HomeMy WebLinkAboutPermit M18-0124 - SCHOFIELD LP / SHELL - ROOFTOP UNIT, VENTILATOR, ELECTRIC DUCT HEATER, ETCSCHOFIELD SHELL TI 16915 SOUTHCENTER PKWY EXPIRED 12/04/19 M18-0124 Parcel No: Address: i _1 \ City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 2623049011 Permit Number: M18-0124 16915 SOUTHCENTER PKWY Project Name: SCHOFIELD SHELL TI Issue Date: 10/17/2018 Permit Expires On: 4/15/2019 Owner: Name: Address: Contact Person: Name: Address: SCHOFIELD LP 911 MAIN STREET STE 1500 , KANSAS CITY, WA, 64105 ALEX BURKHART 727 S KENYON ST , SEATTLE, WA, 98108 Contractor: Name: EVERGREEN REFRIGERATION LLC (CONST) Address: 727 S KENYON ST , SEATTLE, WA, 98108 License No: EVERGRL954R2 Lender: Name: Address: Phone: (206) 763-1744 Phone: (206) 763-1744 Expiration Date: 1/6/2020 DESCRIPTION OF WORK: INSTALLATION OF ONE (1) ROOFTOP UNIT, ONE (1) ENERGY RECOVERY VENTILLATOR, ONE (1) ELECTRIC DUCT HEATER, TWO (2) ROOF HOODS, DUCTWORK, AND GRILLES/DIFFUSERS. Valuation of Work: $0.00 Type of Work: NEW Fuel type: ELECT Fees Collected: $597.26 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Date: /0— 1 7-4 E I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the nditions attached to this permit. Signature: 2 Date: M Print Name: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***MECHANICAL PERMIT CONDITIONS*** 2: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 3: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0701 ROUGH -IN MECHANICAL / \ CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov r 1 Mechanical Permit No. Project No. Date Application Accepted: Date Application Expires: 01'2-14- (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address: 16915 Southcenter Pkwy King Co Assessor's Tax No.: 2623049011 Suite Number: N/A Floor: Tenant Name: N/A SCl1b ie lct S" L< [ J PROPERTY OWNER Name: Alex Burkhart Name: Schofield LP City: Seattle State: WA Zip: 98108 Address: 911 Main St., Suite 1500 Email: alexb@evergreenhvac.com City: Kansas City State: MO Zip: 64105 CONTACT PERSON — person receiving all project communication Name: Alex Burkhart Address: 727 South Kenyon St. City: Seattle State: WA Zip: 98108 Phone: (206) 763-1744 Fax: (206) 763-2389 Email: alexb@evergreenhvac.com New Tenant: Yes ❑ ..No MECHANICAL CONTRACTOR INFORMATION Company Name: Evergreen Refrigeration Address: 727 South Kenyon St. City: Seattle State: WA Zip: 98108 Phone: (206) 763-1744 Fax: (206) 763-2389 Contr Reg No.: EVERGRL954R2 Exp Date: 01/06/2018 Tukwila Business License No.: BUS -0992877 Valuation of project (contractor's bid price): $ Describe the scope of work in detail: Installation of one (1) rooftop unit, one (1) energy recovery ventilator, one (1) electric duct heater, two (2) roof hoods, ductwork, and grilles/diffusers. 29,874 Use: Residential: New ❑ Replacement ❑ Commercial: New Replacement ❑ Fuel Type: Electric Gas ❑ Other: H:\Applications\Forms-Applications On Line \2016 ApplicationsVvtechanical Permit Application Revised I-4-16.docx Revised: January 2016 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Residential, Nighttime Furnace >100k btu 18 Floor furnace 55 dB(A) Suspended/wall/floor mounted heater 1 Appliance vent 1 Repair or addition to heat/refrig/cooling system 2 Air handling unit 65 dB(A) <10,000 cfm 1 Unit Type Qty Air handling unit Residential, Nighttime >10,000 cfm 18 Evaporator cooler 55 dB(A) Ventilation fan connected to single duct 57 dB(A) Ventilation system 1 Hood and duct 2 Incinerator — domestic 65 dB(A) Incinerator — comm/industrial 60 dB(A) Unit Type Qty Fire damper Residential, Nighttime Diffuser 18 Thermostat 55 dB(A) Wood/gas stove 57 dB(A) Emergency generator Commercial Other mechanical equipment 2 60 dB(A) 65 dB(A) Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-10PM, Monday through Friday and 8AM-10PM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: • Warning devices; • Construction and property maintenance during the daytime hours (7am-lOpm); • Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). 1 HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Date: Print Name: Alex Burkhart Day Telephone: (206) 763-1744 Mailing Address: 727 South Kenyon St. Seattle WA 98108 CityState Zip H.\Applications\Forms-Applications On Line\2016 Applications\Ivlechanical Permit Application Revised 1-4-16.docx Revised January 2016 bh Page 2 of 2 DESCRIPTIONS ACCOUNT PermitTRAK I QUANTITY {;" PAID $666.88 EL18-0822 Address: 16915 SOUTHCENTER PKWY Apn: 2623049011 $69.62 ELECTRICAL $66.30 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $66.30 TECHNOLOGY FEE $3.32 TECHNOLOGY FEE R000.322.900.04.00 0.00 Y: $3.32 M18-0124 Address: 16915 SOUTHCENTER PKWY Apn: 2623049011 $597.26 MECHANICAL $574.29 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $426.28 PLAN CHECK FEE R000.322.102.00.00 0.00 $114.86 TECHNOLOGY FEE $22.97 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R15481 R000.322.900.04.00 0.00 . $22.97 $666.88 Date Paid: Wednesday, September 26, 2018 Paid By: EVERGREEN REFRIGERATION Pay Method: CHECK 09635 Printed: Wednesday, September 26, 2018 9:55 1 of 1 AM SYSTEMS INSPECTION NO. INSPECTION RECORD Retain a copy with permit J1.[g012' PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pro t Tye t - triiih4L C CSG 51i (= --TT Address: i 0 /5 ...5514.41tGagr Date Called: Special Instructions: t Date Wanted:a.m. &,- 7- 202 p.m. Requ kt Phone 6.7 rS)3' Approved per applicable codes. Corrections required prior to approval. COMMENTS: Ir If A.1P9T4 a 4s,7� Inspector: ( j c _/ tx/CO__ Date: 7 I ! REINSPECTION FEE REQUIRED. Prior to next inspection, fee must lie paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit CTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: o -,J Addreesis: 40 %t t spe iaons: Q Type of Inspection: 54i�f-e'f L Date Called: Date Wanted: -10-►9 p.m. R nester. J- n aLce WA -LS Phone No: 2,53-651.1SZ3 0 Approved per applicable codes. Corrections requir COMMENTS: ` `Kt%) pproval. Aje.tol iteLee)i-vc //c/a, giftN 44/ }Lb ✓ j�i2v 1A l rte. 6 ✓e- ift-cef(iw ivde-vt- erff-ykL,_ Rov\st Nd" uLodAlei ll - Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit /f1 612/74 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: 140 REI/0 SAS Ti Type of Inspection: PPE /A ".1 Pift/ arrive % Addre s: /to? /S ;X}sries,s-rroz- 844( Date Calle°': Special Instructions: / Date Wanted: ,, eern., //-a- p.m. Requester: Phone No: pCorrApproved per applicable codes. ections required prior to approval. CLJ COMMENTS: / ��✓l�1 /ii&JiA-'ka✓ Me -r -?,t Pe-°/eSb Inspector Date: REINSPECTION FEE REQUIRED. Prior to next inspeEtion, fee 'must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INS CTION NO. INSPECTION RECORD Retain a copy with permit nig Dag PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Cli d'F !ELS fi L.----11 Type of Inspection: 0 Il Pia Address: ilo9 i S 6a' 1Cca 2- i4 Date Called: Special Instructions: Date Wanted:Th ij_ /9-zag m. Requester: Phone No: 0 Approved per applicable codes. Corrections required prior to approval. COMMENTS: aill0 IA° WO Gr*I'd.t) ccf-- <MA - of 0111 A AM Veil' r Jo OD 1) letyc, Parceinled did( Nta- eviver* GAP /!i/,S InspectoSan Date/ 1. 20/E( REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. M . 12L/ CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Plojec � f fiz e of inspection: , i Address: 169ift)t Att/Itsepkr Pftudi 4 Date C ed: Special Instructions: Date Wanted: / I - 15 a.m. p.m. Requ ster: MI).6.i. 74,347 ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: /o(gw T pi -A.005 Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. a INSPECTION NO. INSPECTION RECORD Retain a copy with permit 1118-0121 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: TX T of Inspection: ._t) HeeltAll 4.1c44 Add e-� L '�- r�"'„ Date C ed: G. a. m. p..m. Special Instructions: •1 f rtf •2 geor i • 1 E Kai . CiAtivortAfilpio 10 1 &et -Owl Meijer Date Wanted: /0-23-2018 Requester: x- PA -0-1 Phone No: Approved per applicable codes. IjCorrections r • royal. COMMENTS: 4 J �rtStt(o 4,arl _� �y- �q )4't-2(1/1 RQ ( I .P i x- PA -0-1 ... D(kr 1-S "Di _ ab f�j //lye ioL51,1a bil&I- r 0 f pv o,r2� R_C A cofc 110 i 11,04, ( ',•ed a 4- 14-1\ c i-t‘yri t . f-0 Tr) /Pt, s ulcd , 19#11-11,(1_,J ,� V L t Gj kteader / S ft (1-7l (' 7) i5 nfl* P1 ltalott gee., Roa Mr Inspector Date:/ 0/23 /zo/ ( REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Project Summary PROJ-SUM 2015 WSEC Compliance Forms for Commercial Buildings including R2, R3, & R4 over 3 stories and all R1 Revised Jun 2016 General Info This PROJ-SUM form shall be provided as a cover sheet for all compliance form submittals. Project Title matches projects plans title block. Project Title: 1 - This title will copy onto other forms Date 9/26/2018 Project Street Address: 16915 Southcenter Pkwy For Building Department Use . .� J1 `- t Project City, County, Zip: Tukwila, WA 98188 Project Owner or Rep: Schofield LP Jurisdiction: City of Tukwila Project Description Select all that apply to the scope of project. Select Addition + Existing or Alteration + Existing if the existing building will be combined with the addition or alteration to demonstrate compliance per Section C502.1 or C503.1. New Construction ❑ New Building Existing Building and Additions ❑ Building Addition Retrofit ❑ Alteration + Existing of Occupancy ❑ Historic Building Scope - Select all that apply ❑ Building Envelope ❑ Addition + Existing ❑ Change in Space Conditioning ' Alteration ❑ Change Building Elements ❑ All ❑ Service Hot -' Mechanical Systems Water Systems 1 Lighting Systems • Electrical Systems Occupancy Type 1� Y yP Q All Commercial Q Group R - R2, R3, & R4 Q over 3 stories and all R1 Mixed Use - Building is greater than three stories above grade and it has both Commercial and Group R occupancies. Mixed Occupancy - Building is three stories or less above grade and it has both Commerical and Group R2, R3 or R4 occupancies. Select All Commercial to document compliance for the commercial areas of the building. The residential spaces shall comply with the WSEC Residential Provisions. Space Conditioning Categories Select all that apply to the scope of project ❑ Semi-heated2 ❑ Refrigerated Warehouse, Walk-in Cooler/Freezer, Space Category3 Refrigerated Display Case' 1 Fully Conditioned ❑ Low Energy Eligible Low Energy Spaces ❑ Unconditioned ❑ Low energy heating/cooling capacity ❑ Wireless service ❑ Greenhouse4 ❑ Equipment building equipment shelter Floor Area and Stories Floors Above Grade Building Gross Conditioned Floor Area Project Gross Conditioned Floor Area Q Prescriptive C, Total Building Performance Prescriptive - Projects complying prescriptively shall demonstrate compliance with all applicable mandatory and prescriptve requirements of this code. Refer to C401.2, Item 1 for more information. Compliance forms General Compliance to include with a Prescriptive submittal: All applicable ENV, LTG, MECH and C406. Path Total Building Performance - Projects complying via total building performance (TBP) shall include a summary of results from a whole building energy model per Section C407 and shall demonstrate compliance with all applicable mandatory provisions in this Code. Refer to Section C401.2, Item 2 for more information. Compliance forms to include with a TPB submital: PROJ-SUM, C406 -SUM & C406 -DETAIL, ENV -CHK, ,1 a...,,,__LTG-EXT, LTG -CHK, and all MECH forms (except MECH-ECONO). ODE COMPLIANCE APPROVED OCT 10 2018 City BUILDINGof Tukwila DIVISION rfcucvvmu CITY OF TUKWILA SFP 2 2018 puthin CENTER M%� OILM 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 Mechanical Summary MECH-SUM Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised January 2017 2015 Washington State Energy Code Compliance Project Information Project Title: Schofield Shell Date 9/26/2018 Applicant Information. Provide contact information for individual who can respond to inquiries about compliance form information provided. For Building Dept. Use Company Name: Evergreen Refrigeration Company Address: 727 South Kenyon St. Seattle, WA 98108 Applicant Name: Alex Burkhart Applicant Phone: 206-763-1744 ext. 247 Project Description Briefly describe mechanical systems in the text box provided ❑ Total Bldg Performance (TBP) This path includes all mandatory provisions per C401.2 Option 2. MECH-SUM, MECH-CHK, and C407 Energy Analysis forms required. ofit ❑ No System Changes duct heater, two (2) roof II New Building • Building Addition 0 Tenant Improvement ❑ System Ret Installation of one (1) rooftop unit, one (1) energy recovery ventilator, one (1) electric hoods, ductwork, and grilles/diffusers. Design Load Calculations ❑ Load calculation summary ❑ MECH-LOAD-CALC Form Provide design load calculations for all mechanical systems and equipment serving the building heating, cooling or ventilating needs. If a load calculation summary is provided with the permit documents that includes all applicable compliance information then the MECH-LOAD-CALC form is not required. Mechanical Schedules 0 Mechanical Plans ❑ MECH-EQ Forms (TBD) Indicate location of equipment compliance information. If provided on plans then MECH-EQ forms are not required, however, include on plans all applicable compliance information listed in MECH-EQ tables. Dedicated Outdoor Air System Requirements and High Efficiency VAV Alternate fire station occupancies) air in a manner that does heating or cooling is required. Exception 1) of DOAS (C403.6, Exception library or fire station) C402.4.1.4 with 100% of El DOAS is required per C403.6 effective July 1, 2017 (office, retail, education, library and All occupied, conditioned areas shall be served by a DOAS that delivers required ventilation not require space conditioning fan operation. Space conditioning fans cycled off when no ❑ Ventilation provided via natural ventilation per 2015 IMC in lieu of DOAS (C403.6, ❑ Ventilation and space conditioning provided by a HEVAV system per C403.7 in lieu ❑ DOAS included in project, although not required (occupancy not office, retail, education, ❑ DOAS related allowances included in project: ❑ Prescriptive vertical fenestration maximum area allowance increased to 40% per conditioned floor area in building served by DOAS. ❑ Exception to air economizer per C403.3 Exception 1, include MECH-ECONO form. Fan Power Q Project includes HVAC air distribution systems that provide heating and/or cooling If yes, provide a MECH-FANSYS -SUM form. ❑ For one or more systems, the total fan motor nameplate hp of all fans in HVAC system exceeds 5hp. If yes, provide a seperate MECH-FANSYS form for each HVAC system exceeding the 5 horsepower threshold. Refer to Section C403.2.11 and MECH-FANSYS-DOC for requirements and exceptions. HVAC Hydronic Systems 1 Hydronic chilled water ❑ Water -loop heat pump Q No hydronic systems ❑ Hydronic heating water ❑ Geothermal C406 Additional Efficiency Options - Mechanical ❑ C406.2 More efficient HVAC equipment and fan systems Requires 90% of heating and cooling capacity to be equipment listed in tables C403.2.3(1)-(9) or air -to -water heat pumps and heat recovery chillers. All equipment listed in tables C403.2.3(1)-(7) must be 15% more efficient than minimum requirements. All stand alone supply, return, and exhaust fans over 1 hp must have FEQ _> 71 and must be selected within 10% of maximum total or static pressure. ❑ C406.6 Dedicated outdoor air system (DOAS) Requires 90% of conditioned floor area to be served by a DOAS per C403.6 that delivers required ventilation air in a manner that does not require space conditioning fan operation. ❑ C406.7 Reduced energy in service water heating Requires 90% of floor area be in occupancy types listed in C406.7.1 and that 60% of annual hot water energy use be provided by heat pump, waste heat recovery or solar water -heating systems. 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 Mechanical Summary, pg. 2 MECH-SUM 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised January 2017 Service Water Heating Systems Equipment Type (s) ❑ Hot water heating tank(s) ❑ Instantaneous ❑ Dedicated boiler ❑ Heat exchange from space heat boiler or central hot water/steam Distribution Type (s) ❑ Circulation System ❑ On -demand 1 No service water systems Commissioning Commissioning is required for: ❑Q Mechanical systems per C408.2 ❑ Service water heating systems per C408.4 If required, commissioning shall be performed for all applicable systems regardless of individual equipment capacity. Exceptions to commissioning requirements: ❑ Total output capacity of all mechanical space conditioning systems in the building do not exceed 240,000 Btu/h cooling or 300,000 Btu/h heating. Mechanical systems commissioning not required. ❑ Capacity of largest service water heating system in building does not exceed 200,000 Btu/h. Service water heating systems commissioning not required. Low Energy and Semi -Heated Spaces (Note 6 and 7) Space Type Location in Plan(s) Space(s) Served Area Served, square feet Heating Capacity, Btu/h (Note 4) Cooling Capacity, Btu/h (Note 5) Peak Space Conditioning Capacity, Btu/h-sf Compliance Check Notes Note 4 - Provide total installed heating output capacity of systems serving Low Energy or Semi -Heated space(s) in btuh. Note 5 - Provide total installed cooling capacity of system serving Low Energy space(s) in Btu/h. Not allowed for semi -heated spaces. Enter 0 if no cooling. Note 6 - Refer to Section C402.1.1 Low Energy Building. Intalled peak space conditioning capacity, heating or cooling, may not exceed 3.4 Btu/h`sf. Note 7 - Refer to Section C402.1.1.1 and Semi -Heated Space definition in Chapter 2. Total heating output capacity may not exceed 8 Btu/h'sf. Only systems without electric resistance heating and no cooling are eligible for the wall insulation exception under semi -heated. 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 - Page 1 of 7 Mechanical Permit Plans Checklist MECH-CHK 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised January 2 Project Title: Schofield Shell Date 9/26/2018 The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the Washington State Energy Code, Commercial Provisions. Applicable (yes,no,na) Code Section Code Provision Information Required - Must be in permit documents Location in Documents Building Department Notes Equipment - Sizing, Performance and Type WA C403.1 Exempt process equipment Identify equipment to be used in manufacturing, industrial or commercial processes that do not provide space conditioning; identify provisions applicable to this equipment per C403.1 exception NA C403.2.1 Load calculations Provide load calculations performed per ASHRAE Std 183 or equivalent, using design parameters per C302 and Appendix C; include load adjustments to account for energy recovery NA C403.2.2than Equipment and system sizing Indicate that output capacities of heating and cooling equipment and systems are no greater the smallest available equipment size that exceeds the calculated loads; note exceptions taken Yes C403.2.3 C403.2.3.2 .2.3.2 C403.2.13.1 HVAC equipment performance requirements (efficiency) Provide equipment schedules on plans or complete MECH-EQ forms indicating type, capacity, rated and WSEC minimum efficiencies for all heating and cooling equipment; include supply and OSA cfms and operating hours for all air systems; identify heating and cooling equipment that does not have a corresponding WSEC minimum efficiency (manufacturer rated) M001 N/A C405.8 C403.2.14 Electric motor efficiency List all motors z 1/12 hp (that are not integral to a rated piece of equipment) in the mechanical or electrical equipment schedules on plans; indicate hp, rpm, number of poles and rated efficiency, or exception applied For fractional hp motors (1/12 - 1 hp), indicate whether they are an electronically commutated motor, have rated efficiency of at least 70%, or exception taken N/A C403.2.11.1 Fan power limitation For all HVAC fan systems that provide heating and / or cooling, provide system total nameplate hp in MECH-FANSYS-SUM form For all applicable HVAC systems with total fan motor hp > 5hp, verify fan system motor hp or bhp complies with fan power limits per equations in Table C403.2.11.1(1), provide MECH- FANSYS form for each system WA C403.2.11.2 Motor nameplate hp For all applicable HVAC systems with total fan motor hp > 5hp, indicate fan motors specified are the smallest available motor hp size greater than fan bhp, note exceptions taken N/A C403.2.11.3 Fan efficiency For all applicable HVAC systems with total fan motor hp > 5hp, identify in equipment schedule all fans required to comply with fan efficiency grade and indicate rated FEG is >_ 67, or exception taken; indicate these fans are sized so total efficiency is within 15% of the fan maximum total efficiency N/A C403.2.11.4 Group R occupancy exhaust fan efficacy For all exhaust fans < 400 cfm in Group R occupancies, indicate in equipment schedule the fan flow rate and efficacy (cfm/watt), or exception taken; refer to Table C403.2.11.4 (CE -57) N/A C403.2.13 Variable flow capacity - fans For fan motors z 7.5 hp, indicate method of variable flow control (VSD or equivalent method) in equipment schedule, or exception taken; for equivalent method for an HVAC system refer to HVAC System Controls for additional requirements N/A C403.2.3 Maximum air cooled chiller capacity For chilled water plants and buildings with > 500 tons of cooling capacity, indicate air-cooled chiller capacity is s 100 tons, or exception taken N/A C403.4 Large capacity cooling systems For buildings with >_ 300 tons of cooling capacity, indicate method of multi -stage or variable capacity control (VSD, multiple staged compressors, or max capacity of any single unit < 66% of the total) N/A C403.2.3.1 Non-standard water-cooled centrifugal chillers For water-cooled centrifugal chillers not designed for operation at standard conditions, provide calculations documenting maximum full load and part load rated equipment performance requirements WA C403.2.13.1 C403.4.3.2 Centrifugal fan open -circuit cooling towers For open -circuit centrifugal fan cooling towers with z 1,100 gpm capacity, indicate cooling towers comply with efficiency requirements for axial fan open circuit cooling towers N/A C403.4.2 C403.4.2.5 Large capacity boiler systems For single boilers with > 500,000 Btu/h capacity, indicate multi -stage or modulating bumer For boiler system (single or multiple) with > 1,000,000 Btu/h capacity, indicate tumdown ratio per Table C403.4.2.5 and method (multiple single input boilers, modulating boilers, or combination) N/A C403.2.13 Variable flow capacity - pumps For pump motors >_ 7.5 hp, indicate method of variable flow control (VSD or equivalent method) in equipment schedule, or exception taken; for equivalent method for a hydronic system refer to Hydronic System Controls for additional requirements N/A C403.2.3 Gas and oil -fired forced air furnace and unit heaters For forced air fumaces with capacity >_ 225,000 Btu/h and all unit heaters, indicate in equipment schedule intermittent ignition or IID, flue or draft damper, and rated jacket loss N/A C403.2.4.8 Combustion heating equipment For combustion heating equipment with output capacity > 225,000 Btu/h, indicate modulating or staged combustion control WA C403.2.3.3 Packaged electric heating / cooling equipment Verify at packaged electric equipment with > 6,000 Btu/h cooling capacity and any amount of heating is a heat pump; include in equipment schedules N/A C403.2.12 Heating outside a building Indicate systems providing heating in non -enclosed outdoor occupied spaces are radiant systems; refer to HVAC System Controls for additional requirements N/A C403.2.7.1 Kitchen exhaust hoods Indicate on plans the type, duty and exhaust air rate of each kitchen hood, refer to HVAC System Controls for additional requirements Yes C403.2.4.3 Outdoor supply air, exhaust and relief dampers Indicate locations of OSA intake, and exhaust and relief outlet dampers on plans; indicate whether dampers are Class 1 motorized, or gravity and exception taken (include leakage rating, cfm/sf); refer to HVAC System Controls for additional requirements for OSA dampers M201 Yes C403.2.4.3 Return air dampers Indicate locations of retum air dampers that are integral to economizer operation; verify dampers are motorized; indicate whether dampers are Class 1, or within packaged equipment eligible for leakage rating exception (include leakage rating, cfm/sf) M201 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 - Page 2 of 7 Mechanical Permit Plans Checklist MECH-CHK 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Project Title: Schofield Shell Date 9/26/2018 The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the Washington State Energy Code, Commercial Provisions. Applicable (yes,no,na) Code Section Code Provision Information Required - Must be in permit documents Location in Documents Building Department Notes N/A C403.2.4.3 Stairway and shaft vent dampers Indicate location of stairway and shaft vent dampers on plans; verify dampers are Class 1 motorized; refer to HVAC System Controls for additional requirements N/A C403.2.4.4 Zone isolation dampers For systems serving areas > 25,000 sf or spanning more than one floor, that include areas that are expected to be occupied non -simultaneously; identify isolation zone areas on plans and locations of associated isolation dampers in HVAC distribution system; refer to HVAC System Controls for additional requirements N/A C403.2.3.4 Humidification For cooling systems with humidification equipment that are also required to have air economizer, indicate humidifier is adiabatic (direct evaporative or fog atomization), or exception taken Additional Efficiency Package Option, More Efficient HVAC Equipment & Fan Performance - Must comply with all 3 provisions to be eligible N/A C406.2.1 C403.2.3 HVAC system selection To comply with additional efficiency package option, calculate the percentage of heating and cooling equipment in the project (based on output capacity) that do not have a corresponding WSEC listed efficiency; shall be less than 10% to comply N/A C406.2.2 C403.2.3 Minimum equipment efficiency To comply with additional efficiency package option, indicate that all listed heating and cooling equipment have a rated efficiency that exceeds WSEC listed efficiency by at least 15% N/A C406.2.3 C403.2.11.3 Minimum fan efficiency To comply with additional efficiency package option, indicate rated FEG of stand alone fans is z 71; indicate these fans are sized so the fan efficiency at design conditions is within 10% of the maximum total or static efficiency HVAC System Controls Yes C403.2.4.1 Thermostatic controls (thermostats and humidistats) Indicate locations of thermostatic and humidity control devices and the zones they serve on plans, including perimeter system zones Where adjacent (neighboring) zones are controlled by separate thermostats (including perimeter systems used to offset heat gain or loss), and are connected by permanent openings > 10% of either zone sf area, indicate controls configured to prevent adjacent zones from operating in conflicting modes (one in heat, other in cool); applies to adjacent perimeter zones, adjacent nonperimeter zones, and adjacent perimeter and nonperimeter zones M201 If applying Exception 2 to nonperimeter zones adjacent to perimeter zones, indicate that setpoints and deadband settings in these zones are coordinated so cooling in a nonperimeter zone does not occur until the temperature in that zone is 5°F higher than the adjacent perimeter zone temperature in heating C403.2.4.1.1 Heat pump supplementary heat Indicate staged heating operation with compression as the first stage of heating and supplemental heating controlled with outdoor lock -out temperature set to 40°F or less Yes C403.2.4.1.2 Deadband Indicate zone thermostatic controls configured with 5°F minimum deadband for systems that control both heating and cooling M001 Yes C403.2.4.1.3 Setpoint overlap restriction (thermostats) If separate heating and cooling systems with separate thermostatic control devices are used to serve a zone, indicate locations of both thermostatic control devices and the zone they serve on plans M001 Indicate a limit switch, mechanical stop or DDC control with programming to prevent simultaneous heating and cooling Yes C403.2.4.2 C403.2.4.2.1 C403.2.4.2.2 Automatic setback and shutdown Indicate zone thermostatic controls configured with required automatic setback and manual override functions, setback temperatures, and control method (automatic time clock or programmable controls); note exceptions taken M001 Yes C403.2.4.2.3 Automatic (optimum) start Indicate system controls that adjust equipment start time required to bring each area served up to design temperature just prior to scheduled occupancy M001 Yes C403.2.4.3 Outdoor supply air dampers Indicate automatic controls configured to close OSA damper during unoccupied equipment operation; not including economizer cooling, night flush or IMC required OSA / exhaust M001 N/A C403.2.4.3 Stairway and shaft vent dampers Indicate method of activation of stairway and shaft vent dampers (fire alarm or interruption of power) N/A C403.2.4.4 Zone isolation controls For systems serving areas > 25,000 sf or spanning more than one floor, that include areas that are expected to be occupied non -simultaneously; indicate controls that allow for independent space conditioning of isolation zones; or exception taken N/A C403.2.12 Heating outside a building Indicate occupancy sensing or timer switch controls configured to automatically shut off heating system when area served is unoccupied N/A C403.2.4.5 Snow melt systems Indicate automatic controls configured to shut off system when pavement temperature exceeds 50°F and no precipitation is falling, and when outdoor air temperature exceeds 40°F N/A C403.2.4.6 Freeze protection system controls Indicate automatic controls to shut off system when outdoor temperature exceeds 40°F, or conditions protect fluid from freezing N/A C403.2.4.9 Group R1 hotel /motel guest rooms For hotels and motels with over 50 guest rooms, indicate automatic controls serving guest rooms that are capable of setback (heating) and set-up (cooling) of temperature setpoint by at least 5°F; indicate control method - activated by room entry or occupancy sensor 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 - Page 3 of 7 Mechanical Permit Plans Checklist MECH-CHK 2015 Washington State Energy Code Compliance Forms for Commercial Buildings in - -- --.... Project Title: Schofield Shell Date 9/26/2018 The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the Washington State Energy Code, Commercial Provisions. Applicable (yes,no,na) Code SectionCode Provision Information Required - Must be in permit documents Location in Documents Building Department Notes N/A C403.2.4.10 0403.2.4.11 Group R2 / R3 dwelling units, Group R2 sleeping units For primary space conditioning system, indicate 5-2 programmable thermostats capable of two setback periods per day; for all thermostats indicate purpose (heating only, cooling only, or both), required temperature range and at minimum a 10°F deadband; or exception taken Indicate method of ventilation air delivery (natural or mechanical) for each zone Yes C403.2.6 C403.2.11.4 Ventilation If mechanically delivered, indicate that systems are configured to provide not more than 150% of, but at least the minimum required volume of outdoor air to each zone per IMC, ASHRAE 62.1 or other applicable code (WAC, OSHA, etc); or exception taken M001 If delivered via natural ventilation, identify required elements per IMC including minimum openable area to the outdoors or qualifying adjoining spaces N/A C403.2.6.2 Demand controlled ventilation Identify spaces > 500 sf with occupant load > 25 people/1,000 sf per IMC; for each space indicate whether it is served by an HVAC system with total design OSA > 3,000 cfm, and / or the system has airside economizer or automatic modulating OSA damper; indicate OSA controls are configured to provide demand controlled ventilation or provide supporthg documentation for applied exception N/A C403.2.6.3 Occupancy sensors For gyms, classrooms, auditoriums and conference rooms > 500 sf, indicate occupancy -based OSA control when space is unoccupied and method (closes OSA damper or shuts -off equipment); or alternate means provided to automatically reduce OSA when space is partially occupied N/A C403.2.6.4 0403.2.6.4.1 Enclosed loading dock ventilation For enclosed loading docks, indicate ventilation / exhaust system method of activation (gas detection system for CO and NO2, or occupancy sensors), and control method (staged or modulating) N/A C403.2.6.4 C403.2.6.4.2 Enclosed parking garage ventilation For enclosed parking garages, indicate ventilation / exhaust system activated by gas detection system for CO and NO2, and control method (staged or modulating); or exception taken N/A 0403.2.7.1 Kitchen exhaust hoods Provide calculations that show a balanced accounting of total kitchen exhaust (include all hoods) with % of: supply air, transfer air from adjacent spaces, and make-up air; if applicable, indicate that direct make-up air to each hood does not exceed 10% of hood exhaust For kitchens with total hood exhaust exceeding 2,000 cfm, indicate exhaust air rate Der Table C403.2.7.1 and compliance method (DCV, energy recovery, or transfer air that would otherwise be exhausted) N/A C403.2.7.2 Laboratory exhaust systems Refer to Systems Requiring Energy Recovery for requirements N/A C403.2.13 Variable flow capacity - HVAC system fans For HVAC fan motors >_ 7.5 hp, indicate method of variable flow control (VSD, or equivalent control method that reduces design air volume by 50% at 1/3 static design pressure); note exception taken N/A C403.3.1 DX air handler variable cooling control (Under Integrated For DX air handlers with economizer and cooling capacity >_ 65,000 Btu/h, indicate number of cooling stages provided and method (multiple compressors and / or variable speed compressors); indicate minimum displacement (capacity reduction) as % of full load Economizer) Indicate control method (cooling capacity controlled in response to space temperature, space temperature controlled by modulating supply airtlow, or both) For DX air handling units with cooling capacity >_ 65,000 Btu/h and evaporative and chilled water air handling units with fan >_ 0.25 hp, indicate whether system is single zone or multiple zone and related control method (cooling capacity controlled in response to space temperature, space temperature is controlled by modulating supply airflow, or both) N/A C403.2.11.5 Fan airflow control For mechanical cooling systems (includes DX and chilled water coils) that control cooling capacity in response to space temperature - Provide a minimum of two stages of fan control; indicate minimum fan speed is 5 66% of full speed drawing 5 40% of full speed fan power during periods of low cooling or ventilation only For other mechanical cooling systems (includes DX and chilled water coils) that control space temperature by modulating airflow (in lieu of, or in addition to, controlling capacity in response to space temperature) - Provide fan controls for modulating supply airflow; indicate minimum fan speed is <_ 50% of full speed drawing <_ 30% of full speed fan power during periods of low cooling or ventilation only; or exception taken N/A 0403.2.4.12 DDC system capabilities Provide central and zone level DDC controls as required based on system application, capacity or size thresholds and other qualification per Table 0403.2.4.12.1 Identify all DDC system input / output control points; indicate capability for trending and graphical display Ducting Systems 0403.2.8.1 Indicate on plans that all ductwork is constructed and sealed per IMC M001 Yes 0403.2.8.3 Duct construction For OSA ductwork, also indicate on plans that ductwork meets air leakage requirements per C402.5 and vapor retarder requirements per the IBC N/A 0403.2.8.3 Duct pressure classifications Identify location of low, medium and high pressure ductwork on plans N/A 0403.2.8.3.3 High pressure duct leakage test Indicate high pressure duct leakage testing requirements on plans; provide test results to jurisdiction when completed 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 - Page 4 of 7 Mechanical Permit Plans Checklist MECH-CHK 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised January 2017 Project Title: Schofield Shell Date 9/26/2018 The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the Washington State Energy Code, Commercial Provisions. Applicable (yes,no,na) Code Section Code Provision Information Required - Must be in permit documents Location in Documents Building Department Notes Yes C403.2.8.1 C403.2.8.2 Duct insulation For supply and retum ductwork located in unconditioned space or outdoors, indicate R -value of insulation on ductwork on plans; identify climate zone; note exceptions taken For supply ductwork located in conditioned space, identify if design supply temperature is < 55°F or> 105°F and indicate R -value of insulation on this ductwork on plans; note exception taken M001 For OSA ductwork, shafts and plenums, indicate R -value of insulation on these elements on plans per Table C402.1.3 for steel -framed walls; note exception taken Piping Systems WA C403.2.9 Piping insulation Indicate design temperature range of fluid conveyed in piping and thickness of insulation (in inches) on hydronic piping plans; or exception taken N/A C403.2.9.1 Piping insulation exposed to weather Indicate method of protection of pipe insulation from damage / degradation on hydronic piping plans Economizers NA C403.3 Air economizer required Identify in equipment schedules on plans or in MECH-EQ forms all cooling systems requiring air economizer controls Provide MECH-ECONO form indicating systems utilizing air economizer exceptions, including those with water -side economizer in lieu of air economizer; indicate on plans eligible exception(s) taken and measures to comply with exception(s) M001 NA C403.3.1 Integrated economizer operation - air and water Indicate air and water -side economizers are configured for partial cooling operation even where additional mechanical cooling is required to meet the load NA C403.3.2 Economizer heating system impact - air and water Verify control method of HVAC systems with economizers does not increase building heating energy usage during normal operation NA C403.3.3.1 Air economizer capacity Indicate modulating OSA and return air dampers are configured to provide up to 100% OSA for cooling NA C403.3.1 C403.3.3.2 Integrated air economizer Verify mechanical cooling controls are interlocked with air economizer controls so the outside air damper remains in 100% open position when mechanical cooling is also required to meet the cooling load, until the leaving air temperature is < 45°F For systems with cooling capacity >_ 65,000 Btu/h, verify that control of economizer dampers is not based only on mixed air temperature; or exception taken NA C403.3.3.3 Air economizer high limit controls Indicate high limit shut-off control method and required high limit per Table C403.3.3.3 N/A C403.3.4.1 Water economizer capacity For eligible systems where water -side economizer may be provided in lieu of air economizer, indicate system is capable of 100% design cooling capacity at 50°F db / 45°F wb OSA temperatures N/A C403.3.4.2 Water economizer maximum pressure drop Indicate pressure drop across precooling coils and heat exchangers in water economizer system do not exceed pressure drop limit N/A C403.3.1 DX air handling equipment control For DX air handlers with economizer and cooling capacity >_ 65,000 Btu/h, refer to HVAC System Controls for requirements N/A C403.2.4.7 DX equipment economizer fault detection and diagnostics For DX air handlers with economizer and cooling capacity >_ 54,000 Btu/h, provide a fault detection and diagnostics (FDD) system to monitor economizer system operation and report faults Systems Requiring Energy Recovery N/A C403.5.1 Energy recovery (ER) - ventilation /exhaust systems For systems with design OSA > 5,000 cfm, or design supply air cfm and % OSA exceeding the values in Tables C403.5.1(1) or (2), indicate exhaust air ER method; or exception taken with supporting calculations For rooms served by multiple systems with aggregate design OSA > 5,000 cfm, or aggregate design supply air cfm and % OSA exceeding the values in Tables C403.5.1(1) or (2), indicate exhaust air ER method; or exception taken with supporting calculations Indicate ER rated effectiveness that increases OSA enthalpy by >_ 50% based on delta between OSA and return air enthalpies at design conditions WA C403.2.7.2 Laboratory exhaust systems (energy recovery) For buildings with total lab exhaust > 5,000 cfm, indicate method of energy recovery used to pre -condition laboratory make-up air; ER effectiveness (min 25°F); or altemative method per exception (VAV exhaust, semi -conditioned makeup, or CERM calculation) N/A C404.10.4 (under C404.11) Pools and permanent spas exhaust systems (energy recovery) For buildings with pools or spas with water surface area > 200 sf, indicate exhaust air ER method and use of waste heat (preheat ventilation air, pool water or service hot water); or exception taken Indicate ER system has the rated effectiveness and is configured to decrease the exhaust air temperature at design conditions by >_ 36°F N/A C403.5.2 Energy recovery - steam condensate systems For buildings with on-site steam heating systems, indicate condensate water ER For buildings that use off-site generated steam where condensate is not returned to the source, indicate on-site condensate water ER 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 - Page 5 of 7 Mechanical Permit Plans Checklist MECH-CHK 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Project Title: Schofield Shell Date 9/26/2018 The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the Washington State Energy Code, Commercial Provisions. Applicable (yes,no,na) Code Section Code Provision Information Required - Must be in permit documents Location in Documents Building Department Notes WA C403.5.3 Energy recovery - cooler / freezer condensers For buildings with food service, meat or deli departments that have >_ 500,000 Btu/h of remote refrigeration capacity for coolers / freezers, indicate condenser ER and use of captured energy (service water heating, space heating, or dehumidification reheating) For buildings with >_ 40,000 sf conditioned floor area and with >_ 1,000,000 Btu/h of remote refrigeration capacity for coolers / freezers, indicate condenser ER and use of captured energy for service water heating and also for space heating, or dehumidification reheating WA 0403.5.4 Energy recovery - condenser systems For buildings with 24-hour operation and with > 1500,000 Btu/h of heat rejection capacity and design service hot water load > 250,000 Btu/h, indicate condenser ER to pre -heat service water; or exception taken. Provide calculations showing the amount of recovered heat that is utilized (60% of peak heat rejection load or pre -heat service water to 85°F). Hydronic System Controls N/A C403.2.13 C403.4.2.7 Variable flow control - hydronic system pumps For hydronic system pump motors >_ 7.5 hp, indicate method of variable flow control (VSD or equivalent method that requires >_30% design wattage at 50% design fluid flow); note exception taken Identify whether hydronic coils have DDC controls and associated manner of pump speed control (differential pressure, zone hydronic demand, etc) N/A C403.2.5 C403.4.2.4 Hydronic system setback and part load controls For boilers that provide building heating, indicate controls that provide heating water temperature setback based on outdoor temperature For heating and chilled water systems >_ 300,000 Btu/h, indicate systems are configured to automatically reset supply water temperature based upon demand; or exception taken. If system pump motor hp >_ 3 hp, also indicate controls automatically reduce flow by >_50%. For chilled water systems (>_ 300,000 Btu/h, pump motor hp >_ 3 hp) that serve water-cooled unitary air conditioners, indicate VSD or staged pumps in chilled water system and heat rejection loop that reduce pump flow so that one control valve is nearly wide open, or to maintain a minimum differential pressure; or exception taken N/A C403.4.2 Boiler sequencing Indicate automatic controls that sequence operation of multiple boilers N/A 0403.4.6 Hot gas bypass limitation For cooling equipment with hot gas bypass, provide either multiple step unloading or continuous capacity modulation; indicate bypass capacity per Table C403.4.6 N/A C403.4.2.2 Two -pipe changeover systems Indicate changeover deadband (min 15°F), heating / cooling mode scheduling and changeover temperature range (limit 30°F) N/A 0403.4.2.6 Chiller / boiler plant pump isolation Indicate controls are configured to automatically reduce overall plant flow and shut-off flow through individual chillers and boilers when not in use N/A C403.2.13.1.1 C403.4.3.1.1 C403.4.3.1.2 Heat rejection equipment - variable flow control For cooling towers with fan motors z 7.5 hp, indicate VSD and method to adjust fan speed (adjusted based on leaving fluid temperature or condenser temperature / pressure of heat rejection device) For multiple -cell heat rejection equipment with VSD, indicate controls that ramp all fans in unison N/A C403.4.3.3 Heat rejection equipment - cooling tower flow turndown Indicate open -circuit cooling towers with multiple pumps or VSD control are designed so all cells can be run in parallel N/A C403.4.2.3.1 Water loop heat pump - deadband Indicate capability of central equipment to provide minimum 20°F water supply temperature deadband between heat rejection and heat addition modes; or exception taken N/A C403.4.2.3.2.1 Water loop heat pump heat rejection equipment, Zone 4 Indicate type of cooling tower (open- or closed-circuit) in equipment schedule; indicate method used to limit system heat loss when heat rejection is not needed N/A C403.4.2.3.2.2 Water loop heat pump heat rejection equipment, Zone 5 For open- or closed-circuit cooling towers, provide a heat exchanger that separates the cooling tower and heat pump loop N/A C403.4.2.3.3 Water loop heat pump - isolation valves For hydronic heat pump systems with total system power> 10 hp, indicate 2 -way isolation valves on each heat pump and variable flow system control Dedicated Outdoor Air Systems (DOAS) - Optional through 6/30/16, Prescriptive 7/1/2016 N/A C403.6 C403.6.3 Dedicated outdoor air systems For buildings with office, retail, education, library and fire station spaces, identify these spaces on plans; indicate that ventilation air in each occupied space is provided via a DOAS system; or document compliance with C403.6.3 Impracticality; or exception taken (buildings complying with C402.4.1.4 or C406.6 may not utilize exceptions) N/A C403.6.1 Energy recovery ventilation with DOAS For all DOAS systems, indicate exhaust air ER method; or exception taken with supporting calculations. Indicate ER rated effectiveness that increases OSA enthalpy by z 50% based on delta between OSA and return air enthalpies at design conditions. N/A C403.6.2 Heating / cooling system controls with DOAS Indicate equipment associated with the delivery of zone level heating and cooling (farts, hydronic pumps, primary air dampers, etc) are configured to shut off, and central equipment is configured to tum down, when there is no call for heating or cooling in the zone they serve If applying Exception to heating / cooling fans used for air mixing in the space during deadband periods, include fan watts per cfm in equipment schedule 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 - Page 6 of 7 Mechanical Permit Plans Checklist MECH-CHK 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised January 2017 Project Title: Schofield Shell Date 9/26/2018 The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the Washington State Energy Code, Commercial Provisions. Applicable (yes,no,na) Code Section Code Provision Information Required - Must be in permit documents Location in Documents Building Department Notes N/A C402.4.1.4 C403.6 Increased prescriptive maximum vertical fenestration area with DOAS Indicate that all occupied, conditioned spaces are served by a DOAS per C403.6 Additional Efficiency Package Option, Dedicated Outside Air Systems (DOAS) WA C406.6 Building provided with DOAS To comply with additional efficiency package option, indicate that 90% or more of all occupied, conditioned spaces are served by a DOAS per C403.6 Multiple Zone Air Systems N/A C403.4.4 Air systems serving multiple zones Identify supply air systems serving multiple zones and the zones they serve on plans; indicate whether system is VAV and method of primary air control; or provide supporting documentation for applied exception to VAV N/A C403.4.4 VAV systems serving multiple zones Provide equipment schedules on plans or MECH-EQ form that list at VAV air terminals and types For each air terminal include: maximum airflow rates for primary supply air during zone peak heating and zone peak cooling; maximum airflow during reheating, recooling or mixing; minimum airflow rate to maintain required ventilation, and the basis for these values; if IMC or ASHRAE 62.1 multiple zone equation is basis for minimum flow rates, provide calculation on plans N/A C403.4.4.1 Single duct VAV terminal units Indicate single duct terminal units are configured to reduce primary supply air before reheating or recooling WA C403.4.4.2 Dual duct systems - terminal units For systems with separate warm air and cool air ducts, indicate terminal units are configured to reduce the flow from one duct to minimum before mixing with air from the other duct N/A 0403.4.1.1 C403.4.1.2 VAV system static pressure sensors - sensors and DDC set points Indicate locations of duct static pressure sensors on plans; include at least one sensor per major duct branch; verify controller setpoint pressure at each sensor is <_ 1.2 inch w g. For systems with zone level DDC, indicate controls are configured to monitor zone damper positions and reset static pressure setpoint based on the zone requiring most pressure; include control logic that automatically detects and generates an alarm if any zone excessively drives reset logic, and allows building operators to exclude zones from reset logic N/A 0403.4.4.3 Multiple -zone VAV system ventilation optimization controls For systems with zone level DDC controls, indicate controls are configured to automatically reduce outdoor airflow in response to changes in system ventilation efficiency; or exception taken N/A Multiple Zone C403.4.4.4 VAV system supply air reset Indicate controls automatically reset supply air temperature in response to building loads or outdoor air temperature; or exception taken HVAC Systems, High Efficiency VAV - Required for systems utilizing C403.6 DOAS Exception 2, must comply with all 16 provisions N/A C403.7, Item 1 Air economizer Indicate system is configured for 100% air economizer operation and complies with all related economizer requirements per C403.3 (without economizer exceptions) N/A C403.7, Item 2 Direct digital controls (DDC) Provide DDC controls for all components of system; identify all DDC system input / output control points; indicate capability for trending and graphical display N/A C403.7, Item 3 Outdoor airflow measurement and reduction For systems with minimum OSA > 2,500 cfm, indicate outdoor airflow monitoring station that measures OSA intake under all load conditions; indicate control sequence that increases or reduces system OSA cfm based on VAV terminal feedback of ventilation efficiency (per C403.4.4.3 without exceptions) or DCV (per C403.2.6.2) N/A C403.7, Item 4 Supply airflow measurement For systems with minimum OSA > 2,500 cfm, indicate supply airflow monitoring station capable of measuring supply air delivered to VAV terminals under all load conditions N/A C403.7, Item 5 Zone isolation and maximum area served Verify maximum area served by a single HEVAV system is 5 50,000 sf, or one entire floor, whichever is greater; in addition if a system serves > 25,000 sf, that includes areas that are expected to be occupied non -simultaneously, indicate zone isolation controls per 0403.2.4.4 N/A C403.7, Item 6 Interior / exterior zone design supply air temperature Verify that VAV terminals serving interior cooling driven loads are sized per design supply air temperature that is 5°F higher than VAV terminals serving exterior zones N/A C403.7, Item 7 Maximum air terminal inlet velocity Identify air terminals with minimum primary airflow setpoints > 50% of maximum setpoint in equipment schedule or MECH-EQ form; indicate air terminal inlet velocity does not exceed 900 fpm N/A C403.7, Item 8 Sequence of operation Indicate DDC system sequences of operation are designed and configured per ASHRAE GPC 36 N/A C403.7, Item 9 Maximum allowable system brake horsepower Verify fan system bhp is <_ 90% of the bhp limit per Option 2 equation in Table C403.2.11.1(1), provide MECH-FANSYS form for each system N/A C403.7, Item 10 Fan -powered terminal unit motor and control Indicate all series and parallel terminal fans have electronically commutated motors; indicate DDC control system is configured to vary air terminal fan speed as a function of the bad; indicate fan speed during periods of low heating, low cooling, or ventilation only is <_ 66% of peak design air flow or provide supporting documentation for applied exception • 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 - Page 7 of 7 Mechanical Permit Plans Checklist MECH-CHK 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Project Title: Schofield Shell Date 9/26/2018 The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the Washington State Energy Code, Commercial Provisions. Applicable (yes,no,na) Code Section Code Provision Information Required - Must be in permit documents Location in Documents Building Department Notes N/A C403.7, Item 11 Application of single duct and fan -powered terminal units Indicate VAV terminal types on plans; verify fan -powered terminal units only serve perimeter zones with envelope loads; verify all other zones are served by single duct terminal units N/A C403.7, Item 12 Fan -powered terminal unit primary air reset Indicate DDC controls are configured to automatically reset the primary supply air cfm setpoint of all fan -powered terminal units to the minimum required to maintain ventilation during occupied heating or deadband, based upon the VAV air handling unit OSA ventilation fraction N/A C403.7, Item 13 High occupancy space controls For spaces > 150 sf with occupant density >_ 25 people / 1000 sf, indicate space is served by a dedicated terminal unit with DCV control that resets terminal unit ventilation setpoint; also indicate occupancy sensor control that automatically reduces minimum ventilation to zero and sets back room heating and cooling setpoints by >_ 5°F N/A C403.7, Item 14 Dedicated HVAC systems For server, electronic equipment, telecom or similar spaces with cooling loads > 5 W/sf, indicate spaces are served by independent HVAC systems that are separate from HPVAV systems serving rest of building; indicate dedicated HVAC systems have air economizer controls or energy recovery per C403.3 Exception 9 N/A C403.7, Item 15 Central plant efficiency Indicate whether systems are served by a high efficiency heating water plant, or a high efficiency chilled water plant If complying via high efficiency heating water plant: Indicate all VAV terminals have hydronic heating coils served by heating water system with either gas-fired boiler(s) with thermal efficiency t 90%, air -to -water heat pumps, or heat recovery chillers If complying via high efficiency chilled water plant: Indicate all VAV air handlers have cooling coils served by chillers with rated IPLV efficiency that exceeds WSEC listed IPLV by at least 25% per Table C403.2.3(7) (note water-cooled IPLV is max, all others are min); indicate smallest chiller or compressor in plant is <_ 20% of total plant capacity, or provide thermal storage sized for 5 20% of total plant capacity N/A C403.7, Item 16 Fault detection and diagnostics Indicate DDC system includes a fault detection and diagnostics (FDD) system configured to monitor operation and provide fault reporting of required parameters for all VAV air handlers and VAV air terminal units in the HPVAV system HVAC Equipment Energy Use Metering N/A Documentation C409.3.1 HVAC equipment energy use metering For new buildings > 50,000 sf and building additions > 25,000 sf, verify energy use metering of all equipment used to provide space heating and cooling, dehumidification and ventilation will be provided per C409; indicate equipment eligible for exception and System Specific Requirement To Support Commissioning Yes C408.2 Scope of mechanical systems commissioning Indicate that all mechanical systems, equipment, and controls for which the WSEC requires control functions and / or configuration to perform specific functions are required to be commissioned; M001 For buildings with >_ 240,000 Btu/h total output cooling capacity or >_ 300,000 Btu/h total output heating capacity, indicate that all mechanical systems regardless of individual capacity are required to be commissioned; or provide building heating / cooling capacity calculation demonstrating eligibility for exception C403.2.10 C408.1.1 C408.1.2 C408.1.4.2 C103.6 Commissioning requirements in construction documents Indicate in plans and specifications that Cx per C408 is required for all applicable mechanical systems; Yes Include general summary with at a minimum of Items 1 thru 4 of the Cx plan per C408.1.2 including: narrative description of activities, responsibilities of the Cx team, schedule of activities including verification of project close out documentation per C103.6, and conflict of interest plan (if required); M001 Include in general summary that a Cx project report or Compliance Checklist (Figure C408.1.4.2) shall be completed by the Certified Cx Professional and provided to the owner prior to the final mechanical inspection. Yes C408.2.2 Air system and hydronic system balancing Indicate in plans that air and fluid flow rates shall be tested and balanced within the tolerances defined in the specifications; indicate systems shall be balanced in a manner to first minimize throttling losses, then adjusted to meet design flow conditions M001 Yes C408.2.2.1 Air system balancing devices Indicate devices that provide the capability to balance all supply air outlets, zone terminals and air handling equipment requiring system balancing M001 WA C408.2.2.2 Hydronic system balancing devices Indicate devices that provide the capability to isolate, balance and measure flow across all hydronic equipment requiring system balancing including heating and cooling coils and pumps Yes C408.2.3 Functional performance testing criteria Identify in plans and specifications the intended operation of all equipment and controls during all modes of operation, including interfacing between new and existing -to -remain systems M001 Project Close Out Documentation Yes C103.6 Documentation and project close out submittal requirements Indicate in plans that project close out documentation and training of building operations personnel is required for all mechanical components, equipment and systems govemed by this code; indicate close out documentation shall include: record documents, O&M manuals, applicable WSEC compliance forms and calculations M001 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 Mechanical Fan System Power Allowance MECH-FANSYS-SUM 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised January 2017 Project Title: Schofield Shell Date 9/26/2018 For Building Dept. Use HVAC Air Distribution System Schedule List all HVAC systems that have the capability to provide heating and/or cooling to the spaces they serve. System or Primary Supply Fan ID Speed Control (Note 1) Description (Note 2) System Total Nameplate HP (Note 3) Fan Power Calculation Required (Note 4) RTU -1 CV Rooftop packaged heating/cooling unit 1 No Note 1 - Constant Volume (CV), Variable Air Volume (VAV), or Hospital/Lab CV system that qualifies for VAV budget per C403.2.11.1 Exception 1. Single zone VAV systems shall comply as CV. Note 2 - Describe system type and list all fans (or groups of fans) associated with the delivery and removal of conditioned air by the system. Include all supply, return/relief, exhaust and exhaust hoods (>1 hp), make-up air, dedicated outside air (DOAS), booster fans, and series fan -powered terminals. VAV parallel fan -powered terminals and economizer relief fans do not need to be included if the fans do not operate at peak conditions. Note 3 - Enter the total nameplate hp of all fans associated with the delivery and removal of conditioned air by the system. Note 4 - This form automatically identifies whether a MECH-FANSYS form is required to demonstrate compliance with the fan power allowance (Yes), or this information is not required because the system has a combined total nameplate motor hp that is 5 hp or less (No) MECH-FANSYS Forms A MECH-FANSYS form shall be provided for each system with total nameplate hp greater than 5 hp. Select (Add Fan System Form) to generate an additional form. Added forms can be deleted with button in cell E32 of the added form. CT ENGINEERING Client: Design Criteria: INC #18174 Construction Documents For: SCHOFIELD TI RTU SUPPORT AT 16915 Southcenter Pkwy Tukwila, WA 98188 09/24/2018 Evergreen Refrigeration & HVAC 727 S. Kenyon St. Seattle, WA 98108 IBC 2015 Wind: Wind Speed = 85 mph, Kzt = 1.00 Seismic: Sds = .9 Roof Snow Load = 25 psf 180 Nickerson St. Suite 302 Seattle, WA 98109 (206) 285-4512(V) (206) 285-0618(F) bmccann@ctengineering.com REVIEWED FOR CODE COMPLIANCE APPROVED OCT 10 2018 • City of Tukwila BUILDING DIVISION RECEIVED CITU OF TUKW LA SEP 2 6 2018 P,LiE aT CENTER MIS- 01214 Sc hofi,eld Tl RTU 16915 Southcenter TI Tukwila, WA 98188 egend t• (N) ! TU .. ;° ib max (N) C ur _ ib max REFER " C) A. E. C AND D FOR ANCHORAGE DIRECTION OF RTU, E0 NEW CURE AND CURB ..[O EXISTING ROOF STRUCTURE CT ENGINEERING SEISMIC CLIPS, RE: PLACEMENT PLAN AND PROFILE FLAT 2x6 TO LEVEL 2x6 BLOCKING 0 UNIT 3/4" T&G PLYWOOD (E) GLB I N C. RTU - 750 LB MAX CURB - 150 LB MAX 2x4 LOAD TRANSFER BLOCK AT TWO BOTTOM CHORD PINS SCALE: 3/8" =1'-0" A 180 Nickerson St. Suite 302 Seattle, WA 98109 (206) 285-4512 FAX: (206) 285-0618 SDS25300SS ® 24" 0.C. 2x6 RIPPED TO LEVEL UNIT W/ SDS25600 0 24" O.C. 4x6 BLOCKING W/U46 HANGER PROVIDE RETURNING 4X6 FROM BLOCKING TO BEAM W/ SIM. HANGER (E) TRUSS 2x6 EACH SIDE OF TOP CHORD. W/16d ® 6"O.C. & 2-16d TO EACH LOAD TRANSFER BLOCK. 6" MIN. DISTANCE TO TOP CHORD PINS TYP. TYPICAL RTU AT BEAM / JOIST C� T ENGINEERING INC. R.T.U. 14GA. Z CUP RE: D FOR PROFILE RE: C FOR PLACEMENT DIAGRAM. RE: A SCALE: 1 1/2" = 1'-0" B (N) CURB NEW R.T.U. AT (N) CURB 180 Nickerson St. Suite 302 Seattle, WA 98109 (206) 285-4512 FAX: (206) 285-0618 C T ENGINEERING SCALE: NONE C 1 N C. LENGTH L/4 L/4 NOTE: RE: D FOR SEISMIC CLIP PROFILE. 180 Nickerson St. Suite 302 Seattle, WA 98109 (206) 285-4512 FAX: (206) 285-0618 TYPICAL CLIP PLACENENT DIAPHRAG V C T ENGINEERING (4) #10 TEK SCREWS I N C. 1 1/4. • 4 3/4" X11/4♦ SCALE: 1 1/2" = 1'-0" D 2" 2 5/8" TYPICAL SEISMIC CLIP 14 GAUGE GALVANIZED (4) #10 TEK SCREWS TYPICAL SEISMIC CLIPS 180 Nickerson St. Suite 302 Seattle, WA 98109 (206) 285-4512 FAX: (206) 285-0618 s C T ENGINEERING Client: Design Criteria: INC #18174 Structural Calculations For: SCHOFIELD TI RTU SUPPORT AT 16915 Southcenter Pkwy Tukwila, WA 98188 09/24/2018 Evergreen Refrigeration & HVAC 727 S. Kenyon St. Seattle, WA 98108 IBC 2015 Wind: Wind Speed = 85 mph, Kzt = 1.00 Seismic: Sds = .9 Roof Snow Load = 25 psf 180 Nickerson St. Suite 302 Seattle, WA 98109 (206) 285-4512(V) (206) 285-0618(F) bmccann@ctengineering.com REVIEWED FOR CODE COMPLIANCE APPROVED OCT 10 2018 City of Tukwila BUILDING DIVISION RIECEINED COTY O I'CJCI CLQ SFP262018 ER T CENTER (9.0119 Schofield TI RTU 16915 Southcenter TI Tukwila, WA 98188 RTU - 750 I Curb - 150 lb max C T ENGINEERING Project: Client: Page Number: 180 Nickerson St. Suite 302 Seattle, WA 98109 (206) 285-4512 FAX: (206) 285-0618 ‘�,q,,G/?77 Ca.12i oe&- Ar1,O /414 2121 892+ 84)5 = q‘f 14440 112, 4- Edie-bLptsin 45u -sr f 1-> l v T•j 44,041- mgr- w�. av- 24 i 980 �- 6rlt ? 44261 tre Z4400 4-4 2 -?,,q94) Ir CT ENGINEERING 1 N C. WIND LOADS - EQUIPMENT (BLDG H < 60') ASCE 7-10 29.5-1 V 110.0 mph Kd 0.85 - Table 26.6-1 Kzt 1.0 - Kz qh GCrh GCry 0.62 - Table 29.3-1- Exp B 16.3 Ib/ft^2 1.9 - 1.5 - 180 Nickerson St. Suite 302 Seattle, WA 98109 (206) 285-4512 FAX: (206) 285-0618 Unit dimensions - weight - horizontal and vertical projected areas (inches; pounds; inches^2) RTU L B he H W -unit W -curb Afl Af2 Af3 Af4 Ar RTU -1 83 2/7 47 43.4 14 742 150 1166 658 3615 2040 3915 RTU -2 RTU -3 RTU -4 C T ENGINEERING 1 N C. WIND LOADS - EQUIPMENT (BLDG H < 60') 180 Nickerson St. Suite 302 Seattle, WA 98109 (206) 285-4512 FAX: (206) 285-0618 Moments about x -x Axsis ( El: Wind forces - Overturning moment (Ib -in) - Resisting Moment (Ib -in) ASCE 10 2.4.1 #7 .6D+.6W - Uplift force (Ib) RTU Fhl*(0.6) Fv*(0.6) OM RM Uplift - ASD RTU -1 151 399 10442 10462 0 RTU -2 RTU -3 RTU -4 Moments about y -y Axsis El: Wind forces - Overturning moment (Ib -in) - Resisting Moment (Ib -in) ASCE 10 2.4.1 #7 .6D+.6W - Uplift force (Ib) RTU Fh2*(0.6) Fv*(0.6) OM RM Uplift - ASD RTU -1 85 399 17232 18543 -16 RTU -2 RTU -3 RTU -4 Moments about x -x Axsis (l E2: Wind forces - Overturning moment (Ib -in) - Resisting Moment (Ib -in) ASCE 10 2.4.1 #7 .6D+.6W - Uplift force (Ib) RTU RTU -1 467 399 27121 12577 RTU -2 RTU -3 RTU -4 Moments about y -y Axsis E2: Fh3*(0.6) Fv*(0.6) OM RM Uplift - ASD WORST CASE UPLIFT FORCE - STANDARD SEISMIC CLIPS BETWEEN RTU AND CURB AND SCREWS BETWEEN CURB AND ROOF 4)( ACCEPTABLE TO ANCHOR PER CONSTRUCTION DOCUMENT DETAIL. Wind forces - Overturning moment (Ib -in) - Resisting Moment (Ib -in) ASCE 10 2.4.1 #7 .6D+.6W - Uplift force (Ib) RTU Fh4*(0.6) Fv*(0.6) OM RM Uplift - ASD RTU -1 264 399 26643 22291 52 RTU -2 RTU -3 RTU -4 SUBMITTED TO CT LENNO0 ENGINEERING INC. Product Submittal Project Information Project Name: Schofield Shell TI Project Number: 3000816156 Project Location: SEATTLE, WA 98108, US Project Altitude: 500 Customer Information Company Name: Evergreen Refrig LLC Company Address: 727 S Kenyon St Company Location: Seattle, WA 98108-4327 Contact: Phone: 206-763-1744 Engineering Information Company Name: Company Address: Company Location: Contact: Phone: We are pleased to provide the attached project submittal. If you have any questions or need additional information, please feel free to call our office. Project: 3000816156 Schofield Shell TI Quote: 4000959979 Schofield Shell TI Page 1 of 7 Last Changed: DYE, KATELYN Prepared On: 2018-09-04 Phone: 602-281-7186 Lennox Industries Inc. - Product Submittal Table of Contents System ID Qty Model Description 4T HP 1 KHB048S4B PKGHP/4 TON/460-3 Project: 3000816156 Schofield Shell TI Quote: 4000959979 Schofield Shell TI Page 2 of 7 Last Changed: DYE, KATELYN Prepared On: 2018-09-04 Phone: 602-281-7186 Lennox Industries Inc. - Product Submittal System ID: 4T HP Package Model: KHB048S4B Description: PKGHP/4 TON/460-3 HEATING PERFORMANCE Unit Type HP Output@Design H/E HighOutput System HeatOutput Packaged Heat Pump 19950 (Btuh) 23519 (Btuh) 43469 (Btuh) HP DesignTemp Electric Heater H/E Heat Rise HP COP@17° HP COP@47° 0.0 (°F) 7.5 (kW) 13.6 (°F) 2.40 3.70 COOLING PERFORMANCE Refrigerant ARI EER ARI SEER ARI Total Power ARI GrossTotalCool ARI NetTotalCool Coil GrossTotalCool Unit NetTotalCool Coil GrossSensCool Unit NetSensCool HSPF R -410A 11.4 14.0 4200 (W) 48700 (Btuh) 46500 (Btuh) 50350 (Btuh) 48530 (Btuh) 38266 (Btuh) 36446 (Btuh) 8.0 Number Compressors Number of Cooling Stages Condensate Drain Size Cooling OutdoorDB Cooling OutdoorWB Cooling CondenserDB Cooling MixedDB Cooling MixedWB Coil DischargeDB Coil DischargeWB Unit DischargeDB Unit DischargeWB Coil MoistureRemoval System MoistRemoval 1 1 1.00 (in.) 95.0 (°F) 90.0 (°F) 90.0 (°F) 80.0 (°F) 67.0 (°F) 56.9 (°F) 56.5 (°F) 57.9 (°F) 56.9 (°F) 11.4 (lb/hr) 11.4 (lb/hr) SUPPLY FAN PERFORMANCE Supply AirFlow ExtStaticPress Supply SupplyFan Req'dPower SupplyFan NomPower Supply Fan Type SupplyDriveReq'd RPM SupplyDrive Min RPM SupplyDrive Max RPM 1600 (cfm) 0.80 (in.WC) 0.58 (hp) 1.00 (hp) CAV Belt Drive 1073 (rpm) 745 (rpm) 1117 (rpm) TotalStaticPress Wet Coil Static Press Electric H/E Static Press Air Filter Qty Air Filter Length Air Filter Width Air Filter Thickness 0.96 (in.WC) 0.04 (in.WC) 0.12 (in.WC) 4 20.0 (in.) 20.0 (in.) 2.0 (in.) ELECTRICAL Voltage Frequency System MCA System MOCP Compressors RLA Cooling FLA Total Unit Oper Range -Nom Voltage 460V 3Ph 60 (Hz) 22.0 (amp) 25 (amp) 5.5 (amp) 8.7 (amp) +/- 10% SupplyFan FLA CondensingUnit FLA CondenserFan Power 2.1 (amp) 1.1 (amp) 290 (W) DIMENSIONS Cabinet Width Cabinet Length Cabinet Height Total Weight 47.0 (in.) 83.3 (in.) 43.4 (in.) 742 (Ib) Downflow Supply Length Downflow Supply Width Downflow Return Length Downflow Return Width 18.0 (in.) 20.0 (in.) 11.0 (in.) 29.0 (in.) SOUND Outdoor Sound Rating 76 (db) Project: 3000816156 Schofield Shell TI Quote: 4000959979 Schofield Shell TI Page 3 of 7 Last Changed: DYE, KATELYN Prepared On: 2018-09-04 Phone: 602-281-7186 Lennox Industries Inc. - Product Submittal System ID: 4T HP Package Model: KHB048S4B Description: PKGHP/4 TON/460-3 SYSTEM FEATURES Durable Outdoor Enamel Paint Finish Scroll Compressor High Capacity Driers Separate Compressor and Controls Compartment High Pressure Switch (Manual Reset) Crankcase Heater Test Limited compressor warranty of 5 years Limited warranty on all other components of 1 year See Limited Warranty Certificate included with unit for details INCLUDED SYSTEM OPTIONS - FACTORY INSTALLED 2 IN MERV4 FILTER CONSTANT AIR VOLUME BELT DRIVE INCLUDED SYSTEM OPTIONS - FIELD INSTALLED 11F51 14W39 1 1 CICURB71A-1 DNFLOW HYBRID CURB 14" T1EH0075AN1G 7.5KW 460-3 Project: 3000816156 Schofield Shell TI Quote: 4000959979 Schofield Shell TI Page 4 of 7 Last Changed: DYE, KATELYN Prepared On: 2018-09-04 Phone: 602-281-7186 Lennox Industries Inc. - Product Submittal System ID: 4T HP Package Model: KHB048S4B Description: PKGHP/4 TON/460-3 DIMENSIONS UNIT - INCHES (MM) Model No. AA Base lbs. kg Max. lbs. kg BB Base lbs. kg CORNER Max. lbs. kg WEIGHTS CC Base lbs. kg Max. lbs. kg Base lbs. kg 00 Max. lbs, kg CENTER EE Base in. mm OF Max. in. mm GRAVITY FF Base in. mm Max. in. mm 024 119 54 140 64 149 67 153 69 165 75 170 77 133 60 201 91 38 965 43-3/4 1111 22-1/456522-1/4 565 030 119 54 140 64 149 67 153 69 165 75 170 77 133 60 201 91 38 965 43-314 1111 22-11456522-1/4 565 036 119 54 140 64 149 67 153 70 165 75 170 77 133 60 201 91 38 965 43-3/4 1111 22-11456522-114 565 048 128 58 153 69 159 72 177 80 197 89 239 109 158 72 198 90 3.8 965 39 991 21 533 20 508 060 137 62 158 72 170 77 175 79 210 95 236 107 169 77 223 101 38 965 41 1041 21 533 20 508 074 160 73 185 84 180 82 208 94 233 106 269 122 207 94 239 108 46-1/4 1174 46-1/4 1174 20-1/2521 20-1/2 521 Base Un1: - The ung with 5'.andar'd heat exsstanger NO OPTIONS. Wu. Un8 - The un': with ALL OPTIONS Installed (Econorhtzer, etc.). 45 41143)—� foo 47(1194) BASE _I END VIEW Project: 3000816156 Schofield Shell TI Quote: 4000959979 Schofield Shell TI Page 5 of 7 55,e Jul 1 7 4178} 21 47 ( 194) BASE 17) 41--i„4- 16- 114 18 it (413) 4457) 42791 DO BOTTOM 1 5 4127) RETu4LN f AR OPENING 20 BOTTOV (505) SUPP..Y J AIR OPEMNG 6-5,84 (tea) \ CENTER OF GRAVITY FF 26-112 Borrow 4673) OOM,10E2SATE OUT`_Er 25.34 (654} — 9-1/2 (241) 80TTO1f POWER ENTRY 3X8(76X203) TOP VIEW (Base) 83.114 (21 15) +063024 thru 048 and 0605 95.-114 (2445) KHB06014 thra 674 6, � 1X Rm ff n„ 7t 3-112 894 THgj.t-112 LWFTNGHOiES H26-11 16larh99n9) 851M 63 (2165) $0024 twu 048 and 050S BASE r 951 M 42496) hO460e01H Mu 674 BASE SIDE VIEW COI;d?ErsAT£ OUTLET (EITHER 5)06) (\ � }5-1n 4440) ELECTRICAL 61..." 7 ET 111 III I I I I1 II h 1 II 89 CC it 1 (25) 19-112 183.9 4279) (495) (467) I2451 1 II II lii,IllSI 11: I I l Iii 11111 I IIII I 4) -/ 0 4 29 1.737) FORK_ FTSLOTS 55(j2 HORIZONTAL HORIZONTAL 51n (Frost, Back and 4)40) SUPPLY AR RETURN AR 4140) Bowe End) OPENING OFENNNG BACK VIEW (Wt3 o.. [cementer} Last Changed: DYE, KATELYN Prepared On: 2018-09-04 Phone: 602-281-7186 Lennox Industries Inc. - Product Submittal System ID: 4T HP Package Model: KHB048S4B Description: PKGHP/4 TON/460-3 DIMENSIONS -ACCESSORIES - INCHES (MM) HYBRID ROOF CURBS • DOUBLE DUCT OPENING -STANDARD AND FULL PERIMETER 41-1/2 M5/ (1054) 14 (356) 18 (457) 24 (810) 1-3/4 (44) — •RETURN OPENING—.. • TYPICAL FLASHING DETAIL FOR ROOF CURB 13A5E BOTTOM FIBERGLASS INSULATION {Furnished) NAILER STRIP {Furnished] ROO F C URB {Exlerds ami.wel entre perimeter at witty RIGID INSULATION {Feld Supplied) PACKAGED UNIT COUNTER FLASHING / (Feld Supplied) CANT 57 RIP {Feld Suppled) ", ROOFING .001`/MAT ER WL Ar NOT E - Rootdedti may be o(retied vilhin derides of curb DETAIL ROOF CURB 203) 14 '356) 12 (457) 24 (610 } 1314 (44) IL 1/2 (13) FACTO RYINSTALLED PERIMETER WOOD NAILER STRIP 1-314 (44) Model No. A in. mm B in. mm Standard - 024, 030, 036, 048, 0605, ' 060H, ' 074 79-3/4 2026 76-1/4 1937 Full Perimeter - 060H, 074 92-3/4 2356 89-1/4 2267 ' 0130H and 074 models can be used on smaller 79.14 in. (2026 rrm) roof curbs (nd fill perimeter) with 15-3fi1 in.(400 mm)oroerhang at candenserend ofunit. See dmension drawing on page 0. Project: 3000816156 Schofield Shell TI Quote: 4000959979 Schofield Shell TI Page 6 of 7 Last Changed: DYE, KATELYN Prepared On: 2018-09-04 Phone: 602-281-7186 Lennox Industries Inc. - Product Submittal System ID: 4T HP Package Model: KHB048S4B Description: PKGHP/4 TON/460-3 UNIT CLEARANCES - INCHES (MM) C OUTDOOR NR H000 D —tY •f— B —� A 1 Unit Clearance in. A mm in. B mm in. C mm in. D mm Top Clearance Service Clearance 36 914 36 914 36 934 36 914 Unobstructed Minimum Operation Clearance 36 914 36 914 36 914 36 914 NOTE - Entire perimeter of unit base requires support when elevated above the mounting surface. 1 Service Clearance - Required for removal of serviceable parts. Minimum Operation Clearance - Required clearance for proper unit operation. Project: 3000816156 Schofield Shell TI Quote: 4000959979 Schofield Shell TI Page 7 of 7 Last Changed: DYE, KATELYN Prepared On: 2018-09-04 Phone: 602-281-7186 11/1/2019 City of Tukwila Department of Community Development ALEX BURKHART 727 S KENYON ST SEATTLE, WA 98108 RE: Permit No. M18-0124 SCHOFIELD SHELL TI 16915 SOUTHCENTER PKWY Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 12/4/2019. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 12/4/2019, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: M18-0124 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 5/31/2019 1 City of Tukwila Department of Community Development ALEX BURKHART 727 S KENYON ST SEATTLE, WA 98108 RE: Permit No. M18-0124 SCHOFIELD SHELL TI 16915 SOUTHCENTER PKWY Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 7/9/2019. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 7/9/2019, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, ez,(Ad,tza:k 42;7 Kandace Nichols Permit Technician File No: M18-0124 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 1 PERMIT COORD COPY" PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M18-0124 DATE: 09/26/18 PROJECT NAME: SCHOFIELD SHELL TI SITE ADDRESS: 16915 SOUTHCENTER PKWY X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: Building Division Public Works Fire Prevention Structural Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 10/02/18 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) DUE DATE: 10/30/18 Approved with Conditions Denied (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 EVERGREEN REFRIGERATION 14-c Home Espanol. Contact Safety & Health Claims & Insurance Washington State Department of JLabor & Industries Page 1 of 3 Search L&I I t 1 A -Z Index Help My L&I Workplace Rights Trades & Licensing EVERGREEN REFRIGERATION LLC Owner or tradesperson Principals PATTON, RODGER, PARTNER/MEMBER PATTON, MATTHEW, PARTNER/MEMBER Patton, Adam, PARTNER/MEMBER Patton, Douglas, PARTNER/MEMBER EVERGREEN REFRIGERATION LLC, PARTNER/MEMBER PATTON, DAVID, PARTNER/MEMBER (End: 01/21/2014) Doing business as EVERGREEN REFRIGERATION LLC WA UBI No. 602 512 953 727 S KENYON ST SEATTLE, WA 98108 206-763-1744 KING County Business type Limited Liability Company Governing persons RODGER PATTON MATTHEW ALAN PATTON; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. EVERGRL954R2 Effective — expiration 01/06/2006— 01/06/2020 Bond Merchants Bonding Co (Mutual) Bond account no. WA 15097 $12,000.00 Received by L&I Effective date 12/15/2011 01/01/2012 Expiration date Until Canceled Insurance Nationwide Mutual Ins Co $1,000,000.00 Policy no. ACP 3037246151 Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602512953&LIC=EVERGRL954R2&SAW= 10/17/2018 EVERGREEN REFRIGERATION LLC Received by L&I ` Effective date 07/24/2018 07/31/2018 Expiration date 07/31/2019 Nationwide Mutual Ins Co Policy no. ACP 3018338030 $1,000,000.00 Received by L&I Effective date 07/20/2018 07/31/2018 Expiration date 07/31/2019 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID 422,456-02 .............. Doing business as EVERGREEN REFRIGERATION LLC Estimated workers reported Quarter 2 of Year 2018 "Greater than 100 Workers" L&I account contact T4 / CASSANDRA SMITH (360)902-5632 - Email: SMCA235@Ini.wa.gov Account is current. Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes ............... .................... No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 10/24/2014 Inspection no. 317607380 Location 207 SW 156TH St Burien, WA 98166 Inspection results date 10/01/2014 Inspection no. 317583862 Location 3411 South 23rd st Tacoma, WA 98405 Violations No violations Page 2 of 3 Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602512953&LIC=EVERGRL954R2&SAW= 10/17/2018 ' i 7 .1 1 t .'nrl •'e;1Sr t•r:.Llff • :ter :pan? 9 I: -I. fr‘.1e.1 •,.: LI Brno Airy 9 A+,:,t,ah her Ritz E- z rV1UC}'s ir and Oat ;rt tiory; SOUTHCENTER Map data ©2018 Google VICINITY MAP1,0 NOT TO SCALE DAIKIN CONTROL PANEL IN UNIT CONTROL BOARD CONTROL DIAGRAM FOR INTAKE AND EXHAUST DAMPERS ROOF HOOD SCHEDULE MARK MANF. MODEL CFM HOOD SIZE RH I GREENHECK FGR-18" x 18" 1,200 28"x36" IH I GREENHECK FGI-18" X IB" 1,200 28"x36" NOTES: I. WITH MOTORIZED DAMPERS ELECTRIC DUCT HEATER SCHEDULE MARK MANF. MODEL KW VOLTAGE PHASE AMPS DH-I TUTCO ED2 8.0 208 10 38.5 NOTE: WITH 24 V THERMOSTAT WIRED BY ELECTRICIAN. ENERGY RECOVERY VENTILATOR SCHEDULE MARK MANF. MODEL CFM S.P. VOLTS PHASE >104 NOTES ERV-I DIAKIN VAMI200GVJU 1200 0.5" 208-230 10 0l I NOTES: I. WITH 2 24" X 24" FILTERS ON OSA INTAKE AND RETURN MD IN DUCTWORK OR HOOD DUCT HEATER ERV DETAIL NOT TO SCALE COMMISSIONING PLAN ALL COMMISSIONING OF HEATING. VENTILATION AND AIR CONDITIONING SYSTEMS AS REQUIRED BY SECTION C408 "SYSTEM COMMISSIONING" OF THE 2015 WASHINGTON STATE ENERGY CODE (WSEC) SHALL BE PERFORMED BY EVERGREEN REFRIGERATION. LLC. THE ACTIVITIES TO BE ACCOMPLISHED ARE PER THE SECTIONS LISTED IN THE "COMMISSIONING COMPLIANCE CHECKLIST" SHOWN BELOW. AT THE COMPLETION OF THE ACTIVITIES REQUIRED FOR COMMISSIONING AS DEFINED BY SECTION C408 OF WSEC THE "COMMISSIONING COMPLIANCE CHECKLIST" WILL BE REVIEWED WITH THE BUILDING OWNER OR THE OWNER'S REPRESENTATIVE AND THIS CERTIFICATION WILL BE SIGNED AND DATED. THIS WILL SATISFY TO THE CODE OFFICIAL THAT THE REPORT HAS BEEN ACCEPTED AS REQUIRED BY SECTION C408.1.3 OF WSEC. PRO)ECT INFORMATION COMMISSIONING MAN (SECTION C4011.1.2) SYSTEMS BALANCDIG (SECTION CAO408,2.2) NATO TONAL TESTING (SECTION C408.2.3) COMMISSIONING COMPUAMCECIEtlRLST Pitied Name: Prefect A4Me•c Commleilettleg Aewbwg: ❑ OME.YEL.lq Nee •En ad twig wNL. 4...r bdsbd Ten baker • A NLMAnIE 0f9OETM OF ACnnMS Y. TIE M UNK DIMMED M Atomism fad OF • MEAORME EMfNA Pr 9MNAN E • RETOOK To DE TWO a- S. San complotod • AM Yn N,NOc SKIMS AM PRIPCRTIONETELT IALIND R A MAYER TO MT TWEE TMOTTIMC IS • TEST PORTS YE BRBA® M EL0I KM FOR ISAI* i PRESSURE ACROSS M KW ❑ HYAC Egf}-M- RSMSMeel Tartly In Moe .alrMbN (Seance 0008,2,3,9 MIK EwNEW NM MIMEO TO SBOSTRAR IE nTMIATON 4I0 PfRMw C CaagfRM. MIDIS N. SRIEM414WO4 MTBIAONS wO4TONNES Ill ACWOANE TIN KNOW TENT MO SPECIFICATIONS ❑ HVAC Cnh.Y Rarest Tasting Ion Pea D.Isletd (Stan. C4D8,2,32) 1E/[ TMPi$ wM EMI TESTED TO ROSE TOT CONTROL PNES A¢ EMWTO, NASRO M. MATT ,TIIR.Y. MAKES E KKK TOM NAE BEEN OPTIONALLY TESTED TO BQLH HEY OPERATE W ACCORDANCE OM 1111nO PLOT YIO SIECEMATO$ ❑ lIceeetetteis R:Irus..l Testier M. bore aaeyla.A IS mow 0•06.2.3.3) TPMR:ES OPERATE IN MttQaME RIM MMY/ACIPeI'S YECNIELTIBE SUPPORTING DOCUMENTS (SECTION CI03.6) CONIUSSIONIMG REPORT (SECTION C408.1.4. I) CERTIFICATION • N Seale mend Sonata .d lowliest how bees l.swbw or me eddsrA • MIEN DO011o TAIMM NA5 KEN POKED To TIE OMER OR SCHEMED Olt • RECORD NaiOHS NIE EEE 19SIITTEO 100IEA OR 10IEM1D OAR: • IRONING NIS Ewa OMIETE a 1SENEID wR: ❑ Lemony C.aINrwleR Report s.bnM.A to Owns Nod Iodides Porn below • (EMOTES KWIC PORNO RSTIC .1IEO IV TOE SECTION MKT EKE NOT BEEN 0181cm0 AT TIE TIC P 18Pr IrtfuumN • DEFINED TESTS MOM CONK OE EMmID AT HE lit P REVOLT MEVAfh101 M TO 4NATM (RO10S. ❑ 11691(EROFT 'WO ML lealleBITS FOR COeMSw.IE 'SWE BEEN (OWIUTIO M =ROOM OM THE WtlNMTOI STAR EnMY COON ,c.i..it' aL TIE REPO ARE. tame Ora r 0N0S R EPMSBITATTE MR 1.1 SCHEMATIC SITE PLAN I TENANT LOCATION MAP 1 a' F e<:r ---- IA 2st...Ey a ..__...?Y,_ _ LS s'1.4r. ABTA • ,_„ , .t I.., n. ,'d r 1 1 !E I IP(• 1 • • .1 ...1._- ) C -1 J Mom_ i it jj I Mljilj 1 I rD... .,. inter -A SOUTHCENTER PKWY • 1A �r I I I I • „., 'WO AL .4 -,., •f i 4,__ ••<`zj'•..,-5s= ." N,i j 'S ": TAD - \, t I ...-0.,....-0.,.."-,rI•A1 •r s••'1 : PP I ; �, . f fGLH4-0..fa• . b I 1 3 1 a I e _I a_I_T 4".Me • .b ei 9. e w war :I •.IE M• .slid' •1 !•T .� i -_.• ••✓%2 .,.,L • at ea 9" • tN'• -.... �..• II .r arse•-•..-, CENTER SITE PLAN O FL"KTN DEC.Q4 ay I No Changes abet!!be made to the scow:- of work !se-17 : t prior 22provai of T':' -;'.1 C-•..12 ncg Division i:37.E._.::,-:...al JIi,yere a ncwpfan soon' and may irc.:Dde z& onal pan review few HEAT PUMP PACKAGE EQUIPMENT SCHEDULE MARK MANF. MODEL TONS. SP FAN MOTOR AIRFLOW COOLING HEATING @47° ELECTRICAL STRIP HEATER WEIGHT FILTER SIZES NOTES CFM y TOTAL SEER EER TOTAL COP HSPF VOLTS PHASE MCA POWER INPUT T HEAT CAPACITY BTUH BTUH (V) KW BTUH LBS NO. (LAUD) RTU-I LENNOX KHB048S48 4 0.8 I HP 1,600 46,500 14.0 11.4 48,770 3.7 -- 460 30 22" 7.5 23,519 742 4 (20" X 20" x 2") I NOTES: I. ECONOMIZER NOT REQUIRED PER WSEC 2015 C403.3 EXCEPTION #1 "-INCLUDES STRIP HEATER FILE COPY Permit No. VIIS- OR A( Plan revic',i EI= :C :1 :u subject to c :C:G ApprovcJ of c s tho violation c;f er,/ a, opt:J co;:a erordi of approval Fidd Copy end condwons is Ey: Date: City of Tukwila BUILDING DIVISION A. GENERAL NOTES DUCTWORK 1.1 ALL DUCT DIMENSIONS ON PLAN ARE CLEAR INSIDE DIMENSIONS, ADD 2" TO EACH DIMENSION TO OBTAIN OUTSIDE DIMENSION. ADD 4" TO EACH DIMENSION IF THE DUCTWORK IS ON THE INTERIOR OF THE BUILDING. 1.2 THE FIRST NUMBER ON ALL DUCT DIMENSIONS IS THE WIDTH AND THE SECOND IS THE HEIGHT. 1.3 MATERIALS WITHIN DUCTS OR PLENUMS SHALL HAVE A FLAME SPREAD RATING LESS THAN 25 AND A FLAME SMOKE DEVELOPMENT LESS THEN 50, PER IMC 602.2.1. 1.4 SEAL ALL TRANSVERSE JOINTS FOR DUCTWORK WITH STATIC PRESSURE BETWEEN 1/2 INCHES AND 2 INCHES. DUCTWORK WHICH IS DESIGNED TO OPERATE AT PRESSURES ABOVE 1/2 WATER COLUMN SHALL BE SEALED IN ACCORDANCE WITH STANDARD RS-7. 1.5 ALL DUCT GAUGES PER SMACNA, IMC 603-4. 1.6 ALL DUCT SUPPORTS PER SMACNA, IMC 603-10. 1.7 ATTACH DIFFUSERS AND GRILLES TO T-BAR PER WA STATE a LOCAL CODES. 1.8 BALANCING DAMPERS ARE TO BE INSTALLED ON ALL BRANCH DUCTS OR DIFFUSERS. INSULATION 2.1 INSULATE OR LINE DUCTWORK PER WA. STATE ENERGY AND MECHANICAL CODES. 2.2 INSULATE REFRIGERANT & CONDENSATE PIPING PER STATE 8 LOCAL ENERGY CODES. GENERAL CONTRACTOR 3.1 GENERAL CONTRACTOR TO PROVIDE AND CUT OPENINGS FOR ALL ROOFTOP, CEILING, FLOOR, AND WALL PENETRATIONS, INCLUDING WEATHERPROOF SEALING AND FIRE PROOF LININGS PER IMC & IBC. 3.2 GENERAL CONTRACTOR TO VERIFY PENETRATION LOCATION AND DIMENSIONS WITH ERL BEFORE FRAMING OPENINGS. 3.3 GENERAL CONTRACTOR TO PROVIDE ALL DEMOLITION, PATCHING, AND PAINTING AS REQUIRED FOR MECHANICAL WORK. 3.4 GENERAL CONTRACTOR TO PROVIDE ADEQUATE STRUCTURAL SUPPORT AS REQUIRED FOR MECHANICAL WORK. 3.5 GENERAL CONTRACTOR TO PROVIDE ADEQUATE ENGINEERING AS REQUIRED FOR MECHANICAL WORK. 3.6 GENERAL CONTRACTOR TO PROVIDE SERVICE ACCESS PER CODE TO ALL MECHANICAL EQUIPMENT. 3.7 GENERAL CONTRACTOR TO LEVEL ALL FACTORY CURBS PROVIDED BY ERL PROVIDE ALL CANT STRIPS AND CURB INSULATION, AND SEAL AGAINST LEAKS. 3.8 GENERAL CONTRACTOR TO PROVIDE ALL CUTTING AND PATCHING OR T-BAR CEILING AS REQUIRED FOR HVAC INSTALLATION. 3.9 GENERAL CONTRACTOR TO PROTECT ALL OPENINGS THROUGH FLOORS PROVIDED FOR DUCTWORK INSTALLATION IN ACCORDANCE WITH TABLE 601 OF INTERNATIONAL BUILDING CODE, WHERE REQUIRED BY SECTION 707 OF IBC. ELECTRICAL 4.1 ERL TO INSTALL ALL LOW VOLTAGE CONTROL WIRING, CONDUIT WILL BE PROVIDED BY ELECTRICAL CONTRACTOR. 4.2 ELECTRICAL CONTRACTOR TO PROVIDE ALL ELECTRICAL CONNECTIONS, DISCONNECTS, AND STARTERS FOR MECHANICAL EQUIPMENT. 42 ELECTRICAL CONTRACTOR TO VERIFY EQUIPMENT SIZES, LOADS AND LOCATIONS, WITH ERL MECHANICAL PLAN AND WITH FIELD LOCATIONS. 4.4 ELECTRICAL CONTRACTOR TO INTERLOCK BATHROOM EXHAUST FANS WITH LIGHT SWITCH. 4.5 ERL TO PROVIDE 7-DAY NIGHT SETBACK, PROGRAMMABLE TYPE T-STAT WITH CAPABILITY OF 5°F DEADBAND. 4.6 ERL TO VERIFY FINAL LOCATION OF THERMOSTAT WITH CUSTOMER. 4.7 ELECTRICAL CONTRACTOR TO PROVIDE ELECTRICAL GCFI OUTLET WITHIN 25 FT OF EACH PIECE OF MECHANICAL EQUIPMENT. PLUMBING 5.1 PLUMBING CONTRACTOR TO FURNISH AND INSTALL ALL GAS PIPING FOR MECHANICAL EQUIPMENT PER CODE. 5.2 PLUMBING CONTRACTOR OFFSETS VENTS 10 FEET MINIMUM FROM ALL HVAC FRESH AIR INTAKES OR 3' ABOVE HIGHEST POINT OF INTAKE, IMC 401.4.1 5.3 CONDENSATE DRAINS FROM RTU BY ERL TO DRAIN WITHIN 12" OF UNIT. CONDENSATE DRAINS FOR AIR HANDLERS BY PLUMBER. ENERGY CODE COMPLIANCE 6.1 THE SUPPLY HEATING AND COOLING ENERGY TO EACH ZONE SHALL BE CONTROLLED BY INDIVIDUAL THERMOSTATIC CONTROLS CAPABLE OF RESPONDING TO TEMPERATURE WITHIN THE ZONE. AT MINIMUM, EACH FLOOR SHALL BE CONSIDERED A ZONE. 6.2 OUTDOOR AIR SUPPLY, EXHAUST OPENINGS AND RELIEF OUTLETS SHALL BE PROVIDED WITH CLASS IA MOTORIZED DAMPERS WHICH CLOSE AUTOMATICALLY WHEN THE SYSTEM IS OFF PER WSEC SECTION C403.2.4.3. MECHANICAL CODE COMPLIANCE 7.1 WHERE REQUIRED PROVIDE AUTOMATIC SHUTOFF ACTIVATED BY SMOKE DETECTORS IN EACH SYSTEM DELIVERING HEATING OR COOLING AIR IN EXCESS OF 2000 CFM. DETECTORS SHALL BE LOCATED IN THE MAIN RETURN AIR PER IMC 606. WA2015 1 �.. %. _^2•, ,_D FC u 't :ct leaf Otu'rbirg L'J (..swig C._j of Tv :'r.7a Can^lON CO - or ` 12:.0 City rtV BUlLl • RECEIVED CITY OF TJKWILA SEP 2f 2018 PERMIT CENTER Mi9- oozy SYMBOL LEGEND NOTE: NOT ALL SYMBOLS SHOWN ON THIS LEGEND MAY PERTAIN TO THIS PROJECT. RECTANGULAR DUCT IOeX20" ROUND DUCT IO'0 I I ■I FLEXIBLE DUCT M►ft SUPPLY DUCT SECTION RETURN DUCT SECTION �; 0 EXHAUST DUCT SECTION SUPPLY DIFFUSER `a' RETURN/EXHAUST GRILLE 7 SIDEWALL DIFFUSER S CEILING MOUNTED EXHAUST FAN INLINE FAN E=IGI Q MANUAL VOLUME DAMPER II ZONE DAMPER r- J U MOTORIZED DAMPER M e FIRE SMOKE DAMPER (120V POWER REQ.) - 10-- FIRE DAMPER OTHERMOSTAT ®D SMOKE DETECTOR SO SENSOR Rnl EQUIPMENT TAG CD -I DIFFUSER/GRILLE TAG 250 CFM UNDER CUT DOOR 0 ROT namn d9i, MO,IO PROPERTY CFWEIT flSTYW9100I1e5, PRIOR WRITTBI6fEM RuRralm eN Crt6K M1 ROMS ,®,rm. TI.PW,WOAf051®[MO.. WS VMGE OIIS b PRSOPTEDD new AK NO OWL Yp W M TMt VUNbPRW.110Y LLC NO OTT TB! Of 9WLI! SOLD. RSfl OI O1,OWY@I®1MM IT1W OF MO MROR RT1 ODI.OnTATOM 10 LY9fi®I n[. YEI9LCCTM:T WIMTIE MOVE MMIIEQ 9WLC016TO0E CONCISE MUM OF ACCPFIAI a °Filet a[51F1cTiIDML .t ts Evergreen Refrigeration HVAC 727 SOUTH KENYON STREET EVERGRL954R2 SEATTLE, WASHINGTON 98108 PHONE: (206)-763-1744 www.evergreenhvac.com ENGINEERS STAMP HERE SCHOFIELD SHELL TI 16915 SOUTHCENTER PKWY TUKWILA, WA 98188 2 0 W 0 0 PERMIT DATE: SET 9/21/18 ISSUED FOR CONSTRUCTION DATE: ---- AS BUILT DATE ---- SCHOFIELD SHELL TI COVER `' - DWG BY: JV CKD BY: MG/AF JOB NO.: 518295 SHEET: MOO1 CD -I 135 CFM . t or S CD S WV //- NO WORK IN THIS AREA . . 0 HVAC PLAN 4" ORYFR VFNT TO ROOF NO WORK IN THIS AREA - NO WORK IN THIS AREA SUITE 4 NO WORK IN THIS AREA DROPS FROM RTU-1 1R" IIP TO ROOF HOOD RH-1 1A" IIP TO INTAKE HOOD IH - 1 18' CG-I E V a RT CG-I 100 CFM CD -I 215 CFM iNO WORK IN THIS AREA CO-1.1.1 laitivits 100 CFM•. .., ... , ir 1n in CD- Zr MI 20 C 47 MO MI 41 • • nig rritwire ob. toot wire. I I I 8' CD -I 215 CFM 16' i128.111 CD -I 215 CFM Off Ii CD -I 380 CFM 21•00 CD -I 380 CFM CD -I 380 CFM 16' 10 CD -I 50 CFM NO WORK IN THIS AREA CD -I 40 CFM CG-I 6" CD -I 215 CFM 12" CD -I 215 CFM • dIS 16" CD -I 125 CFM CD -I 215 CFM SCALE-1/4%1' NO WORK IN THIS AREA NO WORK IN THIS AREA EXPIRED DEc 04 2019 OP. • till o ICC _ g I 41 1 r, r c:v at rufrveill Let 7 '. RECEIVED CITY OF TUKWILA SEP 2 6 2018 PERMIT CENTER Par PL21.191ED. MI Mail MID AOMIGINCOS PROPORY OF EVO0J3311tORGOIA11001 OISTRUIUTED TO °TISK PRIOR WM11111 0316017 10162.411011 U.C. RIGHTS PESIVID. re MOVING /JO seratme, ma; IMPRIS0111:01100ST An PM WALL WYO. TIC (If, 10 MT That Of MILL 11! MU% RS& OA alleitWISt MD WTIOUTIIE OF MID APNtriPWTI 0:1•IPPISTA1OPI TO FraGIVOI YHA CONTACT 011111 TIC MOVE ORMINGS OR CONSTITUTE COICLISITE BTIONCE Or. ACCWIANCE OF bee 551301:KATIO16 91O1L R15110171016. IS 1101/4 * Evergreen 111 Refrigeration & HVAC -.....rap, _ — — 727 SOUTH KENYON STREET EVERGRL954R2 SEATTLE, WASHINGTON 98108 PHONE: (206)-763-1744 www.evergreenhvac.com ENGINEERS STAMP HERE \Qwi a v a 1011 HVAC ROOF PLAN fat SCALE: I/4"=1' DEC 04 MI Ml8eoiaq Chi of Tu.trt'aa L:::;L , LI:iT RECEIVED CITY OF TUKWILA SEP262018 PERMIT CENTER NOT iW191m 05101 NC MLWmIIIS Illortin OF npjTmlo MOOR IIMT61 NACCEPATp SIIOCATmMSMYLCOMAnNlT ALL MMi'Raflm. THE OIIMN0M09HDI Mna WS. IpM®O®TMTffiY AR AIM 9W1 MIYMM CYMMiMB1 Pfl INI IIG. ND MR TIRE OF SWLLE O11116. SIO, PLIBIZtle, Of I COMM OE USED Winaltne CO16017 Oi NO ARPOPRIAll COMPOISTATION TO O6mMm1 YC. VIO& CONDO M1111 M MOW CNMINdOR ftl1OI6M! & Ia OF WWTMQ OF TAM itinCTIONs it, tsEvergreen 3 Refrigeration HVAC fv 727 SOUTH KENYON STREET EVERGRL954R2 SEATTLE, WASHINGTON 98108 PHONE: (206)-763-1744 www.evergroenhvac.com ENGINEER'S STAMP HERE ROOF PLAN SCHOFIELD SHELL TI 16915 SOUTHCENTER PKWY TUKWILA, WA 98188 REV. DATE DESCRIPTION PERMIT DATE: 9/21/18 SET ISSUED FOR CONSTRUCTION DATE: --- ❑ AS BUILT DATE: ---- ❑ SCHOFIELD SHELL TI ROOF PLAN DWG BY: JV CKD BY: MG/AF JOB NO.: 518295 SHEET: M501