HomeMy WebLinkAboutPermit M18-0121 - SEATTLE CHILDRENS - AIR DISTRIBUTIONSEATTLE CHILDREN'S 12101 TUKWILA INTL BLVD 300 M18-0121 Parcel No: Address: Project Name: 1 City of Tukwila Department of Community Development 6300 $outhcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 0923049309 Permit Number: M18-0121 12101 TUKWILA INTL BLVD 300 Issue Date: 10/3/2018 Permit Expires On: 4/1/2019 SEATTLE CHILDRENS Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: INTERNATIONAL GATEWAY WEST 12201 TUKWILA INTERNATIONAL BL, SEATTLE, WA, 98168 KAYLENE NELSON 1221 SECOND AVE N , KENT, WA, 98032 HERMANSON COMPANY LLP (GENERAL) 1221 2ND AVE N , KENT, WA, 98032- 2945 License No: HERMACLOO5BJ Lender: Name: Address: Phone: (253) 359-7147 Phone: (206) 575-9700 Expiration Date: 8/25/2020 DESCRIPTION OF WORK: MODIFY AIR DISTRIBUTION FOR 8 ZONES AS NEEDED TO ACCOMMODATE NEW LAYOUT. Valuation of Work: $18,000.00 Type of Work: REPLACEMENT Fuel type: ELECT Fees Collected: $450.48 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: 20 Sewer District: VALLEY VIEW Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Date: 10 - 3—i ej I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development pe it and agree to the conditions attached to this permit. Signature: Print Name: K i y(J- i )0 -as Date:L(041 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 4: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 8: ***MECHANICAL PERMIT CONDITIONS*** 9: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 10: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0701 ROUGH -IN MECHANICAL CITY OF TUKR, ,A Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov MECHANICAL Applications and plans must be Applications will not Mechanical Permit No. Project No. a'�1 I fi — c'/a / Date Application Accepted: Date Application Expires: or . zce use onl PERMIT APPLICATION complete in order to be accepted for plan review. be accepted through the mail or by fax. **please print** SITE LOCATION King Co Assessor's Tax No.: Site Address: 12101 Tukwila International BLVD Suite Number: 300 Floor: New Tenant: ❑ Yes ❑ „No 0923049309 Tenant Name: Seattle Childrens PROPERTY OWNER Name: WA & N Idaho District Council of Laborers Address: PO Box 12917 City: Mill Creek State: WA Zip: 98082 CONTACT PERSON — person receiving all project communication Name: Kaylene Nelson Address: 1221 2nd Avenue N City: Kent State: WA Zip: 98032 Phone: (253) 359-7147 Fax: Email: Kaylene.nelson@hermanson.com MECHANICAL CONTRACTOR INFORMATION Company Name: Hermanson Company Address: 1221 2nd Avenue N City: Kent State: WA Zip: 98032 Phone: (253) 359-7147 Fax: Contr Reg No.: NERMACL005BJ Exp Date: 08/25/2018 Tukwila Business License No.: BUS -0994464 Valuation of project (contractor's bid price): $ 18,000 Describe the scope of work in detail: Modify air distribution for 8 zones as needed to accommodate new layout Use: Residential: Commercial: New El New ❑ Replacement Replacement Fuel Type: Electric E Gas ❑ Other: H: Applications Forms -Applications On Line 2011 Applications Mechanical Permit Application Revised 8-9-1 I.docx Revised: August 2011 bh Page of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu 18 Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm 18 Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser 18 Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR t' TH i Z D A . T: Signature: Date: 09/11/2018 Print Name: Kaylene Nelson Day Telephone: (253) 359-7147 Mailing Address: 1221 2nd Avenue N H: Applications Forms -Applications On Line 2011 Applications Mechanical Permit Application Revised 8-9-1 I .docx Revised: August 201 I bh Kent WA 98032 City State Zip Page 2 of 2 / 1 DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $450.48 M18-0121 Address: 12101 TUKWILA INTL BLVD 300 Apn: 0923049309 $450.48 Credit Card Fee $13.12 Credit Card Fee R000.369.908.00.00 0.00 $13.12 MECHANICAL $420.54 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $303.28 PLAN CHECK FEE R000.322.102.00.00 0.00 $84.11 TECHNOLOGY FEE $16.82 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R15432 R000.322.900.04.00 0.00 $16.82 $450.48 Date Paid: Wednesday, September 19, 2018 Paid By: HERMANSON COMPANY LLP Pay Method: CREDIT CARD 448185 Printed: Wednesday, September 19, 2018 1:23 1 of 1 PM 1 /t I SYSTEMS r 1 CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA Date: 09/19/2018 01:22:39 PM CREDIT CARD SALE VISA CARD NUMBER: **********0057 K TRAN AMOUNT: $450.48 APPROVAL CD: 448185 RECORD #: 000 CLERK ID: Laurie Thank you! Customer Copy Page 2 of 2 https://classic. convergepay. com/V irtualMerchant/transaction. do?dispatchMethod=printTra... 9/19/2018 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 NI' 18-012 / Project: 570/9-77—L e /mi-DROIS Type of Inspection: Rom /H ,(CA 9{I Address: /2/0/ 77// 25 Date Called: _ Special Instructions: Date Wanted: //-Z a.m.; -45 p.m. Requester: Phone No: Aktpproved per applicable codes. LJ Corrections required prior to approval. COMMENTS: 8K-Igtz. , p —cz� ice - Ue I , 7451A" 1 vwc4.1-00 cfit Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Hermanson Building Today, Defining Tomorrow Hermanson Company LLP 1221 2nd Avenue North Kent, WA 98032 tel 206-575-9700 fax 206-575-9800 Project: 12101 Tukwila International Blvd, Tukwila Date: 09/05/2018 September 18, 2018 2018.09.18 10:49:30-07'00' Document approved, mechanical design pages %t REVIEWED FOR CODE COMPLIANCE APPROVED SEP 27 2018 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA SEP 1 9 2018 PERMIT CENTER HVAC SYSTEM COOLING/HEATING CALCS CARRIER HAP VERSION: 5.11 PERMIT SUBMITTAL PACKAGE Mrif 019-1 Mechanical Construction, Engineering and Service www.hermanson.com • Z. Hermanson Building Today, Defining Tomorrow Hermanson Company LLP 1221 2nd Avenue North Kent, WA 98032 te/ 206-575-9700 fax 206-575-9800 Project: 12101 Tukwila International Blvd, Tukwila Date: 09/05/2018 i� Hermanson Building Today, Defining Tomorrow HVAC SYSTEM COOLING/HEATING CALCS CARRIER HAP VERSION: 5.11 ENVELOPE INPUTS Mechanical Construction, Engineering and Service www.hermanson.com Wall Constructions TUK_SABEY_IGW-C_LEVEL 3RD FL -1_v5_11 HERMANSON COMPANY LLP 09/05/2018 10:29AM Existing Wall Wall Details Outside Surface Color Absorptivity Overall U -Value Wall Lavers Details (Inside to Outside Medium 0.675 0.114 BTU/(hrft2•°F) Layers Thickness in Density Ib/ft' Specific Ht. BTU / (Ib.°F) R -Value (hrft2•°F)/BTU Weight Ib/ft2 Inside surface resistance 0.000 0.0 0.00 0.68500 0.0 Gypsum board 0.625 50.0 0.26 0.56000 2.6 R-11 batt insulation 3.500 0.5 0.20 6.50000 0.1 8 -in HW concrete 8.000 140.0 0.20 0.66667 93.3 Outside surface resistance 0.000 0.0 0.00 0.33300 0.0 Totals 12.125 - 8.74467 96.1 Hourly Analysis Program v5.11 Page 1 of 1 Window Constructions 'rUK_SAB°EY_IGW-C_LEVEL 3RD FL -1_v5_11 HERMANSON COMPANY LLP 09/05/2018 10:30AM Existing Glazing Window Details: Detailed Input No Height 1.00 ft Width 1.00 ft Overall U -Value 0.560 BTU/(hr•ft2•°F) Overall Shade Coefficient 0.570 Hourly Analysis Program v5.11 Page 1 of 1 Hermanson L: Building Today. Defining Tomorrow Hermanson Company LLP 1221 2nd Avenue North Kent, WA 98032 tel 206-575-9700 fax 206-575-9800 Project: 12101 Tukwila International Blvd, Tukwila Date: 09/05/2018 Hermanson Building Today, Defining Tomorrow HVAC SYSTEM COOLING/HEATING CALCS CARRIER HAP VERSION: 5.11 SPACE INPUTS Mechanical Construction, Engineering and Service www.hermanson.com UK_SABIEY_IGW-C_LEVEL 3RD FL-1_v5_11 HERMANSON COMPANY LLP Space Input Data 09/05/2018 10:30AM 03-01 Office 1. General Details: Floor Area 285.0 ft2 Avg. Ceiling Height 9.0 ft Building Weight 70.0 Ib/ftZ 1.1. OA Ventilation Requirements: Space Usage User -Defined OA Requirement 1 5.0 CFM/person OA Requirement 2 0.06 CFM/ft2 Space Usage Defaults ASHRAE Std 62.1-2010 2. Internals: 2.1. Overhead Lighting: Fixture Type Wattage Ballast Multiplier Schedule 2.2. Task Lighting: Wattage Schedule 2.3. Electrical Equipment: Wattage Schedule 3. Walls, Windows, Doors: Recessed (Unvented) 0.89 W/ft2 1.08 90.1 Office Lights/Elec 0.00 W/ft2 None 145.0 Watts 90.1 Office Lights/Elec 2.4. People: Occupancy Activity Level Sensible Latent Schedule 2.5. Miscellaneous Loads: Sensible Schedule Latent .. Schedule Exp. Wall Gross Area (ft') Window 1 Qty. Window 2 Qty. Door 1 Qty. W 201.5 55 0 0 N 227.5 62 0 0 3.1. Cons ruction Types for Exposure W Wall Type 1st Window Type 3.2. Construction Types for Exposure N Wall Type 1st Window Type 4. Roofs, Skylights: (No Roof or Skylight data). 5. Infiltration: Design Cooling Design Heating Energy Analysis Infiltration occurs at all hours. Existing Wall Existing Glazing Existing Wall Existing Glazing 0.00 CFM 0.50 ACH 0.00 CFM 6. Floors: Type Floor Above Conditioned Space (No additional input required for this floor type). 7. Partitions: (No partition data). 3.0 People Office Work 245.0 BTU/hr/person 205.0 BTU/hr/person 90.1 Office Occupants 0 BTU/hr None 0 BTU/hr None Hourly Analysis Program v5.11 Page 1 of 13 TUK_SAEtY_IGW-C_LEVEL 3RD FL -1_v5_11 HERMANSON COMPANY LLP Space Input Data 09/05/2018 10:30AM 03-02 Office 1. General Details: Floor Area 283.0 ft2 Avg. Ceiling Height 9.0 ft Building Weight 70.0 Ib/ft2 1.1. OA Ventilation Requirements: Space Usage User -Defined OA Requirement 1 5.0 CFM/person OA Requirement 2 0.06 CFM/ft2 Space Usage Defaults ASHRAE Std 62.1-2010 2. Internals: 2.1. Overhead Lighting: 2.4. People: Fixture Type Recessed (Unvented) Occupancy 3.0 People Wattage 0.89 W/ft2 Activity Level Office Work Ballast Multiplier 1.08 Sensible 245.0 BTU/hr/person Schedule 90.1 Office Lights/Elec Latent 205.0 BTU/hr/person Schedule 90.1 Office Occupants 2.2. Task Lighting: Wattage Schedule 2.3. Electrical Equipment: Wattage Schedule 3. Walls, Windows, Doors: 2.5. Miscellaneous Loads: 0.00 W/ft2 Sensible 0 BTU/hr None Schedule None Latent 0 BTU/hr Schedule None 145.0 Watts 90.1 Office Lights/Elec Exp. Wall Gross Area (ft2) Window 1 Qty. Window 2 Qty. Door 1 Qty. N 227.5 88 0 0 3.1. Construction Types for Exposure N Wall Type 1st Window Type 4. Roofs, Skylights: (No Roof or Skylight data). 5. Infiltration: Design Cooling Design Heating Energy Analysis Infiltration occurs at all hours. Existing Wall Existing Glazing 0.00 CFM 0.50 ACH 0.00 CFM 6. Floors: Type Floor Above Conditioned Space (No additional input required for this floor type). 7. Partitions: (No partition data). Hourly Analysis Program v5.11 Page 2 of 13 rUK_SABEY_IGW-C_LEVEL 3RD FL -1_v5_11 HERMANSON COMPANY LLP Space Input Data 09/05/2018 10:30AM 03-03 Office 1. General Details: Floor Area 324.0 ft2 Avg. Ceiling Height 9.0 ft Building Weight 70.0 Ib/ftz 1.1. OA Ventilation Requirements: Space Usage User -Defined OA Requirement 1 5.0 CFM/person OA Requirement 2 0.06 CFM/ft2 Space Usage Defaults ASHRAE Std 62.1-2010 2. Internals: 2.1. Overhead Lighting: Fixture Type Wattage Ballast Multiplier Schedule 2.2. Task Lighting: Wattage Schedule 2.3. Electrical Equipment: Wattage Schedule 3. Walls, Windows, Doors: Recessed (Unvented) 0.89 W/ftz 1.08 90.1 Office Lights/Elec 0.00 W/ftz None 435.0 Watts 90.1 Office Lights/Elec 2.4. People: Occupancy Activity Level Sensible Latent Schedule 2.5. Miscellaneous Loads: Sensible Schedule Latent Schedule Exp. Wall Gross Area (ft') Window 1 Qty. Window 2 Qty. Door 1 Qty. N 253.5 75 0 0 E 201.5 75 0 0 3.1. Construction Types for Exposure N Wall Type 1st Window Type 3.2. Construction Types for Exposure E Wall Type 1st Window Type 4. Roofs, Skylights: (No Roof or Skylight data). 5. Infiltration: Design Cooling Design Heating Energy Analysis Infiltration occurs at all hours. Existing Wall Existing Glazing Existing Wall Existing Glazing 0.00 CFM 0.50 ACH 0.00 CFM 6. Floors: Type Floor Above Conditioned Space (No additional input required for this floor type). 7. Partitions: (No partition data). 7.0 People Office Work 245.0 BTU/hr/person 205.0 BTU/hr/person 90 ..1 Office Occupants 0 BTU/hr None 0 BTU/hr None Hourly Analysis Program v5.11 Page 3 of 13 TUK_SAB'EY_IGW-C_LEVEL 3RD FL -1_v5_11 HERMANSON COMPANY LLP Space Input Data 09/05/2018 10:30AM 03-04 Office 1. General Details: Floor Area Avg. Ceiling Height Building Weight 1.1. OA Ventilation Requirements: Space Usage User -Defined OA Requirement 1 5.0 CFM/person OA Requirement 2 0.06 CFM/ft2 Space Usage Defaults ASHRAE Std 62.1-2010 143.0 ft2 9.0 ft 70.0 Ib/ft2 2. Internals: 2.1. Overhead Lighting: 2.4. People: Fixture Type Recessed (Unvented) Occupancy 3.0 People Wattage 0.89 W/ft2 Activity Level Office Work Ballast Multiplier 1.08 Sensible 245.0 BTU/hr/person . 901 Office Ligc Latenthts/Ele Schedule 205.0 BTU/hr/person Schedule 90.1 Office Occupants 2.2. Task Lighting: Wattage Schedule 2.3. Electrical Equipment: Wattage Schedule 3. Walls, Windows, Doors: 2.5. Miscellaneous Loads: 0.00 W/ft2 Sensible 0 BTU/hr None Schedule None Latent 0 BTU/hr Schedule None 145.0 Watts 90.1 Office Lights/Elec Exp. Wall Gross Area (ft2) Window 1 Qty. Window 2 Qty. Door 1 Qty. W 221.0 72 0 0 3.1. Construction Types for Exposure W Wall Type NOTE1: below grade walls same as above grade 1st Window Type Existing Glazing 4. Roofs, Skylights: (No Roof or Skylight data). 5. Infiltration: Design Cooling 0.00 CFM Design Heating 0.05 ACH Energy Analysis 0.00 CFM Infiltration occurs at all hours. 6. Floors: Type Floor Above Conditioned Space (No additional input required for this floor type). 7. Partitions: (No partition data). Hourly Analysis Program v5.11 Page 4 of 13 `TUK_SAB`EY_IGW-C_LEVEL 3RD FL -1_v5_11 HERMANSON COMPANY LLP Space Input Data 03-05 Office 09/05/2018 10:30AM 1. General Details: Floor Area 221.0 ft2 Avg. Ceiling Height 9.0 ft Building Weight 70.0 Ib/ft2 1.1. OA Ventilation Requirements: Space Usage User -Defined OA Requirement 1 5.0 CFM/person OA Requirement 2 0.06 CFM/ft2 Space Usage Defaults ASHRAE Std 62.1-2010 2. Internals: 2.1. Overhead Lighting: 2.4. People: Fixture Type Recessed (Unvented) Occupancy 3.0 People Wattage 0.89 W/ft2 Activity Level Office Work Ballast Multiplier 1.08 Sensible 245.0 BTU/hr/person Schedule 90.1 Office Lights/Elec Latent 205.0 BTU/hr/person Schedule 90.1 Office Occupants 2.2. Task Lighting: Wattage Schedule 2.3. Electrical Equipment: Wattage Schedule 3. Walls, Windows, Doors: 2.5. Miscellaneous Loads: 0.00 W/ft2 Sensible 0 BTU/hr None Schedule None Latent 0 BTU/hr Schedule None 143.0 Watts 90.1 Office Lights/Elec Exp. Wall Gross Area (ft2) Window 1 Qty. Window 2 Qty. Door 1 Qty. W 221.0 72 0 0 3.1. Construction Types for Exposure W Wall Type 1st Window Type 4. Roofs, Skylights: (No Roof or Skylight data). 5. Infiltration: Design Cooling Design Heating Energy Analysis Infiltration occurs at all hours. Existing Wall Existing Glazing 0.00 CFM 0.00 ACH 0.00 CFM 6. Floors: Type Floor Above Conditioned Space (No additional input required for this floor type). 7. Partitions: (No partition data). Hourly Analysis Program v5.11 Page 5 of 13 Space Input Data TUK_SAbEY_IGW-C_LEVEL 3RD FL-1_v5_11 09/05/2018 HERMANSON COMPANY LLP 10:30AM 03-06 Conference 1. General Details: Floor Area 406.0 ft2 Avg. Ceiling Height 9.0 ft Building Weight 70.0 Ib/ft2 1.1. OA Ventilation Requirements: Space Usage User -Defined OA Requirement 1 5.0 CFM/person OA Requirement 2 0.06 CFM/ft2 Space Usage Defaults ASHRAE Std 62.1-2010 2. Internals: 2.1. Overhead Lighting: 2.4. People: Fixture Type Recessed (Unvented) Occupancy 16.0 People Wattage 0.89 W/ft2 Activity Level Office Work Ballast Multiplier 1.08 Sensible 245.0 BTU/hr/person Schedule 90.1 Office Lights/Elec Latent 205.0 BTU/hr/person Schedule 90.1 Office Occupants 2.2. Task Lighting: Wattage Schedule 2.3. Electrical Equipment: Wattage Schedule 3. Walls, Windows, Doors: 2.5. Miscellaneous Loads: 0.00 W/ft2 Sensible 0 BTU/hr None Schedule None Latent 0 BTU/hr Schedule None 1.50 W/ft2 90.1 Office Lights/Elec Exp. Wall Gross Area (ft2) Window 1 Qty. Window 2 Qty. Door 1 Qty. W 364.0 100 0 0 3.1. Construction Types for Exposure W Wall Type 1st Window Type 4. Roofs, Skylights: (No Roof or Skylight data). 5. Infiltration: Design Cooling Design Heating Energy Analysis Infiltration occurs at all hours. Existing Wall Existing Glazing 0.00 CFM 0.00 ACH 0.00 CFM 6. Floors: Type Floor Above Conditioned Space (No additional input required for this floor type). 7. Partitions: (No partition data). Hourly Analysis Program v5.11 Page 6 of 13 TUK_SAI#EY_IGW-C_LEVEL 3RD FL -1_v5_11 HERMANSON COMPANY LLP Space Input Data 03-07 Server Room 09/05/2018 .10:30AM 1. General Details: Floor Area 100.0 ft2 Avg. Ceiling Height 9.0 ft Building Weight 70.0 lb/ft2 1.1. OA Ventilation Requirements: Space Usage User -Defined OA Requirement 1 5.0 CFM/person OA Requirement 2 0.06 CFM/ft2 Space Usage Defaults ASHRAE Std 62.1-2010 2. Internals: 2.1. Overhead Lighting: 2.4. People: Fixture Type Recessed (Unvented) Occupancy 0.0 Person Wattage 0.89 W/ft2 Activity Level Office Work Ballast Multiplier 1.08 Sensible 245.0 BTU/hr/person Schedule 90.1 Office Lights/Elec Latent 205.0 BTU/hr/person Schedule None 2.2. Task Lighting: Wattage Schedule 2.3. Electrical Equipment: Wattage Schedule 3. Walls, Windows, Doors: 2.5. Miscellaneous Loads: 0.00 W/ft2 Sensible 0 BTU/hr None Schedule None Latent 0 BTU/hr Schedule None 4.00 W/ft2 90.1 Office Lights/Elec Exp. Wall Gross Area (ft2) Window 1 Qty. Window 2 Qty. Door 1 Qty. W 130.0 50 0 0 3.1. Construction Types for Exposure W Wall Type 1st Window Type 4. Roofs, Skylights: (No Roof or Skylight data). 5. Infiltration: Design Cooling Design Heating Energy Analysis Infiltration occurs at all hours. Existing Wall Existing Glazing 0.00 CFM 0.00 ACH 0.00 CFM 6. Floors: Type Floor Above Conditioned Space (No additional input required for this floor type). 7. Partitions: (No partition data). Hourly Analysis Program v5.11 Page 7 of 13 TUK_SAI§EY_IGW-C_LEVEL 3RD FL -1_v5_11 HERMANSON COMPANY LLP Space Input Data 03-08 Copier Room 09/05/2018 10:30AM 1. General Details: Floor Area 363.0 ft2 Avg. Ceiling Height 9.0 ft Building Weight 70.0 lb/ft2 1.1. OA Ventilation Requirements: Space Usage User -Defined OA Requirement 1 5.0 CFM/person OA Requirement 2 0.06 CFM/ft2 Space Usage Defaults ASHRAE Std 62.1-2010 2. Internals: 2.1. Overhead Lighting: Fixture Type Wattage Ballast Multiplier Schedule 2.2. Task Lighting: Wattage Schedule 2.3. Electrical Equipment: Wattage Schedule 3. Walls, Windows, Doors: Recessed (Unvented) 0.89 W/ft2 1.08 90.1 Office Lights/Elec 0.00 W/ft2 None 1850.0 Watts 90.1 Office Lights/Elec 2.4. People: Occupancy Activity Level Sensible Latent Schedule 2.5. Miscellaneous Loads: Sensible Schedule Latent Schedule Exp. W Wall Gross Area (ft2) Window 1 Qty. Window 2 Qty. Door 1 Qty. 390.0 125 0 0 3.1. Construction Types for Exposure W Wall Type 1st Window Type 4. Roofs, Skylights: (No Roof or Skylight data). 5. Infiltration: Design Cooling Design Heating Energy Analysis Infiltration occurs at all hours. Existing Wall Existing Glazing 0.00 CFM 0.00 ACH 0.00 CFM 6. Floors: Type Floor Above Unconditioned Space Floor Area 363.0 ft2 Total Floor U -Value 0.420 BTU/(hrft2•°F) Unconditioned Space Max Temp. 82.0 °F Ambient at Space Max Temp. 82.0 °F Unconditioned Space Min Temp. 44.0 °F Ambient at Space Min Temp. 24.0 °F 7. Partitions: (No partition data). Hourly Analysis Program v5.11 3.0 People Office Work 245.0 BTU/hr/person 205.0 BTU/hr/person 9C.1 Office Occupants 0 BTU/hr None 0 BTU/hr None Page 8 of 13 TUK_SA6EY_IGW-C_LEVEL 3RD FL-1_v5_11 HERMANSON COMPANY LLP Space Input Data 03-09 Break Rm-Kitchen 09/05/2018 10:30AM 1. General Details: Floor Area 369.0 ft2 Avg. Ceiling Height 9.0 ft Building Weight 70.0 Ib/ft2 1.1. OA Ventilation Requirements: Space Usage User -Defined OA Requirement 1 5.0 CFM/person OA Requirement 2 0.06 CFM/ft2 Space Usage Defaults ASHRAE Std 62.1-2010 2. Internals: 2.1. Overhead Lighting: Fixture Type Wattage Ballast Multiplier Schedule 2.2. Task Lighting: Wattage Schedule 2.3. Electrical Equipment: Wattage Schedule 3. Walls, Windows, Doors: Exp. W i Recessed (Unvented) 0.89 W/ft2 1.08 90.1 Office Lights/Elec 0.00 W/ft2 None 550.0 Watts 90.1 Office Lights/Elec 2.4. People: Occupancy Activity Level Sensible Latent Schedule 2.5. Miscellaneous Loads: Sensible Schedule Latent Schedule Wall Gross Area (ft2) 169.0 I Window 1 Qty. I Window 2 Qty. I 50 0 3.1. Construction Types for Exposure W Wall Type 1st Window Type 4. Roofs, Skylights: (No Roof or Skylight data). 5. Infiltration: Design Cooling Design Heating Energy Analysis Infiltration occurs at all hours. Existing Wall Existing Glazing 0.00 CFM 0.00 ACH 0.00 CFM 6. Floors: Type Floor Above Conditioned Space (No additional input required for this floor type). 7. Partitions: (No partition data). Hourly Analysis Program v5.11 Door 1 Qty. 0 10.0 People Office Work 245.0 BTU/hr/person 205.0 BTU/hr/person 90.1 Office Occupants 0 BTU/hr None 0 BTU/hr None Page 9 of 13 TUK_SABEY_IGW-C_LEVEL 3RD FL -1_v5_11 HERMANSON COMPANY LLP Space Input Data 03-10 Reception 09/05/2018 10:30AM 1. General Details: Floor Area 580.0 ft2 Avg. Ceiling Height 9.0 ft Building Weight 70.0 lb/ft' 1.1. OA Ventilation Requirements: Space Usage User -Defined OA Requirement 1 5.0 CFM/person OA Requirement 2 0.06 CFM/ft2 Space Usage Defaults ASHRAE Std 62.1-2010 2. Internals: 2.1. Overhead Lighting: 2.4. People: Fixture Type Recessed (Unvented) Occupancy 4.0 People Wattage 0.89 W/ft2 Activity Level Office Work Ballast Multiplier 1.08 Sensible 245.0 BTU/hr/person Schedule 90.1 Office Lights/Elec Latent 205.0 BTU/hr/person Schedule 90 1 Office Occupants 2.2. Task Lighting: 2.5. Miscellaneous Loads: Wattage 0.00 W/ft2 Sensible 0 BTU/hr Schedule None Schedule None Latent 0 BTU/hr Schedule None 2.3. Electrical Equipment: Wattage Schedule 145.0 Watts 90.1 Office Lights/Elec 3. Walls, Windows, Doors: (No Wall, Window, Door data). 4. Roofs, Skylights: (No Roof or Skylight data). 5. Infiltration: Design Cooling Design Heating Energy Analysis Infiltration occurs at all hours. 0.00 CFM 0.00 ACH 0.00 CFM 6. Floors: Type Floor Above Conditioned Space (No additional input required for this floor type). 7. Partitions: (No partition data). Hourly Analysis Program v5.11 Page 10 of 13 TUK_SALEY_IGW-C_LEVEL 3RD FL-1_v5_11 HERMANSON COMPANY LLP Space Input Data 03-11 Office 09/05/20'18 10:30AM 1. General Details: Floor Area 203.0 ft2 Avg. Ceiling Height 9.0 ft Building Weight 70.0 Ib/ft2 1.1. OA Ventilation Requirements: Space Usage User -Defined OA Requirement 1 5.0 CFM/person OA Requirement 2 0.06 CFM/ft2 Space Usage Defaults ASHRAE Std 62.1-2010 2. Internals: 2.1. Overhead Lighting: Fixture Type Wattage Ballast Multiplier Schedule 2.2. Task Lighting: Wattage Schedule 2.3. Electrical Equipment: Wattage Schedule Recessed (Unvented) 0.89 W/ft2 1.08 90.1 Office Lights/Elec 0.00 W/ft2 None 145.0 Watts 90.1 Office Lights/Elec 3. Walls, Windows, Doors: (No Wall, Window, Door data). 4. Roofs, Skylights: (No Roof or Skylight data). 5. Infiltration: Design Cooling Design Heating Energy Analysis Infiltration occurs at all hours. 0.00 CFM 0.00 ACH 0.00 CFM 6. Floors: Type Floor Above Conditioned Space (No additional input required for this floor type). 7. Partitions: (No partition data). Hourly Analysis Program v5.11 2.4. People: Occupancy Activity Level Sensible Latent Schedule 2.5. Miscellaneous Loads: Sensible Schedule Latent Schedule 3.0 People Office Work 245.0 BTU/hr/person 205.0 BTU/hr/person 90.1 Office Occupants 0 BTU/hr None 0 BTU/hr None Page 11 of 13 TUK_SABEY_IGW-C_LEVEL 3RD FL-1_v5_11 HERMANSON COMPANY LLP Space Input Data 03-12 Storage 09/05/2018 10:30AM 1. General Details: Floor Area 321.0 ft2 Avg. Ceiling Height 9.0 ft Building Weight 70.0 Ib/ft2 1.1. OA Ventilation Requirements: Space Usage User -Defined OA Requirement 1 5.0 CFM/person OA Requirement 2 0.06 CFM/ft2 Space Usage Defaults ASHRAE Std 62.1-2010 2. Internals: 2.1. Overhead Lighting: 2.4. People: Fixture Type Recessed (Unvented) Occupancy 0.0 Person Wattage 0.89 W/ft2 Activity Level Office Work Ballast Multiplier 1.08 Sensible 245.0 BTU/hr/person Schedule 90.1 Office Lights/Elec Latent 205.0 BTU/hr/person Schedule None 2.2. Task Lighting: 2.5. Miscellaneous Loads: Wattage 0.00 W/ft2 Sensible 0 BTU/hr Schedule None Schedule None 2.3. Electrical Equipment: Wattage Schedule 0.0 Watts 90.1 Office Lights/Elec 3. Walls, Windows, Doors: (No Wall, Window, Door data). 4. Roofs, Skylights: (No Roof or Skylight data). 5. Infiltration: Design Cooling Design Heating Energy Analysis Infiltration occurs at all hours. 0.00 CFM 0.00 ACH 0.00 CFM 6. Floors: Type Floor Above Conditioned Space (No additional input required for this floor type). 7. Partitions: (No partition data). Latent 0 BTU/hr Schedule None Hourly Analysis Program v5.11 Page 12 of 13 TUK_SABEY_IGW-C_LEVEL 3RD FL -1 v5 11 HERMANSON COMPANY LLP Space Input Data 03-13 Open Office -Hall 09/05/2018 10:30AM 1. General Details: Floor Area 887.0 ft2 Avg. Ceiling Height 9.0 ft Building Weight 70.0 lb/ft2 1.1. OA Ventilation Requirements: Space Usage User -Defined OA Requirement 1 5.0 CFM/person OA Requirement 2 0.06 CFM/ft2 Space Usage Defaults ASHRAE Std 62.1-2010 2. Internals: 2.1. Overhead Lighting: Fixture Type Wattage Ballast Multiplier Schedule 2.2. Task Lighting: Wattage Schedule 2.3. Electrical Equipment: Wattage Schedule Recessed (Unvented) 0.89 W/ft2 1.08 90.1 Office Lights/Elec 0.00 W/ft2 None 290.0 Watts 90.1 Office Lights/Elec 3. Walls, Windows, Doors: (No Wall, Window, Door data). 4. Roofs, Skylights: (No Roof or Skylight data). 5. Infiltration: Design Cooling Design Heating Energy Analysis Infiltration occurs at all hours. 0.00 CFM 0.00 ACH 0.00 CFM 6. Floors: Type Floor Above Conditioned Space (No additional input required for this floor type). 7. Partitions: (No partition data). Hourly Analysis Program v5.11 2.4. People: Occupancy Activity Level Sensible Latent Schedule 2.5. Miscellaneous Loads: Sensible .. Schedule Latent Schedule 4.0 People Office Work 245.0 BTU/hr/person 205.0 BTU/hr/person 90.1 Office Occupants 0 BTU/hr None 0 BTU/hr None Page 13 of 13 Hermanson Building Today, Defining Tomorrow Hermanson Company LLP 1221 2nd Avenue North Kent, WA 98032 tel 206-575-9700 fax 206-575-9800 Project: 12101 Tukwila International Blvd, Tukwila Date: 09/05/2018 Hermanson Building Today, Defining Tomorrow HVAC SYSTEM COOLING/HEATING CALCS CARRIER HAP VERSION: 5.11 SYSTEM INPUTS Mechanical Construction, Engineering and Service www.hermanson.com Project Name: TUK_SABEY_IGW-C_LEVEL 3RD FL -1_v5_11 Prepared by: HERMANSON COMPANY LLP VAV Input Data 09/05/2018 10:31 AM . General Details: Air System Name VAV Equipment Type Packaged Rooftop Units Air System Type VAV Number of zones 1 2. Ventilation System Components: Ventilation Air Data: Airflow Control Constant Ventilation Airflow Ventilation Sizing Method ASHRAE Std 62.1-2010 Unocc. Damper Position Closed Damper Leak Rate 5 Outdoor Air CO2 Level 400 ppm Economizer Data: Control Integrated enthalpy control Upper Cutoff 75.0 °F Lower Cutoff 35.0 °F Central Cooling Data: Supply Air Temperature 55.0 °F Coil Bypass Factor 0.100 Cooling Source Air -Cooled DX Schedule JFMAMJJASOND Capacity Control Cycled or Staged Capacity - Fan On Supply Fan Data: Fan Type Configuration Fan Performance Overall Efficiency Forward Curved with Variable Frequency Drive Draw-thru 4.00 in wg 48 % % Airflow 100 90 80 70 60 50 % kW 100 77 60 44 35 25 % Airflow 40 30 20 10 0 %kW 19 13 9 7 6 Duct System Data: Supply Duct Data: Duct Heat Gain Duct Leakage Return Duct or Plenum Data: Return Air Via Wall Heat Gain to Plenum Roof Heat Gain to Plenum Lighting Heat Gain to Plenum 3. Zone Components: Space Assignments: 3 % 2 Return Air Plenum 20 % 80 % 30 % Zone 1: Zone 1 03-01 Office x1 03-02 Office x1 03-03 Office x1 03-04 Office x1 03-05 Office x1 03-06 Conference x1 03-07 Server Room x1 03-08 Copier Room x1 03-09 Break Rm-Kitchen x1 03-10 Reception x1 03-11 Office x1 03-12 Storage x1 03-13 Open Office -Hall x1 Hourly Analysis Program 5.11 Page 1 of 2 Project Name: TUK_SABEY_IGW-C_LEVEL 3RD FL -1_v5_11 Prepared by: HERMANSON COMPANY LLP VAV Input Data 09/05/20'18 10:31 AM Thermostats and Zone Data: Zone Cooling T-Stat Occ. (°F) Cooling T-Stat Unocc. (°F) Heating T-Stat Occ. (°F) Heating T-Stat Unocc. (°F) T-Stat Throttling Range (°F) Diversity Factor (%) Direct Exhaust Airflow (CFM) Direct Exhaust Fari (kW) 1 75.0 80.0 72.0 55.0 1.00 100 0.0 0.0 Thermostat Schedule Unoccupied Cooling is Supply Terminals Data: 90.1 Office HVAC Available Zone Terminal Type Air Distribution Air Distribution Effectiveness Specification Air Distribution Effectiveness Minimum Airflow Fan Performance Fan Efficiency Design Supply Temp. 1 Series FPMBX with reheat Ceiling supply / ceiling return ASHRAE 62.1 <auto> 30 % 0.30 in wg 70 % 86.9 °F Reheat Coil Source Reheat Coil Schedule Zone Heating Units: Zone Unit Heat Source Zone Heating Unit Schedule 4. Sizing Data (Computer -Generated): System Sizing Data: Sizing Data: Cooling Supply Temperature Supply Fan Airflow Ventilation Airflow Hydronic Sizing Specifications: Chilled Water Delta -T Hot Water Delta -T Safety Factors: Cooling Sensible Cooling Latent Heating Zone Sizing Data: Zone Airflow Sizing Method Space Airflow Sizing Method Electric Resistance JFMAMJJASOND Electric Resistance JFMAMJJASOND 55.0 °F 3888.5 CFM 926.4 CFM 10.0 °F 30.0 °F 0 % 0 % 0 % Peak zone sensible load Individual peak space loads Zone Supply Airflow (CFM) Zone Htg Unit (MBH) Reheat Coil (MBH) FPMBX Fan (CFM) 1 3810.8 - 81.0 3810.8 5. Equipment Data Central Cooling Unit - Air -Cooled DX Estimated Maximum Load Design OAT Equipment Sizing Gross Cooling Capacity Compressor & OD Fan Power Conventional Cutoff OAT Low Temperature Operation 134.7 MBH 95.0 °F User -Defined 1.0 MBH 1.000 kW 55.0 °F Not used Hourly Analysis Program 5.11 Page 2 of 2 Hermanson Ii Building Today. Defining Tomorrow Hermanson Company LLP 1221 2nd Avenue North Kent, WA 98032 tei 206-575-9700 fax 206-575-9800 Project: 12101 Tukwila International Blvd, Tukwila Date: 09/05/2018 Hermanson Building Today, Defining Tomorrow HVAC SYSTEM COOLING/HEATING CALCS CARRIER HAP VERSION: 5.11 SYSTEM OUTPUTS Mechanical Construction, (Engineering and Service www.hermanson.com Air System Sizing Summary for VAV Project Name: TUK_SABEY_IGW-C_LEVEL 3RD FL -1_v5_11 09/05/2018 Prepared by: HERMANSON COMPANY LLP 10:34AM Air System Information Air System Name VAV Number of zones 1 Equipment Class PKG ROOF Floor Area 4485.0 ft' Air System Type VAV Location Seattle IAP, Washington Sizing Calculation Information Calculation Months Jan to Dec Zone CFM Sizing Peak zone sensible load Sizing Data Calculated Space CFM Sizing Individual peak space loads Central Cooling Coil Sizing Data Total coil load 11.2 Tons Load occurs at Jun 1600 Total coil load 134.7 MBH OA DB / WB 84.5 / 66.9 °F Sensible coil load 113.1 MBH Entering DB / WB 78.6 / 62.5 °F Coil CFM at Jun 1600 3889 CFM Leaving DB / WB 51.3 / 49.9 °F Max block CFM at Jun 1700 3889 CFM Coil ADP 48.2 °F Sum of peak zone CFM 3889 CFM Bypass Factor 0.100 Sensible heat ratio 0.839 Resulting RH 42 CFM/Ton 346.4 Design supply temp. 55.0 °F ft2/Ton 399.5 Zone T -stat Check 0 of 1 OK BTU/(hr•ft2) 30.0 Max zone temperature deviation 0.0 °F Water flow @ 10.0 °F rise N/A Supply Fan Sizing Data Actual max CFM at Jun 1700 Standard CFM Actual max CFM/ft2 3889 CFM 3826 CFM 0.87 CFM/ft2 Fan motor BHP Fan motor kW Fan static 4.79 BHP 3.80 kW 4.00 in wg Outdoor Ventilation Air Data Design airflow CFM 926 CFM CFM/person 15.70 CFM/person CFM/ft2 0.21 CFM/ft2 p Hourly Analysis Program 5.11 Page 1 of 20 Zone Sizing Summary for VAV Project Name: TUK_SABEY_IGW-C_LEVEL 3RD FL -1_v5_11 09/05/2018 Prepared by: HERMANSON COMPANY LLP 10:34AM Air System Information Air System Name VAV Number of zones 1 Equipment Class PKG ROOF Floor Area 4485.0 ft2 Air System Type VAV Location Seattle IAP, Washington Sizing Calculation Information Calculation Months Jan to Dec Sizing Data Calculated Zone Terminal Sizing Data Zone CFM Sizing Peak zone sensible load Space CFM Sizing Individual peak space loads Zone Name Design Supply Airflow (CFM) Minimum Supply Airflow (CFM) Zone CFM/ft2 Reheat Coil Load (MBH) Reheat Coil Water gpm @ 30.0 °F Zone Htg Unit Coil Load (MBH) Zone Htg Unit Water gpm @ 30.0 °F Mixing Box Fan Airflow Zone 3811 1143 0.85 81.0 - 0.0 - (CFM) 3811 1 6.6 Jun 1700 Zone Peak Sensible Loads Zone Name Zone Cooling Sensible (MBH) Time of Peak Sensible Cooling Load Zone Heating Load (MBH) Zone Floor Area (ft2) Zone 1 80.3 Jun 1700 39.6 4485.0 Space Loads and Airflows Hourly Analysis Program 5.11 Page 2 of 20 Zone Name / Space Name Mult. Cooling Sensible (MBH) Time of Peak Sensible Load Air Flow (CFM) Heating Load (MBH) Floor Area (ft2) Space CFM/ft2 Zone 1 03-01 Office 1 6.6 Jun 1700 310 5.9 285.0 1.09 03-02 Office 1 3.6 Jun 1800 172 4.2 283.0 0.61 03-03 Office 1 8.3 Jun 1400 390 6.9 324.0 1.20 03-04 Office 1 6.0 Jun 1700 282 2.7 143.0 1.97 03-05 Office 1 6.2 Jun 1700 290 2.8 221.0 1.31 03-06 Conference 1 12.7 Jun 1700 598 4.1 406.0 1.47 03-07 Server Room 1 4.7 Jun 1700 221 1.8 100.0 2.21 03-08 Copier Room 1 16.3 Jun 1700 769 9.1 363.0 2.12 03-09 Break Rm-Kitchen 1 7.9 Jun 1700 373 2.0 369.0 1.01 03-10 Reception 1 2.6 Jan 2100 123 0.0 580.0 0.21 03-11 Office 1 1.6 Jan 2100 74 0.0 203.0 0.37 03-12 Storage 1 0.7 Jan 2200 33 0.0 321.0 0.10 03-13 Open Office -Hall 1 3.8 Jan 2100 177 0.0 887.0 0.20 Hourly Analysis Program 5.11 Page 2 of 20 Ventilation Sizing Summary for VAV Project Name: TUK_SABEY_IGW-C_LEVEL 3RD FL -1_v5_11 Prepared by: HERMANSON COMPANY LLP 09/05/2018 10:34AM 1. Summary Ventilation Sizing Method Design Condition Occupant Diversity (D) Uncorrected Outdoor Air Intake (Vou) System Ventilation Efficiency (Ev) Outdoor Air Intake (Vot) 2. Space Ventilation Analysis ASHRAE Std 62.1-2010 Minimum flow (cooling) 1.000 564 CFM 0.609 926 CFM Hourly Analysis Program 5.11 Page 3 of 20 Minimum Supply Air (CFM) Space Floor Area (ft2) Area Outdoor Air Rate (CFM/ft2) Time Averaged Occupancy (Occupants) ' Peo7e Outdoor Air Rate (CFM/person) Air Distribution Effectiveness Space Outdoor Air (CFM) Breathing Zone Outdoor Air (CFM) Space Ventilation Efficiency Zone Name / Space Name Mult. (Vpz) (Az) (Ra) (Pz) (Rp) (Ez) (Voz) (Vbz) (Evz) Zone 1 03-01 Office 1 93 285.0 0.06 3.0 5.00 1.0 32 32 1.059 03-02 Office 1 52 283.0 0.06 3.0 5.00 1.0 32 32 0.932 03-03 Office 1 117 324.0 0.06 7.0 5.00 1.0 54 54 1.003 03-04 Office 1 85 143.0 0.06 3.0 5.00 1.0 24 24 1.089 03-05 Office 1 87 221.0 0.06 3.0 5.00 1.0 28 28 1.068 03-06 Conference 1 179 406.0 0.06 16.0 5.00 1.0 104 104 0.949 03-07 Server Room 1 66 100.0 0.06 0.0 5.00 1.0 6 6 1.176 03-08 Copier Room 1 231 363.0 0.06 3.0 5.00 1.0 37 37 1.144 03-09 Break Rm-Kitchen 1 112 369.0 0.06 10.0 5.00 1.0 72 72 0.920 03-10 Reception 1 55 580.0 0.06 4.0 5.00 1.0 55 55 0.674 03-11 Office 1 27 203.0 0.06 3.0 5.00 1.0 27 27 0.717 03-12 Storage 1 19 321.0 0.06 0.0 5.00 1.0 19 19 0.609 03-13 Open Office -Hall 1 73 887.0 0.06 4.0 5.00 1.0 73 73 0.691 Totals (incl. Space Multipliers) 1196 564 0.609 Hourly Analysis Program 5.11 Page 3 of 20 Air System Design Load Summary for VAV Project Name: TUK_SABEY_IGW-C_LEVEL 3RD FL -1_v5_11 Prepared by: HERMANSON COMPANY LLP 09/05/2018 10:34AM Hourly Analysis Program 5.11 Page 4 of 20 DESIGN COOLING DESIGN HEATING COOLING DATA AT Jun 1600 COOLING OA DB / WB 84.5 °F / 66.9 °F HEATING DATA AT DES HTG HEATING OA DB f WB 24.0 °F / 19.2 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 824 ft2 34750 - 824 ft2 - - Wall Transmission 1783 ft2 1639 - 1783 ft2 9712 - Roof Transmission 0 ft2 0 - 0 ft2 0 - Window Transmission 824 ft2 3029 - 824 ft2 22149 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 0 ft2 0 - 0 ft2 0 - Floor Transmission 363 ft2 839 - 363 ft2 4269 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 4311 W 9429 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 5002 W 16425 - 0 0 - People 59 12308 12095 0 0 0 Infiltration - 0 0 3467 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 78418 12095 - 39597 0 Zone Conditioning - 85153 12095 - 37324 0 Plenum Wall Load 20% 681 - 0 0 - Plenum Roof Load 80% 0 - 0 0 - Plenum Lighting Load 30% 4413 - 0 0 - Return Fan Load 3889 CFM 0 - 1167 CFM 0 - Ventilation Load 926 CFM 7502 9533 926 CFM 44982 0 Supply Fan Load 3889 CFM 12972 - 1167 CFM -1686 - Space Fan Coil Fans - 654 - - -654 - Duct Heat Gain / Loss 3% 2353 - 3% 1188 - » Total System Loads - 113727 21628 - 81153 0 Central Cooling Coil - 113073 21630 - 0 0 Terminal Reheat Coils - 0 - - 80332 - » Total Conditioning - 113073 21630 - 80332 0 Key: Positive values are clg loads Negative values are htg loads Positive values are htg Negative values are clg loads loads Hourly Analysis Program 5.11 Page 4 of 20 Project Name: TUK_SABEY_IGW-C_LEVEL 3RD FL -1_v5_11 Prepared by: HERMANSON COMPANY LLP Zone Design Load Summary for VAV 09/05/2018 10:34AM Zone 1 DESIGN COOLING DESIGN HEATING COOLING DATA AT Jun 1700 COOLING OA DB / WB 83.2 °F / 66.4 °F HEATING DATA AT DES HTG HEATING OA DB / WB 24.0 °F / 19.2 °F OCCUPIED T -STAT 75.0 °F OCCUPIED T -STAT 72.0 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 824 ft2 36435 - 824 ft2 - - Wall Transmission 1783 ft2 1928 - 1783 ft2 9712 - Roof Transmission 0 ft2 0 - 0 ft2 0 - Window Transmission 824 ft2 2714 - 824 ft2 22149 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 0 ft2 0 - 0 ft2 0 - Floor Transmission 363 ft2 854 - 363 ft2 4269 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 4311 W 9486 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 5002 W 16467 - 0 0 - People 59 12449 12095 0 0 0 Infiltration - 0 0 - 3467 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 80332 12095 - 39597 0 Hourly Analysis Program 5.11 Page 5 of 20 Space Design Load Summary for VAV Project Name: TUK_SABEY_IGW-C LEVEL 3RD FL -1_v5_11 Prepared by: HERMANSON COMPANY LLP 09/05/2018 10:34AM TABLE 1.1.A. Component Loads For Space "03-01 Office" In Zone "Zone 1" TABLE 1.1.B. Envelope Loads For Space "03-01 Office' In Zone "Zone 1" DESIGN COOLING DESIGN HEATING COOLING DATA AT Jun 1700 COOLING OA DB / WB 83.2 °F / 66.4 °F OCCUPIED T -STAT 75.0 °F HEATING DATA AT DES HTG HEATING OA DB i WB 24.0 °F / 19.2 °F OCCUPIED T -STAT 72.0 °F COOLING HEATING Sensible Latent U -Value Sensible Latent SPACE LOADS Details (BTU/hr) (BTU/hr) Details (BTU/hr) (BTU/hr) Window & Skylight Solar Loads 117 ft2 4199 - 117 ft2 Wall Transmission 312 ft2 289 - 312 ft' 1713 187 Roof Transmission 0 ft2 0 - 0 ft2 0 181 Window Transmission 117 ft2 385 - 117 ft2 3145 Skylight Transmission 0 ft2 0 - 0 ft2 0 102 Door Loads 0 ft2 0 - 0 ft2 0 204 Floor Transmission 0 ft2 0 - 0 ft2 0 Partitions 0 ft2 0 - 0 ft2 0 Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 274 W 603 - 0 0 Task Lighting 0 W 0 - 0 0 Electric Equipment 145 W 477 - 0 0 People 3 633 615 0 0 0 Infiltration - 0 0 1090 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 6586 615 - 5948 0 Hourly Analysis Program 5.11 Page 6 of 20 TABLE 1.1.B. Envelope Loads For Space "03-01 Office' In Zone "Zone 1" COOLING COOLING HEATING Area U -Value Shade TRANS SOLAR TRANS (ft2) (BTU/(hrft2•°F)) Coeff. (BTU/hr) (BTU/hr) (BTU/hr) W EXPOSURE WALL 147 0.114 - 187 - 804 WINDOW 1 55 0.560 0.570 181 3184 1478 N EXPOSURE WALL 166 0.114 - 102 - 908 WINDOW 1 62 0.560 0.570 204 1015 1667 Hourly Analysis Program 5.11 Page 6 of 20 Space Design Load Summary for VAV Project Name: TUK_SABEYIGW-C_LEVEL 3RD FL -1_v5_11 Prepared by: HERMANSON COMPANY LLP 09/05/2018 10:34AM •.-...- ,. ...•. ..i/,nNUnent Loaas ror space "03-02 Office" In Zone "Zone 1" DESIGN COOLING DESIGN HEATING COOLING DATA AT Jun 1800 COOLING OA DB / WB 81.2 °F / 65.8 °F OCCUPIED T -STAT 75.0 °F HEATING DATA AT DES HTG HEATING OA DB / WB 24.0 °F / 19.2 °F OCCUPIED T -STAT 72.0 °F HEATING Sensible Latent Shade Sensible Latent SPACE LOADS Details (BTU/hr) (BTU/hr) Details (BTU/hr) (BTU/hr) Window & Skylight Solar Loads 88 ft2 1612 - 88 ft2 - Wall Transmission 140 ft2 88 - 140 ft2 766 - Roof Transmission 0 ft2 0 - 0 ft2 0 1612 Window Transmission 88 ft2 230 - 88 ft2 2365 - Skylight Transmission 0 ft2 0 - 0 ft2 0 Door Loads 0 ft2 0 - 0 ft2 0 Floor Transmission 0 ft2 0 - 0 ft2 0 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft' 0 - 0 ft2 0 - Overhead Lighting 272 W 602 - 0 0 - Task Lighting 0 W 0 - 0 0 Electric Equipment 145 W 479 - 0 0 People 3 640 615 0 0 0 Infiltration - 0 0 1083 0 Miscellaneous- 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 3649 615 - 4214 0 -----.-.- -•c.•u• ",.ewNe waus ror space U3-02 Office' In Zone "Zone 1" COOLING COOLING HEATING Area U -Value Shade TRANS SOLAR TRANS (ft2) (BTU/(hr•ft2•°F)) Coeff. (BTU/hr) (BTU/hr) (BTU/hr) N EXPOSURE WALL 140 0.114 - 88766 - WINDOW 1 88 0.560 0.570 230 1612 2365 Hourly Analysis Program 5.11 Page 7 of 20 Space Design Load Summary for VAV Project Name: TUK_SABEY_IGW-C_LEVEL 3RD FL -1_v5_11 Prepared by: HERMANSON COMPANY LLP 09/05/2018 10:34AM TABLE 1.3.A. Component Loads For Space "03-03 Office" In Zone "Zone 1" DESIGN COOLING DESIGN HEATING COOLING DATA AT Jun 1400 COOLING OA DB / WB 84.5 °F / 66.9 °F OCCUPIED T -STAT 75.0 °F HEATING DATA AT DES HTG HEATING OA DB 1 WB 24.0 °F / 19.2 °F OCCUPIED T -STAT 72.0 °F HEATING Sensible Latent Shade Sensible Latent SPACE LOADS Details (BTU/hr) (BTU/hr) Details (BTU/hr) (BTU/hr) Window & Skylight Solar Loads 150 ft2 3983 - 150 ft2 - - Wall Transmission 305 ft2 263 - 305 ft2 1674 - Roof Transmission 0 ft2 0 - 0 ft2 0 - Window Transmission 150 ft2 515 - 150 ft2 4032 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 0 ft2 0 - 0 ft2 0 - Floor Transmission 0 ft2 0 - 0 ft2 0 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 311 W 672 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 435 W 1420 - 0 0 - People 7 1423 1435 0 0 0 Infiltration - 0 0 - 1239 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 8277 1435 - 6946 0 TABLE 1.3.B. Envelope Loads For Space "03-03 Office' In Zone "Zone 1" COOLING COOLING HEATING Area U -Value Shade TRANS SOLAR TRANS (ft2) (BTU/(hrft2•°F)) Coeff. (BTU/hr) (BTU/hr) (BTU/hr) N EXPOSURE WALL 179 0.114 - 75 - 980 WINDOW 1 75 0.560 0.570 257 1165 2016 E EXPOSURE WALL 127 0.114 - 188 - 694 WINDOW 1 75 0.560 0.570 257 2819 2016 Hourly Analysis Program 5.11 Page 8 of 20 Space Design Load Summary for VAV ' Project Name: TUK_SABEY_IGW-C_LEVEL 3RD FL-1_v5_11 Prepared by: HERMANSON COMPANY LLP 09/05/2018 10:34AM TABLE 1.4.A. Component Loads For Space "03-04 Office " In Zone "Z DESIGN COOLING COOLING DATA AT Jun 1700 COOLING OA DB / WB 83.2 °F / 66.4 °F OCCUPIED T -STAT 75.0 °F HEATING DA1 HEATING OA OCCUPIED T - SPACE LOADS Sensible Latent Window & Skylight Solar Loads Wall Transmission Details 72 ft2 (BTU/hr) 4168 (BTU/hr) Roof Transmission 149 ft2 168 Window Transmission Skylight Transmission Door Loads 0 ft2 0 72 ft2 237 0 ft2 0 Floor Transmission Partitions Ceiling 0 ft2 0 0 ft2 0 0 ft2 0 Overhead Lighting Task Lighting 0 ft2 0 Details 72 ft 149 ft 0ft 72 ft 0 ft 0 ft 0 ft 0 ft 0 ft 137 W 302 0 Electric Equipment People OW 0 145 W 477 Infiltration 3 633 615 0 0 0 Miscellaneous Safety Factor 0 0 0 0 » Total Zone Loads 0% / 0% 0 0 0% 5986 615 )ne 1" DESIGN HEATING A AT DES HTG )B/WB 24.0°F/19.2°F STAT 72.0 °F Sensible Latent i (BTU/hr) (BTU/hr) 2 - z 746 - 0 - 1935 - 0 - 0 - 0 - 0 - 0 - 0 - 0 - 0 - - 0 0 55 0 0 0 0 0 2736 0 TABLE 1.4.B. Envelope Loads For Space "03-04 Office' In Zone "Zone 1" COOLING COOLING Area U -Value Shade TRANS SOLAR HEATING W EXPOSURE WALL (ft2) (BTU/(hrft2•°F)) Coeff. (BTU/hr) (BTU/hr) TRANS (BTU/hr) WINDOW 1 149 0.104 72 0.560 0.570 168 237 Hourly Analysis Program 5.11 4168 746 1935 Page 9 of 20 Space Design Load Summary for VAV Project Name: TUK_SABEY_IGW-C_LEVEL 3RD FL -1_v5_11 Prepared by: HERMANSON COMPANY LLP 09/05/2018 10:34AM TABLE 1.5.A. Component Loads For Space "03-05 Office" In Zone "Zone 1" DESIGN COOLING DESIGN HEATING COOLING DATA AT Jun 1700 COOLING OA DB / WB 83.2 °F / 66.4 °F OCCUPIED T -STAT 75.0 °F HEATING DATA AT DES HTG HEATING OA DB f WB 24.0 °F / 19.2 °F OCCUPIED T -STAT 72.0 °F HEATING Sensible Latent Shade Sensible Latent SPACE LOADS Details (BTU/hr) (BTU/hr) Details (BTU/hr) (BTU/hr) Window & Skylight Solar Loads 72 ft2 4168 - 72 ft2 - - Wall Transmission 149 ft2 184 - 149 ft' 818 - Roof Transmission 0 ft2 0 - 0 ft2 0 - Window Transmission 72 ft2 237 - 72 ft2 1935 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 0 ft2 0 - 0 ft2 0 - Floor Transmission 0 ft2 0 - 0 ft2 0 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 212 W 467 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 143 W 471 - 0 0 - People 3 633 615 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 6161 615 - 2753 0 TABLE 1.5.B. Envelope Loads For Space "03-05 Office' In Zone "Zone 1" COOLING COOLING HEATING Area U -Value Shade TRANS SOLAR TRANS (ft2) (BTU/(hr-ft2-°F)) Coeff. (BTU/hr) (BTU/hr) (BTU/hr) W EXPOSURE WALL 149 0.114 - 184 - 818 WINDOW 1 72 0.560 0.570 237 4168 1935 Hourly Analysis Program 5.11 Page 10 of 20 Space Design Load Summary for VAV Project Name: TUK_SABEYIGW-C LEVEL 3RD FL -1_v5_11 Prepared by: HERMANSON COMPANY LLP 09/05/2018 10:34AM •�-- .•..•-,• vv.evpinICII► Lodas ror apace U;5-Ub Conference" In Zone "Zone 1" DESIGN COOLING DESIGN HEATING COOLING DATA AT Jun 1700 COOLING OA DB / WB 83.2 °F / 66.4 °F OCCUPIED T -STAT 75.0 °F HEATING DATA AT DES HTG HEATING OA DB / WB 24.0 °F / 19.2 °F OCCUPIED T -STAT 72.0 °F HEATING Sensible Latent Shade Sensible Latent SPACE LOADS Details (BTU/hr) (BTU/hr) Details (BTU/hr) (BTU/hr) Window & Skylight Solar Loads 100 ft2 5789 - 100 ft2 - (BTU/hr) Wall Transmission 264 ft' 336 - 264 ft2 1449 Roof Transmission 0 ft2 0 - 0 ft' 0 5789 Window Transmission 100 ft2 329 - 100 ft2 2688 Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 0 ft2 0 - 0 ft2 0 Floor Transmission 0 ft2 0 - 0 ft2 0 Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 390 W 859 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 609 W 2005 - 0 0 People 16 3376 3280 0 0 0 Infiltration - 0 0- 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 12694 3280 - 4137 0 --- ....•.-. �..1rwI a+Nc iudus ror apace --Us-Ub conference" In Zone "Zone 1" COOLING COOLING HEATING Area U -Value Shade TRANS SOLAR TRANS (ft2) (BTU/(hr•ft2•°F)) Coeff. (BTU/hr) (BTU/hr) W EXPOSURE (BTU/hr) WALL 264 0.114 - 336 1449 WINDOW 1 100 0.560 0.570 329 5789 2688 Hourly Analysis Program 5.11 Page 11 of 20 Space Design Load Summary for VAV Project Name: TUK_SABEY_IGW-C_LEVEL 3RD FL -1_v5_11 Prepared by: HERMANSON COMPANY LLP 09/05/2018 10:34AM TABLE 1.7.A. Component Loads For Space "03-07 Server Room" In Zone "Zone 1" DESIGN COOLING DESIGN HEATING COOLING DATA AT Jun 1700 COOLING OA DB / WB 83.2 °F / 66.4 °F OCCUPIED T -STAT 75.0 °F HEATING DATA AT DES HTG HEATING OA DB / WB 24.0 °F / 19.2 °F OCCUPIED T -STAT 72.0 °F HEATING Sensible Latent Shade Sensible Latent SPACE LOADS Details (BTU/hr) (BTU/hr) Details (BTU/hr) (BTU/hr) Window & Skylight Solar Loads 50 ft2 2895 - 50 ft2 - - Wall Transmission 80 ft2 95 - 80 ft2 439 - Roof Transmission 0 ft2 0 - 0 ft2 0 - Window Transmission 50 ft2 165 - 50 ft2 1344 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 0 ft2 0 - 0 ft2 0 - Floor Transmission 0 ft2 0 - 0 ft2 0 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 96 W 211 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 400 W 1317 - 0 0 - People 0 0 0 0 0 0 Infiltration - 0 0 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 4682 0 - 1783 0 TABLE 1.7.B. Envelope Loads For Space "03-07 Server Room" In Zone "Zone 1" COOLING COOLING HEATING Area U -Value Shade TRANS SOLAR TRANS (ft2) (BTU/(hr•ft2•°F)) Coeff. (BTU/hr) (BTU/hr) (BTU/hr) W EXPOSURE WALL 80 0.114 - 95 - 439 WINDOW 1 50 0.560 0.570 165 2895 1344 Hourly Analysis Program 5.11 Page 12 of 20 Space Design Load Summary for VAV Project Name: TUK_SABEY_IGW-C_LEVEL 3RD FL -1_v5_11 Prepared by: HERMANSON COMPANY LLP 09/05/2018 10:34AM TABLE 1.8.A. Component Loads For Space "03-08 Copier Room" In Zone "Zone 1" DESIGN COOLING DESIGN HEATING COOLING DATA AT Jun 1700 COOLING OA DB / WB 83.2 °F / 66.4 °F OCCUPIED T -STAT 75.0 °F HEATING DATA AT DES HTG HEATING OA DB / WB 24.0 °F / 19.2 °F OCCUPIED T -STAT 72.0 °F HEATING Sensible Latent Shade Sensible Latent SPACE LOADS Details (BTU/hr) (BTU/hr) Details (BTU/hr) (BTU/hr) Window & Skylight Solar Loads 125 ft2 7236 - 125 ft2 - - Wall Transmission 265 ft2 329 - 265 ft2 1455 - Roof Transmission 0 ft2 0 - 0 ft2 0 - Window Transmission 125 ft2 412 - 125 ft2 3360 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 0 ft2 0 - 0 ft2 0 - Floor Transmission 363 ft2 854 - 363 ft2 4269 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 349 W 768 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 1850 W 6090 - 0 0 - People 3 633 615 0 0 0 Infiltration - 0 0- 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 16322 615 - 9083 0 TABLE 1.8.B. Envelope Loads For Space "03-08 Copier Room" In Zone "Zone 1" COOLING COOLING HEATING Area U -Value Shade TRANS SOLAR TRANS (ft2) (BTU/(hrft2•°F)) Coeff. (BTU/hr) (BTU/hr) (BTU/hr) W EXPOSURE WALL 265 0.114 - 329 - 1455 WINDOW 1 125 0.560 0.570 412 7236 3360 Hourly Analysis Program 5.11 Page 13 of 20 Space Design Load Summary for VAV Project Name: TUK_SABEY_IGW-C_LEVEL 3RD FL -1_v5_11 Prepared by: HERMANSON COMPANY LLP 09/05/2018 10:34AM TABLE 1.9.A. Component Loads For Space "03-09 Break Rm-Kitchen" In Zone '"Zone 1" DESIGN COOLING DESIGN HEATING COOLING DATA AT Jun 1700 COOLING OA DB / WB 83.2 °F / 66.4 °F OCCUPIED T -STAT 75.0 °F HEATING DATA AT DES HTG HEATING OA DB I WB 24.0 °F / 19.2 °F OCCUPIED T -STAT 72.0 °F HEATING Sensible Latent Shade Sensible Latent SPACE LOADS Details (BTU/hr) (BTU/hr) Details (BTUIhr) (BTU/hr) Window & Skylight Solar Loads 50 ft2 2895 - 50 ft2 - - Wall Transmission 119 ft2 150 - 119 ft2 653 - Roof Transmission 0 ft2 0 - 0 ft2 0 - Window Transmission 50 ft2 165 - 50 ft2 1344 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 0 ft2 0 - 0 ft2 0 - Floor Transmission 0 ft2 0 - 0 ft2 0 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 355 W 780 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 550 W 1811 - 0 0 - People 10 2110 2050 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 7910 2050 - 1997 0 TABLE 1.9.B. Envelope Loads For Space "03-09 Break Rm-Kitchen" In Zone "Zone 1" COOLING COOLING HEATING Area U -Value Shade TRANS SOLAR TRANS (ft2) (BTU/(hr•ft2•°F)) Coeff. (BTU/hr) (BTU/hr) (BTU/hr) W EXPOSURE WALL 119 0.114 - 150 - 653 WINDOW 1 50 0.560 0.570 165 2895 1344 Hourly Analysis Program 5.11 Page 14 of 20 Space Design Load Summary for VAV Project Name: TUK_SABEY_IGW-C LEVEL 3RD FL -12v5_11 Prepared by: HERMANSON COMPANY LLP 09/05/2018 10:34AM TABLE 1.10.A. Component Loads For Space "03-10 Reception" In Zone "Zone 1" DESIGN COOLING DESIGN HEATING COOLING DATA AT Jan 2100 COOLING OA DB / WB 59.2 °F / 52.5 °F OCCUPIED T -STAT 75.0 °F HEATING DATA AT DES HTG HEATING OA DB / WB 24.0 °F / 19.2 °F OCCUPIED T -STAT 72.0 °F HEATING Sensible Latent Shade Sensible Latent SPACE LOADS Details (BTU/hr) (BTU/hr) Details (BTU/hr) (BTU/hr) Window & Skylight Solar Loads 0 ft2 0 - 0 ft2 - - Wall Transmission 0 ft2 0 - 0 ft2 0 - Roof Transmission 0 ft2 0 - 0 ft2 0 - Window Transmission 0 ft2 0 - 0 ft2 0 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 0 ft2 0 - 0 ft2 0 - Floor Transmission 0 ft2 0 - 0 ft2 0 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 557 W 1252 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 145 W 481 - 0 0 - People 4 876 820 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 2609 820 - 0 0 TABLE 1.10.B. Envelope Loads For Space "03-10 Reception" In Zone "Zone 1" COOLING COOLING HEATING Area U -Value Shade TRANS SOLAR TRANS (ft2) (BTU/(hr•ft2•°F)) Coeff. (BTU/hr) (BTU/hr) (BTU/hr) Hourly Analysis Program 5.11 Page 15 of 20 Space Design Load Summary for VAV Project Name: TUK_SABEY_IGW-C_LEVEL 3RD FL -1_v5_11 Prepared by: HERMANSON COMPANY LLP 09/05/2018 10:34AM TABLE 1.11.A. Component Loads For Space "03-11 Office" In Zone "Zone 1" DESIGN COOLING DESIGN HEATING COOLING DATA AT Jan 2100 COOLING OA DB / WB 59.2 °F / 52.5 °F OCCUPIED T -STAT 75.0 °F HEATING DATA AT DES HTG HEATING OA DB / WB 24.0 °F / 19.2 °F OCCUPIED T -STAT 72.0 °F HEATING Sensible Latent Shade Sensible Latent SPACE LOADS Details (BTU/hr) (BTU/hr) Details (BTU/hr) (BTU/hr) Window & Skylight Solar Loads 0 ft2 0 - 0 ft2 - - Wall Transmission 0 ft2 0 - 0 ft2 0 - Roof Transmission 0 ft2 0 - 0 ft2 0 - Window Transmission 0 ft2 0 - 0 ft2 0 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 0 ft2 0 - 0 ft2 0 - Floor Transmission 0 ft' 0 - 0 ft2 0 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 195 W 438 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 145 W 481 - 0 0 - People 3 657 615 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous- 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 1577 615 - 0 0 TABLE 1.11.B. Envelope Loads For Space "03-11 Office" In Zone "Zone V COOLING COOLING HEATING Area U -Value Shade TRANS SOLAR TRANS (ft2) (BTU/(hrft2•°F)) Coeff. (BTU/hr) (BTU/hr) (BTU/hr) Hourly Analysis Program 5.11 Page 16 of 20 Space Design Load Summary for VAV 1 Project Name: TUK_SABEY_IGW-C_LEVEL 3RD FL -1_v5_11 Prepared by: HERMANSON COMPANY LLP 09/05/2018 10:34AM TABLE 1.12.A. Component Loads For Space "03-12 Storage" In Zone "Zone 1" DESIGN COOLING DESIGN HEATING COOLING COOLING DATA AT Jan 2200 COOLING OA DB / WB 57.4 °F / 51.8 °F OCCUPIED T -STAT 75.0 °F HEATING DATA AT DES HTG HEATING OA DB / WB 24.0 °F / 19.2 °F OCCUPIED T -STAT 72.0 °F Area Sensible Latent TRANS Sensible Latent SPACE LOADS Details (BTU/hr) (BTU/hr) Details (BTU/hr) (BTU/hr) Window & Skylight Solar Loads 0 ft2 0 - 0 ft2 - - Wall Transmission 0 ft2 0 - 0 ft2 0 - Roof Transmission 0 ft2 0 - 0 ft2 0 - Window Transmission 0 ft2 0 - 0 ft2 0 - Skylight Transmission 0 ft2 0 - 0 ft2 0 Door Loads 0 ft2 0 - 0 ft2 0 Floor Transmission 0 ft2 0 - 0 ft2 0 - Partitions 0 ft2 0 - 0 ft2 0 Ceiling 0 ft' 0 - 0 ft2 0 - Overhead Lighting 309 W 696 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 0 W 0 - 0 0 - People 0 0 0 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 00 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 696 0 - 0 0 TABLE 1.12.B. Envelope Loads For Space "03-12 Stora e" In Zone "Zone 1" COOLING COOLING HEATING Area U -Value Shade TRANS SOLAR TRANS (ft2) (BTU/(hr•ft2•°F)) Coeff. (BTU/hr) (BTU/hr) (BTU/hr) Hourly Analysis Program 5.11 Page 17 of 20 Space Design Load Summary for VAV Project Name: TUK_SABEY_IGW-C_LEVEL 3RD FL -1_v5_11 Prepared by: HERMANSON COMPANY LLP 09/05/2018 10:34AM TABLE 1.13.A. Component Loads For Space "03-13 Open Office -Hall' In Zone "Zone 1" DESIGN COOLING DESIGN HEATING COOLING DATA AT Jan 2100 COOLING OA DB / WB 59.2 °F / 52.5 °F OCCUPIED T -STAT 75.0 °F HEATING DATA AT DES HTG HEATING OA DB / WB 24.0 °F / 19.2 °F OCCUPIED T -STAT 72.0 °F HEATING Sensible Latent Shade Sensible Latent SPACE LOADS Details (BTU/hr) (BTU/hr) Details (BTU/hr) (BTU/hr) Window & Skylight Solar Loads 0 ft2 0 - 0 ft' - - Wall Transmission 0 ft2 0 - 0 ft2 0 - Roof Transmission 0 ft2 0 - 0 ft2 0 - Window Transmission 0 ft2 0 - 0 ft2 0 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 0 ft2 0 - 0 ft2 0 - Floor Transmission 0 ft2 0 - 0 ft2 0 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 853 W 1914 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 290 W 963 - 0 0 - People 4 876 820 0 0 0 Infiltration - 0 0 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 3753 820 - 0 0 TABLE 1.13.B. Envelope Loads For Space "03-13 O en Office -Hall" In Zone "Zone 1" COOLING COOLING HEATING Area U -Value Shade TRANS SOLAR TRANS (ft2) (BTU/(hrft2•°F)) Coeff. (BTU/hr) (BTU/hr) (BTU/hr) Hourly Analysis Program 5.11 Page 18 of 20 System Psychrometrics for VAV Project Name: TUK_SABEY_IGW-C_LEVEL 3RD FL -1_v5_11 Prepared by: HERMANSON COMPANY LLP 09/05/2018 10:34AM June DESIGN COOLING DAY, 1600 TABLE 1: SYSTEM DATA Component Location Dry -Bulb Temp (°F) Specific Humidity (Ib/Ib) Airflow (CFM) CO2 Level (ppm) Sensible Heat (BTU/hr) Latent Heat (BTU/hr) Ventilation Air Inlet 84.5 0.01025 926 400 7502 9533 Vent - Retum Mixing Outlet 78.6 0.00858 3889 955 - - Central Cooling Coil Outlet 51.3 0.00738 3889 955 113073 21630 Supply Fan Outlet 54.4 0.00738 3889 955 12972 - Cold Supply Duct Outlet 55.0 0.00738 3811 955 - - Zone Air - 76.0 0.00806 3811 1132 85153 12095 Return Plenum Outlet 77.3 0.00806 3811 1132 5094 - Duct Leakage Air Outlet 54.4 0.00738 78 955 - - Retum Duct Outlet 76.8 0.00805 3889 1129 - - Air Density x Heat Capacity x Conversion Factor: At sea level = 1.080; At site altitude = 1.063 BTU/(hr-CFM-F) Air Density x Heat of Vaporization x Conversion Factor: At sea level = 4746.6; At site altitude = 4670.1 BTU/(hr-CFM) Site Altitude = 449.0 ft TABLE 2: ZONE DATA Zone Name Zone Sensible Load (BTU/hr) T -stat Mode Zone Cond (BTU/hr) Zone Temp (°F) Zone Airflow (CFM) CO2 Level (ppm) Terminal Heating Coil (BTU/hr) Zone Heating Unit (BTU/hr) Zone 1 78418 Cooling 85153 76.0 3811 1132 0 0 Hourly Analysis Program 5.11 Page 19 of 20 System Psychrometrics for VAV Project Name: TUK_SABEY_IGW-C_LEVEL 3RD FL -1_v5_11 Prepared by: HERMANSON COMPANY LLP 09/05/2018 10:34AM WINTER DESIGN HEATING TABLE 1: SYSTEM DATA T Component Location Dry -Bulb Temp (°F) Specific Humidity (Ib/Ib) Airflow (CFM) CO2 Level (ppm) Sensible Heat (BTU/hr) Latent Heat (BTU/hr) Ventilation Air Inlet 24.0 0.00103 926 400 -44982 0 Vent - Return Mixing Outlet 33.4 0.00103 1167 401 - - Central Cooling Coil Outlet 33.4 0.00103 1167 401 0 0 Supply Fan Outlet 34.8 0.00103 1167 401 1686 - Cold Supply Duct Outlet 33.8 0.00103 1143 401 - - Zone Air - 70.4 0.00103 1143 403 -37324 0 Return Plenum Outlet 70.4 0.00103 1143 403 0 - Duct Leakage Air Outlet 34.8 0.00103 23 401 - - Return Duct Outlet 69.7 0.00103 1167 403 - - Air Density x Heat Capacity x Conversion Factor: At sea level = 1.080; At site altitude = 1.063 BTU/(hr-CFM-F) Air Density x Heat of Vaporization x Conversion Factor: At sea level = 4746.6; At site altitude = 4670.1 BTU/(hr-CFM) Site Altitude = 449.0 ft TABLE 2: ZONE DATA Zone Name Zone Sensible Load (BTU/hr) T -stat Mode Zone Cond (BTU/hr) Zone Temp (°F) Zone Airflow (CFM) CO2 Level (ppm) Terminal Heating Coil (BTU/hr) Zone Heating Unit (BTU/hr) Zone 1 -39597 Heating -37324 70.4 3811 403 80332 0 Hourly Analysis Program 5.11 Page 20 of 20 .PERMIT COORD COPY 0 PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M18-0121 DATE: 09/24/18 PROJECT NAME: SEATTLE CHILDRENS SITE ADDRESS: 12101 TUKWILA INT'L BLVD X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: Building Division Public Works Fire Prevention Structural 19u6\1(6 Planning Division ❑ Permit Coordinator PRELIMINARY REVIEW: DATE: 09/25M3_ Not Applicable ri Structural Review Required (no approval/review required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved DUE DATE: 10/238 ❑ Approved with Conditions ❑ Corrections Required ❑ Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping ❑ PW 0 Staff Initials: 12/18/2013 HERMANSON COMPANY LLP Washington State Department of Labor & Industries Horne Espanol Contact Safety & Health Claims & Insurance Search L&I Page 1 of 3 J A -Z Index Help My L &.t Workplace Rights Trades & Licensing HERMANSON COMPANY LLP Owner or tradesperson Principals NICOLAISEN, KNUT H, PARTNER/MEMBER BROCK, DANIEL L, PARTNER/MEMBER FOX, DEAN M, PARTNER/MEMBER HENGEL, STEPHEN A, PARTNER/MEMBER DYCKMAN, KENNETH A, PARTNER/MEMBER ROBINETT, PAUL J, PARTNER/MEMBER HERMANSON, RICHARD L, PARTNER/MEMBER ALMON, KEVIN, PARTNER/MEMBER (End: 08/05/2010) MACDONALD, JAMES, PARTNER/MEMBER (End: 08/05/2010) Doing business as HERMANSON COMPANY LLP WA UBI No. 602 004 844 1221 2ND AVE N KENT, WA 98032-2945 206-575-9700 KING County Business type Limited Liability Partnership Governing persons CORP HERMANSON LLC HERMANSON GROUP; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. ......_.............._......................._.... Meets current requirements. License specialties GENERAL License no. HERMACLOO5BJ Effective — expiration 01/11/2000— 08/25/2020 Bond WESTERN SURETY CO Bond account no. 929381801 $12,000.00 Received by L&I Effective date 12/01/2005 01/01/2006 Expiration date Until Canceled Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602004844&LIC=HERMACL005BJ&SAW= 10/3/2018 HERMANSON COMPANY LLP Page 2 of 3 Insurance Transportation lits Co Policy no. 6043050846 $1,000,000.00 Received by L&I Effective date 08/16/2018 08/21/2018 Expiration date 08/21/2019 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against t:ie bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&l tax debts E.re recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license vioiaticas during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID 409,648-01 Doing business as HERMANSON COMPANY LLP Estimated workers reported Quarter 2 of Year 2018 "Greater than 100 Workers" L&I account contact T4 / TERRI MADIS JN (360)902-4654 - Email: KIRT235@Ini.wa.gov Account is current. Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not ai:owed to bid No debarments have been issued against this contractor. Workplace safety and health Check for any past afety and health violations found on jobsites this business was responsible for. Inspection results date 05/22/2018 Violations Inspection no. 317948819 Location 1221 2nd Ave N Kent, WA 98032 Inspection results date 03/05/2018 Inspection no. 317948149 Location 635 Park Ave N Renton, WA 980::7 Inspection results date 02/23/2016 Inspection no. 317939295 No violations No violations Help us improve https://secure.lni. wa.gov/verify/Detail.aspx?UBI=602004844&LIC=HERMACL005BJ&SAW= 10/3/2018