HomeMy WebLinkAboutPermit M18-0133 - LOZANO LAW - EXHAUST FAN, GRD'S, DUCTWORK AND THERMOSTATSLOZANO LAW 16400 SOUTHCENTR PKWY 306 M18-0133 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 2623049021 Permit Number: M18-0133 16400 SOUTHCENTER PKWY Unit306 Issue Date: 10/23/2018 Permit Expires On: 4/21/2019 Project Name: LOZANO LAW Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: RADOVICH PROPERTIES LLC 2835 82ND AVE SE STE S 1, MERCER ISLAND, WA, 98040 JOHN MERRILL 6426 18TH ST E , FIFE, WA, 98406 MECHANICAL & CONTROL SRVCS INC (GENERAL) 6426 18TH ST E , FIFE, WA, 98424 MECHACS962BT Phone: (253) 926-9777 Phone: (253) 926-9777 Expiration Date: 2/26/2020 DESCRIPTION OF WORK: INSTALL (1) NEW EXHAUST FAN. RELOCATE (4) GRD'S AND ASSOCIATED DUCTWORK PER PLAN. RELOCATE (4) EXSITING THERMOSTATS. Valuation of Work: $2,500.00 Type of Work: NEW Fuel type: ELECT Fees Collected: $238.53 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Permit Center Authorized Signature: Date: [o'-3 -- I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: Date: /1/F. This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 4: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 8: ***MECHANICAL PERMIT CONDITIONS*** 9: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 10: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0701 ROUGH -IN MECHANICAL CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov �• Mechanical Permit No. vt g- ()E Project No. Date Application Accepted: Date Application Expires: 1O— 4 -S -c9 (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION King Co Assessor's Tax No.: 2623049021 Site Address: 16400 SOUTHCENTER PARKWAY Suite Number: 306 LOZANO LAW Tenant Name: PROPERTY OWNER Name: RADOVICH PROPERTIES, LLC Address: City: Fife State: WA City: State: Zip: CONTACT PERSON — person receiving all project communication Name: John Merrill Address: 6426 18th St. E Address: 6426 18th St. E City: Fife State: WA City: Fife State: WA Zip: 98406 Phone: (253) 926-9777 Fax:. (253) 926-9222 Email: johnm@groupmcs.com New Tenant: Floor: 3 E Yes ❑ ..No MECHANICAL CONTRACTOR INFORMATION Company Name: Mechanical & Control Services Address: 6426 18th St. E City: Fife State: WA Zip: 98406 Phone: (253) 926-9777 Fax: (253) 926-9222 Contr Reg No.: MECHACS926BT Exp Date: 01/30/2020 Tukwila Business License No.: 0997334 Valuation of project (contractor's bid price): $ 2,500 Describe the scope of work in detail: INSTALL (1) NEW EXHAUST FAN. RELOCATE (4) GRD'S & ASSOCIATED DUCTWORK PER PLAN. RELOCATE (4) EXISTING THERMOSTATS. Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement ❑ Fuel Type: Electric LI Gas ❑ Other: H:\Applications \Forms -Applications On Line \20I6 Applications\Mechanical Permit Application Revised 1-4-16.docx Revised: January 2016 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Residential, Nighttime Furnace >100k btu 3 Floor furnace 4 Suspended/wall/floor mounted heater 1 Appliance vent Commercial Repair or addition to heat/refrig/cooling system 47 dB(A) Air handling unit 65 dB(A) <10,000 cfrn 60 dB(A) Unit Type Qty Air handling unit Residential, Nighttime >10,000 cfm 3 Evaporator cooler 4 Ventilation fan connected to single duct 1 Ventilation system Commercial Hood and duct 47 dB(A) Incinerator — domestic 65 dB(A) Incinerator — comm/industrial 60 dB(A) Unit Type Qty Fire damper Residential, Nighttime Diffuser 3 Thermostat 4 Wood/gas stove 57 dB(A) Emergency generator Commercial Other mechanical equipment 47 dB(A) 60 dB(A) 65 dB(A) Boiler/Compressor QtY 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-10PM, Monday through Friday and 8AM-10PM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: • Warning devices; • Construction and property maintenance during the daytime hours (lam -1 Opm); • Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OAUTHORIZED AGENT: Signature: Date: I 0 /6 // Print Name: John Merrill Day Telephone: (253) 831-4446 Mailing Address: 6426 18th St. E \Applications\Forms-Applications On Line\2016 Applications\Mechanical Permit Application Revised 1-4-16.docx Revised: January 2016 bh Fife WA 98406 City State Zip Page 2 of 2 I \ RegisterRec City of Tukwila DESCRIPTIONS ( ACCOUNT PermitTRAK QUANTITY PAID $238.53 M18-0133 Address: 16400 SOUTHCENTER PKWY 308 Apn: 2623049021 $238.53 MECHANICAL $229.36 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $150.34 PLAN CHECK FEE R000.322.102.00.00 0.00 $45.87 TECHNOLOGY FEE $9.17 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R15561 R000.322.900.04.00 0.00 $9.17 $238.53 Date Paid: Friday, October 05, 2018 Paid By: MECHANICAL & CONTROL SERVICES Pay Method: CHECK 29916 Printed: Friday, October 05, 2018 1:32 PM 1 of 1 '7SYSTEMS INSPECTION NO. INSPECTION RECORD Retain a copy with permit j1(g'- Of 33 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 P ect: t L Type of Inspection: Petrosa a- FFN Address: . 1/47 Seati.e,en4er MAIL. Date Called: Special Instructions: Date Wanted: AO- - 6 a.m. p.m. Requester: Phone No: VAApproved per applicable codes. Corrections required prior to approval. COMMENTS: MC ot rf1/43 Inspector3S REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INS'' ION NO. MIF -0/33 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Lo7 10 i. Type of Inspection: Mpei,fx.x,.t c.,0,1_, Z/00 cou A�sflet7L2.. ) structions:ll Special In 9'r oa�`ji/-` AA,Requter: "mAddress: Dae /0 - Z5• -.orr p.m. I 01 Phone No: 206,-503 - /73o NApproved per applicable codes. !_J Corrections required prior to approval. COMMENTS: yr "` 3O/ Plezhotiliced- Ybile; tri- *TA'sw 4,;(--6(0 Date: /o-zS-- REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. WVhiIJ F1I4merFit EZ® VFNTII •T Specification Submittal Data / Panasonic Ventilation F Description: Ventilating fan shall be low sone ceiling mount rated for continuous operation. Fan shall be ENERGY STAR® rated and certified by the Home Ventilating Institute (HVI). Evaluated by the Underwriters Laboratories and conform to both UL and cUL standards, Motor/Blower: • Four -pole totally enclosed condenser AC motor rated for continuous use. • Fan ventilation rates shall be manually adjustable for 80 or 110 CFM. • Power Rating shall be 120 volts and 60 Hz. • Fan shall be UL and cUL listed for tub/shower enclosure when GEC' protected. • Motor equipped with thermal cutoff fuse. • Removable, permanently lubricated, plug-in motor. Housing: • Rust proof epoxy and polyester resin coating, 26 gauge galvanized steel body. • 4" diameter duct with optional 3" adapter included. • Built in backdraft damper. • Articulating and expandable extension bracket up to 24". Grille: • Attractive design using Poly Pro material. • Attaches directly to housing with torsion springs. Warranty: • ALL Parts: For period of 3 years from the date of the original purchase. Architectural Specifications: Ventilation fan shat be ceiling mount, ENERGY STAR® rated with built-in speed selector. Select from 80/110 CFM and no more than 0.3/0.8 sone as certified by the Home Ventilating Institute (HVI) at 0.1 static pressure in inches water gauge (w.g.) and with no less than 73/104 CFM and no more than 0.6/1.2 sone as certified by HVI at 0.25 w,g, Power Consumption shall be no greater than 21.1/26.5 watts at 0.1 w.g. and 20.7/26.4 watts at 0.25 w.g. ENERGY STAR® rated with efficiency of no less than 3.8/4.2 CFM/watt at 0.1 w.g. and 3,5/4.0 CFM/watt at 0.25 w.g. Duct diameter shall be no less than 4" (3" if using the included duct adapter). The motor shall be totally enclosed, four pole condenser type engineered to run continuously. Power rating shall be 120v/60Hz. Housing material shall be no less than 26 gauge galvanized steel with rust proof epoxy and polyester resin coating. Fan shall be UL and cUL listed for tub/shower enclosure when GFCI protected. Fan can be used to comply with ASHRAE 62.2, LEED, ENERGY STAR® IAP, EarthCraft, California Title -24, and WA Ventilation Code. FV -08-1 1 VF5 3" or 4" Duct See REVIIEWEDt-OR OSIDEttkirijinitZt APPROVED OCT 19 2018 City of Tukwila BUI Curves Specifications: Ventilation Fan Characteristics (HVI Certified Data) WhisperFit'5 EZ FV -08-1 1 VF5 Static Pressure in inches w.g. Air Volume (CFM) MOWED 110 CFM Setting FV -08-11 VF5 ` - - v • lg ': 4" 0.1 110 Duct 0.25 104 3" Duct 0.1 0.25 100 88 4" Duct 0.1 80 Date: 1 0/5/1 8 3" 0.1 70 Duct 0.25 0.25 73 61 Noise (sones) 0.8 1.2 1.3 1.5 0.3 0.6 0.5 i 1.1 (___._ ._.._____._.__. i Power Consumption (Watts) .___..._______....._.....__._._. _.._.._...___........._ Energy Efficiency (CFM/Watt) I i 26.5 _ ..... 4.2 26.4 _......_�.... 4.0 26.4 3,9 25.9 21.1 3.8 20.7 3.5 20.9 20.3 3.5 3.2 ___......_ 3.5 I Speed (RPM) i 961 1179 1215 1369 848 1123 1005 i 1236 Current (amps) I 0.23 0.23 0.22 0.22 0.18 0.17 0.17 i 0.17 MAX. Current (amps) I 0.23 0.23 0.18 0.18 Power Rating (V/Hz) ENERGY STAR rated # 120/60 YES 120/60 YES 120/60 YES 120/60 YES 0.25, --Installed Performance For complete Installation Instructions visit us.panasonic.com/ventfans Model Quantity MOWED Project: FV -08-11 VF5 1 CITY OF TUKWILA OCT 05 1U Id PERMIT CENTER Location: TUKWILA, WA Architect: Engineer: Contractor: MCS Submitted by: JJM Date: 1 0/5/1 8 Panasonic Eco Solutions North America Eco Products Division Two Riverfront Plaza Newark, NJ 07102 us.panasonic.comlventfans (MN.) c I'l us 0 Ism Panasonic WherFit EZ® vcuru �nnu ispcAu Performance Curve FV -08-11 VF5 - 80 CFM o, 0.70 0.60 o N 0.50 aNi a y 0.40 0.30 0.20 • 0.10 • 0.00 0 10 20 30 40 50 60 70 80 90100 Airflow(CFM) •- FV-08-11VF5 4" duct/80CFM FV -08-11 VF5 3" duct/80CFM •-• 4" 20ft duct • • 4" 40ft duct 4" 60ft duct 4" 80ft duct 1— 4" 100ft duct I • • • 3" 20ft duct -- 3" 40ft duct 3" 60ft duct i 3" 80ft duct 3" 100ft duct FV -08-1 1 VF5 Performance Curve FV-08-11VF5 - 110 CFM m 0.70 j FV-08-11VF5 3 / 4" duct/110CFM u0.60 •.::....._............._gar...................1.......;......._...:.._................................... FV -08-1 iVFS S 3" duct/110CFM .a : , •- • 4" 20ft duct N 0 50 ...._....... N '4_ 4" 40ft duct T. 7:;,(2 • • 4" 60ft duct u • 0.40 • y; 4" 80ft duct 0.30 ... — 4" 100ft duct3" 60ft duct 0.10 •0.00 - 0 20 40 60 80 100 120 Airflow(CFM) Model Quantity Comments Project: FV -08-1 1 VF5 1 : { Location. TU KW I LA,__WA........._..._......._........__..._......_..._ Architect: Engineer: Contractor: MCS Submitted by: JJM Date: 10/5/18 Panasonic Eco Solutions North America Eco Products Division Two Riverfront Plaza Newark, NJ 07102 us.panasonic.com/ventfans VIcilLus Panasonic / PLAl�pREVIEW/ROUTING SLIP PERMIT NUMBER: M18-0133 DATE: 10/05/18 PROJECT NAME: LOZANO LAW SITE ADDRESS: 16400 SOUTHCENTER PARKWAY X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: Building Division itty Public Works n Fire Prevention Structural Planning Division ❑ Permit Coordinator 111 PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 10/09/18 Structural Review Required REVIEWER'S INITIALS: DATE: n APPROVALS OR CORRECTIONS: DUE DATE: 11/06/18 Approved Corrections Required n Approved with Conditions n nDenied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire ❑ Ping 0 PW ❑ Staff Initials: 12/18/2013 MECHANICAL & CONTROL SRVCSIINC Horne Espanol Contact Safety & Health Claims & Insurance Washington State Department of ki Labor & Industries !Search L&I Page 1 of 3 A -Z index t-telp 1\iy ISA Workplace Rights Trades & Licensing MECHANICAL & CONTROL SRVCS INC Owner or tradesperson Principals Hull, Travis Edward, PRESIDENT Hunt, Ted Lamond, VICE PRESIDENT HULL, ANGELA DAWN, SECRETARY GROVER, HAROLD, VICE PRESIDENT (End: 02/26/2010) DICKSON, PAUL, TREASURER (End: 02/26/2010) Doing business as MECHANICAL & CONTROL SRVCS INC WA UBI No. 602 338 440 6426 18th St E FIFE, WA 98424 253-926-9777 PIERCE County Business type Corporation Governing persons ANGELA DAWN HULL TRAVIS EDWARD HULL; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. MECHACS962BT Effective — expiration 01/30/2004— 02/26/2020 Bond American Contractors Indem CO Bond account no. 100239439 Active. Meets current requirements. $12,000.00 Received by L&I Effective date 02/10/2014 02/06/2014 Expiration date Until Canceled Bond history Insurance ............ Continental Insurance Co Policy no. 6023856626 $1,000,000.00 Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602338440&LIC=MECHACS962BT&SAW= 10/23/2018 MECHANICAL & CONTROL SRVCS INC Received by L&I Effective date 01/18/2018 01/23/2018 Expiration date 01/23/2019 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savIngs accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for thus contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations ............_..... _.. ... No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. This company has multiple workers' comp accounts. Active accounts L&I Account ID 539,805-00 Doing business as MECHANICAL & CONTROL SERVICES Estimated workers reported Quarter 2 of Year 2018 "51 to 75 Workers" L&I account contact T5 / MELISSA VEST (360)902-5613 • Email: VESM235@Ini.wa.gov Track this contractor 0 Account is current. Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes .............................. No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health Check for any past safety and health -violations found on jobsites this business was responsible for. Inspection results date 05/22/2013 Inspection no. 316579655 Location 13570 Bell -Red Rd Bellevue, WA 98005 Inspection results date 02/26/2013 Inspection no. 316582154 Location 30 S Wenatchee Ave Wenatchee, WA 98801 Inspection results date 02/21/2013 Inspection no. Violations Violations Nc violations Page 2 of 3 Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602338440&LIC=MECHACS962BT&SAW= 10/23/2018