft2 0 - 0 ft2 0 - Floor Transmission 0 ft2 0 - 0 ft2 0 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 1395 W 3131 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 1451 W 4818 - 0 0 - People 10 2223 2080 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 10173 2080 - 0 0 Zone 6 DESIGN COOLING DESIGN HEATING COOLING DATA AT Jan 2100 COOLING OA DB / WB 59.2 °F / 52.5 °F HEATING DATA AT DES HTG HEATING OA DB / WB 24.0 °F / 19.2 °F OCCUPIED T -STAT 75.0 °F OCCUPIED T -STAT 72.0 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 0 ft2 0 - 0 ft2 - - Wall Transmission 0 ft2 0 - 0 ft2 0 - Roof Transmission 0 ft 0 - 0 ft2 0 - Window Transmission 0 ft2 0 - 0 ft2 0 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 0 ft2 0 - 0 ft2 0 - Floor Transmission 0 ft2 0 - 0 ft2 0 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 1282 W 2879 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 1334 W 4430 - 0 0 - People 9 2044 1912 0 0 0 Infiltration- 0 0 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 9352 1912 - 0 0 Hourly Analysis Program 5.11 Page 7 of 20 Space Design Load Summary for VAV Project Name: TUK_SABEY_SEA CHILDRENS 1ST FL_v5_11 Prepared by: HERMANSON COMPANY LLP 09/06/2018 03:45PM TABLE 1.1.A. Component Loads For Space "01-02 Conference" In Zone "Zone 1" DESIGN COOLING DESIGN HEATING COOLING DATA AT Jul 2100 COOLING OA DB / WB 75.4 °F / 63.6 °F OCCUPIED T -STAT 75.0 °F HEATING DATA AT DES HTG HEATING OA DB / WB 24.0 °F / 19.2 °F OCCUPIED T -STAT 72.0 °F HEATING Sensible Latent Shade Sensible Latent SPACE LOADS Details (BTU/hr) (BTU/hr) Details (BTU/hr) (BTU/hr) Window & Skylight Solar Loads 0 ft2 0 - 0 ft2 - - Wall Transmission 318 ft2 291 - 318 ft2 1745 - Roof Transmission 0 ft2 0 - 0 ft2 0 - Window Transmission 0 ft2 0 - 0 ft2 0 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 0 ft2 0 - 0 ft2 0 - Floor Transmission 0 ft2 0 - 0 ft2 0 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 250 W 561 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 145 W 481 - 0 0 - People 10 2191 2050 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 3525 2050 - 1745 0 TABLE 1.1.B. Envelope Loads For Space "01-02 Conference" In Zone "Zone 1" COOLING COOLING HEATING Area U -Value Shade TRANS SOLAR TRANS (ft2) (BTU/(hrft2•°F)) Coeff. (BTU/hr) (BTU/hr) (BTU/hr) N EXPOSURE WALL 318 0.114 - 291 - 1745 Hourly Analysis Program 5.11 Page 8 of 20 Space Design Load Summary for VAV Project Name: TUK_SABEY SEA CHILDRENS 1ST FL_v5_11 Prepared by: HERMANSON COMPANY LLP 09/06/2018 03:45PM TABLE 2.1.A. Component Loads For Space "01-01 Office" In Zone "Zone 2" DESIGN COOLING DESIGN HEATING COOLING DATA AT Jul 2100 COOLING OA DB / WB 75.4 °F / 63.6 °F OCCUPIED T -STAT 75.0 °F HEATING DATA AT DES HTG HEATING OA DB / WB 24.0 °F / 19.2 °F OCCUPIED T -STAT 72.0 °F HEATING Sensible Latent Shade Sensible Latent SPACE LOADS Details (BTU/hr) (BTU/hr) Details (BTU/hr) (BTU/hr) Window & Skylight Solar Loads 0 ft' 0 - 0 ft' - - Wall Transmission 156 ft' 143 - 156 ft2 856 - Roof Transmission 0 ft2 0 - 0 ft' 0 - Window Transmission 0 ft' 0 - 0 ft' 0 - Skylight Transmission 0 ft2 0 - 0 ft' 0 - Door Loads 0 ft' 0 - 0 ft' 0 - Floor Transmission 0 ft' 0 - 0 ft' 0 - Partitions 0 ft' 0 - 0 ft' 0 - Ceiling 0 ft2 0 - 0 ft' 0 - Overhead Lighting 120 W 270 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 145 W 481 - 0 0 - People 1 219 205 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 1113 205 - 856 0 TABLE 2.1.B. Envelope Loads For Space "01-01 Office' In Zone "Zone 2" COOLING COOLING HEATING Area U -Value Shade TRANS SOLAR TRANS (ft2) (BTU/(hr•ft2•°F)) Coeff. (BTU/hr) (BTU/hr) (BTU/hr) N EXPOSURE WALL 156 0.114 - 143 - 856 Hourly Analysis Program 5.11 Page 9 of 20 Space Design Load Summary for VAV Project Name: TUK_SABEY_SEA CHILDRENS 1ST FL_v5_11 Prepared by: HERMANSON COMPANY LLP 09/06/2018 03:45PM TABLE 2.2.A. Component Loads For Space "01-03 Open Office" In Zone "Zone 2" DESIGN COOLING DESIGN HEATING COOLING DATA AT Jul 2100 COOLING OA DB / WB 75.4 °F / 63.6 °F OCCUPIED T -STAT 75.0 °F HEATING DATA AT DES HTG HEATING OA DB / WB 24.0 °F / 19.2 °F OCCUPIED T -STAT 72.0 °F HEATING Sensible Latent Shade Sensible Latent SPACE LOADS Details (BTU/hr) (BTU/hr) Details (BTU/hr) (BTU/hr) Window & Skylight Solar Loads 0 ft2 0 - 0 ft2 - - Wall Transmission 394 ft2 361 - 394 ft2 2163 - Roof Transmission 0 ft2 0 - 0 ft2 0 - Window Transmission 0 ft2 0 - 0 ft2 0 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 0 ft2 0 - 0 ft2 0 - Floor Transmission 0 ft2 0 - 0 ft2 0 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 317 W 712 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 1015 W 3370 - 0 0 - People 7 1534 1435 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 5977 1435 - 2163 0 TABLE 2.2.B. Envelope Loads For Space "01-03 Open Office" In Zone "Zone 2" COOLING COOLING HEATING Area U -Value Shade TRANS SOLAR TRANS (ft2) (BTU/(hrft2.°F)) Coeff. (BTU/hr) (BTU/hr) (BTU/hr) N EXPOSURE WALL 394 0.114 - 361 - 2163 Hourly Analysis Program 5.11 Page 10 of 20 Space Design Load Summary for VAV Project Name: TUK_SABEY_SEA CHILDRENS 1ST FL_v5_11 Prepared by: HERMANSON COMPANY LLP 09/06/2018 03:45PM TABLE 2.3.A. Component Loads For Space "01-04 Hallway" In Zone "Zone 2" " In Zone "Zone 2" DESIGN COOLING DESIGN HEATING COOLING DATA AT Jan 2200 COOLING OA DB / WB 57.4 °F / 51.8 °F OCCUPIED T -STAT 75.0 °F HEATING DATA AT DES HTG HEATING OA DB / WB 24.0 °F / 19.2 °F OCCUPIED T -STAT 72.0 °F COOLING HEATING Sensible Latent U -Value Sensible Latent SPACE LOADS Details (BTU/hr) (BTU/hr) Details (BTU/hr) (BTU/hr) Window & Skylight Solar Loads 0 ft2 0 - 0 ft2 - - Wall Transmission 0 ft2 0 - 0 ft2 0 - Roof Transmission 0 ft2 0 - 0 ft2 0 - Window Transmission 0 ft2 0 - 0 ft2 0 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 0 ft2 0 - 0 ft2 0 - Floor Transmission 0 ft2 0 - 0 ft2 0 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 106 W 238 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 0 W 0 - 0 0 - People 0 0 0 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 238 0 - 0 0 TABLE 2.3.B. Envelope Loads For Space "01-04 Hallwa " In Zone "Zone 2" COOLING COOLING HEATING Area U -Value Shade TRANS SOLAR TRANS (ft2) (BTU/(hr•ft2•°F)) Coeff. (BTU/hr) (BTU/hr) (BTU/hr) Hourly Analysis Program 5.11 Page 11 of 20 Space Design Load Summary for VAV Project Name: TUK_SABEY_SEA CHILDRENS 1ST FL_v5_11 Prepared by: HERMANSON COMPANY LLP 09/06/2018 03:45PM TABLE 2.4.A. Component Loads For Space "01-05 Open Office" In Zone "Zone 2" DESIGN COOLING DESIGN HEATING COOLING DATA AT Jan 2100 COOLING OA DB / WB 59.2 °F / 52.5 °F OCCUPIED T -STAT 75.0 °F HEATING DATA AT DES HTG HEATING OA DB / WB 24.0 °F / 19.2 °F OCCUPIED T -STAT 72.0 °F HEATING Sensible Latent Shade Sensible Latent SPACE LOADS Details (BTU/hr) (BTU/hr) Details (BTU/hr) (BTU/hr) Window & Skylight Solar Loads 0 ft2 0 - 0 ft2 - - Wall Transmission 0 ft2 0 - 0 ft2 0 - Roof Transmission 0 ft2 0 - 0 ft2 0 - Window Transmission 0 ft2 0 - 0 ft2 0 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 0 ft2 0 - 0 ft2 0 - Floor Transmission 0 ft2 0 - 0 ft2 0 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 899 W 2018 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 1600 W 5313 - 0 0 - People 11 2410 2255 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 9741 2255 - 0 0 TABLE 2.4.B. Envelope Loads For Space "01-05 Open Office" In Zone "Zone 2" COOLING COOLING HEATING Area U -Value Shade TRANS SOLAR TRANS (ft2) (BTU/(hr.ft2•°F)) Coeff. (BTU/hr) (BTU/hr) (BTU/hr) Hourly Analysis Program 5.11 Page 12 of 20 Space Design Load Summary for VAV Project Name: TUK_SABEY_SEA CHILDRENS 1ST FL_v5_11 Prepared by: HERMANSON COMPANY LLP 09/06/2018 03:45PM TABLE 3.1.A. Component Loads For Space "03-01 Open Office" In Zone "Zone 3" DESIGN COOLING DESIGN HEATING COOLING DATA AT Jan 2100 COOLING OA DB / WB 59.2 °F / 52.5 °F OCCUPIED T -STAT 75.0 °F HEATING DATA AT DES HTG HEATING OA DB / WB 24.0 °F / 19.2 °F OCCUPIED T -STAT 72.0 °F HEATING Sensible Latent Shade Sensible Latent SPACE LOADS Details (BTU/hr) (BTU/hr) Details (BTU/hr) (BTU/hr) Window & Skylight Solar Loads 0 ft2 0 - 0 ft2 - - Wall Transmission 0 ft2 0 - 0 ft2 0 - Roof Transmission 0 ft2 0 - 0 ft2 0 - Window Transmission 0 ft2 0 - 0 ft2 0 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 0 ft2 0 - 0 ft2 0 - Floor Transmission 0 ft2 0 - 0 ft2 0 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 2300 W 5164 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 2393 W 7946 - 0 0 - People 17 3666 3431 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 16777 3431 - 0 0 TABLE 3.1.B. Envelope Loads For Space "03-01 Open Office" In Zone "Zone 3" COOLING COOLING HEATING Area U -Value Shade TRANS SOLAR TRANS (ft2) (BTU/(hr•ft2•°F)) Coeff. (BTU/hr) (BTU/hr) (BTU/hr) Hourly Analysis Program 5.11 Page 13 of 20 Space Design Load Summary for VAV Project Name: TUK_SABEY_SEA CHILDRENS 1ST FL_v5_11 Prepared by: HERMANSON COMPANY LLP 09/06/2018 03:45PM TABLE 4.1.A. Component Loads For Space "04-01 Open Office" In Zone "Zone 4" DESIGN COOLING DESIGN HEATING COOLING DATA AT Jan 2100 COOLING OA DB / WB 59.2 °F / 52.5 °F OCCUPIED T -STAT 75.0 °F HEATING DATA AT DES HTG HEATING OA DB / WB 24.0 °F / 19.2 °F OCCUPIED T -STAT 72.0 °F HEATING Sensible Latent Shade Sensible Latent SPACE LOADS Details (BTU/hr) (BTU/hr) Details (BTU/hr) (BTU/hr) Window & Skylight Solar Loads 0 ft2 0 - 0 ft2 - - Wall Transmission 0 ft2 0 - 0 ft2 0 - Roof Transmission 0 ft2 0 - 0 ft2 0 - Window Transmission 0 ft2 0 - 0 ft2 0 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 0 ft2 0 - 0 ft2 0 - Floor Transmission 0 ft2 0 - 0 ft2 0 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 706 W 1584 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 734 W 2437 - 0 0 - People 5 1125 1052 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 5146 1052 - 0 0 TABLE 4.1.B. Envelope Loads For Space "04-01 Open Office" In Zone "Zone 4" COOLING COOLING HEATING Area U -Value Shade TRANS SOLAR TRANS (ft2) (BTU/(hr•ft2•°F)) Coeff. (BTU/hr) (BTU/hr) (BTU/hr) Hourly Analysis Program 5.11 Page 14 of 20 Space Design Load Summary for VAV Project Name: TUK_SABEY_SEA CHILDRENS 1ST FL_v5_11 Prepared by: HERMANSON COMPANY LLP 09/06/2018 03:45PM TABLE 5.1.A. Component Loads For Space "05-01 Open Office" In Zone "Zone 5" DESIGN COOLING DESIGN HEATING COOLING DATA AT Jan 2100 COOLING OA DB / WB 59.2 °F / 52.5 °F OCCUPIED T -STAT 75.0 °F HEATING DATA AT DES HTG HEATING OA DB / WB 24.0 °F / 19.2 °F OCCUPIED T -STAT 72.0 °F HEATING Sensible Latent Shade Sensible Latent SPACE LOADS Details (BTU/hr) (BTU/hr) Details (BTU/hr) (BTU/hr) Window & Skylight Solar Loads 0 ft2 0 - 0 ft2 - - Wall Transmission 0 ft2 0 - 0 ft2 0 - Roof Transmission 0 ft2 0 - 0 ft2 0 - Window Transmission 0 ft2 0 - 0 ft2 0 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 0 ft2 0 - 0 ft2 0 - Floor Transmission 0 ft2 0 - 0 ft2 0 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 1395 W 3131 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 1451 W 4818 - 0 0 - People 10 2223 2080 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 10173 2080 - 0 0 TABLE 5.1.B. Envelope Loads For Space "05-01 Open Office" In Zone "Zone 5" COOLING COOLING HEATING Area U -Value Shade TRANS SOLAR TRANS (ft2) (BTU/(hr•ft2•°F)) Coeff. (BTU/hr) (BTU/hr) (BTU/hr) Hourly Analysis Program 5.11 Page 15 of 20 Space Design Load Summary for VAV Project Name: TUK_SABEY_SEA CHILDRENS 1ST FL_v5_11 Prepared by: HERMANSON COMPANY LLP 09/06/2018 03:45PM TABLE 6.1.A. Component Loads For Space "06-01 Open Office" In Zone "Zone 6" DESIGN COOLING DESIGN HEATING COOLING DATA AT Jan 2100 COOLING OA DB / WB 59.2 °F / 52.5 °F OCCUPIED T -STAT 75.0 °F HEATING DATA AT DES HTG HEATING OA DB / WB 24.0 °F / 19.2 °F OCCUPIED T -STAT 72.0 °F HEATING Sensible Latent Shade Sensible Latent SPACE LOADS Details (BTU/hr) (BTU/hr) Details (BTU/hr) (BTU/hr) Window & Skylight Solar Loads 0 ft2 0 - 0 ft2 - - Wall Transmission 0 ft2 0 - 0 ft2 0 - Roof Transmission 0 ft2 0 - 0 ft2 0 - Window Transmission 0 ft2 0 - 0 ft2 0 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 0 ft2 0 - 0 ft2 0 - Floor Transmission 0 ft2 0 - 0 ft2 0 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 1282 W 2879 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 1334 W 4430 - 0 0 - People 9 2044 1912 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 9352 1912 - 0 0 TABLE 6.1.B. Envelope Loads For Space "06-01 Open Office" In Zone "Zone 6" COOLING COOLING HEATING Area U -Value Shade TRANS SOLAR TRANS (ft2) (BTU/(hr•ft2•°F)) Coeff. (BTU/hr) (BTU/hr) (BTU/hr) Hourly Analysis Program 5.11 Page 16 of 20 System Psychrometrics for VAV Project Name: TUK_SABEY_SEA CHILDRENS 1ST FL_v5_11 Prepared by: HERMANSON COMPANY LLP 09/06/2018 03:45PM July DESIGN COOLING DAY, 1500 TABLE 1: SYSTEM DATA Component Location Dry -Bulb Temp (°F) Specific Humidity (Ib/Ib) Airflow (CFM) CO2 Level (ppm) Sensible Heat (BTU/hr) Latent Heat (BTU/hr) Ventilation Air Inlet 86.0 0.01002 876 400 6510 6695 Vent - Return Mixing Outlet 81.0 0.00886 3000 1064 - - Central Cooling Coil Outlet 51.3 0.00735 3000 1064 94878 21120 Supply Fan Outlet 54.4 0.00735 3000 1064 9996 - Cold Supply Duct Outlet 55.0 0.00735 2940 1064 - - Zone Air - 77.1 0.00840 2940 1344 68868 14420 Return Plenum Outlet 79.5 0.00840 2940 1344 7668 - Duct Leakage Air Outlet 54.4 0.00735 60 1064 - - Retum Duct Outlet 79.0 0.00838 3000 1338 - - Air Density x Heat Capacity x Conversion Factor: A sea level = 1.080; At site altitude = 1.063 BTU/(hr-CFM-F) Air Density x Heat of Vaporization x Conversion Factor: At sea level = 4746.6; At site altitude = 4670.1 BTU/(hr-CFM) Site Altitude = 449.0 ft TABLE 2: ZONE DATA Zone Name Zone Sensible Load (BTU/hr) T -stat Mode Zone Cond (BTU/hr) Zone Temp (°F) Zone Airflow (CFM) CO2 Level (ppm) Terminal Heating Coil (BTU/hr) Zone Heating Unit (BTU/hr) Zone 1 3254 Cooling 3623 76.0 167 1786 0 0 Zone 2 16389 Cooling 18588 76.6 810 1338 0 0 Zone 3 16282 Cooling 18885 77.3 796 1309 0 0 Zone 4 4994 Cooling 5793 77.3 244 1309 0 0 Zone 5 9873 Cooling 11451 77.3 483 1309 0 0 Zone 6 9077 Cooling 10528 77.3 444 1309 0 0 Hourly Analysis Program 5.11 Page 17 of 20 System Psychrometrics for VAV Project Name: TUK_SABEY_SEA CHILDRENS 1ST FL_v5_11 Prepared by: HERMANSON COMPANY LLP 09/06/2018 03:45PM WINTER DESIGN HEATING TABLE 1: SYSTEM DATA Component Location Dry -Bulb Temp (°F) Specific Humidity (Ib/Ib) Airflow (CFM) CO2 Level (ppm) Sensible Heat (BTUIhr) Latent Heat (BTU/hr) Ventilation Air Inlet 24.0 0.00103 876 400 -41776 0 Vent - Return Mixing Outlet 26.0 0.00103 917 400 - - Central Cooling Coil Outlet 26.0 0.00103 917 400 0 0 Supply Fan Outlet 27.4 0.00103 917 400 1334 - Cold Supply Duct Outlet 27.2 0.00103 898 400 - - Zone Air - 69.7 0.00103 898 401 -2776 0 Retum Plenum Outlet 69.7 0.00103 898 401 0 - Duct Leakage Air Outlet 27.4 0.00103 18 400 - - Retum Duct Outlet 68.9 0.00103 917 401 - - Air Density x Heat Capacity x Conversion Factor. A sea level = 1.080; At site altitude = 1.063 BTU/(hr-CFM-F) Air Density x Heat of Vaporization x Conversion Factor: At sea level = 4746.6; At site altitude = 4670.1 BTU/(hr-CFM) Site Altitude = 449.0 ft TABLE 2: ZONE DATA Zone Name Zone Sensible Load (BTU/hr) T -stat Mode Zone Cond (BTU/hr) Zone Temp (°F) Zone Airflow (CFM) CO2 Level (ppm) Terminal Heating Coil (BTU/hr) Zone Heating Unit (BTU/hr) Zone 1 -1745 Heating -1486 66.5 167 401 3804 0 Zone 2 -3019 Heating -1321 66.8 810 401 9411 0 Zone 3 0 Heatin 12 71.3 796 401 11769 0 Zone 4 0 Heating 4 71.3 244 401 3610 0 Zone 5 0 Heating 8 71.3 483 401 7136 0 Zone 6 0 Heating 7 71.3 444 401 6561 0 Hourly Analysis Program 5.11 Page 18 of 20 9 weJ6oad spAleuy AIJnoH 0 0 0 0 b 0 0 0 o N 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (3) 03 0 N - 0) 03 0 ( cum ) ipiwnH oijioeds r � o C :(7f CD o • co CD mcu • cn n � O Z C° � o 13-a ,O m v nZ v • a� CD m -1 EI D0, ZD w z-< 010, �D Dn Z= �O -u m z m r- < I01 System Psychrometrics for VAV 6.g we.I6ad sis (Ieuy AIJn0H OZ JO OZ a6ed 0 0 0 0 0 0 0 O N P O o 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 d7 0o O N - O Oo o ql/ql ) Alp w n H °woods D or 53- C N O N O Co— CO CD 2 0 co � D Cn m G) v z cn 5. m cQ D O z 0 System Psychrometrics for VAV =PERMIT COORD COPY 0 PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M18-0117 PROJECT NAME: SEATTLE CHILDRENS SITE ADDRESS: 3355 Sinn' PL X Original Plan Submittal Response to Correction Letter # DATE: 09/19/18 Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: \\g Building Division Public Works frIvI Fire Prevention Structural 6\110 Planning Division Permit Coordinator PRELIMINARY REVIEW: DATE: 0_9[210 8 Not Applicable ri Structural Review Required (no approval/review required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved DUE DATE: 10/18/18 ❑ Approved with Conditions ❑ Corrections Required ❑ Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire 0 Ping 0 PW ❑ Staff Initials: 12/18/2013 HERMANSON COMPANY LLP Washington State Department of Labor & Industries Flon]e Espanol Contact Safety & Health Claims & Insurance Search L&I 1: Page 1 of 3 A-Zindex 1 tele My T.&t Workplace Rights Trades & Licensing HERMANSON COMPANY LLP Owner or tradesperson Principals NICOLAISEN, KNUT H, PARTNER/MEMBER BROCK, DANIEL L, PARTNER/MEMBER FOX, DEAN M, PARTNER/MEMBER HENGEL, STEPHEN A, PARTNER/MEMBER DYCKMAN, KENNETH A, PARTNER/MEMBER ROBINETT, PAUL J, PARTNER/MEMBER HERMANSON, RICHARD L, PARTNER/MEMBER ALMON, KEVIN, PARTNER/MEMBER (End: 08/05/2010) MACDONALD, JAMES, PARTNER/MEMBER (End: 08/05/2010) Doing business as HERMANSON COMPANY LLP WA UBI No. 602 004 844 1221 2ND AVE N KENT, WA 98032-2945 206-575-9700 KING County Business type Limited Liability Partnership Governing persons CORP HERMANSON LLC HERMANSON GROUP; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. HERMACLOO5BJ Effective — expiration 01/11/2000— 08/25/2020 Bond WESTERN SURETY CO Bond account no. 929381801 Active. Meets current requirements. $12,000.00 Received by L&I Effective date 12/01/2005 01/01/2006 Expiration date Until Canceled Help us improve httns_//secure.lni.wa.aov/verify/Detail.aspx?UBI=602004844&LIC=HERMACL005BJ&SAW= 10/3/2018 HERMANSON COMPANY LLP Insurance Transportation Ins Co Policy no. 6043050846 $1,000,000.00 Received by L&I Effective date 08/16/2018 08/21/2018 Expiration date 08/21/2019 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violation No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID 409,648-01 Doing business as HERMANSON COMPANY LLP Estimated workers reported Quarter 2 of Year 2018 "Greater than 100 Workers" L&I account contact T4 / TERRI MADISON (360)902-4654 - Email: KIRT235@lni.wa.gov Account is current. Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 05/22/2018 Inspection no. 317948819 Location 1221 2nd Ave N Kent, WA 98032 Inspection results date 03/05/2018 Inspection no. 317948149 Location 635 Park Ave N Renton, WA 98057 Inspection results date 02/23/2016 Inspection no. 317939295 Violations No violations No violations Page 2 of 3 Help us improve https://secure.lni. ;va.gov/verify/Detail.aspx?UBI=602004844&LIC=HERMACL005BJ&SAW= 10/3/2018