Loading...
HomeMy WebLinkAboutPP - 13900 INTERURBAN AVE S - FOSTER GOLF MAINTENANCE - PERMITS AND PLANS13900 INTERURBAN AVE S ASSOCIATED PERMITS 15-F-108 SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** Site Address: 13900 INTERURBAN AVE. S Tenant Name:FOSTER GOLF COURSE Property Owner's Name:CITY OF TUKWILA King Co. Assessor's Tax No.: 000300-0049 Suite Number: Floor: New Tenant? ❑ - Yes ® - No Mailing Address:13900 INTERURBAN AVE. S TUKWILA WA 98168 City State Zip CONTACT PERSON -if there are questions about the submittal. Name: DENNIS COATES Day Telephone: (360) 491-6320 Company Name:ALARM CENTER, INC. Mailing Address:PO BOX 3407 LACEY WA 98509 City State Zip E-mail Address:dcoates@alarmcenterinc.com Fax Number:(360) 438-4244 Contractor's City of Tukwila Business License number: BUS -0992830 Total number of new/relocated devices or sprinkler heads: 1 Valuation of Project (contractor's bid price): $ 795.00 Scope of Work (please provide detailed information): INSTALL NEW A.E.S. FIRE ALARM COMMUNICATOR AND CONNECT TO EXISTING NOTIFIER AFP -200 FIRE ALARM CONTROL UNIT. PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. N. NON BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name: DENNIS COATES Plan Permit App.doc Date: 06/25/2015 Day Telephone: (360) 481-4969 8/22/14 TFD FP Form 8 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit 0 CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 /S—F=/DB PERMIT NUMBERS Project: 6,1(MI*/ s Type of Inspection: -VA Address: Suite #: /3500 ,..._A --S Contact Person: Special Instructions: Phone No.: _pproved per applicable codes. Corrections required prior to approval. COMMENTS: AES Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector:j! _ j '(3 Date: -747 Ar Hrs.: 1.0 $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip.. Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 City of Tukwila Fire Department Fire Department Review Control #D99-0289 (512) r F9 L John W. Rants, Mayor Thomas P. Keefe, Fire Chief August 19, 1999 /35-d Re: Foster Golf Course Equipment Shed A - 13900 Interurban Avenue South Dear Sir: The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. The total number of fire extinguishers required for your establishment is calculated at one extinguisher for each 3000 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 10B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (NFPA 10, 3-1.1) Portable fire extinguishers shall be securely installed on the hanger or in the bracket supplied, placed in cabinets or wall recesses. The hanger or bracket shall be securely and properly anchored to the mounting surface in accordance with the manufacturer's instructions. The extinguisher shall be installed so that the top of the extinguisher is not more than 5 feet above the floor and the clearance between the bottom of the extinguisher and the floor shall not be less than 4 inches. Extinguishers shall be located so as to be in plain view (if at all possible), or if not in plain view, they shall be identified with a sign stating, "Fire Extinguisher", with an arrow pointing to the unit. (NFPA 10, 1-6.3) (UFC Standard 10-1) Clear access to fire extinguishers is required at all times. They may not be hidden or obstructed. (NFPA 10, 1-6.5) Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 575-4439 City of Tukwila John W Rants, Mayor Fire Department Thomas P. Keefe, Fire Chief Page number 2 Maintain fire extinguisher coverage throughout. 2. Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. Exit doors shall not be locked, chained, bolted, barred, latched or otherwise rendered unusable. All locking devices shall be of an approved type. (UFC 1207.3) Obstructions, including storage, shall not be placed in the required width of an exit, except projections as permitted by the Building Code. Exits shall not be obstructed in any manner and shall remain free of any material or matter where its presence would obstruct or render the exit hazardous. (UFC 1203) Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (UFC 1207.3) Exit hardware and marking shall meet the requirements of the Uniform Fire Code. (UFC 1207-1212) Aisles leading to required exits shall be provided from all portions of buildings. Aisles located within an accessible route of travel shall also comply with the Building Code requirements for accessibility. (UFC 1204.1) Exits shall not pass through kitchens, storerooms, restrooms, closets or spaces used for similar purposes. (UBC 1004.2.2) Combustible material shall not be stored in exits or exit enclosures. (UFC 1103.3.2.3) Exit doors shall be maintained in accordance with Section 1207. Exit doors shall be maintained in an ,operable condition. Doors installed as part of required fire assemblies shall be maintained in accordance with Section 1112.2. (UFC 1207.1) Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 575-4439 City of Tukwila John W Rants, Mayor Fire Department Thomas P. Keefe, Fire Chief Page number 3 3. A fire alarm system is required for this project. The fire alarm system shall meet the requirements of N.F.P.A. 72 and City Ordinance #1742. The installation of wiring and equipment shall be in accordance with N.F.P.A. 70, Article 760, Fire Protective Signaling Systems. (NFPA 72-1-5.5.4) Local U.L. central station supervision is required. (City Ordinance #1742) Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #1742) Remote alarm annunciation indication is required if the control panel is not visible from the main entrance. (City Ordinance #1742) When the control panel is located inside a room, the door to the room shall have a sign with one -inch letters which reads "Fire Alarm" or "Fire Alarm Control". (City Ordinance #1742) All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #1742) (UFC 1001.3) H.V.A.C. units rated at greater than 2,000 cfm require auto -shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #1742) H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air -moving equipment upon detection of smoke in the main Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 575-4439 City of Tukwila John W. Rants, Mayor Fire Department Thomas P. Keefe, Fire Chief Page number 4 supply -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (UMC 608) Fire alarm systems shall be maintained in an operative condition at all times. Fire alarm systems and their component parts shall be inspected and tested per manufacturer's specifications and N.F.P.A. 72 at a minimum frequency of every twelve months. A copy of inspection, test and maintenance records shall be forwarded to the Tukwila Fire Prevention Bureau. (NFPA 72 (7-3.2, 7-3.2.1)) (City Ordinance #1742) Dedicated fire alarm system circuit breaker(s) shall be equipped with a mechanical lockout device. (NFPA 72 (1-5.2.8.2)) 4. All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) 5. Required fire resistive construction, including occupancy separations, area separation walls, exterior walls due to location on property, fire resistive requirements based on type of construction, draft stop partitions and roof coverings shall be maintained as specified in the Building Code and Fire Code and shall be properly repaired, restored or replaced when damaged, altered, breached, penetrated, removed or improperly installed. (UFC 1111.1) Your street address must be conspicuously posted on the building and shall be plainly visible and legible from the street. (UFC 901.4.4) Every building shall be accessible to Fire Department apparatus by way of access roadways with all-weather driving surface of not less than 20' wide and 13'6" vertical clearance. Access roads in excess of 150' Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 575-4439 City of Tukwila John W. Rants, Mayor Fire Department Thomas P. Keefe, Fire Chief Page number 5 shall be provided with an approved turn -around area. Access shall be within 150' of all portions of the buildings. (City Ordinance #1846) There shall be no enclosed usable space under stairways in an exit enclosure, nor shall the open space under such stairways be used for any purpose. (UFC 1210.3) 6. Oily rags or used wiping rags impregnated with finishing materials shall be stored in approved metal containers with self-closing, tight fitting lids. Rags are to be deposited therein immediately after use. The contents are to be properly disposed of at least once daily and at the end of each shift. (UFC 4502.9.6) All compressed gas cylinders in service or in storage shall be adequately secured to prevent falling or being knocked over. (UFC 7401.7) This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. Yours truly, The Tukwila Fire Prevention Bureau cc: TFD file ncd Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 575-4439 City of Tukwila Fire Department Fire Department Review Control #D99-0288 (512) FLE John W. Rants, Mayor Thomas P. Keefe, Fire Chief August 19, 1999 Re: Foster Golf Course Equipment Shed B - 13900 Interurban Avenue South Dear Sir: The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. The total number of fire extinguishers required for your establishment is calculated at one extinguisher for each 3000 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 10B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (NFPA 10, 3-1.1) Portable fire extinguishers shall be securely installed on the hanger or in the bracket supplied, placed in cabinets or wall recesses. The hanger or bracket shall be securely and properly anchored to the mounting surface in accordance with the manufacturer's instructions. The extinguisher shall be installed so that the top of the extinguisher is not more than 5 feet above the floor and the clearance between the bottom of the extinguisher and the floor shall not be less than 4 inches. Extinguishers shall be located so as to be in plain view (if at all possible), or if not in plain view, they shall be identified with a sign stating, "Fire Extinguisher", with an arrow pointing to the unit. (NFPA 10, 1-6.3) (UFC Standard 10-1) Clear access to fire extinguishers is required at all times. They may not be hidden or obstructed. (NFPA 10, 1-6.5) Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 5754439 City of Tukwila John W. Rang Mayor Fire Department Thomas P. Keefe, Fire Chief Page number 2 Maintain fire extinguisher coverage throughout. 2. Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. Exit doors shall not be locked, chained, bolted, barred, latched or otherwise rendered unusable. All locking devices shall be of an approved type. (UFC 1207.3) Obstructions, including storage, shall not be placed in the required width of an exit, except projections as permitted by the Building Code. Exits shall not be obstructed in any manner and shall remain free of any material or matter where its presence would obstruct or render the exit hazardous. (UFC 1203) Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (UFC 1207.3) Exit hardware and marking shall meet the requirements of the Uniform Fire Code. (UFC 1207-1212) Aisles leading to required exits shall be provided from all portions of buildings. Aisles located within an accessible route of travel shall also comply with the Building Code requirements for accessibility. (UFC 1204.1) Exits shall not pass through kitchens, storerooms, restrooms, closets or spaces used for similar purposes. (UBC 1004.2.2) Combustible material shall not be stored in exits or exit enclosures. (UFC 1103.3.2.3) Exit doors shall be maintained in accordance with Section 1207. Exit doors shall be maintained in an operable condition. Doors installed as part of required fire assemblies shall be maintained in accordance with Section 1112.2. (UFC 1207.1) Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 575-4439 City of Tukwila John W. Rants, Mayor Fire Department Thomas P. Keefe, Fin? chief Page number 3 3. A fire alarm system is required for this project. The fire alarm system shall meet the requirements of N.F.P.A. 72 and City Ordinance #1742. The installation of wiring and equipment shall be in accordance with N.F.P.A. 70, Article 760, Fire Protective Signaling Systems. (NFPA 72-1-5.5.4) Local U.L. central station supervision is required. (City Ordinance #1742) Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #1742) Remote alarm annunciation indication is required if the control panel is not visible from the main entrance. (City Ordinance #1742) When the control panel is located inside a room, the door to the room shall have a sign with one -inch letters which reads "Fire Alarm" or "Fire Alarm Control". (City Ordinance #1742) All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #1742) (UFC 1001.3) H.V.A.C. units rated at greater than 2,000 cfm require auto -shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #1742) H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air -moving equipment upon detection of smoke in the main Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone (206) 575-4404 • Fax (206) 575-4439 City of Tukwila John W. Rants, Mayor Fire Department Thomas P. Keefe, Fin' Chief Page number 4 supply -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (UMC 608) Fire alarm systems shall be maintained in an operative condition at all times. Fire alarm systems and their component parts shall be inspected and tested per manufacturer's specifications and N.F.P.A. 72 at a minimum frequency of every twelve months. A copy of inspection, test and maintenance records shall be forwarded to the Tukwila Fire Prevention Bureau. (NFPA 72 (7-3.2, 7-3.2.1)) (City Ordinance #1742) Dedicated fire alarm system circuit breaker(s) shall be equipped with a mechanical lockout device. (NFPA 72 (1-5.2.8.2)) 4. All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) 5. Required fire resistive construction, including occupancy separations, area separation walls, exterior walls due to location on property, fire resistive requirements based on type of construction, draft stop partitions and roof coverings shall be maintained as specified in the Building Code and Fire Code and shall be properly repaired, restored or replaced when damaged, altered, breached, penetrated, removed or improperly installed. (UFC 1111.1) Your street address must be conspicuously posted on the building and shall be plainly visible and legible from the street. (UFC 901.4.4) Every building shall be accessible to Fire Department apparatus by way of access roadways with all-weather driving surface of not less than 20' wide and 13'6" vertical clearance. Access roads in excess of 150' Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 575-4439 City of Tukwila John W. Rants, Mayor Fire Department Thomas P. Keefe, Fire Chief Page number 5 shall be provided with an approved turn -around area. Access shall be within 150' of all portions of the buildings. (City Ordinance #1846) There shall be no enclosed usable space under stairways in an exit enclosure, nor shall the open space under such stairways be used for any purpose. (UFC 1210.3) 6. Oily rags or used wiping rags impregnated with finishing materials shall be stored in approved metal containers with self-closing, tight fitting lids. Rags are to be deposited therein immediately after use. The contents are to be properly disposed of at least once daily and at the end of each shift. (UFC 4502.9.6) All compressed gas cylinders in service or in storage shall be adequately secured to prevent falling or being knocked over. (UFC 7401.7) This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. Yours truly, The Tukwila Fire Prevention Bureau cc: TFD file ncd Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 575-4439 City of Tukwila Fire Department Fire Department Review Control #D99-0285 (512) F.LE John W. Rants, Mayor Thomas P. Keefe, Fire Chief August 19, 1999 Re: Foster Golf Course Crew Shop - 13900 Interurban Avenue South Dear Sir: The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. The total number of fire extinguishers required for your establishment is calculated at one extinguisher for each 3000 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 10B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (NFPA 10, 3-1.1) Portable fire extinguishers shall be securely installed on the hanger or in the bracket supplied, placed in cabinets or wall recesses. The hanger or bracket shall be securely and properly anchored to the mounting surface in accordance with the manufacturer's instructions. The extinguisher shall be installed so that the top of the extinguisher is not more than 5 feet above the floor and the clearance between the bottom of the extinguisher and the floor shall not be less than 4 inches. Extinguishers shall be located so as to be in plain view (if at all possible), or if not in plain view, they shall be identified with a sign stating, "Fire Extinguisher", with an arrow pointing to the unit. (NFPA 10, 1-6.3) (UFC Standard 10-1) Clear access to fire extinguishers is required at all times. They may not be hidden or obstructed. (NFPA 10, 1-6.5) Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 575-4439 City of Tukwila John W. Rants, Mayor Fire Department Thomas P. Keefe, Fire Chief Page number 2 Maintain fire extinguisher coverage throughout. 2. Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. Exit doors shall not be locked, chained, bolted, barred, latched or otherwise rendered unusable. All locking devices shall be of an approved type. (UFC 1207.3) Obstructions, including storage, shall not be placed in the required width of an exit, except projections as permitted by the Building Code. Exits shall not be obstructed in any manner and shall remain free of any material or matter where its presence would obstruct or render the exit hazardous. (UFC 1203) Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (UFC 1207.3) Exit hardware and marking shall meet the requirements of the Uniform Fire Code. (UFC 1207-1212) Aisles leading to required exits shall be provided from all portions of buildings. Aisles located within an accessible route of travel shall also comply with the Building Code requirements for accessibility. (UFC 1204.1) Exits shall not pass through kitchens, storerooms, restrooms, closets or spaces used for similar purposes. (UBC 1004.2.2) Combustible material shall not be stored in exits or exit enclosures. (UFC 1103.3.2.3) Exit doors shall be maintainedin accordance with Section 1207. Exit doors shall be maintained in an operable condition. Doors installed as part of required fire assemblies shall be maintained in accordance with Section 1112.2. (UFC 1207.1) Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone (206) 575-4404 • Fax (206) 575-4439 City of Tukwila John W. Rants, Mayor Fire Department Thomas P. Keefe, Fire Chief Page number 3 3. A fire alarm system is required for this project. The fire alarm system shall meet the requirements of N.F.P.A. 72 and City Ordinance #1742. The installation of wiring and equipment shall be in accordance with N.F.P.A. 70, Article 760, Fire Protective Signaling Systems. (NFPA 72-1-5.5.4) Local U.L. central station supervision is required. (City Ordinance #1742) Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #1742) Remote alarm annunciation indication is required if the control panel is not visible from the main entrance. (City Ordinance #1742) When the control panel is located inside a room, the door to the room shall have a sign with one -inch letters which reads "Fire Alarm" or "Fire Alarm Control". (City Ordinance #1742) All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #1742) (UFC 1001.3) H.V.A.C. units rated at greater than 2,000 cfm require auto -shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #1742) H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air -moving equipment upon detection of smoke in the main Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 575-4439 City of Tukwila John W. Rants, Mayor Fire Department Thomas P. Keefe, Fire Chtef Page number 4 supply -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (UMC 608) Fire alarm systems shall be maintained in an operative condition at all times. Fire alarm systems and their component parts shall be inspected and tested per manufacturer's specifications and N.F.P.A. 72 at a minimum frequency of every twelve months. A copy of inspection, test and maintenance records shall be forwarded to the Tukwila Fire Prevention Bureau. (NFPA 72 (7-3.2, 7-3.2.1)) (City Ordinance #1742) Dedicated fire alarm system circuit breaker(s) shall be equipped with a mechanical lockout device. (NFPA 72 (1-5.2.8.2)) 4. All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) 5. Required fire resistive construction, including occupancy separations, area separation walls, exterior walls due to location on property, fire resistive requirements based on type of construction, draft stop partitions and roof coverings shall be maintained as specified in the Building Code and Fire Code and shall be properly repaired, restored or replaced when damaged, altered, breached, penetrated, removed or improperly installed. (UFC 1111.1) Your street address must be conspicuously posted on the building and shall be plainly visible and legible from the street. (UFC 901.4.4) Every building shall be accessible to Fire Department apparatus by way of access roadways with all-weather driving surface of not less than 20' wide and 13'6" vertical clearance. Access roads in excess of 150' Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 575-4439 City of Tukwila Fire Department Page number 5 John W. Rants, Mayor Thomas P. Keefe, Fine Chief shall be provided with an approved turn -around area. Access shall be within 150' of all portions of the buildings. (City Ordinance #1846) There shall be no enclosed usable space under stairways in an exit enclosure, nor shall the open space under such stairways be used for any purpose. (UFC 1210.3) 6. Oily rags or used wiping rags impregnated with finishing materials shall be stored in approved metal containers with self-closing, tight fitting lids. Rags are to be deposited therein immediately after use. The contents are to be properly disposed of at least once daily and at the end of each shift. (UFC 4502.9.6) All compressed gas cylinders in service or in storage shall be adequately secured to prevent falling or being knocked over. (UFC 7401.7) 7. This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval. of such condition or violation. Yours truly, The Tukwila Fire Prevention Bureau cc: TFD file ncd Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 575-4439 07/2?/2015 09:47 3604384244 LACEY OPS TUKWILA FIRE MARSHAL'S OFFICE Phone: 206-575-4407 • Fax: 206-575-4439 • Email: FircMarshal if:Aukwilawa.gov CONTRACTORS MATERIAL AND TEST CERTIFICATE FIRE ALARM AND FIRE DETECTION SYSTEMS Fire alarm System is ready for Fire Department acceptance testing. Failure of test will result in termination of the testing and additional fees will be assessed. Contractor is responsible for supplying manpower for Final Acceptance Test with two-way communications. Date �— L3 — /.S Permit 15--F - /0r Property Address /3 qc o �1.1.L Y 5 Suite # Citi _TUKWILA Zip Code ej$Y‘f� Name of-Facilit> Occupied as Owner or Representative Installing Company lk 1.49k Phone= zC0571 — Cfg: Installing Contractors Address `7�.-2t 3 C its %.,�-,�� Phonegoo 3 sy GS S5� Installers NA (PREM 1') License and 'or Certificate )1-leo/rid- 85'1 General Contractor Electrical Contractor F:\C'P Equipment Manufacturer �p�/-(►� ►� Rtodei This s> stern has been installer!_ pre -tested and operates in accordance with the standards listed bclo‘% and was inspected b> On (date) and includes the devices listed nn back. Circle all that apply: NEPA 72. Chapter 1 2 -' : 6 7 and or IFC' SEC 907 NFPA 70. National Electrical Code. Article 760 Manufacturer's Instructions \1anuFacturer's Instructions Other (specif% ) Tukwila C it' Ordinance Numbers 2050. 2051 L'[.. Central Station !genitor A1a✓p►1 (t�u+.4cr stem is monitored bN SIGNED Date S� stem Firmware: Installed %ersion Checksum Initial program Installation Revisions and Reasons Date Date Programmed tiv PAGE 01/02 07/2/2015 09:47 3604384244 EQUIPMENT NSTALLED AND TESTED: Control Panel Manual Station Smoke Detectors Heat Detectors Duct Detectors A/V Devices Audio Devices Visual Device Aute l.)oor Release Trouble Indictors Batteries of of of of of Readings Batter% C.icnerator of 1IVAC' Controls of Fire Alarm Dialer 1 of Monitored byJpv."yvt Annunciator Make/Model Make/Model Make/Model Make/Model Make!Mode 1 Make/Model Make/Model Make/Model MakelModel Make/Model Full Load LACEY OPS PAGE 02/02 Make/Model I\1 Ike/Model Charge _L Make/ModelAES — 77 ir of Make!Model Sprinkler System. (Fire Alarm Water Flom S«. of Vale Tamper Sw. of PIV _ of Elc . Alarm Bell ~^ of connections only 1 Make 'Model Makt'Mudel Make'Model Make!Mode1 Automatic time Dela. of Water Flow Alarm seconds, None Installed �)o you meet audible'%isihle requirements or WAC 51-20. IEC SEC 907,. and. Or ?FPA 72 Chapter 6" Yes No I opt or alarm S) stem on emcrgtnc\ power- satisfactory.' Yes No Witnessed itnessedl b\. "Title C onuncr ts: Date l=ire ,\Iurm CL!rtiticaic.duc RAN iscd: 6:17 14 TED FP Firm a 110 Technical Specifications 7794 • Transmits full data to AES-MultiNet receiver using Contact ID or Pulse formats Formats Supported: Contact ID, Pulse 3+1, Pulse 4+1, Pulse 4+2, Modem Ile, and Modem 111a2 I/O CONNECTIONS • AES subscriber - data and power • Handheld/PC programming port • Plain Old Telephone Service (POTS) incoming phone line • Phone output connection from alarm panel • Trouble output (form C relay) SIZE • 4 7/8 in. x 5 in. (12.3 cm x 12.7 cm) Power Requirements • 12 VDC nominal, primary and backup power provided by the AES RF Transceiver Unit Current Consumption 350 mA nominal 7795 The 7795 AES-lntelliPro is a kit that includes the 7794 module and 7762 Hardware Supervisory module. *For model 7794, please see Technical Specifications above The 7762 is a Hardware Supervisory Module. I/O CONNECTIONS • 31 - AES 7794 (J2) or Subscriber (31)- data and power • Input for Subscriber J4 Output • Input for AES 7740 Local Annunciator - data and power • AES 7740/AES 7794 Trouble Output to Subscriber input zone SIZE: • 2 1/2 in. x 4 15/16 in. (6.3 cm x 12.5 cm) WEIGHT: • 0.25 pounds (0.11 kilograms) POWER INPUT: • 12VDC nominal, power supplied from AES 7794 module or AES 7744F/7788F Subscribers CURRENT CONSUMPTION • 40 mA average; 100 mA peak Full Alarm Signal Data No alarm data is lost converting fire alarm signals from over Public Switched Telephone Network (PSTN) to transmission over AES-IntelliNet alarm communications. AES lntelliPro Fire'e" Series modules transmit full alarm data captured off the FACP's digital communicator including alarm zone identification and event codes. AES-IntelliPro Fire will work in new fire alarm system installations to substitute phone line connections as well as retrofit existing installed fire alarm systems. AES-lntelliPro Fire supports most alarm communication protocols including Contact ID, Pulse, and Bosch Modem Ile and Modem 111a2. Flexible Installation Options Existing installed Subscribers can easily be upgraded to communicate full alarm data from a FACP's digital dialer over AES-IntelliNet networks. For these applications, models 7794 and 7795 are available as field installed modules that come with all needed hardware to upgrade an existing AES Subscriber. For new installations, AES Fire Subscribers are available equipped with the right AES-IntelliPro Fire module for the application. 7794 AES-lntelliPro Fire Full Data Module. UL listed for supplemental communication with fire radios 7795 AES-IntelliPro Fire Full Data Module (7794) with 7762 Hardware Supervisory Module. UL listed for primary standalone communication with fire radios 7744F-ULP 7788F-ULP 7744F-ULP-P 7788F-ULP-P 7788F-C-ULP 4x4 Zone Fire Subscriber, 4 Reversing Polarity, 4 Supervised, includes 7794 AES-lntelliPro Fire, Red Enclosure 8 Zone Fire Subscriber, 8 Supervised Zones, includes 7794 AES-IntelliPro Fire, Red Enclosure 4x4 Zone Fire Subscriber, 4 Reversing Polarity, 4 Supervised, includes 7795 AES-lntelliPro Fire, Red Enclosure 8 Zone Fire Subscriber, 8 Supervised Zones, includes 7795 AES-lntelliPro Fire, Red Enclosure 8 Zone Fire Subscriber with 7794 AES-lntelliPro Fire, Red Enclosure (ULC) Canada 7762 ' Add-on module provides power/supervision for 7794 AES-InteltiPro Fire module and AES 7740 local trouble annunciator. Included with 7795 AES-lntelliPro Fire and AES 7742 local annunciator kit for Subscriber Specifications Subject to Change Without Notice USTED us I NFPN NetOne ACCEPTED p Without Comments As Noted in Red p Per The Attached Letter These plans have been reviewed by The Tukwila Fire prevention Bureau for conformance with current City randards. Acceptance is subject to errors and ;missions which do not authorize violations of adopted ;andards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance Is subject to field test and inspection by The Tukwila Flre Prevention Bureau. Date: 7-1 t�' eiNivi& 5$..414 k+. 4So c. A -ES aid 0-.644;6,0 Gtvt.,.; F- w/ 6yrak— 11441/ clgw.ro - NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testinc§ of any Fire Alarm and C),. ,,,cion Systems. Failure of test will result in a Re -inspection Fee and 4-prrnination of the testing KWILA i"RE DEPARTMENT call 206-575-4407 and jsS thiS Fire o No. „Ind exact add ss for shut- down or restoration approval.