Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PP - 13045 MACADAM RD S - ISRAELITE CHURCH OF GOD - PERMITS AND PLANS
13045 MACADAM RD S ASSOCIATED PERMITS 13-F-169 10-F-217 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: 734/J .00! LS Site Address: 001-6 AfAt 4olAM R0k S. Suite Number: Floor: Tenant Name: SO.1 ;K GIloArCin D4! GOCk Property Owner's Name: L a-4 cv r;#1`0) New Tenant? ❑ - Yes jki - No Mailing Address: /30(0. /Yc.c•4o 03 . Tu itwi'fa L)64 St14 g City State Zip CONTACT PERSON -if there are questions about the submittal. Name: .SCd71t 14,44.1-5,0 Day Telephone: 'goo -364 - (55 S Company Name: Ace Fut 4- Seeuj' I4 iDDA f114,14n Cei"1- r .1 "( Mailing Address: Po '30x 3L4 0 7 l aCty t 4 9850 9 City State Zip E-mail Address: SAbcjtfsort P & Lr' C fr,',%C. CO Al Fax Number: Total number of newrelocated devices or sprinkler heads: 7 Valuation of Project (contractor's bid price)): S 21 2.2 . 00 Scope of Work (please provide detailed information): rtA S./A 11 3 Ali.) L tach otQ4ec4Z!PJ , l s hie, At e Dehc - ; 1 both , 2- Si -holo c.c PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time. for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Nam e:,5c0.-1 • A� �,-• Plan Permit App_doc Date: c/4>81/ 3 Day Telephone: 1-806-3V1' I ' 1'213 TFDFPFo=S Fire Alarm Plan For Addition r- • 2- r ADD-ON 0 2� EXISTING BUILDING 11tkt1 (E) Scale: 1/8" 1' - 0" North a -ram -a COOED e mmm 4eD G G 77 (E),(E)^? (E) (E) WP ,,(E) (E) (H Q ;S /14E) (E) ,---,(E) ,—,(E) ,--,(E) ,—,(E) H --HH H�.ti H; (E)/1,(E) RISER DIAGRAM Vicinity Map b tnI 'I '132nd Pi C7 3 (Codrga P Dc'w sn-^ Seattift Sou; Tukwila .013 GtroQ Symbol Legend Make/Model No. OANALOG/ADDRESSABLE S PHOTOELECTRIC SMOKE DETECTOR ESL 429 ORATE OF RISE HEAT DETECTOR POTTER RHA .7 r�1 i as HORN/STROBE COMBINATION ceiling mounted cd = candela rating of strobe light SYSTEM SENSOR PC2W "mil STROBE LIGHT wall mount @ 80' A.F.F. to bottom of back box cd = candela rating of strobe light SYSTEM SENSOR SR •7 ea (E) INDICATES EXISTING DEVICE Wire Legend WIRE NO. DESCRIPTION WIRE TYPE 1 NOTIFICATION GROUT (4) NO. 14 AWG FIRE RATED CABLE "FPLR 2 SLC (DATA LOOP) (2) NO. 18 AWG FIRE RATED CABLE *FPLR` Building Data ADDRESS: 13045 MACADAM RD S. TUKWILA, WA 98168 PARCEL NO.: 7341600125 TYPE OF CONSTRUCTION: FIRE ALARM OCCUPANCY: GROUP A PAID JUL. 2 2013 TUKWILA FIRE l(dJ 2) F182 Iv $i sig > 0, Sheet Number FA.1 .of1 ACCEPTED • wtthlyit s As No: o Per ihe J Letter These plans have been re,.;,z!',•,..:::(T; fl Tukwila Fire Prevention Bureau toi' Cun-ent City standards. Acceptance and omissions which do r. of adopted standards and ordirtanc:, 4,siolOty for the adequacy of ciesigi" :ksigner. Additions, deletiori ,:,i-awogs after this date will vo.. qufte a resubmittal of rev approval, Final acceptance is 110,; st and inspection by The Tukwila Fire Prevew Date: q 1 I:gh&r alrfeji ctout tregefot 52.gti kys“ (.441. kii50•Kr. NOTICE A completed, signed, Tukwirai Fire Department Pre-test"" Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing TUKWILA FIRE DEPARTMEIstr Please call 206-5754407 and give this Fire Permit No. and exact address for shut- down or restoration approval. p, Eft System Calculations BATTERY CALCULAT/ON- FACP PROJECTChurch of Neziah Tukwila, WA PANEL: 5700 Fire Alarm Control Panel Quantity System STANDBY(in Amps) ALARM in Amps) Current Total Current Current Total Current 1 Main Circuit Board 0.20000 0.20000 0.32500 0.32500 Addressable Devices (figure 20% of devices in alarm) 5 SK -Pull -SA Manual Pull Station 0.00027 0.00135 0.00027 0.00027 10 SK -Photo Photoelectric Smoke Detector 0.00027 0.00270 0.00027 0.00054 5 SK -Heat Heat detectoer 0.00027 0.00135 0.00027 0.00027 6 SK -Heat -HT High Temperature Heat Detector 0.00027 0.00162 0.00027 0.00054 6 RA100Z Remote LED Annunciator 0.00000 0.00000 0.01000 0.02000 Initiating Totals Notification Appliances 0.2070 0.3466 STANDBY(in Amps) ALARM in Amps) Current Total Current Current Total Current Quantity 4 Bells 1 GB10-24 0.000 0.000 0.100 0.100 Horn Strobes 6 GEC3-24WR, 15 candela 0.000 0.000 0.106 0.636 2 GEC3-24WR, 75 candela 0.000 0.000 0.208 0.416 Strobes 3 GES3-24WR, 15 candela 0.000 0.000 0.078 0.234 Weatherproof Strobes 1 WGES24-75WR 0.000 0.000 0.180 0.180 45 Signal Totals Standby Amps 0.0000 1.5660 Initiating Standby 0.2070 Notification Standby 0.0000 Standby Load Current (subtotal) 0.2070 X # of hours 24 Total Standby Load 4.968 Alarm Amps Initiating Alarm 0.3466 Notification Alarm 1.5660 • Alarm (sub total)1.9126 0.576 Alarm Time in Minutes / 60 (5 minutes = .0833) 0.0833 Total Alarm Load 0.1593 Total Standby + Total Alarm 5.128 Safety Margin +20% 1.026 Total Amp. Hrs. Required Battery Size= 6.15 7 A.H. 14 BATTERY /NFORMAT/ON- RF Unit PROJECT: Church of Neziah Tukwila, WA PANEL: AES 7788 RF Subscriber Unit PANEL: Per AES 7788 Technical Specifications Device Description From Device# Backup Battery Size for 24 Hour Standby : 7.5 A.H. VOLTAGE DROP CALCUL4T/4N PROJECT: Church of Neziah Tukwila, WA SIGNAL CIRCUIT: 1 PANEL: 5700 Fire Alarm Control Panel Device Description From Device# To Device# Device Load Footage Footage Doubled VDC Wire Size Resistance (OHM/foot) Segment Resistance Load (Amps) Voltage; Lost Horn Strobe, 75 candela FACP 1 0.208 5 10 20.40 14 0.00314 0.031 1.286 0.040 Horn Strobe, 15 candela 1 2 0.106 25 50 20.36 14 0.00314 0.157 1.078 0.169 Horn Strobe, 15 candela 2 3 0.106 25 50 20.19 14 0.00314 0.157 0.972 0.153 Horn Strobe, 15 candela 3 4 0.106 35 70 20.04 14 0.00314 0.220 0.866 0.190 Strobe, 15 candela 4 5 0.078 25 50 19.85 14 0.00314 0.157 0.760 0.119 Horn Strobe, 15 candela 5 6 0.106 45 90 19.73 14 0.00314 0.283 0.682 0.193 Strobe, 15 candela 6 7 0.078 40 80 19.54 14 0.00314 0.251 0.576 0.145 Horn Strobe, 75 candela 7 8 0.208 40 80 19.39 14 0.00314 0.251 0.498 0.125 Horn Strobe, 15 candela 8 9 0.106 35 70 19.27 14 0.00314 0.220 0.290 0.064 Strobe, 15 candela 9 10 0.078 40 80 19.20 14 0.00314 0.251 0.184 0.046 Horn Strobe, 15 candela 10 11 0.106 20 40 19.16 14 0.00314 0.126 0.106 0.013 TOTALS 1.286 _ 670 19.14 2.104 1.258 VOLTAGE DROP CALCULATION PROJECT: Church of Neziah Tukwila, WA SIGNAL CIRCUIT: 2 PANEL: 5700 Fire Alarm Control Panel Device Description From Device# To Device# Device Load Footage Footage Doubled VDC Wire Size Resistance (OHM/foot) Segment Resistance Load (Amps) Voltage Lost Bell FACP 1 0.100 30 60 20.40 14 0.00314 0.188 0.280 0.053 Strobe, Weatherproof 1 2 0.180 10 20 20.35 14 0.00314 0.063 0.180 0.011 Silent Knight TOTALS l' 0.280 X 80 20.34 _ 6 0.251 15 0.064 Per NFPA 72 2002 Edition, Section 7.3.2: Under all operating conditions, for a 24-V fire alarm system, the voltage on the NAC must be sufficient to operate all of the notification appliances so that they deliver the proper signal intensity. Often this is when the control unit's primary power supply has failed and the battery capacity is at its lowest point. UL 864, Standard for Control Units for Fire Signaling Systems, indicates a minimum value of 20.4V ( end of useful battery life ). This value then becomes the starting point for the voltage drop calculations. In the case of 24V appliances, when calculating voltage drop, both the listed and the nameplate operating voltage range will be 16V -33V. Therefore, 16V should be considered the minimum voltage that must be delivered to any appliance. Typical Mounting Elevations 72" A.F.F. TYPICAL FACP ELEVATION 44" A.F.F. TYPICAL MANUAL PULL STATION ELEVATION 6" B.F.C. 80" A.F.F. I R E TYPICAL STROBE / HORN STROBE ELEVATION Riser Diagram HT W HT ATTIC ,I/ Circuit Load: 1.29 Amps EOL Volts: 19.14 VDC 1-10 141 ,1/ 1-9 1-8 1-7 1-6 .1/ 1-S .1/ \1/ 1-4 15 1-3 1-2 1-1 2-2 Circuit Load: 0.28 Amps EOL Volts: 20.34 VDC 2-1 (1)(cal)LP FACP RFU 1-..120 VAC F.B.O. 120 VC F.B.O. (1)18/2 FPLP (typical) SECOND FLOOR FIRST FLOOR CRAWLSPACE (1) 18/2 FPLP (typical) -o Notes: 1. INSTALLATION SHALL CONFORM TO REQUIREMENTS OF N.F.P.A. 72 AND STATE AMENDMENTS. 2. WIRING METHODS AND MATERIAL SHALL CONFORM TO AND WITH ALL APPLICABLE SECTIONS OF N.E.C. ARTICLE 760. 3. INITIATING AND NOTIFICATION DEVICE POLARITY MUST BE OBSERVED. 4. ALL INITIATING AND NOTIFICATION CIRCUIT WIRING MUST BE SUPERVISED. 5. ALL WIRING, INCLUDING SHIELDS, MUST BE DRY AND FREE OF SHORTS AND GROUNDS. 6. 120VAC POWER IS NOT PERMITTED IN SAME CONDUIT WITH LOW VOLTAGE WIRING. 7. AUDIBLE DEVICES SHALL USE SYNCHRONIZED TEMPORAL (CODE 3) TONE. 8. STROBE DEVICES SHALL BE SYNCHRONIZED. 9. WIRE RUNS ON FLOOR PLANS ARE SHOWN DIAGRAMMATICALLY. EXACT LOCATIONS OF WIRE RUNS ARE TO BE DETERMINED IN THE FIELD. Style/Circuit Designations : INITIATING DEVICE CIRCUITS (IDC) SHALL BE CLASS "B", STYLE "B" SIGNALING LINE CIRCUITS (SLC) SHALL BE CLASS "B", STYLE "4", unless otherwise noted (U.O.N.) NOTIFICATION APPLIANCE CIRCUITS (NAC) SHALL BE CLASS "B" STYLE "Y", U.O.N. r'w wuA FIRE DEPART .1 Please call: 575-4467 and give this job NO. /0 -F -)I) and exact address for shut. "town or restoration approve/ Sequence Of Operations CAUSE EFFECT Annunciate Alarm At Control Panel Activate Horn / Strobe Circuits Activate Associated LED Indicator Transmit Signal Offiste Annunciate Trouble At Control Panel Manual Pull Station is Activated X X FACP X Smoke Detector is Activated X X 1 X Heat Detector is Activated X X Silent Knight X F Attic Heat Detector is Activated X X X X 10 Power Failure Heat Detector SK -Heat Silent Knight X X Wiring Fault SK -Heat -HT Silent Knight 6 X X Panel Trouble Silent Knight 6 l' X X Symbol List and Quantities ACCEPTED 0Without Comments MI As Noted in Red 0 Per The Attached Letter These plans have _ _ , r :tieva. ed by The Tukwila Fire Prevention Bure. r : ormance with current City standards. ;aubject to errors and omissions whirl:. • :ucnorize violations of adopted standards and ordiParices. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawingsafter this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and Inspection by The Tukwila Fire Prevention -Bureau. Date:10 -1 / -10 By: /1 - de 4'c) ID ,Sc poTh± 461d4ws0.c . bvcki4r Incline rtgr.,e cti d1/44a-,4,44.1rA- u � t,r.„ke, Symbol Description Model Number Manufacturer Total Fire Alarm Control Panel 5700 Silent Knight 1 FACP RF Subscriber Unit 7788 AES 1 RFU Manual Pull Station SK -Pull -SA Silent Knight 5 F 0 Photoelectric Smoke Detector SK -Photo Silent Knight 10 HD Heat Detector SK -Heat Silent Knight 5 HDHT Heat Detector, High Temperature SK -Heat -HT Silent Knight 6 Remote LED Indicator RA100Z Silent Knight 6 l' .1/ Horn Strobe, 15 candela GEC3 Series Gentex 6 15 ♦ 1 / Horn Strobe, 75 candela GEC3 Series Gentex 2 7s .1, Strobe, 15 candela GES3 Series Gentex 3 p1 1 / Weatherproof Strobe WGES24-75WR Gentex 1 7cd5 WP 0 Outside Bell GB10-24 Gentex 1 NOTICE A completed, signed, Tr il'wila Fire Department Pre -tea Certificate must be presented to the Inspector prior to commencement of Acceptia.. Testing of any Fire Alarm and Detection Systems. Failure of test will rrEj it in a Re-inspection_e termination of „?e -testing. Device Sequence Legend . 1 / Candela Rating ��. End -of -Line 1-1N Resistor Circuit # 'Device # PAID OCT72010 TUKWILA FIRE Z7 - Drawing Schedule: FA -1.0 Project Information FA -2.0 Floor Plan FA -3.0 Panel & Device Diagrams PLATEAU SECURITY 14201 SE Petrovitsky Rd. A3-178 Renton, WA 98058 (206) 851-7396 FILECCPY Church ofNezi�/i Drawn By: A. E -$Y Date: 1©fO&%2010 Scale: NON- REVISIONS ONE REVISIONS REV. DESCRIPTION DATE Project Information FIRE ALARM SYSTEM Sheet Number: FA -1 .0 / % ATTIC / / \ / \, / ATTIC \ / \ / \ / N / N %/ \\ / ti \ ATTIC STORAGE UPPER CLASSROOM ATTIC STORAGE MAIN SANCTUARY ATTIC 0 0 CRAWLSPACE ELEVATION VIEW SCALE : 1/4" = 1 '-O" Wire Legend Z 18/2 FPLP CABLE, SIGNALING LINE CIRCUIT V 14/2 FPLP CABLE, HORN/STROBE CIRCUIT NUMBERED SHEET NOTES: LOCATED IN ATTIC ABOVE. FIELD VERIFY EXACT LOCATION OF REMOTE LED INDICATOR. LOCATED IN CRAWLSPACE BELOW. 2-2 E'O1- - ✓ ATTIC ATTIC ATTIC 13'-0" ATTIC ATTIC STORAGE ATTIC ACCESS 0 r - UPPER CLASSROOM ATTIC STORAGE ATTIC CN 8 SECOND FLOOR PLAN SCALE : 1 /4" = 1 '-0" COVERED ENTRY 1-1 9'_0„ LOCKED DOOR. NOT AN EXIT z (typical) UP CLASSROOM 3 0 Z— ;.,(typical) L - J OFFICE/ SOUND RM. 1-2 SANCTUARY/ MAIN WORSHIP Q NURSERY 11'-o" V-0" STORAGE BATHROOM FIRST FLOOR PLAN SCALE : 1 /4" = 1'-0" PLATEAU SECURITY 14201 SE Petrovitsky Rd. A3-178 Renton, WA 98058 (206) 851-7396 Church cfNeziah Ai' Drawn By: A. EZY Date: 10/06/2010 Scale: 1/41 , 1' 0" REVISIONS REV. DESCRIPTION DATE Floor Plan FIRE ALARM SYSTEM Sheet Number: FA -2.0 120 VAC wiring by others 0 To RF Unit 0 J r rrq 0 LA PREVIOUS REVIEW STATUS ALARM SUPERVISORY TROUBLE SILENCE POWER 0 G 0 0 RESET SILENCE ACK l 1 4 7 f 2 5 0 3 t 6 l 9 r 0 ENTER [>, TELCO2 RING TIP I RINGONETIP I RING CO TIP RING TIP NC COM + A To RF Unit 1 I2VDC 250 mA max, Unsupervised Status Indicators Optional AES rno We -up Immo TO TRANSCE /0011,1 J4 Antenna Cut / Trouble Relay output 24 VDC 1 Amp Resistive Unsupervised AN Zone inputs Supervised Typical EOL Circuits For Fire circuits, prograin used zones as "F" for Fire Program unused zones as "8" for bypass Resistor Must be at End et Line in the Control Panel 2.2N AES Pa Progr 2.2K Ohm E.O.L. AES Part No. 02-0029.EtN. Typical Closed Contact Trigger Program as S Transformer Wiring must be in Conduit to E.O.L. o. 02.O025 -EOL. rsForS Earth Ground – Green Nut Use a ring lug connector and 18 gauge (min) wire to connect to a suitable earth , ground, such as a metal cold water - pipe. For separation of circuits, battery wires are covered with Teflon tubing / Black supervised For wiring diagram of 7067 IntelliTap See: 40-7067 Rev D 3/31/08 For Wiring Diagram of 7770 FireTap See: 40-7770 Rev 1 March 31, 2008 Transformer Enclosure AES 1640-ENCL With Transformer Power In: 16.5VAC, 40VA, Class 2 (dry) source only. Use AES p/n 1640, or Amseco p/n XF1640 To Notification Devices AES 7788 Series RF Subscriber Unit NOTIFICATION DEVICE 11 To Next Device or EOLR EOL Resistor To Next Device on SLC Loop RA100Z (Optional) SK Series Smoke Detector/Heat Detector To Next Device 4. on SLC Loop SLC Loop BATTERY BATTERY 5700 Fire Alarm Control Panel SK Series Manual Pull Station PLATEAU SECURITY 14201 SE Petrovitsky Rd. A3-178 Renton, WA 98058 (206) 851-7396 Church ofNezi�b Drawn By: Ar. P5Y Date: 10f06f2010 Scale: NON - REVISIONS REV. DESCRIPTION DATE Diagrams FIRE ALARM SYSTEM Sheet Number: r'A-3.0 0 •(...h., .�,, . .r J!:- 1 11�i (_1:...-1.9, �1 _� 11 J1 ,!l ! i1 1 TJI�'l , I l;l L.._..1 L_J ..... _: 1-_...1 :._.._: - ..... .. i..... , t.....1 ....__: TELCO2 RING TIP I RINGONETIP I RING CO TIP RING TIP NC COM + A To RF Unit 1 I2VDC 250 mA max, Unsupervised Status Indicators Optional AES rno We -up Immo TO TRANSCE /0011,1 J4 Antenna Cut / Trouble Relay output 24 VDC 1 Amp Resistive Unsupervised AN Zone inputs Supervised Typical EOL Circuits For Fire circuits, prograin used zones as "F" for Fire Program unused zones as "8" for bypass Resistor Must be at End et Line in the Control Panel 2.2N AES Pa Progr 2.2K Ohm E.O.L. AES Part No. 02-0029.EtN. Typical Closed Contact Trigger Program as S Transformer Wiring must be in Conduit to E.O.L. o. 02.O025 -EOL. rsForS Earth Ground – Green Nut Use a ring lug connector and 18 gauge (min) wire to connect to a suitable earth , ground, such as a metal cold water - pipe. For separation of circuits, battery wires are covered with Teflon tubing / Black supervised For wiring diagram of 7067 IntelliTap See: 40-7067 Rev D 3/31/08 For Wiring Diagram of 7770 FireTap See: 40-7770 Rev 1 March 31, 2008 Transformer Enclosure AES 1640-ENCL With Transformer Power In: 16.5VAC, 40VA, Class 2 (dry) source only. Use AES p/n 1640, or Amseco p/n XF1640 To Notification Devices AES 7788 Series RF Subscriber Unit NOTIFICATION DEVICE 11 To Next Device or EOLR EOL Resistor To Next Device on SLC Loop RA100Z (Optional) SK Series Smoke Detector/Heat Detector To Next Device 4. on SLC Loop SLC Loop BATTERY BATTERY 5700 Fire Alarm Control Panel SK Series Manual Pull Station PLATEAU SECURITY 14201 SE Petrovitsky Rd. A3-178 Renton, WA 98058 (206) 851-7396 Church ofNezi�b Drawn By: Ar. P5Y Date: 10f06f2010 Scale: NON - REVISIONS REV. DESCRIPTION DATE Diagrams FIRE ALARM SYSTEM Sheet Number: r'A-3.0 0