HomeMy WebLinkAboutPP - 360 UPLAND DR - SMART CLOSETS - PERMITS AND PLANS360 UPLAND DR ASSOCIATED PERMITS 17-F-092 91-S-335 83-S-1017 SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** Site Address: 360 Upland Drive Bldg.2 Tenant Name: Upland Drive Business Park King Co. Assessor's Tax No.: 8835100000 Suite Number: Floor: New Tenant? ❑- Yes - No Property Owner's Name: Upland Drive Business Park Mailing Address: 360 Upland Drive Tukwila WA 98188 City State Zip CONTACT PERSON -if there are questions about the submittal. Name: Sheramie Odell Day Telephone: 360.647.0110 EXT 327 Company Name: Guardian Security Mailing Address: 1501 Kentucky St. Bellingham, WA 98229 E-mail Address: sodell@guardiansecurity.com City State Zip Fax Number: Contractor's City of Tukwila Business License number: GUARDSS233K5 Total number of new/relocated devices or sprinkler heads: Valuation of Project (contractor's bid price): $ 500 Scope of Work (please provide detailed information): Install AES Radio to monitor existing system PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. PAID BUILDING OWNER OR AUTHORIZED AGENT: 201? e Digitally signed by Sheramie Odell + Signature: c' Date: 2017.05.1611:47:42 •-0T00' TUKWILA �) Date: 5.16.17 Sheramie Odell 8E60.647.0110 ext. 327 Print Name:_ Day Telephoner Plan Permit Api 360 UPLAND DR CC 1(.Zoo — TFD FP Form 8 e/ 17-F-092 TM Fui Data Modu[e Overview The AES -7794 IntelliPro FireTM is an add-on module for AES subscribers that enables transmission of full alarm zone data from an alarm panel to a central station over an established AES-IntelliNet network. AES subscribers with IntelliPro Fire can operate in applications with or without a phone line providing full emulation of the phone line for the alarm panel communicator. IntelliPro Fire supports most popular alarm commu- nication protocols including Contact ID and Pulse as well as Modem II and Modem III.* Easy Installation IntelliPro Fire easily installs in the subscriber housing and is powered from the transceiver module, requiring no additional power connections. AES sub- scribers can be ordered with IntelliPro Fire installed. IntelliPro to program using the AES Handheld Programmer. Fire is easy Features • Commercial fire alarm applications - with or without phone lines • Transmits full alarm data from any Contact ID or Pulse format fire alarm panel • Supports expanded event reporting from Bosch Modem II and Modem III alarm panels • Universal wireless alarm transmitter - works with most manufacturers' panels • Easy to install in AES subscriber • Easily programs using an AES Handheld Programmer • Option to monitor telephone lines *The AES -7794 IntelliPro Fire converts Modem Ile and Modem llla2 codes to Contact ID for transmis- sion over the IntelliNet network and supports those alarm panels listed in the table located at www.aes-intellinet.com/AES-IntelliNet_7094IntelliPro.html. This table will be updated as additional panels are tested. AES Corporation 1285 Newbury Street 1 Peabody, MA 01960 USA Call 800 -AES -NETS (800-237-6387) or +1 978-535-73101 Fax +1 978-535-73131 Email info@aes-intellinet.com Web www.aes-intellinet.com CORPORATION A. 7 • For Alarm Monitoring Technical Specifications • Transmits full data to AES receiver using Contact ID or Pulse formats • Formats Supported: Contact ID, Pulse 3+1, Pulse 4+1, Pulse 4+2, Modem Ile*, and Modem IIla2* I/O Connections • AES subscriber with power • Handheld/PC programming port • POTS incoming phone line • Phone output from alarm panel • Trouble output (form C relay) Size • 2.8 x 5.0 inches (7.1 cm x 12.7cm) Power Requirements • 12 VDC nominal, primary and backup power provided by the AES RF Transceiver Unit How to Order Model 7794 7744F-ULP 7788F-ULP Description IntelliPro Fire UL Fire Subscriber w/7794 (4 reversing polarity & 4 EOL inputs) UL Fire Subscriber w/7794 Wireless mesh networking is an innovative technology adopted by many industries with applications that need to communicate data over a large geographic area with a high level of reliability at a low total cost of ownership. The advanced design and 2 -way commu- nications capability provides easy installa- tion, expansion, and management when compared to alternative communication methods, both wired and wireless. Copyright 2011 AES Corporation • AES-IntelliNet is a registered trademark of AES Corporation 7794/11/03 ACCEPTED ID Without Comments pAs Noted in Reil Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: 5 -�- I '7 By: sit 4 E64.0.4. 5M.ok.. dal•. aSovt 11 -E'S . >IjIONILA FIRE DEPARTMENT Please ill 206-575-4407 and give this Fire Permit No. r' -F- oq- Ind exact address for shut - loyal or restoration approval. NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the inspector prior to commencement of Acceptance Testing of a;ny Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testis A e' • JAMES C. BUCHANAN COMPANY As iMUii:D The drawings affixed hereto have been FIRE PROTECTION C❑NTRACTIOevewed and accepted as meeting or 13742 97TH AVENUE N❑RTI-Ft0ed,r imam requirements of the KIRKLAND, WASHINGTON 913.-,nr of "'� M !; Fire Dept., E3ureau of Fire Prevention. Additions or revisions to these (206) 621-13a130 drawings after this date shall not be 121 ./ D47&C. I UD17/641 - co3 O PGAIJO D211) 7V12-1,0/ LA, WAS')I. Obi,Uue(S os oetng approIe;i or revi:;.' d z Q6 : 412/2 -IL z 9 B 1c rel,' .72-0/16/0M5 ; ZZ - A/ ?(t / 5° APT vr/JO(J N / A�KJC tJ Pell_ C/7Y 07 7Z/h iVfcA r_ C 1 •N i /I L 1/IL G ti 4 -P i 2-0z.; A027H 364 UPLAND DR 83-S-1017 /11P11.1 i 9-9 /i5 \ 1z7L 2'\" `�• 41011t Cr. (► . \.1\Q J C� +0® — - 2—/0- 1-0 PLAY') V /ZZLI sc,3ce: e X74 148179 GOMPREssOR CL.DSET • EXIST. O.N. DOD_ • `01.0 - 12).12. FREEZE4. ? — ip•••I- -.( - - I-4'--1 11- o- 1:0 - -/8 r — — — • • IK - •• — am* «C,— — — p II'4 "IMOD ammo •••• mown mom ---< ----- ---- I« L° -r I' s— i— .— — PLAN \/1 E L/J />; = I I - 0 NOTES: I FALL WANG ERS Td SE EYELET 44.//3/R LAC. SGREL.4) x 2%" LONG,. z� WAI.J.(, FROM PURL INS _I_ SG,QPE OF LAJOR-IG: ADD D2•{ PSnIDEPIT 5 TO (2) FRE-EZEIZS 45 I AND I SSP TO CLOSET. ..f -j CL NOV 251991 L P UPLAND DRIVE SRZ L.IJ/Z PC CAN!, GEM F950 340 5 ITE 3C.C. (MAIN OFF ice) S I TE L-OCATI ON n STRUCTURE TO CENTER /� LINE OF PIPE IN INCHES SPRINKLER LEGEND QQY�Y� SPRINKLER ORIFICE SIZES AND TYPE W 1' 2 16 8 6 2 SPRAY O • 1" 4 17 32 SPRAY 0 1" 1' 2 8 16 2 SIDEWALL a 4 1/2' I 4 1' 1" 1 DRY TYPE 2 O TEMP. RATING Q 165• 212• 286' !� 350• 500' • 0, 1/2 0 1 • 1/2 1/2 m 1/2 SPRINKLERS USED • SPRINKLER ORIFICE SIZE. TYPE i FINISH QUAN TEMP V2. Doz.,' PEN OEN,' 3 28C. O ssv BRZ 165 TOTAL. APPROVALS REQUIRED CITY O r TL.) K LA.' I L A REVISIONS MK DATE BY A A PROJECT NAME. HEAT CON 36.O UPLAND DRIVE TUKWILA, WA, 98188. CONTACT; PATRICIA 575- I333 FILE Grinnell FIRE PROTECTION SYSTEMS COMPANY 360 UPLAND DR 91-S-335 DESIGNER PAUL BO -LE I I I- 2.0-91 141-400187-A9 DATE JOB NUMBER TUKWILA FIRE DEPARTMENT, Please call: 575-4407 and give this job Ho, of 333C and wiazi address for shut. tbneeiarlrleataration approval ACCEPTED C . A': MENTS. 0 PER �T : E n i -A1 ; ED LETTER The drawings ai is e:.i hereto have been reviewe i an-Jsc ;:te i by the City of Tukwila Fire-'_ ,t. Al iiti Dns, deletions or r �i:s -, ::� :- i r .rmi gs after this date willx,�';s �,,t n ;e and win �=moi ] �...•,,. require of revised draei. Final acceptance is subject to field - inspection by a representative of this department DATE; BY CITY OF TUKWILA X75--4407