HomeMy WebLinkAboutPP - 1000 ANDOVER PARK WEST - NORDSTROM - PERMITS AND PLANS1000 ANDOVER PARK WEST ASSOCIATED PERMITS 16-F-244 07-F-011 SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Site Address: 1000 Andover Park West Tenant Name: **PLEASE PRINT** Nordstrom Quality Center ANDOVER WEST LLC Property Owner's Name: 2623049118 Parcel King Co. Assessor's Tax No.: 262304911809 Suite Number: Floor: New Tenant? ❑ - Yes [k- No Mailing Address: PO ROX 97070 KIRKI AND WA 98083 City State Zip CONTACT PERSON -if there are questions about the submittal. Name: Bryan Davis Day Telephone: 253-398-1052 Company Name: Protection 1 Mailing Address: 22026 68th Ave S Kent WA 98032 City State Zip E-mail Address: bryandavis (@protection 1.com Fax Number: Contractor's City of Tukwila NICET III number: Ben Alban 106654 Business License number: 04-398 Total number of new/relocated devices or sprinkler heads: 2 Valuation of Project (contractor's bid price): $ 250 Scope of Work (please provide detailed information): Move 2 horn/strobes due to construction. PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Date: 11/2/16 Print Name: Bryan Davis Day Telephone: 206-437-1938 Plan Permit App.doc 8/22/14 TFD FP Form 8 INSPECTION RECORD Retain a copy with p - oa INSPECTION NUMBER FEB 2007 F Oil PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: 4o¢.DSJia M 61/C.., Type of Ins : Address: l 0 00 A-tAv.1 Suite #:aZriW{ Contact Person: Special Instructions: Phone No.: ZG 3 - ZS -- lf 13 $ 54 Approved per applicable codes. Corrections required prior to approval. COMMENTS: FA "F;14/41. 0 K._ CPA -,4e sw a -P vvrJ P -r) Paovv . S.Lfot -tS 4T. Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: /s Z Date: 1131 k i- Hrs.: 1 $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from e City of Tukwila Finance Department. Call to schedule a reinspection. Word/Inspection Record Form.Doc 1/13/06 T.F, D. Form F.P. 113 TUKWILA FIRE PREVENTION BUREAU 444 Andover Park East, Tukwila, WA 98188 - Phone 206-575-4407 - Fax 206-575-4439 E-mail: tukfdprv@ci.tukwila.wa.us CONTRACTORS MATERIAL AND TEST CERTIFICATE FIRE ALARM AND FIRE DETECTION SYSTEMS Fire alarm System is ready for Fire Department acceptance testing. Failure of test will result in termination of the testing and additional fees will be assessed. Contractor is responsible for supplying manpower for Final Acceptance Test with two-way communications. • Date I 49/07 Permit # Property Address /ace Ahaewer ,?Plc U/ City Tukwila / Zip Code Name of Facility 44prc /sL rOw2 Qua/ t y Ceti ?et' Occupied as . Suite # 98189 Owner or Representative Phone # Installing Company Ci Loci' /20/47., i Sec' ,-1"f y Installing Contractor's Address Rea UiPiottel 6'i/'l& . City Chet /Acre h 4 Phone # ga9,66.9 e14' J Installer's Name (PRINT) 7 fl?i.q S rl/el� License and/or Certificate f ! t'j . - 9095- General Contractor Electrical Contractor FACP Equipment Manufacturer Model# 70)4f This system has been installed, pre -tested and operates in accordance with the standards listed below and was inspected by .TPI^RI+z SIrii/y On (date) //19h7 and includes the devices listed on back. Circle ail that apply: NFPA 72, Chapter 12 4 5 6 7 and/or IFC SEC 907 NFPA 70, National Electrical Code, Article 760 Manufacturer's Instructions )( Manufacturer's Instructions Other (specify) Tukwila City Ordinance Numbers 2050, 2051 UL Central Sta ' onitor T/� / System is monitored by C C/( p0/l1 SIGNED z J Date / hole7 System Fi ware: Installed version . • Checksum Date Initial program Installation 11/90) Date Revisions and Reasons EQUIPMENT INSTALLED AND TESTED: Control -Panel Manual Station Smoke Detectors Heat Detectors Duct Detectors 1 of Jof a (AIL 2_0f2_ AN Devices , of Audio Devices of Visual Devices of Auto Door Release of Trouble Indictors of - Batteries • Make/Model Make/Model Make/Iviodel. Make/Model Make/Model 7C • gc, Boilt f ysyekh re hlrf(4 fys1ei jeiis,L-,--- Mak!Mde1 Make/Model Make/Model ‘, Make/Model Readings Battery Fun Load Charge :2 Generator of Make/Model HVAC Controls of Make/Model .:\ ., ,• Fire Alarm Dialer J_ of J_ Make/Model .134 7024( cited- itp4Luc'' 5fc tii.i. y " Monitored by Annunciator cif - Make/Model gPf4 , Sprinkler System. (Fire Alarm connections only) , Water Flow Sw 4 of 6 Make/Model l'er4Ces-- Valve Tamper Sw. 4 of 9 MakefModel PTV ) of / Make/Model SyYte Elec. Alarm Bell of • Make/Model Automatic time Delay of Water Flow Alarm. 41 seeendit. Nene b:kstglied Do you meet audible/visible requirements of WAC 51-20, IFC SEC 907., and/or NITA 72 Cuter 6? Yes No X Test of alarm System on emergency power, satisfactory? Yes No Test Witnessed by 5Qte_ Zelade,"- Title rece Comments: Date 1,Asile 7 ‘, • lnhRIflil TPD FP Form #110 FIRE WATCH REQUIRED Due to the inoperative fire protection system(s) in your facility, you are required to provide a fire watch per City of Tukwila Ordinance #2437, section 16.40.120-D and Ordinance#2436, section 16.42.100-C (see reverse side). The fire watch shall be maintained until the system(s) are operational as determined by the Tukwila Fire Marshal's Office. FAX paperwork to 206-575-4439 to verify the completion of repair work and/or the restoration of system monitoring, in order to end the fire watch. The fire watch is required 24 hours a day. Designated employees may serve as the fire watch during business hours, while performing their regular job. Fire watch personnel must be aware of, and accept the duties of the fire watch. After hours fire watch personnel niust be on location and must patrol the building following the close of business. Every two hours they must call 206-971-8737 and leave a message stating the following: 1. Your name. 2. Street address of firewatch location. 3. Time of day. 4. If everything is OK, state all clear. If you discover an emergency during your patrol , call 9-1-1 immediately to report it. Date: ARA /4 r Inspectors: Reason For Fire watch: A'/ r Std Start time: 'I/O' Z%4142- �t hG Incident #: Business Name: Ala 1213 $Y o st itlaittowt Business Address: / "O 4ce-00Pg, A Business Phone: a 2Z, ..Zr3 y 3 9 Person in Charge: Signature: D j i-1 8-TEWelt W — Fire Marshal's Office Y — Owner/Manager Rev. 7/29/14 T.F.D. Form F.P. 41 z-/ y.: .J -/5e Fire Marshal's Office • Phone: 206-575-4407 • Fax: 206-575-4439 • Email: FireMarshaa?tukwilawa.gov rdkle44,0 GENERAL NOTES 1. A DIGITAL ALARM COMMUNICATOR TRANSMITTER (DACT) NFPA 72 SEC 28.8.3.2.1. IF THE TRANSMITTER IS NOT LOCATED IN THE SAME ROOM AS THE TELCO EQUIPMENT BACKBOARD FIRE WIRE IS TO BE USED BETWEEN THE "D" MARK AND THE FIRE ALARM CONTROL PANEL EXCEPTION, IF CONDUIT IS PROVIDED FROM TELCO BACK BOARD TO TRANSMITTER LOCATION STAN- DARD I/O WIRE MAY BE USED. 2. DACTS MUST BE CONNECTED UPSTREAM OF ANY PRIVATE TELEPHONE SYSTEM AT THE PREMISES. CONNECTION MUST BE MADE AT LOOP START. TELEPHONE CIRCUIT. 3. FAILURE OF EITHER TELEPHONE LINES MUST BE ANNUNCIATED LOCALLY AND TRANSMITTED WITHIN FOUR MINUTES OVER THE SECOND LINE (SEC. 26.6.3.2,1.4) 4. IF LONG DISTANCE IS USED, THE SECOND NUMBER SHALL BE A DIFFERENT CARRIER, WHERE AVAILABLE (SEC. 26.6.3.2.1.5(7)) 5. POWER LIMITED WIRING SHALL BE SEPARATED FROM NON -POWER LIMITED ELECTRIC LIGHT, AND CLASS 1 CIRCUITS. A MINIMUM OF 2 INCHES. 8. THE ELECTRICAL CONTRACTOR WILL PROVIDE A 120 V.A.C. 20 AMPS DEDI- CATED CIRCUIT TO LOCATION OF FIRE CONTROL PANEL/TRANSPONDER WITH A LOCK -ON TYP. C.B. 7. CONSULT WITH OWNER AND/OR GENERAL CONTRACTOR FOR EXACT LOCA- TION OF THE FIRE CONTROL PANEL/TRANSPONDER PRIOR TO INSTALLATION. 8. INSTALLER SHALL COORDINATE ALL WORK WITH THE OWNER & GENERAL CONTRACTOR AND ALL OTHER TRADES. ADDITIONAL NOTES 1. ABOVE GROUND WATER SUPPLY DETECTOR CHECK TAMPER SHALL CAUSE A SUPERVISORY SIGNAL AT THE PANEL AND THE CENTRAL STATION. 2. FIRE CONTROL PANEL/DACT IS INHERENTLY POWER LIMITED AND SIGNA- LING AND CARRIER, WHERE AVAILABLE (SEC. 28.6.3.2.1.5(7)) 3. A COMPLETE PRE-TEST PRINT OUT FROM THE CENTRAL STATION SHALL BE PRESENTED TO THE INSPECTING FIRE OFFICIAL PRIOR TO THE START OF THE INSPECTION. 4. CIRCUIT DISCONNECTING MEANS SHALL HAVE A RED MARKING,SHALL BE ACCESSIBLE ONLY TO AUTHORIZED PERSONNEL, AND SHALL BIDENTIFIED AS "FIRE ALARM CIRCUIT". PER SECTION 10.6.5,2,1 -10.6.5.2.4 5. LOOP RESISTANCE AND STRAY VOLTAGE TEST RESULTS WILL BE PROVIDED TO THE FIRE OFFICIAL UPON ALARM FINAL INSPECTION, THE RESULTS WILL BE ON COMPANY LETTERHEAD,WILL STATE THE TIME, LOCATION, SERIAL NUMBERS OF METER USED, CALIBRATION DOCUMENTATION, NAME OF TECHNICIAN,AND WILL BE "WET SIGNED" (IN ACCORDANCE WITH NFPA 72. 2013 CHAPTR 14). 6. A COPY OF THE RECORD OF COMPLETION SHALL BE PRESENTED TO THE FIRE DEPARTMENT OFFICIAL AND THE ORIGINAL SHALL STAY WITH THE SYSTEM. 7. MOUNTING OF ALL DEVICES TO COMPLY WITH NFPA 72. REFER TO MANUF- ACTURER'S CUT SHEETS FOR MORE INFORMATION ON THE DEVICES. 8. A SEPERATE CABINET / ENCLOSURE(�SHALL BE PROVIDED AND MARKED "SHALL ALARM D IN THE ENC OSURE)).. LOCATED NEAR FACP. PLANS 9. FIRE ALARM CONTROL PANEL SHALL BE LOCATED IN AN ENVIRONMENTALLY CONTROLED, CLEAN & FREE OF DEBRIS ROOM. CONTROL PANEL FOR FIRE ALARM ONLY. 10. ALL WIRING AND CABLING METHODS WILL COMPLY WITH N.F.P.A. 70:780-28 STANDARDS. BY WAY OF PROTECTING ALL WIRING WITHIN 7 FEET FROM THE FINISHED FLOOR IN CONDUIT STUB -UP AND BY CONCEALING ALL WIRING IN WALLS, CEILING AND PROTECTIVE BUILDING ELEMENTS. 11. NO "T" TAPPING OF FIELD WIRING IS PERMISSIBLE IN SUPERVISED CIRCUITS, DATA CIRCUITS ARE EXCLUDED. D Without Comments As Noted in Re;'1 • Per The Attaches Letter These plans have been reviewed by fne Tukwila Fire PreventionBureau fer conformance „t+} current City ';ndards. ACCepcE tG iS ''ubjeCt t o e ro s and „nissions which do nOk },'`horiZe viol t}0ft of adopted ;;dards and terra :-nce, she resfa, is rriIky for the .o quacy of deslc,.i ' esi totalis Wit) the designer. 4ditions, deletions 0t :evisiofs to trlrAs drawings after this date will ‘froid tr , • cceptance ariri W li require a resubmitta{ of _ '-1se' drawings for yu eqi ent approval. Final acceptance is » itject to field tt t and inspection by The Tukvvila Fire Prevention Bureau, Date: 11 -tel" lc By: AVs1( NORDSTROM 1000 Andover Park West Tukwila, WA 98188 • SEQUENCE OF OPERATION cn g AREA SMOKE DETECTOR MANUAL FIRE ALARM BOX WATER FLOW SWITCH VALVE TAMPER SWITCH DUCT SMOKE DETECTOR HVAC FAN EMERGENCY GENERATOR RUNNING EMERGENCY GENERATOR TROUBLE POWER SUPPLY TROUBLE COMMON SYSTEM TROUBLE INDICATE ALARM ® FACUTANNUNCIATOR X X X § INDICATE TROUBLE fp FACU/ANNUNCIATOR 39.482 1 a1 X X INDICATE SUPERVISORY ® FACU/ANNUNCIATOR X X X X ACTIVATE OCCUPANT NOTIFICATION X X X ACTIVATE SMOKE PURGE SYSTEM X X X RECALL ELEVATOR TO DESIGNATED LEVEL RECALL ELEVATOR TO ALTERNATE LEVEL SHUTDOWN ELEVATOR POWER FLASH WARNING LAMP IN ASSOCIATED ELEVATOR CAR SHUT-OFF ASSOCIATED FAN X SHUT-OFF MUSIC SYSTEM(8) X X X TRANSMIT OFF-SITE ALARM X X X TRANSMIT OFF-SITE TROUBLE X X TRANSMIT OFF-SITE SUPERVISORY X X X X NOTES: 1. GENERAL. TROUBLE INCLUDES POWER FAILURE, OPENS OR SHORTS ON SIGNALING LINE OR NOTIFICATION APPLIANCE CIRCUITS AND SYSTEM GROUND FAULTS, 2. PASSENGER ELEVATOR MACHINE ROOM I8 LOCATED ON THE ROOF, DESIGNATED LEVEL 18 FIRST FLOOR, ALTERNATE LEVEL I8 SECOND FLOOR. MACHINE ROOM DETECTOR RECALLS ELEVATOR TO DESIGNATED LEVEL. 3. FREIGHT ELEVATOR MACHINE ROOM 18 LOCATED ON THE SECOND FLOOR, DESIGNATED LEVEL 18 FIRST FLOOR, ALTERNATE LEVEL 18 SECOND FLOOR, MACHINE ROOM DETECTOR RECALLS ELEVATOR TO DESIGNATED LEVEL, p. s s, r _ 4.a..y.'g C.. �y (like IEI') S %� a33lE7E. O■ ce F -',`V` and exact t dry:, ess for shut- Jown or restoration approval. PROJECT INFORMATION PROJECT INFORMATION: NAME OF PROJECT: ADDRESS: PROPOSED USE: FIRE ALARM INSTALLER: PROTECTION 1 22028 88TH Avenue South, Kent, WA 98032.1939 PHONE: 253.398.1081 FAX: 253-872-4419 STATE LICENSE No.'s PROTE0022K2, PROTEOAO33BP & UB1801354928 FIRE ALARM VENDOR PROTECTION 1 4221 W JOHN CARPENTER FWY IRVING, TX 75087 877-357-1808 FIRE ALARM DESIGNER BENJAMIN B. ALBAN, ET NICET III # 108854 4221PROTECTIJOHN CARPENTER FWY IRVING, TX 75067 NORDSTROM 1000 Andover Park West Tukwila, WA 98188 OFFICE / WAREHOUSE CENTRAL STATION LISTING CCN File No. Vol. No. UUFX S2684 20 214-277-7111 CODE SUMMARY • SCOPE OF WORK THIS PROJECT RELOCATION OF THREE (3) HORN STROBES DUE TO THE REMOVAL OF WALLS WITHIN AN EXISTING STRUCTURE. THE SYSTEM SHALL BE MONITORED BY AN APPROVED LISTED CENTRAL STATION. • APPLICABLE BUILDING CODES BUILDING FIRE ELECTRICAL NFPA 72 ACCESSIBILITY STATE OTHER 2012 IBC cn g 2012 IFC 2014 NFpA 70 2013 EDITION 0 38,371 122 • OCCUPANCY CLASSIFICATION B / S-1 • OCCUPANCY USE OFFICE / WAREHOUSE • GENERAL OCCUPANT LOAD OF AREAS BUSINESS STORAGE RESTROOMS TOTAL (SQ.FT.) INDEX OF DRAWINGS • FA -0 • FA -1 TITLE SHEET, GENERAL NOTES FIRE ALARM LAYOUT FIRE ALARM RISER DIAGRAM & SYSTEM CALCULATIONS ce O U E 0 0 0 0 er Park West 0 0 0 CO CO Tukwila, WA 9 REVISIONS z\ 01101101011104.11.1110 No. DESCRIPTION DATE SCALE AS NOTED JOB No. T.B.D. DRAWN BY BENJAMIN 8. ALBAN, ET DATE 10.20,18 NICET LEVEL III 0108864 THIS DRAWINO IS AN INSTRUMENT OF SERVICE AND THE PROPERTY OF PROTECTION ONE ALARM MONITORING INC, THIS DRAWING MAY NOT BE REPRODUCED, OR REPRODUCTIONS HEREOF UBED, WITHOUT THEIR WRITTEN PERMISSION, PAM NOV 10 2016 TUKWILA FIRE /.2022 SHEET TITLE FIRE ALARM MONITORING SYSTEM REMODEL - TITLE SHEET SHEET NO. FA -0 1 OF 2 1 AREA (sct.F r.) 1 300 F/PP 1 CCC LOAD CALL 0 38,371 122 237 F/PP 0 9 § 39.482 1 a1 INDEX OF DRAWINGS • FA -0 • FA -1 TITLE SHEET, GENERAL NOTES FIRE ALARM LAYOUT FIRE ALARM RISER DIAGRAM & SYSTEM CALCULATIONS ce O U E 0 0 0 0 er Park West 0 0 0 CO CO Tukwila, WA 9 REVISIONS z\ 01101101011104.11.1110 No. DESCRIPTION DATE SCALE AS NOTED JOB No. T.B.D. DRAWN BY BENJAMIN 8. ALBAN, ET DATE 10.20,18 NICET LEVEL III 0108864 THIS DRAWINO IS AN INSTRUMENT OF SERVICE AND THE PROPERTY OF PROTECTION ONE ALARM MONITORING INC, THIS DRAWING MAY NOT BE REPRODUCED, OR REPRODUCTIONS HEREOF UBED, WITHOUT THEIR WRITTEN PERMISSION, PAM NOV 10 2016 TUKWILA FIRE /.2022 SHEET TITLE FIRE ALARM MONITORING SYSTEM REMODEL - TITLE SHEET SHEET NO. FA -0 1 OF 2 Firelite MS-96000DLS P Address: State NORDSTROM #323 1000 ANDOVER PARK WEST TUKWILA WA STANDBY ALARM QtJANTTTY Device EACH 1 TOTAL EACH TOTAL Fre Alarm Control Panel 1 M8.9600LCL8 ANN•80 0.120000 0.120000 0.170 0.170000 0.016000 0.015000 0.040000 0.040000 0. 00 0.000000 0.000000 0.000000 BG.12Lir STA 0.000230 0,000690 0.000300 0,210000 0.000900 0 7 0.000300 0.( 0.000300 0.000000 0.019800 0.000300 0.000300 0.000400 0.000300 0.000000 0.002800 0.000300 Ctcu4 # 1 0,000000 1.080000 0.00400 1,080000 1 #2 0.000000 1.060000 1,060000 3 0.000000 1.060000 1.080000 1 Qrcut # 4 0.000000 1.046000 1.048000 qt Total stand by current X Stand by hours Stand by arrpThours 4,228000 Total Alarm Current X elarm Mnutes (5)/60_ Alarm Total amp/hours Total Amp/hours X Derating factor of 20% Minimum Battery Size 4.10 12 4.9r 4.44 0.083 0.37 Batiery S AMP HOUR A PANEL BATTERY CALC N.T,S. FA -2 ItML ITL M&82000DLS UL derated Protection SECURITY SOLUTIONS Rev. 64444 m)m RIM MARE PANE. Total De Moo Standby AM 106. OHMSI Length 1000 ft (Feet) 2; 400 Actual Volta (I Voltage OHMS LOL Drop% 7.37% 1 Id 400 2000 LS • Total Current Total II tem Standby torsi ttlnt•m A►arSJ 0.116 2.76 0.31 red Recomm.ndtd AIH Battery" 3.71 6.1'1 3.6B2 TOTAL BACKUP 18 Amp Hours 0 �7T3�1�;I'-�TP�T,TT_��:TT:];I�i7T•i'=7�it+1 . 1 0 � • 144.9115iTTl';Tr ifi:rr-z. l c•11 TI NAC 1 CIRCUIT BATTERY CALC .T.S. FA-2 CE N-47 15CD 0 N-1 ;0: N-1.2 N-1.1 1100• 110CD 110CD N•2-3 N•2.2 N- 110CD 110CD 110CD N•4-2 N 110CD 11000 ;o: WOOD SHOP DUST COLLECTION ROOM TOOL ROOM - J r -I L J SANTA LANE/ HOLIDAY STORAGE 1 L J II I II II II II II 11 I1 1- - I- -I II 1 1 I I I 1 11 I1 11 11 11 11 L _J L _J 11 1I 11 11 11 r -1r--1 I I I I I I I I L J L J ✓ 1 L J ✓ 1 L J II I i I I I I I I I I I i _ L I I I I I I I I I I I I I I 1 1 F--ih- -I 11 I1 I1 11 11 1 I 1I I1 I1 11 L J L J 11 I1 11 1 1I 1 111 -1 1I II L J L J 11 II 1 1 11 11 11 11 11 I1 F -I I I 1I I1 1I 11 I 1 1 I 1 1 1 1 1 I 11 L J L _J I1 11 11 11 II ✓ -I r-1 I I I I I I I I L _J LJ II II II II J L II II II II II - 1 r II 1 J L -1 J J F L L 11 11 I1 11 JL I II II 11 -IF 11 II II I1 II II II II II II _J L II II II II II - 1 r II II J L 1 11 11 11 11 1 1I_ _I 11 11 11 11 11 1--1!- 11 11 11 11 II L II _J L II II 11 FLAME ROOM 1 I I I _I _ II II II II II -1F- 11 1I II II II II II II II II J L II II II II II -1 r II II _J L WAREHOUSE L l •V► 8 BEING REMOVED T ORRN 81NAL 0 r I _ HI ORN/ II II I IM E PAINT B OT II II II L _J L J II II I I I 1 I I r-Ir� FLOOR PLAN SCALE: 1113" • 1%0" r -1 r I1 I 11 1 II I I 1 1I1 I II 11 11 I 11 11 11 I I I I 1 r l 11 I II I L J 1 II 1 II I II 1 II 1 11 1- -t r -1 II I II I RESETTABLE POWER 01 t.I.I.It•Im1 NONREBEITABLB POWER 01 REMOTE ANNUNCIATOR NON REBETTABLE P EIA -232 T B 3 9CA DD CSS®®T 7 4 5 NOo NO NO NO NCO 6 T9919, GC7®c� T©�r�®'sK1.Td' BXCR I 100 BB/,�I(BAAB 7 V R D N N T T 70120VAC DED, CKT. BREAKER EARTH GROUND I r c MENS o. NNNEWRR "°IT117 E ORIGINAL HM511913 E v` K OFFICE a/ ROBE I N QFFIC HORN1B LO OFFICE ONBE o0 00 01 1 10 0 1 ,0 o c� I0 E .P. EEEN23 ED MEM MOO avDMOO 6 ti +'- J o TO CENTRAL MONTORNG FACIUTY, VIA LOCAL TRLCO DIAL NIIW011t a LOOP START UNI PRaMARY I ® OND 5 0.E ea /NLD • RN 0.h PH1 PH2 OONNDTM FgeM •24V V0t111l DOM WA. 0001/11410117/10Rp UDACT QPowin ❑CONU. FIA I !t 4E! ❑MI8s0/F CLEAR TEST MODE UDACT•F 12vdc 18AH BATTERY 0 0 12vdc 18AH BATTERY SYSTEM RISER I N.T.S. FA -1 FIRE ALARM EQUIPMENT LIST SYMBOL MFG. QTY PART NO, DESCRIPTION FACP FIRE -LITE UNIVERSAL POWER 1 2 MS-98800UDLS 11B12180 FIRE ALARM CONTROL PANEL 18AH 12V SEALED LEAD ACID BATTERY FSA FIRE -LITE 1 ANN -80F REMOTE LCD ANNUNCIATOR KEYPAD I r 1E FIRE -LITE 3 BG-12LX ADDRESSABLE MANUAL PULL STATION OE FIRE -LITE 1 SD -355 ADDRESSABLE SMOKE DETECTOR IM FIRE -LITE 7 MMF-300 ADDRESSABLE MONITOR MODULE SYSTEM SENSOR 19 P2W INTERIOR HORN/STROBE, WHITE :q: SYSTEM SENSOR 3 SW INTERIOR STROBE, WHITE A HONEYWELL LOT 4607 4 COND 18AWG FPLP NON SHEILOED WIRE 4,01 11N8A��'! cars B HONEYWELL LOT 4607 41Q�V1 3 I�I�N SHEISBEIb 1_) HONEYWELL LOT 4516 CCOt D 91IC L W��E(CLA£S'B1) NOTIFICATION CIRCUITSF(CLASS 'SI EXISTING DEVICES POTTER 1 VSF-R WATERFLOW (P.B4O,) POTTER 1 RBVM-1 SUPERVISORY SWITCH (B -FLY) (P,B4O,) 0 POTTER 1 P510 PRESSURE SWITCH (P,B.O.) `,cJ- SYSTEM SENSOR 3 D4120 DUCT SMOKE DETECTOR ce O z 0 03 O co '6 It .6. O 00 co IVA REVISIONS MINIMOMOMINNO No, DESCRIPTION DATE SCALE AS NOTED JOB No, T.D.D. DATE 10,20.16 DRAWN BY BENJAMIN B. ALBAN, ET MET LEVEL III #108884 THIS DRAWING 18 AN INSTRUMENT OF SERVICE AND THE PROPERTY OF PROTECTION ONE ALARM MONITORING INC. THIS DRAWING MAY NOT BE REPRODUCED, OR REPRODUCTIONS HEREOF USED, WITHOUT THEIR WRITTEN PERMISSION. SHEET TITLE FIRE ALARM MONITORING SYSTEM REMODEL - FLOOR PLAN SHEET NO, FA -1 20F2