HomeMy WebLinkAboutPermit M18-0152 - BOEING EMPLOYEES CREDIT UNION - DUCTLESS HEAT PUMP SPLIT SYSTEMBECU
12770 GATEWAY DR
M18-0152
Parcel No:
Address:
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-438-9350
Web site: http://www.TukwilaWA.gov
MECHANICAL PERMIT
2716000075 Permit Number:
12770 GATEWAY DR
Project Name: BECU
Issue Date:
Permit Expires On:
M 18-0152
12/4/2018
6/2/2019
Owner:
Name:
Address:
Contact Person:
Name:
Address:
BOEING EMPLOYEES CREDIT UNI
PO BOX 97050 , SEATTLE, WA, 98124
YAN DING
PO BOX 1455 , MONROE, WA, 98272
Contractor:
Name: PRECISE HEATING & COOLING LLC
Address: PO BOX 1455 , MONROE, WA, 98272
License No: PRECIHC891L9
Lender:
Name:
Address:
111
Phone: (425) 319-3428
Phone: (206) 861-2525
Expiration Date: 6/29/2019
DESCRIPTION OF WORK:
PROVIDE AND INSTALL 3 -2.5 TON WALL MOUNTED DUCTLESS HEAT PUMP SPLIT SYSTEM TO CONDITION THE
ELEVATOR MACHINE ROOM.
Valuation of Work: $15,680.00
Type of Work: NEW
Fuel type: ELECT
Fees Collected: $423.03
Electrical Service Provided by: SEATTLE CITY LIGHT
Water District: TUKWILA
Sewer District: TUKWILA
Current Codes adopted by the City of Tukwila:
International Building Code Edition:
International Residential Code Edition:
International Mechanical Code Edition:
Uniform Plumbing Code Edition:
International Fuel Gas Code:
Permit Center Authorized Signature:
2015
2015
2015
2015
2015
National Electrical Code:
WA Cities Electrical Code:
WAC 296-46B:
WA State Energy Code:
2017
2017
2017
2015
Date: lT ''1 - U
i •
I hearby certify that I have read and examined this permit and know the same to be true and correct. All
provisions of law and ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this
development permit and agree to the conditions attached to this permit.
Signature:
Print Name:
\Km tiv Gr
Date: f o- -fl/
This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if
the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: ***MECHANICAL PERMIT CONDITIONS***
2: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila
Permit Center (206/431-3670).
3: All permits, inspection record card and approved construction documents shall be kept at the site of work
and shall be open to inspection by the Building Inspector until final inspection approval is granted.
4: Manufacturers installation instructions shall be available on the job site at the time of inspection.
5: Except for direct -vent appliances that obtain all combustion air directly from the outdoors; fuel -fired
appliances shall not be located in, or obtain combustion air from, any of the following rooms or spaces:
Sleeping rooms, bathrooms, toilet rooms, storage closets, surgical rooms.
6: Equipment and appliances having an ignition source and located in hazardous locations and public garages,
PRIVATE GARAGES, repair garages, automotive motor -fuel dispensing facilities and parking garages shall be
elevated such that the source of ignition is not less than 18 inches above the floor surface on which the
equipment or appliance rests.
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206) 438-9350
1800 MECHANICAL FINAL
0701 ROUGH -IN MECHANICAL
CITY OF TUKWILA
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.Tukwi la WA . rgov
Mechanical Permit No.
Project No.
M IB-ois.)
Date Application Accepted:
Date Application Expires:
.5---10 -(9
(For office use only)
MECHANICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**please print**
SITE LOCATION
King Co Assessor's Tax No.: 2716000075
Site Address: 12770 Gateway Drive South, Tukwila, WA Suite Number: PENTHO Floor: ROOF
Tenant Name:
BUCU Tukwila Financial Center
PROPERTY OWNER
Name: YAN DING
Name: BOEING EMPLOYEES CREDIT UNI
Address: 12770 GATEWAY DR S
City: MONROE State: WA
City: Tukwila State: WA Zip:
98168
CONTACT PERSON — person receiving all project
communication
Name: YAN DING
Address: PO BOX 1455
Address: PO BOX 1455
City: MONROE State: WA
City: MONROE State: WA
Zip: 98272
Phone: (425) 319-3428 Fax:
Contr Reg No.: PRECIHC891L9 Exp Date:
Email: Yan@PreciseHeatandCool.com
Tukwila Business License No.: 00069050
New Tenant: ❑ Yes .. No
MECHANICAL CONTRACTOR INFORMATION
_
Company Name: PRECISE HEATING & COOLING L
Address: PO BOX 1455
City: MONROE State: WA
Zip: 98272
Phone: (206) 510-4250 Fax:
Contr Reg No.: PRECIHC891L9 Exp Date:
12/28/2019
Tukwila Business License No.: 00069050
Valuation of project (contractor's bid price): $
Describe the scope of work in detail:
Provide & install 3 - 2.5 Ton wall mounted ductless heat pump split system to condition the elevator machine room.
15,680
Use: Residential: New ❑ Replacement ❑
Commercial: New Replacement ❑
Fuel Type: Electric lit
Gas ❑ Other:
H:\Applications\Forms-.Applications On Line`2016 ApplicationsWechani al Permit Application Revised 1-4-16.docx
Revised: January 2016
hh
Page 1 of 2
Indicate type of mechanical work being installed and the quantity below:
Unit Type
Qts
Furnace <100k btu
Furnace >100k btu
Floor furnace
I
Suspended'wal lltloor
mounted heater_ _-
•• Appliance vent
Repair or addition to
heat, refrigt cool in g
! system
! Air handling unit
<10,000 cfm
Unit Type
Qty
Air handling unit
Residential, Nighttime
->10,000 cfm
Industrial
t
55 dB(A)
Evaporator cooler
57 dB(A)
Ventilation fan
connected to single duct
Cotntnercial
Ventilation system
47 dB(A)
Hood and duct
65 dB(A)
Incinerator -- domestic
60 dB(A)
hrcinerator •
counnrindustrial
65 dB(A)
Unit Type
Qty
Fire damper
Diffuser
Thermostat
Wood gas stove
Emergency generator -
Other mechanical
equipment
Boiler/Compressor
Qty
0-3 hp' 100.000 btu
Residential, Nighttime
3-15 hp/500,000 btu
Industrial
15-30 hp%1.000,000 btu
55 dB(A)
30-50 hp/ 1,750,000 btu
57 dB(A)
50-- hp'I,750,000 btu
Cotntnercial
57 dB(A)
47 dB(A)
60 dB(A)
65 dB(A)
Noise:
Mechanical units need to be in compliance with the Tukwila Noise Code. Maximus permissible sound levels are based on from where the sound is
created and where the sound is heard. Additionally . if sound can be heard from within a house at night in a residential zone it may not be allowed.
For more details. see TMC 8.22
District of Sound
Producing Source
District of Receiving Property
Residential_ Daytime*
Residential, Nighttime
Commercial
Industrial
Residential
55 dB(A)
45 dB(A)
57 dB(A)
60 dB(A)
Cotntnercial
57 dB(A)
47 dB(A)
60 dB(A)
65 dB(A)
Industrial
60 dB(A)
50 dB(A)
65 dB(A)
70 dB(A)
*Daytime means 7AM-10PM., Monday through Friday and 8AM-10PM. Saturday, Sunday a Id State -recognized holidays.
A few sounds are exempt from the noise code. including:
• Warning devices;
• Construction and property maintenance during the daytime hours (lam-lOpm);
• Testing of backup generators during the day.
PERMIT APPLICATION NOTES -
Value of construction — in all cases. a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the permit center to comply with current fee schedules.
Expiration of plan review - applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The building official may grant one extension of time for additional periods not to exceed 90 dans each. The extension shall be requested in writing
and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT I I-IAVE READ AND EXAMINED THIS APPLICATION AND KNOW TI IE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON. AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR AUTHORIZED AGENT:
Signature: Date: 10/29/2018
Print Name: YAN DING
Mailing Address: PO Box 1455 Monroe, WA 98272
Day "telephone: (425) 319-3428
City
ti: ApplicationslFomis-.4pplic.uions On Line 7016 Applications,Nlecluanicn1 Permit Application Revised 1-1-l6.dncx
Revised: January 2,016
btu
State Zip
Page 2 of 2
i
DESCRIPTIONS °_TM
PermitTRAK
ACCOUNT
f QUANTITY
PAID
$423.03
M18-0152 Address: 12770 GATEWAY DR
Apn: 2716000075
$423.03
Credit Card Fee
$12.32
Credit Card Fee
R000.369.908.00.00
0.00
$12.32
MECHANICAL
$394.91
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
0.00
$33.15
PERMIT FEE
R000.322.100.00.00
0.00
$282.78
PLAN CHECK FEE
R000.322.102.00.00
0.00
$78.98
TECHNOLOGY FEE
$15.80
TECHNOLOGY FEE
TOTAL FEES PAID BY RECEIPT: R15863
R000.322.900.04.00
0.00
$15.80
$423.03
Date Paid: Friday, November 16, 2018
Paid By: YAN DING
Pay Method: CREDIT CARD 04630G
Printed: Friday, November 16, 2018 2:32 PM 1 of 1
SYSTEMS
Page 2 of 2
CO TUKWILA ETRAKIT
6200 SOUTHCENTER BLVD
TUKWILA, WA 98188
206-433-1870
CITY OF TUKWILA
Date: 11/16/2018 02:31:54 PM
CREDIT CARD SALE
VISA
CARD NUMBER: **********7979 K
TRAN AMOUNT: $423.03
APPROVAL CD: 04630G
RECORD #: 000
CLERK ID: Bill
Thank you!
Customer Copy
https://classic.convergepay.com/VirtualMerchant/transaction. do?dispatchMethod=printTr... 11 /16/201 8
111 INSPECTION RECORD
Retain a copy with permit
INS 1IFE'• N NO. PERMIT N0.
CITY OF TUKWILA BUILDING DIVISION
(206) 431-3
•'� o/2.
6300 Southcenter Blvd., #100, Tukwila. WA 98188
Permit Inspection Request Line (206) 438-9350
ProjectV nig
WO
TI, �fInspect ;�Jived-
A dress:
/2770 iia
Date Called:
Special Instructions:
U
f
Date Wanted: a.m.
7-11—f p.m-
Requester:
L)e
Phone No: !q 2 y/ 7 P
Z04-
A
Approved per applicable codes. 0 Corrections required prior to approval.
COMMENTS j 3) 2,5 Tim/ 1. `4L` 141tou p\J1L# 4
kieed-P spCI- 5.W, ,_s. -11-0 ch•AsPi-iirk
712e iletigaer geloyet.
Mee°r L F;0AL
Inspector: al
„Qvafk...)
Date:
REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
406 d!s z
Project:
Type_Qt Inspection:
Address:
F 2_ C G
LJ ►ail 1 6✓?
Date Called:
Special Instructions:
Date Wanted:
3-ZZv- t9
a cri.
p.m.
Requester:
Phone No:
24t,
252
-
ElApproved per applicable codes. Corrections required prior to approval.
COMMENTS:
671_ I'Y��L,r it ri9L
Inspector:
Date:
I k REINSPECTION F E REQUIRED. Prior to next inspection. fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
High Wall Heat Pump Ductless System
Job Data:
Buyer:
Unit Number:
L..
Submittal Data
Buyer P.O. #:
Performance Data Certified By:
Pe
REVIEWED FOR
CODE COMPLIANCE
APPROVED
NOV 2 7 2018
t.()rritittififcrukwila
BUILD1NdUVISION
System
Size
30
Indoor Model
40MAQB30B-3
Electrical
Voltage, Phase, Cycle 1 V/Ph/Hz
208/230-1-60
Power Supply Indoor unit powered by outdoor unit
MCA 1 A.
0.4
Controls
Wireless Remote Controller (°F/°C Convertible)
Standard
Wired Remote Controller (°F/°C Convertible)
Optional
Operating
Range
Cooling Indoor DB Min -Max
°F(°C)
63-86 (17-30)
Heating Indoor DB Min -Max
°F(°C)
32-86 (0-30)
Piping
Pipe Connection Size - Liquid
in (mm)
3/8 (9.52)
Pipe Connection Size - Suction
in (mm)
5/8 (16)
Location:
Carrier #:
Model Number:I
Date:
STANDARD FEATURES
• Modes: Cool, Heat, Dry, Fan, Auto
• Turbo Mode
• Four fan speeds
• Sleep Mode
• Up -Down Louver control (fixed or swing)
• Follow Me (senses temperature at handheld remote)
- Heating Setback (46° F Heating Mode)
• Quiet indoor operation
• Aluminum Golden Hydrophilic pre -coated fins
CONTROLS:
• Wireless Remote Controller included with indoor unit
• Wired Remote Controller KSACNO401AAA (7 Day
programmable) (Optional)
LIMITED WARRANTY*
• 10 year limited to original purchaser on compressor and parts
upon timely registration, otherwise 5 years
*For residential applications. See warranty for full details.
Indoor Coil
Face Area 1 Sq. Ft.
3.68
No. Rows
3
Fins per inch
18
Circuits
7
Indoor
Unit Width
in (mm)
46.69 (1186)
Unit Height
in (mm)
13.39 (343)
Unit Depth
in (mm)
10.16 (258)
Net Weight
lbs (kg)
40.12 (18.2)
Number of Fan Speeds
4
Airflow (lowest to
highest)
CFM
520/620/780/870
Sound Pressure (lowest
to highest)
dB(A)
39/45/50
Air throw Data
ft (m)
36 (11)
Moisture removal
3int/h (L/I-
8.1 (3.9)
Field Drain Pipe Size O.0
in (mm)
0.625 (16)
Performance may vary based on the outdoor unit matched to. See compatible outdoor units pages for Performance Data.
For Compatibility See Product Data
Copyright 2018 Carrier Corporation • 7310 W. Morris St. Indianapolis. IN 46231
Edition Date: 03/2018
RECEIVED
CITY OF TUKWILA
NUV 16 2018
Catalog No: SUB40MAG-30-3-02
SUBJECT TO CHANGE WITHOUT NOTICE
MIA- 6IQ
1M! koLw$M
Replaces: SUB40MA0-30-3-01
Accessories
53DS-900---118
Condensate Pump (208230V)
KSACNO101 AAA
Wired Remote Control with Timer Function
KSACNO401AAA
Wired Remote Control 7 day Programmable*
KSAIF0301AAA
Wi-Film Kit High Wall Mid -Tier
KSAIC0101230
24V Interface Kit 230V
53DS-900---090
Wireless Remote Control Locking Mount Kit
Note: *KSACNO401AAA Wired Remote Control 7 Day programmable compatible with High Walls Units starting with Serial Number 0216V10001.
**24V Interface compatible with High Walls Units starting with Serial Number 4316V10001.
Construction View
Indoor Model: 40MAQB30B--3
Unit Width
in (mm)
46.69 (1186)
Unit Height
in (mm)
13.39 (343)
Unit Depth
in (mm)
10.16 (258)
Net Weight
lbs (kg)
40.12 (18.2)
Copyright 2018 Carrier Corporation • 7310 W. Moms St. Indianapolis. IN 46231
'PUS
Edition Date: 03/2018 Catalog No: SUB40MAQ-30-3-02
SUBJECT TO CHANGE WITHOUT NOTICE
Page 2
44.
Replaces: SUB40MAQ30-3-01
Outdoor 'Unit Single Zone Heat Pump Ductless System
Outdoor Model:
38MAQB30R--3
Job Data:
Buyer:
Unit Number:
Submittal Data
Buyer P.O. #:
Performance Data Certified By:
(111«torj'0AMMO
•s -..4p
•
NOTE: Images for illustration purposes only. Actual models may be slightly different
System
Size
30
Outdoor Model
38MAQB30R--3
Electrical
Voltage, Phase, Cycle
V/Ph/Hz
208/230-1-60
MCA
A.
20
MOCP - Fuse Rating
A.
30
Operating
Range
Cooling Outdoor DB Min - Max
°F(°C)
-13-122 (-25-50)
Heating Outdoor DB Min - Max
°F(°C)
-13-86 (-25-30)
Piping
Total Piping Length
ft (m)
164 (50)
Pining Lift"
ft (m)
82 (25)
Pipe Connection Size - Liquid
in (mm)
3/8 (9.52)
Pipe Connection Size - Suction
in (mm)
5/8 (16)
Refrigerant
Refrigerant Type
R410A
Metering Device
EEV
Charge 1 lbs (kg)
6.06 (2.75)
* Condensing unit above or below indoor unit
For Compatibility See Product Data
Copyright 2018 CAC/BDP • 7310 W. Morris St. Indianapolis. IN 46231
Location:
Carrier #:
Model Number:
Date:
STANDARD FEATURES
• Variable Speed (Inverter)
• Factory installed Base Pan Heater
• Factory installed Crankcase Heater
• Low Voltage Controls
• Auto -Restart function
• Condenser High Temp Protection
• Refrigerant Leakage Detection
• Modes: Cool, Heat, Dry, Fan, Auto
• Quiet operation
• Aluminum Golden Hydrophilic pre -coated fins
LIMITED WARRANTY*
• 10 year limited to original purchaser on compressor and
parts upon timely registration, otherwise 5 years
*For residential applications.
See warranty for full details.
Outdoor Coil
Face Area 1 Sq. Ft.
8.0
No. Rows
3
Fins per inch
18
Circuits
6
Compressor
Type
Rotary Inverter
Model
ATF250D22UMT
Oil Type
VG74
Oil Charge
FI. Oz.
23.6
Rated Current
RLA
15.0
Outdoor
Unit Width
in (mm)
37.24 (946)
Unit Height
in (mm)
31.89 (810)
Unit Depth
in (mm)
16.14 (410)
Net Weight
lbs (kg)
139.8 (63.4)
Airflow
CFM
2,130
Sound Pressure
dB(A)
60.5
Edition Date: 03/2018
Catalog No: 38MAR-30-3-04S8
SUBJECT TO CHANGE WITHOUT NOTICE Page 1
Replaces: 38 M A R-30-3.03 S B
Performance
High Wall
Indoor Model
40MAQB30B--3
Indoor Model
619PEQ030BBMA
Indoor Model
DHMSHAQ3OXA3
Energy Star
NO
Cooling Rated Capacity
Btu/h
30,000
Cooling Cap. Range Min - Max
Btu/h
8000-30500
SEER
19.8
EER
11.5
Heating Rated Capacity (47°F)
Btu/h
30,000
Heating Rated Capacity (17"F)
Btu/h
18,500
Heating Maximum Capacity (17°F)
Btu/h
18,500
Heating Maximum Capacity (5°F)
Btu/h
16,380
Heating Cap. Range Min - Max
Btu/h
9000-34000
HSPF
9.4
COP (47°F)
WNW
2.60
COP (17°F)
W/W
2.16
COP (5"F)
W/W
2.20
Vertical Fan Coil
Indoor Model
FFMANP031T00
Energy Star
NO
Cooling Rated Capacity
Btu/h
30,000
Cooling Cap. Range Min - Max
Btu/h
8000-31,600
SEER
17.0
EER
11.5
Heating Rated Capacity (47°F)
Btu/h
30,000
Heating Rated Capacity (17°F)
Btu/h
21,400
Heating Maximum Capacity (17"F)
Btu/h
21,300
Heating Maximum Capacity (5°F)
Btu/h
21,300
Heating Cap. Range Min - Max
Btu/h
9,000-31,800
HSPF
10.0
COP (47°F)
W/W
3.50
COP (17°F)
W/W
2.12
COP (5°F)
W/W
1.96
Horizontal Fan Coil
Indoor Model
FPMBN*030T00
Energy Star
NO
Cooling Rated Capacity
Btu/h
30,000
Cooling Cap. Range Min - Max
Btu/h
8,000-30,600
SEER
15.0
EER
9.8
Heating Rated Capacity (47'F)
Btu/h
30,000
Heating Rated Capacity (17°F)
Btu/h
20,600
Heating Maximum Capacity (17T)
Btu/h
20,200
Heating Maximum Capacity (5"F)
Btu/h
19,200
Heating Cap. Range Min - Max
Btu/h
9000-30,600
HSPF
9.6
COP (47°F)
WAW
3.00
COP (17"F)
W/W
2.19
COP (5'F)
W/W
2.09
Copyright 2018 CAC/BDP • 7310 W. Morns St. Indianapolis. IN 46231
Edition Date: 03/2018 Catalog No: 38MAR-30-3-04S8
SUBJECT TO CHANGE WITHOUT NOTICE
Page 2 Replaces: 38MAR-30-303SB
•
Construction View
Outdoor Model: 38MAQB30R--3
Copyright 2018 CAC/BDP • 7310 W. Morris Si Indianapolis. IN 46231
.(E. ri)u
Edition Date: 03/2018
3.38 it
Catalog No: 38MAR-30-3-04SB
SUBJECT TO CHANGE WITHOUT NOTICE Page 3 Replaces: 38MAR-30-3-03SB
8/5/2019
City of Tukwila
Department of Community Development
YAN DING
PO BOX 1455
MONROE, WA 98272
RE: Permit No. M18-0152
BECU
12770 GATEWAY DR
Dear Permit Holder:
Allan Ekberg, Mayor
Jack Pace, Director
In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building
Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric
Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null
and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if
the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180
days. Your permit will expire on 9/21/2019.
Based on the above, you are hereby advised to:
1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or fmal inspection. Each
inspection creates a new 180 day period, provided the inspection shows progress.
-or-
2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire.
Address your extension request to the Building Official and state your reason(s) for the need to extend your permit.
The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your
extension request is granted, you will be notified by mail.
In the event you do not call for an inspection and/or receive an extension prior to 9/21/2019, your permit will become null and void
and any further work on the project will require a new permit and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
Kadace Nichols2
Permit Technician
File No: M18-0152
6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665
PERMIT COORD COPS -
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: M18-0152
PROJECT NAME: BECU
SITE ADDRESS: 12770 GATEWAY DR S
X Original Plan Submittal
Response to Correction Letter #
Revision #
DATE: 11/16/18
before Permit Issued
after Permit Issued
Revision #
DEPARTMENTS:
\\\1
;iti.(1(1?:1ing Division
Public Works
At'( N/4
Fire Prevention
Structural
n
PIanning Division
Permit Coordittor
to
PRELIMINARY REVIEW:
Not Applicable
(no approval/review required)
REVIEWER'S INITIALS:
DATE: 11/20/18
Structural Review Required
DATE:
APPROVALS OR CORRECTIONS:
Approved
Corrections Required
(corrections entered in Reviews)
Approved with Conditions
Denied
(ie: Zoning Issues)
DUE DATE: 12/18/18
n
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
12/18/2013
PRECISE HEATING & COOLING, -IX
}Tome Espanol Contact:
Safety & Health Claims & Insurance
Washington State Department of
�J Labor & Industries
Page 1 of 2
Fearch L&I
A -Z. Index I -I eIp My Lel
Workplace Rights Trades & Licensing
PRECISE HEATING & COOLING LLC
Owner or tradesperson
Principals
MOORE, LAMAR
RALPH, PARTNER/MEMBER
STRINGER, MICHAEL
LEE, PARTNER/MEMBER
(End: 04/24/2015)
Doing business as
PRECISE HEATING & COOLING LLC
WA UBI No.
603 122 887
PO BOX 1455
MONROE, WA 98272
206-861-2525
SNOHOMISH County
Business type
Limited Liability Company
Governing persons
LAMAR
MOORE
MICHAEL L STRINGER;
License
Verify the contractor's active registration / license / certification (depending on trade) and any past violations.
Construction Contractor Active.
..... ...........................
Meets current requirements.
License specialties
HeatingNent/Air-Conditioning and Refrig
(HVAC/R)
License no.
PRECIHC891 L9
Effective — expiration
06/29/2011— 06/29/2019
Bond
Wesco Insurance Co
Bond account no.
46WB043501
$6,000.00
Received by L&I Effective date
04/07/2014 04/20/2014
Expiration date
Until Canceled
Bond history
Insurance
Ohio Security Ins Co
Policy no.
BKS55371340
Received by L&I
11/08/2018
$1,000,000.00
Effective date
11/29/2016
Expiration date
Help us improve
https://secure.lni.wa.gov/verify/Detail.aspx?UBI=603122887&LIC=PRECIHC891 L9&SAW= 12/4/2018
PRECISE HEATING & COOLING LLC Page 2 of 2
11/29/2019
Insurance history
Savings
No savings accounts during the previous 6 year period.
Lawsuits against the bond or savings
No lawsuits against the bond or savings accounts during the previous 6 year period.
L&I Tax debts
.............
No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts
may be recorded by other agencies.
License Violations
Infraction no.
EJACH00852
Issue date
08/06/2015
Violation city
MONROE
Type of violation
ELECTRICAL CITATION
Description
Offering, bidding, advertising, or performing
electrical installations, alterations or
maintenance outside the scope of the firm's
specialty electrical contractors license.
(Installing low voltage conductors at a
commercial site)
Satisfied
..............
RCW/WAC
19.28.041 RCW
Violation amount
$500.00
Workers' comp
Do you know if the business has empioyees? If so, verify the business is up-to-date on workers' comp premiums.
L&I Account ID Account is current.
217,035-00
Doing business as
PRECISE HEATING & COOLING LLC
Estimated workers reported
Quarter 3 of Year 2018 "4 to 6 Workers"
L&I account contact
T4 / CASSANDRA SMITH (360)902-5632 - Email: SMCA235@lni.wa.gov
Public Works Strikes and Debarments
Verify the contractor is eligible to perform work on public works projects.
Contractor Strikes
No strikes have been issued against this contractor.
Contractors not allowed to bid
...........
No debarments have been issued against this contractor.
Workplace safety and health
No inspections during the previous 6 year period.
e? Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington.
Help us improve
https://secure.lni.wa.gov/verify/Detail.aspx?UBI=603122887&LIC=PRECIHC891 L9&SAW= 12/4/2018