Loading...
HomeMy WebLinkAboutPP - 17300 WEST VALLEY HWY - LEAVITT MACHINERY USA INC - PERMITS AND PLANS17300 WEST VALLEY HWY ASSOCIATED PERMITS 17-S-159 10-5-097 96-S-307 06-F-053 93-F-240 l INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: eCt t/i r rnaceJb t Sprinklers: Type of Inspection: e6 -- yContact Address: Suite#: /73 W V f-( Monitor: Person Special Instructions: Occupancy Type: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: 5i3.(,/icterz- NeedsShift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: 7 j' �,�...-- Date:q/22�/� Hrs.: I $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 CORRECTION NOTICE/REINSPECT1uN FEE Inspector: Permit number: TUKWILA FIRE MARSHAL'S OFFICE Office: 206-575-4407 Fax: 206-575-4439 Email: Fire Marshaltukwilawa. ov Business Name: Type of Inspection: Location Address: - `r � C ei � ; Date : /' 67., Contact er 4k ak►S Phone No. 25-25I`Up/no ACTION REQUIRED ADD ser6t /1 ICCE-12CWIUtr,it— TC) P/tie2-4•`-5 �s�z� �� Prf2-7-4151-&-- ar--Pie-e-s fi•I w� r k ,K \\1/ c6til-td 7ft7-- ir,,/ sk,L7 ( ckw ccek - ,., ,i1/4/ ,,,, ,,, , 424) it/241. CORRECTION OF THE ABOVE ITEMS ARE REQUIRED BY : FAILURE TO COMPLY MAY RESULT IN THE ISSUANCE OF A C INAL CITATION/TICKET. Signature: Billing/Mailing Address : Attn: Company Name: Address: City: State: Zip: ❑ A $100.00 Reinspection Fee is required. You will receive an invoice from the City of Tukwila Finance Department. ❑ Ticket Issued. Citation # Correction Notice Rcinsi, Fee2.doc Revised 6/17/14 T.F.D. Form F.P. 100 06/03/2010 THU 10:43 FAX 2538261033 Fire Sprinklers Inc. irrrrrrirn Fire Sprinklers WA CLIWIRESI°988RJ 001/001 E 1524 45th Street East, Suite 102, Sumner, WA 98390.253-826-0099 • Fax 253-826-1033 • firesprinklersinc c@comcast.net June 3, 2010 Tukwila Fire Department 444 Andover Park East Tukwila, WA 98188 (206) 575-4404 Fax (206) 575-4439 Al, I am requesting a shutdown number to remove (7) 2 %z" hose stations at Leavitt Machinery. The site address is 17300 West Valley Highway. FSI is currently working on the shop drawings for the project and will be getting submittal plans to your office in a couple of days. Other work in the building will include replacement of existing sprinklers and repair of one missing hanger. If you have any questions or need additional information, please don't hesitate to contact me. Sincerely, Jim Stewart !tMWitA FIRE DrkflIgnOiliiii Please call: 575.4402 and give this job No. /0-sOg7 and exact address for she* .inwn or restoratien IIpprovl 17300 W VALLEY HWY 10-S-097 PRODUCT LEGEND 1 INLET NIPPLE (1" MPT) 2 NUT 3 ISOLATION RING 4 COLLAR / WELD FiTTING 5 STAINLESS STEEL FLEXIBLE BRNDED HOSE (,1" NOMINAL DIAMETER) 1.080 (LENGTHS AVAILABLE 31", 36' 48', 60', & 721 6 COLLAR / WELD FITTING 7 NUT 8 REDUCING OUTLET (AVAILABLE 1/2" OR 3/4" FMPT) 9 CENTER BRACKET ASSEMBLY 10 SQUARE BAR (AVAILABLE IN 24' AND 48' LENGTHS) 11 END BRACKET ASSEMBLY 12 SHEEf'METAL SCREW 13 VIC MECHANICAL -T OUTLET STYLE 922 F1RELOCK (1" FMPT) SEE VICTAULIC SUBMITTAL NUMBER 10.85 SEE SUBMITTAL 10.85 FOR MAXIMUM TOTAL BENDS CEILING COVER PLATE SPRINKLER HEAD BRAIDED VICFLEX FLEXIBLE HOSE SPRINKLER ASSEMBLIES FOR STANDARD PENDENT SPRINKLERS P ,f Without Comments 0 As Noted in Red O Per The Attached Letter These plans have been reviewed by The Tukwila .Fire Prevention Bureau for conformance with current City standards. Acceptance is subject to errors and omissions which do not authorize violatIons of adopted standards and ordinances, The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to thesedrawings after this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: 3 l " () By: TUKWILA, FIRS DEPARTMENT Please cal 206-575-4407 and give this Fire Permit No, )-S- and -S-and exact address for shut- down or restoration approval. 4. Concrete /e Construction VIM -EX CONNECTION it e'.0 1 rXISTING - D,'ANC[I UNE NL'W PENDENT HEAD ......................................:.:.: 54.15PEND>:D CEILING 4 'Q A' 4 4 Concrete Construction VIC 1- X CONNECTION ,XI.'T/NS - OPANCH UNe Nr=W PENDENT HEAD \5U5Pi 'NDDD CEILING VICFLEX CONFIG. Deck 1 2"MAX. Upright Pipe TYPICAL EXISTING UPRIGHT HEAD DETAIL IN NON-OBSTRUCTED CONSTRUCTION Wood Joist - NOTE: Wood Anchor Attachments to be drilled into Top Chord of Wood Joist (if applicable) Wood SammyScrew (Horizontal) Wood SammyScrew (Vertical) All Thread -- Rod Swivel Ring Pipe AllRod Ring HANGER DETAILS WOOD ANCHOR ATTACHMENTS 1 N 1 Cross Section WOOD DECK EXISTING 1i" BRANCLINE KNEW PENDENT CEILING FLOOR SCALE: 1/4" = 1'-0" Fi <LE� SCALE:1/4" = 1'-0" LA\�0 *----is-et-+sai[-ra - w ---fir• w WA�SHINt3TON .TATE CEIRTIIFICA' E OF COM PCTEhiCY a- nine PROTECTION SPRIT 1KI.ER Y. TE la;• Jeffrey David Johnson *7815-101 5-0 Na thwost biro S • NORTH it gxplme *41117, 1 r a SCOPE SCOPE OF WORK: - ADD TWO PENDENT SPRINKLERS FOR TWO NEW MOBILE OFFICES - SPRINKLER SYSTEM DESIGN PER N.F.P.A. #13 2013 - EXISTING SYSTEM HYDRAULICS ARE NOT EFFECTED BY ADDED SPRINKLERS LIGHT HAZARD OCCUPANCY GENERAL NOTES 1) DESIGN PER N.F.P.A. #13 - 2013 AND LOCAL STANDARDS ALL MATERIALS SHALL BE NEW AND U.L. LISTED OR F.M. APPROVED 2) ALL HANGERS AND SWAY BRACING TO BE BY N.F.P.A. STANDARDS 3) SYSTEM SHALL BE INSTALLED, BRACED AND TESTED IN ACCORDANCE WITH N.F.P.A. #13 - 2013 4) ALL PAINTING OF FIRE SPRINKLER PIPING (IF REQ.) TO BE DONE BY OTHERS. 5) OWNER IS RESPONSIBLE TO ASSURE THAT STRUCTURE AS IT IS SHOWN ON CONTRACT DRAWINGS CAN ADEQUATELY SUPPORT ALL FIRE SPRINKLER PIPING LOADS. NO AUXILLIARY DEVICES OR ATTACHMENTS SHALL BE PROVIDED BY NORTHWEST FIRE SYSTEMS PROTECTION TO SUPPUMENT THE STRUCTURE TO ACCOMODATE FIRE SPRINKLER PIPING LOADS. 6) OWNER IS RESPONSIBLE TO PROVIDE ADEQUATE HEAT TO MAINTAIN 40 DEG. F. MINIMUM AT ALL TIMES YEAR ROUND. IN ALL AREAS WITH WATER FILLED FIRE SPRINKLER PIPING. INSULATION INSTALLED TO MAINTAIN THIS TEMPERATURE (SUCH AS ATTICS, CEILINGS AND AT WALLS) SHALL BE LOCATED ON THE COLD SIDE OF THE PIPE ONLY WITH NO INSULATION ON THE WARM SIDE OF THE PIPE FACING THE HEATED INTERIOR. 7) FIRE ALARM SYSTEM DEVICES, INSTALLATION OR MONITORING IS NOT INCLUDED IN THIS CONTRACT (DONE BY OTHERS) 8) NORTHWEST FIRE SYSTEMS ASSUMES NO RESPONSIBILITY , EITHER EXPRESSED OR IMPLIED, FOR THE CONDITION, PERFORMANCE OR CURRENT CODE COMPLIANCE OF ANY OTHER WATER OR FIRE PROTECTION SYSTEM(S) ON SITE EXCEPT FOR WORK PERFORMED DIRECTLY BY NORTHWEST FIRE SYSTEMS UNDER THE SPECIFIC SCOPE OF OF THIS CONTRACT. 9) ALL PIPING WITH THREADS TO BE SCHEDULE 40 BLK. STL PIPE WITH C.I. OR D.I. SCREWED FITTINGS 10) LIGHT HAZARD OCCUPANCY - OFFICES. (SPRINKLERS SPACED AT 225 SQ.FT. MAX.) 11) SPRINKLER PIPE PENETRATIONS THROUGH SUSPENDED CEILINGS SHALL MEET THE REQUIREMENTS OF ASCE 7-05 SECTION 13.5.6.2.2.. PENETRATIONS TO HAVE A 2 INCH OVERSIZE RING OR ADAPTER THROUGH THE CEILING TO ALLOW FOR FREE MOVEMENT OF AT LEAST 1" IN ALL HORIZONTAL DIRECTIONS. SPRINKLER ATTACHED OR BRACED TO CEILING (SUCH AS SPRINKLERS AND CEILINGS ATTACHED TO THE SAME JOIST) DO NOT REQUIRE THIS ALLOWANCE FOR MOVEMENT 12) OWNER IS RESPONSIBLE TO ARRANGE FOR THE PERIODIC INSPECTION, TESTING AND MAINTENANCE OF THESE FIRE SPRINKLER SYSTEMS IN ACCORDANCEWITH THE MINIMUM REQUIREMENTS OF N.F.P.A. 25-2013 BY QUALIFIED PERSONNEL COMMENCING AFTER WARRANTY PERIOD HAS EXPIRED. THE FIRM THAT DESIGNED AND INSTALLED THIS SYSTEM IS BEST QUALIFIED TO PROVIDE THE ONGOING LONG TERM TESTING, MAINTENANCE AND SERVICING OF THIS SYSTEM. EXCLUSIONS: 1) OVERTIME WORK 2) FIRE EXTINGUISHERS OR ALARM DETECTION 3) CENTER OF TILE 4) DRAIN FEES &TIE-IN FEES 5) PREP FOR OR PAINTING OF PIPE 6) DEMOLITION 7) RELOCATION OF MAINS OR BRANCHLINES 8) FIRE CAULKING 9) ANY EXISTING DEFICIENCIES 10) ACCESS PANELS 11) WIRING, (FIRE ALARM) MONITORING OF VALVES, SUPERVISORY AND WATERFLOW SWITCHES, ETC... FIELD / LISTING NOTES 1) THREADED PIPE FROM 1" THRU 2" SIZE TO BE'SCHED.40' 2) ALL THREADED FITTINGS ARE TO BE 175# CAST IRON (IMP./DOM.) 3) ALL 1" NIPPLES NOT IDENTIFIED ARE 0-4 U.N.O. 4) ALL HANGER RODS TO BE FIELD CUT 5) ALL PIPE LENGTHS SHOWN ARE CUT LENGTH DIMENSIONS. INTERNAL DIAMETERS - STEEL PIPE PIPE SIZE SCHEDULE 4C SC HEDULE 1C DYNA THREACDYNA FLOW EZ -FLOW 1" 1.049 0 1.097 12-0 1.080 15-0 1.191 15-0 15-0 15-0 1 1/4" 1.380 1.442 1.408 ,1 .536 1 1/2" 1.610 1.682 1.639 1.728 2" 2.067 2.157 2.104 ' 2.203 2 1/2" 2.469 2.635 2.703 3" 3.068 3.260 3.314 3 1/2" 3.548 3.760 4" 4.026 4.260 4.310 4.316 5" 5.047 5.295 6" 6.065 6.357 6.385 8" 8.071 8.249 10" 10.140 10.370 SPRINKLER COMPONENT LEGEND = NEW FIRE SPRINKLER PIPING - - - - = EXISTING FIRE SPRINKLER PIPING = NEW TYCO QR SEMI-REC. PENDENT ;; = EXISTING UPRIGHT n= NEW 1" VICFLEX A = ADDED HEADS (2 TOTAL) M.T.X = NEW MECHANICAL TEE = NOT IN CONTRACT NFPA 13 (2013) - TABLE 9.2.2.1(a) MAX. DISTANCE BETWEEN HANGERS KEY PLAN Pro'ect Location IMPORTANT: IN LOCATIONS SUBJECT TO FREEZING CONDITIONS, IT IS THE OWNERS RESPONSIBILITY TO PROVIDE HEAT THROUGHOUT WET PIPE SPRINKLER SYSTEM AREAS AND IN ENCLOSURES FOR DRY PIPE AND OTHER TYPES OF VALVES CONTROLLING WATER SUPPLIES TO SPRINKLER SYSTEMS. ALL SPRINKLER HEAD AND HANGER LOCATIONS ARE SUBJECT TO CHANGE DUE TO FIELD CONDITIONS TO MEET NFPA#13. HEAD LOCATIONS ARE NOT CENTER OF TILE UNLESS NOTED OTHERWISE. THESE DRAWINGS ARE THE PROPERTY & COPYRIGHT OF NORTHWEST FIRE SYSTEMS. ALL RIGHTS ARE RESERVED. ALL NOTATIONS, DESIGN, AND INFORMATION CONTAINED HEREIN SHALL NOT BE USED BY ANY OTHER ENTITY FOR ANY OTHER WORK, PROJECT, OR CONTRACT. ALL WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALED DIMENSIONS AND ALL SHOULD BE VERIFIED ON SITE PRIOR TO INSTALLATION. -0 k O BOD BOB BOJ FOS FOW GENERAL LEGEND EARTHQUAKE BRACING PIPE HANGER GROOVED CAP RIGID COUPLING ( UNLESS NOTED ) CAP PLUG CENTERLINE HYDRAULIC REFERENCE POINT CENTERLINE PIPE TO BOTTOM OF DECK CENTERLINE PIPE TO BOTTOM OF BEAM CENTERLINE PIPE TO BOTTOM OF JOIST FACE OF STUD FACE OF WALL FOC AFF CH R.C. E/C C/C C/E GG TG TxF ATR FACE OF CONCRETE ABOVE FINISHED FLOOR CEILING HEIGHT REDUCING COUPLING OUTLET COUPLING WELDED OUTLET 'Fi" F1TiING END TO CENTER CENTER TO CENTER CENTER TO END GROOVE/GROOVE THREAD/GROOVE (ALSO "GT") THREADpFlT" (ALSO 'Fxr) ALL -THREAD ROD REV 0 DATE BY DESCRIPTION SPRINKLER LEGEND SYMBOL ORIF. TEMP. FINISH K= DESCRIPTION SIN# ESC. FINISH QTY NEW HEADS A 1/2" 155'F CHR. 5.6 NEW TYCO MODEL TY -FRB, QR SEMI-REC. PENDENT TY3231 S. -R. CHR. 2 0 0 LICENSE #NORTHFS928CR Leavitt Machinery WITHWEST FIRE SYSTEMS Saving Laves, Protecting Pr.aperty, 0 TOTAL NEW SPRINKLERS FOR FLOOR:2 TOTAL NEW SPRINKLERS FOR PROJECT: 2 22645 83rd Ave. S, Bldg. D, Kent, WA 98032 Office: (206) 772-7502 Fax: (206) 772-750' 17300 W VALLEY HWY WWW.NWFIRESYSTEMS.CON 17-S-159 17300 W Valley Hwy Tukwilla, WA 9891\ A'tj1.32017 1UKwtLAMITE e.2e21) Date: 8/15/17 Drawn By: TH checked By: JJ Scale:as noted NJ Job #.O+ 1oC' FP1 of 1 1" 14" 1 2" 2" 22" 3" 4" 6" STEEL PIPE EXCEPT THREADED LIGHTWALL 12-0 12-0 15-0 15-0 15-0 15-0 15-0 15-0 KEY PLAN Pro'ect Location IMPORTANT: IN LOCATIONS SUBJECT TO FREEZING CONDITIONS, IT IS THE OWNERS RESPONSIBILITY TO PROVIDE HEAT THROUGHOUT WET PIPE SPRINKLER SYSTEM AREAS AND IN ENCLOSURES FOR DRY PIPE AND OTHER TYPES OF VALVES CONTROLLING WATER SUPPLIES TO SPRINKLER SYSTEMS. ALL SPRINKLER HEAD AND HANGER LOCATIONS ARE SUBJECT TO CHANGE DUE TO FIELD CONDITIONS TO MEET NFPA#13. HEAD LOCATIONS ARE NOT CENTER OF TILE UNLESS NOTED OTHERWISE. THESE DRAWINGS ARE THE PROPERTY & COPYRIGHT OF NORTHWEST FIRE SYSTEMS. ALL RIGHTS ARE RESERVED. ALL NOTATIONS, DESIGN, AND INFORMATION CONTAINED HEREIN SHALL NOT BE USED BY ANY OTHER ENTITY FOR ANY OTHER WORK, PROJECT, OR CONTRACT. ALL WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALED DIMENSIONS AND ALL SHOULD BE VERIFIED ON SITE PRIOR TO INSTALLATION. -0 k O BOD BOB BOJ FOS FOW GENERAL LEGEND EARTHQUAKE BRACING PIPE HANGER GROOVED CAP RIGID COUPLING ( UNLESS NOTED ) CAP PLUG CENTERLINE HYDRAULIC REFERENCE POINT CENTERLINE PIPE TO BOTTOM OF DECK CENTERLINE PIPE TO BOTTOM OF BEAM CENTERLINE PIPE TO BOTTOM OF JOIST FACE OF STUD FACE OF WALL FOC AFF CH R.C. E/C C/C C/E GG TG TxF ATR FACE OF CONCRETE ABOVE FINISHED FLOOR CEILING HEIGHT REDUCING COUPLING OUTLET COUPLING WELDED OUTLET 'Fi" F1TiING END TO CENTER CENTER TO CENTER CENTER TO END GROOVE/GROOVE THREAD/GROOVE (ALSO "GT") THREADpFlT" (ALSO 'Fxr) ALL -THREAD ROD REV 0 DATE BY DESCRIPTION SPRINKLER LEGEND SYMBOL ORIF. TEMP. FINISH K= DESCRIPTION SIN# ESC. FINISH QTY NEW HEADS A 1/2" 155'F CHR. 5.6 NEW TYCO MODEL TY -FRB, QR SEMI-REC. PENDENT TY3231 S. -R. CHR. 2 0 0 LICENSE #NORTHFS928CR Leavitt Machinery WITHWEST FIRE SYSTEMS Saving Laves, Protecting Pr.aperty, 0 TOTAL NEW SPRINKLERS FOR FLOOR:2 TOTAL NEW SPRINKLERS FOR PROJECT: 2 22645 83rd Ave. S, Bldg. D, Kent, WA 98032 Office: (206) 772-7502 Fax: (206) 772-750' 17300 W VALLEY HWY WWW.NWFIRESYSTEMS.CON 17-S-159 17300 W Valley Hwy Tukwilla, WA 9891\ A'tj1.32017 1UKwtLAMITE e.2e21) Date: 8/15/17 Drawn By: TH checked By: JJ Scale:as noted NJ Job #.O+ 1oC' FP1 of 1 .t -c i -+ al LQ \ eW 1'1-4k 5.124) fUKWILA FIRE DEPARTMENT 5 Please call: 575-4407 and give this job No. '105 31)1 and exact address for shuts down or restoration approval z w J MANUAL PULL STATION WATERFLOW DETECTOR POST INDICATOR VALVE WITHOUT COMME',iTS. )g". AS NOTED IN RE ) Q PER THE ATTAC. ;ED LETTER The drawings affixed hereto have been reviewed and accepted by the City of Tukwila Fire Dept. Additions, del ' ms or revisions to these "lags aii: 'is date will void this a. ;: ,no. an :11 require a resubmittal of revise f wings. Final acceptance is subject to fir 11 - inspection by a representative of t,�is department DATE: al,g, _ BY .A , 5( CITY OF TUKWILA 575-4407 1— cn Q US INK CORPORATION O Z 0 SPRINKLER 1 � h h ACCEPTED Without Comments As Noted In Red Per The Attached Letter These plans have been reviewed by The Tukw Prevention Bureau for conformance with curre standards. Acceptance is subject to errors an omissions which do not authorize violations of standards and ordinances. The responsibility f adequacy of design rests totally with the desig Additions, deletions or revisions to these drawl this date will void thie,acceptance and will requ resubmittal of revised drawings for subsequent 1 Fire t city dopted r the s after ea pproval. Sinai acceptance is suL;ect to field test and in ; -ction by The Tukwila Fire Prevention Bureau. Date: '5 - 1 ` D By: AIM( NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing. STORAGE OFFICE fUKWftA FIRE DEPAR i IAtl iI; Please call: 575.4402 and give this job No. bF- 053 and exact address for shut. down or restoration approval. /73a GLS/ 17300 W VALLEY HWY 06-F-053 ' WASHINGTON ALARM, INC. 1253 S. JACKSON STREET SEATTLE, WASHINGTON 98144 PHONE 206-328-3288 FAX: 206-322-7214 CONTACT: Matt Kellogg WWW. WASHINGTONALARM.COM v LUNCHROOM CONF. ROOM OFFICE STORAGE OFFICE LOCKER ROOM BATH 11034 BATH ROOM OFFICE FURNACE ROOM OFFICE TO FIRST FLOOR OFFICE r_ OFFICE w ct 0 V) WA9 JNGTON ALARM, INC. 1253 S. JACKSON STREET SEATTLE, WASHINGTON 98144 PHONE 208-328-3285 FAX: 205-322-7214 CONTACT: Matt Kellogg WWW. WASHINGTONALARM.COM 0 U (1) 124 >. coQ O c" .Td O x coo Td � >, LL 0 C cC G1 Z 75 L ZA ;3 u co (I) M-=‘ P-4 (/) Wire Legend Type DESCRIPTION A 18 AWG, 2 CONDUCTOR 'FPLP' JACKETED CABLE1 B 14 AWG, 2 CONDUCTOR 'FPLP' JACKETED CABLE1 C 18 AWG, 4 CONDUCTOR 'FPLP' JACKETED CABLE1 GENERAL NOTES: 1. ALL WORK IS TO CONFORM TO NATIONAL ELECTRIC CODE STANDARDS. 2. WIRING METHOD IS TO BE OPEN CABLING EXCEPT WHERE IT IS EXPOSED AND BELOW SEVEN FEET—THEN IT IS TO BE IN CONDUIT. 3. ALL JUNCTION BOXES, COVERS AND BACK BOXES ARE TO BE PAINTED RED. 4. PULL STATIONS ARE TO BE MOUNTS AT 48" TO 53" ABOVE THE FLOOR. 5. ALL INDOOR HORNS, STROBES, HORN STROBES AND MINI HORN STROBES ARE TO BE MOUNTED 80" ABOVE THE FLOOR OR 6" BELOW THE CEIUNG, WHICHEVER IS LOWER. 6. SMOKE DETECTORS SHALL BE INSTALLED IN ACCORDANCE WITH THE FOLLOWING: A) 36" AWAY FROM ANY AIR HANDLING SYSTEM DIFFUSER B) NOT IN CLOSE PROXIMITY TO ANY FLUORESCENT UGHT_FIXTURES 7. EXTERIOR HORN/STROBE SHALL BE MOUNTED ON THE TOP % OF THE OUTSIDE WALL OF THE BUILDING, AS HIGH AS POSSIBLE FOR MAXIMUM VISIBILITY FROM THE FIRE DEPARTMENT ACCESS ROADWAY. 8. ALL WIRING PENETRATING ANY FIRE RATED BARRIER SHALL BE SEALED WITH MATERIAL WHICH WILL PREVENT PASSAGE OF FLAME AND HOT GASSES. 9. SPACE HAS DROPPED CEIUNG AT 10'0". HALF WALLS EXTEND TO 8'6". Symbol Legend FACP FIRE ALARM CONTROL PANEL (Th GONG OR BELL/STROBE OR BELL J L Ell HORN/STROBE FAAP ANNUNCATOR PANEL TAMPER SWITCH SPRINKLER FLOW SWITCH HEAT DETECTOR OSMOKE DETECTOR MANUAL PULL FAAP 4t AZ> FACP EOL J L EB. EOL EOL EOL WASHINGTON ALARM, INC. 1253 S. JACKSON STREET SEATTLE, WASHINGTON 98144 PHONE 206-328-3288 FAX: 208-322-7214 CONTACT: Mott Kellogg W W W. WASH I N GTONALARM. C OM Pacific NW Sales & Recovery { OEOL FIRE ALARM PLAN 11 O' I/8" = r -O" EXIST. BUILDING 18awg. 2 conductor 1 14awg. 4 conductor FROM EXIST. FACP ZONE #2 ZONE #1 NEW BULDNG EXIST. BULDNG WEST VALLEY ROAD SITE PLAN NITS. SPRINK. SUPERVISION - WATERFLOW ACCEPTED WITHOUT COMMENTS. ❑ AS NOTED IN RED ❑ PER THE ATTACHED LETTER The drawings affixed hereto have been reviewed and accepted by the City of Tukwila Fire Dept. Additions, deletions or revisions to these drawings after this date will void this acceat:ance and will require a resubmittal of revised drawings. Final -acceptance is subject to field - inspection by a representative of this department DATE 7/1 __,BY: CZ I CITY OF TUKWILA 575-4407 -00000 FAcfJ HORN CIRCUIT RISER DIAGRAM YM LEND SYME)OL. DESCRIPTION Fire Adam Control Panel Manual Puktation 135'Rate Of Rise/Fixed Temp. Heat Detector Fire Alarm Horn/`,trobe TUKWILA FIRE DEPARTMENT Please call: 575-4407 and give this job No.—/r zyo and exact address for shut- down or restoration approval. f emit /O+W91 ,Tc'C eJrrt''` —e T s/`'t� I/ - c,72d't.. CnrvT4-cT 5 7, „ /'#V7 l &At/ FILE ProjecL Nome: U.S. PRINTING 17300 WEST VALLEY HWY. TUKWILLA, WA. °Di 9/24/939Y'' Type: AUTOMATIC FIRE ALARM J.F.�''°""'�' Scethir AS SHOWN Legit s CUSTOH1254-PT Date Revtstan Det Re:ton �. -- P.O. BOX 3407 ,.IA o a>cAz - 1 -� � i i r--1 / iii , . k . ; „�.Ic.. SECURITY SYSTEMS Tea 17300 W VALLEY HWY At - AAL O Ar+1 Y 1-0 FT EXISTI\G \D cud EXISTIN G FOCUS 200 CONTR�L [JANE_ sc f TO CENTRAL STAT ION 1 CONN bLc _ k MP tANUAL ULL STATION CH) HEAT DETECTCR 120 V'A C APPROVED DATE PROJECT NAME DRAFTSMAN CRUSON SCALE! NONE OSWALT 841 POWELL AVE SW RENTON, WA 98055 (206) 624-3103 FAX= 654-2189 US INK CORPORATION SHEET TITLE SECURITY SYSTEMS FIRE ALAR ;i AC DI A EXISTING DEVICE2 REVISICr,IS UO. TA t>_ DESC F?IP"}i N .,.E VOW Ian r m f