Loading...
HomeMy WebLinkAboutPP - 15044 MACADAM RD S - FOSTER CREEK II APARTMENTS - PERMITS AND PLANS15044 MACADAM RD S ASSOCIATED PERMITS 99-F-052 98-F-013 Fire One, ine. • I- 1 .. E., FIREOI*099KW FIRE PROTECTION SERVICE / SALES January 13, 2008 Tukwila Fire Department 444 Andover Park East Tukwila, WA, 98188 Attn: Al Metzler Re: South Center Apartments —15004 Macadam Rd. South Tukwila, WA, 98188 107 WASHINGTON BLVD ALGONA, WA 98001 (206) 575-0311 FAX (253) 735-4976 BREMERTON (360) 478-0428 Phone: 206 575-4407 Fax: 206 575-4439 Apartment K: Move existing Silent Knight 5207 Fire Alarm Panel N from inside of the apartment which was the Manager's Unit prior to Foster Creek take over, to outside in a Nema 3 Cabinet with heater — same wall. Existing was a Silent Knight 5230 Annunicator located outside in a STI enclosure. Dedicated power to the fire alarm panel and heater same circuit breaker from the apartment unit. Om( . 3 06:90E J 1. Annunicator — 5230 inside outside enclosure 2. Housing - Nema 3 Enclosure 3. Fire Panel - Silent Knight 5207 4. Heater - Nema Heater Thank you, Wayne Johnson 24 hour LIL- central station monitoring PAID 1 LUUU Tukwila Fire -5" 5"-W �75 WORKSHEET 1-1 CALCULATING TOTAL BACK-UP BATTERY LOAD FOR FIRE ALARM SYSTEMS 2/11/99 A B IS IA TYPE OF DEVICE f+.n. # OF DEVICE CURRENT PER DEVICE IDLE STATUS CURRENT PER DEVICE ALARM STATUS SUB TOTAL DEVICE CURRENT IDLE STATUS SUB TOTAL DEVICE CURRENT ALARM STATUS 1 520 COnt i 1 0.120 0.700 0.120 0.700 2 Weather Prop 2Horn 18 --- 0.023 --- 0.414 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 TOTALS FROM COLUMNS Is & IA SHEET 1-2(IF USED) = AMP. HOURS Is= SYSTEM STANDBY CURRENT Ts= TIME DURATION (60, HRS) COLUMN Is TOTAL DEVICE 0.120 CURRENT IDLE STATUS 1.114 COLUMN IA TOTAL DEVICE CURRENT ALARM STATUS la= J T J I CIVI IiL/1r1M IiURRCIV I `IF MORE SPACE IS NEEDED USE SHEET 1-2 TA= TIME DURATION IN ALARM (5 MIN.=0.0833) K = 1.25 BATTERY CAPACITY COEFFICENT [ ( Is X T5)+( IA X TA ) ] x K = A.H. ( 0.120 x24)+ ( 1.114 x0.0833dX1.25= 3.71599 TOTAL AMP.HRS. = 3.8 SIZE OF BATTERY PROVIDED : 70 15-0114( ,MGA( ,44 72d APT. APT. ®•—Down To ® 2nd Fir. APT. APT. Building A 3rd Floor Fire Alarm Plan 1/8" = 1' — 0" ,,,,,4 a --From 3rd Hr. 0 --Down To 1st Fir. Building A 2nd Floor Fire Alarm Plan 1/8" = 1, — 0" APT. APT. APT. APT. Down To T 2nd. Flr. From--; Bldg. B. APT. APT. APT. *8 DIDInc IA Fir. Down To -0 1st Flr. APT. From 2nd Flr. Building A 1st Floor Fire Alarm Plan 1/8" = 1' 0" Vicinty Map NOTES : 1. WIRING BETWEEN BUILDINGS TO BE RUN OVERHEAD PER N.E.C. STANDARDS. 2. ALL THE BUILDINGS HAVE A FL A T ROOF WITH NO ATTIC SPACES. 3. THERE ARE NO COMMON AREAS IN ANY OF THE BUILDINGS.(ie: LAUNDRY RvI.,ELECT. RM. ETC.) NOT TO SCALE TUKWILA FIRE DEPARTMENT', Please call: 575-4407 and give this job No. N-• and exact address for shut- down or restoration approval. 0 42-itc4/ 44. foAtze s etAI 14, tr.%2.►- , _76 cid l-- - 0 Without CornMents AaNttc:rjinNed Por The Attached Letter T heso. tZ ,^ is • h ':: i;{.•'en mie3w di by The Tukwila Fire i ccii ifOr an e !cJlth Current city A;:t:'sptu hoe is s1.1bj., . to errors and • •„t•,. ; :€ ',AINCi) not.do ..�,i,.: � riw: vioiat,cns of adopted end i"d i iY i i J Ti"t,. r s; on ti y for the ,: cl agLitzloy of deli n i'asts t taliy with the designer. Additions, dol tions or revisions to these drawings after this date will void this acceptance and will require a • resubrriittal of revised drawings for.subsequent approval. Final acceptance is subject to field teat and inspection by The Tukwila Fire Prevention Bureau. Date: .//1,//1 By: SYMBOL LEGEND EOL FIRE ALARM CCNIROL PAt'EL MOWED N WEAL ftER PROOF ENOLOSLRE . . WEATI-ER PROOF MAW& FU1 STATION WALL MOW 0 48 NOES AFF. WEATifR PROOF FRE ALARM HORN WALL NOWT 0 7-0” AFF. UDICATES END OF LIE DEVICE Project Name SOLDUTHCENTER APARTMENTS 15038 MACADAM RD. S. TU<WLA, WA. 98033 2/10/99 FRE ALARM • ,;. �,, . 5cda As Shown ,.Tr ALARMCI055CW cd BY: Date Revision Date Revision 1' ACE FIRE !l< SECURITY SYSTEMS 1-800454-1555Sheet: A pril.a et Are Oa.Mr, AN. P.O. BOX 3383 LACEY, WA. 98509 1 Of• 4 IMMEETM FEB 1 2, 1°99 APT. APT. A To Bldg. A—° 4_ Down To -77 3rd Flr. APT. APT. From -0 Bldg. C v Building B 3rd Floor Fire Alarm Plan APT. APT. 1/8" = 1' — 0" 2 IV— Up 4.., Down To -7 1st Fir. APT. APT. From 3rd Fir. Building B 2nd Floor Fire Alarm Plan APT. APT. 1/8" = 1' — 0" i APT. From -0 2nd Flr. APT. Building B 1st Floor Fire Alarm Plan 1/8" = 1' — 0" Project Name SOUTHCEVER APARTMENTS 15040 MACADAM RD. S. TLKWLA, WA. 98033 Data 2/10/99 ayerte rn ' `FRE ALARM cx J.F. 1:411a As shown sow . ALARMCI055CW O1°4 BY Pate Revision - Date i evision ACE FIRE a 1-11ao-31'ii4-1868 SECURITY SYSTEMS A NO* a eM Mimi OerMti las. P.O. BOX 3383 LACEY, WA. 98509 Sheen 2 Of. 4 APT. APT. To Bldg. C-0 2 Down To 3rd Fir. APT. APT. Bldg. D From Building C 3rd Floor Fire Alarm Plan APT. APT. 1/8" = 1' — 0" Down To 1st Fir. From --0 3rd Fir. APT. APT. Building C 2nd Floor Fire Alarm Plan 1/8" = 1' — 0" Building C 1st Floor Fire Alarm Plan 1/8" = 1' — 0" Project Name: SOUTHCfaaiTER APARTMENTS 15042 MACADAM RD. S. TIKWLA, WA. 98033 Qate: 2/>d/9 Yirtarn ' FRE ALARA xarr► t1Y% JF 5cd« As Smarm °" 7trs A LARMC#U55CW 4Pra ai °Y Date Rzcn Gate Rev an ACE FIRE i t-titl0-i14-4111 SECURITY SYSTEMS A riiir NAM arm •a P.O. BOX 3363 LACEY, WA. 98509 Sheen 3 Of: APT. APT. ®--Down To 2nd Fir. APT. APT. Building D 3rd Floor Fire Alarm Plan 1/8" = 1' - 0" o --Down To 2nd Fir. Building D 2nd Floor Fire Alarm Pian APT. APT. 1/8" = 1' - 0" APT. APT. Building D 1st Floor Fire Alarm Plan 1/8" = 1' - on APT. APT. Up To -0 2nd Fir. w APT. APT. ZONE 4 ZOtE 1 ZONE DPSCRPTION ZOtES t BULD1VG A MAMJAL PULL STAT IS 2 BULDIVG B MANUAL PLL SrA T1ONS .3 9ULDIfVG C MAM JAL PILL STATIONS 4. Bt DI'G D MAM'JAL PDLL STA TIOIIS 5. — 8. SPARES Zl 3 "' ZOtE 2EFE SLENT NIIGHT 520K7 FRE ALARM CONTROL COMMUNICATOR br OCT. /I „crav as /2 X3 trxw arr. /J X3 teRN arr. /4 PI42E USE /1� T !VC —0 PFT E L6E /2 F? I iTORti COMECT DEDICATED 120VAC GROUT F 4? PRIMRY POWER r7/SER DIAGRAM Project Name SOIJTHCEIDITER APAR"TL€NTS 15044 MACADAM RD. S. TU(WLA, WA. 98033 bates 2/10/99 i y m` ALAI•JF. As Shawn ALARMCI055CW ,W.O1i d er- Date Revlon Date R Sian , ACE FIRE i 00-1a4-1146 SECURITY SYSTEMS 1-i A a1 *i N Alms ash ka P.O. BOX 3383 LACEY, WA. 98509 . Sheet 4 _Of- 4