HomeMy WebLinkAboutPermit M18-0109 - QUAIL PARK AT RIVERTON CREEK - HEAT PUMP SYSTEMS, ROOFTOP UNITS, FANS, AIR UNITS, DUCTS, ETCQUAIL PARK AT RIVERTON CREEK 13112 MILITARY RD S APN: 1623049179 EXPIRED 03/08/2021 M18-0109 CITY OF TUKWIL Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. N'? t 0^01 o 9 Project No. Date Application Accepted: /'- Date Application Expires: (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address: 13112 Military Road S. King Co Assessor's Tax No.: 162304-9179 Suite Number: Tenant Name: Quail Park of Tukwila LLC PROPERTY OWNER Name: Scott Chritton Name: Quail Park of Tukwila LLC Address: 1711 Port Drive Address: 146 N. Canal Street, Suite 220 City: Burlington State: WA City: Seattle State: WA Zip: 98103 CONTACT PERSON — person receiving all project communication Name: Scott Chritton Address: 1711 Port Drive Address: 1711 Port Drive Phone: (360) 757-6909 Fax: (360) 757-6919 City: Burlington State: WA zip: 98233 Phone: (360) 757-6909 Fax: (360) 757-6919 Email: scott@rhmech.com Floor: New Tenant: m Yes ❑..No MECHANICAL CONTRACTOR INFORMATION Company Name: R&H Mechanical, Inc. Address: 1711 Port Drive City:Burlington State: WA Zip: 98233 Phone: (360) 757-6909 Fax: (360) 757-6919 Contr Reg No.: RHMECHI*951LC Exp Date: 07/19/2019 Tukwila Business License No.: Valuation of project (contractor's bid price): $ 1,391,161 Describe the scope of work in detail: Install VRF heat pump systems, packaged rooftop units, exhaust fans, supply fans, kitchen make up air units, welded grease ducts, pool dehumidification system, packaged terminal heat pumps, vertical terminal heat pumps, ductless heat pumps, ductless air conditioners, refrigeration piping, controls, ductwork, duct insulation,vibration isolation, labeling. Use: Residential: New ❑ Replacement ❑ Commercial: New Replacement ❑ Fuel Type: Electric Gas m Other: H: Applications'Ponos-Applications On Line 2016 Applications` 1echanical Permit Application Revised I-4-16.docx Revised: January 2016 bh Page 1 of2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu 199 Furnace >100k btu 372 Floor furnace 290 Suspended/wall/floor mounted heater 57 dB(A) Appliance vent 244 Repair or addition to heat/refrig/cooling system 47 dB(A) Air handling unit 65 dB(A) <10,000 cfm 60 dB(A) Unit Type Qty Air handling unit >10,000 cfm 199 Evaporator cooler 372 Ventilation fan connected to single duct 290 Ventilation system 57 dB(A) Hood and duct 3 Incinerator — domestic 47 dB(A) Incinerator — comm/industrial 65 dB(A) Unit Type Qty Fire damper 63 Diffuser 372 Thermostat 199 Wood/gas stove 57 dB(A) Emergency generator Commercial Other mechanical equipment 47 dB(A) 60 dB(A) 65 dB(A) Boiler/Compressor Qty 0-3 hp/100,000 btu 6 3-15 hp/500,000 btu 1 15-30 hp/1,000,000 btu 3 30-50 hp/1,750,000 btu 57 dB(A) 50+ hp/1,750,000 btu Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-IOPM, Monday through Friday and 8AM-10PM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: Warning devices; • Construction and property maintenance during the daytime hours (lam -1 Opm); • Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction -- in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OW Signature: R AU ORIZED AGENT: Print Name: Mailing Address: // p /% efuaStr'et. Day Telephone: 1-1 Applications'Forms-Applications On Line 2016 ApplicationsiMechanical Permit Application Revised 1-4-16.docx Revised. January 2016 bh Date: .za- / 1 � 1i// /03 C try State Zip Page 2 of 2 r sh{ Register Receip City of Tukwila f \ DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $10,175.26 EL18-0745 Address: 13112 MILITARY RD S Apn: 1623049179 $4,037.38 ELECTRICAL $4,037.38 PLAN CHECK FEE R000.345.832.00.00 0.00 $4,037.38 M18-0109 Address: 13112 MILITARY RD S Apn: 1623049179 $2,908.10 MECHANICAL $2,908.10 PERMIT FEE R000.322.100.00.00 0.00 $223.83 PLAN CHECK FEE R000.322.102.00.00 0.00 $2,684.27 PG18-0110 Address: 13112 MILITARY RD S Apn: 1623049179 $3,229.78 GAS $71.27 PLAN CHECK FEE R000.322.103.00.00 0.00 $71.27 PLUMBING $3,158.51 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R15275 R000.322.103.00.00 0.00 $3,158.51 , $10,175.26 Date Paid: Tuesday, August 28, 2018 Paid By: QUAIL PARK OF TUKWILA LLC Pay Method: CHECK 1112 Printed: Tuesday, August 28, 2018 12:16 PM 1 of 1 SYSTEMS 1/2/2020 City of Tukwila Department of Community Development SCOTT CHRITTON 1711 PORT DR BURLINGTON, WA 98233 RE: Permit Application No. M18-0109 QUAIL PARK AT RIVERTON CREEK 13112 MILITARY RD S Dear SCOTT CHRITTON, Allan Ekberg, Mayor Jack Pace, Director In reviewing our current application files, it appears that your permit applied for on 8/28/2018, has not been issued by the City of Tukwila Permit Center. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or National Electrical Code every permit application not issued within 180 days from the date of application shall expire and become null and void. Currently your application has a status of APPROVED and is due to expire on 2/28/2020. If you still plan to pursue your project, you are hereby advised to do one of the following: 1) If the plan review is complete for the project and your application is approved, you may pick up the application before the date of expiration. At the time of permit issuance the expiration date will automatically be extended 180 days. -or- 2) If the plan review is not completed submit a written request for application extension (7) seven days in advance of the expiration date. Address your extension request to the Building Official and state your reason(s) for the need to extend your application. The Building Code does allow the Building Official to approve one extension of up to 90 days. If it is determined that your extension request is granted, you will be notified by mail. In the event that we do not receive your written request for extension or request is denied, your permit application will expire and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: M18-0109 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 2012 Washington State Energy Code Compliance Forms for Commercial, Group1, REMEWEDa, Economizer Exceptions Alterations/Simple Syster 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 o m "4#1;a,'H-ECONO .-r 3 stor d 7 . - ? ' i vised A g 2015 Project Info Project Address: QUAIL PARK AT RIVERTON CREEK D to 12/17 2018 13112 MILITARY ROADS Fo Building 4AtRU4 4 2019 City of Tukwila BUILDING DIVISION TUKWILA, WA 98168 Applicant Name: MATT BROOKS, P.E. Applicant Address: 21705 HIGHWAY 99, LYNNWOOD, WA Applicant Phone: 425-741-1200 Economizer Exception Summary Refer to Section 0403.3.1 and C403.4.1 for descriptions of economizer provisions and exceptions. For alterations refer to Section C101.4.3.2 and Table C101.4.3.1. Economizer Exceptions - Alterations Table Alterations or replacement C101.4.3.1 may comply with an applicable as defined in Table C101.4.3.1. or Replacement of existing mechanical equipment economizer compliance Option System ID Equipment Type Compliance Path t--1 .f---, 1 1 1 I 1-'� , __,._. Economizer Exceptions - Simple Systems SS Exp1 Qualifying small equipment. Per unit limit is 33,000 Btu/h. Per building capacity limit for this exception is 72,000 Btu/h or 5% of required building air economizer capacity, whichever is greater. Efficiency shall be 15% better than required minimum. Not eligible: non -unitary equipment, unitary equipment installed outdoors or in mech room adjacent to outdoors, equipment installed during new construction, shell -and -core construction, or initial tenant improvement. Total Claimed Exempt Total building air economizer capacity (if claimed Alternate SS Expl System ID Cooling g Capacity (Btu/h) FCU -1 29,515 FCU -2 29,515 Capacity: > 72,000 Btu/h): Capacity Limit: 59030 SS Exp2 Systems with dehumidification that affect other systems such that air economizer would increase energy consumption. System ID SS Exp3 Group R cooling equipment. Per unit limit is 20,000 Btu/h for simple cooling equipment installed outdoors or in a mech room adjacent to the outdoors. For simple cooling equipment installed in other locations the unit limit is 54,000 Btu/h. Efficiency shall be 15% better than required minimum. System ID Equipment Location Cooling Capacity (Btu/h) VTAC-1 Mech Room 12000 VTAC-2 Mech Room 17500 PTHP-1 Mech Room 9300 SS Exp4 Pending rule per WAC 51-11C-40331. Equipment cooling efficiency meets or exceeds 64% in Climate Zone 4C and 59% in Climate Zone 5B per revised Table C403.3.1(2). System ID VRF-1 216000 VRF-2 336000 VRF-3 336000 VRF-4 122000 SS Exp5 Simple cooling equipment for dedicated server rooms, electronic equipment rooms (including elevator machine rooms), or telecom switch rooms. These systems are eligible under CS Exp5 . The total allowance for equipment utilizing this exception includes the sum of both simple and complex systems. Document under CS Exp5 CORRicTION LTR# Mt8 Oioq RECEIVED CITY OF TUKWILA JAN 1 5 2019 PERMIT CENTER 4 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Economizer Exceptions, Complex Systems MECH-ECONO 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Aug 2015 Economizer Exception Summary Refer to Section C403.3.1 and C403.4.1 for descriptions of economizer provisions and exceptions. For alterations refer to Section C101.4.3.2 and Table C101.4.3.1. Project Address: QUAIL PARK AT RIVERTON CREEK Date 12/17/2018 Economizer Exceptions - Complex Systems CS Expl Water-cooled chilled beam and chilled ceiling systems with water economizer. Capacity limit for all water economizer systems is 500 tons per building. Total building water economizer capacity (tons stem ID System Water Economizer Capacity (tons) - all systems): CS Exp2 Water -source heat pumps with heat recovery. Heat pump efficiency shall be 15% better than required minimum. Provide at minimum 60% air economizer. Energy recovery to preheat OSA shall have at least 50% effectiveness. Additional system requirements apply. System ID CS Exp3 Chilled water terminal units. Part load efficiency of chilled water generation equipment shall be 25% better than required minimum. Per building limit of all systems without air economizer is 480,000 Btu/h or 20% of required building air economizer capacity, whichever is greater. Total Claimed Exempt Total building air economizer capacity (if claimed > Alternate CS Exp3 System ID Cooling Capacity (Btu/h) Capacity: 480,000 Btu/h): Capacity Limit: CS Exp4 Group R cooling equipment. Per unit limit is 20,000 Btu/h for equipment installed outdoors or in a mech room adjacent to the outdoors. For cooling equipment installed in other locations the unit limit is 54,000 Btu/h. Efficiency shall be 15% better than required minimum. System ID Equipment Location Cooling Capacity (Btu/h) CS Exp5 Equipment for dedicated server, electronic equipment or telecom switch rooms. Per building limit of all systems without air economizer is 240,000 Btu/h or 10% of required building air economizer capacity, whichever is greater. Part load control required over 85,000 Btu/h. Additional requirements apply. Option a - Efficiency shall be 15% better than required minimum. Option b - Efficiency shall be 5% better than required minimum. Waterside economizer required. Option c - All cooling equipment is subject to ASHARE Standard 127. Waterside economizer required. Option d - Chiller efficiency shall be 25% better than C403.2.3(7) full load and part load minimum. No economizer required. Option e - Chiller efficiency shall be 10% (air cooled) /15% (water cooled) better than C403.2.3(7) minimum. Dedicated waterside economizer required. Total Total building air economizer capacity EXCEEDS CS EXP5 CAPACITY LIMIT Alternate System ID Compliance Option Cooling Capacity (Btu/h) IAC/OAC-1 Option a 13,785 IAC-2,3,4/OAC- 2 p IAC-5,6,7/OAC- 3 Claimed Exempt Capacity: (if claimed > 240 kBtu/h): CS Exp5 Capacity Limit: 90585 CS Exp6 Variable refrigerant flow (VRF) systems with energy recovery. Limited to buildings 60,000 sf or less. Outdoor unit min. capacity is 65,000 Btu/h. Energy recovery to preheat OSA shall have at least 50% effectiveness. Zones served shall be at least 20% interior and 20% perimeter. Additional requirements apply. System ID Outdoor Unit Cooling Capacity (Btu/h) 2012 Washington State Energy Code Compliance Forms for Commercial, Group Mechanical Permit Plans Checklist - Page 1 of 4 A„ and -R3 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all 1 IV WI ME ;H -CHK evised Au a 2015 Project Address QUAIL PARK AT RIVERTON CREEK APPROVED )2/17/2018 The following information is necessary to check a permit application for compliance with the mechanicial systems and equipment' Washington State Energy Code, Commercial Provisions requirements of the Applicable (yes,no,na) Code Section Code Provision Information Required - Must be in permit docu MAR 0 4 nents Qban in Documents Bui ding Department Notes GENERAL PROVISIONS Equipment Sizing & Performance City of Tukwila YES 0403.2.1 Load calculations BUILDING DWISiON Load calculations performed per ASHRAE Std 183 or equivalent p -r t,napter i YES C403.2.2 Equipment and system sizing Output capacities of heating and cooling equipment and systems do not exceed the next larger available equipment size above the calculated loads; note exceptions taken ATTACHE D YES 0403.2.5 Minimum ventilation Ventilation (natural or mechanical) provided per IMC; indicate mechanical ventilation is capable of being reduced to minimum requirement per IMC �- ATTACHE r. —� ' YES C403.2.3 & 0403.2.3.2 & 0403.2.12.1 Equipment minimum efficiency Provide equipment schedules or complete MECH-SUM tables with type, capacity effciee test standard (or other efficiency source) for all mechanical equipment f y, —o• O. 11 . , 1 I ___1 { ` _� 1 YES 0403.2.13 Electric motor efficiency Provide equipment schedule with hp, rpm, and efficiency for all motors; note exceptions taken Lase MO. NA 0403.2.10.1 Fan power limitation For all applicable systems > 5hp, provide system total nameplate hp in MECH-FANSYS-SUM form NA 0403.2.10.1 Fan power limitation For all applicable fan systems > 5hp, verify fan system motor hp or bhp complies with fan power limits per Table 0403.2.10.1)1), provide MECH-FANSYS form for each system YES 0403.2.10.2 Motor nameplate hp Indicate fan motors specified are the smallest available motor hp size greater than fan bhp, note exceptions taken M0.01 YES 0403.2.10.3 & 0403.2.13 Fractional hp fan motors Indicate fan motors 1/12 to 1 hp are ECM type or meet minimum efficiency req. M0.01 NA 0403.2.3 Maximum air cooled chiller capa Indicate air-cooled chiller capacity does not exceed air-cooled chiller limit CO P tr "� NA C403.2.3.1 Non -city Non - Non-standard water-cooled chillers Full -load and NPLV values for water-cooled centrifugal chiller adjusted for non-standard operational conditions rrT 1 1 NA 04032.12.1.2 Centrifugal fan cooling towers Large capacity cooling towers with centrifugal fan(s) meet efficiency requirements for axial fan open circuit cooling towers NA 0403.2.3 Forced air furnace and unit heaters Indicate intermittent ignition or IID, flue/draft damper & jacket loss yes C403.2.3.3 Packaged electric heating/cooling equipment Verify all packaged electric equipment that provides > 20,000 Btu/h cooling capacity and heating is a heat pump, note in equipment schedule M0.01 NA 0403.2.3.4 Humidification Indicate method of humidification (note requirements for systems with economizer) HVAC System Controls & Criteria YES 0403.2.4.1 Thermostatic controls Indicate locations of thermostatic control zones on plans,including perimeter systems M0.01 YES 0403.2.4.1.1 Heat pump supplementary heat Indicate staged heating (compression/supplemental) and outdoor lock -out temperature is set to 40°F or less M0.01 YES 0403.2.4.2 Setpoint overlap (deadband) Indicate 5°F deadband minimum for systems controlling both heating & cooling M0.01 YES 0403.2.4.3 Automatic setback and shutdown Indicate zone t -stat controls with required automatic setback & manual override M0.01 YES 0403.2.4.3.3 Automatic (optimum) start (p ) Indicate system controls that adjust y equip start time to match load conditions M0.01 YES 0402.4.5.2 & 0403.2.4.4 OSA, exhaust, and relief air dampers P Indicate location of outdoor air supply intake, and exhaust and relief outlet dampers; verify Class 1 leakage ratingand control type(motorized or gravity);note exceptions taken 9 YP P M0.01 YES 0402.4.5.2 Return air dampers Indicate location of return air dampers that are integral to economizer operation; verify motorized control and Class 1 leakage rating; note exception taken M0.01 NA 0402.4.5.1 Stairway and shaft vents Indicate location of stairway and shaft vents, verify Class 1 leakage rated motorized dampers and method of activation REC ;.IVE D NA 0403.2.11 Heating outside a building Indicate radiant heat system and occupancy controls CI_ iVOF p TU K W I LA NA 0403.2.4.5 Snow melt systems Indicate shut-off controls based on outdoor conditions JAN 1 5 2019 NA C403.2.4.6 Combustion heating equipment Indicate modulating or staged control NA 0403.2.4.7 Group R1 hoteVmotel systems Indicate method for guest room temperature automatic setback (heating) & set-up (cooling) E confirm adjustment of at least 5°F minimum. H 114 II C E N T E R YES 0403.2.4.8 / g Group R2/R3 dwelling and sleeping unit systems Indicate 5-2 programmable thermostats in primary spaces with minimum of two setback M0.01 periods and 10°F deadband; note exceptions taken NA 0403.2.5.1 Demand controlled ventilation Indicate high -occupancy spaces and systems requiring DCV NA 0403.2.5.2 Occupancy sensors Indicate spaces requiring occupancy -based system control and method; or alternate means provided to automatically reduce OSA when partially occupied tkit I - I nq 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Mechanical Permit Plans Checklist - Page 2 of 4 MECH-CHK 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Aug 2015 Project Address QUAIL PARK AT RIVERTON CREEK Date 12/17/2018 The following information is necessary to check a permit application for compliance with the mechanicial systems and equipment requirements of the Washington State Energy Code, Commercial Provisions. Applicable (yes,no,na) Code Section Code Provision Information Required - Must be in permit documents Location in Documents Building Department Notes GENERAL PROVISIONS, CONTINUED HVAC System Controls & Criteria, Continued na C403.2.5.3 Enclosed loading dock/parking garage ventilation Indicate enclosed loadingdock and enclosed parking p g garage ventilation system activation and control method yes 0403.2.5.4.1 Kitchen exhaust hoods Indicate kitchen hoods requiring make-up air; indicate make-up air source and conditioning method M0.01 no C403.2.5.4.2 Laboratory exhaust systems Indicate lab exhaust systems requiring heat recovery, method & efficiency; or alternative method taken (VAV, semi -conditioned makeup, or GERM calculation) yes 0403.2.6.1 Energy recovery (ER) - ventilation systems Indicate ventilation systems requiring ER, method & efficiency; note exceptions M0.01 na 0403.2.6.2 Energy recovery (ER) condensate systems Indicate on-site steam heating systems requiring energy recovery na C403.2.6.3 Energy recovery (ER) cooler/freezer condensers Indicate remote refrig. condensers requiring ER and use of captured energy na 0403.4.6 Energy recovery (ER) - condenser systems Indicate condenser systems requiring ER to pre -heat service water; indicate ER effectiveness; note exceptions taken na 0403.2.12 Variable flow control - fans/pumps Indicate fan and pump motors z 7.5 hp and the method of variable flow control (VSD or equivalent controls) na 0403.2.12.1 Variable flow control - heat rejection equipment Indicate heat rejection equipment and cooling tower fans requiring variable flow control and method na C403.2.12.2 Large volume fan systems Indicate single zone fan systems requiring airflow reduction capability in response to reduced cooling or heating demand in a zone, or adjacent zones without separating walls, with > 10,000 CFM supply air; note exceptions taken yes 0403.2.12.2 Single zone AC systems Indicate method of cooling demand -based fan control for air conditioning systems > 110,000 Btu/h serving single zones M0.01 na 0403.2.4.10 DDC system capabilities Identify all DDC system input/output control points and indicate capability for trending and demand response setpoint adjustment Ducting Systems yes 0403.2.7.1 &Duct 0403.2.7.3 construction Indicate all ductwork constructed and sealed per IMC, C402.4 leakage requirements and IBC vapor retarder requirements M0.00 yes 403.2.7.3.1: Duct pressure classifications Identify location of low, medium and high pressure ductwork on plans M0.00 na 0403.2.7.3.3 High pressure duct leakage test Indicate high pressure duct leakage testing requirements on plans; provide test results to jurisdiction when completed M0.01 yes 0403.2.7.1 / 2 Duct insulation Indicate R -value of insulation on ductwork M0.01 Piping Systems yes 0403.2.8 Piping insulation Indicate R -value of insulation on piping M0.01 yes 0403.2.8.1 Piping insulation exposed to weather Indicate method of protection from damage/degredation M0.01 SIMPLE SYSTEMS Qualifying Systems yes 0403.3 Qualifying single zone systems Verify unitary or packaged equipment does not exceed capacity limits, does not have active humidification or simultaneous heating/cooling M0.01 na C403.3 Qualifying 2 -pipe heating systems . Verity 2 -pipe heating -only system does not exceed capacity limits na 0403.3.2 Hydronic system controls Refer to Complex Systems Section 0403.4.3 Simple System Economizers yes 0403.3.1 Air economizer required Indicate cooling systems requiring economizer controls; note in equipment schedule M0.o1 yes C403.3.1 Air economizer exceptions Indicate eligible exception(s) taken and provisions to comply with exception(s) M0.01 yes C403.3.1.1.1 Air economizer capacity Indicate modulating OSA control capability up to 100% OSA; note exceptions taken M0.01 yes 0403.3.1.1.2 Integrated air economizer operation Indicate capability for partial air economizer operation for systems with capacity > 65,000 Btu/h M0.01 yes 0403.3.1.1.3 Air economizer high limit controls Indicate high limit shut-off control method per Table 0403.3.1.1.3(2) M0.01 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Mechanical Permit Plans Checklist - Page 3 of 4 MECH-CHK 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Aug 2015 Project Address QUAIL PARK AT RIVERTON CREEK Date 12/17/2018 The following information is necessary to check a permit application for compliance with the mechanicial systems and equipment requirements of the Washington State Energy Code, Commercial Provisions. Applicable (yes,no,na) Code Section Code Provision Information Required - Must be in permit documents Location in Documents Building Department Notes COMPLEX SYSTEMS Complex System Economizers yes C403.4.1 Air economizer required Indicate cooling systems requiring economizer controls; note in equipment schedule M0.01 yes C403.4.1 Air economizer exceptions Indicate eligible exception(s) taken and provisions to comply with exception(s) M0.01 na C403.4.1.1 Water economizer capacity For eligible systems where water economizer may be provided in lieu of air economizer, indicate system is capable of 100% cooling capacity at 50°F db/45°F wb OSA na C403.4.1.2 Water economizer maximum pressure drop Indicate precooling coils and heat exchangers in water economizer system do not exceed pressure drop limit yes C403.4.1.3 Integrated economizer operation Indicate capability for partial economizer operation for air or water economizer systems M0.01 na C403.4.1.4 Economizer heating system impact Verify control method of HVAC systems with economizers does not increase building heating energy usage during normal operation Specific System Requirements na C403.4.2 & C403.2.12 VAV fan control Indicate fans requiring variable flow control and method na 0403.4.2.1 VAV fan static pressure sensors Indicate sensor locations on plans; include at least one sensor per major duct branch na C403.4.2.2 VAV fan static pressure setpoint Indicate fan system static pressure setpoint based on zone requiring most pressure na C403.4.5 VAV systems serving multiple zones Indicate supply air systems serving multiple zones, method of primary air control, and zones served; Indicate VAV or note exceptions taken na 0403.4.5 VAV systems serving multiple zones For each air system terminal, indicate the maximum air flow rate of primary supply air during zone peak cooling and the maximum air flow rates during zone peak heating. na C403.4.5.4 VAV system supply air reset Indicate controls that automatically reset supply air temp in response to loads na C403.4 Large capacity cooling systems Indicate method of multi -stage or variable control for building cooling system capacity > 300 tons na C403.4.7 Hot gas bypass limitation Indicate cooling equipment unloading or capacity modulation method na C403.4.3 Large capacity boiler systems Indicate multi -stage or modulating burner for single boilers > 500,000 Btu/h na C403.4.3 Boiler sequencing Indicate automatic controls that sequence operation of multiple boilers na C403.4.3.5 Chiller / boiler plant pump isolation Indicate capability to automatically reduce overall plant flow and shut-off flow through chillers & boilers when not in use na C403.4.3.6 & C403.2.12 Variable flow control pumps Indicate pumps requiring variable flow control & method na C403.2.12.1 & C403.4.4 Variable flow control cooling towers Indicate cooling tower fans requiring variable flow control and method na C403.4.3.4 Hydronic system part load controls Indicate heating & chilled water systems have the capability to automatically reset supply water temp AND reduce flow by t 50% for systems > 300,000 Btu/h na 0403.4.3.2 Two -pipe changeover systems Indicate deadband, heating/cooling mode scheduling and changeover temperature range na C403.4.3.3.1 Water loop heat pump - deadband Indicate capability of central equipment to provide min. 20°F water supply temp deadband between heat rejection and heat addition modes na C403.4.3.3.2.1 Water loop heat pump - heat rejection, Zone 4 Indicate method used to limit system heat loss when heat rejections is not needed na C403.4.3.3.2.2 Water loop heat pump - heat rejection, Zone 5 Provide heat exchanger that separates cooling tower and heat pump loop na C403.4.3.3.3 Water loop heat pump - isolation Indicate 2 -way isolation valve on each heat pump and variable flow control for systems with total pump power > 10 hp na C403.5 Walk-in cooler / freezer - anti -sweat heaters Indicate w/sf & control method for walk-in cooler/freezer door anti -sweat heaters na C403.5 / 6 Cooler / freezer - evaporator and condenser fans Indicate motor type for evaporator and condenser fans < 1 hp 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Mechanical Permit Plans Checklist - Page 4 of 4 2012 Washington State Energy Code Compliance Forms for Commercial Buildings includi nd all R1 MECH-CHK Revised A Project Address OUAIL PARK AT RIVERTON CREEK Date 12/17/2018 The following information is necessary to check a permit application for compliance with the mechanicial systems and equipment requirements of the Washington State Energy Code, Commercial Provisions. Applicable (yes,no,na) Code Section Code Provision Information Required - Must be in permit documents Location in Documents Building Department Notes SERVICE WATER HEATING Service Water Systems na C404.2 Water -heating equip min. efficiency Provide equipment schedule with type, capacity, efficiency, test standard or other efficiency source na C404.3 Temperature controls Indicate temperature controls have required setpoint capability na C404.4 Heat traps Indicate piping connected to equipment have heat traps on supply & discharge na C404.5 Insulation under water heater Indicate R-10 insulation under electric water heater tanks na C404.6 Service water piping insulation Indicate R -value of insulation on piping; note exceptions taken na C404.7 / g Circulation systems and heat trace shut-off Indicate shut-off capability based on occupancy and periods of limited demand na C404.9 Group R-2 service hot water meters Indicate method of usage metering for dwelling units served by a central service hot water system Pools & In -Ground Permanently Installed Spas na C404.10.1 Pool heating equip min. efficiency Provide equipment schedule with type, capacity, efficiency, test standard or other efficiency source na C404.10.1 / 2 Pool heater on /off controls Indicate automatic on/off control based on scheduling & accessible on/off switch on heater that operates independent of thermostat setting; note exceptions taken na C404.10.3 Pool covers Indicate vapor retardant cover and insulation rating as required na C404.10.3 Pool assembly insulation Indicate rating of insulation on sides and bottom of pools heated to > 90°F na C404.10.4 Heat recovery Indicate method, exhaust air temperature reduction and recovered energy use; note exceptions taken COMMISSIONING Specific System Requirements yes 0408.2 Mechanical systems commissioning Indicate all mechanical systems to be commissioned; for those that will not be commissioned, note exception taken M0.02 yes C408.4 Service water heating systems commissioning Indicate all service water heating systems to be commissioned; for those that will not be commissioned, note exception taken M0.02 yes C408.1.1 Commissioning plan Provide commissioning plan for all systems requiring commissioning; include in plan all required items per this section M0.02 yes C408.2.2.1 & C408.2.2.2 Air system and hydronic system balancing Include in commissioning plan that air and hydronic systems shall be balanced in a manner to first minimize throttling losses, then adjust to meet design flow conditions M0.02 yes C408.2.2.1 Air system balancing devices Indicate devices that provide the capability to balance all supply air outlets, zone terminals and equipment requiring system balancing M0.02 na C408.2.2.2 Hydronic system balancing devices Indicate devices that provide the capability to isolate, balance and measure flow for all hydronic equipment requiring system balancing yes C408.2.3 Mechanical systems functional performance testing Provide description of functional performance testing procedures for all applicable systems including: equipment, controls, economizers M0.02 na C408.4.1 Service water heating functional performance testing ti Provide l i of f descri on unctonaperformance testing p procedures for all applicable systems including: equipment, controls, pools and spas yes C408.1.4 Systems operation training Indicate required systems operation training measures to be provided M0.02 yes C408.1.2 & C403.1.3 Documentation Indicate required documentation including: record documents, manuals, balancing reports, commissioning preliminary and final reports M0.02 yes C408.1.2.1 Acceptance report Indicate that Commissioning Compliance Checklist (Figure C408.1.2.1) is required upon completion of preliminary commissioning report M0.02 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Mechanical Summary 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all - ,t;H-SUM i 015 Project Info Project Address: QUAIL PARK AT RIVERTON CREEK yODECOIYff'[L�/i ,18 13112 MILITARY ROADS "l03 1 . se 0 4 2019 of Tukwila TUKWILA, WA 98168 Applicant Name: MATT BROOKS, P.E. MAR Applicant Address: 21705 HIGHWAY 99, LYNNWOOD, WA Applicant Phone: 425-741-1200 City Project Briefly the Description describe mechanical systems in text box provided • Total Bldg Performance Total Bldg Performance compliance includes all mandatory provisions perPJAN C401.2 Option 2. MECH-SUM, MECH-CHK, and C407 Energy Analysis Summary forms required. 0 New Building Building❑Addition Tenant❑Improvement ❑ fi/ C O@ M C T! A �� ye�11ttOIIN�a3rlOIVs t c t i V t U CITY OF TUKWILA _ i i V r + 1 2019 ) �^ _ PERMIT CENTER Mechanical Systems Summary Equip ID Type of System (Note 1) Space(s) Served Compliance Path Heating and Cooling Fan Flow Controls Air Economizer (Note 2) Ventilation (Note 3) Energy Recovery FCU -0P2- A VRF AIR HANDLER FITNESS Complex multi zone system Heating and cooling Constant volume (CV) CS Exp5b Minimum per IMC Provided but not required FCU -002- A VRF AIR HANDLER EAL DINING Complex multi. zone system Heating and cooling Constant volume (CV) CS Exp5b Minimum per IMC Provided but not required FCU -003- A VRF AIR HANDLER FITNESS Complex multi. zone system Heating and cooling Constant volume (CV) CS Exp5b Minimum per IMC Provided but not required FCU -201- A VRF AIR HANDLER CORRIDOR Complex multi. zone system Heating and cooling Constant volume (CV) CS Exp5b Minimum per IMC Provided but not required FCU -001- B1 VRF AIR HANDLER CONFERENCE ROOM Complex multi zone system Heating and cooling Constant volume (CV) CS Exp5b Minimum per IMC Provided but not required FCU -002- B1 VRF AIR HANDLER MEDS Complex multi. zone system Heating and cooling Constant volume (CV) CS Exp5b Minimum per IMC Provided but not required FCU -003- B1 VRF AIR HANDLER OFFICE Complex multi. zone system Heating and cooling Constant volume (CV) CS Exp5b Minimum per IMC Provided but not required FCU -004- B1 VRF AIR HANDLER OBSERVATION Complex multi zone system Heating and cooling Constant volume (CV) CS Exp5b Minimum per IMC Provided but not required FCU -005- B1 VRF AIR HANDLER MEDS Complex multi zone system Heating and cooling Constant volume (CV) CS Exp5b Minimum per IMC Provided but not required FCU -006- B1 VRF AIR HANDLER STAFF ROOM Complex multi zone system Heating and cooling Constant volume (CV) CS Exp5b Minimum per IMC Provided but not required FCU -007- B1 VRF AIR HANDLER SERVERY Complex multi. zone system Heating and cooling Constant volume (CV) CS Exp5b Minimum per IMC Provided but not required FCU -008- B1 VRF AIR HANDLER MC LIVING Complex multi. zone system Heating and cooling Constant volume (CV) CS Exp5b Minimum per IMC Provided but not required FCU -009- B1 VRF AIR HANDLER MC LIVING Complex multi. zone system Heating and cooling Constant volume (CV) CS Exp5b Minimum per IMC Provided but not required FCU -010- B1 VRF AIR HANDLER MC LIVING Complex multi. zone system Heating and cooling Constant volume (CV) CS ElxpSb Minimum per IMC Provided but not required FCU -011- B1 VRF AIR HANDLER WASH DRY Complex multi. zone system Heating and cooling Constant volume (CV) CS Exp5b Minimum per IMC Provided but not required �n►8- otoq 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 FCU-101-VRF B1 AIR HANDLER CORRIDOR Complex multi. zone system Heating and cooling Constant volume (CV) CS Exp5b Minimum per IMC Provided but not required FCU -102- B1 VRF AIR HANDLER MULTIFUNCTION ROOM Complex multi. zone system Heating and cooling Constant volume (CV) CS Exp5b Minimum per IMC Provided but not required FCU -103- B1 VRF AIR HANDLER PUB Complex multi. zone system Heating and cooling Constant volume (CV) CS Exp5b Minimum per IMC Provided but not required ECU -104- B1 VRF AIR HANDLER MULTIPURPOSE ROOM Complex multi. zone system Heating and cooling Constant volume (CV) CS Exp5b Minimum per IMC Provided but not required FCU -105- B1 VRF AIR HANDLER MENS CLUB Complex multi. zone system Heating and cooling Constant volume (CV) CS Exp5b Minimum per IMC Provided but not required FCU -106- B2 VRF AIR HANDLER SALON Complex multi. zone system Heating and cooling Constant volume (CV) CS Exp5b Minimum per IMC Provided but not required FCU -107- B2 VRF AIR HANDLER KITCHEN Complex multi. zone system Heating and cooling Constant volume (CV) CS Exp5b Minimum per IMC Provided but not required FCU -108- B2 VRF AIR HANDLER PRIVATE DINING Complex multi. zone system Heating and cooling Constant volume (CV) CS Exp5b Minimum per IMC Provided but not required FCU -109- B2 VRF AIR HANDLER MARKETING UNIT Complex multi, zone system Heating and cooling Constant volume (CV) CS Exp5b Minimum per IMC Provided but not required FCU -110- B2 VRF AIR HANDLER MARKETING Complex multi. zone system Heating and cooling Constant volume (CV) CS Exp5b Minimum per IMC Provided but not required FCU -111- B2 VRF AIR HANDLER LIVING ROOM Complex multi. zone system Heating and cooling Constant volume (CV) CS (Exp5b Minimum per IMC Provided but not required FCU -112- B2 VRF AIR HANDLER CONFERENCE ROOM Complex multi. zone system Heating and cooling Constant volume (CV) CS (ExpSb Minimum per IMC Provided but not required FCU -113- B2 VRF AIR HANDLER OFFICES Complex multi, zone system Heating and cooling Constant volume (CV) CS (ExpSb Minimum per IMC Provided but not required FCU -114- B2 VRF AIR HANDLER COFFEE Complex multi. zone system Heating and cooling Constant volume (CV) CS (Exp5b Minimum per IMC Provided but not required FCU -201- B2 VRF AIR HANDLER CHAPEL Complex multi. zone system Heating and cooling Constant volume (CV) CS Exp5b Minimum per IMC Provided but not required FCU -202- B2 VRF AIR HANDLER GAME ROOM Complex multi. zone system Heating and cooling Constant volume (CV) CS Exp5b Minimum per IMC Provided but not required FCU -301- B2 VRF AIR HANDLER CORRIDOR LEVEL 3 Complex multi. zone system Heating and cooling Constant volume (CV) CS Exp5b Minimum per IMC Provided but not required FCU -302- B2 VRF AIR HANDLER PENTHOUSE Complex multi. zone system Heating and cooling Constant volume (CV) CS Exp5b Minimum per IMC Provided but not required FCU -301- C VRF AIR HANDLER CORRIDOR Complex multi. zone system Heating and cooling Constant volume (CV) CS Exp5b Minimum per IMC Provided but not required FCU -302- C VRF AIR HANDLER CORRIDOR Complex multi. zone system Heating and cooling Constant volume (CV) CS Exp5b Minimum per IMC Provided but not required FCU -303- C VRF AIR HANDLER CORRIDOR Complex multi. zone system Heating and cooling Constant volume (CV) CS Exp5b Minimum per IMC Provided but not required VRF-1 VRF CONDENSER VRF SYSTEM Complex multi. zone system Heating and cooling Constant volume (CV) CS Exp5b Minimum per IMC Provided but not required VRF-2 VRF CONDENSER VRF SYSTEM Complex multi. zone system Heating and cooling Constant volume (CV) CS Exp5b Minimum per IMC Provided but not required VRF-3 VRF CONDENSER VRF SYSTEM Complex multi. zone system Heating and cooling Constant volume (CV) CS Exp5b Minimum per IMC Provided but not required 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 VRF-4 VRF CONDENSER VRF SYSTEM Complex multi. zone system Heating and cooling Constant volume (CV) CS Exp5b Minimum per IMC Provided but not required MAU-1 PACKAGED UNIT KITCHEN MAKE-UP AIR Simple single zone system Heating and cooling Constant volume (CV) Yes Minimum per IMC Not Required MAU-2 PACKAGED UNIT KITCHEN MAKE-UP AIR Simple single zone system Heating and cooling Constant volume (CV) Yes Minimum per IMC Not Required FCU -1 SPLIT SYSTEM AIR HANDLER ELEVATOR MACHINE ROOM Simple single zone system Heating and cooling Constant volume (CV) SS Exp1 Minimum per IMC Not Required FCU -2 SPLIT SYSTEM AIR HANDLER POOL VAULT Simple single zone system Heating and cooling Constant volume (CV) SS Exp1 Minimum per IMC Not Required HP -1 SPLIT SYSTEM CONDENSER ELEVATOR MACHINE ROOM Simple single zone system Heating and cooling Constant volume (CV) SS Exp1 Minimum per IMC Not Required HP -2 SPLIT SYSTEM CONDENSER POOL VAULT Simple single zone system Heating and cooling Constant volume (CV) SS Exp1 Minimum per IMC Not Required PDU-1 SPLIT SYSTEM AIR HANDLER POOL Simple single zone system Heating and cooling Constant volume (CV) SS Exp2 Minimum per IMC Not Required PCU -1 SPLIT SYSTEM CONDENSER POOL Simple single zone system Heating and cooling Constant volume (CV) SS Exp2 Minimum per IMC Not Required VTHP-1 VERTICAL PACKAGE HEAT PUMP UNITS Simple single zone system Heating and cooling Constant volume (CV) SS Exp3 Minimum per IMC Not Required VTHP-2 VERTICAL PACKAGE HEAT PUMP UNITS Simple single zone system Heating and cooling Constant volume (CV) SS Exp3 Minimum per IMC Not Required PTHP-1 PACKAGE TERMINAL HEAT PUMP UNITS Simple single zone system Heating and cooling Constant volume (CV) SS Exp3 Minimum per IMC Not Required OAC -1 SPLIT SYSTEM CONDENSER ELECTRICAL ROOMS Simple single zone system Cooling only Constant volume (CV) CS Exp5a Not Applicable Not Required OAC -2 SPLIT SYSTEM CONDENSER ELECTRICAL ROOMS Complex multi zone system Cooling only Constant volume (CV) CS Exp5a Not Applicable Not Required OAC -3 SPLIT SYSTEM CONDENSER ELECTRICAL ROOMS Complex multi. zone system Cooling only Constant volume (CV) CS Exp5a Not Applicable Not Required RTU -1 PACKAGED UNIT MAIN DINING Complex single zone system Heating and cooling Constant volume (CV) Yes Minimum per IMC Not Required RTU -2 PACKAGED UNIT CORRIDOR Simple single zone system Heating and cooling Constant volume (CV) Yes Minimum per IMC Not Required Note 1 - Provide basic description of system terminal air conditioner or heat pump; make-up air system, ground or water Note 2 - If taking an exception to air economizer, exception are listed in MECH-ECONO. Note 3 - If ventilation "Not applicable" is selected, type, for example: unitary rooftop air handler, built-up centra unit heater, warm -air furnace, electric resistance heater, 4 -pipe -source heat pump, etc. select exception taken from drop down menu and complete provide explanation in Project Description box above. air handler;; single -packaged, fan coil, VRF system, energy MECH-ECONO form. Summary split system or packaged recovery air definitions handler, of each HVAC Hydronic Systems pump systems • Hydronic chilled water I Water -loop heat 0 No hydronic ❑ Hydronic heating • Geothermal Service Water Heating=' Systems Equipment Type (s) ❑ Hot water heating tank(s) ❑ Instantaneous Dedicated boiler , Heat exchange from space heat boiler or central hot water/steam Distribution Type (s) O Circulation System O On -demand water systems 0 No service Mechanical Schedules on plans then MECH-EQ forms are not required, listed in MECH-EQ tables. 0 Mechanical Plans • MECH-EQ Form Indicate location of equipment compliance information. If provided however, include on plans all applicable compliance information 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Design Load Calculations E Load calculation summary ❑ MECH-LOAD-CALC Form Provide design load calculations for all mechanical systems and equipment serving the building heating, cooling or ventilating needs. If a load calculation summary is provided with the permit documents that includes all applicable compliance information then the MECH-LOAD-CALC form is not required. 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Mechanical Summary, pg. 2 MECH-SUM 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Aug 2015 Fan Power © Project includes HVAC air distribution systems that provide heating and/or cooling If yes, provide a MECH-FANSYS -SUM form. o For one or more systems, the total fan motor nameplate hp of all fans in HVAC system exceeds 5hp. If yes, provide a seperate MECH-FANSYS form for each HVAC system exceeding the 5 horsepower threshold. Refer to Section C403.2.10 and MECH-FANSYS-DOC for requirements and exceptions. Commissioning Exception Summary Describe means of eligibilty for commissioning exception (capacity, etc) for all systems noted as taking exception in Mechanical Systems Summary table. Refer to Section C408.2 and C408.4 for exceptions. 4 Commissioning will be provided for heating Figure completion. all applicable systems Commissioning Exceptions: o Mechanical system(s) Service water system(s) For systems requiring commissioning, code official upon project C408.1.2.1 Commissioning Compliance Checklist shall be submitted to the Low Energy and Semi -Heated Spaces (Note 6 and 7) Space Type Location in Plan(s) Space(s) Served Area Served, square feet Heating Capacity, Btu/h (Note 4) Cooling Capacity, Btu/h (Note 5) Peak Space Conditioning Capacity, Btu/h-sf Compliance Check Notes Note 4 - Provide total installed heating output capacity of systems serving Low Energy or Semi -Heated space(s) in btuh. Note 5 - Provide total installed cooling capacity of system serving Low Energy space(s) 'n Btu/h. Not allowed for semi -heated spaces. Enter 0 if no cooling. Note 6 - Refer to Section C101.5.2 Low Energy Building. Intalled peak space conditioning capacity, heating or cooling, may not exceed 3.4 Btu/h-sf. Note 7 - Refer to Section C402.1.4 and Semi -Heated Space definition in Chapter 2. Total heating output capacity may not exceed 8 btuh/sf Only systems without electric resistance heating and no cooling are eligible for the wall insulation exception under semi -heated. 2012 Washington State Energy Code Compliance Forms for Commercial, Group 1, aFbE`� E DK R Boiler and Chiller Equipment Schedule 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 sto L L1 CH ies and - '7. . e 0 ' 1 Revisad -EQ Aug 2015 Project Info The following information shall be included in the mechanical equipment schedules in the permit documents. For projects without plans, provide the required information below. Project Address: QUAIL PARK AT RIVERTON CREEK DA{g/17/2018 13112 MILITARY ROAD S For B1QI{�i�RDaIpt�1S)et11f1 ��l!!ii ll1J ``�s City of Tukwila LLttJJ JJ DIVISION TUKWILA, WA 98168 Applicant Name: MATT BROOKS, P.E. Applicant Address: 21705 HIGHWAY 99, LYNNWOOD, WA Applicant Phone: 425-741-1200 BUILDING Boilers Equip. ID Make & Model Equipment Type Rated Heating Capacity, Btu/h Rated Efficiency (Note 1) Part Load Controls (Note 2) Burner Controls (Note 3) Notes 17:n LI,. ' 1-----, L ------ i_.....4 Note 1 - Provide rated efficiency in the units defined for he equipment in the WSEC efficiency table - AFUE, Et, or Ec Note 2 - Hydronic systems with capacity greater than 300,000 Btu/h are required to have part load controls capable of either automatic supply -water temperature reset or reduction of pump flow by 50% of design flow rate. Refer to C403.4.3.4 for details. Note 3 - Hydronic heating systems with capacity greater than 500,000 Btu/h shall have a multi -staged or modulating burner. Refer to C403.4.3 for details. Chillers Equip. ID Make & Model Equipment Type Rated Capacity (tons) (Note 4) Part Load Controls (Note 2) Non -Standard Calculation or Low Temp Exception (Note 5) Rated Full Load Effiaency (Note 6) Rated IPLV (Note 6) Compliance Path (Note 7) Note 4 - 1 ton = 12,000 Btu/h Note 5 - For water-cooled centri ugal chillers, indicate if minimum COP and NPLV is adjusted based on non-standard operating conditions per C403.2.3.1, or if chillers will be used in low temperature applications that are eligible for Table C403.2.3(7), Exception A. Note 6 - Provide rated efficiency in the units defined for the heating equipment in the WSEC efficiency table - EER, kW/ton, COP Note 7 - Indicate Compliance Path taken as defined in Table C403.2.3(7) Water Chilling Packages M►g— OK)cl CORMCT O! ! 'i rR # RECEIVED CITY OF TUKW►( i JAN 1 5 2019 r ERivlIT CENTE -, 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Heat Rejection Equipment Schedule MECH-EQ 2012 Washington State Enejgy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Aug 2015 Project Info The following information shall be included in the mechanical equipment schedules in the permit documents. For projects without plans, provide the required information below. Project Address: QUAIL PARK AT RIVERTON CREEK Date 12/17/2018 13112 MILITARY ROAD S For Building Dept. Use TUKWILA, WA 98168 Applicant Name: MATT BROOKS, P.E. pp Applicant Address: 21705 HIGHWAY 99, LYNNWOOD, WA Applicant Phone: 425-741-1200 Open and Closed Circuit Cooling Towers (Water Cooled Heat Rejection Equipment) Equip. ID Make & Model Equipment Type Fan Variable Flow Control At CTI Rated Conditions (Note 1) Tower Pump GPM Tower Fan HP GPM/HP (Note 2) Efficiency Compliance (Note 3) Note 1 - Open circuit towers - 95°F Entering Water, 85°F Leaving Water, 75°F Entering Air Wet Bulb Temperature Closed circuit towers - 102°F Entering Water, 90°F Leaving Water, 75°F Entering Air Wet Bulb Temperature Note 2 - Equipment performance at CTI rated conditions = Tower Pump GPM / Tower Fan HP Note 3 - To comply, water-cooled heat rejection equipment shall meet or exceed the minimum gpm flow rate per hp as defined in Table C403.2.3(8) when calculated at CTI rated conditions Air Cooled Condenser Equipment Equip. ID Make & Model Equipment Type At ARI Rated Conditions (Note 4) Heat Rejected (Btu/h) Condenser Fan HP Btu / h -HP (Note 5) Efficiency Compliance (Note 6) Note 4 - 125°F Condensing Temperature, R-22 Test Fluid, 190°F Entering Gas Temperature, 15°F Subcooling, 95°F Entering Air Dry Bulb Temperature Note 5 - Equipment performance at ARI rated conditions = Heat Rejected Btu/h / Condenser Fan HP Note 6 - To comply, air-cooled heat rejection equipment shall meet or exceed the minimum rate of heat rejection per hp as defined in Table C403.2.3(8) when calculated at ARI rated conditions. NO- oIoq CORREC ION Y P5 ..1 r. RECEIVED CITY OF TUKWILA JAN 1 5 2019 PERMIT CENTER 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Multiple Zone Air System Terminal Schedule MECH-EQ 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Aug 2015 Project Info The following information shall be included in the mechanical equipment schedules in the permit documents. For projects without plans, provide the required information below. Project Address: QUAIL PARK AT RIVERTON CREEK Date 12/17/2018 13112 MILITARY ROAD S For Building Dept. Use TUKWILA, WA 98168 Applicant Name: MATT BROOKS, P.E. Applicant Address: 21705 HIGHWAY 99, LYNNWOOD, W Applicant Phone: 425-741-1200 Equip. ID Maximum Airflow (cfm) Maximum Airflow During Reheating or Retooling (cfm) Ventilation (Note 1) Ventilation Standard Mininum Airflow (cfm) Basis of Compliance (Note 2) Note 1 - Indicate which standard governs the minimum ventilation requirement for the spaces(s) served and the required CFM. Note 2 - Se ect from drop down menu the basis of minimum airflow position for the VAV air terminal per the options defined in Section C403.4.5, or exception taken. All systems complying with IMC minimums that are required to utilize the multiple space iCTIO" ventilation equations shall provide calculations in the permit and final documents. COR p RECEIVED �1 M 14- oioq CITY OF TUKWILA r. JAN 1 5 2019 PERMIT CENTER 1:131N33 !I0,11:13ci 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Cooling & Heating Equipment Schedule, Page 1 MECH-EQ 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Au o 2015 Project Info The following information shall be included in the mechanical equipment schedules in the permit documents. For projects without plans, provide the required information below. Project Address: QUAIL PARK AT RIVERTON CREEK Date 12/17/2018 13112 MILITARY ROAD S For Building Dept. Use TUKWILA, WA 98168 Applicant Name: MATT BROOKS, P.E. Applicant Address: 21705 HIGHWAY 99, LYNNWOOD, WA Applicant Phone: 425-741-1200 Heating and/or Cooling Systems (Note 1) Cooling System Equip. ID Make & Model Area(s) Served WSEC Efficiency Table Equipment Type Condenser or Sub- Type Cooling Capacity, Btu/h (Note 2) Rated Efficiency (Note 3) Rated Part Load Efficiency (Note 4) Economizer exception - required higher efficiency V til w .. no C o I r r -n y �m� -7 0= -a %' r G7 o p . ' Note Eqter Equip ID, Make & Model, and Location of Service in this section for all heating & cool ng, cooling only and heating only equipment. Note 2 - Prdvide listed rated cooling capacity for rated equipment or design cooling capacity for unrated equipment. Note 3 - Fet rated equipment, provide listed `3(cd elticiency in the units defined for the equipment in the WSEC efficiency table - SEER, EER, SCOP, COP Om �• m csi c< N.) R m c �v —{ 32) Oft 0 co if 0 z 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Cooling & Heating Equipment Schedule, Page 2 MECH-EQ 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Aug 2015 Project Info The following information shall be included in the mechanical equipment schedules in the permit documents. For projects without plans, provide the required information below. Project Address: QUAIL PARK AT RIVERTON CREEK Date ######### 13112 MILITARY ROAD S For Building Dept. Use TUKWILA, WA 98168 Applicant Name: MATT BROOKS, P.E. Applicant Address: 21705 HIGHWAY 99, LYNNWOOD, WA Applicant Phone: 425-741-1200 Heating System Air System Equip. ID WSEC Efficiency Table Equipment Type Sub -type or Fuel Capacity, Btu/h (Note 5) Rated Efficiency (Note 6) Supply CFM Ventilation CFM Zone DCV or Occ. Sensors (Indicate type & zones(s) if required) Ventilation Energy Recovery (Yes or Not required) Note 4 - For rated equipment, provide listed rated part load efficiency IEER if required by code. Provide the rated low temperature EER for water source water -to -water heat pumps. Note 5 - Enter the rated cooling capacity for heat pumps, the listed rated heating capacity for all other rated equipment, or the design heating capacity for unrated equipment. Note 6 - For rated equipment, provide listed rated efficiency and, if applicable, the low temperature rated efficiency in the units defined for the heating equipment in the WSEC efficiency table - HSPF, COP, AFUE, E -t, E -c 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Mechanical Fan System Power Allowance MEC -FA - r S -SSW 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 sti riyca[uI.aLLF ,,. - - used ua 201 , Project Info Project Address: QUAIL PARK AT RIVERTON CREEK l+ JUL I:VMilj T/ kApa�if tel MILITARY ROAD S • For d n KY NY.13112 0 4 2019 City of Tukwila TUKWILA, WA 98168 •MAR Applicant Name: MATT BROOKS, P.E. Applicant Address: 21705 HIGHWAY 99, LYNNWOOD, WA Applicant Phone: 425-741-1200 HVAC Air Distribution System Schedule ; BUILDING DIVIJIVN List all HVAC systems that have the capability to provide heating and/or cooling to the spaces they serve. Fan System ID Speed Control (Note 1) Description System Total Nameplate HP (Note 2) Fan Power Calculation (Note 3) EF -1 CV RESTROOM LESS HPAN 1/4 < 5 hp EF -2 CV LAUNDRY LESS HP N 1/4 < 5 h EF -3 CV RESTROOM, 1 t" I :1 "' LESS (HPAN 1/4 < 5 h EF -4 CV RESTROOM -'-i -- tj •;„;i;_: =_,J• - LESS THAN 1/4 HP <5 hp EF -5 CV RESTROOM LESS HP N 1/4 < 5 hp EF -6 CV FITNESS LESS HPAN 1/4 < 5 hp EF -7 CV POOL LESS THAN N 1/4 < 5 hp EF -8 CV RESTROOM LESS HPAN 1/4 < 5 hp EF -9 CV JANITOR LESS HPAN 1/4 < 5 h EF -10 CV RESTROOM LESS HHAN 1/4 P < 5 hp EF -11 CV SERVERY LESS HP N 1/4 < 5 hp EF -12 CV LAUNDRY LESS HPAN 1/4 < 5 h EF -13 CV LAUNDRY LESS HP N 1/4 < 5 hp EF -14 CV SOILED LESS HPAN 1/4 < 5 hp EF -15 CV RESTROOM LESS HP N 1/4 < 5 hp EF -16 CV SALONHP LESS THAN 1/4 < 5 hp EF -17 CV DINING LESS THAN 1/4 HP < 5 h EF -18 CV ��ww y,� LAUNDRY RaCTI°N Vi � LESS THAN 1/4 HP < 5 hp EF -19 CV JANITOR i i+ LESS THAN 1/4 HP < 5 hp EF -20 CV JANITOR 1/4 HP < 5 hp EF -21 CV LAUNDRY LESS HHAN 1/4 P < 5 hp EF -22 CV JANITORHP RECEIVED LESS THAN 1/4 < 5 hp EF -23 CV LAUNDRY CITY OF TUKWILA LESS THAN 1/4 HP <5hp EF -24 CV LAUNDRY 14N.16MO LESS HPAN 1/4 < 5 h Mt- Ioq PERMIT CENTER 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 EF -25 CV LAUNDRYHP LESS THAN 1/4 < 5 hp KEF-1 CV KITCHEN HOOD 1/2 HP < 5 hp KEF-2 CV KITCHEN HOOD 3/4 HP < 5 hp KEF-3 CV KITCHEN HOOD 3/4 HP < 5 hp TSF -1 CV TRANSFER FAN LESS HPAN 1/4 < 5 hp SF -1 CV CORRIDOR LESS THAN 1/4 < 5 hp SF -2 CV MARKET LESS HPAN 1/4 < 5 hp SF -3 CV CHAPEL LESS HPAN 1/4 < 5 hp SF -4 CV CONFERENCE LESS HPAN 1/4 < 5 hp SF -5 CV MULTIFUNTION LESS THP N 1/4 < 5 hp SF -6 CV FCU -7,11,3,2 LESS THAN 1/4 < 5 hp SF -7 CV FCU -4,5,6 LESS THAN 1/4 < 5 hp Note 1 - Constant Volume (CV), Variable Air Volume (VAV), or Hospital/Lab CV system that qualifies for VAV budget per C403.2.10.1 Exception 1. Single zone VAV systems shall comply as CV. Note 2 - Enter the total nameplate hp of all fans associated with the delivery and removal of conditioned air by the system. Include all supply, return/relief, exhaust and exhaust hoods (>1 hp), make-up air, dedicated outside air (DOAS), booster fans, and series fan -powered terminals. VAV parallel fan -powered terminals and economizer relief fans do not need to be included if the fans do not operate at peak conditions. Note 3 - Indicate if MECH-FANSYS form is required (Yes), or the system is not required to provide this information because it has a combined total nameplate motor hp less than 5 hp (< 5 hp) or the system is ventilation only and thus has no heating or cooling capacity (No). MECH-FANSYS Forms A MECH-FANSYS form shall be provided for each system with total nameplate hp greater than 5 hp. Select (Add Fan System Form) to generate an additional form. Added forms can be deleted with button in cell E38 of the added 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Mechanical Fan System Power Allowance MECH-FANSYS 2012 Washington State Energy Code Compliance Forms for Commercial Buildings in Project Info Project Address: QUAIL PARK AT RIVERTON CREEK Date 12/17/2018 13112 MILITARY ROAD S For Building Dept. Use TUKWILA, WA 98168 Applicant Name: MATT BROOKS, P.E. Applicant Address: 21705 HIGHWAY 99, LYNNWOOD, WA Applicant Phone: 425-741-1200 Fan System ID A separate MECH-FANSYS form must be completed for every HVAC system that exceeds the 5hp threshold. System Supply Fan Speed Control Constant Volume (CV), Variable Air Volume (VAV), or Hospital/Lab CV system that qualifies for VAV budget per C403.2.10.1, Exception 1 Compliance Option Compliance is based upon either the fan motor nameplate horse power (Option 1) or the fan brake horsepower (Option 2). The bhp calculation provides adjustments for special equipment per Tabl C403.2.13.1(2). Fan S stem Supply Y PP Y CFM Total - Provide maximum design supply airflow rate (CFM) of all supply fans serving the conditioned space in Fan Equipment Schedule below. Fan System CFM Total is the supply airflow of the central air handler at peak design conditions. Additional volumetric air flow provided at zone fan terminals, booster fans, or through induction is not included in the supply CFM total. However, the fan power of this equipment is included in the HP and BHP calculations. Fan Equipment Schedule Fan ID and Location Fan Type Quantity of Fan Type Total CFM . (Note 1) Total Nameplate HP (Note 2) Total BHP (Note 3) Note 1 - Total CFM is the maximum CFM of the listed fan(s) when operating at peak design operating conditions. Note 2 - Total namplate hp of the listed fan(s). Note 3 - Total brake horsepower (bhp) of the listed fan(s) at peak design operating conditions. Not required if Nameplate HP compliance option chosen. Compliance Message: Total Proposed: Total Allowance: Brake Horsepower Allowance Adjustments Device Type Description and Location CFM thorough this device (CFMD) Assigned Pressure Drop, PD in w.c. (Note 5) Calculated Pressure Drop, PD in w.c. (Note 6) Adjustment, A in bhp (Note 7) Note 4 - Bhp allowance for energy recovery devices and run around coil loops includes both air Total Adjustment (bhp): streams. so the CFMD is the sum of the sunnly CFM anri arha,,cr CFAs if hnfh nn fhrn, ,nh the device. Note 5 - Assigned pressure drop (PD) adjustment per Table C403.2.10.1(2). Note 6 - Pressure drop (PD) adjustment shall be calculated per the applicable method defined in Table C403.2.10.1(2) based on specific system conditions. Note 7 - A = PD * CFMD/4131 where A is the allowed system brake horse power adjustment, PD is pressure drop allowance, and CFMD is the cfm through the device. 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 General Instructions: A. Include all fans directly associated with the delivery and removal of conditioned air to the zones served by the system. Enter CFM and brake horsepower (bhp) of each fan at peak design conditions and the nameplate horsepower (hp). Include supply, return and relief fans, exhaust and exhaust hood fans (>1 hp), booster fans and fans included as part of make-up air units, dedicated outside air systems(DOAS), energy recovery ventilators (ERV), and series fan -powered terminal equipment. B. VA V parallel fan -powered terminals and economizer relief fans do not need to be included if the fans do not operate at peak conditions. C. Fans not directly associated with the delivery and removal of conditioned air, such as condenser fans, do not need to be included in the fan power total. D. Fan power calculations are not required for non -central air HVAC systems such as 4 -pipe fan coils and variable refrigerant flow (VRF) systems unless individual fan systems are greater than 5hp. E. In the Brake Horsepower Allowance Adjustments table, if a Device Type is selected that has an Assigned Pressure Drop, this value will autofill into the Assigned Pressure Drop cell and the Calculated Pressure Drop cell will be write -protected. If the Device Type requires a Calculated Pressure Drop, then enter this value into the Calculated Pressure Drop cell and the Assigned Pressure Drop cell with be write -protected. F. Refer to FAQ section of MECH-FANSYS-DOC for additional instructions. 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Fan Power Allowance Adjustment Factors 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 MECH-FANSYS-DOC Revised Aug 2015 TABLE C403.2.10.1(2) FAN POWER LIMITATION PRESSURE DROP ADJUSTMENT Device Adjustment Credits Fully ducted return and/or exhaust air systems 0.5 inch w.c. (2.15 inches w.c. for laboratory and vivarium systems) Return and/or exhaust air flow control devices 0.5 inch w.c. Exhaust filters, scrubbers, or other exhaust treatment The pressure drop of device calculated at fan system design condition Particulate filtration credit: MERV 9 - 12 0.5 inch w.c. Particulate filtration credit: MERV 13 - 15 0.9 inch w.c. Particulate filtration credit: MERV 16 and greater and electronically enhanced filters Pressure drop calculated at 2x clean filter pressure drop at fan system design condition Carbon and other gas -phase air cleaners Clean filter pressure drop at fan system design condition Biosafety cabinet Pressure drop of device at fan system design condition Energy recovery device, other than coil runaround loop (2.2 x energy recovery effectiveness) — 0.5 inch w.c. for each airstream Coil runaround loop 0.6 inch w.c. for each airstream Evaporative humidifier/cooler in series with another cooling coil Pressure drop of device at fan system design conditions Sound attenuation section 0.15 inch w.c. Exhaust system serving fume hoods 0.35 inch w.c. Laboratory and vivarium exhaust systems in high-rise buildings 0.25 inch w.c./100 feet of vertical duct exceeding 75 feet w.c.: water column. For SI: 1 inch w.c.: 249 Pa, 1 inch.= 25.4 mm. 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Design Load Calculation Summary WEC--LOAD-CALC 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 • cy q. -1 ; �_ i _ • 201f Project The following included in summary documents. summary required information Info information shall be Project Address: QUAIL PARK AT RIVERTON CREEK i VUa ��Cn�717^f'OG� II 13112 MILITARY ROAD S Fo ildir> y1D MAR 0 2019 City of Tukwila the load calculation program submitted with the permit If a load calculation is not available, provide the below. TUKWILA, WA 98168 Applicant Name: MATT BROOKS, P.E. Applicant Address: 21705 HIGHWAY 99, LYNNWOOD, WA Applicant Phone: 425-741-1200 Equip. ID Area(s) Served Heating Design Load - Btu/h (Note 1) Cooling Design Load - Btu/h (Note 1) Calculation Metho (Note 2) b ILDING DIVISION Notes FCU -0P2 -A FITNESS 29,500 37,300 COMPUTER LOAD CALCULATION PROGRAM FCU -002-A EAL DINING 18,900 36,500 COMPUTER LOAD CALCULATION PROGRAM FCU -003-A FITNESS 14,300 39,400 COMPUTER LOAD CALCULATION PROGRAM FCU -201-A CORRIDOR 9,000 23,800 COMPUTER LOAD CALCULATION PROGRAM FCU -001- 61 CONFERENCE ROOM 9,470 6,900 COMPUTER LOAD l CALCULATION,, ,a PROGRAM f` Li ) ,, FCU -002- B1 MEDS 1,290 3,160 COMPUTER LOAD CALCULATION PROGRAM FCU -003- 61 OFFICE 1,390 2,720 COMPUTER LOAD CALCULATION PROGRAM FCU -004- B1 OBSERVATION 1,290 2,540 COMPUTER LOAD CALCULATION PROGRAM FCU -005- B1 MEDS 2,620 5,030 COMPUTER LOAD CALCULATION PROGRAM FCU -006- 61 STAFF ROOM 5,760 9,580 COMPUTER LOAD CALCULATION PROGRAM FCU -007- Bi SERVERY 5,880 21,300 COMPUTER LOAD CALCULATION PROGRAM FCU -008- B1 MC LIVING 15,833 34,000 COMPUTER LOAD CALCULATION PROGRAM FCU -009- B1 MC LIVING 15,833 34,000 COMPUTER LOAD CALCULATION PROGRAM CORRECT!' FCU -010- B1 MC LIVING 15,833 34,000 COMPUTER LOAD CALCULATION PROGRAM Y t'► # I r-i a+ FCU -011- Bi WASH DRY 1,770 8,290 COMPUTER LOAD CALCULATION PROGRAM FCU -101- B1 CORRIDOR 7,030 11,900 COMPUTER LOAD RECEIVED CALCULATION CITY oF rVKw PROGRAM FCU -102- B1 MULTIFUNCTION ROOM 11,700 15,800 COMPUTER LOAD CALCULATION JAN 1 5 2019 PROGRAM Mt9- o�oq ILA HERMIT CENTER 2012 Washington State Energy Code Compliance Forms for Commercial FCU -103- B1 PUB 15,500 25,400 COMPUTER LOAD CALCULATION PROGRAM FCU -104- Bi MULTIPURPOSE ROOM 12,900 22,800 COMPUTER LOAD CALCULATION PROGRAM FCU -105- 61 MENS CLUB 9,690 18,500 COMPUTER LOAD CALCULATION PROGRAM FCU -106- B2 SALON 22,000 22,600 COMPUTER LOAD CALCULATION PROGRAM FCU -107- B2 KITCHEN 38,600 69,100 COMPUTER LOAD CALCULATION PROGRAM FCU -108- B2 PRIVATE DINING 2,640 6,030 COMPUTER LOAD CALCULATION PROGRAM FCU -109- B2 MARKETING UNIT 5,700 8,070 COMPUTER LOAD CALCULATION PROGRAM FCU -110- B2 MARKETING 8,030 16,300 COMPUTER LOAD CALCULATION PROGRAM FCU -111- B2 LIVING ROOM 37,000 56,500 COMPUTER LOAD CALCULATION PROGRAM FCU -112- B2 CONFERENCE ROOM 5,220 7,030 COMPUTER LOAD CALCULATION PROGRAM FCU -113- B2 OFFICES 6,170 7,380 COMPUTER LOAD CALCULATION PROGRAM FCU -114- B2 COFFEE 29,300 25,900 COMPUTER LOAD CALCULATION PROGRAM FCU -201- B2 CHAPEL 6,650 11,900 COMPUTER LOAD CALCULATION PROGRAM FCU -202- B2 GAME ROOM 6,890 11,800 COMPUTER LOAD CALCULATION PROGRAM FCU -301- B2 CORRIDOR LEVEL 3 9,000 23,800 COMPUTER LOAD CALCULATION PROGRAM FCU -302- B2 PENTHOUSE 19,700 31,300 COMPUTER LOAD CALCULATION PROGRAM FCU -301-C CORRIDOR 15,390 23,310 COMPUTER LOAD CALCULATION PROGRAM FCU -302-C CORRIDOR 9,560 12,160 COMPUTER LOAD CALCULATION PROGRAM FCU -303-C CORRIDOR 24,060 36,900 COMPUTER LOAD CALCULATION PROGRAM RTU -1 DINNING 104,000 104,000 COMPUTER LOAD CALCULATION PROGRAM RTU -2 CORRIDOR 23,700 18,400 COMPUTER LOAD CALCULATION PROGRAM 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Note 1 - Design load shall account for the building envelope, lighting, ventilation and occupancy loads of the space(s) served by the mechanical system. Heating and cooling loads shall be adjusted to account for load reduction achieved by an energy recovery system, if applicable. Note 2 - Computer load calculation program, worksheet (identify source), or equivalent computation procedure in accordance with ASHRAE Standard 183. 7 City of Tukwila Allan Ekberg, Mayor Department of Community Development - Jack Pace, Director April 1, 2020 Citizen Design 10 Dravus Street Seattle, WA 98109 RE: Request for Application Extension #3 Permit Number M18-0109 Dear Citizen Design, This letter is in response to your written request for an extension to Application Number M18-0109. The Building Official, Jerry Hight, has reviewed your letter and considered your request to extend the above referenced permit. It has been determined that the City of Tukwila Building Division will be granting an extension to the permit application through September 8, 2020. If you should have any questions, please contact our office at (206) 431-3670. Sincerely, Bill Rambo Permit Technician Pile: Permit No. M18-0109 Tukwila City Hall • 6200 Southcenter Boulevard • Tukwila, WA 98188 • 206-433-1800 • Website: TukwilaWA.gov Ai9 CITIZEN DESIGN INFO (AT) C0LLAB0RATIVEC0.COM 206.535.7908 WE ARE FAMILY DESIGNING INSPIRED SPACE TO CREATE COMMUNITY • • March 3, 2020 Jerry Hight Tukwila Community Development Department 6300 Southcenter Boulevard #100 Tukwila, WA 98188 Dear Mr. Hight, We are writing today to request an additional extension to the building, electrical, mechanical and plumbing permits for the Quail Park of Tukwila project per our discussion in December. You indicated your preference for us to delay pulling the permit and submitting a post -permit revision. The permit numbers are D 16- 0184, EL 18-0745, M 18-0109 and PG 18-0110, respectively. These permits are due to expire on March 8, 2020. Revisions to the parent building permit, D 16-0184, have been completed and are to be submitted as a part of this request [Friday, March 6]. Granting an extension to the building permit will allow it to remain active while these revisions are reviewed by city officials. Extending the trade permits will allow them to be revised as necessary and drawn after the revisions to the building permit are approved. If you have any questions or need additional information, please feel free to contact our office. We look forward to continuing to work together as this project moves forward. Humbly submitted, Citizen Design Reques for Permit Application Extension # 1 -rant Expiration Date:— 1(49-6 (I Extension Request: Approved for /e"-- LI Denied (provide explanation) Signature/Initials RECEIVED CITY OF TUKWILA MAR 0 60 PERMIT CENTER 0 City of Tukwila Allan Ekberg, Mayor Department of Community Development - Jack Pace, Director August 14, 2019 Scott Chritton 1711 Port Dr Burlington, WA 98233 RE: Request for Permit Application Extension #2 Permit Number M18-0109 Dear Scott Chritton, This letter is in response to your written request for an extension to Application Number m18-0109. The Building Official, Jerry Hight, has reviewed your letter and considered your request to extend the above referenced permit. It has been determined that the City of Tukwila Building Division will be granting an extension to the permit application through February 28, 2020 If you should have any questions, please contact our office at (206) 431-3670. Sincerely, tt a .6e (.1e__J Kandace Nichols Permit Technician File: Permit No. M18-0109 Tukwila City Hall • 6200 Southcenter Boulevard • Tukwila, WA 98188 • 206-433-1800 • Website: TukwilaWA.gov August 5, 2019 City Of Tukwila 6300 Southcenter Boulevard Suite #100 Tukwilla, WA 98188 Re: Permit Application #M18-0109 Quail Park At Riverton Creek 13112 Military Road South DEAR KANDACE NICHOLS, MECHANICAL, INC. 1711 PORT DRIVE, BURLINGTON, WA 98233 P11: (360) 757-6909 FX: (360) 757-6919 We received you letter dated 6/28/19 regarding the expiration of the permit on 8/28/19. We are requesting an extension of the permit. This project has been delayed due to funding. I received a call from Collaborative Construction letting us know that the project may still have life. Please contact me if this request is declined so we can decide who will pay before the expiration date. Please call with any questions. Thank you, Scott Chritton Owner R&H Mechanical, Inc. scottarhmech.com 360.757.6909 Request for Extensior #a Current Expiration Date: ?' Zg" B 9 Extension Request: Approved for / t 6 days nied�(proe explanation) mac./`,�s Signature-'nitials JIV 6/28/2019 0 II City of Tukwila Department of Community Development SCOTT CHRITTON 1711 PORT DR BURLINGTON, WA 98233 RE: Permit Application No. M18-0109 QUAIL PARK AT RIVERTON CREEK 13112 MILITARY RD S Dear SCOTT CHRITTON, Allan Ekberg, Mayor Jack Pace, Director In reviewing our current application files, it appears that your permit applied for on 8/28/2018, has not been issued by the City of Tukwila Permit Center. Per the International Building Code, Intemational Mechanical Code, Uniform Plumbing Code and/or National Electrical Code every permit application not issued within 180 days from the date of application shall expire and become null and void. Currently your application has a status of APPROVED and is due to expire on 8/2812019. If you still plan to pursue your project, you are hereby advised to do one of the following: 1) If the plan review is complete for the project and your application is approved, you may pick up the application before the date of expiration. At the time of permit issuance the expiration date will automatically be extended 180 days. -or- 2) If the plan review is not completed submit a written request for application extension (7) seven days in advance of the expiration date. Address your extension request to the Building Official and state your reason(s) for the need to extend your application. The Building Code does allow the Building Official to approve one extension of up to 90 days. If it is determined that your extension request is granted, you will be notified by mail. In the event that we do not receive your written request for extension or request is denied, your permit application will expire and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sin erely, o GIAA.A4-et Ale-cii j Kandace Nichols Permit Technician File No: M18-0109 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 • • City of Tukwila • Departawni of Community Development 6300 Southi enter Boulevard, sum #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov REVISION SUBNIIITAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mall, faxetc. Date: Plan Cheek/Permit Number: M18-0109 ❑ Response to Incomplete Letter # Response to Correction Letter # Z ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner ❑ Deferred Submittal # Project Name: Quail Park at Riverton Creek Project Address 13112 Military Rd S Contact Person: s� Summary of Revision: Phone .Number: 2-Q( TT (-' (-9 9 REGO KWILS CITY OF TU FE PERMIT CENTER Sheet Number(s): 'Cloud" or highlight all areas of revision including dam of rev n Receival at the City of Tukwila Permit Center by: Entered in TRAKiT on "f 0 City of Tukwila • Allan Ekberg, Mayor Department of Community Development - Jack Pace, Director February 25, 2019 Scott Chritton 1711 Port Dr Burlington, WA 98233 RE: Request for Extension #1 Permit Number M18-0109 Dear Mr. Chritton, This letter is in response to your written request for an extension to Permit M18-0109. The Building Official, Jerry Hight, has reviewed your letter and considered your request to extend the above referenced permit. It has been determined that the City of Tukwila Building Division will be granting an extension to the permit through August 28, 2019. If you should have any questions, please contact our office at (206) 431-3670. Sincerely, Jazzel Salazar Permit Technician File: Permit No. M18-0109 Tukwila City Hall • 6200 Southcenter Boulevard • Tukwila, WA 98188 • 206-433-1800 • Website: TukwilaWA.gov February 18, 2019 T • VIGATOR DEVELOPMENT GROUP Jerry Hight, Building Official City of Tukwila Department of Community Development 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 RE: Permit Applications: D16-0184, EL18-0745, M18-0109 & PG18-0110 Quail Park at Riverton Creek 13112 Military Rd South Mr. Flight: In November 2018 we requested and were granted an extension of our Development permit D16- 0184 till June 8, 2019. Our associated MEP permits however are scheduled to expire on February 28th, 2019. We request an extension for the MEP permits and any other associated permits until the June 8th date so that all the permits are on the same timing since we will not be able to start work on any of the associated permits until we pull the Development permit. This would include the following permits with expiration dates that we are aware of: EL18-0745 — Our understanding is that the plans have been approved. M18-0109 —Still in plan check. We are in the process of submitting what we hope will be the final round of corrections. PG18-0110 — Still in plan check. We are in the process of submitting what we hope will be the final round of corrections. If there are any questions regarding this request or other items, we should be aware of, please contact me directly. My contact information is listed below. Thank you for your consideration, Denis Bryant, President Navigator Development Group 146 N Canal St, Suite 220 Seattle, WA 98103 Office: (206) 441-1770 Cell: (206) 465-2733 Request for Extensio: # Current Expiration Date: `/I lG �� i Extension Request: Approved for /r() days Den ied (provide explanation) Signature nitials 1246 N Canal St, Ste 220 Seattle, WA 98103 office 206.441.1770 fax 206.441.1977 navigatordg.com 1/2/2019 ® • City of Tukwila Department of Community Development SCOTT CHRITTON 1711 PORT DR BURLINGTON, WA 98233 RE: Permit Application No. M 18-0109 QUAIL PARK AT RIVERTON CREEK 13112 MILITARY RD S Dear SCOTT CHRITTON, Allan Ekberg, Mayor Jack Pace, Director In reviewing our current application files, it appears that your permit applied for on 8/28/2018, has not been issued by the City of Tukwila Permit Center. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or National Electrical Code every permit application not issued within 180 days from the date of application shall expire and become null and void. Currently your application has a status of COMMENTS OUT and is due to expire on 2/28/2019. If you still plan to pursue your project, you are hereby advised to do one of the following: 1) If the plan review is complete for the project and your application is approved, you may pick up the application before the date of expiration. At the time of permit issuance the expiration date will automatically be extended 180 days. -or- 2) If the plan review is not completed submit a written request for application extension (7) seven days in advance of the expiration date. Address your extension request to the Building Official and state your reason(s) for the need to extend your application. The Building Code does allow the Building Official to approve one extension of up to 90 days. If it is determined that your extension request is granted, you will be notified by mail. In the event that we do not receive your written request for extension or request is denied, your permit application will expire and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: M18-0109 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 • • City of Tukwila REVISION SUBMITTAL Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206431-3670 Web site: http://www.TukwilaWA.gov Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: Plan Check/Permit Number: M1 8-0109 ❑ Response to Incomplete Letter # ® Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner ❑ Deferred Submittal # Project Name: Quail Park at Riverton Creek Project Address: 13112 Military Rd S Contact Person: Phone Number: Summary of Revision: RECEIVED CITY OF TUKWILA PERMIT CENTER Sheet Number(s): "Cloud" or highlight all areas of revision including e of revision ived at the City of Tukwila Permit Center by: Entered in TRAKiT on -11--1 qI CAUserdbilk1Desktopdtevision Submittal Fotn.doc Revised: Au$un 2015 ( / N EMERALD CITY ENGINEERS, INC. 21705 Highway 99 Lynnwood, WA 98036 (425)741-1200 / fax (425) 741-1201 December 17, 2018 TO: Bill Rambo City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 (206) 431-3670 FROM: Matt Brooks, P.E. Emerald City Engineers, Inc. 21705 Highway 99, Lynnwood, WA 98036 (425) 741-1200 Project: Quail Park 13112 Military Road South, Tukwila, WA 98168 Permit #: M18-0109 Subject: City of Tukwila Dept. of Community Development Comments — Mech Responses The purpose of this memo is to provide narrative responses to plan check review comments. Emerald City Engineers responses to comments are in bold print. Discussion: Corrections #1: (BUILDING REVIEW NOTES) 1. The plan shows kitchen exhaust hood ducts with long lengths of ducts extending around the interior of the units to terminate to the exterior. Some of the ducting shown has several 45 and 90 degree turns. Provide hood manufacturer's specifications to show the duct sizing to lengths of duct with the number of elbows allowed. Include dimensions for length and size of ducts. ECE response: Hood specifications and calculations added to sheet M4.02. 2. Type 1 hood shall be a separate permit with complete details and manufacturer's installation information. Details shall include construction of shafts and roof penetrations. ECE response: Note added to M0.00 3. Provide manufacturer's specification and UL listings for all proposed fire smoke dampers. ECE response: Damper cutsheet to be added to sheet M4.02 C 0 R RICi'{p1J 4. Provide a completed 2015 Washington State Energy Code "MECHANICAL SUMMARY" Compliance Form for Commercial Buildings, available online at: http://www.neec.net/energy-codes (scroll down to center of page "2015 WSEC Commercial Provisions - Compliance Forms"). ECE response: Forms attached to response document 5. WSEC requires the commissioning of new buildings. State provides a Fact Sheet where you can see if you qualify for commissioning for Electrical, Mechanical, Plumbing systems. To verify the requirements, here is the link to the fact sheet. https://www.neec.net/wp-content/uploads/2017/1 I /WSEC-Commis ;i4riptinVI ladf ECE response: Commissioning notes added to M0.02. VA1?- oi 0q CITY OF TUK`'WILA JAN 152019 PERMIT CENTER Page 2 of 2 December 17, 2018 6. Applicable Code Notes reference 2012 International Conservation Codes. Revised to reference compliance with 2015 Washington State Energy Codes with Amendments. ECE response: Building is under the 2012 codes per Jerry Height call with Mack Selberg of Ankrom Moisan on 7/16/18. 7. On sheet M2.00B, between grid 13 and AP, duct penetration does not indicate Fire Smoke Dampers in the corridor. On sheet M3.05 the FSD's are shown. For consistency show the same on sheet M2.00B. ECE response: FSD labels added to sheet M2.00B from M3.05. 8. Beauty -hair and nail salons with manicure pedicure stations shall require separate mechanical exhaust and ventilation systems. For clarification, specify the specific use of the salon and type of ventilation that shall be provided for the salon that complies with IMC TABLE 403.3.1.1, and Section 403.2.1, Item 3. ECE response: Salon 135 is equipped with 400 CFM of dedicated exhaust with EF - 16 per 2012 mechanical code for 0.6 CFM/sf. There is also a portable source capture exhaust system for the salon. 9. The kitchen is shown with Type I hoods. Type I hoods and exhaust system shall be a separate permit with full details of the hood, duct assembly and exhaust/make up air system including all installation specifications with details. Please clarify. ECE response: Note added to M0.00. 10. Walk -in -coolers and freezers that are hardwired shall be a separate mechanical permit. For information only. ECE response: Note added to M0.00. 11. It is assumed the corridor smoke removal and air pressurization of stairwells and elevators are a separate permit. Please clarify and note on cover sheet. ECE response: Pressurization is not required for a 4 -story building. END OF MEMORANDUM City of Tukwila Department of Community Development September 11, 2018 SCOTT CHRITTON 1711 PORT DR BURLINGTON, WA 98233 RE: Correction Letter # 1 MECHANICAL Permit Application Number M18-0109 QUAIL PARK AT RIVERTON CREEK - 13112 MILITARY RD S Dear SCOTT CHRITTON, Allan Ekberg, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING - M DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments. • (GENERAL INFORMATION NOTE) PLAN SUBMITTALS: (Min. size 11x17 to a preferably maximum size of24x36; all sheets shall be the same size; larger sizes may be negotiable. "New revised"'plan sheets shall be the same size sheets as those previously submitted.) "STAMP AND SIGNATURES" (If applicable) For Engineers: "Every page of a plan set must contain the seal/stamp, signature of the licensee(s) who prepared or who had direct supervision over the preparation of the work, and date of signature. Specifications that are prepared by or under the direct supervision of a licensee shall contain the seal/stamp, signature of the licensee and the date of signature. If the "specifications" prepared by a licensee are a portion of a bound specification document that contains specifications other than that of an engineering or land surveying nature, the licensee need only seal/stamp that portion or portions of the documents for which the licensee is responsible." It shall not be required to have each page of "specifications" (calculations) to be stamped and signed; Front page only will be sufficient (WAC 196-23-010 & 196-23-020). Architects: "date" only not required (WAC 308-12-081). (BUILDING REVIEW NOTES) 1. The plan shows kitchen exhaust hood ducts with long lengths of ducts extending around the interior of the units to terminate to the exterior. Some of the ducting shown has several 45 and 90 degree turns. Provide hood manufacturer's specifications to show the duct sizing to lengths of duct with the number of elbows allowed. Include dimensions for length and size of ducts. 2. Type I hood shall be a separate permit with complete details and manufacturer's installation information. Details shall include construction of shafts and roof penetrations. 3. Provide manufacturer's specification and UL listings for all proposed fire smoke dampers. 4. Provide a completed 2015 Washington State Energy Code "MECHANICAL SUMMARY" Compliance Form for Commercial Buildings, available online at: http://www.neec.net/energy-codes (scroll down to center of page "2015 WSEC Commercial Provisions - Compliance Forms"). 5. WSEC requires the commissioning of new buildings. State provides a Fact Sheet where you can see if you qualify for commissioning for Electrical, Mechanical, Plumbing systems. To verify the requirements, here is the link to the fact sheet. https://www.neec.net/wp-content/uploads/2017/ 1 1 /W SEC -Commissioning- 10-20 17- 1 .pdf 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 i \ 6. Applicable Code Note.. _ sference 2012 International Conservation Codes..<evised to reference compliance with 2015 Washington State Energy Codes with Amendments. 7. On sheet M2.00B, between grid 13 and AP, duct penetration does not indicate Fire Smoke Dampers in the corridor. On sheet M3.05 the FSD's are shown. For consistency show the same on sheet M2.00B. 8. Beauty -hair and nail salons with manicure pedicure stations shall require separate mechanical exhaust and ventilation systems. For clarification, specify the specific use of the salon and type of ventilation that shall be provided for the salon that complies with IMC TABLE 403.3.1.1, and Section 403.2.1, Item 3. 9. The kitchen is shown with Type I hoods. Type I hoods and exhaust system shall be a separate permit with full details of the hood, duct assembly and exhaust/make up air system including all installation specifications with details. Please clarify. 10. Walk -in -coolers and freezers that are hardwired shall be a separate mechanical permit. For information only. 11. It is assumed the corridor smoke removal and air pressurization of stairwells and elevators are a separate permit. Please clarify and note on cover sheet. Note: Contingent on response to these corrections, further plan review may request for additional corrections. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. Sincerely, -2)A-P Bill Rambo Permit Technician File No. M18-0109 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 1 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M18-0109 DATE: 02/22/19 PROJECT NAME: QUAIL PARK AT RIVERTON CREEK SITE ADDRESS: 13112 MILITARY RD S Original Plan Submittal X Response to Correction Letter # 2 Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: fklA) 104°1 Building Division Public Works n Fire Prevention Structural Planning Division ❑ Permit Coordinator PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 02/26/19 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 03/26/19 Approved Approved with Conditions n Corrections Required n Denied n (corrections entered in Reviews) (ie: Zoning Issues) lYait(1 Nota ion: OI &1 V 1 Y `I ` V l�f �\OZ REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 COORD COP( 0 PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M18-0109 DATE: 1/15/19 PROJECT NAME: QUAIL PARK AT RIVERTON CREEK SITE ADDRESS: 13112 MILIATRY RD S Original Plan Submittal Revision # before Permit Issued X Response to Correction Letter # 1 Revision # after Permit Issued DEPARTMENTS: Pr) t6 t4 Building Division el Public Works Fire Prevention Structural Li Planning Division nPermit Coordinator II PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 1/17/19 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) DUE DATE: 2/14/19 Approved with Conditions n Denied (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 'PERMIT COORD COPY `- PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M18-0109 DATE: 08/28/18 PROJECT NAME: QUAIL PARK AT RIVERTON CREEK SITE ADDRESS: 13112 MILITARY RD S X Original Plan Submittal Response to Correction Letter # Revision # Revision # before Permit Issued after Permit Issued DEPARTMENTS: crJcW�I Building Division Public Works A -1A 4WC, 61-11-18 Fire Prevention Structural Planning Division nPermit Coordinator PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 08/30/18 Structural Review Required REVIEWER'S INITIALS: DATE: n APPROVALS OR CORRECTIONS: Approved Approved with Conditions Corrections Required (corrections entered in Reviews) Denied (ie: Zoning Issues) DUE DATE: 09/27/18 n n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only q �j CORRECTION LETTER MAILED: 4y11 V Departments issued corrections: Bldg h Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 R & H MECHANICAL INC Washington State Department of Labor & Industries Hoene Espanol Contact Safety & Health Claims & Insurance Search L&I Page 1 of 2 A-Zlndex Help My LC.1 Workplace Rights Trades & Licensing 1 R & H MECHANICAL INC Owner or tradesperson Principals CHRITTON, VIRGIL SCOTT, PRESIDENT Doing business as R & H MECHANICAL INC WA UBI No. 600 311 146 1711 PORT DR BURLINGTON, WA 98233 360-757-6909 SKAGIT County Business type Corporation ILicense Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. RHMECI*951 LC Effective — expiration 06/03/2005— 07/19/2019 Bond CBIC Bond account no. SF2795 Active. Meets current requirements. $12,000.00 Received by L&I Effective date 03/18/2009 04/12/2009 Expiration date Until Canceled Insurance American Fire & Casualty Co Policy no. BKA56118156 $1,000,000.00 Received by L&I Effective date 07/09/2018 07/10/2018 Expiration date 07/10/2019 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. https://secure.lni.wa.gov/verify/Detail.aspx?UBI=600311146&LIC=RHMECI*951 LC&SAW= 3/5/2019 Help us improve