Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M18-0129 - TUKWILA SCHOOL DISTRICT / ADMINISTRATION - MINI SPLIT SYSTEM
TUKWILA SCHOOL DISTRICT- ADMIN 4640 S 144 ST BLDG 3 M18-0129 Parcel No: Address: -\ City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov 1523049108 4640 S 144TH ST BLDG 03 MECHANICAL PERMIT Project Name: TUKWILA SCHOOL DISTRICT - ADMIN Permit Number: M18-0129 Issue Date: 10/22/2018 Permit Expires On: 7/6/2019 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: TUKWILA SCHOOL DISTRICT 4640 S 144TH ST, TUKWILA, WA, 98168 JIM THOMAS W/ MCKINSTRY CO LLC 5005 THIRD AVE S , SEATTLE, WA, 98134 MCKINSTRY CO LLC (CONSTRUCTION) PO BOX 24567 , SEATTLE, WA, 98134 MCKINCL942DW Phone: (206) 763-4819 Phone: (206) 762-3311 Expiration Date: 3/16/2020 DESCRIPTION OF WORK: INSTALL MINI SPILT SYSTEM. INSTALL ONE RETURN GRILLE AND ASSOCIATED DUCT WORK. Valuation of Work: $8,655.00 Type of Work: NEW Fuel type: ELECT Fees Collected: $326.96 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: 125 Sewer District: VALLEY VIEW,TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Date: r'Qf 1 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. SignatureLIA Date: 1/877/7 Print Name: PTL -f\ J -4C $` Qy'`1Y10 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: <NONE> PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1800 MECHANICAL FINAL 1800 MECHANICAL FINAL 0701 ROUGH -IN MECHANICAL 0701 ROUGH -IN MECHANICAL Parcel No: Address: City of Tukwila f Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 1523049108 Permit Number: M18-0129 4242 S 144TH ST BLDG 1 Project Name: TUKWILA SCHOOL DISTRICT - ADMIN Issue Date: 10/22/2018 Permit Expires On: 4/20/2019 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: TUKWILA SCHOOL DISTRICT 4640 S 144TH ST, TUKWILA, WA, 98168 JIM THOMAS W/ MCKINSTRY CO LLC 5005 THIRD AVE S , SEATTLE, WA, 98134 MCKINSTRY CO LLC (CONSTRUCTION) PO BOX 24567 , SEATTLE, WA, 98134 MCKINCL942DW 1// Phone: (206) 763-4819 Phone: (206) 762-3311 Expiration Date: 3/16/2020 DESCRIPTION OF WORK: INSTALL MINI SPILT SYSTEM. INSTALL ONE RETURN GRILLE AND ASSOCIATED DUCT WORK. Valuation of Work: $8,655.00 Type of Work: NEW Fuel type: ELECT Fees Collected: $326.96 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: 125 Sewer District: VALLEY VIEW,TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Date: 1 0--a d 4 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: �t Print Name: % k. A ,&Jk » L4- -ki-vvV Date: %7cc+ 2019 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: <NONE> PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1800 MECHANICAL FINAL 0701 ROUGH -IN MECHANICAL t CITY OF TUKW1,, Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. M ( " Q psi Project No. Date Application Accepted: l Date Application Expires: 3-03 (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION King Co Assessor's Tax No.: 1523049108 Site Address: 4242 S 144th St Suite Number: New Tenant: Tenant Name: Tukwila School District Administration Bldg TI PROPERTY OWNER Name: Jim Thomas w/ McKinstry Co LLC Name: Tukwila School District City: Seattle State: WA Zip: 98134 Address: 4242 S 144th St Zip: 98134 City: Tukwila State: WA Zip: 98134 CONTACT PERSON — person receiving all project communication Name: Jim Thomas w/ McKinstry Co LLC Address: 5005 3rd Ave S City: Seattle State: WA Zip: 98134 City: Seattle State: WA Zip: 98134 Phone: (206) 762-3311 Fax: (206) 762-2624 Email: permits@mckinstry.com Floor: 1st ❑ Yes ®..No MECHANICAL CONTRACTOR INFORMATION Company Name: McKinstry Co LLC Address: 5005 3rd Ave S City: Seattle State: WA Zip: 98134 Phone: (206) 762-3311 Fax: (206) 762-2624 Contr Reg No.: MCKINCL942DW Exp Date: 03/16/2020 Tukwila Business License No.: BUS -0994320 Valuation of project (contractor's bid price): $ 8,655 Describe the scope of work in detail: Install mini split system. Install one return grille and associated duct work. Use: Residential: New ❑ Replacement ❑ Commercial: New Replacement ❑ Fuel Type: Electric 12I Gas ❑ Other: H:\Applications\Forms-Applications On Line\2016 Applications\Mechanical Permit Application Revised I-4-16.docx Revised: January 2016 bh Page 1 of 2 / \. Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Residential, Nighttime Furnace >100k btu Industrial Floor furnace 55 dB(A) Suspended/wall/floor mounted heater 57 dB(A) Appliance vent Commercial Repair or addition to heat/refrig/cooling system 1 Air handling unit 65 dB(A) <10,000 cfm 60 dB(A) Unit Type Qty Air handling unit Residential, Nighttime >10,000 cfm Industrial Evaporator cooler 55 dB(A) Ventilation fan connected to single duct 57 dB(A) Ventilation system Commercial Hood and duct 1 Incinerator — domestic 65 dB(A) Incinerator — comm/industrial 60 dB(A) I .4 Unit Type Qty Fire damper Residential, Nighttime Diffuser Industrial Thermostat 55 dB(A) Wood/gas stove 57 dB(A) Emergency generator Commercial Other mechanical equipment 1 60 dB(A) 65 dB(A) Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-10PM, Monday through Friday and 8AM-10PM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: • Warning devices; • Construction and property maintenance during the daytime hours (7am-lOpm); • Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING WNE R AUTHORIZED `A ENT ` Signature: ��i1Q-Ww �/ AY/ X C! Cr Date: 10/03/2018 Print Name. im Thomas w/ McKinstry Co LLC Day Telephone: (206) 762-3311 Mailing Address: 5005 3rd Ave S Seattle WA 98134 CityState Zip H:\Applications\Forms-Applications On Line12016 Applications\Mechanical Permit Application Revised 1-4-16.docx Revised: January 2016 bh Page 2 of 2 1 ti DESCRIPTIONS ACCOUNT QUANTITY PAID PermitTRAK $460.12 M18-0129 Address: 4242 S 144TH ST BLDG 1 Apn: 1523049108 $326.96 Credit Card Fee $9.52 Credit Card Fee R000.369.908.00.00 0.00 $9.52 MECHANICAL $305.23 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $211.03 PLAN CHECK FEE R000.322.102.00.00 0.00 $61.05 TECHNOLOGY FEE $12.21 TECHNOLOGY FEE R000.322.900.04.00 0.00 $12.21 PG18-0121 Address: 4242 5 144TH ST BLDG 1 Apn: 1523049108 $133.16 Credit Card Fee $3.88 Credit Card Fee R000.369.908.00.00 0.00 $3.88 PLUMBING $124.31 PERMIT FEE R000.322.100.00.00 0.00 $66.30 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PLAN CHECK FEE R000.322.103.00.00 0.00 $24.86 TECHNOLOGY FEE $4.97 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R15534 R000.322.900.04.00 0.00 $4.97 $460.12 Date Paid: Wednesday, October 03, 2018 Paid By: JIM THOMAS Pay Method: CREDIT CARD 036855 Printed: Wednesday, October 03, 2018 9:45 AM 1 of 1 / I =� SYSTEMS Page 2 of 2 CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA Date: 10/03/2018 09:44:06 AM CREDIT CARD SALE VISA CARD NUMBER: **********5178 K TRAN AMOUNT: $460.12 APPROVAL CD: 036855 RECORD #: 000 CLERK ID: Bill Thank you! Customer Copy https://classic.convergepay.com/V irtualMerchant/transaction.do?dispatchMethod=printTra... 10/3/2018 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: 1 4)I �}- hIS'Iic-T Type of Inspection: _ tx,44AwA F J,4 -L Address: q1b1to 6 jj11 rFI &r Date Called: Special Instructions:2 )4 03 Date Wanted: i - f b- i l p.m. Requester: 40" / Phone No: 2Qg 34& 8-7 1 fOL� Approved per applicable codes. Corrections required prior to approval. MMENTS: Iti,a34614.)tah-t— icPP9aaCA Inspector: Date: I—) (9, REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Project:����a Type of Inspection:� Address: /51 iipiz.. 6 /'fr� -sr- Date Called: Special Instructions:/ 461k0s fti Date Wanted: -19 a.rri: Requester Ant ciAtige. No: _ Phone 010, 39k, falle r Approved per applicable codes. `Corrections required prior to approval. COMMENTS: Inspector: Dateitipe7 r ! .1 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD M Retain a copy with permit 0 11 0/ INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pro�e�ct: ‘ c�jj�� % jjam�. ITAktAh JV1Ool Da T of Inspection: ,� t 1 ' 'r-C—L•1 Address:iqy Date Ca d:4441-2-61 Special Instructions: , .}1 if * ---, / IAO Date Wanted: (‘— fs.— 201 a.m: p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: -_4 z o cif riCi✓ --o rri C /F is' .4)67-moiu — (56(-- I -1 11E SIC 7- ev i-Doc,A tA,U 1 As7291..' % iNDoe, UN R I L -L' coitJi.IUSf}-7X /1,b7- / 796-773-1-1-gb , Inspector: Date: /7- 8--/6 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. JOHNSON BARROW Seattle — p. (206) 284-1476 2203 23rd Ave S. Seattle, WA 98144 Portland — p. (971) 717-7123 735 SW 20th PI. #230 Portland, OR 97205 Vancouver BC — p. (604) 506-7557 1520 McCallum Road #200 Abbotsford, BCV2S 8A3 Date: 8/23/2018 From: Johnson Barrow Project Name: Voltage To: McKinstry LG Mini Split Submittal Systems: ODU Tag ODU Model IDU Tag IDU Model Nominal Capacity Voltage CU -01 LSU180HSV5 AC -01 LSN180HSV5 18,000 BTU 208V/1PH Scope of Supply: • CU -01 o Outdoor Unit Powers Indoor Unit o Max Line Length = 114' / Max Elevation = 49' o EER = 12.6 / SEER = 21.5 o (1) Programmable Thermostat Exclusions: • Offloading, storage, access, rigging, and installation • Future fan coils equipment • Economizers, MERV filters MIYr oizq www.jbarrow,com REVIEWED FOR CODE COMPLIANCE APPROVED OCT 10 2018 • City of Tukwila BUILDING DIVISION RECEGVED C TY CSG' u ESCuC OCT 03 2018 PERM' MIATER Job Name/Location: Tukwila SD - Admin Building Date: 8/23/18 PO No.: Architect: GC: Tag #: AC-01/Cu-01 For:❑ File ❑ Resubmit ❑ Approval Other Engr: Mech: Rep: (Company) (Project Manager) LS180HSV5 Single Zone High Efficiency Standard Wall Mount Outdoor Unit (ODU) - LSU180HSV5, Indoor Unit (IDU) - LSN180HSV5 Performance: Cooling: Cooling Capacity (Min -Rated -Max) (Btu/h) SEER EER 3,070 "' 18,000 ' 29,515 21.5 12.58 SEER - Seasonal Energy Efficiency Ratio Heating: EER - Energy Efficiency Ratio Heating Capacity (Min -Rated -Max) (Btu/h) HSPF Max. Heating @ Indoor70°F DB Outdoor 19°F DB / 17°F WB Outdoor 6°F DB / 5°F WB Outdoor -3°F DB / -4°F WB 3,070 - 21,600 - 38,898 10.2 22,340 (103%) 19,300 (89%) 16,760 (77%) HSPF - Heating Seasonal Performance Factor Cooling Nominal Test Conditions: Indoor: 80°F DB / 67°F WB Outdoor: 95°F DB / 75°F WB Outdoor Unit: Heating Nominal Test Conditions: Indoor: 70°F DB / 60°F WB Outdoor: 47°F DB / 43°F WB MOP (A) MCA (A) Cooling / Heating Rated Amps (A) Compressor (A) Fan Motor (A) 20 13 9.85/9.85 9.6 0.25 MOP - Maximum Overcurrent Protection Total Power Input: MCA - Minimum Circuit Ampacity Cooling Power Input (kW) Heating Power Input (kW) 1.431 1.73 Piping: Liquid Line (in., O.D.) Vapor Line (in., O.D.) Additional Refrigerant (oz./ft.) Min. / Max. Pipe Length (ft.)2 Piping Length (no add'I refrig., ft.) Max. Elevation (ft.) 03/8 05/8 0.38 9.8 / 114.8 24.6 49.2 Controls Features: • 24 -Hour on/off timer • 4 -Way auto swing • Auto changeover • Auto restart • Jet cool/Jet heat • Built-in low ambi- ent standard, down to 14°F (cooling mode) Optional Accessories: • Condensate Sensor Connection • Inverter (variable speed compressor) • IDU compatible with Multi F ODUs • Smart Diagnosis • 3M Micro Filter • Self-cleaning indoor coil • Sleep mode • Cooling only function • Built-in Wi-Fi via Smart ThinQ app • Built-in base pan heater (9/12k; optional for 18k) ❑ MuItiSITET" CRC1 - PREMTBVCO ❑ AC Smart IV BACnet® Gateway - El MuItiSITE CRC1+ - PREMTBVC1 PBACNA000 ❑ MuItiSITE Comm. Mgr. - PBACNBTROA 0 ACP IV BACnet Gateway - PQNFB17C2 0 PI -485 - PMNFP14A1 0 Base Pan Heater for 18k - PQSH1201 ❑ Dry Contact - PDRYCB300 0 Low Ambient Wind Baffle Kit (Cooling 0 LonWorks® Gateway - PLNWKB100 to 0°F) - ZLABGPO2A For a complete list of available accessories, contact your LG representative. SB SZ HiEff Std WaIlMount L5180HSV5 2017 12 08 075605 For continual product development, LG reserves the right to change specifications without notice. - - - - - - - © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG Life's Good" is a registered trademark of LG Corp. /www.Ighvac.com Page 1 of 3 LG Life's Good Operating Range: Outdoor Unit: LG ayr- Cooling (°F DB) Heating (°F WB) 14"'118 -4 ^' +65 Indoor Unit: Cooling (°F WB) Heating (°F DB) 53-.75 60 - 86 Electrical: Power Supply (V'/Hz/O) 208-230/60/1 System Data: Refrigerant Type Refrigerant Control Refrigerant Charge (lbs.) ODU Sound Pressure (Cooling / Heating) (±3 dB[A])3 IDU Sound Pressure Cooling (H/M/L/Sleep) (±3 dB[A])3 Heating (H/M/L) (±3 dB[A])3 ODU Net / Shipping Weight (lbs.) IDU Net / Shipping Weight (lbs.) Heat Exchanger Coating R410A EEV 3.53 53 / 53 45/40/35/29 45 /40 /35 116.8 / 126.5 26.5 / 34.8 GoldFin•a Fan: ODU Type IDU Type Fan Speeds (Fan/Cool/Heat) Quantity (ODU + IDU) Motor/Drive ODU Max. Air Flow Rate (CFM) IDU Air Flow Cooling, Max/H/M/L (CFM) Heating, Max/H/M/L (CFM) Dehumidification (pts./hr.) Propeller Cross Flow 6/6/6 1+1 Brushless Digitally Controlled/Direct 2,119 706 / 530 / 477 / 371 706 / 547 / 494 / 371 5.5 Notes: . Acceptable operating voltage: 187V -253V. 2. Piping lengths are equivalent. 3. Sound Pressure levels are tested in an anechoic chamber under 150 Standard 3745. 4. All communication / connection (power) cable from the outdoor unit to the indoor unit is field supplied and is to be minimum four -conductor, 18 AWG, stranded, shielded or unshielded (if shielded, it must be grounded to the chassis of the outdoor unit only), and must comply with applicable local and national codes. 5. See Engineering Manual for sensible and latent capacities. 6. Power wiring cable size must comply with the applicable local and national code. 7. The indoor unit comes with a dry helium charge. 8. This data is rated 0 ft. above sea level, with 24.6 ft. of refrigerant line and a 0 ft. level difference between outdoor and indoor units. 9. Must follow installation instructions in the applicable LG installation manual. 10. Multi compatible 18k IDUs include socket adapters for refrigerant pipe connections with Multi F systems. BACnet• is a registered trademark of ASHRAE. LonWorks• is a trademark of Echelon Corporation. Wt. Intertek LUMP r�u. mi CERTIFIED., www.ahridirectory.org Undary Small AC AHRI Standard 210/240 Cerfif sonappfaz,.o,,lien Vie cenpkte systemis ixedratAHRt • Job Name/Location: Tukwila SD - Admin Building LS180HSV5 Single Zone High Efficiency Standard Wall Mount Outdoor Unit (ODU) - LSU180HSV5, Indoor Unit (IDU) - LSN180HSV5 1 153132 (383) „a;lln, 717 „ 718 (22) 31-112 (8W) C7r 8 C � m 111 Tag No.: AC-01/CU-01 LG Date: 8/23/18 tires Gent PO No • (ww) y3UI : iiun For continual product development, LG reserves the right to change specifications without notice. SB_SZ_HiEff_Std_WallMount LS180HSV5_2017_12_08_075605 © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG Life's Good” is a registered trademark of LG Corp. /www.Ighvac.com Page 2 of 3 • Job Name/Location: Tukwila SD - Admin Building LS180HSV5 Single Zone High Efficiency Standard Wall Mount Outdoor Unit (ODU) - LSU180HSV5, Indoor Unit (IDU) - LSN180HSV5 LGTag No.: AC-01/CU-01 Date: 8/23/18 Likes Go=PO No.: : [6-11/16(170)] Air Intake Hole (ww) you, : }gun 0 8 c 9. 0 0 ene Si lOJjuoO uoipanp moPe 1! 0 8 w 24132 (56) 8 v 13.19132(345) • 11.13/16(300) II II 2332 (53) I rT '' •L. l i jt -1116 (Tr7 ( 1 N !l �" of I N 1 R 1 -1116 (27) r 8 1119 • For continual product development, LG reserves the right to change specifications without notice. SB_SZ HiEff_Std_WaIlMount_LS180HSVS_2017_32_08_075605 © LG Electronics U.S.A., Inc., Englewood Cliffs, Ni. All rights reserved. "LG Life's Good" is a registered t•ademark of LG Corp. /www.Ighvac.com Page 3 of 3 Job Name/Location: Date: PO No.: Architect: For: 0 File 0 Resubmit 0 Approval 0 Other GC: Engr: Mech: Rep: Tag #: (Company) Pro'ect Mana_er PREMTBVCO MultiSITE CRC1 Remote Controller Electrical: Power Supply 12VDC power from indoor unit Surrounding Conditions: Temperature Operating Storage Humidity Storage 32-122 °F -22-122 °F 0-95% RH (non -condensing) Features: •Customizable color digital touch screen interface with Multilanguage support •BACnet® MS/TP •ZigBee Pro® Wireless network •Role based configuration (password protected) •Function code settings •Function Code Search Tool •Date and Time Display •Room temperature display •Operation - On/Off •Mode - Auto/Cool/Dry/Heat/Fan Only •Occupied cooling and heating temperature setpoints •Unoccupied cooling and heating temperature setpoints •7 day scheduling with mode •Fan speed - Auto/Low/Med/High/Power •Discharge vanes - Auto/Swing/Fixed •Static pressure installer setting •Error code display during unit or system malfunction Optional Accessories (sold separately): • PZCWRCG3 - Group Control Cable Kit • ZVRCZPWC1 - ZigBee Pro® Wireless Module3 • ZVRCZDWS1 - Wireless Door Window Switch' • ZVRCZCOC1 - Wireless Ceiling Mounted Occupancy Sensori 0 ZVRCZWOC1 - Wireless Wall Mounted Occupancy Sensori • PZCWRC1 - Extension Cable (for IDUs without terminal blocks) Notes: 1.Available functions/features may differ based on connected system. 2.Communication cable can be extended to a maximum of 164 feet. 3.Up to 10 door/window switches and ceiling/wall mounted sensors can be connected to the MultiSITE CRC1 Remote Controller. 4.Must follow installation instructions in the applicable LG installation manual. • R �° r f BACnet° is a registered trademark of ASHRAE LG Life's Good Connectivity: ®LG Occ Auto Heat a , MOM 'r 74° 7. LG Communications BACnet® MS/TP (default model) ZigBee Pro® wireless mesh network (P) (optional) 1 Channel/RS-485 V -Net Communications Cabling Specifications (V -Net): Type Size Length' 3 conductor, stranded, twisted, unshielded AWG 22-3 up to 164 ft AWG - American Wire Gage Unit Data: Dimensions 4.72" H x 3.39" W x 1.06" D Maximum Number of Indoor Units (per controller) 16 Typical Indoor Unit TERMINAL DESCRIPTION 4 (S) Tx - Rx Communication 5 (12V) 12 Volts DC 6 (G) Common 13 BACnet + 14 BACnet - 15 BACnet Common Note: Terminals 1, 2, 3, 16, 17, and 18 are unused. For continual product development, LG reserves the right to change specifications without notice. m LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG Life's Good" is a registered trademark of LG Corp. /www.lg-vrf.com SB_MuItiSITE_CRC1_Base_PREMTBVCO_04_17 Page 1 of 7 Job Name/Location: PREMTBVCO MuItiSITE CRC1 Remote Controller Dimensions: 4.72"H x 3.39"W x 1.06"D N ti .�_ 3.39" __.N. o a���9��9 LG Life's Good PO No.: Tag #: Date: a 0 a 0 a MN= 0 HNN For continual product development, LG reserves the right to change specifications without notice. m LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG Life's Good" is a registered trademark of LG Corp. /www.Ighvac.com SB_MultiSITE_CRC1_Base_PREMTBVCO_04_17 Page 2 of 7 Job Name/Location: PREMTBVCO MuItiSITE CRC1 Remote Controller Current Date Occupancy Status Occupied (Occ) or Unoccupied (Unocc) Room Indoor Temperature On/Off Tum the display on or off •LG Date: Tag #: LG Life's Good PO No.: Operation Mode Set Cool, Heat, Auto Cool, Auto Heat, Fan, Dry modes 0 e Note: Pressing and holding the Operation Mode icon takes the user to the Operation Mode page. Schedule Set weekly schedule Short Network Message Current Time Current Fan Speed Setting Operation Mode Status Up Arrow Raise Temperature Setpoint Down Arrow Lower Temperature Setpoint More Provides end user with access to less often used functions. Fan Speed Set fan to Slow, Low, Low -Med, Medium, Med-High, High, Power, Auto. (Available options depend on IDU model.) Note: Long -press of the Fan Speed button when in cooling mode triggers Power Cooling mode. If in Power Cooling mode, last airflow segment on top is lit in purple and the text changes from "Fan" to "Power Cool". This mode lasts for 30 minutes and then reverts back to the previous fan speed. For continual product development, LG reserves the right to change specifications without notice. 0 LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG Life's Good" is a registered trademark of LG Corp. /www.lg-vrf.com SB_MuItiSITE_CRCl_Base_PREMTBVCO_04_17 Page 3 of 7 Job Name/Location: PREMTBVCO MuItiSITE CRC1 Remote Controller LGDate: PO No Tag #: Life's Good MuItiSITE Remote Controller BACnet® MONITOR Points Al Object Name Object Type Monitor Points Description FilterAlarm_M BI Filter Alarm Status RoomTemp AV Room Temperature RoomHumidity AV Room Humidity (Only on model PREMTBVCI) ODUsilentMode_M 81 ODU Silent Mode Status SmartLoadCtrl_M 81 Smart Load Control Status OccStatus_M BI Occupancy Status MsgAddressLock_M BV Central Control Address Lock Status ZB_Zone1IEEEaddrs_M Al Zigbee Zonel Address ZB_Zone2lEEEaddrs_M Al Zigbee Zone2 Address ZB_Zone3lEEEaddrs_M Al Zigbee Zone3 Address ZB_Zone4lEEEaddrs_M Al Zigbee Zone4 Address ZB_Zone5lEEEaddrs_M Al Zigbee Zones Address ZB_Zone6lEEEaddrs_M Al Zigbee Zone6 Address ZB_Zone7lEEEaddrs_M Al Zigbee Zone7 Address ZB_Zone8lEEEaddrs_M Al Zigbee Zone8 Address ZB_Zone9lEEEaddrs_M Al Zigbee Zone9 Address ZB_Zone10IEEEaddrs_M Al Zigbee Zonel 0 Address CurrentErrorCode_M Al Current Error Code PreviousErrorCode_M AV Previous Error Code ErrorCode3_M AV Error Code3 ErrorCode4_M AV Error Code4 ErrorCode5_M AV Error Code5 ErrorCode6_M AV Error Code6 ErrorCode7_M AV Error Code7 ErrorCode8_M AV Error Code8 ErrorCode9_M AV Error Code9 ErrorCodelO_M AV Error Code10 OldestErrorCode_M Al Oldest Error Code FilterRemainTime_M Al Filter Time Remaining (Hours) PipelnTemp_M Al Pipe In Temperature PipeOutTemp_M Al Pipe Out Temperature MiddlePipeTemp_M Al Middle Pipe Temperature ODUgivenAddrs_M Al Assigned address by Outdoor Unit ZB_NetworkStatus_M MI Zigbee Network Status ZB_LowBattAlarm BV Global Zigbee Battery Sensor Alarm Monitor points continued on next page Notes: Available functions/features may differ based on the connected system. For continual product development, LG reserves the right to change specifications without notice. 0 LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG Life's Good" is a registered trademark of LG Corp. /www.Ighvac.com SB_MultISITE_CRC1_Base_PREMTBVCO_04_17 Page 4 of 7 Job Name/Location: PREMTBVCO MuItiSITE CRC1 Remote Controller • Tag #: LGDate: Life's Good PO No.: MuItiSITE Remote Controller BACnet® MONITOR Points — continued v Object Name Object Type Monitor Points Description ZB_ZonelStatus_M MI Zigbee Zone1 Status ZB_Zone2Status_M MI Zigbee Zone2 Status ZB_Zone3Status_M MI Zigbee Zone3 Status ZB_Zone4Status_M MI Zigbee Zone4 Status ZB_Zone5Status_M MI Zigbee Zone5 Status ZB_Zone6Status_M MI Zigbee Zone6 Status ZB_Zone7Status_M MI Zigbee Zone7 Status ZB_Zone8Status_M MI Zigbee Zone8 Status ZB_Zone9Status_M MI Zigbee Zone9 Status ZB_ZonelOStatus M MI Zigbee ZonelO Status ZB_Zonel BattStatus_M MI Zigbee Zone1 Battery Status ZB_Zone2BattStatus_M MI Zigbee Zone2 Battery Status ZB_Zone3BattStatus_M MI Zigbee Zone3 Battery Status ZB_Zone4BattStatus_M MI Zigbee Zone4 Battery Status ZB_Zone5BattStatus_M MI Zigbee Zone5 Battery Status ZB_Zone6BattStatus_M MI Zigbee Zone6 Battery Status ZB_Zone7BattStatus_M MI Zigbee Zone7 Battery Status ZB_Zone8BattStatus_M MI Zigbee Zone8 Battery Status ZB_Zone9BattStatus_M MI Zigbee Zone9 Battery Status ZB_Zone10BattStatus_M MI Zigbee ZonelO Battery Status ZB_Zone1 PairingStatus_M MI Zigbee Zone1 Pairing Status ZB_Zone2PairingStatus_M MI Zigbee Zone2 Pairing Status ZB_Zone3PairingStatus_M MI Zigbee Zone3 Pairing Status ZB_Zone4PairingStatus_M MI Zigbee Zone4 Pairing Status ZB_Zone5PairingStatus_M MI Zigbee Zone5 Pairing Status ZB_Zone6PairingStatus_M MI Zigbee Zone6 Pairing Status ZB_Zone7PairingStatus_M MI Zigbee Zone7 Pairing Status ZB_Zone8PairingStatus_M MI Zigbee Zone8 Pairing Status ZB_Zone9PairingStatus_M MI Zigbee Zone9 Pairing Status ZB_Zonel OPairingStatus_M MI Zigbee Zone10 Pairing Status PipeTempCnfg_M MI Pipe Temperature Configuration Status (Supported or Unsupported) ODUstatus M MI Outdoor Unit Status ODUType_M MI Outdoor Type IDUType_M MI Indoor Unit Type MsgOverrideActive BV Override Status Notes: Available functions/features may differ based on the connected system. For continual product development, LG reserves the right to change specifications without notice. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG Life's Good" is a registered trademark of LG Corp. /www.Ighvac.com SB_MuItiSITE_CRC1_Base_PREMTBVCO_04_17 Page 5 of 7 Job Name/Location: PREMTBVCO MuItiSITE CRC1 Remote Controller Tag #: LG Date: Life's Good PO No.: MuItiSITE Remote Controller BACnet® CONTROL Points g Object Name Object Type Control Points Description BACnetComAddr AV BACnet Communication Address BACnetNetworkUnits MV SI or Imperial Setting TempUnits MV Temperature Units Setting DisplayTimeFormat MV Time Format Setting DisplayColor MV Color Display Setting DisplayUseStandbyScreen MV Standby Screen Setting DisplayLanguage MV Language Display Setting DisplayLowBacklight AV Display Backlight Setting (Low) DisplayShowOnOff MV Show or Hide On/Off Setting DisplayShowMode MV Show or Hide Mode Setting DisplayShowSchedule MV Show or Hide Schedule Setting DisplayShowMore MV Show or Hide More Setting DisplayShowSetTemp MV Show or Hide Set Temperature Setting DisplayShowSpaceTemp MV Show or Hide Space Temperature Setting DisplayShowFanSpeed MV Show or Hide Fan Speed Setting DisplayShowHumidity MV Show or Hide Humidity Setting (Only on model PREMTBVC1) ForceHighBacklight BV Force Backlight MsgShortScreenMsgTxt CharString Value Location Message (Displays message at bottom of screen) MsgLongScreenMsgTxt CharString Value Description Message (Displays message on main screen) FilterAlarmRelease BV Filter Alarm Reset ConfigPassword AV Configuration Password (Password protects Installer Settings) UserPassword AV User Password (Password protects all settings) IDUonOff MV Indoor Unit On/Off Setting SystemMode MV System Mode Setting FanSpeed MV Fan Speed Setting TempSenseLoc MV Temperature Sensing Location Setting CoolingSP AV Cooling Setpoint Setting HeatingSP AV Heating Setpoint Setting CoolingSPMax AV Cooling Maximum Setpoint Setting CoolingSPMin AV Cooling Minimum Setpoint Setting HeatingSPMax AV Heating Maximum Setpoint Setting HeatingSPMin AV Heating Minimum Setpoint Setting MinDeadband AV Minumum Deadband Setting Control points continued on next page Notes: Available functions/features may differ based on the connected system. For continual product development, LG reserves the right to change specifications without notice. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG Life's Good" is a registered trademark of LG Corp. /www.Ighvac.com SB_MultiSFTE_CRC1_Base_PREMTBVCO_04_17 Page 6 of 7 Job Name/Location: PREMTBVCO MuItiSITE CRC1 Remote Controller LG Date: Tag #: Lifes Good PO No.: MuItiSITE Remote Controller BACnet® CONTROL Points — continued 4 Object Name Object Type Control Points Description SingleSP AV Single Setpoint Setting SingleSetpointMax AV Single Setpoint Maximum Setting SingleSetpointMin AV Single Setpoint Minimum Setting AirflowUpDown MV Airflow Up/Down Setting AirflowLeftRight MV Airflow Left/Right Setting AirflowCircular MV Airflow Circular Setting SingleDualSP MV Single or Dual Setpoint Setting SingleSPdeadband MV Single Setpoint Deadband Setting CntrlrOccSensor MV On -board Occupancy Sensor Enable/Disable (Only on model PREMTBVCI ) ControllerMinOccOnTime MV Minumum Occupancy Time Delay MsgSetbackActive BV Setback Enable/Disable (Also displays message if setback is set to enable) SetbackMode MV Setback Mode Setting SetbackCoolingSP AV Cooling Setback Setpoint Setting SetbackHeatingSP AV Heating Setback Setpoint Setting SetbackFanSpeed MV Setback Fan Speed Setting OverrideCoolingSP AV Cooling Override Setpoint Setting OverrideHeatingSP AV Heating Override Setpoint Setting OverrideMode MV Mode Override Setting OverrideFanSpeed MV Fan Speed Override Setting OverrideTimer MV Timer Override Setting ZB_Zone1 SnsrType MV Zigbee Zonel Sensor Type Setting ZB_Zone2SnsrType MV Zigbee Zone2 Sensor Type Setting ZB_Zone3SnsrType MV Zigbee Zone3 Sensor Type Setting ZB_Zone4SnsrType MV Zigbee Zone4 Sensor Type Setting ZB_Zone5SnsrType MV Zigbee Zone5 Sensor Type Setting ZB_Zone6SnsrType MV Zigbee Zone6 Sensor Type Setting ZB_Zone7SnsrType MV Zigbee Zone7 Sensor Type Setting ZB_Zone8SnsrType MV Zigbee Zone8 Sensor Type Setting ZB_Zone9SnsrType MV Zigbee Zone9 Sensor Type Setting ZB Zonel OSnsrType MV Zigbee Zone10 Sensor Type Setting VTR815xAxxxx-250 Enumerated Value Reserved/Do Not Use DisplayLongScreenMsg BV Reserved/Do Not Use Notes: Available functions/features may differ based on the connected system. For continual product development, LG reserves the right to change specifications without notice. m LG Electronics U.S.A., Inc., Englewood Cliffs, M. All rights reserved. "LG Life's Good" is a registered trademark of LG Corp. /www.Ighvac.com SB_MuItiSITE_CRC1_Base_PREMTBVCO_04_17 Page 7 of 7 1' 1 PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M18-0129 DATE: 10/03/18 PROJECT NAME: TSD ADMINISTRATION BLDG SITE ADDRESS: 4242 S 144 ST X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: /kw c LO—erl Building Division m Public Works AlVk 4)/4 Fire Prevention Structural Planning Division ❑ Permit Coordinator n • PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 10/04/18 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required Fl Approved with Conditions ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) DUE DATE: 11/01/18 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire ❑ Ping 0 PW 0 Staff Initials: 12/18/2013 City of Tukwila REVISION SUBMITTAL Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: l (8( i9 Plan Check/Permit Number: ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # Revision # ) after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner ❑ Deferred Submittal # Project Name: '1"-CIL.6WC(C2 SCtO1 DtS+vPC4- AsivNin `r-1 Project Address: cu,' g0 .S [ ,t1(' Fh s1-/ 'r(,[ Ktyo 1. t (,ij t41- o, (6 Contact Person: A R t' t CP -e i(V ^y H— Phone Number: j 3O 3( S -'( (-66 Summary of Revision: �sid6eSS CinOtv\Q-e RE£zii(tD CITY OF T11KWI[ 4 PF. iT-CENTEP Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in TRAKiT on 1" -CJ 15 W:\Permit Center \Templates\Forms \Revision Submittal Forndoc Revised: August 2015 MCKINSTRY CO LLC Washington State Department of kj Labor & Industries r \ Home Espanol Contact Safety & Health Claims & Insurance 1 Search L&I Page 1 of 3 —7 [ ' A -Z [ride{ Help My 1.&1 Workplace Rights Trades.& Licensing MCKINSTRY CO LLC Owner or tradesperson Principals ALLEN, DEAN CHARLES, PARTNER/MEMBER Hagar, Joseph Donald, PARTNER/MEMBER PEDERSEN, JAMIE D, AGENT MOORE, DOUGLAS JAMES, PARTNER/MEMBER (End: 03/01/2018) ALLEN, DAVID EDWARD, PARTNER/MEMBER (End: 03/01/2018) TEPLICKY, JOSEPH WILLIAM, PARTNER/MEMBER (End: 03/01/2018) Doing business as MCKINSTRY CO LLC WA UBI No. 602 569 922 PO BOX 24567 SEATTLE, WA 98134 206-762-3311 KING County Business type Limited Liability Company License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. ... ............................... Meets current requirements. License specialties GENERAL License no. MCKINCL942DW Effective — expiration 03/16/2006— 03/16/2020 Bond WESTERN SURETY CO Bond account no. 929511574 $12,000.00 Received by L&I Effective date 09/02/2010 09/09/2010 Expiration date Until Canceled Insurance Travelers Indemnity Company Th $2,000,000.00 Policy no. VTC2KC05643B901IND14 Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602569922&LIC=MCKINCL942DW&SAW= 10/22/2018 MCK1NSTRY C.) LLC Received by L&I Effective date 11/15/2017 01/31/2014 Expiration date 01/31/2019 Insurance history Savings No savings accoui:ts during the previous 6 year period. Lawsuits against the bond or savings Cause no. - 15-2-00291-9 Complaint filed INSULATION SP CIALISTS INC Complaint date ; 12/16/2015 Dismissed .................... Complaint against bond(s) or savings 929511574 Complaint amount $229, 702.21 L&I Tax debts .I No L&I tax debts recorded for thiis contractor license during the previous 6 year period, but some debts may be recorded i.'j other agencies. License Violation: ' No license violatic as during the previous 6 year period. Workers' camp Do you know if the ')usiness has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID 706.165-00 Doing business as 3i MCKINSTRY CO Estimated workers reported N/A L&I account contact. (360)902-4817 Self Insured. This business is certified to cover its own workers' comp costs. No premiums due. Public Worts Strikes and Debarments 1• Verify the contractc is eligible to perform work on public works projects. Contractor Strike:: No strikes have b: an issued against this contractor. Contractors not a. 'owed to bid No debarments h: ;e been issued against this contractor. Workplace afety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 08/29/2018 No violations Inspection no. 317950323 Location 15500 Simons r, id north east Kenmore, WA 9r )28 Inspection results date 01/24/2017 Inspection no. 317943177 Location 3411 S. Union A a Tacoma, WA 98. )9 Under appeal, The results of the inspection are being challenged. Date of appeal 04/27/2017 Page 2 of 3 Inspection result date 09/10/2014 Violations Help us improve https://secure.lni Na.gov/verify/Detail.aspx?UBI=602569922&LIC=MCKINCL942DW&SAW= 10;'22/2018