Permit M18-0161 - BOEING #9-98 - COMPRESSED AIR PIPING, DUCTWORK, VAV UNITS, ETC
BOEING #9-98 9725 E MARGINAL WAY S BLDG 9-098 M18-0161 Parcel No: Address: r � City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 0003400018 Permit Number: M18-0161 9725 E MARGINAL WAY S BLDG 9-098 Issue Date: 12/11/2018 Permit Expires On: 6/9/2019 Project Name: BOEING #9-98 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: BOEING COMPANY THE PO BOX 3707 M/C 20-59 PROPERTY TAX DEPT, SEATTLE, WA, 98124 HEATHER DARST 3051 E VALLEY RD , RENTON, WA, 98057 APOLLO MECHANICAL CONTRACTORS 1133 W COLUMBIA DR, KENNEWICK, WA, 99336 APOLLMC864JQ Phone: (206) 305-0707 Phone: (509) 586-1104 Expiration Date: 4/18/2020 DESCRIPTION OF WORK: FURNISH AND INSTALL COMPRESSED AIR PIPING AND CONNECT TO EXISTING PIPING FURNISH AND INSTALL NEW DUCTWORK, 4V A V TERMINAL UNITS AND GRILLS TAB, INSULATION AND CONTROLS FOR ABOVE SCOPE. Valuation of Work: $50,000.00 Type of Work: REPLACEMENT Fuel type: ELECT Fees Collected: $889.67 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: TUKWILA Sewer District: VALLEY VIEW,TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 OA- _Permit Center Authorized Signature: Date: 1 1 g I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: 7/ Date: / //i / g' Print Name: (C. r This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0701 ROUGH -IN MECHANICAL r 1 CITY OF TUKh, ; A Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. M l Project No. o ( Date Application Accepted: Date Application Expires: l-6)-�1'!� (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION King Co Assessor's Tax No.: 5624201032 Site Address: 9725 E Marginal Way S, Seattle 98108 Suite Number: 9-98 Floor: NA Tenant Name: The Boeing Co PROPERTY OWNER Name: Heather Darst Name: The Boeing Co City: Renton State: WA zip: 98057 Address: 9725 E Marginal Way S Email: heather.darst@apollomech.com City: Seattle State: WA 98 Zip: 98108 CONTACT PERSON — person receiving all project communication Name: Heather Darst Address: 3051 E Valley Rd City: Renton State: WA zip: 98057 Phone: (206) 305-0707 Fax: Email: heather.darst@apollomech.com New Tenant: ❑ Yes ..No MECHANICAL CONTRACTOR INFORMATION Company Name: Apollo Mechanical Address: 3051 E Valley Rd City: Renton State: WA Zip: 98057 Phone:(253) 872-5151 Fax: Contr Reg No.: APOLLMC864JQ Exp Date: 04/18/2020 Tukwila Business License No.: BUS -0995051 Valuation of project (contractor's bid. price): $ 50,000 Describe the scope of work in detail: Furnish and install compressed air piping and connect to existing piping Furnish and install new ductwork, 4 VAV terminal units and grills TAB, Insulation and Controls for above scope Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement Fuel Type: Electric E Gas ❑ Other: H:\Applications\Forms-Applications On Line\2016 Applications\Mechanical Permit Application Revised 1-4-16.docx Revised: January 2016 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Residential, Nighttime Furnace >100k btu Industrial Floor furnace 55 dB(A) Suspended/wall/floor mounted heater 57 dB(A) Appliance vent Commercial Repair or addition to heat/refrig/cooling system 1 Air handling unit 65 dB(A) <10,000 cfm 4 Unit Type Qty Air handling unit Residential, Nighttime >10,000 cfm Industrial Evaporator cooler 55 dB(A) Ventilation fan connected to single duct 57 dB(A) Ventilation system Commercial Hood and duct 47 dB(A) Incinerator — domestic 65 dB(A) Incinerator — comm/industrial 60 dB(A) Unit Type Qty Fire damper Residential, Nighttime Diffuser Industrial Thermostat 55 dB(A) Wood/gas stove 57 dB(A) Emergency generator Commercial Other mechanical equipment 47 dB(A) 60 dB(A) 65 dB(A) Boiler/Compressor QtY 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-1 OPM, Monday through Friday. and 8AM-10PM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: • Warning devices; • Construction and property maintenance during the daytime hours (lam -1 Opm); • Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ZED AGENT: Signature: ��``"'�rI� ��j� Date: 11/26/2018 Print Name: Heather Darst Day Telephone: (206) 305-0707 Mailing Address: 3051 E Valley Rd Renton WA 98057 City H:Wpplications\Forms-Applications On Line V2016 Applications\Mechanical Permit Application Revised 1-4-16.docx Revised: January 2016 bh State Zip Page 2 of 2 DESCRIPTIONS . ACCOUNT QUANTITY I PermitTRAK PAID $718.58 M18-0161 Address: 9725 E MARGINAL WAY 5 BLDG 9-098 Apn: 0003400018 $718.58 Credit Card Fee $20.93 Credit Card Fee R000.369.908.00.00 0.00 $20.93 MECHANICAL $664.43 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $631.28 TECHNOLOGY FEE $33.22 TECHNOLOGY FEE R000.322.900.04.00 0.00 $33.22 TOTAL FEES PAID BY RECEIPT: R16019 $718.58 Date Paid: Tuesday, December 11, 2018 Paid By: JARROD DIAMOND Pay Method: CREDIT CARD 038039 Printed: Tuesday, December 11, 2018 9:24 AM 1 of 1 SYSTEMS Page 1 of 2 CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA 0017340000802374464500 Date: 12/11/2018 09:23:39 AM CREDIT CARD SALE MASTERCARD CARD NUMBER: **********7904 K TRAN AMOUNT: $718.58 APPROVAL CD: 038039 RECORD #: 000 CLERK ID: Bill X {CARDHOLDER'S SIGNATURE} I AGREE TO PAY THE ABOVE TOTAL AMOUNT ACCORDING TO THE CARD ISSUER AGREEMENT (MERCHANT AGREEMENT IF CREDIT VOUCHER) Thank you! Merchant Copy https://classic.convergepay. com/VirtualMerchant/transaction.do?dispatchMethod=printTr... 12/1 1 /2018 1 DESCRIPTIONS ACCOUNT QUANTITY PAID PermitTRAK $171.09 M18-0161 Address: 9725 E MARGINAL WAY BLDG 9-098 Apn: 0003400018 $171.09 Credit Card Fee $4.98 Credit Card Fee R000.369.908.00.00 0.00 $4.98 MECHANICAL $166.11 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R15935 i R000.322.102.00.00 0.00 $166.11 $171.09 Date Paid: Thursday, November 29, 2018 Paid By: HEATHER DARST Pay Method: CREDIT CARD 05654D Printed: Thursday, November 29, 2018 2:29 PM 1 of 1 SYSTEMS Page 2 of 2 CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA Date: 11/29/2018 02:28:54 PM CREDIT CARD SALE VISA CARD NUMBER: **********6939 K TRAN AMOUNT: $171.09 APPROVAL CD: 05654D RECORD #: 000 CLERK ID: Bill Thank you! Customer Copy https://classic. convergepay.com/VirtualMerchant/transaction.do?dispatchMethod=printTr... 11 /29/2018 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 X18-���1 Project: Ne.'- Type of Inspection: rvli£ci- C1 9 -t._ Fr -L- Address: 72S i 114 r;6.j — Dae Called: Special Instructions: 6 76 ate Wanted: 3 cy '/ / a.m. p.m. Requester: Phone No: OnApproved per applicable codes. LJ Corrections required prior to approval. COMMENTS: '4 ►:c l (r -t- IIPR.d✓ 1) Inspector: Date: 3 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Project: IDOedw- .1 T of In section: IA . al Date C• Il^•: Address: 5 17zs- I, Otrfiteirt Special Instructions: #--9 _ 'v �/�ylq Date Wanted:31 I1 a.m. �J le(p.m. Requester: C9 (et -Q.4245) Phone No: zo&— 9zo- 6Fyz Approved per applicable codes. Corrections required prior to approval. COMMENTS: -C4 T 1 626.Evt.0 l C.Gt , Nr -Ox- iv\51A-v-t_j-Dtkr-i- -1€3-t ?‘) psz Inspector: Date: 41 1 cr REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 7-0---1O. INSPECTION RECORD Retain a copy with permit INSP PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 MV -o66/ Project: T of Ins ect`on: ro �a� n Approved per applicable codes. Corrections required prior to approval. COMMENTS: /476,-ItA14,1‘ "--1-117:41P 6r, L -Lc -- 0 `rb I, IJoetc0 Nio c kr. e& l uede---14 - Inspector: P Date zo1s REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. it...9e .01 4eeuc4 7pAddress 7 -4fl, /kat Date C •' ed: ecial Instructions: Date Wanted: t"y g.' 2--7-140/, P.m. Requester: 67 Phone No. Approved per applicable codes. Corrections required prior to approval. COMMENTS: /476,-ItA14,1‘ "--1-117:41P 6r, L -Lc -- 0 `rb I, IJoetc0 Nio c kr. e& l uede---14 - Inspector: P Date zo1s REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy permit ermit INS'' ': NO. ERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Project. ZicatriyA Type o pection: olt C -- Address:D �z r ,AA, aivi ate Ca led: s in, Instructions: - 7X- 4W2 C p Date Wanted: 2.. • . lc\ a.m. p.m. Requester: ��v Phone No: 0 Approved per applicable codes. a Corrections required prior to approval. COMMENTS: Chlf-°<C1 OV‘S Inspector: Date: (...B CCS REINSPECTION FEE REQUIRED. Prior to next inspeEtion, f- - must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. APOLLO MECHANICAL CONTRAORS home Espanol Contact Safety & Health Claims & Insurance 0 Washington State Department of Labor & Industries 0 €Search L&I Page 1 of 3 A-"ZIndex Help MyL&I Workplace Rights Trades & Licensing APOLLO MECHANICAL CONTRACTORS Owner or tradesperson Principals RATCHFORD, BRUCE W, PRESIDENT BRISCOE, DAN, VICE PRESIDENT RATCHFORD, RYAN B, VICE PRESIDENT HAISCH, ANGIE, SECRETARY HAISCH, ANGIE, TREASURER HIGHTOWER, BOB, VICE PRESIDENT (End: 04/06/2018) Doing business as APOLLO MECHANICAL CONTRACTORS WA UBI No. 600 443 607 Parent company APOLLO SHEET METAL INC 1133 W. COLUMBIA DRIVE KENNEWICK, WA 99336 509.586-1104 BENTON County Business type Corporation Governing persons BRUCE WAYNE RATCHFORD BOB HIGHTOWER; DAN BRISCOE; ANGIE HAISCH; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. APOLLMC864JQ Effective — expiration 04/18/2014— 04/18/2020 Bond Western Surety Co Bond account no. 58714750 Active. Meets current requirements. $12,000.00 Received by L&I Effective date 04/18/2014 04/08/2014 Expiration date Until Canceled Insurance ......... . ............ Cincinnati Ins Co $1,000,000.00 Policy no. EPP0044685 Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=600443607&LIC=APOLLMC864JQ&SAW= 12/11/2018 APOLLO MECHANICAL CONT\CTORS Received by L&I i Effective date 09/18/2018 09/30/2013 Expiration date 09/30/2019 Savings ................... No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID 442,528-00 ............................... Doing business as APOLLO SHEET METAL INC Estimated workers reported Quarter 3 of Year 2018 "Greater than 100 Workers" L&I account contact TO / JULIE SUR (360)902-4715 - Email: SURJ235@Ini.wa.gov Account is current. Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes ...................................................... No strikes have been issued against this contractor. Contractors not allowed to bid ..................... No debarments have been issued against this contractor. Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 06/22/2017 Inspection no. 317944907 Location 2001 Saint St. Richland, WA 99354 Inspection results date 12/04/2015 Inspection no. 317938581 Location 4891 W. 27th Avenue Kennewick, WA 99336 Inspection results date 08/17/2015 Inspection no. 317937422 Location 3715 US State Hwy 97A Wenatchee, WA 98801 Inspection results date No violations No violations No violations Page 2 of 3 Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=600443607&LIC=APOLLMC864JQ&SAW= 12/11/2018 City of wila Business License License #: BUS -0995010 Issued Date: 01/01/2018 Expiration Date: 12/31/2018 Bus Lic-Outside Contractor APOLLO SHEET METAL INC 1207 W COLUMBIA DR KENNEWICK, WA 99336 UBI: 600443607 Nature of Business: MECHANICAL CONTRACTOR Business Name: APOLLO SHEET METAL INC Business Address: 1207 W COLUMBIA DR, KENNEWICK, WA 99336 FINANCE DIRECTOR 7C LICENSEE AGREES TO COMPLY WITH ALL THE REQUIREMENTS OF CITY ORDINANCES AND STATE LAWS APPLICABLE TO THE BUSINESS ACTIVITY LICENSED HEREUNDER. This license is to be displayed conspicuously at the location of business and is not transferrable or assignable. Please note the following guidelines In the operation of your business: It is necessary to contact the Finance Office at 206-431-3680 in the event your business: Moyes within the- city limits of Tukwila . Moves outside the city limits . Ceases operation • Changes ownership • Changes use or type of operation . Will be having a special event (such as a tent sale, parking lot sale or any other event) outside its routine operation. 2. Additional licenses are required if your business has live music/entertainment, tow trucks, amusement devices, solicitors/peddlers, or adult entertainment. 3. Any retail sales tax generated in Tukwila needs, to be reported to the Washington State Department of Revenue, under sales tax code # 1729. 4. Tukwila business license renewals are mailed to all licensed businesses in December and payable without penalty until January 31. Department of Labor and Industries PO Box 44450 Olympia, WA 98504-4450 .170 APOLLO MECHANICAL CONTRACTORS 1133 W. COLUMBIA DRIVE KENNEWICK WA 99336 APOLLO MECHANICAL CONTRACTORS. Reg: CC APOLLMC864JQ Ul3I: 600-443-607 Registered as provided by Law as: Construction Contractor (CCO1) - GENERAL Effective Date: 4/18/2014 Expiration Date: 4/18/2020 Plan review approval is subject to errors omissions Approval of construction documents does tot authorize the violation of any adopted code or ordinance Recel.t of approved Field Copy and cond ti 1 n. : cknowiedged VICINITY MAP FROM DOWNTOWN SEATTLE 7-127 laic COUNT' AIRPORT OFACE CENTER (FWa 900 99 EXO 157 99 EAST MARGINAL WAY CORPORATE PARK FROM SEATTLE—TACOMA AIRPORT DEVELOPMENTAL CENTER FROM KENT & AUBURN 900 NO SCALE THE BOEING COMPANY 9-98 11 N7 LAB #W5787963 BOEING DEVELOPMENTAL CENTER 9725 E. MARGINAL WAY S. TUKWILA, WASHINGTON 98108 SEPARATE PERMIT REQUIRED FOR: p Mechanical Or Electrical Q Plumbing I ' Gas Piping City of Tukwila BUILDING DIVISION AREA MAP BUILDING ADDRESS: 9725 EAST MARGINAL WAY SOUTH TUKWILA, WASHINGTON 98108 No changes shall be made to the scope of work without prior approval of the Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may Include additional plan revel NO SCALE 9-98 BUILDING LOCATION GENERAL NOTES CONSTRUCTION SET OF DOCUMENTS, REVIEWED AND STAMPED BY CITY OF TUKWILA MUST BE ON SITE DURING CONSTRUCTION. DO NOT PROCEED WITH CONSTRUCTION WITHOUT ABOVE MENTIONED SET OF DOCUMENTS. 1. VERIFY ALL DIMENSIONS AND CONNECTIONS BEFORE ANY WORK. 2. NOTIFY FACILITY ENGINEERS SHOULD EXISTING CONDITIONS REQUIRE DESIGN REVISIONS. 3. COORDINATE WORK WITH OTHER CRAFTS. 4. RETURN THIS SAME SET TO MARTY R. PROBST BUILDING 9-51.2 COLUMN M/1, AFTER COMPLETION OF THIS CONSTRUCTION. PROJECT CHECKLIST CHECK BOX ® THESE DRAWINGS CONFORM TO THE I.B.C., I.F.C., I.M.C., U.P.C., N.E.C. AND THE WAC 51-20 AS ADOPTED OR AMENDED BY LOCAL ORDINANCES AND COMPLIANCE WITH CITY OF TUKWILA, WASHINGTON ZONING. ROOMS LABELED PER OCCUPANCY PER I.B.C. TABLE 1004.1.2. BUILDING FLOOR NUMBER ON PRINT FOR AREA OF CONSTRUCTION. NUMBER OF PRINTS REQUIRED FOR PERMIT PACKAGE: O 1. TENANT IMPROVEMENT (STRUCTURAL): ❑ 5 SETS OF ARCHITECTURAL DRAWINGS ❑ 5 SETS OF STRUCTURAL DRAWINGS ❑ 5 SETS OF STANDARD DETAILS O 5 SETS OF ENGINEERING CALCULATIONS ❑ 5 SETS OF ENERGY CALCULATIONS ❑ 5 SETS OF CONSTRUCTION SPECIFICATIONS O 2. TENANT IMPROVEMENT (NON—STRUCTURAL): ❑ 4 SETS OF ARCHITECTURAL DRAWINGS ❑ 4 SETS OF STANDARD DETAILS ❑ 4 SETS OF ENERGY CALCULATIONS ❑ 4 SETS OF CONSTRUCTION SPECIFICATIONS ❑ 3. MECHANICAL, 4 COMPLETE SETS. ❑ 4. FIRE PROTECTION/SPRINKLERS, 3 COMPLETE SETS. O BRIEF PROJECT NARRATIVE: MINOR RECONFIGURATION OF EXISTING SECURE SPACE FOR NEW LAB. INCLUDES CONSTRUCTION OF NEW NON—BEARING WALLS AND ADDITION OF TWO ACOUSTIC DOORS. MINOR ELECTRICAL AND MECHANICAL WORK TO ACCOMMODATE NEW CONFIGURATION AND LAB EQUIPMENT. REVIEWED FOR CODE COMPLIANCE APPROVED DEC 0 5 2018 (/O City of Tukwilf BUILDING DIVISION CODE SUMMARY LAND USE CODE BUILDING CODES OCCUPANCY GROUP CONSTRUCTION TYPE FLOOR AREAS: BUILDING FOOTPRINT BUILDING GROSS FIRST FLOOR SECOND FLOOR PENTHOUSE BUILDING HEIGHT STORIES OCCUPANT LOAD: HANDICAPPED REQUIREMENTS FIRE PROTECTION SEISMIC ZONE DESIGN LOADS: ROOF — SNOW/UVE FLOOR — OFFICE (UVE) FLOOR — DEAD FLOOR — MECHANICAL & STORAGE FLOOR — STAIRS AND CORRIDORS WIND LOADING FIRE EXTINGUISHERS: (I) CITY OF TUKWILA, WASHINGTON 2015 INTERNATIONAL BUILDING CODE (IBC) 2015 INTERNATIONAL FIRE CODE (IFC) 2015 INTERNATIONAL MECHANICAL CODE (IMC) 2015 NATIONAL ELECTRICAL CODE (NEC) 2015 UNIFORM PLUMBING CODE (UPC) 2015 STATE OF WASHINGTON ENERGY CODE STATE OF WASHINGTON BARRIER FREE CODE WITH CITY OF TUKWILA, WA. AMENDMENTS GROUP B, OFFICE TYPE II -0, NON—COMBUSTABLE 67,351 145,382 67,351 67,351 10,680 44 FT. 2 NO CHANGES BARRIER FREE FULLY AUTOMATIC, F/S CLASS 1 SPRINKLERS THROUGHOUT DESIGN CATEGORY "D" 25 PSF 50 PSF 20 PSF (PARTFTION) 125 PSF 100 PSF 80 MPH, EXPOSURE C TYPE: AMEREX MODEL 461, RATED 3A:40B:C, 6 LB CAPACITY. MAXIMUM retE TRAVEL DISTANCE TO EXTINGUISHER = MAXLii33 OFTUKWILA ivVpLETI5FENGETUI,SHER IM=UM11FL ,25O0ORSFAREACIT CEIVE D ISSUE FOR CONSTRUCTION 10.02.18 9Y DATE SYM BEMs ON 9f AI'PROkD OME EXTRS: 9-98 REWORK OFFICE AREA 'A' 4180166-02 GLIM 12.14.98 B 9-98 RENOVATION ADDENDUM 1 Ji 140799-00 DDR GROUP D.REID 08.24.06 EXTRS 9-98 REWORK OFFICE AREA '8' J/180166-04 GMM 02.11.99 RECORD DRAWING DDR GROUP D.REID 07.23.07 ERRS: OC: RELOCATE ESI1MA11NG J/190083-00 CMM 08.11.99 11N7 W5787963 _c/ROLLUDA 10.02.18 ce;I_Arzw-ivAw ACCEPTABILITY 1110 DEOGN MD SPSPECIFICATION6 APOR DRAWN G.MILLER CHECKED 5090100 TITLE SHEET NUv292018 i-`ERt' T CENTER CITY OF TUKWILA BLANKET PERMIT NO. BPA17-009 BOEING *294 ML 01.18 2019 CURRENT REVISION W5787963 SYMBOL DATE 10.02.18 APPROVED BY DATE G.MILLER CHECKED 12.14.98 11N7 LAB BUILDING 9-98 GO JOB NO. W0707051 COMP N0. WNDT: 7/26/2007 5:06:36 PW 13 12 11 10 MATCH UNE -FOR "ON TIN I SEE SHEET 1A11 6'-6" 20'-0" 20'-0" 15'-8" TYPO 1A11 A201 12 1A121A507 MATCH UNE -FOR CONTIN 1Al2 A62 SEE SHEET 1A13 12'-5" 14'-7" ®O 4'-4" 1 20'-0" 0 CO ® © O 20'-0" 4'-4" 15'-8" 20'-0" 20'-0" 6'-6" O- STORAGE 112 L6 1 7'-9 L CORRIDOR 112T5 I /2" 3'-3" '-9.7717--3( 1/4" ® O o-211 11'-8 1/4" a1 FEC .0 - STORAGE 1 11L6 1 w' N MAIL OPEN OFFICE 111L8 I 15'-9" 3'-10 1/4" 3 -7 1/4" • 8'-1" O RECYCLE 1 11L3 I 2'-0" CORRIDOR I 11T5 I 4'-8 1 /4" STORAGE 111N4 FILES 111N3 1 (11P41) SMALL OFFICE 11P4 1 2P4) SMALL OFFICE L 12P4 11'-0" 12-4 3/4 2 -6 1/2" 1 -10 1/4" 1 in 6'-2" `n I SMALL OFFICE 111N2 I (11N2) C 9'-6 3/4" 12'-5" o 2 1Al2 A201 (11R9} % Pf FIRST FLOOR PLAN SCALE: 1/8"= 1'-0" N ll- im REVIEWED FOR CODE COMPLIANCE /4�ROVED 1 DEC 0 5 2018 O LEGEND GENERAL NOTES 1. SECURED SCIF AREA SHOWN NO CONSTRUCTION U.N.O. I\\\\\\ V 2. SEE SHEET A200 FOR WALL TYPES THUS: 3. SEE SHEET A352 FOR RECITES SHOWN THUS: 4. INFILL CONCRETE FLOOR AS REQUIRED WERE REMOVED FOR INSTALLATION OF MECHANICAL AND ELECTRICAL EQUIPMENT. O REFERENCE DRAWINGS REMOVAL NOTES REMOVE EXISTING DEMOUNTABLE WALL, INCLUDING BRACING. PATCH AND REPAIR SLAB/FINISHES AS REQUIRED BY REMOVAL REMOVE EXISTING DOOR, FRAME AND HARDWARE. • REMOVE PORTION OF EXISTING WALL FOR NEW 4'-0" X 7'-0" DOOR AND FRAME. ® REMOVE EXISTING CARPET AND RUBBER BASE AT AREA SHOWN HATCHED. PATCH AND REPAIR CONCRETE SLAB AS REQUIRED BY REMOVAL. PATCH AND REPAIR WALLS AS REQUIRED BY BASE REMOVAL. REMOVE ALL SYSTEMS FURNITURE AT PROJECT AREA AND DISPOSE OF. City of Tukwila REMOVAL ISSUE FOR CONSTRUCTION 10.02.18 RECEIVED CITY OF TUGKWILA NOV 2 9 2018 PERElGOT CENTE=R KEY PLAN SCALE NONE 8' 4' 0 4' 8' 16' SCALE: 1/8"=1'-0" APPROVED DATE SYM DATE A 9-98 RENOVATION Jj 140799-00 01R GROUP D.REID 08.15.06 8 9-98 RENOVATION ADDENDUM 1 Jj 140799-00 DLR GROUP D.REID 08.24.06 RECORD DRAWING J/ 140799-00 DLR GROUP D.REID 07.23.07 g)LAF417E4rAf ACCEPTABILITY DLR GROUP S �I 6604 THIS DESIGN APPROVED CHECKED \\' �� SPECIFICATION 00QN IS APPROJED ��� APPROVED EY ' DEPT. DATE STATE OF WASHINGTON 07.25.06 07.25.06 HEC ED DENRE FIRST FLOOR PLAN - REMOVAL TRU 11N7 LAB BUILDING 9-98.1 CURRENT REVISION W5787963 SYMBOL DATE 10.02.18 1Al2R JOB N0 wa/o7nC1 COMP NO. PP 13 12 11 CD ®® ®7 ®® MATCH LINE -FOR CONTIN. SEE SHEET 1A11 6'-6" 20'-0" 20'-0" 15'-8" 4'-4" 20'-0" 20'-0" 4.-4" 15'-8" 20'-0" RECEIVE® MTV OF TUKWILI NOV 2 9 2018 PERM- CENTER CD 20'-0" 6'-6" 1 1Al2 A61 (®VENT 1 11L12 1 13'-4 1/ 1A11 A201 1A1,21907 MATCH UNE -FOR CONTIN. SEE SHEET 1A13 OPEN OFFICE 1 11L8 1 14'-7" 1Al2 A510 CORRIDOR 1 12T5 1 6'-11 1/4" 7'-9 /2" 3'-3" -6 1/4" Aint" 11'-3 1/4" FEC LEGEND GENERAL NOTES 1. SECURED SCIF AREA SHOWN NO CONSTRUCTION U.N.O. 2. SEE SHEET A200 FOR WALL TYPES THUS: 3. SEE SHEET A352 FOR ELITES SHOWN THUS: 4. INFILL CONCRETE FLOOR AS REQUIRED WERE REMOVED FOR INSTALLATION OF MECHANICAL AND ELECTRICAL EQUIPMENT. 11'-8 1/4" -10 1/4" 1M 2A 1 alb O STORAGE STORAGE RECYCLE CONFERENC A505 SMALL OFFICE 130 SF OFFICE 184 SF SMALL OFFICE 13'-11 3/4" 125 SF CORRID6R 11N4) 11IN3 SMALL OFFICE STORAGE REFERENCE DRAWINGS CONSTRUCTION NOTES CONSTRUCT NEW ICD 705 SECURE WALL FROM FLOOR SLAB TO HARD CEILING ABOVE SUSPENDED CEILING. 3 5/8° X 16 GA. STEEL STUDS AT 16" O.C. (1) LAYER 5/8" GWB AT NON -SECURE SIDE (2) LAYERS 5/8" GWB AT SECURE SIDE STAGGER JOINTS SO THEY DO NOT ALIGN INSTALL RADIO FREQUENCY PROTECTING FOIL BETWEEN SECURE SIDE LAYERS OF GWB 3 1/2" ROXUL ACOUSTIC INSULATION PROVIDE ACOUSTIC SEALANT AT TOP AND BOTTOM OF WALL WHERE MEETING FLOOR/CEILING. BED BOTTOM TRACK OF WALL IN A CONTINUOUS BED OF ACOUSTICAL SEALANT. PREP AND PAINT WALL, BOTH SIDES. PPG 'DELICATE WHITE' (PPG1001-1). SEE DETAIL B/A515. PROVIDE AND INSTALL STC 45 DOOR AND FRAME. KREIGER SPECIALTY PRODUCTS, NC3-17C-8951 HINGES BY DOOR MANUFACTURER CLOSER YALE 4400 X 689 LOCKSET SARGENT & GREENLEAF 28906 X TYPE II X 2890-523 (BY BOEING). LOCK TRIM SARGENT & GREENLEAF 2890-632 SWEEP BY DOOR MANUFACTURER SEALS BY DOOR MANUFACTURER WALL STOP TRIMCO 1270 WX X 630 GROUT FRAMES SOLID - USG 'STRUCT-0-UTE' SMALL OFFICE 9'-6 3/4" D>> CLEAN AND PREP CONCRETE SLAB AND SEAL AT AREA SHOWN HATCHED. SMALL OF 4 1 11P9 1 4'-5 1/2 SMALL OFFICE 11P4 1 ^1 SMALL OFFICE I I� 12R9 SMALL OFFICE 1 13R9 1 2P4) SMALL OFFICE , OPEN EFRCE NVIR� CHAMBE 1 12R9 I m 11.-0" 12-4 3/4 2 -6 1/2" 9'-1 3/4" REVIEWED FO CODE COMPLIA 1_1c1PROVED DEC 0 5 2018 4 • VAC_ 1 11R9 1 1Al2 A370 City of Tukwila BUNG DIVISI �J BRIGHTON - HARD ROCK SEALER ROPPE 'BROWN -BLACK' 1193 4 1/2" COVE BASE G&W COMMERCIAL FLOORING 253.479.1760 WWW.GWCFLOOR.COM PREP AND PAINT EXISTING WALL FROM FLOOR TO CEIUNG. ALL WALLS AT VESTIBULE. PPG 'DEUCATE WHITE' (PPG1001-1). PATCH AND REPAIR EXISTING CARPET WHERE WALL HAS BEEN PREVIOUSLY REMOVED FOR NEW/WIDENED DOOR OPENING. PROVIDE AND INSTALL 25 UNIT CELL PHONE LOCKER AT EXISTING COUNTER. GLOBAL 24 DOOR KEYED LOCK, BLACK 11T9A493332BK co FIRST FLOOR PLAN Q SCALE: 1/8"= 1'-0" 1Al2 7 ISSUE FOR CONSTRUCTION 10.02.18 CONSTRUC NEW ICD 705 SECURE WALL "OM FLOO' SLAB TO HARD CEILING ABOVE SUSPENDED CEIUNG. 3 5/8" X 16 GA. STEEL STUDS AT 16" 0.C. 1 LAYER 5/8" TYPE 'X' GWB AT NON -SECURE SIDE. LAYERS 5/8" TYPE X GWB AT SECURE SIDE. STAGGER JOINTS SO THEY DO NOT ALIGN. INSTALL RADIO FREQUENCY PROTECTING FOIL BETWEEN SECURE SIDE LAYERS OF WALL BOARD. 3 1/2" ROXUL ACOUSTIC INSULATION. PROVIDE ACOUSTIC SEALANT AT TOP AND BOTTOM OF WALL WHERE MEETING FLOOR/CEILING. BED BOTTOM TRACK OF WALL IN A CONTINUOUS BED OF ACOUSTICAL SEALANT. PREP AND PAINT WALL, BOTH SIDES. PPG 'DEUCATE WHITE' (PPG1001-1). SEE DETAIL B/A515. ADD (1) LAYER 5/8" TYPE 'X' GWB AT CONF. RM.SIDE. MAKE FLUSH W/NEW WALL CONSTRUCTION. CONSTRUCT NEW ICD 705 SECURE WALL FROM FLOOR SLAB TO HARD CEILING ABOVE SUSPENDED CEILING. 3 5/8" X 16 GA STEEL STUDS AT 16" O.C. (2) LAYERS 5/8" TYPE 'X' GWB, EACH SIDE. PROVIDE ACOUSTIC SEALANT AT TOP AND BOTTOM OF WALL WHERE MEETING FLOOR/CEILING. BED BOTTOM TRACK OF WALL IN A CONTINUOUS BED OF ACOUSTICAL SEALANT. PREP AND PAINT WALL, BOTH SIDES. PPG 'DEUCATE WHITE' (PPG1001-1). SEE DETAIL C/A515. 1A10 KEY PLAN SCALE NONE 4' 0 4' 8' 16' SCALE: 1/8"=1'-0" A 8 9-98 RENOVATION J/ 140799-00 9-98 RENOVATION ADDENDUM 1 4 140799-00 BY DLR GROUP DLR GROUP APPROVED DUE SEM BENSON BY APPROVED DATE 0.900 D.REID 08.15.06 08.24.06 - RECORD DRAWING 4 140799-00 DLR GROUP D.R00 07.23.07 g;LATAIE7AW ACCEPTABIUTY 1185 DESIGN MIO/0R SPECNICAT1ON IS APPROVED APPROVED BY DEPT. DATE STATE OF WASHINGTON DRAWN DLR GROUP CHECKED D. REID CHECKED APPROVED LAME 07.25.06 07.25.06 RUMBLE FIRST FLOOR PLAN CURRENT REVISION W5787963 SYMBOL are 10.02.18 TME 11N7 LAB BUILDING 9-98.1 1Al2 JOB N0. COMP N0. 814C: 12/09/08 14:50 MATCH UNE -FOR CON SEE SHEET 1A281 TT I. 'Niuini :WC% 0 A282 A509 swarm 5 10 0® 6'-8 3/4 IMINITIrraw 0 IISMEM �■, 1111171111111 1 6'-0' 6'-0' Io ■0 1 ■ 11 1 MATCH UNE -FOR CONTIN__- SEE SHEET 1A283 1 1 1 II s I� COt2RRIIDOR 3'-2 3/4 0 ���iiii�il�—�ii��i II TYP. 0 I 1 82 A507 0 0 n j CORRI '1R 0 TT GEO 1E 5 T. EMI 0 0 0 0 0 0 hhIi!IIi 11R9 3' -6 1111111 1111. 1 � M 111111 1 I MN ■■9 o ■ OPEN I 1111111 1■■IMO B-1111 i■■■I ELIMME EN -!!!!O 11111.1111111 1.1 11i1■i__ IIT R 1■■■I�Iiz 1_1 1 1111 1 IBM .. ingliFifiliblinallilia ,Irk I Mill C‘TIIVIEW 0 NM mil (8'-6') 10 -0 CD 10 1A2821510 FIRST FLOOR REFLECTED CEILING PLAN SCALE: 1/8'= 1'-0" O REVIEWED FOR M CODE COMPLIANCE APPROVED DEC 0 5 2018 City of Tukwila BUILDING DIVISIO STEEL BEAM LEGEND ® INDICATOR POWER POLE LOCATION TO BE COORDINATED WITH MANUFACTURER. I WALL CONSTRUCTION TO B.O. SLAB AND/OR B.O. STEEL BEAM. WALL CONSTRUCTION TO 4" ABOVE FINISHED CEIUNG, OR TO MATCH TOP OF EXISTING ADJACENT WALL CONSTRUCTION WHERE OCCURS. SUSPENDED GRID & PANEL SYSTEM. EXPOSED STRUCTURE ABOVE (PAINT). GYPSUM WALL BOARD (PAINTED). 0 UGHT FIXTURES. 0 UGHT FIXTURE (RECESSED CAN). WP AIR SUPPLY DIFFUSER. WORKING POINT ACCESS DOOR GENERAL NOTES 1. CEILING HEIGHT SHALL BE 8'-10' AFF. U.N.O. 2. SEE SHEET A501 FOR CEILING SEISMIC RESTRAINTS. 3. NOT ALL MECHANICAL DUCT WORK SHOWN AT OPEN TO STRUCTURE LOCATIONS. SEE MECH. FOR EXTENT OF WORK. REFERENCE DRAWINGS CONSTRUCTION NOTES MODIFY EXISTING GRID AS REQUIRED BY NEW WALL CONSTRUCTION. REMOVE AND REPLACE DAMAGED/STAINED ACOUSTIC TILES. ARMSTRONG FISSURED, MEDIUM TEXTURE, SQUARE LAY -IN, #755, WHITE. COORDINATE NEW MECHANICAL AND ELECTRICAL WORK AT CEILING. RECEIVED CITY OF TUKWILA NUV 2 9 2818 POIRET CENTER ( SUE FOR CONSTRUCTION 10.02.18 KEY PLAN SCALE: NONE 8' 4' 0 4' 8' 16' SCALE: 1/8•=1'-0• SYM 01 APPROVED DATE S14 A 9-98 RENOVATION J% 140799-00 DLR GROUP D.REID 08.15.06 R 9-98 RENOVATION ADDENDUM 1 J/ 140799-00 DLR GROUP D.REID 08.24.06 C 9-98 RENOVATION ASI 011 J/ 140799-00 DLR GROUP D.REID 11.01.06 012 .12 112 el_ArAmrAw° R.T< DE W,a.rN ACCEPTABILITY 1640 CESIGN AND/0R SPEGIFlCAIKIN IS APPROVED APPROVED BY DEPT. DATE 08ANT1 OLR GROUP CHECKED D. REID 07.25.06 07.25.06 FIRST FLOOR REFLECTED CEILING PLAN 608800 REVISION W5789763 SYMBOL DATE 10.02.18 2. 1187 LAB BUILDING 9-98.1 SKEET �� D. 1 A282 COMP N0. R� ICD ROOM CONSTRUCTION DETAILS THE CERTIFIED TEMPEST TECHNICAL AUTHORITY (CRA) HAS SPECIFIED THE FOLLOWING REQUIREMENTS: 1. FOIL UNED WALLBOARD. 2. FILTERS (EACH ROOM SEPARATELY FILTERED, ASSUMING 100DB ISOLATION). 3. IDENTIFY AND SEPARATE ALL RED/BLACK, TELEPHONE UNES, SIGNAL ONES, ALARM UNES ETC. 4. GROUND EVERYTHING, BUT TEMPEST DOOR NOT REQUIRED. 5. ENSURE ALL DUCTS/VENTS ARE UNE/BREAK WHATEVER WORKS BEST (NON—CONDUCTIVE). THIS DOCUMENT WILL DETAIL HOW TO INSTALL THE SHIELD AND HANDLE PENETRATIONS THROUGH THAT SHIELD. R SEEMS UNREASONABLE TO SHIELD THE ROOM BUT IGNORE HOLES/GAPS IN THE SHIELD WHICH WOULD OCCUR WHEN DRIWNG HOLES FOR POWER, HVAC, SPRINKLER, COMMUNICATIONS, AND OTHER PENETRATIONS. THEREFORE, WE WILL ATTEMPT TO IMPLEMENT A SOLUTION THAT IS RF TIGHT, BUT NOT REQUIRED TO MEET ANY SPECIFIC LEVELS OF ATTENUATION. THE GOAL IS TO HAVE 50 DB OF SHIELD ATTENUATION FROM 1 MHZ TO 10 GHZ. WE MUST ALSO MAINTAIN SECURITY INTEGRITY, BOTH PHYSICAL AND ACOUSTIC. THE FOLLOWING PENETRATIONS ARE KNOWN TO BE REQUIRED AND CREATE POSSIBLE SHIELDING LEAKS IF NOT INTENTIONALLY IMPLEMENTED TO PREVENT THIS: • AC POWER • ANALOG PHONE UNES • ETHERNET UNES • FIBER—OPTIC CABLING • OUTSIDE CABLE PATHWAY • HVAC CONTROLS • HVAC REFRIGERANT UNES • HVAC AIR DUCTS • ENTRY DOOR • SPRINKLER PIPE • DRYWALL SCREWS CONSTRUCTION DETAILS TO ENSURE SHIELD INTEGRITY AT PENETRATIONS: THE GENERAL SOLUTION FOR PENETRATIONS IS TO USE A GALVANIZED STEEL PLATE SCREWED TO THE INTERIOR STUDS AT EACH UTILITY PENETRATION POINT. THIS MUST BE INSTALLED DIRECTLY TO THE WALL STUDS PRIOR TO INTERIOR DRYWALL DETAILS FOLLOW BELOW. SEQUENCE OF INSTALL (ICD CLOSETS) 1. FRAME WALLS, DOOR FRAME, AND CEIUNG. 2. ADD HORIZONTAL BLOCKING FOR HVAC DUCT PASS THROUGHS. PHOTOGRAPH ALL FRAMING FROM INTERIOR. 3. INSTALL GALVANIZED STEEL PLATES ON INTERIOR STUDS OF ICD ROOMS AT UTILITY PENETRATION POINTS (TYPICALLY HIGH ON WALL). 4. INSTALL EXTERIOR DRYWALL AROUND ICD SPACE (LEAVE COMMON WALL BARE). 5. INSTALL ALTERS ON EXTERIOR WALL AND THROUGH THEIR PENETRATION PLATES. 6. INSTALL SLEEVES AND OTHER PENETRATIONS THROUGH STEEL PENETRATION PLATES. PHOTOGRAPH AU. OF THE INTERIOR. 7. INSULATE WALL PHOTOGRAPH. 8. INSTALL 1ST LAYER OF INTERIOR DRYWALL ACOUSTIC SEAL AROUND STEEL PENETRATION PLATES AND ANY EDGE DRYWALL EDGE GAPS. MARK STUDS. PHOTOGRAPH. 9. INSTALL HVAC WAVEGUIDES AND DUCT STUB FROM INSIDE WALL TO OUTSIDE. 10. INSTALL SHEET METAL CEIUNG AND FLOOR, THEN INSTALL FOIL AT WALLS. 11. CONNECT 1/2' BRASS ROOM GROUND STUD TO EARTH GROUND (STRUCTURAL STEEL). 12. INSTALL DOOR IF NOT INSTALLED. 13. CAP OFF PIPE SLEEVE PENETRATIONS HAVING NO PIPES, WITH METAL CAPS. 14. INSTALL POWER, UGHTS, HVAC, ALARMS, ETC IN 1CD ROOMS. 15. RUN BONDING BRAIDS FROM SINGLE POINT GROUND TO EACH STEEL PLATE AND DOOR FRAME. PHOTOGRAPH AU. INTERIOR. 16. RUN GROUNDING JUMPERS FROM STEEL PLATE TO METAL UTILITIES — HVAC UNES, SPRINKLER PIPE, AND ANYTHING ELSE REQUIRING GROUND. PHOTOGRAPH. CONSTRUCTION DETAILS: THE FOLLOWING ILLUSTRATIONS ARE INTENDED TO BE A POSSIBLE SOLUTION. MANY OTHER SOLUTIONS ARE POSSIBLE, SO TREAT THIS AS A GUIDE AND NOT A MANDATE EXCEPT FOR THE FOIL WHICH MUST NOT BE SUBSTITUTED ( PARTfl1BOO-48-125S). FOLLOW THIS PROCEDURE FOR SHIELD INSTALLATION GUIDANCE WITH THE FOLLOWING MODIFICATIONS: • INSTALL OVER DRYWALL AND DO NOT STAPLE. USE ADHESIVE TO ATTACH TO BUILDING SURFACES AND AVOID GETTING ADHESIVES BETWEEN OVERLAPPING FOIL CONTACT POINTS OR WHERE FOIL WILL BE TAPED. • OVERLAP ADJACENT SHEETS BY 6' AND WRAP AROUND AROUND ADJACENT SURFACES 8'. • SEAL WITH 4' ELECTRICALLY CONDUCTIVE PSA FOIL SEAMING TAPE CENTERING OVER SEAM UNE. • WRAP WALLS FIRST HORIZONTALLY COMPLETELY WRAPPING THE ROOM AND BENDING AROUND CORNERS. BE SURE TO OVERLAP CEIUNG AND FLOOR BY '8' AND ADJACENT SHEETS BY 6". • INTERIOR CONDUIT CLAMPS, ELECTRICAL BOXES, UGHTS, PIPE HANGERS, ETC. MUST ALWAYS SCREW INTO A STUD ( SO MARK STUD UNES ON FLOOR AND CEIUNG) OR USE AN ADHESNE TYPE CLAMP. CONSIDER INSTAWNG STRUT ON WALLS OR CEIUNG IF UTILITIES AND UGHTS CAN'T HANG ON A CEIUNG JOIST OR WALL STUD. SCREW MISSES AND SHIELD DAMAGE: SCREWS USED TO ATTACH DRYWALL TO STUDS OR ITEMS TO THE WALLS MUST BE CONDUCTNE AND PENETRATE A STUD. A SCREW THAT MISSES A STUD WILL NOT BE GROUNDED AND WILL ACT AS A PASSIVE RADIATOR THROUGH THE SHIELD WHICH IS MUCH WORSE THAN A SMALL HOLE. THIS MUST BE AVOIDED AND MITIGATED IF OCCURS. ANY SCREWS THAT MISS A STUD SHOULD BE REMOVED, PLACED BACK INTO THE SAME HOLE, AND REORIENTED TO ATTEMPT TO PENETRATE THE STUD. MINOR MANGUNG OF THE SHIELD FOIL DUE TO MULTIPLE SCREW INSERTIONS SHOULD NOT BE A MAJOR ISSUE. IF THE STUD CANNOT BE HR WITH THE SCREW, THEN DO THE FOLLOWING: • USE A PLUG CURER OR SIMILAR TOOL TO CUT A HOLE JN THE TOP DRYWALL LAYER ONLY TO EXPOSE THE FOIL — DO NOT CUT INTO THE FOIL USE A DEPTH CONTROL DEVICE ON THE CUTTER IF POSSIBLE HOLE DIAMETER TO BE APROX. DOUBLE THAT OF THE SCREW DIAMETER, OR WHATEVER IS NEEDED TO EXPOSE ENOUGH FRESH FOIL • CLEAN AND FLATTEN THE REMNANTS OF THE FOIL SURFACE. • FIND A GALVANIZED NAIL WITH A HEAD DIAMETER NEAR THAT OF THE PLUG HOLE DIAMETER (BOX OR ROOFING NAIL). CUT THE NAIL SHANK LENGTH TO 1/2". IF A LARGE HOLE WAS CUT, USE FOIL SEAMING TAPE INSTEAD OF A NAIL • SQUIRT RF CAULK INTO THE SCREW HOLE AND APPLY TO UNDERSIDE OF NAIL HEAD. • FIRMLY PUSH THE NAIL INTO SCREW HOLE UNTIL THE HEAD IS TOUCHING THE FOIL • AFTER CAULK FIRMS UP, FILL THE PLUG HOLE WITH DRYWALL MUD. IF THE SHIELD GETS PUNCTURED OR SLR BEFORE R IS COVERED WITH DRYWALL, TAPE OVER HOLES OR CUTS WITH 4' CONDUCTIVE PSA SEAMING TAPE. BE SURE FOIL SURFACE IS CLEAN AND FIRMLY ROLL THE TAPE TO ADHERE R TO THE FOIL PARTS UST. THE FOLLOWING MATERIALS SHOULD MEET THE REQUIREMENTS FOR THIS DESIGN. OTHER MATERIALS AND METHODS MAY BE SUBSTITUTED IF THEY MEET BOTH THE RF AND SECURITY REQUIREMENTS. PENETRATION PUTS GALVANIZED STEEL 1/8', 24X48, MCMASTER 89431(32 J.tgs://www.mcmaster.com/#standard—steel—sheets/=1 b5rlp7 1/2' SQUARE STAINLESS STEEL TUBING, MCMASTER 89825K31 httos: //www.mcmaster.com/Istandard —stainless —steel—structural—tubing /=1b5ioog 10X1 1/4 SELF DRIWNG COUNTERSUNK STAINLESS STEEL SCREWS, MCMASTER 94195A177 httos://www.mcmaster.com/#tapping—screws/=1b5 isgd. ROOM GROUND AND BONDING BRAIDS 1/2-13 BRASS THREADED ROD, 1', MCMASTER 93025A295 https://www.mcmaster.com/Ithreaded—rods/=1b5ii1q 1/2' BRASS WASHERS, MCMASTER 92916A420 httos://www.mcmaster.com/jstandard—washers/=1b51tj4 1/2' BRONZE LOCK WASHERS, MCMASTER 93496A433 httas://www.mcmaster.com/Istandard—washers/=1b78sib 1/2-13 BRASS HEX NUTS, MCMASTER 92676A470 https://www.mcmaster.com/Ohex—nuts/=1b5lupk https;//www.mcmaster.com/Ihex—nuts/=1 b5lupk GROUNDING BRAID, 2/0 EQUIVALENT, MCMASTER 69925K43 https://www.mcmaster.com/ibonding —and—grounding —eauioment/=1 b9a171 AC POWER FILTER 208/120V 60HZ BOA 3 PHASE (4 FILTERS), 100DB FROM 15 KHZ — 10 GHZ. UNIVERSAL SHIELDING USC -50-6084. COST IS APROX. ;6500. • SPECIFY 2" ALL—THREAD NIPPLE FROM REAR OF CABINET AND REQUIRED LENGTH. • THIS PARTICULAR ONE IS FED FROM THE BOTTOM AND FILTERED OUTPUT COMES OUT THE TOP REAR. • I DON'T BELIEVE R IS UL USTED, SO IT MAY REQUIRE A WASHINGTON NRTL BLESSING. POC: IRWIN NEWMAN/ALFONSO NOCERA 631-667-7900 JnfoOuniversalshielding.corn www.universalshielding.cont OTHER POWER FILTER SOLUTIONS: GENISCO GFP68216 INDUCTIVE INPUT FILTER httD://www.genisco.com/products/Dower—line—filter—panels/gf68201 /gf68216/ ETHERNET FILTERS FOR CAT5E TYPE CABLE, GIGABIT SPEED AND IDEALLY 10/100/1000 BASET SUPPORT. 100DB FILTERING FROM 15 KHZ — 10 GHZ. UNIVERSAL SHIELDING GIGAFOIL V3 USC -1061. COST IS APPROX ;1350 EACH. httD://www.universalshielding.cam/ (SEE CONTACTS IN POWER FILTER SECTION). ANALOG PHONE FILTER DUAL UNE, 100 DB FROM 15 KHZ — GHZ. GENISCO GF58270-1 (RAMAYES.COM IS A SOURCE) httD://www.aenisco.com/products/communication—filters/ THERMOSTAT FILTER TBD UNTIL WE HAVE HVAC SIGNAL DETAILS. SUGGEST SOMETHING IN THE GENISCO UNE, MOST UKELY A DIGITAL FILTER: http://www.genisco.com/oroducts/communication—filters/ FIBER WAVEGUIDES REQUIRE SUPPORT FOR 6 TERMINATED FIBERS IN THICK WALL 1OGHZ OR HIGHER. FBERPLEX WGF-6 WAVEGUIDE httos://www.fiberDlex.com/products/wgf-6 waveguide-27—ghz-6—channel DRYWALL SCREWS ANY FINE THREAD BLACK PHOSPHATE COATED DRYWALL SCREWS ARE ACCEPTABLE OR, STEEL STRIP—RESISTANT DRIWNG SCREWS FOR JOINING DRYWALL TO METAL FRAMING, MCMASTER 92050A500 AND 92050A600 httos://www.mcmaster.com/#taooing—screws/=1b5lkit HVAC WAVEGUIDE (3/16 HONEYCOMB) httD;//www.ets—lindgren.com/products/shielding/govemment—shielding/rf—shielded—accessories—for—government/11002/1100201 CAULK AND GASKETS RF CAULK AND THREAD SEALER, LAIRD ECCOSHIELD W httD://Dh.Darker.com/us/en/cho—band-1019two—component—electrically—conductive—silver—plated—aluminum—Dolvthioether— sealant/50-01-1019-0000 or https://www.auietrock.com/oroducts/auietseam—rf USEFUL WEBSITES. httos://www.djmelectronics.com/ethemet—emi—rfi—filter.htmt (GIGA FOIL FILTER) httos://www.fiberolex.com/products/tonic/waveguides (FIBER WAVEGUIDES) http://www.gavenindustries.com/comoonents.html (HVAC WAVEGUIDES, PENETRATIONS, FILTERS) http://www.raymondemc.ca/products/Droducts6a.htm16 (HVAC WAVEGUIDES) http://www.ets—lindgren.com/products/shielding/govemment—shielding /rf—shielded—accessories—for—govemment (HVAC WAVEGUIDES, PENETRATIONS, FILTERS) EXISTING HARD UD CEILING CONSTRUCTION. BASE LAYER 5/8' TYPE X GWB OR GYPSUM VENEER BASE APPUED PARALLEL OR AT RIGHT ANGLES TO EACH SIDE OF STEEL STUDS AT 16' O.C. TYP WITH HORIZONTAL BRACING AT 4'-0' WITH 1' TYPE S DRYWALL SCREWS AT 12' 0.C., DOES NOT NEED TO BE TAPED. FACE LAYER 5/8' TYPE X GWB OR GYPSUM VENEER BASE APPUED AT RIGHT ANGLES TO EACH SIDE OF STEEL STUDS AT 16' 0.C. TYP WITH 1' TYPE S DRYWALL SCREWS AT 12" O.C., JOINTS STAGGERED 24" EACH LAYER AND SIDE. SOUND TESTED WITH 3 1/2' ROXUL FIBER INSULATION FRICTION FR IN STUD SPACE., RECEIVED CITY OF TUKWILA NOV 2 9 2018 PERMIT CENTER FIBERPLEX WCN-6 AND WET -18A EXTENSION TUBES https://www.fiberolex.com/products/web wavegyide—extension—tubes FIBERPLEX WCN-6 COUPLING NUT httos://www.fiberplex.conl/products/wgn waveguide—nuts WGF-6 AND COUPUNG NUTS HAVE 1 1/8-18 NEF THREADS WHICH ARE UNCOMMON EXTRA FINE THREADS. FOILS AND TAPES ULTRA NT SCIF BARRIER SOUD (NOT PERFORATED) FOIL 48' X 125' (APPROX. 250' PER ROOM). PART NUMBER 1800-48-1255. DO NOT SUBSTITUTE. htto://www.ultrantscifbarrier.com/ultra—nt—self—barrier—soliid—a/ultra —nt.htry EMI SHIELD 4' CONDUCTIVE PSA AL5 TAPE, (2 ROLLS/ROOM BUT CHEAPER TO BUY 5 ROLLS TOTAL). httD://www.romoyes.com/aluminum foil emi rfi shielding.htm REVIEWED FOR CODE COMPLIANCE APPROVED DEC 052018 City oiwila BUILDING DIVISION 4" RESILIENT BASE (BOTH SIDES) EXIST. CONCRETE SLAB COPE GWB TO DECK ABOVE WITH 1/2' BEAD ACOUSTIC SEALANT METAL DEFLECTION TRACK (11 1/2' SLOTS TO ALLOW 3/4" MOVEMENT UP AND DOWN) FULL DEPTH ROXUL ACOUSTIC FIRE BATT INSULATION PIPE OR CONDUIT ACOUSTICAL CAULKING — CONTINUOUS FULL DEPTH OF GWB, EACH LAYER FULL CIRCUMFERENCE, BOTH SIDES RADIO FREQUENCY BLOCKING FOIL — CONTINUOUS BETWEEN LAYER OF GWB AT INTERIOR FACE OF WALL ALL WIRE OR CABLE UTILITIES (POWER, SIGNAL, TELEPHONE, NETWORK, ETC) MUST BE SURFACE MOUNTED RETAINER ANGLE WITH ACOUSTICAL CAULKING CONTINUOUS FULL WIDTH AND HEIGHT, BOTH SIDES (TYP) DUCT DUCT ACOUSTICAL SOUND UNER INTERIOR BASE RUNNER TRACK SET IN ACOUSTICAL CAULKING CONTINUOUS FULL LENGTH TO CONCRETE SLAB ACOUSTICAL CAULKING — CONTINUOUS FULL DEPTH OF GWB, EACH LAYER, BOTH SIDES ALL PENETRATIONS THROUGH SCIF WALLS SHALL BE KEPT TO A MINIMUM. UTILITIES SHOULD NOT CROSS WALL INTO SCIF MORE THAN ONCE. DO NOT INSTALL PENETRATIONS FOR FUTURE USE. ALL MATERIALS USED IN CONSTRUCTION OF THE SECURITY WALL SHALL BE DOCUMENTED. EDGES SEALED AND OVERLAPS DESIGNED TO SCIF STANDARDS. CONTACT BOEING SECURITY FOR VISUAL AND PHOTOGRAPHIC VDOCUMENTATION OF THE MEANS AND METHODS OF CONSTRUCTION BEFORE CLOSING ANY SCIF WALL. STC 55 GA. FILE NO. WP1522 FOR SOUND RATING ONLY. PLAN VIEW A SCALE: 3"= i'—O" 1A115 ISSUE FOR CONSTRUCTION 10.02.18 SYN w DAN SYR 11N7 U18 W5787983 x/ROLLUDA 10.02.18 ?I__AFAVEZAVIPP° ACCEPTABILITY TNS DESxRI AND/OR SPECIFrA1aN 0 APPROVED ECRANSraN CRACKED MISCELLANEOUS SECTIONS AND DETAILS REv90F1 W5787963 10.02.18 APPROVED BY DEPT. DAIS SFA1E OF WASHINGTON CNECMD IAP 11N7 LAB BUILDING 09-098 SHEET A515 JOB NO. WE7D70C1 COMP NO. QD 1-1/2'PW 4'W UP /4'PW U 2'PW DN W/BALL VALVE 1ABV WALL 2-1/2' ;YARD HYDRANT & 1IRRIGATION CONTROL (TYPICAL) 2-1/2' CHUB D "SAN. D 3'SAN. D 2 P-7.1 P-7 CO W/ACCESS DOOR i3'RD UP&DN - + MANHOLE ACCESS, SEE 3/M507 _12-1/2' DOUR CHECK VALVE 1M450/1M451 COMPOSITE FIRST FLOOR PLUMBING PLAN SCALE: 1/16'= 1 -0 REVIEWED FOR CODE COMPLIANCE APPROVED DEC 0 5 2018 • City of Tukwila BUILDING DIVISION FSi consulting engineers Seattle, Washington Solutions & Service - -1— I RECEIVED CITY OF TUKWILA NUV 2 9 2018 PERMIT CENTER IFC DESIGN SUBMITTAL 10.02.18 LEGEND — A — COMPRESSED MR. PUNT — C — CONDENSATE RETURN (GRAVITY) — CW - — HW — DOMESTIC HOT WATER SUPPLY — HWC — DOMESTIC HOT WATER CIRCULATING —PW — PROCESS WATER —RD— ROOF DRAIN — V — VENT — W — WASTE O VENT THROUGH ROOF O FCO FLOOR CLEANOUT FLOOR DRAIN 101 BALL VALVE, OPEN or- PIPE ELBOW, TURNED UP OR TOWARD C— PIPE ELBOW TURNED DOWN OR AWAY POINT OF CONNECTION CAP DOMESTIC COLD WATER GENERAL NOTES REFERENCE DRAWINGS 1M450, ENLARGED TOILET ROOM DOMESTIC WATER PLANS 1M451, ENLARGED TOILET ROOM DRAINAGE PLANS 1M452, ENLARGED MECHANICAL ROOM PLANS M313, PLUMBING DIAGRAM CONSTRUCTION NOTES WALL PENETRATION TO COMPLY WITH SCIF CONSTRUCTION REQUIREMENTS. ® PROVIDE FILTER AND PRESSURE REGULATOR ON INISDE WALL © ROUTE COMPRESSED AIR ALONG WALL. E> PROVIDE TWO (2) 3/8' PARKER EZ -MATE SERVICE QUICK DISCONNECTS, 1YP. EACH DROP LOCATION. VALVE AND QUICK DISCONNECTS TO BE LOCATED 46' AFF. 0 0 0 0 4 411 PLAN SNE N 16' 8' 0 8' 16' SCALE: 1/16'=1'-0' 32' ONE SYR REDRAWN KB 01.15.97 A 9-98 RENOVATION J/140799-00 COFFMAN M. SOTURA 09.15.09 RECORD DRAWING 4140799-00 COFFMAN M. SOIURA 07.23.07 ACCEPTABILITY TN6 COON NO/OR SPECIFICATION 6 APPROVED APPROVED eV DEPM. OATS KRNON KEIUN amacED DATE 1.15.97 CHECKED COMPOSITE FIRST FLOOR PLUMBING PLAN 11N7 LAB RI III nlMr, 9-9R 1 OMMNT REVEWIN MEM W5787963 DATE 10.02.18 1M3 JOB NO. COMP NO. TRANSITION AS NECESSARY H-0/330 10 10CD H-0 900 C-800 1645 C-150/400 H-0 330 C-80 295 H-0 1020 C-970 1940 14x14 10 TON H-0 160 C-150 360 C-230 950 H-0 25 C-675 1350 a , 40, �.11. 112 r�r� /.....:'� _11 C-530 1060 H-0 410 C-390 1120 H-0 120 42/20 LEGEND Eo SQUARE CEIUNG DIFFUSER LINEAR SLOT DIFFUSER i H-0/510 C-80/925 ROUND CEIUNG DIFFUSER CEILING GRILLE RETURN OR EXHAUST THERMOSTAT — WALL MOUNTED DUAL—DUCT VAV TERMINAL UNIT VOLUME DAMPER CO2 SENSOR PRESSURE TRANSMITTER DIFFUSER/GRILLE TAG. TOP NUMBER INDICATES TYPE, BOTTOM NUMBER INDICATES CFM. SEE DIFFUSER AND GRILLE SCHEDULE. VARIABLE VOLUME TERMINAL UNIT TAG. HOT AND COLD DUCT MINIMUM AND MAXIMUM CFM VALUES INDICATED. SEE DETAIL 5/M505 FOR ADDITIONAL INFORMATION. GENERAL NOTES RETURN AIR PATH ABOVE MECHANICAL ROOM 11V7 TO RETURN AIR SHAFT AT SECOND FLOOR. COLD DUCT INLET SIZE SHALL BE AS SCHEDULED ON DWG M2C UNLESS INDICATED ON THIS DRAWING. HOT DUCT INLET SIZE SHALL AS PER DETAIL ON DRAWING M505 AND BE BASED ON THE HOT DUCT MAXIMUM CFM INDICATED UNLESS SIZE IS INDICATED ON THIS DRAWING. AIR BALANCING SHALL BE DONE WITH MAXIMUM COOUNG AIRFLOW AND HOT AIR DECK CLOSED. IN HEATING MODE DIFFUSER AIRFLOW CAN BE SLIGHTLY HIGHER THAN COOLING AIRFLOW. TRANSFER GRILLE MOUNTED IN WALL ABOVE CEIUNG, 90 WITH SOUNDUNED BOOT. SEE DETAIL 1/M506. ® SEE 1M11 FOR DIFFUSERS IN THESE ROOMS. C-800 1595 36/14 UP 44/20 UP 36/14 UP 26/12 DUE SYR 140 EXHAUS- UP FIRST FLOOR DUCTWORK PLAN O SCALE 1/8'= 1'-0. Br APPRO.ED NCE REDRAWN K. BUN 01.15.97 E FIX DUCT WISE 4703445-15 M.WONG RSOUI IES 04.30.03 A 9-98 REWORK OFFICE AREA 4180166-04 CFH 03.04.99 F 9-98 RENOVATION 4140799-00 COM/AN N.S0111RA 08.15.06 8 RELOCATE DIFFUSER J1190077-03 DIN/RHs 08.18.99 RECORD DRAWING 4140799-00 COFFMAN M. SOIURA 07.23.07 28/12 REMOVAL BOE/A/G' 34/12 38/12 • CEI 4/ EI) CITY OF TUKWILA NOV 2 9 2018 PERMIT CENTER illi0 FSi consulting engineers Seattle, Washington ACCEPTABILITY TNsOUIIX1D46AND SPECFI Solutions & Service APPROVED BY DEPT. DME DRAWN K.BUN PATE 1.15.97 REFERENCE DRAWINGS REVIEINEDPORcAL CODE COMPtlasift APPROVED DEC 0 5 2018 City of Tukwil 13 . IVISIOF L REMOVAL NOTES REMOVE EXISTING SUPPLY DIFFUSERS AND RETURN GRILLES WITHIN LAB SPACE. MAINTAIN EXISTING DUCT CONNECTION FOR FUTURE MR TERMINALS. PROTECT ALL DUCTWORK FOR FUTURE CONNECTIONS. REMOVE EXISTING TERMINAL UNIT AND PNEUMA11C CONTROLS, TYP 6. IFC DESIGN SUBMITTAL 10.02.18 FIRST FLOOR DUCTWORK PLAN HEDULES 0 1M11 0 O jM 12// 11,113 0 KEY PLAN Q SCALE: NOME 8' 4' 0 4' 8' SCALE: 1/8"=1'-0" 1/8'=1'-0' CRHmR RBOKM W5787963 PROM 16' DA 10.02.18 CHECKED 11N7 LAB BUILDING 9-98.1 1M12R JOO N0. TRANSTDON AS NECESSARY 10 O® H-0 LEGEND ©O SQUARE CEIUNG DIFFUSER Q 0 LINEAR SLOT DIFFUSER ROUND CEIUNG DIFFUSER CEILING GRILLE RETURN OR EXHAUST THERMOSTAT - WALL MOUNTED 400 H-0 C-80 295 H-0 1020 C-970 1940 14x14 !i1I VI!P IS- J.lIre I9 o:1l0r1[115FM6LA, Li.ret i /1 l►J\►n l�li! \ 00 950 H-0 215 C-205 625 H-0 H-0 160 C-150 360 MIE ff C-530 1060 C-675 1350 55 36/14 36/14 1M121M519 1M121M519 1M121M519 1M12 M520 144 EXHAU UP FIRST FLOOR DUCTWORK PLAN O SCALE: 1/B•= 1'-0' pr J 28/12 34, REVIEWED FOR 28/12'' CODE COMPLIANCE APPROVED DEC 0 5 2018 City of Tukwila tita 16'sM,�fd4dlf' N NEI Solutions & Service H-0 840 C-800 1595 O DUAL -DUCT VAV TERMINAL UNIT - VOLUME DAMPER • CO2 SENSOR e PRESSURE TRANSMITTER NET H-0/510 CITY OF RECEIVED NOV 292018 PERMIT CENTER C-80/925 DIFFUSER/GRILLE TAG. TOP NUMBER INDICATES TYPE, BOTTOM NUMBER INDICATES CFM. SEE DIFFUSER AND GRILLE SCHEDULE. VARIABLE VOLUME TERMINAL UNIT TAG. HOT AND COLD DUCT MINIMUM AND MAXIMUM CFM VALUES INDICATED. SEE DETAIL 5/M505 FOR ADDRIONAL INFORMATION. GENERAL NOTES E> RETURN AIR PATH ABOVE MECHANICAL ROOM 11V7 TO RETURN AIR SHAFT AT SECOND FLOOR. => COLD DUCT INLET SIZE SHALL BE AS SCHEDULED ON DWG M2C UNLESS INDICATED ON THIS DRAWING. HOT DUCT INLET SIZE SHALL AS PER DETAIL ON DRAWING M505 AND BE BASED ON THE HOT DUCT MAXIMUM CFM INDICATED UNLESS SIZE IS INDICATED ON THIS DRAWING. AIR BALANCING SHALL BE DONE WITH MAXIMUM COOUNG AIRFLOW AND HOT MR DECK CLOSED. IN HEATING MODE DIFFUSER AIRFLOW CAN BE SLIGHTLY HIGHER THAN COOLING AIRFLOW. TRANSFER GRILLE MOUNTED IN WALL ABOVE CEILING, WITH SOUNDUNED BOOT. SEE DETAIL 1/M506. 1 4 > SEE 1M11 FOR DIFFUSERS IN THESE ROOMS. REFERENCE DRAWINGS M2C, MECHANICAL SCHEDULES M505, HVAC DETAILS CONSTRUCTION NOTES ALL CONTROLS WIRING TO BE SHIELDED. RF SHIELDED WALL PENETRATIONS TO COMPLY WITH SCIF CONSTRUCTION REQUIREMENTS, TVP. © BALANCE NEW DIFFUSERS AS SHOWN. MAINTAIN SCIF ENCLOSURE ABOVE HARD UD CEIUNG. INSTALL VAV BOXES SO THAT 36* CLEAR CONTROL PANEL ACCESS IS MAINTAINED. TYP. PAINT VAV BOXES AND DUCTWORK TO MATCH ARCHITECTURAL REQUIREMENTS. TYP. IFC DESIGN SUBMITTAL 10.02.18 KEY SCALE:NONE�N N 8' 4' 0 4' 8' SCALE: 1/8'=1'-0' 16' BY APPROVED DOE m By APPROAD DATE REDRAWN K.BUN 01.15.97 E FIX DUCT NOSE 4703445-15 M.WONG R.SOUIRES 04.30.03 A 9-98 REWORK OFFICE AREA 4180166-04 CFH 03.04.99 F 9-98 RENOVATION 4140799-00 COffYNN M.SOTURA 08.15.06 8 RELOCATE DIFFUSER 4190077-00 DNV/RWS 08.18.99 RECORD DRAWING 4140799-00 COFFMM M. SOTURA 07.23.07 BOE/A/43' E ACCEPTABILITY K° B N a1 15.97 INS DESIGN AND/0R GROMED SPECJF101110N 6 APPROVED - APPROVED BY DEPT. DAVE FIRST FLOOR DUCTWORK PLAN CURRENT REVISION W5787963 MINIX DDE 10.02.18 NECKED 11N7 LAB BUILDING 9-98.1 SHEET 1M12 AMINO. COMP ND. 'TY 11 10 CXD 2 1/2' 1 1/4" - 3 2 1 /4. 1 1/4" 1' 1&11 1/4" 1 1 1` 1 1/4" , 1 1 .l s v r. --4-*h r 1' t 1 1/4" 4' ;. 1 1/4.1 1 1(4"1' - 1" 1• m 111/4•-. 11 1' f 1 1/4" /4• , 1 1/4• ? - 1" 1" T 1 1/4" -1 1 1(4" t 1_ DAIS 1 1/4"f - 1- 1't 1 1 /4' 1 114. t 1' FLOOR PLAN SCALE: 1/86=1.-0" A 11N7 LAB 85787983 10.02.18 gl_ANSFEIrAfA7' • FSi consulting engineers Washington oshington Solutions & Service ACCEPTABILITYDRAWN K. BUN EIS oma No SPECIFICATION 6 `M__. APPROVED Ft DEFT. DIE CHECKED 1/15/97 1.) LEGEND: SPRINKLER HEAD 2 -WAY EARTHQUAKE BRACING X4 -WAY EARTHQUAKE BRACING PIPE HANGER ® SPRINKLER RISER GENERAL NOTES: NOTIFY BOEING FIRE DEPT. 24 HOURS PRIOR TO SHUTDOWN. 2.) FOR EARTHQUAKE BRACING USE 1" STEEL PIPE FOR BRACES UP TO 7'-0" LONG & 1-1/4" PIPE FOR BRACES 7'-1" TO 9.-0• LONG. FLATTEN AND DRILL ENDS FOR MOUNTING. O CONSTRUCTION NOTES: ORDINARY HAZARD GROUP II, 0.20 GPM/FT2 AT 1500 SF. RELOCATE FP HEADS AS REQUIRED TO ACCOMMODATE REVISED LAYOUT. REVIEWED FOR CODE COMPLIANCE APPROVED DEC 052018 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA NOV 29 2018 PERMIT CENTER IFC DESIGN SUBMITTAL 10.02.18 FIRE PROTECTION PLAN KEY PLAN MILD NEE aREM W5787953 DAVE 10.02.18 11N7 LAB BUILDING 9-9R.1 1M262 MB NO. 6"0 SAN. SEWER HUB DRAIN SEE 1M3 FOR CONTINUATION P.O.C. )4"CW TO TRAP PRIMER J¢" FROM TRAP PRIMER TO HUB DRAIN COFFEE WATER SUPPLY CONNECTION WATER FILTER IN CASEWORK HW CAFE 11D6 SEE 1M3 FOR CONTINUATION EN 9 1/2"HW & CW TO FIXTURE INFRARED POWER TRANSFORMER W/ SHUT-OFF SWITCH (120V-10) CT. 2-1/2"CW UP STORAGE & CW TO FIXTURE 3/4" 2-1/2" 2-1/2" 3/4"HWC UP 1/2"HW & CW TO FIXTURE 1-1/4"CW 1/2"CW 1/2"HW & CW TO FIXTURE ACCESS DOOR, 14"x14" TO TRAP PRIMER & WATER FILTER WATER FILTER & TRAP PRIMER IN WALL CAVITY W/ ACCESS ' DOOR (WATER COOLER CW) SEE 1M3 FOR CONTINUATION -1/2" SEE 1M3 FOR CONTINUATION 1ST FLOOR TOILET ROOM - WEST n N SCALE: 1/4"= 1'-O" 1A13 1M450 O O CD A SEE 1M3 FOR CONTINUATION CAFE 12S6 OFFEE WATER PPLY CONNECTION WATER FILTER IN CASEWORK VAI SEE 1M3 FOR CONTINUATION 2-1/2" 2-1/2" INFRARED POWER I v u TRANSFORM R W/ SHUT-OFF WITCH TO FIX & CW (120V-10) t� ' TO FIXTURE 1 401Mf' P-8 13- �— I� Wiwi 1/2"HWFICWTO I •j FIXTURE Foil r • ELECT. 3/4"PW UP TO PENTHOUSE CONF I 1: — I STORAGE NOE 2-1/2"CW UP 2-1/2" P-1 (TYP) 1/2"HW & CW TO FIXTURE IIiOR 1151. 1 111 i IJiuIII!1 (-`i' 1/2"HW & CW i'0 I FIXTURE 3/4" HWC UP LEGEND —CW — DOMESTIC COLD WATER — HW — DOMESTIC HOT WATER SUPPLY — HWC — DOMESTIC HOT WATER CIRCULATING — PW— Lel PW— I> 1 0 14:6I PROCESS WATER BUTTERFLY VALVE VENT THROUGH ROOF WATER HAMMER ARRESTOR BALL VALVE, OPEN o� PIPE ELBOW, TURNED UP OR TOWARD C� PIPE ELBOW TURNED DOWN OR AWAY GENERAL NOTES CONSTRUCTION NOTES 1/4"HW UP CORIDO ACCESS DOOR, 14"x14" TO TRAP PRIMER & WATER FILTER WATER FILTER & TRAP PRIMER IN WALL CAVITY W/ ACCESS DOOR (WATER COOLER CW) 2-1/2" SEE 1M452 FOR CONTINUATION r'7 A 1 1ST FLOOR TOILET ROOM - EAST n cr)SCALE: 1/4"= 1'-0" 1M3 1M450 Ihi• FSi consulting engineers Seattle, Washington Solutions & Service SEE 1M3 FOR CONTINUATION REVIEWED FOR CODE COMPLIANCE APPROVED DEC 0 5 2018 City of Tukwila BUILDINGI'sD CIIYu- IUK VILA IFC DESIGN SUBMITTAL 10.02.18 NOV 2 9 2018 PERMIT CENTER REFERENCE DRAWINGS M2B, MECHANICAL SCHEDULES 1M3, COMPOSITE FIRST FLOOR PLUMBING PLAN 1M452, ENLARGED MECHANICAL ROOM PLANS 2M450, ENLARGED TOILET ROOM DOMESTIC WATER PLANS M313, PLUMBING DIAGRAMS M314, PLUMBING DIAGRAMS KEY PLAN N0€ N 4' 2' 0 2' 4' SCALE: 1/4"=1'-0" 8' Sem APPNOND DATE SAM ax A 9-98 RENOVATION 4140799-00 COFFMAN M.SOIURA 08.15.06 RECORD DRAWING 4140799-00 COFFMAN . SUTURA 07.23.07 B INSTALL TRAP PRIMERS 10170242 M.WONG RWS 05.04.10 ACCEPTABILITY NB DESIGN AND/OR SPECFlCA110N IS APPROVED APPROVED BY DEPT. DATE DRAWN COFFMAN LIA.SSOTURA DATE 07.25.06 07.25.06 CHECKED APPRCNEO SOME ENLARGED TOILET ROOM DOMESTIC WATER PLANS "'s 11N7 LAB BUILDING 9-9R_1 CURRENT MASON W5787963 SYMBOL C DAH: 10.02.18 SHEET 1 M45 COMP N0. 1"MPS 601 2-1/2"PC — (3)3/4"C DN TO DRAIN 14x14 SOUNOUNED TRANSER BOOT, SEE 1/14506 16x16 4"FC0 4" LPC 44 3/4"A--.-1 14x12 EXHAUST DUCT 125 MPC 18x14 1 ST FLOOR MECH - 1 1 J6 n N SCALE: 1/2"= 1'—O" 1143, 11411, 11461 114452 SEE 1N451 FOR CONT. �6"W (6 W ABANDONED BELOW) 3"V UP &DN 8"F BELOW SLAB 3/4"A UP 16x16 CEILING MOUNTED PROVIDE DRY PIPE SPRINKLER ALARM VALVE & SYSTEM AUTOMATIC WET FIRE SPRINKLER ALARM VALVE N LL 3/4" 601 MPS TO PUMPS SUMP PUMP, SEE 3/1M452 PRV-3, SEE DETAIL 2/11509 WATER SERVICE ASSEMBLY (RPBA & PRV), SEE 14314 _�Xt"CW TO TRAP PRIMER LADDER r3/4"A DN TO PIT W/HOSE END VLAVE & DIRT LEG ± 36" ABOVE FLOOR WITH 14"0 EXHAUST DUCT FROM SHAFT ABOVE —5" DUCT (20 GA.) DN TO 4' AEOVE PIT LEVEL W/MESH SCREEN AT BOTTOM OOR 1 VENT \-3" VTR UP TO ROOF 4" MPS UP TO 2ND FLOOR 2-1/2" PUMPED MPS / CONDENSED TO 4"STEAM 1251 (BELOW SLAB) J CENTRAL PLANT 1ST FLOOR MECH - 11 V7 N SCALE: 1/2"= 1'-0" UGM3, 1143, 11113, 1M63 11452 4j LEAD FLASHING 12" ALL AROUND SLEEVE 2"W (GALV PIPE) IN ZURN Z-195-3 FLASHING SLEEVE 2"CHECK VALVE SUMP PUMP — CAPACITY 35 GPM 0 15' HEAD—AU. BRONZE, SEMI—OPEN IMPELLER, 1 1/4" DISCHARGE, 1/3 HP, 1800 RPM, 115 VOLTS, SINGLE PHASE, BUILT—IN OVERLOAD PROTECTION, BUILT—IN FLOAT SWITCH— PACIFIC PUMP TYPE ASM. 4" WASTE FROM MHI2 EL 6.25' SUMP PUMP PLAN n SCALE: 1/2"= 1'-0" 11.1452 FSi consulting engineers Seattle, Washington Solutions Sr Service LEGEND — A COMPRESSED AIR. PLANT — C — CONDENSATE RETURN (GRAVITY) CW DOMESTIC COLD WATER —CW — DOMESTIC COLD WATER BELOW GRADE — F FIRE UNE F — ARE UNE, BELOW GRADE OR FLOOR LPC LOW PRESSURE CONDENSATE —MPCMEDIUM PRESSURE CONDENSATE —MPSMEDIUM PRESSURE STEAM —PC— CONDENSATE RETURN (PUMPED) V VENT W — WASTE W — WASTE BELOW GRADE O VENT THROUGH ROOF 0+— PIPE ELBOW, TURNED UP OR TOWARD c PIPE ELBOW TURNED DOWN OR AWAY $ POINT OF CONNECTION RETURN OR EXHAUST AIR FLOW DIRECTION STEAM TRAP o- BALL VALVE WITH HOSE END VOLUME DAMPER GENERAL NOTES STEAM CONDENSATE EQUIPEMENT IS IN A 7' DEEP PIT. PIT IS 67"x73" WITH A FLOOR GRILLE ON TOP. REFERENCE DRAWINGS UGM3, COMPOSITE UNDERGROUND PLUMBING PLAN 1M3, COMPOSITE FIRST FLOOR PLUMBING PLAN M314, PLUMBING DIAGRAMS 1M61, FIRST FLOOR IiVAC PIPING PLAN 1M63, FIRST FLOOR IiVAC PIPING PLAN CONSTRUCTION NOTES CONNECT 3/4" COMPRESSED AIR UNE TO EXISTING PIPING. O RECEIVED CITY OF TUKWILA NOV 2 9 2018 PERMIT CENTER REVIEWED FOR CODE COMPLIANCE APPROVED DEC 0 5 2018 City of Tukwila BUILT: G ISION IFC DESIGN SUBMITTAL 10.02.18 KEY PLAN O SCALE: NONE SYM KISCO Fr( INROAD DOE A 9-96 RENOVATION 4140799-00 COFFIIAN M. SOIURA 0&15.06 RECORD DRAWING 4140799-00 COMM M. S01U(A 0753.07 INSTALL TRAP PRIMERS 10170242 M.WONG RWS 05.04.10 re'LiroweAw• ACCEPTABILRY fl oEspl6 N TFPA1gN APPROVED eV DEPT. DATE DMA ELATE COFFMAN 07.25.06 SRA 07.25.06 CHECKED ENLARGED MECHANICAL ROOM PLANS 11N7 LAB RI I11 f1IN(; CI -AR 1 CURRENT R OEN W5787963 DATE 10.02.18 1 M452 JOB N0. COW ND. SIM DIFFUSER AND GRILLE SCHEDULE MARK MARK TYPE NECK SIZE NC MAXIMUM DESIGN CFM DUCT CONNECITON SIZE BASIS OF DESIGN REMARKS ROUND SQUARE CDI 24x24 SQUARE CEILING DIFFUSER 60 25 100 — — TITUS TMSA LAY—IN CEUNG CD2 24x24 SQUARE CEILING DIFFUSER 80 25 210 — — TITUS IMSA LAY—IN CEUNG D 24x24 SQUARE 1 2 : i — — T. —IN CE - G CD4 24x24 SQUARE CEIUNG DIFFUSER 12x12 25 380 — — TRUS MCD LAY—IN CEIUNG AG -95 OPPOSED BLADE DAMPER 10 SEE NOTE 6 CEILING DIFFUSER 12x10 65 60 - - P r `_ aE CD6 LINEAR SLOT CEILING DIFFUSER 100 25 235 — — TITUS TBDI-30 4'-0" LONG (3) 1' SLOTS CD7 UNEAR SLOT CEIUNG DIFFUSER 120 25 280 — — TMJS TBDI-30 4'-0" LONG (3) 1' SLOTS CD8 NOT USED 72 60 59 NOT REQUIRED 10 F 450 CD9 ROUND DIFFUSER 80 25 210 — — TITUS TMRA 61 CD10 ROUND DIFFUSER 100 25 380 — — TITUS TMRA SEE NOTE 6 C011 12212 SQ CEIUNG DIFFUSER 80 25 240 TITUS TMSA SURFACE MOUNT CD12 24224 SQ CEIUNG DIFFUSER 100 25 380 TITUS TMSA SURFACE MOUNT CD13 UNEAR SLOT DIFFUSER 80 25 250 TINS FLOW BAR 4'-0' LONG (1) 1.5' SLOT SG1 HIGH WALL SUPPLY GRILLE SEE PLANS 25 SEE PLANS — — TINS 300RL RG1 CEIUNG RETURN GRILLE — 25 — — — TITUS 8R LAY—IN CELING RG2 CEILING RETURN GRILLE 12x12 25 1200 — — TITUS 350RL LAY—IN CEUNG ,I 1 1 RG4 NOT USED RG5 NOT USED RG6 NOT USED RG7 COUNG RETURN GRILLE 22x10 25 450 120 22x6 TITUS 350RL RG8CEIUNG 'RETURN GRILLE 22x16 I 25 1100 80 22x8 TITUS 350RL RG9 CEIUNG RETURN GRILLE 22x22 i 25 1650 80 22x12 TITUS 350RL RG10 NOT USED RG11 NOT USED RG12 SIDE WALL RETURN GRILLE 18x16 33 1250 — — TITUS 350RL RG13 SIDE WALL RETURN GRILLE 14x18 29 750 — — TITUS 350RL EG1 CHUNG EXHAUST GRILLE 8x8 25 200 80 8x6 TITUS 350RL EG2 CEIUNG EXHAUST GRILLE 10210 25 350 100 12x6 TINS 350RL EG3 NOT USED 25 500 120 14x8 TINS 350RL EG4 NOT USED EG5 NOT USED EG6 NOT USED EG7 COUNG EXHAUST GRILLE 22x10 25 700 120 22x6 TITUS 350RL EG8 NOT USED EG9 NOT USED EG10 NOT USED EG11 NOT USED EG12 HIGH WALL EXHAUST GRILLE SEE PLANS 25 SEE PLANS — — TITUS 350RL TG1 HIGH WALL TRANSFER GRILLE SEE PLANS 25 SEE PLANS — — TINS 350RL DUAL DUCT TERMINAL UNIT SCHEDULE MARK COLD DUCT HOT DUCT OUTLET DUCT SOUND POWER ADDITIONAL SOUND ATTENUATION REMARKS TYPICAL SETPOINT RANGE ('OLD DECK BOX) COLD DUCT BRANCH SIZE MAXIMUM HOT DUCT CFM (PER PLANS) HOT DUCT INLET SIZE 2 4 6 LOWEST MIN. HIGHEST MAX. INLET SIZE A 50 170 4 6 SEE NOTE 6 SEE NOTE 6 12x8 64 56 56 NOT REQUIRED 63 B 80 340 6 8 SEE NOTE 6 SEE NOTE 6 12x8 62 59 56 NOT REQUIRED K C 150 700 8 10 SEE NOTE 6 SEE NOTE 6 12x10 65 60 58 NOT REQUIRED 10 D 230 1000 10 12 SEE NOTE 6 SEE NOTE 6 14214 72 60 59 NOT REQUIRED 16 E 330 1400 12 14 SEE NOTE 6 SEE NOTE 6 16214 72 60 59 NOT REQUIRED 10 F 450 2200 14 16 SEE NOTE 6 SEE NOTE 6 20x16 73 61 61 NOT REQUIRED G 580 2600 16 18 SEE NOTE 6 SEE NOTE 6 24x16 73 61 61 NOT REQUIRED 1. DESIGN BASED ON TITUS DERV SERIES TERMINALS WITH FACTORY—INSTALLED CONTROLS FURNISHED BY CONTROLS SUBCONTRACTOR. 2. TERMINAL UNIT ASSEMBLY INCLUDES AIR VALVES, CONTROLLERS AND MIXING—ATTENUATOR SECTION. TERMINAL UNIT COLD AIR VALVES SHALL BE ABLE TO OPERATE AT ANY POINT WITHIN THE SETPOINT RANGE INDICATED IN THE SCHEDULE. INITIALLY SET MAXIMUM AND MINIMUM CFM'S AT VALUES INDICATED ON THE PLANS FOR EACH INDMDUAL TERMINAL 3. SOUND POWER VALUES SCHEDULED ARE THE MAXIMUM ALLOWED DISCHARGE SOUND POWER AT THE "MIXER—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• 2000 1 8000 SA -1 AHU-1 96X96 5 I 200 1100 8 12x12 78 73 63 NOT REQUIRED BASIS OF DESIGN: NAILOR D3001-8 J 50 475 8 10210 69 61 53 NOT REQUIRED BASIS OF DESIGN: NAILOR D3001-5 K 100 380 8 10x10 69 61 53 NOT REQUIRED BASIS OF DESIGN: NAILOR D3ORE-5, 3kW 480V COIL WITH SCR CONTROLS L 720 1140 10 14x12 74 66 58 NOT REQUIRED BASIS OF DESIGN: NAILOR D3ORE-9, 7.5kW 480V COIL WITH SCR CONTROLS 10 12 21 23 22 16 12 10 IAC MODEL CLEAN FLOW' TYPE HLFM SA -4 AHU-4 72X72 5 48X36 2 36X242 0.25 1150 35,000 10 1. AIRFLOW BASED ON EXISTING CONDITIONS. 2. DDC CONTROLLERS TO BE FACTORY MOUNTED NIAGRA MNB—V1 AND MNB—V2, PROVIDED BY OWNER. REVIEWED FOR CODE COMPLIANCE APPROVED DEC 0 5 2018 City of Tukwila BUILDING DIVISION RECEIVED I1t11.A CITY O NOV 29 218 PERMIT CENTER SOUND ATTENUATOR (SA) SCHEDULE NM g� AIR HANDLER UNIT ATTENUATOR BANK SIZE FT x FT LENGTH FEET UNIT WIDTH x HEIGHT INCHES MAXIMUM PD IN/H20 FV�M AIR QUANTITY CFM MINIMUM DYNAMIC INSERTION LOSS RATING, dB OCTAVE BAND CENTER FREQUENCY HERTZ BASIS OF DESIGN RATING 63 125 250 500 1000 2000 4000 8000 SA -1 AHU-1 96X96 5 48X48 (4) 0.25 1150 60,000 10 12 21 23 22 16 12 10 IAC MODEL 'CLEAN FLOW' TYPE HLFM SA -2 AHU-2 72X72 5 48X36 2) 36X242 ( 0.25 1150 35,000 10 12 21 23 22 16 12 10 IAC MODEL CLEAN FLOW" TYPE HLFM SA -3 AHU-3 96X96 5 48X48 (4) 0.25 1150 60,000 10 12 21 23 22 16 12 10 IAC MODEL CLEAN FLOW' TYPE HLFM SA -4 AHU-4 72X72 5 48X36 2 36X242 0.25 1150 35,000 10 12 21 23 22 16 12 10 IAC MODEL 'CLEAN FLOW' TYPE HLFM 1. REFER TO FLOOR PLANS FOR SIZES OF WALL AND DUCT—MOUNTED GRILLES AND REGISTERS. 2. DIFFUSERS SHALL NOT EXCEED NOISE CRITERIA (NC) PER THE SPECIFIED BASIS OF DESIGN MANUFACTURER'S TESTING STANDARDS, EXCEPT IN MECH RMS., ELEC RMS., & ELEV EQUIP RMS. 3. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR COORDINATION OF DIFFUSERS AND GRILLES WITH OTHER COUNG ELEMENTS. CONTRACTOR SHALL VERIFY CEIUNG TYPES IN ALL AREAS AND CONFIRM BORDER STYLES PRIOR TO ORDERING GRILLES, REGISTERS AND DIFFUSERS. REASIMI x NFSAFD DDE sru A 9-98 RENOVA1106l 4140799-00 COFFIIAN M. SOTURA 08.15.06 RECORD DRANK J1140799-00 COFF NN M SOTURA 07.23.07 B 11N7 1A8 W5787963 FSH 10.02.18 lii• ei consulting engineers SWashington Washington Solutions & Service ACCEPTABILITY 11#S OESEDI Prhits SPECIFICATION IS APPROVED BY DEPT. DATE TRIM COFFMAN � A DOE 07.25.06 07.25.06 IFC DESIGN SUBMITTAL 10.02.18 MECHANICAL SCHEDULES CUNDR ADIOWN W5787963 SYMBOL DATE 10.02.18 IDOLOPED APPROVED 1111E 11 N7 LAB BUILDING 9-98 SHEET M2C JOONO. 4AA,AA AA COMP ND. INSIDE KA ROOM STEEL PLATE OUTSIDE ICD ROOM 1/2' TO 3/4' PLYWOOD FOR PIPE SLEEVE END SUPPORT PIPE SLEEVE DETAIL CONDUIT NIPPLE CUT TO LENGTH PIPE PASSING THROUGH GROUND BUSHING RF GASKET SHORT NIPPLE SHIELD PLATE CONDUIT COUPLER LOCKNUT WASHER DRYWALL AND PLYWOOD BACKING • SLEEVE DIAMETER TO VARY BASED ON PIPE PASSING THROUGH. • APPLY RF CAULK TO THREADS OF NIPPLES IN COUPLER TO KEEP THEM IN PLACE. • POLISH COUPLER FACE ON A DISK SANDER OR FINE EMERY CLOTH ON GLASS PLATE IF IT IS ROUGH. • RF GASKET TO FILL VO) BETWEEN SHORT NIPPLE AND HOLE IN PLATE. • IF GROUND BUSHING WON'T HOLD COUPLER TIGHT TO SHIELD, USE WASHER AND LOCKNUT. • LOCKNUT AGAINST PLYWOOD TO BE FINGER TIGHT (FOR SLEEVE STABILITY ONLY). STUD (SIDE VIEW) • INDMDUAL PIPE SLEEVES REQUIRED FOR EACH PIPE/TUBE PENETRATION. • REQUIRED PIPE SLEEVES: • 1/2' FOR 3/8' HVAC TUBE • 3/4' FOR 5/8' HVAC TUBE • 3/4' FOR 1/2' HVAC CONDENSATE DRAIN • 1 1/4' FOR 1' SPRINKLER PIPE • SPACE ADJACENT SLEEVES NO CLOSER THAN 4' ON CENTER. • SLEEVE INSIDE DIAMETER TO BE APPROX. 1/4' LARGER THAN OD OF PENETRATION PIPE/TUBE. • SLEEVE LENGTH MUST BE AT LEAST 6 TIMES ITS INSIDE DIAMETER. • INJECT RF CAULK IN BOTH SIDES OF SLEEVE AROUND PENETRATING TUBE UNTIL COMPLETELY FILLED. CLEAN OFF EXCESS CAULK. • INSIDE ROOM, WRAP 4' FOIL SEAMING TAPE AROUND THE PIPE AND SLEEVE (CENTER OVER SLEEVE MOUTH) OTHER NOTES: • COORDINATE ALL PENETRATIONS WITH ARCHITECT • INSTALL PIPE PENETRATIONS IN DATA FILTER PENETRATION PLATE IN ORDER TO MINIMIZE THE NUMBER OF PLATES. • USE GALVANIZED RMC OR INC CONDUIT. • USE RF SHIELD FOAM FOR ANY GAPS IN PLYWOOD PENETRATIONS. 705 HVAC REFRIGERANT LINES, CONDENSATE, AND SPRIKLER PIPE PENETRATION DETAIL SCALE NONE 1M12 M519 L2'X2'X1/4' 1/4' LAG SCREW SECURE AREA SECTION O SCALE: NONE NOTE INSTALL INSPECTION PORT IN DUCTING, IN AN ACCESSIBLE LOCATION ON SECURE SIDE OF ROOM. FABRICATE FRAME FROM L 2X2X 1/4 112'0 CROSS BARS 6 O.C. EACH WAY WELD 0 BAR INTERSECTIONS TACK VELD NUT TO ROO 1/2' NUT 1/2'0 X 1 1/2' BOLT 1/2'0 NUT TACK WELD NUT TO BOLT (TYP.) FABRICATE FRAME IN (2) PIECES. BOLT PIECES TOGETHER IN FIELD ASSESS DOOR ON SECURE SIDE OF DUCT BUSKIN ADH12 — RECTANGULAR DUCT, RUSKIN ARDD — ROUND DUCT. EXISTING DUCT EXISTING DUCT 1/4"O LAG SCREW E}(TERIOR FRAME TO WALL ON SECURED SIDE (APROX. 12' O.C. OR 2 EA. LEG MINIMUM) NOTE: SIMILAR CONSTRUCTION SHALL BE USED FOR ROUND & OVAL DUCTS UNSECURED SIDE OF WALL SECTION 0 SCALE NONE ROUND AND RECTANGULAR DUCT SECURITY GRILLE DETAIL SCALE: NTS 1 M 12 M519 DALE SIN 11N7 U8 W5787983 F5 10.02.18 BOE/NQ' 1/2' GAP BETWEEN EDGE OF DUCT AND FRAMING DUCT INSIDE FRONT VIEW OF WALL DUCT FRAMING FLEX CONNECTION ACOUSTIC UNED Z DUCT INSIDE ICD ROOM INTERIOR 5/8 DRYWALL LAYERS INTERIOR WAVEGUIDE FLANGE 5 RF WAVEGUIDE OUTSIDE ICD ROOM ROOM EXTERIOR 5/8 DRYWALL FLEX CONNECTION STUD (SIDE VIEW) AIR DUCT ACOUSTIC FOAM GAP AROUND DUCT DUCT FRAMING • INSTALL BLOCKING IN STUD CAVITY WHERE DUCTS PENETRATE. BLOCK ABOVE, BELOW, AND TO THE SIDES LEAVING APPROX. 1/2' GAP TO DUCT. • INSTALL 1ST INTERIOR DRYWALL LAYER AFTER INSULATING STUD CAVITY. COORDINATE WITH ARCHITECTURAL. • SCREW 16-18GA SHEET METAL PLATE, WITH A CUTOUT FOR DUCT, TO BLOCKING SURROUNDING THE DUCT. SHEET METAL TO EXTEND 1.5' PAST BLOCKING TO PROVIDE SCREWING SURFACE FOR 2ND LAYER OF DRYWALL • PLACE WAVEGUIDE OVER PLATE AND SCREW DOWN WAVEGUIDE TO SHEET METAL PLATE INTERSECTION AND A SEPARATE TAPE LAYER CENTERING OVER WAVEGUIDE TO METAL PLATE INTERFACE. • SPRAY ACOUSTIC FOAM AROUND DUCT PENETRATION FROM OUTSIDE WALL. • ONCE 2ND LAYER OF DRYWALL IS INSTALLED, Z—DUCT AND ISO—COUPLER CAN BE ADDED. HVAC DUCT PENETRATION DETAIL SCALE: NONE • FSI consulting engineers Seattle, Washington Solutions & Service ACCEPTABILITr 01 0119.18 fl 0ES1411 wo/man SPET7F1 *1UI B AP 2tl w,,GLS 01.19.18 APPROVED BY DEPT. DATE GLS CHUCKED AWL APPROVED 01.19.18 01.19.18 1M1�9 REVIEWED FOR CODE COMPLIANCE APPROVED DEC 0 5 2018 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA NOV 2 9 2018 PERMIT CENTER IFC DESIGN SUBMITTAL 10.02.18 DETAILS CURIUM REVISION W5787963 s'°D`ORIG DAN 10.02.18 TD'E 11N7 LAB BUILDING 9-98.1 t M519 JOB NO. MULTIPOINT AIRFLOW SENSOR FLEX CONNECTION 24VAC FROM CONTROL TRANSFORMER (15VA PER CONTROLLER) INVENSYS MNB-V1 BACNET COMPATIBLE 0-24VAC DDC ELECTRONIC NIAGARA COMPATIBLE BACNET WIRING, DAISY CHAIN FROM NEAREST VAV ELECTRIC DAMPER SHAFT ACTUATOR NEW TSTAT CONTROL WIRING NOTES: 1. ALL EXISTING CONTROLS HARDWARE PROVIDED BY OWNER SINGLE DUCT TERMINAL UNIT WITH CONTROLLERS SCALE: NONE 11412 IA520 CONTROL WIRING FILTER NIPPLE DETAIL 1 CONNECTOR RF NUT RF GASKET SHIELD PLATE Alli 11111 1111111III I!I RF NUT FILTER BACKPLATE DRYWALL AND PLYWOOD BACKING ALL -THREAD NIPPLE ALL -THREAD NIPPLE OPTION AND LENGTH MUST BE SPECIFIED TO FILTER MANUFACTURER. BETTER TOO LONG RATHER THAN TOO SHORT. FILTER PART NUMBERS: * HVAC CONTROLS ANALOG DATA FILTER: GENISCO GF58270-10 INSIDE SECURE SPACE OUTSIDE SECURE SPACE 1 SEQUENCE OF OPERATIONS: EtLEBAL ROOM TEMPERATURE SETPOINTS SHALL BE 70 DEGREES F DURING THE HEALING SEASON AND 72 DEGREES F AND 50% RH DURING THE COOLING SEASON, UNLESS OTHERWISE NOTED. SINGLE DUCT TERMIANL UNIT START/STOP WHEN 1HE AHU IS ENABLED. THE DDC SYSTEM SHALL ALSO ENABLE THE TERMINAL UNITS SERVED BY THE AHU. EACH SPACE TEMPERATURE SENSOR SHALL RESET THE BOX DISCHARGE TEMPERATURE TO MAINTAIN THE INDIVIDUAL SPACE SET PONT. AS THE CALL FOR COOUNG INCREASES, THE DOC SYSTEM SHALL OPEN THE TERMINAL UNIT PRIMARY AIR DAMPER. AS THE CAU. FOR COOUNG DROPS, THE DOC SHALL CLOSE THE TERMINAL UNIT PRIMARY AIR DAMPER TO ITS MINIMUM SETTING. THE DDC SYSTEM SHALL ALARM FOR ZONE TEMPERATURES GREATER THAN 6 DEGREES ABOVE OR BELOW SETPONT FOR MORE THAN 15 MINUTES. THE DDC SYSTEM SHALL ALARM FOR ZONES THAT DON'T MEET MINIMUM AIRFLOWS FOR MORE THAN 15 MINUTES. SINGLE DUCT TERMINAL UNIT WITH EIEC HEAT START/STOP WHEN THE AHU IS ENABLED, THE DDC SYSTEM SHALL ALSO ENABLE THE TERMINAL UNITS SERVED BY THE AHU. EACH SPACE TEMPERATURE SENSOR SHALL RESET THE BOX DISCHARGE TEMPERATURE TO MAINTAIN THE INDIVIDUAL SPACE SET PONT. AS THE CALL FOR COOUNG INCREASES, THE DOC SYSTEM SHALL OPEN THE TERMINAL UNIT PRIMARY MR DAMPER. AS THE CALL FOR COOLING DROPS, THE DDC SHALL CLOSE THE TERMINAL UNIT PRIMARY AIR DAMPER. AS THE PRIMARY AIR DAMPER REACHES ITS MINIMUM SETTING AND THERE IS A CONTINUED DROP IN TEMPERATURE (A CALL FOR HEATING), THE DDC SYSTEM SHALL MODULATE TERMINAL UNIT PRIMARY AIR DAMPER TO A MINIMUM AND MODULATE THE TERMINAL ELECTRIC HEATING COIL SCR TO MAINTAIN THE SPACE TEMPERATURE SETPONT. THE DDC SYSTEM SHALL ALARM FOR ZONE TEMPERATURES GREATER THAN 6 DEGREES ABOVE CR BELOW SETPOINT FOR MORE THAN 15 MINUTES THE DDC SYSTEM SHALL ALARM FOR ZONES THAT DON'T MEET MINIMUM AIRFLOWS FOR MORE THAN 15 MINUTES. OFMAND CONTRO MENDLATION THE DDC SYSTEM SHALL MONITOR THE CO2 LEVEL IN THE CONFERENCE ROOM BY THE USE OF A CO2 SENSOR (SHOWN ON PLANS). UPON A RISE IN CO2 ABOVE A PREDETERMINED CONCENTRATION LEVEL 1000PPM (ADJUSTABLE -100 PPM DEADBAND), THE TERMINAL UNIT PRIMARY AIR DAMPER SHALL MODULATE TO INCREASE PRIMARY AIRFLOW FOR 5 MINUTES AFTER 5 MINUTES AND CO2 DROPS BELOW SETPONT, THE TERMINAL UNIT PRIMARY AIR DAMPER SHALL RETURN TO NORMAL OPERA1ON. THE DDC SYSTEM SHALL ALARM FOR CO2 CONCENTRATIONS GREATER THAN 1500PPM. 1! ICD ROOM WALL (SECTION V1EW) • 1/2" TO 3/4" PLYWOOD FOR FILTER MOUNTING, WAVEGUIDE SUPPORT, ETC. SIZE AND THICKNESS CAN VARY BASED ON WHAT IS MOUNTING ON OUTSIDE WALL f]LIE6S • MOUNT SIDE BY SIDE AND THE FOLLOWING 'ARE ANTICIPATED: - HVAC CONTROLS ANALOG DATA • FILTER NIPPLES ARE TYPICALLY 1" ALL THREAD - SPECIFY REQUIRED LENGTH WHEN ORDERING AS DEFAULT LENGTH OF 3" WILL BE TOO SHORT. • CONFIRM WITH ELECTRICAL DRAWINGS IF ADDITIONAL POWER IS REQUIRED. OTHER NOTES; • COORDINATE ALL PENETRATIONS WITH ARCHITECT • INSTALL PIPE PENETRATIONS IN DATA FILTER PENETRATION PLATE IN ORDER TO MINIMIZE THE NUMBER OF PLATES. • USE GALVANIZED RMC OR IMC CONDUIT. • USE RF SHIELD FOAM FOR ANY GAPS IN PLYWOOD PENETRATIONS. 705 HVAC CONTROL WIRING PENETRATION DETAIL SCALE: NONE 1M12 M520 DME 11N7 LAB 85787983 FSE 10.02.18 01_470E7/NW MULTIPOINT AIRFLOW SENSOR POINTS LIST: SYSTEM NAME: VAV BOX WITH ELEC HEAT DESCRIPTION• ANALOG Aw&oc OM,RAL Nam moms REMARK$ INPUTS OUTPUTS INPUTS OUTPUTS SPACE TEMPERATURE 1 1 DAMPER MODULATION 1 AIRFLOW (CFM) 1 1 HEATING COIL MODULATION 1 ASSUMES ONBOARD AIRFLOW PROVING SWITCH SYSTEM NAME: VAV BOX (PINCH BOX) DESCRIPTION; / OG ANALOG OCITAL oar& WRVS REMARKS INPUTS OUTPUTS INPUTS OUTPUTS SPACE TEMPERATURE 1 1 DAMPER MODULATION 1 AIRFLOW (CFM) 1 1 SYSTEM NAME: VAV WITH CO2 CONTROL I DESCRIPRION• t ANALOG 7 ANALOG Dam Op TN. was s REMARK INPUTS OUTPUTS INPUTS OUTPUTS SPACE TEMPERATURE 1 1 DAMPER MODULATION 1 AIRFLOW (CFM) 1 1 HEATING COIL MODULATION 1 ASSUMES ONBOARD AIRFLOW PROVING SWITCH CO2 CONCENTRATION 1 1 500 PPM TO 1000 PPM ELECTRIC REHEAT COIL FLEX CONNECTION 24VAC FROM CONTROL TRANSFORMER (15VA PER CONTROLLER) INVENSYS MNB-V1 BACNET COMPATIBLE 0-24VAC DDC ELECTRONIC NIAGARA COMPATIBLE BACNET WIRING, DAISY CHAIN FROM NEAREST VAV ELECTRIC DAMPER SHAFT ACTUATOR NEW TSTAT CONTROL WIRING NOTES: 1. ALL EXISTING CONTROLS HARDWARE PROVIDED BY OWNER SINGLE DUCT TERMINAL UNIT WITH ELECT HEAT SCALE NONE 1M10 hFSi consulting engineers Seattle, Washington Solutions & Service ACCEPTABIUTY 1IiS oslcl MO/OR SPECIFICATION 8 APPROVED APPROVED Sr DEPT. DATE DGK ITFOREO CLS 5.5 61E 01.19.18 01.19.18 IFC DESIGN SUBMITTAL 10.02.18 SEQUENCE OF OPERATIONS, POINTS LIST & DETAILS REVIEWED FOR CODE COMPLIANCE APPROVED DEC 0 5 2018 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA NOV 2 9 2018 PERMIT CENTER W5787963 snwORIG 10.02.18 CHECKED APPROVED 01.19.18 01.19.18 TITLE 11N7 LAB BUILDING 9-98.1 "CET M520 .ANO MATCH LINE -FOR CON -7-44.,i,.., SEE SHEET 1M1 MATCH LINE -FOR CON -1 SEE SHEET 1A13 8T DAN m SEE 1E13 1T7 -1/40b FIRST FLOOR LIGHTING PLAN M'.) SCALE: 1/8'= 1'-0• BT ONE A 9-98 RENOVATION 4 140799-00 OAR GROUP J. BECK 08.15.06 11N7 IAB W5787963 CASNE 10.02.18 B ASI 004 4 140799-00 OAR GROUP J. BECK 09.15.06 C ASI 010 4 140799-00 OAR GROUP J. BECK 10.20.06 O 12..n.,I/71_,,,.=e Her,,,n. , em, ne At SEE 1E13 117-1/40b BOE/AW RECEIVED CITY OF TUKWILA NOV 29 2018 PERMIT CENTER REMOVAL ACCEPTABILITY MES DESIGN AMD 08 SPE06 A110N 6 o r DEPT. DRAWN DATE 02.12.99 mem 101:DATE JJOHN J. VRIREK 02.12.99 KEY PLAN 101 LEGEND WITH DIM2 LAMP 2X4 RECESSED FLUORESCENT FIXTURE MING BALLAST. 2 LAMP 2X4 RECESSED FLUORESCENT FIXTURE WITH NON -DIMMING BALLAST. 2X4 RECESSED FIXTURE ON EMERGENCY CIRCUIT ▪ WITH NON—DIMMING BAUAST. ® 3 NSE OURESCENf FIXTURE WITH NON—DIMMING ®g2E1 2 LAMP, 1X4 FLUORESCENT FIXTURE, CEIUNG OR WALL MTD. 1X4 FIXTURE, CEIUNG OR WALL MTD. MIMI MIEN ON EMERGENCY CIRCUIT. ® 1 LAMP, UNDER CABINET FIXTURE. AK RECESSED DOWNUGHT WITH DIMMING BALLAST. tt RECESSED DOWNUGHT WITH NIA—DIMMING BALLAST. AA RECESSED WALLWASH WITH DIMMING BALLAST. • RECESSED DOWNUGHT ON EMERGENCY CIRCUIT WITH NON—DIMMING BALLAST. O PENDANT FIXTURE, 9'—O'AFF, UNO. • PENDANT FIXTURE ON EMERGENCY CIRCUIT. 440•Y PENDANT DECO FIXTURE 7'-10" AFF, UNO. • PENDANT DECO FIXTURE ON EMERGENCY CIRCUIT. LED EXIT SIGN ON EMERGENCY CIRCUIT, 9' -0 -AFF. FILLED IN AREA INDICATES FACES . ARROWS INIDCATE FACE CHEVRO ). WALL PACK $ LIGHT SWITCH, SINGLE POLE $3 UGHT SWITCH, 3 WAY $° UGHT SWITCH, DIMMER $°E WALL OCCUPANCY SENSOR/LIGHT SWITCH $� WITH NG CONTROL 6MU OVERRIDE SWITCH ZO® 480Y/277V LIGHTING PANEL ® PHOTOCELL ® CEILING OCCUPANCY SENSOR NL NIGHT UGHT TO REMAIN ON 24/7. NOTE: EMERG. FIXTS. WITHOUT NL' WILL STAY ON ONLY WITH LOSS OF NORMAL POUR. OTHEWISE THEY WILL SWITCH OFF WITH AREA UGHTS. FIXTURE IDENTIFICATION "X" DENOTES FIXTURE TYPE. 'Y' DENOTES TOTAL FIXTURE WATTAGE. GENERAL NOTES 1. DYMO LABEL EACH RECEPTACLE, JUNCTION/OUTLET BOX AND SWITCH WITH CIRCUIT IDENTIFICATION. 2. POST NEW OR REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. 3. RETURN REDUNE MARKUP DRAWINGS TO ENGINEERING UPON COMPLETION OF JOB. [i CIRCUIT UGHT FIXTURES THROUGH PHOTOCELL SHOWN AT EAST EXTERIOR ENTRY, SHEET 1E13. • 0 0 0 0 ME: NONE 8' 4' 0 4' 8' 1Dq =1' ISSUED alattir ION ARARov FJ* PLA 16' REFERENCE DRAWINGS REMOVAL NOTES DISCONNECT AND REMOVE UGHT FIXTURE. REMOVE CONDUIT AND CONDUCTORS BACK TO NEAREST JUNCTION POINT. • DISCONNECT AND REMOVE UGHT FIXTURE COMPONENTS TO PREPARE FOR RETROFIT KIT TO BE INSTALLED. • PREPARE UGHT FIXTURES TO BE CONTROLLED BY NEW UNE VOLTAGE SWITCH ON SAME POWER CIRCUIT. DISCONNECT AND REMOVE CONDUIT AND CONDUCTORS. PREPARE TO WIRE FIXTURE TO NEW CIRCUIT. CCASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10804 ME .YD PL. SLUE 203 NPoOAIQ W1 BMW (425) 572-1000 8W06C494E0211 JOB MES 181-904 CURRENT REVISION W5787963 SYIBBL E oA 10.02.18 11N7 LAB BUILDING 9-98.1 SHEET 1E12R JOB NO. .... ,... ,... ND. MATCH LINE -FOR CONT[t SEE SHEET 1A11 X3F7/8a XS3F7-1/11b STAND—BY ABQVE CEILING 6 SEE SHEET 1E61\ 3/4. 2112, 112GND k=i 1E7 -3/10b SEE SHEET 1E61 1a \J4 21 18 1T7-2/200 18 117-1/ 190,21b' 117-2/ 17c,190,211 f8 1T7-1/23c,25a,27b XS3F7- 11b /tz X12 /10 117-2/24c (017-2 2a 1T7 -2/32a 24c' ; 24c 32a ' '32a 32a Com TRI 7c'. a 4i17 -1/24c 117-2/22b,24c 117-1/ 7a,9b,1lc 0 LTG. SEE E-12 (2)20A, IP 3KVA,120V,1 1117-1/6 35e 1'7 86.08 CEIUNG 30e 20 Ia JA FILTER' 22b 117-1/ 26a,28b 110 13.1 ISO.TRANSF. 1R7-1/ 480-208Y/I 250.2713.29e PNL1R7-1 160,18b.20c P8/ 9a,b,c, 1 117-2/ 8a,10b,12c 1T7-1/ 20a,22b,24c 1T7-2/ 33b,35c 117-3/ 36c,38a,40b 8a,10b,12c MATCH LINE -FOR CONTITi. SEE SHEET 1A13 or /PANNED DAN 1T7-2/13a,15b17c XS3F7-1/11b STAND-BY +7' AFF 1T7-1/130,15b,17c SEE SHEET 1E63 to SEE SHEET 1E63 117-1/31a PLAN SCALE: 1/13. - 1'-0• APPROVED ONE 9-98 RENOVATION 4 140799-00 DLR GROUP J. BECK 08.15.06 NFD 815160934 916881N 981891N 05.31.17 8 9-98 REN0VA110N 4 140799-00 OUT GROUP J. BECK 0824.06 11N7 LAB 85787963 CASNE CEC 10.02.18 RECORD DRAWING 4140799-00 OLD CROUP J. BECK 07.23.07 117-2/ 34c,36a,38b to SEE SHEET 1E63 SEE SHEET 1E63 1T7-1/310 REMOVAL ACCEPTABILITY CHESTERFIELD x 0R C 10.09.92 1116 LESION810//OR aE� SPECIFICATION 6 APED BY DEPT. w0E ter moi. Pas 14. PriC13* AW R 1$ O ®2 AC LEGEND 15A, 125V, 1 PHASE, DUPLEX RECEPTACLE 20A. 125V, 1 PHASE DUPLEX RECEPTACLE 15A, 125V, 1 PHASE DUPLEX RECEPTACLE (DEDICATED) 15A, 125V, 1 PHASE DUPLEX RECEPTACLE (DEDICATED) WITH GROUND FAULT CIRCUIT INTERUPT 30A, 125V, 1 PHASE, TIISTLOCK RECEPTACLE 15A, 125V, 1 PHASE, 4—PLEX RECEPTACLE 15A, ISOLATED HGR01)ND 4—PLEX RECEPTACLE 15A, 125V, 1 PHASE, DUPLEX FLOORSTACK 15A, 125V, 1 PHASE, 4—PLEX FLOORSTACK POWER OR TELEPHONE OUTLET MOUNTED IN DOUBLE BOX MOUNTED IN FLOOR WITH ISOLATED GROUND. 15A, 125V, 1 PHASE, CEILING MOUNTED DUPLEX 30A, 208V, 1 PHASE RECEPTACLE SPLIT CHANNEL TELE/POWER POLE. DATA P011 SINGLE POLE TOGGLE SYATCH 120/208V DISTRIBUTION PANEL TRANSFORMER, CAPACITY, PHASE & VOLTAGE AS SHOWN DISCONNECT SWITCH, NON—FUSED, XX AMPERES EDWARDS /620 LV PUSHBUTTON//821 LV PUSHBUTTON EDWARDS /725 LV DIXIE BUZZER/I340A—N5 LV BUZZER MOTOR STARTER, MANUAL JUNCTION BOX, CEILING/WALL MTD. EQUIPMENT CONNECTION PUSHBUTTON (ADA) ABOVE COUNTER MOUNTED GENERAL NOTES CONNECTION FOR BADGE READER AND/OR ELECTRIC STRIKE/MAG LOCK. CONNECTION TO EMERGENCY PANEL X3F7 FOR DOOR OPERATOR AND HANDICAP DOOR SWITCHES. REFERENCE DRAWINGS REMOVAL NOTES I> DISCONNECT AND REMOVE SYsILMS FURNITURE POWER. REMOVE CONDUIT AND CONDUCTORS BACK TO NEAREST JUNCTION POINT. RECEPVED CITY OF TUKWILA NOV 2 9 2018 PERMIT CENTER ISSUED FO /:?,,,,,E:P44A,RArET SiAlth i • 1�i 4'"I•i 208Y/120 VOLT POW KEY PLAN SCALE: NONE 8' 4' 0 4' 8' 16' SCALE: 1/8'=1'-0' OVAL tIAAS CASNE ENGINEERING, INC. 10804 N 38th P TECHNOLOGY 2 aaY ELAN.. WAN O taxa AL D suit iLO YCO N0. NN NS pts) 572-t000 8881C.49lEC N1 J03 NQ 181-104 N W5 87963 F 1UCKER 10.09.92 APPRDIXED- 11N7 LAB BUILDING 9-98.1 SHEET Sntaal 1E62R 081E 10.02.18 J0x Na. ,,,�e COMP NO. STN LIGHTING FIXTURE SCHEDULE - INTERIOR Project Name: 902140 9-90 Project No: 73-07121-00 1X0 114. CA900 MOM 1117 NUN -RBE 490799 NA AN WE OW AT INN 1X0 R Of 97 NPN AOT 1444118 1X0 0290709 170 277 f 11 MN ne A A E 30 4- S R r OIl7, 090100 0084144 /1 01 WHAM MANN 0190 LEN NNW IDS 10613030E MR MOW 9-4190 22 P WHOM 443*90-051319 C % % 34 1495 OWN5 W. r waft WANK 1101-217, MOWN 964 117 WINO LL /Dam NP 10090 442 f 02 SW 30 TO E S S 0 5 r r WE Mt CNC LEIS VIS SCIS® TO 900 WN 00 AT 01512 MENU 61.012 WNW WIT ANNA CON 4494 0E 190 91071; 191400E 122!1730 400144 927 NV AI/SR LL IAN 10(124 1941-41 101® 93 E 3 NO NC A 0 7 1 90 AT 344 4411 S 4' luau soma 440 18 NOME 904&704 00 Houma 99 WA AWL FRAC 4404904 9100 LL INN IN) HICK 2.3 R r 000 DILL 0191 venue IS 0L WEAN NNUNN 90 MOW 2.3 00 1011244 931000.913101-011 0 X X 34 049141090E 1198 POOW 91-4111111914 F 1 50 30 180 OP91 5 RN. r MEA19e 194190. 1224.270 190 90 IN OWN LL LIMED 94 100.0E fit 410 0( 909 91 TO OCC SWAM 14x' MOOR UN* VIP; 110010 WNW WNW INN OUNINII R 00 A L3 f 1 329 12!0 31 4-411 1 0 0 24 R r I[I® AOR. 50*! 1913105. WINO 494044 we MIN 0 FEN 10010040' 744819 SOf- FINN NM NPN 55/9'. r mama ANON 164-2te4 710812 90! IR NWO LL 1840 INT 10000E 2.3 1101001101 5441101-813101 371 441 A E 0 0 1 4' WH 1209 WU NAND 015!/1961 MET TOE WOE BOOR r NN 000 909 446 900 WIX AIR 6904' 4412 1106 09 1100 WC MUM 0410111104162015011 09 900 9044 N9 OLX WE AMC 5097900 1775NUM IL V09 23 05 0110151100201770 f 2 30 Of 344 4-10 C 9 2 0 R r 3499 900E ORO 991E 10100 0044441 ON 09000017 OWNED PIBOC 0070 1.015, 0/32' X12(10099 44190 441-02012 MAW 401691110 AN 111 7409000 OEM (10L NNW 501-11/110622 0. 084094 4709 90 12118410 RIMS 11901.890-17749040! IR 441N0 LL 1012 ET LOOM y 401444 1211.0.07-0024714 301 1ST 30 4-111 5 All NOR NOW NL NOON 11' NSA }DIC MUM 322 0-010 NW. MA INA; FOAM 0050 WE MONO 610511.1044041E LEN 45897 IN 1000110W661090 M SW 444E 2.3 S0 ONO 1001-00* E 1 30 144 30 4-411 12 WAR RS NAM 7449 RENON NLA; LL ISS R 4 1/' 19412 844E OLT 991E WEN 94(00 9441 MONO ONION NAM= 40/0 WH 1/4.111201-1 PM NAN 90-8260606190434 2.3 440 90114410 408400-4041440137 E f 0 34 90*6101 TO AM 19 9010 CDR MNL 444044 S OWN NINE 5 4' 9911E 400E YOM (090 691 /001W (9N0 WS NN 0189 12 IAN N0 WNW NI6f WM 8694 PURL LL INN FOR NIP 101O6 9f-1190 m 9 VANN FOND SOL WAND 01116 PON 449: 111 100-8 740 NEST, it 1012 ET 40(00 410372784 7 1 341 1111 38 4-411 R 4 (/'r WM SONE NIL 00 SANE WON 011.10110 WN 090017 COATED WNW 400 WM 5/32.11111111061343) CAN 914909 010441. MEAN 14'401A INESA0 ODA INN NIO 7 07 (01!09 4X1000-12130013 E X 34 NL ANN soma mom W ono PoufN4MIT9 -.100116(06.19 but fart 907Q 11:0100L 011E MIRED O NT AWOL LL INN MINA NLA 91 MIA 2121/4. 044-IbgO 414V1i0 22 0. NACU RNA 006 WNW FINN PON SIN 111 100-31 WOO WON LL IMM ET 1040L 40 A 1 1 111E 0110011L0 8427 Y 9 11 r ON N1910914N REFLECTOR 001111010, r NOME; 4041000 99697110 9141/190 00844 00009 1140 70007; 06106 1221449100445 4440 1114[-41 0 2 3/4:0 1/0 LL 1.412 057 IL0001 2 100014 01010-30111110 5 r 0691E 4 040044 WON OWN OW. WE NOPA PRAM 11311 90-000 400 ND WO 9 410E 51M 4064; mama 010 090; 78 444099014 101 FWIO0! F161NM 070 WNW IMAM LL VELEM 7.3 W 1119 41 E 1 I 1 NII 1110 R 1 _ 7 23 R 3 3//4' ILA® 11L1. AIA RMED 4340 140 401A L 33/4- MERIIN OWE 9119 P1104PAOLO 1401004 4411 91200( 961910 *646490 4010128 415041 W 2 3/x%10 I/0 LL 100 AP 100001 2 440109 37770-310444% 1444 LEN N0 W 0 X X 0 120E 044 IN IN TSR 9OE TWE( 991-11 ESN IDIOM MOS LLAMA A MEET INA 101, 122/21'7644 OR MUNE 9114 LL IMOD 1 AIRC 1 011354 7 4 m 30 30 4444 P900f 11* OR 069 11611 NW 030444070 W541901191.10. 2' 10A 9a( WN W 112 OCE RN= ALUMNA PONT 190 WAN 8/ WAWA 0310 TWA 110163 ON CASS RO NOW R1 )101444 X _ 41100 1 Y Y IN 10016/ UMW 049 404.120 044 3I.• am. XNR WON MIL 4449 4144 310 MENA WNW 110-0075 00991 PINNY 90 IR OWN LL 100 3 60 MI NO 1 2 PENN® 3401 POO. 1501 MEM OICP71 /4019163.4499414412361 690931 MIN. 1/ W 004 MOPE 6 DEIN= 901 9140E AN 42 LANA 1144144-I00711f 1 Y % in SPAS /0 12 4YI 15 ONES MR -X8406194 P BOOOIIe E X X 40 NAT WILL STEEL ONO WNW. 944040 1N441M917 WE 009 MO= 0419% 0110011. 110-225 PT09N 904 IE *INP LL IDN. 1I -4a imam Ammo TIN 109. ova ORT 9000 1 90 1111[ W 4-111 194414 x441 OHO 156 AWL 7041 OWI F905 PRESSED 121E COOED 0111 AN 2.3 !n WOMB 404710-40011-400-4050Ff % x ]S 084 *NII 044 12: 0 6 0 4 41671 4124 0 W. ONE 0 ONE WARM WM OND AO( ONO 000 010 0441231 (901-42111004 504 961 90190LL INN. tV019,I19N0 71 W 127 390 4.111 POHIO T DR OLD INN 41 0A WO DINIEAS. 409 ND OE1 VON FOOS W1O NW 109 1204 WOAD 604 ! 09 NN NN NSR OE 09 04011124 vir 1112 0 06 WN 2.3 PP MAN 00-001 7 Y x 3S ' PW 1ONON1 N1.20 311411* 1017 NO 4840044 SA$ WART 0R 018410E 13-914 MOW 911! NV SIGN IL 109E 115 194411444 IWi-ROI f 1 130 ]AfE 4-41 % IS 744012! 23/5' OIL OLD PEN. 41 OW MO 0049 01019 011444484 124900 110 ODA IAA RNA 1813 114 1440 OPS, MAW NW 225 0161104 WON LL 101616 2.3 7 2 A 10 W 4.411 FNMA 449 1001! MN SIRES IOW 0016141111 MINN 11 EL NOAH NOVO 40160! WARM OWN ANNA 003014 LL ICED. 2.3 PO 1319441 EtlWM1C- EMIL. A NEI WA E X X 0 f 1 111 10 440 4.611 INCA. 12. OA ® PEED. NATO WOO EDAWNW IN SAWED 0INIOR 111 90 A R ON FLOWN RIN1 ISO IONS 6/ 1.3 P37 LOMA 007409-1093-01220-4100 0 X X O 40010E NW XOE 0114 O NILO FOR NOW 69040/ LEN910 11.4 ANNA W( 110 5427 906 0100 ARO! MIM 849 OEM 60 001012E ORAN 441-274 PROWS SSW NV SWAN UL 122E 1011 RANSOM 00/00E96 NNW f1 WI 727 440 4-411 704414 If 1199 PON 009 0014000 TINA 414019 90NN 0111-901 LONA 447161014 SWAN LONER 1.01/41100101111011-100110 41 144404 0401100,54 L 0 1111 MORN 6099. swam237 OA RUN 44984 W11 00; Cf NUM WIT N9NOEL 004 POO 4N C0 MT LL NM E 5 m AI A R 0 2'. 1 90 1010/101182 90 TA RNA r 903! PAWN) 1891 IAP NWD WN IMM MND WAS P 44001 0SYR2A-494M E X X 0 I NES 009 1110 NO *ILA 9091011! 924118E ROI RON 5176 NW RN NA 901144 01201004 NOMA1201-2314 MOW 901! 19I 9010 LL IOM 2710 F1 30 90 Al 1 X CO R 0 r . 4' I® OFCf/NO91 WNT ME MOOR r DOR -401212 NMI WP NIO NO AN AMC ONLN WOES 81011 ERIN0 44OWN 001774114x1901 441 WN NM 99 80011 M10144 /1010/94 4180-10 WAX N 0 NAG SWAN LL 90 2' 01109 092902239-0-/02 W 6 NO OMC INA f2 30 SO A R a 2' . 4' WEI.O O NNW! NON AL FINN IT 04.. 12440 R0 MIN ONO ON*0RON 106 OVA 90 MN u R IMAM 160107013-227-447 E % 94 0110111011111/0044744! 40184E 64 MOM WAC *INT NN RPI WE NNW NNW. ONO 3 W 061444 441140 NOMe LL WIN 2 09 320 A R a r 4 R 063- M 69 0114490 RAIN T OW 09 RIMY WE ORIF 4X4110 WAN MEOW SUAA 901101190100 41104 114404 WC 119 NAT ICE AMC AN. 1105111 X-041 2/3 113 99000 001140 341247-15-0F E x 110 PO= OWN NEAT L 9/4 M '4 R 0 r. r 11104E IN ONO0 AIMS r.1 WSW 11190441120704 129E-4IfUNE ASCE WM0-10NAM (203114 W 90N (44(108444* 0 0 M 495 WAN 134/07 IN 0. OO F.190-0114 viva 4461(10 97 *MORD 000 STM 0503 9-90 RENWA110N J1150680-01 D(R CROUP J. BEC( 04.26.07 A 9-90 RENOJAIION DC42 4150660-01 lift CROUP J. BECK 06.08.07 B 9-90 REND/PAM DCN/3 J#150660-01 MR GROUP J. BECK 06.08.07 UGHTING FIXTURE SCHEDULE - INTERIOR Project Nam* MC 9-90 Project No: 73-07121-00 194 CONN 189ER VIP INA ROOF 193012001 NA 16E 4f Nor OW ME E W IDU EPS[ AOT M1116 1X0 04071109 WE OWN 179 277 f 1 MN ne A S r 901094E SNP 111041611205 090 NW 1105 RENOIR OWN W 0900 LL IOM 2.3 101. ANNA 048232-0-19- m19 O E S 44 442 f 7 SW 30 TO E S S 0 5 r r WE Mt CNC LEIS VIS SCIS® TO 900 WN 00 AT 01512 MENU 61.012 WNW WIT ANNA CON 4494 0E 190 91071; 191400E 122!1730 400144 927 NV AI/SR LL IAN 10(124 1941-41 93 E 3 NO NC A 0 E 0 S 4' luau soma 440 18 NOME 904&704 00 Houma 99 WA AWL FRAC 4404904 9100 LL INN IN) HICK 2.3 ISN 74144-22-41-60940 F 1 50 30 180 fit 410 0( 909 1194 800. ROOD TO OCC SWAM 14x' MOOR UN* VIP; 110010 WNW WNW INN OUNINII R 00 A L3 844 110111414 0414484E 1 X • WELEC109 M0 MAMIE 1010 1 Ma 940 508118 901044 444160LL 12200. OS 7 2 371 441 A E 0 0 1 4' WH 1209 WU NAND 015!/1961 MET TOE WOE BOOR r NN 000 909 446 900 WIX AIR 6904' 4412 1106 09 1100 WC MUM 0410111104162015011 09 900 9044 N9 OLX WE AMC 5097900 1775NUM IL V09 23 (44*1N 0110151100201770 T 1 301 1ST 30 4-111 5 All NOR NOW NL NOON 11' NSA }DIC MUM 322 0-010 NW. MA INA; FOAM 0050 WE MONO 610511.1044041E LEN 45897 IN 1000110W661090 M SW 444E 2.3 S0 ONO 1001-00* E 2 12 WAR RS NAM 7449 RENON NLA; LL ISS 307 f 1 NW 30 n E S 0 5 4' 9911E 400E YOM (090 691 /001W (9N0 WS NN 0189 12 IAN N0 WNW NI6f WM 8694 PURL LL INN FOR NIP 101O6 1101400 410372784 7 2 40 01001 5 NL ANN soma mom W ono PoufN4MIT9 -.100116(06.19 but fart 907Q 11:0100L 011E MIRED O NT AWOL LL INN 2.3 91 MIA 2121/4. 044-IbgO X 40 7 1 20 300 15 5 r 0691E 4 040044 WON OWN OW. WE NOPA PRAM 11311 90-000 400 ND WO 9 410E 51M 4064; mama 010 090; 78 444099014 101 FWIO0! F161NM 070 WNW IMAM LL VELEM 7.3 W 1119 721 E 1 24 0 1. 1444 LEN N0 W 0 X X 0 120E 044 IN IN TSR 9OE TWE( 991-11 ESN IDIOM MOS LLAMA A MEET INA 101, 122/21'7644 OR MUNE 9114 LL IMOD 1 AIRC 1 011354 72 L 10A 9a( WN W 0 % X a. 940 00 410. 0 00, WPM 9440 EEE -427 0081 WAR 101146 110110110 A 1417 WM 14. 114%277/14 44111E 1001E NUE LL 1441® LANA 00991 1 2 1018 WN Leer 0 I 001 I (01''. I NOMA 0 22 0 OLAND AM SOWN RAH TAN N0 WI NN 9 IWO 9040111 611.10011011N COMO OR NW SRI lESTIPM/SEIF 0900184$ 70/47704 ARD 800 011010 CS MOW9 1040 AIL INN 2 0 12114. 11 SWAM MAP E X X 40 0;LAMEAVAW ABBREVIATIONS I: INCANDESCENT F: FLUORESCENT MH: METAL HALIDE L LED(UGHT EMITTING DIODE) HPS: HIGH PRESSURE SODIUM E: ELECTRONIC HIGH FREQUENCY BALLAST OT: OTHER(REFER TO FIXTURE DESCRIPTION P: PENDANT MT: MOUNTING CL CEIUNG S: SURFACE R: RECESSED W: WALL G: GRID PL PLASTER/DRYWALL EX: EXPOSED GENERAL NOTES 1. FLUORESCENT LAMP BALLAST ARE ELECTRONIC, ENERGY EFFICIENT, HIGH POWER FACTOR, WITH MINIMUM OPERATIONG FREQUENCY OF 20,000 HZ. MAN MTE 5. AVERY 0312.06 J. BECK 03.12.06 /672667711 ISSUED FOR LIGHTING 122E 11N7 LAB R1JtI nINr 9-90 RECEIVED CITY OF TUKWILA NOV 2 9 2018 PERMIT CENTER litfNT 4014101 W5787963 CASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10804 AE 312 PL. 087E 205 007374 0 00031 (425) 522-1000 OeleCASREGm J08 119 181-104 91190L C are 10.02.18 EO 3015 00. COMP 10. SECONDARY TIE TO SUBSTATION 26 t d9KVA 480-208/120V 10, 3W TO 9-98 EAST PENTHOUSE TO 9-90 EAST PENTHOUSE 1 CB 7.5KVA g g gAigg 240/120V9 r FAVNOW 10, 3W 1( 3 1/24. 4 126030 217-6 480Y/277V 125A MLO 14KAIC LIGHTING PANEL ELEC. ROOM 2176 117-5 480Y/277V 125A MLO 14KAIC IJGHTINC PANEL ELEC. ROOM 1156 m 121 3 1/2".4 1200 COOL EA. PNL P8 / 480Y/277V 800A MLO 22KAIC \11/!i.4R 126 `1 1/4% 3 p, 120 11/4Y. 712.16 BLDG 9-98.3 EAST PENTHOUSE 1000KVA - 13KV 277/480V XFMR I. MAIN / AKR-9D-50NM GENERAL ELECTRIC ITIEG p� IF2 qK F3g K In IFN `6bE=3OSR 16D_ E-30SR 16DE SR)800AF 6bE R OOA�T I• ql Q1-�,,,'-� T T .T P8-1 11/4'.712 758VA 480-208Y/120V a30 49 .t 1 T40-1- 217-2 208Y/120V 200A MCB 10KAIC ISOLATED GND PANEL ELEC. ROOM 21T6 751NA 480-206Y/120V MI''1r1 30 4W t 1 217-4 208Y/120V 200A MCB 10KAIC L,•G,4 & 11106 GND ISOLATED GND PANEL ELEC. ROOM 21T6 75KVA 480-2081/120V 148:8 -1 -ET i�1 30 4W a 1 114 117-2 208Y/120V 200A MCB 10KAIC ISOLATED GND PANEL ELEC. ROOM 11S6 APP110,m TATE 75KVA LA -"-A-1 480-208Y/120V "VW -1 30 49 t 117-4 208Y/120V 200A MCB 10KAIC ISOLATED GND PANEL ELEC. ROOM 1 S6 100A FILTER! 2S6 208Y/120V 30,4W 100A MLO 10KAIC I]NC0 LAB A 9-98 RENOVATION JO 140799-00 DLR GROUP J. BECK 08.15.06 RECORD DRAWING J1140799-00 OUT GROUP J. BECK 07.23.07 B NCO SIF RELOCATION - RECORD SET 1844093 WH ACAS 05.09.14 8 R. A B C_ D_ E_ F_ G H_ I_ J_ K_ L 1 2 EF -2 EF -3 R-13 AHU-1 AHU-2 NCO UPS NCO AC • R-14 VAV < 0 VAV < MC -7 SECTION 1 INCOMMING LINE R-13 20/3 CB VFD SIZE 1 7.5 HP R-14 20/3 CB VFD SIZE 1 7.5 HP SECTION 2 EF -2 15/3 CB/SIZE 1 COMB STARTER/DISC. 1.5 HP EF -3 15/3 CB/SIZE 1 COMB STARTER/DISC. 3/4 HP AHU-1 200/3 CB AHU-2 125/3 CB NCO UPS 100/3 CB NCO AC 100/3 CB A •7 :• B 3kW VAV (P/8) 20 3 CB 7.5kW VAV R/8 20/3 CB NOTES: 1. COMB. STARTER/DISCS WITH HOA, CPT AND RED PILOT. O1 CN. 4 P501131 Yar08* RLL 901 MOTE SUBSTATION AT 00100 Y. 7 pmm9. RH 112.5KVA 480-208Y/120V 39, 4W 3 4 p00fO9. 377 11/4412 JB 3 1/Y0. 4 imam. FA 11/4 412 gg 4[ 0 PNL R12 208Y/120V 400A MLO 22KAIC 1-1/4 4 #34/4 217-1 208Y/120V 225A MLO 10KAIC 217-3 208Y/120V 225A MLO 10KAIC 217-5 208Y/120V 225A MLO 10KAIC NORMAL POWER PANELS ELEC. ROOM 2176 117-1 208Y/120V 225A MLO 1OKAIC 117-3 208Y/120V 225A MLO 10KAIC NORMAL POWER PANELS ELEC. ROOM 1156 BOE/NO' ACCEPTABILITY TNS DESIGN 9.110/011 SPECIFICATION IS ANNOYED DEPT. DMZ TAM DRC alEEXED MOTOR CONTROL CENTER MC -7 PENTHOUSE 2nd FLOOR 10.90 1st FLOOR ISSUED FO co 1&3 ar EAST PENTHOUS _, r ' GRA LEGEND DRAW CUT AIR BREAKER. FILTER POWER FILTER LPRX-4X100A GENERAL NOTES j. PANEL 1R7-1, 45KVA TRANSFORMER AND FILTER LOCATED IN SCIF AREA NEAR COLUMN 6.2R ON SHEET 1E62. RT 10.90 RICHARD TUCKER 10.90 TIRE SUBSTATION # 11N7 LAB BUILDING 9-98 REFERENCE DRAWINGS E> 9-98.2-2E62 CONSTRUCTION NOTES PROVIDE AND INSTALL 20A/3P CIRCUIT BREAKER IN SPACE AS SHOWN. PROVIDE CONDUIT, CONDUCTORS, AND ALL ANCILLARY HARDWARE TO DISCONNECT SWITCHES ON FIRST FLOOR. SEE SHEET 9-98-1E112. RECEIVED CITY OF TUKWILA NOV 2 9 2018 PERMIT CENTER CASNE ENGINEERING, INC. ELECTR/CAL AND TECHNOLOGY CONSULTANTS 10904 AE 7B91 PL. 714/E 200 10111(LAN2 914 98637 (425)522-1000 9919CA*CaW JTW NO. 191-104 REVISION W5787963 sneer C 941E 10.02.18 SHEET E4 JOB N0. COMP NO. • f. 1 1 STY x DUE sv PARTIAL 1ST FLOOR GROUNDING PLAN SCALE: 1/8•= 1'-0• 11N7 1A8 W5787963 CASNE 10.02.18 ce;LIFO'El'ArG• � ISSUED FO PA GROUND LEGEND GENERAL NOTES REFERENCE DRAWINGS CONSTRUCTION NOTES PROVIDE AND INSTALL 18 CU GROUNDING CONDUCTOR FOR ENCRYPTOR. CONNECT GROUNDING CONDUCTOR TO EXISTING GROUND SYSTEM. RECEIVED CITY OF TUKWILA NOV 2 9 2018 PERMIT CENTER OV. T"IX 11N7 LAB BUILDING 9-98.1 1E9A 1E98 KEY PLAN O MU: NCE 8' 4' 0 4' 8' 16' SCALE: 1/8•=1'—O' fENT IKL140N 511100E W5787963 — CASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10/04 IE Nth PL. SUE 703 188UM 64 960133 (425) 522-1000 8N4o19E001I Jae Na 191-101 MEET 1E9C DATE 10.02.18 J08 N0. COP N0. X3T7/6c X3T7/6c (•) N N ; N `•� �•� e•' �•� (TYP.) TYP.), , 1: 1: c1 H1 H H iV 1a 1: H 11 H H S E tE13 ly PPROTED DOE STAT SEE 1E13 SEE 1E13 1T7 -1/40b SEE 1E13 (TYP.) FIRST FLOOR LIGHTING PLAN SCALE 1/8"= 1'-0" DAR A 9-98 RENOVATION 4 140799-00 OIR GROUP J. 8ECK 08.15.06 1161 LA8 W5787963 CAW 10.02.18 8 ASI 004 4 140799-00 DLR GROUP J. BECK 09.15.06 C ASI 010 4 140799-00 MR GROUP J. BECK 10.20.06 101 ft. S E 1E13 SEE 1E13-' SEE 1E13 1T7 -1/40b BOE/A/G• SEE 1E13 RECEIVED CITY OF TUKWILA NOV 2 9 2018 PERMIT CENTER 8' 4' 0 4' 8' 16' SCALE: 1/8'=1'-0' 0110TT EMMEN ,' JOHNER J. VAVREX LEGEND I=1 LED RETRO- It 2X4 FIXTURE SAMJIN}' FRK6EA-04535 BE 101 0 NL WITH DIMMING RECESSED FLUORESCENT FIXTURE 2 WAP 2X4 RECESSED FLUORESCENT FIXTURE WITH NON -DIMMING BALLAST. 2X4 RECESSED FIXTURE ON EMERGENCY CIRCUIT WITH NON -DIMMING BALLAST. 3 LAMP 2X4 RECESSED FLOURESCENT FIXTURE WITH NON -DIMMING BALLAST. 2 LAMP, 1X4 FLUORESCENT FIXTURE, CEILING OR WALL MTD. 1X4 FIXTURE, CEILING OR WALL MTD. ON EMERGENCY CIRCUIT. 1 LAMP, UNDER CABINET FIXTURE. RECESSED OOWNLIGHT WITH DIMMING BALLAST. RECESSED DOWNUGHT WITH NON -DIMMING BALLAST. RECESSED WALLWASH WITH DIMMING BALLAST. RECESSED DOWNLIGHT ON EMERGENCY CIRCUIT WITH NON -DIMMING BALLAST. PENDANT FIXTURE, 9'-0"AFF, UNO. PENDANT FIXTURE ON EMERGENCY CIRCUIT. PENDANT DECO FIXTURE 7'-10" AFF, UNO. PENDANT DECO FIXTURE ON EMERGENCY CIRCUIT. LED EXIT SIGN ON EMERGENCY IRCUIT, 9'-O'AFF. FILLED IN AREA INDICATES FACES . ARROWS INIDCATE FACE CHEVRO (S). WALL PACK LIGHT SWITCH, SINGLE POLE LIGHT SWITCH, 3 WAY LIGHT SWITCH, DIMMER WALL OCCUPANCY SENSOR/UGHT SWITCH UGHTING CONTROL OVERRIDE SWITCH WITH ZONE NUMBER. 480Y/277V LIGHTING PANEL PHOTOCELL CEILING OCCUPANCY SENSOR NIGHT LIGHT TO REMAIN ON 24/7. NOTE: EMERG. FIXTS. WITHOUT NL' WILL STAY ON ONLY WITH LOSS OF NORMAL POUR. OTHEWISE THEY WILL SWITCH OFF WITH AREA UGHTS. FIXTURE IDENTIFICATION "X" DENOTES FIXTURE TYPE. Y" DENOTES TOTAL FIXTURE WATTAGE. GENERAL NOTES 1. DY1.40 LABEL EACH RECEPTACLE, JUNCTION/OUTLET BOX ANO SWITCH WITH CIRCUIT IDENTIFICATION. 2. POST NEW OR REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. 3. RETURN REDUNE MARKUP DRAWINGS TO ENGINEERING UPON COMPLETION OF JOB. L CIRCUIT LIGHT FIXTURES THROUGH PHOTOCELL SHOWN AT EAST EXTERIOR ENTRY, SHEET 1E13. REFERENCE DRAWINGS 09-090-E0 UGHTING FIXTURE SCHEDULE O 0 0 0 0 �Le � ISSUED FOR CI "' ,i 10.0, :lbs CONSTRUCTION NOTES 11> PROVIDE AND INSTALL LED RETROFIT KIT IN EXISTING FIXTURE. PROVIDE AND INSTALL CONDUIT, CONDUCTORS, AND AU. ANCILLARY HARDWARE. © PROVIDE AND INSTALL UNE VOLTAGE WALL SWITCH. WIRE SWITCH TO CONTROL THE (5) FIXTURES IN OPEN SPACE ON WEST SIDE OF NEW WALL ® THIS LIGHT TO BE CONTROLLED BY NEW UNE VOLTAGE SWITCH. © WIRE FIXTURE TO EXISTING EMERGENCY CIRCUIT. PROVIDE CONDUIT, CONDUCTORS, AND ALL ANCILLARY HARDWARE. FIRST FL00 02.12.99 TITLE 11N7 LAB BUILDING 9-98.1 #25) ASNE ENGINEERING, INC. ECTRICAL AND TECHNOLOGY CONSULTANTS 04 NE .)!1a PL.. 921E 205 1060.067. M /EOl= 522-1000 MIILCAfNE.0011 JS NO 151-W4 81180E W5787963 REW810N E 1E12 DATE 10.02.18 COMP N0. XS3F7-1/11b STAND-BY ABQVE CEIUNG i SEE SHEET 1E61 3/4. 2/12. M12GND 1E7-3/1Ob SEE SHEET 1E61 11c 11T7-1/ 30c,32a,34b d1 XS3F7-1/11b STAND-BY ABOVE CEILING f8 1T7 -2/20a 1T7-21 1 a,3b,5c /8; 7-1/ 1a,3b,5c 01T7-2A30c iib 19a,21b 1T7-2/ 17c,190,21b18 16 1T7- /23b,25o,27b 2a 117-2/32a 117-2/320 1T7 -2/24c (18 1T7-2/', -20,4b,6c 1.17-1/24c c 0 LTG. ,�'.SEE E-12 (2)20A,IP IR7-I/6 3KVA,120V,I 1T7-2/22b,24c N1 110 1T7-2/ 7a,9b 11 110 1T7-1/ 7a,9b,11 c x~110 117-1/ 8a,10b,12c %10-r 117-2/ 8a,10b,12c 13a' IR7-i/32840b 3/4'C,4/12,/12G 1R7 -1/38a< 1 R7-1/33b,28b,36eQ 3/4'C,4110,2/ 12,/ 10G L 16aPN,18b,1R7-12. 20a,22b,24c 1T7-2/ 33b,35c 117-3/ 36c,38a,40b 1a 1T7-2/130,15b17c STAND-BY +7 AFF 1T7-1/13a,15b,17 SEE SHEET 1E63 IR7-1/2a,4b,31a 4j 1R7 -1/34b 3/4*C.6%10,110G 3/4'C,2112412G. EQUIPMENT SCHEDULE ITEM DESCRIPTION VOLTAGE HP KW REMARKS 1 MILL 120V - - - 2 LVP 120V - 1.04 - 3 THERMAL FORCING UNIT 120V - - - 4 ENVIRONMENTAL CHAMBER 120V - - - sr EPROM DOE 208Y/120 VOLT POWER PLAN SCALE: 1/r= 1'-0" m 011E 9-98 RENOVATION J/ 140799-00 DLR GROUP J. BECK 06.15.08 E IED W5160934 SHERWIN SHERWIN 05.31.17 9-98 RENOVATION 4 140799-00 MR CROUP J. BBI( 0624.06 11N7 IAB W5787983 CASNE CEC 10.02.18 RECORD DRAWING J/140799-00 OUR GROUP J. BECK 07.23.07 SEE SHEET .1 663 ,117-1/31a ce;LinstevArc• -- 1T7-2/ 34c,36a,38b 31a SEE SHEET 1E63 SEE SHEET 1E63 ACCEPTABILITY CHESTERFIELD ERFIELD 10.09.92 R46 0EM AND SPEC icAnoN 6 01 DEPT. OA1E 15'0 LEGEND IQ 15A, 125V, 1 PHASE, DUPLEX RECEPTACLE teL, 20A, 125V, 1 PHASE DUPLEX RECEPTACLE pa 15A, 125V, 1 PHASE DUPLEX RECEPTACLE (DEDICATED) IQ 15A, 125V, 1 PHASE DUPLEX RECEPTACLE (DEDICATED) WITH GROUND FAULT CIRCUIT INIERUPT If2t 30A, 125V, 1 PHASE, TWISTLOCK RECEPTACLE 15A, 125V, 1 PHASE, 4-PLEX RECEPTACLE WITH ISSOLATED TND PLD( RECEPTACLE $ 15A, 125V, 1 PHASE, DUPLEX FLOORSTACK > 15A, 125V, 1 PHASE, 4-PLEX FLOORSTACK POKER OR TELEPHONE OUTLET MOUNTED IN DOUBLE BOX MOUNTED IN FLOOR WITH ISOLATED GROUND. 15A, 125V, 1 PHASE, CDLING MOUNTED DUPLEX 30A, 208V, 1 PHASE RECEPTACLE 15A, 240V, 1 PHASE RECEPTACLE kei A ..QI m2 ED AC SPLIT CHANNEL TELE/POWER POLE. DATA POLE SINGLE POLE TOGGLE SWITCH 120/208V DISTRIBUTION PANEL TRANSFORMER, CAPACITY, PHASE & VOLTAGE AS SHOWN DISCONNECT SWITCH, NON-FUSED, XX AMPERES EDWARDS 1620 LV PUSHBUTTON!/1821 LV PUSHBUTTON EDWARDS /725 LV DIXIE BUZZER//340A-N5 LV BUZZER MOTOR STARTER, MANUAL JUNCTION BOX, CEILING/WALL MTD. EQUIPMENT CONNECTION PUSHBUTTON (ADA) ABOVE COUNTER MOUNTED GENERAL NOTES I] CONNECTION FOR BADGE READER AND/OR ELECTRIC STRIKE/MAG LOCK. 2' CONNECTION TO EMERGENCY PANEL X3F7 FOR DOOR OPERATOR AND HANDICAP DOOR SWITCHES. REFERENCE DRAWINGS CONSTRUCTION NOTES PROVIDE AND INSTALL CONDUIT, CONDUCTORS, AND ALL ANCILLARY HARDWARE © PROVIDE AND INSTALL 204 DEDICATED RECEPTACLE IN LOCATION AS SHOWN. © PROVIDE AND INSTALL 30A DEDICATED RECEPTACLE IN LOCATION AS SHOWN. PROVIDE AND INSTALL NEW CIRCUIT BREAKERS AS NEEDED FOR NEW CIRCUIDNG. SEE PANEL SCHEDULE. © PROVIDE AND INSTALL NEMA 1, 100VA, 120V-24VAC, CONTROL POWER TRANSFORMER FOR HVAC CONTROLS. MOUNT ABOVE DROP CDUNG AND WIRE TO NEW HVAC CONTROLS FOR VAV BOXES. RECEIVED CITY OF TUKWILA NOV 2 9 2015 PERMIT CENTER ISSUED FOR CO 10.02. Q FIRST FLOOR ChD 208Y1120 VOLT POWER PLAN SNE ENGINEERING, INC. TRICAL AND TECHNOLOGY CONSULTANTS LIE 381h PL, SIAM 207 MUM. WA 90033 1000 91112CASAE00M JOB NO. 101-104 W5787963 F SYMBOL a 10.02.18 R. TUCKER 10.09.92 TOLE 11N7 LAB BUILDING 9-98.1 1E62 COUP NO. 1 a 1 i 5 s m DATE SYM 480Y/277 VOLT POWER PLAN SCALE: 1/8'= 1'-0' 11N7 LAB W5787983 CASNE 10.02.18 BOE/NQ' C. UNDER D. TOWNSEND C. UNDER DECKED 09.13.18 09.13.18 09.13.18 ENNEDECT-- TME LEGEND VP FUSED DISCONNECT SYATCH ® EQUIPMENT CONNECTION GENERAL NOTES REFERENCE DRAWINGS CONSTRUCTION NOTES © PROVIDE AND INSTALL 30A FUSED DISCONNECT SWITCH WITH 2OAT CURRENT UMITINC FUSES IN LOCATION AS SHOWN FOR NEW VAV BOX. © PROVIDE AND INSTALL CONDUIT, CONDUCTORS, AND ALL ANCILLARY HARDWARE TO MC -7 IN EAST PENTHOUSE © PROVIDE AND INSTALL FLEX CONDUIT, CONDUCTORS, AND ALL ANCILLARY HARDWARE FROM DISCONNECT SWITCH TO NEW VAV BOX. RECEIVED CITY OF TUKWILA NOV 2 9 2018 PERMIT CENTER ISSUED FOR CON T 10.02. KEY PLAN SCALE: NONE 8' 4' 0 4' 8' SCALE: 1/8-=1'-0' 16' C NE ENGINEERING, INC. CAL AND TECHNOLOGY CONSULTANTS MO H. SUITE 206 MIAMI. MN MOLT 000 NNIRCASEAw .De ND 181-104 FIRST F • - 480Y/277 VOLT POWER 11N7 LAB BUILDING 9-98.1 DATE c 10.02.18 or MPIOXiD SUE FIRST FLOOR FIRE ALARM PLAN SCALE: 1/8'= RECORD DRAWING J/140799-00 DLR GROUP J. BECK 07.23.07 A 11N7 LAB 65787983 CASNE CEC 1002.18 0___IFOE7AVG* MEIN CIA GROUP CRECRED J. BECK X10.06 06.27.06 0 LEGEND B FIRE PANEL m IONIZE SMOKE DETECTOR ® PHOTO ELECTRIC SMOKE DETECTOR t -----DUCT SMOKE DETECTOR ® ANUNNCIATOR IEQ SINGLE STROKE FP • BUZZER D C HORN BELL ® STROBE R:i1 HORN/STROBE MINI HORN/STROBE GENERAL NOTES REFERENCE DRAWINGS CONSTRUCTION NOTES 1. PROVIDE ADDITIONAL STROBES AND/OR HORNS AS REQUIRED FOR NEW WALL LAYOUT. © PROVIDE AND INSTALL 60cd HORN/STROBE IN LOCATION AS SHOWN. CONNECT TO BUILDING FIRE ALARM SYSTEM. ALL CABLING INSIDE SECURE SPACE SHALL BE SHIELDED. ASSURE STROBES ARE SYNCHRONIZED. RECEIVED CITY OF TUKWILA MW 292018 PERMIT CENTER ISSUED FOR CO FIRS1RJ FIRE ALAR TDu 11N7 LAB l BUILDING 9-98.1 L 1E360 1E363 KEY PLAN SCALE NONE 8' 4' 0 4' 8' SCALE: 16' ASNE ENGINEERING, INC. CTRICAL AND TECHNOLOGY CONSULTANTS NE JBN PL. SUIE IIW JO8OAMZ M 00/.33 522-1000 1111WWWIEC0M AB NB 181-101 SNUBS. 787963 1 E262 A DA 10.02.18 JOB NO. .... FIRST FLOOR TELECOMMUNICATIONS PLAN SCALE: 1/8"= 1`-0• ARI@Im RECORD DRAWING J/140799-00 DLR GROUP J. BECK 07.23.07 A 11N7 LAA W5787963 CASNE CEC 10.02.18 31c ACCEPTABILITY SPED ICA tNs D1)ON E9211 6 ANO BY OEPT. OM WINN GRCUP J. BECK TICKER 0510.06 06.27.06 k AAW7e- 4 0 LEGEND 0 SPLIT CHANNEL TELE/POWER POLE. I TELE/DATA OUTLET, RECESS 4• SQ. BOX WITH SINGLE -GANG MUD RING AND BLANK COVERPLATE N TELEPHONE OUTLET, RECESS SINGLE -GANG BOX WITH MUD RING AND BLANK COVERPLATE. ® CEILING MOUNTED DATA OUTLET, RECESS 4• S0. BOX WITH SINGLE -GANG MUD RING AND BLANK COVERPLATE. POWER/DATA FLOOR BOX, TYPE AS NOTED AND SPECIFIED. G CEILING MOUNTED SPEAKER m JUNCTION BOX ® EQUIPMENT CONNECTION, CEIUNG/WALL MOUNT AS REQUIRED, I Ivl GENERAL NOTES 1> CONNECTION FOR BADGE READER. REFERENCE DRAWINGS CONSTRUCTION NOTES PROVIDE AND INSTALL BEN DATA DROP. PROVIDE PULL STRING FOR WIRE PULL BY OTHERS. RECEIVED CITY OF TUKWILA NOV 2 9 2018 PERMIT CENTER SEPA TE ISSUED FOR CONST) +w 10.02.18 • FIRST FLO CQU!R TELECOMMUNICATIONS PLAN TOLE 11N7 LAB R111LDING 9-9A_1.1311 NO AN L D 13 KEY PLAN SGY£: NONE 8' 4' 0 4' 8' 16' SCALE: 1/8•=1'-0• ENGINEERING, INC. TECHNOLOGY CONSULTANTS PL. SU11E 205 N1ML4 MII MIS IIMKCASAECdt MB NO. 181-10 963 1E362 ONE 10.02.18 XS3T7-1/16b XS3T9-1/6,8 LOCATED 9-90 EAST PENTHOUSE PUMP PU—I WATER HEATER WH -1 TEMPERATURE CONTROL PANELS R12/12c 317/3a 3T7/3c R12/12b MC -7 1 1/4"C-314, 16G RED JB NF MC -7 1/2"C-3112, 1120 FAN R-13 AHU-2 LIGHTS AND RECEPTACLE PANEL X3T7 STANDBY XS3T7-1 H' 480-240/120V 7.5 KVA, 1 PH PANEL P8 JB PANEL IU, 3T7 ' 112 1/2KVA PANEL P8-1 R12/12a SUB 27 PMLI 1/2'C-3112, 1120 MC -7 AHU-1 UGHTS AND RECEPTACLE u C-7 2'C-311/0, 160 XS3T7-1/905 4. X EAST PENTHOUSE POWER PLAN SCALE: 1/4' = 1'-0' ■OE A ASI 012 4 140799-00 OUR GROUP — RECORD DRAWING 4140799-00 DR GROUP B 11N7 IAB W5787963 CASNE ACCEPTABIUTY 1X15 csIGV4 AND/0R SPECIREAD R1 5 APPROVED CEC 10.02.18 DEPT. 057E 3/4'R 2112 -OWN MATE MR GROIN 06.27.06 ("imam TJ. ECK 0627.06 MM LEGEND ® 480Y/277V PANEL 208Y/120V PANEL 11111. m TRANSFORMER DI DISCONNECT SWITCH 4 480V 3 PHASE MOTOR. ® EQUIPMENT CONNECTION. GENERAL NOTES 1.) ALL CONDUIT TO 8E 1/2' EMT UNLESS O1HERMSE NOTED. 2.) ALL MARE TO BE 112 THHN/THWN UNLESS OTHERWISE NOTED. 3.) THE FOLLOWING C0L0R CODING OF CONDUCTORS SHALL BE OBSERVED ON ALL CIRCUITS 600 VOLTS OR LESS. 120/208V 277/480V PHASE (LEFT BUS IN PANEL) BLACK BRONX 'B" PHASE (CENTER BUS IN PANEL) RED ORANGE PHASE (RIGHT BUS IN PANEL) BLUE YELLOW NEUTRAL WHITE GRAY EQUIPMENT GROUND GREEN 4.) LARGE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS SHALL BE IDENTIFIED WHEREVER VISIBLE BY APPROPRIATELY COLORED TAPE. 5.) DYMO LABEL ALL RECEPTACLES, JUNCTION BOXES, SWITCHES, ETC., WITH CIRCUIT IDENTIFICATION. 6.) INSTALL REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. 9 RECEIVED CITY OF TUKWILA NOV 2 9 2018 REFERENCE DRAWINGS 09-098—E4 EAST PENTHOUSE ONE—UNE DIAGRAM CONSTRUCTION NOTES © PROVIDE AND INSTALL (2) 20A/3P CIRCUIT BREAKERS IN MC -7 FOR VAV BOXES ON FIRST FLOOR. SEE SHEET 9-98—E4 AND 9-98-1E112. PERMIT CENTER ISSUED FOR CONS 10.02.1a EAST PENTHOUSE 11N7 R1JII TIN(, KEY POE N 4' 2' 0 2' 4' 8' SCALE: 1/4'=1'-0' CE CASNE ENGINEERING, INC. 1..ELECTRICAL50 NTS NE2MIT MOO IEIEI[G4E00Y .[■ Na 18/-105 111 B DAN 10.02.18 COMP NO.