Loading...
HomeMy WebLinkAboutPermit M18-0146 - MOUNTAIN VIEW APARTMENTS - ENERGY RECOVERY VENTS AND KITCHEN HOOD VENTSMOUNTAIN VIEW APTS 14210 37 AVE S COMPLEX M18-0146 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 1610000225 14210 37TH AVE S COMPLEX Project Name: MOUNTAIN VIEW APARTMENTS Permit Number: M18-0146 Issue Date: 11/27/2018 Permit Expires On: 5/26/2019 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: MOUNTAIN VIEW FAMILY ASSOC P 0 BOX 2170 QUANTUM MANAGEMENT SVCS INC, LYNNWOOD, WA, 98036 GRACE GARLAND 10612 NE 46 ST, KIRKLAND, WA, 98033 UCONS LLC 10612 NE 46 ST, KIRKLAND, WA, 98033 UCONSL*962RZ Phone: (425) 576-8728 Phone: (425) 576-8728 Expiration Date: 3/1/2019 DESCRIPTION OF WORK: INSTALL ENERGY RECOVERY VENT IN EACH APARTMENT. REPLACE KITCHEN RANGE HOOD VENT. Valuation of Work: $65,000.00 Type of Work: REPLACEMENT Fuel type: ELECT Fees Collected: $1,089.51 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: 125 Sewer District: VALLEY VIEW Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Date: 1 )- -7"fL I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulati onstruction or the performance of work. I am authorized to sign and obtain this development permit a a: ee to the conditions attached to this permit. Signature: / Print Name: J r /1 C C g- Date: 1) / This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 4: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 5: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be obtained at City Hall in the office of the City Clerk. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: ***MECHANICAL PERMIT CONDITIONS*** 10: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 11: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1800 MECHANICAL FINAL 0701 ROUGH -IN MECHANICAL 1 CITY OF ALAI Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TulcwilaWA.gov Mechanical Permit No. i 6-01110 Project No. Date Application Accepted: 1 1-9-1 0 (For office use only) Date Application Expires: MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address: i/ °/ 0 3 7it /1-c' Z 5 King Co Assessor's Tax No.: /40k106 _ 49;;2,77 Suite Number: Floor: New Tenant: ❑ Yes „No Tenant Name: M pt,.n41,2, 1.1 1/ ii LtJ /4 pccri t1 o f j PROPERTY OWNER Name: �Cur' l Name: Pt O 1I i^ 9.01 to e c'Q lvu !ate >56?"� Address: izi.-_,,Lig l �y ! 4.ve, 6 „} State:1 t j City: ---{�bC GtltJ.'.� i- l c.i State: j Zap. ` ed CONTACT PERSON — person receiving all project communication Name: �Cur' 27cfOa City: A-;44,. >d State: �A- Zip:, Address: 1 0 C;? 1 P- L( ( Tukwila Business License No.: City: n1 Q tc( , State:1 t j Zip, Phone: _ 5-76 Fax: Email: !! r l I, u c o..?.(%)Yv^: MECHANICAL CONTRACTOR INFORMATION Company Name: l itioP Address: jaze/- 46sz. City: A-;44,. >d State: �A- Zip:, Phone:gjs_%lam _87 8„, Fax: ' $9_7 r,,w9 Contr Reg No.:u(i.eb 2_ g6 ,, ,,Exp Date:. ,1lI � . Tukwila Business License No.: Valuation of project (contractor's bid price): $ f pn6 Describe the scope of work in detail: 1- OSLO epig rey.j retawerY vef 1-r\ Pa.e Q pat -41"Q Alt Ottee-- > +..-1-IHR►ti hoed ve Use: Residential: New 0 Replacement Commercial: New 0 Replacement 0 Fuel Type: Electric tk Gas ❑ Other: IJAApplications\Forms-Applications On Linc12016 Applicationns\Mechanial Permit Application Revised 1-4-16.docx Revised: January 2016 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type [Qty Furnace <100k btu Residential, Nighttime Furnace >100k btu Industrial Floor furnace 55 dB(A) Suspended/wall/floor mounted heater 57 dB(A) Appliance vent Commercial Repair or addition to heat/refrig/cooling system C i Air handling unit � 1 <10,000 cfm 60 dB(A) Unit Type Qty I Air handling unit Residential, Nighttime >10,000 cfm Industrial Evaporator cooler 55 dB(A) Ventilation fan connected to single duct 57 dB(A) Ventilation system Commercial Hood and duct C i Incinerator — domestic � 1 Incinerator — comm/industrial 60 dB(A) Unit Type I Qty I Fire damper Residential, Nighttime Diffuser Industrial Thermostat 55 dB(A) Wood/gas stove 57 dB(A) Emergency generator Commercial Other mechanical equipment 47 dB(A) . (4Y � 1 1 Boiler/Compressor 0-3 hp/100,000 btu Qty 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-10PM, Monday through Friday and 8AM-10PM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: • Warning devices; • Construction and property maintenance during the daytime hours (7am-lOpm); • Testing of backup generators during the day. PERMIT APPLICATION NOTES - 1 Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR A ' t RI 1 D ENT: Signature: (�✓lrc - Print Name: f J Mailing Addre : %art r;L.,4 It (00 N)r 4it*" - Date: 1 (,2' fit. (�A Day Telephone: yp-- H:\ApplicationsWorns-Applications On Line12016 ApplicatimalMechanical Permit Application Revised 1.4-16.docx Revised January 2016 bb r lel x,114 1,J 1 18•65-5 City State Zip Page 2 of 2 f 1 PermitTRAK DESCRIPTIONS ACCOUNT QUANTITY $1,089.51 M18-0146 Address: 14210 37TH AVE S COMPLEX Apn: 1610000225 $1,089.51 Credit Card Fee Credit Card Fee $31.73 R000.369.908.00.00 0.00 $31.73 MECHANICAL $1,017.10 PERMIT ISSUANCE BASE FEE PERMIT FEE PLAN CHECK FEE R000.322.100.00.00 R000.322.100.00.00 R000.322.102.00.00 0.00 0.00 0.00 $33.15 $780.53 $203.42 TECHNOLOGY FEE $40.68 TECHNOLOGY FEE TOTAL FEES PAID, BY RECEIPT: R15801 R000.322.900.04.00 0.00 $40.68 $1,089.51 Date Paid: Friday, November 09, 2018 Paid By: JOSEPH WOLERY Pay Method: CREDIT CARD 03334G Printed: Friday, November 09, 2018 8:48 AM 1 of 1 SYSTEMS Page 2 of 2 CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA Date: 11/09/2018 08:47:39 AM CREDIT CARD SALE VISA CARD NUMBER: **********6480 K TRAN AMOUNT: $1,089.51 APPROVAL CD: 03334G RECORD #: 000 CLERK ID: Bill Thank you! Customer Copy https://classic.convergepay. com/V irtualMerchant/transaction.do?dispatchMethod=printTra... 11/9/2018 INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: / iiiiro 1 Type of IIAnslpeection: A �d[rr1 e�ss: /J C_.0 G 1 n' 4' - Date Called: Special Instructions: Wanted: Date Wanted: Requester: bJ 6 J Phone No: 3(0® 411 LO 0 Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: it/Iue- vi Cts - -F,A)A- .-- - ,,Nl Co-t...4.4.RJ f1a,.W •92oz vikATJ448„,,_ REINSPECTION FEE R QUIRE!). Prior to next inspection, fee must be Inspector: Date: -4- t, paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSP ON NO. PERMT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: ( �0i4—( Type of Inspection: ` _` -" - 1/tkl�-v64-0•Jt t__ Address: 242c ttb ' Date Called: 133 Special Instructions: Date Wanted: 2•.2 a) p.m. Requester: �� �h((,�t:10 Phone No: 761&) Ile S-932._ Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: Date: REINSPECTION FEE EQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. POO INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: IrioAriirot',Nan.) 1-r'vl`, T pe of Inspection: m kAA1 Address:Date Pizl a 37 eS i t� Called: Special Instruc io s: �C�,u -r-o-Re Me1 onS ii.... Date Wanted: nester; WI'D�!`� Phone No: ZS3- 205 -,ss 3 (c ❑ Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: Date: /4-16 REINSPECTION FgE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Inspector: iO3r011d M3IA NId1NfON1 REVIEWED FOR eDE COMPLIANCE APPROVED t 5. : MUM,* VIIM MARROWS TNMA11BtFt INASOM LINING 1 t �e OMPilat » nn1 .T "C NOIAlIG NOV 2 0 2018 fv) 12g - City of Tukwila BUILDING DIVISION KOVALENKO HALE ARCHITECTS awe W Y�=• EIVED CITY OF TUKWILA NOV 0 9 2018 'Er,iyli f' CENTER ai 0 C N 0 .0 F C CJ cn cl 4C2 0 co .0 0 () r: riC) • CJ cJuP- o .5 cc s- o c eL• < •0 co co > 0 o. as 0 C/3 5 - 0 ``c) z co t:13.LN?.0 111".18Go 910Z 6 U AON A113 a /42031:1 s 111131111 alvx. ONN31VAON KOMINOISININSWV94.311311 POIDNNOVItt If KOMI trAtletThugkItta3; snsvmJr,sa. MY. ominow WAR OVICUNIVACWASOCI 1111,itUAirN NEM WAJOICII pnumnxurnalk v1 -y 11.1,11,11.1.11.1.4 ,4 Wt.?" I ZMHS Energy Recovery Veni t RECEIVED CITY OF TUKWILA NOV 0 9 2018 PERI'j T CENTER CEIVED F TUKWILA V 0 9 2018 IT CENTER 14218 37th Avenue South,... X Y S 142nd St S 142nd St ade View mmqunit 14218 37th Ave S Tukwilaq WA 98165 a 1 hr 11 min Share Q Save • 1 0 L ECEIVED OF TUKWILA OV 0 9 2018 MIT CENTER At. ‘- kvi TwinFresh Expert RA1-50 PRODUCT TECHNICAL SPECIFICATIONS DATA r-- .-,7 1---) RA1-50-2 .. SINGLE ROOM ERV UNITS DESCRIPTION *3a am TwinFresh Expert is the Single Room Ventilation Solution. One TwinFresh unit can serve rooms up to 343 SQFT. Recovers heat and moisture to reduce heating costs in winter and air con- ditioning costs in summer. Wishper quiet operation, as low as 0.3 SONES. DESIGN Aluminium or stainless steel outer hood: Modern design that fits any interior and exterior / 100% corrosion proof. DIMENSIONS RA1-50 Vii;-' `'' g, -,' PERFORMANCE j,.......................................—Speed , 9= -- ' �," RA1-50-2 , - Plug -&-Play installation: No special skills required / No balancing needed / Through the wall installation. Compact unit design. Multifunctional Wireless Remote Control. Almost no maintenance required: Washable filter and core. MERV6 air purification. Antibacterial treatment of ERV core and filters. Automatic shutters. MOTOR EC -motor with eficacy 5.6 CFM/W (Twice as high as the Energy Star requirement) TwinFresh Expert 1 2 3 REVIEWED FOR CODE COMPLIANCE APPROVED NOV 2 0 2018 City of Tukwila BUILDING DIVISION Supply voltage, 50/60 Hz [V] 1-100-230 Power [W] 3.61 4.15 5.2 Max. current consumption [A] 0.025 0.030 0.039 Max. air capacity [CFM] 9 18 29 RPM [min-'] 800 1300 1900 Sound pressure level [Sones] 0.3 0.5 0.6 Max. transported air temperature F] from -22 up to + 122 Recovery Efficiency 97 90 82 RFC P!VED MODEL QUANTITY COMMENTS PROJECT CITY OF TLJKV! location: architect: NOV 0 9 ZUE engineer: PERMIT Cm contractor: submitted by: Tel: 888-640-0925 Sales@ventsus.com '• 513-348-3853 VentsUS.com -- COMOZ, Fax: 513-268-4597 11013 Kenwood Road, Cincinnati, Ohio 45242 cC(E 1 � use" ' �` V, `^ A1C% ME MEMBER' MEMBER PERMIT CENTER Updated 8-18 SPECIFICATIONS • • Ventilation Products R, ECQ RANGE HOODS 2100 ■, 250 CFM/4.0 Sones (Vertical) @ 0.10" S.P. H VI 150 CFM/0.6 Sones (Vertical) @ 0.03" S.P. CERTIFIED 250 CFM/3.5 Sones (Horizontal) @ 0.10" SP. 150 CFM/0.6 Sones (Horizontal) @ 0.03" SP. Continuous Performance @ 0.03" SP. 30 CFM/<0.3 Sones,50 CFM/<0.3 Sones 70 CFM/<0.3 Sone90 CFM/<0.3 Sones • Dimensions GEM Overall bottom projection: 191/2" ® Height: 7'/2" Widths: 24", 30", 36" • Hood Body Stainless Steel: 24 gauge, grade 430 stainless steel. Painted: 23 gauge cold rolled commercial rode CRCQ steel,auto ..._._.. welded, coated with a baked enamel finish. • Adjustable Capacity Motor,-----_____ 21/4" x 10" knock-out for 4 capacity settings on low speed allow the fan to be set to the required 12' exhaust rate for continuous ventilation. Low speed set points include: 30 50 70 or 90 CFM High speed rapidly clears the air of moisture, odors or other contaminants. 71/.. Ideal for compliance with Ashrae 62.2, LEED, ENERGY STAR® for Homes, California Title 24 and other programs. Suitable for continuous operation, thermally protected, permanently lubricated, 120V 60 Hz. with two electronically balanced blower wheels. Internal On/Off switch allows override of continuous ventilation operation. • Lighting 11 ,✓ 9 �2 _ 7 �. 8 . 1 ,j8 , G 9%" 24", 30", 27 /a 11/2" ✓o 1 2" 36" Xdx 10" uct connection duc rectangular 7 /2" Includes 8W GU24 base LED lamp (included) • Ducting Options Horizontal, Vertical ducting: 31/a"x 10" (duct adapter and damper included). • Mounting Wall mounted. Install 20" to 30" from cooking surface. m T TLE Cof.'PLIES 4iTH ASHRAE 0 4 1 • Filters 62.ZQ;•� Grease Filter (included): GF-01 (30", 36" models), GF-07 (24" models). yISALASSOMIPS • Available Finishes vEN,>i° Stainless Steel (ECO248, EC0308, White (ECO243, EC0303, EC0363), Air Flow - CFM EC0368), Black (ECO246, EC0306, EC0366) EXPANDED PERFORMANCE Static Pressure (inches of w.g.) 0 0.1 0.125 0.15 0.2 0.25 Sones GP .1 SP Fan Speed RPM Maximum Fan Watts Amps High Speed (horizontal) 280 250 241 233 213 175 3.5 1623 75.0 0.8 High Speed (vertical) 281 250 242 232 213 175 4.0 1653 75.0 0.8 Working speed of 150 CFM, 0.6 sones @ 0.03 SP., 45.0 Watts (horizontal), 47.0 Watts (vertical • 4 steps of adjustment between 30 and 90 CFM for continuous speeds PROJECT ARCHITECT LOCATION ENGINEER CONTRACTOR SUBMITTED BY DATE FAN NUMBER MODEL NUMBER CFM IN W.C. RPM WATTS AMPS SONES QTY OPTIONAL EQUIPMENT & REMARKS .E.N AMEp�9 RECEIVED y %: `� • ITY OF TU K W I L Air King: 820 Lincoln Avenue Canada: E1� �..::::. c us A �'�-� West Chester, Pennsylvania 19380-4466 Brampton, Ontario ���.�� Tel: (610) 692-7400.877-304-3785 Tel: 905-456-2033 Intertek ENERGY STAR 9'04-S — NOV 0 9 2018 Fax: (610) 696-8048 Fax: (905) 456-1015 PERMIT CENTER Updated 8-18 Whisper Se(eet1M VENTILATION FAN Specification Submittal Data / Panasonic Ventilation Fan Description Customizable Ventilation Fan shall be low sone ceiling mount rated for continuous run. Fan shall be ENERGY STAR® rated and certified by the Home Ventilating Institute (HVI). Evaluated by Underwriters Laboratories and conform to both UL and cUL safety standards. Motor/Blower: • Enclosed DC brushless motor technology rated for continuous run. • Fan ventilation rates shall be manually adjustable for 50-80-110 CFM. • Power rating shall be 120 volts and 60 Hz. • Fan shall be UL listed for tub/shower enclosure when used with a GFCI protected circuit and used in insulated ceiling (TYPE I.C.). • Fan equipped with a thermal cutoff fuse • Removable, permanently lubricated, plug—in motor. Housing: • Rust proof epoxy and polyester resin coating, 26 gauge galvanized steel body. • Integrated dual 4" or 6" diameter duct adapter. • Built-in metal flange provides blocking for penetrations through drywall as an Air Barrier, and assists with the decrease in leakage in the Building Envelope during blower door testing. • Built in backdraft damper. • Articulating and expandable installation bracket up to 24". Grille: • Attractive design using Poly Pro material. • Attaches directly to housing with torsion springs. • Includes a motion sensor cap for use as a cover when motion sensor Plug 'n PIayTM module has not been selected. Warranty: • ALL Parts: 3 Years from original purchase date. DC Motor: 6 Years from original purchase date. Architectural Specifications: Customizable Ventilation Fan shall be ceiling mount, ENERGY STAR® rated type with built-in speed selector. Select from 50/80/110 CFM and no more than <0.3 sone as certified by the Home Ventilating Institute (HVI) at 0.1 w.g. with no less than 53/82/113 CFM and no more than <0.3/0.4/0.8 sones at .25 w.g. Power Consumption shall be no greater than 3.2/5.4/9.8 watts at 0.1 w.g. and 6.5/10.2/16.1 watts at 0.25 w.g. ENERGY STAR® rated with efficiency of no less than 15.1/15.3/11.5 CFM/watt at 0.1 w.g. and than 8.1/8.4/7.2 CFM/watt at 0.25 w.g. The motor shall be enclosed with brushless DC motor engineered to run continuously. DC motor speed shall automatically increase when the fan senses static pressure to maintain selected CFM. Power rating shall be 120v/60Hz. Duct diameter shall be no less than 4", inclusive of an integrated dual 4" or 6" duct adapter. Plug 'N Play"' modules provide up to three additional features. Select from Multi -Speed with Time Delay, Condensation Sensor, LED Night Light and Motion Sensor. Fan shall be UL and cUL listed for tub/shower enclosure when used with a GFCI protected circuit. Fan can be used to comply with ASHRAE 62.2, LEED, ENERGY STAR® IAP, EarthCraft, California Title -24 and WA Ventilation Code. DC Motor Technology: When fan senses static pressure, its speed is automatically increased to ensure that the desired CFM is not compromised, which allows the fan to perform as rated. Adjustable Airflow for Maximum Performance FV -05-11 VK1 FV-05-11VK1 Static Pressure (inch w.g. Performance Curve 4" or 6" duct 0.80 0 20 10 60 BO 100 120 -- IIOCFM - I00CFM BOCFM - BOCFM 10CFM - BOCFM 50CFM 10CFM 00CFM Model Quantity Comments Project: Location: RECEIVED Architect: CITY OF TUKWIL, Engineer: Contractor: NOV 0 9 2018 Submitted by: 'ERAIII Date: i CENTER For complete Installation Instructions visit us.panasonic.com/ventfans Whisper se(eer VENTILATION FAN Plug 'N PIayTM Modules Adjustable Airflow for Maximum Performance FV -05-1 1 VK1 Plug 'N Play" modules provide up to three additional features. Select from Multi -Speed with Time Delay, Motion Sensor, Condensation Sensor and LED Night Light. FV-VS15VK1: Multi -Speed with Time Delay Allows you to select the proper CFM settings to satisfy ASHRAE 62.2 continuous ventilation requirements. The fan runs continuously at a pre-set lower level (0, 30-100 CFM, in 10 CFM increments), then elevates to a maximum level of operation (50-80-110 CFM) when the wall switch is turned on, or when the motion sensor or Condensation Sensor module is activated. A High/Low delay timer returns the fan to the pre-set CFM level after a period of time set by the user. FV-MSVK1: Motion Sensor Automatically activates when someone enters the room. Once the settings have been applied, the fan becomes truly automatic. oz:4This module also activates a 20 minute delay off timer for the fan. FV-CSVK1: Condensation Sensor Helps control bathroom condensation to prevent mold and mildew. Sensor technology detects relative humidity and temperature to anticipate dew point, automatically turning the fan on to control humidity. Built-in Relative Humidity (RH) sensitivity adjustment enables fine tuning for moist conditions and for satisfying CalGreen requirements. When the condensation sensor is used in conjunction with multi -speed functionality, the fan will kick up to high speed when the condensation sensor detects moisture in the room. This module also activates a 20 minute delay off timer for the fan. FV-NLVK1: LED Night Light A photocell automatically turns on the 1 watt LED night light when darkness is sensed in the room. High/Low brightness switch enables you to fine tune the photocell to work in conjunction with the darkness level of your bathroom. This module also activates an automatic 20 minute delay off timer for the fan. Fan Specifications Static Pressure in inches w.g. 0.1 WhisperGreen 0.25 Select'" 0.1 FV-05-11VK1 0.25 0.1 0.25 Air Volume (CFM) 110 113 80 82 50 53 Noise (sones) <0.3 0.8 <0.3 0.4 <0.3 <0.3 Power Consumption (watts) 9.8 16.1 5.4 10.2 3.2 6.5 Energy Efficiency (CFM/Watt) 11.5 7.2 15.3 8.4 15.1 8.1 Speed (RPM) 931 1205 814 1131 747 1072 Current (amps) 0.10 0.16 0.06 0.10 0.04 0.07 MAX. Current(amps) 0.27 Power Rating (V/Hz) 120/60 ENERGY STAR rated Yes 0.25=Installed Performance Fan Specifications WhisperGreen Select'": FV -05-11 VK1 + FV-VS15VK1 (Multi Speed Plug 'N Play" Module) Static Pressure in inches w.g. 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25 Air Volume (CFM) 110 113 100 106 90 95 80 82 70 71 60 66 50 53 40 43 30 33 Noise (sones) <0.3 0.8 <0.3 0.7 <0.3 0.6 <0.3 0.4 <0.3 0.4 <0.3 0.3 <0.3 <0.3 <0.3 <0.3 <0.3 <0.3 Power Consumption (watts) 9.8 16.1 8.0 14.0 6.5 11.7 5.5 10.2 4.3 8.6 3.6 7.8 3.2 6.5 2.7 5.7 2.4 5.0 Energy Efficiency (CFM/Watt) 11.5 7.2 13.0 7.9 14.5 8.5 15.3 8.4 17.2 8.7 17.5 8.8 15.1 8.1 16.3 8.2 14.2 7.6 Speed (RPM) 931 1205 895 1179 852 1146 814 1131 772 1112 750 1107 747 1072 731 1073 718 1062 Current (amps) 0.10 0.16 0.09 0.14 0.07 0.12 0.06 0.10 0.05 0.09 0.04 0.08 -0.04 0.07 0.08 0.06 0.03 0.06 MAX. Current(amps) 0.27 Power Rating (V/Hz) 120/60 ENERGY STAR rated Yes Panasonic Eco Solutions Company of North America Eco Products Division Two Riverfront Plaza Newark, NJ 07102 us.panasonic.com/ventfans Nvi0 c Y us `c.mna, VF16006SS0116 RECEIVED CITU OF TUKWILA NOV 0 9 2018 PERMIT CENTER 0.25=Installed Performance r1 Most Efficient 2016 gal= wrivemargyst.gor Panasonic � I COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M18-0146 DATE: 11/09/18 PROJECT NAME: MOUNTAIN VIEW APTS SITE ADDRESS: 14210 37 AVE S X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: po PM() Vtli Building Division Public Works ❑ Fire Prevention Structural Planning Division Permit Coordirrtor PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 11/13/18 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 12/11/18 Approved Corrections Required n Approved with Conditions n Fl Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 UCONS LLC Washington State Department of Labor & Industries Hoine Espanol Contact Safety & Health Claims & Insurance Page 1 of 2 Search L&I A -Z Index Help My L&.1 Workplace Rights Trades & Licensing UCONS LLC Owner or tradesperson Principals ECKHART, THOMAS G, PARTNER/MEMBER Doing business as UCONS LLC WA UBI No. 601 615 590 10612 NE 46TH ST KIRKLAND, WA 98033 425-576-8728 KING County Business type Limited Liability Company Governing persons DAVID R BALLE THOMAS GEORGE ECKHART; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. UCONSL*962RZ Effective — expiration 02/23/2005— 03/01/2019 Bond Active. Meets current requirements. American States Insurance Co $12,000.00 Bond account no. 32S204749 Received by L&I Effective date 05/05/2012 04/20/2012 Expiration date Until Canceled Insurance Unigard Indemnity Co $1,000,000.00 Policy no. CM011465 Received by L&I Effective date 08/29/2018 09/12/2012 Expiration date 09/12/2019 Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601615590&LIC=UCONSL*962RZ&SAW= 11/27/2018