HomeMy WebLinkAboutPP - 16828 SOUTHCENTER PKWY - MAX'S RESTAURANT - PERMITS AND PLANS16828 SOUTHCENTER PKWY ASSOCIATED PERMITS 19-F-027 19-S-012 19-H-042 g00% 4ist CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 AID 2719 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be oenietc in order to be aid fw plan reviewT f ILAFIRE **PLEASE PRINT** SITE LOCATION King Co. Assessor's Tax No.: Site Address: \t1S2S Sc, hte Pyr 1)ar Suite Number. Floor Tenant Name: 1(yANC S 21Y'O\y'\-'\"' New Tenant? D- Yes ❑ - No Property Owner's Name: Mailing Address: CONTACT PERSON -if there arequestions about the subnittnl. Name: Cf NeC51\-- �'� O�\Okf C ,, Day T : 2�y u 7[ 6 O\ Y\ 1-\f- n, )y -NG City State Tap Company Name: Mailing Address_ [ d: E-mail Address: J ��$ 1 CoVC—Y LW n (� .corn Fax Number NICET III number 7 s City of Tukwila 1044' /09/. CC-� B/usLicense number: SUS .699-5-8 /2- siiness Total number of new/relocated devices or sprinider heads: ' / 7 Valuation of Project (contractor's bid price): $ 5, CO3. Scope of Work (please provide detailed ):Md (q7) 7) )'?fadS PERMIT APPLICATION NOTES Vahae of Construction — In all uses, a value of consttpction amount should be entered by the applicant. This figure will be reviewed and is subject to possible; revision by the Fire Marshal to comply with current fee schedule& Expiration of Plan Reviewv•Every permit issued shall become invalid uales1'thie work on the site authorized by such permit is commenced 'villin 1110 days after its issriance,,or lithe work authorized on the site by suckpermil is amended or abandoned for a period of I80 {lays aper the time the work is commenced The Fire Marshal is authorized to grant, in .. writing, one or more extensitms of time, for periods not mere than 180 days each. The exon shall be requested in writing and justifiable cause dusted. I HEREBY CERTIFY THAT I HAVE READ 4ND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TSO APPLY FOR THIS PERMIT. BUILDING DINNER OR AUTHORIZED AGENT: Signadme: w" %5 Date: O hint Name:/ L 5/c DT : t 4g°f-7(p(Qf - Plan Permit App.doc 822/14 TFDFP Fonn 8' SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** 'n `�� ,, ` King Co. Assessor's Tax No.:,��D2�i lr,�� Site Address:l Vc ��.)�t \C -.?K YMCA P�c�WI� , Suite Number: Floor: Tenant Name: DX �� TEauw\-\- New Tenant? ❑ - Yes 547 No Property Owner's Name:36 `fie". �\ l AULVCI u Mailing Address: l � 4 1(�. V,C� . , l uk\ \ ck l State Zip CONTACT PERSON -if there are questions about the submittal. Company Name: Nrkl iCt 1i: Mailing Address: \1'k \ Pe. S E-mail Address: City Day Telephone:(D )( 6- `ei `T.p 1CrA-WIE, 01\ fltA)Y-id City State Zip Fax Number: Con i : ctor's City of Tukwila NICET III number: Business License number:105-- LIT ( 4 Total number of new/relocated devices or sprinlder heads: Valuation of Project (contractor's bid price): $ 4 Q1Q Scope of Work (please provide detailed information): 1i_, f),\(X( r (Adalam Vk.)(e\6.cizip. PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name: Plan Permit App.doc rvuS3anv\ Date:\ iq Day Telephone: (pall) 8/22/14 TFD FP Form 8 • CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATIO Applications and plans must be complete in order to be accepted for plan re FIRE PROTECTION SYSTEMS PERMIT APPLICATIOri **PLEASE PRINT** ..........7 SITE LOCATION King Co. Assessor's Tax No.: Site Address: /14 2' CC A. ee-i1 1.L yo) k Suite Number: Floor: Tenant Name: /Vt d x s )2-e-- A New Tenant? - Yes ❑ - No Property Owner's Name: Mailing Address: City State Zip CONTACT PERSON -if there are questions about the submittal. Name: Cl/y:4 )•19YUI( Day Telephone: 2L., 4- 22 7 527j r Dr, lL 1) -ye , '�- Mailing Address: 2 5�`. / VD City State Zip E-mail Address: F)1.%4 yjk Sot A S1 .g yG/Jfeti ' Fax Number: Contractor's City of Tukwila NICET III number: Business License number: rypyjir 01,9-6'ze Total number of new/relocated devices or sprinkler heads: 2 O Valuation of Project (contractor's bid price): $ 32-00 Scope of Work (please provide detailed information): At' / t t f fie ` .g66 4A, �! I,040 Company Name: PERMIT APPLICATION NOTES Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE 4� UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY V FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name: r �Q ›, a y" Plan Permit App.doc PAID FEB 23 2019 r TUKWILA FIRE Date: 2 -le" Day Telephone: ,mG '121. 8/22/14 TFD FP Form 8 FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Max's Restaurant 16828 Southcenter Parkway Permit No.: 19-S-012 Date: January 24, 2019 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2'h inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). • Flexible sprinkler hose bends shall not exceed the maximum radius permitted by the listing • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • All interior control valves shall be readily accessible, labeled and located not more than 6 ft. above the floor. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more sprinkler heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2016 Edition. FIRE DEPARTMENT HOOD SUPPRESSION PLAN REVIEW COMMENTS Project Name: Max's Restaurant 16830 Southcenter Parkway Permit No.: 19-H-042 Date: March 11, 2019 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Nozzle heights above appliances to be per manufacturers installation guidelines. • Fryers shall be installed with at least a 16 inch space between the fryer and surface flames from adjacent cooking equipment or a minimum 8 inch high steel or tempered glass baffle plate shall be installed between the appliances. • Upon activation of the suppression system, the make-up air supply will shut off and the exhaust will keep running. • Type 1 hood systems shall be designed and installed to automatically activate the exhaust system whenever cooking operations occur. The activation of the exhaust system shall occur through an interlock with the cooking appliances, by means of heat sensors or by means of other approved methods. • Activation of the suppression system shall shunt all electrical power under the hood as well as the gas supply. • Install a "K" rated portable fire extinguisher within 30 ft. of the cooking equipment. • The hood suppression system shall be monitored by a U.L. Central Monitoring Station. • If code compliant fire alarm notification is not already in place in the kitchen, a minimum 110 candela horn/strobe shall be installed above the kitchen hood suppression system manual pull station at a height of 80 inches above the floor. • A separate fire alarm permit from the Tukwila Fire Department is required for all fire alarm work. • The suppression system manual pull station shall be located no closer than 10 ft. and no farther than 20 ft. from the cooking equipment and be placed at a height of 42 to 48 inches above the floor. • The inside lower edge of the hood shall overhang or extend a horizontal distance of not less than 6 inches beyond the edge of the top horizontal surface of the appliance on all open sides. The vertical distance between the front lower lip of the hood and such surface shall not exceed 4 feet. • If cooking appliances are wheeled, the appliance wheels shall be set in tracks permanently mounted to the floor to ensure appliance is returned to original location if moved for cleaning or maintenance. NOZZLE HEIGHT 42 IN PIP SIZE IS 1/2 total flow point 11 maxis rest 16828 soutcenter park tukwila wa 98180 • Amerex kp 3.75 fire suppression system ul 300 FUSIBLE LINK Amerex KP 3.75 maximun flow point 11 ECHANICAL GAS VALVES CO ON 11984 RANGE RANGE 18x18 18x18 0) +.� 1I 24x24 13729 13729 tilting skiller stemer 24x36 Z w 0 24x36 All cooking equipment undder the hood shll shut off when system is actuated & make up air unit and gas shut valve to.fire suppression system shall be connected to the fire alarm system Installed by Frank fire protection inc 206 229 5245 450 MANUAL PULL 48" HEIGHT K CLASS FIRE EXTI PAD EB 2�3 019 TUKWILA -IRE NOZZLE HEIGHT 42 IN PIP SIZE 318 1/2 total flow point 11 maxis rest 16828 soutcenter park tukwila wa 98180 • Amerex kp 3.75 fire suppression system ul 300 hood 20 Amerex KP 3.75 maximun flow point 11 ECHANICAL GAS VALVES DUCT 12x18 DUCT 12x18 FUSIBLE LINK 16416 16416 1T 16416 16416 11982 1982 L1984 Cr CO rn RANGE RANGE 18x18 18x18 E v 24x24 13729 13729 tilting skiller stemer 24x36 Z w 0 24x36 All cooking equipment undder the hood shll shut off when system is actuated & make up air unit and gas shut valve to.fire suppression system shall be connected to the fire alarm system Installed by Frank fire protection inc 206 229 5245 EXIT 450 MANUAL PULL 48" HEIGHT K CLASS FIRE EXTI 1 S F� FIRE T ALARM SYSTEM ILA, WASHINGTON Tu.v..•iLyA FIRE DEPARTMENT Please call 2O5- 75- O7 and give this Fire Permit NO. and exact ilddr ex.'s for shut- down hutdown or restoration approval. EET NU V SHEET TITLE SYSTEM I \ FO VIATI O I\ & TYPICAL DETAILS r,) SI \GL \ E DIAGAV & CALCULATIONS A— J FLOOR PLA \ FRE ALAR v SYSTEV SHEET INDEX SUPPLY AND INSTALLATION OF NEW HORN/STROBES & STROBES FOR THIS NEW TENANT IMPROVEMENT SCOPE OF WORK QUANTITY SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT 10 5 BPS REMOTE BOOSTER POWER SUPPLY E (EXISTING) PAD -3 SIEMENS EXISTING 66" A.F.F. TO TOP MANUAL PULL nE STATION (EXISTING) MSI -1 OB SIEMENS EXISTING 48" A.F.F. TO CENTER DUAL INPUT MONITOR MODULE TRI—D SIEMENS 4S BOX VERIFY IN FIELD SM SYNC MDL3R SYSTEM SENSOR 4S BOX VERIFY MODULE IN FIELD 8 FIRE ALARM HORN STROBE PC2WL SYSTEM SENSOR 4S BOX CEILING FIRE ALARM STROBE SCWL SYSTEM SENSOR 4S BOX CEILING 3wP FIRE ALARM HORN STROBE (WEATHERPROOF) PC2RK SYSTEM SENSOR PLASTIC WP BACKBOX PROVIDED CEILING END—OF—LINE RESISTOR N/A N/A N/A N/A A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A E EXISTING DEVICE N/A N/A N/A N/A WP WEATHERPROOF DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT N/A N/A N/A N/A APPLICABLE RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT N/A N/A N/A N/A REMOVE BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE D DATA LINE - ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPLP RED (JACKET) S SIGNALING CIRCUIT TWO #14 FPLP RED (JACKET) I INITIATION CIRCUIT TWO #16 FPLP RED (JACKET) 0 GND N AC TBI 0 0 0 [ 1 0[ O O 00 EXISTING SIEMENS PAD -3 POWER SUPPLY (IN ELECTRICAL ROOM) 0 INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX 1 + 1— 1 2+ 2— 2 NC C NO + — + — + — + — + — TB2 0 0 0 0 0 0 0 3.6k EOL EXISTING PAD -3 POWER SUPPLY WIRING DETAIL CEILIN TILE 0 0 0 0 0 SPARE 1 1 EXISTING NAC CIRCUIT S1 SUPPORT BRIDGE 7- 4S BOX <40> CEILING HORN/STROBE HARD LID CEILING HORN/STROBE MOUNTING (DROP CEILING) EOL SUPPORT BRIDGE 4S BOX CEILING HORN/STROBE 0 0 � HORN CONTROL ZONE 1 IN 0 ZONE 2 0 O IN O SLAVE O IN 0 ZONE 10 OUT 0 ZONE 26- OUT 0OUT 0 NAC O SLAVE IN SLAVE O OUT 0 J )( Without Comments ❑ As Noted in Red ❑ Per The Attachd Letter "mese plans have been reviewed by The Tukwila Fire -entlon Bureau tn. conformance ,r ;, current City ndards. Acceo.a ?(:e i. subject re; . rror;: and ;1i; ions w Icr ?: 6ti hOrIze "lO1%3,:i01' S 0i addpled— odards and ord nFn ? The responsicill y for the -quacy of desir,..: , `otaHV with the designer. .0ditions, delet1oh ,,:,visions to these drawings after --his date wlll void tt1 _ < c,-e'prance and >,.v it require a ..zubmittai of revises; d,-avvinrs for subsequent approval Final acceptance is subject: W field test and inspection by The Tukwila Fire Prevention Bureau. Date: 2 - 2-7--1 9 By: TO NAC CK I 82 MDL3R SYNC MODULE WIRING DETAIL HORN/STROBE MOUNTING (HARD LID) TYPICAL NAC CIRCUIT WIRING DETAIL EXISTING MSI -1 OB MANUAL PULL STATION '7/ /2 70-17-1 Sit &II3 Hal Lc ° 4 ._&;5 J TRI -D KITCHEN HOOD (470 -OHMS) KITCHEN HOOD MONITOR WIRING DETAIL PAID JH 1 312019 TU ILA ARE 06- RONALD c RONALD MANSFIELD JR. NICET LEVEL IV CERT. #111878 EXP. 09/01/2019 i to RELEASE/REVISIONS m 11_] DESCRIPTION SHOP DRAWINGS w 1— C) 0 co < co co c�OI-- W� • Zcc w up_ < 0< < 1S WD< CC 0 LL tXJ SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BI: T. QUAALE DATE: 01/30/19 BACKROUND PLAN PROVIDED Y: WIRE LEGEND TYPICAL MOUNTING AND WIRING DIAGRAM opyng 1 uar• ian ecurl Y Ys ems, Inc. ATI—Rights Reserved \OB NUMBER:37259-1 SHEET FA 01 A B C D E F G H I ,J K FIRE ALARM BOOSTER Project: MAX'S RESTAURANT Panel: EXISTING SIEMENS PAD Date: January 31,2019 Module/Device POWER -3 REMOTE Qty SUPPLY POWER Standby (mA) BATTERY SUPPLY Total Standby (rnA) CALCULATION Alarm (mA) Total Alarm (mA) Power Module 1 15 15 0 140 140 0 TOTAL FIRE ALARM POWER SUPPLY 15 140 Auxiliary Device Current 0 0 Notification Appliance Load (Max. Total / mA) 0 2138 Total(A)= 15 Total(B)= 2278 CA L CULA TION Total current ratings of all devices in system (line A + line B + line C) 15 2278 Total current ratings converted to amperes (line D x .001) 0.015 2.278 Number of standby hours (24 or 60 per NFPA 72, Chapter 1, 1-5.2.5). 24 Multiply lines E and F Total Standby AH 0.36 Alarm sounding period in hours (5 mins+ .0833 hours) 0.0833 Multiply lines E and H Total Alarm AH 0.1897574 Add lines G and I Total Standby and Alarm AH 0.5497574 Multiply line J by 1.2 (20% extra insurance to meet desired performance) 0.65970888 RECOMMNEDED MINIMUM BATTERY SIZE 12VDC 7.0 AMP -HR *** RECOMMENDED MINIMUM BATTERY SIZE = 12VDC 7.0 AMP -HOUR *** Notification Appliance Circuit Detail PROJECT: MAX'S RESTAURANT Panel: EXISTING SIEMENS PAD -3 BOOSTER POWER SUPPLY Wire Resistance 2.58 Date: January 31, 2019 CURRENT TOTAL= 2138.00 G -GW {dil5cd 87 261 3Ocd; @75cd 222 0 95cd 15cd Ocd DEVICES 8 TOTAL mA= 292 Total Wire Resistance (R ) Total Device Load, Amps Voltage Drop ( E ) 792 14 138 23.44 792 ( WL * 2 ) * (R/ft) (Tota 1 Cct Load) (E=1*R) 0.71 0.79 0.56 Ocd 75cd P21►L 95cd SCWL 615cd PC2RK 15cd DEVICES 7 65 41 79 TOTAL mA e Resistance (R ) vice Load, Amps (I)i Drop(E) 0 41 0 702 14 325 22.82 ( WL * 2 ) * (R/ft) (Total Cct Load) (E= I * R) 24 - E) 702 1.68 0.70 1.18 22.82 PC2WL 15cd PC20cd PC2WL @75cd PC2/L 95cd SCWL d{-,i15cd PC2Rk,@15cd DEVICES 10 CALCULATIONS 71 142 80 0 0 143 65 41 79 TOTAL mA= Total Wire Resistance (R ) Total Device Load, Amps (I) Voltage Drop ( E ) EOL Voltage 164 8 644 14 366 22.78 ( WL * 2 )* (R/ft) (Total Cct Load) (E= 1 * R) 24-E) 644 1.89 0.64 1.22 22.78 � MAX'S RESTAURANT f.l. r D E c DM TO KITCHEN HOOD S3-1 S3-2 S3-3 S3-4 S3-5 S3-6 S3-7 S3-8 S3-9 S3-10 15Cd 15Cd 15Cd 30Cd 30Cd 15Cd 15Cd 15Cd 15Cd 15Cd S --co S2-1 S2-2 S2-3 S2-4 S2-5 S2-6 S2-7 15Cd 30Cd 15Cd 15Cd 75Cd 75Cd 75Cd BPS E (ELECTRICAL ROOM) EXISTING NAC CIRCUIT Si ( (SEE LOAD CALCULATIONS) SINGLE LINE DIAGRAM EOL S2 EOL S3 MAX'S RESTAURANT T.I. RONALD MANSFIELD JR. NICET LEVEL IV CERT. #111878 EXP. 09/01/2019 Copyright 2014 by Guardian Security Systems, Inc. All Rights Reserved CC L RELEASE/REVISIONS OD 0 DESCRIPTION SHOP DRAWINGS w 0 rn 0 0 co o CC D o- b a— c>1.3 z C/ wQ.) W CC �z� '-" o -i w— oo (01- SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 01/30/19 BACKROUND PLAN PROViD0 BY: \OB NUMBER:37259— i} SHEET .444 4 4,44 44, t4E41,1 EIE (444.44444,4P44 ER,4,444,444444144,44.4‘ 44404,44,44 44E44 •EIPIP4441.4.4444,14 44444:444 4/6 et,tOtttd.'0.,,,,,MMWAYtitg..PWL.tvtLtt..Mt.htltttki‘.4.6,1,Ph1.'.0 EtEE \ itEk40,0P <Pa, !,04, tE IWA!!!\ ktE.414.1441'...1444 E' Ea.k. foht,to'4.I !OVA. t k‘.144f1 ,E$VENittalf.EMNIO Ws, 'f.dthEr,ttt, 444,44443r, ttit Amt, 4.0;0',Ifft44 1E, 7 taly.f.ftlt t 4 4. - - , . • 1•11P FLAGNOTES: TO EXISTING BPS BOOSTER POWER SUPPLY IN ELECTRICAL ROOM. KITCHEN HOOD MONITOR MODULE. FIELD VERIFY EXACT LOCATION. • ;‘^ "%.4:11 Evi ' EE • • I444 44' EsE • "' LEr4enaneraria913 EVE:4013 E M ERG EN EXIT UTILITh" R CI M ,1_,,,froffirc , :171E11E; EOL S3 PRonu( ;Tr 88-4 AREA 30Cd WP CREW AREA, S3-9 15Cd S3-3 k--, Witdij — I rs,1 t..K CHILLER 11 f;41 :4--, , S3-2 15Cd -- IN Z ER K ,II.,'Itt t I ikal.il 3 ncs,'HwAqH1 AREA 15Cd • CORRIDOR/ EIMERGENCY EXIT S3-5 30Cd I 1 P R NAI.= OFFICE D A LJ /'. ARES22 30Cd("--, \,3 IOLK 1-0JU r.„1 PACKAGING STORAGE S2-1 15Cd 1 S2-5 ,. figg Ali --7 1 IOLK 1-0JU r.„1 PACKAGING STORAGE S2-1 15Cd RECEPTION HALL .J1 MAI HALL ji Ffl i I • i 1 • 5 I ! c t 1 I r ‘.._:_...-• 1, 1 !,. i S2-5 5 Ali --7 RECEPTION HALL .J1 MAI HALL ji Ffl i I • i 1 • 5 I ! c t 1 I r ‘.._:_...-• 1, 1 F-1 1 Li cLi it 1 1 1 I I -I i 1 f . E I i I 1 d I I f \ 4f 'I i 4 I EOL S2-6 1 Fl• I I I _ ! ) 75Cd i 1 ! r 1 iI II i ! ( I [ 1 I 1 I i .. 1 . 1 Ii 1 1 I 1 ! ! I ----,.; i 1 i 4 h... .4 t... ....-_-„-.....- fl I 1. ) 1 nn 1 I j I I I E !,. i S2-5 F-1 1 Li cLi it 1 1 1 I I -I i 1 f . E I i I 1 d I I f \ 4f 'I i 4 I EOL S2-6 1 Fl• I I I _ ! ) 75Cd i 1 ! r 1 iI II i ! ( I [ 1 I 1 I i .. 1 . 1 Ii 1 1 I 1 ! ! I ----,.; i 1 i 4 h... .4 t... ....-_-„-.....- fl I 1. ) 1 nn 1 I j I I I E .... . 1 I •,.1-1,,, ;',.-_-,",,,;() . , is. ES\ 41 \ \ -1 r ENTRANCE ir----7-- '''-, t --------Z:', i v------,4 ,/, -,:--- \•.., ...,-----. I 1 i 1 i I 1 it I i 1 (_! !.,__) __J /// FLOOR PLAN — FIRE ALARM SYSTEM SCALE: 1/4" = 1'0" RONALD MANSFIELD JR. NICET LEVEL IV CERT. #111878 EXP. 09/01/2019 Copyright 2014 by Guardian Security Systems, Inc. All Rights Reserved LL RELEASE/REVISIONS DESCRIPTION SHOP DRAWINGS LU (cCALE: 1/4" = 0" DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE:01/30/ BACKROUND PLAN PROVIDED BY: OB NUMBER: 37259-"y C SHEET FA -0,1 !,. i t 5 , .... . 1 I •,.1-1,,, ;',.-_-,",,,;() . , is. ES\ 41 \ \ -1 r ENTRANCE ir----7-- '''-, t --------Z:', i v------,4 ,/, -,:--- \•.., ...,-----. I 1 i 1 i I 1 it I i 1 (_! !.,__) __J /// FLOOR PLAN — FIRE ALARM SYSTEM SCALE: 1/4" = 1'0" RONALD MANSFIELD JR. NICET LEVEL IV CERT. #111878 EXP. 09/01/2019 Copyright 2014 by Guardian Security Systems, Inc. All Rights Reserved LL RELEASE/REVISIONS DESCRIPTION SHOP DRAWINGS LU (cCALE: 1/4" = 0" DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE:01/30/ BACKROUND PLAN PROVIDED BY: OB NUMBER: 37259-"y C SHEET FA -0,1 Corrugated stainless steel hose with stainless steel braid available in 2'. 3',4%5' 8 6' Iegnths • Elexheadornmerciai Ceiling Unit • T -Bar Ceiling Installation • Model #2024,2036,2048,2060,2072 NOT LESS THAN 2` • NtMINAL WIDTH, ( 1 1/2' ) NUT LESS THAN 3` NOMINAL THICKNESS (2 l/2 ' ) ( DEPTH DR: SIDE II VERTICAL MEMBER ) TU -UK Ii.A FIRE DEPARTMENT Please Gall 206-575-4407 End give this Fire Permit los i9 -S -ora - and exact address for shut- down or restoration approval. Without Cornments As Noted in Red Per The Attached Letter; I ; glans have been reviewed by The Tuley i( ...ntior: Bureau for conformance with curer► • s, :ards. Acceptance is subject to errors' d :. ":;`:.: :.,sons which do not authorize vio;ationif:< CNAd' yards ann orjinances. The responsibilty,S t taacy a design resp tow* 4/vItlh•(11Q dec;i9i Icons, deletions or revisions to thg$44tEE+# irk fifer':: .me. will voic! this cceptance . esubmittai of revised dra' Ings for subs ti.eilt apf�,rov t • Design per NFPA 13 — Ordinary Hazard - Restaurant All materials to be new, U.L. listed and F.M. approved All heads to be .at least 6' apart with n o obstructions Existing uprights to remain • 44 — Add Globe Model GL5651 Standard Response 155° Chrome Pendents %2 x %2 • 2 - Add 2 Globe GL5679 Standard Response 200° Dry Pendents % x1/2 (skirt -& sleeve) - • 1— Add Globe Model GL5661 Standard Response 175° Brass Upright'/2 x'/2 GaRTtF OF ? AMNOY rtmt PRCtYRC 70,}IRINKtAR 1::97 41091-t;4: .S ` �'; Gratin Firo Prn1c lr�OWNFr l: ; r ; REFLECTED CEILING PLAN 1/4" =11-0" JOSELITO & LOLITA SANTOS 16828 SOUTHCENTER PARKWAY TUKWILA, WASHINGTON 98188 ,7k7, 4 ( '. ,a C V t. II. 411) __./_____________ 7°11 CO 4• , Corrugated stainless steel hose with stainless steel braid available in 2'. 3',4%5' 8 6' Iegnths • Elexheadornmerciai Ceiling Unit • T -Bar Ceiling Installation • Model #2024,2036,2048,2060,2072 NOT LESS THAN 2` • NtMINAL WIDTH, ( 1 1/2' ) NUT LESS THAN 3` NOMINAL THICKNESS (2 l/2 ' ) ( DEPTH DR: SIDE II VERTICAL MEMBER ) TU -UK Ii.A FIRE DEPARTMENT Please Gall 206-575-4407 End give this Fire Permit los i9 -S -ora - and exact address for shut- down or restoration approval. Without Cornments As Noted in Red Per The Attached Letter; I ; glans have been reviewed by The Tuley i( ...ntior: Bureau for conformance with curer► • s, :ards. Acceptance is subject to errors' d :. ":;`:.: :.,sons which do not authorize vio;ationif:< CNAd' yards ann orjinances. The responsibilty,S t taacy a design resp tow* 4/vItlh•(11Q dec;i9i Icons, deletions or revisions to thg$44tEE+# irk fifer':: .me. will voic! this cceptance . esubmittai of revised dra' Ings for subs ti.eilt apf�,rov t • Design per NFPA 13 — Ordinary Hazard - Restaurant All materials to be new, U.L. listed and F.M. approved All heads to be .at least 6' apart with n o obstructions Existing uprights to remain • 44 — Add Globe Model GL5651 Standard Response 155° Chrome Pendents %2 x %2 • 2 - Add 2 Globe GL5679 Standard Response 200° Dry Pendents % x1/2 (skirt -& sleeve) - • 1— Add Globe Model GL5661 Standard Response 175° Brass Upright'/2 x'/2 GaRTtF OF ? AMNOY rtmt PRCtYRC 70,}IRINKtAR 1::97 41091-t;4: .S ` �'; Gratin Firo Prn1c lr�OWNFr l: ; r ; REFLECTED CEILING PLAN 1/4" =11-0" JOSELITO & LOLITA SANTOS 16828 SOUTHCENTER PARKWAY TUKWILA, WASHINGTON 98188 ,7k7, V t. II. 411) __./_____________ 7°11 CO 4• , Corrugated stainless steel hose with stainless steel braid available in 2'. 3',4%5' 8 6' Iegnths • Elexheadornmerciai Ceiling Unit • T -Bar Ceiling Installation • Model #2024,2036,2048,2060,2072 NOT LESS THAN 2` • NtMINAL WIDTH, ( 1 1/2' ) NUT LESS THAN 3` NOMINAL THICKNESS (2 l/2 ' ) ( DEPTH DR: SIDE II VERTICAL MEMBER ) TU -UK Ii.A FIRE DEPARTMENT Please Gall 206-575-4407 End give this Fire Permit los i9 -S -ora - and exact address for shut- down or restoration approval. Without Cornments As Noted in Red Per The Attached Letter; I ; glans have been reviewed by The Tuley i( ...ntior: Bureau for conformance with curer► • s, :ards. Acceptance is subject to errors' d :. ":;`:.: :.,sons which do not authorize vio;ationif:< CNAd' yards ann orjinances. The responsibilty,S t taacy a design resp tow* 4/vItlh•(11Q dec;i9i Icons, deletions or revisions to thg$44tEE+# irk fifer':: .me. will voic! this cceptance . esubmittai of revised dra' Ings for subs ti.eilt apf�,rov t • Design per NFPA 13 — Ordinary Hazard - Restaurant All materials to be new, U.L. listed and F.M. approved All heads to be .at least 6' apart with n o obstructions Existing uprights to remain • 44 — Add Globe Model GL5651 Standard Response 155° Chrome Pendents %2 x %2 • 2 - Add 2 Globe GL5679 Standard Response 200° Dry Pendents % x1/2 (skirt -& sleeve) - • 1— Add Globe Model GL5661 Standard Response 175° Brass Upright'/2 x'/2 GaRTtF OF ? AMNOY rtmt PRCtYRC 70,}IRINKtAR 1::97 41091-t;4: .S ` �'; Gratin Firo Prn1c lr�OWNFr l: ; r ; REFLECTED CEILING PLAN 1/4" =11-0" JOSELITO & LOLITA SANTOS 16828 SOUTHCENTER PARKWAY TUKWILA, WASHINGTON 98188 ,7k7,