HomeMy WebLinkAboutPP - 1071 ANDOVER PARK WEST - BEKINS NWEST - PERMITS AND PLANS1071 ANDOVER PARK WEST ASSOCIATED PERMITS 14-F-120 EL14-1090 10-F-030 Date: 7/21/17 TUKWILA FIRE DEPARTMENT OPERATIONAL PERMIT 74-17 By virtue of The Provisions of the International Fire Code adopted by City of Tukwila Ordinance, Bekins Northwest located at 1071 Andover Park West having made application in due form, and as the conditions, surrounding, and arrangements are, in my opinion, such that the intent of the Ordinance can be observed, authority is hereby given and the PERMIT is granted *To use a building or portion thereof as a high -piled storage area exceeding 500 square feet (46m2) per Chapter 32 of International Fire Code 105.6.23. This PERMIT is issued and accepted on condition that all Ordinance provisions now adopted, or that may hereafter be adopted, shall be complied with. THIS PERMIT IS VALID FOR -Twenty-four Calendar Months - Fire Marshal THIS PERMIT MUST BE POSTED ON THE PREMISES MENTIONED ABOVE. Operational Permit Long 2017.dotx Rev. 6/8/17 TFP #2 INSPECTION NUMBER INSPECTION RECORD Retain a copy with per PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project:craw iii e Type of In on: Address: l A Suite #: 7� ) �j(/ Contact son: Special Instructions: Occupancy Type: Phone No.: Approved per applicable codes. CO MENTS: Corrections required prior to approval. f/A 3201-f/e k cid Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: inspector:/,�l3 Date: /jJZ/f y Hrs.: i_ d $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with perc�it r' ,J r.. QO .tL i -F- iZo PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: &-y6014,19,r- Type of Ins ction: rA Address: 07/ Suite #: vi Contact erson: Special Instructions: Occupancy Type: Phone No.: , ,vim Pood‘ Corrections required prior to approval. 2 � ; — @__ Pick-KiL UZ 5 -i -A d ry ivo t A-‘/ ivo Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector -- ,4j 53 Date: /1//91/(1 Hrs.: �- $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. CaII to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F,D. Form F.P. 113 TUK YJILA FIRE PREVENTION BUREAu 1 444 Andover Park East, Tukwila, WA 98188 - Phone 206-575-4407 - Fax 206-575-4439 E-mail: tukfdpry@ci.tukwila.wa.us CONTRACTORS MATERIAL AND TEST CERTIFICATE FIRE ALARM AND FIRE DETECTION SYSTEMS Fire alarm System is ready for Fire Department acceptance testing. Failure of test will result in termination of the testing and additional fees will he assessed. Contractor is responsible for supplying manpower for Final Acceptance Test with two-way communications. Permit # (/ Y - ra `t n -- ' f r L 0 611,4.40 2r Jftta Ld Suite # Date 12- 2- !L( Property Address / 07 0 City _TUKWILA Name of Facility CP ow 'J /t Zip Code NA -7(00 0 O.L Occupied as CyL o w y) Y �"' {Q ‘.`� Owner or Representative Phone # Installing Company c 7 0 S Installing Contractor's Address (' A LS— 6 2_ A-6 - 1 ti 4 G / / L City ' „,�-- Phone # 2 53 - 776 " 72- Installer's 2 Installer's Name (PRINT) Ci .-.Z 2 License and/or Certificate C k A2 i� Z -t �c� l C o C) General Contractor Electrical Contractor FACP Equipment Manufacturer it le Model #LA 1-1 .44) ck(95---D u - This system has been installed. pre -tested and operates in accordance with the standards listed below and was inspected by b4.,j i'o CA et 47 4-4- / 4+ 14-e L On (date) (L - L — i ( and includes the devices listed on back. Circle all that apply: NFPA 72, Chapter 1 2 4 5 6 7 and/or IFC SEC 907 NFPA 70, National Electrical Code, Article 760 Manufacturer's Instructions Manufacturer's Instructions Other (specify) Tukwila City Ordinance Numbers 2050, 2051 UL Central Station iM.niton System is monitored by V 1 Date jz-2_—y SIGNED System Firmware: Installed version Initial program Installation Checksum Date Revisions and Reasons Date Programmed by elk EQUIPMENT INSTALLED AND TESTED: Control Panel L of 4_ Make/Model l/l N()U.o9es- / CIO (4 Q Manual Station_ of Make/Model Smoke Detectors j of ( Make/Model /'!is- / (. ( C D 3 S Heat Detectors of Make/Model Duct Detectors of_ Make/Model AN Devices — of Make/Model Audio Devices— of Make/Model Visual Devices_ of _ Make/Model Auto Door Release_ of Make/Model Trouble Indictors of Make/Model Batteries Readings Battery IC t --1C Full Load 2.551.s 7 Charge 2 ? )3 Generator_ of _ Make/Model HVAC Controls of Make/Model Fire Alarm Dialer of Make/Model Monitored by T‘,1 C O /do nen_5/2 4 --e S [i1 Annunciator of Make/Model Sprinkler Cystem. (Fire Alarm connections only; -- 4ti ater Flow S,q v, . o f ( Make/Model ` O (iv -S: , - Valve Tamper Sw, ( of ( Make/Model / tt e % S PIV L of k Make/Model i l /� a2_ /' JQ / Elec. Alarm Bell of Make/Model Automatic time Delay of Water Flow Alarm seconds. None Installed Do you meet audible/visible requirements of WAC 51-20, IFC SEC 907., and/or NFPA 72 Chapter 6? Yes_ No0 Test of alarm System on emergency power, satisfactory? Yes ) No _ Test Witnessed by (7 Title Date Comments: eddins\Fire Alarm Certificate.doc Revised: 10/28/04 TFD FP Form #110 4tr CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. SITE LOCATION 1071 Andover Park W Site Address: Suite Number: Floor: Crown Mayflower Tenant Name: New Tenant? 0- Yes f - No Yongsin Kang **PLEASE PRINT** RECEIVED APRno�totq TUgWILA FIRE 262304-9121 King Co. Assessor's Tax No.: Property Owner's Name: Mailing Address:1071 Andover Park W CONTACT PERSON -if there are questions about the submittal. Name:Wendy Coile Company Name:TYCO INTEGRATED SECURITY LLC City State Zip 253-620-5971 Day Telephone: 11824 NORTH CREEK PKWY N # 105, BOTHELL WA 98011 Mailing Address: wcoile@tyco.com City State Zip E-mail Address: Fax Number:888-400-0383 Valuation of Project (contractor's bid price): $ I 1 I Site Contact:Jeff Otterstad (206)336-2500 Scope of Work (please provide detailed information): Scope: Transmitter Replacement UDAC/TG7 PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWN • OR AUTHORIZED AGENT: Signature: Print Name: 66,1411 //IOC ll/C t A. Plan Permit App.doc Date: 206-774-9499 Day Telephone: qA/ly 5/14/10 TFD FP Form S Scope Of Work Project Name: CROWN MOVING CO INC. 1071 ANDOVER PAR W. TUKWILA, WA 98188 For: Fire Alarm System By: TYCO Security Services 11824 North Creek Parkway N., Suite 105 Bothell, WA 98011 Contact: JEFF MCLAUGHLIN Phone: 206-854-1993 E -Mail: JMCLAUGHLIN@TYCO.COM New Equipment: Quantity Model Description 1 MS-9505UD FIRE ALARM CONTROL PANEL 1 SD355 SMOKE DETECTOR 1 TG-7FS TELGUARD CELLULAR UNIT 7 MMF-300 ADDRESSABLE MONITOR MODULE 1 CONNECTION TO WATERFLOW SWITCH 1 CONNECTION TO TAMPER SWITCH 1 CONNECTION TO PIV 1 CONNECTION TO DRY FLOW SWITCH 1 CONNECTION TO DRY TAMPER SWITCH 1 CONNECTION TO DRY PRESSURE SWITCH 1 CONNECTION TO SYSTEM BACKFLOW NOTES: 1. Tyco to install new addressable panel. 2. Tyco to connect to existing fire sprinkler devices with addressable monitor modules. 3. Tyco to remove existing outdated STU. Cellular unit will be used for communication of the fire alarm events to the central station. Co FlreturerALarms MS-9050UD Battery Calculation Regulated Load in Standby Device Type yp Number of Devices Current (Amps) Total Current (Amps) Main Circuit Board 1 x 0.120000 = 0.120000 4XTMF 0 x 0.005000 = IPDACT-2 0 x 0.093000 = IPDACT-2/2UD 0 x 0.098000 = 4 -Wire Smoke Detectors 1 0 x 0.000000 = Power Supervision Relays ` 0 x 0.025000 = ANN -80 (-W) 0 x 0.015000 = ANN-(R)LED 0 x 0.028000 = ANN -I/O 0 x 0.035000 = ANN -I/O LEDs 0 x 0.000000 = ANN-S/PG 0 x 0.045000 = ANN-RLY 0 x 0.015000 = Addressable Devices BEAM355 and BEAM355S 0 x 0.002000 = BEAM 1224 0 x 0.017000 = CP355 0 x 0.000300 = SD355 1 x 0.000300 = 0.000300 SD355T 0 x 0.000300 = AD355 0 x 0.000300 = H355 0 x 0.000300 = H355R 0 x 0.000300 = H355HT 0 x 0.000300 = D350P 0 x 0.000300 = D35ORP 0 x 0.000300 = D355PL 0 x 0.000300 = MMF-300 7 x 0.000400 = 0.002800 MMF-300-10 0 x 0.003500 = MDF -300 0 x 0.000750 = MMF-301 0 x 0.000375 = MMF-302 0 x 0.000270 = MMF-302-6 0 x 0.002000 = BG-12LX 0 x 0.000230 = CMF -300 0 x 0.000390 = CMF -300-6 0 x 0.002250 = CRF -300 0 x 0.000270 = CRF -300-6 0 x 0.001450 = 1300 0 x 0.000400 = B501 BH & B501 BHT 3 0 x 0.001000 = B224RB Relay Base 0 x 0.000500 = B224BI Isolator Base 0 x 0.000450 = B200SR Sounder Base 0 x 0.000500 = CDRM-300 0 x 0.001300 = Current Draw from TB3 - EIA -485 0.000000 4 Total Standby Load 0.123100 Notes: 1) Refer to the Device Compatibility Document for standby current 2) Must use compatible listed Power Supervision Relay 3) Maximum alarm current for each sounder base is 0.015 amps which must be supplied by aux. 24VDC source. 4) Total current draw listed cannot exceed 2.7 amps Page 1 of 3 FlreuTerALarms MS-9050UD Battery Calculation Regulated Load in ALARM Device Type Number of Devices Current (Amps) Total Current (Amps) Main Circuit Board 1 x 0.200000 = 0.200000 4XTMF' 0 x 0.011000 = IPDACT-2 0 x 0.136000 = IPDACT-2/2UD 0 x 0.155000 = 4 -Wire Smoke Detectors 0 x 0.000000 = Power Supervision Relays 0 x 0.000000 = ANN -80 (-W) 0 x 0.040000 = ANN-(R)LED 0 x 0.068000 = ANN -I/O 0 x 0.200000 = ANN -I/O LEDs 0 x 0.010000 = ANN-S/PG 0 x 0.045000 = ANN-RLY 0 x 0.075000 ALL Addressable Devices - Maximum draw 1 x 0.400000 = 0.400000 NAC #1 ` 0 x 0.000000 = NAC #2 0 x 0.000000 = Current Draw from TB3 - EIA -485 0.000000 3Total Alarm Load 0.600000 Notes: 1) If using the Reverse Polarity Alarm output, add 0.005 amps; if using the Reverse Polarity Trouble output, add another 0.005 amps. 2) Current limitations for NAC circuits TB1 is 2.5 amps per circuit 3) Total alarm current cannot exceed 2.7 amps Page 2 of 3 ®FIretuTeMAIMS MS-9050UD Battery Calculation Note 1: You can edit all current draws and are fully responsible for Note 2: You only need to make entries in the yellow cells verifying these calculations. Calculation in Total Sheet Use the total standby and alarm load currents calculated in tables A calculations -2A and A -2B for the following battery Required Standby Time in Hours (24 or 60 Hrs.) Standby Load Current (Amps) 1 0.123100 1 x 24 = 2.954 AH Required Alarm Time in Hours (5 minutes = 0.084) Alarm Load Current (Amps) 1 0.600000 1 x 0.084 1 = 0.050 AH Total Current Load 3.005 AH Multiply by the Derating Factory 1.2 1 = x 1.20 Total Ampere Hours Required 3.606 AH The MS-9050UD can charge this size battery The batteries can be stored in the cabinet Current Draw Check 'NAC#1 current is within the limitations of the circuit. NAC#2 current is within the limitations of the circuit. MS-9050UD current draw: The required output current is within the panel's limitations Page 3 of 3 STATEWIDE SECURITY 1101 Andover Park W. G -Force Associates FILE Scope of work. Connect HVAC Smoke Detector located in HVAC unit on roof to the Digital Monitoring Products XR 200 Alarm Panel located in the sprinkler riser room for remote monitoring. Currently the alarm system monitors water flow and valve tampers. There are no pull stations or audible devices connected to the system. The control keypad for ackknowledging and silencing the alarm panel is also located in the sprinkler riser room. The new duct detector was installed by the HVAC contractor and is powered by the HVAC unit. Resetting the detector after an alarm is done thru the HVAC system. The detector is connected to the alarm system via an point exspantion module. It has a unique point id and the point is programmed as a supervisory point (not an alarm point). Upon activation and signal received at Mace Central Station, ( Anaheim CA. 1800-228-0580) the building manager and Statewide service technician will be notified. Mark Hanft cell 206-730-2723 ACCEPTED E Without Comments O As Noted in Red O Per The Attached Letter These plans have been reviewed by The Tukwila Fire "revention Bureau for conformance with current Clty :lndards. Acceptance is subject to errors and •:1m sslons which do not authorize violations of adopted andards and ordinances. The responsibility for the :: dequaty of design rest;-' totally with the designer. Additions, deletions or revisions to these drawings after this date will void this acceptance and will requires resubmittal of revised drawings for subsequent approval. Final acceptance is suoeect to Heid test and inspection by The Tukwila Fire Prevention Bureau. Date.: -t -/0 By:A-1,c/ E WI.A FIRE DEPART$4 M'k Please call: 575.4407 and give this job No.JQ-/-030 and exact address for shut. sown or restoration epnrnusil P.O. BOX 2019 • REDMOND, WA • 98073 PHONE: 425-558-4640 / 1-800-215-6555 • FAX: 425-558-1290 STATE CONTRACTORS #: WA STATES*044QF WA SHAMRSS99IKW CA ACO 4403 763287 ID 18852 AZ ROC178402 MT 148438 I FEB 1 '2010 Tukwila Fire M07 M06 V V BF N VI MOS MV M04 M03 FIRE ALARM RISER DIAGRAM � SCALE: NONE PLAN NORTH My SYMBOL MODEL NUMBER DESCRIPTION MANUFACTURE BACK BOX QTY MS -9050 FIRE ALARM CONTROL PANEL FIRLITE NCO TO PROVIDE 1 FACP TG-7FS CELLULAR RADIO TELGUARD NCO TO PROVIDE 1 XTMR O SD355 PHOTOELECTRIC SMOKE SENSOR FIRELITE 4 SQ. DEEP BOX 1 MMF-300 SINGLE INPUT MONITOR MODULE FIRELITE 4 SQ. DEEP BOX 7 MM Date EXISTING FLOW SWITCH EXISTING 2 EXISTING PRESSURE SWITCH EXISTING 1 T 4 EXISTING TAMPER SWITCH EXISTING 2 Q EXISTING BACKFLOW EXISTING 1 ® EXISTING Ply EXISTING 1 V1 IV M02 PIV v\A MO1 VV sol 111 FAC XT V GENERAL SYSTEM NOTES: 1. REPLACE EXISTING FIRE ALARM PANEL AND STU FIRE ALARM PANEL. 2. INSTALL NEW TELGUARD CELLULAR TRANSMITTER 3. CONNECT EXISTING SPRINKLER DEVICES TO NEW WITH NEW ADDRESSABLE AT NEW PANEL. PANEL VIA MONITOR MODULES. • REPRESENTATIVE: JEFF MCLAUGHLIN CHECKED BY: — CHECKED BY DATE: — APPROVED BY: — APPROVED BY DATE: — CROWN Sheet FA -02 11824 NORTHCREEK PRKWY N. Fire and SUITE 105 BOTHELL, WA 98011 Security PHONE: (425) 402-3351 FAX: (425) 415-6164 •..1 :.. LI. ots t 2 0 4 %.4 j, ...• - irip FIRE ALARM SYSTEM CROWN MOVING 1071 ANDOVER PARK W TUKWILA, WA 98188 No. Revision/Issue Date REPRESENTATIVE: JEFF MCLAUGHLIN CHECKED BY: — CHECKED BY DATE: — APPROVED BY: — APPROVED BY DATE: — CROWN Sheet FA -02 [ject 5/31/14 1s AS -SHOWN