Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PP - 12646 INTERURBAN AVE S - GATEWAY CORPORATE CENTER BUILDING #3 - PERMITS AND PLANS
12646 INTERURBAN AVE S ASSOCIATED PERMITS 13-F-201 13-5-194 96-S-261 From: Cascade Alarm, LLC To: 2065754439 Page: 2/2 Date: 8/27/2013 11:32:34 PM Cascade Alarm PO BOX 7459 - KENT, WASHINGTON 98042 - 206-767-5800 ext.#2 - FAX: 253-630-4851 August 27, 2013 Battalion Chief Tomaso Tukwila Fire Department 444 Andover Park Tukwila, WA 98188 RE: TMCS 12646 Interurban Ave, Gateway Corporate Bldg. #3 Tukwila, WA 98188 Don, TUKWILA FIRE DEPARTMENT Please cal! 206-575-4407 and give this Fire Permit No. /3 - S- J9L and exact address for shut- down or restoration approval. I know you guys are busy and a left you a message earlier. My question is: Could you please issue us a shutdown number so we can plug 7 drops. The tenant is removing the ceiling grid and it is going back to just the warehouse space as it was before with the existing uprights above for adequate coverage. Please let me know. Sincerely, CASCADE ALARM (FIRE PROTECTION DIVISION) Roxanne Craine Service & Inspections *SECURITY & FIRE ALARM SYSTEMS - FIRE PROTECTION SYSTEMS - UL CENTRAL STATION MONITORING - CONFIDENCE TESTING * *24 HOUR SERVICE - LICENSED, BONDED, INSURED * "First When Seconds Count" ** Security, Fire Sprinkler & Fire Alarm Systems, 24/7 Service, Local UL Listed Central Station Monitoring, Certified Inspections & Extinguishers ** EA C Fl E &SECU WWW. sir 3yelectric.co IT STE p Without Comments As r&A:etd in Red 0 Per The Attached Letter se plans gave been revk weed by The Tukwila Fire tiiiort Buri izu for catformitince with current City ;cards. Acceptance is S,Joj c. to errors and ;.srsionS which co not tut,hOri: c violaUonS of adopted :,curds and eillirlaNait5. The responsibility for the • :ivacy of desigt, te.!:Tits totally w i i the designer, ,1onsE del do or r� 'i signs to trt,��.. drawings after s date; wlil voEc tip; cceptGfl ifnd ��i'l require a resubmittal of revised drewin9s for subsequent approval. Final acceptDnce is subject to field test and inspection by The Tukwiia Hue i"revention Bureau. Date: �� ' ..�. - - By th.ss:C- ( bYYgi< v 1'4 tl{ c.k1i° otiGiedicA3 PS G,YG...4 y✓c t -e . x s �,ok( d.a. as.r� P s TUKWILA FIRE DEPARTMcEI`ff Please call 206-575-4107 and give this Fire Permit No. _ao' andI� exactFaddress for shut- down hutdown or restoration approval. NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems, Failure of test will result in a.Re-inspection. Fee and termination of the testing JOB CONTACTS GENERAL PROJECT INFORMATION PAUL HOSKINS PAULH©KIRBYELECTRIC.COM DRAWING/DESIGN INFORMATION MAX POPKOV MAXP©KIRBYELECTRIC.COM TECHNICIAN SCHEDULING PAUL HOSKINS PAULH©KIRBYELECTRIC.COM STE p Without Comments As r&A:etd in Red 0 Per The Attached Letter se plans gave been revk weed by The Tukwila Fire tiiiort Buri izu for catformitince with current City ;cards. Acceptance is S,Joj c. to errors and ;.srsionS which co not tut,hOri: c violaUonS of adopted :,curds and eillirlaNait5. The responsibility for the • :ivacy of desigt, te.!:Tits totally w i i the designer, ,1onsE del do or r� 'i signs to trt,��.. drawings after s date; wlil voEc tip; cceptGfl ifnd ��i'l require a resubmittal of revised drewin9s for subsequent approval. Final acceptDnce is subject to field test and inspection by The Tukwiia Hue i"revention Bureau. Date: �� ' ..�. - - By th.ss:C- ( bYYgi< v 1'4 tl{ c.k1i° otiGiedicA3 PS G,YG...4 y✓c t -e . x s �,ok( d.a. as.r� P s TUKWILA FIRE DEPARTMcEI`ff Please call 206-575-4107 and give this Fire Permit No. _ao' andI� exactFaddress for shut- down hutdown or restoration approval. NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems, Failure of test will result in a.Re-inspection. Fee and termination of the testing 12646 INTERURBAN AVE S 13-F-201 KIRBY FIRE & SECURITY www.kirbyelectric.com 4826 "B" St. NW Suite 101 Auburn, Washington 98001 (253) 859-2000 (FAX) 859-2363 TCMS GATEWAY CORP. CENTER BUILDING 3 12646 INTERURBAN AVE S TUKWILA, WA 98168 REVISIONS: PAID AUG 22 2013 TUKWILA FIRE SCALE: N.T.S. DATE: 8-22-13 DRAWN BY: MP CHECKED BY: SHEET FA JOB NO.: OF SHEET INDEX PAGE: DESCRIPTION FA TITLE SHEET FA1 COVER SHEET FA2 FIRE ALARM PLAN 12646 INTERURBAN AVE S 13-F-201 KIRBY FIRE & SECURITY www.kirbyelectric.com 4826 "B" St. NW Suite 101 Auburn, Washington 98001 (253) 859-2000 (FAX) 859-2363 TCMS GATEWAY CORP. CENTER BUILDING 3 12646 INTERURBAN AVE S TUKWILA, WA 98168 REVISIONS: PAID AUG 22 2013 TUKWILA FIRE SCALE: N.T.S. DATE: 8-22-13 DRAWN BY: MP CHECKED BY: SHEET FA JOB NO.: OF SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: Z 7 1 6. elf 003m Site Address: / 2.( LI O'4TEQ tA.28A N AJ€ S, Suite Number: Tenant Name: S Property Owner's Name: Floor: New Tenant? 1 - Yes ❑ - No GliprEusA Y Cole(' 1 E,JTEla : 3 Mailing Address: PC 30X 4/ 900 CONTACT PERSON -if there are questions about the submittal. Name: J HAWN L-Er4 MAN V 123 Y Etc... -e,c_ Company Name: 5orrs A2 X524 1 City State Zip Day Telephone: 2:53-2S59 Mailing Address: Lig Zio 'L ff Au 8u A 154150 I '' City S to Zip E-mail Address: 514A 6* 6 I4I2B?EL .TSG . COW-- Fax Number: 3 " 9 - Z3 43 Total number of new/relocated devices or sprinkler heads: �y Valuation of Project (contractor's bid price): $ 4' 173. 00 Scope of Work (please provide detailed information): Ab A F E /jails, tATtc a %Ev e CES PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED ENT: Signature: 1 v1eR,f,4/1- Print Name: 5►4a►0 N L EPIMS& $J Plan Permit App.doc 1/2/13 2.3"3-e59- Date: 9' - 22--13 Day Telephone: 2454:54 X 3I Z TFD FP Form 8 GENERAL NOTES 1. FIRE ALARM SYSTEM IS POWER LIMITED. METALLIC RACEWAY SHALL BE USED IF REQUIRED BY CODE OR SPECIFICATIONS AND CONTRACT DOCUMENTS. 2. ALL RACEWAYS MUST BE FREE OF MOISTURE 3. REFER TO DATA SHEETS FOR PROPER TYPE AND SIZES OF REQUIRED DEVICE DEVICE MOUNTING ELECTRICAL BOXES. 4. AC VOLTAGE IS NOT PERMITTED IN THE SAME RACEWAY AS FIRE ALARM WIRING 5. UNRELATED (NON FIRE ALARM) WIRE SHALL NOT BE IN THE SAME RACEWAY AS FIRE ALARM WIRE 6. ALL CONTRACTOR FIELD WIRING MUST ENTER ALARM CONTROL PANEL BACKBOX FOLLOWING POWER -LIMITING AND NON POWER -LIMITING WIRING REQUIREMENTS. REFER TO INSTALLATION INSTRUCTIONS FOR MORE INFORMATION. 7. ZONE CIRCUITS AND SIGNAL CIRCUITS ARE ELECTRICALLY SUPERVISED. BRANCH CIRCUITS SHALL BE LOOPED TO MAINTAIN INTEGRITY OF SUPERVISED CIRCUITS. T -TAPPING OF ZONE AND SIGNAL CIRCUITS IS NOT PERMITTED. 8. REFER TO FACP MODULE DIAGRAMS, INCLUDED WITH FACP, FOR SPECIFICATIONS AND INFORMATION ON INDIVIDUAL PANEL MODULES. 9. ALL FIRE ALARM WIRING SHALL TEST FREE OF OPENS, SHORTS, AND GROUNDS. 10. ALL WIRING SHALL BE LABELED AND TAGGED. 11. ALL WIRING SHALL MEET ALL APPLICABLE NATIONAL ELECTRIC CODE ARTICLES FOR FIRE ALARM AND LOW -VOLTAGE WIRING. 12. DO NOT USE FIRE ALARM CABINET AS TERMINAL CABINET ARCHITECT: DAVID KEHLE ARCHITECT SEATTLE, WA FIRE ALARM SYSTEM DESIGNED BY: KIRBY ELECTRIC INC. AUBURN, WA FIRE ALARM SYSTEM INSTALLED BY: KIRBY ELECTRIC INC. AUBURN, WA EQUIP. FOR FIRE ALARM SYSTEM SUPPLIED BY: SILENT KNIGHT INC. NORTH FORD, CT WA STATE ELECTRICAL CONTRACTORS NUMBER: KIRBYEIO77BN * THESE DRAWINGS DO NOT SUPERSEDE THE CONTRACT DRAWINGS AND SPECIFICATIONS, THEY ARE INTENDED AS A SUPPLEMENT ONLY AND MUST BE USED IN CONJUNCTION WITH THE CONTRACT DOCUMENTS. THEY DO NOT MODIFY THE CONTRACTORS OBLIGATIONS TO CONFORM TO THE PROJECTS ORIGINAL DESIGN CRITERIA A B C D E NOTES: 1 SMOKE DETECTOR 8 2 PULL STATION 3 WATER FLOW 4 TAMPERS 5 Ply 6 DUCT DETECTOR • A B C D E FIRE ALARM SYSTEM MATRIX SCALE: N.T.S. MOUNTING HEIGHTS CEILING r/7///////7/7///, 7/// SYNCHRONIZED MORE THAN TWO VISUAL APPUANCES IN ANY FIELD OF VIEW. A/C SUPPLY DI FUSER 3' (MIN) CEILING MOUNTED AUDIO/VISUAL SMOKE/HEAT & VISUAL ONLY DETECTOR DEVICES 80" MIN 96" MAX FACP 66" AFF FINISHED FLOOR RT7772.1Z% ///! • DEVICES SHOWN DEPICT DEVICE TYPES ONLY. MAGNETIC DOOR HOLDER 101 11 Q FLUORESCENT LIGHT l//////////// / 7 NOTE: DIMENSIONS SHOWN ARE TO THE CLOSEST EDGE OF THE DETECTOR 3' PERMITTED ) NOT PEFMITTED HERE HERE DOOR -+- WIDTH LESS 3" PERMITTED HERE 6" - FIRE MANUAL PHONE PULL JACK STATION 48" MAX (ADA) 42"MIN/54" MAX (NEPA) 2" AX iz // ///!////////!!/////!///.M FIRE ALARM LEGEND SYMBOL DESCRIPTION DESCRIPTION 0.000 0.066 FACP 12 GAUGE 2 CONDUCTOR (NAC) FIRE ALARM CONTROL PANEL 16 GAUGE 2 CONDUCTOR (SLC) C 16 GAUGE 4 CONDUCTOR (S BUS) D FAA FIRE ALARM ANNUNCIATOR System Sensor P2/PC2 Horn/Strobe (30cd) Prepared By:IMP I Dera ing Factor: P.S. POWER SUPPLY PIV POST INDICATOR VALVE F FIRE ALARM MANUAL PULL STATION Threshold %10 FIRE ALARM HORN/STROBE # INDICATES CANDELA RATING Panel ID: PS Model: 5495 Power Expander Max NAC Current: 3.0 Amps BS Ckt.# Circuit Name Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ %Drop S andby Alarm & Type 1000 Ft. One -Way Ohms EOL BEAM SMOKE DETECTOR 5495 Pwr Module I 1 BR 0.205 BEAM REFLECTOR IE MINI -HORN .e ♦ WALL MNT. FIRE ALARM STROBE ONLY # INDICATES CANDELA RATING NP ♦ CEILING MNT. FIRE ALARM STROBE ONLY # INDICATES CANDELA RATING DF DRY FLOW SWITCH Eg WATER FLOW SWITCH HL HIGH/LOW AIR T TAMPER SWITCH CE DRY TAMPER SWITCH R RELAY OSMOKE DETECTOR OSB SMOKE DETECTOR W/ SOUNDER BASE OR SMOKE DETECTOR W/ RELAY BASE OHEAT DETECTOR ;O SPEAKER STROBE # INDICATES CANDELA RATING DS DUCT SMOKE DETECTOR SR SPRINKLER RISER B EXTERIOR BELL WB WATER BELL M MONITOR MODULE -NW 4.71d2 OF LINE RESISTOR (E) EXISTING (R) RELOCATED NOTE: NOT ALL SYMBOLS ARE USED IN THESE DRAWINGS #12 Solid GENERAL NOTES 1. FIRE ALARM SYSTEM IS POWER LIMITED. METALLIC RACEWAY SHALL BE USED IF REQUIRED BY CODE OR SPECIFICATIONS AND CONTRACT DOCUMENTS. 2. ALL RACEWAYS MUST BE FREE OF MOISTURE 3. REFER TO DATA SHEETS FOR PROPER TYPE AND SIZES OF REQUIRED DEVICE DEVICE MOUNTING ELECTRICAL BOXES. 4. AC VOLTAGE IS NOT PERMITTED IN THE SAME RACEWAY AS FIRE ALARM WIRING 5. UNRELATED (NON FIRE ALARM) WIRE SHALL NOT BE IN THE SAME RACEWAY AS FIRE ALARM WIRE 6. ALL CONTRACTOR FIELD WIRING MUST ENTER ALARM CONTROL PANEL BACKBOX FOLLOWING POWER -LIMITING AND NON POWER -LIMITING WIRING REQUIREMENTS. REFER TO INSTALLATION INSTRUCTIONS FOR MORE INFORMATION. 7. ZONE CIRCUITS AND SIGNAL CIRCUITS ARE ELECTRICALLY SUPERVISED. BRANCH CIRCUITS SHALL BE LOOPED TO MAINTAIN INTEGRITY OF SUPERVISED CIRCUITS. T -TAPPING OF ZONE AND SIGNAL CIRCUITS IS NOT PERMITTED. 8. REFER TO FACP MODULE DIAGRAMS, INCLUDED WITH FACP, FOR SPECIFICATIONS AND INFORMATION ON INDIVIDUAL PANEL MODULES. 9. ALL FIRE ALARM WIRING SHALL TEST FREE OF OPENS, SHORTS, AND GROUNDS. 10. ALL WIRING SHALL BE LABELED AND TAGGED. 11. ALL WIRING SHALL MEET ALL APPLICABLE NATIONAL ELECTRIC CODE ARTICLES FOR FIRE ALARM AND LOW -VOLTAGE WIRING. 12. DO NOT USE FIRE ALARM CABINET AS TERMINAL CABINET ARCHITECT: DAVID KEHLE ARCHITECT SEATTLE, WA FIRE ALARM SYSTEM DESIGNED BY: KIRBY ELECTRIC INC. AUBURN, WA FIRE ALARM SYSTEM INSTALLED BY: KIRBY ELECTRIC INC. AUBURN, WA EQUIP. FOR FIRE ALARM SYSTEM SUPPLIED BY: SILENT KNIGHT INC. NORTH FORD, CT WA STATE ELECTRICAL CONTRACTORS NUMBER: KIRBYEIO77BN * THESE DRAWINGS DO NOT SUPERSEDE THE CONTRACT DRAWINGS AND SPECIFICATIONS, THEY ARE INTENDED AS A SUPPLEMENT ONLY AND MUST BE USED IN CONJUNCTION WITH THE CONTRACT DOCUMENTS. THEY DO NOT MODIFY THE CONTRACTORS OBLIGATIONS TO CONFORM TO THE PROJECTS ORIGINAL DESIGN CRITERIA A B C D E NOTES: 1 SMOKE DETECTOR 8 2 PULL STATION 3 WATER FLOW 4 TAMPERS 5 Ply 6 DUCT DETECTOR • A B C D E FIRE ALARM SYSTEM MATRIX SCALE: N.T.S. MOUNTING HEIGHTS CEILING r/7///////7/7///, 7/// SYNCHRONIZED MORE THAN TWO VISUAL APPUANCES IN ANY FIELD OF VIEW. A/C SUPPLY DI FUSER 3' (MIN) CEILING MOUNTED AUDIO/VISUAL SMOKE/HEAT & VISUAL ONLY DETECTOR DEVICES 80" MIN 96" MAX FACP 66" AFF FINISHED FLOOR RT7772.1Z% ///! • DEVICES SHOWN DEPICT DEVICE TYPES ONLY. MAGNETIC DOOR HOLDER 101 11 Q FLUORESCENT LIGHT l//////////// / 7 NOTE: DIMENSIONS SHOWN ARE TO THE CLOSEST EDGE OF THE DETECTOR 3' PERMITTED ) NOT PEFMITTED HERE HERE DOOR -+- WIDTH LESS 3" PERMITTED HERE 6" - FIRE MANUAL PHONE PULL JACK STATION 48" MAX (ADA) 42"MIN/54" MAX (NEPA) 2" AX iz // ///!////////!!/////!///.M PROJECT NOTES 1. . RJ31 X TELCO 120VAC FIRE ALARM RISER SCALE: N.T.S. WIRING LEGEND Device Current Draw Each Current Draw Total Standby Alarm Standby ' Alarm SYMBOL DESCRIPTION 0.000 0.066 A 12 GAUGE 2 CONDUCTOR (NAC) B 16 GAUGE 2 CONDUCTOR (SLC) C 16 GAUGE 4 CONDUCTOR (S BUS) D 14 GAUGE SHIELDED 2 COND. (SPEAKER) 2 PROJECT NOTES 1. . RJ31 X TELCO 120VAC FIRE ALARM RISER SCALE: N.T.S. [Project Name: TOMS Prepared By: MP Project Information Project ID: 0 Date: 8/22/136 Ckt. Number: NAC #1 Panel ID: PS Ckt. Name: 5495 Circuit 1 Max Circuit Current: 3 Amps .� Device Current Draw Each Current Draw Total Standby Alarm Standby ' Alarm 8 System Sensor S/SC Strobe (15cd) 0.000 0.066 Si , 4, Nz` �, " � j3 t r Project Name:ITCMS I Standby Hours: 24 ' 2 System Sensor P2/PC2 Horn/Strobe (15cd) KNI(..; '� j i: Project ID:) Alarm Mins:I 5 t 0.182 2 System Sensor P2/PC2 Horn/Strobe (30cd) Prepared By:IMP I Dera ing Factor: 0.116 1.2 t�k.€,ti4��i' 5495 Power Expander Calculations !; Date: 8/22/136 Voltage Drop Warning Version 02.1809 x i �1' Threshold %10 0.000 Panel ID: PS Model: 5495 Power Expander Max NAC Current: 3.0 Amps Location: I Volts: 24 VDC Max Panel Current: 6.0 Amps Ckt.# Circuit Name Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ %Drop S andby Alarm & Type 1000 Ft. One -Way Ohms EOL 5495 5495 Pwr Module I 1 0.075 0.205 Totals NAC #1 " 5495 Circuit 1 0.000 1.294 #12 Solid 1.59 350 1.1 t 18.96 7.06% NAC #2 ' 5495 Circuit 2 0.000 0.000 #12 Solid 1.59 0.00 20.40 0.00% NAC #3 5495 Circuit 3 0.000 0.000 #12 Solid 1.59 0.00 20.40 0.00% NAC #4 5495 Circuit 4 0.000 0.000 #12 Solid 1.59 0.00 20.40 0.00% Aux 5495 Aux Power Out 0.000 0.000 #12 Solid 1.59 0.00 20.40 0.00% Total Standby Current (Amps) 0.075 1.499 Total Alarm Current (Amps) Standby Time In Hours 24 0.083 Alarm Time In Minutes / 60 (5 Mins) Total Standby AH Required 1.800 0,125 Total Alarm AH Required Total Combined AH Required 1.92 Wire resistances are based upon an ambient temperature of 72 degrees F. Because of the minimal difference between solid and stranded wire no differential was made. Multiply By The Derating Factor 1.20 Minimum Battery AmpHours Required 2.31 [Project Name: TOMS Prepared By: MP Project Information Project ID: 0 Date: 8/22/136 Ckt. Number: NAC #1 Panel ID: PS Ckt. Name: 5495 Circuit 1 Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby ' Alarm 8 System Sensor S/SC Strobe (15cd) 0.000 0.066 0.000 ; 0.528 2 System Sensor P2/PC2 Horn/Strobe (15cd) 0.000 0.091 0.000 t 0.182 2 System Sensor P2/PC2 Horn/Strobe (30cd) 0.000 0.116 0.000 '; 0.232 2 System Sensor P2/PC2 Horn/Strobe (75cd) 0.000 0.176 0.000 0.352 0:000 0.000 1 0.000 Totals 0.000 1.294 Ckt. Number: NAC #2 Panel ID: PS Ckt. Name: 5495 Circuit 2 Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby , Alarm Unused 0.000 0.000' 0.000 ' 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 <:0.000 0:000 0.000 Totals 0.000 0.000 KIRBY FIRE & SECURITY www.kirbyelectric.com 4826 "B" St. NW Suite 101 Auburn, Washington 98001 (253) 859-2000 (FAX) 859-2363 TCMS GATEWAY CORP. CENTER BUILDING 3 12646 INTERURBAN AVE S TUKWILA, WA 98168 REVISIONS: SCALE: N.T.S. DATE: 8-22-13 DRAWN BY:MP CHECKED BY: SHEET FA1 JOB NO.: OF 174: -o% -k1 �atis a�- A TO NAC AT FACP — — — — -�-- EXIT 1 1—IALL1 NEUJ WAREHOUSE 18 NEEUJ TRAINING ROOM 1 �1 1 OFF IfCE (—A OFFCE 14 DISP. 2 RECFT 5 15 OFFICE FIRE ALARM PLAN OFFICE S OFFICE SCALE: 1/8"=l'—O" 1 mar FIRE & SECURITY www.kirbyelectric.com 4826 "B" St. NW Suite 101 Auburn, Washington 98001 (253) 859-2000 (FAX) 859-2363 TCMS GATEWAY CORP. CENTER BUILDING 3 12646 INTERURBAN AVE S TUKWILA, WA 98168 REVISIONS: SCALE: 1 /8"=1,-0" DATE: 8-22-13 DRAWN BY:MP CHECKED BY: SHEET FA2 JOB NO.: OF SGD P6 b1 ‘4412., PATR. Io'r FWZE -r0 6xrevi;" CXi rti1 SG�'I'°} „iir sys> (AA. -rb Pk0V1DC spk 0)4 L4 k, PA-ree°oro Al ON Iperze'_ NEW fit r2-tA voidr'_ z"K1o' aoms-rs MEZZANINE PLAN I/4"= I,_ O„ ExTE'ZI C!Z. WA C.C. No -re -5 ARCA Q. 4A7E14/A y /.Vp PARK - (SovTW) ACCEPTED j WITHOUT COMMENTS. ❑ A3 NOTED IN RED ❑ PER THE ATTACHED LETTER The drawings affixed hereto have been reviewed and accepted by the City of Tukwila Fire Dept. Aiditions, deletions or revisions to th 'r3wings after this date will void thi:i _ .:aptance and will require a resubmittal of revised drawings. Final acceptance is subject to field- inspection by a representative of this department DATE: _ 2`ilLBY: ,4--I 5�t( CITY OF TUKWILA 575.4407 /N-Tede iJ2 SAN SITE PLAN AVE 5 (f9d th . IlV,/ /41 TUKWILA FIRE DEPART Please call.: 575-4407 and give this job No. r -s - NTS and exact address for shut down or restoration approval. ALL NA/VG..Ees - -r6 cc - Ere-- LEY a e GS RdD 2. HD c,s1AR S -ro 14' 11157%.C.C.0 ort SD774 weADS 3. S-rE,tt. DESr4NCA P'exe. µt T=A pIPe SCNEDV 12646 INTERURBAN AVE S 96-S-261 NEL�A--_-.__13.. 01211. • T771 OCT 2 4 '1996 a I SPRINKLERS USED SYM SPRINKLER ORIFICE SIZE. TYPE & FINISH QUAN TEMP -B REL1AI3LE 4, 55P- _,Rizz I/V1 Z 146 REVISIONS MK DATE BY A A CONTRACT NAME: PHO E N I X TECHNOLOGIES 12646 INTERURBAN AVE S TUKWILA/ -WA NEW MEZZANINE I IATRuoT • FIRE PROTECTION 2004-A 48th Ave Ct. E. Tacoma, WA 98424 (Phone) 926-2290 (Fax) 922--6150 DESIGNER I DATE I SHEET I JOB NO. 14z/4 P404i 10/zz./4 6 I I OF I 12.3039 i Kyle, 90 40, r EPUC.E VIC &EXIST, NIACIN W 8`x ¢i�C�RV. h4DOLE P R ILL.ETJ IN P. EXIST ELEV. + i�' Q EXIST rISE R glow t Tei 0 2-10 -1 YA.L OPENINCT ti FRONT viEV'/ SIDE v►E.J -}OSE G I I N E:T NTS. All com various strued has be jury or, result 1 JUN 1 As meeting requirements et tam IiiiieiliA US however, system changes or additio ss nom sheets) will result in improved submitted sad for construction and vagancy $" kistlation subieet to iiispection t ar..a..va• elate exclusiy ents and acceptances r onditions upon fire insurance rates bearing in any way upon the qu ti exercised with respect to po bl amage to property. It is recti loss still exist. 7 i I tq tela af U d ar o rare-notwhether "du care" e �ity 1orQer nal in- �rds whi h may �.1. 11111111 G E'EKA L I) PIPE SIZES PER NFP& -I oRp NARY 4AZAR7 IFE E�LIL t o 5•F• MAK, PER SF INK u M�_i��jj II}}b Z'o -x1. - PURLI w �'1 E E got)f Ri C� A-TTAGFfED Wt I-} !zx i PER I PA -. 4c.9406,) 17) ALL r� A TNR S ; � 5LKTo 4.)04 IW>"f R xz� 11. s 51 A-13 . Cw�)(+�+) aal L4tN`e TA: pll1��Tt) a 1t F. 4c . S-> - HF_ Joi 5YY-r Rr F►T11 4--t FLEX rojW. +-F RIGID Rlloilr' b•lRV 4-7 2- WA`( E _ct waY A _ 1U.PNPt+ F'DR 7) F-Rar pit OF WALL- Pbft REFLECIED CEIL Off-. Pelt TUKWILA FIRE DEPARTMENT" PleaSe call: 575.4407 end give this Job No, a 0/33 tirtd exact address f rrsh down or restoration approval HYDRAULIC INFORMATION RESIDUAL P.S.I. THIS SYSTEM DESIGNED G.P.M. OVER THE HYDRA SQ. FT. WHEN SUP ATARATEO D WITH WATER A E BASE OF RISER G.P.M. AT E HOSE INSIDE HOSE P S.I. RACK SPR GENERAL NOTES 1) INSTALLATION TO CONFORM Tq N.F.P.A. # I� AND C.I TI/ OF TUKWR k `t W. S • RI. S. 2) ALL MATERIALS NEW AND U. t_ • APPROVED. 3) ALL WELDING PERFORMED IN SHOP AND IN ACCORD- ANCE WITH A.W.S. D-10.9. 4) PAINTING OF PIPE NOT 1N CONTRACT. 5) ELECTRICAL WIRING NOT IN CONTRACT. 6) EARTHQUAKE BRACING PER CODE. 7) USE FIG. # 401 POLISHED ALUM. CANOPY, U.N.O. #1 #2 #3 #4 #5 #6 #7 #8 #9 HANGER LEGEND - EXP. SHELL, ROD & RING - C -CLAMP, ROD & RING - POWDER STUD, ROD & RING - ANGLE CLIP, ROD & RING - L -ROD & RING - EYEROD & RING - COACH SCREW, ROD & RING - CEIL. FLG., ROD & RING -UHOOK SPRINKLER HEAD SYMBOLS O - UPRIGHT ON LINE - • UPRIGHT ON 1" SPRIG UP ® - PENDENT ON LINE 0 - PENDENT ON 1" DROP - UPRIGHT & PENDENT DROP - • UPRIGHT SPRIG & PENDENT DROP -SIDEWALL ® - DRY SIDEWALL - • DRY PENDENT DROP ALARM:• -r SPRINKLERS CENTRAL*14° REVISIONS ORIF. TYPE IEC,E412 ROO DEGREE I (p5" FINISH G4-1.rori E QTY 48 NORTH ACCEPTED ❑ WITHOUT COMMENTS. '❑ AS NOTED IN RED F 2R THE ATTACHED LETTER The drawings affixed hereto have been reviewed and accepted by the City of Tuk'.vil3 Fire Dept. Aiditions, deletions or revisions to tree -drawings after this date will void this a .cedt-An, e and will require a resubn-:itt,.;I of revised drawings. Final acceptance is subject to field - inspection by a representative of this department DATE:.2 IA) BY: F74-41I)<TES-} 12.1.a -C.0 INTI=121J+zE TUI<w►L- , \A/4s-1-1 0411-oN TRIANGLE FIRE PROTECTION TOTAL SPRINKLERS 12646 INTERURBAN AVE S 90-S-133 11 1 P.O. BOX 264 WOODINVILLE, WA 98072 527-5211 483-5211 CONTRACT WITH: l26 . GO P WA. STATE CONT. LIC. NO. TR - IA - NF - P2740P SCALE: 5 . (I Qu BY: G .•itn,Zz. DATE C> - `90 JOB #: fJW- 2.17Z 'I OF 1 THE COMPLETE LINE/ 135682 90-s/3.3 WASHINGTON SURVEYING AND RATING BUREAU 300 MARKET PLACE ONE 2001 WESTERN AVENUE SEATTLE, WASHINGTON 98121-2190 June 12, 1990 PLAN SHEET 1 OF 1 SUBJECT Phoenix Tech, Tenant Improvement Gateway Phase IV, Building 3 12646 Interurban Avenue South Tukwila, Washington The attached plans have been Accepted as meeting requirements for classification as a sprinklered risk. The following revisions or additions to the design as shown would qualify the protection for improved rates based upon information shown on these plans: Arrangements should be made to allow a representative of this Bureau to complete a cover inspection of all piping before it is concealed by building construction, and to witness tests of the local water motor alarm and sprinkler supply test pipe. Completed copies of the Contractor's Material and Test Certificates for both the overhead and underground piping should be submitted to this Bureau. All piping, valves, and fittings should be listed and labeled by UL for fire service and installed, tested, and flushed in accordance with NFPA standards. Wet pipe sprinkler equipment is acceptable subject to provision of a thermostatically controlled heating system capable of maintaining temperatures at not Tess than 40 degrees F in all spaces containing wet pipe sprinkler equipment. 1. Acceptance is subject to revision of pipe sizes as noted in red pencil on plans. Pipe sizes shall be in accordance with Table 8-3.2 (a) of NFPA 13 (1989). 2. Replace existing 165 degree F sprinklers in blind roof space with 212 degree F sprinklers. 3. Inside hose stations should be supplied independent of overhead sprinkler piping. ACCEPTED dY 11AS U Gts N SMS & RAMS 1OAEAU City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188-7661 (206) 575-4404 Gary L. VanDusen, Mayor June 19, 1990 Fire Department Review Re: Phoenix Technology - 12646 Interurban Avenue South Dear Sir: -The-attached-set of sprinkler plans have been reviewed by The Tukwila Fire Prevention Bureau and are acceptable with the following concerns: 1. Upsize feeder main to 3 1/2" as indicated by W.S.R.B. 2. All new overhead piping shall be hydrostatically tested. Test pressure shall be not less than 200 psi for 2 hours. 3. There shall be maintained on the premises a supply of spare sprinklers (never less than 6) so that any sprinklers that have operated or been damaged in any way may promptly be replaced. (NFPA 13, 3-16.7.1) (UFC 10.302) Local U.L. Central Station Supervision is required. (UFC 14.105) Contact the Tukwila Fire Department, Fire Prevention Bureau to witness all required inspections and tests. (NFPA 13, 1-10.2) (UFC 10.305(b)) Yours truly, The Tukwila Fire Prevention Bureau cc: T.F.D. file ncd