Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PP - 4062 S 128TH ST - RESIDENTIAL - PERMITS AND PLANS
4062 S 128TH ST ASSOCIATED PERMITS 17-5-134 D17-0084 ( INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit Dr7-- oo g4 �-- S- 134 - PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: (Z',r � � U Type of Inspection: 6 -01/& -72 - Address: {.._ Suite #: 4 62 S. (2-6' ontact Person: 51 Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: D' I 1a V&- 15 D e l 3- G"-( S 3 d 5 -c.- . oa s HltiOg-o Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: f -y4 Date: `7-Z7_ //7-4 Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 HARDENED HEX HEAD SELF THREADING SCREW IS FURNISHED WITH THE HANGER AND IS THE MINIMUM FASTENER SIZE ACCEPTABLE CPVC DOUBLE FASTENER STRAP TYPE HANGER TOLCO FIG. #24 HANGER TYPE CP NTS HARDENED HEX HEAD SELF THREADING SCREW IS FURNISHED WITH THE HANGER AND IS THE MINIMUM FASTENER SIZE ACCEPTABLE "OFFSET" HANGER & RESTRAINER FOR CPVC AND IPS PIPE TOLCO FIG. #28M HANGER TYPE CP NTS HARDENED HEX HEAD SELF THREADING SCREW IS FURNISHED WITH THE HANGER AND IS THE MINIMUM FASTENER SIZE ACCEPTABLE "DOUBLE OFFSET' HANGER & RESTRAINER TOLCO FIG. #29 HANGER TYPE CP X11 BEDROOM #4 I IIi*• 1.1 li.. GARAGE LINEN 11 NTS FURN ;,, OAS FIREPLACE PATIO 10'90' (lit DINING GARAGE DN KITCHEN OPEN TO ABOVE. • PANTRY i PDR. 1 OFFICE / GUEST COVERED PORCH MAIN FLOOR - SPRINKLER PIPING PLAN SCALE: 1/8" = 1'-0" ATTIC INSULATION (BY OTHERS). USE BATT TYPE INSULATION FOR TENTING CPVC FIRE SPRINKLER PIPE BOTTOM CHORD OF TRUSS i TENT FIRE SPRINKER PIPE. BEFORE INSULATING ATTIC (BY OTHERS). USE BATT TYPE INSULATION FOR TENTING. GWB CEILING WET PIPE FREEZE PROTECTION DETAIL NTS 1% 0-4 SCH 40 TxrrGQQ> J (2) FSI START POINT 1'/, S X G ADAPTER 1'/4 FLEX COUP 1Y40-4SSGXT 1% FLEX COUP 1%0-4SSGXT RISER LEGEND 1 - 11/2' WATER SUPPLY LINE 2 - 11/;' AMES 2000B BACKFLOW 3 - WATER FLOW ALARM SWITCH WIRED TO ALARM BELL 4 - WATER PRESSURE GAUGE 5 - 1" VALVE FOR DRAIN 6 - 1" DRAIN LINE PIPED TO EXTERIOR OF BUILDING 7 - 6" ALARM BELL INSTALLED ON EXTERIOR OF BUILDING RISER NOTES 1 - ALL CONTROL VALVE HANDLES TO BE REMOVED AND PLACED IN HEAD BOX AT TIME OF FINAL 2 - WIRING OF FLOW SWITCH AND BELL TO BE BY OTHERS 3 - 1W SUPPLY LINE TO BE PROVIDED BY OTHERS HYDRAULIC DESIGN INFO !A THYDRAYULICALLY DESIGNED ❑ HYORAULiCALLY DESIGNED - FLOW TEST - STATIC: - 106 PSI RESIDUAL: - 20 PSI GPM FLOWING: - 1350 GPM DATE & TIME: - 7/6/17 - SYSTEM DESIGN - REMOTE AREA: AREA 1 DENSITY: .05 GPM / SQ FT MAX AREA/ HEAD: 16' x 16' K -FACTOR: 4.9K liOPEN TO BELOW esidential*0.05gpmlft2 for 187.25ft2 REMOTE AREA #1 THIS AREA HAS BEEN HYDRAULICALLY CALCULATED TO DELIVER A RESIDENTIAL COVERAGE (NFPA 13D) OF: 13 GPM @ 7 PSI USING 16' x 16' HEAD SPACING SYSTEM DEMAND: 26.4 GPM @ 56.8 PSI UPPER FLOOR - SPRINKLER PIPING PLAN SCALE: 1/8" = 1'-0" SCOPE OF WORK: INSTALL NEW NFPA 13D FIRE SPRINKLER SYSTEM THROUGHOUT NEW RESIDENCE. GENERAL NOTES: 1. IT IS THE RESPONSIBILITY OF THE OWNER TO MAINTAIN THE INTEGRITY OF THE SPRINKLER S 2. ALL MATERIAL AND EQUIPMENT TO BE NEW AND UL AND/OR FM APPROVED. 3. ALL SYSTEM PIPING SHALL BE TESTED AT STATIC PRESSURE PER NFPA 13D. 4. PIPE HANGER AND METHOD OF HANGING TO BE IN ACCORDANCE WITH NFPA #13D (2013). 5. OWNER TO PROVIDE ADEQUATE HEAT TO PREVENT WATER IN PIPES FROM FREEZING IN AREAS PROTECTED BY A WET PIPE SPRINKLER SYSTEM. 6. STRUCTURAL ADEQUACY OF THE BUILDING TO SUPPORT THE SPRINKLER PIPING IS THE RESPONSIBILITY OF THE OWNER AND/OR HIS STRUCTURAL REPRESENTATIVE. 7. ALL FIRE ALARMS, WIRING AND MONITORING ARE TO BE INSTALLED BY OTHERS. DESIGN NOTES: 1. RISER ASSEMBLY / PUMP AND TANK TO BE LOCATED IN THE GARAGE (FSI START POINT). 2. SYSTEM TO BE DESIGNED IN ACCORDANCE WITH NFPA#13D SINGLE FAMILY RESIDENCE. 3. PLAN SUBMITTAL TO AND APPROVAL BY CITY OF TUKWILA. 4. MATERIALS PER NFPA #13D STANDARDS AS SELECTED BY FSI. 5. TESTING PER NFPA #13D AND CITY OF TUKWILA. 6. TYPICAL HANGERS TO BE TOLCO FIG. 24, 28M & 29 UNLESS NOTED OTHERWISE FIELD NOTES: 1. ALL NEW PIPE IS TO BE CPVC. 2. ALL NEW FITTINGS ARE TO BE CPVC. 3. DESIGN CRITERIA TO BE BASED ON NFPA 13D: A. SPRINKLER SPACING NOT TO EXCEED (16' x 16') OR (9') OFF OF WALLS MAXIMUM. B. MINIMUM PRESSURE AND FLOW FOR SPRINKLERS SPACED 16' x 16' = 13 GPM 7 PSI. 6" ALARM BELL INSTALLED ON EXTERIOR OF BUILDING (WIRING BY OTHERS) METER SOURCE Without Comments As Noted in Red O Per The Attached Letter These plans have been reviewed by The Tukwila Fire !?rev::ntion Bureau for conformance with current City standards. Acceptance is subject to errors and • omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer, Additions, deletion c revisions to these drawings after this date will void tills acceptance and will require a resubmittal of r'e,./is drawings for subsequent approval. Final acceptance is suoJect to field test and Inspection by The Tukwila File Prevention Bureau. 5//I C NEW HOUSE FSI START I DG 1 %z' POLY WtIT (NSTALLED BY OTH N= SITE.. PLAN SCALE: NTS z L W's1 dL-c' retv;14. ve ,iv4r TUKWILA FIRE DEPARTMENT Please call 206-5754407 and give thus Fire Permit No. .17-S-13 and exact address for shut- down or re:•baration clppr©val., R SUPPLY LINE RS) S 128TH ST °VICINITY MAP SCALE: NTS PAID JUL -7 2017 TUKWILA FIRE WA CL# FIRESI"988RI 1524 45th Street East, Suite 102 Sumner, WA 98390 (253) 826-0099 www.firesprinklersinc.com DRAWN BY: J HENSLEY REVIEWED BY: MPM DATE: 7/5/17 SCALE: AS NOTED AHJ: CITY OF TUKWILA REVISIONS: REV# DATE BY DESCRIPTION ST LMP: WASHINGTON 4,1 ATE CIEWIWICIATE OP COMPETunc. v PEAR PROTECTION SPRINKLER SYS', Michael Paul Moffett 4513-0612-C Level 3 Fire Sprinklers incorporator. FIRESI*988RJ 7.1,1.i7 III naturrn • f; MS ;i{ W-17:1 6 1$J3'1•1:• Mall ON Mel o SPRINKLER LEGEND a N N 1- N 0 w S 0 co z tL Le m m 0 0 H a. 1 - UD LO 0 N 10 1r 1 r 0) u_ rn v rn w 0 a 0 z O 0 0 a 0 z 0 0 DRY PNDNT D rn w re 0 z rn rn Y rn Y In M N SYM I MANUFACTURER z z 0 0 O TOTAL THIS SHEET = COFr) ce 1,== ing= tam r�E"""/ 000 vTJ W i 0) 00 C\I err (/) J_ o 2 CONTRACT WITH: AMERICAN PRESTIGE HOMES SAN STEVENS (206) 853-4525 HANGER LEGEND: CP CPVC HANGER f. DRAWING SYMBOLS: 11111+111 - FLEXIBLE GROOVED COUPLING - RIGID GROOVED A.1 - WELDED PIPE TAG COUPLING #1 NUMBER e PIPE HANGER (SEE CHART) 9-0 PIPE SIZE & LENGTH CUT J SEISMIC BRACE W 10'-10' FF - ELEVATION DATUM ( ) - HYDRAULIC NODE * 0'-10" TS 1 - CENTERLINE OF PIPE TO DECK JOB NUMBER: 7439 SHEET NUMBER: FP1of1