Loading...
HomeMy WebLinkAboutPermit M18-0152 - BOEING EMPLOYEES CREDIT UNION - DUCTLESS HEAT PUMP SPLIT SYSTEMBECU 12770 GATEWAY DR M18-0152 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 2716000075 Permit Number: 12770 GATEWAY DR Project Name: BECU Issue Date: Permit Expires On: M 18-0152 12/4/2018 6/2/2019 Owner: Name: Address: Contact Person: Name: Address: BOEING EMPLOYEES CREDIT UNI PO BOX 97050 , SEATTLE, WA, 98124 YAN DING PO BOX 1455 , MONROE, WA, 98272 Contractor: Name: PRECISE HEATING & COOLING LLC Address: PO BOX 1455 , MONROE, WA, 98272 License No: PRECIHC891L9 Lender: Name: Address: 111 Phone: (425) 319-3428 Phone: (206) 861-2525 Expiration Date: 6/29/2019 DESCRIPTION OF WORK: PROVIDE AND INSTALL 3 -2.5 TON WALL MOUNTED DUCTLESS HEAT PUMP SPLIT SYSTEM TO CONDITION THE ELEVATOR MACHINE ROOM. Valuation of Work: $15,680.00 Type of Work: NEW Fuel type: ELECT Fees Collected: $423.03 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Date: lT ''1 - U i • I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: \Km tiv Gr Date: f o- -fl/ This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***MECHANICAL PERMIT CONDITIONS*** 2: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: Manufacturers installation instructions shall be available on the job site at the time of inspection. 5: Except for direct -vent appliances that obtain all combustion air directly from the outdoors; fuel -fired appliances shall not be located in, or obtain combustion air from, any of the following rooms or spaces: Sleeping rooms, bathrooms, toilet rooms, storage closets, surgical rooms. 6: Equipment and appliances having an ignition source and located in hazardous locations and public garages, PRIVATE GARAGES, repair garages, automotive motor -fuel dispensing facilities and parking garages shall be elevated such that the source of ignition is not less than 18 inches above the floor surface on which the equipment or appliance rests. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1800 MECHANICAL FINAL 0701 ROUGH -IN MECHANICAL CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.Tukwi la WA . rgov Mechanical Permit No. Project No. M IB-ois.) Date Application Accepted: Date Application Expires: .5---10 -(9 (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION King Co Assessor's Tax No.: 2716000075 Site Address: 12770 Gateway Drive South, Tukwila, WA Suite Number: PENTHO Floor: ROOF Tenant Name: BUCU Tukwila Financial Center PROPERTY OWNER Name: YAN DING Name: BOEING EMPLOYEES CREDIT UNI Address: 12770 GATEWAY DR S City: MONROE State: WA City: Tukwila State: WA Zip: 98168 CONTACT PERSON — person receiving all project communication Name: YAN DING Address: PO BOX 1455 Address: PO BOX 1455 City: MONROE State: WA City: MONROE State: WA Zip: 98272 Phone: (425) 319-3428 Fax: Contr Reg No.: PRECIHC891L9 Exp Date: Email: Yan@PreciseHeatandCool.com Tukwila Business License No.: 00069050 New Tenant: ❑ Yes .. No MECHANICAL CONTRACTOR INFORMATION _ Company Name: PRECISE HEATING & COOLING L Address: PO BOX 1455 City: MONROE State: WA Zip: 98272 Phone: (206) 510-4250 Fax: Contr Reg No.: PRECIHC891L9 Exp Date: 12/28/2019 Tukwila Business License No.: 00069050 Valuation of project (contractor's bid price): $ Describe the scope of work in detail: Provide & install 3 - 2.5 Ton wall mounted ductless heat pump split system to condition the elevator machine room. 15,680 Use: Residential: New ❑ Replacement ❑ Commercial: New Replacement ❑ Fuel Type: Electric lit Gas ❑ Other: H:\Applications\Forms-.Applications On Line`2016 ApplicationsWechani al Permit Application Revised 1-4-16.docx Revised: January 2016 hh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qts Furnace <100k btu Furnace >100k btu Floor furnace I Suspended'wal lltloor mounted heater_ _- •• Appliance vent Repair or addition to heat, refrigt cool in g ! system ! Air handling unit <10,000 cfm Unit Type Qty Air handling unit Residential, Nighttime ->10,000 cfm Industrial t 55 dB(A) Evaporator cooler 57 dB(A) Ventilation fan connected to single duct Cotntnercial Ventilation system 47 dB(A) Hood and duct 65 dB(A) Incinerator -- domestic 60 dB(A) hrcinerator • counnrindustrial 65 dB(A) Unit Type Qty Fire damper Diffuser Thermostat Wood gas stove Emergency generator - Other mechanical equipment Boiler/Compressor Qty 0-3 hp' 100.000 btu Residential, Nighttime 3-15 hp/500,000 btu Industrial 15-30 hp%1.000,000 btu 55 dB(A) 30-50 hp/ 1,750,000 btu 57 dB(A) 50-- hp'I,750,000 btu Cotntnercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximus permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally . if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details. see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential_ Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Cotntnercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-10PM., Monday through Friday and 8AM-10PM. Saturday, Sunday a Id State -recognized holidays. A few sounds are exempt from the noise code. including: • Warning devices; • Construction and property maintenance during the daytime hours (lam-lOpm); • Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases. a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review - applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 dans each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I I-IAVE READ AND EXAMINED THIS APPLICATION AND KNOW TI IE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON. AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Date: 10/29/2018 Print Name: YAN DING Mailing Address: PO Box 1455 Monroe, WA 98272 Day "telephone: (425) 319-3428 City ti: ApplicationslFomis-.4pplic.uions On Line 7016 Applications,Nlecluanicn1 Permit Application Revised 1-1-l6.dncx Revised: January 2,016 btu State Zip Page 2 of 2 i DESCRIPTIONS °_TM PermitTRAK ACCOUNT f QUANTITY PAID $423.03 M18-0152 Address: 12770 GATEWAY DR Apn: 2716000075 $423.03 Credit Card Fee $12.32 Credit Card Fee R000.369.908.00.00 0.00 $12.32 MECHANICAL $394.91 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $282.78 PLAN CHECK FEE R000.322.102.00.00 0.00 $78.98 TECHNOLOGY FEE $15.80 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R15863 R000.322.900.04.00 0.00 $15.80 $423.03 Date Paid: Friday, November 16, 2018 Paid By: YAN DING Pay Method: CREDIT CARD 04630G Printed: Friday, November 16, 2018 2:32 PM 1 of 1 SYSTEMS Page 2 of 2 CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA Date: 11/16/2018 02:31:54 PM CREDIT CARD SALE VISA CARD NUMBER: **********7979 K TRAN AMOUNT: $423.03 APPROVAL CD: 04630G RECORD #: 000 CLERK ID: Bill Thank you! Customer Copy https://classic.convergepay.com/VirtualMerchant/transaction. do?dispatchMethod=printTr... 11 /16/201 8 111 INSPECTION RECORD Retain a copy with permit INS 1IFE'• N NO. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION (206) 431-3 •'� o/2. 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 ProjectV nig WO TI, �fInspect ;�Jived- A dress: /2770 iia Date Called: Special Instructions: U f Date Wanted: a.m. 7-11—f p.m- Requester: L)e Phone No: !q 2 y/ 7 P Z04- A Approved per applicable codes. 0 Corrections required prior to approval. COMMENTS j 3) 2,5 Tim/ 1. `4L` 141tou p\J1L# 4 kieed-P spCI- 5.W, ,_s. -11-0 ch•AsPi-iirk 712e iletigaer geloyet. Mee°r L F;0AL Inspector: al „Qvafk...) Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 406 d!s z Project: Type_Qt Inspection: Address: F 2_ C G LJ ►ail 1 6✓? Date Called: Special Instructions: Date Wanted: 3-ZZv- t9 a cri. p.m. Requester: Phone No: 24t, 252 - ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: 671_ I'Y��L,r it ri9L Inspector: Date: I k REINSPECTION F E REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. High Wall Heat Pump Ductless System Job Data: Buyer: Unit Number: L.. Submittal Data Buyer P.O. #: Performance Data Certified By: Pe REVIEWED FOR CODE COMPLIANCE APPROVED NOV 2 7 2018 t.()rritittififcrukwila BUILD1NdUVISION System Size 30 Indoor Model 40MAQB30B-3 Electrical Voltage, Phase, Cycle 1 V/Ph/Hz 208/230-1-60 Power Supply Indoor unit powered by outdoor unit MCA 1 A. 0.4 Controls Wireless Remote Controller (°F/°C Convertible) Standard Wired Remote Controller (°F/°C Convertible) Optional Operating Range Cooling Indoor DB Min -Max °F(°C) 63-86 (17-30) Heating Indoor DB Min -Max °F(°C) 32-86 (0-30) Piping Pipe Connection Size - Liquid in (mm) 3/8 (9.52) Pipe Connection Size - Suction in (mm) 5/8 (16) Location: Carrier #: Model Number:I Date: STANDARD FEATURES • Modes: Cool, Heat, Dry, Fan, Auto • Turbo Mode • Four fan speeds • Sleep Mode • Up -Down Louver control (fixed or swing) • Follow Me (senses temperature at handheld remote) - Heating Setback (46° F Heating Mode) • Quiet indoor operation • Aluminum Golden Hydrophilic pre -coated fins CONTROLS: • Wireless Remote Controller included with indoor unit • Wired Remote Controller KSACNO401AAA (7 Day programmable) (Optional) LIMITED WARRANTY* • 10 year limited to original purchaser on compressor and parts upon timely registration, otherwise 5 years *For residential applications. See warranty for full details. Indoor Coil Face Area 1 Sq. Ft. 3.68 No. Rows 3 Fins per inch 18 Circuits 7 Indoor Unit Width in (mm) 46.69 (1186) Unit Height in (mm) 13.39 (343) Unit Depth in (mm) 10.16 (258) Net Weight lbs (kg) 40.12 (18.2) Number of Fan Speeds 4 Airflow (lowest to highest) CFM 520/620/780/870 Sound Pressure (lowest to highest) dB(A) 39/45/50 Air throw Data ft (m) 36 (11) Moisture removal 3int/h (L/I- 8.1 (3.9) Field Drain Pipe Size O.0 in (mm) 0.625 (16) Performance may vary based on the outdoor unit matched to. See compatible outdoor units pages for Performance Data. For Compatibility See Product Data Copyright 2018 Carrier Corporation • 7310 W. Morris St. Indianapolis. IN 46231 Edition Date: 03/2018 RECEIVED CITY OF TUKWILA NUV 16 2018 Catalog No: SUB40MAG-30-3-02 SUBJECT TO CHANGE WITHOUT NOTICE MIA- 6IQ 1M! koLw$M Replaces: SUB40MA0-30-3-01 Accessories 53DS-900---118 Condensate Pump (208230V) KSACNO101 AAA Wired Remote Control with Timer Function KSACNO401AAA Wired Remote Control 7 day Programmable* KSAIF0301AAA Wi-Film Kit High Wall Mid -Tier KSAIC0101230 24V Interface Kit 230V 53DS-900---090 Wireless Remote Control Locking Mount Kit Note: *KSACNO401AAA Wired Remote Control 7 Day programmable compatible with High Walls Units starting with Serial Number 0216V10001. **24V Interface compatible with High Walls Units starting with Serial Number 4316V10001. Construction View Indoor Model: 40MAQB30B--3 Unit Width in (mm) 46.69 (1186) Unit Height in (mm) 13.39 (343) Unit Depth in (mm) 10.16 (258) Net Weight lbs (kg) 40.12 (18.2) Copyright 2018 Carrier Corporation • 7310 W. Moms St. Indianapolis. IN 46231 'PUS Edition Date: 03/2018 Catalog No: SUB40MAQ-30-3-02 SUBJECT TO CHANGE WITHOUT NOTICE Page 2 44. Replaces: SUB40MAQ30-3-01 Outdoor 'Unit Single Zone Heat Pump Ductless System Outdoor Model: 38MAQB30R--3 Job Data: Buyer: Unit Number: Submittal Data Buyer P.O. #: Performance Data Certified By: (111«torj'0AMMO •s -..4p • NOTE: Images for illustration purposes only. Actual models may be slightly different System Size 30 Outdoor Model 38MAQB30R--3 Electrical Voltage, Phase, Cycle V/Ph/Hz 208/230-1-60 MCA A. 20 MOCP - Fuse Rating A. 30 Operating Range Cooling Outdoor DB Min - Max °F(°C) -13-122 (-25-50) Heating Outdoor DB Min - Max °F(°C) -13-86 (-25-30) Piping Total Piping Length ft (m) 164 (50) Pining Lift" ft (m) 82 (25) Pipe Connection Size - Liquid in (mm) 3/8 (9.52) Pipe Connection Size - Suction in (mm) 5/8 (16) Refrigerant Refrigerant Type R410A Metering Device EEV Charge 1 lbs (kg) 6.06 (2.75) * Condensing unit above or below indoor unit For Compatibility See Product Data Copyright 2018 CAC/BDP • 7310 W. Morris St. Indianapolis. IN 46231 Location: Carrier #: Model Number: Date: STANDARD FEATURES • Variable Speed (Inverter) • Factory installed Base Pan Heater • Factory installed Crankcase Heater • Low Voltage Controls • Auto -Restart function • Condenser High Temp Protection • Refrigerant Leakage Detection • Modes: Cool, Heat, Dry, Fan, Auto • Quiet operation • Aluminum Golden Hydrophilic pre -coated fins LIMITED WARRANTY* • 10 year limited to original purchaser on compressor and parts upon timely registration, otherwise 5 years *For residential applications. See warranty for full details. Outdoor Coil Face Area 1 Sq. Ft. 8.0 No. Rows 3 Fins per inch 18 Circuits 6 Compressor Type Rotary Inverter Model ATF250D22UMT Oil Type VG74 Oil Charge FI. Oz. 23.6 Rated Current RLA 15.0 Outdoor Unit Width in (mm) 37.24 (946) Unit Height in (mm) 31.89 (810) Unit Depth in (mm) 16.14 (410) Net Weight lbs (kg) 139.8 (63.4) Airflow CFM 2,130 Sound Pressure dB(A) 60.5 Edition Date: 03/2018 Catalog No: 38MAR-30-3-04S8 SUBJECT TO CHANGE WITHOUT NOTICE Page 1 Replaces: 38 M A R-30-3.03 S B Performance High Wall Indoor Model 40MAQB30B--3 Indoor Model 619PEQ030BBMA Indoor Model DHMSHAQ3OXA3 Energy Star NO Cooling Rated Capacity Btu/h 30,000 Cooling Cap. Range Min - Max Btu/h 8000-30500 SEER 19.8 EER 11.5 Heating Rated Capacity (47°F) Btu/h 30,000 Heating Rated Capacity (17"F) Btu/h 18,500 Heating Maximum Capacity (17°F) Btu/h 18,500 Heating Maximum Capacity (5°F) Btu/h 16,380 Heating Cap. Range Min - Max Btu/h 9000-34000 HSPF 9.4 COP (47°F) WNW 2.60 COP (17°F) W/W 2.16 COP (5"F) W/W 2.20 Vertical Fan Coil Indoor Model FFMANP031T00 Energy Star NO Cooling Rated Capacity Btu/h 30,000 Cooling Cap. Range Min - Max Btu/h 8000-31,600 SEER 17.0 EER 11.5 Heating Rated Capacity (47°F) Btu/h 30,000 Heating Rated Capacity (17°F) Btu/h 21,400 Heating Maximum Capacity (17"F) Btu/h 21,300 Heating Maximum Capacity (5°F) Btu/h 21,300 Heating Cap. Range Min - Max Btu/h 9,000-31,800 HSPF 10.0 COP (47°F) W/W 3.50 COP (17°F) W/W 2.12 COP (5°F) W/W 1.96 Horizontal Fan Coil Indoor Model FPMBN*030T00 Energy Star NO Cooling Rated Capacity Btu/h 30,000 Cooling Cap. Range Min - Max Btu/h 8,000-30,600 SEER 15.0 EER 9.8 Heating Rated Capacity (47'F) Btu/h 30,000 Heating Rated Capacity (17°F) Btu/h 20,600 Heating Maximum Capacity (17T) Btu/h 20,200 Heating Maximum Capacity (5"F) Btu/h 19,200 Heating Cap. Range Min - Max Btu/h 9000-30,600 HSPF 9.6 COP (47°F) WAW 3.00 COP (17"F) W/W 2.19 COP (5'F) W/W 2.09 Copyright 2018 CAC/BDP • 7310 W. Morns St. Indianapolis. IN 46231 Edition Date: 03/2018 Catalog No: 38MAR-30-3-04S8 SUBJECT TO CHANGE WITHOUT NOTICE Page 2 Replaces: 38MAR-30-303SB • Construction View Outdoor Model: 38MAQB30R--3 Copyright 2018 CAC/BDP • 7310 W. Morris Si Indianapolis. IN 46231 .(E. ri)u Edition Date: 03/2018 3.38 it Catalog No: 38MAR-30-3-04SB SUBJECT TO CHANGE WITHOUT NOTICE Page 3 Replaces: 38MAR-30-3-03SB 8/5/2019 City of Tukwila Department of Community Development YAN DING PO BOX 1455 MONROE, WA 98272 RE: Permit No. M18-0152 BECU 12770 GATEWAY DR Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 9/21/2019. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or fmal inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 9/21/2019, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Kadace Nichols2 Permit Technician File No: M18-0152 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COPS - PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M18-0152 PROJECT NAME: BECU SITE ADDRESS: 12770 GATEWAY DR S X Original Plan Submittal Response to Correction Letter # Revision # DATE: 11/16/18 before Permit Issued after Permit Issued Revision # DEPARTMENTS: \\\1 ;iti.(1(1?:1ing Division Public Works At'( N/4 Fire Prevention Structural n PIanning Division Permit Coordittor to PRELIMINARY REVIEW: Not Applicable (no approval/review required) REVIEWER'S INITIALS: DATE: 11/20/18 Structural Review Required DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) Approved with Conditions Denied (ie: Zoning Issues) DUE DATE: 12/18/18 n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 PRECISE HEATING & COOLING, -IX }Tome Espanol Contact: Safety & Health Claims & Insurance Washington State Department of �J Labor & Industries Page 1 of 2 Fearch L&I A -Z. Index I -I eIp My Lel Workplace Rights Trades & Licensing PRECISE HEATING & COOLING LLC Owner or tradesperson Principals MOORE, LAMAR RALPH, PARTNER/MEMBER STRINGER, MICHAEL LEE, PARTNER/MEMBER (End: 04/24/2015) Doing business as PRECISE HEATING & COOLING LLC WA UBI No. 603 122 887 PO BOX 1455 MONROE, WA 98272 206-861-2525 SNOHOMISH County Business type Limited Liability Company Governing persons LAMAR MOORE MICHAEL L STRINGER; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. ..... ........................... Meets current requirements. License specialties HeatingNent/Air-Conditioning and Refrig (HVAC/R) License no. PRECIHC891 L9 Effective — expiration 06/29/2011— 06/29/2019 Bond Wesco Insurance Co Bond account no. 46WB043501 $6,000.00 Received by L&I Effective date 04/07/2014 04/20/2014 Expiration date Until Canceled Bond history Insurance Ohio Security Ins Co Policy no. BKS55371340 Received by L&I 11/08/2018 $1,000,000.00 Effective date 11/29/2016 Expiration date Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=603122887&LIC=PRECIHC891 L9&SAW= 12/4/2018 PRECISE HEATING & COOLING LLC Page 2 of 2 11/29/2019 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts ............. No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations Infraction no. EJACH00852 Issue date 08/06/2015 Violation city MONROE Type of violation ELECTRICAL CITATION Description Offering, bidding, advertising, or performing electrical installations, alterations or maintenance outside the scope of the firm's specialty electrical contractors license. (Installing low voltage conductors at a commercial site) Satisfied .............. RCW/WAC 19.28.041 RCW Violation amount $500.00 Workers' comp Do you know if the business has empioyees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID Account is current. 217,035-00 Doing business as PRECISE HEATING & COOLING LLC Estimated workers reported Quarter 3 of Year 2018 "4 to 6 Workers" L&I account contact T4 / CASSANDRA SMITH (360)902-5632 - Email: SMCA235@lni.wa.gov Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid ........... No debarments have been issued against this contractor. Workplace safety and health No inspections during the previous 6 year period. e? Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=603122887&LIC=PRECIHC891 L9&SAW= 12/4/2018