Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PP - 1051 ANDOVER PARK WEST - RELIABLE PARTS - PERMITS AND PLANS
1051 ANDOVER PARK WEST ASSOCIATED PERMITS 14-F-214 06-F-123 16-S-012 93-S-194 B93-0345 B93-0286 D15-0182 D03-119 PWOS-065 SITE LOCATION 1051 Andover Park W Site Address: Suite Number: Floor: ReliableParts Tenant Name: New Tenant? CI- Yes Q - No Property Owner's Name:ReliableParts 1051 Andover Park W, TUKWILA, WA 98188 Mailing Address: City State Zip CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 t Illtl 1.41111 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.:2623049122 CONTACT PERSON -if there are questions about the submittal. Wendy Coile/ Jennifer Covello 253-620-5971 Name: Day Telephone: Company Name:TYCO INTEGRATED SECURITY LLC 11824 NORTH CREEK PKWY N # 105, BOTHELL WA 98011 Mailing Address: wcoile@tyco.com /Jennifer@nwpermit.com City State Zip E-mail Address: Fax Number:888-400-0383 Valuation of Project (contractor's bid price): $ Replace Fire Alarm Panel, install Annunciator, Communicator, Scope of Work (please provide detailed information): smoke detector, pull station. Also replacing burg. alarm panel, keypad, siren, and communicator. PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTII Plan Permit App.doc Date: 2/1 Day Telephone:206-774-9499 5/14/10 TFD FP Form 8 SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** n King Co. Assessor's Tax No.: 2.€2.€02.l' 1,04- 1 t2.2_ 5 Site Address: to 1 I� JV L f� Y'MUi- V.1 Suite Number: Floor: l 6 F1. Tenant Name: V- 93 (.e_. PA. -9,-(S New Tenant? ❑ - Yes [*, No Property Owner's Name: W- 'Ccs �u>t LA t L L C Mailing Address: lvs� M)oweat— Prkaac- c . City 18465 State Zip CONTACT PERSON -if there are questions about the submittal. Q / Name: \�h�(E_ L 1_6 Day Telephone: i� l % -o040 Company Name: LS la Mailing Address: C 5 Z4- TL . 1:r- 47 ID Z St), 4 _ g83Ra City State Zip E-mail Address: PAM- (c i1C- AWG, COLA. Fax Number:C/519 Ze. (033 Contractor's City of Tukwila Business License number: +j OS — ©q'( J Total number of new/relocated devices or sprinkler heads: f Valuation of Project (contractor's bid price): $ W k3 Scope of Work (please provide detailed information): AX'P MO o CA -TC— '(-t V (Gta-€fl6 PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AIJTHORIZED'AGENT: Signature Print Name: .."1:)A,-\/ 1 T>L ! 5 IC Plan Permit App.doc Date: 5 16 Day Telephone:(ZS �) SZ.‘ -- 0 09 8/22/14 TFD FP Foam 8 FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Reliable Parts 1051 Andover Park West Permit No.: 16-S-012 Date: January 26, 2016 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods Tess than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 1/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-05, section 13.5.6.2.2. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • All interior control valves shall be readily accessible, labeled and located not more than 6 ft. above the floor. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems, in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2013 Edition. INSPECTION NUMBER INSPECTION RECOR Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project:1 I a I I -C pip).5Typeof Inspection: (�J Address: /(15 - perp Suite #: Contact Person: Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: S� cl,)40C_ OK_ o)o 6,1,1491,vs frL r!iq-d A -oil- 40C r c-1-4‹ o -r 5Q e{ Needs Shift Inspection: Date: t //o// 6 Sprinklers: • Fire Alarm: Hood & Duca Monitor: Pre -Fire: Permits: • Occupalncy. Type: Inspector: _5701-- Date: t //o// 6 Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION NUMBER NSPECTION RECORD Retain a copy with per ' a 0 U, PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Proje f ,e1 ic�,Ie- kr Type of Inspection: 0�6/r .4e€J (%iL✓e F r<- r---,--iAddress: Suite #: 1 0 5 1 /1 pW Contact Person: Special Instructions: Monitor: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Needs Shift Inspection: /V //I-- Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Ans lector: A(5 ero Date: fiz,--Lid‘.1 Hrs.: , $80.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be al t 444 Andover Park East. Call to schedule reinspection. Receipt No.: Date: Word/Inspection Record Form.Doc 12/2/05 T.F.D. Form F.P. 85 1 INSPECTION NUMBER a/INSPECTION RECORD Retain a copy with per it L 3 2006 OG - /23 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project:, 441,E ani_ -s Type of Inspection: -vii8 VvTwte_s Address: /d 51 Suite #: A p Id Contact Persf� : r 7 /(96" Special Instructions: Occupancy Type: Phone No.: &is) 864— /zzl Approved per applicable codes. Corrections required prior to approval. COMMENTS: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: 4(4 igi Date: -4./3,0 Jo 6, Hrs.: n $80.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 444 Andover Park East. Call to schedule reinspection. Receipt No.: Date: Word/Inspection Record Form.Doc 12/2/05 T.F.D. Form F.P. 85 City of Tukwila Fire Department TUKWILA FIRE DEPARTMENT FINAL APPROVAL. FORM Project Name Re14bfee AW//7K 171C, MAY 2 9 2003 Steven M. Mul et, Mayor Thomas P. Keefe, Fire Chief Permit No . ('-'..) f Address /057 AelLAM/. Pk • to. Suite # (/ 'Retain current inspection schedule Needs shift inspection /Approved without correction notice Approved with correction notice issued Sprinklers: t/' Fire Alarm: Hood Duct: Halon: Monitor: Pre -Fire: Permits: Authorized Signature FINALAPP.FRM .512a/WV..3 Date Rev. 2/19/98 T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206-575-4404 • Fax: 206-575-4439 A City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188-7661 (206) 575-4404 TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM OCT 8 1993 Gary L. VanDusen, Mayor Control No. i ('?-� Permit No. Project Name Re 7.5 Address /0_31 A ti c(, i c.-(,) Suite # _ Retain current inspection schedule V !� Needs shift inspection x Approved without correction notice Approved with correction notice issued Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre -Fire: Permits: .4) ..S pie S+erosvr t ^y Authorized Signature Date FINALAPP.FRM T.F.D. Form F.P. 85 TUKWILA FIRE DEPARTMENT FIRE PREVENTION BUREAU . (206) 575-4407 CORRECTION NOTICE/REINSPECTION FEE BUSINESS NAME: 2t=//GLL?zi-/4A DATE: /0 S ADDRESS: /0S/ 4/76() BLDG: SUITE: TYPE OF INSPECTION: Slv1L" INSPECTOR: -57/0 BLDG. PERMIT #:(g92-0W- CONTACT :/g9_ &-- CONTACT PERSON: /.'e 1j m;/Af PHONE: Rf - //i ACTION REQUIRED: r?`vot.;de )(Vac sac e /G1e. regf LCe.G' * /0 ie Ze.) cu rf'ti //Yt.J 714Ar CORRECTION OF THE ABOVE ITEMS ARE REQUIRED BY: /.7A -/A 3 A $40.00 Reinspection Fee is required and must be received by the Tukwila Fire Department, 444 Andover Park East, Tukwila, Wa. 98188 prior to reinspection. Make checks payable to the City of Tukwila and provide the YELLOW copy of this notice with payment. FAILURE TO PAY the reinspection fee within seven 7'days may result in the issuance of a citation for Failure to Comply. For Office Use Only: Date Paid: Receipt #: File Code W -Finance Y -File P -Contractor THIP : CORREFEE . FRM T.F.D. Form F.P. 100 IFILIE FIRE PREVENTION BUREAU (206) 575-4407 CORRECTION NOTICE/REINSPECTION FEE TUKWILA FIRE DEPARTMENT BUSINESS NAME: ADDRESS: /067 LL OLE /,q,'75 OCT 2 1 1993 DATE;�-23 BLDG: SUITE: APT: TYPE OF INSPECTION: /-27 INSPECTOR:. /:1 BLDG. PERMIT #: CONTACT PERSON: /) ! //(-'6 / ` A (1f .- PHONE : ( 2S-' / 7 i ACTION REQUIRED: N Ai c) f} -JV c O71/t-f2 ie&Z.A7& " 4/t14 kr? syr . eq.> / km/y% 4 /) 6 09/704) /fri /eih2L" /r)cit ''/ » /.M/%• CORRECTION OF THE ABOVE ITEMS ARE REQUIRED BY: h2-75---3 A $40.00 Reinspection Fee is required and must be received by the Tukwila Fire Department, 444 Andover Park East, Tukwila, Wa. 98188 prior to reinspection. Make checks payable to the City of Tukwila and provide the YELLOW copy of this notice with payment. FAILURE TO PAY the reinspection fee within seven 7 days may result in the issuance of a citation for Failure to Comply. For Office Use Only: Date Paid: Receipt #: File Code: W -Finance Y -File P -Contractor WP:CORREFEE.FRM T.F.D. Form F.P. 100 City of Tukwila FIRE DEPARTMENT.. 444 Andover Park East Tukwila, Washington 98188-7661 (206) 575-4404 TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Control No j '3 -0286 Permit No. Project Name � A �` L� f .11.1 Address /0137/ i4 f'• Suite #_ Retain current inspection schedule Needs shift inspection Approved without correction notice Approved with correction notice issued Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Cv,24.77 .S v/c d'S Pre -Fire: __ Permits: Authorized gnature D7A-3 ate FINALAPP.FRM T.F.B. Form F.P.<85 IR R C ION FILE i 2004-A 48th AVENUE CT. E. TACOMA, WA 98424 FAX (206) b22-6150 TEL (206) 926-2290 LATE R/19/ fl TO TUMILA FIRE DEPT. ATTENTION G'I`rvF =Hug FROM MARGARET O'BRIEN FAX GQ,V,R SHEET RECI P I ENT' S FAX NO. 57 S 44 39 =VENTS Reliable Parts ---- 1051 Andover Park West Patriot Fire Protection will be plugging off the lov. ,Cites that feed the drops oily. A forrnal plan showing the work to; be radc)ed in the nev offices will be submittal for a perrnit:. The demo ',xwk will....kg_performed on tuesday 8/24/93. If you have any o-uestiols reclarclir JJ - ,s 12Iease fees free to call. Thank you, t Eoulan•e -O'Brien TUKWIU FIRE DEPARTMENT Please call: 575.4407 and give this b No. /l and exact address for shut- down or restoration approves NUMBER OF PAGES BEING SENT / SPOKANE. WA OFFICE FAX (509) 926-3708 TEL (5091 926-3428 PAT RIFPD 9CF VANCOUVER, WA OFFICE FAX (20E) 699-4485 TEL (206) 699-4403 FILE 1 SEATTLE FIRE DEPARTMENT c e -#, .2.2.61:40.5"Z CONFIDENCE TESIING Acct . * AUTOMATIC SPRINKLER SYSTEMS Address >D St Avpov6e. PARR W , 1 g.14)/4 ,/t 44 QJJ9 {: r Occupied as R EL 1A&L E I°Ae i s Building Owner hE6Ai Phone 57S: 4 771/ Address c5A!'7 City.. TteXtv,IiA Zip Code 91/11 Date of Inspection /Z,////yc Type of inspection: Annual AV Other Tester's Name (PLEASE PRINT) A2 Ai )e 47TS SFD Certification # sl.P 9997. fit.M: - Trip test (dry trip) conducted' Yes System tripped in seconds. 2. All f • switches, supervisory, switches and alrm • IIs tested* es 0 No 0 N/A 0 Static Pressu psi 3. Alarm belt operates. Yes ❑ No ❑ N/A ❑ 4. Flow tests conducted. Yes 0 . , No 0 Flow pressure: psi yEl -I ch drain? Yes 0 No 0 spected a ubricated • Yes 0 No 0 refills system in 30 minutes. s ❑ No ❑ ined and restored to normal operation Yes No.❑ e heat actuation devices tested on pre -action and deluge systems? Yes WET SYSTEM; 1. Flow test conducted' Yes [ No' ❑ Static pressure: i'15 psi Flow pressure: 130 psi 2 -inch drain? Yes No ❑ Other Ei 2. Flow switches, supervisory, switches and alarm bells, tested. Yes Ei No. 0 NIA 0 3. Alarm bell operates. Yes LJ No N/A 0 4. Systems inspected and lubricated. Yes /No ❑ N/A 0 5. Pressure regulating valves tested. Yes 0 No ❑ N/A (/ • uIQMaikSnrh *Ier Svstems;(conti ed): 1.. Central Station monitoring? Name of Company 4 t T Location of sprinklers: Basement Hallways As designed 7 Other . Pumper connections and Clapper valves unobstructed• 4. SpttnIder heads less than 50 years old Yes YE Yes [21/* o 0 5, Spare sprinkler heads are available 6.., Systems left.in service Valves are sealed or supervised Yes ENo D & Signs are provided on valves Yes,! 9. City ; static Water pressure 14 Jr psi Problems found: Air194/E Corrections made: Date corrected By THIS IS TO COMFY THAT THE AUTOMATIC SPRINKLER SYSTEM HAS BEEN PROPERLY TESTED AND INSPECTED FOR RELIABILITY TO COVER THE ITEMS LISTED IN THIS REPORT, IS CONSISTENT' ITH MANUFACTURER'S REQUIREMENTS, AND ALL CORRECTIONS HAVEBEEN MADE. qq SIGNATURE r., F TESTER Aj Agency: Aiki FIRE & SAFETY. 3013 3rd Ave. Nath. Sem. WA 98109 PHONE 284172 Scope Of Work Project Name: Reliable Parts 1051 Andover Park West Tukwila, WA 98188 For: Replace Fire Alarm Panel — Currently on Scan Alert Panel By: TYCO Integrated Security 19625 62th Ave S Kent, WA 98032 License ID '%yG0 I /S 72'b DO Contact: Ron Little Telephone: 425-275-7878 Fax: 253-796-7267 New Quantity Model Description 174c,t 1 MS-9050UD-A8 1 2 2 1 1 1 ANN -80-W MMF-301 477967 SD355 BG-12LX IPGSM-4G existing SCAN Alert line FireLite Addressable Fire Alarm Panel with Communicator ASSY, FNL ANNUNICATOR White Addressable Monitor Module Universal Power Group, 12V, 7AH Addressable Low Profile Smoke Detector Addressable Manual Pull Station IP/4G Communicator, Dual Primary UL — Replace Scope of Work: 1. Remove SCAN Alert panel. 2. Install new FIRE LITE addressable fire alarm panel. 3. Install annunicator at front entrance to office. 4. Install smoke detector over fire alarm panel and connect. 5. Install manual pull station next to fire alarm panel. 6. Install addressable monitor module and connect to existing water flow and tamper switches. 7. Install FIRELITE IP/4G communicator and connect to fire alarm panel transmitter. Replaces existing SCAN Alert line. 8. Test fire alarm device to ensure they are communicating to TYCO Integrated Security central station. 9. The fire alarm signals will communicate back to TYCO Integrated Security UL Central Station. 10. TYCO Integrated Security is responsible for the annual testing and servicing of the fire alarm equipment. , @)Ftre.uleAtarms by Honeywell MS-9050UD Battery Calculation Secondary Power Source Requirements Device Standby Current (amps) Secondary Alarm Current (amps) Qty Current Draw Total Qty Current Draw Total Main Circuit Board 1 x 0.120000 = 0.120000 1 x 0.200000 = 0.200000 4XTMF 0 x 0.005000 0 x 0.011000 EOLR-1 0 x 0.020000 0 x 0.020000 IPDACT-2 0 x 0.093000 0 x 0.136000 IPDACT-2UD 0 x 0.098000 0 x 0.155000 ANN -BUS Devices ANN -SEC Card 0 x 0.003000 0 x 0.003000 ANN -80(-W) 1 x 0.015000 0.015000 1 x 0.040000 0.040000 ANN-(R)LED 0 x 0.028000 0 x 0.068000 ANN-RLY 0 x 0.015000 0 x 0.075000 ANN -I/O 0 x 0.035000 0 x 0.200000 ANN -I/O LED 0 x 0.000000 0 x 0.010000 ANN-S/PG 0 x 0.045000 0 x 0.045000 ANN -LC 0 x 0.150000 0 x 0.150000 Addressable Devices BEAM355 BEAM355S BEAM 1224 CP355 SD355 SD355T AD355 H355 H355R H355HT D350P D35ORP D350PL D35ORPL D355PL MMF-300 0 x 0 x 0 0 0.002000 0.002000 x 0.017000 = x 0.000300 MMF-300-10 MDF -300 MMF-301 MMF-302 MMF-302-6 BG-12LX CMF -300 CMF -300-6 CRF -300 CRF -300-6 CDRM-300 0 0 0 0 0 0 0 0 0 0 0 0 2 0 0 1 0 0 0 0 0.000300 0.000300 0.000300 0.000300 0.000300 0.000300 0.000300 0.000300 0.000300 0.000400 0.003500 0.000750 0.000375 0.000270 0.002000 0.000230 0.000390 0.002250 0.000270 0.001450 0 x 0.001300 = 1300 0 x 0.000400 = B501 BH -2 B501 BHT -2 B200SR Fire -Lite Alarms 0 x 0.001000 = 0 x 0.001000 = 0 x 0.001000 = 0.000750 0.000230 Page 1 8/4/2014 B224RB B224BI 0 0 x x 0.000500 0.000450 Maximum alarm draw for all Addressable devices ----------> 0.40000 Resettable Power 4 -Wire Smoke Detectors 1 0 1x1 0.000000 1=1 1 0 Ix 0.000000 1=1 Auxiliary Power CMF -300 (Aux. Power) 0 x 0.001700 0 x 0.007000 CMF -300-6 (Aux. Power) 0 x 0.008000 0 x 0.020000 MMF-302 (Aux. Power) 0 x 0.012000 0 x 0.090000 MMF-302-6 (Aux. Power) 0 x 0.050000 0 x 0.270000 B200SR (Aux. Power) 0 x 0.000500 0 x 0.035000 Miscellaneous Devices 0 x 0.000000 0 x 0.000000 0 x 0.000000 0 x 0.000000 0 x 0.000000 0 x 0.000000 0 x 0.000000 0 x 0.000000 0 x 0.000000 0 x 0.000000 Output Circuits NAC/Output #1 0.000000 0.000000 NAC/Output #2 0.000000 0.000000 Total Standby Load 0.136280 Total Alarm Load 0.640000 Itall'lB"U'TIQAI ITflS by Honeywell MS-9050UD Battery Calculation Calculation in Total Sheet Required Standby Time in Hours 24 Hours Total Standby Current 1 0.1200 Amps x 24 = 2.880 AH Required Alarm Time in Minutes 5 Minutes Total Alarm Load 1 0.6400 Amps x 1 0.084 1= 0.054 AH Total Current Load 2.934 AH Multiply by the Derating Factor 1 1.2 1 = x 1.20 Total Ampere Hours Required 3.52 AH Fire -Lite Alarms Page 2 8/4/2014 SYMBOL MODEL NUMBER DESCRIPTION MANUFACTURE BACK BOX QTY AUDIO-VISUAL COMMON TROUBLE INDICATION MS -9050 FIRE ALARM CONTROL PANEL FIRLITE TYCO TO PROVIDE 1 FACP EXTERIOR WATER FLOW BELL FIRE ALARMS MANUAL FIRE ALARM STATIONS ANN-8O(W) ANNUNCIATOR FIRLITE TYCO TO PROVIDE 1 ANN FPL—TP J IPGSM-4G IP COMMUNICATOR HONEYWELL TYCO TO PROVIDE 1 XTMR X pi MMF-301 SINGLE INPUT MONITOR MODULE FIRELITE 4 SQ. DEEP BOX 2 Revision Issue BG12LX ADDRESSABLE PULL STATION FIRELITE 4. SQ. DEEP BOX 1 I' 1 O SD355 PHOTOELECTRIC SMOKE SENSOR FIRELITE 4 SQ. DEEP BOX 1 4 EXISTING FLOW SWITCH EXISTING, X 1 QBY OTHERS TAMPER SWITCH EXISTING 1 CEPTED o Without Comments As Noted in Red D Per The Attached Letter "These pians have been reviewed by The Tukwila Fire aention Bureau for conformance with current City :ndards. Acceptance is subject to errors and fissions which do not authorize violations of adopted :ndards and ordinances. Inc:. . re.soonsibility for the •enuacy of design rests total,y with the designer. ,editions, deletions or revisions to these drawings after chis date will voids this acceptance and will require a Pe-ubmittal of revised drawings for subsequent approval. Final acceptance Is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Rate: l/� i' t bio} en's ,`` t a f li exk4o- wea-I!I� _rroaf yon„/S' c X-.11-1-1,v.e ‘414:;:k3:4:elt\.k;`).,kietyi IC::: uri hc;,,,,,,f50 TUKWILA FIRE DEPARTMENT ?lease call 206-575-4407 and give this Fire Permit No. and exact address for shut- down hutdown or restoration approval. NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must. be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing GENERAL SYSTEM NOTES: 1. REPLACE EXISTING FIRE ALARM PANEL WITH NEW ADDRESSABLE FIRE ALARM PANEL. 2. CONNECT EXISTING SPRINKLER DEVICES TO NEW PANEL VIA MONITOR MODULES. 3. INSTALL NEW PULL STATION AT FACP. 4. INSTALL NEW ANNUNCIATOR AT FRONT ENTRANCE TO OFFICE. CABLE/CONDUCTOR LIST ANNUNCIATON AT FACP PANEL MASTERBOX SIGNAL TO ` DISPATCH AUX! LLARY EVAC SIGNALS FIRE ALARM SYSTEM . OPERATION MATRIX AUDIO-VISUAL COMMON TROUBLE INDICATION AUDIO-VISUAL SUPERVISORY INDICATION FIRE TROUBLE: AUDIO-VISUALGENERAL ALARM GENERAL Fl RE SHUT DOWN ALL SUPPLY AND RECIRCULATING FANS FACILITY FIRE EVACUATION AUDIO- VISUAL SIGNAL EXTERIOR WATER FLOW BELL FIRE ALARMS MANUAL FIRE ALARM STATIONS FPL—TP A 16//2 X X ANNUNCIATOR CIRCUIT FPL—TP J X RED JACKET DUCT SMOKE DETECTOR FIRE ALARM SYSTEM RELIABLE PARTS 1051 ANDOVER PARK WEST TUKWILA, WA X X X X WATERFLOW SWITCH 113 Revision Issue Date X X X X SMOKE DETECTOR X X X TROUBLE CONDITIONS X X FACP LOW BA 1 I ERY VOLTAGE FACP CIRCUIT FAULT X X FACPNOICE COMPONENT FAILURE X X FACP AC POWER FAILURE X X CEPTED o Without Comments As Noted in Red D Per The Attached Letter "These pians have been reviewed by The Tukwila Fire aention Bureau for conformance with current City :ndards. Acceptance is subject to errors and fissions which do not authorize violations of adopted :ndards and ordinances. Inc:. . re.soonsibility for the •enuacy of design rests total,y with the designer. ,editions, deletions or revisions to these drawings after chis date will voids this acceptance and will require a Pe-ubmittal of revised drawings for subsequent approval. Final acceptance Is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Rate: l/� i' t bio} en's ,`` t a f li exk4o- wea-I!I� _rroaf yon„/S' c X-.11-1-1,v.e ‘414:;:k3:4:elt\.k;`).,kietyi IC::: uri hc;,,,,,,f50 TUKWILA FIRE DEPARTMENT ?lease call 206-575-4407 and give this Fire Permit No. and exact address for shut- down hutdown or restoration approval. NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must. be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing GENERAL SYSTEM NOTES: 1. REPLACE EXISTING FIRE ALARM PANEL WITH NEW ADDRESSABLE FIRE ALARM PANEL. 2. CONNECT EXISTING SPRINKLER DEVICES TO NEW PANEL VIA MONITOR MODULES. 3. INSTALL NEW PULL STATION AT FACP. 4. INSTALL NEW ANNUNCIATOR AT FRONT ENTRANCE TO OFFICE. CABLE/CONDUCTOR LIST CIRCUIT TYPE CABLE TYPE NO. GAUGE ' COLOR NOTES I ADDRESSABLE INITIATING CIRCUIT FPL—TP A 16//2 RED JACKET ANNUNCIATOR CIRCUIT FPL—TP J 16/4 RED JACKET t,,,,,,, ,p, ki if FIRE ALARM SYSTEM RELIABLE PARTS 1051 ANDOVER PARK WEST TUKWILA, WA R ■ 113 Revision Issue Date ALL CABLES SHOULD BE SOLID AU. CONDUITS SHOULD BE 3/4'' UNLESS OTHERWISE NOTED ON PLANS. PAID .A1U 12 2f l TU WILA FIDE REPRESENTATIVE: KURT NITSCHMAN CHECKED BY: — CHECKED BY DATE: — APPROVED BY: — APPROVED BY DATE: — E RELIABLE 8/4/14 AS -SHOWN Sheet FA -01 11824 NORTHCREEK PRKWY N. Fire and SUITE 105 BOTHELL, WA 98011 Security PHONE: (425) 402-3351 FAX: (425) 415-6164 ,, .I .S. I LI t,,,,,,, ,p, ki if FIRE ALARM SYSTEM RELIABLE PARTS 1051 ANDOVER PARK WEST TUKWILA, WA R ■ 113 Revision Issue Date REPRESENTATIVE: KURT NITSCHMAN CHECKED BY: — CHECKED BY DATE: — APPROVED BY: — APPROVED BY DATE: — E RELIABLE 8/4/14 AS -SHOWN Sheet FA -01 F M03 M02 MO1 FIRE ALARM RISER DIAGRAM SCALE: NONE PLAN NORTH SYMBOL MODEL NUMBER DESCRIPTION MANUFACTURE BACK BOX QTY MS -9050 FIRE ALARM CONTROL PANEL FIRLITE TYCO TO PROVIDE 1 FACP ANN -80(W) ANNUNCIATOR FIRLITE TYCO TO PROVIDE 1 ANN IPGSM-4G IP COMMUNICATOR HONEYWELL NCO TO PROVIDE 1 XTMR FIRE ALARM SYSTEM RELIABLE PARTS 1051 ANDOVER PARK WEST TU KWI LA, WA MMF-301 SINGLE INPUT MONITOR MODULE FIRELITE 4 SQ. DEEP BOX 2 MM 1 Revision/Issue Date BG12LX ADDRESSABLE PULL STATION FIRELITE 4 SQ. DEEP BOX 1 F O SD355 PHOTOELECTRIC SMOKE SENSOR FIRELITE 4 SQ. DEEP BOX 1 \\ EXISTING FLOW SWITCH EXISTING 1 QBY OTHERS TAMPER SWITCH EXISTING 1 GENERAL SYSTEM NOTES: 1. REPLACE EXISTING FIRE ALARM FIRE ALARM PANEL. 2. CONNECT EXISTING SPRINKLER 3. INSTALL NEW PULL STATION AT 4. INSTALL NEW ANNUNCIATOR AT PANEL WITH NEW ADDRESSABLE DEVICES TO NEW PANEL VIA MONITOR MODULES. FACP. FRONT ENTRANCE TO OFFICE. REPRESENTATIVE: KURT NITSCHMAN CHECKED BY: — CHECKED BY DATE: — APPROVED BY: — APPROVED BY DATE: — Nki RELIABLE Set FA-02eine 11824 NORTHCREEK PRKWY N. Fire and SUITE 105 BOTHELL, WA 98011 Security PHONE: (425) 402-3351 FAX: (425) 415-6164 AS—SHOWN i :?. Fire & Security FIRE ALARM SYSTEM RELIABLE PARTS 1051 ANDOVER PARK WEST TU KWI LA, WA No. Revision/Issue Date REPRESENTATIVE: KURT NITSCHMAN CHECKED BY: — CHECKED BY DATE: — APPROVED BY: — APPROVED BY DATE: — Nki RELIABLE Set FA-02eine (Project d°8/4/14 AS—SHOWN p Without Comments ❑ As Noted in Re0 Per The Attached Letter These plans have been reviewed by The Tukwila Flre Prevention Burea4for conformance with current City standards. Acct i!ce is subject to errors and OilliSSIOrIS which i:,,thorize violations of adopted standards and or•ii33. The responsibility for the adequacy of desi n :: totally with the designer. Additions, deletioi•.s r,: vis ons to these drawings after this date will void cxeotance and will require a resubmittal of rev i •, - '", inr.js for subsequent approval. Final acceptance is scab? ct to veld test and Inspection by The Tukwila Fire Pczivention Bureau. Date: / ' a (n ( By: AV" 1/45i J Ur:WlLA FIRE DEPARTMENT F'1 call 206-575-4407 and give this Fire Permit No�, /(p - andp -s and exact address for shut- down hutdown or re:on approval. WOOD PURLIN MODEL #GST 20 ALL THREAD ROD HANGER RING 311111111.11M HANGER TYPE S NTS • ADJACENT WAREHOUSE SPACE (SAME TENANT) 1/2 1 ( 1 1 ---HALLWAY E 1 14 OFFICE fit° fr -///////////// // `-///// 1 E it", 11,2 11/2 EXISTING 1% OUTLET 1 2-4 [4 /////f///X//////%//////f////1//////1 € 1 1 10-0 ./iii/(iii//i/ OFFICE E 1 � / / r OFFICE / FIRE SPRINKLER PLAN SCALE: 1/4" =1'-0" ADJACENT WAREHOUSE SPACE (SAME TENANT) SITE SCOPE OF WORK: ADD AND RELOCATE SPRINKLERS AS REQUIRED FOR NEW WALLS AND CEILINGS. GENERAL NOTES: 1. ALL MATERIAL AND EQUIPMENT TO BE NEW AND UL AND/OR FM APPROVED. 2. PIPING DIMENSIONS ARE CUT LENGTH EXCEPT RISER DIMENSIONS AND MAINS, SHOWN THUSLY (1-6), WHICH ARE END TO END. 3. PIPE HANGER AND METHOD OF HANGING TO BE IN ACCORDANCE WITH NFPA #13 (2013). 4. PIPING SHALL BE IN ACCORDANCE WITH NFPA #13 (2013). 5. JOINING OF PIPE AND FITTINGS, THREADED AND WELDED, SHALL BE IN ACCORDANCE WITH NFPA #13 (2013). 6. OWNER TO PROVIDE ADEQUATE HEAT TO PREVENT WATER IN PIPES FROM FREEZING IN AREAS PROTECTED BY A WET PIPE SPRINKLER SYSTEM. 7. STRUCTURAL ADEQUACY OF THE BUILDING TO SUPPORT THE SPRINKLER PIPING IS THE RESPONSIBILITY OF THE OWNER AND/OR HIS STRUCTURAL REPRESENTATIVE. 8. ALL FIRE ALARMS, WIRING AND MONITORING ARE TO BE INSTALLED BY OTHERS. DESIGN NOTES: 1. DESIGN AND SPRINKLER SPACING TO BE PER NFPA #13 ORDINARY HAZARD. 2. PLAN SUBMITTAL TO AND APPROVAL BY THE CITY OF TUKWILA. 3. MATERIALS PER NFPA #13 STANDARDS AS SELECTED BY FSI. 4. TESTING PER NFPA #13 AND THE CITY OF TUKWILA. FIELD NOTES: 1. ALL NEW PIPE TO BE BLACK, IMPORT SCHEDULE 40 WITH BLACK, DUCTILE IRON THREADED FITTINGS. 2. SPRINKLERS ARE NOT REQUIRED TO BE LOCATED IN THE CENTER OF THE CEILING TILES. 3. ARMOVERS LONGER THAN 21-0" SHALL HAVE A HANGER. 5. TYPICAL HANGER TO BE SAMMY MODEL GST -20. 5. MAX SQ FT PER SPRINKLER = 130 SQ FT. WALL LEGEND: = EXISTING WALLS ////////// = NEW WALLS SPRINKLER PIPE LEGEND: -- -- --- - = EXISTING SPRINKLER PIPE - NEW SPRINKLER PIPE SPRINKLER LEGEND: E = EXISTING PENDENT SPRINKLER LOCATION • R = RELOCATED PENDENT SPRINKLER 0 A = NEW PENDENT SPRINKLER • = EXISTING UPRIGHT SPRINKLER VICINITY MAP SCALE: NTS FR_ ECop Y Omooesemomoeeeooeoeoeooeeeeesae WASHINGTON STATE CERTIFICATE OF COMPETENCY FIRE PROTECTION SPRINKLER SYSTEPAS David Usiecki 1470-0793-C Level 3 Fire Sprinkle Incorporated FIRESIr98£ J cc 0 VICINITY MAP SCALE: NTS p ID .. 7 4' anis -i DRAWING SYMBOLS - WELDED PIPE TAG w Z Uw Z CO wI - 0 ° z ww aas 0 1- 0 0 toZ w acs 0 Z 0 W Q w0 w L AIX w Z 0 CC W Jf- ILI G. za o UOQ 1- 0 w 0z J 0d 20 HYDRAULIC NODE HANGER LEGEND COACH SCREW ROD TOP BEAM CLAMP W/ STRAP CEILING FLANGE SIDE BEAM BRACKET WEDGE ANCHOR SAMMY SUPER SCREW (GST20) SAMMY SIDEWINDER (SWG20) SAMMY X -PRESS w Iv w Il m C9 CIO SPRINKLER HEAD LEGEND c5 0 w c) >- a. O U w 0 U 0) LL w ce 0 a w 1- 0 1- N U Ur cfl J O CAI 0) 0 - J w 0 0 0 LL 0 Z SPRINKLER TYPE / SIN NUMBER Q.R. STANDARD SPRAY PENDENT WITH 2 -PC ESC. TOTAL THIS SHEET CO CO CO ca ct 0-00 Jce z 45 CO _ o -J <- ct 12:2o 0, ire CO ti i 0LC) :133fQtid :H1/M 13VaLNO3 N CZei En ON 4.0 W� D. et � N Ln U w !1) J w w W 0 0 January 14, 2016 co [o 0 U 1- 26(11 21)t2,01) -