Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PP - 12674 INTERURBAN AVE S - GATEWAY CORPORATE CENTER BUILDING #2 - PERMITS AND PLANS
12674 INTERURBAN AVE S ASSOCIATED PERMITS 13-F-119 11-F-092 CITY OF TUKWILA N4 FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 lV SITE LOCATION / A 7 4/ FIRE PROTECTION SYSTEMS PERMIT APPLICATION Date application accepted: Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** Kin Co. Assessor's Tax No.: �t Site Address: cAit art' .4i 2 Suite Number: Floor: I Tenant Name: ©, , , c • Property Owner's Name: New Tenant? - Yes ❑ - No Mailing Address: City State Zip CONTACT PERSON -if there are questions about the submittal. Q Name: Obw /l -res 04#S,D n Day Telephone: ZS - ' 1? - Y17/04 Company Name: -CIA"- /i FJ -e-- S> J J /Lt> f .. Mailing Address: I tl U � �� /� b . t- % ("t 9 gz-(1 City State Zip E-mail Address: d0h S;f-i-k fc GSM Total number of new/relocated devices or sprinkler heads: 7 Fax Number: Valuation of Project (contractor's bid price): $ / 0 L ILO Scope of Work (please provide detailed information): Co ✓1�C• / D•t 1`O K Cjn2 p{,,. c-/ SUw4-c- PERMIT APPLICATION NOTES Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Date: 5— / 3 Print Name: /04, t UI 1 . Day Telephone: 25-3 - 6/ 7 - g Y o c, Plan Permit App.doc TFD FP Form 8 12674 GATEWAY DR 13-F-119 CONFIDENTIAL A FIRE ALARM SYSTEMS BATTERY CALCULATION CHART B C D E F Form: 1/22/01 G Mi. WASHINGTONALARM DEVICE/ MODULE MODEL NUMBER QUANTITY OF DEVICE/ MODULE STANDBY CURRENT (AMPS) TOTAL STANDBY CURRENT (CxD) ALARM CURRENT (AMPS) TOTAL ALARM CURRENT (CxF) Gateway Corporate Pk -Bldg 2 CONTROL PANEL AND MODULES SK -505 1 0.00055 0 0.00055 0 Silent Knight Fire Control Panel SK5808 1 0.17 0.17 0.325 0.325 0 0 0 0 0 Silent Knight Addressable Module SD500MIM 3 0.00055 0.00165 0.023 0.069 Battery 12 VOLTS NP7-12 2 0 0 0 0 0 0 0 0 0 0 0 0 INITIATING DEVICES Smoke Detector SK -505 1 0.00055 0.00055 0.00055 0.00055 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 NOTIFICATION APPLIANCES Exterior Horn Strobe P2RHK 1 0.245 0.245 0 0 0 0 0 0 0 0 0 0 0 Sum Column For Standby Load (Amps) Multiply By Required Standby Time (24 or 60 Hours) Total Standby AH 0.172 24 4.133 (G) Sum Column For Alarm Load (Amps) Multiply By Required Alarm Time (5 min = .083) Total Alarm AH 0.640 0.083 0.576 TOTAL TOTAL REQUIRED SAFETY TOTAL TOTAL STANDBY ALARM AH AH (G+H) FACTOR SYSTEM SYSTEM AH (G) (H) (Multiply) AMPERE- AMPERE - HOURS HOURS REQUIRED PROVIDED 4.133 0.5756 I 4.708 1.3 6.121 14AH (H) ACCEPTED O Without Comments fr- As Noted in Red O Per The Attached Letter These plans have been reviewed by The Tukwila Fire revention Bureau for conformance with current City .r ndards. Acceptance is subject to errors and oizsions which do not authorize violations of adopted •:ndards and ordinances. The responsibility for the oequacy of design rests totally with the designer. ,dditions, deletions or revisions to these drawings after rots date will void this acceptance and will require a resubmittal or revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. pate: -19 - I t By: A)," / - e)(4fieoe kprvk/s. (ib tCltt dim; gi0, d Utilicul4✓' 4C(tSS. - h+ ski (noh d1 ea c.,{e41 FA c,;rc,,.l- .keec,l . • ..i,� hot Q jr 040ht, 1‘4,4":1i1,41,4 dtr' k__ RISER DIAGRAM GATEWAY BLDG 2 V To dedicated 120vac Power Supply FACP MIM To Telco To dedicated 120vac Power Supply FACP MIM V MIM TS MIM=MIM <1"S MIME Alarm panel is addressable and all devices are on an SLC loop. Each devices functions as it's own End of Line resistor. SILENT KNIGHT 5808 FIRE ALARM CONTROL PANEL SILENT KNIGHT SD505APS ADDRESSABLE SMOKE DETECTOR SILENT KNIGHT SD500MIM ADDRESSABLE INPUT MODULE SPRINKLER FLOW .SWITCH TAMPER SWITCH SYSTEM SENSOR P2RHK EXTERIOR HORN/STROBE • 1. TITLE PAGE TABLE OF CONTENTS 2. TABLE OF CONTENTS 3. MAP 4. SILENT KNIGHT (5808) ADDRESSABLE FIRE ALARM CONTROL PANEL 5. AIR PRODUCTS (SL -2000-P) DUCT SMOKE DETECTOR 6. SILENT KNIGHT (SD500-AIM) ADDRESSABLE MONITOR MODULE ACCEPTED Without Comments As Noted in Red 0 Per The Attached Letter These plans have been reviewed by The Tukwila Fire revention Bureau for c-•. iformance with current City andards. Acceptanc=t:° i subject to errors and omissions which do not autnorize violations of adopted .-tandards and ordinances. The responsibility for the =.dequacy of design rens totally with the designer. Additions; deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final•acceptanccf is subject to field test and inspection by The Tukwila Fire Prevention Bureau., Date: By: AIM .S ( C " :PAR'6 TENT t Please cit 23,: -.575-4407 and give this F' a Permit No. find exact address for shut- lown or on aoemvai. NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. failure of test will result in a Re -inspection Fee and termination of the testing