HomeMy WebLinkAboutPermit M18-0133 - LOZANO LAW - EXHAUST FAN, GRD'S, DUCTWORK AND THERMOSTATSLOZANO LAW
16400 SOUTHCENTR PKWY
306
M18-0133
Parcel No:
Address:
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-438-9350
Web site: http://www.TukwilaWA.gov
MECHANICAL PERMIT
2623049021 Permit Number: M18-0133
16400 SOUTHCENTER PKWY Unit306 Issue Date: 10/23/2018
Permit Expires On: 4/21/2019
Project Name: LOZANO LAW
Owner:
Name:
Address:
Contact Person:
Name:
Address:
Contractor:
Name:
Address:
License No:
Lender:
Name:
Address:
RADOVICH PROPERTIES LLC
2835 82ND AVE SE STE S 1, MERCER
ISLAND, WA, 98040
JOHN MERRILL
6426 18TH ST E , FIFE, WA, 98406
MECHANICAL & CONTROL SRVCS INC
(GENERAL)
6426 18TH ST E , FIFE, WA, 98424
MECHACS962BT
Phone: (253) 926-9777
Phone: (253) 926-9777
Expiration Date: 2/26/2020
DESCRIPTION OF WORK:
INSTALL (1) NEW EXHAUST FAN. RELOCATE (4) GRD'S AND ASSOCIATED DUCTWORK PER PLAN. RELOCATE (4)
EXSITING THERMOSTATS.
Valuation of Work: $2,500.00
Type of Work: NEW
Fuel type: ELECT
Fees Collected: $238.53
Electrical Service Provided by: PUGET SOUND ENERGY
Water District: TUKWILA
Sewer District: TUKWILA
Current Codes adopted by the City of Tukwila:
International Building Code Edition:
International Residential Code Edition:
International Mechanical Code Edition:
Uniform Plumbing Code Edition:
International Fuel Gas Code:
2015
2015
2015
2015
2015
National Electrical Code:
WA Cities Electrical Code:
WAC 296-46B:
WA State Energy Code:
2017
2017
2017
2015
Permit Center Authorized Signature:
Date: [o'-3 --
I hearby certify that I have read and examined this permit and know the same to be true and correct. All
provisions of law and ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this
development permit and agree to the conditions attached to this permit.
Signature:
Print Name:
Date: /1/F.
This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if
the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: Work shall be installed in accordance with the approved construction documents, and any changes made
during construction that are not in accordance with the approved construction documents shall be
resubmitted for approval.
2: All permits, inspection record card and approved construction documents shall be kept at the site of work
and shall be open to inspection by the Building Inspector until final inspection approval is granted.
3: All construction shall be done in conformance with the Washington State Building Code and the
Washington State Energy Code.
4: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap
the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks,
wells, and other excavations. Final inspection approval will be determined by the building inspector based
on satisfactory completion of this requirement.
5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the
City of Tukwila Building Department (206-431-3670).
6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila
Permit Center.
7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an
approval of, any violation of any of the provisions of the building code or of any other ordinances of the City
of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other
ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction
documents and other data shall not prevent the Building Official from requiring the correction of errors in
the construction documents and other data.
8: ***MECHANICAL PERMIT CONDITIONS***
9: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila
Permit Center (206/431-3670).
10: Manufacturers installation instructions shall be available on the job site at the time of inspection.
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206) 438-9350
1800 MECHANICAL FINAL
0609 PIPE/DUCT INSULATION
0701 ROUGH -IN MECHANICAL
CITY OF TUKWILA
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.TukwilaWA.gov
�•
Mechanical Permit No.
vt g- ()E
Project No.
Date Application Accepted:
Date Application Expires:
1O—
4 -S -c9
(For office use only)
MECHANICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**please print**
SITE LOCATION
King Co Assessor's Tax No.: 2623049021
Site Address: 16400 SOUTHCENTER PARKWAY Suite Number: 306
LOZANO LAW
Tenant Name:
PROPERTY OWNER
Name:
RADOVICH PROPERTIES, LLC
Address:
City: Fife State: WA
City:
State: Zip:
CONTACT PERSON — person receiving all project
communication
Name: John Merrill
Address: 6426 18th St. E
Address: 6426 18th St. E
City: Fife State: WA
City: Fife State: WA
Zip: 98406
Phone: (253) 926-9777 Fax:. (253)
926-9222
Email: johnm@groupmcs.com
New Tenant:
Floor: 3
E Yes ❑ ..No
MECHANICAL CONTRACTOR INFORMATION
Company Name: Mechanical & Control Services
Address: 6426 18th St. E
City: Fife State: WA
Zip: 98406
Phone: (253) 926-9777 Fax: (253)
926-9222
Contr Reg No.: MECHACS926BT Exp Date: 01/30/2020
Tukwila Business License No.: 0997334
Valuation of project (contractor's bid price): $ 2,500
Describe the scope of work in detail:
INSTALL (1) NEW EXHAUST FAN. RELOCATE (4) GRD'S & ASSOCIATED DUCTWORK PER PLAN. RELOCATE (4)
EXISTING THERMOSTATS.
Use:
Residential: New ❑ Replacement ❑
Commercial: New ❑ Replacement ❑
Fuel Type: Electric LI Gas ❑ Other:
H:\Applications \Forms -Applications On Line \20I6 Applications\Mechanical Permit Application Revised 1-4-16.docx
Revised: January 2016
bh
Page 1 of 2
Indicate type of mechanical work being installed and the quantity below:
Unit Type
Qty
Furnace <100k btu
Residential, Nighttime
Furnace >100k btu
3
Floor furnace
4
Suspended/wall/floor
mounted heater
1
Appliance vent
Commercial
Repair or addition to
heat/refrig/cooling
system
47 dB(A)
Air handling unit
65 dB(A)
<10,000 cfrn
60 dB(A)
Unit Type
Qty
Air handling unit
Residential, Nighttime
>10,000 cfm
3
Evaporator cooler
4
Ventilation fan
connected to single duct
1
Ventilation system
Commercial
Hood and duct
47 dB(A)
Incinerator — domestic
65 dB(A)
Incinerator —
comm/industrial
60 dB(A)
Unit Type
Qty
Fire damper
Residential, Nighttime
Diffuser
3
Thermostat
4
Wood/gas stove
57 dB(A)
Emergency generator
Commercial
Other mechanical
equipment
47 dB(A)
60 dB(A)
65 dB(A)
Boiler/Compressor
QtY
0-3 hp/100,000 btu
3-15 hp/500,000 btu
15-30 hp/1,000,000 btu
30-50 hp/1,750,000 btu
50+ hp/1,750,000 btu
Noise:
Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is
created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed.
For more details, see TMC 8.22
District of Sound
Producing Source
District of Receiving Property
Residential, Daytime*
Residential, Nighttime
Commercial
Industrial
Residential
55 dB(A)
45 dB(A)
57 dB(A)
60 dB(A)
Commercial
57 dB(A)
47 dB(A)
60 dB(A)
65 dB(A)
Industrial
60 dB(A)
50 dB(A)
65 dB(A)
70 dB(A)
*Daytime means 7AM-10PM, Monday through Friday and 8AM-10PM, Saturday, Sunday and State -recognized holidays.
A few sounds are exempt from the noise code, including:
• Warning devices;
• Construction and property maintenance during the daytime hours (lam -1 Opm);
• Testing of backup generators during the day.
PERMIT APPLICATION NOTES -
Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the permit center to comply with current fee schedules.
Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing
and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OAUTHORIZED AGENT:
Signature:
Date: I 0 /6 //
Print Name: John Merrill Day Telephone: (253) 831-4446
Mailing Address: 6426 18th St. E
\Applications\Forms-Applications On Line\2016 Applications\Mechanical Permit Application Revised 1-4-16.docx
Revised: January 2016
bh
Fife WA 98406
City State Zip
Page 2 of 2
I \
RegisterRec
City of Tukwila
DESCRIPTIONS ( ACCOUNT
PermitTRAK
QUANTITY
PAID
$238.53
M18-0133 Address: 16400 SOUTHCENTER PKWY 308 Apn: 2623049021 $238.53
MECHANICAL $229.36
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
0.00
$33.15
PERMIT FEE
R000.322.100.00.00
0.00
$150.34
PLAN CHECK FEE
R000.322.102.00.00
0.00
$45.87
TECHNOLOGY FEE $9.17
TECHNOLOGY FEE
TOTAL FEES PAID BY RECEIPT: R15561
R000.322.900.04.00 0.00 $9.17
$238.53
Date Paid: Friday, October 05, 2018
Paid By: MECHANICAL & CONTROL SERVICES
Pay Method: CHECK 29916
Printed: Friday, October 05, 2018 1:32 PM 1 of 1
'7SYSTEMS
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
j1(g'- Of 33
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
P ect:
t L
Type of Inspection:
Petrosa
a- FFN
Address:
.
1/47 Seati.e,en4er MAIL.
Date Called:
Special Instructions:
Date Wanted:
AO- -
6
a.m.
p.m.
Requester:
Phone No:
VAApproved per applicable codes. Corrections required prior to approval.
COMMENTS:
MC ot rf1/43
Inspector3S
REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
INSPECTION RECORD
Retain a copy with permit
INS'' ION NO.
MIF -0/33
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
Project:
Lo7 10 i.
Type of Inspection:
Mpei,fx.x,.t c.,0,1_,
Z/00 cou A�sflet7L2..
)
structions:ll
Special In
9'r oa�`ji/-` AA,Requter:
"mAddress:
Dae
/0 - Z5• -.orr p.m.
I 01
Phone No:
206,-503 - /73o
NApproved per applicable codes. !_J Corrections required prior to approval.
COMMENTS: yr "` 3O/
Plezhotiliced-
Ybile;
tri- *TA'sw 4,;(--6(0
Date:
/o-zS--
REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
WVhiIJ F1I4merFit EZ®
VFNTII •T
Specification Submittal Data / Panasonic Ventilation F
Description:
Ventilating fan shall be low sone ceiling mount
rated for continuous operation. Fan shall
be ENERGY STAR® rated and certified by the
Home Ventilating Institute (HVI). Evaluated by
the Underwriters Laboratories and conform to
both UL and cUL standards,
Motor/Blower:
• Four -pole totally enclosed condenser AC
motor rated for continuous use.
• Fan ventilation rates shall be manually
adjustable for 80 or 110 CFM.
• Power Rating shall be 120 volts and 60 Hz.
• Fan shall be UL and cUL listed for tub/shower
enclosure when GEC' protected.
• Motor equipped with thermal cutoff fuse.
• Removable, permanently lubricated, plug-in
motor.
Housing:
• Rust proof epoxy and polyester resin coating,
26 gauge galvanized steel body.
• 4" diameter duct with optional 3" adapter
included.
• Built in backdraft damper.
• Articulating and expandable extension bracket
up to 24".
Grille:
• Attractive design using Poly Pro material.
• Attaches directly to housing with torsion springs.
Warranty:
• ALL Parts: For period of 3 years from the date
of the original purchase.
Architectural Specifications:
Ventilation fan shat be ceiling mount, ENERGY
STAR® rated with built-in speed selector. Select
from 80/110 CFM and no more than 0.3/0.8
sone as certified by the Home Ventilating
Institute (HVI) at 0.1 static pressure in inches
water gauge (w.g.) and with no less than 73/104
CFM and no more than 0.6/1.2 sone as certified
by HVI at 0.25 w,g, Power Consumption shall be
no greater than 21.1/26.5 watts at 0.1 w.g. and
20.7/26.4 watts at 0.25 w.g. ENERGY STAR®
rated with efficiency of no less than 3.8/4.2
CFM/watt at 0.1 w.g. and 3,5/4.0 CFM/watt at
0.25 w.g. Duct diameter shall be no less than 4"
(3" if using the included duct adapter). The motor
shall be totally enclosed, four pole condenser
type engineered to run continuously. Power
rating shall be 120v/60Hz. Housing material shall
be no less than 26 gauge galvanized steel with
rust proof epoxy and polyester resin coating.
Fan shall be UL and cUL listed for tub/shower
enclosure when GFCI protected. Fan can be
used to comply with ASHRAE 62.2, LEED,
ENERGY STAR® IAP, EarthCraft, California
Title -24, and WA Ventilation Code.
FV -08-1 1 VF5
3" or 4" Duct
See
REVIIEWEDt-OR
OSIDEttkirijinitZt
APPROVED
OCT 19 2018
City of Tukwila
BUI
Curves
Specifications:
Ventilation Fan
Characteristics
(HVI Certified Data)
WhisperFit'5 EZ FV -08-1 1 VF5
Static Pressure in inches w.g.
Air Volume (CFM)
MOWED
110 CFM Setting
FV -08-11 VF5
` - - v • lg
':
4"
0.1
110
Duct
0.25
104
3" Duct
0.1 0.25
100 88
4" Duct
0.1
80
Date: 1 0/5/1 8
3"
0.1
70
Duct
0.25
0.25
73
61
Noise (sones)
0.8
1.2
1.3
1.5
0.3
0.6
0.5 i 1.1
(___._
._.._____._.__.
i
Power Consumption (Watts)
.___..._______....._.....__._._. _.._.._...___........._
Energy Efficiency (CFM/Watt)
I
i
26.5
_ .....
4.2
26.4
_......_�....
4.0
26.4
3,9
25.9
21.1
3.8
20.7
3.5
20.9 20.3
3.5 3.2
___......_
3.5
I
Speed (RPM)
i
961
1179
1215
1369
848
1123
1005 i 1236
Current (amps)
I
0.23
0.23
0.22
0.22
0.18
0.17
0.17 i 0.17
MAX. Current (amps)
I
0.23
0.23
0.18
0.18
Power Rating (V/Hz)
ENERGY STAR rated
#
120/60
YES
120/60
YES
120/60
YES
120/60
YES
0.25, --Installed Performance
For complete Installation Instructions visit us.panasonic.com/ventfans
Model
Quantity
MOWED
Project:
FV -08-11 VF5
1
CITY OF TUKWILA
OCT 05 1U Id
PERMIT CENTER
Location: TUKWILA, WA
Architect:
Engineer:
Contractor: MCS
Submitted by: JJM
Date: 1 0/5/1 8
Panasonic Eco Solutions North America
Eco Products Division
Two Riverfront Plaza
Newark, NJ 07102
us.panasonic.comlventfans
(MN.) c I'l us
0
Ism
Panasonic
WherFit EZ®
vcuru �nnu ispcAu
Performance Curve FV -08-11 VF5 - 80 CFM
o, 0.70
0.60
o
N 0.50
aNi
a
y 0.40
0.30
0.20 •
0.10 •
0.00
0 10 20 30 40 50 60 70 80 90100
Airflow(CFM)
•- FV-08-11VF5
4" duct/80CFM
FV -08-11 VF5
3" duct/80CFM
•-• 4" 20ft duct
• • 4" 40ft duct
4" 60ft duct
4" 80ft duct
1— 4" 100ft duct
I • • • 3" 20ft duct
-- 3" 40ft duct
3" 60ft duct
i 3" 80ft duct
3" 100ft duct
FV -08-1 1 VF5
Performance Curve FV-08-11VF5 - 110 CFM
m 0.70 j FV-08-11VF5
3 / 4" duct/110CFM
u0.60 •.::....._............._gar...................1.......;......._...:.._................................... FV -08-1 iVFS
S 3" duct/110CFM
.a : , •- • 4" 20ft duct
N
0 50 ...._.......
N '4_ 4" 40ft duct
T.
7:;,(2
• • 4" 60ft duct
u •
0.40 •
y; 4" 80ft duct
0.30 ... — 4" 100ft duct3" 60ft duct
0.10 •0.00
-
0 20 40 60 80 100 120
Airflow(CFM)
Model
Quantity
Comments
Project:
FV -08-1 1 VF5
1
:
{
Location. TU KW I LA,__WA........._..._......._........__..._......_..._
Architect:
Engineer:
Contractor: MCS
Submitted by: JJM
Date: 10/5/18
Panasonic Eco Solutions North America
Eco Products Division
Two Riverfront Plaza
Newark, NJ 07102
us.panasonic.com/ventfans
VIcilLus
Panasonic
/
PLAl�pREVIEW/ROUTING SLIP
PERMIT NUMBER: M18-0133 DATE: 10/05/18
PROJECT NAME: LOZANO LAW
SITE ADDRESS: 16400 SOUTHCENTER PARKWAY
X Original Plan Submittal
Response to Correction Letter #
Revision # before Permit Issued
Revision # after Permit Issued
DEPARTMENTS:
Building Division
itty
Public Works n
Fire Prevention
Structural
Planning Division
❑ Permit Coordinator 111
PRELIMINARY REVIEW:
Not Applicable n
(no approval/review required)
DATE: 10/09/18
Structural Review Required
REVIEWER'S INITIALS: DATE:
n
APPROVALS OR CORRECTIONS: DUE DATE: 11/06/18
Approved
Corrections Required
n Approved with Conditions n
nDenied
(corrections entered in Reviews) (ie: Zoning Issues)
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg 0 Fire ❑ Ping 0 PW ❑ Staff Initials:
12/18/2013
MECHANICAL & CONTROL SRVCSIINC
Horne Espanol Contact
Safety & Health Claims & Insurance
Washington State Department of
ki Labor & Industries
!Search L&I
Page 1 of 3
A -Z index t-telp 1\iy ISA
Workplace Rights Trades & Licensing
MECHANICAL & CONTROL SRVCS INC
Owner or tradesperson
Principals
Hull, Travis Edward, PRESIDENT
Hunt, Ted Lamond, VICE PRESIDENT
HULL, ANGELA DAWN, SECRETARY
GROVER, HAROLD, VICE PRESIDENT
(End: 02/26/2010)
DICKSON, PAUL, TREASURER
(End: 02/26/2010)
Doing business as
MECHANICAL & CONTROL SRVCS INC
WA UBI No.
602 338 440
6426 18th St E
FIFE, WA 98424
253-926-9777
PIERCE County
Business type
Corporation
Governing persons
ANGELA
DAWN
HULL
TRAVIS EDWARD HULL;
License
Verify the contractor's active registration / license / certification (depending on trade) and any past violations.
Construction Contractor
License specialties
GENERAL
License no.
MECHACS962BT
Effective — expiration
01/30/2004— 02/26/2020
Bond
American Contractors Indem CO
Bond account no.
100239439
Active.
Meets current requirements.
$12,000.00
Received by L&I Effective date
02/10/2014 02/06/2014
Expiration date
Until Canceled
Bond history
Insurance
............
Continental Insurance Co
Policy no.
6023856626
$1,000,000.00
Help us improve
https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602338440&LIC=MECHACS962BT&SAW= 10/23/2018
MECHANICAL & CONTROL SRVCS INC
Received by L&I Effective date
01/18/2018 01/23/2018
Expiration date
01/23/2019
Insurance history
Savings
No savings accounts during the previous 6 year period.
Lawsuits against the bond or savings
No lawsuits against the bond or savIngs accounts during the previous 6 year period.
L&I Tax debts
No L&I tax debts are recorded for thus contractor license during the previous 6 year period, but some debts
may be recorded by other agencies.
License Violations
............_..... _.. ...
No license violations during the previous 6 year period.
Workers' comp
Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums.
This company has multiple workers' comp accounts.
Active accounts
L&I Account ID
539,805-00
Doing business as
MECHANICAL & CONTROL SERVICES
Estimated workers reported
Quarter 2 of Year 2018 "51 to 75 Workers"
L&I account contact
T5 / MELISSA VEST (360)902-5613 • Email: VESM235@Ini.wa.gov
Track this contractor 0
Account is current.
Public Works Strikes and Debarments
Verify the contractor is eligible to perform work on public works projects.
Contractor Strikes
..............................
No strikes have been issued against this contractor.
Contractors not allowed to bid
No debarments have been issued against this contractor.
Workplace safety and health
Check for any past safety and health -violations found on jobsites this business was responsible for.
Inspection results date
05/22/2013
Inspection no.
316579655
Location
13570 Bell -Red Rd
Bellevue, WA 98005
Inspection results date
02/26/2013
Inspection no.
316582154
Location
30 S Wenatchee Ave
Wenatchee, WA 98801
Inspection results date
02/21/2013
Inspection no.
Violations
Violations
Nc violations
Page 2 of 3
Help us improve
https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602338440&LIC=MECHACS962BT&SAW= 10/23/2018