Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M18-0120 - BOEING EMPLOYEES CREDIT UNION / GTATEWAY 7 - 1ST AND 2ND FLOOR OFFICE IMPROVEMENTS
BECU GATEWAY 7 12720 GATEWAY DR BLDG 7 M18-0120 Parcel No: Address: City of Tukwila Deportment of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 2716000070 Permit Number: M18-0120 12720 GATEWAY DR BLDG 7 Project Name: BECU GTATEWAY 7 Issue Date: 10/2/2018 Permit Expires On: 3/31/2019 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: BOEING EMPLOYEES' CREDIT UN 12770 GATEWAY DR , TUKWILA, WA, 98168 AMMONE BEMBRY Phone: (206) 768-4062 7717 DETROIT AVE SW , SEATTLE, WA, 98106 MACDONALD/MILLER FAC SOL INC Phone: (206) 768-4180 PO BOX 47983 , SEATTLE, WA, 98146- 7983 MACDOFS980RU Expiration Date: 1/4/2019 DESCRIPTION OF WORK: FULL 1ST AND 2ND FLOOR OFFICE TI IN WEST WING OF GATEWAY BLDG 7 TO CONVERT CLASSROOM LAYOUT INTO NEW OFFICE. CONVERT EXISTING VVT SYSTEM INTO A MORE EFFICIENT VAV SYSTEM WITH NEW BMS CONTROLS. REPLACE (24) EXISTING VVT ZONE DAMPERS WITH SERIES FAN POWERED VAV'S WITH ELECTRIC HEAT. MODIFY SUPPLY DISTRIBUTION SYSTEM TO ACCOMMODATE NEW OFFICE LAYOUT. Valuation of Work: $96,026.00 Type of Work: REPLACEMENT Fuel type: Fees Collected: $1,414.30 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 r.)(115114 re:� �� Authorized Si Permit Centernatu �' /�" g Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to t conditions attached to this permit. g Si nature: °")‘k -"" ""k L\t\V,lA Date: tb Print Name: �Y UXkt --Pa`hi6.1 l This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 4: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 8: ***MECHANICAL PERMIT CONDITIONS*** 9: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 10: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL CITY OF TIIKWI Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. I �+ 1 ' 011/0 Project No. Date Application Accepted: Date Application Expires: (For office use onl MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address: Tenant Name: King Co Assessor's Tax No.: 2716000070 12720 GATEWAY DR, TUKWILA, WA 981 BECU GATEWAY 7 Suite Number: PROPERTY OWNER Name: AMMONE BEMBRY Name: BECU City: SEATTLE State: WA Zip: 98106 Address: 12720 GATEWAY DRIVE Email: permits@macmiller.com City: TUKWILA State: WA Zip: 98168 CONTACT PERSON — person receiving all project communication Name: AMMONE BEMBRY Address: 7717 DETROIT AVE SW City: SEATTLE State: WA Zip: 98106 Phone: (206) 768-4062 Fax: Email: permits@macmiller.com New Tenant: Floor: 1 & 2 ❑ Yes ®.. No MECHANICAL CONTRACTOR INFORMATION Company Name: MACDONALD MILLER Address: 7717 DETROIT AVE SW Cin': SEATTLE State: WA Zip: 98106 Phone: (206) 768-4062 Fax: Contr Reg No.:MACDOFS980RU Exp Date: 01/03/2019 Tukwila Business License No.: BUS -0994318 Valuation of project (contractor's bid price): $ 96,026 Describe the scope of work in detail: Full 1st & 2nd floor office TI in west wing of Gateway Bldg 7 to convert classroom layout into new office. Convert existing VVT system into a more efficient VAV system with new BMS controls. Replace (24) existing VVT zone dampers with series fan powered VAV's with electric heat. Modify supply distribution system to accommodate new office layout. Use: Residential: New ❑ Replacement ......... ❑ Commercial: New ❑ Replacement 0 Fuel Type: Electric ❑ Gas ❑ Other: 14: Applications Forms -Applications On Line 2016 Applications'Mechanical Permit Application Revised I-4-16.docx Revised: January 2016 bh Page 1 of 2 J Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Residential, Nighttime Furnace >100k btu 86 Floor furnace 55 dB(A) Suspended/wall/floor mounted heater 57 dB(A) Appliance vent Commercial Repair or addition to heat/refrig/cooling system 24 Air handling unit 65 dB(A) <10,000 cfm 60 dB(A) Unit Type Qty Air handling unit Residential, Nighttime >10,000 cfm 86 Evaporator cooler 55 dB(A) Ventilation fan connected to single duct 57 dB(A) Ventilation system Commercial Hood and duct 24 Incinerator — domestic 65 dB(A) Incinerator — comm/industrial 60 dB(A) Unit Type Qty Fire damper Residential, Nighttime Diffuser 86 Thermostat 55 dB(A) Wood/gas stove 57 dB(A) Emergency generator Commercial Other mechanical equipment VAV BOXES 24 60 dB(A) 65 dB(A) Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-1 OPM, Monday through Friday and 8AM-1 OPM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: Warning devices; • Construction and property maintenance during the daytime hours (7am-10pm); • Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature:_ Date: 09/17/2018 Print Name: AMMONE BEMBRY Day Telephone: (206) 768-4062 Mailing Address: 7717 DETROIT AVE SW SEATTLE WA 98106 City State Zip H: Applications Forms -Applications On Line2016 Applications Mechanical Permit Application Revised 1-4.16.docx Revised: January 2016 bh Page 2 of 2 , si Register Receij City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $1,414.30 M18-0120 Address: 12720 GATEWAY DR BLDG 7 Apn: 2716000070 $1,414.30 MECHANICAL $1,359.90 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $1,054.77 PLAN CHECK FEE R000.322.102.00.00 0.00 $271.98 TECHNOLOGY FEE $54.40 TECHNOLOGY FEE TOTAL FEES' PAID BY RECEIPT: R15427 R000.322.900.04.00 0.00 $54.40 $1,414.30 Date Paid: Wednesday, September 19, 2018 Paid By: MACDONALD-MILLER Pay Method: CHECK 4857 Printed: Wednesday, September 19, 2018 12:09 1 of 1 PM SYSTEMS INSPECTION RECORD Retain a copy with permit M I$ 0120 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project --Type LL of Inspection: Address: 12.1 '4f Or Date Called: Special Instructions: • , g��'.1 Date Wanted: 'z.-. p. . Requester) Al� Phone No:©/1 70 loS7f39 / pproved per applicable codes. Corrections required prior to approval. MMENTS: 4,41„. Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit Ili /8 azo PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: fr7Priti -7 Type of Inspection: eiWale-r" /,&d i Address: /17Zo 4I.47,i,2644 Date Called: 7 Special Instructions: - Date Wanted: /FM -20/8 G.. p.m. Requester: AV Phone No: yam• r7f 3959 Approved per applicable codes. Corrections required prior to approval. COMMENTS: »oF�I 1/4"l f, �� Inspector: ,e 6?( REINSPECTION FEE REQUIRED. Prior to next inspection. ee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. CINSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 /r%/g a2.0 Project: 85e-t)4Ay -7 Type of Inspection: Pi,��/�� ' Address: /V) w G 3dt% bg_ Date Called: Special Instructions: 7 Date Wanted: u S � Gp.m. p Requester: Phone No: EApproved per applicable codes. Corrections required prior to approval. COMMENTS: gVo' Inspector: Date:H 2/40/6--' REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 /1(18 -0/m Project: /ST),Del A2 Type of Inspection: lint /e)() .t tG 4 Address: /27271 i4 -7X PR Date Called: G{<' 4L_ bCCT /Nrv-Pri 6A/ Special Instructions:Date � PlAtrpth /NSOAA-TJOAY % Wanted: //-/le l9 �a.m pair Requester: Phone No: 204 sz/ 390 EiApproved per applicable codes. Corrections required prior to approval. COMMENTS: /ST),Del A2 *kV /Da v,JsiT7o,J ,DSPs t!1SUcA-7 lint /e)() .t tG 4 4-te561,0 cvicK cbw5i7 crON pg_s-k 5 y 4V5571K-- //7 z) i7o,✓ .d A' ®,r' Sok DUCT G{<' 4L_ bCCT /Nrv-Pri 6A/ Inspector: Date// ,� REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 ntielonzo Project: gL'V 1/7 Type of Inspection: /'jt,eCht' oberiN i7 FC,4L Address: /27.20 407149 PR' Date Called: Special Instructions: Date Wanted: <a) Requester: Phone No: Approved per applicable codes. EJ Corrections required prior to approval. COMMENTS: Inspector: Date: /O—/44' REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION N0. PERMIT NO. CITY OF TUKWILA BUILDING DIVISIION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 11118-o t za Project: 84 -ea Gh1IEI41ny 7 Type of In pection: Pi AIkr /l5L)t 77 w Address: iZT20 47X )$-1 P2. Date Called: Special Instructions: . 7 Date Wanted:' `tp—`e) (4 Requester: Phone No: EApproved per applicable codes. Corrections required prior to approval. COMMENTS: ph 4/- 7i- R GyVi-y OK- f .c O46>1 /fi ok ,lis0t-f177E. Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. CZ)MacDonald -Miller FACILITY SOLUTIONS PRELIMINARY TEST, ADJUST & BALANCE REPORT FOR BECU - GATEWAY 7 73186683 12720 GATEWAY DRIVE TUKWILA, WA 98168 ENGINEER: HV ENGINEERING PROJECT MANGER: STEVE FLINK THE DATA PRESENTED IN THIS REPORT IS A RECORD OF SYSTEM MEASUREMENTS AND FINAL ADJUSTMENTSTHAT HAVE BEEN OBTAINED IN ACCORDANCE WITH THE CURRENT EDITION OF THE NEBB PROCEDURAL STANDARDS FOR TESTING, ADJUSTING, AND BALANCING OF ENVIRONMENTAL SYSTEMS. ANY VARIANCES FROM DESIGN QUANTITIES, WHICH EXCEED NEBB TOLERANCES, ARE NOTED IN THE TEST -ADJUST- BALANCE REPORT PROJECT SUMMARY. REPORT DATE: 12-27-18 FIELD FOREMAN: NATHAN EASTON MACDONALD-MILLER FACILITY SOLUTIONS MECHANICAL SERVICES #2661 7717 DETROIT AVENUE SW SEATTLE, WASHINGTON 98106 PHONE: (206) 763-9400 FAX: (206) 767-6773 <la) MacDonald-Miller FACILITY SOLUTIONS ABBREVIATIONS AC BDD BHP B.S. CEG CRG CFM CHWR CHWS CSD CWR CWS DD DP DIFF DMPR DNA DNL DNT DWDI EAT (DB) EAT (WB) EC EF EG ESP EWT FPM FH GPM HF AIR CONDITIONING UNIT BACK DRAFT DAMPER BRAKE HORSEPOWER BIRD SCREEN CEILING EXHUAST GRILLE CEILING RETURN GRILLE CUBIC FEET PER MINUTE CHILLED WATER RETURN CHILLED WATER SUPPLY CEILING SUPPLY DIFFUSER CONDENSER WATER RETURN CONDENSER WATER SUPPLY DIRECT DRIVE DIFFERENTIAL PRESSURE DIFFUSER DAMPER DATA NOT AVAILABLE DATA NOT LISTED DATA NOT TAKEN DOUBLE WIDTH DOUBLE INLET ENTERING AIR TEMP. (DRY BULB) ENTERING AIR TEMP. (WET BULB) EGGCRATE RETURN EXHAUST FAN EXHAUST GRILLE EXTERNAL STATIC PRESSURE ENTERING WATER TEMPERATURE FEET PER MINUTE FUME HooD GALLONS PER MINUTE HEPA FILTER HP HP HWR HWS INAC LAT (DB) LAT (WB) LD LWT MAX MIN 0 OBD OD OSA RA REQ'D RH RTU SA SP SWG SWR SWSI T TSP T.P. T -STAT TYP 0 V.D. HORSEPOWER HEAT PUMP AIR CONDITIONING UNIT HEATING WATER RETURN HEATING WATER SUPPLY INACCESSIBLE LEAVING AIR TEMP. (DRY BULB) LEAVING AIR TEMP. (WET BULB) LINEAR DIFFUSER LEAVING WATER TEMPERATURE MAXIMUM MINIMUM WIDE OPEN DAMPER / AIR PATH OPPOSED BLADE DAMPER OUTSIDE DIAMETER OUTSIDE AIR RETURN AIR REQUIRED RELATIVE HUMIDITY ROOFTOP UNIT SUPPLY AIR STATIC PRESSURE SIDE WALL GRILLE SIDE WALL REGISTER SINGLE WIDTH SINGLE INLET OUTLET NEAREST THERMOSTAT TOTAL STATIC PRESSURE THERMALLY PROTECTED THERMOSTAT OR SENSOR TYPICAL VOLTAGE PHASE / DUCT DIAMETER VOLUME DAMPER C:ilo MacDonald-Miller FACILITY SOLUTIONS Calibrations JOB NAME JOB # 1234-5678 Function Minimum Range Minimum Accuracy Minimum Resolution Instrument Model# / Serial# Calibration Date Rotational Measurement Tachometer 0 to 5000 RPM ±2% of reading ±2 RPM 1 RPM Extech - 461995 Z363139 06/19/18 Temperature Measurement Thermometer -40 to 240°F ±5% of reading + 1.4°F 0 2°F Thermometer Fluke - 52 Series II 26090483WS 11/15/18 Air Probe Probe Fluke - 80PK-5A Unknown/MAC-63690 11/15/18 Immersion Probe Probe Omega - 794 Unknown/26090483WS-B 11/15/18 Contact Probe Probe Omega - 792 Unknown/26090483WS-C 11/15/18 Electrical Measurement Volts 0 to 600 VAC ± 2% of reading ± 5 digits 1.0 Volts Fluke - 374 40010602WS 11/12/18 Amperes 0 to 100 Amps ± 2% of reading ± 5 digits 0.1 Ampere Fluke - 374 40010602WS 11/12/18 Air Pressure Air Pressure 0 to 10.00 in w.g. ±2% of reading ±0.001 in w.g. ±0.001 in w.g. <_ 1 in w.g. Shortridge ADM -880 M05779 11/28/18 Air Velocity Pitot Tube 50 to 3900 FPM ±5% of reading not Tess than 7 1.0 FPM Shortridge ADM -880 M05779 11/28/18 Air Velocity RVA 50 to 2500 FPM ±2% of reading ± 4 FPM 1.0 FPM TSI / Alnor - RVA501 RVA501804001 11/15/18 Humidity 10 to 90% RH ± 3% RH 1.00% TSI - 966 P08410045 06/25/18 Hydronic Measurement Hydronic Yg Differential 0 to 200 in w.g. ± 2% of reading ±0.2 ft w.g. 1.0 ft w.g. TSI/Alnor - HM675 71705053 06/25/18 12/6/2018 42Z> MacDonald -Miller FACILITY SOLUTIONS Project Job Number BECU Gateway 7 73186683 Area Served VAV-111 System Air Outlet Test Report First Floor Outlet Design Preliminary Final Percent of Design No. 1 Type 1 Size 1 Ak Vel. 1 Flow Vel. 1 Flow Vel. 1 Flow IT/0 1 CD 8 1 285 145 10 210 140 97% 340 2 CD 8 1 0 145 CD 215 1 145 100% Address Inlet Size Multiplier Totals 111 6 0.68 Remarks: Fan set at 5.0 VDC 290 Max Flow Min Flow Fan Total 425 Design 285 98% Actual 285 270 215 210 290 285 Test Date: 12/12/2018 Readings By: CW VAV-112 J 405 410 1010 1 CD 10 1 150 340 145 97% 0 2 CD 12 1 215 265 220 102% 3 CD 12 1 215 265 225 105% T 4 CD 12 1 215 265 230 107% 0 5 CD 10 1 215 255 230 107% Address Inlet Size Multiplier Totals 112 12 0.69 Remarks: Fan set at 5.0 VDC 1010 Max Flow Min Flow Fan Total 1390 Design 1050 104% Actual 1010 1050 405 410 1010 1050 Test Date: 12/12/2018 Readings By: CW VAV-113 990 690 655 T 1 CD 12 1 325 415 300 92% 0 2 CD 12 1 325 465 335 103% 3 CD 12 1 325 455 330 102% Address Inlet Size Multiplier Totals 113 12 0.69 Remarks: Fan set at 3.0 VDC Test Date Readings By 975 Max Flow Min Flow Fan Total 1335 Design 965 99% Actual 1000 990 690 655 975 965 Test Date: 12/12/2018 Readings By: CW Page: C6=0 MacDonald -Miller FACILITY S©WT1ONS Project Job Number BECU Gateway 7 73186683 Area Served System Air Outlet Test Report Outlet Design Preliminary Final Percent of Design No. l Type 1 Size 1 Ak Vel. 1 Flow Vel. 1 Flow Vel. 1 Flow VAV-105 1 505 500 1190 1 CD 12 1 570 400 380 360 425 106% CD 12 2 CD 12 1 630 400 400 365 430 108% CD TIO 3 CD 12 1 370 390 245 315 420 108% Address Inlet Size Multiplier Totals 50 12 0.67 AT: Remarks: Fan set at 5.5 VDC VAV-104 1190 Max Flow Min Flow Fan Total 1040 Design 1275 107% Actual 1190 1185 505 500 1190 1275 Test Date: 12/18/2018 Readings By: DF/MM Address Inlet Size Multiplier Totals 49 12 0.75 AT: 15 Remarks: Fan set at 2.8 VDC 1040 Max Flow Min Flow Fan Total 1570 Design 1025 99% Actual 1040 . 1 CD 12 1 400 570 380 95% O 2 CD 12 1 400 630 400 100% T 3 CD 10 1 240 370 245 102% Address Inlet Size Multiplier Totals 49 12 0.75 AT: 15 Remarks: Fan set at 2.8 VDC 1040 Max Flow Min Flow Fan Total 1570 Design 1025 99% Actual 1040 1070 560 560 1040 1025 Test Date: 12/18/2018 Readings By: DF/MM (4:210 MacDonald -Miller FACILITY SOLUTIONS Project Job Number BECU Gateway 7 73186683 Area Served System Air Outlet Test Report Outlet Design Preliminary Final Percent of Design No. 1 Type 1 Size 1 Ak Vel. 1 Flow Vel. l Flow Vel. 1 Flow VAV-107 J 560 569 1000 1 CD 12 1 400 475 305 102% 2 CD 12 1 400 470 290 97% T 3 CD 10 1 275 275 120 96% 4 CD 12 1 400 _ 300 115 92% Address Inlet Size Multiplier Totals 14 AT: 1475 Max Flow Min Flow Fan Total Remarks: Controller not controlling, Controls tech is troubleshooting Design Actual 1475 730 1475 Test Date: Readings By: VAV-103 1 560 569 1000 1 CD 12 1 300 475 305 102% 2 CD 12 1 300 470 290 97% T 3 CD 10 1 125 275 120 96% 4 CD 10 1 125 300 115 92% 0 5 CD 10 1 150 195 145 97% Address Inlet Size Multiplier Totals 48 12 0.602 AT: 20 Remarks: Fan set at 1.8 VDC 1000 Max Flow Min Flow Fan Total 1715 Design 975 98% Actual 1000 986 560 569 1000 975 Test Date: 12/20/2018 Readings By: NE/LH 4rZlno MacDonald-Miller FACILITY SOLUTIONS Project Job Number BECU Gateway 7 73186683 Area Served System Air Outlet Test Report Outlet Design Preliminary Final Percent of Design No. Type Size 1 Ak Vel. 1 Flow Vel. 1 Row Vel. 1 Flow VAV-200 1 360 350 0 1 CD 8 1 170 170 165 97% CD 10 2 CD 8 1 175 205 170 97% CD 8 3 CD 8 1 100 195 95 95% CD T 4 CD 8 1 100 195 105 105% Totals 545 765 535 98% Address Inlet Size Multiplier 59 10 0.66 AT: 22 Remarks: Fan set at 4.5 VDC Max Flow Min Flow Fan Total Design Actual 545 532 360 350 545 535 Test Date: 12/20/2018 Readings By: NE/LH VAV-201 849 390 385 840 1 CD 10 1 300 285 300 100% CD 10 2 CD 10 1 300 310 315 105% CD 8 3 CD 8 1 120 165 115 96% CD 8 4 CD 8 1 120 140 120 100% Address Inlet Size Totals 60 10 Multiplier 0.567 Remarks: Fan set at 6.4 VDC VAV-202 AT: 20 840 Max Flow Min Flow Fan Total 900 Design 850 Actual 840 849 390 385 840 850 Test Date: 12/20/2018 Readings By: NE/LH Address Inlet Size Totals 0 Design Actual Max Flow I 1 CD 10 1 2 CD 10 1 3 CD 8 1 4 CD 8 1 Address Inlet Size Totals 0 Design Actual Max Flow I Multiplier Remarks: AT: Min Flow Fan Total Test Date: Readings By: Outlet Design Preliminary Final Percent of Design No. 1 Type 1 Size 1 Ak Vel. 1 Flow Vel. 1 Flow Vel. 1 Flow VAV-203 910 489 498 0 1 CD 10 1 450 300 380 280 300 100% CD 12 2 CD 10 1 355 300 385 315 305 102% CD T 3 CD 8 1 165 155 230 185 150 97% 4 CD 8 1 155 175 155 100% Address Inlet Size Multiplier Totals 12 0.68 AT: 18.5 Remarks: Fan set at 1.7 VDC VAV-205 910 Max Flow Min Flow Fan Total 955 Design 910 100% Actual 910 910 489 498 910 910 Test Date: 12/21/2018 Readings By: LH Address Inlet Size Multiplier Totals 64 12 0.61 AT: 17 Remarks: Fan set at 2.5 VDC 1025 Max Flow Min Flow Fan Total 970 Design 995 97% Actual 1025 1004 1 CD 12 1 CD 400 1 450 350 380 95% 345 2 CD 12 1 CD 400 1 355 350 385 96% T/0 3 CD 10 1 CD 225 1 165 140 230 102% Address Inlet Size Multiplier Totals 64 12 0.61 AT: 17 Remarks: Fan set at 2.5 VDC 1025 Max Flow Min Flow Fan Total 970 Design 995 97% Actual 1025 1004 575 569 1025 995 Test Date: 12/27/2018 Readings By: NE/LH VAV-204 967 575 553 980 1 CD 12 1 350 710 345 99% 0 2 CD 12 1 350 470 335 96% T 3 CD 10 1 140 265 140 100% 4 CD 10 1 140 215 135 96% Address Inlet Size Multiplier Totals 63 12 0.613 AT: 19 Remarks: Fan set at 2.0 VDC 980 Max Flow Min Flow Fan Total 1660 Design 955 97% Actual 980 967 575 553 980 955 Test Date: 12/27/2018 Readings By: NE/LH 0=30 MacDonald -Miller FACILITY SOWT1ONS Project Job Number BECU Gateway 7 73186683 Area Served VAV-206 System Air Outlet Test Report Outlet Design Preliminary Final Percent of Design No. 1 Type 1 Size 1 Ak Vel. 1 Flow Vel. 1 Flow Vel. 1 Flow Address Inlet Size Multiplier Totals 65 12 0.62 AT: 16 Remarks: Fan set at 4.5 VDC VVT-229 1145 Max Flow Min Flow Fan Total 1190 Desi4n 1120 98% Actual 1145 1154 1 CD 12 1 400 515 400 100% T 2 CD 12 1 400 350 390 98% 0 3 CD 12 1 345 325 330 96% Address Inlet Size Multiplier Totals 65 12 0.62 AT: 16 Remarks: Fan set at 4.5 VDC VVT-229 1145 Max Flow Min Flow Fan Total 1190 Desi4n 1120 98% Actual 1145 1154 550 569 1145 1120 Test Date: 12/27/2018 Readings By: NE/LH . T/O 1 CD 10 1 300 320 305 102% 2 CD 10 1 300 315 300 100% Address Inlet Size Multiplier Totals 75 14 0.69 600 Max Flow Min Flow 635 Design 605 101% Actual 600 605 400 410 Remarks: Design maximum primary is 800 while the outlets are designed Test Date: 12/27/2018 for 600. Readings By: NE/LH INT -230 Address Inlet Size Multiplier Totals 76 16 0.75 600 Max Flow Min Flow 580 Design 580 97% Actual 600 580 300 280 Remarks: Design maximum primary is 1220 while the outlets are designed Test Date: 12/27/2018 for 600. Minimum CFM designed for 630. Lowered to 300 until further Readings By: NE/LH Page: j 1 CD 10 1 300 285 285 95% 2 CD 10 1 300 295 295 98% Address Inlet Size Multiplier Totals 76 16 0.75 600 Max Flow Min Flow 580 Design 580 97% Actual 600 580 300 280 Remarks: Design maximum primary is 1220 while the outlets are designed Test Date: 12/27/2018 for 600. Minimum CFM designed for 630. Lowered to 300 until further Readings By: NE/LH Page: IZZ)MacDonald-Miller FACILITY SOWTIONS Project Job Number BECU Gateway 7 73186683 Area Served System Air Outlet Test Report Outlet Design Preliminary Final Percent of Design No. 1 Type 1 Size 1 Ak Vel. 1 Flow Vel. 1 Flow Vel. 1 Flow VVT-231 1 415 402 985 1 CD 10 1 300 225 270 90% 2 CD 10 1 300 225 325 108% 3 CD 10 1 300 210 285 95% 4 CD 10 1 300 235 300 100% Totals 1200 895 1180 98% Address Inlet Size Multiplier 77 16 0.801 Max Flow Min Flow Design Actual 1200 1180 630 650 1200 1180 Remarks: Design maximum primary is 2000 while the outlets are designed Test Date: 12/27/2018 for 1200. Readings By: NE/LH VAV-207 967 415 402 985 1 CD 10 1 340 395 335 99% 2 CD 10 1 345 385 330 96% 3 CD 8 1 150 395 145 _ 97% 4 CD 8 1 150 430 145 97% Address Inlet Size Multiplier Totals 66 12 0.62 AT: 12 Remarks: Fan set at 2.8 VDC 985 Max Flow Min Flow Fan Total 1605 Design 955 97% Actual 985 967 415 402 985 955 Test Date: 12/27/2018 Readings By: NE/LH CZ>MacDonald-Miller FACILITY SOLUTIONS Project Job Number BECU Gateway 7 73186683 Area Served System Air Outlet Test Report Outlet Design Preliminary Final Percent of Design No. 1 Type 1 Size 1 Ak Vel. 1 Flow Vel. 1 Flow Vel. 1 Flow VAV-208 849 480 465 850 1 CD 10 1 300 200 305 175 310 200 100% 2 2 CD 10 1 300 225 410 85 310 230 102% 3 3 CD 10 1 200 200 335 150 200 190 95% 4 4 CD 10 1 200 225 325 120 210 230 102% Address Inlet Size Multiplier Totals 67 12 0.62 AT: 18 Remarks: Fan set at 7.3 VDC 850 Max Flow Min Flow Fan Total 530 Design 850 100% Actual 850 849 480 465 850 850 Test Date: 12/27/2018 Readings By: NE/LH VAV-209 1 740 754 1 CD 10 1 300 305 310 103% 2 CD 10 1 300 410 310 103% 3 CD 10 1 200 335 200 100% 4 CD 10 1 200 325 210 105% 5 CD 8 1 150 190 150 100% 6 CD 8 1 150 165 155 103% Address Inlet Size Multiplier Totals 73 12 0.62 AT: 17 Remarks: Fan set at 5.0 VDC 1300 Max Flow Min Flow Fan Total 1730 Design 1335 103% Actual 1300 1280 740 754 1300 1335 Test Date: 12/27/2018 Readings By: NE/LH Page: Project Information FIGURE 14B COMMISSIONING COMPLIANCE CHECKLIST Commissioning Authority: Commissioning Plan (Section 1416.3.1) Systems Balancing (Section 1416.3.2) Functional Testing (Section 1416.3.3) 19- Commissioning Plan was used during construction and included items below • A written schedule including Systems Testing and Balancing, Functional Testing, and Supporting Documentation • Roles and Responsibilities of the commissioning team • Functional Test procedures and forms tig. Systems Balancing has been completed • Air and Hydronic systems are proportionately balanced in a manner to first minimize throttling losses • Test ports are provided on each pump for measuring pressure across the pump. • HVAC Systems Functional Testing has been completed (Section 1416.3.3) HVAC systems have been tested to ensure that equipment, components, and sub -systems are installed, calibrated, adjusted and operate in accordance with approved plans and specifications HVAC Controls Functional Testing has been completed (Section 1416.3.3) HVAC controls have been tested to ensure that control devices are calibrated, adjusted and operate properly. Sequences of operation have been functionally tested to ensure they operate in accordance with approved plans and specifications ❑ Lighting Controls Functional Testing has been completed (Section 1513.8) Lighting controls have been tested to ensure that control devices, components, equipment, and systems are calibrated, adjusted and operate in accordance with approved plans and specifications Supporting Documents (Section 1416.3.4) _ Systems documentation, record documents and training have been completed or are scheduled • System documentation has been provided to the owner or scheduled date: • Record documents have been submitted to owner or scheduled date: • Training has been completed or scheduled date: Commissioning Report (Section 1416.3.5) Certification ❑ Commissioning Report submitted to Owner and includes items below • Completed Functional Tests documentation • Deficiencies found during testing required by this section which have not been corrected at the time of report preparation and the anticipated date of correction • Deferred tests, which cannot be performed at the time of report preparation due to climatic conditions or other circumstances beyond control of Commissioning Authority. I hereby certify that all requirements for Commissioning have been completed in accordance with ttle Energy Code, including all items above. i J Building Owner or Owner's Representative Z1Z7 f e Date Seattle amendments do not apply to residential spaces, except that procedural requirements and informative notes in boxed text or brackets, and amendments to administrative and enforcement provisions, apply to all projects. 104 Effective November 23, 2010/January 1, 2011 �ERMI� COORS COPY 0 PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M18-0120 DATE: 09/20/18 PROJECT NAME: BECU GATEWAY 7 SITE ADDRESS: 12720 GATEWAY DR X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: PSN() 1Aj\46 Building Division Public Works ❑ ki\A 0\\* Fire Prevention IN Structural Planning Division ❑ Permit Coordinator PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 09/25/A Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved DUE DATE: 10/23/18 ❑ Approved with Conditions ❑ Corrections Required ❑ Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: 12/18/2013 MACDONALD/MILLER FAC SOS ANC Horne Espanol Contact Safety & Health Claims & Insurance Washington State Department of ki Labor & Industries Page 1 of 3 Search L&I A -Z Index Ile:p Aly I �:I Workplace Rights Trades & Licensing MACDONALD/MILLER FAC SOL INC Owner or tradesperson Principals SIMONDS, DERRICK R, PRESIDENT WEBSTER, MARK E, VICE PRESIDENT GEBHARDT, STEPHANIE WETTACH, TREASURER NOEL, STEPHANIE W, MEMBER SIGMUND, FREDRIC, PRESIDENT (End: 01/04/2011) LOVELY, STEVE C, VICE PRESIDENT (End: 01/04/2011) HACK, RICHARD, SECRETARY (End: 01/04/2011) KOPET, TYLER, TREASURER (End: 01/04/2011) TURLEY, DOUGLAS, CHIEF EXECUTIVE OFFJCER (End: 01/04/2011) TURLEY, DOUGLAS, CHIEF OPERATING OFFICER (End: 01/04/2011) GOUGH, DAVID ANTHONY, DIRECTOR (End: 08/29/2014) Doing business as MACDONALD/MILLER FAC SOL INC WA UBI No. 602 254 260 PO BOX 47983 SEATTLE, WA 98106 206-768-4180 KING County Business type Corporation Governing persons FREDRIC J SIGMUND STEVE C LOVELY; TYLER C KOPET; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. MACDOFS980RU Effective — expiration Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602254260&LIC=MACDOFS980RU&SAW= 10/2/2018 MACDONALD/MILLER FAC SOL INC 12/31/2002— 01/04/2019 Bond LIBERTY MUTUAL INS CO Bond account no. 023006951 $12,000.00 Received by L&I Effective date 12/31/2002 12/11/2002 Expiration date Until Canceled Insurance Phoenix Insurance Company, The $1,000,000.00 Policy no. DT-CO-3K790954-PHX-1 Received by L&I Effective date 01/02/2018 12/31/2017 Expiration date 12/31/2018 Liberty Mutual Ins Co Policy no. TB7-661-066178-033 $2,000,000.00 Received by L&I Effective date 11/20/2017 12/31/2013 Expiration date 12/31/2018 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. This company has multiple workers' comp accounts. Active accounts L&I Account ID 706,276-00 ................ Doing business as MACDONALD MILLER FACILITY Estimated workers reported N/A L&I account contact (360)902-4817 Track this contractor Self Insured. This business is certified to cover its own workers' comp costs. No premiums due. Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Page 2 of 3 Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602254260&LIC=MACDOFS980RU&SAW= 10/2/2018 MACDONALD/MILLER FAC SO/11 SNC Workplace safety and health._/ 7 A Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 07/10/2018 Under appeal. The results of the inspection are Inspection no. being challenged. 317949476 Date of appeal Location 07/13/2018 451 SW 10th ST Renton, WA 98057 Inspection results date 08/24/2015 Inspection no. 317936840 Location 14360 SE Eastgate Way Bellevue, WA 98007 Inspection results date 08/04/2015 Inspection no. 317937121 Location 530 Fairview Ave N Seattle, WA 98103 Violations No violations Page 3 of 3 Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington, Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602254260&LIC=MACDOFS980RU&SAW= 10/2/2018