Permit M18-0147 - ESSENDANT - ROOFTOP HEAT PUMP REPLACEMENT
ESSENDANT 18351 CASCADE AVE S EXPIRED 05/28/2019 M18-0147 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 7888900160 Permit Number: 18351 CASCADE AVE S Project Name: ESSENDANT Issue Date: Permit Expires On: M 18-0147 11/29/2018 5/28/2019 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: LIT KENT VALLEY 1717 MCKINNEY AV STE 1900, DALLAS, WA, 75202 JESSE CHUTICH 3202 C ST NE , AUBURN, WA, 98002 COMFORT MECHANICAL INC (CONSTRUCT) 3202 C ST NE , AUBURN, WA, 98002 COMFOM1015LA Phone: (425) 251-9840 Phone: (425) 251-9840 Expiration Date: 4/25/2020 DESCRIPTION OF WORK: REPLACE (1) 3 -TON ROOFTOP HEAT PUMP WITH NEW 3 TON HEAT PUMP. Valuation of Work: $5,827.00 Type of Work: REPLACEMENT Fuel type: ELECT Fees Collected: $285.78 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Permit Center Authorized Signature: Date: (1 -.)-1-1 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to gave authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: C Date: t V2 7: -/KY' This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 2: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 3: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 4: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 5: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 6: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 7: ***MECHANICAL PERMIT CONDITIONS*** 8: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 9: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov i Mechanical Permit No. M i g - Q) —1 4. Project No. Date Application Accepted: '' CI-- 1 6 Date Application Expires: 1 1 g (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address: 1113s- / C 0\S C, t t a V G S King Co Assessor's Tax No.: Suite Number: Tenant Name: ESS p/tdart� PROPERTY OWNER Name: '"`eSs 2 C jn �• T l c Name: LI 4. ke.n4 Va 1(6 Y City: A 4 k f a? Statee� ��//A Zip: Address: 1 g 3 a 1 c ce s 6o l e, alit S City: -'N It w; I a State: taA Zip: ail/ 23 CONTACT PERSON - person receiving all project communication Name: '"`eSs 2 C jn �• T l c Address: /20 ,L L S v • E City: A 4 k f a? Statee� ��//A Zip: Phone:2o 6 di 63 3 / 63 Fax: Email: � e.SSt.(4)C©#4,1'1ortn„ea" . Ge eh Floor: Roar New Tenant: ❑ Yes MECHANICAL CONTRACTOR INFORMATION Company Name: 00sifo,1 Aec'h o(n, c a 1 Address: 32 02 G s f N r City: Pl r C' rn State: `W ' Zip:q?OD 2. Phone: f z c- as. r Rg it ,Fax: Contr Reg No.60/4 rem T 0lcLAp Date: (,,/s/20 Tukwila Business No.: 3 4 s .- oer( 3 3,5 Valuation of project (contractor's bid price): $ 827 Describe the scope of work in detail: Ree/a.ct. (1) 3 ---ton 'oeffop hec.f pt„df„Q 1„// ✓tti„, Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement 2 Fuel Type: Electric -'fuel a 00- p h p. Gas ❑ Other: H:\ApplicationsiForms-Applications On Line\2016 Applications\Mechanical Permit Application Revised I-4-16.docx Revised: January 2016 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu ' Furnace >100k btu Industrial Floor furnace 55 dB(A) Suspended/wall/floor mounted heater 57 dB(A) Appliance vent Commercial Repair or addition to heat/refrig/cooling system 47 dB(A) Air handling unit 65 dB(A) <10,000 cfm 60 dB(A) Unit Type Qty Air handling unit Residential, Nighttime >10,000 cfm Industrial Evaporator cooler 55 dB(A) Ventilation fan connected to single duct 57 dB(A) Ventilation system Commercial Hood and duct 47 dB(A) Incinerator — domestic 65 dB(A) Incinerator — comm/industrial 60 dB(A) Unit Type Qty Fire damper Residential, Nighttime Diffuser Industrial Thermostat 55 dB(A) Wood/gas stove 57 dB(A) Emergency generator Commercial Other mechanical equipment 47 dB(A) 60 dB(A) 65 dB(A) Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-10PM, Monday through Friday and 8AM-10PM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: • Warning devices; • Construction and property maintenance during the daytime hours (7am-lOpm); • Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OW AUTHORIZED AGENT: Signature: Print Name: V -SS I c't/ral Date: 1'A 3A d Day Telephone: Mailing Address: City H:\ApplicationsiForms-Applications On Line\2016 Applications Mechanical Permit Application Revised I-4-16,docx Revised: January 2016 bh State Zip Page 2 of 2 DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $285.78 M18-0147 Address: 18351 CASCADE AVE S Apn: 7888900160 $285.78 Credit Card Fee $8.32 Credit Card Fee R000.369.908.00.00 0.00 $8.32 MECHANICAL $266.79 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $180.28 PLAN CHECK FEE R000.322.102.00.00 0.00 $53.36 TECHNOLOGY FEE $10.67 TECHNOLOGY FEE TOTAL FEESPAID BY RECEIPT: R15833 R000.322.900.04.00 0.00 $10.67 $285.78 Date Paid: Wednesday, November 14, 2018 Paid By: JESSE CHUTICH Pay Method: CREDIT CARD 314162 Printed: Wednesday, November 14, 2018 11:26 1 of 1 AM . + 4 SYSTEMS . . CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA 0017340000802374464500 Date: 11/14/2018 11:26:11 AM CREDIT CARD SALE VISA CARD NUMBER: **********7666 K TRAN AMOUNT: $285.78 APPROVAL CD: 314162 RECORD #: 000 CLERK ID: jazzel X {CARDHOLDER'S SIGNATURE} I AGREE TO PAY THE ABOVE TOTAL AMOUNT ACCORDING TO THE CARD ISSUER AGREEMENT (MERCHANT AGREEMENT IF CREDIT VOUCHER) Thank you! Merchant Copy Page 1 of 2 https://classic.convergepay.com/V irtualMerchant/transaction.do?dispatchMethod=printTr... 11 /14/201 8 United Technologies SUBMITTAL Project United Stationers Date Tuesday, July 17, 2018 REVIEWED FOR CODE COMPLIANCE APPROVED NOV 21 2018 CTukwila plISIO N MIS - Oltft RECEP 'ED CITY OF TUKWILA NOV 14 2018 PERMIT CENTER Project: United Stationers Prepared By: 3T Pkg HP 07/17/2018 09:53AM 3T Pkg HP Tag Cover Sheet Unit Report Certified Drawing Performance Report Guide Specification Unit Feature Sheet Spec Sheet Packaged Rooftop Builder 1.49i Page 3 of 13 Project: United Stationers Prepared By: Unit Report For 3T Pkg HP 07/17/2018 09:53AM Unit Parameters Unit Unit Size:_...__.__._._____-_ Volts -Phase -Hertz: _-__. Heating Type. Duct Cfg:__Horizontal ______________50VT-C _36 (3 Tons) ....... --------- ----208-3-60 Heat Pump Supply / Horizontal Return Warranty Information 1 year warranty on parts______ 5 yearwarranty on compressor_._._-__.__ No optional warranties were selected. NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Dimensions (ft. in.) & Weight (1b.)*** Unit Length: --------- ....... ---------....... 4' 0.25" Unit Widfh: --- 3' 8.1875" Unit Height:----- .... ... -4' 0.75" *** Weights and Dimensions are approximate. Weight does not include roof curbs, unit packaging, field installed accessories or factory installed options. Approximate dimensions are provided primarily for shipping purposes. For exact dimensions and weights, refer to appropriate product data catalog. Total Operating Weight:___.__-___-__ 387 Ib (Net Price Ea.) $0 Ordering Information Part Number Description Quanti ty Master Price (ea.) 50VT-C36---5 Rooftop Unit _ 1 $8,421 Base Unit $8,421 Accessories CPCRKHTR008A00 240V Crankcase Heater 1 $61 CPHEATER056A02 7.5/10.0 kW, 208/230-3-60 volt, Electric Heater 1 $267 CPECOMZR012A00 Horizontal Economizer 1 $1,413 CPRLYKIT001A00 Economizer relay kit for heat pumps 1 $155 Packaged Rooftop Builder 1.49i Page 4 of 13 Certified Drawing for 3T Pkg HP a� c 0 y N a) ccs D N 0. 2 2 MIDI Or RAYR} IIIeIN 3 3 2. 3 3 s 3 3 3 i A 3 3 3 A 3 • T. r 9 3 3 A 3 3 5OVT500411 Al Page 5 of 13 Packaged Rooftop Builder 1.49i 11 mom I 22 _ totto � GSW I -- a=IUMNINa" 5OVT500411 Al Page 5 of 13 Packaged Rooftop Builder 1.49i MicroMetl Date: 8/10/2018 Weights: 471bs/21.32kg Units: Part Number: ECH-SPPLBSA-DJDH Submitted To: shumphries@airefco.com Job: Notes: Economizer - Standard Leak Rain Hood With Aluminum Filter, Economizer, Horizontal Orientation, Honeywell Jade W7220 Single Speed Electromechanical Controller, Adjustable Dry Bulb Sensor, Honeywell Actuator. Painted Barometric Relief, All Necessary Panels And Hardware Included. 1Filter Access Field Provided DuctIIIIIIIIIIIIIII IIIIIIIIII u`= �� IIIIIIIIIIIIIII i l (I�1III' Outside Air Damper IIIIIIIIIIIIIII II IIIIIIIIIIII /� IIIIIIIIIII Replacement • ' Panel oo 00 00, Y """ .4;419. Return Damper 0. 111111 4 281/2„ ,, 1 \ i � Rainhood;,,; 00 00 0, oo 00 ! ir"'” u,n Nil`� 24:mo' ,tiA;, 1/ 1 Control Box Optional 0876-0300 Relief Damper Field Mounted to 00 00 rr ,': ,;,'„' I for JADE Controller Return Duct 00 00 00 ,,,;,,,+ I Hood Filter SIDE VIEW Provided Filters (1)16"x24"x 1" (1)18"x 24"x 1" The Information contained in this drawing is the sole property of Micrometl Corporation. Any reproduction in part or whole without the written permission of Micrometl Corporation is prohibited. Indianapolis_3035 N. Shadeland Ave., Indianapolis, IN 46226_800.MMC.HVAC •• Sparks_905 Southern Way, Sparks, NV 89431_800.884.4MMC •• Longview_201 Kodak Blvd., Longview, TX 75602_903.248.4800 ®M iCroMet1 Date: 8/10/2018 Weights: 471bs/21.32kg Units: Part Number: ECH-SPPLBSA-DJDH Submitted To: shumphries@airefco.com Job: Notes: Economizer - Standard Leak Economizer, Rain Hood With Aluminum Filter, Compliant Economizer: Horizontal Orientation, Honeywell Jade W7220 Single Speed Electromechanical Controller, Adjustable Dry Bulb Sensor, Honeywell Actuator. Painted Barometric Relief, All Necessary Panels And Hardware Included. meet California Energy Commission Title 24-2013 / 2016 mandatory section 120.2. for Fault Detection and Diagnostic controls (JADE HJW10). meet ASHRAE 90A-2016 Fault Detection and Diagnosis requirements. IECC 2015 and IECC 2018 for Fault Detection and Diagnostic requirements. Note: IECC 2015 and IECC 2018 requires differential retum air sensor, models (Le_ DJXH) and must be ordered separately on others (i.e. DJDH, DJZH). installed trouble-free operation, eliminating slippage and binding associated with standard linkage_ aluminum water entrainment filters in the outside air section. water run-off. needed are provided. Honeywell W7220 JADE controller, mixed (supply) air temperature sensor, OA sensor in description, and spring-retum communicating actuator (some sensor as noted). is factory mounted to economizer is field installed in indoor blower fan section. (included in "-DJXH" and--DJZH" models or can be ordered separately - MicroMetl Part No. 9901 -2022 -DIFF) is field installed in retum duct_ 24 require the economizer controller be capable of reporting faults to a fault management application accessible by day-to-day operating or service locally on zone thermostats or in some codes other devices are acceptable. Refer to applicable code requirements and to MicroMeti instructions for 1. Title 24: Economizers 2. ASHRAE 90.1: Economizers 3. IECC: Economizers meet which is included in some Features: - Includes filter rack Field • Gear driven design for • Includes rainhood with • Rainhood is sloped for • All hamesses and plugs Notes: 1. Control systems include include differential return 2. JADE W7220 controller 3. Mixed (supply) air sensor 4. Differential retum sensor 5. ASHRAE, IECC, and Title personnel, or annunciated suggestions. The Information contained in this drawing is the sole properly of Micrometl Corporation. Any reproduction in part or whole without the written permission of Micrometl Corporation is prohibited. Indianapolis_3035 N. Shadeland Ave., Indianapolis, IN 46226_800.MMC.HVAC •• Sparks_905 Southem Way, Sparks, NV 89431_800.884.4MMC •• Longview 201 Kodak Blvd., Longview, TX 75602_903.248.4800 Performance Summary For 3T Pkg HP Project: United Stationers Prepared By: 07/17/2018 09:53AM Part Number:50VT-C36---5 14.00 Base Unit Dimensions Unit Length:-- -----------------__. ------- --48.3 n Unit Width: 44.2 in Unit Height: 48.8 in Total Operating Weight: 387 Ib Unit Unit Voltage -Phase -Hertz: 208-3-60 Air Discharge: Horizontal Fan Drive Type: Direct Actual Airflow: .... ______......... __ __ 1156 CFM Site Altitude' __._.._0 ft Cooling Performance Condenser Entering Air DB. 95.0 F Evaporator Entering Air DB. _80.0 F Evaporator Entering Air WB: -67.0 F Entering Air Enthalpy:__..______________________. 31.44 BTU/Ib Evaporator Leaving Air DB. 59.5 F Evaporator Leaving Air WB:__ 57.8 F Evaporator Leaving Air Enthalpy. 24.90 BTU/Ib Net Cooling Capacity:_____..__._______________ 34.00 MBH ---------------------------------------------------------------------------------------------------- -- Net Sensible Capacity:_ 25.54 MBH --------------------------------- Total Unit Power Input: 2.96 kW Heating Performance Outdoor Ambient Temperature:-------------• ...... --..... --...... _______ --....... --....... ----------------------------•• 47.0 F Entering Air Indoor Coil DB: 70.0 F Leaving Air Indoor Coil DB: ...... -•--•---------•---------------------------- ---- ------------------- -97.5 F Total Heating Capacity. 34.31 MBH Integrated Heating Capacity:._._.__.__.____.___._ 34.31 MBH Heating Power Input:2.78 kW --------------- ---- Electric Heating Capacity: 7.50 kW Unit Leaving Air Temp. 118.0 F Supply Fan External Static Pressure: - 0.55 in wg Options / Accessories Static Pressure Electric Heaters: -0.09 in wg Economizer: -0.11 in wg Wet Coil:._..0.09 in wg Total Application Static (ESP + Unit Opts/Acc.). 0.84 in wg Fan Motor Size. hp 3/4 NOTE: High Motor Speed, Horz Electrical Data MinimumVoltage:---- ------------- ---.... --.... --....... ..... _______ ....... ................ -......................... -_ _197 Maximum Voltage: - -253 Compressor RLA:...... --.... ___________ .............. -------------- -------------------- ------ 10.4 Compressor LRA. 73 Actual Electric Heater kW: -7.5 Electric Heater FLA:- 20.8 Outdoor Fan FLA (ea): 1 Indoor Fan Motor FLA. 6 Power Supply MCA: --44.2 Packaged Rooftop Builder 1.49i Page 6 of 13 Performance Summary For 3T Pkg HP Project: United Stationers Prepared By: 07/17/2018 09:53AM Power Supply MOCP (Fuse or HACR). _45 Control Panel SCCR: 5kA RMS at Rated Symmetrical Voltage Acoustics Sound Rating: — 74.0 db Sound Power Levels, db re 10E-12 Watts Discharge Inlet Outdoor 63 Hz NA NA NA 125 Hz NA NA 61.9 250 Hz NA NA 63.3 500 Hz NA NA 58.9 1000 Hz NA NA 59.9 2000 Hz NA NA 58.7 4000 Hz NA NA 56.2 8000 Hz NA NA 52.4 Advanced Acoustics Advanced Accoustics Parameters 1. Unit height above ground. 30.0 ft 2. Horizontal distance from unit to receiver 50.0 ft 3. Receiver height above ground:._.____._..... _______.__...... 5.7 ft 4. Height of obstruction: 0.0 ft 5. Horizontal distance from obstruction to receiver.0.0 ft 6. Horizontal distance from unit to obstruction. 0.0 ft Detailed Acoustics Information Octave Band Center Freq. Hz 6 3 1 2 5 2 5 0 5 0 0 1 k 2 k 4 k 8 k Overal I A 0 6 6 5 5 5 5 5 68.3 . 1 3 8 9 8 6 2 Lw 0 .. 9 3. 9 9 7 2 4 B - 4 5 5 5 5 5 5 65.2 2 5 4 5 9 9 7 1 LwA . 8 7 7 9 9. 2. 3 2 Packaged Rooftop Builder 1.49i Page 7 of 13 Performance Summary For 3T Pkg HP Project: United Stationers Prepared By: 07/17/2018 09:53AM C 0 2 3 2 2 2 2 2 35.9 . 9 0 6 7 6 3 0 Lp 0 . 5 9 5 5 3. 8 0 D - 1 2 2 2 2 2 1 32.8 2 3 2 3 7 7 4 8 LpA 6 . . . . 4 3 3 5 5 8 9 2 Legend A Sound Power Levels at Units Acoustic Center, Lw B A -Weighted Sound Power Levels at Units Acoustic Center, LwA C Sound Pressure Levels at Specific Distance from Unit, Lp D A -Weighted Sound Pressure Levels at Specific Distance from Unit, LpA Calculation methods used in this program are patterned after the ASHRAE Guide; other ASHRAE Publications and the AHRI Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program, it is assumed that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this, no assurances can be offered that thus software will always generate an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space, an Acoustical Engineer or a person with sound prediction expertise should be consulted. Packaged Rooftop Builder 1.49i Page 8 of 13 Project: United Stationers Prepared By: Guide Specification for 3T Pkg HP 07/17/2018 09:53AM HVAC Guide Specifications Packaged Heat Pump System Size Range: 2 to 5 Tons, Nominal Cooling Model Number: 50VT-C Part 1? General SYSTEM DESCRIPTION Outdoor, packaged, air-to-air heat pump unit utilizing a hermetic scroll compressor for cooling duty and optional electric heating. Unit shall discharge supply air vertically or horizontally as shown on contract drawings. Outdoor fan/coil section shall have a draw-thru design with vertical discharge for minimum sound levels. QUALITY ASSURANCE A. Unitshall be rated in accordance withAHRlStandards 210/240and 270. B. Unit shall be designed in accordance with UL Standard 1995. C. Unitshall be manufactured in a facility registered to ISO 9001 manufacturing qualitystandard. D. Unitshall be UL listed and c -UL certified as a total package forsafety requirements. E. Roof curb shall bedesigned to conform to NRCAStandards. F. Insulation and adhesives shall meet N FPA 90A requirements for flame spread and smoke generation. G. Cabinet insulation shall meetASHRAE Standard 62P. DELIVERY, STORAGE AND HANDLING Unitshall be stored and handled per manufacturer's recommendations. Part 2 3/4 Products EQUIPMENT A. General: Factory -assembled, single -piece, heat pump unit. Contained within theendosure shall be all factory wiring, piping, controls, refrigerant charge (R -410A), and special features required priorto field start-up. B. UnitCabinet: 1. Unit cabinet shall be constructed of phosphated, zinc -coated, pre -painted steel capable ofwithstanding 500 hours of salt spray. 2. Normal serviceshall bethrough 3 removable cabinetpanels. 3. The unit shall be constructed on a rustproof unit base that has an externally trapped, integrated sloped drain. 4. Indoor fan compartment top surface shall be insulated with a minimum 1/2 -in. (13 mm) thick, flexible fiberglass insulation, coated on the airside and retained by adhesive and mechanical means. The indoor wall sections will be insulated with a minimum semi-rigid, foil -faced board capable of being wiped clean. Aluminum foil -faced fiberglass insulation shall be used in the entire indoor aircavity section. 5. Unitshall have a field -supplied condensatetrap. 6. Metal Insulated DuctCovers for side discharge will be standard on all sizes. 7. Unit insulationconformstoASHRAE62P. Packaged Rooftop Builder 1.49i Page 9 of 13 Guide Specification for 3T Pkg HP Project: United Stationers Prepared By: 07/17/2018 09:53AM C. Fans: 1. The indoorfan shall be 5 -speed, direct -drive, as shown on equipmentdrawings. 2. Fan wheel shall be made from steel and shall be double -inlet type with forward -curved blades with corrosion resistant finish. Fan wheel shall be dynamically balanced. 3. Outdoor fan shall be direct -drive, propeller -type with aluminum blades riveted to corrosion resistant steel spiders, be dynamically balanced, and discharge airvertically. D. Compressor. 1. Fully hermeticcompressorswith factory -installed vibration isolation. 2. Scroll compressors shall be standard on all units. E. Coils: Indoor and outdoor coils shall have aluminum plate fins mechanically bonded toseamless copper tubes with all joints brazed. Tube sheet openings shall be belled to preventtubewear. F. Refrigerant Metering Device: Refrigerant metering device shall be thermostaticexpansion valve orfixed orifice for cooling, and fixed orifice for heating. G. Filters: Filter section shall consistof field -installed, throwaway, 1 -in. (25 mm) -thick fiberglass filters of commercially available sizes. H. ControlsandSafeties: 1. Unit controls shall be complete with a self-contained, low -voltage control circuit. 2. Units shall incorporate an intemal compressor protectorthat provides reset capability. I. Operating Characteristics: 1. Unit shall be capable ofstarting and running at 125_F (51.7_C)ambientoutdoortemperature. 2. Compressor with standard controls shall be capable of operation down to 40 _F (4.4_C) ambientoutdoortemperature in cooling mode. 3. Unitshall be provided with 90 -second fan time delay afterthethermostatis satisfied. J. Electrical Requirements: All unitpowerwiring shall enter the unit cabinet ata single location. K. Motors: 1. Compressor motors shall be ofthe refrigerant -cooled type with line -break thermal and current overload protection. 2. All fan motors shall have permanently lubricated bearings, and inherent, automatic reset, thermal overload protection. 3. Condenserfanmotorshall betotally enclosed. 4. Evaporator fan motorto be ECM Motor. L. Special FeaturesAvailable: 1. Coil Options: Base unitwith tin plated indoor coil hairpins available as a factory installed option. 2. Compressor Start Kit (single phase units only): Shall provide additional starting torque for single-phase compressors. GUIDE SPECIFICATIONS (CONT) 3. Thermostat To provide fortwo-stage heating and one -stage cooling in addition manual or automatic changeover and indoorfan control. 4. Crankcase Heater: Shall provide anti-floodback protection for lowload cooling applications. 5. Economizer. (Horizontal - Field installed accessory) (Vertical - Field installed accessory) a Economizer controls capable of providing free cooling using outside air. b. Equipped with low leakage dampers not to exceed 3% leakage, at 1.0 I N. W.C. pressure differential. c Spring retum motor shuts offoutdoordamperon powerfailure. 6. Electric Heaters a Electric heater shall be available as a field installed option. b. Heaterelements shall be open wiretype, adequatelysupported and insulated with ceramic bushings. c. Electric heater packages must provide single point power connection capability. 7. Filter Rack Kit: Shall provide filter mounting fordownflowapplications. Offered as a field installed accessory. 8. Flat Roof Curb: Curbs shall have seal strip and awood nailerforflashing and shall be installed per manufacturers instructions. 9. Low Ambient Package: Shall consist of a solid-state control and outdoor coiltemperature sensor for controlling outdoor -fan motor operation, which shall allow unit to operate down to 0_F (-17.7_C) outdoorambienttemperature. 10. Manual Outdoor Air Damper: Packaged Rooftop Builder 1.49i Page 10 of 13 Guide Specification for 3T Pkg HP Project: United Stationers Prepared By: 07/17/2018 09:53AM Package shall consistofdamper, birdscreen, and rainhood which can be presetto admit outdoor airforyear-round ventilation. 11. Square -To -Round Duct Transitions (24-48 size): Shall have the ability to convertthe supply and return openingsfrom rectangularto round. 12. Time Guard II Automatically prevents the compressor from restarting for at least 4 minutes and 45 seconds after shutdown ofthecompressor. Not required when a corporate programmable thermostat is applied orwith a RTU -MP control. Offered as a field installed accessory. 13. Dual Point Electric Heaters! Allows you to power the electric heater and unit contactor separately by having two individual field power supply circuits connected respectively. 14. Cabinet Leakage Certified toleak2% or less of nominal air conditioning CFM delivered when pressurized to 1 -in. W.C. With all present air inlets, air outlets, and condensate drain port(s) sealed. Available as a factory installed option. 15. Louver Metal Outdoor Coil Grille Shall provide hail and vandalism protection. Available as afactory installed option and afield installed accessory. Packaged Rooftop Builder 1.49i Page 11 of 13 STRUCTURAL CALCULATIONS Essendant RTU 18351 Cascade Avenue Tukwila, Washington NOVEMBER 12, 2018 REVIEWED t=FOR CODE COMPLIANCE APPROVED NOV 21 2018 City of Tukwila BUILDING DIVISION 4((3. 0 iu� PREPARED FOR: Comfort Mechanical 3202 C Street NE Auburn, Washington 98002 PREPARED Bit: Moore Engineering Group 21902 96th Avenue SE Snohomish, Washington oore ngineering RECEIVED �,��� CITY OF TUKWILA NOV 14 2018 'EFIGOT CENTER GENERAL STRUCTURAL NOTES: 1. ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THESE NOTES AND THE INTERNATIONAL BUILDING CODE (IBC), 2015 EDITION. 2. DESIGN LOADING CRITERIA: ROOF LIVE LOAD 25 PSF MECHANICAL UNIT 482 POUNDS EARTHQUAKE SDS = 0.900 SITE CLASS D to E WIND 110 MPH, EXPOSURE B 3. STRUCTURAL CALCULATIONS AND SKETCHES SHALL BE USED IN CONJUNCTION WITH MECHANICAL DRAWINGS FOR BIDDING AND CONSTRUCTION. CONTRACTOR SHALL VERIFY DIMENSIONS AND CONDITIONS FOR COMPATIBILITY AND SHALL NOTIFY ENGINEER OF ALL DISCREPANCIES PRIOR TO CONSTRUCTION. 4. CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS, MEMBER SIZES AND CONDITIONS PRIOR TO COMMENCING ANY WORK. ALL DIMENSIONS OF EXISTING CONSTRUCTION SHOWN ARE INTENDED AS GUIDELINES ONLY AND MUST BE VERIFIED. THE EXISTING CONDITIONS SHOWN ON THE SKETCHES ARE BASED EITHER ON SITE OBSERVATION, ORIGINAL DRAWINGS OR WERE ASSUMED BASED ON EXPECTED CONDITIONS. IF THE EXISTING CONDITIONS DO NOT CLOSELY MATCH THE CONDITIONS SHOWN ON THE SKETCHES, OR IF THE EXISTING MATERIALS ARE OF QUESTIONABLE OR SUBSTANDARD QUALITY, NOTIFY THE ENGINEER PRIOR TO COMMENCING ANY WORK. 5. CONTRACTOR SHALL PROVIDE TEMPORARY BRACING FOR THE STRUCTURE AND STRUCTURAL COMPONENTS UNTIL ALL FINAL CONNECTIONS HAVE BEEN COMPLETED IN ACCORDANCE WITH THE DRAWINGS. 6. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES REQU]RED FOR THE COMPLETION OF THE WORK. 7. FRAMING LUMBER SHALL BE KILN DRIED OR MC -19, AND GRADED AND MARKED IN CONFORMANCE WITH W.C.L.B. STANDARD GRADING RULES FOR WEST COAST LUMBER NO. 17. FURNISH TO THE FOLLOWING MINIMUM STANDARDS: JOISTS: (2x MEMBERS) HEM -FIR NO. 2 Fb = 850 PSI, Fv = 150 PSI 8. TIMBER CONNECTORS CALLED OUT BY LETTERS AND NUMBERS SHALL BE "STRONG - TIE" BY SIMPSON COMPANY, AS SPECIFIED IN THEIR CATALOG NO. C -C-2017. INSTALL NUMBER AND SIZE OF FASTENERS AS SPECIFIED BY MANUFACTURER. CONNECTORS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. 9. SHEET METAL SCREWS SHALL CONFORM TO THE AMERICAN IRON AND STEEL INSTITUTE (AISI) "SPECIFICATIONS FOR THE DESIGN OF COLD -FORMED STEEL STRUCTURAL MEMBERS". 10. WOOD SCREWS SHALL CONFORM TO ANSI/ASME STANDARD B18.6.1. 11. METAL STRAPS FOR ANCHORAGE OF MECHANICAL UNITS SHALL CONFORM TO ASTM A446 GRADE A WITH A MINIMUM YIELD STRESS OF 33 KIPS PER. SQUARE INCH. 12. NAILS UTILIZED SHALL HAVE THE FOLLOWING MINIMUM PROPERTIES: NAIL 8d 10d 16d SHANK DIAMETER 0.131" 0.148' 0.148" HEAD DIAMETER 0.281" 0.312" 0.344" MINIMUM LENGTH 2-1/2" 3" 3-1/4" 13. PROVIDE 2x8 SUB -PURLINS AND HANGERS AS SHOWN ON THE ATTACHED PARTIAL ROOF FRAMING PLAN. 14. CONNECT THE UNIT TO THE EXISTING WOOD SLEEPERS WITH FOUR (4) 18 GAGE x 2- 1/2" WIDE GALVANIZED METAL STRAPS WITH THREE (3) #12 x 2" LONG GALVANIZED WOOD SCREWS TO THE SLEEPERS AND THREE (3) #12 SHEET METAL SCREWS TO THE UNIT AT EACH STRAP. Moore Engineering Group PROJECT: sEr r L) ENGR: jAV DATE: + 02,71 5 SCALE: 64_ SHEET PROTECT DESCRIPTION: The project consists of the replacement of an existing rooftop mechanical unit. LOADS: LIVE DEAD DEAD + LIVE WIND SEISMIC EQUIPMENT Unit Ex. Sleeper Total Dimensions Roofing and re -roof 1/2" plywood sheathing 2x4 @ 24" on -center 4x16 @ 8' on -center Insulation MEP Ceiling & Lights Total Dead 110 mph, Exposure B Latitude Longitude Site Class SDS (D) = SDs (E) = SDS = Existing RTU -1 280 95 375 pounds 4.0 1.5 0.7 1.8 1.0 2.0 2.0 13 25 PSF 38 PSF 47.437 -122.25 D to E WA DNR 0.947 0.852 0.900 New RTU -1 387 95 482 pounds 48"x45"x53" high Moore Engineering Group PROJECT: ESSENDANT RTU ENGR: KWM DATE: 1 1 / 12/ 18 SCALE: SHEET 11/10/2018 ion at LEGS Design Maps Summary Report User -Specified Input Design Maps Summary Report Report Title Essendant RTU Sat November 10, 2018 17:15:02 UTC Building Code Reference Document 2012/2015 International Building Code (which utilizes USGS hazard data available in 2008) Site Coordinates 47.437°N, 122.25°W Site Soil Classification Site Class D - "Stiff Soil" Risk Category I/II/III USGS-Provided Output Ss = 1.421 g Si = 0.530 g SMS = 1.421 g SMl = 0.795 g Sus = 0.947 g Sol = 0.530 g For information on how the SS and Si values above have been calculated from probabilistic (risk -targeted) and deterministic ground motions in the direction of maximum horizontal response, please return to the application and select the "2009 NEHRP" building code reference document. 3410Ea Response Spectrum Design Response Spectrum n..K, Oh? ONO I-3-10 1.31 PPrrina. T (Sc)e I.1S+ I(+? lAl Although this information is a product of the U.S. Geological Survey, we provide no warranty, expressed or implied, as to the accuracy of the data contained therein. This tool is not a substitute for technical subject -matter knowledge. haps://prod0l -earthquake.cr.usgs.gov/designmaps/us/summary.php?template=minimal&latitude=47.437&longitude=-1.2e.25&siteclass=3&riskcategory... 1/1 11/10/2018 ELS Design Maps Summary Report User -Specified Input Design Maps Summary Report Report Title Essendant RTU Sat November 10, 2018 17:15:26 UTC Building Code Reference Document 2012/2015 International Building Code (which utilizes USGS hazard data available in 2008) Site Coordinates 47.437°N, 122.25°W Site Soil Classification Site Class E - "Soft Clay Soil" Risk Category I/II/III USGS-Provided Output SS = 1.421 g Si = 0.530 g SMS = 1.278 g SM1 = 1.271 g Sos = 0.852 g s01 = 0.848 g For information on how the SS and S1 values above have been calculated from probabilistic (risk -targeted) and deterministic ground motions in the direction of maximum horizontal response, please return to the application and select the "2009 NEHRP" building code reference document. RMCEst Response Spectrum .:../, t11 (0fi nix'+ t 1 4 I 1 1 4 1 1 1 1.1.K1 int• t.S'I ii4n !ie) or) IXY.. 1.31 1.4 4A,) 1)4' 1C[I 43U111 )Period, T (see) )4I 0:72 Ill! 0,54 041 Iran t,. Design Response Spectrum 0.33 ,:.44. .363 O:il I ro La; Pc Iud. T (CCC) 1.111 I Sia 1 2.03 Although this information is a product of the U.S. Geological Survey, we provide no warranty, expressed or implied, as to the accuracy of the data contained therein. This tool is not a substitute for technical subject -matter knowledge. haps://prod0l-earthquake.cr.usgs.gov/designmaps/us/summary.php?template=minimal&latitude=47A37&longitude=-122.25&siteclass=4&riskcategory... 1/1 1111 mu ..„.r 0 L.5 •---V;1 v` 7 Q\ iz h-s i.0 4I› \i'l -'' CI 4 k 1 ,_. DIMENSIONAL DATA SPACER PANEL WCC042F AND WCCO6OF ONLY CORNER POST WCC042 AND OOOF ONLY CONDENSOR COIL WCC042F AND WCCD6OF ONLY NCCO18-06OF OUTLINE - REAR (ALL DIMENSIONS ARE IN INCHES) HORIZONTAL SUPPLY OPENING DOWNFL SUPPLY OPENING 4 SECT. X --X HORIZONTAL RETURN OPENING APPEARANCE SURFACE OF SUPPLY & RETURN PANEL TYPICAL CROSS SECTION OF HORIZONTAL SUPPLY & RETURN PERIMETER FLANGES NOTES: 1. SEE DRAWING D729946 FOR ISOMETRIC OUTLINE - FRONT. L 4 DIMENSIONAL SURFACE ISEE /ADM EVAPORATOR COIL & BLOWER PANEL CONDENSATE DRAIN FOR 3/4" FEMALE NPT ECONOMIZER/FILTER ACCESS PANEL DOWNFLOW RETURN OPENING SECT. Y -Y TYPICAL. CROSSPECTION OF DOWNFLOW SUPPLY & RETURN PERIMETER FLANGES MODEL COf081WE1GNT68% =law 0E114 A B C D E F d H J K L M b P W1 W2 W3 W4 66 55 72 87 `2801' 65-1/4 38 25-3/16 18.9/16 11.1/18 6-9/16 6.13/16 17 20-1/2 25 1 17-1/2 10 3 4.7)16 WDCO24F WCC030F 77 65 B9 105 • :• 335 ' 65-1/4 38 29-3116 18-9/18 11-1116 6.9/16 613/16 17 20.13/16 26.6/16 17.1/2 • 10 WCC036F 97 76 86 108 366 19 24-3/16 WCC0421 94 73 80 104 361 18-13/18 24 WCC048F 126 104 127 153 511 64-6/18 46 33-3/8 21.1/18 16-1/16 416/18 9.118 21-16/16 243/4 28 20 14 3 3-314 W0C0&OF 131 108 132 159 629 243/4 29 From Dwg. 210729988 Rev. 4 • 4 . no. 21X729085 P02 Q cv h O 0 Certified Drawing for 3T Pkg HP c111 or ci+vrtt ruw C C 0 S 5. 4 0 Y 0 5 S 0 X 0 7 2 0 0 3 2a 0 3 2 t 7 Y T A (AA 5.2 V E 6v a Ng:E t; geie .r .R Ogi R DM I &53 011 dill as:: Project: United Stationers Prepared By: Performance Summary For 3T Pkg HP 07/17/2018 09:53AM Part Number:50VT-C36---5 ARI SEER: 14.00 Base Unit Dimensions UnitLength:_ —--.._........._ — ......._ -- — - - _..._... — _........._... _ —48,.3 in Unit Width:—...._......... -- _..._......... -- _ - — -- -- 44.2 in Dk UnitHeight:.-----.._..__....._....._._..------_-_------------_..._..._.._..-.------___.... __—__..._--_.........__._. 48.8 in TotalOperating Weight' __._ _ __------•_-.....__----•-----._.._......-_--•---._........._..._.-_-.-__._....387 ib Unit Unit Voltage-Phase-Hertz:208-3-60 Air Discharge:_ .............._...___.._._-_._._ _Horizontal Fan Drive Type:.._—.---.__._..._..._.._..___-- Direct ActualAirflow:-----....._.._..._....._---------.._....._. _-_--_._..........__._.___.1156 CFM Site Altitude' __.__ ____0 ft Cooling Performance Condenser Entering Air DB:_..._.__. _........ _.—._.—......_. ____- 95,0 F Evaporator Entering Air DB' _8000 F Evaporator Entering Air WBS..___.. 67.0 F Entering Air Enthalpy:._— _..._—_.._._........._. 31.44 BTU/Ib EvaporatorLeaving Air DB' ___._._......_._.._-----....._._...._..___ _._...._......_...___._—.._.._.....__..- _59.5 F Evaporator Leaving Alr WB' __.__ __._.._........_. __._._57.8 F Evaporator Leaving Air Enthalpy:_......_....__.___ -_._..__....._.________ — _._------• ••••••--••••-____.____24.90 BTUIib Net Cooling Capacity- ty.34.00 MBH .. 25.54 MBH Net Sensible Capacity-------__........_.. -_.-____-- -_.--------_.__. _ Total Unit Power Input _.___.__....__.._____2.96 kW Coil Bypass Factor — ._......_.....__. — _.._.........._...-- -—._.._...._-- 0.047 Heating Performance Outdoor Ambient Temperature--_ —_ ____...47.0 F Entering Air Indoor Coil DB' 70.0 F Leaving Air Indoor Coil DB:.—_—_-•-- --_..._ ............._._ _.._----..._...._....--____-. _97.5 F Total Heating Capacity:..._..__....__.____—....___...._._.__. __._ _ 34.31 MBH Integrated Heating Capacity:___. _34.31 MBH Heating Power Input:.-----..__......_....----------_..._...._. —_—. _.. __.2.78 kW Electric Heating Capacity:_—..___.._ _.__._ _ _......_...._.___..__.__....7.50 kW Unit Leaving Air Temp: ----..____ ........... ..-----.._..._...__---118.0 F Supply Fan External Static Pressure—__._.._..._. 0.55 in wg Options / Accessories Static Pressure Electric Heaters:..._.._-- - ---- _ - ----..._...._....... - — .._...... ._.. -- _.... 0.09 in wg Economizer.._---._...._....-....._..—_._.._...._..._._-----.._.......---------..__....-.._—.___-_ --_9.11 In wg Wet Coil:_ -0.09 in wg Total Application Static (ESP + Unit Opts/Acc.) ..__.___ _..-0.84 in wg FanMotor Size, hp....-- - _.........._..... -- -- _ _ ----.._.. _ - ___.._...._......_---._............. 314 NOTE:_._..._....._--_--_...._-.-.__..__—._._ __._--._.._..........—__..__ _..High Motor Speed, Harz Electrical Data __ 197 Minimum Voltage' - - _.._ 257 Maximum Voltage:.—___ — _ .�-_253 CompressorRLA:_.____ _ ----- -- _74 10.4 Compressor LRA:—_._._ . '— Actual Electric Heater kW:_........._._._ ------__..__.._ ._------.._........-...-----,.-•....._..._. __7.5 Electric Heater FLA:._ _—• ___....._....___..._---•---._._.......__.._---20.8 OutdoorFan FLA (ea) ---_.__..._._.....__------____...._......._—___ __ _..---_....._........-----_.._..._.._._._1 IndoorFan Motor FtA:.___.--•--_.___...-----_..----------......_......_._—•_--_._-._._.__._..._..._.............---_--._. _..._6 Power Supply MCA:_-- ..... 44.2 Packaged Rooftop Builder 1.49i Page 6 of 13 4Y} Ulil r e /'L (1) F - X4 6:t3() 3.712- 474— v //4 = 6. 1 .Gi kiPrer4x.,_ 570 t3 017 Moore Engineering Group PROJECT: E:53e\ ,pec ENGR: DATE: j0211/15 SCALE; SHEET 4 ice �a `a 111 3 /1/eK.'25,4/ 3i I Moore Engineering Group PROJECT: fb ENGR: DATE: it ('Z/fin SCALE: 17/1,2_, SHEET 4/1/2019 City of Tukwila Department of Community Development JESSE CHUTICH 3202 C ST NE AUBURN, WA 98002 RE: Permit No. M18-0147 ESSENDANT 18351 CASCADE AVE S Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the Issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 5/28/2019. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 5/28/2019, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, (WCc. C),(.\? Kandace Nichols Permit Technician File No: M18-0147 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORS COPY: PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M18-0147 DATE: 11/14/18 PROJECT NAME: ESSENDANT SITE ADDRESS: 18351 CASCADE AVE S X Original Plan Submittal Response to Correction Letter # Revision # Revision # before Permit Issued after Permit Issued DEPARTMENTS: II 151 Y Pry DON 0 Building Division Public Works �n NPr uW6 Fire Prevention Planning Division Structural ❑ Permit Coordinator n PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 11/15/18 Structural Review Required REVIEWER'S INITIALS: DATE: n APPROVALS OR CORRECTIONS: Approved Approved with Conditions Corrections Required Denied (corrections entered in Reviews) (ie: Zoning Issues) DUE DATE: 12/13/18 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg D Fire ❑ Ping ❑ PW 0 Staff Initials: 12/18/2013 COMFORT MECHANICAL INC Home Espanol Contact Safety & Health Claims & Insurance Washington State Department of ki Labor & Industries Search L&I Page 1 of 2 A-Zlndex Help btyL&1 Workplace Rights Trades & Licensing COMFORT MECHANICAL INC Owner or tradesperson Principals JACKSON, SHIRLEY A, PRESIDENT JACKSON, HERB J, VICE PRESIDENT Doing business as COMFORT MECHANICAL INC WA UBI No. 601 954 041 3202 C ST NE AUBURN, WA 98002 425-251-9840 KING County Business type Corporation Governing persons HERB J JACKSON SHIRLEY A JACKSON; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties HeatingNent/Air-Conditioning and Refrig (HVAC/R) License no. COMFOMI015LA Effective — expiration 06/01/1999— 04/25/2020 Active. Meets current requirements. Bond Lexon Ins Co $6,000.00 Bond account no. 9815017 Received by L&I Effective date 06/04/2012 06/01/2012 Expiration date Until Canceled Insurance AMCO Ins Co $1,000,000.00 Policy no. ACP3008276478 Received by L&I Effective date 06/05/2018 06/01/2018 Expiration date 06/01/2019 Insurance history Savings Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601954041 &LIC=COMFOMI015LA&SAW= 11/29/2018 COMFORT MECHANICAL INC No savings accounts during the previous 61 3eriod. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID Account is current. 973,224-00 Doing business as COMFORT MECHANICAL INC Estimated workers reported Quarter 3 of Year 2018 "11 to 20 Workers" L&I account contact T3 / KENT ANDERSON (360)902-6963 - Email: ANDN235@Ini.wa.gcv Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health No inspections during the previous 6 year period. Page 2 of 2 Washington State Dept of Labor 8 Industries. Use of this site is subject to the laws or the state of Washington. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601954041 &LIC=COMFOMIO 1 5LA&SAW= 11/29/2018