PP - 665 ANDOVER PARK WEST - S.C. CORPORATE SQUARE BLDG - PERMITS AND PLANS
665 ANDOVER PARK WEST ASSOCIATED PERMITS 16-F-017 SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** q _" } i , King Co. Assessor's Tax No.: k Site Address: 1..1 .� r (! 0 V � PG. V� W'i -+ Suite Number: r5 �� 1C, Ark iCX (i(% V p 562 –1 c Ct(, "t r v New Te ant? Property Owner's Name: I (;1 C lti"r f ?i oil tLC C/ rn Cuic Et,P{nie 44 - Tenant Name: Floor: ❑ - Yes 5 -No Mailing Address: 1,,?)6 ,Yl C CV C'VT [(,V L V lc it 107 . 1 1,1,k_ Ni`(a1 \J et q U City State Zip CONTACT PERSON -if there are questions about the submittal. Name: L'(/Ct. YV)L T ti Day Telephone: 2J)(, (U(,1 2:7 Company Name: V11✓t, IN (C,utccfr kin4.111) Mailing Address: 1-7L) t —) /4 C wmi g 1504-2 E-mail Address: L-- rt 1V' C &(itLSCij C C(1 Cl rYYi . 1,D /Y'City Fax Number: - �J t)�7 Contractor's City of Tukwila Business License number: i3U.S " CA CI -32-39 Total number of new/relocated devices or sprinkler heads: Valuation of Project (contractor's bid price): $ 11111,( t dl ICi, 4C,t.I (_L -` t Scope of Work (please provide detailed information): �J i A te-+ - CP t CLa h r ' Ak I cta✓i GlAv1 \A) ilty)-(4,0 PERMIT APPLICATION NOTES Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: 'UV Leo Print Name: Lt/a Y) i/C/ Vi/f' S 'PAID 2" 20r TUKWILA FIRE Plan Permit App.doc Date: Day Telephone: 2i2 -2-6S 7 8/22/14 , 2F757 TFD FP Form 8 Cascade Fire & Security BY: CASCADE ALARM P.O. BOX 7459, KENT, WA 98042 • PH: 206-767-5800 • FAX: 253-630-4851 Emergency Fire Alarm Panel Replacement Scope of Work: 1. Replace existing Conventional SK5207 FACP with new addressable SK5700 FACP. 2. Replace existing power supply. 3. Replace (5) conventional pulls with new Silent Knight addressable SK -Pulls. 4. Replace (5) conventional smokes with new Silent Knight SK -Photo Smokes. a. 1 above FACP b. 1 at top of elevator shaft c. 2 for elevator recall (1St & 2nd floor) d. 1 in elevator machine room 5. Install Addressable module at (1) existing duct detector 6. Install (9) addressable modules for tampers and waterflows. a. 1 hi/low air b. 1 Wet waterflow c. 1 Dry waterflow d. 1 Elevator Tamper e. 2 OS&Y Tampers (vault) f. 1 Tamper at dry riser g. 2 PIV tamper 7. Install (1) Weatherproof horn strobe on outside of building 8. Connect All existing horn strobes to new FACP/power supply. PAID xiNN 2 =' 2f 1F TUKWILA FIRE *-21- 7 37 * 24 HOUR SERVICE - LICENSED, BONDED, NICET CERTIFIED, INSURED * Washington State Contractor's License # CASCAAL963JT/CASCAAL962RW is a' "First When Seconds Count" INTELLIKNIGHT FIRE ALARM CONTROL PANEL SILENT KNIGHT by Honeywell IntelliKnight® Model 5700 Single Loop Addressable Fire Alarm Control System The affordable addressable fire alarm control panel solution. IntelliKnight Model 5700 is a class leading single loop addressable fire alarm control/communicator system. 5700 provides you with the revolutionary value and performance of addressable sensing technology combined with exclusive, built-in digital communication, distributed intelligent power, that includes an easy to use interface. Powerful features such as drift compensation and maintenance alert are delivered in this powerful FACP from Silent Knight. For more information about the IntelliKnight system, or to locate your nearest source, please call 1-800-328-0103. Description The basic IntelliKnight 5700 system can be enhanced by adding modules such as 5860 remote annunciator, 5824 serial/parallel printer interface module (for printing system reports), and 5496 intelligent power module. 5700 supports SD or SK devices. 5700 also features a powerful built-in dual line fire communicator that allows for reporting of all system activity to a remote monitoring location. Features • Built-in support for up to 50 SK detectors and 50 SK modules creating a total point capacity of 100 points • Built in support for up to 50 SD devices • Up to 125 zones and 125 output groups • Uses standard wire—no shielded or twisted pair required • Built-in digital communicator • Central station reporting by point or by zone • Supports Class B (Style 4) and Class A (Style 6 or 7) configuration for SLC • Drift compensation • 13 pre-programmed output cadences (including ANSI - 3.41) and 4 programmable outputs • Notification circuits configurable as 1 Class A (Style Z) or 2 Class B (Style Y), or auxiliary power for resettable, constant, or door holder power • Built-in synchronization for AMSECO, Gentex®, Faraday, System Sensor® and Wheelock® appliances • Built-in annunciator with 80 -character LCD display • RS -485 bus provides communication to system accessories • Upload or download programming, event history, or detector status onsite or from a remote location using a PC and 5660 Silent Knight Software Suite (SKSS) • Two built-in Form C programmable relays rated at 2.5A at 27.4 VDC Model 5700 • Improvements in SKSS deliver five times faster upload/downloads • Built-in RS -232 interface for programming via PC • Built-in Form C trouble relay rated at 2.5A at 27.4 VDC • Programmable date setting for Daylight Saving Time Compatibility The 5700 signal line circuit (SLC) supports multiple device types of the same protocol: • SK • SD You cannot mix SD and SK SLC devices on a FACP. P/N 350392 Rev M © 2014 Honeywell International Inc. INTELLIKNIGHT FIRE ALARM CONTROL PANEL Model 5700 Fire Alarm Control Panel 5496 Specifications_ Electrical Primary AC: 120 VAC, 60 Hz, 1.5A Total Accessory Load: 2.5A @ 27.4 VDC Notification Power: 2.5A @ 27.4 VDC, power -limited Standby Current: 200 mA Alarm Current: 365 mA Notification/Aux Power Circuits: 2.5A @ 27.4 VDC per circuit, power -limited Battery Charging Capacity: 7.0-35.0 AH Battery Size: 7 AH max. allowed in FACP cabinet. Larger capacity batteries can be housed in an RBB accessory cabinet. Physical Dimensions: 12.75" W x 15.2" H x 3.4" D (32.39 W x 38.42 H x 8.57 D cm) Weight: 11.5 lbs. (5.2 kg) Color: Red Telephone Requirements: FCC Part 15 and Part 68 approved Type of Jack: RJ31X (two required) Listings NFPA 13, NFPA 15, NFPA 16, NFPA 70, & NFPA 72: Central Station; Remote Signalling; Local Protective Signalling Systems; Auxiliary Protected Premises Unit; & Water Deluge Releasing Service. Suitable for automatic, manual, waterflow, sprinkler supervisory (DACT non -coded) signalling services. Other Approvals: UL Listed; CSFM 7170-0559: 144; MEA 429-92-E Vol. XVI; OSHPD (CA) OSP-0065-10 S -BUS Accessories 5860/R Remote Fire Annunciator Features the same 80 character backlit LCD display keypad and firefighter's key switch as the 5700. The system can be fully programmed and operated from any 5860. 5860 is gray and 5860R is red. 5496 Intelligent Power Module A 6 amp notification power expander that provides four additional power -limited notification appliance circuit outputs. 5880 LED/IO Module Features 40 LED outputs, 8 normally open dry contact inputs and one piezo output. 5865-3 and 5865-4 Remote LED Annunciator Features 30 Programmable LED (15 red and 15 yellow) outputs and a piezo sounder. The 5865-4 adds a silence and reset switch to the package. 5883 Relay Board Features 10 general purpose Form C relays. Used with 5880 module. 5824 Serial/Parallel Printer Interface Module Provides one parallel and one RS -232 serial port for connecting a printer to 5808. Use to print a real-time log of system events, detector status reports, and event history. Interfaces with building control system. Miscellaneous Accessories 5660 Silent Knight Software Suite User-friendly Windows software for remote programming of 5700s using a PC. Upload and view panel account information, event history, and detector status. 5670 Silent Knight Software Suite End-user facility management software allows viewing of detector status and event history via modem or direct connection. RBB Remote Battery Box Accessory Cabinet. Use if backup batteries are too large to fit into FACP cabinet. Dimensions: 16" W x 10" H x 6" D (406 mm W x 254 mm H x 152 mm D SK -SCK Seismic Compliance Kit. SD505-DTS-K Remote test switch that provides remote key operated test function and annunciation of detector alarm with SD505-DUCTR. SP -TR Small panel trim ring. Use to flush mount the panel. 16.975" H x 14.630" W. SD and SK Devices See the data sheets listed below for a complete listing of the SD and SK devices. 53624 SD Devices data sheet 53623 SK Devices data sheet SILENT This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all KNIGHT specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 12 by Honeywell Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118. For Technical Support, Please call 800-446-6444. www.silentknight.com Assembled In America INTELLIKNIGHT ACCESSORY SILENT KNIGHT by Honeywell SK -Pull -SA and SK -Pull -DA Intelligent Pull Stations The SK -Pull -SA and SK -Pull -DA are a single action or dual action addressable fire alarm pull station for use with Silent Knight's IntelliKnight fire control panel. Extremely easy to operate, the SK -Pull -DA and SK -Pull -SA provide a fast and practical means of manually initiating a fire alarm signal. The IntelliKnight panel recognizes each manual pull station by its specific address saving precious seconds in determining the location of an alarm. For more information about the IntelliKnight system, or to locate you nearest source, please call 1-800-328-0103. Description The SK -Pull -SA is a single action pull station requiring only one motion to activate the station. The SK -Pull -DA is a dual action pull station requiring two motions to active the station. Both pull stations are designed to work with Silent Knight Intelliknight series fire alarm control panels (FACPs). Features • Installer can open station without causing an alarm condition • Dual -color LED is visible through handle of station blinks green to indicate normal operation and remains steady red in an alarm condition • Key operated test and reset lock using lock plate actuator • Key matches compatible FACP locks • Meets the Americans with Disabilities Act Accessibility Guidelines (ADAAG) controls and operating mechanisms guidelines (Section 4.1.3[13]) • Meets ADA requirement for 5 lbs maximum pull force to active • Shell, door, and handle molded from durable LEXAN® • Reliable analog communications for trouble-free operation • Braille text on station handle • Handle latches in down position and the word Activated appears, clearly indicating the station has been pulled • Rotary address switches for fast installation • UL Listed, including UL 38, Standard of Manually Actuated Signaling System SK -Pull -SA SK -Pull -DA Compatibility The SK -Pull -SA and SK -Pull -DA are compatible with the following IntelliKnight FACP's: 5600 5700 5808 5820XL 5820XL-EVS INTELLIKNIGHT ACCESSORY Model SK -Pull -DA and SK -Pull -SA Intelligent Pull Stations Engineering Specifications The contractor shall furnish and install where indicated on the plans, Addressable Pull Stations, Silent Knight model SK -Pull -SA single action pull station or SK -Pull -DA, dual action pull station. SK -Pull -DA or SK -Pull -SA meet the ADAAG controls and operating mechanisms guidelines, and the ADA requirements for a 5 Ib. maximum pull force to activate the pull station. Compatible FACP Class A Wring: --- Class ^--•••-•Class B Wiring. Class B Class A 17 Wiring SK -Pull -SA & SK -Pull -DA Pull Stations Specifications Physical Height: 5.5" (14 cm) Width: 4" (10.2 cm) Depth: 5.4 oz. (3.7 cm) Housing Material: LEXAN polycarbonate resin Bi -Colored LED: Blinking Green: Normal Steady Red: Alarm Switch: Single pole, single throw (SPST) normally open (N/O) switch which closes upon activation of the pull station Electrical Operating Voltage: 15-32 VDC Average Operating Current (LED flashing): 300 pA Wire Gauge: Up to 12 AWG (3.1 mm2) Environmental Operating Temperature 32° — 120°F (0°C — 49°C) Humidity: 10% — 93% non -condensing Accessories BG -TR SB -I/O Optional trim ring. Surface backbox fts SILENT KNIGHT by Honeywell This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118. For Technical Support, Please call 800-446-6444. www.silentknight.com MADE IN AMERICA FORM# 350135 Rev C © 2013 Honeywell International Inc. INTELLIKNIGHT ACCESSORY SILENT KNIGHT by Honeywell SK -Photo, SK -Photo -T fi and SK-PhotoR Intelligent Photoelectric Smoke Sensors The SK -Photo is a photoelectric smoke detector, the SK -Photo -T is a photoelectric smoke detector with thermal and SK-PhotoR is a photoelectric detector with remote test capability. These plug in smoke detectors, with integral communication, provide features that surpass conventional detectors and are for use with Silent Knight IntelliKnight Fire Alarm Control Panels (FACPs). For more information about the IntelliKnight system, or to locate your nearest source, please call 800-328-0103. Description SK -Photo and SK -Photo -T are plug-in type smoke sensors that combine a photoelectric sensing chamber with addressable analog communications. Point ID capability allows each detector's address to be set with rotary address switches, providing exact detector locations for selective maintenance when chamber contamination reaches unacceptable levels. SK -Photo and SK -Photo -T have a unique optical sensing chamber that is engineered to sense smoke produced by a wide range of combustion sources. In the SK -Photo -T, dual electronic thermistors add 135°F (57°C) thermal technology to maximize detection. The SK-PhotoR is a remote test capable detector for use with the DNR/DNRW duct smoke detector. (not included) Features • Sleek, low -profile design • Base included • Reliable analog communications for trouble-free operation • Age resistant polymer housing • Dual electronic thermistor design on the SK -Photo -T • Superior EMI resistance for reliability • Simple field cleaning for code compliance • Variety of mounting options to meet any application • Dual LED indicators for 360° visibility • Detector transmits signal to indicate maintenance is required • Optional remote LED annunciator (System Sensor® PN RA100Z) • Plug-in mounting provides ease of installation • Tamper -proof feature available on mounting bases • Listed for use in duct applications • Rotary address switches for fast installation • UL Listed • FM Approved Specifications Physical Height: 2.0" (5.0 cm) Diameter: 4.1" (10.4 cm) installed in B501 base Electrical Operating Voltage: 15-32 VDC Standby Current: 300 pA @ 24 VDC Maximum Alarm Current: 6.5 mA @ 24 VDC max (with LED on) Environmental Operating Temperature SK -Photo: 32° — 120°F (0°C — 49°C) SK -Photo -T: 32° — 100°F (0°C — 38°C) Humidity: 10% — 93% non -condensing Other Ratings SK -Photo -T Thermal: Fixed temperature set point 135°F (57°C) Velocity: 0 — 4000 fpm (0 — 20 m/sec) SK -Photo (Base included) Installation The SK -Photo and SK -Photo -T plug into a compatible IntelliKnight-series detector base. The SK-PhotoR is a remote test capable detector head included within the DNR (W) duct smoke detector. Compatibility SK -Photo, and SK -Photo -T are compatible with the following detector bases: B210LP 6" base (included) B501 2 wire base B224RB Relay base B224B1 Isolator base B200SR Sounder base The SK -Photo, SK -Photo -T, and SK- PhotoR are compatible with the following IntelliKnight FACPs: 5820XL 5820XL-EVS 5808 5700 5600 (Rev 2.0 or higher) INTELLIKNIGHT ACCESSORY Model SK -Photo, SK -Photo -T and SK-PhotoR Intelligent Photoelectric Smoke Sensors Engineering Specifications The contractor shall furnish and install where indicated on the plans, Intelligent photoelectric smoke sensors Silent Knight SK -Photo or SK -Photo -T with thermal. The combination detector head, and twist -lock base, shall be UL listed and compatible with Silent Knight's IntelliKnight fire control panels. The base shall permit direct interchange with SK -Photo or SK -Photo -T. Base shall be the appropriate twist -lock base part number B210LP (included). The PhotoR is a remote test capable detector for use with DNR(W) duct smoke detectors. (not included). The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady. The detector may be reset by actuating the control panel reset switch. The calibration of the detector shall be capable of being selected and measured by the control panel without the need for external test apparatus. The vandal -resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field selectable as required. The SK -Photo shall automatically perform a functional test of the detector. The test method shall simulate effects of products of combustion in the chamber to ensure testing of detector circuits. SLC 1N OUT Compatible FACP RA100Z (Optional) Class A Optional Wiring Wiring SKSerles Detector Mounting Bases SILENT This document is not intended to be used for installation purposes. We try to KNIGHT keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight by Honeywell 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118. For Technical Support, Please call 800-446-6444. www.silentknight.com MADE IN AMERICA FORM# 350118 Rev E © 2013 Honeywell International Inc. INTELLIKNIGHT ACCESSORY SILENT KNIGHT by Honeywell SK-Minimon Intelligent Mini Monitor Module The SK-Minimon addressable mini monitor modules for use with Silent Knight IntelliKnight fire alarm control panels (FACP). The SK-Minimon is designed to be used with pull stations, water flow switches, and other applications requiring dry contact alarm initiation devices. For more information about the IntelliKnight system, or to locate your nearest source, please call 800-328-0103. Description The SK-Minimon is an addressable monitor modules for use with the IntelliKnight fire alarm control panels (FACPs). The SK-Minimon acts as an interface to contact devices, such as waterflow switches and pull stations. The SK-Minimon supports Class B supervised wiring to the load device. Conventional 4 -wire smoke detectors can be monitored for alarm and trouble conditions The SK-Minimon can be mounted in a single gang junction box directly behind the monitored device. Its small size and light weight allow it to be installed without rigid mounting requirements. Features • Single contact monitor • SK-Minimon support for Class B (Style B) contact monitor wiring • Small and lightweight size allows for flexible mounting options • Rotary address switches for fast installation • UL listed Listings UL CSFM FM Specifications Electrical Operating Voltage: 15 — 32 VDC SLC Standby and Alarm Current: 350 pA End -of -Line Resistance: 47K S2 Initiating Device Circuit Wiring Resistance: 1,50052 max SLC Loop Resistance: 40Q max. Wire Length: 6" min. Physical Dimensions: 2.75" W x 1.3" H x 0.5" D Weight: 1.2 oz (37 g) Environmental Operating Temperature: 32°F — 120°F (0°C — 49°C) SK-Minimon Humidity: 10% — 93% non -condensing Compatibility The SK-Minimon is compatible with the following IntelliKnight Systems: 5820XL 5820XL-EVS 5808 5700 5600 (Rev 2.0 or higher) SK-FFT PIN 350133 Rev F © 2015 Honeywell International Inc INTELLIKNIGHT ACCESSORY SK-Minimon Intelligent Monitor Module Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable monitor modules Silent Knight SK-Minimon. The modules shall be UL listed and compatible with Silent Knights IntelliKnight FACPs. The SK-Minimon shall be installed inside a single gang junction box directly behind the monitored unit. Wiring the SK-Minimon Other Devices SILENT KNIGHT by Honeywell This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203)484-7118. For Technical Support, Please Call 800-446-6444. www.silentknight.com FIRE SYSTEM ACCESSORY SILENT KNIGHT by Honeywell Model 5495 Distributed Power Module In an emergency, you need maximum power The 5495 Distributed Power Module by Silent Knight is the most powerful and cost-effective power supply available today. It delivers 6 amps of notification appliance circuit power and built-in synchronization for appliances from System Sensor®,Gentex®, AMSECO®, Wheelock and Faraday — what you need to drive power- hungry components like ADA notification appliances. The 5495's advanced microprocessor design is years ahead of the competition. Its switch mode power supply design is up to 50% more efficient than competitive linear mode power supplies. And, ADA retrofits are easier and less expensive with the 5495 because it integrates into current systems without the costly investment in new components. For the most sophisticated and cost-effective notification power supply available, you need the 5495. Call Silent Knight today for more information at 1-800-328-0103. Model 5495 Distributed Power Module The 5495 is a 6 amp notification power expander that provides its own AC power connection, battery charging circuit, and backup battery for use with fire and security controls such as the Silent Knight Model 5208 Fire Control /Communicator. The 5495 is the cost- effective solution for powering notification appliances required by the Americans with Disabilities Act (ADA). The 5495 has built-in ANSI cadence pattern, which can upgrade older control panels that lack cadence capability. Features • UL Listed for 6 amps of notification power • Power supply's advanced switch mode design reduces damaging heat and manages power up to 50% more efficiently than other systems • Dip switches allow for easy reconfiguration • 24 VDC filtered output voltage • Four power -limited notification outputs; 2 Class A or 4 Class B, or 1 Class A and 2 Class B • Additional continuous auxiliary output • 3 amps per output circuit • 2 inputs; 2 Class B or 2 Class A • Ground fault detector/indicator • Independent trouble relay • AC loss delay option shuts off power to non-essential high -current accessories like magnetic door holders • Built-in synchronization for appliances from System Sensor®,Gentex®, AMSECO®, Wheelock and Faraday • Stand alone operation • Lightweight design adds to ease of installation and reduces shipping costs • Operates with most polarized, UL Listed notification devices • ANSI Cadence pattern output capability built-in Connection to Local Fire Control The 5495 may be connected to a local fire control which utilizes Class A or Class B type notification circuits operating between 9 and 32 VDC. The control panel's notification circuit is connected to one of the inputs on the 5495. The control panel's notification circuit end -of -line resistor is also connected across two terminals on the 5495, which provides supervision between the 5495 and the fire control panel. Polarized audible and/or visual notification devices are then connected to the 5495 signal circuits using the 4.7kS2 end -of -line resistors provided. Since the 5495 draws very little power from the control, it is possible to connect one 5495 to each notification circuit on the control panel and still provide full supervision of the notification circuits all the way back to the control panel. r 1 11 Model 5495 Distributed Power Module Approvals • UL Listed • MEA 429-92-E Vol XII • CSFM 7300-0559:123 • NFPA 72 • OSHPD (CA) OSP-0065-10 (see accessories) PN 350395 Rev G © 2015 Honeywell International Inc. FIRE SYSTEM ACCESSORY Model 5495 Distributed Power Module Model 5495 Block Diagram Signal Circuit Output Signal Circuit Output Signal 1 Input Signal 2 Input (Optional) 120 VAC Local Fire Control Distributed Power Module 5495 Trouble Output (Alternative to notification circuit trouble.) Signal 1 Signal 2 Signal 3 Signal 4 Aux. Power Supervision The 5495 supervises a variety of functions including: • Low AC power • Low battery condition • Earth ground fault • Auxiliary output power limit condition • EOL supervision trouble or power limited condition at an output When a trouble condition occurs, the 5495 creates a trouble condition on the host control signal circuits to which it is connected. the 5495 still maintains the ability to be activated by the host control. In addition, the 5495 provides a Form C trouble relay output as an alternative to using the notification circuit trouble. Electrical Specification AC input: 120 VAC at 2 amps Output: 24 VDC at 6 amps Current: Standby 75 mA Alarm 205 mA Auxiliary power circuit: 1 Notification circuits: 4 Output configuration: • 2 Class A (Style Z) • 4 Class B (Style Y) (1 Class A & 2 Class B) Amps per output circuit: 3.0 (6.0 amps total) Notification circuit output: Alarm Current (for typical voltages) drawn from main panel's notification appliance circuits. 12 VDC 6.5 mA 24 VDC One input circuit - 15 mA; Both input circuits - 30 mA No. of inputs: 2 Input configuration: 2 Class B or 2 Class A Input voltage range: 9 - 32 VDC Battery charging capacity: 35.0 AH Ambient temp.: 32° to 120° F (0° to 49° C) Mechanical Dimensions: 12.25" W x 16" H x 3" D (30.88 cm W x 40.64 cm H x 7.62 D cm) Indicator Lights AC power on : Green Battery trouble: Yellow Ground fault: Yellow Aux trouble: Yellow Output troubles (1-4): Yellow Ordering Information 5495 Distributed Power Module Accessories: SK -SCK Seismic Compliance Kit SILENT KNIGHT by Honeywell This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-7161 Phone: (800) 328-0103, Fax: (203) 484-7118.For Technical Support, please call 800-446-6444. www.silentknight.com Assembled In America COOgR Notification Weatherproof Appliances - Series AH Audibles, AS Audible Strobes, MT Multitone Strobes, RSS Strobes and ET70 Speaker Strobes and Weatherproof Mounting Accessories Description: Designed for life safety, performance and reliability, Cooper Notification's Wheelock cost effective weatherpoof notification appliances include: Weatherproof Appliances Series Strobes Horn Strobes Horns Multitone Horn Strobes Multitone Horns Speaker Strobes Speakers RSSWP ASWP AH-24WP, AH-12WP MTWP MT ET7OWP ET -1010 All strobe models are UL dual listed - meeting both UL1638 and UL1971 requirements. As dual listed appliances, these weatherproof strobes, horn strobes and speaker strobes are listed for outdoor applications under UL 1638 as well as under UL 1971, the Standard for Safety Signaling Devices for Hearing Impaired. With an extended temperature range of —31°F to 150°F (-35°C to 66°C), Wheelock weatherproof appliances meet or exceed UL outdoor test requirements for rain, humidity and corrosion resistance while providing multiple strobe intensity options, including the highest strobe ratings available for area coverage per NFPA 72 strobe spacing tables (up to 185 candela for wall mounting and 177 candela for ceiling mounting). To enable weatherproof mounting, Cooper Notification provides the industry's widest choice of mounting options for surface or unique semi -flush installation. Models are available for surface mounting to Wheelock weatherproof backboxes on walls or ceilings. The optional WP -KIT allows the weatherproof backboxes (IOB, WPBB or WPSBB) to be mounted to a recessed electrical box for concealed conduit installation. For semi -flush installation, the WPA* and WFPA* kits allow a customer to mount the weatherproof appliances to a recessed electrical box without the need for an external weatherproof backbox. See the Backboxes, Plates and Gaskets Table on page three of this document for a summarization of these mounting options and the required accessories. rrel) NEWYORK E5946 151-92-E S5391 S2652 7125-0785:131 (ASWP) 7125-0785:146 (ET7OWP) 7125-0785:156 (MTWP) 7300-0785:154 (RSSWP) APPROVED All models may be synchronized using the Wheelock DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels incorporating the Wheelock Patented Sync Protocol. The horn output of horn strobes can be independently controlled on 2 -wire circuits using the Wheelock patented sync protocol. MTWP horn strobe models are 4 -wire appliances; the strobes can be synchronized while the audible can be connected to a coded fire alarm system or can be set to produce any of eight selectable tones. Features: • Approvals include: UL Standards 1971, 1638, 464 and 1480 California State Fire Marshal (CSFM), New York City (MEA), Factory Mutual (FM), Chicago (BFP) and ULC . See agency approvals by model number on page two of this document • Compliance with the following requirements: NFPA, UFC, ANSI 117.1, OSHA Part 29, 1910.165, ADA • Weatherproof with extended temperature range of —40°F to 150°F (-40°C to 66°C)* • Dual Listed strobe models (UL 1638 and UL 1971) • Industry's highest strobe candela options • Synchronize using the Wheelock Sync Modules or panels with built-in Wheelock Patented Sync Protocol • Models with field selectable tone, dBA and candela settings • Wall or ceiling mounting options • Surface of semi -flush mounting • IN/OUT wiring termination accepting two #12-18 AWG wires at each terminal The series RSSWP, ASWP, AH-24WP, MTWP-2475W, and MT -12/24 have UL / ULC approval down to -40°F. The ET -1010 and ET7OWP have UL approval down to -40°F. The AH-12WP has UL approval down to -31°F. NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERNOTIFICATION.COM OR CONTACT COOPER WHEELOCK FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: • Strobes are designed to flash at 1 flash per second minimum over their UL Listed Regulated Voltage Range. • All candela ratings represent minimum effective Strobe intensity based on UL Standards 1971 and 1638 as indicated in candela ratings table. Wall Mount RSSWP MTWP 1 ASWP ET7OWP Strobe Order Code RSSWP-2475W-FR Red 9013 RSSWP-2475W-FW White 3034 RSSWP-24MCWH-FR Red 5161 RSSWP-24MCWH-FW White 5165 Audible Strobe ASWP-2475W-FR Red ASWP-24MCWH-FR Red ASWP-24MCWH-FW White Multi -tone Strobe MTWP-2475W-FR Red MTWP-2475W-FW White MTWP-24MCWH-FR Red MTWP-24MCWH-FW White Speaker Strobe ET7OWP-2475W-FR Red ET7OWP-2475W-FW White ET7OWP-24185W-FR Red ET7OWP-24185W-FW White ET7OWP-24135W-FR Red ET7OWP-24135W-FW White Ceiling Mount FIRE(' FIRE jar RSSWP MTWP ASWP ET7OWP Strobe RSSWP-2475C-FR Red RSSWP-2475C-FW White RSSWP-24MCCH-FR Red RSSWP-24MCCH-FW White Audible Strobe 9012 -. ASWP-2475C-FR Red 5137 ASWP-2475C-FW White 5140 ASWP-24MCCH-FR Red ASWP-24MCCH-FW White 8420 Multi -tone Strobe 3112 MTWP-2475C-FR Red 5132 MTWP-2475C-FW White 5134 MTWP-24MCCH-FR Red MTWP-24MCCH-FW White 9077 Speaker Strobe 3179 ET7OWP-2475C-FR Red 4885 ET7OWP-2475C-FW White 4891 ET7OWP-24177C-FR Red 4872 ET7OWP-24177C-FW White 4875 ET7OWP-24115C-FR Red ET7OWP-24115C-FW White Order Code 4338 4446 5167 5187 4251 4502 5149 5157 4457 4478 5102 5122 4452 4454 4845 4859 4550 4732 UL Max. Current (Audible) Candela Ratings Series UL 197177°F UL 1638 @�o UL 1638 40°F RSS, ET7OWP and MTWP UL Max Current (Strobe Only) ASWP High Med Low 2475W 30** 180 115 0.138 0.168 0.155 0.150 2475C 15 180 115 0.138 0.168 0.155 0.150 MCWH 135 135 56 0.300 0.355 0.340 0.335 185 185 77 0.420 0.480 0.465 0.460 MCCH 115 115 47 0.300 0.355 0.340 0.335 177 177 73 0.420 0.480 0.465 0.460 24185 185 185 77 0.420 **Wall mount rating only 24177 177 177 73 0.420 UL Max. Current (Audible) MTWP/MT 24 VDC MT 12 VDC dBA HI STD HI STD Horn 0.108 0.044 0.177 0.034 Bell 0.053 0.024 0.095 0.020 March Time 0.104 0.038 0.142 0.034 Code 3 Horn 0.091 0.035 0.142 0.034 Code 3 Tone 0.075 0.035 0.105 0.021 Slow Whoop 0.098 0.037 0.142 0.035 Siren 0.104 0.036 0.152 0.030 Hi/Lo 0.057 0.025 0.114 0.026 Wall or Ceiling Mount MT ET -1010 Audible AH-24WP-R AH-12WP-R 1 AH Order Code Red 7416 Red 7415 Horn MT -12/24-R Red 5023 Speaker ET -1010-R ET -1010-W Red 3135 White 3137 UL Max. Current 1 AH 1/8 124 VDC 12 VDC High (99) dBA 0.080 0.192 Med (95) dBA 0.043 0.108 Low (90) dBA 0.021 0.058 UL Reverberant dBA @ 10 Feet Watts 1/8 1/4 1/2 1 2 4 8 ET -1010 77 80 83 86 87 92 94 ET7OWP 78 81 84 87 90 93 95 Model Number Agency Approvals Strobe UL MEA CSFM FM BFP RSSWP-2475 X X X X - RSSWP-24MCWH X - X - - RSSWP-24MCCH X - X - - Audible Strobe ASWP-2475 X X X X X ASWP-MCWH X - X - - ASWP-MCCH X - X - - Multitone Strobe MTWP-2475 X X X X - MTWP-MCWH X - X - - MTWP-MCCH X - X - - Horns/Audibles AH-24WP X X X X X AH-12WP X X X X X MT -12/24 X X X X X Speaker Strobe ET7OWP-2475 X - X X - ET7OWP-185 X - X X - ET7OWP-177 X - X X - ET7OWP-115 X - X X - ET7OWP-135 X - X X - Mounting Accessories a WFP WFPA Gasket Kit Order Code WP -KIT 4486 Flush Plates WFPA-R Red 4698 WFPA-W White 4701 WFP-R Red 4696 WFP-W White 4697 Backboxes 10B -R* Red 5046 10B -W* White 5047 WPSBB-R* Red 9751 WPSBB-W* White 3033 WPBB-R* Red 9014 WPBB-W" White 4692 WBB-R Red 2959 WBB-W White 2960 Wiring Diagrams MS* II IOB WPSBB WPBB WBB Mounting Options: Backboxes, Plates, Gasket Kits Surface Mount Flush Mount Exposed Conduit Concealed Conduit RSSWP Strobes WPSBB WPSBB + WP -KIT WFP ET7OWP Speaker Strobes 10B IOB + WP -KIT WFP ASWP Horn Strobes WPBB WPBB + WP -KIT WFPA AHWP Horns WBB - WFP ET -1010 Speakers WBB - WFP MTWP Multitone Horn Strobes IOB 10B + WP -KIT WFP Multitone Horn 10B 10B + WP -KIT WFP *I0B, WPSBB and WPBB models include weep holes and plug in the event that moisture may have entered the appliance SERIES MTWP AUDIBLE APPLIANCE AND STROBE OPERATE IN UNISON. RED AND BLACK SHUNT -WIRES ARE SUPPLIED. FROM PRECEDING APPLIANCE OR FACP STROBE AUDIBLE + TO NEXT APPLIANCE - OR EOLR SERIES RSSWP, ASWP, AHWP, MTWP AND MT -12/24 APPLIANCES FROM PRECEDING APPLIANCE OR FACP TO NEXT APPLIANCE OR EOLR SERIES MTWP APPLIANCES SYNCHRONIZED STROBE OPERATION WITH CODED FACP NACO1 FACP NAC 02 0 Sync 0 0,-1— Module or 0 PS Power Supply MTWP 0 0 Strobe Circuit Audible Circuit } Note: Strobe circuit requires constant voltage. SERIES RSSWP/ASWP APPLIANCES SYNCHRONIZED W/ DSM MODULE SINGLE CLASS "A" NAC CIRCUIT STROBE NAC CIRCUIT OUT DSM TROBE NAC CIRCUIT RETURN Note: Models are available in Red or White. Contact Customer Service for Order Code and Delivery. #Refer to Data Sheet S7000 for Mounting Options NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Cooper Wheelock Inc. dba Cooper Notification standard terms and conditions. • ARCHITECTS AND ENGINEERS SPECIFICATIONS General Weatherproof notification appliances shall be UL listed for outdoor use. Weatherproof Strobe appliances shall be listed under UL Standard 1638 (Standard for Visual Signaling Appliances) for Indoor/Outdoor use and UL Standard 1971 (Standard for Safety Signaling Devices for Hearing Impaired). The appliances shall be available for optional wall mounting or ceiling mounting to weatherproof backboxes using either exposed conduit or concealed conduit, or semi -flush mounting to a recessed electrical box in walls or ceilings using Wheelock mounting accessories. Weatherproof Strobes Weatherproof Strobe appliances shall produce a minimum flash rate of 60 flashes per minute over the UL Regulated Voltage Range of 16 to 33 VDC and shall incorporate a Xenon flashtube. The weatherproof strobes shall be available with UL 1971 candela ratings up to 185 cd for wall mounting and 177 cd for ceiling mounting. UL 1638 candela ratings up to 180 cd at 77°F shall be available. The strobes shall operate over an extended temperature range of —40°F to 150°F (-40°C to 66°C) and be listed for maximum humidity of 95% RH. Strobe inputs shall be polarized for compatibility with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). WeatherproofAudibles and Audible/Strobe Combinations Weatherproof horns and multitone audibles shall be listed for Indoor/Outdoor use under UL Standard 464. The horns shall be able to produce a continuous output or a temporal code -3 output that can be synchronized. The horns shall have at least 3 sound level settings. Horn/Strobe combinations shall be able to be synchronized on a single NAC. Multitone audibles shall be able to produce 8 distinct tones selectable by dip switch and shall have at least 2 sound level settings. Multitone Audible/Strobe combinations shall have independent inputs for the audible and strobe. The strobes shall be able to be synchronized. The audibles shall be able to be coded when operated on a separate NAC. Weatherproof Speakers and Speaker/Strobes Weatherproof speakers and speaker/strobes shall be listed for Indoor/Outdoor use under UL Standard 1480. All speakers shall provide field selectable taps for 1/8W to 8W operation for either 25 VRMS or 70 VRMS audio systems and shall incorporate a sealed back construction for extra protection and improved audibility. Speakers without strobes shall be Wheelock Series ET -1010. They shall be listed to produce up to 94 dBA and shall incorporate a vandal resistant grille design. Speaker with strobes shall be Wheelock Series ET7OWP. They shall be available for surface or semi -flush mounting to walls or ceilings and shall be listed to produce up to 93 dBA. Synchronization Modules When synchronization of strobes or temporal code -3 audibles is required, the appliances shall be compatible with the Wheelock Series DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels with built-in Wheelock Patented Sync Protocol. The strobes and audibles shall not drift out of synchronization at any time during operation. Series ASWP audibles and strobes shall be able to be synchronized on a 2 -wire circuit with the ability to silence the audible if required. The strobes on Series MT multitone audible/strobe appliances shall be able to be synchronized and shall be able to be operated on a separate circuit from the audibles while the audible circuit is connected to a coded or continuous NAC. Weatherproof Mounting Accessories Weatherproof mounting options shall include surface mounting or semi -flush mounting to walls or ceilings. Surface mounted appliances shall mount to Wheelock IOB, WBB, WPBB or WPSBB weatherproof backboxes using either exposed conduit or concealed conduit. For concealed conduit the weatherproof backbox shall be mounted to a recessed electrical box with Wheelock's WP -KIT to provide a weatherproof seal for the electrical box. Semi -flush mounted appliances shall mount to a recessed electrical box using Wheelock WFP or WFPA flush plates to provide a weatherproof seal between the electrical box and the appliance. NEM Member WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY S9004 WP 11/12 NJ Location 273 Branchport Ave. Long Branch, NJ 07740 P: 800-631-2148 F: 732-222-8707 www.coopernotification.com Cooper Notification is Wheelock° 3 lie SAFEPATM WAO ? COOPER Notification D 7Witho .it Comments Q Ac' ivot eo 1:1 R.e4 0 Pe: The Attacned Letter These plans have ::4iewed by -rhe Tukwila Fire �:,en iort 6urecv -0formance vv tr current City �farils. Accep:1 , *bject to errors and omissions which ao violations of adopted n tiaras and orci,��.,nce=.-* • • ‘f!. responsibiiicy for the ' pu cy of des, , : •with the designer. to these drawings after u is i,i:.t'; ac `et ince and will require a I csubinarsec: r a'vires ` subsequent approval. Fl gal ac:cepta;,cc: lbteci: co dela rest and Inspection by The Tukwila Flee 2 v r!tipn Bureau. Date: /-.)N4 -1 Co By: / ,i ( . P JKWILA FIRE DEPARTMENT Pa- call 206-575-4407 and givp this nre Permit Na. f(D- F -or) and exact address for shut- down hutdown or restoration approval. NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to Commencement of Acceptance Testing of any Fire Alarm and Detection Syst3ms. Failure of test result In a Re -inspection Fee and termination of the testing