HomeMy WebLinkAboutPermit M18-0162 - GENERAL INSULATION - GAS/ELECTRIC UNITGENERAL INSULATION 410 ANDOVER PARK E M18-0162 Parcel No: Address: City of Tukwila 0 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 0223400071 Permit Number: M18-0162 410 ANDOVER PARK E Project Name: GENERAL INSULATION Issue Date: 12/18/2018 Permit Expires On: 6/16/2019 Owner: Name: Address: Contact Person: Name: R2R INVESTMENTS LLC 7979 S 180TH ST , KENT, WA, 98032 FRED BARBER Address: 6046 LAKE SHORE DR 5 , SEATTLE, WA, 98118 Contractor: Name: CSIHVAC INC Address: 3534 N SHIRLEY, TACOMA, WA, 98407 License No: SCIHVI*880KD Lender: Name: Address: Phone: (206) 310-9007 Phone: (253) 224-8301 Expiration Date: 5/4/2020 DESCRIPTION OF WORK: REMOVE AND REPLACE WITH LIKE KIND GAS/ELECTRIC 5 TON UNIT. Valuation of Work: $13,200.00 Type of Work: REPLACEMENT Fuel type: ELECT Fees Collected: $386.28 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Permit Center Authorized Signature: Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Date: 12 — 15-1? Print Name: fiR-��L_ This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 4: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 8: ***MECHANICAL PERMIT CONDITIONS*** 9: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 10: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** Site Address: 410 Andover Park E Tenant Name: King Co Assessor's Tax No.: Name: R2R Investments, LLC Address: 6046 Lake Shore Dr. S City: Seattle State: Wa Zip: 98118 "'k'a. C • 5 ✓ .b5 - .✓%"&n 4�/pO"idi k ^ f^6 p rl..' Name: Fred Barber Address: 6046 Lake Shore Dr S City: Seattle State: Wa Zip: 98118 Phone: (206) 310-9007 Fax: (206) 722-2826 Email: fredb1226@gmail.com Tukwila Business License No.: Valuation of project (contractor's bid price): $ Describe the scope of work in detail: Remove and replace with like kind gas/electric 5 ton unit Use: Residential: New 0 Commercial: New Fuel Type: Electric IR Gas 13,200 022340-0071-07 Suite Number: Floor: New Tenant: ❑ Yes ❑ ..No 4 y 'a� £3 . $ 1srb� g Company Name: CSI HVAC Address: 3534 N Shirley St City: Tacoma State: Wa Zip: 98407 Phone: (253) 224-8301 Fax: (253) 752-4583 Contr Reg No.: CSIHVI*880KD Exp Date: 05/04/2020 Tukwila Business License No.: Replacement Replacement Other: \ Applieations\Fortns-Applications On Line \2016 Applications\Mechanical Permit Application Revised I-4-16.docx Revised: January 2016 bh Page 1 oft Indicate type of mechanical work being installed and the quantity below: Unit Type t Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent 1 Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm 1 trait Type; . .Qty,. Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system 1 Hood and duct Incinerator — domestic Incinerator — conun/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qtr 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source Residential Residential, Daytime* District of Receiving Property Commercial Industrial 55 dB(A) Residential, Nighttime 45 dB(A) Commercial 57 dB(A) Industrial 60 dB(A) 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-10PM, Monday through Friday and 8AM-10PM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: Warning devices; • Construction and property maintenance during the daytime hours (lam-lOpm); • Testing of backup generators during the day. Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Date: 11/27/2018 Print Name: Fred Barber Day Telephone: (206) 310-9007 Mailing Address: 6046 Lake Shore Dr. S Seattle Wa 98118 City State Zip \Applications\Forms-Applications On Line \2O16 ApplicationsVvlechanical Permit Application Revised 1-4-16.docx Revised: January 2016 bh Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY f PAID $310.20 M18-0162 Address: 410 ANDOVER PARK E Apn: 0223400071 $310.20 MECHANICAL $295.43 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $262.28 TECHNOLOGY FEE $14,77 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R16161 R000.322.900.04.00 0.00 $14.77 $310.20 Date Paid: Tuesday, December 18, 2018 Paid By: R2R INVESTMENTS Pay Method: CHECK 2592 Printed: Tuesday, December 18, 2018 12:15 PM 1 of 1 SYSTEMS Cash Register Receipt City of Tukwila Receipt Number R15958 DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID 76.08 M18-0162 Address: 410 ANDOVER PARK E Apn: 0223400071 $76.08 Credit Card Fee Credit Card Fee R000.369.908.00.00 0.00 $2.22 $2.22 MECHANICAL $73.86 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R15958 8000.322.102.00.00 0.00 $73.86 $76.08 Date Paid: Tuesday, December 04, 2018 Paid By: FRED BARBER Pay Method: CREDIT CARD 04866G Printed: Tuesday, December 04, 2018 11:35 AM 1 of 1 CIVIWYSTEMS et CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA Date: 12/04/2018 11:35:31 AM CREDIT CARD SALE VISA CARD NUMBER: **********7514 K TRAN AMOUNT: $76.08 APPROVAL CD: 04866G RECORD #: 000 CLERK ID: Bill Thank you! Customer Copy Page 2 of 2 httns://classic. convereenay.com/VirtualMerchant/transaction.do?dispatchMethod=printTra... 12/4/2018 INSPECTION RECORD Retain a copy with permit INSP ION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 111-014z, ect; t VT en: i IN& eri igen: Tye of inspection: 1peaumleei. / /AML Address: 44044.0 ?Ark.E • Date Called: Special Instructions: ' Datt Wanted: - 2.6 - O a.m. p.m. e ueste Ri: st Phone No:g wc-s10-9O07 APIAp proved per applicable codes. El Corrections required prior to approval. COMMENTS: e(40,/t cu,�J 7lOCZ Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspEction. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit 1146 x662- ECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: et 4-t In itor Type of I spection: v1 "FA/ -- Address: ^ _ ,_� I1 nr�N t44. (s Date ailed: Special Instructions: Date Wanted: Z- ZS j' G p.m. Requester: Phone No: Approved per applicable codes. 'Corrections required prior to approval. COMMENTS: h1 fns btu -MA? y�rtilt.a 2S` cijJ-r- Inspector: Date: C REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 ject: Pro6/15413444, 048JUIrre/4 Type of Inspection: 1444., Address: Date Called: Special Instructions: Date Wanted: 1,40^ ICt p -m. Requester: jrqua Phone No: W(0-3tO-R 7 Approved per applicable codes. Corrections required prior to approval. COMMENTS: �AideC40444, M 4r I � 4P,P /1/ Inspector: ei7 Date: (fret n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 0 INSPECTION NO. INSPECTION RECORD Retain a copy with permit /0-'30 CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Afik144tjep / `0S of Inspection: rV�, C az Address: 1I1O it4 aleti aut.- E Date Called: Special Instructions: R .f R�L�c.tt RTv l J. 5-IAJ ! Date Wanted: 1-40-i Q 1 C_m. p.m. Requester: Phone No: Zo(o.3to. Roil Approved per applicable codes. orrections required prior to approval. COMMENTS: acitie G ?JM P E - 416 6 '0V tot I,aswA-ria "efirotligt) 4los-1 ThQJIi- Inspector: Date: n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 2 ( ( -3610 $.5 REVISIONS No changes shall be made to the scope of work.without pr!ot approval of the, Tukwila Building Division. NOTE: R'eviSiOns will require a new plan submittal and may Include additional pian review. t 11/30/2018 Google Maps 410 Andover Park E 410 Andover Park E - Google Maps FILE COPY 0 Permit No. Plan review approval is subject to errors and omissions Approval of construction documents Mee not autn ;nze the violation of any adopted code or ordinance Receipt of approved Field Copy and Itlons Is acknowledged: By. _ Date: )2 -las City of Tukwila BUILDING DIVISION mmage,y 048 Google, Map &ta'«,: 013 Gi gie SEPARATE PERMIT REQUIRED FOR: 0 Mechanical a Electrical ®' Plumbing rhr Gas Piping City of Tukwila BUILDING DIVISION 1J1 - 0 I 2_ REVIEVVED FOR CODE COMPLIANCE APPROVED DEC 12 2018 VEL City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA DEC 0 4 2018 PERMIT CENTER https://www.goog!e.com/maps/place/410+Andover+Park+E,+Tukwila,+wA+88188/@47.4525955,-122.2508658,69a,35y,91.43h,45.05t/data=!3m 1 ! 1 e3!... 1/1 'DIVED 'ED FOR COMPLIANCE PROVED 12 2018 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA DEC 0 4 2018 PERMIT CENTER Trane Precedent Gas/Electric Packaged Rooftop IU�e W Application Unit Size Supply Fan External Airflow Static Pressure 2000 cfm 0.500 in H2O DX cooling, gas heat 5 Ton (060) Voltage/phase/hertz 208-230/60/3 MCA 28.30 A MOP 40.00 A External Dimensions (in.) Height Width Length Weight Minimum Maximum 3.41 ft 3.69 ft 5.82 ft 522.0 Ib Entering Dry Bulb 80.00 F Entering Wet Bulb 67.00 F Ambient Temp 95.00 F Leaving Coil Dry Bulb 57.55 F Leaving Coil Wet Bulb 57.55 F Leaving Unit Dry Bulb 59.34 F Leaving Unit Wet Bulb 58.24 F Refrigeration System Options Leaving Dew Point 57.56 F 797.0 Ib EER 12.0 EER Unit Controls Electro mechanical controls 3ph Heating Stages 2 Output Heating Capacity 81.00 MBh Output Heating Capacity with Fan 83.22 MBh Heating EAT 70.00 F Heating LAT 107.80 F Heating Temp Rise 37.80 F Indoor Fan Type FC Centrifugal Drive Type Direct Indoor Fan Performance Airflow 2000 cfm Design ESP 0.500 in H2O Indoor Motor Operating Power 0.72 bhp Indoor Motor Power 0.54 kW Indoor RPM 1027 rpm Indoor Fan FLA 0.00 A Capacity Gross Total 59.98 MBh Gross Sensible 49.31 MBh Net Total 57.75 MBh Net Sensible 47.08 MBh Fan Motor Refrig Charge-cir 2018-04-26 16:58:06Z Power 0.00 kW Circuit 1 RLA 0.00 A Circuit 2 RLA 1.40 A M18- 0162 -71 IEER/SEER CODE�. IEINED FOR CODpE COMPLIANCEp APPROVED C 12 2018 Outdoor Fan b Type Propeller Fan Quantity 1 Drive Type Direct Outdoor Fan Performance Condenser Fan FLA 0.00 A Exhaust Fan Data Type FC Centrifugal Drive Type Direct Exhaust Fan Performance Exhaust Fan FLA 0.00 A RECEIVED CITY OF TUKWILA DEC 0 4 2018 Page 1 of 9 PERMIT CENTER MANE ,lot? Name. Preva ed By:. Unit Tag YSC,060G iE.MB' O Quantity 1 EVAPORATOR SECTION ACCE SS PANEL TOP PANEL CONDENSER FAN CONDENSATE DRAIN (ALT) 3f4"-14 NPT DIA.. HOLE 4 114 - THROUGH THE BASE CONDENSATE 42 114` PLAN VIEW UNIT DIMENSION DRAWING 2018-04-26 16:58:06Z CONDENSER COIL UNIT CONTROL WIRE 778' DIA. HOLE SERVICE GAUGE PORT ACCESS 1 3/6" DIA. HOLE UNIT POWER WIRE CONTROLAND COMPRESSOR ACCESS PANEL 1/7 NPT GAS CONNECTION NOTES: 1.THRU -THE -BASE GAS AND ELECTRICAL IS NOT STANDARD ON ALL UNITS. 2 VERIFY WEIGHT. CONNECTION, AND ALL DIME NSION WITH INSTALLER DOCUMENTS BEFORE INSTALLATION 40 1.11111 20 114- 4518" 55/8" SUPPLY IRETURN 143/4" 4 114' 59/15 II .11 71 44114 - 2018-04-26 16:58:06Z CONDENSER COIL UNIT CONTROL WIRE 778' DIA. HOLE SERVICE GAUGE PORT ACCESS 1 3/6" DIA. HOLE UNIT POWER WIRE CONTROLAND COMPRESSOR ACCESS PANEL 1/7 NPT GAS CONNECTION NOTES: 1.THRU -THE -BASE GAS AND ELECTRICAL IS NOT STANDARD ON ALL UNITS. 2 VERIFY WEIGHT. CONNECTION, AND ALL DIME NSION WITH INSTALLER DOCUMENTS BEFORE INSTALLATION 40 PACKAGED GAS / ELECTRICAL DIMENSION DRAWING HORIZONTAL AIR FLOW Page 2 of9 1.11111 20 114- 4518" 55/8" ' 4 114' 59/15 II .11 7 5/8" 44114 - PACKAGED GAS / ELECTRICAL DIMENSION DRAWING HORIZONTAL AIR FLOW Page 2 of9 2018-04-28 113:58:082 Prepa,e(1 •n,t 3/4%14 NPT DRAIN CONNECTION 23 9/16' ISOMETRIC -PACKAGED COOLING Page 3 of 1:):,>v:.,� ELECTRICAL / GENERAL DATA GENERAL ,«4r; HEATING PERFORMANCE Model YSCO60G Oversized M oto r HEATING -GENERAL DATA Unit Operating Voltage: 187-253 MCA N/A Unit Primary Voltage: Unit Secondary Voltage 208 230 MFS: N/A MCB'. NIA Heatn 11 eating Model' Input odeP 9 P (BTU). Medium 100800/70600 Unit Hertz: 60 4eating Output (BTU(' 81.040/56,700 Unit Phase: N o. Burners: 3 No. Stages 2 EE RISE ER 12.0/14.0 Standard Motor Field Installed Oversized M otor Gas Inlet Pressure MCA 282 MCA N/A Natural Gas (MINN aj: 4.5/14.0 MFS: 40.0 MFS. N/A LP (M in/Max) 11.0/14.0 MC B: 40.0 MC B. N/A Gas Pipe Connection Size. 1/2 - INDOOR MOTOR Standard M otor Oversized Motor Field Instaled 0verszed M otor Number 1 Number: N/A Number. N/A Horsepower 1.0 Horsepower N/A Horsepower: NIA Motor Speed (RPM): — Motor Speed (RPM 1 1A Motor Speed (RPM ): NIA Phase 1 Phase N/A Phase 1/A Full Load Amps: 6.9 Full Load Amps N A Full Load Amps N/A Lolled RotorAmps _ Locked Rotor Amps: NIA Locked RotorAmps N/A COMPRESSOR Circud 112 OUTDOOR MOTOR Number: 1 Number: 1 Horsepower 4.3 Horsepower 0.40 Phase' 3 Motor Speed (RPM p 1100 Rated Load Amps. 15.9 Phase' 1 Locked Rotor Amps: 110.0 Fu N Load Amps: 1.4 Locked Rotor Amps 0.2 POWER EXHAUST ACCESSORY `3' FILTERS REFRIGERANT (2) (Field Installed Power Exhaust) Type Phase: N/A Tye, Throwaway Horsepower: 14/4 Furnished: Yes Factory Charge Motor Speed (RPM j: 1/A Number 2 Circuit el 4.8 is Full Load Amps: N/A Recommended 20`k35`x2" Circuit42 NtA Locked Rotor Wraps: N/A NOTES. 1. M aximu m (HACR) Circuit Breaker sizing is for installations m the U n ted States only. 2. Refrigerant charge is an approximate value. For a more precise value. see unit nameplate and service instructions 3. Value does not include P ower E Mi gust Accessory 4. Value incudes oversized motor 5. Value does not include Power Exhaust Accessory. 6. EER is rated at AH RI conditions and in accordance with DOE test procedures. 2018-04-28 16:58:062 Page 4 of 9 N3Me. t Mft PACKAGED GAS / ELECTRICAL CORNER WEIGHT D 0 INSTALLED ACCESSORIES NET WEIGHT DATA ACCESSORY WEIGHTS ECONOMIZER MOTORIZED OUTSIDE AIR DAMPER MANUAL OUTSIDE WR DAMPER BAROMETRIC RELIEF OVERSIZED MOTOR BELT DRIVE MOTOR POWER EXHAUST THROUGH THE BASE E LECTRICAUGAS(FIOPS) UNIT MOUNTED CIRCUIT BREAKER (HOPS) UNIT MOUNTED DISCONNECT (HOPS) POWERED CONVENIENCE OUTLET (FIOPS) HINGED DOORS tf IOPS) HAIL GUARD SMOKE DETECTOR. SUPPLY/ RETURN NOVAR CONTROL STAINLESS STEEL H EAT EXC HANGER REHEAT ROOF CURB BASIC UNIT WEIGHTS CORNER WEIGHTS CENTER OF GRAVITIY SHIPPING NET 0 214.O lb 0 52.0 b SE) LEN GMT (F) WIDTH 627.0 Ib 522.0 lb O 193.0 Ib 0 63.0 b 33" 10" 1 All weights areapproroma e. 2. Weights for options that are not list refer to Installation guide. 3. The actual %,eight are listed en the unit nameplate. 4. Refer to unit nemepiate and installation guide for weights b etre scheduling transportation and installation of unit. 5. The weight shown represents the typical unit operating weight for the configuration selected Estimated at .1- 10 % of the nameplate weight. 6. Vent' weight, connection. and al dimension vath installer documents before installation. 7. Corner weights are given for information only. 8. Net/Shipping weight of optional accessories should be added to unt weight when ordering factory or fold installed accessories. PACKAGED GAS 1 ELECTRICAL RIGGING AND CENTER OF GRAVITY 2018-04-26 16:56062 Page 5 of 9 CLEARANCE 36" CLEARANCE 48" DOWNFLOW CLEARANCE 36" HORIZONTAL CLEARANCE 18" ROOF OPENING UNIT OUTLINE CLEARANCE 36" PACKAGED GAS / ELECTRIC CLEARANCE 37" CLEARANCE FROM TOP OF UNIT 72" 44 1/2- 40 58 3116' PACKAGED GAS / ELECTRIC DOWNFLOW TYPICAL ROOF OPENING 2018-04-26 16.58:06Z Page 6 of 9 epal ed General The units shall be convertible airflow. The operating range shall be between 115°F and 0°F in cooling as standard from the factory for units with microprocessor controls. Operating range for units with electromechanical controls shall be between 115°F and 40°F. Cooling performance shall be rated in accordance with ARI testing procedures. All units shall be factory assembled, internally wired, fully charged with R -410A, and 100 percent run tested to check cooling operation, fan and blower rotation, and control sequence before leaving the factory. Wiring internal to the unit shall be colored and numbered for simplified identification. Units shall be cULus listed and labeled, classified in accordance for Central Cooling Air Conditioners. Casing Unit casing shall be constructed of zinc coated, heavy gauge, galvanized steel. Exterior surfaces shall be cleaned, phosphatized, and finished with a weather -resistant baked enamel finish. Unit's surface shall be tested 672 hours in a salt spray test in compliance with ASTM B117. Cabinet construction shall allow for all maintenance on one side of the unit. Service panels shall have lifting handles and be removed and reinstalled by removing two fasteners while providing a water and air tight seal. All exposed vertical panels and top covers in the indoor air section shall be insulated with a cleanable foil - faced, fire -retardant permanent, odorless glass fiber material. The base of the unit shall be insulated with 1/8 inch, foil -faced, closed -cell insulation. All insulation edges shall be either captured or sealed. The unit's base pan shall have no penetrations within the perimeter of the curb other than the raised 1 1/8 inch high downflow supply/return openings to provide an added water integrity precaution, if the condensate drain backs up. The base of the unit shall have provisions for forklift and crane lifting, with forklift capabilities on three sides of the unit. Unit Top The top cover shall be one piece construction or, where seams exist, it shall be double -hemmed and gasket -sealed. The ribbed top adds extra strength and enhances water removal from unit top. Filters Throwaway filters shall be standard on all units. Optional 2 -inch MERV 8 and MERV 13 filters shall also be available. Compressors All units shall have direct -drive, hermetic, scroll type compressors with centrifugal type oil pumps. Motor shall be suction gas-cooled and shall have a voltage utilization range of plus or minus 10 percent of unit nameplate voltage. Internal overloads shall be provided with the scroll compressors. Dual compressors are outstanding for humidity control, light load cooling conditions and system back- up applications. Dual compressors are available on 71/2-10 ton models and allow for efficient cooling utilizing 3 -stages of compressor operation for all high efficiency models. Indoor Fan The following units shall be equipped with a direct drive plenum fan design (T/YSC120F,T/YHC074F, T/YHC092F,T/YHC102F, 120F). Plenum fan design shall include a backward -curved fan wheel along with an external rotor direct drive variable speed indoor motor. All plenum fan designs will have a variable speed adjustment potentiometer located in the control box. 3 to 5 ton units (high efficiency 3-phase with optional motor) are belt driven, FC centrifugal fans with adjustable motor sheaves. 3 to 5 ton units (standard and high efficiency 3-phase) have multispeed, direct drive motors. All 6 to 8'h ton units (standard efficiency) shall have belt drive motors with an adjustable idler -arm assembly for quick -adjustment to fan belts and motor sheaves. All motors shall be thermally protected. All 10 tons, 6 ton (074), 71/2 to 81 (high efficiency) units have variable speed direct drive motors. All indoor fan motors meet the U.S. Energy Policy Act of 1992 (EPACT). 2018-04-26 16:58:06Z Page 7 of 9 :are1 Ey Outdoor Fans The outdoor fan shall be direct -drive, statically and dynamically balanced, draw -through in the vertical discharge position. The fan motor shall be permanently lubricated and shall have built-in thermal overload protection. Evaporator and Condenser Coils Internally finned, 5/16" copper tubes mechanically bonded to a configured aluminum plate fin shall be standard. Evaporator coils are standard for all 3 to 10 ton standard efficiency models. Microchannel condenser coils are standard for all 3 to 10 ton standard efficiency models and 4, 5, 6, 7.5, 8.5 ton high efficiency models. The microchannel type condenser coil is not offered on the 4 and 5 ton dehumidification model. Due to flat streamlined tubes with small ports, and metallurgical tube -to -fin bond, microchannel coil has better heat transfer performance. Microchannel condenser coil can reduce system refrigerant charge by up to 50% because of smaller internal volume, which leads to better compressor reliability. Compact all -aluminum microchannel coils also help to reduce the unit weight. These all aluminum coils are recyclable. Galvanic corrosion is also minimized due to all aluminum construction. Strong aluminum brazed structure provides better fin protection. In addition, flat streamlined tubes also make microchannel coils more dust resistant and easier to clean. Coils shall be leak tested at the factory to ensure the pressure integrity. The evaporator coil and condenser coil shall be leak tested to 600 psig. The assembled unit shall be leak tested to 465 psig. The condenser coil shall have a patent pending 1+1+1 hybrid coil designed with slight gaps for ease of cleaning. A plastic, dual -sloped, removable and reversible condensate drain pan with through -the -base condensate drain is standard. Controls Unit shall be completely factory -wired with necessary controls and contactor pressure lugs or terminal block for power wiring. Unit shall provide an external location for mounting a fused disconnect device. A choice of microprocessor or electromechanical controls shall be available. Microprocessor controls provide for all 24V control functions. The resident control algorithms shall make all heating, cooling, and/or ventilating decisions in response to electronic signals from sensors measuring indoor and outdoor temperatures. The control algorithm maintains accurate temperature control, minimizes drift from set point, and provides better building comfort. A centralized microprocessor shall provide anti - short cycle timing and time delay between compressors to provide a higher level of machine protection. 24 -volt electromechanical control circuit shall include control transformer and contactor High Pressure Control All units include High Pressure Cutout as standard. Phase monitor Phase monitor shall provide 100% protection for motors and compressors against problems caused by phase loss, phase imbalance, and phase reversal. Phase monitor is equipped with an LED that provides an ON or FAULT indicator. There are no field adjustments. The module will automatically reset from a fault condition. Refrigerant Circuits Each refrigerant circuit offer thermal expansion valve as standard. Service pressure ports, and refrigerant line filter driers are factory -installed as standard. An area shall be provided for replacement suction line driers. 2018-04-26 16:58:06Z Page 8 of 9 r Nime P,e; r 'e(7 Ey Ta. vs::060,7:1FErni Gas Heating Section The heating section shall have a progressive tubular heat exchanger design using stainless steel burners and corrosion resistant steel throughout. An induced draft combustion blower shall be used to pull the combustion products through the firing tubes. The heater shall use a direct spark ignition (DSI) system. On initial call for heat, the combustion blower shall purge the heat exchanger for 20 seconds before ignition After three unsuccessful ignition attempts, the entire heating system shall be locked out until manually reset at the thermostat/zone sensor. Units shall be suitable for use with natural gas or propane (field -installed kit) and also comply with the California requirement for low NOx emissions (Gas/Electric Only). 2018-04-26 16:58:06Z Page 9 of 9 SINGLE PACKAGE AIR-COOLED CONVERTIBLE SERIES AIR CONDITIONERS DCHB / DDUC 036, 048, 060 & 076 DEUC 060 3, 4 AND 5 NOMINAL TONS (10 SEER) 6 NOMINAL TONS (9 EER) RE CODE C APPRO DEC 12 2018 City of Tukwila BUILDING DIVISION MODEL DUC RECEIVED CITY OF TUKWILA DEC 0 4 2018 PERMIT CENTER MIR- OIL DESCRIPTION 530.18 -TG 1 L (993) t. The DHB and DUC units are convertible single package air conditioners with a common cabinet and a common roof curb for the 3, 4, 5 and 6 ton sizes. The units were designed for residential and light commercial applications. They can easily be installed on a roof curb, slab, roof jack or frame. All units are self-contained and assembled on rigid full perimeter base rails with fork lift slots on three sides and holes for overhead rigging. Every unit is completely piped, wired, charged and tested at the factory to provide for a quick and easy field installation. The units are available in cooling only, and cooling with gas heat. Electric heaters are available as field -installed accessories. Both bottom and side duct connections are available without having to swap panels. The installer simply removes the duct covers for the desired configuration. Economizers may be used on either bottom and side duct applications with no modifications required. All models include a 5 -year limited warranty on compressors and electric heating elements, a 10 -year limited warranty on gas-fired heat exchangers and a 1 -year limited warranty on all replacement parts. FEATURES COMMON FOOTPRINT/COMMON CABINET -AH model sizes and configurations share a common cabinet and a common roof curb. The installer has the flexibility of setting one curb and placing the lroper tonnage unit on that curb after the intemal oad has been determined. He can even decide between gas or electric heat afterthecurb has been set. HIGH EFFICIENCY - All units have a high cooling efficiency; and gas / electric models have a minimum AFUE of 79%. All efficiencies exceed legislated minimum levels and provide low operating costs. CONVERTIBLE AIRFLOW DESIGN - Both the side and bottom duct openings are covered when they leave the factory. If a side supply / side return is desired, you simply remove the two side duct covers from the outside of the unit and discard them. If a bottom supply / bottom return is desired, you simply remove the two knockout panels from the base of the unit and discard them. No panel cutting or swapping is required! Convertible airflow design allows maximum field flexibility and minimum inventory. FACTORY -INSTALLED OPTION - Adjustable belt -drive blower is available on 5 and 6 ton, 3-phase units from the factory to provide maximum air flow flexibility. FIELD -INSTALLED ACCESSORIES - Accessories were designed for quick and easy installation. The motorized damper and economizers simply slide in, and electrical connections are made by modular plugs. Electric heaters mount easily, and knockouts are provided in the intemal partitions to connect the elements to the control box single point kit. Cont'd. 530.18 -TG 1 FEATURES - CONT'D. The 14" high roof curb is shipped knocked down. An insulated deck is not required because the bottom of the unit is insulated. Low ambient controls are available to provide stable unit operation at outdoor temperatures down to 0°F. Propane, high altitude and low NOx kits are also available to cover all gas heating applications. WIDE RANGE OF INDOOR AIRFLOWS - All 3, 4 and 5 -ton models operate over a wide range of design conditions with a 3 -speed direct -drive fan motor. The 6 -ton unit has a single speed direct -drive fan motor. Belt -drive blowers are also available on 5 and 6 ton, 3-phase models. FULL PERIMETER BASE RAILS - The permanently attached base rails provide a solid foundation for the entire unit and protect the unit during shipment. The rails provide fork lift access from 3 sides, and rigging holes are also provided so that an overhead crane can be used to place the units on a roof. SYSTEM PROTECTION - Crankcase heat and internal overload protection are standard on all compressors. Every unit has a liquid line filter -drier, high and low pressure switches and a suction line freezestat to protect all system components. Ail units will provide cooling at ambient temperatures down to 45°F. UTILITY CONNECTIONS MADE EASY - Gas and electric utility knockouts are provided in the unit base as well as the side of the unit. Aclearly identified location is provided to mount a field supplied electrical disconnect switch. Utility connections can be made quickly and with a minimum amount of field labor. SIMPLE CONTROL CIRCUIT - A low voltage printed circuit board contains a compressor lockout indicator fight and a low voltage terminal strip. An additional set of pin connectors is also provided to simplify the field interface of external controls. Mate -n -lock plug connectors are used where line and low voltage wires pass thru intemal bulkheads. This allows for easier troubleshooting and component replacement. The electrical control box is not located in the compressor compartment so the access cover can be removed for troubleshooting without affecting the normal system operating pressures, AIR FILTERS - Units are shipped with 1* throwaway filters. The unit filter racks can accommodate 1" or 2" filters without any modifications. HIGH -EFFICIENCY CONVERTIBLE ROOFTOP LOW VOLTAGE RELAY BOARD 20 GAUGE ALUMINIZED STEEL AND TERMINAL STRIP TUBULAR HEAT EXCHANGER ELECTRICAL DISCONNECT MOUNTING LOCATION (Field Installed) ECONOMIZER H000 DIRECT -DRIVE BLOWER MOTOR (Bet -Drive Option also avaiable on some models) ELECTRIC HEAT ACCESSORY LOCATION (EledElec Units) POWER VENTER MOTOR COPPER TUBE/ ALUMINUM RN CONDENSER COIL OUTDOOR AIR OPENING FOR SLIDE-IN/PLUG IN INTERNAL ECONOMIZER (ACCESSORY) SIDE RETURN AIR DUCT OPENING (Retum Air & Supply Ai Side by Side) BOTTOM RETURN AIR DUCT OPENING (Retum Air & Supply Ai S ide by Side) 3'4' PVC FEMALE CONDENSATE DRAIN KNOCKOUTS FOR SIDE POWER AND CONTROL ENTRY TERMINAL BLOCK (For Single Point Power Supp' on Elec/Elec Units) KNOCKOUT FOR BOTTOM GAS SUPPLY ENTRY KNOCKOUT FOR BOTTOM POWER ENTRY HIGH EFFICIENCY COMPRESSORS WITH CRANKCASE HEAT BASE RAILS WITH FORKLIFT SLOTS AND LIFTING HOLES KNOCKOUT FOR SIDE GAS SUPPLY ENTRY Description ................ Features ..................... Ratings ...................... Physical Data ............. Component Weights.., Cooling Capacities - 3 'ooling Capacities - 4 ooling Capacities - 5 Cooling Capacities - 6 Blower Performance - Biower Performance - 2 TABLE OF CONTENTS •1 1 3 3 Ton.4 Ton................................................... 5 Ton.6 Ton...................................................7 5 & 6 Ton wBelt-Drive...................... 8 3 - 6 Ton w/Direct-Drive.................... 9 MODEL DUC (Gas Heating) Option and Accessories... ......... ....................... ..............9 Static Resistances..............................................................10 Motor and Drive Data ............................... ..........................10 Electrical Data - Basic Units w/Direct-Drive .......................10 Electrical Data - Basic Units w/Belt-Drive ..........................10 Elec. Data-CIgiEIec. Htg. w/Direct-Drive........................... 11 Elec. Data-ClgiElec. Htg. w/Belt-Drive..............................13 Field Wiring. .14 UnitDimensions.................................................................15 Roof Curb Dimensions.......................................................17 Typical Applications............................................................18 Central Environmental Systems RATINGS • L.MrAL.i i T HAI irliaa - LOonng / tiectric Healing Vv�V v II.ARI GAS HEAT CAPACITY ARI RATINGS1 NOMINAL COOLING CAPACITY 80 / 67-95°F SOUND RATING2 MODEL ELECTRIC HEAT CAPACITY3 (KW) 12 x 10 3/4 - MBH SEER EER - (bels) 240V 480V 600V DH8036 40 10.10 ................ Q#>>; 8.6 , 5 7, 10, 7, 10, 10, EER 1 16 17 1 (belsj 1 22 17 1 (MBH) 15&20 15&20 15&20 DHB048 48 10.35 "'s#) 8.6 5 7, 10, 7, 10, 10, 41 81.0 81.0 ;•::,:;;.>_ , 15-45 15&20 15&20 15&20 DHB060 >:#>>.':; 8.6 100 82 5, 7, 10, 7, 10, 15 10, 15, 40-70 59 10.15' 48 8.6 15,20 &30 20 & 30 20 &30 DHB076 75 - 9.00 8.4 5 7, 10, 7, 10, 15, 10, 15, 10.35 :>:>9:4rs:<:: 8.6 125 101 15,20&30_ 20&30 20 & 30 CAPACITY RATINGS - Cooling / Gas Heating 530.18-TG1 208f230, 460 VOLT 208/230, 575 VOLT Ratings are it acoordanoe wfth ARI Standard 210. Sound ratings are in accordance will ARI Standard 270. 3i -teeters are available as accessories - all wth single point power supply. SEER =Seasonal Energy Efficiency Ratio - the total Goofing output to BTU'a during a normal annual usage period for 000lin divided the total electric 9 by cower input In w s during a same period. EER = Energy Efficiency Ratio - the ooc4ng capacity in Btu'vidati per hour (Blah) ded by.the power input in wattsany given setof rating conditions, expressed ed h n BTUH per watt (STUN/watt). AFUE=Annual Fuel Utilization Elflaency- determined in accordance wth DOE test procedure. S.S.E. = Steady State Efficiency. (Percent Output). S.E. =California Seasonal Efbienoy - determined in accordance wih test procedurea as specified by the State of California Energy Commission. Furnaces ere available with a low NOx accessory. 1...1.,.11 Not ARI Listed. PHYSICAL DATA - BASIC UNIT MODELS RATINGS 1 Vv�V v II.ARI GAS HEAT CAPACITY MODEL COOLING CAPACITY SOUND INPUT OUTPUT AFUE 12 x 10 3/4 - 12 x 10 1 1 5 TEMP. GAS ,�N ROWS DEEP FINS PER INCH FA.CEAREA (Sa. FL) 80 / 67-95°F RATING2(MBH) 3 5 1 3 5.1 SER CONDENSER S.S.E. S.E. RISE LINE SIZE MBH SEER EER 1 16 17 1 (belsj 1 22 17 1 (MBH) (%j (%) (%) (°F) (in. OD) DUC036N050 40 10.10 >39> s 8.6 50 41 81.0 81.0 71.0 15-45 1/2 DUC036N100 40 10.10 >:#>>.':; 8.6 100 82 80.0 81.0 71.0 40-70 1/2 DUC048N075 48 10.35 8.6 75 62 80,5 80.0 71.5 25-55 1/2 DUC048N125 48 10.35 :>:>9:4rs:<:: 8.6 125 101 79.0 80.0 73.0 45-75 1/2 DUCO6ON100 59 10.15 ?>: 8.6 100 79 79.0 80.0 72.0 25-55 1/2 DUC060N125 59 10.15 <zz9s<N•s 8.6 125 101 80.0 80.0 73.5 35-65 1/2 DUC076N100 75 - 9.00 8.4 100 82 80.5 80.0 71.0 25-55 1/2 DUC076N125 75 - 9.00 84 125 101 80.0 80.0 71,5 35-65 1/2 Ratings are it acoordanoe wfth ARI Standard 210. Sound ratings are in accordance will ARI Standard 270. 3i -teeters are available as accessories - all wth single point power supply. SEER =Seasonal Energy Efficiency Ratio - the total Goofing output to BTU'a during a normal annual usage period for 000lin divided the total electric 9 by cower input In w s during a same period. EER = Energy Efficiency Ratio - the ooc4ng capacity in Btu'vidati per hour (Blah) ded by.the power input in wattsany given setof rating conditions, expressed ed h n BTUH per watt (STUN/watt). AFUE=Annual Fuel Utilization Elflaency- determined in accordance wth DOE test procedure. S.S.E. = Steady State Efficiency. (Percent Output). S.E. =California Seasonal Efbienoy - determined in accordance wih test procedurea as specified by the State of California Energy Commission. Furnaces ere available with a low NOx accessory. 1...1.,.11 Not ARI Listed. PHYSICAL DATA - BASIC UNIT MODELS DHB/D_ JC 036 048 060 078 EVAPORATOR BLOWER CENTRIFUGAL BLOWER (Dia. x Wd. in.) FAN MOTOR HP (DIRECT DRIVE) M•TOR HP (BELT -DRIVEL 12 x 10 1/2 12 x 10 3/4 - 12 x 10 1 1 5 12 x 11 1 1.5 EVAPORATOR COIL ,�N ROWS DEEP FINS PER INCH FA.CEAREA (Sa. FL) 3 13 6 3 3 13 3 5 1 3 5.1 SER CONDENSER PROPELLER DIA. (in.) FAN MOTOR HP NOM CFM TOTAL 22 - 1/2 4 500 22 1/2 4 200 22 1/2 4 500 24 1/2 4.500 CONDENSER COIL ROWS DEEP FINS PER INCH EACEAREA�Sq,..Ft.1 1 16 17 1 1 19 17 1 1 22 17 1 2 16 16.7 AIR FILTERS (SEE NOTE) QUANTITY PER UNIT14" X 20" X 1" QUANTITY PER UNIT (14" X 25' X 1") TOTAL FACE AREA(sq. ft.) 2 1 6.3 2 1 6.3 2 1 6.3 2 1 6.3 CHARGE REFRIGERANT 22 (Ihs /071 6(0 F/6 7/4 11/8 NOTE: Filter racks are adapted for 1' or 2' thick titers. COMPONENT WEIGHTS Basic Unit COMPONENT DHB (Cooling only), MODELS DHB & DUC 3TON 4 TC)N 5 TC)N DUC (Gas / Electric) 50 Mbh 75 Mbh 100 Mbh 125Mbh 545 585 610 605 6 TON 670 645 615 655 670 680 Options and Accessories Belt -Drive Blower 5 Economizer Motorized Outdoor Air Damper Electric Heat (Nominal KW) (DHB only) 5 - 7 KW 50 48 18 725 735 5 10 - 15 KW 20-3QKW Roof Mounting Curb Relief / Fixed Air Damper NOTE: Weights are given in pounds. Central Environmental Systems 23 28 92 10 3 530.18-TG1 COOLING CAPACITIES - 3 TON (DHB / DUC036 Air On • , Temperature of Air on Condenser Coil Evaporator Coil 85°F AnnfrlearWAWEINEMOS:11g1 Power Input' Total Power input' KW Sensible Capacityl, MBHTotal Cap.1 MBH Power Input' KW Sensible Capacity, MBH CFM WB °F Cap) MBH Enterin 0 Bulb °F Enterirtd Dry Bulb. °F 86 83 80 77 74 71 68 86 83 NNOli 77 74 71 68 1750 72 67 62 57 49 47 44 43 3.4 3.3 32 3.2 36 43 ....„......... 44 :::. $i 31 40 43 gi'00:50S 27 35 42 22 31 38 38 - 27 34 34 - 22 30 30 - - 25 25 48 45 41 40 3.7 3,6 3.6 3.4 35 39 41"41.' !W 31 38 ....„ 27 34 39 liN&::i 22 30 36 36 - 25 32 32 - 21 27 27 - - 23 23 1500 72 67 62 57 48 45 41 41 3.3 3.3 32 3.1 33 41 41 41 29 37 4. 4 25 33 40 441e 21 29 36 37 - 25 32 33 ,- 21 28 29 - - , 24 26 46 43 39 39 3.6 3.5 35 34 32 pp 89 '::39 29 p§ 9 i.: 25 31 38 21 27 34 35 - 23 30 31 - 20 26 27 - - 22 23 I 400 72 67 62 57 47 44 41 41 3.3 3.2 3.1 3.1 32 39 -::m:: :. 28 36 '"" ""'" i:M:ii: 24 32 .. i:: 21 28 35 37 - 25 31 33 - 21 28 30 - - 24 26 46 43 39 383.4 3.6 3.5 3A 31 :::: 3.7 :-::':4 •• . , 4 27 ,:ii:ii .: 24 30 37 ::::-::::.., ' / 20 27 33 34 - 23 30 31 - 19 26 27 - - 22 23 gres.. 72 62 57 45 42 39 39 32 32 3.1 3.1 29 36 ,!:39 9 25 32 89 39 22 29 35 37 ' 19 26 32 34 - 23 29 31 - 20- 26 27 - 22 24 ,.., 43 ....... ,....mfate 36 36 36 34 3.4 28 34 '''i,...*"' 25 31:,......:l2 'Ogig 6N: 23 29 35i:ii ::: .....22,.... 34 35 20 26 32 32 19 24 31 32 17 23 29 29 - 21 27 28 - 20 26 27 - 18 24 25 - 17 23 24 - 21 22 - - 20 21 1050 72 67 62 57 43 40 37 37 3.2 3.1 3.1 3,0,C4ei 26 33 .....'''87'''..:' 23 30 36 20 , 27 33 34 18 24 30 32 - 21 27 29 - 19 24 26 - - 21 23 41 38 35 34 3.5 3.4 3.3 3.3 26 31 8S ,... c ii 4'4 900 72 67 62 57 41 39 36 36 3.1 3.1 3.0 3.0 24 30 35 gn 21 27 33 34 19 25 30 32 16 23 28 29 r - 20 25 27 - 18 23 24 - - 20 _ 22 39 36 33 32 3.4 34 3.3 3.2 24 29 . A 21 26 :...32... AgS 19 24 29 30 16 21 27 27 - 19 24 25 17 22 23 - - 19 20 Air On Evaporator Coil Temperature of Air on Condenser Coil 105°F 115°F Total Power Input' Sensible Capacityl, MBHTotal , Cap.1 Rowel Input' • Sensible Capaetyl, MBH • CFM wg Cap.1 Enterin q Dry Bulb. °F Enterin z Dry Bulb, °F °F MBH KW 86 83 80 77 74 71 68 MBH KW 86 83 80 77 74 71 68 72 45 4.0 34 30 26 21 - - - 43 4.2 33 29 25 20 - - - 1750 67 62 41 38 3.9 3.9 37 39 p7 3 33 37 29 33 24 29 20 24 - 20 37 34 4.1 4.1 35 ,,,,:,::;:::::.:.:. 34 p4 • 32 .x...:, 28 30 23 26 19 21 - 17 57 38 3.8 :iiligi::::A 37 33 29 24 20 34 4.0 4 ' ''' . " 30 26 21 17 72 44 3.9 31 27 23 20 - - - 41 4.1 ..:.10... 26 22 18 - - - 1500 67 62 39 36 3.8 3.8 35 •• •..... 34 iiii::•:::i:::::: 30 35 26 32 22 28 18 24 - 20 35 33 4.0 4.0 ,35'. 33 *,•:•:•:•,•:.::•,;,,,:i., , 29 38 25 29 21 25 17 21 - 18 57 36 3.7 35 32 28 24 20 33 3.9 1 :::;:3 29 25 21 19 72 43 3.9 30 26 23 19 - - - 41 4.1 29 25 22 18 - - - 1400 67 39 3.8 36 '''-36i: 33 29 25 22 18 - 35 4.0 32 32 28 24 21 17 - 62 36 3.7 318.,:- 35 31 27 24 20 33 4.0 38 83-,::,:, :::33 29 25 22 18 57 36 3.7 3836 35 32 28 24 20 33 39 33 'W:ii::::**i ,..: 29 25 22 18 72 41 3.9 27 24 21 17 - - - 39 4.1 26 23 19 16 - • - 1200 67 37 3.8 32 30 27 23 20 17 - 33 4.0 pp 29 25 22 19 16 - 62 34 3.784 ,: i....: 32 29 25 22 19 31 4.0 • 30 26 23 20 17 57 33 3.7 ' 32 29 26 22 19 31 3.9 41 4; 30 26 23 20 17 72 39 3.8 25 22 19 16 - - - 37 4.0 24 21 18 15 - - - 1050 67 35 3.7 pp g 25 22 19 16 - 32 3.9 p gs 23 20 18 15 - 62 32 3.6 ' 22 32 29 27 24 21 18 30 3.9 • 20i 27 24 22 19 16 57 32 3.8 4 30 27 24 21 18 30 3.8 ::, :' 27 24 23 19 16 72 37 3.7 22 20 18 15 - - - 36 4.0 21 19 16 14 - - 900 67 34 3.7 g7 •:•:•:x.m:i: .3.1iii 25 23 20 18 15 - 31 3.9 a:.,,, 24 21 19 16 14 - 62 31 3.6 29 27 25 22 20 17 29 3.8 9 27 25 22 20 17 15 r_. 57 • 31 3.5 - 30 27 25 22 20 17 29 3.8 27 25 22 20 17 15 re gross ratrige. For net eapacrty,detenrine the KW of the supply air blower motor from the Blower Performance Table, multiply this value by 3.415 MBH/ KW to detemine the motor heat, and deduct this heat from the gross capacity of the unit. 2 These ratings include the compressor and the condenser fan motors but not the supply air blower rrotor. The total condenser fan motor power input is 0.36 KW. Refer to the Blower Performance Table for the KW of the supply air blower motor. Ktmimi, NOMINAL RATING 4 ALL SENSIBLE CAPACITY Central Environmental Systems 530.18-TG1 COOLING CAPACITIES - 4 TON (DHB / DUC048) Air On Temperature of Air on Condenser Coil Evaporator 85°F MillMaganntgagennelat4tEiN Powei Input KW Coil Total Dap) MBH Power Input' KW Sensible Capacityl MBHSensible Total Cap.1 MBH Power Input` KW Capacity'', MBH „ai SM -V" WB op Entering Dry Bulb °F Enterin. Dry Bulb, °F 86,,83 , 71 , 80 77 _ 74 71 , 68 86 133 INS 77 74 71 68 2000 72 67 62 57 58 55 51 51 4.2 4.0 4.0 3.9 42 50 51 *51 37 47 51 51 32 42 50 50 26 37 45 45 - 32 40 40 - 26 35 35 - - 30 29 57 54 50 49 5.3 5.2 52 5.1 42 47 50• • 48. 37 46 " 32 41 48 iF;iiag 26 36 43 43 - 31 37 38 - 26 33 32 - - 27 27 1800 72 67 62 57 57 54 50 50 4.1 4.0 3.9. 3.9 40 49 .... 5 35 45 & 1 30 40 48 49 25 35 44 44 - 30 39 40 - 26 34 35 - - 29 30 55 52 48 48 4.5 4,4 4A 4.3 39 47 ::: - 35 44 48 30 39 46 47 25 34 42 42 - 29 37 37 - 25 32 32 - - 27 28 :9 A Mg? 62 56 53 50 50 4.0 3.9 3.8 3.8 37 47 S ..,.::::......: .;:;!Stit 33 42 49 ;:::;50:ii 29 38 46 48 24 34 42 44 - 29 37 40 - 25 33 35 - - 29 31 54 lat:4,,Ang 48 46 4.4 42 4.2 37 44 4.48 •,: : 33 41 .. 28 Alaii::: 45 45 24 32 40 41 - 28 36 37 - 24 32 33 - - 28 28 1400 72 67 62 57 53 50 47 47 4.0 3.9 38 3.8 34 42 47 30 38 45 ::::::•47:"•:* 26 35 42 44 22 31 38 40 - 27 34 36 - 23 30 32 - - 27 29 51 48 44 43 4.3 4.3 42 4,1 34 42 44 , 30 38 42 , " 26 34 41 41 23 30 38 39 - 27 34 35 - 23 30 31 - - 26 27 1200 72 67 62 57 51 48 45 45 3.9 3.9 3.8 3.7 30 38 .45 27 34 41 43 24 31 38 40 20 28 34 36 - 24 31 _ 33 - 21 28 _ 30 - - 24 26 _ 48 46 41 41 4.2 4.2 4.1 4.0 31 38 440 . 28 35 40 24 32 39 39 21 28 35 36 - 25 32 33 - 22 29 29 - - 25 26 Air On Evaporator Coil Temperature of Air on Condenser Coil 105°F 115°F Total, • Cap.' MBH Powei Input KW Sensible Capacity'', MBH Total Cap.1 MBH Powex Input KW Sensible Capanyl, MBH CFM WB °F Entering Dry Bulb, °F Entering Dry Bulb. °F 86 83 80 , 77 74 , 71 , 68 86 83 80 77 74 71_ 68 2000 72 67 62 57 54 49 46 45 4.7 4.6 4.6 4.5 41 44 ' - 36 43 45.......44......, ,'ii;;;;Oil•;; 31 40 26 35 39 39 - 30 34 34 - 24 29 29 - - 24 24 51 454.939,,,,,,36 42 41 5.1 4.9 4.8 40 42 35 30 40 25 33 35 35 - 28 30 30 - 23 25 25 - - 20 20 1800 72 67 62 57 53 48 44 44 4.7 4.6 4.5 4.5 38 43 ,., 44 :::i': 34 42 44 •:::- 29 38 43 43 i 24 33 38 38 - 28 34 34 - 23 29 29 - - 24 24 50 44 41 40 5.1 4.9 4.9 4.8 37 pp • ' 33 pp -::„i;i:::i ' 28 36 pp :i:i,••40,•,:] 23 32 35 35 - 27 30 30 - 22 26 26 - - 21 21 1600 72 87 62 57 52 47 44 43 4.6 4.5 44 4.4 36 41 44 ;JIIi!:ii... 32 4p .44 ;4 27 35 42 42 23 31 38 38 - 27 33 34 - 23 29 29 - - 25 25 49 .43 40 40 5.0 4.8 4.8 4,7 • 35 3! 4Q 31 38 4G39 •• 26 34 39 22 30 35 35 - 25 30 30 - 21 26 26 - - 22 22 1400 72 67 62 57 49 45 42 41 I` 4.5 4.5 4.4 4.3 33 42 .• 4 41 29 36 40 ..4iig 25 32 38 38 21 29 34 35 - 25 31 31 - 21 27 27 - - 23 23 46 41 38 37 5.0 4.8 4.7 4/ 31 pp :;:i.,..,,,..-:. :;:;•;•3S 37 27 .34 36 3? 24 31 35 35 20 27 31 31 - 23 27 27 - 19 24 24 - - 20 20 1200 72 67 62 57 46 42 39 38 4.4 4.4 4.3 4.2ftia 29 36 •M!...•:, 26 33 37 23 29 35 35 19 26 31 32 - 23 28 28 - 19 25 25 - - 21 22 44 38 36 35 4.9 4.7 4.6 4.6 27 34 '"S A '7. 24 30 34 21 27 31 31 17 24 28 28 - 20 24 24 - 17 21 21 - - 18 18 These capacities are gross ratings. For net capacity, determine the KW of the supply air blower motor from the Blower Performance Table, multiply this value by 3.415 MEN/ KW to detemine the motor heat, and dedud this heat from the gross capacity of the unit. 2 These ratings indude the compressor and the condenser fan motors but not the supply air blower motor. The total condenser fan motor power input 2 0.46 KW, Refer to the Blower Performance Table for the KW of the supply air blower motor. VW:M.3 a$:Ati NOMINAL RATING Central Environmental Systems ALL SENSIBLE CAPACITY 5 530.18-TG1 COOLING CAPACITIES - 5 TON (DHB / DUC060) Air On Temperature of Air on Condenser Coil Evaporator 85°F iiiintininkienniaMilliiii:WNIENNOt Power Input2 KW Coil Total Cap.1 MBH Power Input KW Sensible Capac tyl, MBH Total Cap.1 MBH POWEf Input' KW Sensible Capac'ty1. MBH CFM WB °F Entering Dry Bulb, °F Entering Dry Bulb, °F 86 83 80 77 74 71 68 86 83 NW: 77 74 71 68 2500 72 67 62 57 70 66 63 62 5.0 4.9 4.9 4.8 51 59 , 3 45 57 -....••••••••••••• 83 38 51 60 60 32 44 54 54 - 38 48 49 - 34 41 41 - - 35 35 69 65 61 59 5.3 5.2 5.2 5.1 52 57 58 :01:: 45 56 57 Itig 38 51 55 56 32 44 52 52 - 38 46 46 - 31 39 39 - - 32 32 2250 72 67 62 57 69 65 62 61 4.9 4.9 4.8 4.8 49 58 62 .;.. 64 42 55 2• 61 36 49 59 59 30 42 53 53 - 36 47 47 - 30 41 41 - - 34 35 67 64 59 58 5.2 5.2 5.1 5.1 49 55 59 60::'. 43 54 56 "f$0,, ' 37 48 54 55 31 42 51 51 - 35 45 45 . - 30 39 39 - - 33 33 Kin.' 72 , ititia 57 68 64 60 60 4.9 4.8 4/ 4/ 46 57 60.....'.....:":1: 00, 40 52 :: 5).58 35 46 56 29 41 51 53 - 35 45 48 - 30 40 42 - - 34 37 66w, ,:',W 'VW 58 58 w.,5,2 w ...`11 51 5.0 46 55 :...:v.":...::.. 58:', 40 51 56 ii58g 35 ., MI 54 54 29 40 50 50 - 35 45 45 - 30 39 39 - 34 34 1750 72 67 62 57 66 62 .59 58 4.8 4.8 4.7 4/ 42 53 i:i:rit: 37 48 56 58 32 43 52 54 27 38 47 50 - 33 42 45 - 28 38 40 - - 33 35 64 60 56 55 5.2 5.1 5.0 5.0 43 §g 56 38 49 54 65 33 44 52 52 29 39 49 49 - 35 44 44 - 30 39 39 - - 34 34 1500 72 67 62 57 64 61 57 56 4.8 4.8 4,7 4.6 38 48 54 iiiii• 34 44 52 54 30 40 48 50 26 35 44 46 - 31 40 42 - 27 35 37 - - 31 33 61 58 54 53 5.1 5.1 5.0 4.9 41 51 52 93 36 47 51 32 45 50 51 51 28 38 47 47 - 34 43 43 - . 30 39 39 - - 35 35 Air On Evaporator Colt Temperature of Air on Condenser Coil 105°F 115°F Total Cap.1 MBH Power Input2 KW Sensible Capadtyl, MBH Total Cap.1 MBH Power Input' KW Sensible Capacity1, MBH CFM WB °F Entering Dry Bulb °F Entering Dry Bulb, °F 88 83 80 77 74 71 68 86 83 80 77 , 74 71 , 68 2500 72 67 62 57 64 60 55 53 5.8 5,6 5.5 5.5 50 52 .-55 ...' - 44 51 8 W: 38 50 52 52 31 43 47 47 - 36 40 41 - 30 33 34 - - 27 27 60 54 48 48 6.2 5.9 5.8 5.8 46 47 48 44 45 48 Att, 37 45 46 47 31 41 42 42 - 35 36 36 - 28 29 29 ' - -- 23 23 225067 72 62 57 63 59 53 53 5.7 . 5.6 5.5 5.4 48 51 58:: 42 51 -'77 .:•:-:53 36 47 51 52 30 41 46 46 - 35 41 41 - 29 35 35 - - 28 29 59 54 48 47 6.1 5.9 58 5/ 45 46 ''.7 41 45 ... 47. 4 35 44 45 46 29 39 42 42 - 33 36 36 - . 27 30 30 - - 24 24 2000 72 67 62 57 62 57 52 52 5.7 5.5 5.4 5.4 45 50. S 62 39 1'4 52 :11: 34 44 50 51 28 39 46 46 - 33 41 41 - 28 36 36 - - 30 30 58 52 47 46 6.1 5.8 5/ 5/ 44 45. 47'':': 48: 38 45 46 1148I 33 42 45 45 27 37 42 42 - 32 36 37 - 26 31 32 - - 26 26 1750 72 67 62 57 60 . 55 51 50 5.6 5.5 5.4 5.3 41 48 " - .::::50...A]tef.U. 36 46 ,....§9....... 32 42 49 49 27 37 44 44 - 32 39 39 - 27 34 34 - - 30 30 55 49 45 44 6.0 5.8 5.7 5.6 40 43 :'45"l......44....... .::' 35 43 44.. 30 39 43 43 25 34 38 39 - 29 33 34 - 24 28 29 - - 24 24 1 500 72 67 62 57 57 52 49 48 5.5 5.4 5.3 5.2 38 46 ;*:49' iiiliWii;Aiiiiiii 34 43 47 30 39 45 45 25 35 41 41 - 30 37 37 - 26 33 33 - - 29 28 52 47 43 42 5.9 5.7 5.6 5.5 36 41 iiii::43 ii42iiiiii 31 39 42 ilii4*iii 27 35 39 39 23 31 35 35 - 26 30 31 - 22 26 27 -. - 22 22 1These capacities are gloss ratings For net capacity, determine the KW d the supply ar blower motor from the Blower Performance Table, multi* this value by 3.415 MBH / KW to determine the motor heat, and deduct this heat from the gross capacity of the unit. 2These ratings Include the compressor and the condenser fan motors but not the supply air blower motor. The total condenser fan motor power input is 0.47 KW. Refer to the Blower Performance Table for the KW of the supply air blower motor. ,Viog NOMINAL RATING 6 ALL SENSIBLE CAPACITY Central Environmental Systems 530.18 -TG 1 COOLING CAPACITIES - 6 TON (DHB / DUC076) Air On Evaporator Coil Tem. t ature of Air on Condenser Coil 85°F :WPin:.r.ANNOMN:',..,,, Total Cap.1 Total Cap.1 MBH Powkr Input' KW Sensible Capac tyl, MBH Total Powej Cap.1 Input MBH KW Sensible Capacity/, MBH CFM CFM WB °F Enteri D Bulb °F Enterin. D Bulb °F 80 86 :3 ;0 4 1 .; 80 77 74 71 68 2750 72 67 62 57 93 85 79 76 6.9 6.6 6.5 64 60 72 74 •iWli.gi.e.i; 52 65 71 44 57 68 71 37 • 50 42 61 54 64 57 - 35 47 50 - - 40 42 87 81 71 69 7.3 7.0 6.8 6/ 59 66 68 ..:•it9A6tg: 51 64 65 43 56 64 67 36 48 59 60 s- 41 52 53 - 34 44 45 - - 37 38 •• 4'' • - AO" M 72 . "'::":84 62 57 91 77 74 6.8 6.5 6.4 83 59 71 ip.....,.......71......... 74 51 64 74 44 57 6861 71 37 - 50 42 54 64 57 - 35 47 50 - - 40 42 . 86 ..t..„7...,?„..... 31;iiii.nr 70 68 1 6.7 6.6 58 65 ...g.., 4.66.Z 50 63 s.s.... iieii 43 ff402 64 67 36 48 59 60 - 41 52 53 - 34 44 45 - - 37 38 2300 72 67 62 57 89 83 75 72 6.7 6.5 6.3 6.2 58 70 72 IiiNi!i!lifli' 51 63 71 44 56 68 71 37 - 50 43 61 54 64 57 - 36 48 50 - - 41 44 85 79 70 68 7.2 6.9 6.6 6.5 56 65 67 giiiC.ifill; 49 62 66 42 55 65 66 36 48 58 60 - 41 51 53 • 34 45 48 - - 38 39 2100 72 67 62 57 87 82 73 69 6.7 6.4 6.2 6.1 54 66 68 ,Pii4-::::•':;i 48 60 66 42 . 54 64 36 48 59 62 - 42 53 56 - 36 47 50 -84 - 41 44 77 68 66 7.1 6.9 6.6 6.5 54 64 ss ''*i, •i:':, 47 59 64 ,:p.-.i:i:ii ]:,,:l.i:•::,: 41 52 62 63 35 46 55 57 - 40 49 51 - 33 42 44 - - 36 38 1900 72 67 62 57 85 80 71 68 6.6 6.4 62 6.0 51 63 66 15:i..6:*, 46 57 65 40 51 61 64 34 46 55 59 - 40 50 53 - 34 44 47 - - 38 42 80 74 65 64 7.1 6.8 6.6 6 5 50 61 5 .. . 44 55 63 i::;:, -.:':K .:::::. ,::::: 38 49 58 60 33 43 52 54 - 38 46 48 - 32 41 42 - - 35 • 37 Air On Evaporator Coil Temperature of Air on Condenser Coil 105°F 115°F Total Cap.1 Power Input2 Sensible Capacityl, MBHTotal Cap.1 Powei Input` Sensible Capacityl, MBH CFM WB °F Entering Dry Bulb, °F Entering Dry Bulb, °F 86 83 80 77 , 74 71 , 68 86 83 80 77 74 71 68 MBH KW MBH KW 72 82 7.8 58 50 42 , 35 - - - 80 ; 8.1 57 , 49 40 , 32 • - - 2750 67 74 7.5 65 63 55 47 40 33 - 69 7.8 64 61 53 45 36 28 - 62 65 72 64 58 51 43 36 64 7.5 84' -54 63 54 46 37 30 57 65 7.2 - ,... 64 58 51 43 36 64 7.5 - ' 62 53 44 36 29 72 81 7.8 57 50 42 35 - - - 78 8.0 57 49 40 32 - - - 2500 67 74 7.5 63 s1 54 47 40 33 - 68 7.7 61 so 52 44 36 28 - 62 65 72 65 65 64 57 50 42 35 63 74 3 - 61 52 44 36 30 57 65 72 6565 64 58 51 43 36 63 7.4 63: i,,,63 60 52 43 35 29 72 80 7.6 54 47 41 34 - - - 75 8.0 ' 61 45 38 32 - - - 2300 67 74 7.3 s3 59 52 45 39 32 - ' 67 7.7 57 56 49 43 36 30 - 62 65 7.0 65 65"•,•: •ss:::::: 61 55 48 41 35 59 74 5' 5' 57 51 44 -38 31 57 65 7.0 65 62 56 49 42 36 59 7.4 6. ION 57 50 44 37 30 72 79 7.6 51 45 39 33 - - - 74 8.0 49 43 37 31 - - - 2100 67 73 7.3 60 -.. 56 • - 50 44 38 32 - 64 7.7 54 53 47 41 35 29 - 62 62 6.9 58 52 46 40 34 56 7.3 56 5: 54 48 42 36 30 57 62 6.9 6 59 53 47 41 35 57 7.3 , 54 48 42 36 30 72 76 7.4 48 42 37 31 - - - 72 7.9 46 40 35 29 - - - 1900 67 69 7.2 57 53 47 41 36 30 - 63 7.6 53 50 44 38 33 27 - 62 57 , 60 1 59 6.9 6.8:M641 80 58 55 56 49 50 43 44 38 39 32 33 55 55 7.3 7.2 ::::,:i 54 .::::: • :::: ::::1: 51 51 45 45 40 40 34 34 28 28 mese capacities are gross ratings. For net capacrt% determine the KW c the supply air bower moto from the Blower Performance Tab, multiply this value by 3416 MBH/ ION to determine the motor heat, and deduct this heat from the gross capacity of the unit. 2 These ratings include the compressor and the condenser fan motors but not the supply air blower motor. The total oondenser tan motor pow input is 0.54 KW. Refer to the Blower Performance Table for the KW of the supply air blower motor. ige.'Ssa NOMINAL RATING Central Environmental Systems ALL SENSIBLE CAPACITY 7 530.18-TG1 SUPPLY AIR BLOWER PERFORMANCE - DUC060 & 076 with Belt -Drive -SIDE DUCT APPLICATIONS (230/460/575 VOLTS MODEL DUC AIR FLOW CFM Available External Static Pressure - IWG" 0.20 0.30 0.40 0.50 0.60 0.70 0.80 RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts 060 2500 1059 1560 1077 1590 1095 1630 1114 1650 1134 1660 1158 1685 1181 1720 2400 1032 1405 1054 1470 1074 1525 1094 1560 1116 1595 1140 1620 1167 1640 2300 1005 1260 1024 1275 1049 1370 1069 1440 1090 1475 1116 1505 1142 1535 2200 980 1160 1002 1170 1022 1190 1044 1250 1066 1350 1090 1410 1117 1440 2100 930 1060 957 1070 983 1080 1010 1100 1039 1160 1064 1260 1092 1340 2000 877 950 908 975 941 1000 976 1020 1009 1050 1040 1100 1070 1225 1900 - - - - 894 885 940 940 980 980 1014 1020 1047 1095 1800 - - - - 855 815 903 860 950 905 988 940 1022 970 1700 - - - - - - 884 815 925 850 964 880 1001 910 1600 - - - - - - 864 770 908 805 948 835 987 870 1500. - - - - - - - - 882 740 926 780 965 830 MODEL DUC AIR FLOW CFM Available External Static Pressure - IWG* 0.90 1.00 1.10 1.20 1.30 1.40 1.50 RPM Watts RPM Watts RPM , Wa_ft RPM Watts RPM Watts RPM Watts RPM Watts 060 2500 - - - - - - - - - - - - - - 2400 1193 1665 - - - - - 2225 - - - - - - 2300 1170 1580 1202 1620 - - - - - - - - - - 2200 1148 1480 1180 1530 - - - - - • - - - - 2100 1121 1385 1155 1425 1190 1475 - - - - - - - - 2000 1100 1285 1133 1340 1169 1385 1205 1445 - - - - - - 1900 1079 1180 1110 1240 1143 1280 1178 1330 1222 1375 - - - - 1800 1058 1060 1090 1136 1122 1190 1158 1240 1196 1295 - - - - 1700 1035 960 1071 1030 1103 1100 1134 1140 1164 1175 1197 1205 - - 1600 1020 900 1056 965 1088 1035 1118 1065 1145 1105 1170 1130 1198 1150 1500 1004 660 1038 _ 880 , 1070 925 1101 980 1130 1045 1158 1075 1184 1110 NOTE FOR 208 VOLTS, MULTIPLY VALUES BY 0.96. . 'INCLUDES ALLOWANCES FOR A WET EVAPORATOR. COM, 1' FILTERS, AND THE HEAT EXCHANGERS. REFER TO THE STATIC RESISTANCES TABLE FOR RESISTANCE VALUES ON APPUCATIONS OTHER THAN GAS / ELECTRIC UNITS WITH SIDE DUCT AIRFLOWS. DUC076 - SIDE DUCT APPLICATIONS (230/460/575 VOLTS) MODEL DUC AIR FLOW CFM Available External Static Pressure - IWG' 0.20 0.30 0.40 0.50 0.60 0,70 0.80 RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts 076 3200 1150 2325 1182 2425 1212 2525 - - - • - - - - 3000 1100 2010 1129 2090 1157 2150 1185 2225 1215 2290 1242 2360 - - 2800 1045 1700 1074 1780 1102 1850 1131 1940 1160 2025 1190 2075 1217 2130 2600 985 1425 1015 1475 1045 1540 1075 1630 1103 1715 1135 1760 1163 1825 2400 930 1240 958 1300 990 1350 1020 1400 1051 1430 1081 1490 1111 1600 2200 - - 905 1070 933 1160 965 1210 997 1250 1028 1285 1060 1325 2000 - - - - - - 919 1025 950 1100 982 1130 1014 1160 1800 - - - - - - - - 909 925 939 1005 968 1030 MODEL DUC AIR FLOW CFM Available Edema! Static Pressure - IWG' 0.90 1.00 1.10 1.20 1.30 1.40 1.50 RPM Watts RPM Watts RPM , Watts RPM Watts RPM Watts RPM Watts RPM Watts 076 3200 - - - - - - - - - - - - - 3000 - - - - - - - - - - - - - - 2800 1245 2190 - - - - - - - - - - - . - 2600 1193 1920 1222 1990 1250 2060 - - - - - - 2400 ' 1142 1675 1173 1730 1205 1800 1234 1885 - - - - 2200 1090 1380 1124 1450 1155 1550 1186 1640 1217 1710 1249 1775 - 2000 1045 1175 1077 1200 1109 1275 1140 1360 1170 1460 1205 1545 1235 1600 1800 998 1050 1028 106Q 1058 1060 1087 1075 1118 1150 1148 1250 1176 1360 NOTE: FOR 208 VOLTS, MULTIPLY VALUES BY 0.95. *INCLUDES ALLOWANCES FOR AWET EVAPORATOR COIL, 1FILTERS, AND THE HEAT EXCHANGERS. REFER TO THE STATIC RESISTANCES TABLE FOR RESISTANCE VALUES ON APPLICATIONS OTHER THAN GAS / ELECTRIC UNITS WITH SIDE DUCT AIRFLOWS. 8 Central Environmental Systems 530.18-TG1 SUPPLY AIR BLOWER PERFORMANCE - DUC036, 048, 060, 076 with Direct -Drive NOTE FOB 208•VOLTS, MULTIPLY VALUES BY 0.95. "INCLUDES ALLOWANCES FOR A WET EVAPORATOR COIL 1' FILTERS, AND THE HEAT EXCHANGERS REFER TO THE STATIC RESISTANCES TABLE FOR RESISTANCE VALUES ON APRLICATIONS OTHER THAN GAS / ELECTRIC UNITS WITH SIDE DUCT AIRFLOWS. FACTORY -INSTALLED OPTION BELT DRIVE BLOWER: Adjustable belt -drive blower, providing maximum flexibility to handle many airflow requirements, is available on 5 and 6 ton, 3-phase models. FIELD -INSTALLED ACCESSORIES SINGLE INPUT ELECTRONIC ENTHALPY ECONOMIZER - Includes a slide -in / plug-in damper assembly with fully modulating spring return motor actuator capable of introducing up to 100% outdoor air, one outdoor air electronic enthalpy sensor and a rain hood with filters. The rain hood is painted to match the basic unit and must be field -assembled before installation. Economizer dampers are 2% low leakage type. DUAL INPUT ELECTRONIC ENTHALPY ECONOMIZER - Includes the same damper system and rain hood with filters as described for a single enthalpy economizer except this accessory contains two enthalpy sensors. it uses a differential enthalpy control that compares the outdoor air versus the return air. The logic module then optimizes the economizer operation for additional savings over the single input economizer. MOTORIZED AIR DAMPER - Includes slide -in /plug-in damper assembly with 2 -position spring -return motor actuator and a rain hood with permanent -type filters. The outdoor air dampers open when the indoor fan motor is energized. The rain hood is shipped knocked down and must be field assembled. BAROMETRIC RELIEF/FIXED OUTDOOR AIR INTAKE AIR DAMPER - A dual function device that consists of a rain hood with a bird screen and a flexible damper. It provides either of the following: 1) a fixed outdoor air intake on units less economizer or 2) barometric relief or units with economizer. The rain hood is fully assembled, painted to match the basic unit and ready for installation. ELECTRIC HEATERS - Include nickel chromium elements, a terminal block, fuses (where required by UL), all the necessary connectors and hardware. All heaters utilize single point power supply hookup. Capacities from 5 KW thru 30 KW heating are available. FUSE BLOCK KITS - These kits have a fuse box with a fuse block and fuses. They're available for all 460-3-60 volt heaters and 208/230-3-60 volt heaters 7 KW and smaller. OUTDOOR THERMOSTAT- A24 -volt thermostat providing two stages of control for units equipped with electric heat accessories. ROOF CURB - This 14" high full perimeter roof curb is shipped knocked down for field assembly and contains duct supports that can easily be shifted forthe desired unit duct arrangement. No insulated deck is required because the unit underside is insulated. START ASSIST KIT - Provides increased starting torque for single phase units in areas with low voltage conditions. It contains a 12.5 OHM PTCR temperature resistor with a support clip and hardware for mounting. LOW AMBIENT KIT - A head pressure controller maintains stable system operation by reducing the speed of the condenser fan motor when the outdoor temperature is between 45 and 0°F. Condenser fan motors with ball bearings and heavier windings are also available for these low ambient applications. ANTI -RECYCLE TIMER - A timer to prevent the unit compressor from short cycling. It assures a 5 -minute off -time between compressor. cycles. PROPANE CONVERSION KIT - Converts a gas-fired heater from natural gas to,propane. It contains main burner orifices, a pilot orifice and a regulator spring. LOW NOx KIT (natural gas furnaces only) - Contains five stainless steel expanded metal sheets for mounting into the heat exchanger tubes to meet the California low nitrous oxide emission requirements. HIGH ALTITUDE CONVERSION (NATURAL AND PROPANE) - Provides orifices for proper furnace operation at altitudes up to 6000 feet. For propane applications, the propane conversion kit will also be required. GAS PIPING - This kit contains 1/2" pipe nipples, fittings and gas cock (including panel access gaskets) required for bottom gas supply connection with external shut-off. OUTDOOR COIL GUARD - Consists of grille -type sections for installation over the outdoor coil to protect itfrom damage. WALL THERMOSTAT - The units are designed to operate with 24 -volt electronic and electro -mechanical thermostats. All units can operate with single stage heat / single stage cool thermostats - with or without the economizer. Central Environmental Systems 9 MODEL DU SOTO MOTOR Available External Static Pressure - IWG* 020 0.30 0.40 0.50 ,0.60 0.70 0.80 • 0.90 1.00 CFM Watts_ CFMiWatts_ Cadahatts CFM Watts., CFM Watts CFM Watts CFM Watts CFM Watts CFM Watts HI - - - - 1699 825 1650 785 1570 755 1430 725 1360 700 1280 680 1180 655 036 MED 1684 800 1631 780 1582 750 1524 720 1410 690 1324 650 1260 630 1185 610 '1100 590 LOW 1487 710 1464 690 1421 670 1367 650 1315 620 1248 605 1185 590 1110 570 1020 545 HI 1996 960 1933 936 1868 910 1795 880 1722 845 1635 820 1544 790 1419 765 1300 740 048 MED 1804 838 1765 810 1714 785 1650 765 1589 735 1508 705 1407 675 1306 645 1195 625 LOW 1681 760 1640 738 1604 715 1541 695 1490 670 1416 645 1337 620 1230 595 1120 575 HI 2400 1155 2338 1125 2274 1095 2167 1045 2096 1010 1990 980 1887 945 1771 905 1629 855 060 MED. 2290 1105 2214 1065 2145 1030 2071 990 1990 950 1911 920 1828 885 1724 835 1604 798 LOW 2150 1020 2100 990 2029 950 1965 910 1905 880 1816 838 1724 800 1644 770 1531 710 076 HI 2461 1480 2402 1440 2361 1395 2260 _1350 2178 1305 2101 1260 2000 1205 1914 1155 1830 1110 NOTE FOB 208•VOLTS, MULTIPLY VALUES BY 0.95. "INCLUDES ALLOWANCES FOR A WET EVAPORATOR COIL 1' FILTERS, AND THE HEAT EXCHANGERS REFER TO THE STATIC RESISTANCES TABLE FOR RESISTANCE VALUES ON APRLICATIONS OTHER THAN GAS / ELECTRIC UNITS WITH SIDE DUCT AIRFLOWS. FACTORY -INSTALLED OPTION BELT DRIVE BLOWER: Adjustable belt -drive blower, providing maximum flexibility to handle many airflow requirements, is available on 5 and 6 ton, 3-phase models. FIELD -INSTALLED ACCESSORIES SINGLE INPUT ELECTRONIC ENTHALPY ECONOMIZER - Includes a slide -in / plug-in damper assembly with fully modulating spring return motor actuator capable of introducing up to 100% outdoor air, one outdoor air electronic enthalpy sensor and a rain hood with filters. The rain hood is painted to match the basic unit and must be field -assembled before installation. Economizer dampers are 2% low leakage type. DUAL INPUT ELECTRONIC ENTHALPY ECONOMIZER - Includes the same damper system and rain hood with filters as described for a single enthalpy economizer except this accessory contains two enthalpy sensors. it uses a differential enthalpy control that compares the outdoor air versus the return air. The logic module then optimizes the economizer operation for additional savings over the single input economizer. MOTORIZED AIR DAMPER - Includes slide -in /plug-in damper assembly with 2 -position spring -return motor actuator and a rain hood with permanent -type filters. The outdoor air dampers open when the indoor fan motor is energized. The rain hood is shipped knocked down and must be field assembled. BAROMETRIC RELIEF/FIXED OUTDOOR AIR INTAKE AIR DAMPER - A dual function device that consists of a rain hood with a bird screen and a flexible damper. It provides either of the following: 1) a fixed outdoor air intake on units less economizer or 2) barometric relief or units with economizer. The rain hood is fully assembled, painted to match the basic unit and ready for installation. ELECTRIC HEATERS - Include nickel chromium elements, a terminal block, fuses (where required by UL), all the necessary connectors and hardware. All heaters utilize single point power supply hookup. Capacities from 5 KW thru 30 KW heating are available. FUSE BLOCK KITS - These kits have a fuse box with a fuse block and fuses. They're available for all 460-3-60 volt heaters and 208/230-3-60 volt heaters 7 KW and smaller. OUTDOOR THERMOSTAT- A24 -volt thermostat providing two stages of control for units equipped with electric heat accessories. ROOF CURB - This 14" high full perimeter roof curb is shipped knocked down for field assembly and contains duct supports that can easily be shifted forthe desired unit duct arrangement. No insulated deck is required because the unit underside is insulated. START ASSIST KIT - Provides increased starting torque for single phase units in areas with low voltage conditions. It contains a 12.5 OHM PTCR temperature resistor with a support clip and hardware for mounting. LOW AMBIENT KIT - A head pressure controller maintains stable system operation by reducing the speed of the condenser fan motor when the outdoor temperature is between 45 and 0°F. Condenser fan motors with ball bearings and heavier windings are also available for these low ambient applications. ANTI -RECYCLE TIMER - A timer to prevent the unit compressor from short cycling. It assures a 5 -minute off -time between compressor. cycles. PROPANE CONVERSION KIT - Converts a gas-fired heater from natural gas to,propane. It contains main burner orifices, a pilot orifice and a regulator spring. LOW NOx KIT (natural gas furnaces only) - Contains five stainless steel expanded metal sheets for mounting into the heat exchanger tubes to meet the California low nitrous oxide emission requirements. HIGH ALTITUDE CONVERSION (NATURAL AND PROPANE) - Provides orifices for proper furnace operation at altitudes up to 6000 feet. For propane applications, the propane conversion kit will also be required. GAS PIPING - This kit contains 1/2" pipe nipples, fittings and gas cock (including panel access gaskets) required for bottom gas supply connection with external shut-off. OUTDOOR COIL GUARD - Consists of grille -type sections for installation over the outdoor coil to protect itfrom damage. WALL THERMOSTAT - The units are designed to operate with 24 -volt electronic and electro -mechanical thermostats. All units can operate with single stage heat / single stage cool thermostats - with or without the economizer. Central Environmental Systems 9 530.18-TG1 STATIC RESISTANCES DESCRIPTION RESISTANCE, IWG CFM 1000 12.00 1400 1600 1800 2000 2200 2400 2600 2800 3000 Economizer/Motorized Damperl,3 0.07 0.08 0.09 0.11 0.13 0.15 0.17 0.20 0.23 0.26 0.30 Electric Heaters1 5-15 KW 0,04 0.05 0.06 0.07 0.08 0.10 0.12 0.14 0.16 0.19 0.22 20 - 30 KW 0.06 0.07 0.08 0.09 0.11 0.13 0.15 0.17 0.20 0.23 0.26 Bottom Duct Connectionst 0.06 0.07 0.08 0.09 0.10 0.11 0.12 0.14 0.16 0.19 0.22 Coolina OnIv2 0.08 0.10 0,12 0d4 0.16 0.18 0.20 0.23 0.26 0.29 0.32 Deduct these resistance values from the avataae external static pressure shown in the respective Blower Performance Table. 2Add these resistance values to the available static resistance in the respective Blower Performance Table. 3The pressure thru the economizer is greater for 100% outdoor air than for 100% return air. If the resistance of the return air duct system is less than 0.25 IWO, the unit wtl deliver less CFM during f uI economizer operation. MOTOR AND DRIVE DATA - Belt -Drive Blower MODEL • BLOWER RANGE (RPM) MOTOR' ADJUSTABLE MOTOR PULLEY FIXED BLOWER PULLEY BELT HP RPM FRAME SIZE SERVICE FACTOR PITCH DIA' (in.) BORE (in.) PITCH DIA. (In 1 BORE din) PITCH LENGTH lin 1 DESIG- NATION DHB /DUC 060 850 - 1220 1-1/2 1725 56 1.15 2.4 - 3.4 7/8 5.2 1 37,3 A36 DHB / DUC 076 900 - 1250 1-1/2 1725 56 1.15 2.8 - 3.8 7/8_ _ 5 2 1 37.3 A36 *Al motors have sold bases and are inherenty protected These motors can be selected to operate into their service factor because they are located in the moving air, upstream of any heating device. tLtL:1 HIL:AL DATA - Basic Units with Direct -Drive MODEL DHB DUC POWER SUPPLY VOLTAGE LIMITATIONS (SEE NOTE 1) COMPRESSOR COND. , FAN MOTOR, FLA SUPPLY AIR BLOWER MOTOR , FLA TOTAL UNIT AMPACITY, AMPS MAX. FUSE SIZE,BREAKER (SEE NOTE 2) AMPS MAX. HACR SIZE, AMPS MIN. WIRE SIZE, AWG (SEE NOTE 31 MIN. MAX. RLA LRA 208/230-3-60 208/230-1-60 187 253 19.2 87 2.3 4.4 30.7 45 45 8 036 _ 208/230-3-60 187 253 14.1 110 2.3 4.4 24.3 35 35 10 575-3-60 460-3-60 414 504 7.1 54 1.4 2.2 12.5 15 15 14 208/230-3-60 i 575-3-60 518 630 5.8 44 1.4 2.2 10.9 15 - 14 460-3-60 208/230-1-60 187 253 23.1 105 2.3 5.0 36.2 50 50 8 048 208/230-3-60 187 253 14.7 130 2.3 5.0 25.7 40 40 10 460-3-60 414 504 7.1 64 1.4 2.2 12.5 15 15 14 575-3-60 518 630 6.4 52 1.4 2.2 11.6 15 - 14 208/230-1-60 187 253 28.2 135 2.3 6.6 44.2 70 70 6 060 208/230-3-60 187 253 16.7 150 2.3 6.6 29.8 45 45 10 460-3-60 414 504 9.6 73 1.4 3.3 16.7 25 25 10 575-3-60 518 630 8.3 59 1.4 3.3 15.1 20 - 12 208/230-3-60 187 253 28.2 220 2.3 6.8 40.8 50 50 6 076 460-3-60 414 504 14.1 108 1.3 3.6 20.8 25 25 10 575-3-60 518 630 11.5 88 1.3 3.6 17.9 20 - 12 NOTES: 1. Utilization Range 'A' in accordanoe with ARI Standard 110. 2. Dual element, time delay type. ELECTRICAL DATA - Basic Units with Belt -Drive 3. Based on 60'C copper conductors. MODEL DHB DUC POWER SUPPLY VOLTAGE LIMITATIONS (SEE NOTE 1) COMPRESSOR COND, FAN MOTOR, FLA SUPPLY AIR BLOWER MOTOR, FLA TOTAL UNIT AMPACITY AMPSAMPS MAX. FUSE SIZE, (SEE NOTE 2) MAX. HACR BREAKER SIZE, AMP$ MIN. WIRE SIZE, AWG (SEE NOTE 3) MIN. MAX. RLA LRA 208/230-3-60 187 253 16.7 150 2.3 6.0 292 45 45 10 060 460-3-60 414 504 9.6 73 1.4 3.0 16.4 25 25 10 575-3-60 518 630 8.3 59 1.4 2.4 14.2 20 - 12 208/230-3-60 187 253 28.2 220 2.3 7.3 41.3 50 50 6 076 460-3-60 414 504 14.1 108 1.3 3.7 21.0 25 25 10 575-3-60 518 630 11.5 88 _ 1,3 ' 3.0 __ 17 4 20 - 12 NOTES: 1. Uti¢etion Range -A' in accordance wth ARI Standard 110. 10 2. Dual element, tine delay type. 3. Based on SO'C copper conductors. Central Environmental Systems 530.18-TG1 ELECTRICAL DATA - Cooling / Electric HeatinDHB036 & 048) with Direct -Drive MODEL DNB POWER SUPPLY HEATER ACCESSORY MODEL NUMBER SUPPLY AIR BLOWER MOTOR FLA ELECTRIC HEATERS TOTAL UNIT AMPACITY AMPS MAX. FUSE SIZE' AMPS MAX. IZE HACK 2 BREAKER AMPS MIN. WIRE SIZES AWG KW STAGES TOTAL AMPS 20E04500506 4.0 1 19.1 30.7 45 45 8 2CE04500706 5.6 1 27.1 39.4 45 45 8 208-1-60 20E04501006 4.4 8.0 1 38.3 53.4 60 60 6 20E04501506 11.9 2 57.4 77.3 80 80 3 20E04502006 15.9_ 2 76.6 101.3 110 110 2 20E04500506 5.3 1 22.1 33.1 45 45 8 20E04500706 7.5 1 31.2 44.6 45 45 6 230-1-60 20E04501006 4.4 10.6 • 1 44.2 60.8 70 70 4 20E04501506 15.9 2 66.0 88.4 90 90 2 20E04502006 212 2 88.3 115.9 125 125 1 20E04500525* 4.0 1 11.0 24.3 35 35 10 20E04500725* 5.6 1 15.6 25.0 35 35 10 036 208-3-60 20E04501025 20E04501525 4.4 8.0 11.9 1 2 22.1 33.1 33.1 46.9 35 50 35 50 8 6 2CE04502025 15.9 2 44.2 60.8 70 70 4 20E04500525* 5.3 1 12.7 24.3 35 35 10 20E04500725* 7.5 1 18.0 28.0 35 35 10 230-3-60 20E04501025 4.4 10.6 1 25.5 37.4 40 40 8 20E04501525 15.9 2 38.2 53.3 60 60 6 2CE04502025 212 2 51.0 69.3 70 70 4 20E04500746* 6.8 1 8.2 13.0 15 15 14 460-3-60 20E04501046* 2.2 10.1 1 12.1 17.9 20 20 12 20E04501546* 13.6 1 16.4 23.3 25 25 10 20E04502046* 19.5 2 23.5 32.1. 35 35 8 20E04501058 10.6 1 102 15.5 20 - 12 575-3-60 20E04501558 2.2 15.9 1 15.3 21.9 25 - 10 2CE04502058 21.2 2 20.4 28.3 30 - 10 20E04500506 4.0 1 19.1 36.2 50 50 8 20E04500706 5.6 1 27.1 40.1 50 50 6 208-1-60 20E04501006 5.0 8.0 1 38.3 54.1 ' 60 60 6 20E04501506 11.9 2 57.4 78.0 80 80 3 20E04502006 15.9 2 76.6 102.0 110 110 2 20E04500506 5.3 1 22.1 36.2 50 50 8 2CE04500706 7.5 1 31.3 45.4 50 50 6 230-1-60 20E04501006 5.0 10.6 1 44.2 61.5 70 70 4 20E04501506 15.9 2 66.3 89.1 90 90 2 20E04502006 212 2 88.3 116.6 125 125 1 20E04500525* 4.0 1 11.0 25.7 40 40 10 20E04500725* 5.6 1 15.6 25.8 40 40 10 048 208-3-60 20E04501025 20E04501525 5.0 8.0 11.9 1 2 . 22.1 33.1 33:9 47.6 40 50 40 50 8 6 20E04502025 15.9 2 44.2 - 61.5 70 70 4 20E04500525' 5.3 1 12.7 25.7 40 40 10 20E04500725* 7.5 1 18.0 28.8 40 40 10 230-3-60 20E04501025 5.0 10.6 1 25.5 38.1 40 40 8 20E04501525 15.9 2 38.2 54.0 60 60 6 20E04502025 212 2 51.0 70.0 70 70 4 20E04500746* 6.8 1 8.2 13.0 15 15 12 460-3-60 20E04501046* 2 2 10.1 1 12.1 17.9 20 20 12 20E04501546* 13.6 1 16.4 23.3 25 25 10 20E04502046* 19.5 2 23.5 32.1 35 35 8 20E04501058 10.6 1 102 15.5 20 - 12 575-3-60 2CE04501558 2.2 15.9 1 15.3 21.9 25 - 10 20E04502058 21.2 2 20.4 28.3 30 - 10 1 Dual element, time delay type 2 Standard circuit breakers may be used in Canada and on applications over 60 amps where the heaters are separately fused. 3 Based on 60°C copper conductors (up to 100 amps max. or 75°C copper conductors (100 amps and over) • These electric heaters DO NOT lndude a fuse box. If a fuse box is required to meet a local code ((eg., Chicago), the following fuse block accessories are available for field installation, Central Environmental Systems Electric Heat Correction Factors Nominal Voltage Voltage ION Cap MUltipler 1.00 0.92 0,92 208 208 240 230 480 460 800 575 0.92 Fuse Block W6104700425 2FB04700546 208/240 Volts 460 Volts 11 530.18-TG1 tLI 1 Kl(AL DAIA - Cooling / Electric Heating (DHB060 & 076) with Direct -Drive MODEL DMB • POWER SUPPLY HEATER ACCESSORY MODEL , NUMBER SUPPLY AIR BLOWER MOTOR. FLA ELECTRIC HEATERS TOTAL UNIT AMPACITY AMPS • MAX. FUSESIZE SIZ AMPS MAX. HACK BREAKER AMPS MIN. WIN SIZE AWG KW STAGES TOTAL AMPS 20E04500506 4.0 1 19.1 44.2 70 70 6 2CE04500706 5.6 1 27.1 44.2 70 70 6 208-1-60 20E04501006 2CE04501506 6.6 8.0 11.9 1 2 38.3 57.4 56.1 • 80.0 70 90 70 90 4 3 • 20E04502006 15.9 2 76.6 104.3 110 110 2 2CE04503006 22.2 2 106.9 141.9 150 150 0 2CE04500506 5.3 1 22.1 44.2 70 70 6 2CE04500706 7.5 1 31,3 47.4 70 70 6 230-1-60. 20E04501006 20E04501506 86 10.6 15.9 1 2 44.2 66.3 63.5 91.1 70 100 70 100 4 2 20E04502006 212 2 88.3 118.6 125 125 1 20E04503006 29.6 2 123.3 162.4 175 175 00 20E04500525* 4.0 1 11.0 29.8 45 45 10 20E04500725* 5.6 1 15.6 29.8 45 45 10 208-3-60 2CE04501025 6 6 8.0 1 22.1 35.9 45 45 8 060 20E04501525 2CE04502025 11.9 15.9 2 2 33.1 442 49.6 63.5 50 70 50 70 6 4 2CE04503025 22.2 2 61.7 85.4 90 90 2 20E04500525* 5.3 1 12.7 29.8 45 45 10 20E04500725* 7.5 1 18.0 30.8 45 45 8 230-3-60 20E04501025 2CE04501525 6 6 10.6 15.9 1 2 25.5 38.2 40.1 56.0 45 60 45 60 6 4 20E04502025 21.2 2 51.0 72.0 80 80 3 2CE04503025 29.6 2 71.2 97.3 100 100 1 20E04500746* 6.8 1 82 16.7 25 25 10 20E04501046* 10.1 1 12.1 19.3 25 25 10 460.3-60 20E04501546* 3.3 13.6 1 16.4 24.6 25 25 10 20E04502046* 19.5 2 23.5 33.5 35 35 8 2CE04503046* 28.8 • 2 - 34.6 47.4 50 50 8 20E04501058 10.6 1 10.2 16.9 - 20 - 12 2CE04501558 15.9 1 15.3 23.3 25 - 10 575-3-60 2CE04502058 3'3 212 2 20.4 29.6 30 - 10 _ 2CE04503058 30.4 2 29.3 40.8 45 - 6 20E04500525* 4.0 1 11.0 40.8 50 50 6 20E04500725* 5.6 1 15.6 40.8 50 50 6 208-3-60 2CE04501025 2CE04501525 6 8 8.0 11.9 1 2 22.1 33.1 40.8 49.9 50 70 50 70 6 6 20E04502025 15.9 2 44.2 63.8 70 70 4 2CE04503025 22.2 2 61.7 85.6 90 90 2 20E04500525* 5.3 1 12.7 40.8 50 50 6 20E04500725* 7.5 1 18.0 40.8 50 50 6 230-3-60 2CE04501025 2CE04501525 6 8 10.6 15.9 1 2 25.5 38.2 40.8 56.3 50 70 50 70 6 4 076 2CE04502025 21.2 2 51.0 72.3 80 80 3 2CE04503025 29.6 2 71.2 97.5 100 100 1 20E04500746* ' 6.8 1 8.2 20.8 25 25 000mcD' 20E04501046* 10.1 1 12.1 20.8 25. 25 460-3-60 2CE04501546* 3.6 13.6 1 16.4 25.0 35 35 20E04502046* 19.5 2 23.5 33.9 35 35 2CE04503046* 28.8 2 34.6 47.8 50 50 2CE04501058 10.6 1 10.2 17.9 25 - 12 575-3-60 2CE04501558 2CE04502058 3 6 15.9 21,2 1 2 15.3 20.4 • 23.6 30.0 30 30 - - 10 10 2CE04503058 30.4 2 29.3 41.1 45 - 8 1 Dual element, time delay type 2 Standard arcut breakers may be used in Canada and on applbations over 60 amps where the heaters are separately fused. 3 Based on 60*C copper conductors (up to 100 amps max. or 75°C copper conductors (100 amps and over) • These electric heaters DO NOT include a fuse box if a fuse box is required to meet a boat code ((eg., Chicago), the following fuse block accessories are available for tied instaltatbn. 12 Electric Heat Correction Factors Nominal Voltage Votage KW Cap Mutipier 1.00 208 208 240 230 0.92 480 460 0.92 600 575 0.92 Fuse Bbck 2F804700426 2081240 Vots 2FB04700546 460 Vota Central Environmental Systems 530.18-TG1 ELECTRICAL DATA - Cooling / Electric Heating (DHB060 & 076) with Belt -Drive MODEL DHB POWER SUPPLY HEATER ACCESSORY MODEL NUMBER SUPPLY AIR BLOWER MOTOR FLA ELECTRIC HEATERS TOTAL UNIT AMPACITY AMPS MAX. FUSE SIZE1 AMPS MAX. SIZE "n0.12 BREAKER AMPS MIN WIR SIZE AWG KW STAGES TOTAL AMPS 2CE04500525* 4.0 1 11.0 29.2 45 45 10 2CE04500725* 5.6 1 15.6 29.2 45 45 10 208-3-60 2CE04501025 2CE04501525 6 0 8.0 11.9 1 2 22.1 33.1 35.1 48.9 45 50 45 50 8 6 2CE04502025 15.9 2 44.2 62.7 70 70 4 2CE04503025 22.2 2 61.7 84.6 90 90 3 2CE04500525* 5.3 1 12.7 29.2 45 45 10 2CE04500725* 7.5 1 18.0 30.1 45 45 8 230-3-60 2CE04501025 2CE04501525 6 0 10.6 15.9 1 2 25.5 38.2 39.4 55.3 45 60 45 60 8 4 060 2CE04502025 21.2 2 51.0 71.2 80 80 3 2CE04503025 29.5 2 71.2 96.5 100 100 1 2CE04500746* 6.8 1 8.2 16.4 25 25 10 2CE04501046* 10.1 1 12.1 18.9 25 25 10 460-3-60 2CE04501546* 3.0 13.6 1 16.4 24.2 25 25 10 2CE04502046* 19.5 2 23.5 33.1 35 35 8 2CE04503046* 28.8 2 34.6 47.1 50 50 6 2CE04501058 10.6 1 10.2 15.7 20 - 12 575-3-60 2CE04501558 2CE04502058 2 4 15.9 212 1 2 15.3 20.4 22.1 28.5 25 30 - - 10 10 2CE0450305830.4 _ 2 29.3 39.6 40 - 8 . 2CE04500525* 4.0 1 •.- 11.0 _ 41.3 50 50 6 2CE04500725* 5.6 1 15.6 41.3 50 50 6 2CE04501025 8.0 . 1 22.1 41.3 50 50 6 208-3-60 2CE04501525 7'3 11.9 , 2 33.1 50.6 60 60 6 2CE04502025 15.9 2 44.2 64.4 70 70 4 2CE04503025 22.2 2 61.7 86.3 90 90 2 2CE04500525* 5.3 1 12.7 41.3 50 50 6 2CE04500725* 7.5 1 18.0 41.3 50 50 6 230-3-60 2CE04501025 2CE04501525 7 3 10.6 15.9 1 2 25.5 38.2 41.3 56.9 50 60 50 60 6 4 076 2CE04502025 21.2 2 51.0 72.9 80 80 3 2CE04503025 29.6 2 71.2 98.1 100 100 1 2CE04500746* 6.8 1 8.2 21.0 25 25 10 2CE04501046* 10.1 1 12.1 . 21.0 25 25 10 460-3-60 2CE04501546* 3.7 13.6 1 16.4 25.1 30 30 10 2CE04502046* 19.5 2 23.5 33.9 35 35 3 2CE04503046* 28.8 2 34.6 47.9 50 50 6 2CE04501058 10.6 1 10.2 17.2 20 - 10 575-3-60 2CE04501558 20E04502058 2 8 15.9 21.2 1 2 15.3 20.4 22.7 29.0 25 30 - - 10 10 2CE04503058 30.4 2 29.3 " 40.1 45 - 6 1 Dual element, time delay type 2 Standard circuit breakers may be used in Canada and on applications over60 amps where the heaters are separately fused. 3 Based on 60°C copper conductors (up to 100 amps max or 75°C copper conductors (100 amps and over) ° These electric heaters DO NOT include a fuse box. If a fuse box is required to meet a local code ((eg., Chicago), the following fuse block accessories are available for field Installation. Central Environmental Systems Electric Heat Correction Factors Nominal Voltage Voltage KW Cap Multipier 1.00 0.92 0.92 201 208 240 230 480 460 600 575 _0,`2 Fuse Block 2FB04700425 208/240 Volts 2FB0g7Q051L. 46Q Yak 13 530.18-TG1 FIELD WIRING CONTACTOR i I t_GROUND LUG POWER WIRING FIELD -SUPPLED DISCONNECT 7 SINGLE O "J-- PHASE - 7- - 0- - - POWER SUPPLY L I CONTACTOR FIELD -SUPPLIED DISCONNECT r L -0-� p" -r_ THPHASEREE - O''0 --L POWER SUPPLY GROUNDL REFER TO THE ELECTRICAL DATA LUG TABLES TO SIZE THE DISCONNECT SWITCH, OVERCURRENT PROTEC- TION AND WIRING. L J 14 COOLING ONLY (24 VOLT THERMOSTAT) THERMOSTAT1 UN TTERMINAL TERMINALS STRIP TBI 24 VOLT TRANSFORMER CONTROL WIRING 124 VOLT THERMOSTAT 611408701024. IF THE UNIT HAS AN ECONOMIZER, REMOVE JUMPER J1 FROM TERMINALS 8 AND 10 ON THE RELAY BOARD TO PREVENT SIMULTANEOUS OPERATION OF THE COMPRESSOR AND THE ECONOMIZER. IF YOU WANT TO CONTROL THE ECONOMIZER ON A SECOND STAGE OF COOLING, USE THERMOSTAT6TH04702124. COOLING / HEATING (24 VOLT THERMOSTAT) THERMOSTAT1 TERMINALS UNIT TERMINAL STRIP TB1 _- 8 24 VOLT TRANSFORMER 124 VOLT THERMOSTAT 6TH07700124. IF THE UNIT HAS AN ECONOMIZER, REMOVE JUMPER J1 FROM TERMINALS 8 AND 10 ON THE RELAY BOARD TO PREVENT SIMULTANEOUS OPERATION OF THE COMPRESSOR AND THE ECONOMIZER. IF YOU WANT TO CONTROL THE ECONOMIZER ON A SECOND STAGE OF COOUNG OR HAVE AN ELECTRIC HEAT ACCESSORY WITH TWO STAGES OF HEAT, USE THERMOSTAT 6TH04702024. Central Environmental Systems UNIT DIMENSIONS (DHB AND DUC - 3, 4, 5 & 6 TON) FIELD•SUPPLIED DISCONNECT SWITCH LOCATION (Direct -Drive units) FILTER ACCESS r CONTROL BOC ACCESS BLOWER ACCESS 32.5/8 DHB UNITS 3 -ETON CONDENSER COMPRESSOR ACCESS ELECTRIC HEAT ACCESS 34" PVC FEMALE COND. DRAIN (See Detail "A") Sero BOTTOM SUPPLY & RETURN AIR OPENINGS (SEE NOTE) B - POWER WIRING ENTRY A - CONTROL WIRING ENTRY 83/8 2-1/2 UNIT BASE WITH RAILS Shown separately to Russets bottom duct openings and parer connection Iooatans. NOTE For curb -mounted units, refer to the duct hanger dimensions of the curb for the proper site of the guppy and return air duct connections. F1ELD-SUPPLIED DISCONNECT SWITCH LOCATION (Direct -Drive units) FILTER ACCESS - CONTROL BLOWER sox ACCESS ACCESS VENT AIR OUTLET H000 CONDENSER COMPRESSOR ACCESS COMBUSTION NR INLET HOOD 4 -318 _. 7 32-5/8 DUC UNITS 3-6 TON 34" PVC FEMALE COND. DRAIN (See Detail •A") 53/8 BOTTOM SUPPLY & RETURN AIR OPENINGS (SEE NOTE) B - POWER WIRING ENTRY GAS HEAT ACCESS 1 D OAS SUPPLY ENTRY 2.1/2 32•u4 UNIT BASE WITH RAILS Strom separaay to illustrate bottom duct evenings, power and gas piping connection locations. NOTE: Forcutb.mounted units. refer to the duos hanger dimensions of the curb to the proper size of the supply and return air duct connections. A - CONTROL WIRING ENTRY Central Environmental Systems 8.3'8 530.18-TG1 All dimensions are in inches. They are subject to change without notice. Certified dimensions will be provided upon request. • -M 1.,1 •.�1;•. 1:14 i41:7r.Ur*+77 .ef is i.1i^uif{7dyYdd•D'f 73ifP UTILITIES ENTRY DATA HOLE KNOCKOUT SIZE (DIA.) USED FOR A 7/g• • Control Wiring (Side or Bottom)** B 2" • Power Wiring (Side or Bottom) C 1-5/8" Gas Piping (Front) D 1-1/2" Gas Piping (Bottom) • Knockouts In the bottom of the unit can be located by the slice In the insulation. **Do not remove the 2' knockout ring. CLEARANCES Front DHB Units 24" DUC Units 32" Back 12" (Less Economizer) 36" (With Economizer) Left Side (Filter Access) 24" (Less Economizer) 36" (With Economizer) Right Side (Cond. Coil) 24,1 Below Un& 0" Above Unit2 72" (For Condenser Air Discharge) 1 Units may be Instated on combustible floors made from • wood or class A, B or C roof covering material. 2 Units must be installed oudoors. Overhanging structures or shrubs should not obstruct condenser air discharge Outlet. NOTES: DHB Models Units and ductwork are approved for zero clear- ance to combustible materials when equipped with electric healers. DUC Modelo: A 1' clearance must be provided between any combustible materiel and the supply air ductwork for a distance of 3 feet from the unit. The products of combustion must rat be allowed to accumulate within a confined space and recirculate. Locate unit so that the vent air outlet hood is at least: • Three (3) feet above any forced air inlet Located within 10 horizontal feet (excluding those integral to the unit). • Four (4) heat below, 4 horizontal feet from, or 1 toot above any door or gravity air Inlet Into the bulking. • Four (4) feet from electric meters, gas meters, reguaitors and relief equipment E> RETURN AIR SUPPLY AIR CONDENSER AIR OUTDOOR AIR L__ti; (Economizer) 15 530:18 -TG 1 U.NIT DIMENSIONS - CONT'D. (DHB and DUC - 3, 4, 5 & 6 TON) i„ii......:.., 4:...t....a: .4............. ....:„.... „In 111/2 1 ,..•..7....,...„::. r : -144-1;_,_, lir-------- 41)* ir is • '%1 -----"M r REAR VIEW 61/2"'� -----....i.4 ��. SIDE SUPPLY AND RETURN AIR \ DUCT OPENINGS' 774 DUCT COVERS - Units are shipped with all air duct openings covered. For side duct applications; 1.Remove and discard the supply and return air duct covers. 2.Connect ductwork to duct flanges on the rear of the unit. For bottom duct applications; 1. Remove the side supply air duct cover to gain access to the bottom supply air knockout panel. 2. Remove and discard the bottom knockout panel. 3. Replace the side duct cover. 14. With filter section access panel removed from the unit, remove and discard the bottom return air knockout panel. 5. Replace the filter access panel. 14s REAR VIEW DETAIL "A" UNIT WITH ECONOMIZER RAINHOOD L.H. ENO VIEW DETAIL "B" UNIT WITH FIXED OUTDOOR AIR / BAROMETRIC RELIEF RAINHOOD 81/4 4474 B BACK 821/4 DIM. A 3-5 TON 19-3/4" 6 TON 22" 44" APPROXIMATE CENTER OF GRAVITY 16 FRONT CENTER OF GRAVITY A 40-3/4' CONDENSER COIL END OF UMT Central Environmental Systems ROOF CURB DIMENSIONS - (DHB and DUC - 3, 4, 5 & 6 TON) BACK OF UNIT RETURN' AIR DUCT SUPPORT RAILS SUPPLY' AIR 2" COMPRESSOR AND CONDENSER END OF UNIT 37.1/4" DUCT SIZES; Supply Air . 19-1/4" X 19-1/4" Retum Air a 19.1/4" X 19-1/4" ROOF CURB BENEFITS 73" FRONT OF UNIT 530.18-TG1 'Suppy and Return Air (including duct support rails) shown are typical for Bottom duct applications. For location of 1312gzggial duct applicattons (on back of unit), refer to Unit Dimension details. FRONT VIEW (3 -JOIST SUPPORT) 73' SUPPORT RAILS The 41h' space :•'• between the ducts albwsfor ".......:.•m•h, an ex - FRONT VIEW (2 -JOIST SUPPORT) NOTE Both supply air and return air dud openings are square and are the same sirs, pro- viding easy duct installation. Ducts can be installed onto the curb from the root. All eBdrical wiring connedions can be made inside the curb. UNIT AND CURB APPLICATION 48' n ALTERN The 43W overall duct dimension alows ductwork penetration between root joists that are spaced on 48' centers. 3/4" X 1.1/4" WIDE GASKETING FOR CURB FRAME AND ALL DUCT SUPPORT SURFACES UNIT BASE- L WOOD NAILER— UNIT BASE RAILS 14„ 8" MIN. ABOVE FINISHED ROOF — ' COUNTERFLASHING CURB FRAME— CANT STRIP INSULATION AND ROOFING MATERIAL INSULATION ROOF DECK AND SUPPORT STRUCTURE Central Environmental Systems 17 530.18-TG1 TYPICAL APPLICATIONS 1) ROOF JACK INSTALLATION ROOF CURB / INSTALLATION f 1 1 1 1 1 ! 1 I 11 1 1 1 1 1 1 1 1 I [ 1 1 1 r 1 1 I 1-k I 1 I {,_..—.+ L.. -.J SLAB ON GROUND INSTALLATION f) 4)o TYPICAL ROOF -TOP INSTALLATION (MODEL DUC SHOWN) FIELD -SUPPLIED DISCONNECT SWITCH • �y .�-, at. 41.: f•• • -S-,, UUa....els lJW. 11111111111111111mm .irrttirlrl11m! toi 1 T CONDENSA TRAP 1 TO CONTROL WIRING POWER TO INDOOR SUPPLY THERMOSTAT 18 RETURN AIR DUCT DRIP LEG affix' • .fit•^;-no�, OO rf+,p��r�4sq���gr�rV� SUPPLY AIR DUCT ROOF CURB 1 `p • MANUAL GAS SHUT-OFF VALVE TO GAS SUPPLY LINE Central Environmental Systems 6/28/2019 / \. f `\ \. J City of Tukwila Department of Community Development FRED BARBER 6046 LAKE SHORE DR S SEATTLE, WA 98118 RE: Permit No. M18-0162 GENERAL INSULATION 410 ANDOVER PARK E Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 8/24/2019. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 8/24/2019, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincgrely, .7%s Kandace Nichols Permit Technician File No: M18-0162 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 r'ERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M18-0162 DATE: 12/4/18 PROJECT NAME: GENERAL INSULATION SITE ADDRESS: 410 ANDOVER PARK E X Original Plan Submittal Response to Correction Letter # Revision # Revision # before Permit Issued after Permit Issued DEPARTMENTS: AT- ci Building Division 111 Public Works n AK ta:-10-te 4 Fire Prevention Structural Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 12/06/18 Structural Review Required REVIEWER'S INITIALS: DATE: n APPROVALS OR CORRECTIONS: Approved Corrections Required ❑ Approved with Conditions Denied (corrections entered in Reviews) (ie: Zoning Issues) DUE DATE: 1/03/19 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping ❑ PW 0 Staff Initials: 12/18/2013 CSIHVAC INC Washington State Department of Labor & Industries 7 +\ Page 1 of 2 Hoene Espanol Contact Search L&I A -Z index Help 'iy t,UU Safety & Health Claims & Insurance Workplace Rights Trades & Licensing CSIHVAC INC Owner or tradesperson Principals SVENDSEN, KEVIN CHRISTIAN, MEMBER NORMAN, DAVID ALAN, MEMBER Doing business as CSIHVAC INC WA UBI No. 603 191 807 3534 N SHIRLEY TACOMA, WA 98407 253-224-8301 PIERCE County Business type Corporation Governing persons KEVIN CHRISTIAN SVENDSEN DAVID A NORMAN; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. CSIHVI*880KD Effective — expiration 05/04/2012— 05/04/2020 Bond American Contractors Indem CO Bond account no. 100192835 Active. Meets current requirements. $12,000.00 Received by L&I Effective date 05/04/2012 04/11/2012 Expiration date Until Canceled Insurance Scottsdale Ins Co $1,000,000.00 Policy no. CPS -3053326 Received by L&I Effective date 03/26/2018 03/26/2018 Expiration date 03/26/2019 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings ....... ...... Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=603191807&LIC=CSIHVI* 880KD&SAW= 12/17/2018 CSIHVAC INC No lawsuits against the bond or savings acc,, ZZs during the previous 6 year period. L&I Tax debts ..... ..................... No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&l Account ID 241,670-00 Doing business as CSIHVAC INC Estimated workers reported Quarter 3 of Year 2018 "0" Workers L&I account contact T2 / LINDA ALGUIRE (360)902-4678 - Email: POTH235@Ini.wa.gov Account is current. Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health No inspections during the previous 6 year period. Page 2 of 2 Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=603191807&LIC=CSIHVI*880KD&SAW= 12/17/2018