Loading...
HomeMy WebLinkAboutPP - 17348 SOUTHCENTER PKWY - MULTIPLE - PERMITS AND PLANS17348 SOUTHCENTER PKWY ASSOCIATED PERMITS 12-F-206 91241 01-F-250 866071 01-S-211 855295 91-S-317 46.1ttliwz4tv SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** Site Address: 17 24 3 5cp rrt1 c tNTA2 Rmm Tenant Name: 'S I CO 1 S Property Owner's Name: TN) 6 (QHS Mailing Address: 3(DC-3 +?)-4LL1 P) r? -c44 PAID SEP 2 2111 12.9l•<-1 TUKVVILA FIRE King Co. Assessor's TaxNo.: 26230 ///O Suite Number: Floor: New Tenant? .0- Yes ❑ - No CcUUvUS City CONTACT PERSON -if there are questions about the submittal. Name: M 11Z14At-WAl-( cy4 4/32 2F State Zip Day Telephone: Z S3 Z F7 37 7 Company Name: en SaUA SU, ,�/ a is►s I _ , �► Mailing Address: CX 73/22.7 Popo ftp WfC 9e 372 E-mail Address: h'\ i Xet-, e G 2.51. S- 1v1S(J(, cQ V) City SZ3-3 Zef ' 37,y te Zip Fax Number: Valuation of Project (contractor's bid price): $ 9i /9'] Scope of Work (please provide detailed information): 1N S1/ui knonl cl' NAJ Fr IaLP�l'�l C° CL shicA perg c , pull Srl� S, f•Icn►I-t:41>`►G ocra ANb 42N/ / s7R465; .s?mss • PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: l ) Signature: 44/NJ_ l Date: `/ /' tZ Print Name: MI a- ApJNAW Day Telephone: ZS3 2.W-3-2 `3-2 Plan Permit App.doc 5/14/10 TFD FP Form 8 SILENT KNIGHT 5820XL Calculations panel 'ID; Location.: 5820XL SPRINKLER RISER ROOM 11-3ya Sc PKwY global Prgject values. '•roject Name: BIG LOTS TUKWILA Project ID: Prepared By: Dater: 9/11/2012 686M MIKE HANNAH Standby Hours:; Alarm Mins:. 24 5 Derating Factor:l Voltage Drop Warning Threshold % . 1.2 10 Model: 5820XL Add. Fire/Mem Volts:. 24 VDC ntroi.Pariei Max NAC -Current: 3:0 Amps MaxPanel Current: 5.0 Amps 5895XL "$65-4 5865-3 5880, SD505-SSB SD505aRB SD-Duct 5883 Aux Powe Circuit Name 5820XL CTRL Panel Addrsbl SLC Devices SLC Loop Expander LCD Remote Annunc Current Draw Standby -,-Alarm 0.140 0.260 0.004 0.004 Serial/Parallel Module Power Expander LED Annunciator (4G) Annunciator (3G) LED Driver Module Sounder Base Relay Base Duct Hsg w/Relay Relay Module 1 # of NAC's Used 0.000 0.000 0.020 0.025 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 dire AWG T®.e Ohms Per Length(ft) Adtual Volts © 1000 Ft. One-Wa; Ohms EOL %Drop PQM-I/O #1 NAC -1 0.000 0.910 #14 Solid 2.52 0.£0 20.40. 0.00% PGM -,110 #2! NAC -2 0.000 0.546 #14 Solid 2.52 0.00 20.40 0.00% PGM -1/0-#3 NAC -3 0.000 0.546 #14 Solid 252 0:00 20 0,00% i''GM-1/O,44-. NAC -4 0.000 1.052 #14 Solid 2.52 :. 0.00 2040 0.00% PGM -1/a#5; SPARE 0.000 0.000 #14 Solid 2.52 0.00 20.40 0.00% PGM -170# #6 SPARE 0.000 0.000 #14 Solid 2.52 0.00 20.40 0.00% Total Standby,Current (Amps')° 0.164 3.343 Total Alarm Current (Amps) Standby Time In Hours. 24 0.083 Alarm Time in Minutes/60 (5 .Mins) Total Standby.AH Required° 3:932 0.279 Total Alarm AH Required Total Combined AH Required, 4.21 Multiply icy- The Derating Factor 1.21. Minimum Battery AmpHours Required 5.05 Command Shortcuts Configure Circuits *1 Note: A value must be entered if you have selected any NAC circuits as Aux Power. Print Page NAC Circuit LoadNoltage Drop Calculations Date: 9/11/2012 Job Number: 686M Job Name: Big Lots Tukwila NAC Circuit: NAC -1 Device Type 1 Qty. 1 Amps Total P2 Series Horn/Strobe 15cd Horn/Strobe - medium setting typ. 2 0.069 0.138 30cd Horn/Strobe 0.097 0.000 75cd Horn/Strobe (interior or W.P.) 0.157 0.000 95cd Horn/Strobe 3 0.182 0.546 110cd Horn/Strobe 0.201 0.000 115cd Horn/Strobe 0.210 0.000 S Series Strobes 15cd Strobe 2 0.066 0.132 30cd Strobe I 1 i 0.094 0.094 75cd Strobe (Interior or W.P.) 0.158 0.000 95cd Strobe 0.181 0.000 110cd Strobe 0.202 0.000 115cd Strobe 0.210 0.000 MH Mini Horn (temporal - low 76db) 1 0.014 0.000 0.000 MB -G10 -24-R W.P. 10" Alarm Bell I 0.060 0.000 0.000 0.000 0.000 0.000 CH Series Chime/Strobe 15cd Chime/Strobe - Temporal low setting typ. 0.071 0.000 30cd Chime/Strobe 0.097 0.000 75cd Chime/Strobe 0.156 0.000 110cd Chime/Strobe 0.200 0.000 Chime only 0.050 0.000 0.000 0.000 0.000 0.000 Combined Device Totals 8 1 0.910 Voltage Drop - Wire Size (Wire length doubled) j Feet j Resistance) Drop AWG 16 - 5.29 Ohms/1000 ft I 0.000 I 0.000 AWG 14 - 3.26 Ohms/1000 ft 325 2.119 I 1.928 AWG 12 - 2.05 Ohms/1000 ft I 0.000 j 0.000 NAC Circuit LoadNoltage Drop Calculations Date: 9/11/2012 Job Number: 686M Job Name: Big Lots Tukwila NAC Circuit: NAC -2 Device Type I Qty. Amps Total P2 Series Horn/Strobe 15cd Horn/Strobe - medium setting typ. 0.069 0.000 30cd Horn/Strobe 0.097 0.000 75cd Horn/Strobe (interior or W.P.) 0.157 0.000 95cd Horn/Strobe 3 0.182 0.546 110cd Horn/Strobe 0.201 0.000 115cd Horn/Strobe 0.210 0.000 S Series Strobes 15cd Strobe 0.066 0.000 30cd Strobe 0.094 0.000 75cd Strobe (Interior or W.P.) 1 0.158 0.000 95cd Strobe 0.181 0.000 110cd Strobe 0.202 0.000 115cd Strobe 0.210 0.000 MH Mini Horn (temporal - low 76db) 0.014 0.000 1 0.000 MB -G10 -24-R W.P. 10" Alarm Bell 0.060 ' 0.000 0.000 0.000 0.000 0.000 CH Series Chime/Strobe 15cd Chime/Strobe - Temporal low setting typ. 0.071 0.000 30cd Chime/Strobe 0.097 0.000 75cd Chime/Strobe 0.156 0.000 110cd Chime/Strobe 0.200 0.000 Chime only 0.050 0.000 0.000 0.000 0.000 0.000 Combined Device Totals 3 ; I 0.546 Voltage Drop - Wire Size (Wire length doubled) I Feet Resistance; Drop AWG 16 - 5.29 Ohms/1000 ft 1 0.000 1 0.000 AWG 14 - 3.26 Ohms/1000 ft 185 1.206 0.659 AWG 12 - 2.05 Ohms/1000 ft 0.000 0.000 NAC Circuit LoadNoltage Drop Calculations Date: 9/11/2012 Job Number: 686M Job Name: Big Lots Tukwila NAC Circuit: NAC -3 Device Type Qty. Amps Total P2 Series Horn/Strobe 15cd Horn/Strobe - medium setting typ. 0.069 0.000 30cd Horn/Strobe 0.097 0.000 75cd Horn/Strobe (interior or W.P.) 0.157 0.000 95cd Horn/Strobe 3 0.182 0.546 110cd Horn/Strobe 0.201 0.000 115cd Horn/Strobe 0.210 0.000 S Series Strobes 15cd Strobe 0.066 0.000 30cd Strobe 0.094 0.000 75cd Strobe (Interior or W.P.) 0.158 0.000 95cd Strobe 0.181 0.000 110cd Strobe 0.202 0.000 115cd Strobe 0.210 0.000 MH Mini Horn (temporal - low 76db) I 0.014 ' 0.000 0.000 MB -G10 -24-R W.P. 10" Alarm Bell j 0.060 0.000 0.000 1 0.000 I I 0.000 1 0.000 CH Series Chime/Strobe 15cd Chime/Strobe - Temporal low setting typ. 0.071 0.000 30cd Chime/Strobe 0.097 0.000 75cd Chime/Strobe 0.156 0.000 110cd Chime/Strobe 0.200 0.000 Chime only 0.050 0.000 0.000 _1 0.000 I 0.000 0.000 Combined Device Totals 3 j 0.546 Voltage Drop - Wire Size (Wire length doubled) ' Feet j Resistance! Drop AWG 16 - 5.29 Ohms/1000 ft j 0.000 ! 0.000 AWG 14 - 3.26 Ohms/1000 ft 1 145 , 0.945 0.516 AWG 12 - 2.05 Ohms/1000 ft J 0.000 0.000 NAC Circuit LoadNoltage Drop Calculations Date: 9/11/2012 Job Number: 686M Job Name: Big Lots Tukwila NAC Circuit: NAC-4 Device Type I Qty. Amps Total P2 Series Horn/Strobe 15cd Horn/Strobe - medium setting typ. 1 0.069 0.069 30cd Horn/Strobe 0.097 0.000 75cd Horn/Strobe (interior or W.P.) 3 0.157 0.471 95cd Horn/Strobe 1 0.182 0.182 110cd Horn/Strobe 0.201 0.000 115cd Horn/Strobe 0.210 0.000 S Series Strobes 15cd Strobe 5 0.066 0.330 30cd Strobe 0.094 0.000 75cd Strobe (Interior or W.P.) 0.158 0.000 95cd Strobe 0.181 0.000 110cd Strobe 0.202 0.000 115cd Strobe 0.210 0.000 MH Mini Horn (temporal - low 76db) 0.014 0.000 0.000 MB-G10-24-R W.P. 10" Alarm Bell 0.060 0.000 0.000 0.000 0.000 0.000 CH Series Chime/Strobe 15cd Chime/Strobe - Temporal low setting typ. 0.071 0.000 30cd Chime/Strobe 0.097 0.000 75cd Chime/Strobe 0.156 0.000 110cd Chime/Strobe 0.200 0.000 Chime only 0.050 0.000 0.000 0.000 0.000 0.000 Combined Device Totals I 10 I ( 1.052 Voltage Drop - Wire Size (Wire length doubled) I Feet j Resistance) Drop AWG 16 - 5.29 Ohms/1000 ft I 0.000 I 0.000 AWG 14 - 3.26 Ohms/1000 ft 235 I 1.532 1.612 AWG 12 - 2.05 Ohms/1000 ft 0.000 0.000 BATTERY CALCULATIONS JOB NUMBER: 686M JOB NAME: BIG LOTS APPLICATION: SNAC Panel DATE: 09/19/12 REV NO: 0 REV DATE: Device/Description Qty Supervision Qty Alarm Amps/Device Total Amperage Amps/Device Total Amperage Main Circuit Board - HPF24S8 1 0.091 0.091 1 0.145 0.145 NAC -1 1 1 0.91 NAC -2 1 1 0.546 NAC -3 1 1 0.546 NAC -4 1 1 1.052 Amperes Hours Total Amp-Hrs Total Supervisory Current 0.091 24 2.2 Battery Charging Rate (Amp-Hr/Hr) Total Time to Recharge (Hrs) N/A Stand -By Battery Requirement Total Amp-Hrs 2.5 Battery De -Rating Plus: 20% Total Amp-Hrs 3.0 Battery Supplied Total Amp-Hrs 8.0 Comments: Page 1 Rev. 08/25/03 Form # QAF 4.003 Amperes Minutes : :.. . Total Amp-Hrs Total Alarm Current 3.199 5...:::: 0.3 Battery Charging Rate (Amp-Hr/Hr) Total Time to Recharge (Hrs) N/A Stand -By Battery Requirement Total Amp-Hrs 2.5 Battery De -Rating Plus: 20% Total Amp-Hrs 3.0 Battery Supplied Total Amp-Hrs 8.0 Comments: Page 1 Rev. 08/25/03 Form # QAF 4.003 NAC Circuit LoadNoltage Drop Calculations Date: 9/19/2012 Job Number: 686M Job Name: Big Lots Tukwila NAC Circuit: NAC -1 Device Type Qty. Amps Total P2 Series Horn/Strobe 15cd Horn/Strobe - medium setting typ. 2 0.069 0.138 30cd Horn/Strobe 0.097 0.000 75cd Horn/Strobe (interior or W.P.) 0.157 0.000 95cd Horn/Strobe 3 0.182 0.546 110cd Horn/Strobe 0.201 0.000 115cd Horn/Strobe 0.210 0.000 S Series Strobes 15cd Strobe 2 0.066 0.132 30cd Strobe 1 0.094 0.094 75cd Strobe (Interior or W.P.) 0.158 0.000 95cd Strobe 0.181 0.000 110cd Strobe 0.202 0.000 115cd Strobe 0.210 0.000 MH Mini Horn (temporal - low 76db) 0.014 0.000 0.000 MB -G10 -24-R W.P. 10" Alarm Bell 0.060 0.000 0.000 0.000 0.000 0.000 CH Series Chime/Strobe 15cd Chime/Strobe - Temporal low setting typ. 0.071 0.000 30cd Chime/Strobe 0.097 0.000 75cd Chime/Strobe 0.156 0.000 110cd Chime/Strobe 0.200 0.000 Chime only 0.050 0.000 0.000 0.000 0.000 0.000 Combined Device Totals 8 0.910 Voltage Drop - Wire Size (Wire length doubled) Feet Resistance Drop AWG 16 - 5.29 Ohms/1000 ft 0.000 0.000 AWG 14 - 3.26 Ohms/1000 ft 325 2.119 1.928 AWG 12 - 2.05 Ohms/1000 ft 0.000 0.000 NAC Circuit LoadNoltage Drop Calculations Date: 9/19/2012 Job Number: 686M Job Name: Big Lots Tukwila NAC Circuit: NAC -2 Device Type Qty. Amps Total P2 Series Horn/Strobe 15cd Horn/Strobe - medium setting typ. 0.069 0.000 30cd Horn/Strobe 0.097 0.000 75cd Horn/Strobe (interior or W.P.) 0.157 0.000 95cd Horn/Strobe 3 0.182 0.546 110cd Horn/Strobe 0.201 0.000 115cd Horn/Strobe 0.210 0.000 S Series Strobes 15cd Strobe 0.066 0.000 30cd Strobe 0.094 0.000 75cd Strobe (Interior or W.P.) 0.158 0.000 95cd Strobe 0.181 0.000 110cd Strobe 0.202 0.000 115cd Strobe 0.210 0.000 MH Mini Horn (temporal - low 76db) 0.014 0.000 0.000 MB -G10 -24-R W.P. 10" Alarm Bell 0.060 0.000 0.000 0.000 0.000 0.000 CH Series Chime/Strobe 15cd Chime/Strobe - Temporal low setting typ. 0.071 0.000 30cd Chime/Strobe 0.097 0.000 75cd Chime/Strobe 0.156 0.000 110cd Chime/Strobe 0.200 0.000 Chime only 0.050 0.000 0.000 0.000 0.000 0.000 Combined Device Totals 3 0.546 Voltage Drop - Wire Size (Wire length doubled) Feet Resistance Drop AWG 16 - 5.29 Ohms/1000 ft 0.000 0.000 AWG 14 - 3.26 Ohms/1000 ft 185 1.206 0.659 AWG 12 - 2.05 Ohms/1000 ft 0.000 0.000 NAC Circuit LoadNoltage Drop Calculations Date: 9/19/2012 Job Number: 686M Job Name: Big Lots Tukwila NAC Circuit: NAC -3 Device Type Qty. Amps Total P2 Series Horn/Strobe 15cd Horn/Strobe - medium setting typ. 0.069 0.000 30cd Horn/Strobe 0.097 0.000 75cd Horn/Strobe (interior or W.P.) 0.157 0.000 95cd Horn/Strobe 3 0.182 0.546 110cd Horn/Strobe 0.201 0.000 115cd Horn/Strobe 0.210 0.000 S Series Strobes 15cd Strobe 0.066 0.000 30cd Strobe 0.094 0.000 75cd Strobe (Interior or W.P.) 0.158 0.000 95cd Strobe 0.181 0.000 110cd Strobe 0.202 0.000 115cd Strobe 0.210 0.000 MH Mini Horn (temporal - low 76db) 0.014 0.000 0.000 MB -G10 -24-R W.P. 10" Alarm Bell 0.060 0.000 0.000 0.000 0.000 0.000 CH Series Chime/Strobe 15cd Chime/Strobe - Temporal low setting typ. 0.071 0.000 30cd Chime/Strobe 0.097 0.000 75cd Chime/Strobe 0.156 0.000 110cd Chime/Strobe 0.200 0.000 Chime only 0.050 0.000 0.000 0.000 0.000 0.000 Combined Device Totals 3 0.546 Voltage Drop - Wire Size (Wire length doubled) Feet Resistance Drop AWG 16 - 5.29 Ohms/1000 ft 0.000 0.000 AWG 14 - 3.26 Ohms/1000 ft 145 0.945 0.516 AWG 12 - 2.05 Ohms/1000 ft 0.000 0.000 NAC Circuit LoadNoltage Drop Calculations Date: 9/19/2012 Job Number: 686M Job Name: Big Lots Tukwila NAC Circuit: NAC -4 Device Type Qty. Amps Total P2 Series Horn/Strobe 15cd Horn/Strobe - medium setting typ. 1 0.069 0.069 30cd Horn/Strobe 0.097 0.000 75cd Horn/Strobe (interior or W.P.) 3 0.157 0.471 95cd Horn/Strobe 1 0.182 0.182 110cd Horn/Strobe 0.201 0.000 115cd Horn/Strobe 0.210 0.000 S Series Strobes 15cd Strobe 5 0.066 0.330 30cd Strobe 0.094 0.000 75cd Strobe (Interior or W.P.) 0.158 0.000 95cd Strobe 0.181 0.000 110cd Strobe 0.202 0.000 115cd Strobe 0.210 0.000 MH Mini Horn (temporal - low 76db) 0.014 0.000 0.000 MB -G10 -24-R W.P. 10" Alarm Bell 0.060 0.000 0.000 0.000 0.000 0.000 CH Series Chime/Strobe 15cd Chime/Strobe - Temporal low setting typ. 0.071 0.000 30cd Chime/Strobe 0.097 0.000 75cd Chime/Strobe 0.156 0.000 110cd Chime/Strobe 0.200 0.000 Chime only 0.050 0.000 0.000 0.000 0.000 0.000 Combined Device Totals 10 1.052 Voltage Drop - Wire Size (Wire length doubled) Feet Resistance Drop AWG 16 - 5.29 Ohms/1000 ft 0.000 0.000 AWG 14 - 3.26 Ohms/1000 ft 215 1.402 1.475 AWG 12 - 2.05 Ohms/1000 ft 0.000 0.000 9004 NE 132 Place Kirkland, WA 98034 Office 425-825-0778 Fax 425-823-3796 PRO ALARMS PLUS, INC. Project: Marshall's Tenant Improvement 17348 - Southcenter Parkway Tukwila, Washington 98188 Battery Calculation Worksheet This scope of work is a tenant improvement to the fire alarm system. This worksheet is for the new signal expander power supply and the signal devices that it powers. Qty Model # Supervised Current (mA) Alarm Current (mA) 1 SK5495 power supply 75 175 1 D570S Horn strobe - 15 cd 0 64 2 D573S Horn strobe - 30 cd 0 196 11 D574S Horn strobe - 75 cd 0 1639 1 D572S Horn strobe - 110 cd 0 177 3 D544S Strobe - 15 cd 0 150 2 D547S Strobe - 75 cd 0 266 Subtotal 75 2667 Total hours X24 X.083 Subtotal 1800 221.4 Safety Factor 10% +180 +22.1 Total 1980 243.5 Total Current Required 2224mA or 2.22 amps Battery sized used : 2ea 7 amp batteries 6" FL 90°BEND ID' CIP 10' CIP 10"CIP CIP LIP SEE DETAIL A r—CONCRETE VALVE PIT 10" FL X MJ ADAPTER I0.X IO"X 6' FL TEE 6" FL CHECK VALVE 6X2Yi X2YYX2Y"X2Y. FIRE DEPT CONNECTION 2)" CIP ID" CITY MAIN 10" FL PIV IO" FL CHECK VALVE —10" FL X MI ADAPTER J0�1( !Cr TAPPING SLEEVE $ VALVE SIO" CITY MAIN EXISTING PIT DETAIL A OWED - SEE UTILITY VAULT DETAIL UTILITY VAULT CO.' 612 LA W/612 TL 42E TOP SECTION P N VERTICAL BENDS WAY BE REOU1RED EACH EN) OF VAULT TO MATCH EX. p EX. CURB REMOVE EX.90° BEND AND CHECK VALVE AND CONNECT -e\ TO VERTICAL 10° BEND. FL.PP- EX. F D C TO REMAIN —3D IO"CIP RED ROBIN I�u Pyr PIT —PIT 4�' INSTALL BLIND FLG.ON xt4=P EX TEE 0------ EX PIV TO REMAIN REMOVE EX. CHECK VALVE' REPLACE W 10" O.I. PIPE.' P. E. x P.E AND 2- D.I FLANGE 1 ADAPTERS. E -Z FLANGE SERIES 1000 VAULT NO. 2 , PLAN- VIEW SCALE I"=10' BEST e_ PIY EIISTING VAULT 618" PROPOSED UTILITY �� VAULT (SEE DETAIL) 3 ISLAND J �lam_ 00 1 6. I01 I "— FIRE CONNECTION 10" D I ID" COUPLING I EX. ID"W VAULT NO. 1 PLAN VIEW SCALE: I": 10' SO 10" CIP NOTES: 1. ALL PIPING SHALL BE IN ACCORDANCE WITH THE CITT OF TUKWILA STANDARD SPECIFICATIONS 2. All RESTORATION, CURBS, LANDSCAPING, ASPHALT ECT, SHALL BE REMOVED AND RESTORED TO ITS ORIGINAL CONDITION 3"W PAVILION OUTLET CENTER THE BON i Lim--1o•cIP rl NEW DOUBLE DETECTOR CHECK VAULT NO. 2 , f� tv'1 10' CIP 8 CIP 10' CIP Ig4.1" CIP 8' CIP 2 8' CIP IO" COUPLING 10"x 6" TEE, MJ *AU 6" 90' BEND, MJ.{ MJ. UTILITY VAULT CO. 612 LA,W/612TL•42E TOP SECTION 25 L F.- 6" D I PIPE REMOVE EX. 90°BEND AND CHECK VALVE AND CONNECT TO VERTICAL 90° BEND, FL. POWER VAULTS VERTICAL BENDS MAY BE REQUIRED EACH END OF VAULT TO MATCH EX PIPE BLOCK AS REQUIRED 10" BATE VALVE * bOX POWER VAULT 2 STl DOORS INSTALL BLIND FL6 ON TEl EX. PIV TO REMAIN REMOVE EX CHECK VALVE. REPLACE WITH 10" D.I PIPE P.E X P E AND 2-0.I FLANGE ADAPTERS. El- FLANGE SERIES 1000 EX FIRE DEPT CONNECTION - TO REMAIN . I VAULT NO. 3 PLAN VIEW SCALE: I" =10' I0"GATE VALVE t BOX oto NEE SDNI sea alto c�NO NO a �l-ALIGN CORNER OF VAULT WITH EX SIDEWALK SEE UTILITY VAULT DETAIL '6" 90°BEND MJ x MJ. 1011(6" TEE MJ xMJ Sp VERTICAL BENDS MAY BE REQUIRED EACH END OF VAULT TO MATCH EX. PIPE ��f\4 FIRE DEPARTMENT CONNECTION TO REMAIN D_ ioa VAULT NO. 4 PLAN VIEW SCALE I". 10' NEW DOUBLE DETECTOR CHECK VAULT N0.4 6" CHECK VALVE FLxFL. SEE SITE PLAN FOR CONTINUATION 1; UTILITY VAULT CO. G12 LA ,W /612-42 E TOP SECTION 8" RISER W/42" DIA FRAME t LID MARt(ED"WATER" 6" COUPLING TO FIRE DEPARTMENT� CONNECTION IN EX. VAULT CONTRACTOR SHALL VERIFY PIPING IN VAULT. REMOVE EX. 90° AND CHECK VALVE AND CONNECT TO VERTICAL 90° BEND. FL INSTALL BLIND FLANGE ON TEE EX P I V. TO REMAIN REMOVE EX CHECK VALVE REPLACE WITH 10" D I. PIPE P E x P.E AND 2' D I FLANGE ADAPTERS. E -Z FLANGE SERIES 1000 6'-0" UTILITY VAULT DETAIL NO SCALE NOV 08 1991 10" COUPLING HERSEY/GRINNELL MODEL DDC -II ID" DOUBLE CHECK DETECTOR BACKFLOW PREVENTION ASSEMBLY_ DESIGNED DRAWN T.D.B. CHECKED R. D S. REVISED DOUBLE CK. VALVE VAULTS N0.3 $ 4 ADDED VAULT NO.2 LA.B R 11-4-91 SYMBOL REVISION •r APPROVED DATE Horton Dennis ff Associates, Inc, Consulting Engineers KIRKLAND, WASH INGTON TRAMMEL CROW COMPANY APPROVED DAT 5-16-91 SCALE I"• 100' F • NO PARKWAY PLAZA NORTH WATER UPGRADES JOB NO. 8873.00 SHEET NO 2 2 OF 4- a • 5- ,t 7 Y 3 -� a 3s -i.etsy 8 4 4 • • - • i • r> s A s r 4 3 i 3 • • F T 'T- --ter'•-.3` T --A • • s i' _• 4. 'O� y 1 1 �1 11 1 I 1 { • Y 0 • a --------------- -- --- • t • r • 4 f ►f 1:x i 4 4. • • 4.1 tit ito re - _4 F • 4 T t f � r., 21- • It.- 4- J F 0 4 • OFFICES PzuctaEr..4r5 14.5' re - • IQ 4 • • 1. • i • i Y • 3 - 4 F 4- L •_.• -75 i`- 1 'r1- e -4 34 T s - - - i 4- 7 No. • •• 4 ;R • - ■ • - 4- • s Y 0 • • 4, • a i • 3 Eye Rod Hangers • • ; s Hanger Rings / Anchors- UL Listed & FM Approved - tianger Rods / Fasteners. Comply with NFPA 13 • Machine Thread Rods Only - Finisher 0 Standard CornpOnents 0 All Galvanized Components • • - • 44. • 0 No -131 for Wood 2 0 tor "%*,;47.0"' • • 0 2.4 • • • 4. 3 NB- r • • • - Components _ 1. Eye Rod 2. Flat Washer - • 3; Hex Head Cap Screw 4 Adjustable Hanger 8.- Lock Washer • • 0 No.132 for Brick 0 No 133 for Concrete 1 • • • 5 44 • 77S- 77 e2 • • 00.r 0 • CI No 134 for Steel NFPA 13 sets minimum distances for placement of fasteners above the bottom of beams or joists _ Wood. 21V (64 mm) minimum for branch lines (pips sizes 2" & smaller) ---, - . 3' (76 mm) minimum for mains (pipe sizes 214" & larger) - - _v — Concrete Distance as required to place the fastener above the centerline of the beam or above the bottom • • - • • • • • - • rZ • • • • • • 1 • - _ JOHN- J.! -ABEL -FIRE -'PROTECTION'„ _ _- 4932 PIONEER RD BOTHELL WA 98012 -481-7669 • • 3 • • • • 2,7 217 ELECTRICAL NOTES: 1) INSTALLATION SHALL COMPLY WITH NFPA 70, PARTICULARLY ARTICLE 760, AND SHALL ALSO COMPLY WITH NFPA 72, AND ALL LOCAL ELECTRICAL CODES AND LOCAL JURISDICTION REQUIREMENTS. 2) CONDUIT INDICATED ON PRINTS IS DIAGRAMMATIC AND MAY BE REROUTED PER FIELD REQUIREMENTS. 3) AC POWER SHALL NOT OCCUPY THE SAME CONDUIT AS FIRE PROTECTION CIRCUITS (MOST FIRE DETECTION CKT'S ARE NEC CLASS 3) 4) CONVENTIONAL FIRE DETECTION INITIATING DEVICE CIRCUITS OR NOTIFICATION APPLIANCE CIRCUITS SHALL NOT BE PARALLEL BRANCHED (TEE TAPPED) TO ENSURE SUPERVISION OF WIRING. 5) OBSERVE POLARITY OF ALL FIRE DETECTION WIRING. POLARITY SHALL BE MAINTAINED THROUGHOUT ENTIRE SYSTEM; WIRE SHALL BE MARKED AND IDENTIFIED WHERE SPLICED, AND AT ANY JUNCTION BOXES. 6) ALL FIELD WIRING SHALL BE CHECKED FOR SHORTS, GROUNDS, & PROPER END OF LINE RESISTOR (ELR) VALUES BEFORE SCHEDULING E -SQUARED FOR SYSTEM CHECK OUT. DOCUMENT CIRCUIT READINGS AND PRESENT TO E -SQUARED TECHNICIAN UPON INITIAL ARRIVAL ON SITE. PROVIDE E -SQUARED A MIN. OF 1 WEEK NOTICE PRIOR TO CHECK OUT. 7) FIRE ALARM PANEL, AND ANY OTHER FIRE DETECTION EQUIPMENT REQUIRING 120VAC, SHALL BE SUPPLIED BY A DEDICATED CIRCUIT BREAKER OTHER (NON -FIRE DETECTION) EQUIPMENT SHALL NOT SHARE THE FIRE ALARM CIRCUIT(S). THIS BREAKER SHALL BE LOCKED AND CLEARLY MARKED "FIRE ALARM CIRCUIT CONTROL". 120VAC POWER BY OTHERS. 8) POWER SHALL NOT BE APPLIED TO THE FIRE ALARM PANEL UNLESS A REPRESENTATIVE FROM E -SQUARED IS PRESENT. GENERAL NOTES: 1) NOTIFY E -SQUARED SYSTEMS OF ANY DESIGN QUESTIONS OR CHANGES PRIOR TO INSTALLATION OR FABRICATION. COMPARE DRAWINGS WITH CURRENT CONTRACT DRAWINGS PRIOR TO INSTALLATION. 2) ANY ALTERATIONS OR VARIATIONS FROM DRAWINGS SHOULD BE APPROVED PRIOR TO WORK PROCEEDING AND DOCUMENTED ON THE AS BUILT DRAWINGS. VERIFY DEVICE LOCATIONS PRIOR TO INSTALLATION. 3) REFERENCE FACTORY INSTRUCTION MANUALS DURING INSTALLATION OF FIRE CONTROL EQUIPMENT. 4) USE ONLY U.L. LISTED DEVICES. COODI \ ATI Off\ ITEM S THESE ARE TYPICALLY THE ITEMS THAT GET OVERLOOKED AND MAY LEAD TO DELAYS IN THE COMPLETION OF THE FIRE ALARM SYSTEM AND PROJECT. 1. SITE ELECTRICAL CONTRACTOR SHALL PROVIDE DEDICATED 120VAC POWER CIRCUIT WITH BREAKER LOCK—OUT FOR ALL FIRE ALARM EQUIPMENT. 2. ELECTRICAL FINAL SHALL BE COMPLETED PRIOR TO SCHEDULING E—SQUARED FOR CHECK—OUT, UNLESS REQUIRED OTHERWISE BY AHJ. 3. NOTIFY E—SQUARED A MIN. OF 1 WEEK, PRIOR TO INSTALLATION OF ALL WIRING, DEVICES AND POWER, FOR SCHEDULING OF SYSTEM CHECK—OUT AND PROGRAMMING. E—SQUARED REQUIRES A MIN. OF 2 DAYS FOR CHECK—OUT AND PROGRAMMING PRIOR TO SCHEDULING A FIRE ALARM FINAL. LARGER SYSTEMS WILL REQUIRE MORE TIME. FAILURE TO HAVE WORK COMPLETED WILL REQUIRE RESCHEDULING AND ADDITIONAL COSTS. CONTRACTOR — E—SQUARED SYSTEMS LLC P.O. BOX 731227 PUYALLUP, WA. 98373 253-284-3707 LICENSE: ESQUASL963BR OWNER — BIG LOTS 300 PHILLIPI ROAD COLUMBUS, OHIO 43228 (614) 278-6800 PARCEL # 2623049110 EXISTING FIRE ALARM HORN/STROBES, STROBES AND WIRING MUST BE REMOVED. BY OTHERS. SET STROBE CANDELA OUTPUT AS SHOWN ON PLANS. SET ALL HORN SETTINGS TO MEDIUM TEMPORAL (POSITION 2 ON SWITCH). NOTE: NAC CIRCUIT WIRING HAS BEEN CALCULATED FOR VOLTAGE DROP AND CURRENT LOAD. CHANGING THE WIRING OR NUMBER OF DEVICES ON A CIRCUIT COULD RESULT IN OVERLOAD OR FAILURE OF CIRCUIT. EXISTING 75 75 15 75 95 95 95 r 95 1 B, TYP. • • • / DEDICATED 120VAC PARTIAL FRE ALAR V DISE DIAD 15 15 30 A V SCALE: NTS EOL NAC -1 EOL NAC -4 SILL OF N ATEIALS (SOV) ITEM SYM QTY MODEL NUMBER DESCRIPTION MANUFACTURER MOUNTING B 2C#14, UNSH. HORN/STROBE OR NAC TRIGGER CKT.'S C 2C#16, UNSH. POWER OR AUX. CONNECTION D 4C#16, UNSH. REMOTE TEST STATION E 1 SNAC 1 HPF24S8 8A SNAC PANEL/POWER SUPPLY HONEYWELL IN ENCLOSURE 2 ,c1xx 16 PC2W WHITE, CEILING MOUNT HORN/STROBE, 24VDC SYSTEM SENSOR 4"SQ., 2 -GANG OR 1 -GANG BOX 3 ;p;xx 8 SCW WHITE, CEILING MOUNT STROBE, 24VDC SYSTEM SENSOR 4"SQ., 2 -GANG OR 1 -GANG BOX 4 2 WKAl2-8F 12V-8 A/H BATTERY WERKER FOR SNAC 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 = MOUNT HORN/STROBES AND STROBES WITH BOTTOM OF STROBE AT +80" ABOVE FINISHED FLOOR. 1 FOR ADDITIONAL MOUNTING OPTIONS MOUNT ALL PANELS WITH TOP AT 6'-0" AFF. SEE DATA SHEETS, PROVIDED. SET STROBE CANDELA OUTPUT AS SHOWN ON PLANS. LABEL EOL DEVICES WIRE SCHEDULE CODE DESCRIPTION / FUNCTION A 2C#16 UNSH. UNTWISTED JACKETED PAIR, SLC LOOP, MID -CAP. B 2C#14, UNSH. HORN/STROBE OR NAC TRIGGER CKT.'S C 2C#16, UNSH. POWER OR AUX. CONNECTION D 4C#16, UNSH. REMOTE TEST STATION E 4C#16 UNSH. UNTWISTED 2PR., SYSTEM BUS F 2#14, THHN - FOR USE IN U.G. CONDUIT & WET LOCATIONS WIRING TO MEET NEC 760 STANDARDS Engineered and Drawn By: Nike Hannah NICET Cert : 88649 72" SNAC SEE NOTES ON BOM FOR ADDITIONAL DETAIL NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing. ///y //// //// / //// //// / /// / EQUIPME\T V OJT SCOPE OF WORK CHANGE: INSTALLATION OF NEW SNAC PANEL, HORN/STROBES AND STROBES WITHIN THE BIG LOTS SPACE. EXISTING FIRE ALARM DEVICES, (PULL STATIONS, SMOKE DETECTORS, DUCT DETECTORS AND SPRINKLER MONITORING DEVICES) TO REMAIN. ANY PROGRAMMING CHANGES TO EXISTING FIRE ALARM SYSTEM TO BE MADE BY OTHERS. TI\G DETAIL SC6,LE: NTS FAL TUKWILA FIRE DEPARTMENT Please call 206-575-4407 and give this Fire Remit No. and exact address for shut- wn or restoration approval. Q Y fi c”it Commzits {2ti As N ar'eo in i1 -mss O Per T h _e A c`' Letter These plans have baen revicwe.td by The Tukwila FIre Prevention Bureau for cOr:frrmar`CC: tivrch current City sT ndards. Accepar,c. errcIrs and omissions which do !`Ct aut_ron € vioiT_ Jons of adopted :andards and crU:a:an=_•e:� Tree r soos-s•'S;lity for the quacy of design re cs it -;e resigner. P4 itiorss, deletions or revs: oiate to cniise drawings after trigs date will void r": air ? i=c;` •:i 3 d Wit require a resubrnittai of revise: dra✓+inns for subsequent approval. Final acceptance is sub ect to fed test and Inspection by Toe Tukwila Fire Prevention Bureau. Date: (-/f�- 6r: /V�t J � II "Wtti< ctv.%6 -Lo 1)&00' I.O. 'i a iYd 4v a,'. 17id5. %A e P. ,F D o vi- 0kt-1 tvlov . -6 tx S� �, v k�• . iF1-h S (.t6( l t slwl tr -res, s*k-} put t s+. -i; CO .h'J - Y. 1,, 0140 Shaka °Let_ Asov-e $ICAC. 174a+dvl• • ! hsia(t iprviltty ktolcitt Gttiwy o% dcAti Cam /A• C "114_ N M 00 0) J J m N N O O m N. i) is N N x LJ - N 0 N r) oo N N to N a COMMENTS ISSUED FOR APPROVAL SCOPE OF WORK CHANGE z 0 W 0 N N 0) w Ct z J U L1J C/) >— (1) W (n ><- 0 0 6 06 (1) 0 J C.D 17348 SOUTHCENTER PARKWAY TU K WI LA, WA 98188 JOB #686M FA -01 1 OF 3 SPRINKLER RISER CC (9 Z zo D Iu- (1) I Z b •4- • t 111 FURNITURE ; RACKING I - 30'-0" CONVEYOR / /w ‘75 FURNITURE RACKING 1B 1i FURNITURE II RACKING 11 FURNITURE RACKING ii: FURNITURE il RACKING II FURNITURE RACKING 0 z 0 < . CY STOCKROOM 4,898 SqFt OPEN CEILING r-- ------ w o D Z .1 • I- 2 :1 • I Z 0 LL_-. < 1B EXISTING I EXISTING TS \ / / 18 ‘75 (E) RTU #2 EXISTING 40 x \ / FS EXISTING • • 15 NAC -4 18 • I / • '! I 15 ••••••-•••- /------.,,- • 1BH 2 \ / EOL V,NAC-4 .• • . •. : I••• W .•• i Et 0 H I 0 Z IL-- ------ - z0 FURNITURE 1 FURNITURE 1 0 CY • .. . 1 1-1- • RACKING 11 RACKING .1 I. .1 / • 15 MEN ---- 1B 0 z 2 cr 0 z 0 z 0 \'45 • ;, HATCH 16 / • WOM 15 1B • 11 95 (E) RTU #1 x EXISTING OD '. ' I. FURNITURE RACKING . FURNITURE RACKING 1 FURNITURE ' 1 RACKING i FURNITURE RACKING ... . • . ;1 11 - FURNITURE RACKING .. • 'I . EII EXISTING 1 15 N CY 0 D Z Z 0 IL D ELEC. RM REPLACE ®EXISTING SN AC 3B '-- 28 LAMP yvALL (E) RTU #7 / • 95 FURNITURE DEPARTMENT 1B SqFt (E) RTU #4 x EXIS TING 1B • • • • . I! . . • • , • • • • • • • • • • • . . .• I ' i • . . . . . • i • . . . . . . . • . . i • ; : . . .• .• I .• • • . . . 2 I .• .• \ / : • 1B EOL NAC -3 ••: 95 •1- • • . (E) RTU #6 '1 I SUSPENDED CEILING @ 14' A.F.F. ----- • - • - - • . SALES FLOOR • 20,604 SqFt EXISTIN OD / 84" Lir.....7.7 . .L........ Ia,,,g,...,.6..00----.. 17.-T -1-.1- - ,E).RTU.#3- 1 z 0) w 0 z 0 x NVdS3CIIM NAC - 1 95 . I: ' - 1 • : i I -- (E) RTU #5 I .• 1 . •• ; I ; I 1B • / EXISTING WIRE SCHEDULE CODE DESCRIPTION / FUNCTION A 2C#16 UNSH. UNTWISTED JACKETED PAIR, SLC LOOP, MID -CAP. B 2C#14, UNSH. HORN/STROBE OR NAC TRIGGER CKT.'S C 2C#16, UNSH. POWER OR AUX. CONNECTION D 4C#16, UNSH. REMOTE TEST STATION E 4C#16 UNSH. UNTWISTED 2PR., SYSTEM BUS F 2#14, THHN - FOR USE IN U.G. CONDUIT & WET LOCATIONS WIRING TO MEET NEC 760 STANDARDS SET STROBE CANDELA OUTPUT AS SHOWN ON PLANS. SET! ALL HORN SETTINGS TO MEDIUM TEMPORAL (POSITION 2 ON SWITCH). NOTE: NAC CIRCUIT WIRING HAS BEEN CALCULATED FOR VOLTAGE DROP AND CURRENT LOAD. CHANGING THE WIRING OR NUMBER OF DEVICES ON A CIRCUIT COULD RESULT IN OVERLOAD OR FAILURE OF CIRCUIT. EXISTING FIRE ALARM HORN/STROBES, STROBES AND WIRING MUST BE REMOVED. BY OTHERS. • 1 . . • • . • • • • • • , • • • • • • , . • • • • • . . , . I _,..." . • . • 18 -- _ _ - I _ _ .• • .• _ _ -------- i • • I- • • • . • 1 1 • . t • • • . . • • • • 1 • • • • I • • • • • NORTH FRE ALAIV FLOC) LAN SCALE: 1/8"=1' EXISTING El EOL30 1' NAC -1 MANAGER OFFICE - w cr) 15 frj zD 0 .0 CASH CASH ,• V) h co (3.) - < CO F- • < < >- >- v.) O CL - UJ 0 (/) PO BOX 731227 PH: 253.284.3707 ISSUE COMMENTS ISSUED FOR APPROVAL SCOPE OF WORK CHANGE z LLI a) c.1 cn cn uJ LiJ LL_ LJ LL_ FLOOR PLAN LJ Li TUKWILA, WA 98188 JOB #686M FA 02 2 OF 3 illi.1.111111.61.1/161.11i111.11411111i11111101011111Milk11 ,1 al 41 Vali NAC -4 NAC -3 NAC -2 NAC -1 I --I DEDICATED 120VAC POWER BY SITE ELECT. _ EARTH HOT NEUTRAL 120VAC POWER • • • 0 • • 0 XFMR 2 XFMR 1 TB1 Fl, 15A 32V BAIT. BATTERY (-) r_ BATTERY (+) 0 U J L L U U (-) (+) (+) (-) (+) (-) (+) NAC -4 NAC -3 NAC -2 NAC -1 FCI HPF24S8 POWER SUPPLY AC POWER GROUND FAULT BATTERY TROUBLE NAC TROUBLE Ff-- CHARGER TROUBLE 0000 LED'S (+) 8588H TB2 NO NC C TB5 TROUBLE RELAY FORM -C FAIL SAFE NONSUPERVISED KI3830188 ZNAC 4 CONNECTOR (-) AUX COMMON (+) AUX 24VDC (-) CONTROL INPUT 2 (+) CONTROL INPUT 2 (-) OUT COMMON OUT/TROUBLE CONTACT (-) CONTROL INPUT 1 (+) CONTROL INPUT 1 (-) SYNC INPUT (+) SYNC INPUT SW1 L 0 0 JP1 JP2 I I JP3 471(,1/2W FROM EST ( C1 0 TB4 SWITCH 2 AND 4 UP ALL OTHERS DOWN (+) 12V-8AH BATTERY () (+) 12V-8AH BATTERY () 1B TYPICAL FROM EXISTING EST CC1 MODULE SNAC PANEL WIRING DETAIL SCALE: NTS INSTALL NO CONDUITS IN BOTTOM OF CABINET OR BOTTOM SIDES, TYP. cc 0 I MOUNTING PLATE JI 4" x 2-1/8" J—BOX, TYP. TYPICAL HORN/STRO3E & STROBE MOUNTI \G DETAIL SCALE: NTS OUT -1 OUT -2 4.7K OHM 1/2 WATT 4.7K OHM 1/2 WATT WIRE SCHEDULE CODE DESCRIPTION / FUNCTION A 2C#16 UNSH. UNTWISTED JACKETED PAIR, SLC LOOP, MID—CAP. B 2C#14, UNSH. HORN/STROBE OR NAC TRIGGER CKT.'S C 2C#16, UNSH. POWER OR AUX. CONNECTION D 4C#16, UNSH. REMOTE TEST STATION E 4C#16 UNSH. UNTWISTED 2PR., SYSTEM BUS F 2#14, THHN — FOR USE IN U.G. CONDUIT & WET LOCATIONS WIRING TO MEET NEC 760 STANDARDS SET STROBE CANDELA OUTPUT AS SHOWN ON PLANS. SET ALL HORN SETTINGS TO MEDIUM TEMPORAL (POSITION 2 ON SWITCH). NOTE: NAC CIRCUIT WIRING HAS BEEN CALCULATED FOR VOLTAGE DROP AND CURRENT LOAD. CHANGING THE WIRING OR NUMBER OF DEVICES ON A CIRCUIT COULD RESULT IN OVERLOAD OR FAILURE OF CIRCUIT. EXISTING FIRE ALARM HORN/STROBES, STROBES AND WIRING MUST BE REMOVED. BY OTHERS. z 1B, TYP. OUT -3 z 1B, TYP. OUT -4 TYPICAL NAC WIRING DETAIL SCALE: NTS 4.7K OHM 1/2 WATT 4.7K OHM 1/2 WATT ISSUE COMMENTS ISSUED FOR APPROVAL SCOPE OF WORK CHANGE LJ CNI 0 SCALE: NTS LLJ LJ- LLJ LL CONTROL PANEL DETAILS LLJ LL CZ (/) 0 0 17348 SOUTHCENTER PARKWAY TUKWILA, WA 98188 JOB #686M FA -03 3 OF 3 2 A HALL 11 COAT B- •4 ll� 75 30" B+,. ----1 15I�' F_�_--„, HALL L� y \ AMA. MLRIr A 75 ) 75 LAYAWAY eTaRme GL r- 15 15 754. A 7 }JCeeeaie ROOM 75 T7AR9+uy. EAS.k t ooq 7 �75 110 EOL .vn41 IN RCEPT EXISTING CIR IT ji + B 75 `A, KeTpl.t {r 6 INTERCEPT EXISTING ill CIRCUIT �-B 30 .11u 4K —B 1D 30 8 PTaa. IeF1 15 EGL . , . ® ® a51-8—IJ—LJ---LJ—S LJ , 15 15 15 30 75 75 75 75 110 110 110 EOL ® ® 8 tJ S Lf—LJ U U 8 75 75 75 75 75 75 75 30 30 15 B 8 INTERCEPT EXISTING POWER SUPPLY SIGNAL- CIRCUIT �i TO 120VAC, TCHED, DEDICATED CIRCUIT FIRE ALARM RISER DIAGRAM NO SCALE EQUIPMENT LEGEND OTT. MEMEL ® 1 SK5495 1 D412 ( Q •r . fllP' g vot,taw 110 04 7504 3004 1504 75= 15 DESCRIPTION BACKBOX SIGNAL EXPANDER POWER SUPPLY PROVIDED SYNC MODULE 4-1/16” SQ., DEEP PULL STATION - SINGLE GANG 1 D572S HORN STROBE - 110 cd 4" SQUARE DEEP 11 D574S HORN STROBE - 75 cd 4" SQUARE DEEP 2 05735 HORN STROBE - 30 cd 4- SQUARE DEEP 1 0570S HORN STROBE - 15 cd 4" SQUARE DEEP 2 D546S STROBE - 75 cd 4" SQUARE DEEP 3 D544S STROBE - 15 cd 4" SQUARE DEEP SYSTEM INSTALLATION NOTES: 1) All work is to conform to National Electric Code standards. 2) Wiring method is to be open cabling except where it is exposed and \/rn below seven feet - then It is to be In conduit 3) All )unction boxes, covers, and back boxes are to be painted red. �I 4) Pull stations are to be mounted at 48" to 54" above the floor. 5) All indoor home, strobes, horn strobes, and mini horn strobes are to be mounted 80" above the floor or 6" below the ceiling, whichever Is lower. (5/6) Smoke detectors shot be Installed in accordance with the following: A) 36" inches away form any oir handling system diffuser B) Not in close proximity to any fluorescent Tight fixtures 7) Exterior bell / strobe shall be mounted on the top 2/3 of the outside wall of the building, as high as possible for maximum visibility fromthe fire deportment access roadway. 8) All fee alarm wiring penetrating any fire rated barrier shall be sealed with T material which will prevent passage of flame and hot gases. 9) A9 new devices are to intercept existing circuits.. CPWIRE LEGEND A 18 AWG, 2 CONDUCTOR 'FPLP' JACKETED CABLECP B 14 AWG, 2 CONDUCTOR FPLP JACKETED CABLE l / '` '''' FLAG NOTES I l t rc \ ® CEILING MOUNT OCT 1 8 2001 e°C /fir FIRE ALARM PLAN SCALE: 3/32 - PRO ALARMS PLUS, INC. 9004 NE 132 PLACE KIRKLAND, WA 98034 (425) 825-0778 FAX (425) 823.3798 SS�SSS DATE: 10-02-01 DRAWN: CEA CHECKED: JD APPROVED BY: PROJECT NAME: MARSHALL'S SOUTHCENTER PARKWAY Tukwila, WA SCALE: 3/32=1'-0" NO. DATE REVISION BY SHEET TIRE: FIRE ALARM PLAN JOB NUMBER: FA -1 1 ea,J Nrr".4 7 2_ —/ f- 4 6 di 'HC J3;<- 111172-1,/de: .1"-'5-1 - E7 -4 -of rb rw 0 Ser.Iglay11.11.1.64,14,11.xart,....114.4.0. / /s Noi,j fr Tr 1rC Lefzer These plans have 1,6 01 h 't".‘1,41e1 Prevention Bu,1 rcurrent c:;ty standards. Accopt....;;-,;-;... omissions which ‘horis of rittppte;;:l standards and orciinwIcee.. The responsity tc.)c the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings tor subsequent approval, Final acceptance is subject to field test and inspection The Tukwila Fire Prevention Bureau. By: f Date: TUKWILA FIRE DEPARTMEN1 Please call: 575-440Z --- and give this job ---7C)"E and exact address for shut' down Or restoration adorovaL NOTICE A completed, signed, itikwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of A ccepta ce Testinv any Fire Alarm and Detecfion Systeho. Failure of test will result in $44 Inspection Fee and termination of the testing. &JSr !J IU.S€!. NNS Nrc' . u.. -r ia,t /.,se,./G,. L`4ti` �1•c 1 i i I u t , ! I i ,_, _ — b •.1- !---t I i_... i__. i i.. !I -{ +-- y -. i i ... '....... r -r 1 , _ _ a.t , 1 1 I I r JLLJ 0rcKi c'� 0 /(5) 0 ' , 1 • 12. (p1i ! ', F. I /It I 1 -la i 1I • p r • ® ` ` i _. IJ _l—�•.._ 'tv T't _�t - ._t .! 1--- 1 ,=, .�! I ( tb -+•_ i I , 1 1 l•I �� `sir.JJ.T.l ito•= 1•i /) d I ; ;j/' n_..._ L� _ a' 14+ - T / —=—I �r �lliL 1 ! 1 LI 16.157".- lli be i ' Ac i 1 I nr. , EK•; cr. t I 1 -9 -ml 1 9-I[� I 1 i I j t i .— - _ - �---r - - j �� �._ _ � -4 ! i jlj ! til I I t 1 r f f ! ! f • 2 ii } I I • etlr.l �0 (Q ' 1 i , i . iL , (p ; I 1 i 1 0 (V)^ /2 0 f p �' (pl 1 %a I ; p 4 r fid z z Lu z r - a U /h;7” FIG. 58 TYPICAL APPLICATIONS FOR FIG. 58 THREADED SIDE BEAM BRACKET THREADED SIDE BEAM BRACKET Sire Runge • 3/8' kod • pipe sizes 1/2" thru 4" Material- Carbo, S;ra Function`- Practical and economical bracket used to support piping Irons wood, concrete or steel beams Features • Unique det:gn allows rod to be easily ...Shielded into bracket Onset design pemltu unlimited rod adjust- ment Center mounting hole will accept 3/8- & 1/2" Wiener bobs Per tlF.P.A. °l3: 1/2" thru 2" pipe requires 3/8' fastener. 2 1/2•• Ihru 4' pipe requires 1/2•' fastener' Approvals • Undenvmscr Laboratories Llsled, Canadian Underwntro Laboratories listed and Factory Mutual Englneedng Approved through 4 pipe 'Note. U L and F M. tared the Fig 58 utilizing 2 • s 16.2" drive sctewslF:g. •125). This fastening method was found to to adequate fur ust on 2" pipe and smaller In w'o;.: construction Finish • Plain and Elet'o-Calvanlzed Order By • Figure numaer and finish ►ATV(T PENDING r-1 tr J iJ 1104—7/r►b1t-_. sae WE/GM roe 01/E A a G DI OI a ma 100 1/2 THRU 4 2.3i:- 3/8" 1.1/8" 33/64•' 17/64" 7/16" I.7/8" 1-1/2" 14 Shown Here Hanging up to. 4'• Pipe with Lag Bolt .1 t Shown Here Hanging up to 2" Pipe with Drive Screws 100° S>l Woe. ,Zr=Are✓E tr ?t1.1La AIuh PTP E Tb -'c- S41,4. LAC-••!lD�.I I YPICA /Plnl� G/x/FI L/�AT !DICT ck s 348 s��, �PY • ,. j. --1.1 - a���1C� ETZ L /1 rJ SGAL.E . _ n/o•r=s : Drs, c. j PE,L h%F PA /3 LI /L6, • 4 -AA 2.. 0 /4 ©Obi Ta rye L -2ef[o AAA 2,n L5 Lit L G,z F,t.n ApP2o fci PIP, —e a!= . pp .tz r A /i s S s..low s.. .' ry rt -i et. -s L. CTL %ETA ✓ L fCwJan..j-r .4.SP2/NKIr(-7LS F,vcJ r. /1' du72eT aq5 S0.0of ,e -J her-ar, .✓ti O17.l6ktot, rSC, Etct3T. Lail, UP.1,G,-/•r Tu /ZAMAA.Ara Z aL.546 1•.c6v_ F, G,••ra - /2 . ISS' , i Abh /2i1-SC0 Moll. F/ Lan. LIPA • ••, • 1()) I-1 —&-c q 1C ,k kArmAb_< :3 Qek \`'A` \� 1 {)A `. V CCEPTED ❑ Without Comments As Noted In Red ❑ • Per The Attached Letter II These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date:tt)\(15 (0) By' \,)A 510 TUKWILA FIRE DEPARTMENT Please call: 575.4407 and give this job Noe 0\ .S Z'\ and exact address for shut= clown or restoration approval /�'F••� A 12-E /k L1 F Z. AJST(1(1 GT -1 D 'NJ AAA WALLS / -Est IST. Te-.vRw,.?� // I I�rra - kaitaeJ AAt&j ILLE1L kit✓?,_ CROWN FIRE PROTECTION INCORPORATED P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0173 PH. (206) 481-7669 / 73 /8 So e1TiJ Gca _, rE 2 P/eluY. T U Ie w / La , PL/* . , SEP 1 4 zuul */-/61511/67-' DATE: 9- v4/ . o I DRAWN: AA.e. r/,1 SCALE: /C/are A /or/ AREA OF i-r..3P.14, / <7,/vVe - '1 14'1 LEI,/ OFFICES = 11- GPRI1,111,LERS: fIELIREaLE L4EL 'La" PEUD.E.LI 14;b5* V2." 0 10 D. r -c ro - IDYL 1;? • • Hanger Rods / Fasteners: 0 All Thread Rods • Finishes: 0 Standard Components Clip Hangers Hanger Rings: UL Listed & FM Approved Comply with NFPA 13 O Machine Thread Rods O All Galvanized CQmponents 1' = 25.4 mm Components 1. Clip (Ceiling Flange) 2. Hex Nut 3. Wood Screw 4. Hanger Rod 5. Adjustable Hanger Ring Application / Description No. 5 Hangers are designed to support small piping from smooth level wood planking that has a thickness sufficient to receive the required fasteners. The hanger is secured to the planking by means of a clip (ceiling flange or hanger flange) that is provided with a standard thread for the rod and holes for 2 wood screws. To prevent possible loosening of the rod due to vibration, the hanger is further secured by a hex nut tightened against the clip. There are 6 components in a basic No. 5 Hanger: The clip, 2 wood screws, a hanger rod and locking hex nut, and an adjustable hanger ring. The rod may be either all thread rod (ATR) or machine thread rod (MTR). All thread rod is considered to be standard, however. As a rule, machine thread rod is provided only when it is a specific require - No. 5 Hangers may also be used with other types of construction of adequate strength when provided with 'tillable fasteners — subject to the approval of the authority having jurisdiction (AH.1). Deviations from standard fas- teners are to be clearly indicated on the plan by detail or in a hanger note (see Hanger Codes /Plan Designations). NFPA Requirements / Limitations NFPA 13 permits the use of 2 screw ceiling flanges only for pipe sizes up to 2" and it calls for the use of screws having dimensions not less than those of No. 18 x 1½' wood screws. Drive screws and nails a' not ar-rentphto 142 - 4d er *-* de' C9 (4f + / 11,2b,. - 1 c.- <-1 • EX I STg FIT FLR ii --1 C_RLE /1E7 C1 I'tL 0 1 0 - -0 ;/..4 . - CYL - t• 1 4, 0 i 'a -o 1 -.2e Rod Hangers • Hanger Rings / Anchors: UL Listed & FM Approved • Hanger Rods / Fasteners: Comply with NFPA 13 • Machine Thread Rods Only • Finishes: 0 Standard Components 0 All Galvanized Components 0 No. 131 for Wood Components 1. Eye Rod - 2. Flat Washer 3. Hex Head Cap Screw 4. Adjustable Hanger Ring 5. Drop-in Anchor 6. Hex Head Lag Screw 7. Expansion Case 8. Lock Washer 9. Hex Nut 0 No. '132 for Brick 0 No. 133 for Concrete 0 No. 134 for Steel * NFPA 13 sets minimum distances for placement of fasteners above the bottom of beams or joists. Wood: 21/2" (64 mm) minimum for branch lines (pipe sizes 2" & smaller) 3" (76 mm) minimum for mains (pipe sizes 21/2" & larger) Concrete: Distance as required to place the fastener above the centerline of the beam or above the bottom reinforcement steel. HRLIL3ER LD SCALE WITI-131JT COMMENTS:: D IN RED .'LR HE ATTAC,-IED LETTER Tly.? affixeJ hereto have been re4i77,-, .LIcc.;ted by the City of Tuk-;11.D Allitions, deletions s- ,,,.1ns after this -La- :i and will of revised drawings. Fii1 tp field- ,reentaive of this DY: CITY CF TUKWILA 575-440/ 1 V TE ._Pt_RL.1 1.10 C=CALE TUKWILA FIRE vEPArifsti Please call: 575-4407 and give this job S 5/7 and exact address for shut. down or restoration approvd. ,e4t;ri ierzA At5 JOHN J. ABEL FIRE PROTECTION 4932 PIONEER RD BOTHELL WA 98012 481-7669 DPNLJL.3 f=',DF\ TELIRL1 T T 4•D=ILJ1' 1-1C ELI T f---nt-A3A.1-6,, TUKV-$1 LR , Fi DATE: 0- - DRAWN: SHEET 1 OF 1. SR 888 QRS 0-'4( rats 1'it+�"� V'`1 a9?h. 1 21.4' Fula? . U G i-1TW t -t 1 AGoue-.7TICA L P5 1--10E9 y -r 1--1 - Sel 51-11 c11o.-' f egonzeo Li--U4-111-L8TeD GOV-44 JC -E J¢ LUJ4 y- ...rte... O 12 t-tr TT2AG K r IZ LFr TP-aG#- L ARP 1 t �a 01-011 19,'-0" 771,0" 11�'-Op 11;'-os 4' 11 t -F. �F- 1 t1 I -F. TV -A( -1C - 2T 1(27E)4Ia0 FLLk. L -1 6,T11-461 O C- 12 t -r. . TuAGK 1_ Llu4,1 I 4.1 I -O' t4' -o" 7 -L e', PENDa1T F1 -.-UC. Thee 1--46tuT s J' Df 1 D �$ i.r. �?.a�,1✓ e> 4' R--tk • LI6NT G C64 WW1 I 1 AGD U r�T'C4.1- GiY�1��-'1. E 4 LF TEAtx T O REFLECTED CEILING PLAN At. : fig, - 1 '- ol3 — -� --Q O .-- 1. 1-Ifi46CN 1 1-46 1 H11 RER- x'11 TYPe ll _P • wirri 1. 1 E"-- 12 t -r. 1144«C 1 0 11 14. - DRot 5 Recd -TED t=iowr El: siriijL 'ST v1/4 ix- Moog `- LD -Z %t Xf - I b 5 ` PPC � p JOHN J. ABEL FIRE PROTECTION 4932 PIONEER RD BOTHELL WA 98012 481-7669 DRUL3 Eti-1�(�IUt�I TELIRtJT IK PPC3./Ei-4F_LiT SbUTHCELITEP. PRn.I<.wr-4r TL_11LVKILR DATE:1- 042_ DRAWN: _1'S SHEET Z OF 2. SR 888 I • Df 1 D �$ i.r. �?.a�,1✓ e> 4' R--tk • LI6NT G C64 WW1 I 1 AGD U r�T'C4.1- GiY�1��-'1. E 4 LF TEAtx T O REFLECTED CEILING PLAN At. : fig, - 1 '- ol3 — -� --Q O .-- 1. 1-Ifi46CN 1 1-46 1 H11 RER- x'11 TYPe ll _P • wirri 1. 1 E"-- 12 t -r. 1144«C 1 0 11 14. - DRot 5 Recd -TED t=iowr El: siriijL 'ST v1/4 ix- Moog `- LD -Z %t Xf - I b 5 ` PPC � p JOHN J. ABEL FIRE PROTECTION 4932 PIONEER RD BOTHELL WA 98012 481-7669 DRUL3 Eti-1�(�IUt�I TELIRtJT IK PPC3./Ei-4F_LiT SbUTHCELITEP. PRn.I<.wr-4r TL_11LVKILR DATE:1- 042_ DRAWN: _1'S SHEET Z OF 2. SR 888 X D- 0" fi — v 0 i L,tj�U��S 10,5 � •J }�' i� • 4 .• Fc , A r sQ t -1w x Oita b H. z.►�� t-1 . WO n►is MI u► unsa► i st it ivado� o pa,wEp to Ault X34 ilt lets Pte► el pedsai 41i"pas►dlnxa uaeq se4 n AeM Aug DI au►seaq se panto � 3 e �2b eel u0d n suo►l aq s panto )1e3�014ou en atu sale) a3ue+nsu► airs uod ue sPU0 snout* 403 I 40 04 AI�nidte pietas s�3ue�dea3e P aw tuol IN •pugda33e Tug tot E�'I�;aMISlI@��I � � ►1d § •uoe2K1-0004$ Mtledns3o p► kev n io 11 @ ial e►d 01 sailed, vaunt, f ,all paid kid 10;ee p4xl14 041 us pa,u W� ld t M II�IUu !0 iltle tiIflON 1111isill! § p�Nuuts s, uo►le3�pst5Gt ( � WV HSGGYiM 3111435 A 0896 UVU i AiOil 19IIINSYN a31d330V ACCEPTED WITHOUT COMMENTS. AS NOTED IN RED 0 PER THE ATTACHED LETTER The drawings affixed hereto have been reviewed and accepted by the City of Tukwila Fire Dept. Additions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings. Final acceptance is subject to field - inspection by a re,resentative of this del ' rt-.-ent DATE e" 52�__._ _ CITY OF TUKWILA 5-15.440/ PIPTI r AUG 151991 LiL--.L1 1) A T D FILE r t i 4 eel > • n 4, 42`Y; s t 414 I M• ,4z14+!` 15,4.6. I V i 4 TUKWILA FIRE DEPARTMENT Please call: 575-4407 and give this job No. 67Y— 5// and exact address for shut- down or restoration approval. 4 JOHN J. ABEL FIRE PROTECTION 4932 PIONEER RD BOTHELL WA 98012 481-7669 173ya 5»rrtj, DATE. ' DRAWN 17;',:f SHEET j OF / .� s eA.L/ FIRE '•• 1 CO. 22131 WEST VALLEY HIGHWAY P.O. BOX 1266 • KENT, WA. 98032 LIC. NO. SU-PE-RF-P245BN (206) 872-7100 i .ACCEPTED WITHOUT COMMENTS. AS NOTED IN RED [Q PER THE ATTACr:ED LETTER The drawings affixed hereto have been reviewed and accepted by the City Tukwila Fire Dept, Additions, or revisions to these drwins aft:y this date will void this ecceptan:a an(I require a resubrnittal of rev.is• ; i gs. Final acceptance is subject to ;i3)I- inspection by a representative of tris department DATEF� 8Y. CITY OF TUKWILA 575-4407 /734k 5:atfact-zr 9 DESIGN • INSTALLATION 10<-0 14JK 1A 1=1 R E DEPARTME T Please call: 5/b -44U/ and give tyi bi No. 0 U and exact address for shut- down or restoration approval. 7- :- ATIC FIRE SPRI.rF' SEF !CE E -44.,o 0 P-144 I+s /7318 5---044.1XCe„1/2r. a.4 &A 4i . `-- i*proXi`� +c AUTOMATIC FIRE SPRINKLERS INSTALLATION a EYEROO & RING - C CS &RING 4 t%2 II<xi ST C CLAMP ROD & RING CLG FLG M T ROD & RING TWO WAY EO BRACE FOUR WAY E0 BRACE INCHES -STRUCTURE TO & PIPE TEMP RATING 0165 -. 286 • G212 - PIPE SIZING & SPACING CONFORM TO NFPA PAMPMLET NO t a cTAKZIMc WA a Ms, i HAZARD OCCUPANCY " _ •F i ALE MATERIALS & EOUIPMENT TO 8E NEW do 41 UNDERWRITERS APPROVE() I J OWNER TO PROVIDE ADEQUATE- MEAT TQ KEEP P(PEFROMFREE2IN© p = z 5 -z w 0 Q m 2 ACCEPTED WITHOUT COMMENTS AS NOTED IN RED- [] PER THE ATTACHED LETTER The drawings affixed hereto have been reviewed and accepted by the City of Tukwila Fire Dept Additions, deletions or redisions to these drawings after this date will void this acce-)tante and will require a resubmittal of revised drawings Final accepta %E s rem ntative of this ect to field - ins Jec�ion by `�d de) rt Ent DATE _. EY 1 i e G. TUKWILA 5,b 44J1 TUKWILA FIRE DEPART,J1:,NIT Please call 575-4407 and give this job I _ r _ %2—Q c�E.r.4 4— - _ -^- 4 - - , - - 4 t and exact address for shu down or restoration approval 7- 3 t ' z f=W 1 COOP 4 44 9 $'S 1. %v1GDt„ 't�t.11iE.1 - Yg s i -tom - 41 _ 44 s 44 -- R •Ta t - r .. _._-4 - ta 44 3 • SYSTEM TYPE HVDRAILIC DESIGN # DENSITY GPM A. AREA SO FT CLG r-t.G M T ROD & RING -44 fG A TWOS WAV EO BRACE FOUR WAY E0 BRACE 0165 $212 TEMP RATING A e 286 — PIPE SIZING & SPACING CONFORM TO NFPA PAMPHLET NO 11 STANDARMPQR,St 0D �.:,, HAZARD OCCUPANCY AU. MATERIALS i EOUIPMENT TO BE NEW i UNDERWRITERS APPROVED s LOWNER TO PROVIDE ADEQUATE MEAT TO KEEP a PIPE FROM FREEZING - a ti tb," t - ACCEPTED sv WITHOUT COMMENTS �4ASNOTED INRED ' THE ATTACHED LETTER The drawings affixed hereto have been reviewed and accepted by the City of - Tukwila Fire Dept Additions deletions or revisions to these drawings aft:,r tills date will void this acceptance Gnd will require a resubmittal of revised drawings Final acceptance is subject to field inspection by a representative of this - department r t1 SPRINKLERS ZON410.1ZWT 140'1' 41'14 '} - y. sot , +w4©I� 0000 �fr 3 fot t ea _ of tom eDe<NC 4.h4?3-. 0 RI CIO ` § i - f a v- z v. t r_ _ 7