FIRE PROTECTION SYSTEMS PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
**PLEASE PRINT**
Site Address: 13900 INTERURBAN AVE. S
Tenant Name:FOSTER GOLF COURSE
Property Owner's Name:CITY OF TUKWILA
King Co. Assessor's Tax No.: 000300-0049
Suite Number: Floor:
New Tenant? ❑ - Yes ® - No
Mailing Address:13900 INTERURBAN AVE. S TUKWILA WA 98168
City State Zip
CONTACT PERSON -if there are questions about the submittal.
Name: DENNIS COATES Day Telephone: (360) 491-6320
Company Name:ALARM CENTER, INC.
Mailing Address:PO BOX 3407 LACEY WA 98509
City State Zip
E-mail Address:dcoates@alarmcenterinc.com Fax Number:(360) 438-4244
Contractor's City of Tukwila Business License number: BUS -0992830
Total number of new/relocated devices or sprinkler heads: 1
Valuation of Project (contractor's bid price): $ 795.00
Scope of Work (please provide detailed information): INSTALL NEW A.E.S. FIRE ALARM COMMUNICATOR AND
CONNECT TO EXISTING NOTIFIER AFP -200 FIRE ALARM CONTROL UNIT.
PERMIT APPLICATION NOTES
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be
reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules.
Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit
is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or
abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in
writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing
and justifiable cause demonstrated.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE
UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY
FOR THIS PERMIT. N.
NON
BUILDING OWNER OR AUTHORIZED AGENT:
Signature:
Print Name: DENNIS COATES
Plan Permit App.doc
Date: 06/25/2015
Day Telephone: (360) 481-4969
8/22/14 TFD FP Form 8
INSPECTION NUMBER
INSPECTION RECORD
Retain a copy with permit
0
CITY OF TUKWILA FIRE DEPARTMENT
206-575-4407
/S—F=/DB
PERMIT NUMBERS
Project:
6,1(MI*/ s
Type of Inspection:
-VA
Address:
Suite #: /3500 ,..._A --S
Contact Person:
Special Instructions:
Phone No.:
_pproved per applicable codes.
Corrections required prior to approval.
COMMENTS:
AES
Needs Shift Inspection:
Sprinklers:
Fire Alarm:
Hood & Duct:
Monitor:
Pre -Fire:
Permits:
Occupancy Type:
Inspector:j! _ j '(3
Date: -747 Ar
Hrs.: 1.0
$100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from
the City of Tukwila Finance Department. Call to schedule a reinspection.
Billing Address
Attn:
Company Name:
Address:
City:
State:
Zip..
Word/Inspection Record Form.Doc
3/14/14
T.F.D. Form F.P. 113
City of Tukwila
Fire Department
Fire Department Review
Control #D99-0289
(512)
r
F9 L
John W. Rants, Mayor
Thomas P. Keefe, Fire Chief
August 19, 1999
/35-d
Re: Foster Golf Course Equipment Shed A - 13900 Interurban
Avenue South
Dear Sir:
The attached set of building plans have been reviewed by
The Fire Prevention Bureau and are acceptable with the
following concerns:
1. The total number of fire extinguishers required for
your establishment is calculated at one extinguisher for
each 3000 sq. ft. of area. The extinguisher(s) should be
of the "All Purpose" (2A, 10B:C) dry chemical type. Travel
distance to any fire extinguisher must be 75' or less.
(NFPA 10, 3-1.1)
Portable fire extinguishers shall be securely
installed on the hanger or in the bracket supplied,
placed in cabinets or wall recesses. The hanger or
bracket shall be securely and properly anchored to the
mounting surface in accordance with the manufacturer's
instructions. The extinguisher shall be installed so
that the top of the extinguisher is not more than 5
feet above the floor and the clearance between the
bottom of the extinguisher and the floor shall not be
less than 4 inches.
Extinguishers shall be located so as to be in plain
view (if at all possible), or if not in plain view,
they shall be identified with a sign stating, "Fire
Extinguisher", with an arrow pointing to the unit.
(NFPA 10, 1-6.3) (UFC Standard 10-1)
Clear access to fire extinguishers is required at all
times. They may not be hidden or obstructed. (NFPA
10, 1-6.5)
Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 575-4439
City of Tukwila
John W Rants, Mayor
Fire Department Thomas P. Keefe, Fire Chief
Page number 2
Maintain fire extinguisher coverage throughout.
2. Exit doors shall be openable from the inside without
the use of a key or any special knowledge or effort. Exit
doors shall not be locked, chained, bolted, barred, latched
or otherwise rendered unusable. All locking devices shall
be of an approved type. (UFC 1207.3)
Obstructions, including storage, shall not be placed
in the required width of an exit, except projections
as permitted by the Building Code. Exits shall not be
obstructed in any manner and shall remain free of any
material or matter where its presence would obstruct
or render the exit hazardous. (UFC 1203)
Dead bolts are not allowed on auxiliary exit doors
unless the dead bolt is automatically retracted when
the door handle is engaged from inside the tenant
space. (UFC 1207.3)
Exit hardware and marking shall meet the requirements
of the Uniform Fire Code. (UFC 1207-1212)
Aisles leading to required exits shall be provided
from all portions of buildings. Aisles located within
an accessible route of travel shall also comply with
the Building Code requirements for accessibility.
(UFC 1204.1)
Exits shall not pass through kitchens, storerooms,
restrooms, closets or spaces used for similar
purposes. (UBC 1004.2.2)
Combustible material shall not be stored in exits or
exit enclosures. (UFC 1103.3.2.3)
Exit doors shall be maintained in accordance with
Section 1207. Exit doors shall be maintained in an
,operable condition. Doors installed as part of
required fire assemblies shall be maintained in
accordance with Section 1112.2. (UFC 1207.1)
Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 575-4439
City of Tukwila
John W Rants, Mayor
Fire Department Thomas P. Keefe, Fire Chief
Page number 3
3. A fire alarm system is required for this project. The
fire alarm system shall meet the requirements of N.F.P.A.
72 and City Ordinance #1742.
The installation of wiring and equipment shall be in
accordance with N.F.P.A. 70, Article 760, Fire
Protective Signaling Systems. (NFPA 72-1-5.5.4)
Local U.L. central station supervision is required.
(City Ordinance #1742)
Remote indicator lights are required on all above
ceiling smoke detectors. (City Ordinance #1742)
Remote alarm annunciation indication is required if
the control panel is not visible from the main
entrance. (City Ordinance #1742)
When the control panel is located inside a room, the
door to the room shall have a sign with one -inch
letters which reads "Fire Alarm" or "Fire Alarm
Control". (City Ordinance #1742)
All new fire alarm systems or modifications to
existing systems shall have the written approval of
The Tukwila Fire Prevention Bureau. No work shall
commence until a fire department permit has been
obtained. (City Ordinance #1742) (UFC 1001.3)
H.V.A.C. units rated at greater than 2,000 cfm require
auto -shutdown devices. These devices shall be
separately zoned in the alarm panel and local U.L.
central station supervision is required. (City
Ordinance #1742)
H.V.A.C. systems supplying air in excess of 2,000
cubic feet per minute to enclosed spaces within
buildings shall be equipped with an automatic shutoff.
Automatic shutoff shall be accomplished by
interrupting the power source of the air -moving
equipment upon detection of smoke in the main
Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 575-4439
City of Tukwila
John W. Rants, Mayor
Fire Department Thomas P. Keefe, Fire Chief
Page number 4
supply -air duct served by such equipment. Smoke
detectors shall be labeled by an approved agency for
air -duct installation and shall be installed in
accordance with the manufacturer's installation
instructions. (UMC 608)
Fire alarm systems shall be maintained in an operative
condition at all times. Fire alarm systems and their
component parts shall be inspected and tested per
manufacturer's specifications and N.F.P.A. 72 at a
minimum frequency of every twelve months. A copy of
inspection, test and maintenance records shall be
forwarded to the Tukwila Fire Prevention Bureau.
(NFPA 72 (7-3.2, 7-3.2.1)) (City Ordinance #1742)
Dedicated fire alarm system circuit breaker(s) shall
be equipped with a mechanical lockout device. (NFPA
72 (1-5.2.8.2))
4. All electrical work and equipment shall conform
strictly to the standards of The National Electrical Code.
(NFPA 70)
5. Required fire resistive construction, including
occupancy separations, area separation walls, exterior
walls due to location on property, fire resistive
requirements based on type of construction, draft stop
partitions and roof coverings shall be maintained as
specified in the Building Code and Fire Code and shall be
properly repaired, restored or replaced when damaged,
altered, breached, penetrated, removed or improperly
installed. (UFC 1111.1)
Your street address must be conspicuously posted on
the building and shall be plainly visible and legible
from the street. (UFC 901.4.4)
Every building shall be accessible to Fire Department
apparatus by way of access roadways with all-weather
driving surface of not less than 20' wide and 13'6"
vertical clearance. Access roads in excess of 150'
Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 575-4439
City of Tukwila
John W. Rants, Mayor
Fire Department Thomas P. Keefe, Fire Chief
Page number 5
shall be provided with an approved turn -around area.
Access shall be within 150' of all portions of the
buildings. (City Ordinance #1846)
There shall be no enclosed usable space under
stairways in an exit enclosure, nor shall the open
space under such stairways be used for any purpose.
(UFC 1210.3)
6. Oily rags or used wiping rags impregnated with
finishing materials shall be stored in approved metal
containers with self-closing, tight fitting lids. Rags are
to be deposited therein immediately after use. The
contents are to be properly disposed of at least once daily
and at the end of each shift. (UFC 4502.9.6)
All compressed gas cylinders in service or in storage
shall be adequately secured to prevent falling or
being knocked over. (UFC 7401.7)
This review limited to speculative tenant space only -
special fire permits may be necessary depending on detailed
description of intended use.
Any overlooked hazardous condition and/or violation of the
adopted Fire or Building Codes does not imply approval of
such condition or violation.
Yours truly,
The Tukwila Fire Prevention Bureau
cc: TFD file
ncd
Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 575-4439
City of Tukwila
Fire Department
Fire Department Review
Control #D99-0288
(512)
FLE
John W. Rants, Mayor
Thomas P. Keefe, Fire Chief
August 19, 1999
Re: Foster Golf Course Equipment Shed B - 13900 Interurban
Avenue South
Dear Sir:
The attached set of building plans have been reviewed by
The Fire Prevention Bureau and are acceptable with the
following concerns:
1. The total number of fire extinguishers required for
your establishment is calculated at one extinguisher for
each 3000 sq. ft. of area. The extinguisher(s) should be
of the "All Purpose" (2A, 10B:C) dry chemical type. Travel
distance to any fire extinguisher must be 75' or less.
(NFPA 10, 3-1.1)
Portable fire extinguishers shall be securely
installed on the hanger or in the bracket supplied,
placed in cabinets or wall recesses. The hanger or
bracket shall be securely and properly anchored to the
mounting surface in accordance with the manufacturer's
instructions. The extinguisher shall be installed so
that the top of the extinguisher is not more than 5
feet above the floor and the clearance between the
bottom of the extinguisher and the floor shall not be
less than 4 inches.
Extinguishers shall be located so as to be in plain
view (if at all possible), or if not in plain view,
they shall be identified with a sign stating, "Fire
Extinguisher", with an arrow pointing to the unit.
(NFPA 10, 1-6.3) (UFC Standard 10-1)
Clear access to fire extinguishers is required at all
times. They may not be hidden or obstructed. (NFPA
10, 1-6.5)
Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 5754439
City of Tukwila
John W. Rang Mayor
Fire Department Thomas P. Keefe, Fire Chief
Page number 2
Maintain fire extinguisher coverage throughout.
2. Exit doors shall be openable from the inside without
the use of a key or any special knowledge or effort. Exit
doors shall not be locked, chained, bolted, barred, latched
or otherwise rendered unusable. All locking devices shall
be of an approved type. (UFC 1207.3)
Obstructions, including storage, shall not be placed
in the required width of an exit, except projections
as permitted by the Building Code. Exits shall not be
obstructed in any manner and shall remain free of any
material or matter where its presence would obstruct
or render the exit hazardous. (UFC 1203)
Dead bolts are not allowed on auxiliary exit doors
unless the dead bolt is automatically retracted when
the door handle is engaged from inside the tenant
space. (UFC 1207.3)
Exit hardware and marking shall meet the requirements
of the Uniform Fire Code. (UFC 1207-1212)
Aisles leading to required exits shall be provided
from all portions of buildings. Aisles located within
an accessible route of travel shall also comply with
the Building Code requirements for accessibility.
(UFC 1204.1)
Exits shall not pass through kitchens, storerooms,
restrooms, closets or spaces used for similar
purposes. (UBC 1004.2.2)
Combustible material shall not be stored in exits or
exit enclosures. (UFC 1103.3.2.3)
Exit doors shall be maintained in accordance with
Section 1207. Exit doors shall be maintained in an
operable condition. Doors installed as part of
required fire assemblies shall be maintained in
accordance with Section 1112.2. (UFC 1207.1)
Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 575-4439
City of Tukwila
John W. Rants, Mayor
Fire Department Thomas P. Keefe, Fin? chief
Page number 3
3. A fire alarm system is required for this project. The
fire alarm system shall meet the requirements of N.F.P.A.
72 and City Ordinance #1742.
The installation of wiring and equipment shall be in
accordance with N.F.P.A. 70, Article 760, Fire
Protective Signaling Systems. (NFPA 72-1-5.5.4)
Local U.L. central station supervision is required.
(City Ordinance #1742)
Remote indicator lights are required on all above
ceiling smoke detectors. (City Ordinance #1742)
Remote alarm annunciation indication is required if
the control panel is not visible from the main
entrance. (City Ordinance #1742)
When the control panel is located inside a room, the
door to the room shall have a sign with one -inch
letters which reads "Fire Alarm" or "Fire Alarm
Control". (City Ordinance #1742)
All new fire alarm systems or modifications to
existing systems shall have the written approval of
The Tukwila Fire Prevention Bureau. No work shall
commence until a fire department permit has been
obtained. (City Ordinance #1742) (UFC 1001.3)
H.V.A.C. units rated at greater than 2,000 cfm require
auto -shutdown devices. These devices shall be
separately zoned in the alarm panel and local U.L.
central station supervision is required. (City
Ordinance #1742)
H.V.A.C. systems supplying air in excess of 2,000
cubic feet per minute to enclosed spaces within
buildings shall be equipped with an automatic shutoff.
Automatic shutoff shall be accomplished by
interrupting the power source of the air -moving
equipment upon detection of smoke in the main
Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone (206) 575-4404 • Fax (206) 575-4439
City of Tukwila
John W. Rants, Mayor
Fire Department Thomas P. Keefe, Fin' Chief
Page number 4
supply -air duct served by such equipment. Smoke
detectors shall be labeled by an approved agency for
air -duct installation and shall be installed in
accordance with the manufacturer's installation
instructions. (UMC 608)
Fire alarm systems shall be maintained in an operative
condition at all times. Fire alarm systems and their
component parts shall be inspected and tested per
manufacturer's specifications and N.F.P.A. 72 at a
minimum frequency of every twelve months. A copy of
inspection, test and maintenance records shall be
forwarded to the Tukwila Fire Prevention Bureau.
(NFPA 72 (7-3.2, 7-3.2.1)) (City Ordinance #1742)
Dedicated fire alarm system circuit breaker(s) shall
be equipped with a mechanical lockout device. (NFPA
72 (1-5.2.8.2))
4. All electrical work and equipment shall conform
strictly to the standards of The National Electrical Code.
(NFPA 70)
5. Required fire resistive construction, including
occupancy separations, area separation walls, exterior
walls due to location on property, fire resistive
requirements based on type of construction, draft stop
partitions and roof coverings shall be maintained as
specified in the Building Code and Fire Code and shall be
properly repaired, restored or replaced when damaged,
altered, breached, penetrated, removed or improperly
installed. (UFC 1111.1)
Your street address must be conspicuously posted on
the building and shall be plainly visible and legible
from the street. (UFC 901.4.4)
Every building shall be accessible to Fire Department
apparatus by way of access roadways with all-weather
driving surface of not less than 20' wide and 13'6"
vertical clearance. Access roads in excess of 150'
Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 575-4439
City of Tukwila
John W. Rants, Mayor
Fire Department Thomas P. Keefe, Fire Chief
Page number 5
shall be provided with an approved turn -around area.
Access shall be within 150' of all portions of the
buildings. (City Ordinance #1846)
There shall be no enclosed usable space under
stairways in an exit enclosure, nor shall the open
space under such stairways be used for any purpose.
(UFC 1210.3)
6. Oily rags or used wiping rags impregnated with
finishing materials shall be stored in approved metal
containers with self-closing, tight fitting lids. Rags are
to be deposited therein immediately after use. The
contents are to be properly disposed of at least once daily
and at the end of each shift. (UFC 4502.9.6)
All compressed gas cylinders in service or in storage
shall be adequately secured to prevent falling or
being knocked over. (UFC 7401.7)
This review limited to speculative tenant space only -
special fire permits may be necessary depending on detailed
description of intended use.
Any overlooked hazardous condition and/or violation of the
adopted Fire or Building Codes does not imply approval of
such condition or violation.
Yours truly,
The Tukwila Fire Prevention Bureau
cc: TFD file
ncd
Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 575-4439
City of Tukwila
Fire Department
Fire Department Review
Control #D99-0285
(512)
F.LE
John W. Rants, Mayor
Thomas P. Keefe, Fire Chief
August 19, 1999
Re: Foster Golf Course Crew Shop - 13900 Interurban Avenue
South
Dear Sir:
The attached set of building plans have been reviewed by
The Fire Prevention Bureau and are acceptable with the
following concerns:
1. The total number of fire extinguishers required for
your establishment is calculated at one extinguisher for
each 3000 sq. ft. of area. The extinguisher(s) should be
of the "All Purpose" (2A, 10B:C) dry chemical type. Travel
distance to any fire extinguisher must be 75' or less.
(NFPA 10, 3-1.1)
Portable fire extinguishers shall be securely
installed on the hanger or in the bracket supplied,
placed in cabinets or wall recesses. The hanger or
bracket shall be securely and properly anchored to the
mounting surface in accordance with the manufacturer's
instructions. The extinguisher shall be installed so
that the top of the extinguisher is not more than 5
feet above the floor and the clearance between the
bottom of the extinguisher and the floor shall not be
less than 4 inches.
Extinguishers shall be located so as to be in plain
view (if at all possible), or if not in plain view,
they shall be identified with a sign stating, "Fire
Extinguisher", with an arrow pointing to the unit.
(NFPA 10, 1-6.3) (UFC Standard 10-1)
Clear access to fire extinguishers is required at all
times. They may not be hidden or obstructed. (NFPA
10, 1-6.5)
Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 575-4439
City of Tukwila
John W. Rants, Mayor
Fire Department Thomas P. Keefe, Fire Chief
Page number 2
Maintain fire extinguisher coverage throughout.
2. Exit doors shall be openable from the inside without
the use of a key or any special knowledge or effort. Exit
doors shall not be locked, chained, bolted, barred, latched
or otherwise rendered unusable. All locking devices shall
be of an approved type. (UFC 1207.3)
Obstructions, including storage, shall not be placed
in the required width of an exit, except projections
as permitted by the Building Code. Exits shall not be
obstructed in any manner and shall remain free of any
material or matter where its presence would obstruct
or render the exit hazardous. (UFC 1203)
Dead bolts are not allowed on auxiliary exit doors
unless the dead bolt is automatically retracted when
the door handle is engaged from inside the tenant
space. (UFC 1207.3)
Exit hardware and marking shall meet the requirements
of the Uniform Fire Code. (UFC 1207-1212)
Aisles leading to required exits shall be provided
from all portions of buildings. Aisles located within
an accessible route of travel shall also comply with
the Building Code requirements for accessibility.
(UFC 1204.1)
Exits shall not pass through kitchens, storerooms,
restrooms, closets or spaces used for similar
purposes. (UBC 1004.2.2)
Combustible material shall not be stored in exits or
exit enclosures. (UFC 1103.3.2.3)
Exit doors shall be maintainedin accordance with
Section 1207. Exit doors shall be maintained in an
operable condition. Doors installed as part of
required fire assemblies shall be maintained in
accordance with Section 1112.2. (UFC 1207.1)
Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone (206) 575-4404 • Fax (206) 575-4439
City of Tukwila
John W. Rants, Mayor
Fire Department Thomas P. Keefe, Fire Chief
Page number 3
3. A fire alarm system is required for this project. The
fire alarm system shall meet the requirements of N.F.P.A.
72 and City Ordinance #1742.
The installation of wiring and equipment shall be in
accordance with N.F.P.A. 70, Article 760, Fire
Protective Signaling Systems. (NFPA 72-1-5.5.4)
Local U.L. central station supervision is required.
(City Ordinance #1742)
Remote indicator lights are required on all above
ceiling smoke detectors. (City Ordinance #1742)
Remote alarm annunciation indication is required if
the control panel is not visible from the main
entrance. (City Ordinance #1742)
When the control panel is located inside a room, the
door to the room shall have a sign with one -inch
letters which reads "Fire Alarm" or "Fire Alarm
Control". (City Ordinance #1742)
All new fire alarm systems or modifications to
existing systems shall have the written approval of
The Tukwila Fire Prevention Bureau. No work shall
commence until a fire department permit has been
obtained. (City Ordinance #1742) (UFC 1001.3)
H.V.A.C. units rated at greater than 2,000 cfm require
auto -shutdown devices. These devices shall be
separately zoned in the alarm panel and local U.L.
central station supervision is required. (City
Ordinance #1742)
H.V.A.C. systems supplying air in excess of 2,000
cubic feet per minute to enclosed spaces within
buildings shall be equipped with an automatic shutoff.
Automatic shutoff shall be accomplished by
interrupting the power source of the air -moving
equipment upon detection of smoke in the main
Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 575-4439
City of Tukwila
John W. Rants, Mayor
Fire Department Thomas P. Keefe, Fire Chtef
Page number 4
supply -air duct served by such equipment. Smoke
detectors shall be labeled by an approved agency for
air -duct installation and shall be installed in
accordance with the manufacturer's installation
instructions. (UMC 608)
Fire alarm systems shall be maintained in an operative
condition at all times. Fire alarm systems and their
component parts shall be inspected and tested per
manufacturer's specifications and N.F.P.A. 72 at a
minimum frequency of every twelve months. A copy of
inspection, test and maintenance records shall be
forwarded to the Tukwila Fire Prevention Bureau.
(NFPA 72 (7-3.2, 7-3.2.1)) (City Ordinance #1742)
Dedicated fire alarm system circuit breaker(s) shall
be equipped with a mechanical lockout device. (NFPA
72 (1-5.2.8.2))
4. All electrical work and equipment shall conform
strictly to the standards of The National Electrical Code.
(NFPA 70)
5. Required fire resistive construction, including
occupancy separations, area separation walls, exterior
walls due to location on property, fire resistive
requirements based on type of construction, draft stop
partitions and roof coverings shall be maintained as
specified in the Building Code and Fire Code and shall be
properly repaired, restored or replaced when damaged,
altered, breached, penetrated, removed or improperly
installed. (UFC 1111.1)
Your street address must be conspicuously posted on
the building and shall be plainly visible and legible
from the street. (UFC 901.4.4)
Every building shall be accessible to Fire Department
apparatus by way of access roadways with all-weather
driving surface of not less than 20' wide and 13'6"
vertical clearance. Access roads in excess of 150'
Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 575-4439
City of Tukwila
Fire Department
Page number 5
John W. Rants, Mayor
Thomas P. Keefe, Fine Chief
shall be provided with an approved turn -around area.
Access shall be within 150' of all portions of the
buildings. (City Ordinance #1846)
There shall be no enclosed usable space under
stairways in an exit enclosure, nor shall the open
space under such stairways be used for any purpose.
(UFC 1210.3)
6. Oily rags or used wiping rags impregnated with
finishing materials shall be stored in approved metal
containers with self-closing, tight fitting lids. Rags are
to be deposited therein immediately after use. The
contents are to be properly disposed of at least once daily
and at the end of each shift. (UFC 4502.9.6)
All compressed gas cylinders in service or in storage
shall be adequately secured to prevent falling or
being knocked over. (UFC 7401.7)
7. This review limited to speculative tenant space only -
special fire permits may be necessary depending on detailed
description of intended use.
Any overlooked hazardous condition and/or violation of the
adopted Fire or Building Codes does not imply approval. of
such condition or violation.
Yours truly,
The Tukwila Fire Prevention Bureau
cc: TFD file
ncd
Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 575-4439
07/2?/2015 09:47 3604384244
LACEY OPS
TUKWILA FIRE MARSHAL'S OFFICE
Phone: 206-575-4407 • Fax: 206-575-4439 • Email: FircMarshal if:Aukwilawa.gov
CONTRACTORS MATERIAL AND TEST CERTIFICATE
FIRE ALARM AND FIRE DETECTION SYSTEMS
Fire alarm System is ready for Fire Department acceptance testing. Failure of test will result in
termination of the testing and additional fees will be assessed. Contractor is responsible for
supplying manpower for Final Acceptance Test with two-way communications.
Date �— L3 — /.S
Permit 15--F - /0r
Property Address /3 qc o �1.1.L Y 5 Suite #
Citi _TUKWILA Zip Code ej$Y‘f�
Name of-Facilit>
Occupied as
Owner or Representative
Installing Company
lk 1.49k Phone= zC0571 — Cfg:
Installing Contractors Address `7�.-2t 3
C its %.,�-,�� Phonegoo 3 sy GS S5�
Installers NA (PREM 1')
License and 'or Certificate )1-leo/rid- 85'1
General Contractor
Electrical Contractor
F:\C'P Equipment Manufacturer �p�/-(►� ►� Rtodei
This s> stern has been installer!_ pre -tested and operates in accordance with the standards listed bclo‘% and
was inspected b>
On (date) and includes the devices listed nn back.
Circle all that apply:
NEPA 72. Chapter 1 2 -' : 6 7 and or IFC' SEC 907
NFPA 70. National Electrical Code. Article 760 Manufacturer's Instructions
\1anuFacturer's Instructions
Other (specif% )
Tukwila C it' Ordinance Numbers 2050. 2051
L'[.. Central Station !genitor A1a✓p►1 (t�u+.4cr stem is monitored bN
SIGNED Date
S� stem Firmware:
Installed %ersion Checksum
Initial program
Installation
Revisions and Reasons
Date
Date
Programmed tiv
PAGE 01/02
07/2/2015 09:47
3604384244
EQUIPMENT NSTALLED AND TESTED:
Control Panel
Manual Station
Smoke Detectors
Heat Detectors
Duct Detectors
A/V Devices
Audio Devices
Visual Device
Aute l.)oor Release
Trouble Indictors
Batteries
of
of
of
of
of
Readings Batter%
C.icnerator of
1IVAC' Controls of
Fire Alarm Dialer 1 of
Monitored byJpv."yvt
Annunciator
Make/Model
Make/Model
Make/Model
Make/Model
Make!Mode 1
Make/Model
Make/Model
Make/Model
MakelModel
Make/Model
Full Load
LACEY OPS PAGE 02/02
Make/Model
I\1 Ike/Model
Charge
_L Make/ModelAES — 77 ir
of Make!Model
Sprinkler System. (Fire Alarm
Water Flom S«. of
Vale Tamper Sw. of
PIV _ of
Elc . Alarm Bell ~^ of
connections only 1
Make 'Model
Makt'Mudel
Make'Model
Make!Mode1
Automatic time Dela. of Water Flow Alarm
seconds, None Installed
�)o you meet audible'%isihle requirements or WAC 51-20. IEC SEC 907,. and. Or ?FPA 72 Chapter 6"
Yes No
I opt or alarm S) stem on emcrgtnc\ power- satisfactory.' Yes No
Witnessed itnessedl b\. "Title
C onuncr ts:
Date
l=ire ,\Iurm CL!rtiticaic.duc
RAN iscd: 6:17 14 TED FP Firm a 110
Technical Specifications
7794
• Transmits full data to
AES-MultiNet receiver using
Contact ID or Pulse formats
Formats Supported: Contact
ID, Pulse 3+1, Pulse 4+1, Pulse
4+2, Modem Ile, and
Modem 111a2
I/O CONNECTIONS
• AES subscriber - data
and power
• Handheld/PC
programming port
• Plain Old Telephone Service
(POTS) incoming phone line
• Phone output connection
from alarm panel
• Trouble output (form C relay)
SIZE
• 4 7/8 in. x 5 in. (12.3 cm x 12.7
cm) Power Requirements
• 12 VDC nominal, primary and
backup power provided by the
AES RF Transceiver Unit
Current Consumption 350
mA nominal
7795
The 7795 AES-lntelliPro is a
kit that includes the 7794
module and 7762 Hardware
Supervisory module. *For model
7794, please see Technical
Specifications above
The 7762 is a Hardware
Supervisory Module.
I/O CONNECTIONS
• 31 - AES 7794 (J2) or Subscriber
(31)- data and power
• Input for Subscriber J4 Output
• Input for AES 7740 Local
Annunciator - data and power
• AES 7740/AES 7794 Trouble
Output to Subscriber
input zone
SIZE:
• 2 1/2 in. x 4 15/16 in.
(6.3 cm x 12.5 cm)
WEIGHT:
• 0.25 pounds (0.11 kilograms)
POWER INPUT:
• 12VDC nominal, power
supplied from AES 7794
module or AES
7744F/7788F Subscribers
CURRENT CONSUMPTION
• 40 mA average; 100 mA peak
Full Alarm Signal Data
No alarm data is lost converting fire alarm signals from over Public Switched
Telephone Network (PSTN) to transmission over AES-IntelliNet alarm communications.
AES lntelliPro Fire'e" Series modules transmit full alarm data captured off the FACP's digital
communicator including alarm zone identification and event codes. AES-IntelliPro Fire will
work in new fire alarm system installations to substitute phone line connections as well
as retrofit existing installed fire alarm systems. AES-lntelliPro Fire supports most alarm
communication protocols including Contact ID, Pulse, and Bosch Modem Ile and
Modem 111a2.
Flexible Installation Options
Existing installed Subscribers can easily be
upgraded to communicate full alarm data
from a FACP's digital dialer over AES-IntelliNet
networks. For these applications, models
7794 and 7795 are available as field installed
modules that come with all needed hardware
to upgrade an existing AES Subscriber. For
new installations, AES Fire Subscribers are
available equipped with the right AES-IntelliPro
Fire module for the application.
7794 AES-lntelliPro Fire Full Data Module. UL listed for supplemental
communication with fire radios
7795 AES-IntelliPro Fire Full Data Module (7794) with 7762 Hardware Supervisory
Module. UL listed for primary standalone communication with fire radios
7744F-ULP
7788F-ULP
7744F-ULP-P
7788F-ULP-P
7788F-C-ULP
4x4 Zone Fire Subscriber, 4 Reversing Polarity, 4 Supervised, includes
7794 AES-lntelliPro Fire, Red Enclosure
8 Zone Fire Subscriber, 8 Supervised Zones, includes 7794 AES-IntelliPro
Fire, Red Enclosure
4x4 Zone Fire Subscriber, 4 Reversing Polarity, 4 Supervised, includes
7795 AES-lntelliPro Fire, Red Enclosure
8 Zone Fire Subscriber, 8 Supervised Zones, includes 7795 AES-lntelliPro
Fire, Red Enclosure
8 Zone Fire Subscriber with 7794 AES-lntelliPro Fire, Red Enclosure
(ULC) Canada
7762 ' Add-on module provides power/supervision for 7794 AES-InteltiPro Fire
module and AES 7740 local trouble annunciator. Included with 7795
AES-lntelliPro Fire and AES 7742 local annunciator kit for Subscriber
Specifications Subject to Change Without Notice
USTED
us
I
NFPN
NetOne
ACCEPTED
p Without Comments
As Noted in Red
p Per The Attached Letter
These plans have been reviewed by The Tukwila Fire
prevention Bureau for conformance with current City
randards. Acceptance is subject to errors and
;missions which do not authorize violations of adopted
;andards and ordinances. The responsibility for the
adequacy of design rests totally with the designer.
Additions, deletions or revisions to these drawings after
this date will void this acceptance and will require a
resubmittal of revised drawings for subsequent approval.
Final acceptance Is subject to field test and inspection by
The Tukwila Flre Prevention Bureau.
Date:
7-1 t�'
eiNivi& 5$..414 k+. 4So c. A -ES aid 0-.644;6,0
Gtvt.,.; F- w/ 6yrak— 11441/ clgw.ro -
NOTICE
A completed, signed, Tukwila
Fire Department Pre-test
Certificate must be presented
to the Inspector prior to
commencement of Acceptance
Testinc§ of any Fire Alarm
and C),. ,,,cion Systems.
Failure of test will result
in a Re -inspection Fee and
4-prrnination of the testing
KWILA i"RE DEPARTMENT
call 206-575-4407 and
jsS thiS Fire
o No.
„Ind exact add ss for shut-
down or restoration approval.