HomeMy WebLinkAboutPP - 12516 50TH PL S - CARY LANG CONSTRUCTION / ALLENTOWN LOT 74 - PERMITS AND PLANS12516 50TH PL S
ASSOCIATED PERMITS
17-S-108
D17-0038
SITE LOCATION
CITY OF TUKWILA
FIRE MARSHAL'S OFFICE
206-575-4407
FIRE PROTECTION SYSTEMS PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
**PLEASE PRINT**
King Co. Assessor's Tax No.: 0179002655
Site Address: 12 516 50th PL S Tukwila, WA Suite Number: Floor:
Tenant Name: CARY LANG CONSTRUCTION INC 759999
Property Owner's Name: CARY LANG CONSTRUCTION INC 759999
Mailing Address: 29815 2 4TH AVE SW
New Tenant? ❑x - Yes ❑ - No
FEDERAL WAY WA 98023
City State " Zip
CONTACT PERSON -if there are questions about the submittal.
Name: DANIEL RADLOFF Day Telephone: 253-840-9900
Company Name: RED HAWK FIRE PROTECTION LLC .
Mailing Address: 801 VALLEY AVE NW SUITE D PUYALLUP WA 98371
DANIELR@REDHAWKFP . COM City State Zip
E-mail Address: Fax Number:
NICET III number: REDHAHF 9 0 ja
Contractor's City of Tukwila BUS —0997549
Business License number:
Total number of new/relocated devices or sprinkler heads: 26 NEW SPRINKLER HEADS
Valuation of Project (contractor's bid price): $ 6800
Scope of Work (please provide detailed information): Installation of an Automatic Fire Sprinkler
System in a new single family residence, 26 heads, flow through design
PERMIT APPLICATION NOTES
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be
reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules.
Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit
is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or
abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in
writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing
and justifiable cause demonstrated.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE
UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY
FOR THIS PERMIT.
BUILDING OWNER ORAUTHORIZED AGENT:
Signature: Jok^�c i Date: f jOSII`7
Print Name: Dake e I f Day Telephone: (}'S J 1840 r'ioo
Plan Permit App.doc 8/22/14 TFD FP Form 8
INSPECTION NUMBER
INSPECTION RECORD
Retain a copy with permit
--a 3t
PERMIT NUMBERS
CITY OF TUKWILA FIRE DEPARTMENT
206-575-4407
Project:
Sprinklers:
Type of In ctio
Address: ,
Suite #: /1--4
Ca /9Z
Contact er on:
Special Instructions:
Occupancy Type:
Phone No.:
KApproved per applicable codes.
Corrections required prior to approval.
COMMENTS:
/4$1re
tqlgren
Mo .mss ov Cd-‘ h) /A/Fee-/)
Needs Shift Inspection:
Sprinklers:
Fire Alarm:
Hood & Duct:
Monitor:
Pre -Fire:
Permits:
Occupancy Type:
Inspector: MO
Date: 9/J/`7
Hrs.: Z. 0
$100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from
the City of Tukwila Finance Department. Call to schedule a reinspection.
Billing Address
Attn:
Company Name:
Address:
City:
State:
Zip::
Word/Inspection Record Form.Doc
3/14/14
T.F,D. Form F.P. 113
INSPECTION NUMBER
INSPECTION RECORD
Retain a copy with permit
X11- OO��
PERMIT NUMBERS
CITY OF TUKWILA FIRE DEPARTMENT
206-575-4407
Project:
wit,
Fire Alarm:
Type of Inspection:
142C—
Address: / 2 5 Ile
Suite #: / 24
-Z;IT'' 102_
S ,
Contact Person:
Special Instructions:
Phone No.:
Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
Needs Shift Inspection:
Sprinklers:
Fire Alarm:
Hood & Duct:
Monitor:
Pre -Fire:
Permits:
Occupancy Type:
Inspectofr,
„i
sr-3
Date: '77/ T// -7
Hrs.:
/-
6
/
$100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from
the City of Tukwila Finance Department. Call to schedule a reinspection.
Billing Address
Attn:
Company Name:
Address:
City:
State:
Zip:
Word/Inspection Record Form.Doc
3/14/14
T.F.D. Form F.P. 113
50TH PL. S.
CITY CONNECTION
1" TAP BY
OTHERS
PORTCH
•r
N
POWDER
SYMBOLS
SCOPE OF WORK
NEW 1"
WATER
METER
BY OTHERS
ENTRY
11/2" CPVC UG BY
OTHERS
NEW 6" ELECT.
ALARM BELL
5/8" TYPE "X" GWB (TYP.)
ATTIC SPACE
BEDROOM 2
MASTER BATH
9
7
GREAT ROOM
PATIO
x
SECTION
SCALE: NONE
/
co
r � r
X•XAFF
HYDRAULIC NODE
ELECTRIC BELL
EXISTING SPRINKLER PIPING
NEW SPRINKLER PIPING
CENTERLINE OF PIPE ABOVE FINISHED
FLOOR
RED HAWK FIRE PROTECTION, LLC (RHFP) WILL PROVIDE ONE WET PIPE AUTOMATIC
SPRINKLER SYSTEM TO PROTECT THE RESIDENCE.
RHFP WILL START WORK AT 11/2" UNDERGROUND SUPPLY LOCATED IN GARAGE.
ALL AREAS PROTECTED BY A WET SYSTEM MUST BE MAINTAINED BY OTHERS AT A
MINIMUM 40°F TO PREVENT FREEZING.
EXCLUSIONS
PAINTING OR LABELING OF PIPE AND/OR EQUIPMENT
ELECTRICAL WIRING OF ANY KIND INCLUDING BUT NOT LIMITED TO WATERFLOW
SWITCH, ELECTRIC BELL, AND TAMPER SWITCHES
CENTRAL STATION MONITORING EQUIPMENT, WIRING AND SERVICES
RED HAWK SCOPE OF WORK TO EXCLUDE ALL UNDERGROUND WORK OF ANY
KIND.
CEILING AND WALL REMOVAL/REPLACE TO FACILITATE THE INSTALLATION OF THE
SPRINKLER SYSTEM.
GENERAL NOTES
DESIGN CRITERIA
1. SPRINKLER SYSTEM DESIGN PER NFPA#13D 2013.
2. ALL MATERIALS SHALL BE NEW AND UL AND/OR FM APPROVED.
3. FIRE SPRINKLER SYSTEM TO BE INSTALLED, BRACED AND TESTED IN
ACCORDANCE WITH NFPA#13D (2010) AND SPECIFICATIONS.
4. IN LOCALITIES SUBJECT TO FREEZING CONDITIONS IT IS THE OWNERS
RESPONSIBILITY TO PROVIDE HEAT THROUGH OUT THE WET PIPE SPRINKLER
SYSTEM AREAS AND IN ENCLOSURES FOR DRY PIPE, DELUGE AND OTHER
TYPES OF VALVES CONTROLLING WATER SUPPLIES TO SPRINKLER SYSTEMS.
5. FIRE PROTECTION CONTRACTOR SHALL NOT BE RESPONSIBLE FOR THE
ABILITY OF THE STRUCTURE TO ADEQUATELY SUPPORT THE FIRE SPRINKLER
SYSTEM OR ANY APPURTENANCES THEREOF.
6. ALL ELECTRICAL, PAINTING OF PIPE, FURRING, CUTTING OR PATCHING TO BE
BY OTHERS.
7. ALL PIPING IN RESIDENTIAL UNITS TO BE CPVC PIPE.
8. ALL THREADED PIPE TO BE SCHEDULE 40 BLACK JOINED WITH CAST IRON
THREADED FITTINGS.
9. ALL WELDED PIPE TO BE SCHEDULE 10 BLACK JOINED WITH GROOVED
FITTINGS.
10. ALL GROOVED COUPLINGS TO BE RIGID UNLESS NOTED OTHERWISE.
11. SEE FP 1.10 FOR SYSTEM STANDARD DETAILS.
12. ALL HANGERS FOR CPVC ARE TO BE PER DETAILS ON SHEET FP 1.10 (UNO).
13, ALL HANGERS FOR STEEL PIPE TO BE NO. 15W SAMMY SIDEWINDER (UNO).
14. ALL PIPE DIMENSIONS ARE CUT LENGTHS (UNO)
Without t.. ocr,c t .:r
AS M , .t
der�iheotetAtfi ;h.e.i,E.mer
These pians Nave been reviewed by The Tukwila Fire
^re"ention Pureau for conformance with current City
rr : , dards. Acceptance is subject to errors and
r,lsslor,s which do not authorize violations of adopted
s';andards and ordinance_:. The responsibility for the
:,,fl quacy of design rests tlItekry ak/Ith the designer.
Additions, deletions ro!" revisions to these drawings after
this date will void this ato ptance and will require a
resubmittal of revised di rings'for stib inert approval.
Final acceptance is subject to field test and inspection by
The Tukwila Fire Prevention Bur
eau,
Date: -1 ? By:3
bfya o retviva•
4 now (6,0(1.4)4,44-: rev,.
PER NEPA 13D (2013), CITY OF TUKWILA.
RM -01 (RESIDENTIAL)
WET SYSTEM
RESIDENTIAL
DESIGN DENSITY: 0.05 GPM / MOST DEMANDING 2 HEAD FLOW
18'-0" X 18'-0" MAX SPACING
17.17 GPM/SPRINKLER PER MANUFACTURER
FLOW TEST INFORMATION
:F',V ,GER FLOW HAS BEEN RESTRICTED WITH PRESSURE REDUCING VALVE BY
OTF:F9S A MINIMUM OF 60 PSI. SHALL BE MAINTAINED.
CALCULATIONS MADE AT:
STATIC PRESSURE: 60 PSI RESIDUAL PRESSURE 20 PSI
RESIDUAL FLOW: 1200 GPM
ACTUAL SITE PRESSURE AS PER MIKE CUSICK OF TUKWILA WATER:
STAT'C PRESSURE: 120 PSI RESIDUAL PRESSURE 20 PSI
RESIDUAL FLOW: 4910 GPM
DRAWING INDEX
RED HAWK
FIRE PROTECTION, LLC
Eifree
801 VALLEY AVE NW, SUITE D
PUYALLUP, WA 98371
PHONE: (253) 840-9900 FAx (800) 591-4382
WA CL# REDHAHF9010P
FP 0.10 SITE PLAN AND NOTES
FP 2.10 FIRE SPRINKLER PLAN
NICET Stamp
Approvals Required
TUKWILA FIRE MARSHAL
OWNER /ARCHITECT
Revisions
Contract With:
CARY LANG.
CONSTRUCTION
29815 24th AVE SW
FEDERAL WAY, WA 98023
CONTACT: CARY LANG
Phone: 253-661-6880
Fax:
Contract Name:
ALLENTOWN 74
12516 50TH ST SO. TUCKWILA WA
98178
PARCELL # 0179002655
Drawing Title
SITE PLAN AND NOTES
VICINITY MAP
Key Plan
a.
TUKWILA FIRE DEPARTMENT
Please call 206-675-4407 and
giva t: l:Fire, Perrriit No.
and c-axact address for shut-
down or restorclion approval.
Green R,vcr l •aid
Adecco stc:°(jng
ar Seattle
Date:
Job Number:
Designer:
Building Permit:.
Drawing No.
Green River l-taa
Gateway
Corporate Center
...Cai�.
12516 50 PL S
17-S-108
June 09, 20.17
80079
BEN BERNARD
FPO.1.O
PAID
JUP i
4.t: 7' •
1
36" MIN.
DIST.
FROM
HEAT
SOURCE.
OPEN TC ABC'}
•
11
J
O
<y.
0
O
0
0
SGO
TOIL
.L7/1
MAIN FLOOR FIRE SPRINKLER PLAN
2 4
SCALE 1/4"=l'-0"
HANGER NO. 513
HANGER TYPE U
NTS
FIG.12C
/ LAG BOLT
WOOD TJI/ROOF TRUSS
HANGER NO. 510
HANGER TYPE W
NTS
HANGERS - PIPE HANGERS SHALL BE SIZED, SPACED AND INSTALLED AS REQUIRED
BY NFPA STANDARDS
- NO OTHER PIPING AND/OR DEVICES ARE TO BE ATTACHED TO THE SPRINKLER PIPE
HANGER SYSTEM UNLESS THE HANGER HAS BEEN SPECIFICALLY DESIGNED FOR
THE ADDITIONAL LOADING.
- THIS CONTRACT DOES NOT INCLUDE ANY MATERIAL OR DEVICES TO IMPROVE THE
STRUCTURAL STRENGTH OF THE BUILDING TO ENABLE IT TO CARRY THE LOAD OF
THE FIRE PROTECTION SYSTEM.
- SEE DETAILS ON THIS SHEET FOR THE SPECIFIC HANGER ASSEMBLIES USED FOR
THIS INSTALLATION.
NFPA 13, 2010 Edition
Table 9.2.2.1 MAXIMUM DISTANCE BETWEEN HANGERS (ft - in)
PIPE TYPE
CPVC
NOTES
1. LOWER CEILINGS TO BE 9-1 AFF. UPPER CEILINGS TO BE 8-1 AFF.
UNLESS NOTED OTHERWISE.
2. PIPE FROM RISER TO UPPER FLOOR TO BE 11/2" CPVC, ALL OTHER
PIPE TO BE.1" CPVC UNLESS NOTED OTHERWISE.
3. SPRINKLERS OMITTED FROM ALL CLOSETS MEETING THE
REQUIREMENTS OF SECTION 8.6.3 OF NFPA 13D (2013) AREAS MARKED
WITH HATCH
4. SPRINKLERS OMITTED FROM ALL BATHROOMS UNDER 55 FTS PER
SECTION 8.6.2 OF NFPA 13D (2013) AREAS MARKED WITH HATCH
5. PRESSURE REDUCING VALVE TO BE SET AT 60 PSI. MIN.
HANGER NO. 511
HANGER TYPE X
NTS
FIG. 126
LAG BOLT
WOOD JOIST OR
COMPOSITE WOOD JOIST
{
UPPER FLOOR FIRE SPRINKLER PLAN`
112"
2
4
SCALE 1/4"=1'-0"
\"NO BLOCK" HANGER
HANGER NO. 514
HANGER TYPE Y
NTS
NOMINAL PIPE SIZE (IN. )
3/4 1 1 1/4 1 1/2 2 2 1/2 3
5-6 6-0 6-6 7-0 8-0 9-0 10-0
MINIMUM DISTANCES FOR ORDINARY- AND
INTERMEDIATE -TEMPERATURE RESIDENTIAL SPRINKLERS
(NFPA 13D-2002 TABLE 7.5.5.3)
HEAT SOURCE
MINIMUM
DISTANCE FROM
EDGE OF SOURCE TO
ORDINARY-
SPRINKLER
(INCHES)
MINIMUM
. DISTANCE FROM
EDGE OF SOURCE TO
INTERMEDIATE -
SPRINKLER
(INCHES)
SIDE OF OPEN OR
RECESSED FIREPLACE
36
12
FRONT OF RECESSED
FIREPLACE
60
36
COAL- OR WOOD-
BURNING STOVE
42
12
KITCHEN RANGE
18
9
WALL OVEN
18
9
HOT AIR FLUES
18
9
UNINSULATED
HEAT DUCTS
UNINSULATED
HOT WATER PIPES
18
12
g
6
SIDE OF CEILING- OR WALL-
MOUNTED HOT AIR DIFFUSERS
24
12
FRONT OF WALL-
MOUNTED HOT AIR DIFFUSERS
36
18
HOT WATER HEATER
OR FURNACE
6
3
LIGHT FIXTURE:
OW -250W
6
3
LIGHT FIXTURE:
250W -499W
12
6
Hydraulic Information
Remote Area 1
OCCUPANCY CLASSIFICATION
Residential 18x18
DENSITY
0.050gpm/ft2 for 900.00ft2 (Actual 252.43ft2)
TOTAL HEADS FLOWING
2
K -FACTOR
4.9
TOTAL WATER REQUIRED
34.34
TOTAL PRESSURE REQUIRED
44.443
BASE of RISER (gpm)
34.34
BASE of RISER (psi)
25.099
SAFETY MARGIN (psi)
+15.501 (25.9%)
HANGERS - PIPE HANGERS SHALL BE SIZED, SPACED AND INSTALLED AS REQUIRED
BY NFPA STANDARDS
- NO OTHER PIPING AND/OR DEVICES ARE TO FE ATTACHED TO THE SPRINKLER PIPE
HANGER SYSTEM UNLESS THE HANGER HAS,3EEN SPECIFICALLY DESIGNED FOR
THE ADDITIONAL LOADING.
- THIS CONTRACT DOES NOT INCLUDE ANY MATERIAL OR DEVICES TO IMPROVE THE
STRUCTURAL STRENGTH OF THE BUILDING TI) ENABLE IT TO CARRY THE LOAD OF
THE FIRE PROTECTION SYSTEM.
- SEE DETAILS ON THIS SHEET FOR THE SPECI;=IC HANGER ASSEMBLIES USED FOR
THIS INSTALLATION.
NFPA 13, 2002 Edition
Table 9.2.2.1 MAXIMUM DISTANCE BETWEEN HANGERS (ft - in)
PIPE TYPE
CPVC
NOMINAL PIPE SIZE ( IN. )
3/4 .1 1 114 1 1/2 2 2 1/2 3 •
5-6 6-0 6-6 7-0 8-0 9-0 10-0
Caution: It is important that the
insulation be installed tight against the
joists. In unheated areas, any spaces
or voids between the insulation and the
joists causes the water in the fire
sprinkler piping to freeze.
Caution: For areas having temperatures
of 0°F (-18°C) or lower, an additional
batt of insulation covering the joist and
the fire sprinkler piping should be used.
If this is not done, freeze -ups can occur
in the sprinkler piping.
INSULATION DETAILS
NTS
TO SYSTEM
SPARE CABINET
BASE OF RISER AT NODE
—ITT=T I I` JT1r1 I
MAINTAIN VA" ANINOEIVF1
CLEARANCE AROUND PIPE
RISER DETAIL
Ill=L1=Ill=1UIll=L1YLl 1=11=111-1
•I I I, � ILII I I�I I I�I I I-1 I I�I I ILI I I�I I I�I 11
11-111--
0 ' 1 2 ' 4
SCALE 1/2"=-11-0"
RISER MATERIAL LIST
ITEM #
QTY
SIZE
DESCRIPTION
MANUFACTURER
1. 1
2 1
3 1
4 1
5 1
6 1
7 1
2
1/,
1
11.4
6
6
CPVC GROOVED ADAPTER
VSR WATERFLOW SWTICH
PRESSURE GAUGE
THREADED BALL VALVE
CPVC GROOVED ADAPTER
PBA246 24v ELECTRIC ALARM BELL
SPARE HEAD CABINET
GENERIC
POTTER
ARGCO,
GENERIC
GENERIC
POTTER
ARGCO
SPARE HEAD CABINET
QTY
SIZE
DESCRIPTION
6 Y. GL4906 RESIDENTIAL SPRINKLER HEADS 155°
SPRINKLER HEAD WRENCH FOR GL4906
Sprinkler Legend •
Symbol
Manufacturer
Response
Type
SIN
K -Factor
Size
Temperature
Finish
Spacing
Quantity
Globe
.' Quick
Pendent
GL4906
4.9'
%
. ' 155`F
Brass
18 x 18
25
Globe
Quick
Sidewall
GL5626
5.6
'
155`F ,
White
20 x 20
1
Total = 26
RED HAWK
FIRE PROTECTION, LLC
4";&0 VdaD't
801 VALLEY AVE NW, SUITE D
PUYALLUP, WA 98371
PHONE: (253) 840-9900 FAX (800) 591-4382
WA CL# REDHAHF901OP
NICET Stamp
Approvals Required
TUKWILA FIRE MARSHAL
OWNER / ARCHITECT
Revisions
Contract With:
CARY LANG
CONSTRUCTION
29815 24th AVE SW
FEDERAL WAY, WA 98023
CONTACT: CARY LANG
Phone: 253-661-6880
Fax:
Contract Name:
ALLENTOWN 74
12516 50TH ST SO. TUKWILA WA
98178
PARCELL # 0179002655
/7 s -AP
Drawing Title
FIRE SPRINKLER AND
RISER PLAN
Key Plan
Date:
Job Number:
Designer:
Building Permit:
June 09, 2017
80079
BEN BERNARD
Drawing No.
FP 2.10