Loading...
HomeMy WebLinkAboutPermit M18-0139 - LINDAL CEDAR HOMES - VAV BOXES, SENSOR, DUCT LAYOUT, ETCLINDAL CEDAR HOMES 6840 FORT DENT WAY UNIT 200 M18-0139 Parcel No: Address: i \ 4 i City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 2954900425 6840 FORT DENT WAY 200 Project Name: LINDAL CEDAR HOMES Permit Number: Issue Date: Permit Expires On: M18-0139 11/8/2018 5/13/2019 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: JOHN C RADOVICH DEV CO 2835 82ND AV SE #S-1, MERCER ISLAND, WA, 98040 JOHN MERRILL Phone: (253) 831-4446 MECHANICAL & CONTROL SRVCS INC Phone: (253) 926-9777 (GENERAL) 6426 18TH ST E , FIFE, WA, 98424 MECHACS962BT Expiration Date: 2/26/2020 6426 18TH ST E , FIFE, WA, 98406 DESCRIPTION OF WORK: INSTALL (2) NEW VAV BOXES AND ASSOCIATED EQUIPMENT. MODIFY EXISTING SENSOR, DIFFUSER AND DUCT LAYOUT TO ACCOMMODATE NEW FLOOR LAYOUT. REVISION #1: REMOVE (1) VAV BOX FROM THE SCOPE OF WORK FOR THIS TENANT SPACE AND APPLY IT TO A NEW PERMIT FOR THE TENANT SPACE ADJOINING. Valuation of Work: $30,000.00 Type of Work: Fuel type: ELECT Fees Collected: $615.18 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Permit Center Authorized Signature: Date: 116)--e'-'i I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and .`i.ree to the conditions attached to this permit. Signature: Print Name: Date: ii/25e/i5 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 4: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-A31-3670). 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 8: ***MECHANICAL PERMIT CONDITIONS*** 9: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 10: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0701 ROUGH -IN MECHANICAL 0701 ROUGH -IN MECHANICAL 0701 ROUGH -IN MECHANICAL Parcel No: Address: City of Tukwila 7 1 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 2954900425 Permit Number: 6840 FORT DENT WAY 200 Project Name: LINDAL CEDAR HOMES Issue Date: Permit Expires On: M18-0139 11/8/2018 5/7/2019 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: JOHN C RADOVICH DEV CO 2835 82ND AV SE #S-1, MERCER ISLAND, WA, 98040 JOHN MERRILL Phone: (253) 831-4446 MECHANICAL & CONTROL SRVCS INC Phone: (253) 926-9777 (GENERAL) 6426 18TH ST E , FIFE, WA, 98424 MECHACS962BT Expiration Date: 2/26/2020 6426 18TH ST E , FIFE, WA, 98406 DESCRIPTION OF WORK: INSTALL (2) NEW VAV BOXES AND ASSOCIATED EQUIPMENT. MODIFY EXISTING SENOR, DIFFUSER AND DUCT LAYOUT TO ACCOMMODATE NEW FLOOR LAYOUT. Valuation of Work: $30,000.00 Type of Work: Fuel type: ELECT Fees Collected: $615.18 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Date: h—? -10 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: Date: I This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 4: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not oe valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 8: ***MECHANICAL PERMIT CONDITIONS*** 9: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 10: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0701 ROUGH -IN MECHANICAL z CITY OF TUKW? i Community DevelopmentDepartment Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, 14A 98188 http://www.TukwilaWA.gov Mechanical Permit No. Yt.i g'" 0(3? Project No. Date Application Accepted: 10-? 3 -( S Date Application Expires: `' — a- r 7 (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION King Co Assessor's Tax No.: 295490-0425 Site Address: 6840 Fort Dent Way Suite Number: 220 Floor: 2 Lindal Cedar Homes Tenant Name: PROPERTY OWNER Name: John Merrill Name: John C. Radovich Dev. Co. Address: 6426 18th St. E Address: 2835 82nd Ave. SE City: Fife State: WA City: Mercer Island State: WA Zip: 98040 CONTACT PERSON — person receiving all project communication Name: John Merrill Address: 6426 18th St. E Address: 6426 18th St. E City: Fife State: WA City: Fife State: WA Zip: 98406 Phone: (253) 831-4446 Fax: (253) 926-9222 Email: johnm@groupmcs.com New Tenant: VI Yes ❑..No MECHANICAL CONTRACTOR INFORMATION Company Name: Mechanical & Control Services Address: 6426 18th St. E City: Fife State: WA Zip: 98406 Phone: (253) 296-9777 Fax: (253) 926-9222 Contr Reg No.: MECHACS962BT Exp Date: 01/30/2018 Tukwila Business License No.: 0997334 Valuation of project (contractor's bid price): $ 30,000 Describe the scope of work in detail: Install (2) new VAV boxes & associated equipment. Modify existing senor, diffuser & duct layout to accommodate new floor layout. Use: Residential: New ❑ Replacement ❑ Commercial: New 121 Replacement ❑ Fuel Type: Electric 121 Gas Other: H:\Applications\Forms-Applications On Line\2016 Applications\Mechanical Permit Application Revised 1-4-16.docx Revised: January 2016 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Residential, Nighttime Furnace >100k btu 2 Floor furnace 9 Suspended/wall/floor mounted heater 57 dB(A) Appliance vent I. Repair or addition to heat/refrig/cooling system 47 dB(A) Air handling unit 65 dB(A) <10,000 cfin 60 dB(A) Unit Type Qty Air handling unit Residential, Nighttime >10,000 cfm 2 Evaporator cooler 9 Ventilation fan 57 dB(A) connected to single duct I. Ventilation system 47 dB(A) Hood and duct 65 dB(A) Incinerator — domestic 60 dB(A) Incinerator — comm/industrial 65 dB(A) Unit Type Qty Fire damper Residential, Nighttime Diffuser 15 Thermostat 9 Wood/gas stove 57 dB(A) Emergency generator Commercial Other mechanical equipment 47 dB(A) 60 dB(A) 65 dB(A) Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-10PM, Monday through Friday and 8AM-10PM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: • Warning devices; • Construction and property maintenance during the daytime hours (7am-lOpm); • Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AU O ' .' ED AGENT: Signature: Date: Print Name: John Merrill Day Telephone: (253) 831-4446 Mailing Address: 6426 18th St. E H:Wpplications\Forms-Applications On Line \2016 Applications\Mechanical Permit Application Revised 1-4-16.docx Revised: January 2016 bh 3// Fife WA 98406 City State Zip Page 2 of 2 / \ DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY - PAID $496.87 M18-0139 Address: 6840 FORT DENT WAY 200 Apn: 2954900425 $496.87 Credit Card Fee $14.47 Credit Card Fee 8000.369.908.00.00 0.00 $14.47 MECHANICAL $459.43 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $426.28 TECHNOLOGY FEE $22.97 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R15797 R000.322.900.04.00 0.00 $22.97 $496.87 Date Paid: Thursday, November 08, 2018 Paid By: JOHN PARKS Pay Method: CREDIT CARD 518070 Printed: Thursday, November 08, 2018 1:07 PM 1 of 1 SYSTEMS Page 1 of 2 CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA 0017340000802374464500 Date: 11/08/2018 01:07:17 PM CREDIT CARD SALE VISA CARD NUMBER: **********2615 K TRAN AMOUNT: $496.87 APPROVAL CD: 518070 RECORD #: 000 CLERK ID: jazzel X {CARDHOLDER'S SIGNATURE} I AGREE TO PAY THE ABOVE TOTAL AMOUNT ACCORDING TO THE CARD ISSUER AGREEMENT (MERCHANT AGREEMENT IF CREDIT VOUCHER) Thank you! Merchant Copy https://classic.convergepay.com/VirtualMerchant/transaction.do?dispatchMethod=printTr... 11/08/2018 Page 2 of 2 CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA Date: 11/08/2018 01:07:17 PM CREDIT CARD SALE VISA CARD NUMBER: **********2615 K TRAN AMOUNT: $496.87 APPROVAL CD: 518070 RECORD if: 000 CLERK ID: jazzel Thank you! Customer Copy https://classic . convergepay.com/VirtualMerchant/transacti on. do ?di spatchMethod=printTr... 11 /08/2018 DESCRIPTIONS PermitTRAK ACCOUNTQUANTITY PAID $118.31 M18-0139 Address: 6840 FORT DENT WAY 200 Apn: 2954900425 $118.31 Credit Card Fee $3.45 Credit Card Fee R000.369.908.00.00 0.00 $3.45 MECHANICAL $114.86 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R15694 R000.322.102.00.00 0.00 $114.86 $118.31 Date Paid: Tuesday, October 23, 2018 Paid By: KOHN PARKS Pay Method: CREDIT CARD 513264 Printed: Tuesday, October 23, 2018 1:46 PM 1 of 1 SYSTEMS r, CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA Date: 10/23/2018 01:46:12 PM CREDIT CARD SALE VISA CARD NUMBER: **********2615 K TRAN AMOUNT: $118.31 APPROVAL CD: 513264 RECORD #: 000 CLERK ID: Bill Thank you! Customer Copy Page 2 of 2 https://classic.convergepay. com/VirtualMerchant/transaction.do?dispatchMethod=printTr... 10/23/2018 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMI NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: e I �i Nd ow %k�nt.S Tyf In ectior�;� [Q I ®1 �n t car,( f / rV C. Address: 66140 Art ll�l Date Called: Special instructions: Com, 1 _ 14_ zo-D _ Date Wanted: 2 , `� � � ^ _ 00/Er Reques e Phone No: 70(z7,-&gJ2 pproved per applicable codes. LJ Corrections required prior to approval. CO MENTS: Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD q Retain a copy with permit M« 013 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 ProIect: & L►� a of Inspection: I O ihifiL Address: 68110 fe;f \/4c--- Date led: Special Instructions: a-400Date Wanted: a.m. Requester: Phone No: ['Approved per applicable codes. D Corrections required prior to approval. COMMENTS: Ok- NCA/ NI%RrH s7 D, V u,ottidL/ Inspector: Date: /1-15 ^ rr8 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. price® r Job Name: Customer: Date Printed: Spec Section: Contact: LINDAL MCS 10/22/2018 15 - HVAC Terminals Submittals 6100 SIXTH AVENUE S SEATTLE, WA 98108 REVIEWED FOR CODE COMPLIANCE APPROVED OCT 2 6 2010 City of Tukwila BUILDING DIVISION MSN- ou., RECEIVED CITY OF TUKWILA OCT 2 3 2018 PERMIT CENTER VMPPS\Price\lobs\LianneS\UNDAL.aio-projx 8 c O CJOV9) 01 ?W IN..) -.a cnZDD.�O6 O(J) WZOmCn-, , '< Q o-0 0v� 5' CD 3 CSD Q (nD v CSD (v:iN.`§s�cn�Scn � 3 -, tD = oo Cnn Cn O O c0i O C 9.2 CD <' '- -0 O CD Q v �. .(D < cD D 3 (D tb NCD 3O O N Cn Q Q 3 O n CD cDa N (n O n C CD *S a" < CO. -p C2 (n O Z 3 Q 3 N CD N 0 (D 0 Cn --,,O p 0 0(0 ?Q< m-1 o O r" Ti -� * n. CD CDCT c r n 3 5. -C3 O CD cn • Q = - (O!) (D n C cn o (D Q-c-p-•Cp < —C7 CD Cn CD O- O ? co O C2 (Dc (D 3.3�=h• �Da0oa) CD -, C2 O O -0 CD n CD ._+ O Cn (D C C-* C CD S< n O -O O. _0_ a-0 CD _3 n CD CSD OO O (D O CD CD Fir O n D 0 CD N n Q (-s O C (� Cr a CD rn D C. • O o w, ' 3 D o :-' S CD Q CD < CD 3W 3 O O n CD3. — CO= O =~ pp 0) O ami CD = O 0 9 N O to o CS 7- -0 O Cfl N o. m O 0 CF:) CD N O CZ Cn 0) = IAC- = N DD o _. m _ CO g mal T p X a)(v .Q ) SD m c m U) = o R' o v m 0 sy �� m v CA : v) O a) a N O CD '� co (D O co V' -'ii3 a) N IV IV ? O < O CD CD CD 9) � u)-- 3 Cr CO _ (p CD (1)7J <' ^*' O D D CD CD Q -O m 33 < 0 67") o sl)(D C. Q0 c 0)C C m 0° m a O -h �� 0) �O 0) m o� m IV v (D O C `< o CO CO cD 5. 0 CO C 3 0 0 �* 0 D (.0 -0 I . _' m 5 sa;oN a3ueuuoped 8L0Z/ZZ/01. :paluiad a}ep price& Submittal Sheet FUVS 1 -an cowered, VAV - UUU by Utners FDV5 Fan Powered Variable Volume, Digital Controls by Others BACKDRAFT DAMPER STRAIGHT FLANGE L DI- SCHARGE B ASR L 1 - — 1"(25) RETURN AIR w ®PRIMARY AIR 9i"(241)—SZ.6-12 11 ,"(292)—SZ.14-16 Dimensions - IMPERIAL UN TS (inches) Unit Size Maximum Fan CFM Primary Air Inlet Return Air Inlet Outlet Duct w H L Gauge g 0 EBC 3.5 3 3010 1350 10 12 15% 14 12%2 3117%225Y2 22 ECM Motor Unit Motor Full Load Amps Size H.P. 115V 240V 277\# 3010 1/2 7 3.5 3 Controls r- i"(19) MOTOR CONTROLS I) ENCLOSURE L MULT1—POINT SENSOR BLOWER ACCESS PANEL NEMA 1 CONTROLS ENCLOSURE • Pressure independent • Controls are supplied by controls contractor and field installed • Controls mounted on left hand side of unit • PS - Controls enclosure included • 277-24V Control Transformer supplied, factory mounted • Multi -point primary airflow sensor supplied by Price Notes • 22 Ga. zinc coated steel casing. Mechanically sealed and gasketed, leak resistant construction • Primary damper blade constructed of two layers of heavy gauge galvanized steel with a sandwiched peripheral gasket • 1/2" (13) dia. plated solid steel slhaft with end indicator mark showing damper position • Damper leakage rated below 2% of nominal flow at 3" w.g. (747Pa). Damper closing direction - CCw • Units not to be used for temporary heat or ventilation during construction • Minimum 0.1" w.g. (25 Pa) extemal static pressure to operate • Refer to submitted box schedule for air volumes and inlet sizes • Rectangular discharge opening with slip connection aus Intertek Assembly UL1995 & CSA236 listed Motor • ECM electric motor 1 phase, 60 cycle. Speed controller included • MFUS - Motor Fusing PROJECT: LINDAL SUBMITTAL NO: 258514-A SUBMITTAL DATE: 10/22/2018 ENGINEER: CUSTOMER: MCS DESCRIPTION: Fan Powered, VAV - DDC By Others FDV5//I/8000/3010/FLD/CFM/277-ECM/925/277-24V//0.0/////////FF/H B/PS/MFUS//////////////////// Copyright Price Industries 2018 All metric dimensions () are soft converted. Imperial dimensions are converted to metric and rounded to the nearest millimeter. larketing Release version: 2.18.10.1, All In One version: 3.18.10 Information within this document is subject to change without notice. price° Submittal Sheet FDV5 Fan Powered, VAV - DDC By Others Liner FF 3/4" Fiber Free Foam Insulation HOUSING FOAM INSULATION HOUSING Internal Insulation - Fiber Free Foam 3/4" (19mm) thick, min. 1.5 Ib/cu.ft density, meets requirements of NFPA90A and UL 181. R -value = 3 Hanger Brackets HB SHIPPED LOOSE Suggested HB Locations Image is for reference only. It may not reflect the exact arrangement of accessories. • Hanger brackets are 12 Ga. zinc coated steel • Brackets are shipped loose for field installation for use with threaded hanger rods (by others) • Layout indicates suggested hanger bracket locations PROJECT: LINDAL SUBMITTAL NO: 258514-A SUBMITTAL DATE: 10/22/2018 ENGINEER: CUSTOMER: MCS DESCRIPTION: Fan Powered, VAV - DDC By Others FDV5//I/8000/3010/FLD/CFM/277-ECM/925/277-24V//0.0/////////F F/H B/PS/MFUS//////////////////// Copyright Price Industries 2018 All metric dimensions () are soft converted. Imperial dimensions are converted to metric and rounded to the nearest millimeter. larketing Release version: 2.18.10.1, All In One version: 3.18.10 Information within this document is subject to change without notice. prow Submittal Sheet ruVS ran rowerea, VAV - UUU by Utners FDV5 Fan Powered Variable Volume, Digital Controls by Others 10$"(270)— BACKDRAFT DAMPER ®DISCHARGE AIR SLIP & DRIVE CONNECTION r 18"(457) MAXIMUM DOOR WING 1 t 1 1 L RETURN AIR PRIMARY AIR 6"(152) HINGED DOOR t9i"(241)—SZ.6-12 TRIC COIL 112"(292)—SZ.14-16 ENCLOSURE 1"(25) Dimensions - IMPERIAL UNITS (inches) Unit Maximum Fan Primary Air Return Air Inlet Outlet Duct W H L K Gauge D E BC Size CFM Inlet 2006 750 6 12 15 )4 14 12 )6 31 17 'A 36 1A 16 )6 22 ECM Motor Unit Motor Full Load Amps Size H.P. 115V 240V 277\, 2006 1/3 3.9 1.9 1.6 Controls MOTOR & HEATER CONTROLS BLOWER ACCESS PANEL NEMA 1 CONTROLS ENCLOSURE MULl1—POINT SENSOR "(3) 6"(152) 1"(25) E H 4i"(121) • Pressure independent • Controls are factory mounted, supplied by controls contractor • Controls mounted on left hand side of unit • PS - Controls enclosure included • 277-24V Control Transformer supplied, factory mounted • Multi -point primary airflow sensor supplied by Price Notes • 22 Ga. zinc coated steel casing. Mechanically sealed and gasketed, leak resistant construction • Primary damper blade constructed of two layers of heavy gauge galvanized steel with a sandwiched peripheral gasket • 1/2" (13) dia. plated solid steel shaft with end indicator mark showing damper position • Damper leakage rated below 2% of nominal flow at 3" w.g. (747Pa). Damper closing direction - CCw • Units not to be used for temporary heat or ventilation during construction • Minimum 0.2" w.g. (50 Pa) external static pressure to operate • Refer to submitted box schedule for air volumes and inlet sizes Intertek Assembly UL1995 & CSA236 listed Motor • ECM electric motor 1 phase, 60 cycle. Speed controller included • MFUS - Motor Fusing PROJECT: LINDAL SUBMITTAL NO: 258514-A ENGINEER: CUSTOMER: MCS DESCRIPTION: Fan Powered, VAV - DDC By Others FDV5//I/8003/2006/FAC/CFM/277-ECM/315/277-24V/EC/2.5/277-1 /SCRV/AFS/FUS/I DSW////FF/H B/PS/MFUS////////////////////SCR-111 SUBMITTAL DATE: 10/22/2018 Copyright Price Industries 2018 All metric dimensions () are soft converted. Imperial dimensions are converted to metric and rounded to the nearest millimeter. larketing Release version: 2.18.10.1, All In One version: 3.18.10 Information within this document is subject to change without notice. rice Submittal Sheet FDV5 Fan Powered, VAV - DDC By Others Liner FF 3/4" Fiber Free Foam Insulation HOUSING FOAM INSULATION HOUSING Internal Insulation - Fiber Free Foam 3/4" (19mm) thick, min. 1.5 Ib/cu.ft density, meets requirements of NFPA90A and UL 181. R -value = 3 Electric Coil r [7/8°(22) B 3/4"(19) L ry1{11111111111111111111/,c 11111111++ -Y59 11 111 H11 IH11111 Unit Size IMPERIAL UNITS (inches) Outlet Duct M BxC 2006 14 x 12 % 15 Standard Coil Notes • Automatic reset thermal cutout • Manual reset thermal cutout • Refer to submitted control diagrams for standard control components to be supplied • Hinged access door • Minimum 0.2" w.g. (50 Pa) external static pressure to operate • Slip and drive discharge connection • Heater section not insulated Electrical Configuration Supply Voltage: • 277/10 (2 Wire) Stages/Control: SCRV • SCR voltage control with 0-10 VDC control signal • SCR -111 (1 Phase SCR, 10 Amps Max / 480 Volts Max) • 20 Ga. galvanized steel construction • Fan interlocked with heating elements • Low watt density elements, high grade nickel -chrome alloy • 70 CFM per kW minimum air flow across heater coils • Assembly ETL certified to UL1995 & CSA236 • Single point electrical connection • Magnetic contactors where required Selected Coil Features • AFS - Air flow switch • FUS - Main supply fuses • IDSW - Door Interlock Disconnect Switch PROJECT: LINDAL SUBMITTAL NO: 258514-A ENGINEER: CUSTOMER: MCS DESCRIPTION: Fan Powered, VAV - DDC By Others FDV5//I/8003/2006/FAC/CFM/277-ECM/315/277-24V/EC/2.5/277-1 /SCRV/AFS/FUS/IDSW////FF/HB/PS/MFUS////////////////////SCR-111 SUBMITTAL DATE: 10/22/2018 1 Copyright Price Industries 2018 All metric dimensions () are soft converted. Imperial dimensions are converted to metric and rounded to the nearest millimeter. larketing Release version: 2.18.10.1, All In One version: 3.18.10 Information within this document is subject to change without notice. priest Submittal Sheet FUVS fan I- owerea, VAV - UL)U by utners Hanger Brackets HB SHIPPED LOOSE Suggested HB Locations Image is for reference only. It may not reflect the exact arrangement of accessories. • Hanger brackets are 12 Ga. zinc coated steel • Brackets are shipped loose for field installation for use with threaded hanger rods (by others) • Layout indicates suggested hanger bracket locations ELECTRIC HEAT PROJECT: LINDAL SUBMITTAL NO: 258514-A SUBMITTAL DATE: 10/22/2018 ENGINEER: CUSTOMER: MCS DESCRIPTION: Fan Powered, VAV - DDC By Others FDV5//I/8003/2006/FAC/CFM/277-ECM/3151277-24V/EC/2.5/2T7-1 /SCRV/AFS/FUS/I DSW////FF/H B/PS/MFUS////////////////////SCR-111 Copyright Price Industries 2018 All metric dimensions () are soft converted. Imperial dimensions are converted to metric and rounded to the nearest millimeter. tarketing Release version: 2.18.10.1, All In One version: 3.18.10 Information wihin this document is subject to change without notice. / " PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M18-0139 DATE: 10/23/18 PROJECT NAME: LINDAL CEDAR HOMES SITE ADDRESS: 6840 FORT DENT WAY X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: Building Division Public Works Fire Prevention Structural Planning Division nPermit Coordinator P1 PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 10/25/18 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 11/22/18 Approved n Approved with Conditions7.1 Corrections Required n Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg D Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 City of Tukwila REVISION SUBMITTAL Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: I I a g II Plan Check/Permit Number: / t) 0) 3 ❑ Response to Incomplete Letter # 111 Response to Correction Letter # Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner ❑ Deferred Submittal # Project Name: L.71,11 SPA. Yar Ce ! Project Address: 6$4 0 For+. UK+ lJ Ay / s�e 2 ?jO Contact Person: 1'4i1N MMere? I' / Phone Number: a 5 3' 3 3/.1t -ii -y6- Summary of Revision: e� /RehalOV?n (i_) VII `l box Scr0ivt e_)t5+°�► � erns Vii- �� RECEIVED CITY OF TU MIL/ NOV 2 8 2018 Sheet Number(s): "Cloud" or highlight all areas of revision including dat evision Received at the City of Tukwila Permit Center by: Entered in TRAKiT on [ W:\Permn Center \Templates\Forms \Revision Submittal Formdoc Revised August 2015 MECHANICAL & CONTROL SP °S INC - Home Espanol Costa et Safety & Health Claims & Insurance Washington State Department of 46. ) Labor & Industries [Search LW Page 1 of 3 A. --Z Index Help 61y Workplace Rights Trades & Licensing MECHANICAL & CONTROL SRVCS INC Owner or tradesperson Principals Hull, Travis Edward, PRESIDENT Hunt, Ted Lamond, VICE PRESIDENT HULL, ANGELA DAWN, SECRETARY GROVER, HAROLD, VICE PRESIDENT (End: 02/26/2010) DICKSON, PAUL, TREASURER (End: 02/26/2010) Doing business as MECHANICAL & CONTROL SRVCS INC WA UBI No. 602 338 440 6426 18th St E FIFE, WA 98424 253-926-9777 PIERCE County Business type Corporation Governing persons ANGELA DAWN HULL TRAVIS EDWARD HULL; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. MECHACS962BT Effective — expiration 01/30/2004— 02/26/2020 Bond American Contractors Indem CO Bond account no. 100239439 $12,000.00 Received by L&I Effective date 02/10/2014 02/06/2014 Expiration date Until Canceled Bond history Insurance Continental Insurance Co Policy no. 6023856626 $1,000,000.00 Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602338440&LIC=MECHACS962BT&SAW= 11/08/2018